Name Chr MapInfo Alleles Transcript(s) Gene(s) In-exon Mutation(s) rs13125929 4 71566 [T/C] NM_001286054,NM_001286053,NM_001286052,NM_182524,NR_110527,NM_001039127,NM_001289931 ZNF595,ZNF595,ZNF595,ZNF595,ZNF718,ZNF718,ZNF718 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13148549 4 74983 [T/G] NM_001286054,NM_001286053,NM_001286052,NM_182524,NR_110527,NM_001039127,NM_001289931 ZNF595,ZNF595,ZNF595,ZNF595,ZNF718,ZNF718,ZNF718 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12511220 4 75174 [T/C] NM_001286054,NM_001286053,NM_001286052,NM_182524,NR_110527,NM_001039127,NM_001289931 ZNF595,ZNF595,ZNF595,ZNF595,ZNF718,ZNF718,ZNF718 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7667153 4 85422 [A/G] NM_001286054,NM_001286053,NM_001286052,NM_182524,NR_110527,NM_001039127,NM_001289931 ZNF595,ZNF595,ZNF595,ZNF595,ZNF718,ZNF718,ZNF718 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10002444 4 99926 [A/G] NR_110527,NM_001039127,NM_001289931 ZNF718,ZNF718,ZNF718 Silent,Silent,Silent rs6819316 4 109596 [A/G] NR_110527,NM_001039127,NM_001289931 ZNF718,ZNF718,ZNF718 Silent,Silent,Silent rs17802159 4 111487 [A/G] NR_110527,NM_001039127,NM_001289931 ZNF718,ZNF718,ZNF718 Silent,Silent,Silent rs7699689 4 127452 [A/G] NR_110527,NM_001039127,NM_001289931,NR_110528,NM_001289930,NR_110529 ZNF718,ZNF718,ZNF718,ZNF718,ZNF718,ZNF718 Silent,Silent,Silent,Silent,Silent,Silent rs3829 4 134851 [T/C] NR_110527,NM_001039127,NM_001289931,NR_110528,NM_001289930,NR_110529 ZNF718,ZNF718,ZNF718,ZNF718,ZNF718,ZNF718 Silent,Silent,Silent,Silent,Silent,Silent rs6830247 4 150683 [A/G] NR_110527,NM_001039127,NM_001289931,NR_110528,NM_001289930,NR_110529 ZNF718,ZNF718,ZNF718,ZNF718,ZNF718,ZNF718 Silent,Silent,Silent,Silent,Silent,Silent rs12108398 4 171534 [A/G] NR_110527,NR_110528 ZNF718,ZNF718 Silent,Silent rs11731927 4 174105 [A/G] NR_110527,NR_110528 ZNF718,ZNF718 Silent,Silent rs7665922 4 181476 [T/C] NR_110527,NR_110528 ZNF718,ZNF718 Silent,Silent rs6817633 4 181832 [A/G] NR_110527,NR_110528 ZNF718,ZNF718 Silent,Silent rs28716466 4 201074 [T/C] rs13124826 4 208400 [A/G] NR_027481 ZNF876P Silent rs4690243 4 215351 [T/C] NR_027481 ZNF876P Silent rs2353605 4 219538 [T/C] NR_027481 ZNF876P Silent rs7695945 4 221623 [A/C] NR_027481 ZNF876P Silent rs17521834 4 225449 [A/G] NR_027481 ZNF876P Silent rs10010286 4 262062 [A/C] rs11731285 4 264941 [A/G] NM_001137608 ZNF732 EXON Missense_W569R rs10002733 4 279396 [A/C] NM_001137608 ZNF732 Silent rs11723261 4 282499 [A/G] NM_001137608 ZNF732 Silent rs1986557 4 283118 [T/C] NM_001137608 ZNF732 Silent rs11723803 4 292369 [T/G] NM_001137608 ZNF732 Silent rs2352927 4 297932 [T/C] NM_001137608 ZNF732 Silent rs10034550 4 305291 [A/G] rs6848983 4 308010 [T/G] rs6847267 4 315673 [T/C] rs11946825 4 321902 [T/C] rs7677824 4 331372 [T/C] rs11729526 4 333310 [A/G] NM_001348277,NM_003441,NM_001348279,NM_001348280,NM_001348278 ZNF141,ZNF141,ZNF141,ZNF141,ZNF141 Silent,Silent,Silent,Silent,Silent rs6825544 4 350579 [A/G] NM_001348277,NM_003441,NM_001348279,NM_001348280,NM_001348278 ZNF141,ZNF141,ZNF141,ZNF141,ZNF141 Silent,Silent,Silent,Silent,Silent rs11725919 4 364537 [T/G] NM_001348277,NM_003441,NM_001348278 ZNF141,ZNF141,ZNF141 Silent,Silent,Silent rs3946 4 367927 [A/G] NM_001348277,NM_003441,NM_001348278 ZNF141,ZNF141,ZNF141 EXON Silent,Silent,Silent rs11735858 4 375698 [T/C] NM_001348277,NM_003441,NM_001348278 ZNF141,ZNF141,ZNF141 EXON Silent,Silent,Silent rs11934905 4 386697 [T/C] rs6838825 4 410015 [A/G] rs7695712 4 415311 [A/G] rs17164836 4 427376 [T/C] NR_002451 ABCA11P Silent rs11248018 4 430221 [T/C] NR_002451 ABCA11P Silent rs35036867 4 432766 [A/C] NR_002451 ABCA11P Silent rs11944122 4 442021 [T/C] NR_002451,NM_133474 ABCA11P,ZNF721 Silent,Silent rs11947207 4 445794 [A/G] NR_002451,NM_133474 ABCA11P,ZNF721 Silent,Silent rs12186156 4 452106 [T/C] NR_002451,NM_133474 ABCA11P,ZNF721 Silent,Silent rs6810900 4 470866 [T/C] NM_133474 ZNF721 Silent rs6599351 4 473952 [A/G] NM_133474 ZNF721 Silent rs9994908 4 492129 [A/G] NM_133474 ZNF721 Silent rs7695915 4 497138 [T/G] NM_001289057,NM_001127178,NM_001289052,NM_001289055,NM_001345988,NR_144327,NM_001345994,NM_001345986,NM_001289053,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345989,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17721347 4 498459 [T/C] NM_001289057,NM_001127178,NM_001289052,NM_001289055,NM_001345988,NR_144327,NM_001345994,NM_001345986,NM_001289053,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345989,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17721401 4 500500 [T/C] NM_001289057,NM_001127178,NM_001289052,NM_001289055,NM_001345988,NR_144327,NM_001345994,NM_001345986,NM_001289053,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345989,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7659929 4 501473 [A/C] NM_001289057,NM_001127178,NM_001289052,NM_001289055,NM_001345988,NR_144327,NM_001345994,NM_001345986,NM_001289053,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345989,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17164861 4 502911 [T/C] NM_001289057,NM_001127178,NM_001289052,NM_001289055,NM_001345988,NR_144327,NM_001345994,NM_001345986,NM_001289053,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345989,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1867188 4 504012 [T/G] NM_001289057,NM_001127178,NM_001289052,NM_001289055,NM_001345988,NR_144327,NM_001345994,NM_001345986,NM_001289053,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345989,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11726338 4 509850 [T/C] NM_001289057,NM_001127178,NM_001289052,NM_001289055,NM_001345988,NR_144327,NM_001345994,NM_001345986,NM_001289053,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345989,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG EXON Synonymous_S241S,Synonymous_S330S,Synonymous_S197S,Synonymous_S208S,Silent,Silent,Silent,Synonymous_S241S,Synonymous_S241S,Silent,Silent,Silent,Silent,Silent,Silent,Synonymous_S241S,Synonymous_S330S,Silent,Synonymous_S330S,Synonymous_S241S,Silent,Silent,Silent,Silent rs11730564 4 514201 [T/G] NM_001289057,NM_001127178,NM_001289052,NM_001289055,NM_001345988,NR_144327,NM_001345994,NM_001345986,NM_001289053,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345989,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10029104 4 514629 [A/G] NM_001289057,NM_001127178,NM_001289052,NM_001289055,NM_001345988,NR_144327,NM_001345994,NM_001345986,NM_001289053,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345989,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13115344 4 515489 [A/G] NM_001289057,NM_001127178,NM_001289052,NM_001289055,NM_001345988,NR_144327,NM_001345994,NM_001345986,NM_001289053,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345989,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG EXON Synonymous_A296A,Missense_R458H,Missense_R325H,Missense_A321T,Missense_R115H,Silent,Missense_R92H,Missense_R369H,Missense_R369H,Silent,Silent,Silent,Silent,Silent,Silent,Missense_R369H,Missense_R458H,Silent,Missense_R450H,Missense_R361H,Silent,Silent,Silent,Silent rs7672868 4 516398 [A/G] NM_001289057,NM_001127178,NM_001289052,NM_001289055,NM_001345988,NR_144327,NM_001345994,NM_001345986,NM_001289053,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345989,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1135945 4 516586 [A/G] NM_001289057,NM_001127178,NM_001289052,NM_001289055,NM_001345988,NR_144327,NM_001345994,NM_001345986,NM_001289053,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345989,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7666226 4 517376 [T/C] NM_001127178,NM_001289052,NM_001345988,NR_144327,NM_001345994,NM_001345986,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG EXON Synonymous_L581L,Synonymous_L448L,Synonymous_L238L,Silent,Synonymous_L215L,Synonymous_L492L,Silent,Silent,Silent,Silent,Silent,Silent,Synonymous_L492L,Synonymous_L70L,Synonymous_L573L,Synonymous_L484L,Silent,Silent,Synonymous_L70L,Silent rs7666425 4 517461 [T/C] NM_001127178,NM_001289052,NM_001345988,NR_144327,NM_001345994,NM_001345986,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG EXON Missense_C610R,Missense_C477R,Missense_C267R,Silent,Missense_C244R,Missense_C521R,Silent,Silent,Silent,Silent,Silent,Silent,Missense_C521R,Missense_C99R,Missense_C602R,Missense_C513R,Silent,Silent,Missense_C99R,Silent rs13150531 4 517622 [T/C] NM_001127178,NM_001289052,NM_001345988,NR_144327,NM_001345994,NM_001345986,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG EXON Synonymous_A663A,Synonymous_A530A,Synonymous_A320A,Silent,Synonymous_A297A,Synonymous_A574A,Silent,Silent,Silent,Silent,Silent,Silent,Synonymous_A574A,Synonymous_A152A,Synonymous_A655A,Synonymous_A566A,Silent,Silent,Synonymous_A152A,Silent rs4624610 4 521480 [T/C] NM_001127178,NM_001289052,NM_001345988,NR_144327,NM_001345994,NM_001345986,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10213007 4 532200 [A/G] NM_001127178,NM_001289052,NM_001345988,NR_144327,NM_001345994,NM_001345986,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1127410 4 533001 [T/C] NM_001127178,NM_001289052,NM_001345988,NR_144327,NM_001345994,NM_001345986,NR_144328,NR_144330,NR_144332,NR_144333,NR_144334,NR_144331,NM_001289051,NM_001345990,NM_017733,NM_001345987,NR_144326,NR_144329,NM_001345991,NR_110293 PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG,PIGG EXON Missense_F932S,Missense_F799S,Missense_F589S,Silent,Missense_F566S,Missense_F843S,Silent,Silent,Silent,Silent,Silent,Silent,Missense_F843S,Missense_F421S,Missense_F924S,Missense_F835S,Silent,Silent,Missense_F421S,Silent rs13149565 4 540025 [T/C] rs6822767 4 540099 [T/C] rs10014828 4 541182 [T/C] rs7655590 4 561631 [A/G] rs10018393 4 575087 [T/G] NR_148199 LOC105374338 Silent rs35158410 4 583559 [A/C] rs34587191 4 592507 [A/G] rs7661376 4 594372 [T/C] rs9884240 4 607202 [T/C] rs7665160 4 611204 [A/G] rs10027392 4 618477 [A/G] rs10029928 4 624897 [A/G] NM_001145291,NM_000283 PDE6B,PDE6B Silent,Silent rs34953355 4 630192 [T/C] NM_001145291,NM_000283 PDE6B,PDE6B Silent,Silent rs10031745 4 639670 [T/C] NM_001145291,NM_000283 PDE6B,PDE6B Silent,Silent rs10010598 4 640165 [T/C] NM_001145291,NM_000283 PDE6B,PDE6B Silent,Silent rs10027866 4 644438 [A/G] NM_001145291,NM_000283 PDE6B,PDE6B Silent,Silent rs3864130 4 646409 [T/G] NM_001145291,NM_000283 PDE6B,PDE6B Silent,Silent rs10902758 4 648643 [A/G] NM_001145291,NM_000283,NM_001350154,NM_001145292,NM_001350155 PDE6B,PDE6B,PDE6B,PDE6B,PDE6B EXON Missense_V320I,Missense_V320I,Missense_V41I,Missense_V41I,Silent rs7436737 4 658089 [A/G] NM_001145291,NM_000283,NM_001350154,NM_001145292,NM_001350155 PDE6B,PDE6B,PDE6B,PDE6B,PDE6B Silent,Silent,Silent,Silent,Silent rs28675771 4 663908 [A/G] NM_001145291,NM_000283,NM_001350154,NM_001145292,NM_001350155 PDE6B,PDE6B,PDE6B,PDE6B,PDE6B EXON Silent,Silent,Missense_M559V,Silent,Missense_M453V rs28470912 4 665737 [T/C] rs13104878 4 666057 [T/C] rs4463020 4 666212 [T/G] rs28531889 4 672681 [A/G] NM_001363650,NM_002477 MYL5,MYL5 Silent,Silent rs10020292 4 681778 [A/G] NM_001294342,NM_001294341,NM_032219 SLC49A3,SLC49A3,SLC49A3 Silent,Silent,Silent rs9991613 4 681940 [T/C] NM_001294342,NM_001294341,NM_032219 SLC49A3,SLC49A3,SLC49A3 Silent,Silent,Silent rs28510755 4 682233 [A/C] NM_001294342,NM_001294341,NM_032219 SLC49A3,SLC49A3,SLC49A3 Silent,Silent,Silent rs10026699 4 683842 [A/G] rs35466919 4 685993 [A/G] rs6857009 4 691026 [A/G] rs11730652 4 694613 [T/C] rs6837180 4 698292 [A/G] rs4690187 4 703813 [T/C] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs4076064 4 712222 [T/C] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs10452329 4 716248 [T/C] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs10034650 4 726322 [A/G] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs4690296 4 732261 [A/G] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs11729193 4 734351 [A/G] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs747504 4 734677 [A/G] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs4234853 4 735150 [A/G] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs9332466 4 744098 [T/C] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs1531583 4 744972 [T/G] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs17164972 4 747810 [T/C] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs4690304 4 748447 [A/G] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs4690281 4 753944 [A/G] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs2242233 4 755025 [A/G] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs2242235 4 755210 [A/G] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs4690309 4 756377 [T/C] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs6838241 4 756686 [A/C] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs13138362 4 756986 [T/C] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs6815857 4 759374 [T/C] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs6810428 4 759709 [A/G] NM_001317836,NM_006315 PCGF3,PCGF3 Silent,Silent rs7336 4 760258 [T/G] NM_001317836,NM_006315 PCGF3,PCGF3 EXON Silent,Silent rs4690194 4 760819 [T/C] NM_001317836,NM_006315 PCGF3,PCGF3 EXON Silent,Silent rs1044147 4 763077 [A/G] NM_001317836,NM_006315 PCGF3,PCGF3 EXON Silent,Silent rs7340883 4 779077 [T/G] NM_006651 CPLX1 EXON Silent rs2242237 4 779394 [A/G] NM_006651 CPLX1 EXON Silent rs6816868 4 779670 [T/C] NM_006651 CPLX1 EXON Silent rs3822028 4 785041 [T/C] NM_006651 CPLX1 Silent rs2306251 4 786401 [T/C] NM_006651 CPLX1 Silent rs11722977 4 790757 [A/C] NM_006651 CPLX1 Silent rs6599377 4 790889 [T/G] NM_006651 CPLX1 Silent rs10004297 4 793763 [T/C] NM_006651 CPLX1 Silent rs10004503 4 793929 [T/C] NM_006651 CPLX1 Silent rs7677766 4 795890 [A/G] NM_006651 CPLX1 Silent rs17165026 4 798511 [T/C] NM_006651 CPLX1 Silent rs17165034 4 798962 [A/G] NM_006651 CPLX1 Silent rs9328757 4 809593 [A/G] NM_006651 CPLX1 Silent rs9328758 4 809787 [T/C] NM_006651 CPLX1 Silent rs11248043 4 812753 [A/G] NM_006651 CPLX1 Silent rs17165046 4 813393 [T/C] NM_006651 CPLX1 Silent rs7376690 4 813726 [A/G] NM_006651 CPLX1 Silent rs6832751 4 814080 [A/G] NM_006651 CPLX1 Silent rs10155282 4 814719 [A/G] NM_006651 CPLX1 Silent rs936551 4 821490 [A/G] rs4690321 4 832610 [T/C] rs6964 4 843184 [A/G] NM_005255,NM_001318134 GAK,GAK EXON Silent,Silent rs8093 4 843695 [A/G] NM_005255,NM_001318134 GAK,GAK EXON Synonymous_A1273A,Synonymous_A1194A rs2306242 4 843720 [T/C] NM_005255,NM_001318134 GAK,GAK EXON Missense_K1265R,Missense_K1186R rs4690340 4 848280 [T/G] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs4690339 4 854712 [T/C] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs2306248 4 860146 [A/G] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs2306247 4 860349 [A/G] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs3733351 4 861628 [T/C] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs2306245 4 862156 [T/C] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs7690704 4 864126 [A/G] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs755447 4 865227 [A/G] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs764324 4 867866 [T/C] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs1564280 4 871675 [A/G] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs2279186 4 875887 [A/G] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs11736181 4 877412 [T/C] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs11946340 4 878079 [T/C] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs17781348 4 878746 [A/G] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs17781378 4 880094 [T/C] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs2279181 4 882643 [A/G] NM_005255,NM_001318134 GAK,GAK EXON Synonymous_S399S,Synonymous_S320S rs2279180 4 883039 [A/G] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs3775127 4 886061 [A/G] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs11726508 4 888937 [T/C] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs9994159 4 891150 [T/C] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs2306252 4 892116 [T/C] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs3775122 4 893287 [A/G] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs3755963 4 894255 [A/G] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs3822023 4 896486 [T/C] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs17165156 4 899143 [A/G] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs754758 4 924280 [A/C] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs873785 4 925149 [T/C] NM_005255,NM_001318134 GAK,GAK Silent,Silent rs28525059 4 926245 [A/G] NM_001297424,NM_001297426,NM_001297427,NM_001297425,NM_001297428,NM_001297423,NM_032326 TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs935965 4 928684 [T/C] NM_001297424,NM_001297426,NM_001297427,NM_001297425,NM_001297428,NM_001297423,NM_032326 TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17165165 4 939404 [A/G] NM_001297424,NM_001297426,NM_001297427,NM_001297425,NM_001297428,NM_001297423,NM_032326 TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7687129 4 939883 [T/C] NM_001297424,NM_001297426,NM_001297427,NM_001297425,NM_001297428,NM_001297423,NM_032326 TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6815138 4 941290 [A/C] NM_001297424,NM_001297426,NM_001297427,NM_001297425,NM_001297428,NM_001297423,NM_032326 TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10516158 4 942439 [T/C] NM_001297424,NM_001297426,NM_001297427,NM_001297425,NM_001297428,NM_001297423,NM_032326 TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2290405 4 946974 [A/G] NM_001297424,NM_001297426,NM_001297427,NM_001297425,NM_001297428,NM_001297423,NM_032326 TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1051613 4 951179 [A/G] NM_001297424,NM_001297426,NM_001297427,NM_001297425,NM_001297428,NM_001297423,NM_032326 TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs748483 4 952409 [A/G] NM_001297424,NM_001297426,NM_001297427,NM_001297425,NM_001297428,NM_001297423,NM_032326 TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175,TMEM175 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4690326 4 953698 [A/C] NM_001347 DGKQ EXON Silent rs6599390 4 956047 [A/G] NM_001347 DGKQ Silent rs4690324 4 960081 [A/G] NM_001347 DGKQ Silent rs11248060 4 964359 [T/C] NM_001347 DGKQ Silent rs11724804 4 965779 [A/G] NM_001347 DGKQ Silent rs4583705 4 973036 [T/C] NM_134425 SLC26A1 EXON Silent rs17783233 4 976598 [T/C] NM_134425 SLC26A1 Silent rs11736451 4 977022 [A/G] NM_134425 SLC26A1 Silent rs3822030 4 987343 [T/G] NM_000203,NR_110313 IDUA,IDUA Silent,Silent rs11729777 4 989548 [T/C] NM_000203,NR_110313 IDUA,IDUA Silent,Silent rs4690222 4 992236 [A/G] NM_000203,NR_110313 IDUA,IDUA Silent,Silent rs3755955 4 994414 [A/G] NM_000203,NR_110313,NM_001363576 IDUA,IDUA,IDUA EXON Missense_R105Q,Silent,Silent rs6815946 4 995305 [T/C] NM_000203,NR_110313,NM_001363576 IDUA,IDUA,IDUA EXON Synonymous_N181N,Silent,Synonymous_N49N rs6855019 4 1001997 [T/C] rs6855233 4 1002125 [T/C] rs4505759 4 1003022 [T/C] rs34344380 4 1004359 [T/G] rs11734750 4 1006924 [T/C] NM_001004356,NM_001004358,NM_021923 FGFRL1,FGFRL1,FGFRL1 Silent,Silent,Silent rs34869253 4 1009420 [T/C] NM_001004356,NM_001004358,NM_021923 FGFRL1,FGFRL1,FGFRL1 Silent,Silent,Silent rs4647932 4 1019011 [T/C] NM_001004356,NM_001004358,NM_021923 FGFRL1,FGFRL1,FGFRL1 EXON Missense_P464L,Missense_P464L,Missense_P464L rs4647939 4 1019312 [A/G] NM_001004356,NM_001004358,NM_021923 FGFRL1,FGFRL1,FGFRL1 EXON Silent,Silent,Silent rs935973 4 1024287 [T/C] rs11722658 4 1024752 [T/C] rs10012074 4 1026866 [A/G] rs935971 4 1045265 [A/G] rs2045066 4 1052401 [T/C] rs12645644 4 1054159 [A/G] rs6817989 4 1054807 [A/C] rs4690213 4 1054868 [T/C] rs11732259 4 1064557 [A/G] rs17728127 4 1066769 [T/C] NM_194439,NM_001131034 RNF212,RNF212 EXON Silent,Missense_V263I rs1010342 4 1068819 [A/G] NM_194439,NM_001131034 RNF212,RNF212 Silent,Silent rs1466216 4 1071907 [A/G] NM_194439,NM_001131034 RNF212,RNF212 Silent,Silent rs11732520 4 1074009 [T/C] NM_194439,NM_001131034 RNF212,RNF212 Silent,Silent rs1670533 4 1078187 [A/G] NM_194439,NM_001131034 RNF212,RNF212 Silent,Silent rs17164229 4 1078596 [T/C] NM_194439,NM_001131034 RNF212,RNF212 Silent,Silent rs615381 4 1087531 [T/C] NM_194439,NM_001131034,NM_001193318 RNF212,RNF212,RNF212 EXON Silent,Silent,Missense_Q173R rs4045481 4 1090625 [A/G] NM_194439,NM_001131034,NM_001193318 RNF212,RNF212,RNF212 EXON Synonymous_T58T,Synonymous_T58T,Synonymous_T58T rs7686048 4 1094123 [T/C] NM_194439,NM_001131034,NM_001193318 RNF212,RNF212,RNF212 Silent,Silent,Silent rs3796619 4 1095281 [A/G] NM_194439,NM_001131034,NM_001193318 RNF212,RNF212,RNF212 Silent,Silent,Silent rs10033163 4 1095422 [A/G] NM_194439,NM_001131034,NM_001193318 RNF212,RNF212,RNF212 Silent,Silent,Silent rs6840347 4 1105680 [T/C] NM_194439,NM_001131034,NM_001193318 RNF212,RNF212,RNF212 Silent,Silent,Silent rs6836158 4 1111594 [A/G] NR_134676,NR_033768 LOC105374344,TMED11P Silent,Silent rs1904931 4 1113257 [A/G] NR_134676,NR_033768 LOC105374344,TMED11P Silent,Silent rs11735226 4 1121508 [T/C] NR_134676 LOC105374344 Silent rs6599284 4 1124038 [T/C] NR_134676 LOC105374344 Silent rs7659054 4 1124678 [T/C] NR_134676 LOC105374344 Silent rs7671502 4 1127010 [A/G] rs4974629 4 1135350 [A/G] rs10014526 4 1136910 [T/C] rs11937228 4 1147407 [A/G] rs10014245 4 1154202 [A/G] rs10013662 4 1157140 [T/C] rs10002437 4 1157776 [T/C] rs17802266 4 1158991 [A/C] rs7669287 4 1159680 [A/G] rs11247975 4 1165130 [T/G] NM_001199021,NM_001128325,NM_012445 SPON2,SPON2,SPON2 EXON Missense_A122E,Missense_A122E,Missense_A122E rs2242278 4 1165516 [A/G] NM_001199021,NM_001128325,NM_012445 SPON2,SPON2,SPON2 Silent,Silent,Silent rs922697 4 1165741 [A/G] NM_001199021,NM_001128325,NM_012445 SPON2,SPON2,SPON2 EXON Missense_L40P,Missense_L40P,Missense_L40P rs1272043 4 1190518 [A/G] NM_001199021,NR_024569 SPON2,LOC100130872 EXON Silent,Silent rs6599290 4 1192142 [T/C] NM_001199021,NR_024569 SPON2,LOC100130872 EXON Silent,Silent rs1250125 4 1192243 [A/G] NM_001199021,NR_024569 SPON2,LOC100130872 EXON Silent,Silent rs900030 4 1193832 [T/C] NM_001199021,NR_024569 SPON2,LOC100130872 EXON Silent,Silent rs1250105 4 1203265 [T/C] rs7666565 4 1203875 [A/G] rs1265923 4 1209174 [T/C] NR_104331,NM_001012614,NM_001328 CTBP1-AS,CTBP1,CTBP1 Silent,Silent,Silent rs1250092 4 1210654 [A/G] NR_104331,NM_001012614,NM_001328 CTBP1-AS,CTBP1,CTBP1 EXON Silent,Silent,Silent rs1250116 4 1224587 [T/C] NM_001012614,NM_001328 CTBP1,CTBP1 Silent,Silent rs1250114 4 1224648 [A/G] NM_001012614,NM_001328 CTBP1,CTBP1 Silent,Silent rs4974574 4 1224811 [A/G] NM_001012614,NM_001328 CTBP1,CTBP1 Silent,Silent rs884421 4 1227469 [T/C] NM_001012614,NM_001328 CTBP1,CTBP1 Silent,Silent rs3733340 4 1229688 [T/C] NM_001012614,NM_001328 CTBP1,CTBP1 Silent,Silent rs3755931 4 1236840 [T/C] NM_001012614,NM_001328 CTBP1,CTBP1 Silent,Silent rs3755930 4 1237014 [T/C] NM_001012614,NM_001328 CTBP1,CTBP1 Silent,Silent rs2335855 4 1237968 [T/C] NM_001012614,NM_001328 CTBP1,CTBP1 Silent,Silent rs730830 4 1240091 [T/C] NM_001012614,NM_001328 CTBP1,CTBP1 Silent,Silent rs1680032 4 1243573 [T/C] NR_033339 CTBP1-DT Silent rs3755920 4 1243617 [T/C] NR_033339 CTBP1-DT Silent rs2291199 4 1244267 [A/G] NR_033339 CTBP1-DT EXON Silent rs1732115 4 1244416 [A/G] NR_033339 CTBP1-DT EXON Silent rs1564508 4 1244879 [A/G] NR_033339 CTBP1-DT EXON Silent rs11247980 4 1274734 [A/G] rs1732103 4 1277826 [T/C] rs1680083 4 1278775 [A/G] rs11727167 4 1285521 [A/G] NM_001297430,NM_005882,NM_001017405,NR_123716,NM_001297431 MAEA,MAEA,MAEA,MAEA,MAEA Silent,Silent,Silent,Silent,Silent rs3817604 4 1291337 [T/C] NM_001297430,NM_005882,NM_001017405,NR_123716,NM_001297431 MAEA,MAEA,MAEA,MAEA,MAEA Silent,Silent,Silent,Silent,Silent rs17164620 4 1304161 [A/G] NM_001297430,NM_005882,NM_001017405,NR_123716,NM_001297431,NM_001297432,NM_001297433 MAEA,MAEA,MAEA,MAEA,MAEA,MAEA,MAEA Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7695691 4 1304632 [A/G] NM_001297430,NM_005882,NM_001017405,NR_123716,NM_001297431,NM_001297432,NM_001297433 MAEA,MAEA,MAEA,MAEA,MAEA,MAEA,MAEA Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6818213 4 1305962 [T/C] NM_001297430,NM_005882,NM_001017405,NR_123716,NM_001297431,NM_001297432,NM_001297433 MAEA,MAEA,MAEA,MAEA,MAEA,MAEA,MAEA Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10025665 4 1312267 [A/G] NM_001297430,NM_005882,NM_001017405,NR_123716,NM_001297431,NM_001297432,NM_001297433 MAEA,MAEA,MAEA,MAEA,MAEA,MAEA,MAEA Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11933855 4 1315183 [A/G] NM_001297430,NM_005882,NM_001017405,NR_123716,NM_001297431,NM_001297432,NM_001297433 MAEA,MAEA,MAEA,MAEA,MAEA,MAEA,MAEA Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1128427 4 1330759 [T/C] NM_001297430,NM_005882,NM_001017405,NR_123716,NM_001297431,NM_001297432,NM_001297433 MAEA,MAEA,MAEA,MAEA,MAEA,MAEA,MAEA EXON Synonymous_A224A,Synonymous_A251A,Synonymous_A292A,Silent,Missense_W226R,Synonymous_A291A,Synonymous_A244A rs13135102 4 1330983 [A/C] NM_001297430,NM_005882,NM_001017405,NR_123716,NM_001297431,NM_001297432,NM_001297433 MAEA,MAEA,MAEA,MAEA,MAEA,MAEA,MAEA Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13117476 4 1334721 [T/C] rs7671242 4 1339875 [A/G] rs13141992 4 1340765 [T/C] rs6847965 4 1347675 [T/C] NM_001317934,NM_020894,NM_001317935 UVSSA,UVSSA,UVSSA Silent,Silent,Silent rs12512607 4 1348248 [T/C] NM_001317934,NM_020894,NM_001317935 UVSSA,UVSSA,UVSSA Silent,Silent,Silent rs3806754 4 1350186 [A/G] NM_001317934,NM_020894,NM_001317935 UVSSA,UVSSA,UVSSA Silent,Silent,Silent rs4974609 4 1356924 [T/G] NM_001317934,NM_020894,NM_001317935 UVSSA,UVSSA,UVSSA Silent,Silent,Silent rs10024529 4 1363886 [A/G] NM_001317934,NM_020894,NM_001317935 UVSSA,UVSSA,UVSSA Silent,Silent,Silent rs6826415 4 1365623 [A/G] NM_001317934,NM_020894,NM_001317935 UVSSA,UVSSA,UVSSA Silent,Silent,Silent rs6832148 4 1365858 [T/C] NM_001317934,NM_020894,NM_001317935 UVSSA,UVSSA,UVSSA Silent,Silent,Silent rs4974559 4 1380848 [A/G] NM_001317934,NM_020894,NM_001317935 UVSSA,UVSSA,UVSSA EXON Silent,Silent,Silent rs13142985 4 1386570 [A/G] NM_175918 CRIPAK EXON Silent rs6599308 4 1387780 [A/G] NM_175918 CRIPAK EXON Silent rs4974620 4 1394016 [A/G] rs6814036 4 1415698 [T/C] rs4419429 4 1416863 [T/C] rs11721614 4 1500753 [T/C] rs7685554 4 1501899 [T/G] rs12647020 4 1507198 [A/G] rs11947258 4 1519322 [T/C] rs4075071 4 1523930 [A/G] rs7666926 4 1527766 [A/G] rs10029689 4 1533976 [T/C] rs4307023 4 1539392 [A/G] rs6822351 4 1541224 [T/G] rs6838024 4 1554748 [A/G] rs10050053 4 1563920 [T/C] rs4374681 4 1566164 [T/C] rs4865424 4 1568595 [T/G] rs4073272 4 1573364 [T/C] rs6813841 4 1578967 [A/G] rs6833307 4 1586036 [T/C] rs10023523 4 1588665 [A/G] rs4865438 4 1598331 [A/G] rs6858080 4 1610872 [T/C] rs3936194 4 1619530 [A/G] rs2166582 4 1631795 [T/C] rs11942233 4 1634506 [T/C] rs7667125 4 1635312 [A/G] rs6829285 4 1641578 [A/G] rs7676189 4 1646364 [T/C] NM_001297435,NM_001013622,NM_001174070 FAM53A,FAM53A,FAM53A Silent,Silent,Silent rs4865453 4 1647743 [T/C] NM_001297435,NM_001013622,NM_001174070 FAM53A,FAM53A,FAM53A Silent,Silent,Silent rs2044507 4 1648626 [T/C] NM_001297435,NM_001013622,NM_001174070 FAM53A,FAM53A,FAM53A Silent,Silent,Silent rs2895461 4 1659128 [T/C] NM_001297435,NM_001013622,NM_001174070 FAM53A,FAM53A,FAM53A Silent,Silent,Silent rs6852065 4 1684409 [T/C] NM_001297435,NM_001013622,NM_001174070 FAM53A,FAM53A,FAM53A Silent,Silent,Silent rs6599397 4 1684457 [A/G] NM_001297435,NM_001013622,NM_001174070 FAM53A,FAM53A,FAM53A Silent,Silent,Silent rs3958122 4 1693931 [T/C] rs2247341 4 1701317 [A/G] NM_001306075,NM_006527,NM_001306074 SLBP,SLBP,SLBP EXON Synonymous_Y112Y,Synonymous_Y151Y,Synonymous_Y116Y rs798756 4 1707447 [T/C] NM_001306075,NM_006527,NM_001306074 SLBP,SLBP,SLBP Silent,Silent,Silent rs11945830 4 1720258 [T/C] NM_001127266,NM_138385 TMEM129,TMEM129 EXON Missense_V101M,Missense_V101M rs798754 4 1720757 [A/G] NM_001127266,NM_138385 TMEM129,TMEM129 Silent,Silent rs2854915 4 1721654 [A/G] NM_001127266,NM_138385 TMEM129,TMEM129 Silent,Silent rs1374468 4 1724579 [T/C] NM_006342 TACC3 Silent rs2282763 4 1728120 [A/C] NM_006342 TACC3 Silent rs1063742 4 1729660 [T/C] NM_006342 TACC3 EXON Synonymous_S177S rs1063743 4 1729988 [A/G] NM_006342 TACC3 EXON Missense_G287S rs798758 4 1730254 [A/G] NM_006342 TACC3 EXON Synonymous_Q375Q rs798759 4 1730299 [A/G] NM_006342 TACC3 EXON Synonymous_A390A rs17680881 4 1732978 [A/G] NM_006342 TACC3 EXON Missense_G514E rs3752749 4 1737262 [T/C] NM_006342 TACC3 Silent rs4865463 4 1742400 [T/C] NM_006342 TACC3 Silent rs2403293 4 1744252 [A/G] NM_006342 TACC3 Silent rs4865468 4 1770357 [T/C] rs6599400 4 1785025 [A/C] rs1867926 4 1785738 [A/G] rs7668207 4 1786702 [A/G] rs12502543 4 1793925 [A/G] rs3135848 4 1797741 [T/C] NM_001354810,NM_001163213,NM_022965,NR_148971,NM_001354809,NM_000142 FGFR3,FGFR3,FGFR3,FGFR3,FGFR3,FGFR3 Silent,Silent,Silent,Silent,Silent,Silent rs743682 4 1797852 [A/G] NM_001354810,NM_001163213,NM_022965,NR_148971,NM_001354809,NM_000142 FGFR3,FGFR3,FGFR3,FGFR3,FGFR3,FGFR3 Silent,Silent,Silent,Silent,Silent,Silent rs2305185 4 1805478 [T/C] NM_001354810,NM_001163213,NM_022965,NR_148971,NM_001354809,NM_000142 FGFR3,FGFR3,FGFR3,FGFR3,FGFR3,FGFR3 EXON Synonymous_T330T,Silent,Silent,Silent,Synonymous_T330T,Synonymous_T330T VG04S25864 4 1806104 [T/G] NM_001354810,NM_001163213,NM_022965,NR_148971,NM_001354809,NM_000142 FGFR3,FGFR3,FGFR3,FGFR3,FGFR3,FGFR3 EXON Missense_G375C,Missense_G377C,Silent,Silent,Missense_G375C,Missense_G375C rs7688609 4 1807894 [A/G] NM_001354810,NM_001163213,NM_022965,NR_148971,NM_001354809,NM_000142 FGFR3,FGFR3,FGFR3,FGFR3,FGFR3,FGFR3 EXON Synonymous_T652T,Synonymous_T653T,Synonymous_T539T,Silent,Synonymous_T652T,Synonymous_T651T rs3135901 4 1809173 [T/C] NM_001354810,NM_001163213,NM_022965,NR_148971,NM_001354809,NM_000142 FGFR3,FGFR3,FGFR3,FGFR3,FGFR3,FGFR3 EXON Silent,Silent,Silent,Silent,Silent,Silent rs10026782 4 1814206 [A/C] NM_012318 LETM1 EXON Silent rs4865477 4 1815990 [A/G] NM_012318 LETM1 EXON Silent rs11943072 4 1821290 [A/G] NM_012318 LETM1 Silent rs28681468 4 1824020 [T/C] NM_012318 LETM1 EXON Missense_R499H rs2001193 4 1851952 [T/G] NM_012318 LETM1 Silent rs12503340 4 1864994 [A/G] rs4865483 4 1866358 [T/C] rs17132081 4 1908714 [T/G] NM_001042424,NM_007331,NM_133330,NM_133331,NM_133335,NM_133334 NSD2,NSD2,NSD2,NSD2,NSD2,NSD2 Silent,Silent,Silent,Silent,Silent,Silent rs10023086 4 1910823 [T/C] NM_001042424,NM_007331,NM_133330,NM_133331,NM_133335,NM_133334 NSD2,NSD2,NSD2,NSD2,NSD2,NSD2 Silent,Silent,Silent,Silent,Silent,Silent rs6814150 4 1917711 [T/G] NM_001042424,NM_007331,NM_133330,NM_133331,NM_133335,NM_133334 NSD2,NSD2,NSD2,NSD2,NSD2,NSD2 Silent,Silent,Silent,Silent,Silent,Silent rs10488835 4 1947324 [T/G] NM_001042424,NM_133330,NM_133331,NM_133335,NM_133334 NSD2,NSD2,NSD2,NSD2,NSD2 EXON Silent,Silent,Silent,Silent,Silent rs494893 4 1958171 [A/G] NM_001042424,NM_133330,NM_133331,NM_133335 NSD2,NSD2,NSD2,NSD2 Silent,Silent,Silent,Silent rs17132099 4 1962635 [T/C] NM_001042424,NM_133330,NM_133331,NM_133335 NSD2,NSD2,NSD2,NSD2 Silent,Silent,Silent,Silent rs17132105 4 1969881 [T/C] NM_001042424,NM_133330,NM_133331,NM_133335 NSD2,NSD2,NSD2,NSD2 Silent,Silent,Silent,Silent rs10034373 4 1982655 [T/C] NM_001042424,NM_133330,NM_133331,NM_133335 NSD2,NSD2,NSD2,NSD2 EXON Silent,Silent,Silent,Silent rs2187692 4 1983556 [A/G] NM_001042424,NM_133330,NM_133331,NM_133335 NSD2,NSD2,NSD2,NSD2 EXON Silent,Silent,Silent,Silent rs3135123 4 1986938 [A/G] NM_005663 NELFA Silent rs495367 4 1986972 [A/G] NM_005663 NELFA Silent rs1077020 4 1988193 [T/C] NM_005663,NR_030641 NELFA,MIR943 EXON Silent,Silent rs11725821 4 1990425 [A/G] NM_005663 NELFA Silent rs2234564 4 1991423 [A/G] NM_005663 NELFA Silent rs580602 4 1993985 [A/G] NM_005663 NELFA Silent rs550483 4 1994985 [A/G] NM_005663 NELFA Silent rs7375177 4 2054373 [T/C] rs382939 4 2058475 [T/C] rs11248082 4 2065946 [A/C] NM_178557 NAT8L EXON Silent rs414210 4 2068337 [A/C] NM_178557 NAT8L EXON Silent rs383370 4 2071655 [A/G] rs459943 4 2072244 [T/G] rs588341 4 2074526 [T/G] NM_181808 POLN Silent rs3117813 4 2078853 [T/C] NM_181808 POLN Silent rs3135157 4 2087202 [A/G] NM_181808 POLN Silent rs1923775 4 2103096 [T/C] NM_181808 POLN Silent rs3135056 4 2106836 [A/C] NM_181808 POLN Silent rs6824606 4 2137283 [T/C] NM_181808 POLN Silent rs554399 4 2139047 [A/G] NM_181808 POLN Silent rs482519 4 2140742 [A/G] NM_181808 POLN Silent rs1745335 4 2145720 [A/G] NM_181808 POLN Silent rs554222 4 2155017 [A/G] NM_181808 POLN Silent rs10488836 4 2160894 [T/C] NM_181808 POLN EXON Synonymous_L533L rs9328764 4 2176454 [A/G] NM_181808 POLN EXON Missense_R425C rs6830513 4 2181080 [T/C] NM_181808 POLN EXON Synonymous_T378T rs10011549 4 2194946 [T/C] NM_181808 POLN EXON Missense_G336S rs10018786 4 2195024 [T/G] NM_181808 POLN EXON Missense_M310L rs2353552 4 2210065 [A/C] NM_181808 POLN EXON Missense_Q121H rs6855461 4 2214418 [T/C] NM_181808 POLN Silent rs7677712 4 2221814 [T/C] NM_181808 POLN Silent rs6851446 4 2231600 [T/C] NM_181808 POLN Silent rs11937432 4 2233709 [A/G] NM_181808,NM_001303143,NM_024511 POLN,HAUS3,HAUS3 EXON Silent,Missense_I586T,Missense_I586T rs1179 4 2235690 [T/C] NM_181808,NM_001303143,NM_024511 POLN,HAUS3,HAUS3 Silent,Silent,Silent rs7660498 4 2244865 [A/G] rs762832 4 2249111 [A/G] rs880674 4 2250109 [T/C] NM_006454 MXD4 EXON Silent rs3811803 4 2250742 [T/C] NM_006454 MXD4 EXON Silent rs1052682 4 2252201 [T/C] NM_006454 MXD4 EXON Silent rs2236998 4 2256716 [A/G] NM_006454 MXD4 Silent rs2182683 4 2261720 [T/C] NM_006454 MXD4 Silent rs736455 4 2275145 [A/G] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs2051561 4 2275835 [A/G] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 EXON Synonymous_F720F,Synonymous_F690F,Synonymous_F650F rs4974666 4 2277497 [T/C] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs17132392 4 2277731 [T/G] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs17132396 4 2282523 [A/G] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs17132398 4 2283910 [T/C] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs11737692 4 2287421 [A/C] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs7681318 4 2294746 [T/C] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs13105288 4 2297550 [T/C] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs13120062 4 2297586 [A/G] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs12640733 4 2303099 [A/G] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs17768393 4 2303576 [T/C] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs2071664 4 2304007 [A/C] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs612428 4 2304946 [T/C] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs661301 4 2306053 [A/G] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 EXON Missense_S672P,Missense_S642P,Missense_S602P rs4974648 4 2307466 [T/C] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs743695 4 2307574 [A/C] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs4974674 4 2311361 [T/C] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs4479771 4 2316874 [A/G] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs654207 4 2324865 [T/C] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs2097298 4 2329295 [T/C] NM_020972,NM_001172656,NM_001172659 ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent rs34426652 4 2335396 [T/C] NM_020972,NM_001172656,NM_001172659,NM_001172660,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent,Silent,Silent rs2071684 4 2336825 [A/G] NM_020972,NM_001172656,NM_001172659,NM_001172660,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent,Silent,Silent rs3118617 4 2340417 [T/C] NM_020972,NM_001172656,NM_001172659,NM_001172660,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent,Silent,Silent rs7663204 4 2344374 [T/G] NM_020972,NM_001172656,NM_001172659,NM_001172660,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent,Silent,Silent rs6599427 4 2344692 [A/G] NM_020972,NM_001172656,NM_001172659,NM_001172660,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent,Silent,Silent rs1179042 4 2350919 [T/C] NM_020972,NM_001172656,NM_001172659,NM_001172660,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent,Silent,Silent rs11731588 4 2351350 [A/G] NM_020972,NM_001172656,NM_001172659,NM_001172660,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent,Silent,Silent rs3135127 4 2359802 [A/G] NM_020972,NM_001172656,NM_001172659,NM_001172660,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent,Silent,Silent rs3135143 4 2367744 [A/G] NM_020972,NM_001172656,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent rs1894433 4 2369253 [A/G] NM_020972,NM_001172656,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent rs10011996 4 2371083 [A/C] NM_020972,NM_001172656,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent rs4257708 4 2385384 [A/G] NM_020972,NM_001172656,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent rs13129389 4 2386411 [A/G] NM_020972,NM_001172656,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent rs3135093 4 2390303 [A/G] NM_020972,NM_001172656,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent rs7665960 4 2390684 [A/G] NM_020972,NM_001172656,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent rs9994096 4 2392839 [A/G] NM_020972,NM_001172656,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent rs2071674 4 2397084 [T/C] NM_020972,NM_001172656,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent rs9996449 4 2401347 [T/C] NM_020972,NM_001172656,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent rs875133 4 2403365 [A/G] NM_020972,NM_001172656,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent rs3135071 4 2406321 [A/G] NM_020972,NM_001172656,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent rs10009152 4 2408397 [T/C] NM_020972,NM_001172656,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent rs12499021 4 2408411 [A/G] NM_020972,NM_001172656,NM_001172658,NM_001172657 ZFYVE28,ZFYVE28,ZFYVE28,ZFYVE28 Silent,Silent,Silent,Silent rs2269493 4 2428463 [A/G] NM_001193282 CFAP99 Silent rs9993090 4 2430298 [T/C] NM_001193282 CFAP99 Silent rs1209520 4 2430887 [A/C] NM_001193282 CFAP99 Silent rs1203764 4 2437290 [A/G] NM_001193282 CFAP99 Silent rs17132548 4 2438704 [A/G] NM_001193282 CFAP99 EXON Missense_D72G rs3128843 4 2446532 [A/G] NM_001193282 CFAP99 Silent rs1203808 4 2452087 [T/C] NM_001193282 CFAP99 Silent rs846252 4 2465304 [A/G] rs704347 4 2470613 [A/G] rs13128459 4 2471236 [A/G] NM_002938,NM_001185010,NM_001185009 RNF4,RNF4,RNF4 EXON Silent,Silent,Silent rs704349 4 2471802 [A/G] NM_002938,NM_001185010,NM_001185009 RNF4,RNF4,RNF4 Silent,Silent,Silent rs4974695 4 2471974 [T/C] NM_002938,NM_001185010,NM_001185009 RNF4,RNF4,RNF4 Silent,Silent,Silent rs846238 4 2478521 [A/G] NM_002938,NM_001185010,NM_001185009 RNF4,RNF4,RNF4 Silent,Silent,Silent rs11248108 4 2481490 [A/G] NM_002938,NM_001185010,NM_001185009 RNF4,RNF4,RNF4 Silent,Silent,Silent rs17132647 4 2491695 [A/G] NM_002938,NM_001185010,NM_001185009 RNF4,RNF4,RNF4 Silent,Silent,Silent rs3749467 4 2499117 [T/G] NM_002938,NM_001185010,NM_001185009 RNF4,RNF4,RNF4 Silent,Silent,Silent rs1203863 4 2502637 [T/C] NM_002938,NM_001185010,NM_001185009 RNF4,RNF4,RNF4 Silent,Silent,Silent rs11935873 4 2503587 [T/C] NM_002938,NM_001185010,NM_001185009 RNF4,RNF4,RNF4 Silent,Silent,Silent rs1203861 4 2504910 [T/C] NM_002938,NM_001185010,NM_001185009 RNF4,RNF4,RNF4 Silent,Silent,Silent rs1203860 4 2505091 [T/G] NM_002938,NM_001185010,NM_001185009 RNF4,RNF4,RNF4 Silent,Silent,Silent rs1203847 4 2517447 [A/G] NM_002938,NM_001185010,NM_001185009 RNF4,RNF4,RNF4 EXON Silent,Silent,Silent rs1728273 4 2559990 [T/C] rs3864117 4 2626569 [A/G] rs17824073 4 2631009 [A/G] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs17824295 4 2636881 [A/G] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs2282766 4 2658327 [A/G] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs17825119 4 2674271 [T/G] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs7681728 4 2680515 [T/C] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs231704 4 2687521 [T/C] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs12509340 4 2688719 [A/G] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs1828803 4 2689449 [A/C] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs231707 4 2694385 [A/G] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs4690085 4 2697300 [A/G] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs16843217 4 2698230 [A/G] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A EXON Synonymous_V848V,Synonymous_V848V,Silent,Silent,Synonymous_V870V,Synonymous_V848V rs10010434 4 2701540 [A/G] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A EXON Missense_R923Q,Missense_R923Q,Silent,Silent,Missense_R945Q,Missense_R923Q rs12499320 4 2703081 [T/C] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs231697 4 2703101 [T/G] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs4690015 4 2707032 [A/G] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs11933659 4 2708022 [T/C] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs12502642 4 2714023 [T/C] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs16843264 4 2716704 [T/C] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs2295499 4 2717690 [T/C] NM_001256668,NM_003704,NR_046336,NR_046335,NM_001256667,NM_001256666 FAM193A,FAM193A,FAM193A,FAM193A,FAM193A,FAM193A Silent,Silent,Silent,Silent,Silent,Silent rs232722 4 2734626 [T/G] rs12511418 4 2734859 [A/C] rs16843316 4 2743983 [A/G] NM_001292016,NM_001161527,NM_024309 TNIP2,TNIP2,TNIP2 EXON Silent,Silent,Silent rs232712 4 2743999 [A/G] NM_001292016,NM_001161527,NM_024309 TNIP2,TNIP2,TNIP2 EXON Synonymous_A342A,Synonymous_A318A,Synonymous_A425A rs9683949 4 2744480 [T/C] NM_001292016,NM_001161527,NM_024309 TNIP2,TNIP2,TNIP2 Silent,Silent,Silent rs17831665 4 2744521 [T/C] NM_001292016,NM_001161527,NM_024309 TNIP2,TNIP2,TNIP2 Silent,Silent,Silent rs3733226 4 2744937 [A/G] NM_001292016,NM_001161527,NM_024309 TNIP2,TNIP2,TNIP2 Silent,Silent,Silent rs2341303 4 2747475 [A/G] NM_001292016,NM_001161527,NM_024309 TNIP2,TNIP2,TNIP2 Silent,Silent,Silent rs4690055 4 2748663 [A/G] NM_001292016,NM_001161527,NM_024309 TNIP2,TNIP2,TNIP2 Silent,Silent,Silent rs4690060 4 2760222 [A/G] rs1268385 4 2762679 [T/C] rs1263492 4 2764088 [A/G] rs6600766 4 2768630 [A/G] rs12504990 4 2770772 [T/C] rs7695151 4 2772530 [T/C] rs231331 4 2798170 [A/G] NM_001122681 SH3BP2 Silent rs1751848 4 2804476 [A/G] NM_001122681 SH3BP2 Silent rs3021121 4 2810972 [T/C] NM_001122681 SH3BP2 Silent rs422734 4 2815256 [T/G] NM_001122681,NM_001145855 SH3BP2,SH3BP2 Silent,Silent rs1263446 4 2816300 [A/G] NM_001122681,NM_001145855 SH3BP2,SH3BP2 Silent,Silent rs1626813 4 2819063 [A/G] NM_001122681,NM_001145855 SH3BP2,SH3BP2 Silent,Silent rs231402 4 2822467 [T/G] NM_001122681,NM_001145855,NM_001145856,NM_003023 SH3BP2,SH3BP2,SH3BP2,SH3BP2 EXON Synonymous_L41L,Synonymous_L69L,Synonymous_L98L,Synonymous_L41L rs3755882 4 2825660 [A/G] NM_001122681,NM_001145855,NM_001145856,NM_003023 SH3BP2,SH3BP2,SH3BP2,SH3BP2 Silent,Silent,Silent,Silent rs3213501 4 2826400 [T/C] NM_001122681,NM_001145855,NM_001145856,NM_003023 SH3BP2,SH3BP2,SH3BP2,SH3BP2 EXON Synonymous_H100H,Synonymous_H128H,Synonymous_H157H,Synonymous_H100H rs231399 4 2831383 [T/G] NM_001122681,NM_001145855,NM_001145856,NM_003023 SH3BP2,SH3BP2,SH3BP2,SH3BP2 EXON Synonymous_A250A,Synonymous_A278A,Synonymous_A307A,Synonymous_A250A rs189139 4 2832727 [T/C] NM_001122681,NM_001145855,NM_001145856,NM_003023 SH3BP2,SH3BP2,SH3BP2,SH3BP2 Silent,Silent,Silent,Silent rs231395 4 2834554 [T/C] NM_001122681,NM_001145855,NM_001145856,NM_003023 SH3BP2,SH3BP2,SH3BP2,SH3BP2 Silent,Silent,Silent,Silent rs231394 4 2836628 [T/C] NM_001122681,NM_001145855,NM_001145856,NM_003023 SH3BP2,SH3BP2,SH3BP2,SH3BP2 EXON Silent,Silent,Silent,Silent rs35780153 4 2845274 [T/C] rs12503220 4 2850142 [A/G] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1263360 4 2861430 [A/G] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10026792 4 2862190 [A/G] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17833172 4 2868514 [A/G] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16843511 4 2873337 [T/C] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs624833 4 2881256 [T/G] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1242228 4 2882007 [T/C] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3775068 4 2888441 [A/G] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16843169 4 2896425 [T/C] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 EXON Synonymous_C236C,Synonymous_C236C,Synonymous_C236C,Synonymous_C236C,Synonymous_C236C,Synonymous_C236C,Synonymous_C236C,Synonymous_C236C,Synonymous_C236C,Synonymous_C236C,Synonymous_C236C,Synonymous_C236C,Synonymous_C236C rs4690006 4 2901160 [A/C] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 EXON Missense_L387M,Missense_L387M,Missense_L387M,Missense_L387M,Missense_L387M,Missense_L387M,Missense_L387M,Missense_L387M,Missense_L387M,Missense_L387M,Missense_L387M,Missense_L387M,Missense_L387M rs2285084 4 2906285 [A/G] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6833874 4 2906382 [A/G] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4961 4 2906707 [T/G] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 EXON Missense_G460W,Missense_G460W,Missense_G460W,Missense_G460W,Missense_G460W,Missense_G460W,Missense_G460W,Missense_G460W,Missense_G460W,Missense_G460W,Missense_G460W,Missense_G460W,Missense_G460W rs4962 4 2910255 [T/A] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 EXON Missense_N510I,Missense_N510I,Missense_N510I,Missense_N510I,Missense_N510I,Missense_N510I,Missense_N541I,Missense_N541I,Missense_N541I,Missense_N541I,Missense_N510I,Missense_N510I,Missense_N510I rs17834108 4 2910702 [A/C] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16843589 4 2916931 [A/G] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4966 4 2930864 [T/C] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 EXON Silent,Silent,Synonymous_T954T,Silent,Synonymous_T954T,Synonymous_T985T,Silent,Synonymous_T1016T,Synonymous_T985T,Silent,Synonymous_T985T,Synonymous_T954T,Silent rs4968 4 2931190 [T/C] NM_001119,NM_001354754,NM_001354757,NM_001354756,NM_014190,NM_001354759,NM_014189,NM_001354762,NM_176801,NM_001354761,NM_001286645,NM_001354758,NM_001354755 ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1,ADD1 EXON Silent,Silent,Missense_S1063L,Silent,Missense_S1063L,Missense_S1094L,Silent,Missense_S1125L,Missense_S1094L,Silent,Missense_S1094L,Missense_S1063L,Silent rs3733220 4 2931910 [A/G] rs1034400 4 2932589 [T/C] NM_001146069,NM_001120,NM_001363679 MFSD10,MFSD10,MFSD10 EXON Synonymous_P448P,Synonymous_P448P,Silent rs1263349 4 2934308 [A/G] NM_001146069,NM_001120,NM_001363679 MFSD10,MFSD10,MFSD10 Silent,Silent,Silent rs1263338 4 2939018 [T/C] NR_015453 NOP14-AS1 EXON Silent rs2032463 4 2941988 [T/C] NR_015453,NM_003703,NM_001291978,NM_001291979 NOP14-AS1,NOP14,NOP14,NOP14 Silent,Silent,Silent,Silent rs1054090 4 2943361 [T/C] NR_015453,NM_003703,NM_001291978,NM_001291979 NOP14-AS1,NOP14,NOP14,NOP14 EXON Silent,Missense_Q716R,Missense_Q716R,Missense_Q716R rs2301376 4 2945516 [A/G] NR_015453,NM_003703,NM_001291978,NM_001291979 NOP14-AS1,NOP14,NOP14,NOP14 Silent,Silent,Silent,Silent rs7665452 4 2949878 [A/G] NR_015453,NM_003703,NM_001291978,NM_001291979 NOP14-AS1,NOP14,NOP14,NOP14 Silent,Silent,Silent,Silent rs2515960 4 2951804 [A/G] NR_015453,NM_003703,NM_001291978,NM_001291979 NOP14-AS1,NOP14,NOP14,NOP14 EXON Silent,Missense_L380S,Missense_L380S,Missense_L380S rs1063745 4 2952506 [A/G] NR_015453,NM_003703,NM_001291978,NM_001291979 NOP14-AS1,NOP14,NOP14,NOP14 EXON Silent,Silent,Silent,Silent rs2022485 4 2979601 [T/C] NM_001350173,NM_001004056,NM_005307,NM_182982,NM_001004057 GRK4,GRK4,GRK4,GRK4,GRK4 Silent,Silent,Silent,Silent,Silent rs3021136 4 2982459 [T/G] NM_001350173,NM_001004056,NM_005307,NM_182982,NM_001004057 GRK4,GRK4,GRK4,GRK4,GRK4 Silent,Silent,Silent,Silent,Silent rs2051555 4 2990375 [A/G] NM_001350173,NM_001004056,NM_005307,NM_182982,NM_001004057 GRK4,GRK4,GRK4,GRK4,GRK4 Silent,Silent,Silent,Silent,Silent rs2960306 4 2990499 [T/G] NM_001350173,NM_001004056,NM_005307,NM_182982,NM_001004057 GRK4,GRK4,GRK4,GRK4,GRK4 EXON Silent,Missense_R33L,Missense_R33L,Missense_R65L,Missense_R65L rs1024323 4 3006043 [T/C] NM_001350173,NM_001004056,NM_005307,NM_182982,NM_001004057 GRK4,GRK4,GRK4,GRK4,GRK4 EXON Silent,Missense_A110V,Missense_A110V,Missense_A142V,Missense_A142V rs2471325 4 3024044 [T/C] NM_001350173,NM_001004056,NM_005307,NM_182982,NM_001004057 GRK4,GRK4,GRK4,GRK4,GRK4 Silent,Silent,Silent,Silent,Silent rs1891710 4 3024723 [A/G] NM_001350173,NM_001004056,NM_005307,NM_182982,NM_001004057 GRK4,GRK4,GRK4,GRK4,GRK4 Silent,Silent,Silent,Silent,Silent rs2515933 4 3027897 [T/C] NM_001350173,NM_001004056,NM_005307,NM_182982,NM_001004057 GRK4,GRK4,GRK4,GRK4,GRK4 Silent,Silent,Silent,Silent,Silent rs2857844 4 3029588 [A/G] NM_001350173,NM_001004056,NM_005307,NM_182982,NM_001004057 GRK4,GRK4,GRK4,GRK4,GRK4 Silent,Silent,Silent,Silent,Silent rs7677445 4 3029623 [A/G] NM_001350173,NM_001004056,NM_005307,NM_182982,NM_001004057 GRK4,GRK4,GRK4,GRK4,GRK4 Silent,Silent,Silent,Silent,Silent rs3775065 4 3030097 [A/G] NM_001350173,NM_001004056,NM_005307,NM_182982,NM_001004057 GRK4,GRK4,GRK4,GRK4,GRK4 Silent,Silent,Silent,Silent,Silent rs2515930 4 3036004 [A/G] NM_001350173,NM_001004056,NM_005307,NM_182982,NM_001004057 GRK4,GRK4,GRK4,GRK4,GRK4 Silent,Silent,Silent,Silent,Silent rs1801058 4 3039150 [T/C] NM_001350173,NM_001004056,NM_005307,NM_182982,NM_001004057 GRK4,GRK4,GRK4,GRK4,GRK4 EXON Missense_V292A,Missense_V454A,Missense_V454A,Missense_V486A,Missense_V486A rs16843773 4 3042258 [T/C] NM_001350173,NM_001004056,NM_005307,NM_182982,NM_001004057 GRK4,GRK4,GRK4,GRK4,GRK4 Silent,Silent,Silent,Silent,Silent rs2471343 4 3042902 [A/C] rs2857847 4 3046853 [A/G] rs1313772 4 3058583 [A/G] rs7694687 4 3063817 [T/C] rs9993542 4 3068545 [T/C] NR_045414 HTT-AS Silent rs762855 4 3074795 [A/G] NR_045414 HTT-AS Silent rs7664480 4 3084269 [A/C] NM_002111 HTT Silent rs7693317 4 3107664 [A/G] NM_002111 HTT Silent rs10015979 4 3109442 [A/G] NM_002111 HTT Silent rs363084 4 3132436 [A/G] NM_002111 HTT Silent rs3025853 4 3133594 [A/G] NM_002111 HTT Silent rs6855981 4 3148276 [A/G] NM_002111 HTT Silent rs17781557 4 3148653 [T/G] NM_002111 HTT EXON Missense_I1091M rs11731237 4 3151813 [T/C] NM_002111 HTT Silent rs2530588 4 3156021 [A/C] NM_002111 HTT EXON Missense_A1167E rs363101 4 3156344 [T/C] NM_002111 HTT Silent rs6839274 4 3160630 [A/G] NM_002111 HTT Silent rs4690074 4 3162056 [T/C] NM_002111 HTT EXON Synonymous_L1267L rs363098 4 3174256 [T/C] NM_002111 HTT Silent rs3025837 4 3174845 [A/C] NM_002111 HTT EXON Missense_N1385H rs363097 4 3177259 [A/G] NM_002111 HTT Silent rs363096 4 3180021 [T/C] NM_002111 HTT Silent rs2298969 4 3186244 [A/G] NM_002111 HTT Silent rs10488840 4 3186993 [A/G] NM_002111 HTT Silent rs363125 4 3189547 [A/C] NM_002111 HTT EXON Missense_T1720N rs16844026 4 3190533 [T/C] NM_002111 HTT Silent rs363092 4 3196029 [A/C] NM_002111 HTT Silent rs363089 4 3203578 [A/G] NM_002111 HTT Silent rs362331 4 3215835 [T/C] NM_002111 HTT EXON Missense_Y2309H rs362321 4 3222028 [T/C] NM_002111 HTT EXON Synonymous_N2454N rs362273 4 3227419 [A/G] NM_002111 HTT EXON Synonymous_L2599L rs2276881 4 3231661 [A/G] NM_002111 HTT EXON Synonymous_L2719L rs362272 4 3234980 [A/G] NM_002111 HTT EXON Missense_V2786I rs362313 4 3235589 [T/C] NM_002111 HTT Silent rs362306 4 3242100 [A/G] NM_002111 HTT EXON Silent rs362303 4 3242307 [T/C] NM_002111 HTT EXON Silent rs362302 4 3242920 [T/C] NM_002111 HTT EXON Silent rs2530594 4 3250754 [A/G] NM_001330620 MSANTD1 Silent rs3129322 4 3252852 [T/C] NM_001330620,NM_001042690 MSANTD1,MSANTD1 Silent,Silent rs3095081 4 3263776 [T/C] rs2798224 4 3267668 [A/G] rs16844106 4 3270348 [T/C] rs2798221 4 3270488 [T/C] rs7658462 4 3283422 [T/C] rs12506821 4 3284560 [T/C] rs6446731 4 3284751 [A/G] rs3129317 4 3287655 [A/G] rs10022193 4 3291694 [A/G] rs2051559 4 3298800 [T/C] rs13129052 4 3300783 [A/G] rs994426 4 3303976 [A/G] rs2749786 4 3314966 [T/C] rs7657430 4 3316494 [A/C] NM_002926,NM_198229 RGS12,RGS12 EXON Silent,Silent rs2236052 4 3318413 [A/G] NM_002926,NM_198229 RGS12,RGS12 EXON Synonymous_S172S,Synonymous_S172S rs12643903 4 3321694 [A/G] NM_002926,NM_198229 RGS12,RGS12 Silent,Silent rs16844169 4 3324034 [T/C] NM_002926,NM_198229 RGS12,RGS12 Silent,Silent rs6826787 4 3326393 [A/G] NM_002926,NM_198229 RGS12,RGS12 Silent,Silent rs7668784 4 3339038 [T/G] NM_002926,NM_198229 RGS12,RGS12 Silent,Silent rs7688715 4 3342137 [A/G] NM_002926,NM_198229 RGS12,RGS12 Silent,Silent rs2749781 4 3346617 [T/C] NM_002926,NM_198229 RGS12,RGS12 Silent,Silent rs2749779 4 3350248 [A/G] NM_002926,NM_198229 RGS12,RGS12 Silent,Silent rs16844212 4 3369099 [T/C] NM_002926,NM_198229 RGS12,RGS12 Silent,Silent rs12640186 4 3374539 [T/C] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs6855619 4 3375722 [T/C] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs1005187 4 3384844 [A/G] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs11730455 4 3385540 [A/C] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs16844249 4 3387148 [T/C] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs16844251 4 3388009 [A/G] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs16844254 4 3389270 [A/G] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs12649466 4 3390900 [A/C] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs16844266 4 3393352 [A/G] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs12510769 4 3394374 [T/C] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs16844272 4 3395406 [T/G] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs11732375 4 3396963 [A/G] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs6852186 4 3405165 [T/C] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs1962767 4 3407694 [A/G] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs16844280 4 3409024 [T/C] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs1730768 4 3409359 [A/G] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs1406674 4 3409700 [T/C] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs10027926 4 3414654 [A/G] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs16844301 4 3415378 [A/G] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs762864 4 3419677 [A/G] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs12641989 4 3419840 [A/G] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs17804577 4 3424720 [A/G] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs2269497 4 3429856 [A/G] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 EXON Missense_N1124S,Missense_N1124S,Missense_N476S rs1203112 4 3430862 [T/C] NM_002926,NM_198229,NM_198227 RGS12,RGS12,RGS12 Silent,Silent,Silent rs6818397 4 3434885 [T/G] NM_198229,NM_198227 RGS12,RGS12 Silent,Silent rs13116176 4 3436588 [A/G] NM_198229,NM_198227 RGS12,RGS12 Silent,Silent rs16844364 4 3438643 [A/G] NM_198229,NM_198227 RGS12,RGS12 Silent,Silent rs743713 4 3443298 [A/G] rs2073505 4 3444503 [A/G] NM_001297439,NM_001528 HGFAC,HGFAC EXON Synonymous_A54A,Synonymous_A54A rs4690097 4 3445745 [T/C] NM_001297439,NM_001528 HGFAC,HGFAC Silent,Silent rs3748034 4 3446091 [T/G] NM_001297439,NM_001528 HGFAC,HGFAC EXON Missense_A218S,Missense_A218S rs4690098 4 3447156 [T/C] NM_001297439,NM_001528 HGFAC,HGFAC Silent,Silent rs16844383 4 3447243 [T/C] NM_001297439,NM_001528 HGFAC,HGFAC Silent,Silent rs16844401 4 3449652 [A/G] NM_001297439,NM_001528 HGFAC,HGFAC EXON Missense_R516H,Missense_R509H rs28468427 4 3449886 [A/G] NM_001297439,NM_001528 HGFAC,HGFAC EXON Synonymous_E563E,Synonymous_E556E rs2498323 4 3451109 [A/G] NM_001297439,NM_001528 HGFAC,HGFAC EXON Missense_R651Q,Missense_R644Q rs1203111 4 3454304 [A/G] rs4690099 4 3454454 [T/C] rs1203104 4 3463452 [A/G] rs10022329 4 3467519 [T/G] NM_001363811,NM_173660,NM_001301071,NM_001164673 DOK7,DOK7,DOK7,DOK7 Silent,Silent,Silent,Silent rs10937927 4 3469443 [A/G] NM_001363811,NM_173660,NM_001301071,NM_001164673 DOK7,DOK7,DOK7,DOK7 Silent,Silent,Silent,Silent rs10937928 4 3469458 [T/C] NM_001363811,NM_173660,NM_001301071,NM_001164673 DOK7,DOK7,DOK7,DOK7 Silent,Silent,Silent,Silent rs16844418 4 3471754 [T/C] NM_001363811,NM_173660,NM_001301071,NM_001164673 DOK7,DOK7,DOK7,DOK7 Silent,Silent,Silent,Silent rs6831256 4 3473139 [A/G] NM_001363811,NM_173660,NM_001301071,NM_001164673 DOK7,DOK7,DOK7,DOK7 Silent,Silent,Silent,Silent rs6842419 4 3477299 [A/G] NM_001363811,NM_173660,NM_001301071,NM_001164673 DOK7,DOK7,DOK7,DOK7 Silent,Silent,Silent,Silent rs2699426 4 3478323 [T/C] NM_001363811,NM_173660,NM_001301071,NM_001164673 DOK7,DOK7,DOK7,DOK7 Silent,Silent,Silent,Silent rs1881803 4 3485786 [A/G] NM_001363811,NM_173660,NM_001301071,NM_001164673 DOK7,DOK7,DOK7,DOK7 Silent,Silent,Silent,Silent rs13146709 4 3493215 [T/C] NM_001363811,NM_173660,NM_001301071,NM_001164673,NM_001256896 DOK7,DOK7,DOK7,DOK7,DOK7 Silent,Silent,Silent,Silent,Silent rs2699416 4 3494055 [T/C] NM_001363811,NM_173660,NM_001301071,NM_001164673,NM_001256896 DOK7,DOK7,DOK7,DOK7,DOK7 Silent,Silent,Silent,Silent,Silent rs6811423 4 3494600 [A/G] NM_001363811,NM_173660,NM_001301071,NM_001164673,NM_001256896 DOK7,DOK7,DOK7,DOK7,DOK7 EXON Missense_Q152R,Missense_Q296R,Missense_Q296R,Silent,Silent rs6811856 4 3494826 [A/C] NM_001363811,NM_173660,NM_001301071,NM_001164673,NM_001256896 DOK7,DOK7,DOK7,DOK7,DOK7 EXON Synonymous_S227S,Synonymous_S371S,Synonymous_S371S,Silent,Synonymous_S61S rs6850908 4 3494898 [T/C] NM_001363811,NM_173660,NM_001301071,NM_001164673,NM_001256896 DOK7,DOK7,DOK7,DOK7,DOK7 EXON Synonymous_Y251Y,Synonymous_Y395Y,Synonymous_Y395Y,Silent,Synonymous_Y85Y rs16844464 4 3494956 [T/C] NM_001363811,NM_173660,NM_001301071,NM_001164673,NM_001256896 DOK7,DOK7,DOK7,DOK7,DOK7 EXON Missense_P271S,Missense_P415S,Missense_P415S,Silent,Missense_P105S rs2699414 4 3495950 [T/C] NM_001363811,NM_173660,NM_001301071,NM_001164673,NM_001256896 DOK7,DOK7,DOK7,DOK7,DOK7 EXON Silent,Silent,Silent,Silent,Silent rs2252054 4 3496058 [T/C] NM_001363811,NM_173660,NM_001301071,NM_001164673,NM_001256896 DOK7,DOK7,DOK7,DOK7,DOK7 EXON Silent,Silent,Silent,Silent,Silent rs10937930 4 3496110 [T/C] NM_001363811,NM_173660,NM_001301071,NM_001164673,NM_001256896 DOK7,DOK7,DOK7,DOK7,DOK7 EXON Silent,Silent,Silent,Silent,Silent rs1054662 4 3496150 [A/G] NM_001363811,NM_173660,NM_001301071,NM_001164673,NM_001256896 DOK7,DOK7,DOK7,DOK7,DOK7 EXON Silent,Silent,Silent,Silent,Silent rs13136935 4 3496940 [T/C] NM_001363811,NM_001301071 DOK7,DOK7 Silent,Silent rs3468 4 3505448 [A/G] NM_002337,NR_110005 LRPAP1,LRPAP1 EXON Silent,Silent rs3184 4 3510514 [T/C] NM_002337,NR_110005 LRPAP1,LRPAP1 EXON Silent,Silent rs1049574 4 3514539 [A/G] NM_002337,NR_110005 LRPAP1,LRPAP1 EXON Silent,Silent rs6789 4 3514695 [A/G] NM_002337,NR_110005 LRPAP1,LRPAP1 EXON Silent,Silent rs1730775 4 3525057 [A/G] NM_002337,NR_110005 LRPAP1,LRPAP1 Silent,Silent rs762870 4 3528200 [T/C] NM_002337,NR_110005 LRPAP1,LRPAP1 Silent,Silent rs6821202 4 3541587 [A/C] rs7699191 4 3576446 [T/C] rs6817919 4 3582651 [T/C] NR_040045 LINC00955 Silent rs1188583 4 3585953 [T/C] NR_040045 LINC00955 Silent rs28585439 4 3592160 [T/C] NR_040045 LINC00955 EXON Silent rs6856283 4 3602109 [A/G] rs16844952 4 3606875 [T/G] rs1810606 4 3609390 [A/G] rs17628728 4 3632194 [T/C] rs7673350 4 3637536 [T/C] rs177802 4 3643599 [A/C] rs177798 4 3644957 [T/C] rs17202883 4 3650826 [T/C] rs177789 4 3651101 [T/C] rs4916611 4 3652592 [A/G] rs177780 4 3656013 [A/G] rs12644079 4 3656174 [A/C] rs2180259 4 3658324 [A/G] rs11731847 4 3659574 [T/C] rs17203086 4 3661134 [T/G] rs16844725 4 3663463 [T/C] rs177769 4 3664206 [A/G] rs1884412 4 3666471 [A/G] rs16844747 4 3668328 [T/C] rs177766 4 3669171 [A/G] rs724944 4 3674281 [A/G] rs10019539 4 3677583 [A/G] NR_034136 LINC02171 Silent rs9998020 4 3677888 [T/C] NR_034136 LINC02171 Silent rs6827536 4 3679491 [T/C] NR_034136 LINC02171 EXON Silent rs2880892 4 3683269 [A/G] rs4916622 4 3687360 [A/G] rs16844775 4 3688660 [A/G] rs10805007 4 3691191 [T/C] rs11930561 4 3692118 [A/C] rs4916608 4 3702481 [T/C] rs885797 4 3703725 [A/G] rs929006 4 3709475 [A/C] rs2748789 4 3710982 [A/G] rs6837039 4 3711721 [T/G] rs2857969 4 3712082 [A/G] rs2748784 4 3715551 [T/C] rs16844810 4 3718394 [T/C] rs11938629 4 3719380 [A/G] rs7377501 4 3721269 [A/C] rs7375509 4 3721299 [A/G] rs2748763 4 3722407 [A/G] rs2092898 4 3729652 [A/G] rs1894441 4 3734895 [T/C] rs2857962 4 3737883 [T/C] rs6851496 4 3738828 [T/C] rs2857960 4 3740612 [A/C] rs2857958 4 3741038 [T/G] rs445275 4 3742998 [T/G] rs4498196 4 3747842 [A/C] rs4916612 4 3750155 [A/C] rs10013535 4 3753417 [T/C] rs9291156 4 3754818 [A/G] rs9291157 4 3754853 [T/C] rs3935655 4 3760093 [A/G] rs7677352 4 3762004 [A/C] rs13118771 4 3765755 [T/C] rs9714431 4 3767394 [A/G] rs7681159 4 3775685 [T/C] rs13134185 4 3775957 [T/C] rs6822427 4 3780072 [T/C] rs7435195 4 3787202 [T/G] rs12501853 4 3791661 [A/G] rs7440077 4 3792442 [T/C] rs28622001 4 3793990 [A/G] rs28610504 4 3796387 [T/C] rs28605619 4 3804286 [T/C] rs28612860 4 3813929 [T/C] rs28590539 4 3824221 [T/C] rs28687658 4 3845104 [T/G] rs28414555 4 3854303 [A/G] rs28366830 4 3856471 [T/C] rs28650078 4 3866157 [T/C] rs28528880 4 3875234 [A/G] rs28689568 4 3912496 [T/C] rs11937045 4 3913930 [A/G] rs3889790 4 3923728 [A/G] rs28716006 4 3935145 [A/G] rs6422714 4 3942867 [T/C] rs7695071 4 3943984 [T/C] NR_130740,NR_130742,NR_130741 FAM86EP,FAM86EP,FAM86EP EXON Silent,Silent,Silent rs4974767 4 3980138 [A/C] rs11731258 4 4137172 [A/G] rs7679962 4 4167133 [T/C] rs6446473 4 4177173 [A/C] rs2920250 4 4183931 [T/C] rs6840829 4 4185610 [T/C] rs12506827 4 4193573 [A/C] NM_177998 OTOP1 Silent rs2916422 4 4206953 [A/G] NM_177998 OTOP1 Silent rs1991917 4 4207366 [T/G] NM_177998 OTOP1 Silent rs1991915 4 4208861 [T/C] NM_177998 OTOP1 Silent rs2916424 4 4209796 [A/G] NM_177998 OTOP1 Silent rs2920227 4 4219590 [A/G] NM_177998 OTOP1 Silent rs2920244 4 4238315 [T/G] NM_001297552,NM_032927,NM_001297551 TMEM128,TMEM128,TMEM128 Silent,Silent,Silent rs3846232 4 4247059 [T/C] NM_001297552,NM_032927,NM_001297551 TMEM128,TMEM128,TMEM128 Silent,Silent,Silent rs2916468 4 4249300 [T/C] NM_001297552,NM_032927,NM_001297551 TMEM128,TMEM128,TMEM128 Silent,Silent,Silent rs2916464 4 4249620 [T/C] NM_001297552,NM_032927,NM_001297551 TMEM128,TMEM128,TMEM128 EXON Silent,Silent,Silent rs2980098 4 4252956 [A/G] rs2916457 4 4253074 [T/C] rs2916456 4 4254798 [T/C] rs2980091 4 4258887 [T/C] rs11936688 4 4259052 [A/G] rs11943160 4 4259085 [T/G] rs10937817 4 4263087 [T/G] rs2920228 4 4263579 [A/C] rs6835291 4 4267129 [T/C] rs2920240 4 4267400 [T/G] rs1865328 4 4267929 [C/G] rs16835397 4 4268642 [T/C] rs7671899 4 4270726 [T/C] NM_001145725,NM_017816 LYAR,LYAR Silent,Silent rs10937831 4 4272502 [T/C] NM_001145725,NM_017816 LYAR,LYAR Silent,Silent rs2272740 4 4275287 [T/C] NM_001145725,NM_017816 LYAR,LYAR Silent,Silent rs2272739 4 4276475 [A/C] NM_001145725,NM_017816 LYAR,LYAR EXON Missense_D151Y,Missense_D151Y rs4689210 4 4277736 [T/C] NM_001145725,NM_017816 LYAR,LYAR Silent,Silent rs3733425 4 4279395 [A/G] NM_001145725,NM_017816 LYAR,LYAR Silent,Silent rs2980213 4 4285756 [T/G] NM_001145725,NM_017816 LYAR,LYAR Silent,Silent rs2980212 4 4285813 [A/G] NM_001145725,NM_017816 LYAR,LYAR Silent,Silent rs2980155 4 4291205 [T/C] NM_001145725,NM_017816 LYAR,LYAR Silent,Silent rs2980156 4 4291517 [T/C] NM_001145725,NM_017816 LYAR,LYAR Silent,Silent rs4689241 4 4296665 [A/G] NR_138481,NM_145291,NM_001330625 ZBTB49,ZBTB49,ZBTB49 Silent,Silent,Silent rs2980164 4 4297389 [A/G] NR_138481,NM_145291,NM_001330625 ZBTB49,ZBTB49,ZBTB49 Silent,Silent,Silent rs2920174 4 4298599 [A/G] NR_138481,NM_145291,NM_001330625 ZBTB49,ZBTB49,ZBTB49 Silent,Silent,Silent rs2920253 4 4300855 [T/C] NR_138481,NM_145291,NM_001330625 ZBTB49,ZBTB49,ZBTB49 Silent,Silent,Silent rs2920217 4 4304522 [A/C] NR_138481,NM_145291,NM_001330625 ZBTB49,ZBTB49,ZBTB49 EXON Silent,Missense_Y320S,Missense_Y320S rs4689254 4 4304605 [A/G] NR_138481,NM_145291,NM_001330625 ZBTB49,ZBTB49,ZBTB49 EXON Silent,Missense_A348T,Missense_A348T rs894486 4 4308513 [T/C] NR_138481,NM_145291,NM_001330625 ZBTB49,ZBTB49,ZBTB49 Silent,Silent,Silent rs16835572 4 4315947 [T/C] NR_138481,NM_145291,NM_001330625 ZBTB49,ZBTB49,ZBTB49 Silent,Silent,Silent rs2980181 4 4316736 [T/C] NR_138481,NM_145291,NM_001330625 ZBTB49,ZBTB49,ZBTB49 Silent,Silent,Silent rs6839561 4 4320468 [T/G] NR_138481,NM_145291,NM_001330625 ZBTB49,ZBTB49,ZBTB49 Silent,Silent,Silent rs894484 4 4323865 [A/G] rs1020265 4 4327912 [T/C] rs6855893 4 4333387 [T/C] rs1031095 4 4333418 [A/G] rs2980206 4 4335824 [T/C] rs2980207 4 4336008 [T/C] rs11735439 4 4337286 [A/G] rs6833372 4 4339626 [T/C] rs4688956 4 4343240 [T/C] rs4689307 4 4343261 [A/G] rs4689314 4 4346065 [T/C] rs10027109 4 4346237 [A/G] rs3981 4 4346427 [A/G] rs16835627 4 4346538 [T/C] rs4689316 4 4347505 [T/C] rs7668915 4 4349205 [A/G] rs6843595 4 4351730 [A/G] rs7677584 4 4354778 [T/C] rs7660124 4 4355274 [A/G] rs6446632 4 4355380 [T/C] rs7674400 4 4360381 [A/G] rs7698300 4 4360662 [A/G] rs10937869 4 4362223 [T/C] rs4279148 4 4362337 [A/G] rs10018486 4 4363642 [A/G] rs4689340 4 4365066 [T/C] rs4478124 4 4366380 [T/G] rs7690552 4 4366999 [T/G] rs11947790 4 4369240 [A/G] rs4330304 4 4369400 [A/G] rs12639864 4 4370684 [T/C] rs7664767 4 4371097 [A/G] rs12512085 4 4372439 [A/G] rs4494977 4 4376170 [A/C] rs6816148 4 4376744 [T/C] rs6825630 4 4381429 [T/G] rs4305464 4 4387560 [T/C] rs4689412 4 4388017 [A/G] NM_001287764,NM_001040101,NM_001287763 NSG1,NSG1,NSG1 EXON Silent,Silent,Silent rs4689416 4 4392357 [T/C] NM_001287764,NM_001040101,NM_001287763,NM_014392 NSG1,NSG1,NSG1,NSG1 Silent,Silent,Silent,Silent rs3792686 4 4393068 [T/C] NM_001287764,NM_001040101,NM_001287763,NM_014392 NSG1,NSG1,NSG1,NSG1 Silent,Silent,Silent,Silent rs10017186 4 4394618 [T/C] NM_001287764,NM_001040101,NM_001287763,NM_014392 NSG1,NSG1,NSG1,NSG1 Silent,Silent,Silent,Silent rs4555567 4 4397537 [A/G] NM_001287764,NM_001040101,NM_001287763,NM_014392 NSG1,NSG1,NSG1,NSG1 Silent,Silent,Silent,Silent rs4402980 4 4402199 [T/G] NM_001287764,NM_001040101,NM_001287763,NM_014392 NSG1,NSG1,NSG1,NSG1 Silent,Silent,Silent,Silent rs4234746 4 4404843 [A/G] NM_001287764,NM_001040101,NM_001287763,NM_014392 NSG1,NSG1,NSG1,NSG1 Silent,Silent,Silent,Silent rs9993572 4 4406716 [T/C] NM_001287764,NM_001040101,NM_001287763,NM_014392 NSG1,NSG1,NSG1,NSG1 Silent,Silent,Silent,Silent rs11726155 4 4410007 [T/C] NM_001287764,NM_001040101,NM_001287763,NM_014392 NSG1,NSG1,NSG1,NSG1 Silent,Silent,Silent,Silent rs10002237 4 4419611 [T/C] NM_001287764,NM_001040101,NM_001287763,NM_014392 NSG1,NSG1,NSG1,NSG1 EXON Silent,Silent,Silent,Silent rs7673866 4 4420337 [A/G] NM_001287764,NM_001040101,NM_001287763,NM_014392 NSG1,NSG1,NSG1,NSG1 EXON Silent,Silent,Silent,Silent rs4689519 4 4425620 [A/G] NM_001346300,NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent,Silent rs3935096 4 4427343 [T/C] NM_001346300,NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent,Silent rs11734030 4 4442734 [T/C] NM_001346300,NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent,Silent rs6446647 4 4445315 [A/G] NM_001346300,NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent,Silent rs7698589 4 4445875 [T/C] NM_001346300,NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent,Silent rs9990629 4 4474034 [T/C] NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent rs6446652 4 4487383 [A/G] NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent rs11937935 4 4487610 [T/C] NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent rs11940730 4 4490280 [T/C] NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent rs6811336 4 4491724 [T/C] NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent rs6838568 4 4498594 [T/C] NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent rs9654059 4 4520962 [A/G] NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent rs12644497 4 4526248 [A/G] NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent rs7684307 4 4533974 [T/C] NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent rs28695605 4 4534579 [A/C] NR_144414,NM_016930,NM_001346282,NM_001346281 STX18,STX18,STX18,STX18 Silent,Silent,Silent,Silent rs6829211 4 4550632 [A/C] NR_037888 STX18-AS1 Silent rs7689784 4 4555497 [T/C] NR_037888 STX18-AS1 Silent rs12646052 4 4557259 [T/G] NR_037888 STX18-AS1 Silent rs1345041 4 4559234 [T/C] NR_037888 STX18-AS1 Silent rs4689885 4 4560776 [T/C] NR_037888 STX18-AS1 Silent rs16835890 4 4562693 [A/G] NR_037888 STX18-AS1 Silent rs10016411 4 4562916 [T/C] NR_037888 STX18-AS1 Silent rs11728302 4 4565610 [A/G] NR_037888 STX18-AS1 Silent rs4689888 4 4569460 [T/C] NR_037888 STX18-AS1 Silent rs4689174 4 4579042 [A/G] NR_037888 STX18-AS1 Silent rs13142209 4 4585470 [T/C] NR_037888 STX18-AS1 Silent rs10428352 4 4586438 [T/C] NR_037888 STX18-AS1 Silent rs6446665 4 4593893 [A/C] NR_037888 STX18-AS1 Silent rs4234835 4 4594732 [T/C] NR_037888 STX18-AS1 Silent rs4689893 4 4594743 [A/G] NR_037888 STX18-AS1 Silent rs12509575 4 4602813 [T/C] NR_037888 STX18-AS1 Silent rs11733672 4 4602905 [T/C] NR_037888 STX18-AS1 Silent rs2033958 4 4610628 [A/C] NR_037888 STX18-AS1 Silent rs6853673 4 4614187 [T/G] NR_037888 STX18-AS1 Silent rs1837711 4 4615708 [A/G] NR_037888 STX18-AS1 Silent rs7686825 4 4625355 [A/G] NR_037888 STX18-AS1 Silent rs2582949 4 4627592 [T/G] NR_037888 STX18-AS1 Silent rs1510798 4 4629166 [T/G] NR_037888 STX18-AS1 Silent rs2102528 4 4631235 [T/C] NR_037888 STX18-AS1 Silent rs17706055 4 4638578 [T/G] NR_037888 STX18-AS1 Silent rs6840368 4 4645158 [A/C] NR_037888 STX18-AS1 Silent rs4689911 4 4651063 [T/C] NR_037888 STX18-AS1 Silent rs6830734 4 4653004 [T/C] NR_037888 STX18-AS1 Silent rs6824817 4 4653127 [A/G] NR_037888 STX18-AS1 Silent rs7694788 4 4673698 [T/C] NR_037888 STX18-AS1 Silent rs13140219 4 4675257 [T/C] NR_037888 STX18-AS1 Silent rs6446675 4 4675296 [A/G] NR_037888 STX18-AS1 Silent rs4552410 4 4678511 [T/C] NR_037888 STX18-AS1 Silent rs7675915 4 4678907 [A/G] NR_037888 STX18-AS1 Silent rs13149758 4 4682289 [A/G] NR_037888 STX18-AS1 Silent rs17707114 4 4686072 [A/G] NR_037888 STX18-AS1 Silent rs4458410 4 4687339 [A/G] NR_037888 STX18-AS1 Silent rs10937886 4 4689987 [T/C] NR_037888 STX18-AS1 Silent rs11732485 4 4696955 [A/C] NR_037888 STX18-AS1 Silent rs17713046 4 4697613 [A/G] NR_037888 STX18-AS1 Silent rs7690052 4 4700606 [T/C] NR_037888 STX18-AS1 Silent rs4476553 4 4704014 [T/C] NR_037888 STX18-AS1 Silent rs12503646 4 4711863 [T/C] NR_037888 STX18-AS1 EXON Silent rs767294 4 4713022 [T/C] rs12648481 4 4716184 [A/G] rs17713587 4 4716521 [A/C] rs1000579 4 4719494 [A/G] rs10004542 4 4720455 [A/G] rs1000578 4 4721078 [A/G] rs12644897 4 4721690 [A/G] rs10013273 4 4721965 [T/C] rs11724809 4 4723984 [A/G] rs13130037 4 4724676 [A/C] rs10009773 4 4727223 [A/G] rs10005569 4 4727507 [T/C] rs6814552 4 4728354 [T/G] rs4689928 4 4737134 [T/C] rs10029966 4 4737746 [T/G] rs4381992 4 4739301 [T/G] rs4689929 4 4739625 [T/G] rs13149006 4 4739687 [A/G] rs10516168 4 4744037 [A/C] rs6822612 4 4744593 [A/C] rs2172445 4 4745726 [A/G] rs4574345 4 4748816 [T/C] rs767564 4 4749898 [A/G] rs7679624 4 4751272 [T/G] rs16836215 4 4754129 [T/G] rs1318947 4 4761862 [A/G] rs6854227 4 4762672 [A/G] rs1039906 4 4764026 [T/C] NR_125892 LOC101928279 Silent rs6830371 4 4767695 [T/C] NR_125892 LOC101928279 Silent rs12186237 4 4774402 [A/G] NR_125892 LOC101928279 Silent rs1533095 4 4782575 [A/G] NR_125892 LOC101928279 Silent rs1533097 4 4784151 [T/G] NR_125892 LOC101928279 Silent rs2933568 4 4784580 [T/C] NR_125892 LOC101928279 Silent rs10937891 4 4792249 [T/C] rs7681595 4 4794814 [T/G] rs2933572 4 4799692 [A/G] rs2933573 4 4802946 [A/G] rs2087865 4 4803675 [A/G] rs13117653 4 4805454 [A/G] rs16836288 4 4807203 [A/C] rs4689941 4 4809353 [A/C] rs6832194 4 4809607 [A/G] rs10937893 4 4810491 [T/G] rs4689942 4 4810993 [T/C] rs17659785 4 4814852 [T/C] rs1907989 4 4818925 [A/G] rs17716572 4 4819835 [A/G] rs749286 4 4820679 [T/C] rs4689946 4 4820813 [T/C] rs10212960 4 4822309 [T/C] rs9291153 4 4827883 [A/G] rs7666443 4 4837058 [T/C] rs13121578 4 4845777 [A/G] rs12640329 4 4846142 [T/C] rs4597767 4 4848349 [A/G] NR_125765 LINC01396 Silent rs3733397 4 4849402 [A/G] NR_125765 LINC01396 Silent rs4435686 4 4851329 [A/G] NR_125765 LINC01396 Silent rs6819546 4 4851979 [T/C] NR_125765 LINC01396 Silent rs884690 4 4852354 [A/G] NR_125765 LINC01396 Silent rs4348044 4 4852867 [T/C] rs3821947 4 4860138 [A/G] rs3821949 4 4860402 [A/G] rs3775261 4 4863745 [A/C] NM_002448 MSX1 Silent rs1042484 4 4864381 [A/G] NM_002448 MSX1 Silent rs4464513 4 4867322 [T/G] rs4473606 4 4872247 [A/G] rs12501827 4 4880597 [T/C] rs7653986 4 4882944 [T/C] rs12500028 4 4883409 [A/C] rs12498543 4 4883459 [T/C] rs4280680 4 4889621 [A/C] rs16836361 4 4890733 [T/G] rs6817411 4 4891148 [T/C] rs4689185 4 4895024 [A/G] rs2968686 4 4895897 [T/C] rs13118392 4 4896233 [A/G] rs4566595 4 4905782 [A/C] rs4488884 4 4905825 [A/G] rs4689961 4 4908020 [A/G] rs11932240 4 4908281 [A/G] rs6446700 4 4911642 [A/G] rs4593079 4 4912942 [A/G] rs4639019 4 4917971 [A/C] rs736405 4 4923296 [T/C] NR_125893 LOC101928306 Silent rs13139027 4 4926166 [A/G] NR_125893 LOC101928306 Silent rs7678151 4 4932825 [A/G] NR_125893 LOC101928306 Silent rs10516169 4 4935309 [T/G] NR_125893 LOC101928306 Silent rs6446716 4 4937762 [A/G] NR_125893 LOC101928306 Silent rs11946368 4 4939423 [A/G] NR_125893 LOC101928306 Silent rs1010776 4 4942150 [T/C] NR_125893 LOC101928306 Silent rs11733243 4 4944451 [T/C] NR_125893 LOC101928306 Silent rs4558813 4 4944918 [T/C] NR_125893 LOC101928306 Silent rs4234841 4 4946111 [T/G] NR_125893 LOC101928306 Silent rs4330303 4 4949339 [A/G] NR_125893 LOC101928306 Silent rs2968680 4 4950210 [T/C] NR_125893 LOC101928306 Silent rs16836483 4 4950937 [A/G] NR_125893 LOC101928306 Silent rs4689190 4 4952982 [T/G] NR_125893 LOC101928306 Silent rs16836510 4 4953457 [A/G] NR_125893 LOC101928306 Silent rs4574343 4 4953904 [T/C] NR_125893 LOC101928306 Silent rs4689965 4 4965186 [A/G] NR_125893 LOC101928306 Silent rs2968687 4 4969808 [A/G] NR_125893 LOC101928306 Silent rs11734790 4 4970920 [A/G] NR_125893 LOC101928306 Silent rs10223021 4 4972091 [T/C] NR_125893 LOC101928306 Silent rs4689967 4 4984192 [A/G] NR_125893 LOC101928306 Silent rs4689968 4 4985810 [T/C] NR_125893 LOC101928306 Silent rs11726928 4 4988914 [A/G] NR_125893 LOC101928306 Silent rs10022680 4 4991380 [A/G] rs4522817 4 4995876 [A/G] rs13112154 4 5001578 [A/G] rs13124969 4 5005171 [A/C] rs4072934 4 5005218 [A/G] rs4392464 4 5005698 [A/G] rs7659395 4 5007377 [T/G] rs9999422 4 5010866 [T/G] rs6810546 4 5014223 [T/C] rs6446309 4 5015167 [T/C] rs10011142 4 5015486 [T/C] rs4689977 4 5022496 [A/G] rs10937615 4 5023112 [A/G] rs6820110 4 5033426 [T/C] rs11732574 4 5043674 [T/C] rs6836682 4 5047695 [T/C] rs10222952 4 5053674 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs9799796 4 5055774 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10009026 4 5057311 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs11727656 4 5059668 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs7692195 4 5060425 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1868047 4 5067789 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1982349 4 5071688 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs11940060 4 5073415 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6847646 4 5074816 [T/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10028432 4 5077162 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs17732017 4 5077822 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs13150536 4 5078646 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10937620 4 5078789 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs16836608 4 5080052 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1119781 4 5083090 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs976682 4 5085210 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6822181 4 5086219 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1447284 4 5087553 [T/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs7693293 4 5093523 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10428331 4 5096957 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs12507259 4 5112978 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs16836654 4 5115426 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs12509816 4 5116247 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6446322 4 5116291 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1900559 4 5119905 [A/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs12649783 4 5120597 [A/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6825132 4 5121450 [T/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs7660270 4 5125048 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs747224 4 5127546 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs12651470 4 5128511 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs11726208 4 5128641 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10011769 4 5135979 [T/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6856163 4 5136130 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs4689989 4 5137364 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1982348 4 5138296 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6853110 4 5138988 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs12511127 4 5142212 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10012571 4 5145806 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1562425 4 5146091 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1562427 4 5146683 [A/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs7672067 4 5154673 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1542203 4 5158436 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs7683724 4 5159654 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs998984 4 5160771 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs7667054 4 5161027 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs13128441 4 5162389 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs13121814 4 5162594 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1530609 4 5163447 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs3806723 4 5167734 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs3749566 4 5170284 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10022435 4 5170549 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs7654310 4 5182102 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs2369670 4 5182934 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs13115405 4 5185925 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs13123841 4 5187398 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs12650617 4 5187537 [A/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10937629 4 5188454 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs11936284 4 5189700 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs16836803 4 5192051 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs11730793 4 5192533 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs12506939 4 5195094 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1530612 4 5196226 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs12504675 4 5196546 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs989707 4 5210283 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs989708 4 5210567 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs17734102 4 5211645 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1031237 4 5213429 [T/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1562429 4 5216320 [A/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs11734549 4 5216885 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs11731545 4 5218136 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs16836902 4 5219619 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1812310 4 5221578 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs13123245 4 5228210 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs985222 4 5229884 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs11728257 4 5231140 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs7682020 4 5234491 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs4688922 4 5235815 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10000042 4 5237152 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs11729112 4 5237192 [A/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6817353 4 5241571 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10001177 4 5249944 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6446345 4 5257364 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs9985541 4 5265305 [A/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs7655639 4 5279796 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs7669364 4 5288159 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6849493 4 5309317 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6829618 4 5310171 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10031235 4 5324465 [A/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6853800 4 5324491 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10028484 4 5326726 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1393861 4 5327821 [A/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs878544 4 5332558 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs16837029 4 5333091 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B EXON Synonymous_E135E,Synonymous_E135E,Synonymous_E88E rs4689212 4 5341817 [T/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10028303 4 5347818 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs11727433 4 5365859 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6823666 4 5367365 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs16837061 4 5383127 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs11930775 4 5383242 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10937641 4 5384256 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs16837079 4 5387403 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs195140 4 5389231 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs9291090 4 5390637 [A/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs195134 4 5391783 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs11947561 4 5394250 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6840421 4 5394914 [T/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs11726374 4 5395071 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs739968 4 5395967 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs195129 4 5396855 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs16837117 4 5397383 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs16837119 4 5397431 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs2654498 4 5401326 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs2009157 4 5403545 [A/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10010358 4 5405805 [A/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs7679648 4 5412681 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs195113 4 5413525 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs3774847 4 5414102 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs195103 4 5417222 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs2301857 4 5418485 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs16837174 4 5419685 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs81607 4 5420729 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs195098 4 5424741 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs2654506 4 5426224 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs4017782 4 5427691 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs13141339 4 5427944 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs16837199 4 5434149 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs10488939 4 5434160 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs2369705 4 5436590 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs4689226 4 5437760 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs3774836 4 5438328 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs4689236 4 5439424 [A/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6847749 4 5439634 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6827240 4 5440224 [T/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs3733182 4 5448429 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B EXON Missense_R168G,Missense_R198G,Missense_R151G rs3733180 4 5450124 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs739965 4 5451856 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1001465 4 5452736 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs3774828 4 5454049 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs11732645 4 5454829 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6814599 4 5456794 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs3821925 4 5457295 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs6446363 4 5460027 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs16837305 4 5460088 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs3774820 4 5461058 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs1034748 4 5463014 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs3774817 4 5463535 [T/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs16837322 4 5466902 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs3815189 4 5468231 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs7661234 4 5469218 [T/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs2301855 4 5469810 [T/C] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs28607918 4 5476176 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs3774811 4 5480337 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs739970 4 5499335 [A/G] NM_001345969,NM_018401,NM_001306082 STK32B,STK32B,STK32B Silent,Silent,Silent rs16837350 4 5502783 [T/G] rs10000488 4 5503503 [T/C] rs16837352 4 5504274 [T/G] rs7683145 4 5505133 [T/C] rs7694195 4 5506755 [A/G] rs4600860 4 5508488 [A/G] rs10032518 4 5508665 [T/C] rs1468309 4 5516179 [A/G] rs10020769 4 5516502 [A/G] rs6446371 4 5526209 [A/G] rs886532 4 5527102 [A/C] NR_126519,NR_126517,NR_126518 LINC01587,LINC01587,LINC01587 EXON Silent,Silent,Silent rs2267654 4 5527249 [A/G] NR_126519,NR_126517,NR_126518 LINC01587,LINC01587,LINC01587 Silent,Silent,Silent rs1059159 4 5529234 [T/C] NR_126519,NR_126517,NR_126518 LINC01587,LINC01587,LINC01587 EXON Silent,Silent,Silent rs12641040 4 5532985 [A/G] rs16837389 4 5536310 [T/C] rs12505562 4 5541650 [T/C] rs3846230 4 5543143 [A/G] rs10937654 4 5550882 [A/C] rs13138291 4 5554134 [A/C] rs6814957 4 5554322 [A/G] rs11727214 4 5561358 [A/C] rs13113867 4 5563196 [A/G] rs12511039 4 5570221 [A/G] NM_147127,NM_001166136 EVC2,EVC2 EXON Synonymous_H1169H,Synonymous_H1089H rs4689258 4 5575751 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs7670299 4 5576140 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs4450870 4 5580774 [T/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs9995842 4 5587093 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs13109991 4 5591448 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs4334691 4 5592348 [T/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs4333126 4 5594969 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs7684204 4 5618307 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs4282111 4 5619221 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs4429676 4 5619332 [A/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs9993134 4 5621673 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs13131951 4 5622042 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs16837501 4 5624278 [T/C] NM_147127,NM_001166136 EVC2,EVC2 EXON Synonymous_E829E,Synonymous_E749E rs730469 4 5624670 [T/C] NM_147127,NM_001166136 EVC2,EVC2 EXON Missense_T699A,Missense_T619A rs6850875 4 5627471 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs1078758 4 5629298 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs7689275 4 5631673 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs880291 4 5636212 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs4353849 4 5638652 [T/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs10001971 4 5638799 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs6850210 4 5640595 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs747971 4 5641507 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs10025465 4 5641753 [T/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs751841 4 5642161 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs6833786 4 5643287 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs10024750 4 5647018 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs12108470 4 5654253 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs10804964 4 5656508 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs11735503 4 5658004 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs6842115 4 5658554 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs6829204 4 5658891 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs4688945 4 5660264 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs4689273 4 5665201 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs4298088 4 5667561 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs4524330 4 5667671 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs12645009 4 5668012 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs11730653 4 5668688 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs13146518 4 5677101 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs4689276 4 5682189 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs10937658 4 5682811 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs6837414 4 5683395 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs957727 4 5686924 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs957726 4 5686967 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs960055 4 5687281 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs7684327 4 5688643 [A/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs10937660 4 5688669 [T/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs4689278 4 5690902 [T/C] NM_147127,NM_001166136 EVC2,EVC2 EXON Missense_S230G,Missense_S150G rs10937661 4 5691199 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs10937662 4 5691320 [A/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs6852113 4 5694773 [T/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs13126806 4 5699097 [A/G] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs11725145 4 5703630 [A/C] NM_147127,NM_001166136 EVC2,EVC2 Silent,Silent rs7681283 4 5717867 [A/G] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs2291157 4 5721021 [A/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC EXON Missense_Q74P,Missense_Q74P,Missense_Q74P rs4513510 4 5721774 [A/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs1383178 4 5721930 [A/G] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs881686 4 5723145 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs16837598 4 5731074 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC EXON Missense_A114V,Missense_A114V,Missense_A114V rs899688 4 5731518 [A/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs1871587 4 5732978 [A/G] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs2291154 4 5735520 [T/G] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs13130333 4 5735715 [A/G] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs10440166 4 5742400 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs7674034 4 5743053 [A/G] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs6446393 4 5743509 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC EXON Synonymous_L257L,Synonymous_L257L,Synonymous_L257L rs6414624 4 5743512 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC EXON Missense_Y258H,Missense_Y258H,Missense_Y258H rs1480169 4 5743781 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs17689430 4 5745304 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs994812 4 5745392 [A/G] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs1871584 4 5745720 [A/G] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs1351357 4 5746620 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs2286343 4 5747072 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs4689312 4 5749784 [A/G] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs4688964 4 5749814 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs4688963 4 5749904 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC EXON Synonymous_N323N,Synonymous_N323N,Synonymous_N323N rs6813121 4 5751253 [A/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs3774861 4 5752654 [A/G] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs10011837 4 5752753 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs899694 4 5753053 [A/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs899693 4 5753111 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs899692 4 5753249 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs2035304 4 5753354 [A/G] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs3774867 4 5754115 [A/G] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs899691 4 5754544 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs2302075 4 5755542 [A/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC EXON Missense_T449K,Missense_T449K,Missense_T449K rs883994 4 5756967 [A/G] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs899690 4 5757469 [T/G] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs735172 4 5758869 [T/C] NM_001306090,NM_001306092,NM_153717 EVC,EVC,EVC Silent,Silent,Silent rs11939527 4 5761366 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs6855229 4 5762161 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs17747287 4 5770734 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs4689308 4 5771295 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs6446395 4 5773055 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs3856953 4 5774747 [A/C] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs7680147 4 5778783 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs4689304 4 5784934 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs1383180 4 5785442 [A/G] NM_001306090,NM_153717 EVC,EVC EXON Missense_R576Q,Missense_R576Q rs10007573 4 5788734 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs11737504 4 5790159 [T/C] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs7678015 4 5793156 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs17691258 4 5794481 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs6826372 4 5794904 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs2291152 4 5798627 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs2279252 4 5800494 [A/G] NM_001306090,NM_153717 EVC,EVC EXON Missense_R760Q,Missense_R760Q rs2306399 4 5803903 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs3774876 4 5804830 [T/C] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs1552057 4 5806366 [T/C] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs7654977 4 5809023 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs7680768 4 5809187 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs2279250 4 5812195 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs2279247 4 5812566 [A/G] NM_001306090,NM_153717 EVC,EVC Silent,Silent rs16837692 4 5812974 [A/C] NM_001306090,NM_153717 EVC,EVC EXON Silent,Silent rs3733186 4 5815381 [A/G] NM_001306090,NM_153717 EVC,EVC EXON Silent,Silent rs3733189 4 5815635 [T/C] NM_001306090,NM_153717 EVC,EVC EXON Silent,Silent rs3755847 4 5815929 [T/C] NM_001306090,NM_153717 EVC,EVC EXON Silent,Silent rs6813104 4 5816938 [T/C] rs17748291 4 5817866 [A/G] rs16837696 4 5819154 [T/C] rs11944616 4 5819381 [A/G] rs10937680 4 5819967 [T/C] rs10018612 4 5820158 [T/C] rs10937681 4 5820761 [A/C] rs3774879 4 5821622 [A/G] rs1057052 4 5822738 [A/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 EXON Silent,Silent,Silent,Silent rs3774883 4 5826597 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs2286286 4 5827079 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs6818391 4 5830414 [T/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs6820236 4 5831521 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs11723228 4 5833625 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs3755849 4 5836702 [T/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs3821937 4 5837325 [T/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs7654446 4 5838837 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs1383181 4 5840210 [A/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs2240492 4 5840887 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs13144677 4 5841649 [A/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs13125595 4 5841662 [T/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs3774885 4 5842856 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs2286280 4 5843328 [T/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs1979427 4 5847493 [A/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs3885409 4 5848928 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs11945849 4 5850343 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs2276877 4 5851343 [T/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs984576 4 5852138 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs6848864 4 5856509 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs10030434 4 5859510 [T/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs7356507 4 5860906 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs11935956 4 5863664 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs13146086 4 5865088 [T/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs7691078 4 5865361 [A/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs6838020 4 5866819 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs6446401 4 5866947 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs12508543 4 5871485 [T/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs6823027 4 5873648 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs9790594 4 5874579 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs4292278 4 5882084 [T/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs3774889 4 5882848 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs3774893 4 5887388 [A/C] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 Silent,Silent,Silent,Silent rs3755851 4 5889251 [A/G] NM_001288661,NM_001014809,NM_001288662,NM_001313 CRMP1,CRMP1,CRMP1,CRMP1 EXON Silent,Silent,Silent,Silent rs10004248 4 5895798 [T/G] rs6812766 4 5896702 [A/C] rs4456913 4 5901291 [T/C] rs10020979 4 5901873 [A/G] rs6446405 4 5902274 [A/G] rs4689296 4 5902723 [T/C] rs13146468 4 5910469 [T/C] rs6446407 4 5914110 [A/G] rs4689294 4 5919709 [A/G] rs16837803 4 5920389 [T/C] rs4425309 4 5924289 [A/C] rs11729343 4 5924458 [A/G] rs4443226 4 5924629 [A/G] rs12506399 4 5924794 [A/G] rs12505016 4 5926312 [T/C] rs7675169 4 5926551 [A/C] rs9999689 4 5927071 [T/C] rs9999966 4 5927355 [T/C] rs10016978 4 5928187 [T/C] rs4388028 4 5929976 [A/G] rs6840908 4 5931208 [T/C] rs6857538 4 5931713 [A/G] rs10937695 4 5932608 [A/C] rs6446410 4 5934814 [T/C] rs11727977 4 5935406 [T/C] rs17751160 4 5936570 [T/C] rs11945109 4 5936875 [T/G] rs4539987 4 5939053 [A/G] rs11725173 4 5939889 [T/G] rs16837872 4 5941155 [A/G] rs17694785 4 5943692 [T/C] rs7682973 4 5945106 [A/G] rs9684740 4 5948793 [A/G] rs10005242 4 5949558 [A/G] rs4431167 4 5954520 [A/G] rs7680750 4 5955591 [A/G] rs6855903 4 5956975 [T/C] rs16837906 4 5958489 [T/G] rs3733190 4 5960352 [A/G] NM_001364690,NM_001364689 C4orf50,C4orf50 EXON Silent,Silent rs16837914 4 5961380 [T/C] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs13107008 4 5961995 [A/C] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs6446414 4 5964345 [T/C] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs6839295 4 5966801 [T/C] NM_001364690,NM_001364689 C4orf50,C4orf50 EXON Missense_I1230V,Missense_I1409V rs878145 4 5967316 [A/G] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs13124429 4 5969640 [A/G] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs7674007 4 5970508 [T/C] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs6813176 4 5970798 [A/G] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs9996280 4 5971082 [T/C] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs16837957 4 5975174 [A/G] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs16837960 4 5975538 [A/G] NM_001364690,NM_001364689 C4orf50,C4orf50 EXON Missense_R1139W,Missense_R1318W rs4689290 4 5977553 [T/C] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs10433662 4 5980110 [T/C] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs11941221 4 5981004 [A/G] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs6821688 4 5982108 [T/C] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs6846882 4 5983053 [T/C] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs7672438 4 5983751 [A/G] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs4689288 4 5984952 [A/G] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs4688950 4 5985002 [A/G] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs10014397 4 5988237 [A/G] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs4689287 4 5990110 [A/C] NM_001364690,NM_001364689 C4orf50,C4orf50 EXON Missense_Q1042H,Missense_Q1221H rs747391 4 5992086 [T/C] NM_001364690,NM_001364689 C4orf50,C4orf50 EXON Missense_K384E,Missense_K563E rs4689286 4 5992556 [A/G] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs16838017 4 5995255 [T/G] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs6857506 4 5997514 [T/G] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs3887346 4 6000691 [T/C] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs7657266 4 6002830 [A/C] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs6838861 4 6018866 [A/C] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs4689318 4 6018891 [T/C] NM_001364690,NM_001364689 C4orf50,C4orf50 Silent,Silent rs878948 4 6024426 [T/C] rs2285986 4 6026058 [A/G] rs13119847 4 6026877 [A/C] rs4689322 4 6028838 [A/G] NM_001099433 JAKMIP1 Silent rs6821790 4 6029163 [A/G] NM_001099433 JAKMIP1 Silent rs13105242 4 6032178 [T/C] NM_001099433 JAKMIP1 Silent rs10026454 4 6032456 [A/G] NM_001099433 JAKMIP1 Silent rs6813726 4 6032801 [A/C] NM_001099433 JAKMIP1 Silent rs765831 4 6033657 [A/G] NM_001099433 JAKMIP1 Silent rs6819485 4 6034039 [A/G] NM_001099433 JAKMIP1 Silent rs7665309 4 6042732 [A/G] NM_001099433 JAKMIP1 Silent rs6446445 4 6046867 [A/G] NM_001099433 JAKMIP1 Silent rs6446446 4 6047757 [T/C] NM_001099433 JAKMIP1 Silent rs6815511 4 6049030 [A/G] NM_001099433 JAKMIP1 Silent rs9999178 4 6051735 [T/C] NM_001099433 JAKMIP1 Silent rs16838138 4 6058701 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs7438838 4 6058732 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs6814350 4 6059226 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs6821383 4 6062639 [T/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs17766228 4 6065298 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs16838164 4 6065430 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs17766335 4 6068267 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs11731133 4 6068495 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs3889723 4 6071895 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs6842183 4 6072923 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs3901458 4 6075470 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs6446452 4 6080817 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs4689333 4 6085431 [A/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs10516179 4 6086752 [T/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs4689336 4 6088956 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs17710575 4 6096087 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs12507895 4 6104378 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs13127967 4 6106033 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs7680061 4 6106821 [T/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs7673767 4 6109614 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs11731332 4 6113559 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs12186252 4 6115394 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs10212632 4 6116097 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs7694562 4 6116708 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs11732318 4 6122058 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs7664611 4 6122135 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs16838298 4 6126549 [T/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs4580721 4 6131812 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs4516797 4 6135717 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs4689343 4 6136653 [T/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs7687079 4 6138066 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs13115520 4 6139210 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs4512066 4 6140737 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs10017549 4 6143608 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs7691044 4 6147486 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs4398594 4 6151065 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs7680135 4 6154886 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs4522943 4 6156083 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs4389634 4 6161431 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs6824225 4 6166456 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs6446469 4 6168155 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs17773390 4 6173521 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs4688970 4 6175398 [T/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs17773514 4 6177056 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs4689355 4 6177135 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs10937705 4 6183184 [T/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs885420 4 6185816 [A/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs1877762 4 6191051 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs11943701 4 6194483 [A/G] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs10470721 4 6195962 [T/C] NM_001099433,NM_001306134,NM_001306133,NM_144720 JAKMIP1,JAKMIP1,JAKMIP1,JAKMIP1 Silent,Silent,Silent,Silent rs11728313 4 6196421 [T/C] NM_001099433,NM_144720 JAKMIP1,JAKMIP1 Silent,Silent rs4688973 4 6199980 [A/G] NM_001099433,NM_144720 JAKMIP1,JAKMIP1 Silent,Silent rs7377975 4 6200070 [A/G] NM_001099433,NM_144720 JAKMIP1,JAKMIP1 Silent,Silent rs16838428 4 6200768 [T/C] NM_001099433,NM_144720 JAKMIP1,JAKMIP1 Silent,Silent rs4274923 4 6213622 [A/G] NR_037863 LINC02495 Silent rs6858345 4 6218099 [T/G] NR_037863 LINC02495 Silent rs908017 4 6221614 [T/G] NR_037863 LINC02495 Silent rs4602567 4 6227628 [T/C] NR_037863 LINC02495 Silent rs908014 4 6232458 [T/C] NR_037863 LINC02495 Silent rs4688978 4 6233890 [A/G] NR_037863 LINC02495 Silent rs12510751 4 6235553 [A/G] NR_037863 LINC02495 EXON Silent rs7376535 4 6236514 [A/G] rs13103694 4 6237973 [A/G] rs6446477 4 6245217 [A/G] rs885030 4 6250182 [T/C] rs7680068 4 6256130 [A/G] rs9993703 4 6256489 [A/C] rs4361456 4 6256629 [A/G] rs4689381 4 6257188 [T/C] rs11934878 4 6259236 [A/C] rs3898050 4 6261776 [A/G] rs4688982 4 6267001 [T/C] rs13107806 4 6271071 [T/C] rs17718958 4 6275735 [A/G] NM_001145853,NM_006005 WFS1,WFS1 Silent,Silent rs10002743 4 6276581 [A/G] NM_001145853,NM_006005 WFS1,WFS1 Silent,Silent rs4689391 4 6280449 [A/G] NM_001145853,NM_006005 WFS1,WFS1 Silent,Silent rs752854 4 6281961 [T/C] NM_001145853,NM_006005 WFS1,WFS1 Silent,Silent rs10001190 4 6284633 [A/G] NM_001145853,NM_006005 WFS1,WFS1 Silent,Silent rs4458523 4 6289986 [T/G] NM_001145853,NM_006005 WFS1,WFS1 Silent,Silent rs10010131 4 6292915 [A/G] NM_001145853,NM_006005 WFS1,WFS1 Silent,Silent rs10012946 4 6293350 [T/C] NM_001145853,NM_006005 WFS1,WFS1 Silent,Silent rs4416547 4 6293967 [A/G] NM_001145853,NM_006005 WFS1,WFS1 Silent,Silent rs4481292 4 6298375 [T/C] NM_001145853,NM_006005 WFS1,WFS1 Silent,Silent rs3821943 4 6299940 [T/C] NM_001145853,NM_006005 WFS1,WFS1 Silent,Silent rs1801212 4 6302519 [A/G] NM_001145853,NM_006005 WFS1,WFS1 EXON Missense_V333I,Missense_V333I rs1801206 4 6302707 [T/C] NM_001145853,NM_006005 WFS1,WFS1 EXON Synonymous_V395V,Synonymous_V395V rs2230719 4 6303247 [T/C] NM_001145853,NM_006005 WFS1,WFS1 EXON Synonymous_A575A,Synonymous_A575A rs734312 4 6303354 [A/G] NM_001145853,NM_006005 WFS1,WFS1 EXON Missense_R611H,Missense_R611H rs1805070 4 6303680 [A/G] NM_001145853,NM_006005 WFS1,WFS1 EXON Missense_I720V,Missense_I720V rs1046314 4 6303955 [A/G] NM_001145853,NM_006005 WFS1,WFS1 EXON Synonymous_K811K,Synonymous_K811K rs3821945 4 6304118 [A/G] NM_001145853,NM_006005 WFS1,WFS1 EXON Missense_D866N,Missense_D866N rs1046317 4 6304242 [T/C] NM_001145853,NM_006005 WFS1,WFS1 EXON Silent,Silent rs1046322 4 6304448 [A/G] NM_001145853,NM_006005 WFS1,WFS1 EXON Silent,Silent rs7658531 4 6312175 [T/C] rs9986109 4 6312976 [A/G] rs10804976 4 6315954 [T/G] rs7697730 4 6324246 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C EXON Silent,Silent,Silent,Silent,Silent,Silent rs6446490 4 6324647 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C EXON Silent,Silent,Silent,Silent,Silent,Silent rs3796398 4 6324785 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C EXON Silent,Silent,Silent,Silent,Silent,Silent rs3796403 4 6325086 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C EXON Synonymous_I415I,Synonymous_I429I,Synonymous_I422I,Synonymous_I422I,Synonymous_I412I,Synonymous_I429I rs4689404 4 6333126 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs4689407 4 6341740 [T/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs4689408 4 6342213 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs7676409 4 6342359 [A/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs4689410 4 6344204 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs4689411 4 6344237 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs6856061 4 6348191 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs4386675 4 6351958 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs11730177 4 6356513 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs10937723 4 6357970 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs4689415 4 6361632 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs10446500 4 6362566 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs13122929 4 6363608 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs13124487 4 6364311 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs4689421 4 6366210 [T/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs6831971 4 6367467 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs4596320 4 6369731 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs4689422 4 6371350 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs16838654 4 6375122 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs16838658 4 6375269 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs4585379 4 6375986 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs6446495 4 6376273 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs4689424 4 6377309 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs4327561 4 6381323 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996,NM_181876 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent,Silent rs4688999 4 6383792 [A/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs11936718 4 6383965 [T/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs6851340 4 6384823 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs16838698 4 6386039 [A/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs755403 4 6389642 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs872858 4 6391045 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs4270639 4 6391735 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs2240268 4 6392342 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs2240264 4 6392879 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs7671165 4 6401102 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs7438559 4 6402732 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs7655407 4 6404531 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs6857081 4 6406411 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs7377185 4 6407801 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs6853134 4 6410449 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs7434469 4 6410746 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs10007735 4 6411979 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs13434456 4 6414398 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs11724328 4 6416437 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs7658616 4 6417028 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs16838780 4 6417785 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs4689440 4 6421406 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs878281 4 6422476 [A/C] NM_001363388,NM_020416,NM_001206995,NM_001206994,NM_001206996 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent,Silent rs11734695 4 6423060 [A/C] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs17778826 4 6425308 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs4345249 4 6427070 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs4469149 4 6427757 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs4689003 4 6428296 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs4689443 4 6429992 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs11942139 4 6431084 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs11724762 4 6433905 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs4689005 4 6435495 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs12510934 4 6435926 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs16838840 4 6439143 [A/C] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs17722973 4 6441415 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs6813956 4 6442931 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs12640531 4 6447500 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs9291117 4 6447607 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs17779675 4 6449514 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs16838853 4 6450950 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs10014123 4 6451080 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs12500979 4 6454012 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs10029948 4 6454335 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs6813305 4 6456871 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs4689447 4 6456998 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs4404624 4 6460539 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs872883 4 6464547 [T/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs7664714 4 6465791 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs7664961 4 6465928 [T/C] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs4689458 4 6467212 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs10937735 4 6471246 [A/G] NM_001363388,NM_020416,NM_001206995,NM_001206994 PPP2R2C,PPP2R2C,PPP2R2C,PPP2R2C Silent,Silent,Silent,Silent rs4234745 4 6479693 [T/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs11938118 4 6480469 [A/G] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs4331842 4 6481781 [T/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs13117055 4 6487726 [T/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs4689465 4 6490789 [T/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs7654321 4 6499037 [A/G] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs4689469 4 6507841 [A/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs10937739 4 6509412 [T/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs4623093 4 6515067 [T/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs4571410 4 6517005 [T/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs4565150 4 6517066 [T/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs3934547 4 6518046 [A/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs6820874 4 6518453 [A/G] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs4075006 4 6523276 [T/G] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs4075007 4 6523395 [A/G] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs7688267 4 6527362 [A/G] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs3934625 4 6532065 [T/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs4689472 4 6533061 [A/G] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs6850064 4 6540153 [A/G] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs4689477 4 6541749 [A/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs4610412 4 6542401 [T/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs10030485 4 6544606 [T/G] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs9654056 4 6546433 [A/G] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs11737849 4 6547317 [A/G] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs4358467 4 6550849 [A/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs10937742 4 6552170 [T/C] NM_001206995,NM_001206994 PPP2R2C,PPP2R2C Silent,Silent rs4380587 4 6558429 [T/C] NM_001206994 PPP2R2C Silent rs11731327 4 6560931 [A/G] NM_001206994 PPP2R2C Silent rs4689021 4 6570032 [T/C] rs11732212 4 6575960 [T/C] rs6847759 4 6593117 [T/C] NM_015274,NM_001292038 MAN2B2,MAN2B2 Silent,Silent rs12507418 4 6593437 [A/G] NM_015274,NM_001292038 MAN2B2,MAN2B2 Silent,Silent rs2301796 4 6594947 [A/C] NM_015274,NM_001292038 MAN2B2,MAN2B2 EXON Missense_Q243P,Missense_Q243P rs2301795 4 6596360 [A/G] NM_015274,NM_001292038 MAN2B2,MAN2B2 EXON Missense_V320M,Missense_V269M rs9994243 4 6599555 [A/G] NM_015274,NM_001292038 MAN2B2,MAN2B2 Silent,Silent rs2301790 4 6600012 [A/G] NM_015274,NM_001292038 MAN2B2,MAN2B2 EXON Missense_M446V,Missense_M395V rs6446513 4 6602941 [T/G] NM_015274,NM_001292038 MAN2B2,MAN2B2 Silent,Silent rs7659958 4 6607830 [T/C] NM_015274,NM_001292038 MAN2B2,MAN2B2 Silent,Silent rs6446514 4 6608856 [T/C] NM_015274,NM_001292038 MAN2B2,MAN2B2 Silent,Silent rs4689486 4 6610622 [T/C] NM_015274,NM_001292038 MAN2B2,MAN2B2 Silent,Silent rs11721430 4 6610668 [T/C] NM_015274,NM_001292038 MAN2B2,MAN2B2 Silent,Silent rs10049503 4 6616948 [T/C] NM_015274,NM_001292038 MAN2B2,MAN2B2 Silent,Silent rs16839023 4 6618090 [T/C] NM_015274,NM_001292038 MAN2B2,MAN2B2 Silent,Silent rs4689488 4 6619052 [A/G] NM_015274,NM_001292038 MAN2B2,MAN2B2 Silent,Silent rs4689490 4 6619204 [A/G] NM_015274,NM_001292038 MAN2B2,MAN2B2 EXON Synonymous_V933V,Synonymous_V882V rs7698546 4 6619378 [T/C] NM_015274,NM_001292038 MAN2B2,MAN2B2 Silent,Silent rs3733604 4 6620710 [A/G] NM_015274,NM_001292038 MAN2B2,MAN2B2 Silent,Silent rs3088248 4 6623332 [A/G] NM_015274,NM_001292038 MAN2B2,MAN2B2 EXON Silent,Silent rs9790604 4 6627084 [T/G] rs4689022 4 6628640 [T/C] rs16839049 4 6630195 [T/C] rs12645336 4 6633831 [T/C] rs6446517 4 6640962 [A/C] rs7660424 4 6644327 [A/G] NM_001272054,NM_001272053,NM_033296 MRFAP1,MRFAP1,MRFAP1 EXON Silent,Silent,Silent rs11736897 4 6645597 [T/C] rs4416546 4 6646220 [A/G] rs10804983 4 6647324 [T/G] rs4689024 4 6649619 [T/C] rs6810446 4 6650566 [A/C] rs4689498 4 6663319 [A/C] rs2285864 4 6670315 [T/C] rs724858 4 6671959 [T/C] rs4689506 4 6673462 [T/C] NR_134665,NR_134664 LINC02482,LINC02482 Silent,Silent rs4689510 4 6680577 [T/C] rs4689516 4 6687113 [A/G] rs11935439 4 6687545 [A/C] rs12500833 4 6688852 [T/C] rs10019716 4 6694163 [A/G] rs4645287 4 6694778 [A/C] rs3822262 4 6697766 [T/G] NM_005980 S100P Silent rs4493618 4 6701203 [T/C] rs13108143 4 6704980 [A/C] rs10025855 4 6708515 [T/C] rs4689523 4 6709345 [T/C] rs4689037 4 6709812 [A/C] NM_203462 MRFAP1L1 EXON Silent rs4368678 4 6712462 [A/C] rs6834838 4 6716849 [A/G] rs6834885 4 6716931 [A/G] rs3172604 4 6718775 [T/G] NM_018366 BLOC1S4 EXON Silent rs16839178 4 6732660 [A/G] rs4420981 4 6733493 [A/G] rs4393997 4 6733588 [A/G] rs4420983 4 6733659 [A/G] rs4689044 4 6734367 [A/G] rs7661864 4 6736365 [A/G] rs4689534 4 6736751 [T/G] rs4689536 4 6738883 [T/C] rs4543114 4 6746425 [A/G] rs4689542 4 6754570 [A/G] rs4302466 4 6755324 [A/G] rs10516190 4 6755936 [T/C] rs11935889 4 6757184 [T/C] rs2068344 4 6762107 [A/G] rs4689050 4 6763115 [T/C] rs7681358 4 6766870 [A/G] rs4689545 4 6767336 [T/C] rs4689547 4 6767551 [A/G] rs6446542 4 6768043 [A/G] rs6845618 4 6771474 [A/G] rs9995180 4 6776212 [A/G] rs6824277 4 6777024 [T/C] rs6854931 4 6777164 [T/C] rs4689552 4 6817928 [A/C] NM_001100590,NM_014743 KIAA0232,KIAA0232 Silent,Silent rs6833118 4 6833794 [T/C] NM_001100590,NM_014743 KIAA0232,KIAA0232 Silent,Silent rs6848312 4 6836662 [A/C] NM_001100590,NM_014743 KIAA0232,KIAA0232 Silent,Silent rs17728979 4 6852114 [A/G] NM_001100590,NM_014743 KIAA0232,KIAA0232 Silent,Silent rs16839370 4 6853637 [A/C] NM_001100590,NM_014743 KIAA0232,KIAA0232 Silent,Silent rs11723013 4 6854060 [T/C] NM_001100590,NM_014743 KIAA0232,KIAA0232 Silent,Silent rs6845985 4 6855767 [A/G] NM_001100590,NM_014743 KIAA0232,KIAA0232 Silent,Silent rs6836941 4 6857278 [T/C] NM_001100590,NM_014743 KIAA0232,KIAA0232 Silent,Silent rs10006395 4 6862131 [T/C] NM_001100590,NM_014743 KIAA0232,KIAA0232 Silent,Silent rs10022630 4 6868155 [T/C] NM_001100590,NM_014743 KIAA0232,KIAA0232 Silent,Silent rs10022837 4 6868452 [T/C] NM_001100590,NM_014743 KIAA0232,KIAA0232 Silent,Silent rs17796902 4 6868495 [A/C] NM_001100590,NM_014743 KIAA0232,KIAA0232 Silent,Silent rs13115900 4 6876569 [A/G] NM_001100590,NM_014743 KIAA0232,KIAA0232 Silent,Silent rs6828754 4 6877902 [T/C] NM_001100590,NM_014743 KIAA0232,KIAA0232 Silent,Silent rs3733606 4 6883012 [T/C] NM_001100590,NM_014743 KIAA0232,KIAA0232 EXON Silent,Silent rs3822268 4 6883514 [A/G] NM_001100590,NM_014743 KIAA0232,KIAA0232 EXON Silent,Silent rs6828784 4 6885815 [T/C] NM_001100590,NM_014743 KIAA0232,KIAA0232 EXON Silent,Silent rs7694173 4 6886650 [A/G] rs10001636 4 6886830 [A/G] rs9999836 4 6889967 [T/C] rs7675928 4 6890937 [T/C] rs3901368 4 6893681 [A/G] rs9985862 4 6896802 [A/G] rs6446548 4 6903159 [A/G] rs6826453 4 6904074 [A/G] rs10020189 4 6907052 [T/C] rs28396694 4 6907365 [T/C] rs4342189 4 6908390 [A/G] rs11735869 4 6910204 [A/C] rs4432749 4 6913707 [A/G] NM_001113361,NM_020773 TBC1D14,TBC1D14 Silent,Silent rs11934364 4 6915342 [A/G] NM_001113361,NM_020773 TBC1D14,TBC1D14 Silent,Silent rs7688690 4 6916263 [A/G] NM_001113361,NM_020773 TBC1D14,TBC1D14 Silent,Silent rs10937762 4 6918679 [A/G] NM_001113361,NM_020773 TBC1D14,TBC1D14 Silent,Silent rs10804990 4 6919661 [A/G] NM_001113361,NM_020773 TBC1D14,TBC1D14 Silent,Silent rs7668673 4 6919674 [T/C] NM_001113361,NM_020773 TBC1D14,TBC1D14 Silent,Silent rs6446552 4 6924241 [A/G] NM_001113361,NM_020773 TBC1D14,TBC1D14 Silent,Silent rs4323102 4 6930968 [T/C] NM_001113361,NM_020773 TBC1D14,TBC1D14 Silent,Silent rs9291123 4 6937984 [T/C] NM_001113361,NM_020773 TBC1D14,TBC1D14 Silent,Silent rs4234788 4 6941375 [T/C] NM_001113361,NM_020773 TBC1D14,TBC1D14 Silent,Silent rs11732898 4 6956134 [T/C] NM_001113361,NM_020773,NM_001330638 TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent rs4234791 4 6957297 [T/G] NM_001113361,NM_020773,NM_001330638 TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent rs41410847 4 6957332 [A/G] NM_001113361,NM_020773,NM_001330638 TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent rs4689568 4 6961589 [T/C] NM_001113361,NM_020773,NM_001330638 TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent rs9291126 4 6968942 [T/C] NM_001113361,NM_020773,NM_001330638 TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent rs6831368 4 6969919 [A/G] NM_001113361,NM_020773,NM_001330638 TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent rs6838042 4 6973049 [T/G] NM_001113361,NM_020773,NM_001330638 TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent rs10015163 4 6983677 [T/C] NM_001113361,NM_020773,NM_001330638 TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent rs1048009 4 6988677 [A/G] NM_001113361,NM_020773,NM_001330638 TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent rs3892490 4 6996129 [A/G] NM_001113361,NM_020773,NM_001330638,NM_001113363,NM_001286805 TBC1D14,TBC1D14,TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent,Silent,Silent rs17742611 4 7002344 [A/G] NM_001113361,NM_020773,NM_001330638,NM_001113363,NM_001286805 TBC1D14,TBC1D14,TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent,Silent,Silent rs2301819 4 7006541 [A/G] NM_001113361,NM_020773,NM_001330638,NM_001113363,NM_001286805 