[Header]
Manifest	CancerHotSpot-v2
Manifest Format Version	1.0
Manifest File Version	20180509
BuildID	hg19
source	ConvertTsaManifestLite 1.22.0.388

[Probes]
Target ID	ULSO Sequence	DLSO Sequence	Gene ID
CHP2_MPL_1	AGAGCGAACCAAGAATGCCTGTTTA	CACTAGATGCAGAGCGGTCACCAAG	MPL
CHP2_NRAS_3	AACAAGTGTGATTTGCCAACAAGGA	GGTACAGCTTTCAGCATTTGTGCAA	NRAS
CHP2_NRAS_2	ACACCCCCAGGATTCTTACAGAAAA	CCAATACATGAGGACAGGCGAAGGC	NRAS
CHP2_NRAS_1	GGTTCTTGCTGGTGTGAAATGACTG	ATATGATCCCACCATAGAGGTGAGG	NRAS
CHP2_ALK_2	CCCTGGAAGAGTGGCCAAGATTGGA	CTTACATCATCTCCTGGTACCCTGT	ALK
CHP2_ALK_1	TTTGCCCAGACTCAGCTCAGTTAAT	CTCAAGTCCTTCCTCCGAGAGACCC	ALK
CHP2_IDH1_1	GAAATCACCAAATGGCACCATACGA	ATGGGGATCAAGTAAGTCATGTTGG	IDH1
CHP2_ERBB4_8	TGGGAACTGATGACCTTTGGAGGAA	GACGTTTACATGGTCATGGTCAAAT	ERBB4
CHP2_ERBB4_7	CAGGGTCCTGACAACTGTACAAAGT	AAGGGTAAGCATTCTTGCTGGCCAA	ERBB4
CHP2_ERBB4_6	CTCAATCCCCTAACTCTGAGTCTTG	TCTTTCTAGTCACTGGTATTCATGG	ERBB4
CHP2_ERBB4_5	TGTTTTGAGCTTGTTTGCTGAATGT	TAAACCTTGCACTGACATTTGCCCA	ERBB4
CHP2_ERBB4_4	TGCAGGCCTGCATGAATTTCAATGA	GTCAAGAAATGTCCACGTAAGTAAC	ERBB4
CHP2_ERBB4_3	GTGACGGCAGATGCTACGGACCTTA	TCCTTTCCTTCCCTATTTGATTCAG	ERBB4
CHP2_ERBB4_2	GACACCATTCATTGGCAAGATATTG	AAATGTTCTACCCTATGTGGCGATG	ERBB4
CHP2_ERBB4_1	AACTTTGGACTTCAAGAACTTGGAT	TTGTTACATTGAGGAACACTCTAAG	ERBB4
CHP2_VHL_1	GCCCGTACCTCGGTAGCTGTGGATG	ATTGCAGAAGATGACCTGGGAGGGC	VHL
CHP2_VHL_2	AACGTCAGTACCTGGCAGTGTGATA	AGCAAAGGTTGTTAAAGAGCCACAC	VHL
CHP2_VHL_3	CTGACGATGTCCAGTCTCCTGTAAT	GAACGAACAAGAGGCTTTGCCAACA	VHL
CHP2_MLH1_1	CCTGCCACTAGAAATATCTGTCTTA	CCAGAAGTAGAAGACGAGGTCAGAC	MLH1
CHP2_CTNNB1_1	CATCCTCTTCCTCAGGATTGCCTTT	TCCATCAAATCAGCTATAAATACGA	CTNNB1
CHP2_PIK3CA_1	AAGGGTTGAAAAAGCCGAAGGTCAC	TCTTGCTTCTTTAAATAGTTCATGC	PIK3CA
CHP2_PIK3CA_2	TACGAAGGTATTGGTTTAGACAGAA	GCCTACTGGTTCAATTACTTTTAAA	PIK3CA
CHP2_PIK3CA_3	ATCAGCATTTGACTTTACCTTATCA	GTGTAGCTGTGGAAATGCGTCTGGA	PIK3CA
CHP2_PIK3CA_4	ATCAGCGGTATAATCAGGAGTTTTT	CATAATTCAGCCATTCATTCCACCT	PIK3CA
CHP2_PIK3CA_5	AACAAGTTTATATTTCCCCATGCCA	AGGAAAATTCAACAATCATCTCTAT	PIK3CA
CHP2_PIK3CA_6	TAAGAGAGAAGGTTTGACTGCCATA	AGGTACTGGCCAAAGATTCAAAGCC	PIK3CA
CHP2_PIK3CA_7	GCACTTACCTGTGACTCCATAGAAA	TCATTGTCTCTAGCTAGTCTGTTAC	PIK3CA
CHP2_PIK3CA_8	TTTGTGTTTCATCCTTCTTCTCCTG	TGTGCATCTCAGATCTAAAAGAATC	PIK3CA
CHP2_PIK3CA_9	GAAAACCATTACTTGTCCATCGTCT	GTAAACAGGTCAATGGCTGCATCAT	PIK3CA
CHP2_PIK3CA_10	GAAGATCCAATCCATTTTTGTTGTC	ATCAAAAGATTGTAGTTCTGGCATT	PIK3CA
CHP2_PIK3CA_11	ATGCTGTTCATGGATTGTGCAATTC	ATGCTGTTTAATTGTGTGGAAGATC	PIK3CA
CHP2_FGFR3_1	GGATGTGGGGCTGTGCGTCACTGTA	AGATGACGCTCAGGGGCCACCCCCT	FGFR3
CHP2_FGFR3_2	CGGTGGGGGAGCCCAGGCCTTTCTT	TCAGCCTCCACCAGCTCCTCCTCGG	FGFR3
CHP2_FGFR3_3	CGCCAGGCGTCCTACTGGCATGACC	ATCACGTTGTCCTCGGTCACCAGCA	FGFR3
CHP2_FGFR3_4	GGGATGCCACTCACAGGTCGTGTGT	AGCGTGAAGATCTCCCAGAGCAGGA	FGFR3
CHP2_FGFR3_5	GGCTGCTAGGGACCCCTCACATTGT	GGAGTACTGCTCGAAAGGCGCCGAC	FGFR3
CHP2_PDGFRA_1	CATCTCTTGGAAACTCCCATCTTGA	GTGAATTACCAAAGTCCCAGTGCAC	PDGFRA
CHP2_PDGFRA_2	ACCACATGTGTCCAGTGAAAATCCT	CAGACATGAGAGCTTGTTTTTCACT	PDGFRA
CHP2_PDGFRA_3	GTGTGCTTTCATCAGCAGGGTTCAA	TAAATGGGGCCTATGGGGACAAAAG	PDGFRA
CHP2_PDGFRA_4	TTAAAGTGAAGGAGGATGAGCCTGA	AGATCACGGTGGACACACTGCATGG	PDGFRA
CHP2_KIT_1	TCCATTTGACAAAGCCCGGATCAGT	TTGAGTATGATCTTCTTCCTTGGCG	KIT
CHP2_KIT_2	GATATGGTAGACAGAGCCTAAACAT	TAAGCCTTACATTCAACCGTGCCAT	KIT
CHP2_KIT_3	TGTCTCAGTCATTAGAGCACTCTGG	AAAGGAGTGAACAGGGTGTGGGGAT	KIT
CHP2_KIT_4	TTTCATACTGACCAAAACTCAGCCT	GGAGAAAGGGAAAAATAGATCACCT	KIT
CHP2_KIT_5	CTTGGACACGGCTTTACCTCCAATG	TTGGAAACATGCATTTTAGCAAAAA	KIT
CHP2_KIT_6	TTGAACAAATAAATGAATCACGTTT	AAGCACATAAGAAAAGGTTAGAAAG	KIT
CHP2_KIT_7	GGACAACATAAGAAACTCCAGGTTT	ATGGGTCATGCTCTACCTCCTCATC	KIT
CHP2_KIT_8	TGTCAAGCAGAGAATGGGTACTCAC	ATGAGTAAGGAGGATATTTCTGGCT	KIT
CHP2_KIT_9	CCTAAAGAGAACAGCTCCCAAAGAA	GTAGTCGAGCCTGTAATAGAAGCAC	KIT
CHP2_KDR_9	ACCACCGTGTACTCCAGTGAGGAAG	CAACTCCTGGACATCACATGAGAGG	KDR
CHP2_KDR_8	TGAGGGTAAAAAGCAAAAGAATTGT	ACTCCGATGACACAGACACCACCGT	KDR
CHP2_KDR_7	TGAGCATGGAAGAGGATTCTGGACT	AGGTACTGTATATGGCCTAACATCC	KDR
CHP2_KDR_6	CAGCATTCAGGAAGAAAGAGGCATT	TGGTGGAACATTTGGGAAATCTCTT	KDR
CHP2_KDR_5	TGGAGCAATCCCTGTGGATCTGAAA	AGAGGAAGGTACTGGCTAGTGCTTC	KDR
CHP2_KDR_4	GGGACCCCAATTATTGAAGGAAATG	CACCATCTCAATGTGGTCAACCTTC	KDR
CHP2_KDR_3	GGCTGCGTTGGAAGTTATTTCTAAG	TACCCTTGTGAAGAATGGAGAAGTG	KDR
CHP2_KDR_2	GCTTTGGAAGTTCAGTCAACTCTTT	CTTAACTATAGATGGTGTAACCCGG	KDR
CHP2_KDR_1	TATCTGTTGGAGAAAAGCTTGTCTT	TGAAGTTTGCTTGAGAGATAGGGGC	KDR
CHP2_FBXW7_5	TCTTGATACATCAATCCGTGTTTGG	TTGTCTCTGGGAATGCAGATTCTAC	FBXW7
CHP2_FBXW7_4	TCCCTCTGCAGAGTTGTTAGCGGTT	TATGATGGCAGGAGGGTTGTTAGTG	FBXW7
CHP2_FBXW7_3	TCATCACAAATGAGAGACAACATCA	GGGAAAATCTTGTCATGGTTGGGAC	FBXW7
CHP2_FBXW7_2	CATCTTTCTTATAGGTGCTGAAAGG	TAAAAGTTTGGTCAGCAGTCACAGG	FBXW7
CHP2_FBXW7_1	TCATTGATAGTTGTGAACCAACACA	AACAGCTACCACCTTTAAACATTGT	FBXW7
CHP2_APC_1	GTATGAATGGCTGACACTTCTTCCA	TAGACCAATTCCGCGTTCTCTCTCC	APC
CHP2_APC_2	CATCTTCTTGACACAAAGACTGGCT	AACTTGAGGTGTTTATCATCAGTGC	APC
CHP2_APC_3	GGATTTGGTTCTAGGGTGCTGTGAC	TTCAGCTGATGACAAAGATGATAAT	APC
CHP2_APC_4	GTGAACTGACAGAAGTACATCTGCT	AACTAGAACCCTGCAGTCTGCTGGA	APC
CHP2_APC_5	GACCCTCTGAACTGCAGCATTTACT	TATCTGGAAGATCACTGGGGCTTAT	APC
CHP2_APC_6	GTCATTTTCCTGAACTGGAGGCATT	TGGAAGAACCTGGACCCTCTGAACT	APC
CHP2_APC_7	TTACGTGATGACTTTGTTGGCATGG	TTTAGGCTGCTCTGATTCTGTTTCA	APC
CHP2_CSF1R_2	AGAGCTCTAGTGAGCACCTGACCTG	AACTTCAACTCCTCCATGGATGGGG	CSF1R
CHP2_CSF1R_1	TCTTCCCACTAATGCCAGATGCTTG	CTCAACCTCAAAGTCATGGTGGAGG	CSF1R
CHP2_NPM1_1	CAGCCAGATATCAACTGTTACAGAA	AGGAACCACAACACTTCATAGACAT	NPM1
CHP2_EGFR_1	GTCCGGTTTTATTTGCATCATAGTT	ACTGTGTTGAGGGCAATGAGGACAT	EGFR
CHP2_EGFR_2	CCCAAAGACTCTCCAAGATGGGATA	ACATCCATCTGGTACGTGGTGGGGT	EGFR
CHP2_EGFR_3	ACTTCCAGACCAGGGTGTTGTTTTC	GTGGAGAAAAATGTTCATGCATGTC	EGFR
CHP2_EGFR_4	CTGTGCCAGGGACCTTACCTTATAC	TGGGTGTAAGAGGCTCCACAAGCTG	EGFR
CHP2_EGFR_5	TGGGCCTGAGGTTCAGAGCCATGGA	TGACAGAGAGAGAAGGAAGACGTTA	EGFR
CHP2_EGFR_6	GTTCCCGGACATAGTCCAGGAGGCA	GTCAGTGTGGCTTCGCATGGTGGCC	EGFR
CHP2_EGFR_7	ATATCCCCATGGCAAACTCTTGCTA	TCTTTGTGTTCCCGGACATAGTCCA	EGFR
CHP2_EGFR_8	CATGTGTTAAACAATACAGCTAGTG	ATCTGTGATCTTGACATGCTGCGGT	EGFR
CHP2_MET_1	AAAGAAGTTGATGAACCGGTCCTTT	GTGAACCTCCGACTGTATGTCAGCA	MET
CHP2_MET_2	AGACATCTCACATTGTTTTTGTTGA	ATCATTCAGGCTGGCTCCTATTTGT	MET
