Item | Quantity | Storage |
MA2 | 2 tubes (per 96 samples) | -15° to -25°C |
MA1 | 2 tubes (per 96 samples) | -15° to -25°C |
TEM | 2 tubes (per 8 BeadChips) | -15° to -25°C |
MSM | 2 tubes (per 96 samples) | -15° to -25°C |
RA1 | 46 µl per sample well | -15° to -25°C |
RA1 | 10 ml for 1–8 BeadChips; 20 ml for 9–16 BeadChips; 30 ml for 17–24 BeadChips | -15° to -25°C |
STM (Make sure that all STM tubes indicate the same stain temperature on the label) | 2 tubes (per 8 BeadChips) | -15° to -25°C |
FMS | 2 tubes (per 96 samples) | -15° to -25°C |
XC1 | 2 tubes (per 8 BeadChips) | -15° to -25°C |
XC2 | 2 tubes (per 8 BeadChips) | -15° to -25°C |
ATM | 2 tubes (per 8 BeadChips) | -15° to -25°C |
PM1 | 2 tubes (per 96 samples) | 2° to 8°C |
Wash Rack | 1 (up to 8 BeadChips) | Room temperature |
Wash Dish | 2 (up to 8 BeadChips) | Room temperature |
XC4 | 310 ml for 1–8 BeadChips; 285 ml for 16– 24 BeadChips | Room temperature |
Te-Flow Flow-Through Chambers (with black frames, spacers, glass back plates, and clamps) | 1 (per BeadChip) | Room temperature |
XC3 | 50 ml for 1–8 BeadChips; 100 ml for 9–16 BeadChips;150 ml for 17–24 BeadChips | Room temperature |
PB2 | 4x3 or 4x1 HD BeadChip: 3 tubes (per 48 Samples)
| Room temperature |
Hyb Chamber gaskets | 4x3 or 4x1 HD BeadChip: 3 (per 48 Samples) | Room temperature |
Hyb Chamber inserts | 4x3 or 4x1 HD BeadChip: 12 (per 48 Samples) | Room temperature |
Hyb Chamber inserts | 8x1 HD BeadChip: 12 (per 96 Samples) | Room temperature |
BeadChips | 4x3 or 4x1 HD BeadChip: 12 (per 48 Samples) | Room temperature |
BeadChips | 8x1 HD BeadChip: 12 (per 96 Samples) | Room temperature |
Hyb Chamber gaskets | 8x1 HD BeadChip: 3 (per 96 Samples) | Room temperature |
PB1 | 550 ml (up to 8 BeadChips) | Room temperature |
PB1 | 310 ml for 1–8 BeadChips; 285 ml for 9–24 BeadChips | Room temperature |
PB2 | 8x1 HD BeadChip: 2 tubes (per 96 Samples) | Room temperature |
Hyb Chambers | 8x1 HD BeadChip: 3 (per 96 Samples) | Room temperature |
Hyb Chambers | 4x3 or 4x1 HD BeadChip: 3 (per 48 Samples) | Room temperature |
Multi-Sample BeadChip Alignment Fixture | 1 (per 8 BeadChips) | Room temperature |
Item | Quantity | Storage |
95% formamide/1 mM EDTA | 15 ml for 1–8 BeadChips; 17 ml for 9–16 BeadChips; 25 ml for 17–24 BeadChips | -15° to -25°C |
WG#-DNA plate with 96 DNA samples (50 ng/µl) | 1 plate | -15° to -25°C |
96-well 0.8 ml microtiter plate (MIDI) | 1 plate |
|
Lambda DNA | See Instructions | 2° to 8°C |
PicoGreen dsDNA quantitation reagent | See Instructions | 2° to 8°C |
0.1N NaOH | 15 ml (per 96 samples) | 2° to 8°C |
96-well 0.65 ml microtiter plate | 1 per 96 samples | Room temperature |
1X TE (10 mM Tris-HCl pH8.0, 1 mM EDTA (TE)) | See Instructions | Room temperature |
100% 2-propanol | 40 ml (per 96 samples) | Room temperature |
Alconox Powder Detergent | as needed | Room temperature |
EtOH | as needed | Room temperature |
Fluotrac 200 96-well flat-bottom plate | 1 per Std DNA plate 1 per Sample DNA plate | Room temperature |