TBC1D14,TBC1D14,TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent,Silent,Silent rs6819148 4 7007461 [A/C] NM_001113361,NM_020773,NM_001330638,NM_001113363,NM_001286805 TBC1D14,TBC1D14,TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent,Silent,Silent rs10013211 4 7008078 [T/G] NM_001113361,NM_020773,NM_001330638,NM_001113363,NM_001286805 TBC1D14,TBC1D14,TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent,Silent,Silent rs11732301 4 7018195 [A/G] NM_001113361,NM_020773,NM_001330638,NM_001113363,NM_001286805 TBC1D14,TBC1D14,TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent,Silent,Silent rs12650264 4 7021365 [A/G] NM_001113361,NM_020773,NM_001330638,NM_001113363,NM_001286805 TBC1D14,TBC1D14,TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent,Silent,Silent rs6854776 4 7023479 [A/G] NM_001113361,NM_020773,NM_001330638,NM_001113363,NM_001286805 TBC1D14,TBC1D14,TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent,Silent,Silent rs10516182 4 7025909 [T/C] NM_001113361,NM_020773,NM_001330638,NM_001113363,NM_001286805 TBC1D14,TBC1D14,TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent,Silent,Silent rs6834102 4 7027041 [T/C] NM_001113361,NM_020773,NM_001330638,NM_001113363,NM_001286805 TBC1D14,TBC1D14,TBC1D14,TBC1D14,TBC1D14 Silent,Silent,Silent,Silent,Silent rs11546450 4 7032180 [A/G] NM_001113361,NM_020773,NM_001330638,NM_001113363,NM_001286805 TBC1D14,TBC1D14,TBC1D14,TBC1D14,TBC1D14 EXON Silent,Silent,Silent,Silent,Silent rs12119 4 7033671 [T/C] NM_001113361,NM_020773,NM_001330638,NM_001113363,NM_001286805,NR_033828 TBC1D14,TBC1D14,TBC1D14,TBC1D14,TBC1D14,LOC100129931 EXON Silent,Silent,Silent,Silent,Silent,Silent rs6852613 4 7035637 [A/G] NR_033828 LOC100129931 EXON Silent rs3857175 4 7039197 [A/G] NR_033828 LOC100129931 Silent rs10937779 4 7039326 [A/G] NR_033828 LOC100129931 Silent rs3857176 4 7039345 [A/C] NR_033828 LOC100129931 Silent rs10937780 4 7048842 [A/G] NM_152293 TADA2B Silent rs868489 4 7055253 [T/C] NM_152293 TADA2B Silent rs16835106 4 7059666 [A/C] NM_152293 TADA2B EXON Silent rs3796908 4 7061378 [A/G] NM_025196 GRPEL1 EXON Silent rs16839631 4 7061953 [T/C] NM_025196 GRPEL1 EXON Silent rs6836129 4 7063524 [T/G] NM_025196 GRPEL1 Silent rs3822270 4 7069804 [A/C] NM_025196 GRPEL1 EXON Silent rs4256224 4 7074583 [T/C] rs907526 4 7084835 [T/C] rs3857183 4 7084858 [A/G] rs3857184 4 7084985 [T/G] rs6446566 4 7086930 [T/G] rs11734660 4 7093834 [A/G] rs12642809 4 7097498 [A/G] rs4689599 4 7102597 [T/C] NR_027441 LINC02447 Silent rs4082843 4 7109083 [A/G] rs28401383 4 7109830 [A/G] rs4082846 4 7112676 [T/G] rs7378101 4 7113986 [A/G] rs11938388 4 7118527 [T/C] rs12647765 4 7120761 [T/C] rs10027697 4 7126063 [A/G] rs4689603 4 7128805 [T/C] rs16843076 4 7129001 [A/G] rs4689604 4 7129556 [A/G] rs2359009 4 7132365 [A/C] rs10155062 4 7133905 [A/G] rs17807577 4 7134206 [T/G] rs10804992 4 7135912 [T/C] rs4689608 4 7137119 [A/G] rs13127331 4 7137140 [T/C] rs4689066 4 7137202 [T/C] rs4689609 4 7137336 [T/C] rs16839667 4 7137521 [A/G] rs9762239 4 7137631 [T/C] rs7665697 4 7137993 [T/C] rs13149666 4 7140431 [T/C] rs7656556 4 7142427 [A/G] rs7687509 4 7142868 [A/G] rs3857190 4 7142970 [T/C] rs4689069 4 7145249 [A/G] rs4689071 4 7146033 [T/C] rs3901794 4 7149008 [T/G] rs6814125 4 7149407 [A/C] rs12233740 4 7151434 [T/C] rs10021205 4 7151708 [A/G] rs6836687 4 7151812 [A/G] rs6810509 4 7151930 [T/G] rs3915879 4 7154743 [T/C] rs12508556 4 7157382 [A/G] rs4689074 4 7163405 [T/C] rs12505331 4 7163426 [T/C] rs4689620 4 7165415 [A/G] rs4566655 4 7168998 [T/G] rs9991298 4 7170562 [T/C] rs3982 4 7172750 [A/C] rs4689623 4 7172827 [T/C] rs9999241 4 7174993 [A/G] rs4689078 4 7178278 [A/G] rs7692512 4 7183984 [A/G] rs6851506 4 7184370 [A/G] rs10017600 4 7186257 [A/G] rs4689626 4 7190015 [T/G] rs12642599 4 7191780 [T/G] rs4689630 4 7195054 [A/G] NM_020777 SORCS2 Silent rs6834325 4 7202789 [T/C] NM_020777 SORCS2 Silent rs4689081 4 7203659 [T/G] NM_020777 SORCS2 Silent rs2240200 4 7204174 [T/C] NM_020777 SORCS2 Silent rs3815181 4 7204493 [T/C] NM_020777 SORCS2 Silent rs951449 4 7206401 [T/C] NM_020777 SORCS2 Silent rs4461527 4 7207480 [T/C] NM_020777 SORCS2 Silent rs10937790 4 7208680 [T/C] NM_020777 SORCS2 Silent rs870860 4 7210808 [T/C] NM_020777 SORCS2 Silent rs4689637 4 7211197 [A/G] NM_020777 SORCS2 Silent rs12512052 4 7211739 [A/G] NM_020777 SORCS2 Silent rs11932810 4 7214696 [A/C] NM_020777 SORCS2 Silent rs13143421 4 7215211 [A/G] NM_020777 SORCS2 Silent rs4689642 4 7215322 [A/G] NM_020777 SORCS2 Silent rs12152570 4 7218072 [T/C] NM_020777 SORCS2 Silent rs4234797 4 7219907 [A/G] NM_020777 SORCS2 Silent rs16839840 4 7220548 [T/C] NM_020777 SORCS2 Silent rs12646898 4 7221071 [A/G] NM_020777 SORCS2 Silent rs12641883 4 7224235 [T/C] NM_020777 SORCS2 Silent rs4689090 4 7226751 [T/G] NM_020777 SORCS2 Silent rs4689093 4 7239621 [T/C] NM_020777 SORCS2 Silent rs11931042 4 7241780 [T/C] NM_020777 SORCS2 Silent rs2008121 4 7250020 [A/G] NM_020777 SORCS2 Silent rs2008103 4 7250232 [A/C] NM_020777 SORCS2 Silent rs905010 4 7253260 [T/C] NM_020777 SORCS2 Silent rs9291133 4 7256620 [T/C] NM_020777 SORCS2 Silent rs7686843 4 7257160 [T/C] NM_020777 SORCS2 Silent rs10025225 4 7258075 [T/C] NM_020777 SORCS2 Silent rs904989 4 7262170 [T/C] NM_020777 SORCS2 Silent rs867350 4 7265635 [A/G] NM_020777 SORCS2 Silent rs6845989 4 7265945 [A/C] NM_020777 SORCS2 Silent rs6826089 4 7266856 [T/G] NM_020777 SORCS2 Silent rs6446590 4 7271603 [T/G] NM_020777 SORCS2 Silent rs3913450 4 7274498 [T/C] NM_020777 SORCS2 Silent rs6831675 4 7279707 [T/C] NM_020777 SORCS2 Silent rs4689677 4 7280033 [A/G] NM_020777 SORCS2 Silent rs6814708 4 7280324 [T/C] NM_020777 SORCS2 Silent rs6857447 4 7282332 [A/G] NM_020777 SORCS2 Silent rs17755381 4 7282506 [A/G] NM_020777 SORCS2 Silent rs12647543 4 7283617 [A/G] NM_020777 SORCS2 Silent rs3857193 4 7288703 [A/C] NM_020777 SORCS2 Silent rs4689682 4 7289113 [T/C] NM_020777 SORCS2 Silent rs11946827 4 7291363 [A/C] NM_020777 SORCS2 Silent rs3846424 4 7292894 [T/C] NM_020777 SORCS2 Silent rs7656453 4 7295154 [A/G] NM_020777 SORCS2 Silent rs12498790 4 7297506 [T/C] NM_020777 SORCS2 Silent rs4689687 4 7304566 [A/G] NM_020777 SORCS2 Silent rs952588 4 7309924 [T/C] NM_020777 SORCS2 Silent rs3846427 4 7310976 [T/C] NM_020777 SORCS2 Silent rs3930439 4 7312054 [A/C] NM_020777 SORCS2 Silent rs11942816 4 7312145 [T/C] NM_020777 SORCS2 Silent rs3916118 4 7321511 [T/G] NM_020777 SORCS2 Silent rs1104939 4 7322423 [A/G] NM_020777 SORCS2 Silent rs4689705 4 7325002 [T/C] NM_020777 SORCS2 Silent rs4689707 4 7326199 [T/C] NM_020777 SORCS2 Silent rs11946683 4 7328221 [T/G] NM_020777 SORCS2 Silent rs3864203 4 7328416 [A/G] NM_020777 SORCS2 Silent rs6840423 4 7329324 [T/G] NM_020777 SORCS2 Silent rs3864202 4 7329426 [A/G] NM_020777 SORCS2 Silent rs6823860 4 7329446 [T/C] NM_020777 SORCS2 Silent rs3892224 4 7330107 [T/C] NM_020777 SORCS2 Silent rs16840053 4 7330676 [A/G] NM_020777 SORCS2 Silent rs7657904 4 7333152 [T/C] NM_020777 SORCS2 Silent rs3936616 4 7334424 [A/G] NM_020777 SORCS2 Silent rs4689710 4 7334778 [A/G] NM_020777 SORCS2 Silent rs7689486 4 7335580 [A/C] NM_020777 SORCS2 Silent rs16840065 4 7335948 [T/C] NM_020777 SORCS2 Silent rs3907647 4 7338619 [A/G] NM_020777 SORCS2 Silent rs7667847 4 7338852 [T/C] NM_020777 SORCS2 Silent rs10005640 4 7339378 [A/G] NM_020777 SORCS2 Silent rs16840080 4 7339720 [T/C] NM_020777 SORCS2 Silent rs10011842 4 7341243 [A/G] NM_020777 SORCS2 Silent rs13105398 4 7347203 [T/C] NM_020777 SORCS2 Silent rs2878616 4 7347217 [T/C] NM_020777 SORCS2 Silent rs11724125 4 7348593 [T/C] NM_020777 SORCS2 Silent rs11734491 4 7350677 [A/G] NM_020777 SORCS2 Silent rs7681365 4 7352477 [T/C] NM_020777 SORCS2 Silent rs13110208 4 7353052 [T/C] NM_020777 SORCS2 Silent rs3916114 4 7362054 [T/C] NM_020777 SORCS2 Silent rs17757615 4 7362647 [T/C] NM_020777 SORCS2 Silent rs10937807 4 7363007 [A/G] NM_020777 SORCS2 Silent rs17814167 4 7363952 [A/G] NM_020777 SORCS2 Silent rs12500910 4 7366947 [A/G] NM_020777 SORCS2 Silent rs36022449 4 7369230 [A/C] NM_020777 SORCS2 Silent rs13126941 4 7372806 [T/C] NM_020777 SORCS2 Silent rs2878610 4 7373836 [T/C] NM_020777 SORCS2 Silent rs3864206 4 7373948 [A/G] NM_020777 SORCS2 Silent rs3864210 4 7376694 [T/C] NM_020777 SORCS2 Silent rs3864218 4 7380808 [T/C] NM_020777 SORCS2 Silent rs3864220 4 7381431 [A/G] NM_020777 SORCS2 Silent rs3905843 4 7385168 [T/C] NM_020777 SORCS2 Silent rs4689719 4 7390415 [T/C] NM_020777 SORCS2 Silent rs4689721 4 7390448 [T/C] NM_020777 SORCS2 Silent rs13142618 4 7390715 [A/G] NM_020777 SORCS2 Silent rs12641352 4 7391471 [A/G] NM_020777 SORCS2 Silent rs6851949 4 7393898 [A/G] NM_020777 SORCS2 Silent rs7356467 4 7395823 [T/C] NM_020777 SORCS2 Silent rs9994834 4 7399054 [A/C] NM_020777 SORCS2 Silent rs9997426 4 7399225 [T/C] NM_020777 SORCS2 Silent rs16840236 4 7399604 [A/G] NM_020777 SORCS2 Silent rs6827958 4 7400117 [T/C] NM_020777 SORCS2 Silent rs4689726 4 7401208 [T/C] NM_020777 SORCS2 Silent rs6830500 4 7401468 [A/G] NM_020777 SORCS2 Silent rs4689728 4 7404127 [A/C] NM_020777 SORCS2 Silent rs6446597 4 7414226 [A/G] NM_020777 SORCS2 Silent rs4558873 4 7415038 [A/G] NM_020777 SORCS2 Silent rs4689116 4 7418773 [A/G] NM_020777 SORCS2 Silent rs6837589 4 7419276 [T/C] NM_020777 SORCS2 Silent rs4689739 4 7419553 [T/C] NM_020777 SORCS2 Silent rs10022359 4 7419924 [A/G] NM_020777 SORCS2 Silent rs13105690 4 7420184 [T/C] NM_020777 SORCS2 Silent rs7682286 4 7420575 [A/G] NM_020777 SORCS2 Silent rs4292336 4 7420785 [A/G] NM_020777 SORCS2 Silent rs7663695 4 7421007 [T/C] NM_020777 SORCS2 Silent rs7660356 4 7422453 [A/G] NM_020777 SORCS2 Silent rs11731502 4 7423842 [A/G] NM_020777 SORCS2 Silent rs7693497 4 7423851 [A/G] NM_020777 SORCS2 Silent rs9999662 4 7424945 [A/C] NM_020777 SORCS2 Silent rs12508214 4 7426937 [T/C] NM_020777 SORCS2 Silent rs4025904 4 7427899 [A/G] NM_020777 SORCS2 Silent rs10023533 4 7428355 [T/G] NM_020777 SORCS2 Silent rs4458454 4 7431266 [A/C] NM_020777 SORCS2 Silent rs6854437 4 7432402 [T/G] NM_020777,NM_001085382 SORCS2,PSAPL1 EXON Silent,Silent rs6849590 4 7432577 [A/G] NM_020777,NM_001085382 SORCS2,PSAPL1 EXON Silent,Silent rs10033032 4 7434017 [A/G] NM_020777,NM_001085382 SORCS2,PSAPL1 EXON Silent,Silent rs10014338 4 7434607 [A/C] NM_020777,NM_001085382 SORCS2,PSAPL1 EXON Silent,Silent rs6850206 4 7435721 [T/C] NM_020777,NM_001085382 SORCS2,PSAPL1 EXON Silent,Missense_V296M rs9997955 4 7437059 [A/G] NM_020777 SORCS2 Silent rs9998248 4 7437364 [A/G] NM_020777 SORCS2 Silent rs7660079 4 7438352 [T/C] NM_020777 SORCS2 Silent rs13435654 4 7439376 [A/C] NM_020777 SORCS2 Silent rs13117409 4 7440206 [A/G] NM_020777 SORCS2 Silent rs4234805 4 7441323 [T/C] NM_020777 SORCS2 Silent rs4689748 4 7442126 [A/G] NM_020777 SORCS2 Silent rs4356913 4 7445048 [A/C] NM_020777 SORCS2 Silent rs4443286 4 7448581 [T/C] NM_020777 SORCS2 Silent rs12502708 4 7451187 [T/C] NM_020777 SORCS2 Silent rs7694518 4 7459344 [A/G] NM_020777 SORCS2 Silent rs4639074 4 7460233 [A/G] NM_020777 SORCS2 Silent rs4380522 4 7460789 [T/C] NM_020777 SORCS2 Silent rs4599414 4 7463304 [A/G] NM_020777 SORCS2 Silent rs7654086 4 7465277 [T/C] NM_020777 SORCS2 Silent rs4411993 4 7466466 [T/C] NM_020777 SORCS2 Silent rs4613570 4 7466980 [A/G] NM_020777 SORCS2 Silent rs4689126 4 7467316 [T/C] NM_020777 SORCS2 Silent rs4495038 4 7473205 [T/C] NM_020777 SORCS2 Silent rs7683874 4 7475424 [A/G] NM_020777 SORCS2 Silent rs16840358 4 7478631 [T/C] NM_020777 SORCS2 Silent rs10937822 4 7480400 [T/C] NM_020777 SORCS2 Silent rs10937823 4 7480422 [T/C] NM_020777 SORCS2 Silent rs13353636 4 7481564 [A/C] NM_020777 SORCS2 Silent rs13353773 4 7481596 [A/G] NM_020777 SORCS2 Silent rs11930924 4 7483346 [T/C] NM_020777 SORCS2 Silent rs13115940 4 7484427 [T/C] NM_020777 SORCS2 Silent rs17828052 4 7485775 [T/C] NM_020777 SORCS2 Silent rs11737430 4 7489235 [A/G] NM_020777 SORCS2 Silent rs4234818 4 7489534 [A/G] NM_020777 SORCS2 Silent rs10937826 4 7489829 [T/G] NM_020777 SORCS2 Silent rs10804999 4 7489960 [T/C] NM_020777 SORCS2 Silent rs11730684 4 7490500 [A/C] NM_020777 SORCS2 Silent rs10032900 4 7491757 [A/G] NM_020777 SORCS2 Silent rs6820154 4 7492414 [T/G] NM_020777 SORCS2 Silent rs12506309 4 7495063 [T/C] NM_020777 SORCS2 Silent rs6857793 4 7495484 [A/G] NM_020777 SORCS2 Silent rs10937830 4 7495975 [T/C] NM_020777 SORCS2 Silent rs4689131 4 7496857 [A/G] NM_020777 SORCS2 Silent rs9647418 4 7498864 [A/G] NM_020777 SORCS2 Silent rs7692314 4 7501447 [A/G] NM_020777 SORCS2 Silent rs6446605 4 7508309 [T/C] NM_020777 SORCS2 Silent rs4689767 4 7508446 [A/G] NM_020777 SORCS2 Silent rs10000185 4 7509758 [T/C] NM_020777 SORCS2 Silent rs13128906 4 7513983 [A/G] NM_020777 SORCS2 Silent rs12650698 4 7515705 [T/C] NM_020777 SORCS2 Silent rs4487342 4 7517179 [A/G] NM_020777 SORCS2 Silent rs4639075 4 7519789 [A/G] NM_020777 SORCS2 Silent rs10025062 4 7521540 [A/G] NM_020777 SORCS2 Silent rs13117257 4 7521802 [T/C] NM_020777 SORCS2 Silent rs4689773 4 7522239 [T/C] NM_020777 SORCS2 Silent rs744356 4 7523273 [T/C] NM_020777 SORCS2 Silent rs744355 4 7523364 [T/C] NM_020777 SORCS2 Silent rs6840716 4 7525739 [A/C] NM_020777 SORCS2 Silent rs4429728 4 7529367 [T/C] NM_020777 SORCS2 Silent rs7694823 4 7533041 [A/C] NM_020777 SORCS2 Silent rs10007474 4 7533234 [T/C] NM_020777 SORCS2 Silent rs7695937 4 7533570 [A/G] NM_020777 SORCS2 Silent rs10021708 4 7533674 [A/G] NM_020777 SORCS2 Silent rs6812745 4 7534603 [A/G] NM_020777 SORCS2 Silent rs6446607 4 7535214 [T/C] NM_020777 SORCS2 Silent rs16840471 4 7535574 [A/G] NM_020777 SORCS2 Silent rs7696497 4 7536746 [T/C] NM_020777 SORCS2 Silent rs6855453 4 7537029 [T/C] NM_020777 SORCS2 Silent rs10028107 4 7544610 [T/C] NM_020777 SORCS2 Silent rs4689138 4 7546598 [A/G] NM_020777 SORCS2 Silent rs10470724 4 7547490 [A/G] NM_020777 SORCS2 Silent rs11721353 4 7547547 [T/C] NM_020777 SORCS2 Silent rs11937027 4 7549473 [A/G] NM_020777 SORCS2 Silent rs11942113 4 7549875 [A/G] NM_020777 SORCS2 Silent rs882266 4 7551651 [A/G] NM_020777 SORCS2 Silent rs4637403 4 7554721 [A/C] NM_020777 SORCS2 Silent rs16840505 4 7564758 [A/G] NM_020777 SORCS2 Silent rs4290892 4 7565734 [T/C] NM_020777 SORCS2 Silent rs7667548 4 7570358 [T/C] NM_020777 SORCS2 Silent rs11942379 4 7572718 [T/C] NM_020777 SORCS2 Silent rs4689781 4 7573488 [T/C] NM_020777 SORCS2 Silent rs6858110 4 7573950 [A/G] NM_020777 SORCS2 Silent rs13144333 4 7576024 [T/C] NM_020777 SORCS2 Silent rs7440772 4 7576612 [T/C] NM_020777 SORCS2 Silent rs4459991 4 7582052 [A/G] NM_020777 SORCS2 Silent rs4689786 4 7584560 [T/C] NM_020777 SORCS2 Silent rs10012347 4 7584767 [T/C] NM_020777 SORCS2 Silent rs6835799 4 7586924 [A/G] NM_020777 SORCS2 Silent rs4689789 4 7588936 [T/C] NM_020777 SORCS2 Silent rs11735301 4 7590048 [T/C] NM_020777 SORCS2 Silent rs4594727 4 7592068 [T/G] NM_020777 SORCS2 Silent rs734526 4 7597452 [T/G] NM_020777 SORCS2 Silent rs11933482 4 7597712 [A/G] NM_020777 SORCS2 Silent rs7667970 4 7600936 [A/G] NM_020777 SORCS2 Silent rs757240 4 7607757 [A/G] NM_020777 SORCS2 Silent rs12503735 4 7607924 [T/C] NM_020777 SORCS2 Silent rs16840640 4 7612515 [T/C] NM_020777 SORCS2 Silent rs10021084 4 7612772 [T/C] NM_020777 SORCS2 Silent rs16840670 4 7615377 [A/G] NM_020777 SORCS2 Silent rs13145735 4 7619653 [A/G] NM_020777 SORCS2 Silent rs10937843 4 7620682 [A/G] NM_020777 SORCS2 Silent rs4689801 4 7624478 [A/G] NM_020777 SORCS2 Silent rs10937844 4 7625979 [T/C] NM_020777 SORCS2 Silent rs4689806 4 7626136 [T/C] NM_020777 SORCS2 Silent rs2884800 4 7628406 [T/G] NM_020777 SORCS2 Silent rs886372 4 7629251 [A/G] NM_020777 SORCS2 Silent rs757239 4 7629288 [T/C] NM_020777 SORCS2 Silent rs4689808 4 7632223 [A/G] NM_020777 SORCS2 Silent rs4689148 4 7637297 [T/C] NM_020777 SORCS2 Silent rs2158276 4 7639906 [A/C] NM_020777 SORCS2 Silent rs2158275 4 7645289 [A/G] NM_020777 SORCS2 Silent rs11932646 4 7646256 [A/C] NM_020777 SORCS2 Silent rs886366 4 7654022 [A/G] NM_020777 SORCS2 Silent rs2285789 4 7655855 [T/C] NM_020777 SORCS2 Silent rs11737898 4 7660146 [A/G] NM_020777 SORCS2 Silent rs1158073 4 7661649 [A/G] NM_020777 SORCS2 Silent rs6810814 4 7665945 [A/G] NM_020777 SORCS2 Silent rs2214459 4 7667486 [T/C] NM_020777 SORCS2 Silent rs10488964 4 7669798 [T/C] NM_020777 SORCS2 Silent rs6816649 4 7672424 [A/G] NM_020777 SORCS2 Silent rs11724048 4 7672785 [T/G] NM_020777 SORCS2 Silent rs10013239 4 7680962 [A/C] NM_020777 SORCS2 Silent rs7697323 4 7683417 [A/G] NM_020777 SORCS2 Silent rs4689820 4 7684641 [A/C] NM_020777 SORCS2 Silent rs2079169 4 7685529 [A/G] NM_020777 SORCS2 Silent rs2359633 4 7685758 [T/C] NM_020777 SORCS2 Silent rs2884743 4 7685801 [T/C] NM_020777 SORCS2 Silent rs16840826 4 7687588 [A/G] NM_020777 SORCS2 Silent rs1006467 4 7687652 [T/G] NM_020777 SORCS2 Silent rs886378 4 7689152 [A/C] NM_020777 SORCS2 Silent rs886376 4 7690403 [A/G] NM_020777 SORCS2 Silent rs17381732 4 7690857 [A/C] NM_020777 SORCS2 Silent rs4689825 4 7693469 [A/C] NM_020777 SORCS2 Silent rs10023670 4 7694472 [T/C] NM_020777 SORCS2 Silent rs2057723 4 7698316 [A/G] NM_020777 SORCS2 Silent rs6845903 4 7700712 [T/C] NM_020777 SORCS2 Silent rs2359630 4 7704795 [T/C] NM_020777 SORCS2 Silent rs4689830 4 7708889 [A/C] NM_020777 SORCS2 Silent rs12500759 4 7709880 [T/C] NM_020777 SORCS2 Silent rs766008 4 7710640 [A/C] NM_020777 SORCS2 Silent rs2359610 4 7712266 [T/C] NM_020777 SORCS2 Silent rs4689832 4 7714212 [A/G] NM_020777 SORCS2 Silent rs4689833 4 7714490 [T/C] NM_020777 SORCS2 EXON Synonymous_D633D rs11726260 4 7715181 [A/G] NM_020777 SORCS2 Silent rs16840892 4 7716061 [T/C] NM_020777 SORCS2 EXON Missense_T695M rs6816604 4 7716932 [T/C] NM_020777 SORCS2 EXON Missense_S716P rs2285781 4 7717012 [A/G] NM_020777 SORCS2 EXON Synonymous_L742L rs16840899 4 7717020 [T/C] NM_020777 SORCS2 EXON Missense_T745I rs16840900 4 7717629 [T/C] NM_020777 SORCS2 Silent rs4689835 4 7718534 [T/G] NM_020777 SORCS2 Silent rs4689836 4 7718802 [T/C] NM_020777 SORCS2 Silent rs2285780 4 7720077 [T/C] NM_020777 SORCS2 Silent rs4689838 4 7720834 [T/C] NM_020777 SORCS2 Silent rs2097769 4 7722458 [A/G] NM_020777 SORCS2 Silent rs2285777 4 7726847 [A/G] NM_020777 SORCS2 Silent rs7679804 4 7729704 [T/G] NM_020777 SORCS2 Silent rs4689157 4 7730392 [A/G] NM_020777 SORCS2 Silent rs17466657 4 7730560 [A/G] NM_020777 SORCS2 Silent rs6821770 4 7732805 [A/G] NM_020777 SORCS2 Silent rs12233824 4 7733843 [A/G] NM_020777 SORCS2 Silent rs6843811 4 7736455 [A/G] NM_020777 SORCS2 Silent rs12499617 4 7736890 [A/G] NM_020777 SORCS2 Silent rs4689845 4 7737137 [A/G] NM_020777 SORCS2 Silent rs886374 4 7738369 [T/C] NM_020777 SORCS2 Silent rs6840685 4 7738730 [A/C] NM_020777 SORCS2 Silent rs16840963 4 7742352 [A/G] NM_020777 SORCS2 EXON Silent rs16840967 4 7742645 [A/G] NM_020777 SORCS2 EXON Silent rs17382228 4 7743135 [A/G] NM_020777 SORCS2 EXON Silent rs13442 4 7743283 [T/G] NM_020777 SORCS2 EXON Silent rs12498937 4 7744367 [T/G] NM_020777 SORCS2 EXON Silent rs2359608 4 7746390 [A/G] rs4689160 4 7746820 [T/C] rs4689848 4 7751894 [T/C] rs17466832 4 7752091 [A/C] rs4689851 4 7752580 [A/G] rs9968354 4 7753589 [T/C] rs17466860 4 7755379 [T/C] rs12501350 4 7756195 [T/C] NR_026892 AFAP1-AS1 Silent rs17382358 4 7757650 [A/C] NR_026892 AFAP1-AS1 Silent rs11729332 4 7759804 [T/C] NR_026892 AFAP1-AS1 Silent rs2285771 4 7761114 [A/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs2285770 4 7761211 [T/C] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs2285769 4 7761286 [T/C] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs2240057 4 7761657 [T/C] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs16841058 4 7762425 [T/C] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs11736215 4 7762502 [A/C] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs2285766 4 7762848 [A/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs2285764 4 7763161 [T/C] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs2285763 4 7763304 [T/C] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs2269852 4 7763584 [A/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs2269850 4 7763761 [A/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs2269849 4 7764148 [A/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs16841093 4 7764591 [A/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs2107182 4 7764821 [T/C] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs2240054 4 7765193 [A/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs16841112 4 7767318 [T/C] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 Silent,Silent,Silent rs13127069 4 7769493 [A/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 Silent,Silent,Silent rs2285761 4 7770723 [T/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Synonymous_R756R,Synonymous_R672R rs2018399 4 7771634 [A/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 Silent,Silent,Silent rs4234829 4 7772175 [A/C] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 Silent,Silent,Silent rs1557817 4 7772551 [A/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 Silent,Silent,Silent rs1557816 4 7772599 [T/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 Silent,Silent,Silent rs6828005 4 7774352 [A/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs2276967 4 7774610 [T/C] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Synonymous_A730A,Synonymous_A646A rs4689859 4 7777057 [A/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs2269878 4 7780344 [A/G] NR_026892,NM_001134647,NM_198595 AFAP1-AS1,AFAP1,AFAP1 EXON Silent,Silent,Silent rs16841209 4 7782434 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs10516189 4 7783286 [A/G] NM_001134647,NM_198595 AFAP1,AFAP1 EXON Synonymous_N533N,Silent rs13128495 4 7787049 [A/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs877707 4 7792662 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs10022249 4 7794001 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs10937862 4 7796922 [A/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs9683795 4 7800345 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs756255 4 7800699 [T/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs4689866 4 7801581 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs11728778 4 7802292 [A/G] NM_001134647,NM_198595 AFAP1,AFAP1 EXON Synonymous_T381T,Synonymous_T381T rs6821044 4 7802686 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs7376483 4 7804265 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs1106248 4 7807834 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs4689868 4 7809042 [A/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs4689869 4 7809472 [A/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs7693234 4 7809979 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs6846245 4 7810027 [A/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs6446622 4 7812674 [A/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs885262 4 7813170 [A/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs6844380 4 7815054 [A/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs6839506 4 7818646 [A/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs4234831 4 7822186 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs7685914 4 7831463 [A/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs6446629 4 7831977 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs4296679 4 7840696 [A/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs4580651 4 7841487 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs4689166 4 7841833 [A/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs4473655 4 7847468 [A/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs4361385 4 7852851 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs4619890 4 7853160 [A/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs4413405 4 7853361 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs28738908 4 7865324 [T/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs7441783 4 7866500 [A/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs28622214 4 7879440 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs7437940 4 7887500 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs17770177 4 7894887 [A/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs17770213 4 7896866 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs4478172 4 7902003 [A/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs1320074 4 7904111 [T/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs6831381 4 7904431 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs6824410 4 7906178 [A/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs13127935 4 7913961 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs12641498 4 7917574 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs6838291 4 7917806 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs1317111 4 7922502 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs10049998 4 7923973 [A/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs11733297 4 7928845 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs9991239 4 7929041 [A/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs1344223 4 7931635 [A/G] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs2385914 4 7931725 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs4696687 4 7939194 [T/C] NM_001134647,NM_198595 AFAP1,AFAP1 Silent,Silent rs6447872 4 7943106 [A/G] rs2891926 4 7947266 [T/C] rs4696833 4 7951137 [T/C] rs7685634 4 7951542 [A/G] rs10023401 4 7953583 [T/C] rs11732351 4 7955488 [T/C] rs6824093 4 7959029 [A/G] rs12512108 4 7959980 [A/G] rs7356321 4 7962856 [A/G] rs4696709 4 7966812 [A/G] rs4696886 4 7967683 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2292735 4 7967875 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1317285 4 7980298 [A/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7699715 4 7980652 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13133269 4 7984736 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16841523 4 7985977 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7677869 4 7986860 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16841530 4 7987764 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4696662 4 7991587 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4696726 4 7992632 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13129405 4 7992749 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4696663 4 7993976 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17772026 4 7997642 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16841542 4 8002391 [T/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11729198 4 8003927 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4696664 4 8008264 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16841552 4 8009737 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17180256 4 8009759 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13125250 4 8010112 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1317368 4 8011696 [A/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16841559 4 8012167 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4696729 4 8015421 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9990943 4 8017124 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2385895 4 8017759 [T/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4696666 4 8019447 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11932811 4 8020502 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11729381 4 8026176 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11726230 4 8026238 [T/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6833644 4 8027403 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17795172 4 8028937 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11942146 4 8031590 [T/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4696738 4 8045492 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6830813 4 8046433 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2385916 4 8047973 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1574414 4 8050056 [A/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10029338 4 8050343 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1320061 4 8051014 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7661897 4 8056846 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1320058 4 8060637 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4696669 4 8062202 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16841624 4 8062830 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6845573 4 8063501 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17178569 4 8064761 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6850368 4 8066573 [T/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10020078 4 8069318 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6829649 4 8070793 [T/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13132381 4 8071136 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9991680 4 8072684 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_001286688,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7660009 4 8074362 [T/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6842276 4 8075134 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1573843 4 8078157 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6856548 4 8080481 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6826670 4 8080573 [T/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7676911 4 8081871 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17178920 4 8083563 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6447849 4 8084560 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11724908 4 8085174 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11731965 4 8086173 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6817164 4 8086655 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2292739 4 8089598 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7674677 4 8097469 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12500841 4 8100171 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4464550 4 8100375 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17795478 4 8103323 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12647620 4 8104173 [A/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12511735 4 8105010 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16841721 4 8105320 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4696758 4 8106249 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12108540 4 8108027 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1878519 4 8110782 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1105616 4 8111117 [A/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17181205 4 8114525 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2138826 4 8116202 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1517523 4 8116432 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1125307 4 8117671 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11736271 4 8118328 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10938692 4 8118561 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1517525 4 8119937 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13122226 4 8120120 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4696763 4 8120666 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13144749 4 8121505 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17181631 4 8121799 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11936149 4 8122496 [T/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4696765 4 8125788 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1109531 4 8127714 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4696766 4 8131414 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1878521 4 8138645 [A/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4422405 4 8139958 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16841848 4 8142672 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4696769 4 8148159 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12506374 4 8154534 [T/C] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6816775 4 8156982 [T/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7660199 4 8157710 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1533508 4 8158352 [A/G] NM_001130087,NM_001130085,NM_001130086,NM_001130084,NM_032432,NM_001130083,NM_001130088 ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2,ABLIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10938694 4 8171401 [T/C] rs4696775 4 8177264 [A/G] rs13151241 4 8177703 [A/G] rs13152324 4 8178177 [A/G] rs753386 4 8189780 [T/C] rs1078701 4 8190219 [T/G] rs1678263 4 8199833 [T/C] rs753959 4 8201805 [A/C] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs1281120 4 8201828 [A/G] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs1281121 4 8202211 [A/G] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs1298472 4 8202841 [A/G] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs7677412 4 8204854 [A/G] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs2677605 4 8207083 [A/G] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 EXON Silent,Synonymous_P54P,Silent rs922521 4 8207810 [T/C] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs1281132 4 8209383 [A/G] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs1712316 4 8211624 [T/C] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs13152394 4 8212524 [T/C] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs1712287 4 8214636 [T/C] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs1281138 4 8220029 [A/G] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 EXON Silent,Missense_D291N,Missense_D215N rs1298145 4 8220400 [A/G] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs7660416 4 8222157 [T/C] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs1281142 4 8226488 [A/G] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs1292647 4 8228894 [T/C] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 EXON Silent,Synonymous_D491D,Synonymous_D415D rs1281152 4 8230456 [T/G] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs3756193 4 8233341 [T/C] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs3775905 4 8234381 [T/C] NR_134639,NM_018986,NM_001318480 SH3TC1,SH3TC1,SH3TC1 Silent,Silent,Silent rs1678336 4 8254784 [T/C] rs12186177 4 8258650 [T/C] rs4455399 4 8267897 [A/G] rs12639755 4 8280040 [T/C] NM_053044,NM_001297559 HTRA3,HTRA3 Silent,Silent rs7690786 4 8287563 [A/G] NM_053044,NM_001297559 HTRA3,HTRA3 Silent,Silent rs13140502 4 8291434 [T/G] NM_053044,NM_001297559 HTRA3,HTRA3 Silent,Silent rs13132047 4 8291918 [T/C] NM_053044,NM_001297559 HTRA3,HTRA3 Silent,Silent rs13132711 4 8292827 [A/C] NM_053044,NM_001297559 HTRA3,HTRA3 Silent,Silent rs4696793 4 8293356 [A/G] NM_053044,NM_001297559 HTRA3,HTRA3 Silent,Silent rs4235258 4 8293974 [T/C] NM_053044,NM_001297559 HTRA3,HTRA3 Silent,Silent rs4583740 4 8299162 [T/C] NM_053044 HTRA3 Silent rs4696796 4 8303557 [A/G] NM_053044 HTRA3 Silent rs4696798 4 8304097 [T/G] NM_053044 HTRA3 Silent rs13144236 4 8304137 [A/G] NM_053044 HTRA3 Silent rs4696802 4 8306091 [T/C] NM_053044 HTRA3 Silent rs6447857 4 8310257 [T/C] rs6818156 4 8311043 [A/G] rs4629434 4 8312324 [A/G] rs10023502 4 8313595 [A/G] rs6823378 4 8315938 [A/G] rs4696679 4 8316128 [T/G] rs12640734 4 8320126 [A/G] rs4696811 4 8321215 [A/C] rs6447860 4 8321456 [A/G] rs4696812 4 8321709 [A/G] rs1678330 4 8326441 [T/C] rs940141 4 8328353 [T/C] rs13144781 4 8329912 [A/G] rs754739 4 8331883 [A/C] rs754740 4 8331956 [A/C] rs1720011 4 8333694 [T/C] rs4696816 4 8334382 [A/G] rs2046027 4 8336320 [A/G] rs827018 4 8342853 [T/C] rs7682386 4 8350786 [A/C] rs1678272 4 8353829 [A/G] rs4696820 4 8354600 [T/C] rs4696821 4 8355890 [A/G] rs11933783 4 8356092 [A/G] rs13103277 4 8356253 [A/G] rs13129831 4 8357645 [A/G] rs899491 4 8367799 [A/C] rs7809 4 8368433 [A/G] NM_001101667,NM_003501 ACOX3,ACOX3 EXON Silent,Silent rs708244 4 8368604 [T/C] NM_001101667,NM_003501 ACOX3,ACOX3 EXON Silent,Silent rs735812 4 8371554 [T/C] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs747580 4 8373088 [T/C] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs747582 4 8373832 [T/G] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs11735859 4 8377058 [A/G] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs3796751 4 8378959 [T/G] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs4481223 4 8380149 [A/G] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs12504709 4 8383899 [T/C] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs7697154 4 8386107 [T/G] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs7696306 4 8389187 [A/G] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs1568692 4 8390646 [A/G] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs13434465 4 8390948 [T/C] NM_001101667,NM_003501 ACOX3,ACOX3 EXON Missense_D497N,Missense_D497N rs11934642 4 8394463 [T/C] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs6849528 4 8397625 [T/C] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs6810854 4 8397686 [A/G] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs4543095 4 8403036 [T/C] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs1880025 4 8404346 [A/G] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs10016221 4 8409237 [A/C] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs3775889 4 8416976 [T/C] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs11736150 4 8418801 [T/C] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs2688228 4 8421345 [T/C] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs2140336 4 8424831 [A/G] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs2631731 4 8429817 [A/G] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs2688245 4 8437635 [T/C] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs12511417 4 8440951 [T/C] NM_001101667,NM_003501 ACOX3,ACOX3 Silent,Silent rs12500188 4 8455455 [A/G] NM_001350233,NM_152544 TRMT44,TRMT44 Silent,Silent rs13129077 4 8458394 [A/G] NM_001350233,NM_152544 TRMT44,TRMT44 Silent,Silent rs2631749 4 8461517 [T/C] NM_001350233,NM_152544 TRMT44,TRMT44 Silent,Silent rs17202499 4 8472839 [T/C] NM_001350233,NM_152544 TRMT44,TRMT44 EXON Synonymous_N411N,Synonymous_N652N rs2631768 4 8473050 [A/G] NM_001350233,NM_152544 TRMT44,TRMT44 Silent,Silent rs2631735 4 8476118 [A/G] NM_001350233,NM_152544 TRMT44,TRMT44 Silent,Silent rs2631738 4 8479754 [A/G] rs2631746 4 8490934 [T/C] rs10001657 4 8498456 [A/G] rs13111630 4 8503281 [A/G] rs1949733 4 8503359 [A/G] rs16842427 4 8511590 [T/C] rs3103097 4 8512712 [A/G] rs3115397 4 8512889 [T/C] rs6823600 4 8513537 [T/C] rs3103075 4 8516605 [A/G] rs7665475 4 8518896 [T/C] rs13127781 4 8522221 [T/C] rs3103078 4 8524767 [T/C] rs7679494 4 8525665 [T/G] rs10461081 4 8527461 [A/G] rs3103079 4 8527968 [T/C] rs3103081 4 8528890 [T/C] rs4696710 4 8529240 [T/C] rs13140128 4 8529812 [A/C] rs6850810 4 8534283 [A/G] rs16842483 4 8535713 [A/G] rs3103082 4 8536360 [A/C] rs16842486 4 8537786 [T/C] rs3115401 4 8538007 [T/C] rs3103091 4 8538981 [T/C] rs3115403 4 8540729 [A/G] rs6447879 4 8541869 [T/C] rs3103086 4 8546816 [A/G] rs10805209 4 8549845 [T/C] rs4696842 4 8554894 [T/C] rs7682449 4 8556609 [T/C] rs17838916 4 8557853 [A/G] rs3115378 4 8557865 [T/C] rs11937563 4 8559576 [T/C] rs3103074 4 8562668 [T/C] rs4358385 4 8566213 [T/G] rs13108246 4 8567305 [T/C] rs11735274 4 8570973 [T/C] rs3115395 4 8574490 [T/C] rs6838103 4 8579149 [T/C] rs6838127 4 8579193 [T/C] rs1282 4 8579758 [T/C] rs2270269 4 8580952 [T/C] rs4235272 4 8584879 [A/G] NR_045511,NM_080819 GPR78,GPR78 Silent,Silent rs7696507 4 8586739 [T/C] NR_045511,NM_080819 GPR78,GPR78 Silent,Silent rs9685931 4 8589023 [A/G] NR_045511,NM_080819 GPR78,GPR78 EXON Silent,Missense_R342H rs9799717 4 8589263 [T/G] NR_045511,NM_080819 GPR78,GPR78 EXON Silent,Silent rs9799378 4 8589714 [A/G] NR_045511,NM_080819 GPR78,GPR78 EXON Silent,Silent rs4696853 4 8590511 [A/C] NR_045511,NM_080819 GPR78,GPR78 EXON Silent,Silent rs10938726 4 8596478 [A/C] NM_003652,NM_001014448,NM_001014447 CPZ,CPZ,CPZ Silent,Silent,Silent rs4696855 4 8597140 [T/C] NM_003652,NM_001014448,NM_001014447 CPZ,CPZ,CPZ Silent,Silent,Silent rs3822202 4 8604153 [T/C] NM_003652,NM_001014448,NM_001014447 CPZ,CPZ,CPZ Silent,Silent,Silent rs6834153 4 8606485 [A/G] NM_003652,NM_001014448,NM_001014447 CPZ,CPZ,CPZ Silent,Silent,Silent rs6838212 4 8606863 [T/C] NM_003652,NM_001014448,NM_001014447 CPZ,CPZ,CPZ Silent,Silent,Silent rs4696703 4 8607587 [A/G] NM_003652,NM_001014448,NM_001014447 CPZ,CPZ,CPZ Silent,Silent,Silent rs2302580 4 8608634 [T/C] NM_003652,NM_001014448,NM_001014447 CPZ,CPZ,CPZ Silent,Silent,Silent rs4696864 4 8614792 [T/C] NM_003652,NM_001014448,NM_001014447 CPZ,CPZ,CPZ Silent,Silent,Silent rs9991535 4 8616224 [T/C] NM_003652,NM_001014448,NM_001014447 CPZ,CPZ,CPZ EXON Missense_T490M,Missense_T364M,Missense_T501M rs2302569 4 8620464 [T/C] NM_003652,NM_001014448,NM_001014447 CPZ,CPZ,CPZ Silent,Silent,Silent rs1050464 4 8621386 [A/G] NM_003652,NM_001014448,NM_001014447 CPZ,CPZ,CPZ EXON Silent,Silent,Silent rs9685072 4 8639090 [A/G] rs9715724 4 8641696 [T/C] rs4696883 4 8644223 [A/G] rs9994747 4 8644457 [T/C] rs13147512 4 8645076 [T/C] rs4353891 4 8647103 [A/C] rs4077958 4 8647233 [T/C] rs4696891 4 8654825 [T/C] rs11724246 4 8658448 [T/C] rs3885959 4 8662633 [A/G] rs6838150 4 8663350 [A/G] rs10018816 4 8663630 [A/G] rs12508808 4 8670340 [A/G] rs13139568 4 8673840 [T/C] rs4696904 4 8674871 [A/G] rs7660783 4 8677043 [T/C] rs6854399 4 8678312 [A/G] rs7696626 4 8678693 [A/G] rs13106982 4 8681538 [T/C] rs7378503 4 8686173 [T/C] rs11944187 4 8687075 [A/C] rs6817108 4 8694389 [T/C] rs7672448 4 8699746 [A/G] rs6447893 4 8706113 [T/C] rs7440704 4 8709575 [T/C] rs7434698 4 8711399 [T/C] rs6832822 4 8712244 [A/G] rs10938742 4 8713015 [T/C] rs10938746 4 8721278 [T/G] rs11724850 4 8722340 [T/C] rs11734887 4 8726565 [A/G] rs4696925 4 8728783 [A/G] rs4696922 4 8729137 [T/C] rs10755200 4 8729471 [T/C] rs9760810 4 8731330 [A/G] rs13120358 4 8732053 [A/G] rs6858299 4 9371116 [T/C] rs9291627 4 9376566 [T/C] rs11727447 4 9394090 [A/C] rs7437149 4 9404812 [A/G] rs6854838 4 9423250 [T/G] rs11722202 4 9443894 [T/C] rs12501535 4 9456977 [T/C] rs6846314 4 9470222 [A/C] rs2086431 4 9509791 [T/C] rs9715299 4 9545932 [A/G] rs10001694 4 9551094 [A/G] rs2170252 4 9560062 [A/C] rs6820570 4 9579020 [A/G] rs13135278 4 9582422 [A/G] rs10049659 4 9586764 [T/C] rs6448858 4 9595918 [T/G] rs12645339 4 9596615 [T/C] rs12509677 4 9602724 [A/G] rs13115550 4 9651413 [T/C] rs7434744 4 9672688 [A/C] rs4554078 4 9701544 [A/G] rs9685887 4 9706342 [T/G] rs13136075 4 9714968 [A/G] rs12645989 4 9722133 [T/C] rs12647851 4 9724519 [T/C] rs7685513 4 9728599 [A/G] rs13127001 4 9731215 [A/G] rs10011621 4 9760239 [A/C] rs7655090 4 9765875 [A/G] rs10003216 4 9766749 [A/G] rs10001006 4 9788498 [T/C] rs1850744 4 9790712 [T/C] rs13106539 4 9797703 [T/C] rs16888799 4 9804556 [T/C] rs1519096 4 9805872 [T/C] rs12500086 4 9809859 [A/G] rs939132 4 9820883 [T/C] rs1878276 4 9824945 [A/G] rs4621429 4 9826870 [A/G] rs6837273 4 9829086 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs1401440 4 9832512 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs1401442 4 9839447 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs10939558 4 9844162 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs16889496 4 9845597 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs2176644 4 9849528 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs4697900 4 9859976 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs1106059 4 9861512 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs9684729 4 9862036 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs4697901 4 9863698 [T/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs4697903 4 9865426 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs11941148 4 9872364 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs2867394 4 9872475 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs16889932 4 9877640 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs1519098 4 9881158 [A/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs6834978 4 9881600 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs6847887 4 9883801 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs6449090 4 9884536 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs10805342 4 9887086 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs6818572 4 9889448 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs10939605 4 9896293 [A/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs4697909 4 9896760 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs4389579 4 9907604 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs16890728 4 9908833 [A/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs2280202 4 9909295 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs2280203 4 9909559 [T/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs2280204 4 9909850 [T/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs2280205 4 9909923 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 EXON Missense_P350L,Missense_P321L rs4336225 4 9911872 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs11934363 4 9912101 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs7674711 4 9916180 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs10805346 4 9920347 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs3733591 4 9922130 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 EXON Missense_R294H,Missense_R265H rs2012177 4 9924877 [T/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs881971 4 9930962 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs737267 4 9934744 [T/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs6855911 4 9935910 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs4447863 4 9938969 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs7675964 4 9941434 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs6449144 4 9944650 [T/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs2018643 4 9947121 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs1122141 4 9947278 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs7686538 4 9948077 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs4519796 4 9955936 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs9998811 4 9966477 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs13125646 4 9982330 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 EXON Synonymous_L189L,Synonymous_L160L rs6849736 4 9986783 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs3733590 4 9987226 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs3733589 4 9987324 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 EXON Synonymous_I168I,Synonymous_I139I rs7678012 4 9993772 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs6449213 4 9994215 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs3775948 4 9995182 [G/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs16891923 4 9996661 [A/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs13111638 4 9996890 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs4547795 4 9997060 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs10939650 4 9998440 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 EXON Synonymous_T125T,Synonymous_T96T rs13113918 4 9998493 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 EXON Synonymous_L108L,Synonymous_L79L rs7696536 4 10000236 [T/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs1014290 4 10001861 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs10023068 4 10004832 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs6853437 4 10005435 [A/G] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs6849273 4 10021595 [T/C] NM_020041,NM_001001290 SLC2A9,SLC2A9 Silent,Silent rs12509955 4 10024303 [T/C] NM_001001290 SLC2A9 Silent rs6820230 4 10027542 [T/C] NM_001001290 SLC2A9 EXON Missense_A17T rs10006397 4 10036140 [A/C] NM_001001290 SLC2A9 Silent rs10939665 4 10037628 [T/C] NM_001001290 SLC2A9 Silent rs10012779 4 10038112 [T/C] NM_001001290 SLC2A9 Silent rs6834555 4 10062326 [A/G] rs6820756 4 10062849 [A/G] rs12509082 4 10073785 [A/G] rs9926 4 10076860 [A/G] NM_005112,NM_017491 WDR1,WDR1 EXON Silent,Silent rs10516200 4 10082156 [A/C] NM_005112,NM_017491 WDR1,WDR1 Silent,Silent rs3756227 4 10087995 [A/C] NM_005112,NM_017491 WDR1,WDR1 Silent,Silent rs13441 4 10099340 [T/C] NM_005112,NM_017491 WDR1,WDR1 EXON Silent,Missense_I185V rs717615 4 10104670 [A/G] NM_005112,NM_017491 WDR1,WDR1 Silent,Silent rs3756224 4 10105739 [T/C] NM_005112,NM_017491 WDR1,WDR1 Silent,Silent rs3756223 4 10105797 [T/C] NM_005112,NM_017491 WDR1,WDR1 Silent,Silent rs4604059 4 10115065 [T/C] NM_005112,NM_017491 WDR1,WDR1 Silent,Silent rs12374320 4 10120609 [T/C] rs7699512 4 10125808 [T/C] rs7699671 4 10125874 [T/C] rs4619888 4 10126978 [A/C] rs4467562 4 10127141 [A/G] rs11724184 4 10127301 [A/G] rs16893786 4 10127918 [T/C] rs12501508 4 10131932 [A/G] rs881642 4 10133873 [T/C] rs881643 4 10134117 [A/G] rs17198113 4 10138470 [T/C] rs11732828 4 10138746 [T/C] rs4472137 4 10141506 [A/G] rs10024447 4 10145890 [A/G] rs4697715 4 10146654 [A/G] rs4235358 4 10147664 [A/G] rs6813385 4 10148828 [T/C] rs4697936 4 10149595 [T/G] rs737601 4 10153233 [T/C] rs6814532 4 10154554 [A/G] rs6851524 4 10155041 [A/C] rs11932627 4 10156177 [T/G] rs11929718 4 10156321 [A/C] rs2241465 4 10159020 [T/C] rs16894270 4 10165779 [T/G] rs1001216 4 10168849 [A/G] rs7686718 4 10171487 [T/C] rs6835689 4 10172479 [T/C] rs4697952 4 10173019 [A/G] rs10034405 4 10173696 [A/G] rs6449342 4 10179769 [A/G] rs6811287 4 10180823 [T/C] rs887733 4 10183108 [T/C] rs956312 4 10188326 [A/G] rs2868420 4 10202997 [A/G] rs11947517 4 10209251 [A/G] rs4697977 4 10210653 [T/C] rs13119183 4 10211012 [T/C] rs11734783 4 10240663 [T/C] rs917821 4 10241132 [A/C] rs1978274 4 10245087 [T/G] rs7667113 4 10246098 [T/C] rs11732042 4 10246448 [T/C] rs7661555 4 10250026 [T/C] rs9997918 4 10252199 [A/G] rs4697986 4 10258968 [A/G] rs4697988 4 10259959 [T/C] rs6449418 4 10271645 [T/C] rs7676442 4 10272591 [T/C] rs10489074 4 10272605 [A/C] rs10489072 4 10273244 [T/C] rs10939814 4 10273329 [T/C] rs1860910 4 10275470 [T/G] rs17473279 4 10276250 [A/G] rs12510549 4 10276467 [T/C] rs734662 4 10281141 [A/G] rs4698005 4 10283627 [T/C] rs10025247 4 10286082 [T/G] rs11728055 4 10296298 [A/C] rs9991653 4 10310495 [A/G] rs7436833 4 10311074 [T/C] rs714086 4 10313042 [A/G] rs6853389 4 10313460 [T/G] rs2024276 4 10318433 [A/C] rs993173 4 10323935 [T/C] rs9291683 4 10324160 [A/G] rs2192090 4 10335524 [T/C] rs10938761 4 10342723 [T/C] rs7654423 4 10344431 [T/C] rs17420450 4 10350765 [T/C] rs13145430 4 10350948 [T/C] rs4235361 4 10365093 [A/G] rs10938772 4 10375328 [A/G] rs4698043 4 10378602 [T/G] rs7677806 4 10383005 [T/C] rs9990427 4 10388313 [A/G] rs9990701 4 10388610 [A/G] rs6835730 4 10397327 [A/G] rs4389568 4 10398427 [A/G] rs7654258 4 10404512 [T/C] rs4643800 4 10407572 [T/G] rs7697246 4 10408757 [T/C] rs7656072 4 10409841 [A/G] rs3923393 4 10411638 [A/G] rs4610325 4 10413168 [T/C] rs7661365 4 10413908 [A/G] rs7683253 4 10419465 [T/C] rs4552452 4 10424323 [A/G] rs6811292 4 10432402 [T/C] rs4273464 4 10435344 [A/G] rs10003864 4 10437391 [T/C] rs35565862 4 10440704 [A/C] rs4422413 4 10443384 [T/G] NM_053042 ZNF518B EXON Silent rs3217 4 10444650 [T/C] NM_053042 ZNF518B EXON Silent rs10016022 4 10446906 [A/G] NM_053042 ZNF518B EXON Synonymous_D349D rs10016702 4 10447640 [A/G] NM_053042 ZNF518B EXON Missense_S105P rs10021506 4 10447848 [T/G] NM_053042 ZNF518B EXON Synonymous_P35P rs4339203 4 10462106 [A/G] rs6847730 4 10465712 [T/G] rs4333176 4 10475280 [A/C] rs6835433 4 10484987 [A/C] rs6836689 4 10485577 [A/G] rs10440278 4 10486083 [T/C] rs10488945 4 10490278 [T/G] NM_052964 CLNK EXON Silent rs13127079 4 10491719 [A/G] NM_052964 CLNK EXON Silent rs17467273 4 10500431 [T/C] NM_052964 CLNK Silent rs6834691 4 10501373 [A/G] NM_052964 CLNK Silent rs13109939 4 10501625 [T/C] NM_052964 CLNK Silent rs5000857 4 10502334 [A/G] NM_052964 CLNK Silent rs10488947 4 10503752 [A/G] NM_052964 CLNK Silent rs6833095 4 10506599 [A/G] NM_052964 CLNK Silent rs887112 4 10507984 [T/C] NM_052964 CLNK Silent rs13109005 4 10510881 [T/G] NM_052964 CLNK Silent rs1004327 4 10511483 [T/C] NM_052964 CLNK Silent rs1004329 4 10511996 [T/G] NM_052964 CLNK Silent rs13125670 4 10513072 [T/C] NM_052964 CLNK Silent rs10034180 4 10518525 [A/G] NM_052964 CLNK Silent rs13125086 4 10520693 [T/C] NM_052964 CLNK Silent rs977125 4 10522259 [A/C] NM_052964 CLNK Silent rs12641877 4 10528226 [A/G] NM_052964 CLNK Silent rs7657102 4 10529520 [A/G] NM_052964 CLNK Silent rs6856070 4 10545768 [A/G] NM_052964 CLNK Silent rs13112750 4 10547343 [T/C] NM_052964 CLNK Silent rs4698066 4 10549891 [A/G] NM_052964 CLNK Silent rs2159245 4 10550193 [A/G] NM_052964 CLNK Silent rs10938845 4 10551500 [T/C] NM_052964 CLNK Silent rs6848730 4 10551560 [T/G] NM_052964 CLNK Silent rs9992798 4 10554478 [A/G] NM_052964 CLNK Silent rs1974584 4 10557861 [T/C] NM_052964 CLNK Silent rs4698069 4 10559041 [A/G] NM_052964 CLNK Silent rs16869924 4 10567732 [T/C] NM_052964 CLNK EXON Missense_S65G rs17467553 4 10572867 [T/C] NM_052964 CLNK Silent rs17383040 4 10574056 [A/G] NM_052964 CLNK Silent rs6448095 4 10575214 [A/G] NM_052964 CLNK Silent rs12643937 4 10577980 [T/C] NM_052964 CLNK Silent rs10030578 4 10581872 [A/G] NM_052964 CLNK Silent rs11934521 4 10589553 [A/G] NM_052964 CLNK Silent rs10488949 4 10591448 [T/G] NM_052964 CLNK Silent rs1990272 4 10594679 [A/G] NM_052964 CLNK Silent rs6853762 4 10597423 [A/G] NM_052964 CLNK Silent rs4697760 4 10601918 [T/C] NM_052964 CLNK Silent rs2531185 4 10605821 [T/C] NM_052964 CLNK Silent rs2079685 4 10609118 [T/C] NM_052964 CLNK Silent rs17383444 4 10621516 [A/G] NM_052964 CLNK Silent rs2720363 4 10626314 [T/G] NM_052964 CLNK Silent rs12650571 4 10649456 [A/G] NM_052964 CLNK Silent rs10516207 4 10650693 [T/C] NM_052964 CLNK Silent rs11723092 4 10651891 [A/G] NM_052964 CLNK Silent rs35699234 4 10654346 [T/C] NM_052964 CLNK Silent rs4697768 4 10654997 [A/G] NM_052964 CLNK Silent rs12233843 4 10655218 [A/G] NM_052964 CLNK Silent rs13119277 4 10658129 [T/C] NM_052964 CLNK Silent rs6448177 4 10666272 [T/C] NM_052964 CLNK Silent rs3935222 4 10666634 [A/G] NM_052964 CLNK Silent rs13144136 4 10666909 [T/G] NM_052964 CLNK Silent rs12502030 4 10667476 [T/C] NM_052964 CLNK Silent rs13136927 4 10669522 [A/C] NM_052964 CLNK EXON Silent rs13115026 4 10670046 [A/G] NM_052964 CLNK Silent rs16871931 4 10673083 [A/C] NM_052964 CLNK Silent rs4582144 4 10674007 [T/C] NM_052964 CLNK Silent rs17268650 4 10674772 [T/C] NM_052964 CLNK Silent rs4697777 4 10675030 [T/C] NM_052964 CLNK Silent rs10033332 4 10679925 [A/G] NM_052964 CLNK Silent rs6827843 4 10688637 [A/C] rs4550919 4 10689292 [A/C] rs12510590 4 10690043 [T/C] rs13147855 4 10691942 [T/C] rs11721652 4 10692788 [T/C] rs6448182 4 10693222 [T/C] rs11725929 4 10694991 [T/G] rs4697648 4 10698265 [A/G] rs6819946 4 10702156 [T/C] rs11726285 4 10702568 [T/C] rs4697781 4 10704867 [A/G] rs4697650 4 10706422 [A/G] rs4549371 4 10707508 [T/C] rs11733408 4 10709812 [A/C] rs4452425 4 10711468 [A/C] rs9291444 4 10713674 [T/C] rs4561924 4 10714457 [T/C] rs4368598 4 10714656 [T/C] rs6829409 4 10725053 [A/G] rs16872571 4 10726853 [T/C] rs13116306 4 10727697 [T/C] rs11736462 4 10728396 [A/G] rs4697653 4 10728759 [A/G] rs13130534 4 10730199 [A/G] rs6833684 4 10731842 [T/C] rs12644305 4 10740267 [A/C] rs12650576 4 10744548 [T/G] rs10016050 4 10747573 [T/C] rs10007887 4 10749071 [T/C] rs4420973 4 10751743 [A/C] rs16872862 4 10753416 [A/G] rs12651622 4 10792729 [A/C] rs10938980 4 10804019 [T/C] rs9997174 4 10812968 [A/G] rs7691429 4 10831659 [T/C] rs13141536 4 10831736 [A/G] rs12696865 4 10833701 [T/G] rs1872090 4 10834255 [T/C] rs2869756 4 10835165 [T/G] rs16873628 4 10836045 [A/C] rs12645385 4 10840650 [T/C] rs4257647 4 10845207 [A/G] rs7673890 4 10847303 [A/G] rs2869749 4 10857992 [A/G] rs4074743 4 10867056 [T/G] rs11937733 4 10871539 [A/G] rs10516213 4 10871655 [A/C] rs4697799 4 10872167 [T/G] rs7667727 4 10874361 [A/G] rs13107834 4 10874933 [A/G] rs7698615 4 10877223 [A/G] rs1483660 4 10883658 [T/C] rs16874378 4 10886524 [A/G] rs11735551 4 10886810 [T/G] rs4697806 4 10892111 [T/C] rs10939028 4 10895077 [A/G] rs959233 4 10902159 [A/G] rs959234 4 10902379 [A/C] rs7660096 4 10903005 [A/G] rs2904192 4 10904684 [T/G] rs1105503 4 10905127 [A/G] rs10028469 4 10909225 [T/G] rs1384837 4 10910291 [T/G] rs12511310 4 10916915 [T/C] rs6818760 4 10920805 [A/C] rs17280854 4 10931542 [A/G] rs11935551 4 10931588 [T/G] rs4697808 4 10931705 [A/G] rs12643516 4 10939039 [T/C] rs12642366 4 10942197 [T/C] rs2869768 4 10943926 [T/C] rs7660235 4 10945449 [A/C] rs13124128 4 10949825 [T/C] rs10222862 4 10950989 [A/C] rs12510358 4 10951093 [T/C] rs13132998 4 10951486 [T/C] rs1466529 4 10952541 [A/G] rs6821267 4 10953205 [A/G] rs7683621 4 10961185 [T/C] rs10009111 4 10971423 [A/G] rs7675535 4 10972640 [T/C] rs7662952 4 10972886 [T/C] rs10516217 4 10973261 [A/G] rs10516218 4 10975416 [A/G] rs16876186 4 10975428 [T/C] rs2128866 4 10975896 [T/G] rs13143997 4 10980181 [T/C] rs10012274 4 10981163 [T/C] rs16876402 4 10986574 [A/G] rs2046359 4 10989008 [A/C] rs2128863 4 11002528 [A/G] rs875394 4 11011598 [T/G] rs9291483 4 11016733 [T/C] rs6448447 4 11019347 [T/G] rs4373155 4 11022799 [T/G] rs6846529 4 11025131 [T/C] rs17218817 4 11038268 [A/G] rs2904297 4 11040290 [T/C] rs6820330 4 11044254 [A/G] rs1110365 4 11049844 [A/G] rs1110364 4 11050130 [T/C] rs1039682 4 11050420 [A/G] rs7694991 4 11050853 [T/G] rs6846243 4 11053537 [A/G] rs16877315 4 11054542 [A/G] rs2063056 4 11055432 [T/C] rs4345174 4 11059843 [T/C] rs7698375 4 11060009 [A/G] rs10003771 4 11069107 [T/C] rs7697986 4 11069265 [A/G] rs7688919 4 11070470 [T/G] rs2202592 4 11071463 [A/G] rs7662758 4 11076268 [A/G] rs10516219 4 11080161 [T/G] rs4697836 4 11081033 [T/C] rs6822701 4 11085160 [A/G] rs6811589 4 11087189 [A/C] rs7655566 4 11087495 [T/C] rs16877810 4 11088906 [T/C] rs6837846 4 11091396 [T/G] rs4697839 4 11092841 [A/G] rs12501933 4 11099374 [A/C] rs6448494 4 11099518 [T/C] rs16878067 4 11100125 [T/G] rs16878079 4 11100735 [A/G] rs16878083 4 11100788 [A/G] rs8180283 4 11112475 [T/G] rs11944172 4 11112491 [A/G] rs16878196 4 11115865 [T/G] rs7694486 4 11116063 [T/C] rs9291494 4 11117827 [A/G] rs1506794 4 11119349 [A/G] rs1506793 4 11120280 [T/C] rs1506791 4 11120491 [A/C] rs10034047 4 11127123 [T/G] rs16878277 4 11127820 [T/C] rs16878282 4 11132123 [T/C] rs4697674 4 11133145 [A/G] rs16878305 4 11133904 [T/C] rs13152779 4 11142798 [A/G] rs12509327 4 11156010 [T/G] rs1876265 4 11162918 [T/G] rs6448544 4 11173785 [A/C] rs7684035 4 11174436 [T/C] rs7659670 4 11175752 [T/G] rs9291505 4 11177208 [T/C] rs1399334 4 11179846 [T/C] rs1399336 4 11179967 [T/G] rs10034712 4 11182041 [T/G] rs1506798 4 11186450 [A/G] rs2048069 4 11189001 [T/C] rs908107 4 11190557 [A/G] rs6835872 4 11191470 [T/G] rs1606724 4 11192848 [A/G] rs16878773 4 11199352 [A/G] rs16878828 4 11200787 [A/G] rs9683691 4 11201074 [T/C] rs13146400 4 11202360 [A/G] rs16878957 4 11208907 [T/G] rs16878962 4 11209409 [T/C] rs10006915 4 11210174 [A/C] rs10009253 4 11216238 [T/C] rs10031075 4 11216471 [A/G] rs4697681 4 11221352 [A/G] rs1003271 4 11224411 [T/C] rs1355967 4 11227687 [T/G] rs12511580 4 11229468 [A/G] rs1949275 4 11229690 [T/G] rs1355966 4 11231335 [A/G] rs11726519 4 11232290 [A/G] rs965001 4 11232758 [T/C] rs11727553 4 11233074 [T/G] rs12651349 4 11234427 [A/C] rs2203396 4 11234912 [T/G] rs16879350 4 11235402 [A/G] rs10034384 4 11235941 [A/G] rs4697859 4 11236408 [T/C] rs1548184 4 11244792 [T/C] rs2671878 4 11251244 [A/G] rs6840284 4 11252591 [T/C] rs782758 4 11258260 [T/G] rs782754 4 11264808 [A/G] rs782756 4 11266157 [A/G] rs1533338 4 11267586 [T/C] rs12643282 4 11275048 [T/C] rs6852625 4 11276716 [T/C] rs1609245 4 11285331 [A/G] rs1528079 4 11288642 [T/G] rs7663785 4 11289125 [T/C] rs11737841 4 11290673 [A/G] rs10805282 4 11291091 [T/G] rs11945818 4 11292775 [T/C] rs13104553 4 11295820 [T/C] rs9997158 4 11302032 [A/C] rs7666445 4 11302039 [A/G] rs17383637 4 11302189 [A/G] rs6829669 4 11302760 [A/G] rs4697869 4 11303176 [A/G] rs12501555 4 11303208 [T/C] rs2903016 4 11305539 [T/C] rs10488971 4 11307275 [A/C] rs6828885 4 11307669 [T/C] rs1029867 4 11311393 [A/G] rs1528078 4 11315928 [A/C] rs12512670 4 11317278 [T/G] rs17383790 4 11320411 [T/C] rs7699977 4 11327966 [T/C] rs1980381 4 11328556 [T/C] rs917683 4 11330075 [T/C] rs16880595 4 11333844 [A/G] rs981667 4 11337983 [T/C] rs1406077 4 11341565 [T/C] rs7676615 4 11344212 [A/G] rs917684 4 11352031 [A/G] rs1558402 4 11357481 [A/G] rs13112974 4 11364771 [T/C] rs12641904 4 11366016 [T/C] rs2109603 4 11372956 [A/C] rs4697879 4 11373795 [A/G] rs725432 4 11380054 [A/G] rs11731587 4 11390069 [A/G] rs6854770 4 11390743 [A/G] rs1528081 4 11398882 [T/C] rs1047389 4 11401087 [A/G] NM_005114 HS3ST1 EXON Synonymous_D181D rs4305508 4 11402508 [A/C] NM_005114 HS3ST1 Silent rs1406076 4 11403704 [T/C] NM_005114 HS3ST1 Silent rs16881446 4 11408585 [T/C] NM_005114 HS3ST1 Silent rs9999523 4 11412087 [A/G] NM_005114 HS3ST1 Silent rs16881495 4 11412625 [T/C] NM_005114 HS3ST1 Silent rs224463 4 11414037 [A/G] NM_005114 HS3ST1 Silent rs17423205 4 11415299 [A/G] NM_005114 HS3ST1 Silent rs17488994 4 11416758 [T/C] NM_005114 HS3ST1 Silent rs10939293 4 11417512 [A/G] NM_005114 HS3ST1 Silent rs16881554 4 11418534 [T/C] NM_005114 HS3ST1 Silent rs13135853 4 11419617 [A/G] NM_005114 HS3ST1 Silent rs2109600 4 11420619 [A/G] NM_005114 HS3ST1 Silent rs16881636 4 11421969 [A/G] NM_005114 HS3ST1 Silent rs7660531 4 11424898 [T/C] NM_005114 HS3ST1 Silent rs7660733 4 11425012 [T/C] NM_005114 HS3ST1 Silent rs12054490 4 11425821 [A/G] NM_005114 HS3ST1 Silent rs224489 4 11432165 [T/G] rs11936371 4 11435516 [A/G] rs224484 4 11439946 [T/C] rs224481 4 11441634 [A/G] rs411035 4 11448182 [T/C] rs17424739 4 11449199 [T/C] rs17490471 4 11449278 [A/G] rs402575 4 11455518 [T/C] rs224474 4 11459738 [T/G] rs16882139 4 11460840 [A/G] rs224470 4 11461954 [A/G] rs13137776 4 11464975 [A/G] rs7699705 4 11467103 [A/G] rs6822160 4 11468244 [T/C] rs11733131 4 11470385 [A/G] rs737488 4 11470916 [T/C] rs10023768 4 11474624 [T/C] rs9291554 4 11475911 [A/G] rs11735501 4 11481304 [A/C] rs2029799 4 11483569 [T/C] rs12163751 4 11487322 [A/G] rs16882615 4 11489979 [T/C] rs10004232 4 11498145 [T/C] rs923997 4 11500166 [A/G] rs17236493 4 11500214 [T/C] rs1874238 4 11503860 [A/C] rs13139849 4 11506753 [T/C] rs6847037 4 11507052 [T/G] rs4916640 4 11507454 [A/C] rs2088131 4 11511291 [T/C] rs1565924 4 11511452 [A/G] rs1565928 4 11511779 [T/G] rs17316209 4 11512336 [A/G] rs11725667 4 11513562 [A/G] rs9993962 4 11515688 [A/G] rs9997161 4 11516724 [A/G] rs6848315 4 11517436 [A/G] rs10003762 4 11519011 [A/G] rs11729702 4 11521906 [A/G] rs12508213 4 11524263 [A/C] rs6835462 4 11527822 [T/G] rs6448766 4 11529707 [A/C] rs12647573 4 11531314 [A/G] rs1603186 4 11537238 [T/C] rs10155331 4 11538001 [T/C] rs7687011 4 11538947 [T/C] rs956469 4 11546275 [T/G] rs1032502 4 11547106 [A/G] rs6846137 4 11547681 [A/G] rs6448784 4 11556893 [T/C] rs10049912 4 11571164 [T/C] rs10488991 4 11577136 [T/G] rs2215232 4 11594112 [T/C] rs11728997 4 11596870 [A/G] rs2052044 4 11600333 [T/C] rs12506708 4 11601925 [T/C] rs17427761 4 11605860 [T/C] rs16884475 4 11605925 [A/G] rs10939361 4 11606915 [T/C] rs13151936 4 11614944 [A/G] rs10032590 4 11617783 [T/C] rs16884697 4 11618991 [A/G] rs6842740 4 11619288 [T/C] rs723563 4 11621121 [T/C] rs3886917 4 11621242 [T/C] rs11730207 4 11621877 [T/C] rs11730600 4 11623160 [A/G] rs6822439 4 11623872 [A/G] rs6845061 4 11624085 [A/G] rs9884312 4 11625588 [A/G] rs2865155 4 11628238 [A/G] rs6448799 4 11630049 [T/C] rs11728092 4 11631446 [A/G] rs13106661 4 11633455 [A/C] rs10009834 4 11635856 [T/C] rs966240 4 11642534 [T/C] rs1860292 4 11651556 [A/G] rs4397010 4 11664714 [T/C] rs7671189 4 11674661 [T/C] rs12649160 4 11677334 [A/G] rs1029747 4 11684751 [A/G] rs2870411 4 11692300 [A/C] rs6831780 4 11700529 [T/C] rs7696515 4 11701193 [A/G] rs11729868 4 11721992 [T/C] rs2279546 4 11732810 [A/C] rs3912887 4 11734841 [A/C] rs16886047 4 11736299 [T/C] rs6825825 4 11743843 [A/C] NR_146995 LINC02360 Silent rs993835 4 11744388 [A/C] NR_146995 LINC02360 Silent rs7654642 4 11747298 [T/C] NR_146995 LINC02360 Silent rs1388867 4 11754426 [T/C] NR_146995 LINC02360 Silent rs7442496 4 11754463 [T/G] NR_146995 LINC02360 Silent rs9291579 4 11755497 [T/C] NR_146995 LINC02360 Silent rs7699210 4 11759562 [T/C] NR_146995 LINC02360 Silent rs6845480 4 11760145 [T/G] NR_146995 LINC02360 Silent rs10031209 4 11773427 [T/C] rs923747 4 11775089 [T/C] rs6448823 4 11779280 [A/G] rs12639854 4 11786048 [A/G] rs16886144 4 11789355 [T/C] rs12505790 4 11792289 [T/C] rs7661409 4 11816679 [A/G] rs6448833 4 11819371 [T/C] rs1489473 4 11825987 [A/G] rs16886280 4 11845784 [T/G] rs10024612 4 11850963 [T/C] rs6448841 4 11861566 [A/C] rs17256075 4 11864538 [A/C] rs993091 4 11865461 [T/C] rs12506582 4 11865749 [T/G] rs12645979 4 11868097 [T/C] rs2200819 4 11868786 [A/C] rs12510141 4 11869456 [A/G] rs17322411 4 11870144 [T/C] rs6840259 4 11872010 [T/C] rs17256627 4 11873033 [T/C] rs6843251 4 11873630 [A/G] rs11934095 4 11884262 [A/G] rs9996394 4 11887483 [T/C] rs2866059 4 11892822 [T/C] rs4394018 4 11900932 [T/C] rs6852116 4 11901216 [T/C] rs17323516 4 11904548 [T/G] rs16886377 4 11909465 [T/C] rs16886385 4 11910523 [T/C] rs1387459 4 11911000 [T/C] rs13111622 4 11912625 [A/C] rs17258155 4 11913343 [T/C] rs10084803 4 11917328 [T/C] rs2171726 4 11922712 [T/C] rs11939914 4 11924046 [A/G] rs11725886 4 11926778 [A/G] rs10939381 4 11927652 [T/C] rs10939383 4 11938394 [A/G] rs10939384 4 11938729 [A/G] rs10026111 4 11948408 [A/G] rs10213500 4 11948435 [T/C] rs10213502 4 11948654 [A/G] rs10034012 4 11949791 [T/C] rs11933846 4 11950887 [A/G] rs9685781 4 11954738 [A/G] rs13149855 4 11955722 [A/C] rs16886480 4 11956720 [T/C] rs7696250 4 11977042 [A/C] rs13133185 4 11981872 [T/C] rs7666669 4 11982994 [A/G] rs16886509 4 11983193 [A/G] rs6836003 4 11984196 [T/C] rs1372887 4 12000904 [T/C] rs12639801 4 12008411 [A/G] rs10212892 4 12014109 [T/C] rs6448852 4 12017993 [T/C] rs16886566 4 12028032 [T/C] rs11721877 4 12036029 [A/C] rs7672776 4 12050985 [A/G] rs16886607 4 12069337 [A/G] rs1025877 4 12074137 [A/G] rs16886620 4 12077060 [T/C] rs1479273 4 12083991 [T/C] rs12641414 4 12088133 [T/C] rs16886736 4 12090970 [T/G] rs13152023 4 12098774 [A/G] rs6810659 4 12099307 [A/C] rs1479279 4 12099335 [A/G] rs4834882 4 12108239 [T/C] rs1382751 4 12138827 [T/C] rs1382752 4 12143367 [A/G] rs1479266 4 12150124 [A/C] rs10470840 4 12154213 [T/C] rs7670873 4 12171491 [T/C] rs6858365 4 12172669 [T/C] rs6448866 4 12176643 [T/C] rs724317 4 12180791 [A/C] rs2127270 4 12182361 [T/G] rs35429502 4 12186039 [T/C] rs10516248 4 12186445 [A/C] rs13114953 4 12188297 [T/C] rs12331250 4 12196573 [A/C] rs1982655 4 12212637 [T/C] rs10939415 4 12216880 [T/C] rs11931935 4 12218075 [T/C] rs13108906 4 12218164 [A/C] rs16886803 4 12220243 [T/C] rs10440293 4 12223752 [T/C] rs2124141 4 12242026 [T/C] NR_125910 LINC02270 Silent rs1842160 4 12246716 [A/G] NR_125910 LINC02270 Silent rs1454884 4 12256501 [T/C] rs1454883 4 12258122 [T/C] rs1454867 4 12262020 [T/C] rs16886866 4 12267803 [A/C] rs2061062 4 12267885 [A/G] rs10516251 4 12274324 [A/G] rs1454870 4 12275642 [A/C] rs2866454 4 12285990 [A/G] rs10019282 4 12293571 [T/G] rs1902137 4 12296574 [A/G] rs4834885 4 12297358 [T/C] rs12499121 4 12297535 [T/C] rs1869644 4 12303661 [T/C] rs10018554 4 12305958 [T/C] rs1454878 4 12306268 [T/C] rs4834974 4 12306820 [T/C] rs4834886 4 12310722 [T/C] rs7681103 4 12312917 [A/G] rs11722471 4 12313033 [A/G] rs1902138 4 12317013 [T/G] rs1454882 4 12317409 [A/G] rs7699666 4 12320676 [T/C] rs7677522 4 12320759 [A/C] rs10516252 4 12322014 [A/G] rs1378233 4 12328063 [A/G] rs10213284 4 12329819 [A/G] rs16886962 4 12344593 [T/C] rs12643322 4 12349114 [T/C] rs6822254 4 12356550 [T/C] rs17356154 4 12359809 [A/G] rs16886989 4 12360348 [T/C] rs6448887 4 12361202 [A/G] rs1454888 4 12374586 [A/G] rs1454889 4 12374820 [T/G] rs10516249 4 12375057 [T/C] rs9283696 4 12375400 [T/C] rs9291588 4 12375716 [T/C] rs2866457 4 12378886 [A/G] rs6414745 4 12381591 [A/G] rs4377605 4 12383947 [A/G] rs11942175 4 12395247 [T/C] rs6855410 4 12405180 [A/C] rs6817176 4 12418506 [T/C] rs13435388 4 12420636 [A/G] rs6448889 4 12420960 [A/G] rs7656574 4 12421862 [T/C] rs4447880 4 12436544 [T/C] rs7673955 4 12440385 [T/C] rs6824314 4 12454605 [T/C] rs6812909 4 12470500 [T/C] rs6819663 4 12471651 [A/G] rs2219943 4 12526377 [T/C] rs1351455 4 12526515 [T/G] rs6847440 4 12543102 [A/G] rs6448916 4 12546096 [T/C] rs16887136 4 12546987 [T/C] rs6851677 4 12552453 [A/G] rs6448925 4 12554693 [A/G] rs16887189 4 12557358 [T/C] rs16887206 4 12563037 [A/C] rs977629 4 12569163 [A/G] rs10939438 4 12570464 [A/G] rs6825629 4 12573378 [A/G] rs10029959 4 12578444 [A/C] rs17360757 4 12579381 [A/C] rs17360778 4 12579382 [A/G] rs6857588 4 12585408 [A/G] rs17295533 4 12590868 [A/G] rs17295743 4 12593370 [A/G] rs4571345 4 12593395 [T/C] rs6448932 4 12595799 [T/G] rs6448933 4 12596193 [T/C] rs7664245 4 12599135 [A/C] rs12508370 4 12605378 [T/C] rs7680227 4 12606923 [A/G] rs7659827 4 12607338 [A/G] rs17362130 4 12613974 [A/G] rs10516256 4 12615127 [A/C] rs4834846 4 12615274 [A/G] rs13149659 4 12625380 [T/G] rs1545817 4 12627162 [T/G] rs10032940 4 12631827 [T/G] rs6839361 4 12633072 [A/G] rs6822083 4 12634511 [A/C] rs13141338 4 12636408 [T/C] rs6842616 4 12638121 [T/C] rs7692229 4 12639728 [A/G] rs7687042 4 12642861 [T/G] rs17363850 4 12662979 [A/G] rs11946420 4 12663829 [T/C] rs10939444 4 12664089 [A/G] rs10516260 4 12671583 [T/C] rs11724617 4 12673985 [A/G] rs1402033 4 12678480 [T/G] rs2222310 4 12679774 [T/C] rs13151965 4 12679993 [T/C] rs7690844 4 12682297 [A/G] rs13123654 4 12683518 [A/C] rs17299409 4 12690183 [T/C] rs1356832 4 12690198 [T/C] rs1520296 4 12697432 [T/C] rs2903351 4 12707180 [T/C] rs9291595 4 12712139 [T/G] rs10031132 4 12723676 [T/C] rs7663013 4 12723707 [T/C] rs11728601 4 12725164 [T/G] rs13136382 4 12733389 [T/C] rs11726001 4 12734687 [A/C] rs9291598 4 12736121 [T/C] rs9884719 4 12736715 [A/G] rs10022602 4 12741313 [T/C] rs7692324 4 12757442 [T/G] rs2903395 4 12758617 [A/C] rs2866811 4 12763137 [A/G] rs16887552 4 12773994 [A/C] rs6810977 4 12776391 [T/C] rs6448952 4 12776895 [A/G] rs17366799 4 12778849 [A/G] rs6857474 4 12782701 [T/C] rs11731395 4 12789828 [T/C] rs12507532 4 12790058 [T/C] rs11728626 4 12791971 [T/C] rs17301479 4 12793263 [T/C] rs13105543 4 12795135 [A/C] rs11728489 4 12797555 [T/C] rs2711564 4 12801334 [T/G] rs807423 4 12802055 [T/C] rs6849099 4 12803879 [A/G] rs807418 4 12808091 [A/G] rs16887595 4 12809589 [A/G] rs7662165 4 12811827 [A/G] rs2540818 4 12817157 [T/G] rs2540821 4 12819018 [T/C] rs2540823 4 12827562 [T/C] rs11723612 4 12827751 [T/C] rs2540825 4 12828247 [T/G] rs2540834 4 12838429 [T/C] rs2711547 4 12839087 [A/G] rs2540841 4 12847075 [A/G] rs2110898 4 12859756 [T/C] rs10939459 4 12862476 [A/G] rs17515558 4 12875351 [T/C] rs9291601 4 12876257 [A/G] rs12502445 4 12881391 [A/C] rs223914 4 12888409 [T/C] rs7697105 4 12888995 [A/G] rs7697521 4 12889196 [A/G] rs12648564 4 12894741 [A/G] rs981269 4 12897698 [T/C] rs16887775 4 12902074 [A/G] rs190110 4 12914467 [T/C] rs7675207 4 12914709 [T/C] rs1513935 4 12919993 [T/C] rs17518096 4 12921186 [T/C] rs1513955 4 12924466 [T/C] rs4834855 4 12928197 [T/C] rs670400 4 12931444 [T/G] rs672282 4 12931901 [A/G] rs223997 4 12934281 [T/C] rs6811193 4 12935474 [A/G] rs170369 4 12938532 [T/C] rs7679576 4 12938795 [A/G] rs1154862 4 12939091 [T/C] rs6850802 4 12940751 [A/G] rs728171 4 12942258 [T/G] rs10489033 4 12960502 [A/G] rs16887898 4 12960713 [T/C] rs223975 4 12962308 [A/G] rs223976 4 12962421 [A/G] rs763318 4 12963574 [A/G] rs7676689 4 12965300 [T/C] rs4108065 4 12965868 [A/G] rs223982 4 12967160 [A/G] rs223989 4 12972256 [A/C] rs2867020 4 12993951 [A/C] rs2867021 4 12994201 [A/C] rs4834856 4 12997151 [T/C] rs10516262 4 13000803 [A/G] rs1828760 4 13001452 [A/G] rs2673423 4 13002341 [T/C] rs1040057 4 13002905 [A/G] rs1040056 4 13003758 [T/G] rs2673422 4 13003905 [A/G] rs1913704 4 13005874 [A/C] rs1040055 4 13006337 [A/G] rs2056116 4 13009987 [A/G] rs2621243 4 13010694 [T/C] rs1947850 4 13020235 [A/C] rs1949241 4 13021063 [A/G] rs12504391 4 13022635 [T/C] rs7679886 4 13026562 [T/C] rs1513947 4 13026792 [T/C] rs1513948 4 13027245 [A/G] rs1399019 4 13028973 [A/G] rs16887980 4 13029623 [T/C] rs4834860 4 13030876 [A/G] rs1318883 4 13036900 [A/C] rs981561 4 13037163 [A/G] rs1973655 4 13037938 [A/G] rs1947851 4 13038094 [A/C] rs11942249 4 13047032 [T/C] rs2673420 4 13047066 [T/G] rs1515407 4 13048129 [A/C] rs7678073 4 13048594 [T/G] rs1904794 4 13049139 [A/G] rs1913699 4 13052713 [A/C] rs2127657 4 13056251 [A/G] rs2621250 4 13056423 [T/C] rs2903472 4 13056521 [A/C] rs6837034 4 13056540 [T/C] rs481266 4 13057870 [A/C] rs2127660 4 13067251 [A/C] rs492316 4 13068686 [T/C] rs474076 4 13070446 [A/G] rs4834919 4 13072361 [T/C] rs560164 4 13073411 [A/G] rs566737 4 13073618 [A/C] rs481012 4 13074010 [T/G] rs16888112 4 13075100 [T/C] rs16888117 4 13077746 [T/C] rs6848051 4 13080111 [A/G] rs481213 4 13080633 [T/C] rs10939464 4 13081396 [A/G] rs496099 4 13082236 [A/G] rs497117 4 13082344 [T/C] rs541574 4 13092007 [T/C] rs11945548 4 13092297 [T/G] rs4458470 4 13093944 [A/C] rs1021873 4 13094261 [A/G] rs512244 4 13098882 [T/C] rs13122273 4 13102351 [T/G] rs9291606 4 13102477 [T/G] rs559283 4 13106197 [T/C] rs524129 4 13107182 [T/C] rs9991988 4 13111719 [T/C] rs4834921 4 13116181 [T/C] rs525216 4 13118169 [T/C] rs510171 4 13120238 [T/C] rs573332 4 13122535 [T/C] rs568118 4 13124794 [T/C] rs6841445 4 13127303 [T/C] rs536983 4 13130251 [T/G] rs6836652 4 13130999 [A/G] rs11935085 4 13131206 [A/C] rs518608 4 13139990 [T/G] rs519639 4 13140134 [T/C] rs509175 4 13142107 [T/C] rs490325 4 13147622 [A/G] rs503506 4 13149122 [A/G] rs16888269 4 13164420 [A/C] rs562920 4 13167596 [T/C] rs3101937 4 13168944 [A/G] rs16888291 4 13171640 [T/C] rs17314336 4 13181596 [T/C] rs10013514 4 13182254 [A/G] rs7685975 4 13182756 [A/G] rs10012046 4 13184283 [T/C] rs870835 4 13193295 [T/C] rs17315056 4 13201728 [A/G] rs10008923 4 13213672 [A/G] rs4574432 4 13220338 [A/G] rs6838271 4 13221390 [T/C] rs733048 4 13242797 [A/G] rs6847194 4 13245646 [T/C] rs16888414 4 13257662 [T/C] rs16888421 4 13261188 [A/C] rs16888428 4 13264141 [A/G] rs6852153 4 13265092 [A/C] rs11729455 4 13265492 [T/G] rs10022758 4 13265681 [A/G] rs7654928 4 13266612 [A/G] rs16888449 4 13269293 [T/C] rs16888451 4 13269649 [A/G] rs16888456 4 13270656 [T/C] rs16888468 4 13276652 [T/C] rs1014335 4 13280762 [T/C] rs4130 4 13280804 [A/G] rs17468716 4 13284177 [A/G] rs3213705 4 13297604 [A/G] rs6448976 4 13300269 [T/C] rs6851825 4 13302267 [A/G] rs16888511 4 13303269 [T/C] rs9995899 4 13310431 [A/G] rs16898654 4 13339453 [A/G] rs11934241 4 13340029 [A/G] rs10016671 4 13359047 [T/C] rs11947530 4 13360630 [T/C] rs10003958 4 13370308 [T/C] NM_001017979,NM_004249,NM_001159601 RAB28,RAB28,RAB28 Silent,Silent,Silent rs2109590 4 13377286 [T/C] NM_001017979,NM_004249,NM_001159601 RAB28,RAB28,RAB28 Silent,Silent,Silent rs10939477 4 13391279 [T/C] NM_001017979,NM_004249,NM_001159601 RAB28,RAB28,RAB28 Silent,Silent,Silent rs10001262 4 13393883 [T/C] NM_001017979,NM_004249,NM_001159601 RAB28,RAB28,RAB28 Silent,Silent,Silent rs10805318 4 13439808 [T/C] NM_001017979,NM_004249,NM_001159601 RAB28,RAB28,RAB28 Silent,Silent,Silent rs4518326 4 13459953 [A/G] NM_001017979,NM_004249,NM_001159601 RAB28,RAB28,RAB28 Silent,Silent,Silent rs10516268 4 13478859 [A/G] NM_001017979,NM_004249,NM_001159601 RAB28,RAB28,RAB28 Silent,Silent,Silent rs10030573 4 13484420 [T/C] NM_001017979,NM_004249,NM_001159601 RAB28,RAB28,RAB28 Silent,Silent,Silent rs7695513 4 13490658 [A/G] rs10489095 4 13502412 [A/G] rs2075050 4 13526386 [A/G] rs10034452 4 13530824 [T/G] NR_034054 LINC01097 Silent rs1157946 4 13534408 [T/C] rs10939485 4 13538956 [A/G] rs758973 4 13539373 [T/G] rs12501307 4 13540518 [A/G] rs1476211 4 13542036 [A/G] rs3822226 4 13542674 [A/G] NM_001189 NKX3-2 EXON Silent rs1379086 4 13555006 [T/C] rs13105197 4 13559103 [A/C] rs4698247 4 13561643 [T/C] rs12651430 4 13566458 [T/G] rs28504414 4 13569859 [A/G] rs10001811 4 13570152 [T/C] rs2052159 4 13578405 [A/G] NM_148894 BOD1L1 Silent rs7695814 4 13578682 [A/G] NM_148894 BOD1L1 Silent rs16888850 4 13580611 [T/C] NM_148894 BOD1L1 Silent rs10005546 4 13580676 [A/C] NM_148894 BOD1L1 Silent rs10022851 4 13581927 [T/C] NM_148894 BOD1L1 Silent rs17745075 4 13584108 [A/G] NM_148894 BOD1L1 Silent rs758975 4 13593336 [A/G] NM_148894 BOD1L1 Silent rs1013300 4 13595559 [A/G] NM_148894 BOD1L1 Silent rs3822227 4 13601443 [T/C] NM_148894 BOD1L1 EXON Missense_G2361S rs17745676 4 13604182 [T/C] NM_148894 BOD1L1 EXON Missense_T1448A rs2035820 4 13615174 [A/G] NM_148894 BOD1L1 EXON Missense_T429M rs4235372 4 13625648 [T/C] NM_148894 BOD1L1 Silent rs4698090 4 13625902 [T/G] NM_148894 BOD1L1 Silent rs16888892 4 13643437 [A/G] rs1388300 4 13677430 [T/C] NR_121681 LINC01182 Silent rs10017022 4 13681606 [A/G] NR_121681 LINC01182 Silent rs1586761 4 13684994 [A/G] NR_121681 LINC01182 Silent rs6836789 4 13689232 [A/G] NR_121681 LINC01182 Silent rs2058579 4 13689343 [T/G] NR_121681 LINC01182 Silent rs1491262 4 13692300 [T/C] NR_121681 LINC01182 Silent rs10939499 4 13697961 [A/G] NR_121681 LINC01182 Silent rs6850309 4 13699931 [A/C] NR_121681 LINC01182 Silent rs1491267 4 13703081 [T/C] NR_121681 LINC01182 Silent rs11727013 4 13706858 [T/C] NR_121681 LINC01182 Silent rs16888984 4 13708614 [T/C] NR_121681 LINC01182 Silent rs6835289 4 13710530 [A/C] NR_121681 LINC01182 Silent rs13141860 4 13712206 [A/C] NR_121681 LINC01182 Silent rs10025528 4 13713538 [T/C] NR_121681 LINC01182 Silent rs875373 4 13715903 [A/G] NR_121681 LINC01182 Silent rs10489085 4 13717262 [A/G] NR_121681 LINC01182 Silent rs13120921 4 13717471 [T/C] NR_121681 LINC01182 Silent rs10084768 4 13719489 [A/G] NR_121681 LINC01182 Silent rs16889099 4 13732086 [T/C] NR_121681 LINC01182 Silent rs7656112 4 13732433 [T/C] NR_121681 LINC01182 Silent rs9994682 4 13733371 [T/C] NR_121681 LINC01182 Silent rs7688193 4 13735895 [A/G] NR_121681 LINC01182 Silent rs759261 4 13737915 [A/G] NR_121681 LINC01182 Silent rs4698460 4 13749408 [T/G] NR_121681 LINC01182 Silent rs10489086 4 13753317 [A/G] NR_121681 LINC01182 Silent rs2270279 4 13755011 [T/G] NR_121681 LINC01182 Silent rs16889152 4 13760844 [A/G] NR_121681 LINC01182 Silent rs3931695 4 13761712 [A/G] NR_121681 LINC01182 Silent rs741217 4 13767656 [A/C] NR_121681 LINC01182 Silent rs10000713 4 13780048 [T/C] NR_121681 LINC01182 Silent rs1491250 4 13780176 [T/C] NR_121681 LINC01182 Silent rs1472092 4 13782594 [T/C] NR_121681 LINC01182 Silent rs1158808 4 13783235 [T/C] NR_121681 LINC01182 Silent rs1008218 4 13785225 [T/G] NR_121681 LINC01182 Silent rs13112901 4 13787277 [A/G] NR_121681 LINC01182 Silent rs7441080 4 13788219 [A/G] NR_121681 LINC01182 Silent rs1019271 4 13788316 [A/G] NR_121681 LINC01182 Silent rs1016029 4 13797533 [A/C] NR_121681 LINC01182 Silent rs716424 4 13798314 [A/C] NR_121681 LINC01182 Silent rs16889224 4 13798796 [T/C] NR_121681 LINC01182 Silent rs17754182 4 13799411 [T/C] NR_121681 LINC01182 Silent rs10939508 4 13799857 [T/C] NR_121681 LINC01182 Silent rs7684636 4 13807335 [T/C] NR_121681 LINC01182 Silent rs10489088 4 13808360 [A/G] NR_121681 LINC01182 Silent rs10012159 4 13809978 [A/G] NR_121681 LINC01182 Silent rs10007245 4 13812406 [T/C] NR_121681 LINC01182 Silent rs10939516 4 13815155 [A/G] NR_121681 LINC01182 Silent rs7697386 4 13818881 [A/G] NR_121681 LINC01182 Silent rs7660348 4 13820617 [T/C] NR_121681 LINC01182 Silent rs9784575 4 13820801 [A/G] NR_121681 LINC01182 Silent rs7686779 4 13824622 [T/C] NR_121681 LINC01182 Silent rs4395500 4 13824647 [T/C] NR_121681 LINC01182 Silent rs887924 4 13825610 [T/C] NR_121681 LINC01182 Silent rs13151645 4 13831792 [T/C] NR_121681 LINC01182 Silent rs887925 4 13833161 [T/C] NR_121681 LINC01182 Silent rs878098 4 13833459 [A/C] NR_121681 LINC01182 Silent rs2160118 4 13840539 [T/C] NR_121681 LINC01182 Silent rs2160120 4 13841321 [T/G] NR_121681 LINC01182 Silent rs6854091 4 13849195 [T/C] NR_121681 LINC01182 Silent rs1990552 4 13853053 [A/G] NR_121681 LINC01182 Silent rs4698178 4 13855897 [A/G] NR_121681 LINC01182 Silent rs7691604 4 13858393 [T/C] NR_121681 LINC01182 Silent rs1861135 4 13861249 [A/G] NR_121681 LINC01182 Silent rs7669912 4 13867556 [A/C] NR_121681 LINC01182 Silent rs11724465 4 13870359 [T/G] NR_121681 LINC01182 Silent rs7690022 4 13872720 [T/C] NR_121681 LINC01182 Silent rs17755724 4 13874388 [A/G] NR_121681 LINC01182 Silent rs6824694 4 13874500 [A/G] NR_121681 LINC01182 Silent rs2867578 4 13877759 [T/C] NR_121681 LINC01182 Silent rs1157531 4 13882785 [T/C] NR_121681 LINC01182 Silent rs807764 4 13883763 [A/G] NR_121681 LINC01182 Silent rs10005317 4 13887264 [T/C] NR_121681 LINC01182 Silent rs1397623 4 13887783 [T/C] NR_121681 LINC01182 Silent rs2058582 4 13892169 [A/G] NR_121681 LINC01182 Silent rs1553853 4 13894966 [T/G] NR_121681 LINC01182 Silent rs1606083 4 13897193 [A/G] NR_121681 LINC01182 Silent rs807780 4 13902266 [T/G] NR_121681 LINC01182 Silent rs16889408 4 13904166 [T/C] NR_121681 LINC01182 Silent rs16889409 4 13904303 [T/C] NR_121681 LINC01182 Silent rs807782 4 13905455 [A/C] NR_121681 LINC01182 Silent rs16889425 4 13905871 [T/C] NR_121681 LINC01182 Silent rs807783 4 13906669 [T/G] NR_121681 LINC01182 Silent rs4453935 4 13908785 [T/C] NR_121681 LINC01182 Silent rs11944826 4 13912034 [A/G] NR_121681 LINC01182 Silent rs953726 4 13912694 [A/G] NR_121681 LINC01182 Silent rs10805321 4 13914373 [A/C] NR_121681 LINC01182 Silent rs10939525 4 13914459 [T/C] NR_121681 LINC01182 Silent rs4698655 4 13915477 [T/C] NR_121681 LINC01182 Silent rs505703 4 13920982 [T/C] NR_121681 LINC01182 Silent rs13112792 4 13921238 [T/C] NR_121681 LINC01182 Silent rs527313 4 13922335 [A/G] NR_121681 LINC01182 Silent rs578319 4 13925186 [A/G] NR_121681 LINC01182 Silent rs579137 4 13928993 [A/G] NR_121681 LINC01182 Silent rs551592 4 13929751 [A/G] NR_121681 LINC01182 Silent rs11939384 4 13930615 [T/C] NR_121681 LINC01182 Silent rs10016970 4 13930991 [T/C] NR_121681 LINC01182 EXON Silent rs11940421 4 13931019 [T/C] NR_121681 LINC01182 EXON Silent rs564771 4 13932083 [A/G] NR_121681 LINC01182 EXON Silent rs552056 4 13936707 [T/C] rs7691637 4 13940961 [T/G] rs971079 4 13951077 [A/G] rs536993 4 13953276 [A/G] rs2120555 4 13953713 [A/G] rs11734382 4 13954615 [T/C] rs971048 4 13955163 [A/G] rs504227 4 13963977 [T/C] rs524675 4 13966851 [A/G] rs1444152 4 13975619 [T/C] rs541373 4 13977266 [T/G] rs535932 4 13988911 [A/C] rs10516270 4 13992268 [A/G] rs476133 4 13992929 [T/C] rs16889528 4 13992974 [A/G] rs489610 4 13996588 [A/G] rs576093 4 13996896 [A/G] rs10008925 4 14001392 [A/G] rs492134 4 14017269 [A/G] rs794095 4 14024946 [T/C] rs518592 4 14026281 [A/G] rs522578 4 14028747 [T/C] rs13121292 4 14033010 [A/G] rs4082824 4 14037453 [A/G] rs1877147 4 14037934 [A/G] rs4698240 4 14053263 [T/G] rs3857159 4 14056930 [T/C] rs7682816 4 14060248 [T/C] rs11736290 4 14062571 [A/G] rs4698241 4 14063649 [T/C] rs10516272 4 14064059 [A/G] rs9917971 4 14077835 [A/G] rs10028728 4 14082952 [A/G] rs4089881 4 14092353 [T/C] rs12499108 4 14098935 [T/C] rs4608810 4 14099183 [A/G] rs3915263 4 14099571 [A/G] rs3915267 4 14104524 [A/G] rs9291621 4 14110597 [T/C] rs11730712 4 14112550 [A/G] rs2204618 4 14112933 [A/G] rs3846395 4 14117046 [A/G] NR_033931 LINC01085 Silent rs17402733 4 14117252 [T/G] NR_033931 LINC01085 Silent rs17402971 4 14120589 [A/C] NR_033931 LINC01085 Silent rs3846396 4 14123352 [A/C] NR_033931 LINC01085 Silent rs4610328 4 14125088 [A/G] NR_033931 LINC01085 Silent rs3846401 4 14127483 [A/G] NR_033931 LINC01085 Silent rs17403552 4 14128820 [T/C] NR_033931 LINC01085 EXON Silent rs3846407 4 14131925 [T/G] NR_033931 LINC01085 Silent rs1834514 4 14135068 [A/C] NR_033931 LINC01085 Silent rs1426119 4 14135172 [A/C] NR_033931 LINC01085 Silent rs1426123 4 14137784 [A/C] NR_033931 LINC01085 Silent rs7670043 4 14138415 [T/C] NR_033931 LINC01085 Silent rs3893808 4 14139678 [A/G] NR_033931 LINC01085 Silent rs3846413 4 14140211 [T/C] NR_033931 LINC01085 EXON Silent rs16889750 4 14141243 [T/C] NR_033931 LINC01085 EXON Silent rs2912200 4 14143365 [T/C] rs17345360 4 14146572 [A/C] rs4698716 4 14148374 [T/C] rs34855554 4 14152469 [T/C] rs3846415 4 14152937 [T/C] rs11937314 4 14153819 [T/C] rs2114200 4 14155831 [A/G] rs10939534 4 14156515 [A/G] rs6818005 4 14157416 [T/G] rs17346022 4 14158633 [A/G] rs6830592 4 14158921 [T/C] rs3909661 4 14161125 [T/G] rs3111819 4 14163726 [A/G] rs10024326 4 14164082 [A/C] rs3111820 4 14164509 [A/G] rs3096592 4 14165975 [T/G] rs2903626 4 14167059 [T/C] rs12499480 4 14167488 [A/G] rs3111816 4 14179198 [A/G] rs3096590 4 14182464 [T/C] rs2004908 4 14183204 [A/G] rs6846915 4 14185184 [A/G] rs3096587 4 14188496 [A/G] rs11931459 4 14192133 [T/G] rs9998508 4 14193608 [A/G] rs12512931 4 14198023 [T/C] rs1549457 4 14198860 [T/C] rs890299 4 14204807 [T/G] rs11724569 4 14216574 [T/C] rs2969168 4 14217009 [A/G] rs16889857 4 14221055 [T/C] rs3111828 4 14222240 [T/G] rs3096566 4 14222539 [T/C] rs10516275 4 14222634 [T/C] rs10017183 4 14232056 [T/C] rs10939537 4 14234630 [T/C] rs1541757 4 14236012 [T/G] rs16889917 4 14245329 [T/C] rs10025267 4 14245558 [A/C] rs12502901 4 14245822 [A/G] rs10470841 4 14250959 [A/G] rs7691835 4 14255076 [T/G] rs12645353 4 14255866 [T/C] rs3096585 4 14257152 [A/G] rs3096584 4 14257631 [A/G] rs2052711 4 14259503 [A/G] rs3096581 4 14263549 [T/C] rs13108994 4 14267241 [T/C] rs3096579 4 14267496 [T/C] rs13148052 4 14268049 [T/C] rs890300 4 14269174 [T/C] rs17415839 4 14269562 [A/G] rs12499689 4 14270358 [T/C] rs16889949 4 14272582 [T/G] rs16889955 4 14273807 [A/G] rs3111813 4 14275327 [A/C] rs1991268 4 14277183 [T/C] rs1426110 4 14279189 [T/C] rs16890027 4 14280282 [A/G] rs6826155 4 14280826 [A/G] rs10013659 4 14282131 [A/G] rs16890060 4 14284343 [A/G] rs13131008 4 14287766 [A/G] rs1544874 4 14294745 [T/C] rs1426107 4 14296300 [T/C] rs2079949 4 14296613 [T/C] rs16890073 4 14302221 [T/C] rs2554377 4 14306031 [T/C] rs4698250 4 14312034 [T/C] rs2903643 4 14312197 [A/G] rs10488976 4 14312437 [T/C] rs16890128 4 14314002 [T/C] rs11733030 4 14314054 [T/C] rs6449012 4 14317116 [A/G] rs16890136 4 14317229 [T/C] rs758877 4 14320086 [A/C] rs4698728 4 14323343 [A/G] rs10805326 4 14324623 [A/G] rs4698729 4 14327348 [T/C] rs6827530 4 14330468 [A/G] rs17464021 4 14331472 [A/G] rs16890186 4 14335499 [T/C] rs4698732 4 14338342 [T/C] rs4140926 4 14340073 [T/C] rs10022773 4 14345605 [A/G] rs7660268 4 14349700 [A/C] rs9996349 4 14350981 [A/G] rs2109678 4 14355389 [T/C] rs10805327 4 14358260 [A/C] rs6835756 4 14358490 [A/G] rs10155152 4 14359888 [T/G] rs6814586 4 14361693 [T/C] rs6816401 4 14362571 [T/C] rs11932589 4 14365576 [A/G] rs758878 4 14367070 [T/C] rs4698737 4 14368628 [A/G] rs6449020 4 14369076 [T/C] rs16890321 4 14370747 [T/C] rs17466384 4 14373371 [A/C] rs6839912 4 14384751 [A/G] rs1860673 4 14385809 [T/C] rs10488980 4 14388846 [A/G] rs1013284 4 14389355 [A/G] rs16890379 4 14391806 [A/G] rs2191684 4 14392330 [T/C] rs17468022 4 14393864 [T/C] rs7654792 4 14394452 [T/C] rs6449024 4 14397827 [A/G] rs12331778 4 14400376 [A/G] rs2109673 4 14403377 [A/G] rs2109674 4 14420921 [A/G] rs218769 4 14428542 [T/G] rs16890431 4 14431387 [A/G] rs7693669 4 14433990 [A/G] rs218775 4 14437458 [T/G] rs6824715 4 14438997 [A/C] rs1875355 4 14442252 [A/G] rs6449031 4 14442433 [T/C] rs7700111 4 14443769 [T/C] rs16890501 4 14453452 [T/C] rs13117296 4 14454244 [T/C] rs1501159 4 14462605 [A/G] rs1909917 4 14472634 [T/G] NR_126435 LINC00504 EXON Silent rs1501163 4 14477164 [T/C] NR_126435 LINC00504 Silent rs13152405 4 14497339 [A/G] NR_126435 LINC00504 Silent rs13130965 4 14500927 [T/C] NR_126435 LINC00504 Silent rs10939557 4 14505552 [T/C] NR_126435 LINC00504 Silent rs16890598 4 14511712 [T/C] NR_126435 LINC00504 Silent rs16890604 4 14522601 [T/C] NR_126435 LINC00504 Silent rs17351936 4 14526801 [T/C] NR_126435 LINC00504 Silent rs1553278 4 14533433 [T/C] NR_126435 LINC00504 Silent rs905043 4 14539140 [T/G] NR_126435 LINC00504 Silent rs747978 4 14539436 [T/C] NR_126435 LINC00504 Silent rs11939104 4 14540251 [T/C] NR_126435 LINC00504 Silent rs10516279 4 14551585 [A/G] NR_126435 LINC00504 Silent rs1501180 4 14552520 [T/C] NR_126435 LINC00504 Silent rs16868209 4 14556388 [T/G] NR_126435 LINC00504 Silent rs6823611 4 14557065 [A/G] NR_126435 LINC00504 Silent rs1875358 4 14557480 [A/C] NR_126435 LINC00504 Silent rs16890645 4 14558941 [T/C] NR_126435 LINC00504 Silent rs16890647 4 14561973 [T/C] NR_126435 LINC00504 Silent rs12639674 4 14562019 [T/C] NR_126435 LINC00504 Silent rs1392908 4 14564502 [A/G] NR_126435 LINC00504 Silent rs16890684 4 14572063 [T/C] NR_126435 LINC00504 Silent rs10012584 4 14574597 [T/C] NR_126435 LINC00504 Silent rs10029194 4 14577711 [A/G] NR_126435 LINC00504 Silent rs16890724 4 14578377 [T/C] NR_126435 LINC00504 Silent rs16890738 4 14582702 [A/G] NR_126435 LINC00504 Silent rs7681043 4 14583787 [A/G] NR_126435 LINC00504 Silent rs6847363 4 14592876 [T/C] NR_126435 LINC00504 Silent rs1501154 4 14594724 [A/G] NR_126435 LINC00504 Silent rs1501157 4 14597832 [T/C] NR_126435 LINC00504 Silent rs1501158 4 14598431 [A/C] NR_126435 LINC00504 Silent rs1501170 4 14602461 [T/C] NR_126435 LINC00504 Silent rs17367774 4 14602568 [A/G] NR_126435 LINC00504 Silent rs17367859 4 14602883 [T/C] NR_126435 LINC00504 Silent rs6837615 4 14609901 [A/C] NR_126435 LINC00504 Silent rs12641168 4 14614441 [T/C] NR_126435 LINC00504 Silent rs9996860 4 14617465 [A/G] NR_126435 LINC00504 Silent rs6852076 4 14620966 [T/C] NR_126435 LINC00504 Silent rs10001818 4 14621620 [T/C] NR_126435 LINC00504 Silent rs16890883 4 14626431 [T/C] NR_126435 LINC00504 Silent rs10017988 4 14634108 [A/G] NR_126435 LINC00504 Silent rs17371992 4 14649304 [A/C] NR_126435 LINC00504 Silent rs4550921 4 14650646 [A/C] NR_126435 LINC00504 Silent rs4315781 4 14659007 [T/G] NR_126435 LINC00504 Silent rs764759 4 14660073 [T/C] NR_126435 LINC00504 Silent rs956518 4 14660437 [A/G] NR_126435 LINC00504 Silent rs10001851 4 14671493 [T/C] NR_126435 LINC00504 Silent rs4698079 4 14673461 [A/G] NR_126435 LINC00504 Silent rs10805335 4 14675728 [T/C] NR_126435 LINC00504 Silent rs3891377 4 14678186 [A/C] NR_126435 LINC00504 Silent rs7679234 4 14689222 [T/C] NR_126435 LINC00504 Silent rs6856233 4 14691708 [T/C] NR_126435 LINC00504 Silent rs11932201 4 14695432 [T/G] NR_126435 LINC00504 Silent rs4698281 4 14699227 [T/C] NR_126435 LINC00504 Silent rs4327484 4 14700515 [T/C] NR_126435 LINC00504 Silent rs4293781 4 14706991 [T/C] NR_126435 LINC00504 Silent rs4515159 4 14727209 [T/C] NR_126435 LINC00504 Silent rs10016726 4 14733772 [A/G] NR_126435 LINC00504 Silent rs6814769 4 14741456 [T/G] NR_126435 LINC00504 Silent rs11735459 4 14743209 [T/G] NR_126435 LINC00504 Silent rs4464561 4 14744996 [T/C] NR_126435 LINC00504 Silent rs11724609 4 14745825 [T/C] NR_126435 LINC00504 Silent rs4577572 4 14751518 [T/C] NR_126435 LINC00504 Silent rs7670366 4 14752727 [A/G] NR_126435 LINC00504 Silent rs6846158 4 14764460 [A/G] NR_126435 LINC00504 Silent rs7670595 4 14765943 [T/C] NR_126435 LINC00504 Silent rs4568238 4 14769762 [A/C] NR_126435 LINC00504 Silent rs4364258 4 14771119 [T/C] NR_126435 LINC00504 Silent rs4342182 4 14771349 [T/G] NR_126435 LINC00504 Silent rs10007197 4 14773458 [A/C] NR_126435 LINC00504 Silent rs6829622 4 14783158 [T/C] NR_126435 LINC00504 Silent rs6812089 4 14783489 [T/G] NR_126435 LINC00504 Silent rs12502866 4 14790478 [A/G] NR_126435 LINC00504 Silent rs4298137 4 14803794 [T/C] NR_126435 LINC00504 Silent rs13121851 4 14804417 [A/G] NR_126435 LINC00504 Silent rs11723660 4 14805560 [T/C] NR_126435 LINC00504 Silent rs10011351 4 14806347 [A/G] NR_126435 LINC00504 Silent rs11944252 4 14810259 [T/G] NR_126435 LINC00504 Silent rs11731529 4 14811750 [T/C] NR_126435 LINC00504 Silent rs13145996 4 14811962 [T/C] NR_126435 LINC00504 Silent rs6853723 4 14812561 [T/C] NR_126435 LINC00504 Silent rs4698295 4 14812935 [T/C] NR_126435 LINC00504 Silent rs7658940 4 14818982 [T/C] NR_126435 LINC00504 Silent rs4569748 4 14832006 [A/G] NR_126435 LINC00504 Silent rs10939594 4 14837288 [A/C] NR_126435 LINC00504 Silent rs7695275 4 14840148 [T/C] NR_126435 LINC00504 Silent rs4235370 4 14844405 [A/G] NR_126435 LINC00504 Silent rs1826705 4 14853337 [T/C] NR_126435 LINC00504 Silent rs1316686 4 14853491 [A/G] NR_126435 LINC00504 Silent rs16891104 4 14860842 [T/C] NR_126435 LINC00504 Silent rs16891108 4 14862873 [T/C] NR_126435 LINC00504 Silent rs4698299 4 14863713 [T/C] NR_126435 LINC00504 Silent rs6848922 4 14864422 [T/C] NR_126435 LINC00504 Silent rs6850085 4 14866685 [A/C] NR_126435 LINC00504 Silent rs28597787 4 14871034 [A/G] NR_126435 LINC00504 Silent rs11726071 4 14872639 [T/C] NR_126435 LINC00504 Silent rs923983 4 14874104 [T/C] NR_126435 LINC00504 Silent rs12646676 4 14874657 [A/G] NR_126435 LINC00504 Silent rs13138689 4 14874745 [A/G] NR_126435 LINC00504 Silent rs6858687 4 14876427 [T/C] NR_126435 LINC00504 Silent rs6848585 4 14879196 [T/C] NR_126435 LINC00504 Silent rs17440311 4 14885375 [A/C] NR_126435 LINC00504 Silent rs9990522 4 14886330 [A/G] NR_126435 LINC00504 Silent rs9884305 4 14888787 [A/G] NR_126435 LINC00504 Silent rs1494951 4 14892595 [A/G] rs16891135 4 14895945 [A/G] rs16891148 4 14902808 [T/C] rs750703 4 14903605 [A/C] rs11931562 4 14904847 [T/C] rs6815830 4 14906935 [T/C] rs7680772 4 14911059 [A/G] rs10213507 4 14911772 [A/C] NR_038857 CPEB2-DT EXON Silent rs1994945 4 14918627 [A/G] NR_038857 CPEB2-DT Silent rs16891172 4 14918840 [T/G] NR_038857 CPEB2-DT Silent rs13119988 4 14921247 [T/C] NR_038857 CPEB2-DT Silent rs6449092 4 14926053 [T/C] NR_038857 CPEB2-DT Silent rs6857060 4 14926218 [A/G] NR_038857 CPEB2-DT Silent rs12646389 4 14927008 [T/C] NR_038857 CPEB2-DT Silent rs12640213 4 14927179 [A/G] NR_038857 CPEB2-DT Silent rs12498517 4 14929433 [T/C] NR_038857 CPEB2-DT Silent rs7656729 4 14929874 [A/G] NR_038857 CPEB2-DT Silent rs10031277 4 14931835 [T/C] NR_038857 CPEB2-DT Silent rs11722368 4 14934107 [T/C] NR_038857 CPEB2-DT Silent rs7685796 4 14944898 [A/G] NR_038857 CPEB2-DT Silent rs1494957 4 14948831 [T/C] NR_038857 CPEB2-DT Silent rs2132082 4 14955398 [T/C] NR_038857 CPEB2-DT Silent rs6449093 4 14962496 [A/G] NR_038857 CPEB2-DT Silent rs1494948 4 14972561 [T/C] NR_038857 CPEB2-DT Silent rs11941349 4 14973588 [T/C] NR_038857 CPEB2-DT Silent rs7661252 4 14981989 [T/C] NR_038857 CPEB2-DT Silent rs7673375 4 14984117 [T/G] NR_038857 CPEB2-DT Silent rs13117049 4 14990889 [T/G] NR_038857 CPEB2-DT Silent rs13140166 4 15028262 [A/G] NM_001177384,NM_001177383,NM_182646,NM_001177381,NM_182485,NM_001177382,NR_125911 CPEB2,CPEB2,CPEB2,CPEB2,CPEB2,CPEB2,LOC101929095 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4453931 4 15031397 [A/G] NM_001177384,NM_001177383,NM_182646,NM_001177381,NM_182485,NM_001177382,NR_125911 CPEB2,CPEB2,CPEB2,CPEB2,CPEB2,CPEB2,LOC101929095 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11946242 4 15032569 [T/C] NM_001177384,NM_001177383,NM_182646,NM_001177381,NM_182485,NM_001177382,NR_125911 CPEB2,CPEB2,CPEB2,CPEB2,CPEB2,CPEB2,LOC101929095 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2604573 4 15038411 [T/C] NM_001177384,NM_001177383,NM_182646,NM_001177381,NM_182485,NM_001177382,NR_125911 CPEB2,CPEB2,CPEB2,CPEB2,CPEB2,CPEB2,LOC101929095 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2604578 4 15045896 [A/G] NM_001177384,NM_001177383,NM_182646,NM_001177381,NM_182485,NM_001177382,NR_125911 CPEB2,CPEB2,CPEB2,CPEB2,CPEB2,CPEB2,LOC101929095 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17450086 4 15051670 [A/G] NM_001177384,NM_001177383,NM_182646,NM_001177381,NM_182485,NM_001177382,NR_125911 CPEB2,CPEB2,CPEB2,CPEB2,CPEB2,CPEB2,LOC101929095 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3749570 4 15067580 [T/G] NM_001177384,NM_001177383,NM_182646,NM_001177381,NM_182485,NM_001177382,NR_125911 CPEB2,CPEB2,CPEB2,CPEB2,CPEB2,CPEB2,LOC101929095 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17385126 4 15075423 [T/G] NR_125911 LOC101929095 Silent rs2604536 4 15079533 [T/C] NR_125911 LOC101929095 Silent rs2604547 4 15089689 [A/C] NR_125911 LOC101929095 Silent rs2604548 4 15090453 [T/C] NR_125911 LOC101929095 Silent rs7681288 4 15096523 [A/G] NR_125911 LOC101929095 Silent rs11729197 4 15101916 [A/G] NR_125911 LOC101929095 Silent rs1455208 4 15102887 [A/G] NR_125911 LOC101929095 Silent rs12646901 4 15102929 [T/C] NR_125911 LOC101929095 Silent rs12644133 4 15104421 [T/C] NR_125911 LOC101929095 Silent rs7687891 4 15104690 [T/C] NR_125911 LOC101929095 Silent rs2604558 4 15107677 [A/G] NR_125911 LOC101929095 Silent rs1378343 4 15112646 [T/G] NR_125911 LOC101929095 Silent rs2034797 4 15112737 [A/G] NR_125911 LOC101929095 Silent rs2034796 4 15112878 [A/G] NR_125911 LOC101929095 Silent rs1378342 4 15117192 [T/C] NR_125911 LOC101929095 Silent rs1378341 4 15118979 [T/C] NR_125911 LOC101929095 Silent rs2702546 4 15120374 [A/G] NR_125911 LOC101929095 Silent rs2702544 4 15120587 [A/G] NR_125911 LOC101929095 Silent rs11721627 4 15127630 [A/G] NR_125911 LOC101929095 Silent rs1455207 4 15128633 [A/G] NR_125911 LOC101929095 Silent rs16891402 4 15131114 [A/C] NR_125911 LOC101929095 Silent rs13136309 4 15134596 [T/C] NR_125911 LOC101929095 Silent rs17452586 4 15143489 [T/C] NR_125911 LOC101929095 Silent rs2604562 4 15145180 [A/C] NR_125911 LOC101929095 Silent rs13146533 4 15146875 [A/G] NR_125911 LOC101929095 Silent rs2702534 4 15147403 [T/C] NR_125911 LOC101929095 Silent rs16891473 4 15148917 [A/G] NR_125911 LOC101929095 Silent rs16891486 4 15149977 [A/C] NR_125911 LOC101929095 Silent rs930830 4 15151976 [T/C] NR_125911 LOC101929095 Silent rs1455202 4 15154795 [A/G] NR_125911 LOC101929095 Silent rs1817186 4 15167548 [A/G] NR_125911 LOC101929095 Silent rs3857144 4 15167726 [T/C] NR_125911 LOC101929095 Silent rs974179 4 15175036 [A/G] NR_125911 LOC101929095 Silent rs10155296 4 15175539 [A/G] NR_125911 LOC101929095 Silent rs10014445 4 15181885 [T/C] NR_125911 LOC101929095 Silent rs10021046 4 15184903 [T/C] NR_125911 LOC101929095 Silent rs10805344 4 15193122 [T/C] NR_125911 LOC101929095 Silent rs731978 4 15194513 [T/C] NR_125911 LOC101929095 Silent rs10008462 4 15197936 [A/G] NR_125911 LOC101929095 Silent rs10516285 4 15200699 [A/G] NR_125911 LOC101929095 Silent rs4309834 4 15204833 [T/C] NR_125911 LOC101929095 Silent rs10516284 4 15206338 [A/G] NR_125911 LOC101929095 Silent rs1869696 4 15210204 [A/C] NR_125911 LOC101929095 Silent rs16891600 4 15210390 [T/C] NR_125911 LOC101929095 Silent rs1869693 4 15213954 [A/G] NR_125911 LOC101929095 Silent rs4698323 4 15219683 [A/G] NR_125911 LOC101929095 Silent rs9991734 4 15219710 [T/C] NR_125911 LOC101929095 Silent rs6449117 4 15223639 [A/G] NR_125911 LOC101929095 Silent rs11737782 4 15227612 [A/G] NR_125911 LOC101929095 Silent rs12648362 4 15230534 [A/C] NR_125911 LOC101929095 Silent rs4074082 4 15233866 [T/C] NR_125911 LOC101929095 Silent rs6813890 4 15239767 [T/C] NR_125911 LOC101929095 Silent rs6811795 4 15243220 [A/C] NR_125911 LOC101929095 Silent rs10011591 4 15246897 [T/G] NR_125911 LOC101929095 Silent rs12646586 4 15252649 [T/C] NR_125911 LOC101929095 Silent rs13144510 4 15254268 [A/C] NR_125911 LOC101929095 Silent rs4698099 4 15254870 [T/G] NR_125911 LOC101929095 Silent rs13143217 4 15255882 [A/G] NR_125911 LOC101929095 Silent rs10016323 4 15258501 [A/C] NR_125911 LOC101929095 Silent rs12641060 4 15258995 [T/G] NR_125911 LOC101929095 Silent rs4403047 4 15259423 [A/G] NR_125911 LOC101929095 Silent rs6845088 4 15262507 [T/C] NR_125911 LOC101929095 Silent rs35315148 4 15295105 [T/C] NR_125911 LOC101929095 Silent rs16891689 4 15315490 [A/C] NR_125911 LOC101929095 Silent rs4235375 4 15327663 [A/G] NR_125911 LOC101929095 Silent rs16891741 4 15336287 [T/G] NR_125911 LOC101929095 Silent rs4235376 4 15339942 [T/C] NR_125911 LOC101929095 Silent rs10027563 4 15340971 [A/G] NR_125911 LOC101929095 Silent rs10033552 4 15342608 [T/C] NR_125911,NM_001135170 LOC101929095,C1QTNF7 Silent,Silent rs13139715 4 15353889 [A/G] NR_125911,NM_001135170 LOC101929095,C1QTNF7 Silent,Silent rs16891785 4 15369280 [A/C] NR_125911,NM_001135170 LOC101929095,C1QTNF7 Silent,Silent rs4303974 4 15375984 [A/C] NR_125911,NM_001135170 LOC101929095,C1QTNF7 Silent,Silent rs4698103 4 15379272 [A/C] NR_125911,NM_001135170,NM_001135171 LOC101929095,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs6449134 4 15380517 [T/G] NR_125911,NM_001135170,NM_001135171 LOC101929095,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs16891829 4 15380910 [T/C] NR_125911,NM_001135170,NM_001135171 LOC101929095,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs16891831 4 15381392 [A/G] NR_125911,NM_001135170,NM_001135171 LOC101929095,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs765747 4 15393560 [T/C] NR_125911,NM_001135170,NM_001135171 LOC101929095,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs2252240 4 15395029 [A/G] NR_125911,NM_001135170,NM_001135171 LOC101929095,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs1861046 4 15397906 [A/G] NR_125911,NM_001135170,NM_001135171 LOC101929095,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs6449138 4 15409103 [A/G] NR_125911,NM_001135170,NM_001135171 LOC101929095,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs2192355 4 15420679 [T/C] NR_125911,NM_001135170,NM_001135171 LOC101929095,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs2192356 4 15424591 [A/G] NR_125911,NM_001135170,NM_001135171 LOC101929095,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs10003299 4 15425531 [A/G] NR_125911,NM_001135170,NM_001135171 LOC101929095,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs9998753 4 15426468 [T/C] NR_125911,NM_001135170,NM_001135171 LOC101929095,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs13116208 4 15430626 [T/G] NM_001135170,NM_001135171,NM_031911 C1QTNF7,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs1029973 4 15438851 [T/C] NM_001135170,NM_001135171,NM_031911 C1QTNF7,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs17469634 4 15441980 [A/G] NM_001135170,NM_001135171,NM_031911 C1QTNF7,C1QTNF7,C1QTNF7 Silent,Silent,Silent rs10022438 4 15444886 [A/G] NM_001135170,NM_001135171,NM_031911 C1QTNF7,C1QTNF7,C1QTNF7 EXON Silent,Silent,Silent rs768032 4 15445072 [A/G] NM_001135170,NM_001135171,NM_031911 C1QTNF7,C1QTNF7,C1QTNF7 EXON Silent,Silent,Silent rs2314590 4 15445533 [T/C] NM_001135170,NM_001135171,NM_031911 C1QTNF7,C1QTNF7,C1QTNF7 EXON Silent,Silent,Silent rs2160046 4 15453870 [T/C] rs2192362 4 15456446 [T/C] rs16891991 4 15456666 [A/G] rs722235 4 15460334 [T/C] rs13123050 4 15460758 [A/C] rs719993 4 15467035 [A/G] rs11728800 4 15474996 [T/C] NM_020785,NM_001164720,NM_001080522 CC2D2A,CC2D2A,CC2D2A Silent,Silent,Silent rs9993580 4 15480225 [A/C] NM_020785,NM_001164720,NM_001080522 CC2D2A,CC2D2A,CC2D2A Silent,Silent,Silent rs1861049 4 15482322 [T/C] NM_020785,NM_001164720,NM_001080522 CC2D2A,CC2D2A,CC2D2A Silent,Silent,Silent rs1861050 4 15482360 [T/C] NM_020785,NM_001164720,NM_001080522 CC2D2A,CC2D2A,CC2D2A EXON Nonsense_R88X,Synonymous_S52S,Synonymous_S52S rs4698112 4 15487432 [A/G] NM_001080522 CC2D2A Silent rs4698390 4 15493755 [T/C] NM_001080522 CC2D2A Silent rs16892054 4 15496270 [A/G] NM_001080522 CC2D2A Silent rs6811203 4 15496310 [T/C] NM_001080522 CC2D2A Silent rs2160043 4 15499251 [T/C] NM_001080522 CC2D2A Silent rs7682982 4 15501503 [A/G] NM_001080522 CC2D2A Silent rs1154578 4 15507032 [T/C] NM_001080522 CC2D2A Silent rs767092 4 15509291 [A/G] NM_001080522 CC2D2A Silent rs7686668 4 15515791 [T/C] NM_001080522 CC2D2A Silent rs2286976 4 15516389 [T/C] NM_001080522 CC2D2A EXON Synonymous_H259H rs16892095 4 15518357 [A/C] NM_001080522 CC2D2A EXON Missense_E376A rs16892107 4 15522209 [T/C] NM_001080522 CC2D2A Silent rs13131119 4 15522282 [T/C] NM_001080522 CC2D2A Silent rs7675761 4 15527808 [A/G] NM_001080522 CC2D2A Silent rs7687556 4 15535095 [A/G] NM_001080522 CC2D2A Silent rs16892131 4 15539202 [T/C] NM_001080522 CC2D2A Silent rs1861044 4 15539498 [A/G] NM_001080522 CC2D2A Silent rs6812708 4 15541609 [A/G] NM_001080522 CC2D2A Silent rs9918079 4 15545410 [A/G] NM_001080522 CC2D2A Silent rs12508186 4 15548415 [T/C] NM_001080522 CC2D2A Silent rs7697314 4 15548716 [A/C] NM_001080522 CC2D2A Silent rs16892141 4 15549778 [A/G] NM_001080522 CC2D2A Silent rs2041672 4 15552295 [A/G] NM_001080522 CC2D2A Silent rs13144428 4 15557442 [A/C] NM_001080522 CC2D2A Silent rs11932730 4 15565758 [T/C] NM_001080522 CC2D2A Silent rs13116304 4 15569146 [A/C] NM_001080522 CC2D2A Silent rs12649803 4 15577587 [A/G] NM_001080522 CC2D2A Silent rs12500587 4 15580754 [T/G] NM_001080522 CC2D2A Silent rs4267734 4 15586225 [A/G] NM_001080522 CC2D2A Silent rs11728037 4 15594898 [T/C] NM_001080522 CC2D2A Silent rs4270584 4 15600799 [A/G] NM_001080522 CC2D2A Silent rs10214 4 15606431 [T/C] NM_001193535,NM_001193534,NR_036464,NM_012161 FBXL5,FBXL5,FBXL5,FBXL5 EXON Silent,Silent,Silent,Silent rs10008376 4 15623955 [T/C] NM_001193535,NM_001193534,NR_036464,NM_012161 FBXL5,FBXL5,FBXL5,FBXL5 Silent,Silent,Silent,Silent rs10008975 4 15624571 [T/C] NM_001193535,NM_001193534,NR_036464,NM_012161 FBXL5,FBXL5,FBXL5,FBXL5 Silent,Silent,Silent,Silent rs7438356 4 15624770 [T/C] NM_001193535,NM_001193534,NR_036464,NM_012161 FBXL5,FBXL5,FBXL5,FBXL5 Silent,Silent,Silent,Silent rs6414764 4 15626475 [T/C] NM_001193535,NM_001193534,NR_036464,NM_012161 FBXL5,FBXL5,FBXL5,FBXL5 Silent,Silent,Silent,Silent rs6826058 4 15630737 [T/C] NM_001193535,NM_001193534,NR_036464,NM_012161 FBXL5,FBXL5,FBXL5,FBXL5 Silent,Silent,Silent,Silent rs6827406 4 15639171 [T/C] NM_001193535,NM_001193534,NR_036464,NM_012161 FBXL5,FBXL5,FBXL5,FBXL5 Silent,Silent,Silent,Silent rs13133213 4 15646794 [A/G] NM_001193535,NM_001193534,NR_036464,NM_012161 FBXL5,FBXL5,FBXL5,FBXL5 Silent,Silent,Silent,Silent rs10939630 4 15658481 [A/G] rs9994518 4 15659649 [T/C] rs12640192 4 15684234 [T/C] NM_001145191 FAM200B Silent rs6815254 4 15692058 [T/C] NM_001145191 FAM200B EXON Silent rs6449161 4 15692954 [T/C] rs4583752 4 15699005 [A/G] rs2302467 4 15705039 [T/G] NM_004334 BST1 Silent rs6840615 4 15707250 [A/G] NM_004334 BST1 EXON Missense_I101V rs2302465 4 15709192 [A/G] NM_004334 BST1 EXON Missense_R125H rs2302464 4 15709252 [A/G] NM_004334 BST1 EXON Missense_R145Q rs4541502 4 15712787 [T/G] NM_004334 BST1 Silent rs16892260 4 15713003 [T/G] NM_004334 BST1 Silent rs3213710 4 15717321 [A/G] NM_004334 BST1 Silent rs10001565 4 15722573 [T/C] NM_004334 BST1 Silent rs9942275 4 15723526 [A/G] NM_004334 BST1 Silent rs7688526 4 15724443 [T/G] NM_004334 BST1 Silent rs11931532 4 15725766 [T/C] NM_004334 BST1 Silent rs4588454 4 15728896 [A/G] NM_004334 BST1 Silent rs1058212 4 15733454 [A/C] NM_004334 BST1 EXON Synonymous_R315R rs4698412 4 15737348 [A/G] rs4538475 4 15737937 [A/G] rs11934811 4 15738253 [T/C] rs6835705 4 15738370 [A/G] rs4698119 4 15738795 [A/G] rs4698414 4 15738973 [A/G] rs997250 4 15739498 [A/G] rs3815466 4 15740292 [A/C] rs6833993 4 15741293 [A/G] rs1110258 4 15742716 [A/G] rs6852450 4 15742986 [T/C] rs4698415 4 15743391 [T/C] rs10019008 4 15743573 [T/C] rs11933202 4 15744528 [A/G] rs10020443 4 15748825 [T/C] rs6857601 4 15749167 [T/C] rs6837105 4 15753687 [A/G] rs868763 4 15755905 [T/C] rs12645519 4 15758931 [A/G] rs10002171 4 15767752 [T/C] rs11945730 4 15773008 [A/G] rs16892407 4 15773936 [A/G] rs6831585 4 15776181 [A/G] rs6449181 4 15779712 [T/C] rs7666953 4 15791464 [T/G] NR_132660,NM_001775 CD38,CD38 Silent,Silent rs16892418 4 15810779 [T/G] NR_132660,NM_001775 CD38,CD38 Silent,Silent rs6836946 4 15813607 [T/G] NR_132660,NM_001775 CD38,CD38 Silent,Silent rs7655635 4 15814621 [A/G] NR_132660,NM_001775 CD38,CD38 Silent,Silent rs6449195 4 15814814 [T/C] NR_132660,NM_001775 CD38,CD38 Silent,Silent rs3796868 4 15818391 [A/G] NR_132660,NM_001775 CD38,CD38 Silent,Silent rs3796867 4 15818548 [A/G] NR_132660,NM_001775 CD38,CD38 Silent,Silent rs3796866 4 15835365 [T/C] NR_132660,NM_001775 CD38,CD38 Silent,Silent rs1800051 4 15835844 [A/C] NR_132660,NM_001775 CD38,CD38 EXON Silent,Synonymous_I168I rs10805347 4 15840839 [A/G] NR_132660,NM_001775 CD38,CD38 Silent,Silent rs6813018 4 15849801 [T/C] NR_132660,NM_001775 CD38,CD38 Silent,Silent rs1803404 4 15850330 [T/G] NR_132660,NM_001775 CD38,CD38 EXON Silent,Silent rs1130169 4 15850685 [T/C] NR_132660,NM_001775 CD38,CD38 EXON Silent,Silent rs13137313 4 15851968 [A/G] NR_132660,NM_001775 CD38,CD38 EXON Silent,Silent rs17476066 4 15852104 [T/C] NR_132660,NM_001775 CD38,CD38 EXON Silent,Silent rs3733593 4 15854725 [A/G] NR_132660,NM_001775 CD38,CD38 EXON Silent,Silent rs13136270 4 15856799 [T/C] rs9998059 4 15866814 [T/C] rs2531166 4 15874104 [A/G] rs16892515 4 15879317 [A/G] rs2532083 4 15881412 [T/C] rs2532082 4 15881856 [T/G] rs758327 4 15883763 [A/G] rs2191003 4 15895791 [A/G] rs6845349 4 15896088 [A/C] rs727488 4 15896341 [T/C] rs11944611 4 15907133 [T/C] rs2532070 4 15910385 [A/G] rs2531149 4 15914006 [A/G] rs1966374 4 15914034 [A/G] rs12498177 4 15914801 [T/C] rs4698424 4 15915036 [A/C] rs11723486 4 15921471 [T/C] rs16892587 4 15922502 [A/G] rs876320 4 15930961 [A/G] rs11730943 4 15934405 [A/G] rs2532098 4 15934723 [T/G] rs12503130 4 15935268 [T/C] rs12503191 4 15935497 [T/C] rs2532095 4 15935760 [T/G] rs12499618 4 15936638 [T/C] rs2072313 4 15937731 [T/C] NM_005130 FGFBP1 EXON Synonymous_K175K rs16892645 4 15938392 [T/C] NM_005130 FGFBP1 Silent rs3822253 4 15942802 [T/G] rs1558198 4 15942832 [A/G] rs10939642 4 15943140 [A/G] rs16892663 4 15947267 [T/C] rs10939644 4 15947493 [T/C] rs9968434 4 15949531 [T/C] rs9968276 4 15949551 [A/G] rs12509859 4 15950731 [T/C] rs10755216 4 15957568 [T/C] rs4698429 4 15957763 [A/G] rs35584473 4 15960741 [T/C] rs4698431 4 15961555 [A/G] rs2286461 4 15963673 [A/G] NM_031950 FGFBP2 Silent rs2286460 4 15964040 [A/G] NM_031950 FGFBP2 Silent rs758329 4 15964485 [A/G] NM_031950 FGFBP2 EXON Missense_P90S rs1541458 4 15966840 [T/C] rs12506181 4 15967777 [T/C] rs11733056 4 15968139 [G/C] rs4698434 4 15968574 [T/C] rs2240688 4 15970349 [T/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3857147 4 15972549 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11735976 4 15972905 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7669462 4 15975839 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7690707 4 15979621 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6830263 4 15980454 [A/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11725522 4 15980975 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9685492 4 15981332 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12649852 4 15982480 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10428324 4 15983317 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7692432 4 15983335 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10428501 4 15983618 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2302167 4 15985802 [A/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1990271 4 15988239 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17477869 4 15991015 [A/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2240685 4 15991275 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2058147 4 15992486 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3796850 4 15994761 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17387100 4 15995125 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs717176 4 15995314 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6449211 4 15998470 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13141429 4 16003151 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6825026 4 16005061 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3796849 4 16005699 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2313734 4 16011211 [A/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13133332 4 16016690 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2531155 4 16018142 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17387327 4 16018244 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2677789 4 16018282 [T/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2286455 4 16020162 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 EXON Synonymous_A262A,Synonymous_A253A,Synonymous_A262A,Synonymous_A253A,Synonymous_A262A,Synonymous_A253A,Synonymous_A253A rs1517598 4 16020664 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2677791 4 16024136 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2240681 4 16024565 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1517599 4 16026458 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7663999 4 16026983 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs884718 4 16031448 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11729248 4 16033066 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1400771 4 16034634 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6816182 4 16035996 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2078622 4 16037352 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs950946 4 16038752 [T/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1400773 4 16038800 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6849988 4 16041487 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11733193 4 16046575 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12511202 4 16048413 [T/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16892888 4 16053179 [A/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6823548 4 16054926 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13137175 4 16057694 [T/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1554243 4 16063055 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10516295 4 16064027 [T/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13150823 4 16064648 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3857152 4 16067266 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16892920 4 16068748 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1040209 4 16072487 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs884227 4 16073092 [T/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs908645 4 16073221 [A/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10010994 4 16076784 [A/C] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10033189 4 16077515 [A/G] NM_001145850,NM_001145848,NM_001145849,NM_001145851,NM_006017,NM_001145847,NM_001145852 PROM1,PROM1,PROM1,PROM1,PROM1,PROM1,PROM1 EXON Synonymous_L5L,Synonymous_L5L,Synonymous_L5L,Synonymous_L5L,Synonymous_L5L,Synonymous_L5L,Synonymous_L5L rs7656857 4 16085850 [T/C] rs1004861 4 16087856 [T/G] rs11935542 4 16089854 [T/C] rs16892992 4 16091345 [T/G] rs2197253 4 16104115 [A/C] rs1115917 4 16104248 [A/G] rs16893029 4 16105431 [T/C] rs1554245 4 16107125 [T/C] rs1712493 4 16113889 [T/C] rs317881 4 16121755 [T/C] rs317892 4 16128075 [A/G] rs317898 4 16134120 [A/C] rs2120236 4 16134623 [T/C] rs317900 4 16135475 [T/C] rs317903 4 16138165 [T/C] rs11729630 4 16138797 [A/G] rs11730743 4 16145588 [A/G] rs12647911 4 16146149 [T/C] rs317866 4 16156273 [A/G] rs16893097 4 16156964 [T/G] rs10034143 4 16159734 [T/C] rs16893119 4 16161137 [A/G] rs13634 4 16163209 [T/C] NM_153365 TAPT1 EXON Silent rs9946 4 16163221 [T/C] NM_153365 TAPT1 EXON Silent rs10516299 4 16163486 [T/C] NM_153365 TAPT1 EXON Silent rs10516298 4 16164230 [T/C] NM_153365 TAPT1 EXON Silent rs7359 4 16164489 [A/G] NM_153365 TAPT1 EXON Silent rs16893137 4 16165070 [T/C] NM_153365 TAPT1 EXON Missense_N522S rs10516297 4 16166404 [T/C] NM_153365 TAPT1 Silent rs317874 4 16183180 [A/G] NM_153365 TAPT1 Silent rs16893162 4 16185525 [A/G] NM_153365 TAPT1 Silent rs10017532 4 16204829 [T/C] NM_153365 TAPT1 Silent rs28403341 4 16221118 [A/G] NM_153365 TAPT1 Silent rs10007592 4 16222046 [A/C] NM_153365 TAPT1 Silent rs35141398 4 16232330 [T/C] NR_027697,NR_027696 TAPT1-AS1,TAPT1-AS1 Silent,Silent rs203434 4 16234265 [A/G] NR_027697,NR_027696 TAPT1-AS1,TAPT1-AS1 Silent,Silent rs203438 4 16242215 [A/G] NR_027697,NR_027696 TAPT1-AS1,TAPT1-AS1 Silent,Silent rs203446 4 16255566 [A/C] NR_027697,NR_027696 TAPT1-AS1,TAPT1-AS1 Silent,Silent rs6822469 4 16257677 [T/C] NR_027697,NR_027696 TAPT1-AS1,TAPT1-AS1 Silent,Silent rs2215637 4 16258670 [T/C] NR_027697,NR_027696 TAPT1-AS1,TAPT1-AS1 EXON Silent,Silent rs11728731 4 16260060 [A/G] rs12502603 4 16261094 [A/G] rs17559158 4 16268263 [A/G] rs16893213 4 16272456 [A/G] rs6851785 4 16277491 [A/C] rs11721706 4 16281681 [A/G] rs6449223 4 16284487 [T/C] rs10489066 4 16292409 [A/G] rs2041540 4 16293543 [A/G] rs887649 4 16295798 [T/C] rs887648 4 16296121 [A/G] rs7660122 4 16304314 [A/G] rs10489065 4 16305979 [T/C] rs975777 4 16318066 [T/C] rs2191958 4 16334352 [T/C] rs2041538 4 16336013 [A/G] rs4395499 4 16346545 [A/C] rs17562392 4 16352116 [A/G] rs13131868 4 16353313 [A/G] rs4321631 4 16354757 [T/C] rs16893390 4 16362803 [T/C] rs16893392 4 16363818 [T/C] rs16893404 4 16365531 [A/G] rs11933865 4 16375164 [A/G] rs1005391 4 16386449 [A/G] rs17563866 4 16390191 [A/G] rs16893441 4 16390974 [T/C] rs6812305 4 16396682 [A/G] rs7662668 4 16397925 [A/G] rs1501139 4 16410294 [A/C] rs4698482 4 16410913 [T/G] rs7674517 4 16411704 [T/C] rs7657627 4 16412051 [T/C] rs10025710 4 16413099 [A/G] rs4698486 4 16418399 [T/C] rs7687486 4 16419601 [A/C] rs6449249 4 16419618 [A/G] rs2036361 4 16422288 [A/C] rs13147951 4 16427211 [A/G] rs2313547 4 16427592 [T/C] rs12503110 4 16428830 [T/C] rs1392898 4 16433770 [A/C] rs4698149 4 16447313 [A/G] rs16893497 4 16451719 [A/G] rs10020270 4 16460247 [A/G] rs7440228 4 16462094 [T/C] rs10026610 4 16462250 [A/G] rs884092 4 16468136 [T/G] rs9683798 4 16468648 [T/G] rs6830747 4 16469668 [A/G] rs6449254 4 16469713 [T/C] rs1120373 4 16476442 [T/C] rs905041 4 16478276 [A/G] rs6816070 4 16480357 [A/G] rs7672573 4 16481679 [T/C] rs1354079 4 16487781 [A/C] rs1501140 4 16491284 [A/G] rs1392896 4 16492812 [T/C] rs1501141 4 16494951 [T/C] rs16893547 4 16498825 [T/G] rs7698804 4 16499833 [A/G] rs7667171 4 16502568 [A/G] rs9993371 4 16510131 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs16893565 4 16511887 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs16893569 4 16511902 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs3792679 4 16512436 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs6824949 4 16513748 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs13126663 4 16518215 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs6843498 4 16521723 [T/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs12510434 4 16522293 [A/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs11732672 4 16524379 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs4698491 4 16526736 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs10020336 4 16527611 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs10019178 4 16530079 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs17488750 4 16530791 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs10805350 4 16531401 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs10805351 4 16531505 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs12498169 4 16531797 [T/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs13138387 4 16533376 [A/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs16893606 4 16537510 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs11947427 4 16540004 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs13110049 4 16546672 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs6819114 4 16546995 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs6855048 4 16549115 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs13133023 4 16550094 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs1501145 4 16551411 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs13113158 4 16551576 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs12233679 4 16551836 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs16893622 4 16553922 [T/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs1501127 4 16554662 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs2055418 4 16557143 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs12508513 4 16565404 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs11725152 4 16572822 [T/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs1392895 4 16575046 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs4698494 4 16578179 [A/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs13120039 4 16581810 [A/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs3935821 4 16585618 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs4072813 4 16585917 [A/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs13109710 4 16586122 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs7669580 4 16587201 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs10755217 4 16588729 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs11945652 4 16590588 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs2135442 4 16591598 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs6812263 4 16592117 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs10017860 4 16594879 [A/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs2173074 4 16598510 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs1496747 4 16599234 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs6818414 4 16600664 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs11931315 4 16601009 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs924156 4 16604093 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs16893678 4 16604857 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs17490415 4 16605178 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs13118746 4 16608497 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs16893682 4 16609801 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs33948812 4 16610295 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs1496750 4 16624209 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs17425382 4 16637714 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs12506426 4 16637779 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs924158 4 16638507 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs7693848 4 16638981 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs1972463 4 16641382 [G/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs4698502 4 16642464 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs12642363 4 16646025 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs10023986 4 16646358 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs3763967 4 16647943 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs3763969 4 16648246 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs1566066 4 16650090 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs13110156 4 16656578 [C/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs9996576 4 16656682 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs1027784 4 16666332 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs6449262 4 16668043 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs10939683 4 16671394 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs6851110 4 16674801 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs17492017 4 16677019 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs7660353 4 16677182 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs10027272 4 16677557 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs6848653 4 16680651 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs7661729 4 16680736 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs1395291 4 16681217 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs7692454 4 16681543 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs16893782 4 16686361 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs16893797 4 16694863 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs13110423 4 16694900 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs283029 4 16698184 [A/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs11930466 4 16705698 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs157619 4 16713075 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs17428815 4 16719156 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs1514644 4 16723640 [A/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs16893890 4 16726650 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs533825 4 16736065 [T/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs283019 4 16739648 [T/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs283018 4 16740168 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs883086 4 16744084 [T/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs1546182 4 16747687 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834 LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent rs157630 4 16753012 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs283027 4 16753863 [A/C] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs513488 