CHP2_MET_3	TTTTCAAAAGGCTTAAACACAGGAT	TCTCTGAATTAGAGCGATGTTGACA	MET
CHP2_MET_4	AGTCTACAGATTCATTTGAAACCAT	CTTGTTAAAGACGGCTATCATGGGC	MET
CHP2_MET_5	AAACCACAAAAGTATACTCCATGGT	AACTTGGTTAGCACTGCGTAACATT	MET
CHP2_MET_6	TGACTTGGTGGTAAACTTTTGAGTT	CTCTGGCAAGACCAAAATCAGCAAC	MET
CHP2_SMO_1	GCCGCGATGTAGCTGTGCATGTCCT	TTGATGTTCTGCACCTCATTCTGGC	SMO
CHP2_SMO_2	GCCAGGCATAGGTGAGGACCACAAA	TCACTCTGTACTCCCTCTACCTGGT	SMO
CHP2_SMO_3	CCTGGTCTTCACTCACCTCGGATGA	AAAACAAATCCCACTCACAGAGTCC	SMO
CHP2_SMO_4	TGCACCAGGTACGCCTCCAGATGAG	TTCTTGATCTCACAGTCAGGGATGG	SMO
CHP2_SMO_5	TCCTCCAGAAGCTTGAACTCTCATA	ATTGAGGTCAAAGGCCAAGCCCGCT	SMO
CHP2_BRAF_2	TGCTCTGATAGGAAAATGAGATCTA	ACAGTTGTCTGGATCCATTTTGTGG	BRAF
CHP2_BRAF_1	TCTTTTTCTGTTTGGCTTGACTTGA	AAGGGAAAGTGGCATGGTAAGTATG	BRAF
CHP2_EZH2_1	CTAGCATCTATTGCTGGCACCATCT	GATAACCTGTATTCAGGTGGCATTG	EZH2
CHP2_FGFR1_2	CCACCCCTCTTTAGCCATGGCAAGG	TTCATGTGTAAGGTGTACAGTGACC	FGFR1
CHP2_FGFR1_1	CTAGGGGTCCCTAGGAGGAACCTCA	TTCCTATCTTACTGCCCTTTGGGTC	FGFR1
CHP2_JAK2_1	ACACTGACACCTAGCTGTGATCCTG	TTGCTCATCATACTTGCTGCTTCAA	JAK2
CHP2_CDKN2A_2	CTTCCTGGACACGCTGGTGGTGCTG	AGTAACCATGCCCGCATAGATGCCG	CDKN2A
CHP2_CDKN2A_1	CCCACCCTGGCTCTGACCATTCTGT	TTCCTGGACACGCTGGTGGTGCTGC	CDKN2A
CHP2_GNAQ_1	TTGTTAACCTTGCAGAATGGTCGAT	AGTGTTCTTTAGACAGGCAATGGAT	GNAQ
CHP2_ABL1_1	ACCGTCAGGCTGTATTTCTTCCACA	AGTTGGGGGACACACCATAGACAGT	ABL1
CHP2_ABL1_2	CAGCTTCTTTCAAGAACTCTTCCAC	ATGCAAAATGGAGCTTCAGCGCATA	ABL1
CHP2_ABL1_3	GCCTGGCCAGGCCCCTACCTGTGGA	TGATATAGAACGGGGGCTCCCGGGT	ABL1
CHP2_ABL1_4	CGGACTTGATGGAGAACTTGTTGTA	CTACCTTCACCAAGTGGTTCTCCCC	ABL1
CHP2_NOTCH1_3	CCACCTGGGCCGGAGCTTCCTGAGT	TGACCGCAGCCCAGTTCCTGACGCC	NOTCH1
CHP2_NOTCH1_2	GCTGCCTCACCATGTCCTGACTGTG	TTGACAACCGGCAGTGTGTGCAGGC	NOTCH1
CHP2_NOTCH1_1	CGGGCTGGACTGTGCGGAGCATGTA	CAACGTGGTCTTCAAGCGTGACGCA	NOTCH1
CHP2_RET_1	CCTCCCTTGTTGGGACCTCAGATGT	TGCCATAGCCAGCTTTAATCCCCCG	RET
CHP2_RET_2	ACTTGTGGTAGCAGTGGATGCAGAA	GGTACAGGCTGCGTATGCTCTGCCT	RET
CHP2_RET_3	GCAGGCCCCATACAATTTGATGACA	AAACGATCGCTCCTGGAAGCCCCTT	RET
CHP2_RET_4	GCCTGCCCCATGGTGCACCTGGGAT	CAAGTCCCGATGAACGAGCTGTGAG	RET
CHP2_RET_5	CTTTGCGTGGTGTAGATATGATCAA	ATCCCTGAGCTTTCAGTAACCAGAG	RET
CHP2_PTEN_1	GCAGCCGCAGAAATGGATACAGGTC	AAGAAAAAGGAGGAGAGAGATGGCA	PTEN
CHP2_PTEN_2	ACCTCACTCTAACAAGCAGATAACT	ACAAACAAACAAAAAGCCACCATTA	PTEN
CHP2_PTEN_3	GCCCCGATGTAATAAATATGCACAT	TTCTAGCTGTGGTGGGTTATGGTCT	PTEN
CHP2_PTEN_4	GCCACTGGTCTATAATCCAGATGAT	CTATGGTAACTGGGTCGTAGCCATT	PTEN
CHP2_PTEN_5	TCTTCACCTTTAGCTGGCAGACCAC	GGATTCTGTATCTGCAATCTTGATC	PTEN
CHP2_PTEN_6	ATTTCTCCCAATGAAAGTAAAGTAC	GTCCTGAATTGGAGGAATATATCTT	PTEN
CHP2_PTEN_7	CGCTCTATACTGCAAATGCTATCGA	TCCTGGTATGAAGAATGTATTTACC	PTEN
CHP2_PTEN_8	TCACATACATACAAGTCAACAACCC	TCATTATCTGCACGCTCTATACTGC	PTEN
CHP2_FGFR2_4	GATGAAGATGATTGGGAAACACAAG	TTTAGAAATGGCTGGGCTTCCAGAT	FGFR2
CHP2_FGFR2_3	TTCCTCCTCCTGTGATCTGCAATCT	AATGAAGAACACGACCAAGAAGCCA	FGFR2
CHP2_FGFR2_2	TCCAGTGGATCAAGCACGTGGAAAA	CCTGTTGGAGTTGAGAGAGGATGAT	FGFR2
CHP2_FGFR2_1	TATTGGTCTCTCATTCTCCCATCCC	GTTTGTCTGCAAGGTTTACAGTGAT	FGFR2
CHP2_HRAS_2	TCCTCCTGCAGGATTCCTACCGGAA	TTTGCCATCAACAACACCAAGTCTT	HRAS
CHP2_HRAS_1	CCTGAGGAGCGATGACGGAATATAA	ACTATAGAGGTGAGCCTGGCGCCGC	HRAS
CHP2_ATM_1	GAAATTTCTAAATGTGACATGACCT	TATGACTTATCTCATTCACTAGCAG	ATM
CHP2_ATM_2	AGATGAAAGGATTCCACTGAAAGTT	AAAATCATTCTGTGACTTCTGAAGG	ATM
CHP2_ATM_3	ATACCATTCTGGCACGCTTTGGAAA	AGAAGACCAAAAGCCATGTAAAGAA	ATM
CHP2_ATM_4	TCCAGGTTCGTTTGCATCACTAACA	CTCCACGGTCAAATGGCTTTTTGAT	ATM
CHP2_ATM_5	CATACCTGTTTTCCCAATAAGTTTT	TACAAGAATCTTTGGAAAGCAGTCT	ATM
CHP2_ATM_6	TCAGCATTATGAAGGTCCACTGAAG	CAGCTTCCAACAGCCTCTACATATA	ATM
CHP2_ATM_7	CTGTAGATAGGCCAGCATTGGATCT	ATTCAAATGCCTATCAAGTACACCA	ATM
CHP2_ATM_8	ATTTCACATTTTGTGCCTCCACTGT	ATCCAGGCCTTCAAAAGGGTTTTCT	ATM
CHP2_ATM_9	GCTGTAAAGTGAGCAGCACAAGACT	TGTTCCTGAAGAAGGTCTAAAGAAA	ATM
CHP2_ATM_10	AAGCGTTTACGATCCTCTTTCAGTG	CACAAAAGCCATGAACTTTAACAGA	ATM
CHP2_ATM_11	TAATTGCAAATTACCTTAATTTCCA	TCTGCTGGAATATTTATGCCTTCTG	ATM
CHP2_ATM_12	CTCACCTTAACAAGCTGTCTCCTCT	AGTCACCAGATTTCCATATTCTCCT	ATM
CHP2_ATM_13	TTTCCGTGTTTCTCTGCAGTAATGT	AAAAACACAGAGTCATCTGAGAATA	ATM
CHP2_ATM_14	ATCTTGGTAGGCAAACAACATTCCA	ATGTAACCAACTGGAGAAAAAAGAA	ATM
CHP2_ATM_15	ATACACAGTCTACCTGGTAAGAAAA	TTCTCACAGCATCTAGAGTCAAACA	ATM
CHP2_ATM_16	AAATTCACTTGTCCACCAACACTGA	AAAACACAAAGGTTTCAGTGAGGTG	ATM
CHP2_ATM_17	TGTTGGCAGGTTAAAAATAAAGGCT	TCTATGGCCTGCTGTATGAGCAAAT	ATM
CHP2_KRAS_3	CTCTGAAGATGTACCTATGGTCCTA	AGGTAAGTAACACTGAAATAAATAC	KRAS
CHP2_KRAS_2	AAGGTGCACTGTAATAATCCAGACT	AATGAGGGACCAGTACATGAGGACT	KRAS
CHP2_KRAS_1	GCCTGCTGAAAATGACTGAATATAA	ATATTACTGGTGCAGGACCATTCTT	KRAS
CHP2_PTPN11_1	TCTTTTAATTGCCCGTGATGTTCCA	AAATAGTCCATTGGAAAGGGAGGCA	PTPN11
CHP2_PTPN11_2	CTGGTACCTGCTCTTCTTCAATCCT	GTCAACACCTACGAAGGAAACATCA	PTPN11
CHP2_HNF1A_1	CTCGCTCCTCCTTGCTAGGGTTCTT	TCACCTGTGGGCTCTTCAATCAGCC	HNF1A
CHP2_HNF1A_2	GGGGGGGCCCGCTGTACGTGTCCAT	CCTGTGCCTGTGATGGGGACACCCC	HNF1A
CHP2_FLT3_4	CACCCACGGGAAAGTGGTGAAGATA	TTTTATACGGCTATTTTGTGTTGTG	FLT3
CHP2_FLT3_3	GAGAGGCACTCATGTCAGAACTCAA	GTAGCTTGATGACAAAGAGGATGTT	FLT3
CHP2_FLT3_2	ACTCATCATTTCATCTCTGAAGCAA	TAGAGTTTGGTAAGAATGGAATGTG	FLT3
CHP2_FLT3_1	GAGCTTATTTCACACGTTCTTTTCT	AGTGTTCAGACAAGTCTCCCAAGTA	FLT3
CHP2_RB1_1	ACCTTTCCAATTTGCTGAAGAGTGC	TATGGACACTACAAAGGAAAGAATA	RB1
CHP2_RB1_2	CCAAGCAGAGAATGAGGGAGGAGTA	ATCCAAGAAACTTTTAGCACCAATG	RB1
CHP2_RB1_3	TGTGCAATACCTGTCTATAGAATCA	TCCTTTACATGTCATTACATCTCTC	RB1
CHP2_RB1_4	CTGGAGTGTGTGGAGGAATTACATT	AAAGCAGTATAATGCTTCTGTTGTC	RB1
CHP2_RB1_5	GATCTTGATGCCTTGACCTCCTGAT	CAAGCGAACTCCAAGTTTGTATCGC	RB1
CHP2_RB1_6	TTGTTAGCCATATGCACATGAATGA	TATCATTTCTCTTGTCAAGTTGCCT	RB1
CHP2_RB1_7	ACAAGCAGATTCAAGGTGATCAGTT	AAACCACATTAGTAAGCATAATTTT	RB1
CHP2_RB1_8	TGCCTGTCTCTCATGAGTTCATACT	TACACTGTGGGAATAAGAAAAATTA	RB1
CHP2_RB1_9	GAGGAAGATCCTTGTATGCTGTTAC	AAAGTAGTCAGAATTTTATTACATG	RB1
CHP2_RB1_10	TTTGACCTACCCTGGTGGAAGCATA	AAACACGTTTGAATGTCTGAGGAAG	RB1
CHP2_AKT1_2	ACCATGAACGAGTTTGAGTACCTGA	AAGGAAGTCATCGTGGCCAAGGTGG	AKT1
CHP2_AKT1_1	GGCGAGGGTCTGACGGGTAGAGTGT	TCAACAACTTCTCTGTGGCGCGTAA	AKT1
CHP2_IDH2_1	AGTTCAAGCTGAAGAAGATGTGGAA	GACCAGGTAGGCCAGGGTGGAGAGG	IDH2
CHP2_CDH1_1	AGTCCCAGGCGTAGACCAAGAAATG	TTTGTCGACCGGTGCAATCTTCAAA	CDH1
CHP2_CDH1_2	ATAGAATTACCGTGGTGGGATTGAA	GACACAACCAAGTCAGGACCAGGAA	CDH1
