Contents & Storage

Illumina-Supplied Consumables

Item

Quantity

Storage

MA2

2 tubes (per 96 samples)

-15° to -25°C

MA1

2 tubes (per 96 samples)

-15° to -25°C

TEM

2 tubes (per 8 BeadChips)

-15° to -25°C

MSM

2 tubes (per 96 samples)

-15° to -25°C

RA1

46 µl per sample well

-15° to -25°C

RA1

10 ml for 1–8 BeadChips; 20 ml for 9–16 BeadChips; 30 ml for 17–24 BeadChips

-15° to -25°C

STM (Make sure that all STM tubes indicate the same stain temperature on the label)

2 tubes (per 8 BeadChips)

-15° to -25°C

FMS

2 tubes (per 96 samples)

-15° to -25°C

XC1

2 tubes (per 8 BeadChips)

-15° to -25°C

XC2

2 tubes (per 8 BeadChips)

-15° to -25°C

ATM

2 tubes (per 8 BeadChips)

-15° to -25°C

PM1

2 tubes (per 96 samples)

2° to 8°C

Wash Rack

1 (up to 8 BeadChips)

Room temperature

Wash Dish

2 (up to 8 BeadChips)

Room temperature

XC4

310 ml for 1–8 BeadChips; 285 ml for 16– 24 BeadChips

Room temperature

Te-Flow Flow-Through Chambers (with black frames, spacers, glass back plates, and clamps)

1 (per BeadChip)

Room temperature

XC3

50 ml for 1–8 BeadChips; 100 ml for 9–16 BeadChips;150 ml for 17–24 BeadChips

Room temperature

PB2

4x3 or 4x1 HD BeadChip: 3 tubes (per 48 Samples)

 

Room temperature

Hyb Chamber gaskets

4x3 or 4x1 HD BeadChip: 3 (per 48 Samples)

Room temperature

Hyb Chamber inserts

4x3 or 4x1 HD BeadChip: 12 (per 48 Samples)

Room temperature

Hyb Chamber inserts

8x1 HD BeadChip: 12 (per 96 Samples)

Room temperature

BeadChips

4x3 or 4x1 HD BeadChip: 12 (per 48 Samples)

Room temperature

BeadChips

8x1 HD BeadChip: 12 (per 96 Samples)

Room temperature

Hyb Chamber gaskets

8x1 HD BeadChip: 3 (per 96 Samples)

Room temperature

PB1

550 ml (up to 8 BeadChips)

Room temperature

PB1

310 ml for 1–8 BeadChips; 285 ml for 9–24 BeadChips

Room temperature

PB2

8x1 HD BeadChip: 2 tubes (per 96 Samples)

Room temperature

Hyb Chambers

8x1 HD BeadChip: 3 (per 96 Samples)

Room temperature

Hyb Chambers

4x3 or 4x1 HD BeadChip: 3 (per 48 Samples)

Room temperature

Multi-Sample BeadChip Alignment Fixture

1 (per 8 BeadChips)

Room temperature

User-Supplied Consumables

Item

Quantity

Storage

95% formamide/1 mM EDTA

15 ml for 1–8 BeadChips; 17 ml for 9–16 BeadChips; 25 ml for 17–24 BeadChips

-15° to -25°C

WG#-DNA plate with 96 DNA samples (50 ng/µl)

1 plate

-15° to -25°C

96-well 0.8 ml microtiter plate (MIDI)

1 plate

 

Lambda DNA

See Instructions

2° to 8°C

PicoGreen dsDNA quantitation reagent

See Instructions

2° to 8°C

0.1N NaOH

15 ml (per 96 samples)

2° to 8°C

96-well 0.65 ml microtiter plate

1 per 96 samples

Room temperature

1X TE (10 mM Tris-HCl pH8.0, 1 mM EDTA (TE))

See Instructions

Room temperature

100% 2-propanol

40 ml (per 96 samples)

Room temperature

Alconox Powder Detergent

as needed

Room temperature

EtOH

as needed

Room temperature

Fluotrac 200 96-well flat-bottom plate

1 per Std DNA plate

1 per Sample DNA plate

Room temperature