4 16767708 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs207685 4 16773323 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs157613 4 16778287 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs207699 4 16786351 [A/C] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs207701 4 16786858 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs17757703 4 16789915 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs10489106 4 16794008 [T/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs158278 4 16801041 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs189987 4 16822918 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs123043 4 16823900 [A/C] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs207703 4 16828794 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs207710 4 16834640 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs629782 4 16837966 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs158260 4 16839420 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs12503223 4 16842716 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs2108935 4 16843910 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs207713 4 16851024 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs13135819 4 16855730 [T/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs6839117 4 16856564 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs6829935 4 16861512 [T/C] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs13113385 4 16865939 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs11734663 4 16867757 [T/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs13104451 4 16871315 [T/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs10939693 4 16873743 [A/C] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs16894138 4 16877760 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs10014964 4 16888776 [T/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs1483009 4 16892585 [A/C] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs1483012 4 16893893 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs7690911 4 16899946 [A/G] NM_001304434,NM_001304435,NM_001290,NM_001130834,NR_130734 LDB2,LDB2,LDB2,LDB2,LDB2 Silent,Silent,Silent,Silent,Silent rs992704 4 16906388 [A/G] rs6816423 4 16913766 [T/C] rs13126845 4 16914239 [A/G] rs2108937 4 16914874 [A/G] rs13129387 4 16915245 [T/C] rs4698165 4 16922182 [T/C] rs16894172 4 16927427 [A/C] rs725858 4 16929643 [A/G] rs2872565 4 16932945 [T/C] rs917494 4 16935552 [T/C] rs16894200 4 16940151 [T/C] rs1949292 4 16942990 [A/C] rs1514996 4 16960123 [T/C] rs6414774 4 16985245 [T/C] rs4698527 4 16992028 [T/C] rs16894222 4 16992876 [A/G] rs13109226 4 16995023 [T/C] rs4698529 4 16995752 [T/G] rs2314597 4 16997327 [T/C] rs6858060 4 17016263 [A/G] rs2102702 4 17025691 [A/C] rs9291651 4 17031095 [A/G] rs11730753 4 17035562 [T/C] rs6449275 4 17036244 [T/C] rs13109476 4 17039677 [A/G] rs11724970 4 17041687 [T/G] rs1514989 4 17042063 [T/C] rs13353571 4 17043787 [A/G] rs16894247 4 17044466 [T/C] rs13107569 4 17044760 [A/G] rs4426772 4 17045368 [A/G] rs16894256 4 17047470 [A/G] rs1356028 4 17047686 [A/G] rs10001817 4 17050660 [A/G] rs11929846 4 17051156 [T/C] rs16894263 4 17054262 [A/G] rs13143173 4 17054716 [T/C] rs828164 4 17060545 [A/G] rs828154 4 17062952 [A/G] rs828152 4 17063564 [T/C] rs828151 4 17063786 [A/C] rs16894291 4 17064024 [T/C] rs4698166 4 17067513 [A/G] rs1464091 4 17070502 [A/G] rs4698167 4 17082907 [T/C] rs1464483 4 17083204 [A/C] rs16894314 4 17091852 [T/C] rs16894315 4 17092275 [A/G] rs12647067 4 17095691 [T/C] rs13121153 4 17104059 [T/C] rs2056394 4 17105434 [T/C] rs2056393 4 17106331 [T/C] rs12640561 4 17112493 [T/C] rs10000500 4 17115201 [T/G] rs1522077 4 17115730 [A/G] rs675984 4 17123821 [A/G] rs9291654 4 17126696 [T/C] rs556904 4 17128572 [T/C] rs12645194 4 17133221 [T/C] rs9291655 4 17133297 [T/C] rs976717 4 17133741 [T/C] rs6845162 4 17136673 [T/C] rs970428 4 17136795 [A/C] rs629542 4 17137284 [A/C] rs10489116 4 17145268 [A/C] rs492959 4 17145515 [T/C] rs596777 4 17147731 [A/G] rs16894476 4 17148643 [T/C] rs627206 4 17149944 [A/G] rs504670 4 17156183 [T/C] rs667932 4 17165360 [A/G] rs566672 4 17167808 [T/C] rs16894543 4 17168001 [A/G] rs16868330 4 17168826 [A/G] rs659673 4 17178017 [T/G] NR_125919 LINC02493 EXON Silent rs1522075 4 17178058 [T/G] NR_125919 LINC02493 EXON Silent rs608897 4 17181579 [A/G] NR_125919 LINC02493 Silent rs574427 4 17187440 [A/G] NR_125919 LINC02493 Silent rs7669359 4 17188778 [T/C] rs7667911 4 17188787 [A/G] rs6449278 4 17194641 [A/G] rs721166 4 17196209 [T/G] rs13142734 4 17200948 [A/G] rs567404 4 17201248 [T/G] rs16894648 4 17205620 [T/C] rs6837748 4 17210786 [T/C] rs965572 4 17223625 [A/G] rs501015 4 17224160 [T/C] rs10025799 4 17224345 [A/G] rs509994 4 17228017 [T/C] rs662759 4 17230374 [A/G] rs9995238 4 17240787 [A/G] rs1402949 4 17242936 [A/G] rs16894737 4 17248161 [T/C] rs584272 4 17255650 [T/C] rs16894739 4 17256096 [T/C] rs613801 4 17257605 [A/G] rs144246 4 17259908 [A/G] rs673248 4 17261697 [A/G] rs531934 4 17268118 [T/G] rs12509299 4 17268148 [T/C] rs649405 4 17269405 [T/G] rs7356497 4 17272182 [A/G] rs12498656 4 17273603 [A/C] rs4585300 4 17275696 [T/C] rs12507442 4 17276304 [T/C] rs1981693 4 17279997 [A/G] rs6847269 4 17280522 [A/G] rs13149912 4 17289544 [T/C] rs10939711 4 17290784 [T/C] rs7663121 4 17291007 [T/C] rs4698560 4 17291396 [T/C] rs7694269 4 17293238 [T/C] rs6810740 4 17294785 [T/C] rs7690593 4 17298007 [A/G] rs7692897 4 17298445 [T/C] rs16894806 4 17301096 [A/G] rs16894824 4 17309906 [T/C] rs6843133 4 17318278 [A/G] rs7674435 4 17320155 [A/C] rs730308 4 17321714 [A/G] rs16894867 4 17325805 [T/C] rs10014616 4 17327791 [T/C] rs2872795 4 17330381 [T/C] rs13107521 4 17330760 [T/C] rs6823069 4 17331894 [T/G] rs16894897 4 17335027 [A/G] rs10939712 4 17336798 [A/G] rs10003191 4 17336925 [A/G] rs10222726 4 17342562 [T/C] rs16894917 4 17344492 [T/C] rs10000081 4 17348363 [T/C] rs13130097 4 17349030 [T/C] rs7665055 4 17359454 [T/C] rs16894953 4 17361114 [A/C] rs2314958 4 17361909 [A/G] rs6449287 4 17373412 [T/C] rs1901168 4 17379583 [T/C] rs4698581 4 17381717 [A/G] rs2122574 4 17385551 [T/C] rs6815737 4 17390785 [T/C] rs1868737 4 17401363 [T/C] rs10516312 4 17402150 [A/G] rs10012313 4 17405513 [A/G] rs1528604 4 17408416 [T/G] rs6856880 4 17419691 [T/G] rs10010240 4 17423823 [T/G] rs2697707 4 17427573 [A/G] rs7681641 4 17431869 [A/C] rs2697711 4 17431921 [A/G] rs7682455 4 17432275 [T/C] rs2697684 4 17435958 [T/C] rs7671329 4 17439346 [A/G] rs2518652 4 17448903 [A/G] rs2697695 4 17449199 [T/C] rs1852748 4 17450023 [T/C] rs6855040 4 17451760 [T/C] rs2597810 4 17453405 [T/C] rs2053882 4 17465704 [A/G] rs2518641 4 17467715 [T/C] rs13112606 4 17468047 [A/G] rs5005545 4 17469695 [A/G] rs10003746 4 17469817 [T/C] rs10007905 4 17471978 [A/G] rs2597751 4 17475541 [A/G] rs2518630 4 17477331 [A/G] rs4698599 4 17478268 [A/G] rs13128422 4 17479402 [T/C] rs1868733 4 17482912 [T/C] rs13138275 4 17483682 [A/G] rs2597754 4 17484602 [T/G] rs2597756 4 17485081 [T/C] rs1031326 4 17488064 [T/C] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR EXON Silent,Silent,Silent rs699459 4 17488072 [T/C] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR EXON Silent,Silent,Silent rs10604 4 17488132 [A/G] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR EXON Silent,Silent,Silent rs699460 4 17488286 [T/G] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR EXON Silent,Silent,Silent rs1049601 4 17488346 [A/G] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR EXON Silent,Silent,Silent rs1049600 4 17488351 [T/C] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR EXON Silent,Silent,Silent rs1049581 4 17488534 [A/G] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR EXON Silent,Silent,Silent rs744730 4 17491913 [T/C] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR Silent,Silent,Silent rs7660043 4 17492562 [A/G] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR Silent,Silent,Silent rs744731 4 17492843 [T/C] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR Silent,Silent,Silent rs12512471 4 17494643 [T/G] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR Silent,Silent,Silent rs11722315 4 17500905 [A/C] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR Silent,Silent,Silent rs2597775 4 17503382 [T/C] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR EXON Silent,Synonymous_L101L,Synonymous_L132L rs3733570 4 17503433 [T/C] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR EXON Silent,Synonymous_S84S,Synonymous_S115S rs17458406 4 17510236 [T/C] NR_156494,NM_001306140,NM_000320 QDPR,QDPR,QDPR Silent,Silent,Silent rs2597783 4 17516691 [T/C] rs7661303 4 17518920 [T/C] NM_001079827 CLRN2 Silent rs4698603 4 17519867 [A/G] NM_001079827 CLRN2 Silent rs10020773 4 17526682 [A/C] NM_001079827 CLRN2 Silent rs2597791 4 17528463 [A/G] NM_001079827 CLRN2 EXON Missense_A153T rs2535228 4 17532780 [A/G] rs1609899 4 17533530 [T/G] rs2518649 4 17537159 [T/G] rs1115896 4 17539754 [A/C] rs6843189 4 17546381 [T/C] rs2109520 4 17550349 [T/C] rs6828925 4 17561139 [A/G] rs3796812 4 17582051 [A/G] NM_015907 LAP3 Silent rs3733576 4 17586703 [T/C] NM_015907 LAP3 EXON Synonymous_A216A rs16895253 4 17586773 [A/G] NM_015907 LAP3 Silent rs11942938 4 17586841 [T/G] NM_015907 LAP3 Silent rs10005380 4 17593113 [T/G] NM_015907 LAP3 Silent rs6812675 4 17597549 [A/G] NM_015907 LAP3 Silent rs4698628 4 17608620 [A/G] NM_015907 LAP3 Silent rs4642241 4 17617111 [T/C] NM_025205 MED28 Silent rs1006722 4 17618713 [A/G] NM_025205 MED28 Silent rs555 4 17625658 [A/G] NM_025205 MED28 EXON Silent rs9884404 4 17625791 [T/C] NM_025205 MED28 EXON Silent rs2315552 4 17627294 [A/G] rs16895350 4 17633227 [A/G] rs6825562 4 17634213 [A/G] NM_015688 FAM184B EXON Missense_V1042A rs16895365 4 17636666 [T/C] NM_015688 FAM184B EXON Missense_N952S rs2286771 4 17643848 [A/G] NM_015688 FAM184B EXON Missense_R784W rs1558377 4 17650758 [A/G] NM_015688 FAM184B Silent rs10805358 4 17652450 [A/C] NM_015688 FAM184B Silent rs1860596 4 17660082 [T/C] NM_015688 FAM184B EXON Missense_R643H rs11934968 4 17667766 [A/G] NM_015688 FAM184B Silent rs10002848 4 17671195 [A/G] NM_015688 FAM184B Silent rs1558379 4 17672884 [T/C] NM_015688 FAM184B Silent rs10009541 4 17682218 [T/C] NM_015688 FAM184B Silent rs1008375 4 17682834 [T/C] NM_015688 FAM184B Silent rs11722037 4 17683811 [A/G] NM_015688 FAM184B Silent rs10939746 4 17684951 [A/G] NM_015688 FAM184B Silent rs11947857 4 17691047 [T/C] NM_015688 FAM184B Silent rs4698649 4 17692782 [A/G] NM_015688 FAM184B Silent rs3733580 4 17695073 [A/G] NM_015688 FAM184B Silent rs6825100 4 17696434 [A/G] NM_015688 FAM184B Silent rs6855046 4 17702765 [T/C] NM_015688 FAM184B Silent rs11735608 4 17713717 [T/G] NM_015688 FAM184B Silent rs4631043 4 17727941 [A/G] NM_015688 FAM184B Silent rs13148666 4 17728356 [T/C] NM_015688 FAM184B Silent rs16895598 4 17740791 [T/C] NM_015688 FAM184B Silent rs11947586 4 17746188 [T/C] NM_015688 FAM184B Silent rs6844932 4 17747023 [T/C] NM_015688 FAM184B Silent rs16868358 4 17762306 [T/C] NM_015688 FAM184B Silent rs11730953 4 17765622 [T/C] NM_015688 FAM184B Silent rs17583557 4 17769238 [A/G] NM_015688 FAM184B Silent rs7682632 4 17780932 [A/G] NM_015688 FAM184B Silent rs16895707 4 17781209 [T/C] NM_015688 FAM184B Silent rs740672 4 17782264 [T/C] NM_015688 FAM184B Silent rs16895737 4 17789420 [A/C] rs7672919 4 17797455 [T/G] NR_144303,NR_144305,NR_144301,NR_144310 DCAF16,DCAF16,DCAF16,DCAF16 Silent,Silent,Silent,Silent rs7678436 4 17797966 [A/G] NR_144303,NR_144305,NR_144301,NR_144310 DCAF16,DCAF16,DCAF16,DCAF16 Silent,Silent,Silent,Silent rs2286540 4 17809538 [A/G] NR_144303,NR_144305,NR_144301,NR_144310,NM_001345885,NM_001345880,NM_001345884,NM_001345882,NM_017741,NM_001345881 DCAF16,DCAF16,DCAF16,DCAF16,DCAF16,DCAF16,DCAF16,DCAF16,DCAF16,DCAF16 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7667864 4 17811914 [A/C] NR_144303,NR_144305,NR_144301,NR_144310,NM_001345885,NM_001345880,NM_001345884,NM_001345882,NM_017741,NM_001345881 DCAF16,DCAF16,DCAF16,DCAF16,DCAF16,DCAF16,DCAF16,DCAF16,DCAF16,DCAF16 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11941723 4 17812528 [A/G] NM_022346,NR_073124 NCAPG,NCAPG EXON Silent,Silent rs2074974 4 17812615 [A/C] NM_022346,NR_073124 NCAPG,NCAPG EXON Silent,Silent rs1395371 4 17813711 [T/C] NM_022346,NR_073124 NCAPG,NCAPG Silent,Silent rs2302212 4 17818885 [T/C] NM_022346,NR_073124 NCAPG,NCAPG EXON Synonymous_D259D,Silent rs11933789 4 17825159 [T/C] NM_022346,NR_073124 NCAPG,NCAPG Silent,Silent rs16895825 4 17826256 [A/G] NM_022346,NR_073124 NCAPG,NCAPG Silent,Silent rs16895868 4 17842342 [T/C] NM_022346,NR_073124 NCAPG,NCAPG Silent,Silent rs17585261 4 17844029 [A/G] NM_022346,NR_073124,NR_136669,NM_153686 NCAPG,NCAPG,LCORL,LCORL EXON Silent,Silent,Silent,Silent rs16895877 4 17846522 [T/C] NR_136669,NM_153686 LCORL,LCORL EXON Silent,Silent rs16895878 4 17847281 [A/C] NR_136669,NM_153686 LCORL,LCORL EXON Silent,Silent rs16895888 4 17853921 [A/G] NR_136669,NM_153686 LCORL,LCORL Silent,Silent rs6842303 4 17854055 [T/G] NR_136669,NM_153686 LCORL,LCORL Silent,Silent rs16895895 4 17854768 [T/C] NR_136669,NM_153686 LCORL,LCORL Silent,Silent rs10009745 4 17888166 [G/C] NR_136669,NM_153686,NM_001166139 LCORL,LCORL,LCORL Silent,Silent,Silent rs925098 4 17919811 [A/G] NR_136669,NM_153686,NM_001166139 LCORL,LCORL,LCORL Silent,Silent,Silent rs1506613 4 17948939 [T/C] NR_136669,NM_153686,NM_001166139 LCORL,LCORL,LCORL Silent,Silent,Silent rs16896109 4 17950826 [T/C] NR_136669,NM_153686,NM_001166139 LCORL,LCORL,LCORL Silent,Silent,Silent rs7684221 4 17957354 [A/G] NR_136669,NM_153686,NM_001166139 LCORL,LCORL,LCORL Silent,Silent,Silent rs6853216 4 17970655 [T/C] NR_136669,NM_153686,NM_001166139 LCORL,LCORL,LCORL Silent,Silent,Silent rs16896210 4 17992332 [A/G] NR_136669,NM_153686,NM_001166139 LCORL,LCORL,LCORL Silent,Silent,Silent rs724577 4 17993410 [A/C] NR_136669,NM_153686,NM_001166139 LCORL,LCORL,LCORL Silent,Silent,Silent rs13116230 4 18004014 [A/G] NR_136669,NM_153686,NM_001166139 LCORL,LCORL,LCORL Silent,Silent,Silent rs11936089 4 18011864 [T/C] NR_136669,NM_153686,NM_001166139 LCORL,LCORL,LCORL Silent,Silent,Silent rs2061455 4 18035250 [A/G] rs10033699 4 18037800 [A/G] rs1459331 4 18049335 [A/G] rs7691089 4 18060833 [T/C] rs4698667 4 18073943 [T/C] rs9291662 4 18079517 [A/G] rs10939765 4 18082734 [T/C] rs10516319 4 18087325 [T/G] rs7700098 4 18102216 [T/C] rs10004929 4 18111823 [T/C] rs6825385 4 18122542 [A/G] rs6854314 4 18124727 [T/C] rs6854692 4 18124909 [T/G] rs1503872 4 18131245 [T/G] rs7687236 4 18135757 [T/C] rs7684006 4 18140181 [A/G] rs11934728 4 18147151 [T/C] rs1847401 4 18169817 [T/C] rs1503886 4 18169922 [T/G] rs2320467 4 18179501 [A/C] rs4698221 4 18181274 [A/G] rs16896557 4 18181391 [T/G] rs6449361 4 18191999 [A/G] rs13150576 4 18193446 [A/G] rs6449362 4 18194063 [A/C] rs6856758 4 18195120 [T/C] rs1394084 4 18202615 [A/G] rs13106632 4 18203435 [T/C] rs1503884 4 18207538 [T/G] rs4698673 4 18208997 [T/G] rs1503888 4 18218019 [T/C] rs10009303 4 18218684 [T/C] rs6841071 4 18220536 [T/C] rs6811915 4 18243314 [T/G] rs17527941 4 18246425 [A/G] rs10488994 4 18250003 [A/G] rs4356908 4 18255647 [T/C] rs2192521 4 18264644 [A/G] rs2110497 4 18272243 [T/C] rs6836877 4 18274996 [T/G] rs9291670 4 18277716 [A/G] rs1558588 4 18280561 [A/C] rs10488992 4 18281475 [A/G] rs4505820 4 18282476 [T/C] rs13147572 4 18293144 [A/G] rs16896868 4 18293651 [T/C] rs11730060 4 18296221 [T/C] rs7687155 4 18297147 [A/G] rs16896934 4 18315750 [T/C] rs4140904 4 18315992 [A/G] rs741207 4 18321092 [T/C] rs7693245 4 18321896 [T/C] rs6849596 4 18325391 [T/G] rs11733969 4 18377649 [T/C] rs2160107 4 18381481 [T/G] rs1395099 4 18382212 [T/G] rs6833761 4 18396021 [A/G] rs10019574 4 18407127 [A/C] rs6843156 4 18408920 [T/C] rs10001188 4 18412555 [A/G] rs4698690 4 18417138 [A/G] rs1477897 4 18428797 [A/G] rs976812 4 18432045 [A/G] rs13114254 4 18433540 [A/G] rs12646743 4 18437923 [A/G] rs13140382 4 18442072 [A/G] rs10022178 4 18448350 [A/G] rs13136984 4 18453713 [A/G] rs10034918 4 18461495 [T/C] rs11728685 4 18465884 [A/G] rs1354676 4 18473310 [T/C] rs10516323 4 18481635 [A/G] rs16897089 4 18482287 [A/G] rs11936950 4 18502355 [T/C] rs1477892 4 18511288 [A/G] rs1075227 4 18512526 [T/C] rs1477886 4 18515483 [T/C] rs2616472 4 18522138 [A/C] rs13128839 4 18553345 [A/G] rs12507985 4 18569229 [T/G] rs2643431 4 18572708 [A/G] rs4235396 4 18575715 [A/G] rs922388 4 18581701 [A/C] rs2616475 4 18590202 [A/C] rs6835867 4 18596590 [T/C] rs10021749 4 18605502 [A/G] rs11734672 4 18609772 [A/G] rs7696154 4 18612043 [A/G] rs16897260 4 18617189 [A/C] rs6449399 4 18617775 [T/C] rs716985 4 18627512 [T/G] rs4698702 4 18629525 [A/C] rs2320979 4 18638021 [T/C] rs4235399 4 18665579 [T/C] rs4398521 4 18668957 [T/C] rs12505952 4 18670019 [T/C] rs12501690 4 18682975 [T/G] rs938841 4 18694002 [A/C] rs13118998 4 18695770 [A/G] rs1546658 4 18696592 [A/G] rs7656740 4 18701138 [A/G] rs16897436 4 18704754 [A/G] rs7656712 4 18709859 [A/C] rs1878644 4 18722405 [A/G] rs1400938 4 18725182 [T/C] rs2321533 4 18725802 [A/G] rs1517986 4 18737869 [A/G] rs1400931 4 18752731 [A/C] rs16897498 4 18752760 [T/G] rs2203758 4 18753186 [A/G] rs4697637 4 18754324 [T/C] rs1464189 4 18756789 [A/G] rs16897505 4 18757927 [T/G] rs1400935 4 18773006 [T/C] rs1607309 4 18776097 [T/C] rs10024472 4 18779280 [T/C] rs1517987 4 18779862 [A/C] rs10027565 4 18786401 [A/G] rs2321454 4 18787232 [A/G] rs1568234 4 18789372 [A/G] rs9291679 4 18794118 [A/G] rs16897583 4 18794800 [A/G] rs1812449 4 18795170 [T/C] rs4147045 4 18795330 [T/C] rs10000965 4 18797516 [A/G] rs4566649 4 18800428 [A/G] rs13147495 4 18800595 [A/G] rs1356472 4 18801755 [A/C] rs10516330 4 18803401 [T/C] rs16897611 4 18803428 [A/C] rs10516329 4 18803502 [T/C] rs1356468 4 18812552 [T/G] rs12640123 4 18813683 [A/G] rs1518004 4 18820015 [T/G] rs1914609 4 18820686 [A/G] rs1517999 4 18833254 [T/C] rs6449425 4 18835874 [T/C] rs16897644 4 18837642 [A/G] rs4147043 4 18839839 [T/C] rs4147042 4 18840158 [A/G] rs7699469 4 18841225 [A/C] rs4697158 4 18841427 [A/C] rs1518002 4 18843657 [A/G] rs938840 4 18851987 [T/G] rs16897709 4 18852745 [A/G] rs6845544 4 18863913 [A/G] rs6845621 4 18866169 [A/G] rs6819510 4 18869343 [T/C] rs6832325 4 18878845 [T/C] rs7676193 4 18889088 [A/G] rs4254763 4 18894117 [A/G] rs4444827 4 18894787 [T/C] rs12508082 4 18900428 [A/G] rs6449435 4 18908518 [T/C] rs2215762 4 18910602 [A/G] rs6449436 4 18916658 [A/G] rs207291 4 18921383 [T/G] rs10489055 4 18933156 [A/G] rs1452556 4 18936647 [A/G] rs207283 4 18937840 [T/G] rs7664024 4 18944656 [T/C] rs2601573 4 18954655 [T/C] rs1452559 4 18958075 [T/C] rs2537942 4 18960220 [A/G] rs1452565 4 18961510 [A/G] rs1349670 4 18968306 [T/C] rs2601593 4 18983905 [A/C] rs2537914 4 18985469 [T/C] rs207397 4 18990266 [T/C] rs207363 4 19005988 [T/C] rs16897980 4 19020766 [A/G] rs207348 4 19024888 [A/G] rs16897986 4 19026072 [A/G] rs16897993 4 19027525 [A/G] rs10001989 4 19035608 [A/G] rs207343 4 19036305 [T/C] rs207342 4 19038807 [A/G] rs12644264 4 19040579 [A/G] rs16898029 4 19047617 [T/C] rs16898037 4 19056475 [A/G] rs207332 4 19058245 [T/C] rs16898044 4 19058288 [T/G] rs207331 4 19059824 [T/C] rs207311 4 19075878 [T/C] rs182289 4 19087520 [A/G] rs207305 4 19092157 [T/C] rs16898064 4 19093088 [T/C] rs207301 4 19095959 [A/G] rs207300 4 19096163 [T/C] rs10020700 4 19101375 [A/G] rs13113040 4 19107962 [T/C] rs12649695 4 19111493 [T/C] rs6815911 4 19116730 [T/C] rs11931960 4 19118335 [T/G] rs17495360 4 19119813 [T/C] rs17495401 4 19120064 [A/G] rs10461114 4 19122442 [A/G] rs13125998 4 19129715 [A/G] rs9992304 4 19133988 [T/C] rs2169705 4 19136574 [A/G] rs7671224 4 19150192 [A/C] rs5013969 4 19150738 [T/C] rs1351073 4 19160427 [T/C] rs13139953 4 19167507 [A/G] rs12374356 4 19174530 [T/C] rs11944202 4 19186822 [A/C] rs1478051 4 19189389 [T/G] rs1478049 4 19193583 [A/G] rs12506297 4 19201819 [T/C] rs17562900 4 19217517 [A/G] rs10026058 4 19236267 [A/C] rs1382155 4 19239803 [A/G] rs414289 4 19253659 [T/C] rs312361 4 19258863 [A/C] rs7668345 4 19259307 [A/G] rs312357 4 19259854 [A/C] rs312353 4 19262251 [T/C] rs1026681 4 19262896 [A/G] rs1478046 4 19265758 [T/C] rs16898171 4 19267283 [T/C] rs312368 4 19275229 [A/G] rs16898189 4 19300513 [T/C] rs17564753 4 19302457 [A/C] rs312330 4 19306711 [T/C] rs724516 4 19318965 [A/G] rs2322090 4 19326717 [A/C] rs1010743 4 19333182 [A/C] rs1490874 4 19335464 [T/C] rs12642807 4 19368572 [A/G] rs9291401 4 19403147 [T/G] rs13123977 4 19406545 [T/C] rs13102773 4 19407186 [T/C] rs10023012 4 19410177 [A/G] rs16898258 4 19411691 [T/C] rs7696764 4 19414766 [T/C] rs10010555 4 19424787 [T/C] rs6829074 4 19425386 [T/C] rs4074143 4 19428544 [A/G] rs10009055 4 19445650 [A/C] rs12233736 4 19452605 [T/C] rs10004437 4 19463717 [A/G] rs4610333 4 19474680 [T/C] rs7437307 4 19484765 [T/G] rs7683977 4 19487028 [T/C] rs10011402 4 19488871 [T/G] rs4525972 4 19492256 [A/G] rs10017144 4 19496230 [A/G] rs4346638 4 19497475 [A/G] rs4586931 4 19506054 [T/C] rs6837423 4 19511507 [A/G] rs10006185 4 19512213 [A/G] rs12507186 4 19517296 [T/C] rs7700114 4 19525991 [T/C] rs4478186 4 19551260 [A/G] rs6850501 4 19570941 [A/G] rs13120547 4 19571122 [T/C] rs9996345 4 19573855 [A/G] rs10027409 4 19574923 [T/C] rs4295256 4 19576080 [A/G] rs12511971 4 19576271 [T/C] rs10000908 4 19576975 [T/C] rs17508080 4 19584331 [A/G] rs11937925 4 19589352 [T/C] rs10033656 4 19607089 [T/C] rs3846382 4 19609939 [T/C] rs3904756 4 19616531 [T/C] rs10025939 4 19616649 [A/C] rs7682588 4 19617286 [A/G] rs3846385 4 19629309 [A/G] rs3846388 4 19633338 [A/G] rs11939712 4 19643571 [A/G] rs17570168 4 19684918 [T/C] rs3842911 4 19696428 [T/C] rs9291405 4 19717625 [A/C] rs4696937 4 19724641 [A/G] rs10029490 4 19740879 [A/C] rs3935613 4 19751585 [T/G] rs13137813 4 19753174 [A/G] rs4525973 4 19763176 [A/G] rs13145150 4 19798055 [T/C] rs10938771 4 19800481 [T/C] rs4380519 4 19810878 [A/G] rs4315783 4 19810968 [T/G] rs7658418 4 19821565 [T/C] rs6833662 4 19827258 [A/G] rs6447929 4 19831621 [T/C] rs4261984 4 19832995 [T/C] rs6833091 4 19834012 [T/G] rs6844265 4 19840731 [T/G] rs6852734 4 19842636 [T/C] rs4516715 4 19847106 [A/G] rs12649350 4 19857997 [A/G] rs4582148 4 19863785 [A/G] rs7693487 4 19872318 [A/G] rs10516339 4 19873071 [A/G] rs4404540 4 19875509 [T/C] rs6858624 4 19896225 [A/G] rs11733327 4 19899630 [A/G] rs12512109 4 19901649 [T/C] rs11735138 4 19906275 [T/C] rs41532447 4 19915956 [A/G] rs6816464 4 19928602 [T/C] rs4464568 4 19933069 [T/C] rs17586630 4 19934939 [T/C] rs12650682 4 19942443 [A/G] rs13135681 4 19971235 [A/G] rs4549380 4 19972465 [A/G] rs10516343 4 19974862 [A/C] rs4128232 4 19980071 [T/C] rs4626202 4 19983104 [T/C] rs2629722 4 19992481 [A/C] rs2247321 4 19998503 [T/C] rs991645 4 20011236 [A/G] rs2629715 4 20020240 [A/C] rs7684055 4 20025385 [T/G] rs13107783 4 20025539 [A/C] rs2708987 4 20032963 [T/C] rs13148770 4 20043516 [T/C] rs1872469 4 20050184 [A/C] rs901123 4 20050733 [A/G] rs1032133 4 20053908 [T/C] rs6845174 4 20054356 [A/G] rs10018142 4 20063063 [T/C] rs2874743 4 20064263 [T/C] rs28461290 4 20069071 [T/C] rs961521 4 20078019 [T/C] rs10938787 4 20088468 [A/G] rs4642249 4 20089011 [A/G] rs2322346 4 20097540 [A/G] rs4697140 4 20100285 [A/C] rs6852889 4 20108488 [A/G] rs6855958 4 20111944 [T/C] rs13123715 4 20112399 [T/C] rs1872467 4 20117416 [A/G] rs10516346 4 20118073 [A/C] rs16869206 4 20123954 [A/C] rs16869213 4 20126912 [T/C] rs6826653 4 20127041 [T/C] rs12510334 4 20141256 [T/G] rs16869279 4 20159847 [T/C] rs11727186 4 20164834 [T/C] rs1436294 4 20168391 [T/C] rs13117394 4 20169556 [T/C] rs7659298 4 20171488 [T/C] rs10027583 4 20176829 [T/C] rs11935694 4 20183673 [A/G] rs17598758 4 20190068 [T/G] rs587668 4 20190972 [T/C] rs12507342 4 20193573 [A/C] rs1165446 4 20206183 [T/C] rs685064 4 20206215 [T/C] rs534860 4 20211471 [T/C] rs812652 4 20213740 [T/C] rs556208 4 20214277 [T/C] rs1923841 4 20216543 [A/C] rs10516353 4 20229030 [T/C] rs509217 4 20230757 [T/C] rs544236 4 20235828 [T/C] rs559767 4 20242529 [A/G] rs507134 4 20244146 [T/G] rs640501 4 20249840 [T/C] rs614158 4 20251117 [T/C] rs4552453 4 20254298 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 EXON Silent,Silent,Silent rs7655084 4 20255306 [T/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 EXON Silent,Silent,Silent rs1323067 4 20262768 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs1323068 4 20263058 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs2322460 4 20263431 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs715213 4 20267915 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs587032 4 20271773 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs16869461 4 20275477 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs6447952 4 20276252 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs16869481 4 20282334 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs17601458 4 20283069 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs7674173 4 20288024 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs7680945 4 20289373 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs593943 4 20292239 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs12511950 4 20303108 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs1323062 4 20309742 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs13434430 4 20310173 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs13435197 4 20310276 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs12646142 4 20318837 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs9993087 4 20322789 [A/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs4696953 4 20322913 [A/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs10938796 4 20327010 [A/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs12503652 4 20333722 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs12502618 4 20334919 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs6447955 4 20347939 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs4406013 4 20362716 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs5016268 4 20370143 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs4403045 4 20377167 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs9884539 4 20380257 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs10002000 4 20383790 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs4552454 4 20386044 [A/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs13142826 4 20391615 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs9996157 4 20405032 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs17609702 4 20425588 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs11723573 4 20440256 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs1473080 4 20444781 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs884770 4 20447040 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs16869609 4 20449733 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs16869615 4 20454884 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs9990844 4 20455955 [A/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs11733205 4 20458688 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs11942897 4 20459118 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs1033111 4 20467767 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs11936122 4 20473278 [T/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs16869641 4 20476296 [T/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs625614 4 20476800 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs16869642 4 20479498 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs16869643 4 20479620 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs16869665 4 20486230 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs10019416 4 20487711 [A/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs484614 4 20488464 [A/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs3756147 4 20489479 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs4443280 4 20490667 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs522501 4 20497277 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs6825654 4 20518603 [A/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs519813 4 20520993 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs16869706 4 20524715 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs2292438 4 20525537 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs7690660 4 20527864 [T/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs3775815 4 20529670 [T/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs9992559 4 20530374 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs2168801 4 20530981 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs2322557 4 20533014 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs632152 4 20533034 [A/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs663032 4 20533991 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs6816854 4 20534467 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs520535 4 20535876 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs12512830 4 20537784 [T/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs3775820 4 20540540 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs16869739 4 20543709 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs675465 4 20543817 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs664208 4 20544053 [A/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs7690492 4 20544184 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 EXON Synonymous_V737V,Synonymous_V729V,Synonymous_V733V rs7669094 4 20544416 [T/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs3775824 4 20544912 [T/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs3775827 4 20545314 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs11936468 4 20548976 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs17542486 4 20552510 [A/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 EXON Synonymous_A850A,Synonymous_A842A,Synonymous_A846A rs4697169 4 20552853 [A/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs7692811 4 20562080 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs10516357 4 20563108 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs506358 4 20565861 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs1870260 4 20566866 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs2290750 4 20569099 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs7666974 4 20579372 [T/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs2168802 4 20585883 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs9992598 4 20599591 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs12507257 4 20599796 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs10010466 4 20601311 [T/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs2322559 4 20605594 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs12511349 4 20608975 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs3733510 4 20611629 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs9993853 4 20612056 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs17544103 4 20619890 [T/C] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 Silent,Silent,Silent rs8663 4 20621690 [A/G] NM_004787,NM_001289136,NM_001289135 SLIT2,SLIT2,SLIT2 EXON Silent,Silent,Silent rs11930632 4 20623976 [T/C] rs16869812 4 20627764 [T/C] rs936359 4 20628259 [A/C] rs1465522 4 20637946 [A/G] rs6824850 4 20640647 [A/G] rs10015865 4 20652297 [T/C] rs10024417 4 20660406 [T/C] rs967942 4 20663866 [T/C] rs7686201 4 20669957 [T/G] rs10805218 4 20674741 [T/G] rs10755201 4 20674761 [T/C] rs2195033 4 20685983 [T/C] rs1365580 4 20687802 [T/G] rs11736062 4 20692096 [T/C] rs16869853 4 20692580 [A/G] rs10938801 4 20696980 [A/G] rs3764967 4 20714719 [A/C] NR_133933,NR_047661,NM_001130727,NM_001258345,NM_001330745,NM_001330746,NM_001258346,NM_001330747,NM_001317849,NM_145048,NM_001330748 PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11721944 4 20717173 [A/G] NR_133933,NR_047661,NM_001130727,NM_001258345,NM_001330745,NM_001330746,NM_001258346,NM_001330747,NM_001317849,NM_145048,NM_001330748 PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11722085 4 20717561 [A/G] NR_133933,NR_047661,NM_001130727,NM_001258345,NM_001330745,NM_001330746,NM_001258346,NM_001330747,NM_001317849,NM_145048,NM_001330748 PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9291412 4 20727464 [A/G] NR_133933,NR_047661,NM_001130727,NM_001258345,NM_001330745,NM_001330746,NM_001258346,NM_001330747,NM_001317849,NM_145048,NM_001330748 PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13145309 4 20729194 [T/G] NR_133933,NR_047661,NM_001130727,NM_001258345,NM_001330745,NM_001330746,NM_001258346,NM_001330747,NM_001317849,NM_145048,NM_001330748 PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6811030 4 20730601 [T/C] NR_133933,NR_047661,NM_001130727,NM_001258345,NM_001330745,NM_001330746,NM_001258346,NM_001330747,NM_001317849,NM_145048,NM_001330748,NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16869915 4 20730780 [A/C] NR_133933,NR_047661,NM_001130727,NM_001258345,NM_001330745,NM_001330746,NM_001258346,NM_001330747,NM_001317849,NM_145048,NM_001330748,NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2288308 4 20731047 [T/C] NR_133933,NR_047661,NM_001130727,NM_001258345,NM_001330745,NM_001330746,NM_001258346,NM_001330747,NM_001317849,NM_145048,NM_001330748,NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12640448 4 20731332 [T/C] NR_133933,NR_047661,NM_001130727,NM_001258345,NM_001330745,NM_001330746,NM_001258346,NM_001330747,NM_001317849,NM_145048,NM_001330748,NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7688805 4 20732334 [A/C] NR_133933,NR_047661,NM_001130727,NM_001258345,NM_001330745,NM_001330746,NM_001258346,NM_001330747,NM_001317849,NM_145048,NM_001330748,NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,PACRGL,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6447978 4 20736742 [T/C] NR_133933,NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 PACRGL,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10084802 4 20746450 [A/G] NR_133933,NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 PACRGL,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10938803 4 20749299 [A/G] NR_133933,NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 PACRGL,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2322688 4 20751278 [A/G] NR_133933,NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 PACRGL,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7689421 4 20755240 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6832227 4 20760046 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7657542 4 20765867 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7686877 4 20767337 [A/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16869940 4 20767378 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13129008 4 20769558 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16869949 4 20770444 [A/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3857162 4 20771062 [A/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13137029 4 20773916 [T/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10938805 4 20776516 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16869959 4 20780035 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6843196 4 20796706 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9998730 4 20798129 [T/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4697184 4 20801649 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16869987 4 20805765 [A/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12641748 4 20806697 [T/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16870017 4 20807977 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1863633 4 20809664 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1863632 4 20809704 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16870076 4 20814133 [T/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9998323 4 20814178 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9998327 4 20814216 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1873530 4 20815387 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12501548 4 20820088 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6838129 4 20820808 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11734471 4 20821110 [A/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10013103 4 20827366 [A/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs976376 4 20828809 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12649113 4 20831331 [A/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17555380 4 20832402 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10020916 4 20834659 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs902665 4 20834721 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10025134 4 20836574 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2130920 4 20836911 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11932876 4 20838476 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1352797 4 20841386 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10001877 4 20843206 [T/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11735642 4 20849761 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10805220 4 20850439 [A/C] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4697192 4 20851050 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3765121 4 20852166 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 EXON Synonymous_N34N,Synonymous_N71N,Synonymous_N42N,Synonymous_N75N,Synonymous_N76N,Synonymous_N34N,Synonymous_N79N rs3765122 4 20852244 [A/G] NM_001035004,NM_001035003,NM_147181,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 EXON Synonymous_P8P,Synonymous_P45P,Synonymous_P16P,Synonymous_P49P,Synonymous_P50P,Synonymous_P8P,Synonymous_P53P rs16870149 4 20857804 [T/G] NM_001035004,NM_001035003,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent rs9291414 4 20861179 [T/G] NM_001035004,NM_001035003,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent rs17556698 4 20861514 [T/C] NM_001035004,NM_001035003,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent rs17556817 4 20864229 [T/C] NM_001035004,NM_001035003,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent rs6835474 4 20866065 [A/G] NM_001035004,NM_001035003,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent rs17632612 4 20875314 [A/G] NM_001035004,NM_001035003,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent rs17632634 4 20875574 [A/G] NM_001035004,NM_001035003,NM_147183,NM_025221,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent,Silent rs10516368 4 20885254 [A/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs7679910 4 20891419 [A/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs13143622 4 20892799 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs1352796 4 20894093 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs7670834 4 20895013 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs7677781 4 20896318 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs1565534 4 20898220 [A/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs1491370 4 20908415 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs6843757 4 20914984 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs12500896 4 20923261 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs6849543 4 20926006 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs1434957 4 20926819 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs1114663 4 20930535 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs16870225 4 20939335 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs4697198 4 20939779 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs1434954 4 20946907 [A/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs6830607 4 20948059 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs12642219 4 20948335 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs6448000 4 20948497 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs1434950 4 20949917 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs7677635 4 20951955 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs6811024 4 20952556 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs6821566 4 20959057 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs1434943 4 20960640 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs17573138 4 20972919 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs6841954 4 20985138 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182,NM_001363504 KCNIP4,KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent,Silent rs17635673 4 20987443 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs7675477 4 20995935 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs12640604 4 21000867 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs12504474 4 21001815 [T/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6825511 4 21002294 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs10034991 4 21005251 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs10938823 4 21007589 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6830976 4 21008300 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs9631707 4 21010644 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs12644707 4 21011157 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs4348088 4 21019900 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs13133807 4 21021688 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs4389575 4 21022508 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6825103 4 21026460 [T/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6819439 4 21028953 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6853609 4 21033853 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs10938827 4 21041975 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs10033946 4 21052369 [A/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6854888 4 21057559 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6448009 4 21059144 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs12510687 4 21079749 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6817687 4 21085330 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6448011 4 21089763 [A/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs10938829 4 21094428 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs720853 4 21096145 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs1368645 4 21104154 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs7696887 4 21112046 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6846038 4 21113871 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs11944192 4 21114825 [A/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs12649359 4 21115228 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs16870400 4 21115516 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs16870421 4 21116890 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs5027019 4 21118914 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs7687191 4 21125935 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6448023 4 21138108 [T/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs1433482 4 21138383 [T/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs10011670 4 21140045 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs10007205 4 21141832 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs17446667 4 21151856 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs17506318 4 21155716 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs4580648 4 21155998 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs876478 4 21156962 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs10021509 4 21157111 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs7667000 4 21159965 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs1347240 4 21160249 [A/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs17513440 4 21175390 [A/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs10516374 4 21175619 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs2113966 4 21179758 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs16870541 4 21180383 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs16870545 4 21180936 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs1319225 4 21180995 [T/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs7655488 4 21183041 [T/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs10013055 4 21188231 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs1364841 4 21191990 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs13117927 4 21198867 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6448033 4 21200024 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6448037 4 21215907 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs7672506 4 21220921 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs10516376 4 21222671 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs11733487 4 21236883 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6833463 4 21244175 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs1967398 4 21254536 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs1425333 4 21255650 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs4697213 4 21256272 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6827486 4 21257521 [T/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs10018523 4 21260528 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs12648055 4 21261499 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs11722994 4 21263330 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs1863289 4 21265036 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs16870654 4 21267346 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs17458108 4 21274461 [A/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs2322883 4 21275159 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs901113 4 21276080 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs16870697 4 21277772 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6850985 4 21281970 [A/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs993611 4 21286777 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs4696973 4 21292213 [T/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs13111323 4 21295315 [A/G] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs6858452 4 21296926 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs16870742 4 21300220 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs1425339 4 21300290 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs2007762 4 21301546 [A/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs16870748 4 21303220 [T/C] NM_001035004,NM_001035003,NM_147183,NM_147182 KCNIP4,KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent,Silent rs16870755 4 21306003 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs13101486 4 21306185 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs11726974 4 21307467 [T/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs11734360 4 21310634 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs16870778 4 21314419 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs16870787 4 21316612 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs12504236 4 21317053 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs17520130 4 21324191 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1364836 4 21333411 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs16870831 4 21334285 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs16870839 4 21336070 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs16870854 4 21339092 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1485513 4 21341637 [T/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs10516382 4 21341912 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs16870875 4 21343377 [T/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs16870878 4 21344139 [A/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs17520919 4 21348980 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs7661530 4 21351260 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs17521122 4 21351470 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs12501359 4 21361701 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs2323001 4 21368339 [A/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1994983 4 21377097 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs12641447 4 21382332 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1390262 4 21387660 [T/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs6852605 4 21388219 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs7654061 4 21389123 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1908552 4 21389678 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1495509 4 21393616 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs13113329 4 21393750 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs10012593 4 21401617 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs10026043 4 21407094 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs6448050 4 21407759 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1874341 4 21415503 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs4697220 4 21419053 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs2322963 4 21424434 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs10022151 4 21425057 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs11730849 4 21438786 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1476279 4 21452250 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs168583 4 21453446 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs358574 4 21455396 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1460485 4 21455877 [A/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs358573 4 21456023 [T/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs358569 4 21461121 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs6855589 4 21471568 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs17523841 4 21472214 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1460491 4 21472843 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs9291427 4 21473131 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs17523974 4 21475938 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs358592 4 21476990 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1460492 4 21477084 [A/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs358591 4 21477096 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs358580 4 21488871 [T/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs4314271 4 21489423 [A/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1565947 4 21490361 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs6830109 4 21492445 [T/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs10025003 4 21493467 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1013568 4 21494694 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1841369 4 21502444 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs6820184 4 21503179 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs10516390 4 21504820 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs358558 4 21506851 [A/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs16871289 4 21511383 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs17467572 4 21511850 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs6810518 4 21514249 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs2279674 4 21520250 [T/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs1460494 4 21526226 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs11734403 4 21539014 [A/G] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 Silent,Silent,Silent rs870368 4 21546217 [T/C] NM_001035004,NM_001035003,NM_147182 KCNIP4,KCNIP4,KCNIP4 EXON Silent,Silent,Silent rs1817324 4 21546537 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs13115047 4 21549276 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs2009807 4 21551976 [A/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs2199286 4 21558828 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs12498693 4 21560356 [A/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs13119355 4 21562013 [A/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs358840 4 21562391 [A/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs358839 4 21565222 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs16871434 4 21565393 [A/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs1460475 4 21565822 [A/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs16871442 4 21566178 [A/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs6448057 4 21566484 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs16871465 4 21569545 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs1604805 4 21571087 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs17483325 4 21571755 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs402802 4 21572845 [A/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs1966048 4 21575623 [A/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs16871486 4 21577089 [A/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs7657068 4 21581191 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs6843837 4 21582320 [A/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs11722935 4 21590684 [A/G] NM_001035003,NM_147182,NR_134233 KCNIP4,KCNIP4,LOC105374516 Silent,Silent,Silent rs17557643 4 21601372 [A/G] NM_001035003,NM_147182,NR_134233 KCNIP4,KCNIP4,LOC105374516 Silent,Silent,Silent rs12504857 4 21601449 [A/C] NM_001035003,NM_147182,NR_134233 KCNIP4,KCNIP4,LOC105374516 Silent,Silent,Silent rs1827593 4 21602926 [A/G] NM_001035003,NM_147182,NR_134233 KCNIP4,KCNIP4,LOC105374516 Silent,Silent,Silent rs3913663 4 21607597 [T/G] NM_001035003,NM_147182,NR_134233 KCNIP4,KCNIP4,LOC105374516 Silent,Silent,Silent rs7676653 4 21614184 [T/C] NM_001035003,NM_147182,NR_134233 KCNIP4,KCNIP4,LOC105374516 Silent,Silent,Silent rs6826086 4 21614663 [T/C] NM_001035003,NM_147182,NR_134233 KCNIP4,KCNIP4,LOC105374516 Silent,Silent,Silent rs12647718 4 21614825 [T/C] NM_001035003,NM_147182,NR_134233 KCNIP4,KCNIP4,LOC105374516 Silent,Silent,Silent rs16871591 4 21615355 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs9291428 4 21622448 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs2340 4 21622793 [A/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs12502842 4 21624110 [A/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs2323070 4 21627809 [A/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs10516395 4 21628375 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs1039549 4 21629865 [T/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs6448063 4 21632162 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs6832022 4 21633160 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs1503979 4 21634922 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs10011134 4 21646932 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs10014328 4 21647862 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs1503990 4 21651620 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs6817879 4 21651850 [T/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs1026523 4 21655717 [A/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs1026522 4 21655863 [A/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs7666642 4 21658285 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs1824371 4 21658543 [A/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs6843682 4 21661079 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs4697227 4 21663995 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs7671181 4 21671519 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs13145193 4 21671589 [T/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs4697230 4 21673431 [A/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs17495164 4 21678262 [T/C] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs1354390 4 21689430 [A/G] NM_001035003,NM_147182 KCNIP4,KCNIP4 Silent,Silent rs2167246 4 21701301 [T/C] NM_147182 KCNIP4 Silent rs1459282 4 21707600 [A/G] NM_147182 KCNIP4 Silent rs4235291 4 21707905 [T/C] NM_147182 KCNIP4 Silent rs1459283 4 21708295 [T/C] NM_147182 KCNIP4 Silent rs7669417 4 21709938 [A/G] NM_147182 KCNIP4 Silent rs1503976 4 21712050 [A/G] NM_147182 KCNIP4 Silent rs6850480 4 21715034 [T/C] NM_147182 KCNIP4 Silent rs9884923 4 21719296 [T/C] NM_147182 KCNIP4 Silent rs11721958 4 21726861 [T/C] NM_147182 KCNIP4 Silent rs12509958 4 21734047 [A/C] NM_147182 KCNIP4 Silent rs7697475 4 21735319 [A/G] NM_147182 KCNIP4 Silent rs1450730 4 21738299 [A/C] NM_147182 KCNIP4 Silent rs6838195 4 21751771 [T/C] NM_147182 KCNIP4 Silent rs1380270 4 21755399 [T/C] NM_147182 KCNIP4 Silent rs717531 4 21764761 [T/C] NM_147182 KCNIP4 Silent rs16871866 4 21765615 [T/C] NM_147182 KCNIP4 Silent rs16871885 4 21769360 [T/C] NM_147182 KCNIP4 Silent rs12646630 4 21770028 [T/C] NM_147182 KCNIP4 Silent rs1471220 4 21778153 [T/C] NM_147182 KCNIP4 Silent rs896120 4 21789525 [T/C] NM_147182 KCNIP4 Silent rs10021705 4 21793217 [A/G] NM_147182 KCNIP4 Silent rs11939307 4 21793901 [T/C] NM_147182 KCNIP4 Silent rs7696044 4 21794660 [A/C] NM_147182 KCNIP4 Silent rs4631029 4 21796070 [A/G] NM_147182 KCNIP4 Silent rs6827460 4 21798225 [T/C] NM_147182 KCNIP4 Silent rs10516401 4 21798443 [A/G] NM_147182 KCNIP4 Silent rs10516402 4 21798563 [T/C] NM_147182 KCNIP4 Silent rs10034770 4 21820620 [A/C] NM_147182 KCNIP4 Silent rs4377576 4 21825726 [T/C] NM_147182 KCNIP4 Silent rs2137650 4 21833931 [A/G] NM_147182 KCNIP4 Silent rs957196 4 21842795 [T/C] NM_147182 KCNIP4 Silent rs1398832 4 21847547 [T/C] NM_147182,NR_002813 KCNIP4,KCNIP4-IT1 EXON Silent,Silent rs966045 4 21848082 [T/C] NM_147182,NR_002813 KCNIP4,KCNIP4-IT1 EXON Silent,Silent rs1398835 4 21849857 [T/C] NM_147182,NR_002813 KCNIP4,KCNIP4-IT1 EXON Silent,Silent rs1513572 4 21850305 [T/C] NM_147182,NR_002813 KCNIP4,KCNIP4-IT1 EXON Silent,Silent rs13136049 4 21852757 [A/G] NM_147182,NR_002813 KCNIP4,KCNIP4-IT1 EXON Silent,Silent rs6836067 4 21857603 [T/G] NM_147182 KCNIP4 Silent rs6852952 4 21864975 [A/G] NM_147182 KCNIP4 Silent rs4697244 4 21866646 [T/C] NM_147182 KCNIP4 Silent rs6839725 4 21870314 [A/G] NM_147182 KCNIP4 Silent rs12504827 4 21871986 [A/G] NM_147182 KCNIP4 Silent rs872995 4 21875994 [A/G] NM_147182 KCNIP4 Silent rs10009391 4 21877250 [T/C] NM_147182 KCNIP4 Silent rs10516407 4 21883570 [T/C] NM_147182 KCNIP4 Silent rs4697247 4 21887265 [T/C] NM_147182 KCNIP4 Silent rs10000092 4 21895517 [T/C] NM_147182 KCNIP4 Silent rs4277766 4 21910553 [T/C] NM_147182 KCNIP4 Silent rs2874977 4 21911866 [T/G] NM_147182 KCNIP4 Silent rs9995524 4 21913523 [T/G] NM_147182 KCNIP4 Silent rs1398837 4 21916439 [T/C] NM_147182 KCNIP4 Silent rs1398838 4 21916709 [A/C] NM_147182 KCNIP4 Silent rs727633 4 21920543 [T/C] NM_147182 KCNIP4 Silent rs2203274 4 21921234 [A/C] NM_147182 KCNIP4 Silent rs10938866 4 21922674 [A/C] NM_147182 KCNIP4 Silent rs1913330 4 21929301 [T/C] NM_147182 KCNIP4 Silent rs4697248 4 21931195 [T/C] NM_147182 KCNIP4 Silent rs4697249 4 21938803 [A/G] NM_147182 KCNIP4 Silent rs4697250 4 21940697 [T/G] NM_147182 KCNIP4 Silent rs4696996 4 21962153 [T/C] rs9291431 4 21965464 [T/C] rs11940932 4 21971493 [T/C] rs4697253 4 21972367 [T/C] rs2007195 4 21973217 [T/C] rs11728819 4 21977669 [A/C] rs1533278 4 21978266 [T/G] rs4696998 4 21979317 [T/G] rs9994837 4 21979762 [A/C] rs6827204 4 21981053 [A/G] rs6448104 4 21986877 [T/C] rs7691155 4 22007483 [T/C] rs4697259 4 22013294 [T/C] rs4697261 4 22023593 [T/C] rs6838353 4 22028574 [T/C] rs2175778 4 22030668 [A/G] rs11933737 4 22034546 [A/G] rs13106072 4 22044372 [A/G] rs7695992 4 22048637 [A/G] rs12510345 4 22052817 [A/G] rs10433802 4 22057269 [T/C] rs10031901 4 22060315 [A/G] rs17526294 4 22061205 [A/G] rs6816789 4 22062457 [A/G] rs6448111 4 22064524 [A/G] rs4697263 4 22068673 [A/C] rs6448112 4 22069379 [A/C] rs7656406 4 22073768 [A/C] rs6448117 4 22079213 [T/G] rs11931022 4 22079733 [A/G] rs10017103 4 22080442 [T/C] rs6831346 4 22081816 [A/G] rs13123835 4 22087470 [A/G] rs6851636 4 22090575 [A/G] rs6834054 4 22090754 [T/C] rs6448119 4 22091384 [T/C] rs13149470 4 22094237 [T/G] rs6820902 4 22098163 [T/C] rs7680694 4 22103712 [T/C] rs4590011 4 22106866 [T/C] rs10019171 4 22107318 [T/G] rs6837880 4 22109508 [T/C] rs4697267 4 22111275 [T/C] rs16872408 4 22114968 [T/C] rs17528275 4 22124060 [T/C] rs16872414 4 22135324 [A/G] rs10013629 4 22136957 [A/G] rs10021835 4 22142731 [T/G] rs10033940 4 22161298 [T/G] rs11728484 4 22163667 [T/C] rs11933151 4 22164317 [A/G] rs9291436 4 22165174 [T/C] rs7688470 4 22171998 [A/G] rs10938878 4 22180997 [T/G] rs10026993 4 22185504 [T/C] rs17588445 4 22189941 [A/G] rs4697270 4 22202451 [A/G] rs16872470 4 22203162 [A/G] rs10022457 4 22205496 [A/G] rs6448134 4 22205963 [A/G] rs9997871 4 22220505 [T/G] rs4235294 4 22220925 [A/G] rs11730240 4 22222487 [A/G] rs11727303 4 22222814 [T/C] rs10938882 4 22235324 [T/C] rs4697273 4 22235796 [A/G] rs4697275 4 22237340 [T/G] rs4697003 4 22240923 [A/G] rs11944669 4 22246755 [A/C] rs11940485 4 22256034 [T/G] rs10805233 4 22264837 [A/G] rs4285070 4 22266680 [T/C] rs4697283 4 22277576 [T/C] rs1500453 4 22293243 [T/C] rs7659139 4 22297899 [A/G] rs1500463 4 22300272 [A/G] rs16872505 4 22302327 [T/G] rs1392592 4 22302352 [A/G] rs6448143 4 22303196 [T/C] rs10938886 4 22304073 [T/C] rs6448144 4 22316708 [A/G] rs11929787 4 22321784 [A/C] rs4697007 4 22322240 [T/C] rs7674804 4 22344500 [T/C] rs16872561 4 22344738 [T/C] rs16872565 4 22346400 [T/G] rs1983021 4 22349886 [T/C] rs10005140 4 22365603 [A/G] rs955785 4 22370669 [T/C] rs3814416 4 22389797 [A/C] NM_145290 ADGRA3 EXON Missense_V1166G rs9002 4 22390167 [T/C] NM_145290 ADGRA3 EXON Missense_V1043M rs6855769 4 22391761 [A/G] NM_145290 ADGRA3 Silent rs4697296 4 22396289 [T/C] NM_145290 ADGRA3 Silent rs1846731 4 22397135 [T/C] NM_145290 ADGRA3 Silent rs13148867 4 22397564 [A/C] NM_145290 ADGRA3 Silent rs4697297 4 22401728 [T/C] NM_145290 ADGRA3 Silent rs2306135 4 22403722 [T/C] NM_145290 ADGRA3 Silent rs10002842 4 22414023 [A/C] NM_145290 ADGRA3 Silent rs12331257 4 22414210 [T/C] NM_145290 ADGRA3 Silent rs6821181 4 22416738 [A/G] NM_145290 ADGRA3 Silent rs1392595 4 22427057 [A/G] NM_145290 ADGRA3 Silent rs10805234 4 22428329 [T/C] NM_145290 ADGRA3 