CHP2_CDH1_3	TCAATATGGTGTATACAGCCTCCCA	TGTGTCATTTACAAAGTACCAAGAC	CDH1
CHP2_TP53_8	ACTTCTCCCCCTCCTCTGTTGCTGC	AGTGACCTCAGCCCCTTCCTGGCCC	TP53
CHP2_TP53_7	CTCTTTTCCTATCCTGAGTAGTGGT	AGCAAGCAGGACAAGAAGCGGTGGA	TP53
CHP2_TP53_6	CCTCATCTTGGGCCTGTGTTATCTC	AAGACTCCAGGTCAGGAGCCACTTG	TP53
CHP2_TP53_5	CCCAGGCCTCTGATTCCTCACTGAT	TGAGGTCTGGTTTGCAACTGGGGTC	TP53
CHP2_TP53_4	GCCCTGTGCAGCTGTGGGTTGATTC	AGAGACGACAGGGCTGGTTGCCCAG	TP53
CHP2_TP53_3	GCCGTCTTCCAGTTGCTTTATCTGT	CAAGACCTGCCCTGTGCAGCTGTGG	TP53
CHP2_TP53_2	TCCAGATGAAGCTCCCAGAATGCCA	TTCTTGCATTCTGGGACAGCCAAGT	TP53
CHP2_TP53_1	GGGTTGGAAGTGTCTCATGCTGGAT	AGACCTATGGAAACTGTGAGTGGAT	TP53
CHP2_ERBB2_1	GAGTCATATCTCCCCAAACCCCAAT	GATGGCCACTGGAATTTTCACATTC	ERBB2
CHP2_ERBB2_2	GCAGCCATAGGGCATAAGCTGTGTC	GTATGGGAGACCACACACCCCCAAA	ERBB2
CHP2_ERBB2_3	CTCCTTGGTCCTTCACCTAACCTTG	ACATCCTCCAGGTAGCTCATCCCCT	ERBB2
CHP2_SMAD4_1	CTACTTACCAATTCCAGGTGATACA	AGACGGGCATAGATCACATGAGGAA	SMAD4
CHP2_SMAD4_2	TTACCTACCATTACTCTGCAGTGTT	TGAACCATTTCAATTCAGAAGTAGC	SMAD4
CHP2_SMAD4_3	TGCTGGTAGCATTAGACTCAGATGG	TCATGCACATATTCATCCTTCACCA	SMAD4
CHP2_SMAD4_4	ATTAAGGCCCACATGGGTTAATTTG	ATGCTATCTGCAACAGTCCTTCACT	SMAD4
CHP2_SMAD4_5	TGAGAAGTGACCCCATAATTCCATT	TCATTGTGAACAGGCCCTAAAGAAA	SMAD4
CHP2_SMAD4_6	TGTCCTGTGGACATTGGAGAGTTGA	ATGGAACACCAATACTCAGGAGCTA	SMAD4
CHP2_SMAD4_7	CTTGGGTAGATCTTATGAACAGCAT	CTATGTGCAACCTTAGGAAGAAAAA	SMAD4
CHP2_SMAD4_8	ATAGCTGGAGCTATTCCACCTACTG	ACACTGACGCAAATCAAAGACCTTT	SMAD4
CHP2_SMAD4_9	GAAGTACTTCGTCTAGGAGCTGGAG	CATCAACACCAATTCCAGCAGCAGC	SMAD4
CHP2_STK11_1	ACAGCGTCTCCGAGTCCAGCACCTC	ATACCCACCGACATCAGCTCGCCCT	STK11
CHP2_STK11_2	GGGTGCCACCGGTGGTGAGCAGCAG	TTGCAGCTGCCTGGGAGCCTCCCAA	STK11
CHP2_STK11_3	AGCCCTGGCTGGTCCGGCAGGTGTC	TTTGAGGGTGCCACCGGTGGTGAGC	STK11
CHP2_STK11_4	GAGGGATGAGGCTCCCACCTTTCAG	GTACAGACCCGTGGTGATGTTGTAG	STK11
CHP2_STK11_5	GGCACCGTGAAGTCCTGAGTGTAGA	TTCAGCCGGAGGATGTTTCTTCCGG	STK11
CHP2_GNA11_1	ACATGATGGATGTCACGTTCTCAAA	CAAGGCCCAATCTGCAATCCCAGGA	GNA11
CHP2_JAK3_3	ACACTTAGCTTGGAAGCTGACAAGT	ACAGAAGGGCAGACTGACATCCAGT	JAK3
CHP2_JAK3_2	GGTCTGTGAGCACAAAATTTGGGAT	TCGTACCGGCATCTCGTGCTGCTCC	JAK3
CHP2_JAK3_1	TACGCAAGGATTTGGCCAGTGCTAT	GAGGACTGGCATGCAATCAGGTGGG	JAK3
CHP2_SRC_1	GCCCGCCTGTGCCTAGAGGTTCTCC	ACATGAGGTCGTGCAGGGACTCGGG	SRC
CHP2_GNAS_1	ATGTCAAGAAACCATGATCTCTGTT	AAATTGAGGTCAATGGATCTCACCA	GNAS
CHP2_GNAS_2	CTGATCCCTAACAACACAGAAGCAA	GGACAGCTGGTTATTCCAGAGGGAC	GNAS
CHP2_SMARCB1_1	AGACGCACCCTTAGTGTTAGGTTTT	TAGTTTCCCACCTATGAGTAAAGCA	SMARCB1
CHP2_SMARCB1_2	GAACTGAAACGTGCTGGAGAACTAA	GGCATCTAAGTGGTGGGAGCTGTTG	SMARCB1
CHP2_SMARCB1_3	CGACTGCCTTGTACCATTCATGTTC	AAGTGAAATGGAAGCAACAGTCAGC	SMARCB1
CHP2_SMARCB1_4	GGCCCAATCTTCTGAGATGCTCCGT	CTCTACAGGGCAGCCAAGTGTAGGG	SMARCB1

[Targets]
TargetA	TargetB	Target Number	Chromosome	Start Position	End Position	Probe Strand	Sequence
CHP2_MPL_1	CHP2_MPL_1	1	chr1	43814944	43815111	+	CTGGGCCTCAGCGCCGTCCTGGGCCTGCTGCTGCTGAGGTGGCAGTTTCCTGCACACTACAGGTACCGCCCCCGCCAGGCAGGAGACTGGCGGTGGACCAGGTGGAGCCGAAGGCCTG
CHP2_NRAS_3	CHP2_NRAS_3	1	chr1	115252161	115252294	+	ATACCTGTCTGGTCTTGGCTGAGGTTTCAATGAATGGAATCCCGTAACTCTTGGCCAGTTCGTGGGCTTGTTTTGTATCAACTG
CHP2_NRAS_2	CHP2_NRAS_2	1	chr1	115256480	115256609	+	TCTCTCATGGCACTGTACTCTTCTTGTCCAGCTGTATCCAGTATGTCCAACAAACAGGTTTCACCATCTATAACCACTTG
CHP2_NRAS_1	CHP2_NRAS_1	1	chr1	115258665	115258799	+	TCATCTACAAAGTGGTTCTGGATTAGCTGGATTGTCAGTGCGCTTTTCCCAACACCACCTGCTCCAACCACCACCAGTTTGTACT
CHP2_ALK_2	CHP2_ALK_2	1	chr2	29432548	29432705	+	GGACAAGCAGCCACACCCCATTCTTGAGGGGCTGAGGTGGAAGAGACAGGCCCGGAGGGGTGAGGCAGTCTTTACTCACCTGTAGATGTCTCGGGCCATCCCGAAGTC
CHP2_ALK_1	CHP2_ALK_1	1	chr2	29443583	29443754	+	GTCTCCCCCCGCCATGAGCTCCAGCAGGATGAACCGGGGCAGGGATTGCAGGCTCACCCCAATGCAGCGAACAATGTTCTGGTGGTTGAATTTGCTGCAGAGCAGAGAGGGATGTAACCAAA
CHP2_IDH1_1	CHP2_IDH1_1	1	chr2	209113079	209113231	+	AAGCATGACGACCTATGATGATAGGTTTTACCCATCCACTCACAAGCCGGGGGATATTTTTGCAGATAATGGCTTCTCTGAAGACCGTGCCACCCAGAATATT
CHP2_ERBB4_8	CHP2_ERBB4_8	1	chr2	212288880	212289015	+	AATAGTGCAGATGGGAGGCTGAGGCAAACGTTCTCCTTTCTCTAATAAATCAGGGATTTCTCGCGTTGGAATTCCATCATAGGGTT
CHP2_ERBB4_7	CHP2_ERBB4_7	1	chr2	212530027	212530205	+	GGGTGCAGTTTGGATGGCATGGGTGGCACTCCCGATCTGGATCAGCATACTTGAAAATGAAACTGTTTGCCCCCTGTAAGCCATCTGGACATTTTTCCACACAGTTTGGGCCATCTTTAAAATGAGAGC
CHP2_ERBB4_6	CHP2_ERBB4_6	1	chr2	212576775	212576935	+	TCAAATTCCCATTGATCTTGGTACAGTTTATGAATTTGTCAATGTTACTGGAATCCACAGTCTGAGCTGACATCAATGATCCTGTGCCAATGCCATCACAAGCTGTAGAAA
CHP2_ERBB4_5	CHP2_ERBB4_5	1	chr2	212578264	212578440	+	CACATTTTAATCCCATTTTCTTCTACTTCCATCTTGGAACTAGGGCAGGCACGCACACAAGAACTGGAATCTACCACAAAGTTATCTGATTAAAAAAAAAAAAAAGGTAAAATAAGCATTAATGTTA
CHP2_ERBB4_4	CHP2_ERBB4_4	1	chr2	212587109	212587264	+	ACAGAATGCTCCATATGTGTACTTTGCATTGAAATTGTGCTCCAGTTGAAAGGTGGTTGGATTGTAGACAAAGGTTTGGGGACACTGAGTAACACATGCTCCACTG
CHP2_ERBB4_3	CHP2_ERBB4_3	1	chr2	212589740	212589892	+	GAGCAGGATAATAAAAGAGAGAAATCACAGACATACAAAGCAGTCTGTGTCCTTAGGTCCTGAGCAGCCTCCAGCACATTCTCGATGGCAGCAGTCACTGACG
CHP2_ERBB4_2	CHP2_ERBB4_2	1	chr2	212652695	212652831	+	TGAGAAATTAAAAAGAATAATTCTACTTACATCCTGAACTACCATTTGTTGACACAAGAGTCAAGTTGGAAGGCCATGGGTTCCGAA
CHP2_ERBB4_1	CHP2_ERBB4_1	1	chr2	212812051	212812194	+	ATATGACAGTAACCCTACATATACAATTGCCTTATATTGATAATGAAAGCATATTTGCCATTTTGGATATATTCCTTACCTGTCAAGTTCTTTA
CHP2_VHL_1	CHP2_VHL_1	1	chr3	10183741	10183879	+	CGCAGTCCGCGCGTCGTGCTGCCCGTATGGCTCAACTTCGACGGCGAGCCGCAGCCCTACCCAACGCTGCCGCCTGGCACGGGCCGCCG
CHP2_VHL_2	CHP2_VHL_2	1	chr3	10188162	10188331	+	TGTCCCGATAGGTCACCTTTGGCTCTTCAGAGATGCAGGGACACACGATGGGCTTCTGGTTAACCAAACTGAATTATTTGTGCCATCTCTCAATGTTGACGGACAGCCTATTTTTGCCAA
CHP2_VHL_3	CHP2_VHL_3	1	chr3	10191394	10191552	+	CTTGTACTGAGACCCTAGTCTGCCACTGAGGATTTGGTTTTTGCCCTTCCAGTGTATACTCTGAAAGAGCGATGCCTCCAGGTTGTCCGGAGCCTAGTCAAGCCTGAGA
CHP2_MLH1_1	CHP2_MLH1_1	1	chr3	37067183	37067358	+	AAGTAGTGATAAGGTCTATGCCCACCAGATGGTTCGTACAGATTCCCGGGAACAGAAGCTTGATGCATTTCTGCAGCCTCTGAGCAAACCCCTGTCCAGTCAGCCCCAGGCCATTGTCACAGAGGA
CHP2_CTNNB1_1	CHP2_CTNNB1_1	1	chr3	41266005	41266172	+	GTTGGACATGGCCATGGAACCAGACAGAAAAGCGGCTGTTAGTCACTGGCAGCAACAGTCTTACCTGGACTCTGGAATCCATTCTGGTGCCACTACCACAGCTCCTTCTCTGAGTGGT
CHP2_PIK3CA_1	CHP2_PIK3CA_1	1	chr3	178916751	178916906	+	AAATACCCCCTCCATCAACTTCTTCAAGATGAATCTTCTTACATTTTCGTAAGTGTTACTCAAGAAGCAGAAAGGGAAGAATTTTTTGATGAAACAAGACGACTTT
CHP2_PIK3CA_2	CHP2_PIK3CA_2	1	chr3	178916907	178917060	+	AACCGTGAAGAAAAGATCCTCAATCGAGAAATTGGTATGATACAATATCCTATTCTAAAATGCAAATAACCATAAAGCTTAACTGTTGTCCCTTTCTAAAATAT
CHP2_PIK3CA_3	CHP2_PIK3CA_3	1	chr3	178921440	178921595	+	CATATATGAATGGAGAAACATCTACAAAATCCCTTTGGGTTATAAATAGTGCACTCAGAATAAAAATTCTTTGTGCAACCTACGTGAATGTAAATATTCGAGACAT
CHP2_PIK3CA_4	CHP2_PIK3CA_4	1	chr3	178927381	178927550	+	ATATATACATTCCTGATCTTCCTCGTGCTGCTCGACTTTGCCTTTCCATTTGCTCTGTTAAAGGCCGAAAGGGTGCTAAAGAGGTAAAGTATTTCAGAAGGAACAATTATGTTTACCTTT
CHP2_PIK3CA_5	CHP2_PIK3CA_5	1	chr3	178927877	178928011	+	TTTGGGGAAGAAAAGTGTTTTGAAATGTGTTTTATAATTTAGACTAGTGAATATTTTTCTTTGTTTTTTAAGGAACACTGTCCAT
CHP2_PIK3CA_6	CHP2_PIK3CA_6	1	chr3	178928045	178928185	+	CATGGATTAGAAGATTTGCTGAACCCTATTGGTGTTACTGGATCAAATCCAAATAAAGTAAGGTTTTTATTGTCATAAATTAGATATTTTT
CHP2_PIK3CA_7	CHP2_PIK3CA_7	1	chr3	178935999	178936130	+	ATTAAGGGAAAATGACAAAGAACAGCTCAAAGCAATTTCTACACGAGATCCTCTCTCTGAAATCACTGAGCAGGAGAAAGAT
CHP2_PIK3CA_8	CHP2_PIK3CA_8	1	chr3	178938763	178938943	+	ATAAAACAGTTAGCCAGAGGTTTGGCCTGCTTTTGGAGTCCTATTGTCGTGCATGTGGGATGTATTTGAAGCACCTGAATAGGCAAGTCGAGGCAATGGAAAAGCTCATTAACTTAACTGACATTCTCAAA
CHP2_PIK3CA_9	CHP2_PIK3CA_9	1	chr3	178947794	178947921	+	ACGTTCATGTGCTGGATACTGTGTAGCTACCTTCATTTTGGGAATTGGAGATCGTCACAATAGTAACATCATGGTGAA
CHP2_PIK3CA_10	CHP2_PIK3CA_10	1	chr3	178951972	178952122	+	GACATTGCATACATTCGAAAGACCCTAGCCTTAGATAAAACTGAGCAAGAGGCTTTGGAGTATTTCATGAAACAAATGAATGATGCACATCATGGTGGCTG
CHP2_PIK3CA_11	CHP2_PIK3CA_11	1	chr3	178952116	178952262	+	GCATTGAACTGAAAAGATAACTGAGAAAATGAAAGCTCACTCTGGATTCCACACTGCACTGTTAATAACTCTCAGCAGGCAAAGACCGATTGCATAG
CHP2_FGFR3_1	CHP2_FGFR3_1	1	chr4	1803527	1803678	+	GCCCCCACAGAGCGCTCCCCGCACCGGCCCATCCTGCAGGCGGGGCTGCCGGCCAACCAGACGGCGGTGCTGGGCAGCGACGTGGAGTTCCACTGCAAGGTG
CHP2_FGFR3_2	CHP2_FGFR3_2	1	chr4	1806057	1806212	+	CGAGGCGGGCAGTGTGTATGCAGGCATCCTCAGCTACGGGGTGGGCTTCTTCCTGTTCATCCTGGTGGTGGCGGCTGTGACGCTCTGCCGCCTGCGCAGCCCCCCC
CHP2_FGFR3_3	CHP2_FGFR3_3	1	chr4	1807809	1807955	+	GAAGATCGCAGACTTCGGGCTGGCCCGGGACGTGCACAACCTCGACTACTACAAGAAGACGACCAACGTGAGCCCGGCCCTGGGGTGCGGGGGTGGG
CHP2_FGFR3_4	CHP2_FGFR3_4	1	chr4	1808287	1808424	+	GGGGGGCTCCCCGTACCCCGGCATCCCTGTGGAGGAGCTCTTCAAGCTGCTGAAGGAGGGCCACCGCATGGACAAGCCCGCCAACTGC
CHP2_FGFR3_5	CHP2_FGFR3_5	1	chr4	1808857	1809031	+	CCGGGTGGCCAGGACACCCCCAGCTCCAGCTCCTCAGGGGACGACTCCGTGTTTGCCCACGACCTGCTGCCCCCGGCCCCACCCAGCAGTGGGGGCTCGCGGACGTGAAGGGCCACTGGTCCCCA
CHP2_PDGFRA_1	CHP2_PDGFRA_1	1	chr4	55140957	55141128	+	CAGTTACCTGTCCTGGTCATTTATAGAAACCGAGGTATGAAATTCGCTGGAGGGTCATTGAATCAATCAGCCCAGATGGACATGAATATATTTATGTGGACCCGATGCAGCTGCCTTATGAC
CHP2_PDGFRA_2	CHP2_PDGFRA_2	1	chr4	55144077	55144220	+	AACTGAAGATAATGACTCACCTGGGGCCACATTTGAACATTGTAAACTTGCTGGGAGCCTGCACCAAGTCAGGTGGGCTCACTGACCTGGAGTG
CHP2_PDGFRA_3	CHP2_PDGFRA_3	1	chr4	55144514	55144678	+	CATCATCACAGAGTATTGCTTCTATGGAGATTTGGTCAACTATTTGCATAAGAATAGGGATAGCTTCCTGAGCCACCACCCAGAGAAGCCAAAGAAAGAGCTGGATATCTTTGGA
CHP2_PDGFRA_4	CHP2_PDGFRA_4	1	chr4	55152000	55152179	+	GGCTGCTCGCAACGTCCTCCTGGCACAAGGAAAAATTGTGAAGATCTGTGACTTTGGCCTGGCCAGAGACATCATGCATGATTCGAACTATGTGTCGAAAGGCAGTGTACGTCCTCACTTCCCTCACTGG
CHP2_KIT_1	CHP2_KIT_1	1	chr4	55561630	55561809	+	CACGATTCTGTTTTTCTTGGCAGGCTCTTCTCAACCATCTGTGAGTCCAGGGGAACCGTCTCCACCATCCATCCATCCAGGAAAATCAGACTTAATAGTCCGCGTGGGCGACGAGATTAGGCTGTTATGC
CHP2_KIT_2	CHP2_KIT_2	1	chr4	55592133	55592271	+	CAACGATGTGGGCAAGACTTCTGCCTATTTTAACTTTGCATTTAAAGGTAACAACAAAGGTATATTTCTTTTTAATCCAATTTAAGGGG
CHP2_KIT_3	CHP2_KIT_3	1	chr4	55593393	55593538	+	GCTGATTGGTTTCGTAATCGTAGCTGGCATGATGTGCATTATTGTGATGATTCTGACCTACAAATATTTACAGGTAACCATTTATTTGTTCTCTCT
CHP2_KIT_4	CHP2_KIT_4	1	chr4	55593551	55593720	+	CCACAGAAACCCATGTATGAAGTACAGTGGAAGGTTGTTGAGGAGATAAATGGAAACAATTATGTTTACATAGACCCAACACAACTTCCTTATGATCACAAATGGGAGTTTCCCAGAAAC
CHP2_KIT_5	CHP2_KIT_5	1	chr4	55594146	55594304	+	TTTTAGCGAGTGCCCATTTGACAGAACGGGAAGCCCTCATGTCTGAACTCAAAGTCCTGAGTTACCTTGGTAATCACATGAATATTGTGAATCTACTTGGAGCCTGCAC
CHP2_KIT_6	CHP2_KIT_6	1	chr4	55595472	55595587	+	TTAGGGCCCACCCTGGTCATTACAGAATATTGTTGCTATGGTGATCTTTTGAATTTTTTGAGAAGA
CHP2_KIT_7	CHP2_KIT_7	1	chr4	55597412	55597549	+	GAGTGCCCTTCTACATGTCCCACTTGATTCAGTCATGACTTGTTTCATCTCTCCCAGCAGCGATAGTACTAATGAGTACATGGACATG
CHP2_KIT_8	CHP2_KIT_8	1	chr4	55599256	55599383	+	GGTCGGATCACAAAGATTTGTGATTTTGGTCTAGCCAGAGACATCAAGAATGATTCTAATTATGTGGTTAAAGGAAAC
CHP2_KIT_9	CHP2_KIT_9	1	chr4	55602649	55602776	+	CTGTGAAGTGGATGGCACCTGAAAGCATTTTCAACTGTGTATACACGTTTGAAAGTGACGTCTGGTCCTATGGGATTT
CHP2_KDR_9	CHP2_KDR_9	1	chr4	55946064	55946233	+	GGGGTGTGGATGCTTCCTTTTAAACAGGAGGAGAGCTCAGTGTGGTCCCCGAGTCAGGCTGGAGAATCTGGGCTGTGCTACCGGTTTGCACTCCAATCTCTATCAGCTTTAAAAGTTCTG
CHP2_KDR_8	CHP2_KDR_8	1	chr4	55946226	55946396	+	GATATCCGGACTGGTAGCCGCTTGTCTGGTTTGAGCCTTCAGATGCCACAGACTCCCTGCTTTTGCTGGGCACCATTCCACTGCAGAAGAAATGGCAAACAAAGGAGTTGGCAGAGAGAAG
CHP2_KDR_7	CHP2_KDR_7	1	chr4	55953751	55953885	+	GATTCCTGCTGTGTTGTCATAATGGAATTTGGGGTCACATACTTCCTCCTCCTCCATACAGGAAACAGGTGAGGTAGGCAGAGAG
CHP2_KDR_6	CHP2_KDR_6	1	chr4	55955054	55955193	+	ACTCTGAAAACGTGGGTCTCTGACTGGGCTCCCCGTGCCAGCAGTCCAGCATGGTCTGGTACCTAGAGAAGCAAAACACTGATTTCATTA
CHP2_KDR_5	CHP2_KDR_5	1	chr4	55960952	55961084	+	TCTTCTACATCACTGAGGGACTTCTCCTCCACAAATCCAGAGCTGGCTGAGCTCTGGCTACTGGTGATGCTGTCCAAGCGCCG
CHP2_KDR_4	CHP2_KDR_4	1	chr4	55962420	55962573	+	ACCAATATGAATGAGGATCTTGAGTTCAGACATGAGAGCTCGATGCTCACTGTGTGTTGCTCCTTCTACAAATACAGTACAAAGAGGGAAATCATAGGTATGGA
CHP2_KDR_3	CHP2_KDR_3	1	chr4	55972928	55973096	+	TGGGTTTGTCACTGAGACAGCTTGGCTATAAGAAAGAGATAACAGCGCATATTATGATTTAATTTTTCTTTAATTAGAGTCAAGAGTAAGGAAAAGATTCAGACTTTGGTTATTCTGTT
CHP2_KDR_2	CHP2_KDR_2	1	chr4	55979550	55979680	+	GTGCTCAAAAATTTCTTCATCTCACTCCCAGACTGGGTTTTTAGGTCTCGGTTTACAAGTTTCTTATGCTGATGCTGAAAA
CHP2_KDR_1	CHP2_KDR_1	1	chr4	55980214	55980384	+	CTGGGGCTTATTATCTAAGTATTTGGAGGTCTGGCTTTGAATCATTAGCGTTACCTTCGAAGAAGGGTATTCCCAGTTGAAGTCAATCCCCACATTTAGTTCAGTTCTTGCTGTACAATTT
CHP2_FBXW7_5	CHP2_FBXW7_5	1	chr4	153245386	153245517	+	GAATATTGTCTTTGAGTTCCATTCCACTTGTTAACGACTGGTGCCCTGTTAACGTGTGAATGCAATTCCCTGTCTCCACATC