Silent rs13135121 4 22430507 [A/G] NM_145290 ADGRA3 Silent rs13110697 4 22433659 [A/G] NM_145290 ADGRA3 Silent rs6448155 4 22435993 [A/G] NM_145290 ADGRA3 Silent rs16872644 4 22436684 [T/C] NM_145290 ADGRA3 Silent rs16872651 4 22439599 [A/C] NM_145290 ADGRA3 Silent rs17532048 4 22440261 [A/G] NM_145290 ADGRA3 Silent rs1463000 4 22441466 [T/G] NM_145290 ADGRA3 Silent rs10018144 4 22444692 [T/C] NM_145290 ADGRA3 Silent rs7657579 4 22447508 [T/C] NM_145290 ADGRA3 Silent rs28726245 4 22450122 [A/G] NM_145290 ADGRA3 Silent rs1564138 4 22451781 [T/C] NM_145290 ADGRA3 Silent rs964549 4 22453260 [T/C] NM_145290 ADGRA3 Silent rs16872686 4 22462730 [T/C] NM_145290 ADGRA3 Silent rs16872711 4 22469890 [T/C] NM_145290 ADGRA3 Silent rs6851006 4 22470618 [T/C] NM_145290 ADGRA3 Silent rs7697959 4 22470931 [T/C] NM_145290 ADGRA3 Silent rs17599392 4 22472251 [A/G] NM_145290 ADGRA3 Silent rs13150142 4 22479781 [A/G] NM_145290 ADGRA3 Silent rs4235298 4 22480252 [T/C] NM_145290 ADGRA3 Silent rs16872734 4 22484933 [A/G] NM_145290 ADGRA3 Silent rs11730156 4 22486548 [A/C] NM_145290 ADGRA3 Silent rs6826101 4 22487956 [T/C] NM_145290 ADGRA3 Silent rs1841823 4 22493757 [T/C] NM_145290 ADGRA3 Silent rs6818597 4 22493834 [T/C] NM_145290 ADGRA3 Silent rs11728370 4 22496882 [A/G] NM_145290 ADGRA3 Silent rs6448161 4 22501043 [T/G] NM_145290 ADGRA3 Silent rs7684229 4 22507775 [T/C] NM_145290 ADGRA3 Silent rs10516410 4 22508257 [A/G] NM_145290 ADGRA3 Silent rs7697048 4 22509714 [T/C] NM_145290 ADGRA3 Silent rs1381915 4 22519313 [T/C] rs2086010 4 22521890 [A/G] rs6838206 4 22530016 [T/C] rs1120044 4 22531986 [T/C] rs10017558 4 22536001 [T/C] rs13143909 4 22537258 [A/G] rs12163757 4 22537387 [A/C] rs10026861 4 22538841 [T/C] rs10027019 4 22538956 [T/G] rs2323624 4 22555317 [A/G] rs11722502 4 22556784 [T/C] rs10446635 4 22559043 [T/C] rs10020835 4 22576366 [T/C] rs2323549 4 22579261 [T/C] rs6813399 4 22581486 [A/G] rs2581963 4 22585550 [A/G] rs13152115 4 22585721 [A/G] rs13120856 4 22591935 [T/C] rs6858626 4 22592929 [A/G] rs11944771 4 22595658 [A/G] rs1824864 4 22605059 [A/C] rs2581987 4 22613279 [T/C] rs1842098 4 22613860 [A/G] rs7654229 4 22614302 [T/G] rs2618940 4 22614378 [T/C] rs2581994 4 22625571 [A/G] rs2581997 4 22627981 [T/G] rs2439468 4 22631389 [T/C] rs2618947 4 22646725 [T/C] rs16872878 4 22648713 [A/G] rs2245395 4 22656105 [T/C] rs2618954 4 22659580 [T/G] rs12507337 4 22661136 [T/C] rs2258846 4 22661376 [A/G] rs7682899 4 22665990 [A/G] rs2581966 4 22671199 [A/G] rs12501294 4 22683706 [A/G] rs6856346 4 22685868 [A/C] rs2009731 4 22687741 [T/G] rs12506103 4 22689850 [T/C] rs10028144 4 22691505 [A/G] rs7682224 4 22693754 [T/C] rs10004988 4 22696560 [T/C] NR_102355,NR_102356,NM_001128432,NM_020973 GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent rs16872974 4 22696570 [T/C] NR_102355,NR_102356,NM_001128432,NM_020973 GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent rs9991992 4 22699639 [A/G] NR_102355,NR_102356,NM_001128432,NM_020973 GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent rs7442608 4 22711069 [T/C] NR_102355,NR_102356,NM_001128432,NM_020973 GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent rs17539365 4 22714805 [A/G] NR_102355,NR_102356,NM_001128432,NM_020973 GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent rs16873068 4 22715030 [T/C] NR_102355,NR_102356,NM_001128432,NM_020973 GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent rs1963996 4 22715639 [A/G] NR_102355,NR_102356,NM_001128432,NM_020973 GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent rs1485829 4 22717410 [T/G] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs11935750 4 22720917 [T/C] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs10013725 4 22730383 [T/G] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs7682149 4 22734612 [T/C] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs7688368 4 22737356 [A/C] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs10007404 4 22737485 [A/G] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs17540321 4 22757756 [A/G] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs4697335 4 22758659 [A/G] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs16873132 4 22762166 [A/G] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs1385760 4 22770299 [A/C] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs4103518 4 22774617 [T/C] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs10000431 4 22786034 [T/C] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs6854336 4 22793164 [A/G] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs358255 4 22793514 [A/G] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs183084 4 22793528 [A/G] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs358254 4 22794601 [A/G] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs370843 4 22803174 [T/C] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs358238 4 22812879 [A/G] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs358233 4 22819747 [A/G] NR_102355,NR_102356,NM_001128432,NM_020973,NR_102357,NM_001277225 GBA3,GBA3,GBA3,GBA3,GBA3,GBA3 Silent,Silent,Silent,Silent,Silent,Silent rs3099557 4 22824021 [A/G] rs430976 4 22832447 [T/C] rs439863 4 22832682 [A/G] rs418932 4 22834211 [T/C] rs412218 4 22843458 [A/C] rs403543 4 22844392 [T/C] rs11946006 4 22850202 [A/G] rs10010827 4 22850930 [A/G] rs358224 4 22860785 [A/G] rs921096 4 22871367 [A/G] rs6840245 4 22878904 [A/G] rs16873200 4 22887214 [A/C] rs718137 4 22901347 [A/C] rs4697350 4 22915626 [T/C] rs4697351 4 22918094 [A/C] rs2323700 4 22934689 [T/C] rs2044512 4 22937281 [A/G] rs16873221 4 22940211 [T/C] rs6448180 4 22946063 [A/G] rs13113121 4 22962472 [T/C] rs13132256 4 22979347 [A/G] rs10213115 4 22994533 [A/G] rs10938926 4 23002014 [A/G] rs4697359 4 23009296 [A/G] rs4391017 4 23015784 [T/C] rs7664442 4 23018704 [A/G] rs4697365 4 23032220 [A/G] rs35570804 4 23038516 [A/C] rs7660606 4 23040791 [A/G] rs7667946 4 23063024 [T/C] rs4235300 4 23067145 [T/G] rs11933588 4 23078639 [A/G] rs11944694 4 23085015 [A/G] rs4607200 4 23129245 [T/C] rs11733138 4 23160661 [A/G] rs11932311 4 23165631 [T/C] rs7676830 4 23169854 [T/C] rs4498120 4 23173926 [A/G] rs10805240 4 23175107 [T/C] rs6830403 4 23194506 [T/C] rs7697052 4 23205306 [A/G] rs13127424 4 23209159 [A/G] rs7668474 4 23220263 [A/G] rs10517006 4 23230869 [T/C] rs20414 4 23235331 [A/C] rs4697372 4 23244074 [T/C] rs16873390 4 23251514 [T/G] rs10938932 4 23266728 [T/C] rs16873417 4 23267131 [T/C] rs10020391 4 23272693 [T/C] rs7658635 4 23288742 [T/C] rs10050029 4 23289721 [A/G] rs12503311 4 23293043 [T/C] rs10938939 4 23296159 [T/C] rs10517009 4 23301509 [T/C] rs12507992 4 23307693 [T/C] rs2036713 4 23307920 [A/C] rs16873489 4 23313796 [T/C] rs2175069 4 23317124 [A/G] rs16873495 4 23320940 [A/C] rs11731411 4 23323428 [T/C] rs1858113 4 23324095 [A/C] rs882348 4 23325040 [A/G] rs1912031 4 23329039 [A/G] rs10517011 4 23333141 [A/G] rs2940777 4 23338785 [T/C] rs11728319 4 23340149 [A/G] rs6448201 4 23340766 [A/G] rs1509247 4 23343798 [T/C] rs1396669 4 23345454 [T/G] rs13151220 4 23346349 [T/G] rs2940776 4 23348610 [A/G] rs12509827 4 23350299 [A/G] rs10005577 4 23351305 [A/G] rs7690639 4 23351883 [T/C] rs10938942 4 23352821 [T/C] rs7682902 4 23354371 [T/C] rs7666498 4 23356724 [T/C] rs1876758 4 23366950 [T/C] rs11930868 4 23371874 [T/G] rs169998 4 23386583 [A/G] rs215478 4 23387315 [T/C] rs215475 4 23388399 [A/G] rs976892 4 23390149 [A/G] rs17539073 4 23390161 [A/G] rs4697034 4 23394710 [A/G] rs2159518 4 23416412 [A/G] rs215410 4 23424060 [T/G] rs215408 4 23424293 [T/C] rs6831885 4 23425414 [T/C] rs10009679 4 23428006 [T/C] rs1605813 4 23430768 [A/G] rs215446 4 23438665 [T/C] rs6817487 4 23451237 [T/C] rs215428 4 23451900 [A/G] rs17613288 4 23454910 [T/C] rs4697389 4 23456531 [T/C] rs4697390 4 23456789 [T/C] rs13129559 4 23462730 [T/C] rs1304559 4 23466369 [T/C] rs723394 4 23473748 [A/G] rs723393 4 23473797 [A/G] rs12331728 4 23474365 [A/G] rs6829223 4 23474539 [A/G] rs10010445 4 23475851 [A/G] rs887471 4 23476755 [T/C] rs12498626 4 23477482 [A/G] rs11728280 4 23478842 [T/C] rs16873729 4 23480613 [T/C] rs17613848 4 23485012 [A/G] rs6857002 4 23485264 [T/G] rs6831833 4 23485419 [T/G] rs756516 4 23487104 [A/G] rs12505641 4 23488892 [A/G] rs4317189 4 23495538 [T/C] rs216108 4 23503444 [T/G] rs1155194 4 23516635 [A/G] rs17554625 4 23520711 [T/C] rs16873798 4 23523429 [A/C] rs1003561 4 23532789 [A/G] rs10517015 4 23539244 [A/G] rs2323996 4 23546394 [T/C] rs10021542 4 23555237 [A/G] rs10517018 4 23560044 [T/C] rs950950 4 23561662 [T/C] rs4331766 4 23563103 [T/C] rs10017437 4 23566334 [T/C] rs13103252 4 23572152 [A/G] rs11727130 4 23574876 [A/G] rs10009448 4 23575883 [A/G] rs9884254 4 23579235 [A/G] rs10470807 4 23581156 [T/C] rs10027997 4 23587465 [A/G] rs1397829 4 23587996 [A/G] rs4697039 4 23591442 [A/G] rs17632146 4 23600766 [T/G] rs6810541 4 23607172 [T/G] rs7693965 4 23613573 [A/C] rs13121107 4 23615048 [A/G] rs12108313 4 23616145 [A/G] rs13121520 4 23622531 [A/G] rs10001239 4 23626018 [T/C] rs6845167 4 23631034 [T/C] rs868356 4 23631474 [A/G] rs13118539 4 23631863 [A/G] rs16873952 4 23632143 [A/G] rs13123614 4 23638099 [A/G] rs1565535 4 23642370 [T/G] rs2035827 4 23663235 [A/G] rs306050 4 23669223 [A/C] rs4697408 4 23680862 [T/C] rs10008808 4 23683303 [A/G] rs2054996 4 23686819 [T/C] rs11736033 4 23688573 [A/G] rs1491377 4 23702558 [A/G] rs10938956 4 23705256 [A/G] rs1491393 4 23708557 [T/C] rs13434906 4 23712340 [T/C] rs2130926 4 23712830 [T/C] rs1021400 4 23714895 [A/G] rs10010697 4 23719003 [A/G] rs17572286 4 23724215 [A/G] rs16874043 4 23730887 [T/C] rs10517023 4 23732218 [A/C] rs1491389 4 23734719 [A/G] rs1352802 4 23736348 [A/G] rs13107733 4 23736573 [A/G] rs7656180 4 23738906 [T/C] rs1027228 4 23739736 [A/G] rs1565537 4 23739796 [A/G] rs16874072 4 23743450 [T/C] rs963209 4 23744268 [T/C] rs13142156 4 23746582 [T/C] rs1491384 4 23746704 [A/G] rs974083 4 23759262 [A/G] rs13122003 4 23759328 [T/C] rs4697418 4 23759713 [T/C] rs1491379 4 23759757 [T/C] rs16874121 4 23767480 [A/C] rs885395 4 23770218 [A/G] rs2932978 4 23781649 [A/G] rs2970882 4 23788341 [T/C] rs9790699 4 23792768 [T/C] rs2279525 4 23794252 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3774923 4 23795064 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6821591 4 23797000 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3821952 4 23797733 [A/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs768695 4 23798818 [A/G] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12650562 4 23801187 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2932965 4 23805486 [A/G] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1873532 4 23806778 [A/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3755863 4 23815522 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A EXON Silent,Synonymous_T401T,Silent,Synonymous_T528T,Silent,Silent,Synonymous_T401T,Synonymous_T533T,Silent,Synonymous_T533T,Silent,Synonymous_T533T,Synonymous_T516T,Silent rs8192678 4 23815662 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A EXON Silent,Missense_G355S,Silent,Missense_G482S,Silent,Silent,Missense_G355S,Missense_G487S,Silent,Missense_G487S,Silent,Missense_G487S,Missense_G470S,Silent rs2970847 4 23815924 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A EXON Silent,Synonymous_T267T,Silent,Synonymous_T394T,Silent,Silent,Synonymous_T267T,Synonymous_T399T,Silent,Synonymous_T399T,Silent,Synonymous_T399T,Synonymous_T382T,Silent rs2970848 4 23817027 [A/G] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16874180 4 23818762 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2932971 4 23818884 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2932976 4 23822328 [A/G] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2970853 4 23823519 [A/G] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3774909 4 23828708 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3774908 4 23828934 [A/G] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1388332 4 23829314 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3774906 4 23832084 [T/G] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6448226 4 23836653 [A/G] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10938964 4 23840088 [A/G] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7665116 4 23853011 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7437482 4 23855974 [A/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6829564 4 23863631 [A/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4452416 4 23863873 [T/G] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4235308 4 23864412 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4697426 4 23864809 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7656250 4 23866016 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10213440 4 23866339 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9996943 4 23871021 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6838600 4 23875311 [A/G] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4361373 4 23875675 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17637318 4 23880985 [T/C] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16874276 4 23881977 [A/G] NR_148983,NM_001330753,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4469064 4 23883796 [A/G] NR_148983,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3796407 4 23884711 [A/G] NR_148983,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981,NM_001354828 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16874284 4 23885495 [T/C] NR_148983,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981,NM_001354828 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12500214 4 23885568 [A/G] NR_148983,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981,NM_001354828 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2946385 4 23886323 [T/G] NR_148983,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981,NM_001354828 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Synonymous_R96R rs2970872 4 23889813 [A/G] NR_148983,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981,NM_001354828 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3774902 4 23890782 [A/G] NR_148983,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981,NM_001354828 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3774901 4 23891094 [T/C] NR_148983,NR_148987,NM_013261,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NR_148984,NM_001330751,NM_001330752,NR_148981,NM_001354828 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2970870 4 23893017 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1878949 4 23895413 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7657071 4 23896474 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2970863 4 23897796 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4568225 4 23898430 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2946390 4 23900959 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2970860 4 23901275 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10030083 4 23901422 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2946392 4 23903867 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17576576 4 23907727 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2946394 4 23907928 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13108219 4 23908890 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs957615 4 23909565 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs957616 4 23909599 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2946399 4 23913579 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2946403 4 23921453 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2946405 4 23925233 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6817420 4 23927720 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4697428 4 23935053 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4697429 4 23937074 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10017711 4 23955370 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10517026 4 23957254 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10029638 4 23958805 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10938973 4 23959089 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9291455 4 23962031 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13111174 4 23962061 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10020457 4 23962961 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2324237 4 23966042 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10517031 4 23968295 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16874416 4 23969013 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10470808 4 23972257 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2324233 4 23972751 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1316862 4 23976060 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1316861 4 23977778 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1714638 4 23986967 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs609893 4 23990989 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16874486 4 23991100 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6833157 4 23994155 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16874509 4 23996375 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs597082 4 23996637 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs637282 4 23998787 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10026136 4 24000480 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs668672 4 24001226 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6858449 4 24002981 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16874560 4 24006777 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16874564 4 24009437 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs609501 4 24010844 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7672552 4 24011608 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13142815 4 24014210 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2191598 4 24016473 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1990411 4 24018589 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs694917 4 24026356 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs648674 4 24026481 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs630902 4 24028621 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6858568 4 24030761 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2109597 4 24031726 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10008679 4 24034708 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs620157 4 24035342 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs618283 4 24035754 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10025406 4 24040555 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs650356 4 24041100 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6820543 4 24041241 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4697435 4 24047613 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs625365 4 24048711 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs672014 4 24053122 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs627086 4 24054904 [T/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs626610 4 24055017 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs584374 4 24057548 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs621820 4 24059720 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs647536 4 24060940 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16874916 4 24064404 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16874925 4 24067146 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3815420 4 24069770 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2215488 4 24072063 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10938978 4 24074065 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6846769 4 24076706 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16874990 4 24092877 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17188642 4 24105609 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875020 4 24106336 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875028 4 24111301 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6848087 4 24114572 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13109143 4 24115074 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7680610 4 24118165 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875049 4 24119282 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875053 4 24120388 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10489098 4 24125887 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2215492 4 24128287 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12644722 4 24130517 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs929530 4 24133750 [T/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12512863 4 24134431 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7672932 4 24134520 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875100 4 24135578 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7663527 4 24138139 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6841821 4 24141403 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12639872 4 24143686 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1705098 4 24144512 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875151 4 24147509 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13110084 4 24150414 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1267016 4 24151604 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1267012 4 24154002 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17794487 4 24154725 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10213261 4 24156429 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2535559 4 24156537 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10517034 4 24171888 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6839666 4 24176596 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875239 4 24178227 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875243 4 24180666 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875269 4 24187873 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7676251 4 24190844 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12108491 4 24192793 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6822382 4 24193409 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6848086 4 24195161 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1877089 4 24195219 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1473049 4 24197054 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12647637 4 24198653 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1397490 4 24199845 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13131294 4 24205824 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1995917 4 24207765 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9684046 4 24212477 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6837980 4 24213123 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4697051 4 24215638 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4697052 4 24223553 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6820131 4 24225918 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10016733 4 24229043 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6448251 4 24230323 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6813754 4 24232043 [T/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10938983 4 24232169 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4235311 4 24233053 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4235312 4 24233227 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17641468 4 24234074 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1510784 4 24235281 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10016565 4 24237854 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7662477 4 24238470 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6448252 4 24238868 [T/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10023214 4 24240273 [T/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2324421 4 24241504 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7666134 4 24242223 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875393 4 24242446 [T/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7673666 4 24245365 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs938070 4 24245579 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7679088 4 24246136 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7663508 4 24246892 [T/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12642909 4 24253157 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6448254 4 24255842 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7688742 4 24256292 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7356453 4 24256496 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1995919 4 24259055 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17581643 4 24262089 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1969192 4 24263196 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6852227 4 24263853 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10938987 4 24264014 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875458 4 24264580 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17581877 4 24264901 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17648420 4 24267149 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875481 4 24267644 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17648562 4 24268594 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1511358 4 24268934 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4697446 4 24269622 [T/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11945373 4 24271684 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11931856 4 24271794 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4458444 4 24272279 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10031996 4 24272929 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4697447 4 24275114 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7685185 4 24276706 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17582609 4 24277125 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7659588 4 24280482 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6448255 4 24283000 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12646616 4 24298140 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17582833 4 24302081 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1849098 4 24302785 [T/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1464008 4 24303151 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1949112 4 24305034 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7685773 4 24307070 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875528 4 24308079 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6815672 4 24310076 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10005021 4 24310512 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2063409 4 24315694 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6448258 4 24316984 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9998315 4 24317057 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6827997 4 24317449 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9994454 4 24322900 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9685879 4 24324261 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16835 4 24335226 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13143233 4 24336391 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11938023 4 24340511 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17649407 4 24342273 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4529036 4 24353666 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10024907 4 24358657 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10002552 4 24358882 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17650027 4 24364497 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10805250 4 24368837 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10007635 4 24369452 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6848313 4 24373046 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10018759 4 24377777 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3857105 4 24378477 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3857106 4 24379666 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17591101 4 24384208 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875599 4 24392437 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4697455 4 24393041 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11721883 4 24397676 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6854638 4 24403899 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4443265 4 24410336 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4406005 4 24410439 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7680809 4 24413937 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6858097 4 24415276 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6835454 4 24415312 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs744790 4 24416173 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11938561 4 24422187 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7690462 4 24424154 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4697458 4 24429852 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17651313 4 24433341 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875639 4 24435780 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875643 4 24436905 [T/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs5015586 4 24438499 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6817993 4 24438686 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11723961 4 24439865 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16875658 4 24443965 [A/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6823107 4 24444785 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17651758 4 24448584 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17592374 4 24448620 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10027557 4 24451107 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10018808 4 24451810 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10025642 4 24454502 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10026526 4 24455932 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13112452 4 24456779 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13435868 4 24462075 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11737023 4 24467089 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3811738 4 24470143 [A/G] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3828483 4 24470847 [T/C] NR_148983,NR_148987,NR_148982,NR_148986,NM_001354826,NM_001354825,NR_148985,NM_001354827,NM_001330751,NM_001330752,NR_148981 PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A,PPARGC1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12506649 4 24480956 [A/C] rs4697062 4 24483311 [T/C] rs16875687 4 24484868 [A/G] rs16875707 4 24488420 [A/G] rs7656078 4 24489441 [T/G] rs34850839 4 24493051 [A/G] rs1567045 4 24512590 [T/C] rs12651262 4 24514957 [A/C] rs6448278 4 24521431 [T/C] rs10517052 4 24526581 [T/C] rs16875742 4 24528892 [T/C] rs3828558 4 24534687 [T/C] NM_001358 DHX15 Silent rs3828557 4 24540950 [A/G] NM_001358 DHX15 Silent rs2048026 4 24546752 [T/C] NM_001358 DHX15 Silent rs7690565 4 24548678 [T/G] NM_001358 DHX15 Silent rs12509760 4 24554084 [A/G] NM_001358 DHX15 Silent rs13115594 4 24570155 [T/C] NM_001358 DHX15 Silent rs11940872 4 24573228 [T/C] NM_001358 DHX15 Silent rs6841898 4 24578097 [T/C] NM_001358 DHX15 EXON Synonymous_T92T rs6812715 4 24584445 [T/C] NM_001358 DHX15 Silent rs10939001 4 24593495 [T/C] rs9994148 4 24593935 [A/G] rs4399976 4 24604480 [T/C] rs3857113 4 24604616 [T/C] rs13113294 4 24605273 [A/G] rs10033408 4 24610039 [A/G] rs6825842 4 24618440 [A/G] rs12640588 4 24624177 [T/C] rs13137535 4 24624240 [T/C] rs1395221 4 24626903 [T/G] rs12501699 4 24646772 [T/G] rs7695254 4 24650004 [A/C] rs4312745 4 24651750 [T/C] rs10939004 4 24652142 [T/C] rs7693909 4 24653384 [T/C] rs4295245 4 24672521 [A/G] rs12507254 4 24673420 [T/G] rs4499689 4 24676205 [A/G] rs4351004 4 24676608 [A/G] rs13101306 4 24686179 [A/G] rs11736386 4 24688574 [T/C] rs16875929 4 24691463 [A/G] rs9994680 4 24696151 [T/C] rs6826722 4 24706382 [A/G] rs2080014 4 24710623 [T/C] rs10013569 4 24710866 [A/G] rs7665329 4 24721636 [T/C] rs980797 4 24723481 [A/G] rs4697070 4 24725521 [A/G] rs7666030 4 24728480 [A/G] rs6833151 4 24734831 [A/G] rs1476880 4 24736258 [T/G] rs12500612 4 24740958 [T/G] rs10012911 4 24742042 [T/G] rs6851578 4 24750063 [T/C] rs6448303 4 24750388 [T/C] rs758951 4 24754107 [A/C] rs13104450 4 24760492 [T/G] rs1014262 4 24762301 [T/C] rs7435399 4 24765819 [T/C] rs17622586 4 24773146 [T/C] rs13134000 4 24773476 [A/G] rs699471 4 24776311 [T/G] rs12501287 4 24776982 [T/C] rs13138705 4 24779506 [T/C] rs800421 4 24785911 [T/C] rs800423 4 24786505 [T/C] rs13434451 4 24786904 [A/G] rs12649653 4 24791146 [A/G] rs6849330 4 24792175 [T/G] rs2284659 4 24794797 [T/G] rs17883092 4 24796119 [A/G] rs17879149 4 24796307 [T/C] rs17878927 4 24796553 [A/G] rs8192287 4 24796568 [T/G] rs699473 4 24796803 [T/C] rs7688692 4 24796977 [T/C] rs17880193 4 24797442 [T/C] NM_003102 SOD3 Silent rs17883306 4 24797653 [T/C] NM_003102 SOD3 Silent rs17883045 4 24797762 [T/C] NM_003102 SOD3 Silent rs17882807 4 24797767 [T/G] NM_003102 SOD3 Silent rs17879917 4 24799398 [T/C] NM_003102 SOD3 Silent rs17880362 4 24799701 [T/C] NM_003102 SOD3 Silent rs17882785 4 24799827 [T/G] NM_003102 SOD3 Silent rs17878878 4 24800435 [A/G] NM_003102 SOD3 Silent rs11544040 4 24801236 [A/G] NM_003102 SOD3 EXON Synonymous_S31S rs800447 4 24802205 [A/C] NM_003102 SOD3 EXON Silent rs17552548 4 24804722 [A/G] rs758946 4 24807287 [T/C] rs1019229 4 24809884 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 EXON Silent,Silent,Silent,Silent rs800456 4 24828799 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs800457 4 24829427 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs12510565 4 24831203 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs16876184 4 24831450 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs12511680 4 24832309 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs16876189 4 24832724 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs6838713 4 24836416 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs16876194 4 24836619 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 EXON Synonymous_Q257Q,Synonymous_Q257Q,Synonymous_Q202Q,Synonymous_Q257Q rs17553672 4 24839564 [T/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs11933544 4 24841692 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs12510049 4 24842936 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs800460 4 24846501 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs6854022 4 24855955 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs6812368 4 24856827 [T/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs800464 4 24856909 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs17625018 4 24860242 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs800478 4 24860527 [A/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs16876269 4 24870337 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs800379 4 24871204 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs800383 4 24871999 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs13131918 4 24873604 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs941265 4 24881852 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs6820765 4 24882927 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs10517056 4 24885284 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs1527354 4 24885567 [T/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs1527353 4 24885755 [T/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs4697489 4 24886099 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs16876331 4 24891384 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs16876333 4 24892761 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs10939012 4 24897032 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs4697493 4 24899586 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs9993370 4 24900112 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs2695227 4 24901395 [T/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs4053966 4 24901466 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs4697075 4 24902583 [A/C] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs4697076 4 24908601 [A/G] NM_001330643,NM_173463,NM_001330644,NM_001130726 CCDC149,CCDC149,CCDC149,CCDC149 Silent,Silent,Silent,Silent rs11721701 4 24924432 [T/C] NM_173463 CCDC149 Silent rs7680589 4 24924497 [T/C] NM_173463 CCDC149 Silent rs3846336 4 24931019 [A/G] NM_173463 CCDC149 Silent rs1527359 4 24932206 [T/G] NM_173463 CCDC149 Silent rs11931422 4 24936925 [T/C] NM_173463 CCDC149 Silent rs10008999 4 24938446 [A/G] NM_173463 CCDC149 Silent rs12645335 4 24939037 [A/G] NM_173463 CCDC149 Silent rs13105803 4 24940002 [A/G] NM_173463 CCDC149 Silent rs2167955 4 24949675 [T/G] NM_173463 CCDC149 Silent rs4235320 4 24955907 [A/G] NM_173463 CCDC149 Silent rs4697503 4 24956062 [A/G] NM_173463 CCDC149 Silent rs1453815 4 24957653 [T/C] NM_173463 CCDC149 Silent rs13126958 4 24978429 [A/G] NM_173463 CCDC149 Silent rs764496 4 24981812 [A/G] NM_173463 CCDC149 EXON Silent rs7668800 4 24983923 [A/G] rs13130781 4 24991254 [A/G] rs4317191 4 24991618 [T/C] rs4697082 4 24992827 [T/C] rs2098300 4 24994457 [A/G] rs13135230 4 24996698 [A/G] rs6849078 4 24998080 [A/G] rs17406878 4 24999299 [T/G] rs16876537 4 24999316 [A/G] rs4697519 4 25000053 [A/G] rs7659172 4 25000555 [A/G] NM_018176 LGI2 EXON Silent rs6822065 4 25001339 [A/G] NM_018176 LGI2 EXON Silent rs7670138 4 25001685 [A/C] NM_018176 LGI2 EXON Silent rs6853990 4 25002119 [T/G] NM_018176 LGI2 EXON Silent rs8235 4 25003503 [A/G] NM_018176 LGI2 EXON Silent rs6841999 4 25004004 [A/G] NM_018176 LGI2 EXON Silent rs3796786 4 25004757 [T/G] NM_018176 LGI2 EXON Silent rs3796787 4 25004778 [A/C] NM_018176 LGI2 EXON Silent rs2232030 4 25004971 [T/C] NM_018176 LGI2 EXON Silent rs2232029 4 25005023 [T/C] NM_018176 LGI2 EXON Silent rs2232027 4 25005356 [T/C] NM_018176 LGI2 EXON Missense_Q452R rs2232025 4 25005454 [A/G] NM_018176 LGI2 EXON Synonymous_D419D rs4235326 4 25009491 [T/C] NM_018176 LGI2 Silent rs11733058 4 25011001 [T/C] NM_018176 LGI2 Silent rs1000946 4 25013576 [A/G] NM_018176 LGI2 Silent rs6826019 4 25014191 [T/G] NM_018176 LGI2 Silent rs2110453 4 25014793 [A/G] NM_018176 LGI2 Silent rs10488953 4 25017735 [A/C] NM_018176 LGI2 Silent rs4697525 4 25018625 [T/C] NM_018176 LGI2 Silent rs2324642 4 25019263 [T/C] NM_018176 LGI2 Silent rs10022509 4 25020194 [A/G] NM_018176 LGI2 Silent rs6448323 4 25022408 [T/C] NM_018176 LGI2 Silent rs4560399 4 25023893 [T/C] NM_018176 LGI2 Silent rs16876650 4 25024935 [T/C] NM_018176 LGI2 Silent rs6843764 4 25025389 [T/C] NM_018176 LGI2 Silent rs4428268 4 25028158 [T/G] NM_018176 LGI2 Silent rs757637 4 25029817 [A/G] NM_018176 LGI2 Silent rs736831 4 25033008 [A/G] rs10939032 4 25036142 [T/C] rs7676843 4 25036320 [T/C] rs4235328 4 25040676 [A/G] rs2324648 4 25041054 [T/C] rs10488952 4 25041068 [A/C] rs2324649 4 25041513 [T/G] rs16876673 4 25041606 [A/C] rs2192444 4 25047177 [A/G] rs13124493 4 25048536 [A/G] rs10013086 4 25052099 [A/G] rs11931069 4 25053498 [A/C] rs6856359 4 25056765 [A/G] rs759245 4 25058232 [A/G] rs6448329 4 25060758 [T/C] rs4533756 4 25062976 [A/G] rs7654693 4 25066309 [T/G] rs12502737 4 25066802 [A/C] rs6817894 4 25067218 [T/C] rs6841005 4 25067377 [T/C] rs4697534 4 25067465 [T/C] rs13116533 4 25068062 [T/C] rs2098302 4 25068446 [A/C] rs2324654 4 25072651 [T/C] rs10488951 4 25072803 [A/G] rs7693334 4 25081118 [A/G] rs16876761 4 25083127 [T/C] rs7682064 4 25087708 [T/C] rs6846989 4 25088919 [T/C] rs16876788 4 25090812 [A/G] rs16876811 4 25102070 [A/G] rs759243 4 25107115 [A/G] rs16876855 4 25113048 [T/C] rs16876859 4 25114103 [T/G] rs10939038 4 25114664 [T/C] rs10018563 4 25119575 [T/C] rs9998044 4 25123344 [T/C] NM_016955 SEPSECS EXON Silent rs17408685 4 25127309 [T/C] NM_016955 SEPSECS Silent rs16876882 4 25130283 [T/C] NM_016955 SEPSECS Silent rs10213282 4 25135095 [T/C] NM_016955 SEPSECS Silent rs2302565 4 25146307 [A/G] NM_016955 SEPSECS Silent rs3796795 4 25148136 [T/G] NM_016955 SEPSECS Silent rs11937742 4 25163672 [A/G] NR_037934 SEPSECS-AS1 Silent rs10939039 4 25165833 [A/G] NR_037934 SEPSECS-AS1 Silent rs13139513 4 25168417 [A/G] NR_037934 SEPSECS-AS1 Silent rs6845806 4 25168491 [A/G] NR_037934 SEPSECS-AS1 Silent rs6838393 4 25174251 [A/G] NR_037934 SEPSECS-AS1 Silent rs10017010 4 25188718 [A/G] NR_037934 SEPSECS-AS1 Silent rs1909475 4 25200584 [T/C] rs12502384 4 25203905 [A/G] rs12505283 4 25204724 [A/C] rs16876951 4 25208160 [T/C] rs17602779 4 25223799 [A/C] rs10007349 4 25226538 [A/G] rs7654358 4 25227917 [A/G] rs313548 4 25237391 [A/G] NR_144633,NM_018323 PI4K2B,PI4K2B Silent,Silent rs35236315 4 25240249 [A/G] NR_144633,NM_018323 PI4K2B,PI4K2B Silent,Silent rs313567 4 25253995 [T/C] NR_144633,NM_018323 PI4K2B,PI4K2B EXON Silent,Synonymous_A107A rs10006479 4 25255841 [T/C] NR_144633,NM_018323 PI4K2B,PI4K2B Silent,Silent rs13121926 4 25266119 [A/G] NR_144633,NM_018323 PI4K2B,PI4K2B Silent,Silent rs313543 4 25268962 [A/G] NR_144633,NM_018323 PI4K2B,PI4K2B Silent,Silent rs3115232 4 25270011 [A/G] NR_144633,NM_018323 PI4K2B,PI4K2B Silent,Silent rs16876963 4 25272880 [A/G] NR_144633,NM_018323 PI4K2B,PI4K2B Silent,Silent rs7696265 4 25273241 [T/C] NR_144633,NM_018323 PI4K2B,PI4K2B Silent,Silent rs10014603 4 25274572 [T/C] NR_144633,NM_018323 PI4K2B,PI4K2B Silent,Silent rs16876969 4 25275648 [T/C] NR_144633,NM_018323 PI4K2B,PI4K2B Silent,Silent rs3796780 4 25278988 [T/C] NR_144633,NM_018323 PI4K2B,PI4K2B EXON Silent,Silent rs6834255 4 25279320 [A/G] NR_144633,NM_018323 PI4K2B,PI4K2B EXON Silent,Silent rs12505006 4 25281948 [T/C] rs4370127 4 25282410 [T/C] rs12649921 4 25285913 [A/G] rs6448346 4 25294239 [T/G] rs13121078 4 25296004 [T/C] rs7672293 4 25296348 [A/C] rs13133104 4 25309815 [A/G] rs11726511 4 25310060 [A/G] rs316807 4 25310351 [T/C] rs16876992 4 25310628 [A/G] rs1533131 4 25312242 [A/G] rs1533132 4 25312357 [A/G] rs16877005 4 25313994 [A/G] rs12508686 4 25316815 [T/C] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs1553876 4 25317277 [A/G] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs4697567 4 25318984 [A/G] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs10939051 4 25319698 [T/C] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs10031354 4 25320465 [T/C] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs1963656 4 25324742 [T/C] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs12642624 4 25324899 [A/G] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs13128106 4 25325264 [T/C] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs2667295 4 25327288 [T/G] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs1511411 4 25327926 [A/G] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs316783 4 25342463 [A/C] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs16877042 4 25344591 [T/C] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs13114588 4 25347771 [A/G] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs2875425 4 25349921 [A/G] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs10009504 4 25352640 [A/G] NM_001318148,NM_024936 ZCCHC4,ZCCHC4 Silent,Silent rs316776 4 25357164 [T/C] NM_024936 ZCCHC4 Silent rs184360 4 25362101 [A/G] NM_024936 ZCCHC4 Silent rs315674 4 25367546 [T/C] NM_024936 ZCCHC4 Silent rs315688 4 25371815 [A/G] NM_024936 ZCCHC4 EXON Silent rs2324761 4 25382783 [T/C] NM_001286756,NM_013367 ANAPC4,ANAPC4 Silent,Silent rs10027814 4 25386559 [A/G] NM_001286756,NM_013367 ANAPC4,ANAPC4 Silent,Silent rs186408 4 25391584 [A/G] NM_001286756,NM_013367 ANAPC4,ANAPC4 Silent,Silent rs315669 4 25394785 [A/C] NM_001286756,NM_013367 ANAPC4,ANAPC4 Silent,Silent rs13152467 4 25397459 [T/G] NM_001286756,NM_013367 ANAPC4,ANAPC4 Silent,Silent rs10032586 4 25400468 [A/G] NM_001286756,NM_013367 ANAPC4,ANAPC4 Silent,Silent rs13109196 4 25401863 [A/G] NM_001286756,NM_013367 ANAPC4,ANAPC4 Silent,Silent rs12506959 4 25402066 [T/C] NM_001286756,NM_013367 ANAPC4,ANAPC4 Silent,Silent rs316770 4 25405998 [T/C] NM_001286756,NM_013367 ANAPC4,ANAPC4 Silent,Silent rs3756202 4 25407356 [A/G] NM_001286756,NM_013367 ANAPC4,ANAPC4 Silent,Silent rs1993602 4 25415106 [T/C] NM_001286756,NM_013367 ANAPC4,ANAPC4 Silent,Silent rs3816587 4 25417244 [T/C] NM_001286756,NM_013367 ANAPC4,ANAPC4 Silent,Silent rs10517073 4 25417371 [A/G] NM_001286756,NM_013367 ANAPC4,ANAPC4 Silent,Silent rs9174 4 25419283 [T/C] NM_001286756,NM_013367 ANAPC4,ANAPC4 EXON Synonymous_F708F,Synonymous_F707F rs3214036 4 25419908 [T/G] NM_001286756,NM_013367 ANAPC4,ANAPC4 EXON Synonymous_S778S,Synonymous_S777S rs4697095 4 25427554 [T/C] rs1996180 4 25429854 [A/C] rs13131313 4 25432828 [A/G] rs11934787 4 25438001 [T/C] rs6837837 4 25438518 [A/C] rs6852016 4 25440525 [A/G] rs7698526 4 25440832 [T/C] rs10008104 4 25444762 [A/G] rs6448356 4 25446100 [A/C] rs7690450 4 25452180 [A/C] rs922054 4 25455404 [T/G] rs1996182 4 25457501 [A/G] rs1996183 4 25457661 [A/C] rs12507905 4 25464527 [T/C] rs3851436 4 25464878 [A/G] rs13114364 4 25465790 [T/C] rs13116199 4 25466614 [T/C] rs1399240 4 25467149 [A/G] rs12650434 4 25475192 [A/G] rs959018 4 25475510 [T/C] rs4697098 4 25486335 [A/C] rs6851586 4 25500479 [A/G] rs989263 4 25502383 [T/C] rs10050090 4 25504060 [T/C] rs6854268 4 25505735 [A/C] rs6831932 4 25505932 [T/C] rs6448365 4 25507698 [A/G] rs4053860 4 25514402 [A/G] rs6448367 4 25531234 [A/G] rs4697584 4 25533554 [A/C] NR_134641 LOC101929161 Silent rs10018150 4 25536386 [A/G] NR_134641 LOC101929161 Silent rs12331861 4 25542206 [T/C] NR_134641 LOC101929161 Silent rs871476 4 25543152 [T/C] NR_134641 LOC101929161 Silent rs2176838 4 25546127 [T/C] NR_134641 LOC101929161 Silent rs9991078 4 25554332 [T/C] NR_134641 LOC101929161 Silent rs10939060 4 25556172 [T/C] NR_134641 LOC101929161 Silent rs7686265 4 25557047 [T/C] NR_134641 LOC101929161 Silent rs11937512 4 25558594 [A/G] NR_134641 LOC101929161 Silent rs1980239 4 25562241 [T/C] NR_134641 LOC101929161 Silent rs6830401 4 25562386 [T/C] NR_134641 LOC101929161 Silent rs6813987 4 25565070 [A/C] NR_134641 LOC101929161 Silent rs16877245 4 25569061 [A/G] NR_134641 LOC101929161 Silent rs16877251 4 25571044 [A/G] rs7689639 4 25575537 [A/G] rs13147366 4 25576330 [T/C] rs10013819 4 25577184 [A/G] rs6830679 4 25583481 [T/C] rs2308974 4 25584201 [A/G] rs4697106 4 25587743 [T/G] rs6448380 4 25589180 [T/C] rs6448381 4 25591895 [T/C] rs16877296 4 25592650 [A/G] rs10939067 4 25594437 [A/G] rs7664681 4 25594556 [T/C] rs939356 4 25615723 [A/C] rs9992129 4 25616103 [T/G] rs6821985 4 25620658 [A/G] rs7671379 4 25625150 [T/C] rs12499526 4 25627026 [T/G] rs12504139 4 25628002 [A/G] rs7676077 4 25629255 [T/C] rs10517077 4 25638736 [T/G] rs4327471 4 25641870 [T/G] rs4580639 4 25645165 [T/C] rs6448388 4 25654566 [A/G] rs11721800 4 25656404 [T/C] rs3815464 4 25671043 [T/C] NM_006424,NM_001177998,NM_001177999 SLC34A2,SLC34A2,SLC34A2 Silent,Silent,Silent rs3796777 4 25674194 [T/C] NM_006424,NM_001177998,NM_001177999 SLC34A2,SLC34A2,SLC34A2 Silent,Silent,Silent rs2240997 4 25675125 [A/G] NM_006424,NM_001177998,NM_001177999 SLC34A2,SLC34A2,SLC34A2 Silent,Silent,Silent rs2240998 4 25675203 [A/G] NM_006424,NM_001177998,NM_001177999 SLC34A2,SLC34A2,SLC34A2 Silent,Silent,Silent rs12505556 4 25676982 [A/C] NM_006424,NM_001177998,NM_001177999 SLC34A2,SLC34A2,SLC34A2 Silent,Silent,Silent rs3733545 4 25678396 [T/G] NM_006424,NM_001177998,NM_001177999 SLC34A2,SLC34A2,SLC34A2 EXON Silent,Silent,Silent rs4374611 4 25678659 [A/G] NM_006424,NM_001177998,NM_001177999 SLC34A2,SLC34A2,SLC34A2 EXON Silent,Silent,Silent rs4697598 4 25679209 [A/C] NM_006424,NM_001177998,NM_001177999 SLC34A2,SLC34A2,SLC34A2 EXON Silent,Silent,Silent rs4600903 4 25680145 [A/G] NM_006424,NM_001177998,NM_001177999 SLC34A2,SLC34A2,SLC34A2 EXON Silent,Silent,Silent rs10005751 4 25681990 [A/C] rs6834960 4 25684294 [T/C] rs9654104 4 25702694 [T/C] rs868838 4 25705533 [T/G] rs7692656 4 25705912 [A/G] rs13152663 4 25707422 [A/G] rs6847649 4 25717754 [T/C] rs16877508 4 25721489 [A/G] rs4328901 4 25729059 [A/G] rs11721812 4 25730546 [T/C] rs11725059 4 25732848 [T/C] rs11935381 4 25734246 [A/G] rs4395489 4 25740206 [T/C] rs6823673 4 25744431 [T/C] rs7684489 4 25745088 [T/C] rs4697608 4 25745489 [A/G] rs7701 4 25749303 [A/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 EXON Silent,Silent,Silent rs4697610 4 25750849 [T/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs11736599 4 25755041 [T/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs4697613 4 25758940 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs4697614 4 25758995 [T/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs2286866 4 25759334 [G/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 EXON Missense_W901C,Missense_W1019C,Missense_W1054C rs2276953 4 25760828 [T/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs2276950 4 25760944 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs11731086 4 25761406 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs6810985 4 25765527 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs2290579 4 25769327 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs7686038 4 25769971 [T/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs4697617 4 25771115 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs6448402 4 25771973 [T/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs13128580 4 25772477 [T/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs6819016 4 25775034 [T/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs4697618 4 25775618 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs2309286 4 25779985 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs4697619 4 25780891 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs7667794 4 25784732 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs9997403 4 25784979 [A/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs3733543 4 25803830 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs16877576 4 25804108 [T/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs936232 4 25813070 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs6448405 4 25813119 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs10000609 4 25816048 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs1378952 4 25818473 [T/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs729317 4 25818674 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs6853283 4 25819194 [A/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs9991383 4 25820615 [T/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs10939083 4 25822281 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs7676030 4 25823624 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 EXON Synonymous_P275P,Synonymous_P393P,Synonymous_P428P rs9993404 4 25831039 [A/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs6847559 4 25837310 [T/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs17681098 4 25838526 [T/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs6448409 4 25846377 [A/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs6842695 4 25861359 [T/C] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs6831024 4 25863375 [T/G] NM_001297594,NM_001297592,NM_015187 SEL1L3,SEL1L3,SEL1L3 Silent,Silent,Silent rs13140429 4 25867118 [T/C] rs731284 4 25871101 [T/C] rs6820540 4 25874058 [A/G] rs1545606 4 25875261 [A/G] rs16877681 4 25876343 [A/C] rs13118224 4 25880334 [T/C] rs7681279 4 25881877 [T/C] rs12642988 4 25887058 [A/G] rs12512962 4 25895258 [T/C] rs12505367 4 25895433 [A/G] rs16877716 4 25905895 [A/G] rs6818008 4 25908919 [A/G] rs9647441 4 25911176 [T/C] rs878552 4 25913155 [T/C] rs2305670 4 25915858 [A/C] NM_001145432 SMIM20 EXON Silent rs936234 4 25919109 [A/G] NM_001145432 SMIM20 Silent rs6828696 4 25919478 [T/C] NM_001145432 SMIM20 Silent rs1123943 4 25924426 [T/C] NM_001145432 SMIM20 Silent rs2168523 4 25924857 [T/C] NM_001145432 SMIM20 Silent rs14553 4 25930928 [A/G] NM_001145432 SMIM20 EXON Silent rs554 4 25931325 [A/G] NM_001145432 SMIM20 EXON Silent rs16877751 4 25933737 [T/G] rs2309291 4 25940635 [A/C] rs6448417 4 25942460 [T/C] rs1456435 4 25942592 [T/C] rs7654585 4 25942751 [A/G] rs10939086 4 25950606 [A/G] rs10939087 4 25950625 [A/G] rs4692188 4 25951539 [A/G] rs4692198 4 25957151 [A/G] rs17627409 4 25958994 [T/C] rs6820447 4 25961788 [T/C] rs7440308 4 25967254 [T/C] rs2045329 4 25968931 [A/G] rs7676237 4 25969256 [A/G] rs2198844 4 25969618 [T/C] rs936235 4 25970163 [T/C] rs936236 4 25970325 [T/C] rs16877848 4 25975111 [T/C] rs10006741 4 25976544 [T/C] rs11728123 4 25983887 [A/G] rs11724348 4 25984065 [T/G] rs10939088 4 25987596 [A/G] rs6841503 4 25987977 [A/G] rs4234990 4 25988674 [T/C] rs4406006 4 25991628 [T/C] rs5029078 4 25992329 [T/C] rs6828206 4 25993237 [T/G] rs6828245 4 25993373 [A/C] rs6840416 4 26000595 [T/C] rs6837551 4 26005161 [T/C] rs12647908 4 26016156 [T/C] rs1027998 4 26017406 [A/G] rs6847589 4 26018690 [A/G] rs2063531 4 26019058 [A/G] rs17685537 4 26021208 [A/G] rs1512104 4 26021310 [A/G] rs4263391 4 26025073 [T/C] rs4287995 4 26025323 [A/G] rs12499714 4 26025487 [A/G] rs4269167 4 26025756 [T/C] rs1567648 4 26026106 [T/C] rs9884830 4 26027797 [T/C] rs9884387 4 26028187 [A/G] rs6846440 4 26028805 [T/C] rs12502605 4 26031528 [T/C] rs1033118 4 26032228 [A/C] rs9790578 4 26034030 [T/C] rs4692317 4 26037602 [T/C] rs6841440 4 26045697 [A/G] rs11736287 4 26047288 [A/G] rs2137231 4 26048141 [T/C] rs11731522 4 26050047 [A/G] rs17697268 4 26054418 [A/G] rs10155365 4 26056021 [A/G] rs13126784 4 26057402 [A/G] rs10032780 4 26060048 [T/C] rs1105912 4 26068018 [T/C] rs4692346 4 26072585 [A/G] rs16878074 4 26077520 [T/C] rs4558863 4 26079129 [T/C] rs2048507 4 26079164 [T/C] rs17697588 4 26079216 [T/C] rs907496 4 26081846 [A/G] rs6818978 4 26083058 [T/C] rs10517086 4 26085511 [A/G] rs10517087 4 26085546 [A/G] rs4692369 4 26092005 [T/C] rs6827904 4 26094755 [T/G] rs4692073 4 26100786 [T/C] rs10026498 4 26117952 [A/G] rs9991113 4 26121018 [A/G] rs4692386 4 26132361 [T/C] rs10939096 4 26133708 [T/C] rs7682322 4 26136773 [T/C] rs907498 4 26139677 [A/G] rs10033468 4 26142837 [A/G] rs11938515 4 26143620 [T/C] rs13140653 4 26147138 [T/C] rs4692399 4 26151057 [A/G] rs1581089 4 26155360 [T/C] rs12650853 4 26160310 [A/C] rs13115567 4 26163108 [T/C] rs7697053 4 26163751 [T/C] rs13150492 4 26166250 [A/G] rs9291482 4 26167227 [A/G] rs16878154 4 26172899 [A/G] rs1512105 4 26175955 [T/C] rs6824647 4 26177372 [T/C] rs4692424 4 26190536 [A/G] rs10017756 4 26197873 [A/G] rs10005500 4 26201527 [T/C] rs6838818 4 26203715 [T/C] rs4552442 4 26205938 [T/C] rs17823089 4 26208843 [T/G] rs11735620 4 26213763 [T/C] rs10939100 4 26218025 [A/G] rs7692708 4 26219793 [A/G] rs16878186 4 26220299 [A/G] rs7685350 4 26229299 [T/C] rs6850487 4 26230407 [A/G] rs1006802 4 26237157 [A/G] rs3857127 4 26237234 [A/G] rs10028140 4 26259369 [A/G] rs7655052 4 26273910 [T/C] rs11933748 4 26275139 [A/G] rs6831303 4 26275336 [A/G] rs13109468 4 26280575 [T/C] rs7671350 4 26286920 [A/G] rs2871198 4 26292555 [T/C] rs1877209 4 26299125 [T/C] rs2271384 4 26300494 [A/G] rs17644283 4 26308792 [A/G] rs11946144 4 26320071 [T/G] rs3822223 4 26321906 [A/C] NM_005349,NM_203283 RBPJ,RBPJ Silent,Silent rs6821126 4 26342538 [T/G] NM_005349,NM_203283,NM_015874,NM_203284,NM_001363577 RBPJ,RBPJ,RBPJ,RBPJ,RBPJ Silent,Silent,Silent,Silent,Silent rs12651502 4 26344169 [A/G] NM_005349,NM_203283,NM_015874,NM_203284,NM_001363577 RBPJ,RBPJ,RBPJ,RBPJ,RBPJ Silent,Silent,Silent,Silent,Silent rs7695991 4 26348730 [A/G] NM_005349,NM_203283,NM_015874,NM_203284,NM_001363577 RBPJ,RBPJ,RBPJ,RBPJ,RBPJ Silent,Silent,Silent,Silent,Silent rs10939109 4 26370183 [A/G] NM_005349,NM_203283,NM_015874,NM_203284,NM_001363577 RBPJ,RBPJ,RBPJ,RBPJ,RBPJ Silent,Silent,Silent,Silent,Silent rs2725326 4 26389462 [A/C] NM_005349,NM_203283,NM_015874,NM_203284,NM_001363577 RBPJ,RBPJ,RBPJ,RBPJ,RBPJ Silent,Silent,Silent,Silent,Silent rs3113014 4 26407878 [T/C] NM_005349,NM_203283,NM_015874,NM_203284,NM_001363577 RBPJ,RBPJ,RBPJ,RBPJ,RBPJ EXON Synonymous_Y60Y,Synonymous_Y45Y,Synonymous_Y47Y,Synonymous_Y46Y,Synonymous_Y25Y rs3109836 4 26408827 [A/C] NM_005349,NM_203283,NM_015874,NM_203284,NM_001363577 RBPJ,RBPJ,RBPJ,RBPJ,RBPJ Silent,Silent,Silent,Silent,Silent rs2788864 4 26416113 [A/G] NM_005349,NM_203283,NM_015874,NM_203284,NM_001363577 RBPJ,RBPJ,RBPJ,RBPJ,RBPJ Silent,Silent,Silent,Silent,Silent rs946346 4 26431386 [A/G] NM_005349,NM_203283,NM_015874,NM_203284,NM_001363577 RBPJ,RBPJ,RBPJ,RBPJ,RBPJ Silent,Silent,Silent,Silent,Silent rs6816542 4 26433551 [T/C] NM_005349,NM_203283,NM_015874,NM_203284,NM_001363577 RBPJ,RBPJ,RBPJ,RBPJ,RBPJ EXON Silent,Silent,Silent,Silent,Silent rs10805262 4 26439223 [T/C] rs10517099 4 26439486 [A/C] rs6833606 4 26440988 [A/G] rs6818128 4 26451326 [A/G] rs13116206 4 26451697 [A/G] rs3109848 4 26457168 [T/C] rs7691160 4 26457487 [T/G] rs16878356 4 26460048 [T/C] rs6826952 4 26460991 [T/C] rs13144195 4 26461373 [T/C] rs16878361 4 26461885 [A/G] rs2788853 4 26464646 [A/G] rs6854815 4 26466861 [A/G] rs716075 4 26468733 [T/C] rs716073 4 26468820 [A/C] rs716074 4 26468947 [T/C] rs3113032 4 26473220 [A/G] rs967413 4 26480145 [T/G] rs2854030 4 26482021 [T/C] rs1805037 4 26483659 [A/G] NM_000730 CCKAR EXON Synonymous_I296I rs7665027 4 26486909 [A/G] NM_000730 CCKAR Silent rs2725307 4 26489057 [A/C] NM_000730 CCKAR Silent rs1800856 4 26491768 [T/C] NM_000730 CCKAR Silent rs2854038 4 26493209 [A/G] rs869902 4 26498513 [A/C] rs10031898 4 26499696 [T/C] rs11733591 4 26501114 [T/C] rs11725410 4 26501372 [A/G] rs2130250 4 26504157 [T/G] rs7667060 4 26504723 [T/C] rs2130248 4 26504936 [A/C] rs13115937 4 26512016 [A/C] rs902095 4 26522349 [T/G] rs902096 4 26522786 [T/C] rs16878448 4 26527154 [T/C] rs13135516 4 26530421 [T/G] rs4692540 4 26530798 [T/G] rs1387542 4 26533333 [T/C] rs6838762 4 26534959 [A/G] rs6845307 4 26535661 [T/C] rs9992993 4 26551172 [T/C] rs3899075 4 26570153 [T/C] rs6838102 4 26572009 [A/G] rs2014308 4 26573764 [T/C] rs10805265 4 26585311 [T/C] rs4692549 4 26585881 [T/C] NM_001292054,NM_018317 TBC1D19,TBC1D19 EXON Synonymous_S22S,Synonymous_S22S rs12650361 4 26591253 [A/G] NM_001292054,NM_018317 TBC1D19,TBC1D19 Silent,Silent rs166353 4 26613455 [T/C] NM_001292054,NM_018317 TBC1D19,TBC1D19 Silent,Silent rs260955 4 26617438 [T/C] NM_001292054,NM_018317 TBC1D19,TBC1D19 Silent,Silent rs1362505 4 26619425 [A/G] NM_001292054,NM_018317 TBC1D19,TBC1D19 Silent,Silent rs11944695 4 26620600 [A/G] NM_001292054,NM_018317 TBC1D19,TBC1D19 Silent,Silent rs260958 4 26625185 [A/G] NM_001292054,NM_018317 TBC1D19,TBC1D19 Silent,Silent rs1558722 4 26672973 [A/C] NM_001292054,NM_018317 TBC1D19,TBC1D19 Silent,Silent rs7691219 4 26673787 [A/G] NM_001292054,NM_018317 TBC1D19,TBC1D19 EXON Synonymous_E162E,Synonymous_E227E rs4583745 4 26690284 [A/G] NM_001292054,NM_018317 TBC1D19,TBC1D19 Silent,Silent rs7674362 4 26746830 [A/G] NM_001292054,NM_018317 TBC1D19,TBC1D19 Silent,Silent rs1129230 4 26756855 [A/C] NM_001292054,NM_018317 TBC1D19,TBC1D19 EXON Silent,Silent rs5024581 4 26780582 [A/G] rs7441238 4 26792218 [A/G] rs4428270 4 26793681 [A/C] rs4261979 4 26809177 [A/G] rs4299571 4 26817610 [A/G] rs7692829 4 26822377 [A/G] rs6856464 4 26822998 [A/G] rs7676115 4 26826309 [T/C] rs6821586 4 26828438 [T/C] rs6448475 4 26831827 [T/C] rs6839242 4 26835952 [T/C] rs7688120 4 26836909 [T/C] rs4407490 4 26839460 [T/C] rs3924178 4 26843494 [A/G] rs7688662 4 26844469 [A/G] rs7660174 4 26852438 [T/G] rs6848664 4 26853149 [T/C] rs4133239 4 26853232 [T/C] rs4449404 4 26860909 [T/C] rs9790789 4 26861656 [A/C] NR_134675,NR_134673,NR_134674 LOC105374546,LOC105374546,LOC105374546 Silent,Silent,Silent rs10029816 4 26861674 [A/G] NR_134675,NR_134673,NR_134674 LOC105374546,LOC105374546,LOC105374546 Silent,Silent,Silent rs6833053 4 26872460 [A/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs10006403 4 26873700 [A/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs13150500 4 26880755 [A/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs6815719 4 26881854 [A/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs10022599 4 26894656 [A/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs10023256 4 26902361 [T/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs12642608 4 26911000 [T/C] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs7692953 4 26938136 [T/C] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs7658174 4 26945149 [A/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs10030655 4 26950265 [T/C] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs10032186 4 26962873 [A/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs16878655 4 26966277 [A/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs10433805 4 26970376 [T/C] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs2192241 4 26986737 [A/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs11940153 4 26987761 [A/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs6822297 4 27000995 [A/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs10028164 4 27004011 [A/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 EXON Synonymous_Q266Q,Synonymous_Q266Q,Synonymous_Q266Q rs4692137 4 27005235 [A/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs6855865 4 27011357 [A/G] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs6830950 4 27016468 [T/C] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs6853163 4 27023347 [T/C] NM_001169118,NM_001169117,NM_020860 STIM2,STIM2,STIM2 Silent,Silent,Silent rs9998590 4 27034672 [A/G] rs16878720 4 27045049 [T/C] rs16878739 4 27056744 [A/G] rs10002029 4 27057188 [T/C] rs7678869 4 27060775 [T/C] rs4692020 4 27067027 [T/C] rs16878757 4 27068060 [A/G] rs17570945 4 27070339 [A/G] rs6448497 4 27078376 [A/G] rs7682298 4 27079446 [A/G] rs7653933 4 27081704 [A/G] rs741135 