CHP2_FBXW7_4	CHP2_FBXW7_4	1	chr4	153247253	153247394	+	TTGAACACAGCGGACTGCTGCAACATGACCCATCAAAACATGTAAACACTGGCCTGTCTCAATATCCCAAACCCTAAGAGTGGCATCTCGAG
CHP2_FBXW7_3	CHP2_FBXW7_3	1	chr4	153249331	153249502	+	TTACCTTTTTTCATGAAGATGCATACAACGCACAGTGGAAGTATGCCCATATAAGGTGTGTATACATTCTCCAGTCTCTGCATTCCACACTTTGAGTGTCCGATCTGTAGATCCACTAATGA
CHP2_FBXW7_2	CHP2_FBXW7_2	1	chr4	153250828	153250951	+	AAGTGTTGTCATCAGAACCACTAACTATTCGGTTACCACAAAACTGTAAGCATGTGATCACATGATCATCATGT
CHP2_FBXW7_1	CHP2_FBXW7_1	1	chr4	153258877	153259048	+	GAGTTATATATTCAAATAACACCCAATGAAGAATGTAATTGATAATCTTTACCTCTTTAGGGAGCAATGAAATGAAGTCTCGTTGAAACTGGGGTTCTATCACTTGCATCATATGTTTTACT
CHP2_APC_1	CHP2_APC_1	1	chr5	112173847	112173987	+	GGCAACTACCATCCAGCAACAGAAAATCCAGGAACTTCTTCAAAGCGAGGTTTGCAGATCTCCACCACTGCAGCCCAGATTGCCAAAGTCA
CHP2_APC_2	CHP2_APC_2	1	chr5	112174533	112174691	+	CCAACCACATTTTGGACAGCAGGAATGTGTTTCTCCATACAGGTCACGGGGAGCCAATGGTTCAGAAACAAATCGAGTGGGTTCTAATCATGGAATTAATCAAAATGTA
CHP2_APC_3	CHP2_APC_3	1	chr5	112175119	112175293	+	GATGAAATAGGATGTAATCAGACGACACAGGAAGCAGATTCTGCTAATACCCTGCAAATAGCAGAAATAAAAGAAAAGATTGGAACTAGGTCAGCTGAAGATCCTGTGAGCGAAGTTCCAGCAGT
CHP2_APC_4	CHP2_APC_4	1	chr5	112175291	112175468	+	TATCTTCAGAATCAGCCAGGCACAAAGCTGTTGAATTTTCTTCAGGAGCGAAATCTCCCTCCAAAAGTGGTGCTCAGACACCCAAAAGTCCACCTGAACACTATGTTCAGGAGACCCCACTCATGTTT
CHP2_APC_5	CHP2_APC_5	1	chr5	112175543	112175728	+	GCCCTGGACAAACCATGCCACCAAGCAGAAGTAAAACACCTCCACCACCTCCTCAAACAGCTCAAACCAAGCGAGAAGTACCTAAAAATAAAGCACCTACTGCTGAAAAGAGAGAGAGTGGACCTAAGCAAGCTGC
CHP2_APC_6	CHP2_APC_6	1	chr5	112175716	112175887	+	GATGCTGATACTTTATTACATTTTGCCACGGAAAGTACTCCAGATGGATTTTCTTGTTCATCCAGCCTGAGTGCTCTGAGCCTCGATGAGCCATTTATACAGAAAGATGTGGAATTAAGAAT
CHP2_APC_7	CHP2_APC_7	1	chr5	112175896	112176060	+	GAATCAAATGAAAACCAAGAGAAAGAGGCAGAAAAAACTATTGATTCTGAAAAGGACCTATTAGATGATTCAGATGATGATGATATTGAAATACTAGAAGAATGTATTATTTCTG
CHP2_CSF1R_2	CHP2_CSF1R_2	1	chr5	149433569	149433717	+	TGTGGGAGGGGAGAGTGGTACTCCCTGTCGTCAACTCCTCAGCAGAACTGATAGTTGTTGGGCTGCAGCAAGGGCTGGGCGATATCCCCTTGCTCGCAG
CHP2_CSF1R_1	CHP2_CSF1R_1	1	chr5	149452967	149453098	+	CCCCTCCCCCACGGTCACCTCCTGGATGAGGTTCTGCTCAGAGCTCAAGTTCAAGTAGGCACTCTCTGGAAAGCAGAACACA
CHP2_NPM1_1	CHP2_NPM1_1	1	chr5	170837477	170837641	+	TAACCACATTTCTTTTTTTTTTTTTCCAGGCTATTCAAGATCTCTGGCAGTGGAGGAAGTCTCTTTAAGAAAATAGTTTAAACAATTTGTTAAAAAATTTTCCGTCTTATTTCAT
CHP2_EGFR_1	CHP2_EGFR_1	1	chr7	55211020	55211151	+	GGAGCGAATTCCTTTGGAAAACCTGCAGATCATCAGAGGAAATATGTACTACGAAAATTCCTATGCCTTAGCAGTCTTATCT
CHP2_EGFR_2	CHP2_EGFR_2	1	chr7	55221768	55221944	+	GAACCCCGAGGGCAAATACAGCTTTGGTGCCACCTGCGTGAAGAAGTGTCCCCGTGAGTCCTCCTCTGTGGGCCCTCTAACTGGTCAGGCATCCTTGTCCCGCTCTGTCTCCTGCTGAGCCCTGGAG
CHP2_EGFR_3	CHP2_EGFR_3	1	chr7	55232938	55233078	+	CTTGGTGCAGGGACCAGACAACTGTATCCAGTGTGCCCACTACATTGACGGCCCCCACTGCGTCAAGACCTGCCCGGCAGGAGTCATGGGA
CHP2_EGFR_4	CHP2_EGFR_4	1	chr7	55241611	55241754	+	GTGGAGAAGCTCCCAACCAAGCTCTCTTGAGGATCTTGAAGGAAACTGAATTCAAAAAGATCAAAGTGCTGGGCTCCGGTGCGTTCGGCACGGT
CHP2_EGFR_5	CHP2_EGFR_5	1	chr7	55242387	55242565	+	TAGGGACTCTGGATCCCAGAAGGTGAGAAAGTTAAAATTCCCGTCGCTATCAAGGAATTAAGAGAAGCAACATCTCCGAAAGCCAACAAGGAAATCCTCGATGTGAGTTTCTGCTTTGCTGTGTGGGGG
CHP2_EGFR_6	CHP2_EGFR_6	1	chr7	55248941	55249115	+	GTGCCTCTCCCTCCCTCCAGGAAGCCTACGTGATGGCCAGCGTGGACAACCCCCACGTGTGCCGCCTGCTGGGCATCTGCCTCACCTCCACCGTGCAGCTCATCACGCAGCTCATGCCCTTCGGC
CHP2_EGFR_7	CHP2_EGFR_7	1	chr7	55249098	55249270	+	CAATATTGGCTCCCAGTACCTGCTCAACTGGTGTGTGCAGATCGCAAAGGTAATCAGGGAAGGGAGATACGGGGAGGGGAGATAAGGAGCCAGGATCCTCACATGCGGTCTGCGCTCCTGGGA
CHP2_EGFR_8	CHP2_EGFR_8	1	chr7	55259483	55259653	+	TTTGGGCTGGCCAAACTGCTGGGTGCGGAAGAGAAAGAATACCATGCAGAAGGAGGCAAAGTAAGGAGGTGGCTTTAGGTCAGCCAGCATTTTCCTGACACCAGGGACCAGGCTGCCTTCC
CHP2_MET_1	CHP2_MET_1	1	chr7	116339591	116339726	+	TGCATATTCTCCCCACAGATAGAAGAGCCCAGCCAGTGTCCTGACTGTGTGGTGAGCGCCCTGGGAGCCAAAGTCCTTTCATCTGT
CHP2_MET_2	CHP2_MET_2	1	chr7	116340131	116340295	+	GACATTCTTTTCGGGGTGTTCGCACAAAGCAAGCCAGATTCTGCCGAACCAATGGATCGATCTGCCATGTGTGCATTCCCTATCAAATATGTCAACGACTTCTTCAACAAGATCG
CHP2_MET_3	CHP2_MET_3	1	chr7	116403107	116403276	+	TAATCTGTTGTACCACTCCTTCCCTGCAACAGCTGAATCTGCAACTCCCCCTGAAAACCAAAGCCTTTTTCATGTTAGATGGGATCCTTTCCAAATACTTTGATCTCATTTATGTACATA
CHP2_MET_4	CHP2_MET_4	1	chr7	116411854	116412022	+	CTCTTTCTTTCTCTCTGTTTTAAGATCTGGGCAGTGAATTAGTTCGCTACGATGCAAGAGTACACACTCCTCATTTGGATAGGCTTGTAAGTGCCCGAAGTGTAAGCCCAACTACAGAA
CHP2_MET_5	CHP2_MET_5	1	chr7	116417403	116417567	+	CTTTCTTTTGCACAGGGCATTTTGGTTGTGTATATCATGGGACTTTGTTGGACAATGATGGCAAGAAAATTCACTGTGCTGTGAAATCCTTGAACAGTAAGTGGCATTTTATTTA
CHP2_MET_6	CHP2_MET_6	1	chr7	116423383	116423517	+	ACATGTATGATAAAGAATACTATAGTGTACACAACAAAACAGGTGCAAAGCTGCCAGTGAAGTGGATGGCTTTGGAAAGTCTGCA
CHP2_SMO_1	CHP2_SMO_1	1	chr7	128845039	128845213	+	GTTCAACAGTTCAGGCCAGTGCGAAGTGCCCTTGGTTCGGACAGACAACCCCAAGAGCTGGTACGAGGACGTGGAGGGCTGCGGCATCCAGTGCCAGAACCCGCTCTTCACAGAGGCTGAGCACC
CHP2_SMO_2	CHP2_SMO_2	1	chr7	128845933	128846088	+	CCGCCTCAAGTGACACCTCACCTCTCTGCACAGCTCCAATGAGACTCTGTCCTGCGTCATCATCTTTGTCATCGTGTACTACGCCCTGATGGCTGGTGTGGTTTGG
CHP2_SMO_3	CHP2_SMO_3	1	chr7	128846313	128846444	+	GTGGGCTACAAGAACTACCGATACCGTGCGGGCTTCGTGCTGGCCCCAATCGGCCTGGTGCTCATCGTGGGAGGCTACTTCC
CHP2_SMO_4	CHP2_SMO_4	1	chr7	128850245	128850388	+	TCGCCCGAGCCTTCTGGTGGAGAAGATCAACCTGTTTGCCATGTTTGGAACTGGCATCGCCATGAGCACCTGGGTCTGGACCAAGGCCACGCTG
CHP2_SMO_5	CHP2_SMO_5	1	chr7	128851475	128851637	+	GAGCCCTCAGCTGATGTCTCCTCTGCCTGGGCCCAGCATGTCACCAAGATGGTGGCTCGGAGAGGAGCCATACTGCCCCAGGATATTTCTGTCACCCCTGTGGCAACTCCAGG
CHP2_BRAF_2	CHP2_BRAF_2	1	chr7	140453078	140453246	+	TCAAACTGATGGGACCCACTCCATCGAGATTTCACTGTAGCTAGACCAAAATCACCTATTTTTACTGTGAGGTCTTCATGAAGAAATATATCTGAGGTGTAGTAAGTAAAGGAAAACAG
CHP2_BRAF_1	CHP2_BRAF_1	1	chr7	140481367	140481540	+	GTAGACTGTTCCAAATGATCCAGATCCAATTCTTTGTCCCACTGTAATCTGCCCATCAGGAATCTCCCAATCATCACTCGAGTCCCGTCTACCAAGTGTTTTCTTGATAAAAACAGTAAAAAAG
CHP2_EZH2_1	CHP2_EZH2_1	1	chr7	148508682	148508816	+	AGTGCCTTACCTCTCCACAGTATTCTGAGATGAATTCATTTTTCTGCACAGGATCTTTGATAAAAATCCCCCAGCCTGCCACGTC
CHP2_FGFR1_2	CHP2_FGFR1_2	1	chr8	38282116	38282279	+	CTCCACGTTGCTACCCAGGGCCACTGTTTTGTTGGCGGGCAACCCTGCTTGCAGGATGGGCCGGTGAGGGGACCGCTCTGTGGAAGATGGGAGAGGAGGCACTTGTCATGGGGA
CHP2_FGFR1_1	CHP2_FGFR1_1	1	chr8	38285827	38286000	+	ACAGTGTCTCACGCATACGGTTTGGTTTGGTGTTATCTGTTTCTTTCTCCTCTGAAGAGGAGTCATCATCATCATCATCATCCTCCGAGGAGGGGAGAGCATCTATGGGAAGAAGAAGGGGCAC
CHP2_JAK2_1	CHP2_JAK2_1	1	chr9	5073705	5073882	+	GCTTTCTCACAAGCATTTGGTTTTAAATTATGGAGTATGTGTCTGTGGAGACGAGAGTAAGTAAAACTACAGGCTTTCTAATGCCTTTCTCAGAGCATCTGTTTTTGTTTATATAGAAAATTCAGTTT
CHP2_CDKN2A_2	CHP2_CDKN2A_2	1	chr9	21970916	21971091	+	GCCTCTGGTGCCCCCCGCAGCCGCGCGCAGGTACCGTGCGACATCGCGATGGCCCAGCTCCTCAGCCAGGTCCACGGGCAGACGGCCCCAGGCATCGCGCACGTCCAGCCGCGCCCCGGCCCGGTG
CHP2_CDKN2A_1	CHP2_CDKN2A_1	1	chr9	21971066	21971244	+	GCCCTCCCGGGCAGCGTCGTGCACGGGTCGGGTGAGAGTGGCGGGGTCGGCGCAGTTGGGCTCCGCGCCGTGGAGCAGCAGCAGCTCCGCCACTCGGGCGCTGCCCATCATCATGACCTGCCAGAGAGA
CHP2_GNAQ_1	CHP2_GNAQ_1	1	chr9	80409351	80409523	+	TACCTCATTGTCTGACTCCACGAGAACTTGATCATATTCACTAAGCGCTACTAGAAACATGATAGAGGTGACATTTTCAAAGCAGTGTATCCATTTTCTTCTCTCTGACCTTTGGCCCCCTAC
CHP2_ABL1_1	CHP2_ABL1_1	1	chr9	133738270	133738403	+	ACGACAAGTGGGAGATGGAACGCACGGACATCACCATGAAGCACAAGCTGGGCGGGGGCCAGTACGGGGAGGTGTACGAGGGCG
CHP2_ABL1_2	CHP2_ABL1_2	1	chr9	133747418	133747555	+	TAACTAGTCAAGTACTTACCCACTGAAAAGCACTTCCTGAAATAATTTCACCTTCGTTTTTTTCCTTCTGCAGGAGGACACCATGGAG
CHP2_ABL1_3	CHP2_ABL1_3	1	chr9	133748255	133748442	+	TCACTGAGTTCATGACCTACGGGAACCTCCTGGACTACCTGAGGGAGTGCAACCGGCAGGAGGTGAACGCCGTGGTGCTGCTGTACATGGCCACTCAGATCTCGTCAGCCATGGAGTACCTGGAGAAGAAAAACTTCA
CHP2_ABL1_4	CHP2_ABL1_4	1	chr9	133750283	133750430	+	CTGATTTTGGCCTGAGCAGGTTGATGACAGGGGACACCTACACAGCCCATGCTGGAGCCAAGTTCCCCATCAAATGGACTGCACCCGAGAGCCTGGCC
CHP2_NOTCH1_3	CHP2_NOTCH1_3	1	chr9	139390740	139390910	+	CGGGTGGGACCAGCGAGGATGGCAGCGACGTGGGCAGGGCGGGGCTCTCCTGGGGCAGAATAGTGTGCACCGCCAGGCTGCTGGGGCCCAGTGGCTGCACGTCTGCCTGGCTCGGCTCTCC
CHP2_NOTCH1_2	CHP2_NOTCH1_2	1	chr9	139397738	139397904	+	TCTCCAGGTAGACGATGGAGCTGGGCGGACAATCAGAGAGGGGCTGGGACCCGAGGCTTCCTCCTCCCCCGCCCACCGGCCAGGGATGCTGCCGCAGGACACTGAGGCCCATGACGC
CHP2_NOTCH1_1	CHP2_NOTCH1_1	1	chr9	139399313	139399472	+	GTGTGCAGCACGCGGCTGAGCTCCCGCAGGAAGTGGAAGGAGCTGTTGCGCAGCTGCTCCGGCGGCATCAGCACCACCACCACCAGCGTGCCGGCCGCCAGCCTCTCGGG
CHP2_RET_1	CHP2_RET_1	1	chr10	43609042	43609207	+	CCTGCAACTGCTTCCCTGAGGAGGAGAAGTGCTTCTGCGAGCCCGAAGACATCCAGGGTGAGTGGGTGGCGGCCGGGACCACCACCACCTCCCAGCCCCACAGAGGTCTCAACAGC
CHP2_RET_2	CHP2_RET_2	1	chr10	43609850	43610035	+	CAGTGGTGCCGAGCCTCTGGCGGTGCCAAGCCTCACACCACCCCCACCCACAGATCCACTGTGCGACGAGCTGTGCCGCACGGTGATCGCAGCCGCTGTCCTCTTCTCCTTCATCGTCTCGGTGCTGCTGTCTGCC
CHP2_RET_3	CHP2_RET_3	1	chr10	43613770	43613918	+	GCAACCTGCTCTGTGCTGCATTTCAGAGAACGCCTCCCCGAGTGAGCTGCGAGACCTGCTGTCAGAGTTCAACGTCCTGAAGCAGGTCAACCACCCACA
CHP2_RET_4	CHP2_RET_4	1	chr10	43615522	43615712	+	GCAGCCAGAAACATCCTGGTAGCTGAGGGGCGGAAGATGAAGATTTCGGATTTCGGCTTGTCCCGAGATGTTTATGAAGAGGATTCCTACGTGAAGAGGAGCCAGGTGCCCAGTCCCGGGGATGAGGCGGGGCTCCCAGGG
CHP2_RET_5	CHP2_RET_5	1	chr10	43617290	43617458	+	AGGGCCTGGCCTTCTCCTTTACCCCTCCTTCCTAGAGAGTTAGAGTAACTTCAATGTCTTTATTCCATCTTCTCTTTAGGGTCGGATTCCAGTTAAATGGATGGCAATTGAATCCCTTT
CHP2_PTEN_1	CHP2_PTEN_1	1	chr10	89624183	89624325	+	CAGCCACAGGCTCCCAGACATGACAGCCATCATCAAAGAGATCGTTAGCAGAAACAAAAGGAGATATCAAGAGGATGGATTCGACTTAGACTT
CHP2_PTEN_2	CHP2_PTEN_2	1	chr10	89685234	89685399	+	TTTGTTTTAAGGTTTTTGGATTCAAAGCATAAAAACCATTACAAGATATACAATCTGTAAGTATGTTTTCTTATTTGTATGCTTGCAAATATCTTCTAAAACAACTATTAAGTGAA
CHP2_PTEN_3	CHP2_PTEN_3	1	chr10	89692789	89692945	+	CTTATCAAACCCTTTTGTGAAGATCTTGACCAATGGCTAAGTGAAGATGACAATCATGTTGCAGCAATTCACTGTAAAGCTGGAAAGGGACGAACTGGTGTAATGAT
CHP2_PTEN_4	CHP2_PTEN_4	1	chr10	89711780	89711957	+	CAATTTAGTGAAATAACTATAATGGAACATTTTTTTTCAATTTGGCTTCTCTTTTTTTTCTGTCCACCAGGGAGTAACTATTCCCAGTCAGAGGCGCTATGTGTATTATTATAGCTACCTGTTAAAGA
CHP2_PTEN_5	CHP2_PTEN_5	1	chr10	89717479	89717645	+	ATATTTCGTGTATATTGCTGATATTAATCATTAAAATCGTTTTTGACAGTTTGACAGTTAAAGGCATTTCCTGTGAAATAATACTGGTATGTATTTAACCATGCAGATCCTCAGTTT
CHP2_PTEN_6	CHP2_PTEN_6	1	chr10	89717642	89717805	+	CCACACGACGGGAAGACAAGTTCATGTACTTTGAGTTCCCTCAGCCGTTACCTGTGTGTGGTGATATCAAAGTAGAGTTCTTCCACAAACAGAACAAGATGCTAAAAAAGGTTT
CHP2_PTEN_7	CHP2_PTEN_7	1	chr10	89720671	89720772	+	CCAGAGGAAACCTCAGAAAAAGTAGAAAATGGAAGTCTATGTGATCAAGAAA
CHP2_PTEN_8	CHP2_PTEN_8	1	chr10	89720760	89720925	+	CAAGGAATATCTAGTACTTACTTTAACAAAAAATGATCTTGACAAAGCAAATAAAGACAAAGCCAACCGATACTTTTCTCCAAATTTTAAGGTCAGTTAAATTAAACATTTTGTGG
CHP2_FGFR2_4	CHP2_FGFR2_4	1	chr10	123257928	123258070	+	ATGATTCAATCAAACTGCAGAGTATTTGGGCGAATGCAGTTTTTCCTCCTACTCACCATCCTGTGTGCAGGCTCCAAGAAGATTTATGATATT
CHP2_FGFR2_3	CHP2_FGFR2_3	1	chr10	123274697	123274860	+	CGGCACAGGATGACTGTTACCACCATACAGGCGATTAAGAAGACCCCTATGCAGTAAATGGCTATCTCCAGGTAGTCTGGGGAAGCTGTAATCTCCTTTTCTCTTCCAGGCGCT
CHP2_FGFR2_2	CHP2_FGFR2_2	1	chr10	123279393	123279569	+	AAATCAAAGAACCTGTGGCCAAACCCATGAAGGAGACCCCAGTTGTGGGTACCTTTAGATTCAGAAAGTCCTCACCTTGAGAACCTTGAGGTAGGGCAGCCCGTCGGGCCCGTATTTACTGCCGTTC
CHP2_FGFR2_1	CHP2_FGFR2_1	1	chr10	123279583	123279738	+	TCTACGTCTCCTCCGACCACTGTGGAGGCATTTGCCGGCAGTCCGGCTTGGAGGATGGGCCGGTGAGGCGATCGCTCTGGTGGAGAGAGGGAAGAAAGGAGGAGTG
CHP2_HRAS_2	CHP2_HRAS_2	1	chr11	533788	533955	+	CACACACAGGAAGCCCTCCCCGGTGCGCATGTACTGGTCCCGCATGGCGCTGTACTCCTCCTGGCCGGCGGTATCCAGGATGTCCAACAGGCACGTCTCCCCATCAATGACCACCTGC
CHP2_HRAS_1	CHP2_HRAS_1	1	chr11	534196	534333	+	GGGGTCGTATTCGTCCACAAAATGGTTCTGGATCAGCTGGATGGTCAGCGCACTCTTGCCCACACCGCCGGCGCCCACCACCACCAGC
CHP2_ATM_1	CHP2_ATM_1	1	chr11	108117741	108117890	+	TAGGAAGTAGAGGAAAGTATTCTTCAGGATTTCGTAATATTGCCGTCAAAGAAAATTTGATTGAATTGATGGCAGATATCTGTCACCAGGTACAGTAAGT
CHP2_ATM_2	CHP2_ATM_2	1	chr11	108119791	108119916	+	GATCTTGTGCCTTGGTAAAGTGTTACCATTTTCTCATTCAGTGTCATTTTAATCTCTTGTATGTTATTTTTCAGAA
CHP2_ATM_3	CHP2_ATM_3	1	chr11	108123491	108123643	+	AAGTGAAGCTTTTTGTTTTTCTTTGTAGTAATTTTCCTCATCTTGTACTGGAGAAAATTCTTGTGAGTCTCACTATGAAAAACTGTAAAGCTGCAATGAATTT
CHP2_ATM_4	CHP2_ATM_4	1	chr11	108137907	108138050	+	AAGTAGAATCAATGGAAGATGATACTAATGGAAATCTAATGGAGGTGGAGGATCAGTCATCCATGAATCTATTTAACGATTACCCTGATAGTAG
CHP2_ATM_5	CHP2_ATM_5	1	chr11	108155059	108155205	+	AATATTCTTCCTTATTTTGCCTATGAGGGTACCAGAGACAGTGGGATGGCACAGCAAAGAGAGACTGCTACCAAGGTCTATGATATGCTTAAAAGTG
CHP2_ATM_6	CHP2_ATM_6	1	chr11	108170432	108170581	+	CTTGGGAGAAGTGGGTCCTATAGATTTCTCTACCATAGCTATACAACATAGTAAAGATGCATCTTATACCAAGGCCCTTAAGTTATTTGAAGATAAAGAA