4 27083248 [A/G] rs13144846 4 27086066 [A/G] rs16878829 4 27087177 [A/G] rs4692163 4 27087570 [T/C] rs4692164 4 27087761 [A/G] rs7677573 4 27096261 [A/G] rs12503097 4 27097098 [A/G] rs2075093 4 27097696 [T/G] rs2041627 4 27102429 [A/C] rs6835095 4 27103530 [T/C] rs13113425 4 27115301 [T/G] rs16878852 4 27115685 [T/C] rs969949 4 27122947 [T/C] rs4692169 4 27124674 [A/G] rs7685249 4 27125382 [T/C] rs6813524 4 27127678 [A/G] rs13148066 4 27130269 [T/G] rs17589537 4 27132182 [A/G] rs10939150 4 27134618 [A/G] rs6853864 4 27139247 [A/G] rs16878895 4 27148758 [A/G] rs13105110 4 27148768 [T/C] rs16878908 4 27152560 [A/C] rs1013532 4 27157313 [A/G] rs1352374 4 27157547 [T/C] rs6448500 4 27166535 [A/G] rs7668273 4 27172128 [A/G] rs13101823 4 27175502 [A/G] rs1488274 4 27180604 [A/G] rs993967 4 27180841 [A/G] rs4692174 4 27186432 [T/C] rs1982810 4 27186835 [A/G] rs1488290 4 27197786 [T/C] rs16878986 4 27199971 [A/G] rs6826441 4 27202594 [A/G] rs1488268 4 27209559 [T/G] rs13130950 4 27209596 [T/C] rs2046701 4 27211040 [A/C] rs13127219 4 27211999 [T/C] rs4639059 4 27216501 [T/C] rs901832 4 27216662 [T/C] rs901833 4 27216751 [A/G] rs17591786 4 27218939 [A/G] rs13118735 4 27219736 [A/G] NR_125921 LINC02261 Silent rs11724172 4 27219806 [T/C] NR_125921 LINC02261 Silent rs13142026 4 27223375 [A/G] NR_125921 LINC02261 Silent rs12511504 4 27225759 [T/C] NR_125921 LINC02261 Silent rs2029319 4 27229288 [A/C] NR_125921 LINC02261 Silent rs13118370 4 27230197 [T/C] NR_125921 LINC02261 Silent rs7673254 4 27235976 [A/G] NR_125921 LINC02261 Silent rs13121254 4 27239274 [T/C] NR_125921 LINC02261 Silent rs10015926 4 27241002 [A/G] NR_125921 LINC02261 Silent rs4466027 4 27248702 [A/G] NR_125921 LINC02261 Silent rs9291493 4 27252907 [T/C] NR_125921 LINC02261 Silent rs7356206 4 27254091 [A/C] NR_125921 LINC02261 Silent rs6448506 4 27256570 [T/C] NR_125921 LINC02261 Silent rs1488298 4 27261129 [A/G] NR_125921 LINC02261 Silent rs1488299 4 27261443 [T/C] NR_125921 LINC02261 Silent rs1386901 4 27261688 [A/C] NR_125921 LINC02261 Silent rs16879070 4 27262518 [A/G] NR_125921 LINC02261 Silent rs5002502 4 27263045 [T/C] NR_125921 LINC02261 Silent rs6854240 4 27264542 [T/C] NR_125921 LINC02261 Silent rs748057 4 27268342 [T/C] NR_125921 LINC02261 Silent rs1488281 4 27269408 [A/G] NR_125921 LINC02261 Silent rs4550907 4 27272143 [T/C] NR_125921 LINC02261 Silent rs10939154 4 27276248 [A/G] NR_125921 LINC02261 Silent rs6848074 4 27280902 [A/G] NR_125921 LINC02261 Silent rs2029321 4 27287137 [T/C] rs6812821 4 27288616 [A/G] rs1488275 4 27292819 [A/G] rs6854189 4 27294467 [A/G] rs16879148 4 27296405 [T/C] rs10489014 4 27298022 [T/C] rs6821695 4 27298305 [T/C] rs2309558 4 27310241 [T/G] rs6849084 4 27311479 [A/G] rs2192195 4 27314726 [A/G] rs13115333 4 27323221 [T/G] rs12644961 4 27324215 [A/G] rs11727052 4 27326253 [A/G] rs10021654 4 27331116 [A/G] rs7662818 4 27335003 [A/C] rs759097 4 27337756 [T/C] rs4692196 4 27339904 [T/C] rs6819555 4 27342170 [A/G] rs1000516 4 27352006 [A/G] rs9291495 4 27355782 [T/G] rs2215745 4 27358898 [A/G] rs7690010 4 27360257 [T/C] rs13147990 4 27360968 [T/C] rs16879192 4 27362571 [T/C] rs13134892 4 27362740 [T/C] rs2871278 4 27367496 [A/G] rs10489015 4 27373502 [T/C] rs10012661 4 27373821 [T/C] rs6448515 4 27374368 [T/G] rs13107491 4 27383785 [A/G] rs4355380 4 27388554 [A/G] rs6448518 4 27390449 [A/G] rs7672972 4 27405561 [T/C] rs11934618 4 27406076 [T/G] rs210755 4 27406431 [T/C] rs210760 4 27412242 [A/G] rs210761 4 27412694 [T/C] rs10014971 4 27419092 [T/C] rs210777 4 27432523 [A/G] rs210749 4 27438947 [T/C] rs16879368 4 27440377 [T/G] rs2110177 4 27442060 [T/C] rs10489017 4 27448881 [A/G] rs210782 4 27450750 [A/C] rs10025989 4 27459128 [T/C] rs11935805 4 27471892 [T/C] rs6849304 4 27474865 [A/G] rs6856266 4 27483170 [A/G] rs10461103 4 27490495 [A/G] rs1378788 4 27496294 [A/G] rs1993400 4 27496410 [T/C] rs9999163 4 27509127 [A/G] rs12505179 4 27509411 [T/C] rs12505247 4 27509621 [T/C] rs12108234 4 27520046 [A/G] rs12506982 4 27530174 [T/C] rs1375757 4 27534772 [T/C] rs9992655 4 27534917 [A/G] rs12504241 4 27539764 [A/G] rs16879469 4 27542201 [A/C] rs1449756 4 27542684 [T/C] rs10009898 4 27548905 [T/C] rs13124025 4 27553045 [T/C] rs10506518 4 27560693 [A/G] rs16879491 4 27570669 [T/C] rs6856564 4 27584802 [T/G] rs10049673 4 27584821 [T/C] rs16879540 4 27591317 [A/G] rs16879550 4 27592104 [T/C] rs16879558 4 27595859 [A/G] rs4599400 4 27600788 [T/C] rs1375761 4 27601868 [A/G] rs16879587 4 27602132 [A/C] rs7658517 4 27602249 [T/C] rs6847492 4 27603144 [T/C] rs10212920 4 27606650 [T/C] rs7697958 4 27614790 [T/C] rs6448527 4 27624165 [T/C] rs6448528 4 27624182 [T/G] rs6448529 4 27624322 [T/G] rs12499725 4 27634211 [T/C] rs6838915 4 27634979 [T/G] rs7671071 4 27637428 [A/G] rs297282 4 27642019 [A/C] rs454414 4 27655235 [T/C] rs9291503 4 27658052 [T/C] rs2034472 4 27661645 [T/G] rs7671299 4 27661893 [A/G] rs297291 4 27671803 [T/C] rs6846226 4 27675410 [T/C] rs297279 4 27680483 [T/C] rs1449766 4 27687397 [A/G] rs1031311 4 27694893 [T/G] rs297316 4 27702295 [A/G] rs6448532 4 27704222 [T/G] rs297308 4 27714566 [A/G] rs297306 4 27715503 [A/G] rs16879698 4 27718287 [A/G] rs1992981 4 27719790 [A/G] rs13126571 4 27725689 [A/G] rs1472691 4 27726979 [A/G] rs6841905 4 27727259 [A/G] rs10028171 4 27735936 [T/C] rs4450914 4 27739598 [A/G] rs13108163 4 27742689 [A/G] rs1503465 4 27744290 [T/C] rs10517129 4 27753361 [T/C] rs13110484 4 27757391 [T/C] rs17669368 4 27757473 [T/C] rs10014448 4 27760141 [A/G] rs7677623 4 27763567 [A/G] rs2202258 4 27779332 [A/G] rs7685758 4 27782417 [T/C] rs16879755 4 27782716 [A/G] rs1503454 4 27783448 [T/C] rs2309628 4 27790945 [T/C] rs13119429 4 27792360 [T/C] rs12640417 4 27793744 [T/G] rs16879791 4 27795958 [T/C] rs13144861 4 27797571 [T/C] rs16879804 4 27803032 [T/C] rs7686302 4 27805588 [A/C] rs12643611 4 27811805 [T/C] rs13112218 4 27812345 [T/C] rs17671452 4 27813390 [A/G] rs16879832 4 27821792 [A/G] rs7660570 4 27824071 [T/C] rs16879845 4 27826209 [A/G] rs11728477 4 27828760 [A/G] rs1905564 4 27828999 [A/C] rs7686975 4 27831637 [T/G] rs6832303 4 27833499 [A/G] rs6829231 4 27837969 [A/C] rs12640014 4 27848155 [A/C] rs12648098 4 27867951 [A/G] rs6856472 4 27871868 [T/C] rs7656782 4 27878240 [A/C] rs10939176 4 27882142 [T/C] rs6842063 4 27896510 [T/C] rs11736171 4 27897437 [T/C] rs6857890 4 27902479 [A/G] rs6857913 4 27902507 [A/G] rs16879958 4 27902560 [T/C] rs16879960 4 27905331 [T/C] rs6841769 4 27905536 [A/C] rs17616472 4 27906829 [T/C] rs1038441 4 27907123 [A/C] rs17616508 4 27907530 [T/C] rs1026947 4 27912160 [A/G] rs1292621 4 27914446 [T/C] rs2110510 4 27918627 [A/G] rs4692262 4 27924831 [A/C] rs4692044 4 27925154 [A/G] rs6844406 4 27928459 [A/G] rs10016121 4 27931573 [A/G] rs7684360 4 27940513 [T/C] rs6813435 4 27943218 [A/G] rs756526 4 27943852 [T/C] rs16880018 4 27946125 [A/G] rs9990661 4 27947900 [T/C] rs2067760 4 27955784 [A/G] rs7659592 4 27961533 [A/G] rs7665009 4 27961828 [T/C] rs9884587 4 27966505 [T/C] rs2058574 4 27971596 [T/G] rs16880029 4 27971792 [T/C] rs10029165 4 27975847 [A/G] rs929620 4 27983025 [T/C] rs12511506 4 27997335 [T/C] rs11932274 4 28000670 [T/G] rs4692270 4 28003277 [T/C] rs16880055 4 28005075 [T/C] rs1125825 4 28016367 [T/G] rs16880102 4 28017161 [T/C] rs1405674 4 28017651 [A/C] rs1527339 4 28024351 [A/G] rs1358311 4 28032948 [A/C] rs4692272 4 28036809 [T/C] rs2110506 4 28046364 [T/C] rs725070 4 28052469 [A/G] rs16880200 4 28055549 [A/G] rs11726566 4 28057728 [A/G] rs13116924 4 28067758 [A/G] rs1918326 4 28071228 [T/C] rs6850690 4 28077002 [A/G] rs13109572 4 28087933 [T/C] rs10033212 4 28090064 [A/G] rs6824779 4 28098085 [T/C] rs6858327 4 28099442 [T/C] rs10031833 4 28101706 [T/C] rs11930990 4 28103790 [A/G] rs2037766 4 28104319 [T/C] rs16880241 4 28109929 [A/G] rs1609116 4 28122494 [T/G] rs9291509 4 28145416 [A/G] rs10030204 4 28146839 [A/C] rs13135412 4 28153349 [T/G] rs13110407 4 28155171 [T/C] rs1527328 4 28157447 [A/C] rs1918317 4 28158128 [T/C] rs1918316 4 28158977 [A/G] rs16880315 4 28160456 [A/G] rs1534293 4 28161145 [A/G] rs16880317 4 28162665 [T/G] rs13130395 4 28170335 [A/G] rs6835345 4 28175258 [A/G] rs4692290 4 28182874 [A/G] rs12642383 4 28194516 [A/G] rs10009033 4 28194748 [A/G] rs4318636 4 28204105 [A/G] rs16880367 4 28216699 [A/G] rs4692293 4 28224533 [T/G] rs10517137 4 28226334 [A/C] rs7660232 4 28232617 [A/G] rs1497691 4 28233327 [T/C] rs4452420 4 28233491 [T/C] rs12648254 4 28234453 [T/C] rs973586 4 28234938 [T/C] rs2173279 4 28237783 [A/C] rs2309717 4 28250238 [A/C] rs11729367 4 28251958 [T/C] rs1497716 4 28270157 [A/C] rs7435189 4 28292048 [A/G] rs4423858 4 28300470 [A/G] rs7654040 4 28305543 [T/C] rs4267724 4 28315343 [T/G] rs13137916 4 28319636 [T/C] rs10025742 4 28324928 [T/C] rs985959 4 28338121 [A/C] rs2036184 4 28345775 [T/C] rs10517141 4 28352417 [T/C] rs7655306 4 28352861 [T/C] rs7678990 4 28353593 [A/G] rs12649612 4 28353949 [A/G] rs10939207 4 28360614 [A/G] rs12645676 4 28374425 [A/G] rs16880558 4 28378505 [T/C] rs664330 4 28378795 [A/C] rs16880561 4 28378913 [A/G] rs7697734 4 28379146 [T/C] rs1282883 4 28379401 [A/G] rs7674497 4 28391626 [T/C] rs1510705 4 28405478 [A/G] rs12502704 4 28419100 [A/G] rs16880624 4 28419921 [A/G] rs2250259 4 28433243 [A/G] rs3907987 4 28440972 [T/C] rs10028579 4 28450862 [T/C] rs17685351 4 28454474 [T/G] rs10939214 4 28460198 [A/G] rs7687734 4 28460356 [A/G] rs292036 4 28466473 [A/G] rs12642662 4 28470784 [T/C] rs16880691 4 28473048 [A/C] rs675680 4 28473086 [A/G] rs962625 4 28473524 [A/G] rs292034 4 28478119 [T/G] rs7656054 4 28480415 [A/G] rs7662460 4 28481058 [A/G] rs7653895 4 28485201 [T/C] rs10049513 4 28497681 [T/C] rs11937136 4 28503413 [T/G] rs1514120 4 28506594 [T/C] rs11934051 4 28513407 [A/G] rs292050 4 28523533 [T/G] rs292049 4 28525051 [T/C] rs16880729 4 28525185 [A/G] rs292044 4 28534342 [T/G] rs2136818 4 28539800 [T/C] rs292016 4 28544298 [T/G] rs557255 4 28547108 [T/C] rs17698720 4 28549589 [A/G] rs12645493 4 28555328 [A/G] rs6448587 4 28561990 [A/C] rs2458614 4 28563455 [A/G] rs16880793 4 28585618 [A/G] rs2943159 4 28587729 [T/G] rs7655801 4 28588964 [T/C] rs2471712 4 28589663 [T/C] rs3114003 4 28590366 [T/G] rs11946058 4 28590750 [A/G] rs1514125 4 28592154 [A/G] rs16880825 4 28602089 [A/G] rs11945665 4 28603169 [A/C] rs10939219 4 28603878 [T/G] rs17644064 4 28608116 [A/G] rs12509357 4 28614705 [T/C] rs11943453 4 28618870 [A/G] rs10005058 4 28620097 [A/C] rs16880861 4 28622364 [A/C] rs16880871 4 28634864 [T/C] rs7672198 4 28637078 [T/G] rs6831370 4 28641062 [A/G] rs6844353 4 28642726 [A/G] rs4334744 4 28648262 [T/C] rs16880878 4 28654502 [A/G] rs2172455 4 28658506 [A/G] rs6839719 4 28659854 [T/C] rs9996729 4 28660856 [T/C] rs1493137 4 28661714 [A/G] rs953276 4 28664019 [T/C] rs16880901 4 28665838 [A/G] rs1493133 4 28669055 [T/G] rs1389169 4 28669712 [A/G] rs7663065 4 28687406 [A/G] rs4692338 4 28691851 [A/G] rs11937968 4 28692384 [A/G] rs16880969 4 28702554 [T/G] rs11945047 4 28702690 [A/G] rs13114499 4 28703576 [T/C] rs7693029 4 28703891 [A/G] rs7698388 4 28710321 [A/G] rs10939225 4 28712968 [A/G] rs6811481 4 28713717 [T/C] rs12648749 4 28713799 [A/G] rs9685881 4 28718528 [T/C] rs1389182 4 28718982 [T/G] rs4692342 4 28723573 [T/C] rs11722802 4 28723854 [A/G] rs2309883 4 28732481 [T/C] rs13143929 4 28737332 [T/C] rs2047033 4 28737881 [A/G] rs10001415 4 28738088 [T/C] rs2047032 4 28738315 [A/C] rs12508326 4 28745882 [A/G] rs16881041 4 28750923 [T/C] rs9997504 4 28752825 [A/G] rs9997604 4 28752932 [A/C] rs11946866 4 28753519 [T/G] rs12508012 4 28758097 [T/C] rs11945416 4 28761153 [T/C] rs1353053 4 28764584 [T/G] rs7664880 4 28769842 [T/G] rs1493139 4 28776140 [T/C] rs12512663 4 28780231 [A/G] rs7686662 4 28790775 [T/G] rs9991797 4 28795213 [T/G] rs6813605 4 28795323 [T/C] rs2131464 4 28795758 [T/C] rs12499758 4 28796401 [T/C] rs4234998 4 28797388 [A/G] rs13106844 4 28799523 [A/C] rs1602798 4 28815914 [A/G] rs7349599 4 28816220 [A/G] rs6844183 4 28821006 [A/G] rs1873861 4 28826217 [A/G] rs11942403 4 28829163 [A/G] rs6843375 4 28831319 [T/C] rs16881070 4 28831639 [T/G] rs6850240 4 28832388 [A/G] rs6850637 4 28832545 [A/G] rs17653404 4 28832740 [A/G] rs6833159 4 28832788 [T/C] rs2029669 4 28833274 [T/C] rs1493164 4 28834160 [A/G] rs2047028 4 28838826 [A/G] rs11937670 4 28841188 [T/C] rs4441746 4 28843468 [T/G] rs7661449 4 28845331 [T/C] rs7695045 4 28850524 [A/G] rs12645808 4 28851586 [T/C] rs7698028 4 28863159 [A/G] rs7438460 4 28865191 [A/G] rs7661966 4 28866526 [T/C] rs11930458 4 28869604 [T/G] rs10049756 4 28872833 [A/G] rs7658708 4 28887284 [A/G] rs10805281 4 28895078 [A/G] rs12647787 4 28901589 [A/G] rs13109384 4 28912626 [A/G] rs13112132 4 28921523 [T/G] rs4692065 4 28922949 [T/C] rs1402492 4 28923633 [T/G] rs1402499 4 28928041 [T/C] rs2222357 4 28932131 [A/C] rs12642441 4 28933593 [T/G] rs4326073 4 28935317 [A/G] rs1402504 4 28936849 [A/G] rs1521131 4 28940143 [T/C] rs4639141 4 28945208 [A/G] rs6448614 4 28947647 [A/G] rs1521123 4 28948730 [A/G] rs12649705 4 28949043 [A/C] rs16881220 4 28954136 [T/C] rs17705257 4 28955155 [T/C] rs16881228 4 28955778 [A/G] rs7674882 4 28956150 [T/C] rs13148843 4 28956166 [T/C] rs7696952 4 28956361 [T/C] rs16881249 4 28957536 [T/C] rs1357033 4 28958205 [A/G] rs7670784 4 28959562 [T/C] rs7688399 4 28967598 [A/G] rs6448619 4 28972033 [T/C] rs6815902 4 28975242 [T/C] rs6843077 4 28979210 [T/C] rs7664803 4 28983128 [A/G] rs11944473 4 28990864 [T/G] rs4285150 4 28995299 [A/G] rs13108377 4 28999923 [A/C] NR_146499 LINC02364 Silent rs11936386 4 29004411 [A/G] NR_146499 LINC02364 Silent rs1402487 4 29016593 [A/G] rs2049156 4 29018173 [A/G] rs17655022 4 29030161 [T/G] rs3924180 4 29046559 [T/C] rs7677192 4 29048204 [A/G] rs4128512 4 29060867 [T/C] rs7684905 4 29066896 [A/G] rs1402481 4 29069894 [A/G] rs4571399 4 29081102 [A/G] rs13103421 4 29081919 [T/C] rs11934543 4 29095909 [A/G] rs12644773 4 29106713 [T/C] rs10009272 4 29126230 [T/C] rs4401510 4 29129308 [T/G] rs10939244 4 29129922 [A/G] rs7694767 4 29135014 [T/G] rs7671430 4 29135608 [T/C] rs6820781 4 29141525 [A/G] rs6448630 4 29153921 [T/C] rs10939245 4 29154922 [T/G] rs4285149 4 29164477 [A/C] rs1507439 4 29195105 [T/G] rs10517155 4 29203553 [T/C] rs16881492 4 29203881 [A/G] rs11929806 4 29204907 [A/G] rs7696414 4 29220153 [T/G] NR_146996 LINC02472 Silent rs2019100 4 29224491 [T/C] rs2117896 4 29229619 [A/G] rs6824303 4 29241920 [T/C] rs7665501 4 29246863 [T/C] rs13121140 4 29247786 [A/G] rs6837434 4 29249394 [A/G] rs12651167 4 29263872 [A/G] rs11947802 4 29275203 [A/G] rs10033492 4 29287401 [A/C] rs12331067 4 29289447 [A/G] rs10007790 4 29293274 [A/G] rs13148111 4 29293875 [A/G] rs7696776 4 29294481 [A/C] rs1369801 4 29296845 [T/C] rs17714421 4 29299647 [A/G] rs4264889 4 29302397 [A/C] rs4588519 4 29303608 [T/C] rs4521412 4 29306747 [A/G] rs1821687 4 29309079 [T/C] rs2310011 4 29309684 [T/C] rs1436063 4 29310397 [A/G] rs1821685 4 29311144 [T/C] rs10517158 4 29314359 [A/G] rs13114893 4 29314598 [T/C] rs4604115 4 29317918 [A/C] rs11939462 4 29318283 [A/G] rs34359528 4 29318326 [A/G] rs16867887 4 29324896 [T/C] rs1836779 4 29330467 [T/C] rs1025605 4 29331117 [A/G] rs4611992 4 29334731 [A/G] rs13103862 4 29335025 [A/G] rs6448638 4 29335563 [T/C] rs4434324 4 29338216 [A/C] rs6817648 4 29339030 [T/C] rs1436058 4 29339512 [T/C] rs2310014 4 29342591 [T/C] rs6817219 4 29347765 [A/G] rs195444 4 29364680 [A/G] rs181999 4 29365966 [A/G] rs479245 4 29368526 [A/G] rs16881704 4 29369219 [A/G] rs260930 4 29376155 [A/G] rs997412 4 29379799 [T/G] rs988366 4 29382730 [A/G] rs16881736 4 29395383 [T/C] rs11936766 4 29400203 [A/G] rs166333 4 29404976 [T/C] rs260122 4 29407530 [A/G] rs1155595 4 29419157 [A/C] rs16881791 4 29420040 [T/C] rs16881804 4 29423741 [A/G] rs16881815 4 29425637 [A/G] rs11737315 4 29429417 [T/G] rs16881823 4 29430546 [A/C] rs2310033 4 29441731 [T/C] rs6811398 4 29442576 [A/G] rs10011903 4 29446907 [T/C] rs6843590 4 29452617 [A/C] rs13142018 4 29458432 [T/G] rs10016065 4 29465881 [A/G] rs10517163 4 29472050 [T/C] rs1980023 4 29478879 [T/C] rs4692392 4 29489354 [T/C] rs7666825 4 29496936 [A/C] rs6851037 4 29497594 [T/C] rs7654387 4 29502336 [A/G] rs13106649 4 29508260 [T/C] rs10517167 4 29508413 [T/G] rs10517168 4 29508477 [A/C] rs9991320 4 29510895 [T/G] rs6818222 4 29520647 [A/G] rs355458 4 29522117 [A/G] rs10019636 4 29524988 [T/C] rs1837811 4 29531282 [A/G] rs11723936 4 29532602 [T/C] rs13122823 4 29538611 [T/C] rs7666106 4 29544573 [T/C] rs10019440 4 29554873 [T/C] rs1372309 4 29555818 [A/G] rs1441671 4 29574009 [A/G] rs1441670 4 29590146 [A/G] rs4407458 4 29608313 [T/C] rs11722750 4 29612612 [T/G] rs10029448 4 29612773 [A/C] rs6823799 4 29614694 [A/G] rs7688471 4 29618562 [A/G] rs11726757 4 29620820 [T/C] rs10002254 4 29626865 [A/G] rs10805294 4 29636690 [A/G] rs10939268 4 29638883 [A/G] rs16882044 4 29649572 [T/C] rs16882050 4 29652282 [T/C] rs7671757 4 29655893 [A/G] rs10024677 4 29656702 [A/G] rs4692409 4 29660543 [A/C] rs4692410 4 29663459 [T/G] rs4624623 4 29666276 [T/C] rs13103435 4 29673009 [A/G] rs13103446 4 29673019 [A/G] rs9291530 4 29673981 [T/C] rs7673510 4 29680847 [A/G] rs13138115 4 29682788 [T/G] rs6846124 4 29683641 [T/C] rs10018139 4 29684653 [T/C] rs10018343 4 29684913 [T/C] rs16882126 4 29685111 [T/G] rs16882129 4 29688391 [T/C] rs10033986 4 29689796 [A/G] rs10011902 4 29690077 [A/G] rs10939271 4 29690129 [A/C] rs7664033 4 29691666 [A/C] rs13128006 4 29693864 [T/C] rs13104601 4 29696261 [T/C] rs11943301 4 29699520 [A/G] rs13134458 4 29700316 [A/G] rs7692836 4 29710556 [T/C] rs16882167 4 29712547 [A/G] rs16882170 4 29713447 [T/C] rs12641649 4 29725653 [A/G] rs12641755 4 29726094 [A/G] rs2310077 4 29729748 [A/C] rs6853827 4 29735485 [T/C] rs2310084 4 29739635 [A/C] rs16882206 4 29740429 [T/C] rs16882209 4 29743040 [T/C] rs17735010 4 29743168 [A/G] rs7666527 4 29750408 [A/G] rs16882217 4 29752299 [T/C] rs7664238 4 29755511 [A/C] rs10020813 4 29756029 [A/G] rs16882230 4 29759983 [A/C] rs7670151 4 29763347 [A/C] rs10001236 4 29763937 [T/G] rs16882245 4 29770254 [A/G] rs2310091 4 29770652 [T/C] rs6811040 4 29773273 [T/C] rs16882258 4 29775082 [T/C] rs2047870 4 29777723 [T/C] rs2062844 4 29783037 [T/C] rs7664227 4 29785534 [A/C] rs7654268 4 29796112 [A/G] rs1995488 4 29801069 [T/C] rs16882322 4 29802111 [T/C] rs16882325 4 29802167 [T/C] rs4367136 4 29802767 [A/G] rs11722527 4 29804231 [A/G] rs1503971 4 29811570 [T/C] rs16882354 4 29817230 [T/C] rs11932609 4 29819581 [T/C] rs28655724 4 29825693 [T/C] rs2202308 4 29826189 [A/G] rs1472711 4 29837834 [T/C] rs11723563 4 29838345 [T/C] rs10939282 4 29857785 [T/C] rs1394130 4 29869342 [T/C] rs10002241 4 29869902 [T/C] rs10016642 4 29892538 [A/C] rs17737828 4 29897820 [T/C] rs7672855 4 29899300 [A/G] rs7442317 4 29903052 [A/G] rs16882465 4 29909867 [A/C] rs10001348 4 29912308 [A/G] rs10023178 4 29917438 [A/G] rs10049514 4 29927916 [T/C] rs1503966 4 29929502 [T/C] rs12506164 4 29943810 [T/G] rs10026184 4 29946101 [A/G] rs16882590 4 29946861 [T/C] rs6846051 4 29947072 [T/C] rs6837917 4 29949591 [T/C] rs10028915 4 29953808 [A/G] rs4692430 4 29962266 [T/C] rs6848673 4 29972531 [T/C] rs11943991 4 29982657 [A/G] rs4466010 4 29983877 [A/G] rs10939287 4 29985899 [A/G] rs12331629 4 29998225 [A/G] rs3884638 4 29998461 [A/C] rs11939224 4 30003939 [T/C] rs4593088 4 30004497 [T/C] rs10012732 4 30005434 [T/C] rs6840125 4 30025294 [T/C] rs4692435 4 30055645 [A/G] rs4377550 4 30059039 [T/C] rs12499826 4 30063389 [T/C] rs2310135 4 30086484 [A/G] rs6813280 4 30092152 [A/G] rs4594684 4 30095222 [T/C] rs2310129 4 30102488 [A/C] rs13120387 4 30108394 [T/C] rs2613180 4 30132119 [T/C] rs2571494 4 30134048 [A/G] rs17688808 4 30135529 [T/C] rs2571483 4 30144820 [T/C] rs7689614 4 30147719 [A/G] rs1469784 4 30156463 [T/G] rs6836424 4 30161847 [T/G] rs2613167 4 30162762 [T/G] rs6815106 4 30167692 [A/G] rs16882976 4 30168595 [A/G] rs7691359 4 30169493 [T/G] rs16882984 4 30170140 [T/C] rs7698204 4 30173651 [T/G] rs11732479 4 30174983 [A/G] rs1369184 4 30180666 [T/C] rs2256587 4 30184038 [A/G] rs976057 4 30193761 [T/C] rs2247063 4 30198753 [T/C] rs2613184 4 30203202 [T/C] rs1821544 4 30205924 [T/C] rs2053146 4 30210354 [A/G] rs2871431 4 30214893 [A/G] rs2571468 4 30215673 [A/G] rs7662079 4 30216257 [A/G] rs2571486 4 30218577 [T/G] rs16883111 4 30223294 [T/C] rs7667202 4 30224009 [A/G] rs3113774 4 30231510 [T/C] rs2571499 4 30235629 [T/C] rs16883126 4 30238980 [T/C] rs7668302 4 30242957 [T/C] rs4692446 4 30243958 [T/G] rs12512963 4 30267263 [T/G] rs1434827 4 30277791 [A/G] rs11943105 4 30283576 [A/G] rs3857027 4 30283750 [A/G] rs16883227 4 30286607 [T/C] rs1595049 4 30295729 [T/C] rs16883282 4 30312547 [A/G] rs1435779 4 30313458 [A/G] rs6858072 4 30315305 [A/C] rs12647147 4 30324241 [A/G] rs10049908 4 30328822 [T/G] rs7675877 4 30328911 [A/G] rs7661846 4 30334017 [A/G] rs16883353 4 30346867 [T/C] rs12510958 4 30348364 [T/C] rs9985782 4 30361791 [A/G] rs7655653 4 30363282 [A/G] rs7698788 4 30371605 [T/C] rs12509641 4 30384018 [A/G] rs7695486 4 30392084 [A/G] rs11931286 4 30394278 [A/G] rs7681280 4 30395518 [A/G] rs1435782 4 30397570 [A/G] rs4346608 4 30403040 [T/C] rs9998501 4 30403871 [T/C] rs1435787 4 30407029 [A/G] rs1369660 4 30409883 [T/C] rs3846269 4 30412195 [T/C] rs6847061 4 30412285 [T/C] rs3846270 4 30412796 [T/C] rs1836702 4 30413369 [A/C] rs12503525 4 30416966 [T/C] rs6818540 4 30427517 [A/G] rs1355580 4 30429557 [T/G] rs16883487 4 30431038 [T/C] rs2871445 4 30431211 [A/C] rs6448707 4 30431573 [T/C] rs16883507 4 30432141 [T/C] rs2203140 4 30436488 [A/G] rs9291540 4 30437096 [T/C] rs6841092 4 30439397 [T/C] rs4692457 4 30439878 [A/G] rs966770 4 30451158 [T/C] rs2164384 4 30452567 [T/C] rs9997877 4 30453124 [A/G] rs12641659 4 30453156 [A/G] rs7700123 4 30455876 [A/G] rs17763343 4 30459400 [T/C] rs16883593 4 30460011 [A/G] rs1512155 4 30461539 [A/C] rs10008525 4 30466859 [A/G] rs13143903 4 30467399 [A/G] rs1896180 4 30467623 [T/C] rs1955311 4 30471257 [T/C] rs1980054 4 30473099 [A/C] rs1473094 4 30476154 [T/C] rs4692459 4 30478873 [A/G] rs4692090 4 30478965 [A/G] rs1553923 4 30484155 [A/C] rs9291543 4 30490490 [T/C] rs1588610 4 30508931 [A/G] rs13147511 4 30510223 [T/C] rs6812829 4 30511492 [T/C] rs1818442 4 30533811 [T/G] rs10049961 4 30534141 [T/C] rs1588614 4 30535299 [T/C] rs6846798 4 30536779 [T/C] rs2018994 4 30536826 [T/C] rs11727470 4 30544014 [A/G] rs12374418 4 30550919 [A/C] rs1512148 4 30556489 [T/C] rs1398181 4 30559836 [A/G] rs7678701 4 30560475 [A/G] rs10014617 4 30569583 [A/G] rs10028617 4 30569852 [T/C] rs7682155 4 30572878 [A/G] rs6847353 4 30574424 [T/C] rs1512160 4 30575515 [A/C] rs10028403 4 30575592 [T/G] rs10019706 4 30576335 [A/G] rs10517209 4 30577159 [T/C] rs13131444 4 30578175 [A/G] rs7687443 4 30579183 [A/G] rs7690439 4 30591791 [T/C] rs10019377 4 30597133 [T/C] rs9994236 4 30599882 [A/G] rs10939307 4 30610801 [A/G] rs12374222 4 30612026 [A/G] rs13115431 4 30613111 [T/C] rs901457 4 30614201 [A/G] rs12511839 4 30625276 [A/G] rs10939310 4 30629161 [A/G] rs7694762 4 30629389 [T/G] rs767478 4 30630382 [A/G] rs1906110 4 30633334 [T/C] rs4692473 4 30633835 [A/C] rs10015964 4 30639658 [A/G] rs13109270 4 30640272 [T/C] rs13115999 4 30641018 [T/C] rs6448713 4 30645543 [A/G] rs6821889 4 30645986 [T/C] rs16883928 4 30647182 [T/C] rs10030792 4 30649753 [A/G] rs6848945 4 30649819 [T/C] rs1486785 4 30652381 [T/C] rs6820780 4 30658535 [A/G] rs7658553 4 30666011 [T/C] rs13146789 4 30668535 [T/G] rs7654222 4 30669244 [T/C] rs747606 4 30669328 [T/C] rs7654418 4 30669388 [T/C] rs4277739 4 30671050 [A/C] rs7671654 4 30677046 [T/C] rs4692481 4 30691142 [T/G] rs4270551 4 30703243 [A/C] rs6855728 4 30710951 [T/C] rs12163915 4 30711230 [A/C] rs9291546 4 30718333 [A/G] rs12648636 4 30720632 [A/G] rs1047012 4 30725696 [A/G] NM_032456,NM_032457,NM_002589,NM_001173523 PCDH7,PCDH7,PCDH7,PCDH7 EXON Synonymous_V884V,Synonymous_V884V,Synonymous_V884V,Synonymous_V884V rs977931 4 30725987 [A/G] NM_032456,NM_032457,NM_002589,NM_001173523 PCDH7,PCDH7,PCDH7,PCDH7 EXON Synonymous_R981R,Synonymous_R981R,Synonymous_R981R,Synonymous_R981R rs2121658 4 30727233 [A/C] NM_032457,NM_002589,NM_001173523 PCDH7,PCDH7,PCDH7 Silent,Silent,Silent rs3775331 4 30728507 [T/C] NM_032457,NM_002589,NM_001173523 PCDH7,PCDH7,PCDH7 Silent,Silent,Silent rs3756025 4 30732274 [T/G] NM_032457,NM_002589,NM_001173523 PCDH7,PCDH7,PCDH7 Silent,Silent,Silent rs13105058 4 30736301 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs13111136 4 30736724 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs28420079 4 30737146 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs9291547 4 30749654 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs10003467 4 30752187 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs4380480 4 30767675 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs2121659 4 30785307 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs10013155 4 30794339 [T/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs4557224 4 30796107 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs2310224 4 30799850 [T/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs11732391 4 30807244 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs1348923 4 30810421 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs6847642 4 30810487 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs6812005 4 30811774 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs2121656 4 30814699 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs13138213 4 30815089 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs9993447 4 30817994 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs16884138 4 30827429 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs4619848 4 30827805 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs4692105 4 30828781 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs11724608 4 30830285 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs1447373 4 30832836 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs13140818 4 30837989 [A/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs1447370 4 30838752 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs1345148 4 30843533 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs6816969 4 30845667 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs16884199 4 30861403 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs10517220 4 30862363 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs13150968 4 30864486 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs10001740 4 30866392 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs4422383 4 30872098 [A/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs4269140 4 30874445 [T/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs11937211 4 30893493 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs11735048 4 30922078 [A/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs4293757 4 30943209 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs12508739 4 30947714 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs7659873 4 30970763 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs10027212 4 30976208 [T/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs6822671 4 30977401 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs6847898 4 30984320 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs7696734 4 30987395 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs13102223 4 30991363 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs10004523 4 30992250 [A/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs6448730 4 30996811 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs10939325 4 30997909 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs4132132 4 31001301 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs4692497 4 31005966 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs7696101 4 31016990 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs10939326 4 31025354 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs10003973 4 31032608 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs6837499 4 31037602 [A/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs7661111 4 31059015 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs16884307 4 31068185 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs954103 4 31071934 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs6820873 4 31077545 [A/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs3947332 4 31080447 [A/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs2221128 4 31095678 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs9999226 4 31095854 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs2201945 4 31100499 [A/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs10010739 4 31104796 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs11935515 4 31110337 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs3857021 4 31117942 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs16884372 4 31122429 [T/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs1392057 4 31123849 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs11937565 4 31124325 [A/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs10517226 4 31129958 [T/C] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs12507539 4 31135624 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 Silent,Silent rs16884422 4 31146115 [A/G] NM_032457,NM_001173523 PCDH7,PCDH7 EXON Silent,Silent rs16884451 4 31148688 [T/C] rs16884471 4 31150900 [A/C] rs16884473 4 31151060 [T/C] rs1463844 4 31157943 [A/C] rs1353854 4 31158565 [T/C] rs13340304 4 31162659 [A/G] rs6833999 4 31166902 [T/G] rs11938193 4 31170286 [A/G] rs6448753 4 31183845 [A/G] NR_125935 LINC02497 Silent rs2036247 4 31187185 [T/C] NR_125935 LINC02497 Silent rs6828314 4 31187606 [T/C] NR_125935 LINC02497 Silent rs17779235 4 31190168 [T/G] NR_125935 LINC02497 Silent rs6448754 4 31196514 [T/C] NR_125935 LINC02497 Silent rs11930062 4 31200828 [A/G] NR_125935 LINC02497 Silent rs11933756 4 31209228 [A/G] NR_125935 LINC02497 Silent rs1463842 4 31209875 [A/G] NR_125935 LINC02497 Silent rs11937481 4 31211978 [A/G] NR_125935 LINC02497 Silent rs6849452 4 31216675 [A/G] rs1499466 4 31217251 [T/C] rs17723773 4 31217377 [T/G] rs4591553 4 31217902 [T/C] rs12331227 4 31218368 [T/C] rs6821356 4 31219796 [T/C] rs6820490 4 31230228 [A/G] rs10001703 4 31232183 [T/G] rs951011 4 31232890 [A/C] rs17724390 4 31233979 [A/C] rs1392056 4 31235824 [T/C] rs10002340 4 31249967 [A/C] rs12640774 4 31250706 [T/C] rs4321596 4 31254765 [T/C] rs4624622 4 31254780 [T/C] rs6811209 4 31262043 [T/C] rs11735188 4 31271863 [T/C] rs6815632 4 31277116 [A/G] rs4441721 4 31302011 [A/G] rs9291566 4 31306116 [A/G] rs11935585 4 31316264 [A/C] rs4303942 4 31319406 [A/G] rs1156910 4 31322470 [A/G] rs16884777 4 31323469 [A/G] rs10029975 4 31324283 [A/C] rs10025805 4 31333616 [T/C] rs6820923 4 31334007 [T/G] rs10517227 4 31335371 [T/C] rs1991343 4 31336704 [T/C] rs13128378 4 31338387 [A/C] rs7683447 4 31338743 [A/C] rs13135059 4 31339067 [A/G] rs6848921 4 31340010 [A/G] rs10033651 4 31341126 [T/C] rs1426985 4 31341384 [A/C] rs6827566 4 31343877 [A/G] rs7695413 4 31346154 [A/C] rs10033276 4 31346517 [A/G] rs4692508 4 31354090 [A/C] rs933954 4 31357836 [T/G] rs16884897 4 31358792 [T/C] rs2081665 4 31360789 [T/C] rs4692511 4 31364659 [T/C] rs10017667 4 31365792 [A/C] rs16884929 4 31366504 [T/C] rs6854032 4 31367210 [T/C] rs7677024 4 31367687 [A/G] rs11943523 4 31368170 [A/G] rs16884956 4 31368529 [T/G] rs10000543 4 31370788 [T/C] rs13140925 4 31375593 [A/G] rs1834709 4 31377722 [A/G] rs1834707 4 31377963 [T/C] rs1834705 4 31381690 [T/G] rs13140921 4 31382580 [A/G] rs6448771 4 31397618 [A/G] rs7689511 4 31405546 [T/C] rs7700198 4 31413759 [A/G] rs9684021 4 31415607 [T/C] rs16885042 4 31417540 [T/C] rs10517228 4 31423493 [A/G] rs1966546 4 31427408 [T/C] rs6825297 4 31436863 [A/C] rs454864 4 31447488 [A/G] rs409441 4 31448474 [A/G] rs397718 4 31448956 [T/C] rs424917 4 31456071 [A/G] rs433149 4 31457293 [T/C] rs404532 4 31461728 [A/G] rs16885247 4 31474310 [A/G] rs401044 4 31480930 [A/C] rs11726010 4 31481063 [A/G] rs2925543 4 31489510 [T/C] rs2912616 4 31489663 [A/G] rs446149 4 31490705 [A/G] rs452052 4 31494159 [A/G] rs4145381 4 31496548 [A/G] rs6816371 4 31508206 [A/C] NR_149121,NR_149122 LINC02501,LINC02501 EXON Silent,Silent rs10002573 4 31510999 [T/C] NR_149121,NR_149122 LINC02501,LINC02501 Silent,Silent rs6448778 4 31513263 [A/C] NR_149121,NR_149122 LINC02501,LINC02501 Silent,Silent rs10805304 4 31525698 [A/C] NR_149121,NR_149122 LINC02501,LINC02501 Silent,Silent rs1598684 4 31531497 [T/C] NR_149121,NR_149122 LINC02501,LINC02501 Silent,Silent rs1456746 4 31540596 [A/G] NR_149121,NR_149122 LINC02501,LINC02501 Silent,Silent rs1379127 4 31559379 [T/C] NR_149121 LINC02501 Silent rs7678026 4 31581408 [T/C] rs7656200 4 31590431 [A/G] rs6830965 4 31598534 [A/G] rs10428460 4 31599070 [A/C] rs6813009 4 31611630 [T/G] rs7690924 4 31613185 [A/G] rs6811437 4 31619950 [A/C] rs1397500 4 31621421 [A/G] rs10939353 4 31629820 [A/G] rs1510801 4 31636008 [A/G] rs11932796 4 31641279 [T/G] rs9992305 4 31643126 [A/C] rs11944702 4 31660739 [T/C] rs1510806 4 31661814 [T/G] rs1510810 4 31665898 [T/C] rs16885609 4 31666014 [T/C] rs9999931 4 31676985 [T/C] rs4692118 4 31678181 [A/G] rs6853792 4 31684334 [T/C] rs6831283 4 31684540 [T/C] rs4692526 4 31698470 [A/G] rs16885692 4 31698958 [A/G] rs16885694 4 31700291 [T/G] rs2192531 4 31709060 [A/G] rs12643894 4 31709237 [T/C] rs13133369 4 31712529 [T/C] rs7667509 4 31715497 [T/C] rs16885723 4 31715825 [A/C] rs10489008 4 31718284 [A/C] rs10489007 4 31718445 [A/C] rs17595220 4 31721265 [T/C] rs9990632 4 31739254 [T/C] rs1157893 4 31744052 [A/G] rs10002958 4 31744915 [A/G] rs11946605 4 31746895 [A/G] rs1861127 4 31754447 [A/G] rs13136356 4 31758426 [T/C] rs17603187 4 31766080 [A/G] rs7661647 4 31766707 [T/C] rs7682874 4 31770464 [A/G] rs965954 4 31778484 [A/G] rs887918 4 31779135 [A/G] rs2041704 4 31780030 [A/G] rs17604071 4 31780528 [T/C] rs988466 4 31784698 [T/G] rs2310395 4 31785073 [A/G] rs10029539 4 31791952 [T/C] rs13134705 4 31808700 [T/C] rs28493679 4 31811755 [T/C] rs7658061 4 31849223 [T/C] rs6553979 4 31849408 [A/G] rs6554033 4 31855487 [A/C] rs1523145 4 31863889 [T/C] rs6827011 4 31867207 [A/G] rs13144359 4 31872574 [T/C] rs7680258 4 31890470 [T/C] rs10007812 4 31893113 [A/G] rs6813096 4 31895086 [A/G] rs10006001 4 31901631 [T/G] rs11722381 4 31907596 [A/G] rs10027346 4 31909356 [A/G] rs17742652 4 31910970 [A/G] rs2140306 4 31923203 [T/C] rs7694314 4 31927635 [T/C] rs7690576 4 31930676 [A/G] rs10517232 4 31935746 [T/C] rs7657134 4 31939594 [T/C] rs10050320 4 31941906 [A/G] rs4446365 4 31944649 [T/C] rs1581453 4 31948000 [T/C] rs1523171 4 31950589 [A/C] rs6816397 4 31950876 [A/G] rs1523174 4 31951574 [A/G] rs7683244 4 31966758 [T/G] rs1523160 4 31967738 [T/C] rs9994107 4 31970683 [T/C] rs1879999 4 31987807 [T/C] rs7678075 4 31991952 [A/G] rs17806054 4 32004256 [T/C] NR_125936 LINC02506 Silent rs6553983 4 32005439 [T/C] NR_125936 LINC02506 Silent rs1996886 4 32006648 [T/C] NR_125936 LINC02506 Silent rs2037549 4 32017834 [T/C] NR_125936,NR_134682 LINC02506,LOC105377651 Silent,Silent rs10016652 4 32020581 [T/C] NR_125936,NR_134682 LINC02506,LOC105377651 Silent,Silent rs4502723 4 32051793 [T/G] NR_125936 LINC02506 Silent rs10024879 4 32071518 [A/G] NR_125936 LINC02506 Silent rs6825247 4 32095002 [A/G] NR_125936 LINC02506 Silent rs4568279 4 32101805 [A/C] NR_125936 LINC02506 Silent rs10017595 4 32114385 [A/G] NR_125936 LINC02506 Silent rs12645721 4 32122682 [A/G] NR_125936 LINC02506 Silent rs10016697 4 32124034 [A/G] NR_125936 LINC02506 Silent rs6554007 4 32125671 [T/G] NR_125936 LINC02506 Silent rs6419997 4 32129472 [A/G] NR_125936 LINC02506 Silent rs10011864 4 32143073 [A/G] NR_125936 LINC02506 Silent rs13131255 4 32162911 [A/C] rs7686517 4 32162926 [T/C] rs3923313 4 32167598 [A/G] rs1491226 4 32174131 [A/G] rs4862911 4 32186096 [T/C] rs834461 4 32190693 [T/C] rs4862912 4 32194466 [A/G] rs17080898 4 32194941 [A/G] rs17080902 4 32196347 [A/C] rs6816384 4 32196630 [A/G] rs7656532 4 32200425 [T/C] rs12509554 4 32201551 [T/G] rs1388281 4 32206490 [A/G] rs4565120 4 32209922 [T/C] rs7699259 4 32222974 [A/G] rs7699029 4 32225480 [A/C] rs1417055 4 32226350 [A/G] rs17080946 4 32227281 [T/C] rs7681502 4 32240417 [A/C] rs731196 4 32244696 [T/C] rs17081065 4 32249490 [T/C] rs4596286 4 32252137 [A/G] rs12503077 4 32252530 [T/C] rs9654318 4 32259468 [T/C] rs766436 4 32259822 [T/C] rs10004675 4 32260388 [A/G] rs634360 4 32262563 [A/G] rs17081112 4 32264911 [A/G] rs1670754 4 32264997 [A/G] rs10517241 4 32265355 [T/C] rs11734603 4 32268382 [A/G] rs10016605 4 32269494 [T/G] rs923669 4 32270703 [A/G] rs4142790 4 32271390 [A/G] rs17081139 4 32271663 [T/G] rs1472088 4 32273315 [A/G] rs13139441 4 32275756 [T/C] rs17081177 4 32280812 [A/G] rs11133199 4 32292534 [A/G] rs6824483 4 32300373 [A/G] rs13102286 4 32300636 [T/C] rs1116083 4 32307437 [T/C] rs10049820 4 32313387 [T/C] rs902654 4 32315731 [A/G] rs4314329 4 32316663 [T/C] rs13119336 4 32318535 [A/G] rs17081264 4 32318797 [T/C] rs1377892 4 32323374 [T/C] rs2897006 4 32329911 [A/G] rs2219113 4 32342392 [T/C] rs2061001 4 32345711 [A/G] rs763366 4 32356997 [A/G] rs9654325 4 32368307 [T/G] rs1377896 4 32373939 [A/C] rs1349859 4 32380665 [A/G] rs9998298 4 32381251 [T/C] rs1349860 4 32384828 [T/C] rs1454310 4 32398607 [A/G] rs17313860 4 32407960 [T/C] rs6854744 4 32419013 [A/G] rs6811698 4 32423954 [A/G] rs4862924 4 32425677 [A/G] rs6850712 4 32426634 [A/C] rs1466230 4 32428642 [A/G] rs10015890 4 32429986 [T/G] rs733046 4 32432985 [T/C] rs12503381 4 32435842 [T/G] rs11133215 4 32437731 [A/C] rs10007799 4 32446724 [A/G] rs4862928 4 32449832 [T/C] rs10007938 4 32452973 [A/G] rs10006044 4 32461577 [A/G] rs11930703 4 32473028 [A/G] rs4862932 4 32477273 [T/C] rs4298181 4 32481587 [A/C] rs12500423 4 32483506 [A/G] rs4413448 4 32487731 [A/G] rs17081424 4 32495165 [A/G] rs11732748 4 32496303 [T/G] rs17081443 4 32497865 [T/C] rs10461348 4 32498066 [A/G] rs12510113 4 32498077 [T/G] rs961422 4 32501462 [A/C] rs1584155 4 32509904 [A/G] rs6554028 4 32515265 [T/G] rs7657618 4 32521580 [T/C] rs7699138 4 32525781 [T/C] rs12649655 4 32526020 [A/C] rs12500172 4 32527996 [T/C] rs12648469 4 32529449 [T/C] rs11944364 4 32530706 [T/C] rs11941142 4 32547580 [T/C] rs17081565 4 32558700 [A/G] rs7680003 4 32577729 [T/C] rs7695359 4 32577958 [T/C] rs11735577 4 32580240 [A/G] rs13129687 4 32580391 [T/C] rs1373869 4 32581594 [T/C] rs2121001 4 32582163 [T/G] rs1822927 4 32588326 [T/C] rs1037079 4 32590048 [T/C] rs10015029 4 32590516 [A/G] rs11936953 4 32592691 [A/G] rs6841893 4 32593812 [T/C] rs993054 4 32594107 [A/C] rs11947379 4 32596378 [A/G] rs1348664 4 32609134 [A/C] rs1838626 4 32617549 [A/C] rs4862943 4 32623768 [A/G] rs6840469 4 32626153 [A/C] rs6855223 4 32626298 [A/G] rs755773 4 32628884 [T/C] rs1900085 4 32629687 [A/C] rs9884918 4 32633208 [T/C] rs7675897 4 32635777 [A/G] rs11133230 4 32640520 [A/G] rs1822923 4 32640624 [A/C] rs13112668 4 32653512 [A/G] rs6826047 4 32662406 [A/G] rs6554041 4 32682680 [T/C] rs6842905 4 32682696 [A/G] rs6812552 4 32686781 [T/C] rs4547836 4 32688362 [T/C] rs10025667 4 32695806 [T/C] rs4862896 4 32707959 [T/C] rs4862897 4 32728359 [T/C] rs4353947 4 32729725 [A/G] rs6814336 4 32738289 [A/C] rs9968428 4 32745997 [T/C] rs12715993 4 32749519 [A/C] rs4130313 4 32773352 [A/G] rs11940854 4 32793497 [T/C] rs4340831 4 32798521 [T/C] rs7663866 4 32801473 [A/G] rs9992839 4 32803900 [A/G] rs13110509 4 32813842 [A/G] rs7665163 4 32823936 [T/C] rs7438388 4 32851818 [A/G] rs6812308 4 32855573 [A/C] rs7439281 4 32862457 [A/G] rs12651213 4 32866929 [A/G] rs9993494 4 32877827 [T/G] rs13123433 4 32902806 [T/G] rs7659735 4 32931940 [T/G] rs6827177 4 32932415 [T/C] rs7697063 4 32947309 [T/G] rs7438285 4 32952490 [A/G] rs7667876 4 32953000 [T/C] rs9996183 4 32958989 [A/G] rs10033556 4 32962030 [A/G] rs7437969 4 32988370 [T/C] rs16988491 4 32996575 [A/G] rs16988494 4 32997372 [T/C] rs6816693 4 32999592 [A/C] rs1448280 4 33000930 [T/C] rs6832554 4 33011731 [T/C] rs6531310 4 33012314 [T/C] rs6531322 4 33021328 [T/C] rs1349084 4 33030781 [A/G] rs6857336 4 33034172 [A/G] rs6822098 4 33070286 [T/G] rs876637 4 33090656 [A/G] rs6827600 4 33091459 [A/G] rs16988606 4 33098368 [T/C] rs16988609 4 33106320 [T/C] rs1584385 4 33120543 [A/C] rs3928486 4 33152713 [T/C] rs10856819 4 33191579 [T/C] rs6846113 4 33194457 [A/G] rs11735365 4 33200267 [T/C] rs11096807 4 33200295 [T/C] rs1373053 4 33203015 [T/C] rs10517270 4 33203140 [A/G] rs7680581 4 33206192 [A/G] rs7695326 4 33217636 [A/C] rs2586001 4 33225232 [A/G] rs2687427 4 33225866 [T/C] rs2586005 4 33229984 [A/G] rs2586009 4 33235506 [T/C] rs2687463 4 33240041 [A/G] rs2585909 4 33247495 [T/C] rs6853605 4 33262073 [A/G] rs2687412 4 33269322 [A/C] rs6814031 4 33274438 [T/C] rs2687386 4 33288145 [A/C] rs2687402 4 33304013 [A/G] rs1443207 4 33305495 [A/G] rs2687410 4 33308646 [A/G] rs3098933 4 33309890 [A/C] rs883617 4 33318082 [A/G] rs11722181 4 33354946 [A/C] rs10027353 4 33377677 [T/C] rs1506252 4 33378232 [A/G] rs16988955 4 33380852 [A/G] rs6815807 4 33382909 [A/C] rs1605208 4 33386368 [A/G] rs969744 4 33411515 [T/C] rs6824666 4 33439168 [T/C] rs6827883 4 33444407 [T/C] rs2062990 4 33461734 [A/G] rs10517277 4 33466803 [A/C] rs7665332 4 33487061 [A/G] rs10517282 4 33545170 [A/G] rs10025535 4 33581520 [A/G] rs6811211 4 33582784 [T/C] rs1598194 4 33599429 [T/C] rs1454609 4 33616414 [A/C] rs16989059 4 33628239 [T/C] rs1598193 4 33640864 [A/G] rs10025343 4 33641476 [A/G] rs10517288 4 33645806 [A/C] rs1378043 4 33653124 [A/G] rs717947 4 33653757 [T/C] rs16989144 4 33657798 [T/C] rs6830471 4 33658459 [A/G] rs1902083 4 33695359 [T/G] rs6847997 4 33700983 [A/C] rs11934157 4 33723913 [A/G] rs9997046 4 33726506 [A/G] rs13111438 4 33745441 [T/C] rs7684329 4 33747424 [T/C] rs6531772 4 33756410 [T/C] rs9306981 4 33762750 [T/C] rs12645598 4 33766955 [T/C] rs16989244 4 33784564 [A/G] rs13104973 4 33810391 [A/C] rs16995877 4 33840835 [A/G] rs6531287 4 33879862 [A/G] rs10008587 4 33883366 [T/C] rs13120249 4 33910151 [A/G] NR_125902 LOC101928622 Silent rs10009545 4 33944748 [A/G] NR_125902 LOC101928622 Silent rs10002222 4 33991474 [T/C] NR_125902 LOC101928622 Silent rs10007637 4 34000455 [A/G] NR_125902 LOC101928622 Silent rs10004776 4 34012943 [T/C] NR_125902 LOC101928622 Silent rs12645236 4 34015067 [T/C] NR_125902 LOC101928622 Silent rs13106616 4 34043420 [A/G] rs7698333 4 34049908 [A/G] rs6844408 4 34069989 [T/C] rs6852667 4 34074079 [A/G] rs13149553 4 34110314 [T/C] rs7439164 4 34129758 [A/C] NR_147183,NR_147184 LINC02484,LINC02484 Silent,Silent rs13113036 4 34135538 [A/C] NR_147183,NR_147184 LINC02484,LINC02484 Silent,Silent rs7654957 4 34149964 [T/C] NR_147183,NR_147184 LINC02484,LINC02484 Silent,Silent rs36118373 4 34159800 [A/G] NR_147183,NR_147184 LINC02484,LINC02484 Silent,Silent rs10034465 4 34195504 [A/G] NR_147183,NR_147184 LINC02484,LINC02484 Silent,Silent rs6531299 4 34195693 [T/C] NR_147183,NR_147184 LINC02484,LINC02484 Silent,Silent rs9968275 4 34231055 [A/C] NR_147183,NR_147184 LINC02484,LINC02484 Silent,Silent rs2217015 4 34303751 [T/C] rs7656700 4 34305397 [T/C] rs16989413 4 34323177 [T/C] rs1425503 4 34348697 [T/C] rs1425502 4 34348739 [A/G] rs6849339 4 34356554 [A/G] rs4859319 4 34370370 [A/G] rs7665973 4 34397464 [T/C] rs10017869 4 34398073 [A/C] rs10008623 4 34410712 [A/C] rs6822676 4 34413064 [A/G] rs2217013 4 34415056 [A/G] rs6855693 4 34451311 [A/G] rs10517312 4 34462800 [A/G] rs1480978 4 34466283 [T/C] rs10517316 4 34472258 [T/G] rs16989731 4 34473606 [A/C] rs10011680 4 34478767 [T/G] rs11096735 4 34484035 [T/C] rs10019000 4 34488990 [T/C] rs12647612 4 34490327 [A/G] rs1904897 4 34492968 [A/G] rs6817183 4 34498265 [A/C] rs6858830 4 34500856 [A/G] rs6531318 4 34501955 [A/G] rs6847787 4 34507327 [T/G] rs10004976 4 34510322 [A/G] rs16989906 4 34516037 [T/C] rs16989912 4 34520176 [T/C] rs10024915 4 34526858 [A/G] rs7693554 4 34529796 [A/G] rs1380341 4 34534283 [T/C] rs10001592 4 34539188 [A/G] rs1380337 4 34540177 [A/G] rs16989950 4 34541266 [T/C] rs13140884 4 34542371 [T/C] rs1459452 4 34544661 [A/G] rs2360784 4 34545919 [T/G] rs4428312 4 34547031 [A/G] rs1842529 4 34553989 [T/C] rs6829919 4 34557595 [A/C] rs16989994 4 34573079 [A/G] rs4521368 4 34582188 [T/C] rs16990029 4 34587422 [T/C] rs1459455 4 34595042 [T/C] rs10023150 4 34595824 [T/C] rs6846061 4 34607713 [A/G] rs10032489 4 34613756 [T/C] rs2054575 4 34618584 [A/G] rs1599110 4 34642826 [T/C] rs898274 4 34649878 [T/C] rs2125679 4 34662438 [T/G] rs16990149 4 34681271 [T/G] rs11935755 4 34686182 [A/G] rs4317222 4 34692953 [A/G] rs13119900 4 34693304 [A/G] rs1912844 4 34710850 [T/C] rs11096741 4 34711183 [T/C] rs1511859 4 34716594 [A/G] rs16990210 4 34720226 [T/C] rs953483 4 34723455 [T/C] rs10019384 4 34725270 [T/C] rs16990230 4 34726596 [T/C] rs13434494 4 34731172 [T/C] rs6855792 4 34738785 [T/C] rs11944699 4 34749635 [A/G] rs13106336 4 34756057 [T/C] rs10012250 4 34763475 [A/G] rs6849320 4 34765595 [T/C] rs6855391 4 34772226 [T/C] rs16990346 4 34772494 [T/C] rs10155317 4 34773861 [A/C] rs10019802 4 34829761 [A/C] rs7678322 4 34831143 [T/C] rs1706226 4 34841364 [T/C] rs9884148 4 34846207 [T/C] rs16990385 4 34847300 [T/C] rs16990396 4 34848404 [T/C] rs2055931 4 34852124 [T/C] rs16990420 4 34855432 [T/C] rs16990438 4 34858160 [A/G] rs10021358 4 34863594 [T/C] rs7670648 4 34867696 [A/G] rs1706212 4 34869949 [A/G] rs2668134 4 34871955 [T/C] rs1912842 4 34872926 [A/C] rs13102063 4 34873669 [A/G] rs1617678 4 34883393 [A/G] rs3113627 4 34883601 [T/C] rs9998396 4 34900365 [T/C] rs2124423 4 34902615 [T/C] rs9306919 4 34910052 [T/C] rs11730487 4 34913289 [A/G] rs12163863 4 34916207 [A/G] rs11736165 4 34917769 [A/G] rs13137372 4 34928521 [T/C] rs2370151 4 34941651 [T/C] rs11729074 4 34955378 [T/C] rs16990538 4 34963574 [A/C] rs1455920 4 34964349 [T/C] rs996913 4 34968968 [T/C] rs2370152 4 34969327 [T/C] rs874936 4 34973964 [A/G] rs10020332 4 34978685 [T/C] rs16990592 4 34983045 [A/G] rs921853 4 34984841 [T/C] rs1350117 4 34990357 [A/G] rs16990620 4 34992661 [A/G] rs16990641 4 35009208 [T/C] rs6850734 4 35019180 [T/C] rs6839051 4 35026277 [A/C] rs10011962 4 35033504 [A/G] rs11930898 4 35034577 [T/C] rs11937269 4 35039400 [T/C] rs7691503 4 35041483 [T/C] rs2054129 4 35047017 [T/C] rs4519816 4 35054077 [A/G] rs12498679 4 35065154 [T/C] rs7689990 4 35066604 [T/G] rs11934327 4 35068091 [T/G] rs7654262 4 35073382 [T/C] rs4859335 4 35073545 [A/G] rs7689165 4 35079586 [A/G] rs7655946 4 35098359 [T/C] rs6845541 4 35101471 [T/C] rs11930548 4 35104571 [T/C] rs13134303 4 35105267 [A/G] rs1480976 4 35113694 [T/G] rs10020480 4 35119011 [A/C] rs11943039 4 35119704 [T/C] rs7660410 4 35126537 [T/C] rs10001135 4 35127797 [T/G] rs6823854 4 35128162 [A/G] rs9996939 4 35131703 [T/C] rs1023933 4 35149660 [A/C] rs11943194 4 35150193 [T/C] rs13114204 4 35151237 [T/C] rs2035355 4 35156419 [T/C] rs1994012 4 35156806 [T/G] rs11934913 4 35161173 [A/G] rs4629470 4 35166363 [T/C] rs1383561 4 35166628 [A/C] rs1480967 4 35168725 [T/C] rs1600683 4 35175065 [T/C] rs2127853 4 35175249 [T/C] rs1480974 4 35176533 [A/G] rs16990845 4 35177867 [T/C] rs11934931 4 35183361 [T/C] rs10015056 4 35183698 [A/G] rs11938895 4 35186912 [T/C] rs2127850 4 35195922 [T/C] rs3937773 4 35214648 [T/C] rs6531347 4 35218959 [T/C] rs10034866 4 35224429 [T/C] rs7691687 4 35224530 [T/C] rs7687153 4 35226451 [T/C] rs10017113 4 35230371 [A/G] rs6816663 4 35235185 [T/G] rs12643815 4 35235257 [T/C] rs10016775 4 35236015 [A/G] rs13117747 4 35237089 [A/G] rs13140030 4 35239619 [T/C] rs7686175 4 35248847 [A/G] rs4615191 4 35252743 [A/G] rs4543137 4 35256839 [A/G] rs10032114 4 35264817 [A/G] rs11934682 4 35268816 [T/C] rs9306924 4 35269594 [T/C] rs16990885 4 35277250 [A/G] rs7676113 4 35283162 [T/C] rs11096770 4 35283461 [T/C] rs4501247 4 35285050 [A/C] rs6837097 4 35295899 [T/C] rs10033446 4 35299216 [T/C] rs10000487 4 35299287 [A/G] rs16990899 4 35301330 [T/C] rs2375438 4 35317313 [T/C] rs10021051 4 35319420 [T/C] rs6833760 4 35322466 [T/C] rs9999521 4 35328365 [A/C] rs7698422 4 35328610 [T/C] rs11934837 4 35329616 [A/G] rs2078217 4 35331535 [T/G] rs4859348 4 35331719 [A/G] rs13143446 4 35333439 [T/G] rs7662185 4 35348509 [A/C] rs2028445 4 35349031 [T/C] rs1372156 4 35360452 [A/C] rs16990994 4 35371360 [A/G] rs437943 4 35372098 [T/C] rs317068 4 35374166 [A/C] rs12640154 4 35390613 [T/C] rs16991064 4 35393192 [A/G] rs12642609 4 35401416 [A/G] rs317014 4 35404286 [A/G] rs317027 4 35425629 [T/C] rs3098733 4 35426994 [T/C] rs16991102 4 35429711 [T/C] rs1588755 4 35433331 [A/G] rs317042 4 35437344 [T/C] rs317053 4 35445068 [T/C] rs13131923 4 35454737 [T/C] rs10213456 4 35457442 [T/C] rs4859360 4 35468984 [T/C] rs7681453 4 35472712 [A/G] rs1022261 4 35476300 [A/C] rs13152634 4 35501491 [A/G] rs6841237 4 35506681 [T/C] rs13123633 4 35514182 [A/G] rs7694691 4 35528798 [T/C] rs7694515 4 35538439 [A/G] rs10517352 4 35554589 [T/G] rs1863309 4 35570040 [A/C] rs11936942 4 35583122 [A/C] rs7656274 4 35588460 [A/G] rs2162098 4 35595493 [A/G] rs7667040 4 35604709 [A/G] rs6836342 4 35618590 [T/C] rs1425460 4 35630846 [A/G] rs1019641 4 35654641 [A/G] rs12640371 4 35668267 [A/C] rs10517350 4 35673557 [T/C] rs6531383 4 35676909 [T/C] rs10517354 4 35689019 [A/C] rs10517355 4 35689166 [A/G] rs11933413 4 35696434 [A/G] rs2375563 4 35698696 [T/C] rs6824653 4 35700161 [T/G] rs1596575 4 35717920 [A/G] rs1596577 4 35724618 [A/G] rs1822676 4 35726689 [A/C] rs1444372 4 35727026 [T/C] rs1822674 4 35731201 [A/G] rs1373489 4 35733449 [A/C] rs9997781 4 35734550 [A/G] rs986240 4 35739721 [T/G] rs11731044 4 35740465 [A/G] rs5011112 4 35751033 [T/C] rs2889115 4 35765765 [A/G] rs11947034 4 35772231 [A/C] rs16991470 4 35780805 [A/C] rs987863 4 35782245 [T/C] rs11096782 4 35790610 [A/G] rs13140299 4 35795133 [T/C] rs2375567 4 35796678 [T/C] rs1867476 4 35801429 [T/G] rs12641153 4 35803591 [T/C] rs6854185 4 35806331 [A/G] rs6835544 4 35807078 [T/C] rs7689870 4 35808371 [A/C] rs6849048 4 35808971 [T/C] rs11725995 4 35812208 [A/C] rs6851284 4 35814428 [T/G] rs1020337 4 35814521 [A/C] rs4833120 4 35839822 [A/G] rs1368610 4 35846086 [A/G] rs10003970 4 35859953 [A/G] rs16991611 4 35869643 [A/G] rs16988240 4 35870854 [A/G] rs1465712 4 35873240 [A/G] rs3943785 4 35873980 [T/C] rs1807199 4 35874310 [T/G] rs16991635 4 35884368 [A/G] rs7676055 4 35885873 [A/G] rs10470868 4 35892598 [T/C] rs1433429 4 35899687 [A/G] rs749064 4 35903030 [T/C] rs2005025 4 35903310 [T/C] rs753921 4 35903499 [T/C] rs753920 4 35903624 [T/C] rs1433430 4 35904938 [T/C] rs1714034 4 35908009 [A/G] rs6826926 4 35909078 [T/C] rs1655058 4 35911736 [T/C] rs11734481 4 35912580 [A/G] rs1030700 4 35912892 [A/G] rs1030702 4 35914787 [A/G] rs1836080 4 35916584 [T/C] rs12512900 4 35918905 [T/C] rs1714058 4 35919345 [A/G] rs4001124 4 35921123 [A/G] rs16991684 4 35926948 [A/G] rs4832855 4 35930651 [T/C] rs7668984 4 35930794 [T/C] rs7677061 4 35933237 [T/C] rs1433439 4 35934885 [A/G] rs16991732 4 35935826 [A/G] rs11736705 4 35944165 [T/C] rs1655085 4 35958133 [A/G] rs1655036 4 35967246 [A/G] rs17447579 4 35976090 [T/G] rs1622680 4 35976738 [T/C] rs6834483 4 35983111 [T/C] rs9992603 4 35992101 [A/G] rs12502892 4 35995064 [T/G] rs7439956 4 35996495 [T/G] rs11096793 4 36000044 [A/G] rs6815215 4 36004792 [T/C] rs6840079 4 36004833 [A/C] rs13111222 4 36005220 [A/C] rs16991830 4 36005501 [A/C] rs1510656 4 36006393 [T/C] rs16991839 4 36007857 [A/G] NR_146893 ARAP2 EXON Silent rs10010285 4 36011362 [T/C] NR_146893 ARAP2 Silent rs2889174 4 36013141 [T/C] NR_146893 ARAP2 Silent rs2175322 4 36015016 [A/G] NR_146893 ARAP2 Silent rs1510653 4 36015133 [T/C] NR_146893 ARAP2 Silent rs7675286 4 36019457 [A/C] NR_146893 ARAP2 Silent rs6839195 4 36020436 [T/C] NR_146893 ARAP2 Silent rs2175324 4 36021366 [T/C] NR_146893 ARAP2 Silent rs872322 4 36021619 [A/G] NR_146893 ARAP2 Silent rs872321 4 36021678 [T/C] NR_146893 ARAP2 Silent rs13117501 4 36022360 [T/C] NR_146893 ARAP2 Silent rs11936026 4 36023112 [A/G] NR_146893 ARAP2 Silent rs11096795 4 36031024 [A/C] NR_146893 ARAP2 Silent rs12508463 4 36032942 [T/G] NR_146893 ARAP2 Silent rs6812127 4 36046629 [T/C] NR_146893 ARAP2 Silent rs997572 4 36048773 [A/G] NR_146893 ARAP2 Silent rs6851590 4 36048959 [A/C] NR_146893 ARAP2 Silent rs2048376 4 36052495 [T/G] NR_146893 ARAP2 Silent rs7676461 4 36055637 [T/C] NR_146893 ARAP2 Silent rs11947828 4 36059603 [T/C] NR_146893 ARAP2 EXON Silent rs13152028 4 36060318 [T/G] NR_146893 ARAP2 Silent rs2271810 4 36068286 [A/G] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 EXON Silent,Silent,Silent rs6851077 4 36076226 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs17493657 4 36076892 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs2136806 4 36081243 [A/G] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs4833069 4 36081878 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 EXON Silent,Missense_R1523Q,Silent rs16991904 4 36084658 [A/G] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs7670868 4 36085412 [A/G] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs6812542 4 36089558 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs13110947 4 36101738 [A/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs13137847 4 36101795 [A/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs1011288 4 36113030 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs4833107 4 36119788 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs1355331 4 36127176 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs7674819 4 36128192 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs4833119 4 36133342 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs7696339 4 36141187 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs4569781 4 36142906 [A/G] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs1510650 4 36144189 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs7680904 4 36151179 [A/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs17516600 4 36153128 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs7667582 4 36154555 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs13109154 4 36156910 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs4481252 4 36159118 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs2271330 4 36162923 [A/G] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs16991960 4 36163128 [A/G] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 EXON Silent,Synonymous_L740L,Silent rs2375743 4 36164500 [A/G] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs9985895 4 36184773 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs4394022 4 36211914 [A/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs6836152 4 36213761 [T/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs4472157 4 36220072 [A/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs13136192 4 36232191 [A/C] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs9992386 4 36238550 [A/G] NR_146893,NM_015230,NR_146894 ARAP2,ARAP2,ARAP2 Silent,Silent,Silent rs13103714 4 36250842 [A/G] NR_122079 LOC439933 Silent rs2055411 4 36260279 [T/G] NR_122079,NR_122080 LOC439933,LOC439933 Silent,Silent rs10049867 4 36267669 [T/C] NR_122079,NR_122080 LOC439933,LOC439933 Silent,Silent rs10004010 4 36271472 [A/G] NR_122079,NR_122080 LOC439933,LOC439933 Silent,Silent rs6821079 4 36273293 [A/G] NR_122079,NR_122080 LOC439933,LOC439933 Silent,Silent rs9306930 4 36282235 [A/G] rs16992033 4 36284941 [T/C] NM_001136536 DTHD1 Silent rs16992035 4 36285777 [A/G] NM_001136536,NM_001170700 DTHD1,DTHD1 EXON Silent,Missense_G26R rs6824507 4 36285929 [A/C] NM_001136536,NM_001170700 DTHD1,DTHD1 EXON Silent,Synonymous_V76V rs10517375 4 36290422 [A/G] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs1995319 4 36292018 [T/A] NM_001136536,NM_001170700 DTHD1,DTHD1 EXON Missense_V14D,Missense_V179D rs12498924 4 36293143 [A/G] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs12646644 4 36305264 [T/C] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs12507599 4 36310049 [T/C] NM_001136536,NM_001170700 DTHD1,DTHD1 EXON Missense_R387C,Missense_R552C rs10007998 4 36312202 [T/C] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs10025139 4 36313238 [T/C] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs17458763 4 36317259 [T/C] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs10003169 4 36317551 [A/G] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs9995922 4 36317970 [T/C] NM_001136536,NM_001170700 DTHD1,DTHD1 EXON Synonymous_S444S,Synonymous_S609S rs13131463 4 36323014 [T/C] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs13151413 4 36325988 [A/G] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs6832047 4 36326105 [T/C] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs16992066 4 36328939 [A/G] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs13129319 4 36329966 [A/G] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs7684936 4 36330976 [A/G] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs10517372 4 36331774 [A/C] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs16992086 4 36334157 [T/C] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs12508637 4 36334295 [A/G] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs16992087 4 36334933 [T/C] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs13140371 4 36336437 [T/G] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs7664826 4 36337266 [A/G] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs16992103 4 36337470 [A/G] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs9654132 4 36340753 [A/G] NM_001136536,NM_001170700 DTHD1,DTHD1 EXON Missense_R497H,Missense_R662H rs11936656 4 36341751 [T/C] NM_001136536,NM_001170700 DTHD1,DTHD1 Silent,Silent rs2270880 4 36345377 [A/G] NM_001136536,NM_001170700 DTHD1,DTHD1 EXON Synonymous_E594E,Synonymous_E759E rs16992136 4 36350375 [A/G] rs13101999 4 36350425 [T/C] rs7699358 4 36350641 [A/C] rs1392891 4 36354203 [T/C] rs7671923 4 36356690 [A/G] rs4833131 4 36359605 [T/C] rs9990579 4 36360969 [T/C] rs4833132 4 36363694 [T/C] rs6810602 4 36365443 [T/G] rs16992173 4 36365837 [T/C] rs16992175 4 36366711 [T/C] rs6857376 4 36369934 [T/C] rs2375870 4 36375367 [T/C] rs1501114 4 36387599 [A/G] rs6856664 4 36390881 [A/G] rs16992270 4 36392769 [A/G] rs10003626 4 36396090 [T/G] rs949807 4 36398436 [A/G] rs1501116 4 36403061 [T/C] rs12504578 4 36403633 [A/G] rs924536 4 36405777 [T/C] rs12509105 4 36408109 [A/C] rs4833134 4 36409924 [A/G] rs4527502 4 36411073 [A/C] rs4629469 4 36419047 [A/G] rs3925092 4 36419298 [A/G] rs6855055 4 36429725 [A/G] rs7696909 4 36435081 [T/C] rs9884802 4 36447541 [T/C] rs4605678 4 36449901 [T/C] rs3949 4 36451424 [T/C] rs4355409 4 36454804 [A/G] rs4131542 4 36460981 [A/C] rs10001470 4 36461320 [A/G] rs7662602 4 36464948 [A/G] rs10016490 4 36467624 [T/G] rs13112410 4 36468162 [T/C] rs3922552 4 36470307 [A/G] rs7670898 4 36483601 [A/G] rs13133201 4 36484686 [A/G] rs7666077 4 36512868 [T/C] NR_149124 LINC02505 Silent rs13128058 4 36517634 [T/C] NR_149124 LINC02505 Silent rs2375953 4 36520451 [T/C] NR_149124 LINC02505 Silent rs2375971 4 36527853 [T/C] NR_149124 LINC02505 Silent rs6829630 4 36531423 [A/G] NR_149124 LINC02505 Silent rs6531458 4 36534404 [T/C] NR_149124 LINC02505 Silent rs11730794 4 36540033 [T/C] NR_149124 LINC02505 Silent rs12507648 4 36546041 [A/C] NR_149124 LINC02505 Silent rs7675488 4 36547345 [T/C] NR_149124 LINC02505 Silent rs35570301 4 36555185 [T/C] NR_149124 LINC02505 Silent rs7694026 4 36562966 [A/G] NR_149124 LINC02505 Silent rs11936311 4 36572626 [T/C] NR_149124 LINC02505 Silent rs10010198 4 36573898 [T/C] NR_149124 LINC02505 Silent rs10010760 4 36583469 [T/C] NR_149124 LINC02505 Silent rs7675733 4 36597275 [T/C] NR_149124 LINC02505 Silent rs6814457 4 36603313 [A/C] NR_149124 LINC02505 Silent rs11737439 4 36616598 [T/C] NR_149124 LINC02505 Silent rs4576003 4 36620780 [A/G] NR_149124 LINC02505 Silent rs6820713 4 36628000 [T/C] NR_149124 LINC02505 Silent rs10015119 4 36631155 [A/G] NR_149124 LINC02505 Silent rs6820169 4 36637447 [A/G] NR_149124 LINC02505 Silent rs2375997 4 36643076 [A/G] NR_149124 LINC02505 Silent rs6819096 4 36650104 [A/G] rs16992544 4 36650196 [T/C] rs17525084 4 36653468 [T/C] rs17465676 4 36656080 [T/G] rs4146579 4 36656412 [A/G] rs2259467 4 36665729 [A/G] rs2053660 4 36666684 [A/C] rs4610347 4 36671810 [T/C] rs4833153 4 36679326 [T/C] rs2376150 4 36684936 [A/G] rs6842982 4 36692005 [A/G] rs10517382 4 36699959 [A/G] rs6843202 4 36721478 [T/C] rs16992596 4 36724296 [T/C] rs6835248 4 36733188 [T/C] rs12511017 4 36742625 [A/G] rs12650943 4 36756697 [T/C] rs970787 4 36766128 [T/C] rs6849430 4 36787860 [A/G] rs9683431 4 36788024 [T/G] rs1114364 4 36792676 [A/G] rs13118018 4 36792841 [A/G] rs4832818 4 36811363 [T/C] rs1380425 4 36814622 [T/C] rs13152060 4 36832942 [A/G] rs12648032 4 36835439 [T/G] rs1370459 4 36837111 [A/G] rs6531484 4 36844337 [T/C] rs1870504 4 36847609 [A/G] rs6856563 4 36848556 [T/C] rs10030893 4 36850850 [T/C] rs16992742 4 36851751 [A/G] rs1156274 4 36853355 [A/G] rs4527484 4 36863788 [A/G] rs6828250 4 36863831 [A/C] rs6831123 4 36867966 [T/C] rs1459680 4 36869719 [T/C] rs4832838 4 36874981 [A/C] rs7660024 4 36880769 [T/C] rs16992843 4 36886114 [T/C] rs6817693 4 36890895 [T/G] rs11934797 4 36894737 [T/C] rs6838632 4 36907301 [T/C] rs11096840 4 36915898 [T/C] rs6531493 4 36916955 [T/G] rs1531327 4 36919306 [A/G] rs1444330 4 36920723 [A/G] rs12506032 4 36924014 [T/C] rs1026531 4 36926442 [T/C] rs12511779 4 36930054 [A/C] rs1373474 4 36931370 [T/C] rs1373475 4 36931424 [A/G] rs10019844 4 36931883 [A/C] rs11722571 4 36946521 [A/C] rs12505300 4 36948102 [T/C] rs4832844 4 36948351 [A/G] rs1020808 4 36949073 [A/G] rs16992950 4 36957116 [T/C] rs1584108 4 36960436 [A/G] rs1545689 4 36968604 [A/C] rs1444310 4 36979771 [A/G] rs13145944 4 36980142 [A/G] rs6857317 4 36980534 [A/G] rs2166094 4 36982008 [A/G] rs9306942 4 36983307 [A/C] rs2044294 4 36991491 [T/C] rs11096855 4 36994638 [A/C] rs2588548 4 36998478 [T/C] rs1998470 4 37005578 [T/C] NR_134669 LOC100508631 Silent rs13111292 4 37020558 [A/G] NR_134669 LOC100508631 EXON Silent rs1885881 4 37034349 [T/C] rs17289939 4 37036317 [A/C] rs9999604 4 37040171 [A/G] rs17420490 4 37041426 [A/C] rs11724117 4 37044482 [A/G] rs2376322 4 37044712 [T/C] rs6822547 4 37044986 [T/G] rs11725553 4 37046166 [A/G] rs1957748 4 37054888 [T/C] rs11726724 4 37061532 [T/C] rs4832859 4 37062345 [A/G] rs6817779 4 37063069 [A/G] rs6825814 4 37067592 [T/C] rs4832868 4 37069574 [A/G] rs1469312 4 37070668 [T/C] rs13144248 4 37070916 [A/G] rs1951774 4 37072029 [A/C] rs11943045 4 37072746 [T/C] rs10024369 4 37074023 [A/G] rs10484209 4 37074040 [T/C] rs10484210 