CHP2_ATM_7	CHP2_ATM_7	1	chr11	108172338	108172492	+	TGTTTTTTTCAGTGTCAAAGTTCGATCAGCAGCTGTTACCTGTTTGAAAAACATTTTAGCCACAAAGACTGGACATAGTTTCTGGGAGATTTATAAGATGACAAC
CHP2_ATM_8	CHP2_ATM_8	1	chr11	108173606	108173728	+	GATATAAATCTGTGGATTCCTCTAAGTGAAAATCATGACATTTGGATAAAGACACTGACTTGTGCTTTTTTGG
CHP2_ATM_9	CHP2_ATM_9	1	chr11	108180878	108180985	+	ATTTTTAATGATGCTTTCTGGCTGGATTTAAATTATCTAGAAGTTGCCAAGGTAGCTC
CHP2_ATM_10	CHP2_ATM_10	1	chr11	108200891	108201018	+	TTTTACCTTAATTATTCTATGCAAGATACACAGTAAAGGTTCAGCGAGAGCTGGAGTTGGATGAATTAGCCCTGCGTG
CHP2_ATM_11	CHP2_ATM_11	1	chr11	108204610	108204709	+	CCAGCCAATTACTAAACTTAAGAATTTAGAAGATGTTGTTGTCCCTACTA
CHP2_ATM_12	CHP2_ATM_12	1	chr11	108205707	108205841	+	ATACAGTCATTTAAAGCAGAATTTCGCTTAGCAGGAGGTGTAAATTTACCAAAAATAATAGATTGTGTAGGTTCCGATGGCAAGG
CHP2_ATM_13	CHP2_ATM_13	1	chr11	108206499	108206653	+	ATAATAAAATAAACTGTACTTGTTTATTCATGCTTAATTATTCTGAAGGGCCGTGATGACCTGAGACAAGATGCTGTCATGCAACAGGTCTTCCAGATGTGTAAT
CHP2_ATM_14	CHP2_ATM_14	1	chr11	108217991	108218169	+	ACTTGGACTTGGTGATAGACATGTACAGAATATCTTGATAAATGAGCAGTCAGCAGAACTTGTACATATAGATCTAGGTAAGTAATAAAATCTATGTATCTATTCTTTTTAGTAAATATTTGGTCATCA
CHP2_ATM_15	CHP2_ATM_15	1	chr11	108225525	108225657	+	AACCATGGAAGTGATGAGAAACTCTCAGGAAACTCTGTTAACCATTGTAGAGGTAAAGTATTTTATAAGGAAGACTTTATTTT
CHP2_ATM_16	CHP2_ATM_16	1	chr11	108236018	108236165	+	TGTCCTTAGTGATATTGACCAGAGTTTCAACAAAGTAGCTGAACGTGTCTTAATGAGACTACAAGAGAAACTGAAAGGAGTGGAAGAAGGCACTGTGC
CHP2_ATM_17	CHP2_ATM_17	1	chr11	108236162	108236310	+	CCCCAAAAATCTCAGCCGACTTTTCCCAGGATGGAAAGCTTGGGTGTGATCTTCAGTATATGAATTACCCTTTCATTCAGCCTTTAGAAATTATATTTT
CHP2_KRAS_3	CHP2_KRAS_3	1	chr12	25378525	25378683	+	GTCTTGTCTTTGCTGATGTTTCAATAAAAGGAATTCCATAACTTCTTGCTAAGTCCTGAGCCTGTTTTGTGTCTACTGTTCTAGAAGGCAAATCACATTTATTTCCTAC
CHP2_KRAS_2	CHP2_KRAS_2	1	chr12	25380236	25380389	+	GCACTGTACTCCTCTTGACCTGCTGTGTCGAGAATATCCAAGAGACAGGTTTCTCCATCAATTACTACTTGCTTCCTGTAGGAATCCTGAGAAGGGAGAAACAC
CHP2_KRAS_1	CHP2_KRAS_1	1	chr12	25398162	25398329	+	GCATATTAAAACAAGATTTACCTCTATTGTTGGATCATATTCGTCCACAAAATGATTCTGAATTAGCTGTATCGTCAAGGCACTCTTGCCTACGCCACCAGCTCCAACTACCACAAGT
CHP2_PTPN11_1	CHP2_PTPN11_1	1	chr12	112888094	112888253	+	TAGAAGAAATGGAGCTGTCACCCACATCAAGATTCAGAACACTGGTGATTACTATGACCTGTATGGAGGGGAGAAATTTGCCACTTTGGCTGAGTTGGTCCAGTATTACA
CHP2_PTPN11_2	CHP2_PTPN11_2	1	chr12	112926811	112926986	+	TGCGATATTGACGTTCCCAAAACCATCCAGATGGTGCGGTCTCAGAGGTCAGGGATGGTCCAGACAGAAGCACAGTACCGATTTATCTATATGGCGGTCCAGCATTATATTGAAACACTACAGCGC
CHP2_HNF1A_1	CHP2_HNF1A_1	1	chr12	121431347	121431484	+	TGAGCTACCAACCAAGAAGGGGCGGAGGAACCGTTTCAAGTGGGGCCCAGCATCCCAGCAGATCCTGTTCCAGGCCTATGAGAGGCAG
CHP2_HNF1A_2	CHP2_HNF1A_2	1	chr12	121431986	121432124	+	GGCTGGGCTCCAACCTCGTCACGGAGGTGCGTGTCTACAACTGGTTTGCCAACCGGCGCAAAGAAGAAGCCTTCCGGCACAAGCTGGCC
CHP2_FLT3_4	CHP2_FLT3_4	1	chr13	28592555	28592688	+	ATAAGTAGGAAATAGCAGCCTCACATTGCCCCTGACAACATAGTTGGAATCACTCATGATATCTCGAGCCAATCCAAAGTCACA
CHP2_FLT3_3	CHP2_FLT3_3	1	chr13	28602251	28602404	+	AGTCTTTTTGATGAGGTGATTTTCGTGGAAGTGGGTTACCTGACAGTGTGCACGCCCCCAGCAGGTTCACAATATTCTCGTGGCTTCCCAGCTGGGTCATCATC
CHP2_FLT3_2	CHP2_FLT3_2	1	chr13	28608203	28608373	+	AATTTTCTCTTGGAAACTCCCATTTGAGATCATATTCATATTCTCTGAAATCAACGTAGAAGTACTCATTATCTGAGGAGCCGGTCACCTGTACCATCTGTAGCTGGCTTTCATACCTAAA
CHP2_FLT3_1	CHP2_FLT3_1	1	chr13	28610069	28610209	+	TCTTCCAGGTCCAAGATGGTAATGGGTATCCATCCGAGAAACAGGACGCCTGACTTGCCGATGCTTCTGCGAGCACTTGAGGTTTCCCTAT
CHP2_RB1_1	CHP2_RB1_1	1	chr13	48919199	48919337	+	AATTCTTTAACTTACTAAAAGAAATTGATACCAGTACCAAAGTTGATAATGCTATGTCAAGACTGTTGAAGAAGTATGATGTATTGTTT
CHP2_RB1_2	CHP2_RB1_2	1	chr13	48923115	48923280	+	CACATTTTTATTAGCTAAAGGTAAGTTCATTATATTTATTAAATGCTAATATTTCAAATGTAATAATTAAATTGGCATTCCTTTGGACTAAATTCCCCAATTTTTATTGAGTAATG
CHP2_RB1_3	CHP2_RB1_3	1	chr13	48941577	48941749	+	TAATTGTCAGTGACTTTTTTCTTTCAAGGTTGAAAATCTTTCTAAACGATACGAAGAAATTTATCTTAAAAATAAAGATCTAGATGCAAGATTATTTTTGGATCATGATAAAACTCTTCAGAC
CHP2_RB1_4	CHP2_RB1_4	1	chr13	48942573	48942736	+	TTTGATGCATAAAGCACAAATTGTAAATTTTCAGTATGTGAATGACTTCACTTATTGTTATTTAGTTTTGAAACACAGAGAACACCACGAAAAAGTAACCTTGATGAAGAGGTG
CHP2_RB1_5	CHP2_RB1_5	1	chr13	48953729	48953899	+	TATTACCGAGTAATGGAATCCATGCTTAAATCAGTAAGTTAAAAACAATATAAAAAAATTTCAGCCGGGCGCGGTGGCTCACGCCTGCAATCCCAGCACTTTGGGAGGCCGAGGTGGGCAG
CHP2_RB1_6	CHP2_RB1_6	1	chr13	48955501	48955630	+	AAACATTTAGAACGATGTGAACATCGAATCATGGAATCCCTTGCATGGCTCTCAGTAAGTAGCTAAATAATTGAAGAAAT
CHP2_RB1_7	CHP2_RB1_7	1	chr13	49027081	49027203	+	TAATTTCATCATGTTTCATATAGGATTCACCTTTATTTGATCTTATTAAACAATCAAAGGACCGAGAAGGACC
CHP2_RB1_8	CHP2_RB1_8	1	chr13	49033803	49033959	+	TCGGCTAGCCTATCTCCGGCTAAATACACTTTGTGAACGCCTTCTGTCTGAGCACCCAGAATTAGAACATATCATCTGGACCCTTTTCCAGCACACCCTGCAGAATG
CHP2_RB1_9	CHP2_RB1_9	1	chr13	49037822	49037957	+	TACATCAATTTATTTACTAGATTATGATGTGTTCCATGTATGGCATATGCAAAGTGAAGAATATAGACCTTAAATTCAAAATCATT
CHP2_RB1_10	CHP2_RB1_10	1	chr13	49039125	49039257	+	TGATCAAAGAAGAGGAGTATGATTCTATTATAGTATTCTATAACTCGGTCTTCATGCAGAGACTGAAAACAAATATTTTGCAG
CHP2_AKT1_2	CHP2_AKT1_2	1	chr14	105241409	105241544	+	CTTGAGGATCTTCATGGCGTAGTAGCGGCCTGTGGCCTTCTCCTTCACCAGGATCACCTTGCCGAAAGTGCCCTTGCCCAGCAGCT
CHP2_AKT1_1	CHP2_AKT1_1	1	chr14	105246421	105246608	+	GGGGAGCCTCACGTTGGTCCACATCCTGCGGCCGCTCCTTGTAGCCAATGAAGGTGCCATCATTCTTGAGGAGGAAGTAGCGTGGCCGCCAGGTCTTGATGTACTCCCCTACAGACGTGCGGGTGGTGAGAGCCACGC
CHP2_IDH2_1	CHP2_IDH2_1	1	chr15	90631800	90631979	+	GCCATGGGCGTGCCTGCCAATGGTGATGGGCTTGGTCCAGCCAGGGACTAGGCGTGGGATGTTTTTGCAGATGATGGGCTCCCGGAAGACAGTCCCCCCCAGGATGTTCCGGATAGTTCCATTGGGACTT
CHP2_CDH1_1	CHP2_CDH1_1	1	chr16	68835578	68835722	+	GGACAGCCTATTTTTCCCTCGACACCCGATTCAAAGTGGGCACAGATGGTGTGATTACAGTCAAAAGGCCTCTACGGTTTCATAACCCACAGATC
CHP2_CDH1_2	CHP2_CDH1_2	1	chr16	68846000	68846176	+	GATCTCTCTGCAGAGTTTCCCTACGTATACCCTGGTGGTTCAAGCTGCTGACCTTCAAGGTGAGGGGTTAAGCACAACAGCAACAGCTGTGATCACAGTCACTGACACCAACGATAATCCTCCGATC
CHP2_CDH1_3	CHP2_CDH1_3	1	chr16	68847175	68847327	+	TCTCTTTGCTCTGCAGTACAAGGGTCAGGTGCCTGAGAACGAGGCTAACGTCGTAATCACCACACTGAAAGTGACTGATGCTGATGCCCCCAATACCCCAGCG
CHP2_TP53_8	CHP2_TP53_8	1	chr17	7573899	7574060	+	CACCTGGAGTGAGCCCTGCTCCCCCCTGGCTCCTTCCCAGCCTGGGCATCCTTGAGTTCCAAGGCCTCATTCAGCTCTCGGAACATCTCGAAGCGCTCACGCCCACGGATCT
CHP2_TP53_7	CHP2_TP53_7	1	chr17	7576991	7577176	+	TACCTCGCTTAGTGCTCCCTGGGGGCAGCTCGTGGTGAGGCTCCCCTTTCTTGCGGAGATTCTCTTCCTCTGTGCGCCGGTCTCTCCCAGGACAGGCACAAACACGCACCTCAAAGCTGTTCCGTCCCAGTAGATT
CHP2_TP53_6	CHP2_TP53_6	1	chr17	7577484	7577637	+	CCAGTGTGATGATGGTGAGGATGGGCCTCCGGTTCATGCCGCCCATGCAGGAACTGTTACACATGTAGTTGTAGTGGATGGTGGTACAGTCAGAGCCAACCTAG
CHP2_TP53_5	CHP2_TP53_5	1	chr17	7578156	7578323	+	GGCGGCTCATAGGGCACCACCACACTATGTCGAAAAGTGTTTCTGTCATCCAAATACTCCACACGCAAATTTCCTTCCACTCGGATAAGATGCTGAGGAGGGGCCAGACCTAAGAGCA
CHP2_TP53_4	CHP2_TP53_4	1	chr17	7578328	7578508	+	CCAGCCCCAGCTGCTCACCATCGCTATCTGAGCAGCGCTCATGGTGGGGGCAGCGCCTCACAACCTCCGTCATGTGCTGTGACTGCTTGTAGATGGCCATGGCGCGGACGCGGGTGCCGGGCGGGGGTGTG
CHP2_TP53_3	CHP2_TP53_3	1	chr17	7578492	7578626	+	GCCAGTTGGCAAAACATCTTGTTGAGGGCAGGGGAGTACTGTAGGAAGAGGAAGGAGACAGAGTTGAAAGTCAGGGCACAAGTGA
CHP2_TP53_2	CHP2_TP53_2	1	chr17	7579326	7579510	+	GCCCAGACGGAAACCGTAGCTGCCCTGGTAGGTTTTCTGGGAAGGGACAGAAGATGACAGGGGCCAGGAGGGGGCTGGTGCAGGGGCCGCCGGTGTAGGAGCTGCTGGTGCAGGGGCCACGGGGGGAGCAGCCTC
CHP2_TP53_1	CHP2_TP53_1	1	chr17	7579829	7579985	+	GAAAATGTTTCCTGACTCAGAGGGGGCTCGACGCTAGGATCTGACTGCGGCTCCTCCATGGCAGTGACCCGGAAGGCAGTCTGGCTGCTGCAAGAGGAAAAGTGGGG
CHP2_ERBB2_1	CHP2_ERBB2_1	1	chr17	37880188	37880365	+	AAAGTGTTGAGGGAAAACACATCCCCCAAAGCCAACAAAGAAATCTTAGACGTAAGCCCCTCCACCCTCTCCTGCTAGGAGGACAGGAAGGACCCCATGGCTGCAGGTCTGGGCTCTGGTCTCTCTTC
CHP2_ERBB2_2	CHP2_ERBB2_2	1	chr17	37880929	37881086	+	CCTCTCAGCGTACCCTTGTCCCCAGGAAGCATACGTGATGGCTGGTGTGGGCTCCCCATATGTCTCCCGCCTTCTGGGCATCTGCCTGACATCCACGGTGCAGCTGGT
CHP2_ERBB2_3	CHP2_ERBB2_3	1	chr17	37881300	37881478	+	GCGGCTCGTACACAGGGACTTGGCCGCTCGGAACGTGCTGGTCAAGAGTCCCAACCATGTCAAAATTACAGACTTCGGGCTGGCTCGGCTGCTGGACATTGACGAGACAGAGTACCATGCAGATGGGGG
CHP2_SMAD4_1	CHP2_SMAD4_1	1	chr18	48575075	48575238	+	CTGGAGGTGGCCTGATCTTCACAAAAATGAACTAAAACATGTTAAATATTGTCAGTATGCGTTTGACTTAAAATGTGATAGTGTCTGTGTGAATCCATATCACTACGAACGAGT
CHP2_SMAD4_2	CHP2_SMAD4_2	1	chr18	48575532	48575702	+	TGAACTTTTGTAATCTTTGGTTTAAATTTACATTCTCTGTTTTTAAATGGAAAATACTTTCATTGTAATGATTAATGTTTCATTTGTTTTCCCCTTTAAACAATTAAGATCTCTCAGGATT
CHP2_SMAD4_3	CHP2_SMAD4_3	1	chr18	48581166	48581327	+	CTTTGAGGGACAGCCATCGTTGTCCACTGAAGGACATTCAATTCAAACCATCCAGCATCCACCAAGTAATCGTGCATCGACAGAGACATACAGCACCCCAGCTCTGTTAGCC
CHP2_SMAD4_4	CHP2_SMAD4_4	1	chr18	48584527	48584703	+	CAGGGCCTCAGCCAGGACAGCAGCAGAATGGATTTACTGGTCAGCCAGCTACTTACCATCATAGTATGTACATACTTTAAAAAATCTTTTAAATAGTTGAGAAAAAAGTAGGCAGCCTTTATAAAAG
CHP2_SMAD4_5	CHP2_SMAD4_5	1	chr18	48586227	48586386	+	GCTTGCATTCCAGCCTCCCATTTCCAATCATCCTGGTAAGTGTATTTCAAAATTGATTTCCTGTATTTAGATTGATTTAGTGGTGATTGAAACGCACAAACACAGGCTTT
CHP2_SMAD4_6	CHP2_SMAD4_6	1	chr18	48591790	48591956	+	TGCTTACTTTGAAATGGATGTTCAGGTAGGAGAGACATTTAAGGTTCCTTCAAGCTGCCCTATTGTTACTGTTGATGGATACGTGGACCCTTCTGGAGGAGATCGCTTTTGTTTGGG
CHP2_SMAD4_7	CHP2_SMAD4_7	1	chr18	48593375	48593544	+	GCAAAGGTGTGCAGTTGGAATGTAAAGGTGAAGGTGATGTTTGGGTCAGGTGCCTTAGTGACCACGCGGTCTTTGTACAGAGTTACTACTTAGACAGAGAAGCTGGGCGTGCACCTGGAG
CHP2_SMAD4_8	CHP2_SMAD4_8	1	chr18	48603004	48603144	+	CATCGACAGATGCAGCAGCAGGCGGCTACTGCACAAGCTGCAGCAGCTGCCCAGGCAGCAGCCGTGGCAGGAAACATCCCTGGCCCAGGAT
CHP2_SMAD4_9	CHP2_SMAD4_9	1	chr18	48604634	48604799	+	ACCTTCGTCGCTTATGCATACTCAGGATGAGTTTTGTGAAAGGCTGGGGACCGGATTACCCAAGACAGAGCATCAAAGAAACACCTTGCTGGATTGAAATTCACTTACACCGGGCC
CHP2_STK11_1	CHP2_STK11_1	1	chr19	1206953	1207129	+	GGACACGTTCATCCACCGCATCGACTCCACCGAGGTCATCTACCAGCCGCGCCGCAAGCGGGCCAAGCTCATCGGCAAGTACCTGATGGGGGACCTGCTGGGGGAAGGCTCTTACGGCAAGGTGAAG
CHP2_STK11_2	CHP2_STK11_2	1	chr19	1220286	1220475	+	AGGGGACCCCTGTGAGGGGCAGGGAGGCCTCGGCCCCAGGACGGGTGTGTGCTGCCCGCAGGTACTTCTGTCAGCTGATTGACGGCCTGGAGTACCTGCATAGCCAGGGCATTGTGCACAAGGACATCAAGCCGGGGAAC
CHP2_STK11_3	CHP2_STK11_3	1	chr19	1220456	1220628	+	ATCTCCGACCTGGGCGTGGCCGAGGTAGGCACGTGCTAGGGGGGGCCCTGGGGCGCCCCCTCCCGGGCACTCCCTGAGGGCTGCACGGCACCGCCACAGGCACTGCACCCGTTCGCGGCGGAC
CHP2_STK11_4	CHP2_STK11_4	1	chr19	1221212	1221357	+	CCCTTCGAAGGGGACAACATCTACAAGTTGTTTGAGAACATCGGGAAGGGGAGCTACGCCATCCCGGGCGACTGTGGCCCCCCGCTCTCTGACCTG
CHP2_STK11_5	CHP2_STK11_5	1	chr19	1222990	1223169	+	GCACCAGTGCCCATCCCACCGAGCCCAGACACCAAGGACCGGTGGCGCAGCATGACTGTGGTGCCGTACTTGGAGGACCTGCACGGCGCGGACGAGGACGAGGACCTCTTCGACATCGAGGATGACATCA
CHP2_GNA11_1	CHP2_GNA11_1	1	chr19	3118857	3118998	+	GGGCGCCAGGTGGCTGAGTCCTGGCGCTGTGTCCTTTCAGGATGGTGGATGTGGGGGGCCAGCGGTCGGAGCGGAGGAAGTGGATCCACTGC
CHP2_JAK3_3	CHP2_JAK3_3	1	chr19	17945592	17945759	+	CAAAGTGGGGGTTCGGAGACCGATGCCGGGTGAGGGGCTCTGACCTTAGCAGGATCCAGGGCACTGATGGGCATGGTGACGCCACTAAACACTTCCCAGACCGTGGCGCCGAAGCCCC
CHP2_JAK3_2	CHP2_JAK3_2	1	chr19	17947962	17948099	+	CACTTGGCTCATCAAGCTCGCTGCTTCCAGGAATGACTGGGGAAGGTGGGAAGGGAGAGAAGATGCGTGGGTTTCTTCCACTCCAATA
CHP2_JAK3_1	CHP2_JAK3_1	1	chr19	17954110	17954250	+	ATGTTGCCCCTTGGACCCCCAACCCCCTGGGTCAAACCCCAGGCAGAACCCCACCTGGGCAAAGAGGTGCTCCAGGACTGGCAGGTCAAGG
CHP2_SRC_1	CHP2_SRC_1	1	chr20	36031642	36031794	+	GCCAGTGCTGGCGGAAGGAGCCTGAGGAGCGGCCCACCTTCGAGTACCTGCAGGCCTTCCTGGAGGACTACTTCACGTCCACCGAGCCCCAGTACCAGCCCGG
CHP2_GNAS_1	CHP2_GNAS_1	1	chr20	57484372	57484529	+	TGTTTCAGGACCTGCTTCGCTGCCGTGTCCTGACTTCTGGAATCTTTGAGACCAAGTTCCAGGTGGACAAAGTCAACTTCCAGTAAGCCAACTGTTACCTTTTTATAT
CHP2_GNAS_2	CHP2_GNAS_2	1	chr20	57484538	57484697	+	TCCTCCCCACCAGCATGTTTGACGTGGGTGGCCAGCGCGATGAACGCCGCAAGTGGATCCAGTGCTTCAACGGTAGGATGCTGTGGGCTTGGCTGTTCGTAAAGAACGCT
CHP2_SMARCB1_1	CHP2_SMARCB1_1	1	chr22	24133929	24134089	+	CCTCCGTATGTTCCGAGGTTCTCTGTACAAGAGATACCCCTCACTCTGGAGGCGACTAGCCACTGTGGAAGAGAGGAAGAAAATAGTTGCATCGTCACATGGTAAAAAAAC
CHP2_SMARCB1_2	CHP2_SMARCB1_2	1	chr22	24143176	24143336	+	GTGCCATGCTCCACAACCATCAACAGGAACCGCATGGGCCGAGACAAGAAGAGAACCTTCCCCCTTTGGTGTGGATGCATCGCTGCACTCACCCTCCGTGCTGATTCCGCC
CHP2_SMARCB1_3	CHP2_SMARCB1_3	1	chr22	24145453	24145623	+	TCAGCTTTGATGACCATGACCCAGCTGTGATCCATGAGAACGCATCTCAGCCCGAGGTGCTGGTCCCCATCCGGCTGGACATGGAGATCGATGGGCAGAAGCTGCGAGACGCCTTCACCTG
CHP2_SMARCB1_4	CHP2_SMARCB1_4	1	chr22	24176235	24176416	+	CCTTGGGAAGGGCAGCGCCCAGGCTGGGAGCTGGCCCCGACTCATTGCCCTCCCCACTCCTCTTCCAGGCGGATGAGGCGTCTTGCCAACACGGCCCCGGCCTGGTAACCAGCCCATCAGCACACGGCTCCC