4 37075996 [A/G] rs11933169 4 37076572 [A/G] rs1426414 4 37085237 [A/C] rs9684775 4 37089445 [A/G] rs4289452 4 37091905 [T/G] rs919103 4 37094678 [T/C] rs17826890 4 37097381 [A/C] rs11733992 4 37098598 [A/G] rs1365342 4 37099533 [A/G] rs12507016 4 37099612 [A/C] rs6829105 4 37103580 [A/G] rs2376183 4 37109848 [A/G] rs12500588 4 37111552 [A/G] rs1972697 4 37126314 [T/G] rs10031432 4 37133279 [A/G] rs34855198 4 37134174 [T/C] rs4832877 4 37139301 [A/C] rs4832726 4 37140039 [T/C] rs12502592 4 37140633 [T/C] rs725292 4 37143147 [T/C] rs10484216 4 37156548 [T/C] rs2376241 4 37163951 [T/G] rs17548458 4 37165240 [A/G] rs1776529 4 37167548 [A/G] rs16993295 4 37173081 [A/G] rs12510063 4 37173484 [T/C] rs1648404 4 37175523 [T/C] rs17529 4 37175719 [T/C] rs7678296 4 37182646 [T/C] rs1627800 4 37184279 [A/C] rs1648395 4 37187191 [A/G] rs1342993 4 37187913 [T/C] rs1648392 4 37197362 [A/G] rs1426401 4 37198777 [T/C] rs1418876 4 37207259 [A/G] rs1418879 4 37208370 [T/C] rs11937850 4 37210649 [A/G] rs1435386 4 37218366 [A/C] rs16993352 4 37232282 [T/C] rs1776575 4 37235854 [A/G] rs1435383 4 37238325 [T/G] rs2211439 4 37240192 [T/C] rs1023730 4 37240580 [T/G] rs1656197 4 37244135 [A/C] rs1469807 4 37250289 [T/C] NM_001144990 NWD2 Silent rs7669853 4 37251630 [T/C] NM_001144990 NWD2 Silent rs17603438 4 37253250 [A/G] NM_001144990 NWD2 Silent rs989655 4 37254333 [T/G] NM_001144990 NWD2 Silent rs1618748 4 37254584 [A/G] NM_001144990 NWD2 Silent rs11932737 4 37254768 [T/C] NM_001144990 NWD2 Silent rs7661725 4 37255211 [T/C] NM_001144990 NWD2 Silent rs7674779 4 37257069 [A/C] NM_001144990 NWD2 Silent rs10015594 4 37258086 [A/G] NM_001144990 NWD2 Silent rs6531521 4 37258713 [T/C] NM_001144990 NWD2 Silent rs10517405 4 37259703 [T/C] NM_001144990 NWD2 Silent rs6855364 4 37262286 [A/G] NM_001144990 NWD2 Silent rs4832890 4 37264627 [A/G] NM_001144990 NWD2 Silent rs3910363 4 37264831 [A/G] NM_001144990 NWD2 Silent rs13129949 4 37268477 [T/C] NM_001144990 NWD2 Silent rs1435378 4 37269105 [T/C] NM_001144990 NWD2 Silent rs1594983 4 37272433 [A/G] NM_001144990 NWD2 Silent rs1776560 4 37285195 [A/G] NM_001144990 NWD2 Silent rs1656182 4 37291336 [A/G] NM_001144990 NWD2 Silent rs2040051 4 37292536 [A/C] NM_001144990 NWD2 Silent rs1656235 4 37293830 [A/C] NM_001144990 NWD2 Silent rs1625910 4 37295894 [T/G] NM_001144990 NWD2 Silent rs7664806 4 37297719 [A/C] NM_001144990 NWD2 Silent rs1627193 4 37310608 [T/C] NM_001144990 NWD2 Silent rs1656216 4 37319167 [A/G] NM_001144990 NWD2 Silent rs1435389 4 37319418 [A/G] NM_001144990 NWD2 Silent rs4337743 4 37322825 [A/G] NM_001144990 NWD2 Silent rs17603641 4 37328396 [A/G] NM_001144990 NWD2 Silent rs17575890 4 37329512 [T/C] NM_001144990 NWD2 Silent rs936595 4 37330939 [A/G] NM_001144990 NWD2 Silent rs7679428 4 37331417 [A/G] NM_001144990 NWD2 Silent rs7434368 4 37335338 [A/G] NM_001144990 NWD2 Silent rs12649785 4 37335699 [A/C] NM_001144990 NWD2 Silent rs12650456 4 37335756 [T/C] NM_001144990 NWD2 Silent rs17603726 4 37336553 [T/G] NM_001144990 NWD2 Silent rs17575939 4 37336803 [T/G] NM_001144990 NWD2 Silent rs10001618 4 37340671 [T/C] NM_001144990 NWD2 Silent rs13340226 4 37342620 [A/G] NM_001144990 NWD2 Silent rs11096868 4 37348193 [T/C] NM_001144990 NWD2 Silent rs13120150 4 37349537 [A/G] NM_001144990 NWD2 Silent rs1002363 4 37357559 [A/G] NM_001144990 NWD2 Silent rs3892368 4 37360983 [A/G] NM_001144990 NWD2 Silent rs6850878 4 37368174 [T/C] NM_001144990 NWD2 Silent rs10517410 4 37369204 [A/G] NM_001144990 NWD2 Silent rs4264838 4 37369765 [A/G] NM_001144990 NWD2 Silent rs6823583 4 37374046 [A/G] NM_001144990 NWD2 Silent rs764882 4 37382184 [T/C] NM_001144990 NWD2 Silent rs16993503 4 37384644 [T/G] NM_001144990 NWD2 Silent rs17493545 4 37385010 [A/G] NM_001144990 NWD2 Silent rs7375557 4 37385086 [A/C] NM_001144990 NWD2 Silent rs17603961 4 37386498 [T/G] NM_001144990 NWD2 Silent rs13131217 4 37386993 [T/C] NM_001144990 NWD2 Silent rs6832220 4 37390472 [A/G] NM_001144990 NWD2 Silent rs6837863 4 37390658 [T/C] NM_001144990 NWD2 Silent rs10013737 4 37391031 [A/G] NM_001144990 NWD2 Silent rs10013774 4 37393292 [A/G] NM_001144990 NWD2 Silent rs17421729 4 37395148 [A/G] NM_001144990 NWD2 Silent rs6531533 4 37395513 [A/G] NM_001144990 NWD2 Silent rs10028027 4 37400306 [T/C] NM_001144990 NWD2 Silent rs12646961 4 37402609 [A/G] NM_001144990 NWD2 Silent rs1105930 4 37403481 [A/G] NM_001144990 NWD2 Silent rs17493678 4 37404064 [T/G] NM_001144990 NWD2 Silent rs9306948 4 37404319 [A/G] NM_001144990 NWD2 Silent rs10016142 4 37406051 [T/C] NM_001144990 NWD2 Silent rs4586959 4 37417390 [A/G] NM_001144990 NWD2 Silent rs6816980 4 37417596 [T/C] NM_001144990 NWD2 Silent rs10856831 4 37427661 [A/G] NM_001144990 NWD2 Silent rs2973217 4 37432416 [A/C] NM_001144990 NWD2 Silent rs4634233 4 37445315 [A/C] NM_001144990 NWD2 EXON Missense_L569M rs11724784 4 37445885 [T/C] NM_001144990 NWD2 EXON Synonymous_L759L rs17422084 4 37448299 [T/C] NM_001144990 NWD2 EXON Synonymous_A1563A rs936587 4 37449053 [A/G] NM_001144990 NWD2 EXON Silent rs936588 4 37449086 [A/G] NM_001144990 NWD2 EXON Silent rs10020323 4 37449803 [A/G] NM_001144990 NWD2 EXON Silent rs2928297 4 37457601 [A/G] NM_001104629 C4orf19 Silent rs2928304 4 37466250 [T/C] NM_001104629 C4orf19 Silent rs2973235 4 37469074 [A/G] NM_001104629 C4orf19 Silent rs2928307 4 37469174 [A/G] NM_001104629 C4orf19 Silent rs11096877 4 37470428 [T/C] NM_001104629 C4orf19 Silent rs10517414 4 37471031 [A/C] NM_001104629 C4orf19 Silent rs2376756 4 37471169 [A/G] NM_001104629 C4orf19 Silent rs11941570 4 37473384 [A/G] NM_001104629 C4orf19 Silent rs1382984 4 37476233 [T/C] NM_001104629 C4orf19 Silent rs1382979 4 37480687 [T/G] NM_001104629 C4orf19 Silent rs2928311 4 37481131 [T/C] NM_001104629 C4orf19 Silent rs952903 4 37486417 [A/G] NM_001104629 C4orf19 Silent rs1552021 4 37491386 [T/C] NM_001104629 C4orf19 Silent rs6831631 4 37492758 [T/C] NM_001104629 C4orf19 Silent rs2973255 4 37503658 [T/C] NM_001104629 C4orf19 Silent rs2928330 4 37516608 [A/G] NM_001104629 C4orf19 Silent rs1463575 4 37517112 [T/C] NM_001104629 C4orf19 Silent rs17576970 4 37518464 [A/G] NM_001104629 C4orf19 Silent rs4832912 4 37519030 [T/C] NM_001104629 C4orf19 Silent rs6819803 4 37523672 [T/C] NM_001104629 C4orf19 Silent rs2380725 4 37524887 [T/C] NM_001104629 C4orf19 Silent rs2380727 4 37524958 [T/C] NM_001104629 C4orf19 Silent rs2973296 4 37526213 [A/G] NM_001104629 C4orf19 Silent rs2939712 4 37526293 [T/C] NM_001104629 C4orf19 Silent rs2380734 4 37527529 [A/G] NM_001104629 C4orf19 Silent rs2380737 4 37536119 [A/G] NM_001104629 C4orf19 Silent rs2973285 4 37537307 [T/C] NM_001104629 C4orf19 Silent rs2939748 4 37537569 [A/G] NM_001104629 C4orf19 Silent rs13121029 4 37538137 [T/C] NM_001104629 C4orf19 Silent rs2973284 4 37539777 [A/C] NM_001104629 C4orf19 Silent rs10517412 4 37542625 [A/C] NM_001104629 C4orf19 Silent rs17604934 4 37542764 [T/C] NM_001104629 C4orf19 Silent rs2939745 4 37543344 [T/G] NM_001104629 C4orf19 Silent rs2939743 4 37543562 [A/G] NM_001104629 C4orf19 Silent rs2939739 4 37548617 [A/G] NM_001104629 C4orf19 Silent rs7655445 4 37555201 [T/C] NM_001104629 C4orf19 Silent rs7679643 4 37555279 [A/G] NM_001104629 C4orf19 Silent rs17577242 4 37558665 [A/G] NM_001104629 C4orf19 Silent rs2939720 4 37559226 [T/C] NM_001104629 C4orf19 Silent rs11942503 4 37561254 [A/G] NM_001104629 C4orf19 Silent rs17605100 4 37561641 [A/G] NM_001104629 C4orf19 Silent rs1876804 4 37562007 [T/C] NM_001104629 C4orf19 Silent rs2941002 4 37562604 [T/C] NM_001104629 C4orf19 Silent rs11723493 4 37565263 [T/C] NM_001104629 C4orf19 Silent rs13148220 4 37569593 [A/G] NM_001104629 C4orf19 Silent rs9685958 4 37569966 [A/G] NM_001104629 C4orf19 Silent rs2939724 4 37572257 [A/G] NM_001104629 C4orf19 Silent rs10025159 4 37575251 [T/C] NM_001104629 C4orf19 Silent rs2380763 4 37577791 [A/G] NM_001104629 C4orf19 Silent rs2973236 4 37584100 [T/C] NM_001104629 C4orf19 Silent rs6857179 4 37584399 [A/G] NM_001104629 C4orf19 Silent rs2276944 4 37585670 [A/C] NM_001104629 C4orf19 Silent rs937940 4 37587944 [A/G] NM_001104629,NM_018302 C4orf19,C4orf19 Silent,Silent rs2279994 4 37590570 [A/G] NM_001104629,NM_018302 C4orf19,C4orf19 Silent,Silent rs2973275 4 37592128 [A/G] NM_001104629,NM_018302 C4orf19,C4orf19 EXON Missense_A151T,Missense_A151T rs3733500 4 37592498 [A/G] NM_001104629,NM_018302,NM_001085399 C4orf19,C4orf19,RELL1 EXON Missense_E274G,Missense_E274G,Silent rs13333 4 37593173 [A/G] NM_001104629,NM_018302,NM_001085399 C4orf19,C4orf19,RELL1 EXON Silent,Silent,Silent rs705099 4 37594946 [A/G] NM_001104629,NM_018302,NM_001085399 C4orf19,C4orf19,RELL1 EXON Silent,Silent,Silent rs2939744 4 37595898 [A/G] NM_001085399 RELL1 Silent rs953538 4 37596650 [T/C] NM_001085399 RELL1 Silent rs2973276 4 37597591 [T/C] NM_001085399 RELL1 Silent rs2973278 4 37600835 [T/C] NM_001085399 RELL1 Silent rs2973280 4 37604570 [T/C] NM_001085399 RELL1 Silent rs10050295 4 37604982 [A/G] NM_001085399 RELL1 Silent rs2939736 4 37606858 [T/C] NM_001085399 RELL1 Silent rs2102336 4 37608199 [A/G] NM_001085399 RELL1 Silent rs12640317 4 37609699 [A/G] NM_001085399 RELL1 Silent rs2939732 4 37610768 [T/C] NM_001085399 RELL1 Silent rs12142 4 37612526 [A/G] NM_001085399,NM_001085400 RELL1,RELL1 EXON Silent,Silent rs17495047 4 37613930 [A/G] NM_001085399,NM_001085400 RELL1,RELL1 EXON Silent,Silent rs17423188 4 37615611 [A/G] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs16993717 4 37617389 [A/G] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs2048257 4 37618938 [A/G] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs2174657 4 37631874 [A/C] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs17577515 4 37633759 [T/C] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs4482771 4 37634192 [T/C] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs2276943 4 37636750 [T/G] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs17577550 4 37637576 [A/G] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs11733542 4 37639139 [T/C] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs6838115 4 37640080 [A/G] NM_001085399,NM_001085400 RELL1,RELL1 EXON Synonymous_Y144Y,Synonymous_Y144Y rs3756143 4 37640389 [T/C] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs6818798 4 37640483 [A/C] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs12499505 4 37644641 [T/C] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs17577641 4 37646759 [A/G] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs17495288 4 37647093 [A/G] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs7690781 4 37653622 [A/G] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs9998333 4 37653656 [A/G] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs17577718 4 37654480 [T/G] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs16993773 4 37665044 [A/C] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs6531568 4 37668484 [A/G] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs919006 4 37675941 [A/C] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs1465497 4 37680384 [T/C] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs4407515 4 37684896 [A/G] NM_001085399,NM_001085400 RELL1,RELL1 Silent,Silent rs1472951 4 37689747 [A/G] rs10222926 4 37690582 [A/G] rs6817818 4 37694948 [A/C] rs10011758 4 37695637 [T/C] rs6831628 4 37697032 [A/G] rs2009494 4 37698453 [A/G] rs1364830 4 37699165 [A/G] rs17423781 4 37701453 [A/G] rs7660340 4 37704067 [A/G] rs17423816 4 37704835 [T/C] rs13115041 4 37707375 [T/C] rs13115042 4 37708086 [T/G] rs13137307 4 37711228 [A/G] rs6531575 4 37712187 [A/G] rs10028206 4 37716343 [T/C] rs10017065 4 37719424 [A/G] rs12505604 4 37720580 [T/C] rs12505935 4 37723990 [A/G] rs7666650 4 37725293 [T/C] rs961082 4 37727622 [A/G] rs11936663 4 37728866 [T/C] rs1469236 4 37741826 [A/C] rs17424009 4 37750227 [A/G] rs2995977 4 37752668 [T/C] rs2995976 4 37754104 [T/C] rs1465496 4 37756236 [A/G] rs17605986 4 37758324 [A/G] rs11726893 4 37758827 [T/G] rs10517429 4 37759253 [A/G] rs17496030 4 37760049 [T/C] rs2995972 4 37764357 [T/C] rs4240241 4 37766932 [A/G] rs929959 4 37768842 [T/C] rs929958 4 37769060 [A/C] rs933817 4 37769325 [T/C] rs919005 4 37769527 [A/G] rs1125117 4 37770401 [T/C] rs1025146 4 37771002 [A/G] rs7698331 4 37772443 [T/C] rs4832940 4 37773485 [A/C] rs2911862 4 37773849 [T/C] rs2995965 4 37780765 [A/G] rs4463081 4 37785000 [A/G] rs870953 4 37786987 [A/G] rs7692977 4 37787117 [T/C] rs10030419 4 37787351 [T/C] rs955868 4 37790259 [A/G] rs12640538 4 37795022 [T/C] rs10000119 4 37796830 [T/C] rs955290 4 37797027 [A/G] rs1863284 4 37797841 [T/C] rs2995958 4 37799735 [A/G] rs1109971 4 37803352 [T/C] rs2911874 4 37803799 [A/G] rs2911869 4 37805051 [A/G] rs11096906 4 37807815 [T/C] rs7437855 4 37808510 [T/C] rs4832737 4 37812202 [A/G] rs12648108 4 37826862 [A/G] rs2911908 4 37830383 [A/G] NM_018290 PGM2 Silent rs2714555 4 37837819 [A/G] NM_018290 PGM2 Silent rs2608307 4 37838237 [T/C] NM_018290 PGM2 Silent rs3775793 4 37840606 [A/G] NM_018290 PGM2 Silent rs2714559 4 37841942 [T/C] NM_018290 PGM2 Silent rs2714560 4 37843161 [A/G] NM_018290 PGM2 Silent rs2290741 4 37849004 [T/C] NM_018290 PGM2 Silent rs10001580 4 37851856 [A/C] NM_018290 PGM2 EXON Missense_E488D rs4832960 4 37854182 [A/G] NM_018290 PGM2 Silent rs6842360 4 37857166 [A/G] NM_018290 PGM2 Silent rs6812086 4 37858815 [T/G] NM_018290 PGM2 Silent rs6531591 4 37858954 [T/C] NM_018290 PGM2 Silent rs6844466 4 37860967 [T/C] NM_018290 PGM2 Silent rs4832962 4 37862071 [A/G] NM_018290 PGM2 Silent rs6820778 4 37862522 [T/C] NM_018290 PGM2 Silent rs10569 4 37863385 [T/C] NM_018290 PGM2 EXON Silent rs11734812 4 37868667 [T/C] rs11722588 4 37868805 [A/G] rs28571127 4 37870300 [A/G] rs6531592 4 37882167 [T/G] rs7685175 4 37883839 [A/G] rs9996566 4 37884116 [A/C] rs7674949 4 37884481 [T/C] rs17578829 4 37885195 [A/G] rs2995926 4 37898650 [A/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs3893296 4 37900371 [A/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs17578878 4 37900725 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs3860063 4 37901088 [A/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs3860064 4 37901153 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs2279029 4 37903382 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs2279027 4 37903756 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 EXON Missense_S14P,Missense_S14P rs2279026 4 37904082 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 EXON Synonymous_A122A,Synonymous_A122A rs35859249 4 37904089 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 EXON Missense_R125W,Missense_R125W rs6531596 4 37905601 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs2995919 4 37906032 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs2925947 4 37909495 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs2925948 4 37909841 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs2995916 4 37910996 [T/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs2995915 4 37911508 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs2925952 4 37911638 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs11096913 4 37915462 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs2925956 4 37920053 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs16994074 4 37925978 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs11096914 4 37926784 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs17497040 4 37926978 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs4240242 4 37929534 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs4832745 4 37930312 [T/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs11942956 4 37933081 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs17579011 4 37936849 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs10010758 4 37938518 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs4351030 4 37949311 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs13121101 4 37955351 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs2290740 4 37962133 [A/G] NM_001253912,NM_015173,NM_006607 TBC1D1,TBC1D1,PTTG2 EXON Silent,Silent,Synonymous_L26L rs13109321 4 37965492 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs11736130 4 37965827 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs10517460 4 37967083 [A/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs9306955 4 37970850 [A/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs2381131 4 37971275 [T/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs6858227 4 37973722 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs2890591 4 37975020 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs3849020 4 37975204 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs6850410 4 37979512 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs10011664 4 37989306 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs6841167 4 37990581 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs11943860 4 37991472 [T/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs6858606 4 37995170 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs1344602 4 37996334 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs10084926 4 37996827 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs16994133 4 37999876 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs7672883 4 38006686 [A/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs17579337 4 38007559 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs6835205 4 38007612 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs10517464 4 38009782 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs4832980 4 38010293 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs16994140 4 38011565 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs16994148 4 38016822 [T/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs13142228 4 38018181 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs11946822 4 38018480 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs7671645 4 38019302 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs1364951 4 38019436 [T/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs933819 4 38026106 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs933821 4 38026389 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs7670756 4 38032931 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs10018389 4 38046569 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs11096921 4 38046709 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs17425670 4 38058764 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs1863329 4 38060485 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs16994165 4 38062263 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs17497671 4 38073974 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs10001462 4 38074186 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs933818 4 38079294 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs10009706 4 38079475 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs1425576 4 38080507 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs1863326 4 38086795 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs1863325 4 38087105 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs2303421 4 38092096 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs10517469 4 38097478 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs2114014 4 38103016 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs933823 4 38103550 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs933822 4 38105161 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs3890061 4 38106236 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs1344603 4 38109847 [T/C] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs754886 4 38110620 [A/G] NM_001253912,NM_015173 TBC1D1,TBC1D1 Silent,Silent rs645469 4 38122459 [A/G] NM_001253912,NM_015173,NM_001253913,NM_001253914,NM_001253915 TBC1D1,TBC1D1,TBC1D1,TBC1D1,TBC1D1 Silent,Silent,Silent,Silent,Silent rs2067557 4 38123916 [T/C] NM_001253912,NM_015173,NM_001253913,NM_001253914,NM_001253915 TBC1D1,TBC1D1,TBC1D1,TBC1D1,TBC1D1 Silent,Silent,Silent,Silent,Silent rs637495 4 38129949 [T/C] NM_001253912,NM_015173,NM_001253913,NM_001253914,NM_001253915 TBC1D1,TBC1D1,TBC1D1,TBC1D1,TBC1D1 Silent,Silent,Silent,Silent,Silent rs13119350 4 38131076 [A/G] NM_001253912,NM_015173,NM_001253913,NM_001253914,NM_001253915 TBC1D1,TBC1D1,TBC1D1,TBC1D1,TBC1D1 Silent,Silent,Silent,Silent,Silent rs605073 4 38131255 [A/G] NM_001253912,NM_015173,NM_001253913,NM_001253914,NM_001253915 TBC1D1,TBC1D1,TBC1D1,TBC1D1,TBC1D1 Silent,Silent,Silent,Silent,Silent rs633059 4 38132999 [A/G] NM_001253912,NM_015173,NM_001253913,NM_001253914,NM_001253915 TBC1D1,TBC1D1,TBC1D1,TBC1D1,TBC1D1 Silent,Silent,Silent,Silent,Silent rs6816462 4 38137850 [T/C] NM_001253912,NM_015173,NM_001253913,NM_001253914,NM_001253915 TBC1D1,TBC1D1,TBC1D1,TBC1D1,TBC1D1 Silent,Silent,Silent,Silent,Silent rs13110318 4 38138856 [A/G] NM_001253912,NM_015173,NM_001253913,NM_001253914,NM_001253915 TBC1D1,TBC1D1,TBC1D1,TBC1D1,TBC1D1 EXON Missense_R1127Q,Missense_R1136Q,Missense_R233Q,Missense_R233Q,Missense_R148Q rs9852 4 38139024 [T/C] NM_001253912,NM_015173,NM_001253913,NM_001253914,NM_001253915 TBC1D1,TBC1D1,TBC1D1,TBC1D1,TBC1D1 EXON Silent,Silent,Silent,Silent,Silent rs16994266 4 38140363 [T/G] NM_001253912,NM_015173,NM_001253913,NM_001253914,NM_001253915 TBC1D1,TBC1D1,TBC1D1,TBC1D1,TBC1D1 EXON Silent,Silent,Silent,Silent,Silent rs10021783 4 38145373 [A/G] rs12641222 4 38154707 [T/C] rs12645765 4 38155431 [T/C] rs6814900 4 38157510 [T/G] rs17607861 4 38158024 [T/G] rs12510952 4 38158043 [A/G] rs12503618 4 38158347 [T/C] rs6844679 4 38162567 [T/C] rs10028650 4 38166020 [T/C] rs6849562 4 38167985 [T/C] rs4832749 4 38169660 [A/G] rs907311 4 38170057 [T/C] rs1991231 4 38170173 [A/G] rs4832992 4 38172840 [A/G] rs2380964 4 38175276 [A/G] rs6856418 4 38176864 [T/C] rs617615 4 38179244 [T/C] rs7436530 4 38179948 [A/G] rs11932593 4 38179990 [T/C] rs693978 4 38180161 [A/G] rs659831 4 38180288 [A/G] rs6854035 4 38181054 [T/C] rs586844 4 38187084 [T/C] rs17577389 4 38188921 [A/C] rs4832994 4 38189873 [T/C] rs11737462 4 38190035 [A/G] rs17498347 4 38194576 [T/C] rs17580275 4 38195371 [T/C] rs2380962 4 38197189 [T/G] rs4833009 4 38202601 [T/C] rs6531613 4 38203158 [T/C] rs4832752 4 38204133 [A/G] rs1397816 4 38205831 [T/C] rs4389587 4 38211434 [A/C] rs4554086 4 38212624 [T/C] rs11096935 4 38213113 [A/G] rs11096936 4 38213124 [A/G] rs10012308 4 38213331 [A/G] rs6833738 4 38216411 [A/G] rs7654067 4 38225077 [T/C] rs2381135 4 38225756 [T/C] rs6531617 4 38228570 [A/G] rs2055889 4 38231635 [T/G] rs10022626 4 38233376 [T/C] rs12648491 4 38233985 [T/C] rs6857949 4 38237981 [A/G] rs4833014 4 38238718 [T/C] rs7695667 4 38241220 [T/C] rs13139983 4 38243991 [T/C] rs16994359 4 38246265 [T/C] rs4833022 4 38251292 [A/C] rs17426830 4 38253255 [T/C] rs4279220 4 38254182 [T/C] rs907314 4 38254453 [T/C] rs4833025 4 38257243 [T/C] rs1467093 4 38262829 [T/C] rs973787 4 38263893 [T/C] rs1467092 4 38270176 [A/G] rs1467091 4 38270461 [T/G] rs16994377 4 38270567 [T/C] rs1006658 4 38271832 [T/C] rs7660869 4 38276064 [T/C] rs11725412 4 38277754 [A/G] rs1995963 4 38277904 [T/C] rs6838003 4 38279039 [T/C] rs4833028 4 38280267 [A/G] rs17580746 4 38280712 [A/G] rs4833029 4 38283255 [T/C] rs13119207 4 38285407 [T/C] rs9684138 4 38287192 [T/C] rs10517472 4 38287333 [T/C] rs4995512 4 38288687 [T/G] rs1553879 4 38291344 [T/G] rs6847801 4 38298269 [T/C] rs2890608 4 38301690 [A/G] rs13146334 4 38302418 [T/C] rs7676429 4 38304013 [T/C] rs11723878 4 38305636 [T/C] rs991331 4 38308761 [T/G] rs1586459 4 38314170 [A/G] rs4833034 4 38318354 [T/C] rs1466614 4 38318791 [A/C] rs7677938 4 38321682 [T/C] rs6812414 4 38322807 [A/C] rs6856616 4 38325036 [T/C] rs1906297 4 38325105 [T/C] rs13139166 4 38330855 [T/C] rs13101978 4 38333458 [T/A] rs17614875 4 38334899 [T/C] rs12502507 4 38343533 [A/G] rs12502727 4 38344189 [A/G] rs716975 4 38349236 [T/C] rs2381149 4 38362065 [A/C] rs13133642 4 38366090 [T/C] rs1487624 4 38367538 [A/G] rs6810650 4 38370063 [T/C] NR_149123 LINC02513 Silent rs2046643 4 38372849 [A/G] NR_149123 LINC02513 Silent rs1906292 4 38372995 [T/C] NR_149123 LINC02513 Silent rs11732737 4 38374153 [T/C] NR_149123 LINC02513 Silent rs11722631 4 38375537 [A/C] NR_149123 LINC02513 Silent rs17581054 4 38376012 [T/C] NR_149123 LINC02513 Silent rs6821082 4 38376515 [T/C] NR_149123 LINC02513 Silent rs17581075 4 38376863 [T/C] NR_149123 LINC02513 Silent rs12646716 4 38379565 [A/G] NR_149123 LINC02513 Silent rs7667070 4 38379833 [T/C] NR_149123 LINC02513 Silent rs7668402 4 38380708 [A/G] NR_149123 LINC02513 Silent rs2291433 4 38387075 [T/G] NR_149123 LINC02513 EXON Silent rs1487632 4 38391687 [T/C] rs6854078 4 38394714 [T/C] rs6531631 4 38396739 [A/G] rs6832648 4 38398572 [T/G] rs12511283 4 38402111 [T/C] rs6855205 4 38404964 [A/G] rs17581201 4 38409358 [A/G] rs901703 4 38413846 [T/C] rs1487620 4 38419597 [A/G] rs1487618 4 38419843 [A/G] rs10012289 4 38425619 [T/C] NR_110951 LINC01258 Silent rs1601758 4 38433101 [T/C] NR_110951 LINC01258 Silent rs7673568 4 38433730 [T/C] NR_110951 LINC01258 Silent rs6830905 4 38443544 [A/G] NR_110951 LINC01258 Silent rs4240245 4 38452184 [T/C] NR_110951 LINC01258 Silent rs17581460 4 38456404 [T/C] NR_110951 LINC01258 Silent rs1004064 4 38458620 [A/G] NR_110951 LINC01258 Silent rs17615370 4 38464493 [A/G] NR_110951 LINC01258 Silent rs4131726 4 38465656 [A/C] NR_110951 LINC01258 Silent rs4833057 4 38475721 [A/G] NR_110951 LINC01258 Silent rs4832778 4 38492765 [A/G] NR_110951 LINC01258 Silent rs9996673 4 38503527 [A/G] NR_110951 LINC01258 Silent rs11723479 4 38506777 [A/C] NR_110951 LINC01258 Silent rs2637718 4 38508357 [T/C] NR_110951 LINC01258 Silent rs1873515 4 38509827 [T/C] NR_110951 LINC01258 Silent rs10517485 4 38511135 [A/G] NR_110951 LINC01258 Silent rs4833065 4 38512602 [T/C] NR_110951,NR_149076 LINC01258,LINC01259 Silent,Silent rs2220634 4 38513691 [T/G] NR_110951,NR_149076 LINC01258,LINC01259 Silent,Silent rs17500058 4 38514293 [A/G] NR_110951,NR_149076 LINC01258,LINC01259 Silent,Silent rs2609467 4 38515141 [A/G] NR_110951,NR_149076 LINC01258,LINC01259 Silent,Silent rs11946196 4 38519943 [A/G] NR_110951 LINC01258 Silent rs902649 4 38520456 [A/C] NR_110951 LINC01258 Silent rs2637729 4 38523522 [A/G] NR_110951 LINC01258 Silent rs6814050 4 38524098 [A/G] NR_110951 LINC01258 Silent rs7687994 4 38524446 [A/G] NR_110951 LINC01258 Silent rs17615522 4 38527901 [A/C] rs16994596 4 38532882 [A/G] rs7688952 4 38533692 [A/C] rs16994601 4 38537654 [A/G] rs923665 4 38537708 [T/C] rs16994602 4 38537844 [A/G] rs7675136 4 38539272 [A/G] rs7658907 4 38539297 [T/C] rs3860065 4 38540930 [T/G] rs2703904 4 38548187 [A/G] rs1552684 4 38551146 [A/C] rs6853067 4 38562694 [A/G] rs10026499 4 38564339 [A/G] rs2703887 4 38570178 [T/C] NR_146991 LINC02278 Silent rs2703888 4 38570506 [T/C] NR_146991 LINC02278 Silent rs7654396 4 38570708 [A/G] NR_146991 LINC02278 EXON Silent rs16994644 4 38572392 [T/C] NR_146991 LINC02278 EXON Silent rs11726368 4 38578754 [T/C] rs4833071 4 38582859 [T/C] rs6531644 4 38584276 [A/G] rs4401459 4 38585268 [A/C] rs7678850 4 38592867 [T/C] rs12506499 4 38592972 [T/C] rs6811246 4 38593723 [A/G] rs2169541 4 38596365 [T/C] rs16994672 4 38596653 [T/C] rs337635 4 38603272 [A/C] rs337637 4 38604470 [A/G] rs3860066 4 38611565 [A/G] rs337641 4 38611802 [A/G] rs1962053 4 38612357 [A/C] rs337646 4 38616410 [T/C] NR_026804 KLF3-AS1 Silent rs2637713 4 38627337 [A/G] NR_026804 KLF3-AS1 EXON Silent rs1993796 4 38644050 [A/G] NR_026804 KLF3-AS1 Silent rs1824652 4 38644597 [T/C] NR_026804 KLF3-AS1 Silent rs6827414 4 38650464 [T/C] NR_026804 KLF3-AS1 Silent rs4833079 4 38654681 [T/C] NR_026804 KLF3-AS1 Silent rs337609 4 38662059 [A/C] NR_026804 KLF3-AS1 Silent rs1466414 4 38664324 [A/G] NR_026804 KLF3-AS1 Silent rs9522 4 38666972 [T/C] NM_016531 KLF3 Silent rs9992667 4 38680186 [T/C] NM_016531 KLF3 Silent rs16994718 4 38688362 [T/C] NM_016531 KLF3 Silent rs17428931 4 38689042 [A/G] NM_016531 KLF3 Silent rs3796533 4 38692806 [A/G] NM_016531 KLF3 Silent rs1000096 4 38692835 [T/C] NM_016531 KLF3 Silent rs2045767 4 38696934 [T/G] NM_016531 KLF3 Silent rs3209570 4 38699657 [A/G] NM_016531 KLF3 EXON Silent rs7147 4 38702437 [A/G] NM_016531 KLF3 EXON Silent rs17500878 4 38702929 [A/G] NM_016531 KLF3 EXON Silent rs5029114 4 38703005 [A/G] NM_016531 KLF3 EXON Silent rs17582575 4 38703734 [A/C] rs10021686 4 38705257 [T/C] rs7695936 4 38709078 [A/C] rs13132956 4 38711684 [T/C] rs6813851 4 38712167 [A/C] rs6838905 4 38712286 [A/G] rs13149231 4 38716483 [T/C] rs16994732 4 38717953 [A/G] rs1005761 4 38722709 [A/G] rs17616338 4 38723613 [T/C] rs7660102 4 38724573 [A/C] rs7658334 4 38728076 [A/G] rs7660114 4 38732464 [T/C] rs7660350 4 38732611 [T/C] rs2890620 4 38736550 [T/C] rs12233656 4 38737018 [A/G] rs6823756 4 38740794 [T/C] rs6842064 4 38741445 [T/C] rs9968502 4 38741849 [T/C] rs6838865 4 38745883 [T/G] rs11946541 4 38750680 [A/G] rs4540058 4 38751694 [A/G] rs4565081 4 38752985 [A/G] rs6824105 4 38754189 [A/G] rs10008492 4 38765720 [T/C] rs4331786 4 38769408 [T/C] rs10776482 4 38774785 [A/G] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 EXON Synonymous_D809D,Synonymous_D795D,Synonymous_D809D,Synonymous_D809D,Synonymous_D809D rs4129009 4 38774889 [T/C] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 EXON Missense_I775V,Missense_I761V,Missense_I775V,Missense_I775V,Missense_I775V rs10776483 4 38775040 [A/G] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 EXON Synonymous_H724H,Synonymous_H710H,Synonymous_H724H,Synonymous_H724H,Synonymous_H724H rs11466657 4 38775794 [A/G] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 EXON Missense_I473T,Missense_I459T,Missense_I473T,Missense_I473T,Missense_I473T rs11466655 4 38776070 [T/C] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 EXON Missense_G381D,Missense_G367D,Missense_G381D,Missense_G381D,Missense_G381D rs11096956 4 38776180 [A/C] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 EXON Synonymous_P344P,Synonymous_P330P,Synonymous_P344P,Synonymous_P344P,Synonymous_P344P rs11466653 4 38776235 [A/G] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 EXON Missense_M326T,Missense_M312T,Missense_M326T,Missense_M326T,Missense_M326T rs11466652 4 38776303 [T/C] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 EXON Synonymous_K303K,Synonymous_K289K,Synonymous_K303K,Synonymous_K303K,Synonymous_K303K rs11096957 4 38776491 [T/G] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 EXON Missense_N241H,Missense_N227H,Missense_N241H,Missense_N241H,Missense_N241H rs11466650 4 38776712 [A/G] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 EXON Missense_L167P,Missense_L153P,Missense_L167P,Missense_L167P,Missense_L167P rs11466648 4 38776942 [T/C] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 EXON Synonymous_K90K,Synonymous_K76K,Synonymous_K90K,Synonymous_K90K,Synonymous_K90K rs10856837 4 38777059 [T/C] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 EXON Synonymous_T51T,Synonymous_T37T,Synonymous_T51T,Synonymous_T51T,Synonymous_T51T rs10856839 4 38777236 [T/G] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 EXON Silent,Silent,Silent,Silent,Silent rs4274855 4 38777471 [T/C] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 EXON Silent,Silent,Silent,Silent,Silent rs11466642 4 38778255 [T/C] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 Silent,Silent,Silent,Silent,Silent rs11466612 4 38780721 [T/C] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 Silent,Silent,Silent,Silent,Silent rs9998350 4 38783374 [A/C] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 Silent,Silent,Silent,Silent,Silent rs11725309 4 38783848 [T/C] NM_001195107,NM_001195108,NM_001017388,NM_030956,NM_001195106 TLR10,TLR10,TLR10,TLR10,TLR10 Silent,Silent,Silent,Silent,Silent rs7663239 4 38785850 [T/G] rs12233670 4 38787216 [T/C] rs4286521 4 38795306 [A/G] rs3924111 4 38797816 [T/C] rs4624663 4 38797876 [T/C] NM_003263 TLR1 EXON Silent rs5743613 4 38799509 [A/G] NM_003263 TLR1 EXON Missense_P315L rs3923647 4 38799539 [T/A] NM_003263 TLR1 EXON Missense_H305L rs4833095 4 38799710 [T/C] NM_003263 TLR1 EXON Missense_N248S rs5743610 4 38800339 [A/G] NM_003263 TLR1 EXON Synonymous_H38H rs5743596 4 38802528 [A/G] NM_003263 TLR1 EXON Silent rs5743567 4 38805840 [A/G] NM_003263 TLR1 Silent rs5743561 4 38806192 [T/C] NM_003263 TLR1 Silent rs17616434 4 38812876 [T/C] rs4833103 4 38815502 [A/C] rs7696175 4 38820986 [T/C] rs5743824 4 38828470 [A/G] NM_006068 TLR6 EXON Silent rs5743821 4 38828827 [A/C] NM_006068 TLR6 EXON Synonymous_T756T rs5743818 4 38829163 [A/C] NM_006068 TLR6 EXON Synonymous_A644A rs5743815 4 38829815 [A/G] NM_006068 TLR6 EXON Missense_V427A rs3775073 4 38829832 [T/C] NM_006068 TLR6 EXON Synonymous_K421K rs5743813 4 38830062 [A/G] NM_006068 TLR6 EXON Missense_H345Y rs5743810 4 38830350 [A/G] NM_006068 TLR6 EXON Missense_S249P rs5743808 4 38830736 [A/G] NM_006068 TLR6 EXON Missense_I120T rs1039559 4 38831596 [A/G] NM_006068 TLR6 Silent rs6833914 4 38840162 [T/C] NM_006068 TLR6 Silent rs7685852 4 38846885 [A/G] NM_006068 TLR6 Silent rs6531673 4 38847917 [T/C] NM_006068 TLR6 Silent rs17429224 4 38857310 [A/G] NM_006068 TLR6 Silent rs17501134 4 38859515 [T/C] rs1472720 4 38873998 [T/C] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs721653 4 38878194 [T/C] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11096964 4 38879949 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 EXON Missense_G84R,Silent,Silent,Silent,Silent,Silent,Missense_G84R,Missense_G84R rs11944159 4 38880046 [T/C] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 EXON Missense_L116P,Silent,Silent,Silent,Silent,Silent,Missense_L116P,Missense_L116P rs6851463 4 38893736 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6851685 4 38893843 [T/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1604834 4 38897254 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12641669 4 38901769 [A/C] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7676657 4 38910362 [T/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16994921 4 38911315 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7655305 4 38912621 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4240248 4 38916914 [T/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11736617 4 38917830 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12509328 4 38924275 [T/C] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10000037 4 38924330 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9999294 4 38927230 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10155189 4 38927396 [T/C] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389,NM_001350635 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17429570 4 38930433 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3866197 4 38930469 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13150445 4 38931097 [A/C] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4833106 4 38933726 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17429619 4 38933859 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 EXON Missense_V441I,Missense_V316I,Missense_V245I,Missense_V236I,Silent,Missense_V236I,Missense_V443I rs2171778 4 38936833 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12506108 4 38937055 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2271031 4 38937372 [T/C] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 EXON Synonymous_S497S,Synonymous_S372S,Synonymous_S301S,Synonymous_S292S,Silent,Synonymous_S292S,Synonymous_S499S rs6531684 4 38940630 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6812702 4 38940833 [A/G] NM_001350632,NM_001350633,NM_001350634,NM_001350631,NR_033290,NM_001330764,NM_138389 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2011590 4 38944101 [T/C] NM_001350632,NM_001350633,NM_001350634,NR_033290,NM_001330764,NM_138389 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 Silent,Silent,Silent,Silent,Silent,Silent rs6840077 4 38946448 [T/C] NM_001350632,NM_001350633,NM_001350634,NR_033290,NM_001330764,NM_138389 FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1,FAM114A1 EXON Silent,Silent,Silent,Silent,Silent,Silent rs7694333 4 38952030 [A/G] rs2174285 4 38952488 [T/C] rs3806735 4 38953128 [T/C] rs10018196 4 38953494 [A/G] rs17583377 4 38955135 [T/C] rs6833864 4 38958404 [T/C] rs10023125 4 38959165 [T/C] rs17583426 4 38960412 [A/C] rs4974985 4 38961449 [T/G] rs6841592 4 38965986 [A/C] rs2055576 4 38966075 [A/G] rs6820989 4 38966472 [A/G] rs1504238 4 38967146 [T/C] rs4974983 4 38971057 [A/G] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs6814637 4 38978171 [T/C] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs7699651 4 38980064 [T/C] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs6811642 4 38982755 [T/C] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs11946488 4 38984852 [A/G] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs17583467 4 38988587 [A/G] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs17583481 4 38988621 [T/G] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs2276887 4 38990575 [A/G] NM_024943,NM_001303228 TMEM156,TMEM156 EXON Missense_M212T,Missense_M212T rs13106655 4 38992305 [A/G] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs4974979 4 38994187 [T/G] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs11096969 4 39005601 [T/C] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs7662121 4 39008793 [A/G] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs2163276 4 39012630 [T/C] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs2435530 4 39016075 [T/C] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs2566103 4 39019877 [T/C] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs2566104 4 39019912 [T/G] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs3860068 4 39020194 [T/G] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs12642359 4 39027082 [T/C] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs17430272 4 39030678 [A/G] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs6821102 4 39031979 [T/C] NM_024943,NM_001303228 TMEM156,TMEM156 Silent,Silent rs1864495 4 39036311 [A/G] rs2711981 4 39039258 [T/C] rs6813885 4 39045907 [T/C] rs2566120 4 39055870 [T/C] NM_001007075,NM_001171654 KLHL5,KLHL5 Silent,Silent rs2711943 4 39062436 [T/C] NM_001007075,NM_001171654 KLHL5,KLHL5 Silent,Silent rs12500509 4 39063614 [T/G] NM_001007075,NM_001171654 KLHL5,KLHL5 Silent,Silent rs11096974 4 39063659 [T/C] NM_001007075,NM_001171654 KLHL5,KLHL5 Silent,Silent rs2711941 4 39064162 [A/C] NM_001007075,NM_001171654,NM_015990,NM_199039 KLHL5,KLHL5,KLHL5,KLHL5 EXON Silent,Silent,Missense_I10L,Missense_I10L rs2566134 4 39074295 [A/G] NM_001007075,NM_001171654,NM_015990,NM_199039 KLHL5,KLHL5,KLHL5,KLHL5 Silent,Silent,Silent,Silent rs2566142 4 39081681 [A/G] NM_001007075,NM_001171654,NM_015990,NM_199039 KLHL5,KLHL5,KLHL5,KLHL5 Silent,Silent,Silent,Silent rs1036044 4 39084992 [A/C] NM_001007075,NM_001171654,NM_015990,NM_199039 KLHL5,KLHL5,KLHL5,KLHL5 Silent,Silent,Silent,Silent rs3733276 4 39116911 [T/C] NM_001007075,NM_001171654,NM_015990,NM_199039 KLHL5,KLHL5,KLHL5,KLHL5 EXON Synonymous_T678T,Synonymous_T537T,Synonymous_T724T,Synonymous_T663T rs12499266 4 39119753 [T/C] NM_001007075,NM_001171654,NM_015990,NM_199039 KLHL5,KLHL5,KLHL5,KLHL5 Silent,Silent,Silent,Silent rs9997089 4 39120883 [T/C] NM_001007075,NM_001171654,NM_015990,NM_199039 KLHL5,KLHL5,KLHL5,KLHL5 Silent,Silent,Silent,Silent rs9990742 4 39121414 [A/G] NM_001007075,NM_001171654,NM_015990,NM_199039 KLHL5,KLHL5,KLHL5,KLHL5 Silent,Silent,Silent,Silent rs3733275 4 39122697 [T/C] NM_001007075,NM_001171654,NM_015990,NM_199039 KLHL5,KLHL5,KLHL5,KLHL5 EXON Silent,Silent,Silent,Silent rs2566163 4 39129965 [A/G] rs12646251 4 39134371 [A/G] rs10018622 4 39135564 [A/G] rs7654300 4 39137571 [T/C] rs2044917 4 39149491 [A/G] rs2711991 4 39151353 [A/G] rs2711935 4 39162457 [T/C] rs7662153 4 39174790 [T/C] rs1451820 4 39183447 [A/G] rs1451817 4 39205365 [T/C] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs17584431 4 39207318 [A/G] NM_001317924,NM_025132 WDR19,WDR19 EXON Synonymous_S124S,Synonymous_S284S rs2381349 4 39212010 [A/G] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs2167494 4 39216221 [T/C] NM_001317924,NM_025132 WDR19,WDR19 EXON Synonymous_C137C,Synonymous_C297C rs16995187 4 39217289 [T/C] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs16995189 4 39219593 [T/C] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs9997015 4 39224297 [A/G] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs11730558 4 39229771 [A/G] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs11932351 4 39231457 [T/C] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs6845945 4 39231495 [T/C] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs6531698 4 39263814 [T/C] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs4975001 4 39266464 [T/C] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs16995209 4 39267749 [A/G] NM_001317924,NM_025132 WDR19,WDR19 EXON Missense_G924S,Missense_G1084S rs3733280 4 39271541 [A/G] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs2167493 4 39276022 [A/G] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs746678 4 39280655 [A/G] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs2381373 4 39282303 [A/C] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs6531705 4 39284652 [T/G] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs2062229 4 39286766 [T/G] NM_001317924,NM_025132 WDR19,WDR19 Silent,Silent rs1057807 4 39289473 [A/G] NM_001363495,NM_001363496,NM_001204747,NM_002913 RFC1,RFC1,RFC1,RFC1 EXON Silent,Silent,Silent,Silent rs2306597 4 39297200 [A/G] NM_001363495,NM_001363496,NM_001204747,NM_002913 RFC1,RFC1,RFC1,RFC1 Silent,Silent,Silent,Silent rs17335452 4 39297328 [T/G] NM_001363495,NM_001363496,NM_001204747,NM_002913 RFC1,RFC1,RFC1,RFC1 EXON Missense_Q928K,Missense_Q929K,Missense_Q955K,Missense_Q954K rs6531708 4 39301572 [A/G] NM_001363495,NM_001363496,NM_001204747,NM_002913 RFC1,RFC1,RFC1,RFC1 Silent,Silent,Silent,Silent rs2066786 4 39302029 [T/C] NM_001363495,NM_001363496,NM_001204747,NM_002913 RFC1,RFC1,RFC1,RFC1 EXON Synonymous_P821P,Synonymous_P822P,Synonymous_P848P,Synonymous_P847P rs2066790 4 39318706 [A/G] NM_001363495,NM_001363496,NM_001204747,NM_002913 RFC1,RFC1,RFC1,RFC1 Silent,Silent,Silent,Silent rs11096992 4 39329102 [A/G] NM_001363495,NM_001363496,NM_001204747,NM_002913 RFC1,RFC1,RFC1,RFC1 Silent,Silent,Silent,Silent rs4975006 4 39351147 [A/G] NM_001363495,NM_001363496,NM_001204747,NM_002913 RFC1,RFC1,RFC1,RFC1 Silent,Silent,Silent,Silent rs11096995 4 39358058 [T/C] NM_001363495,NM_001363496,NM_001204747,NM_002913 RFC1,RFC1,RFC1,RFC1 Silent,Silent,Silent,Silent rs17584703 4 39364856 [T/C] NM_001363495,NM_001363496,NM_001204747,NM_002913 RFC1,RFC1,RFC1,RFC1 Silent,Silent,Silent,Silent rs6844176 4 39366590 [T/C] NM_001363495,NM_001363496,NM_001204747,NM_002913 RFC1,RFC1,RFC1,RFC1 Silent,Silent,Silent,Silent rs6851075 4 39367654 [T/C] NM_001363495,NM_001363496,NM_001204747,NM_002913 RFC1,RFC1,RFC1,RFC1 Silent,Silent,Silent,Silent rs13123782 4 39377405 [A/C] rs2062228 4 39377646 [T/C] rs6823497 4 39385821 [A/C] rs2381378 4 39395770 [T/G] rs13135439 4 39405151 [T/G] rs13149518 4 39406987 [T/C] rs10003369 4 39408595 [A/C] NM_175737 KLB EXON Missense_S9Y rs11940694 4 39414993 [A/G] NM_175737 KLB Silent rs13147477 4 39419322 [T/C] NM_175737 KLB Silent rs7674434 4 39419409 [T/G] NM_175737 KLB Silent rs3860070 4 39420869 [T/C] NM_175737 KLB Silent rs2608816 4 39426809 [T/C] NM_175737 KLB Silent rs17431867 4 39428295 [T/C] NM_175737 KLB Silent rs1979283 4 39430969 [T/C] NM_175737 KLB Silent rs2608819 4 39431431 [T/C] NM_175737 KLB Silent rs2687963 4 39438149 [A/G] NM_175737 KLB Silent rs4975015 4 39439264 [T/C] NM_175737 KLB Silent rs17618262 4 39449062 [T/C] NM_175737 KLB EXON Missense_Y906H rs7674617 4 39449595 [T/C] NM_175737 KLB Silent rs4975017 4 39450229 [A/C] NM_175737 KLB EXON Missense_Q1020K rs9995998 4 39452290 [T/C] NM_175737 KLB EXON Silent rs10517522 4 39453790 [A/G] rs2249563 4 39455378 [A/G] rs17510142 4 39455742 [A/G] rs2608830 4 39459154 [A/G] NM_000661,NM_001024921 RPL9,RPL9 Silent,Silent rs749915 4 39474868 [A/G] NM_001363700,NM_006859,NM_001278590,NM_194451 LIAS,LIAS,LIAS,LIAS Silent,Silent,Silent,Silent rs2259073 4 39475074 [A/C] NM_001363700,NM_006859,NM_001278590,NM_194451 LIAS,LIAS,LIAS,LIAS Silent,Silent,Silent,Silent rs17618369 4 39478164 [T/C] NM_001363700,NM_006859,NM_001278590,NM_194451 LIAS,LIAS,LIAS,LIAS Silent,Silent,Silent,Silent rs16995300 4 39478264 [A/G] NM_001363700,NM_006859,NM_001278590,NM_194451 LIAS,LIAS,LIAS,LIAS Silent,Silent,Silent,Silent rs1048140 4 39478832 [A/G] NM_001363700,NM_006859,NM_001278590,NM_194451 LIAS,LIAS,LIAS,LIAS EXON Silent,Silent,Silent,Silent rs2260645 4 39482684 [A/C] NR_026854 LOC401127 EXON Silent rs2687965 4 39491521 [A/G] rs2687964 4 39496272 [T/G] rs1450 4 39500514 [T/C] NM_001184700,NM_003359,NM_001184701 UGDH,UGDH,UGDH EXON Silent,Silent,Silent rs1046573 4 39501086 [A/G] NM_001184700,NM_003359,NM_001184701 UGDH,UGDH,UGDH EXON Silent,Silent,Silent rs9995522 4 39503196 [A/G] NM_001184700,NM_003359,NM_001184701 UGDH,UGDH,UGDH Silent,Silent,Silent rs7667766 4 39504305 [A/C] NM_001184700,NM_003359,NM_001184701 UGDH,UGDH,UGDH Silent,Silent,Silent rs1379819 4 39506144 [T/C] NM_001184700,NM_003359,NM_001184701 UGDH,UGDH,UGDH Silent,Silent,Silent rs10010387 4 39506940 [T/C] NM_001184700,NM_003359,NM_001184701 UGDH,UGDH,UGDH EXON Missense_H296R,Missense_H363R,Missense_H266R rs6832089 4 39507457 [T/C] NM_001184700,NM_003359,NM_001184701 UGDH,UGDH,UGDH Silent,Silent,Silent rs3177448 4 39510264 [A/G] NM_001184700,NM_003359,NM_001184701 UGDH,UGDH,UGDH EXON Synonymous_C209C,Synonymous_C276C,Synonymous_C179C rs10019532 4 39515736 [A/G] NM_001184700,NM_003359,NM_001184701 UGDH,UGDH,UGDH EXON Synonymous_D77D,Synonymous_D77D,Silent rs6817264 4 39518110 [T/G] NM_001184700,NM_003359,NM_001184701 UGDH,UGDH,UGDH Silent,Silent,Silent rs7669821 4 39522223 [T/C] NM_001184700,NM_003359,NM_001184701 UGDH,UGDH,UGDH Silent,Silent,Silent rs13129975 4 39526641 [A/G] NM_001184700,NM_003359,NM_001184701 UGDH,UGDH,UGDH Silent,Silent,Silent rs3755899 4 39529700 [A/G] NR_047679 UGDH-AS1 EXON Silent rs2381387 4 39531928 [A/G] NR_047679 UGDH-AS1 Silent rs13101951 4 39537738 [T/C] NR_047679 UGDH-AS1 Silent rs7692244 4 39538245 [A/G] NR_047679 UGDH-AS1 Silent rs4975021 4 39538357 [A/G] NR_047679 UGDH-AS1 Silent rs6833806 4 39548112 [A/G] NR_047679 UGDH-AS1 Silent rs11944799 4 39557864 [T/C] NR_047679,NM_001317896,NM_174921,NM_001317897 UGDH-AS1,SMIM14,SMIM14,SMIM14 Silent,Silent,Silent,Silent rs10019815 4 39559690 [T/C] NR_047679,NM_001317896,NM_174921,NM_001317897 UGDH-AS1,SMIM14,SMIM14,SMIM14 Silent,Silent,Silent,Silent rs28408009 4 39566499 [A/G] NR_047679,NM_001317896,NM_174921,NM_001317897 UGDH-AS1,SMIM14,SMIM14,SMIM14 Silent,Silent,Silent,Silent rs10004518 4 39572921 [A/G] NR_047679,NM_001317896,NM_174921,NM_001317897 UGDH-AS1,SMIM14,SMIM14,SMIM14 Silent,Silent,Silent,Silent rs17618779 4 39583823 [A/C] NR_047679,NM_001317896,NM_174921,NM_001317897 UGDH-AS1,SMIM14,SMIM14,SMIM14 Silent,Silent,Silent,Silent rs2890698 4 39586775 [T/G] NR_047679,NM_001317896,NM_174921,NM_001317897 UGDH-AS1,SMIM14,SMIM14,SMIM14 Silent,Silent,Silent,Silent rs7673664 4 39600010 [A/C] NM_001317896,NM_174921,NM_001317897 SMIM14,SMIM14,SMIM14 Silent,Silent,Silent rs7658676 4 39603132 [T/C] NM_001317896,NM_174921,NM_001317897 SMIM14,SMIM14,SMIM14 Silent,Silent,Silent rs6833494 4 39605669 [A/G] NM_001317896,NM_174921,NM_001317897 SMIM14,SMIM14,SMIM14 Silent,Silent,Silent rs10013417 4 39608977 [A/G] NM_001317896,NM_174921,NM_001317897 SMIM14,SMIM14,SMIM14 Silent,Silent,Silent rs900832 4 39610904 [T/C] NM_001317896,NM_174921,NM_001317897 SMIM14,SMIM14,SMIM14 Silent,Silent,Silent rs4554087 4 39611046 [A/G] NM_001317896,NM_174921,NM_001317897 SMIM14,SMIM14,SMIM14 Silent,Silent,Silent rs11096999 4 39614823 [T/C] NM_001317896,NM_174921,NM_001317897 SMIM14,SMIM14,SMIM14 Silent,Silent,Silent rs12512211 4 39616548 [A/G] NM_001317896,NM_174921,NM_001317897 SMIM14,SMIM14,SMIM14 Silent,Silent,Silent rs12500234 4 39619870 [T/G] NM_001317896,NM_174921,NM_001317897 SMIM14,SMIM14,SMIM14 Silent,Silent,Silent rs9306973 4 39627570 [T/C] NM_001317896,NM_174921,NM_001317897 SMIM14,SMIM14,SMIM14 Silent,Silent,Silent rs977385 4 39637826 [T/C] NM_001317896,NM_174921 SMIM14,SMIM14 Silent,Silent rs1484321 4 39641932 [T/G] rs13104353 4 39643536 [T/C] rs12510053 4 39648294 [A/G] rs11941588 4 39655457 [T/C] rs10856848 4 39657292 [T/C] rs1484322 4 39671142 [A/G] rs6531736 4 39686517 [A/G] rs4388095 4 39694314 [T/C] rs3912392 4 39698738 [A/G] rs3912391 4 39698824 [A/G] rs302941 4 39702089 [A/C] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K Silent,Silent,Silent,Silent,Silent,Silent rs2054718 4 39709947 [T/C] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K Silent,Silent,Silent,Silent,Silent,Silent rs10004937 4 39711872 [A/G] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K Silent,Silent,Silent,Silent,Silent,Silent rs4362831 4 39713134 [T/C] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K Silent,Silent,Silent,Silent,Silent,Silent rs10033569 4 39721239 [A/G] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K Silent,Silent,Silent,Silent,Silent,Silent rs159987 4 39737672 [A/C] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K Silent,Silent,Silent,Silent,Silent,Silent rs11939222 4 39744363 [A/G] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K Silent,Silent,Silent,Silent,Silent,Silent rs724256 4 39747907 [T/C] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K Silent,Silent,Silent,Silent,Silent,Silent rs725856 4 39748278 [A/G] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K Silent,Silent,Silent,Silent,Silent,Silent rs10517528 4 39748523 [T/C] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K Silent,Silent,Silent,Silent,Silent,Silent rs10014622 4 39752084 [A/G] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K Silent,Silent,Silent,Silent,Silent,Silent rs305827 4 39759989 [A/C] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K Silent,Silent,Silent,Silent,Silent,Silent rs438344 4 39760475 [T/C] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K Silent,Silent,Silent,Silent,Silent,Silent rs459274 4 39776955 [A/G] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K Silent,Silent,Silent,Silent,Silent,Silent rs17439268 4 39779376 [T/C] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K EXON Synonymous_S158S,Silent,Synonymous_S107S,Synonymous_S97S,Synonymous_S55S,Synonymous_S55S rs305112 4 39783729 [T/C] NM_005339,NM_001111112,NM_001111113,NM_001312646,NM_001312647,NM_001312648 UBE2K,UBE2K,UBE2K,UBE2K,UBE2K,UBE2K EXON Silent,Silent,Silent,Silent,Silent,Silent rs4263408 4 39785276 [T/C] rs192779 4 39788410 [T/C] rs6816573 4 39803506 [T/C] rs12499832 4 39803892 [A/G] rs11097004 4 39806505 [T/C] rs11732002 4 39810454 [T/C] rs403611 4 39812247 [T/C] rs4974949 4 39814064 [A/G] rs1003212 4 39818116 [T/C] rs1003213 4 39818522 [A/C] rs3733297 4 39822709 [A/G] rs305835 4 39822849 [T/C] rs3775078 4 39824758 [A/G] NM_001100399 PDS5A EXON Silent rs460334 4 39830157 [T/C] NM_001100399 PDS5A Silent rs7657667 4 39836933 [A/G] NM_001100399 PDS5A Silent rs50296 4 39837128 [T/C] NM_001100399 PDS5A Silent rs11723274 4 39843114 [T/C] NM_001100399 PDS5A Silent rs17619018 4 39854464 [T/C] NM_001100399 PDS5A Silent rs4547806 4 39864448 [A/G] NM_001100399 PDS5A Silent rs922749 4 39894988 [T/C] NM_001100399 PDS5A Silent rs6531748 4 39905415 [T/C] NM_001100399,NM_001100400 PDS5A,PDS5A Silent,Silent rs6839903 4 39921551 [A/G] NM_001100399,NM_001100400 PDS5A,PDS5A Silent,Silent rs2679780 4 39933442 [T/C] NM_001100399,NM_001100400 PDS5A,PDS5A Silent,Silent rs4440231 4 39935865 [T/C] NM_001100399,NM_001100400 PDS5A,PDS5A Silent,Silent rs2732063 4 39943056 [T/C] NM_001100399,NM_001100400 PDS5A,PDS5A Silent,Silent rs6815880 4 39943252 [A/G] NM_001100399,NM_001100400 PDS5A,PDS5A Silent,Silent rs13105733 4 39949502 [A/G] NM_001100399,NM_001100400 PDS5A,PDS5A Silent,Silent rs2732072 4 39984938 [A/C] rs7677857 4 39989369 [T/C] rs10213194 4 39999094 [A/G] rs557980 4 40007284 [T/C] rs7671594 4 40018632 [T/C] rs6838749 4 40022041 [A/G] rs7686844 4 40022511 [A/G] rs11097011 4 40035491 [T/C] rs7665844 4 40035613 [T/G] rs7660948 4 40042666 [T/G] rs17585937 4 40045687 [T/C] NR_027277 LOC344967 EXON Silent rs12503993 4 40047752 [A/G] NR_027277 LOC344967 Silent rs11737408 4 40048935 [T/C] NR_027277 LOC344967 Silent rs794016 4 40051064 [T/C] NR_027277 LOC344967 Silent rs2667720 4 40051678 [T/C] NR_027277 LOC344967 Silent rs6824761 4 40054818 [A/C] NR_027277 LOC344967 Silent rs1704155 4 40057909 [T/C] NR_027277 LOC344967 Silent rs7674515 4 40064563 [T/C] NM_018177,NM_001318359 N4BP2,N4BP2 Silent,Silent rs10017867 4 40071832 [T/G] NM_018177,NM_001318359 N4BP2,N4BP2 Silent,Silent rs7658672 4 40075187 [A/G] NM_018177,NM_001318359 N4BP2,N4BP2 Silent,Silent rs4974961 4 40097557 [T/C] NM_018177,NM_001318359 N4BP2,N4BP2 Silent,Silent rs813230 4 40097615 [T/G] NM_018177,NM_001318359 N4BP2,N4BP2 Silent,Silent rs17511668 4 40103767 [T/G] NM_018177,NM_001318359 N4BP2,N4BP2 EXON Missense_S101I,Missense_S21I rs10033188 4 40110337 [A/G] NM_018177,NM_001318359 N4BP2,N4BP2 Silent,Silent rs1706034 4 40120897 [A/G] NM_018177,NM_001318359 N4BP2,N4BP2 Silent,Silent rs794001 4 40121562 [A/G] NM_018177,NM_001318359 N4BP2,N4BP2 EXON Missense_D611N,Missense_D531N rs807787 4 40151656 [A/G] NM_018177,NM_001318359 N4BP2,N4BP2 Silent,Silent rs9998717 4 40158464 [A/G] NM_018177,NM_001318359 N4BP2,N4BP2 EXON Silent,Silent rs6531759 4 40162971 [A/G] rs12645398 4 40165305 [T/G] rs794018 4 40169424 [T/C] rs4974968 4 40172933 [T/C] rs7689782 4 40173103 [A/G] rs11946808 4 40176557 [T/G] rs1397933 4 40187537 [T/G] rs1397934 4 40187596 [A/G] rs12501987 4 40189325 [T/C] rs6819683 4 40190463 [T/C] rs6847288 4 40193332 [T/C] NM_001278368 RHOH Silent rs12643103 4 40194572 [T/C] NM_001278368 RHOH Silent rs1317577 4 40196549 [A/C] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent rs1996555 4 40198369 [T/C] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent rs1053504 4 40198842 [A/G] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4552473 4 40205742 [T/G] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17586314 4 40207190 [T/C] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2381499 4 40211997 [T/C] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4974974 4 40213628 [T/G] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7671812 4 40215687 [A/G] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2381501 4 40217706 [T/C] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13101295 4 40219896 [T/C] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6531762 4 40220469 [T/C] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1878893 4 40221675 [T/C] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6531763 4 40222303 [T/C] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2381502 4 40224043 [A/G] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7677758 4 40225912 [T/G] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11729556 4 40227671 [T/C] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7656219 4 40242433 [T/C] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13142049 4 40244347 [T/C] NM_001278368,NM_001278366,NM_001278365,NM_001278367,NM_001278364,NM_001278369,NM_001278362,NM_001278361,NM_001278359,NM_001278363,NM_004310,NM_001278360 RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH,RHOH EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4600925 4 40246416 [A/G] rs13130216 4 40246463 [A/C] rs7667815 4 40248956 [A/C] rs7669532 4 40255193 [T/C] rs16995675 4 40255411 [T/C] rs2381497 4 40255501 [A/G] rs17512296 4 40256245 [T/C] rs12513003 4 40259599 [T/C] rs13105678 4 40260379 [A/C] rs12643250 4 40262582 [A/G] rs12640505 4 40262814 [A/G] rs28802045 4 40265273 [T/C] rs9685160 4 40267780 [T/G] rs10022565 4 40274255 [T/G] rs9685080 4 40276103 [A/G] rs12512351 4 40277346 [A/G] rs9683756 4 40279534 [A/G] rs12186133 4 40283419 [A/G] rs12512323 4 40284434 [T/C] rs16995695 4 40285341 [T/C] rs9994274 4 40287396 [A/G] rs9684412 4 40291232 [T/C] rs11932152 4 40293158 [T/C] rs28655189 4 40301162 [T/C] rs6832151 4 40303633 [T/G] rs4444866 4 40307533 [T/C] rs12499947 4 40314351 [T/G] NR_121641 LINC02265 Silent rs4618346 4 40316298 [A/G] NR_121641 LINC02265 Silent rs6833121 4 40318449 [T/C] NR_121641 LINC02265 Silent rs6818783 4 40323397 [T/C] NR_121641,NR_121640 LINC02265,LINC02265 Silent,Silent rs11728461 4 40329548 [A/G] NR_121641,NR_121640 LINC02265,LINC02265 Silent,Silent rs7672694 4 40330079 [T/C] NR_121641,NR_121640 LINC02265,LINC02265 Silent,Silent rs7673930 4 40333521 [T/G] rs7679386 4 40333867 [T/C] rs6838680 4 40334852 [A/G] rs4469115 4 40336927 [A/C] rs10022491 4 40337908 [T/C] NM_017581 CHRNA9 EXON Synonymous_S43S rs10021263 4 40342618 [T/G] NM_017581 CHRNA9 Silent rs4861065 4 40344395 [T/C] NM_017581 CHRNA9 Silent rs4861307 4 40345239 [A/G] NM_017581 CHRNA9 Silent rs10029313 4 40350147 [T/G] NM_017581 CHRNA9 Silent rs7669882 4 40350651 [A/G] NM_017581 CHRNA9 Silent rs10029872 4 40350763 [T/C] NM_017581 CHRNA9 Silent rs10009228 4 40356422 [A/G] NM_017581 CHRNA9 EXON Missense_N442S rs6850417 4 40365870 [T/C] rs4861350 4 40367787 [T/C] rs10021851 4 40368848 [A/G] rs4861079 4 40371287 [A/G] rs1492506 4 40373000 [A/C] rs4861085 4 40373082 [A/G] rs1492505 4 40373150 [T/C] rs6447623 4 40377691 [A/G] rs10026108 4 40379061 [T/G] rs4861372 4 40379339 [T/G] rs902856 4 40380907 [A/G] rs1826394 4 40383379 [A/C] rs1955259 4 40384525 [A/C] rs17440690 4 40387873 [A/G] rs13107860 4 40391194 [T/G] rs17512490 4 40391816 [A/G] rs13123893 4 40393828 [A/G] rs278973 4 40396560 [A/G] rs11731787 4 40396697 [T/C] rs4447895 4 40397253 [A/C] rs4476635 4 40397913 [A/G] rs6832419 4 40401610 [T/C] rs4861106 4 40410479 [A/G] rs924639 4 40414829 [T/C] rs278933 4 40415109 [T/C] rs278927 4 40416124 [T/C] rs203273 4 40418670 [T/C] rs10007960 4 40419414 [A/G] rs9790641 4 40419876 [A/C] rs12505087 4 40420131 [A/G] rs278941 4 40420708 [A/G] rs17586828 4 40420763 [A/G] rs17512637 4 40420804 [T/C] rs4362858 4 40424213 [T/C] rs2008438 4 40424602 [T/G] rs278982 4 40426677 [A/G] NM_001098634,NM_019027 RBM47,RBM47 EXON Silent,Silent rs278981 4 40428010 [T/C] NM_001098634,NM_019027 RBM47,RBM47 EXON Missense_M565V,Missense_M496V rs278979 4 40431413 [T/C] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs3105208 4 40433155 [T/C] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs2307046 4 40438576 [A/G] NM_001098634,NM_019027 RBM47,RBM47 EXON Synonymous_G404G,Silent rs10755175 4 40443966 [T/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs10938155 4 40444292 [A/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs13129937 4 40445369 [A/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs10023957 4 40446425 [A/C] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs10018317 4 40447356 [A/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs7689954 4 40451394 [T/C] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs278956 4 40452114 [T/C] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs12647748 4 40453352 [A/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs7695920 4 40457354 [A/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs278949 4 40461712 [A/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs9790441 4 40462142 [A/C] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs10000300 4 40466547 [T/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs3105209 4 40473784 [A/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs278962 4 40475295 [T/C] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs16852239 4 40477729 [A/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs17441026 4 40477925 [A/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs380574 4 40482793 [T/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs278959 4 40488449 [T/C] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs4861170 4 40490465 [T/C] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs1847118 4 40491003 [T/C] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs10517543 4 40491187 [A/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs12641621 4 40491786 [A/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs278986 4 40494616 [T/C] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs4504294 4 40498421 [A/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs16852276 4 40503041 [T/C] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs6835176 4 40504552 [T/C] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs6857898 4 40506255 [A/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs6848632 4 40509521 [T/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs16852294 4 40513155 [T/C] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs364773 4 40515702 [T/G] NM_001098634,NM_019027 RBM47,RBM47 Silent,Silent rs430730 4 40519458 [A/G] NM_001098634 RBM47 Silent rs11737664 4 40528427 [T/C] NM_001098634 RBM47 Silent rs3114381 4 40533297 [T/C] NM_001098634 RBM47 Silent rs4632692 4 40535566 [A/G] NM_001098634 RBM47 Silent rs6847478 4 40546244 [T/C] NM_001098634 RBM47 Silent rs7667552 4 40548057 [T/C] NM_001098634 RBM47 Silent rs6817468 4 40549870 [T/C] NM_001098634 RBM47 Silent rs373103 4 40553177 [T/C] NM_001098634 RBM47 Silent rs11932270 4 40558019 [T/C] NM_001098634 RBM47 Silent rs6841429 4 40565469 [A/C] NM_001098634 RBM47 Silent rs16852342 4 40569727 [T/C] NM_001098634 RBM47 Silent rs17513191 4 40576393 [A/G] NM_001098634 RBM47 Silent rs10025907 4 40577228 [A/C] NM_001098634 RBM47 Silent rs3828531 4 40578403 [T/C] NM_001098634 RBM47 Silent rs16852377 4 40590349 [T/C] NM_001098634 RBM47 Silent rs17625986 4 40590908 [T/C] NM_001098634 RBM47 Silent rs4861060 4 40594008 [A/G] NM_001098634 RBM47 Silent rs12644323 4 40596439 [T/C] NM_001098634 RBM47 Silent rs1384035 4 40598634 [A/G] NM_001098634 RBM47 Silent rs17587482 4 40603055 [T/C] NM_001098634 RBM47 Silent rs6820328 4 40607397 [T/C] NM_001098634 RBM47 Silent rs10938275 4 40609305 [T/C] NM_001098634 RBM47 Silent rs11936786 4 40610732 [A/G] NM_001098634 RBM47 Silent rs6851689 4 40620852 [A/G] NM_001098634 RBM47 Silent rs13152696 4 40624014 [T/C] NM_001098634 RBM47 Silent rs13148961 4 40625135 [T/C] NM_001098634 RBM47 Silent rs6826994 4 40629220 [A/G] NM_001098634 RBM47 Silent rs7664412 4 40631309 [A/G] NM_001098634 RBM47 Silent rs12498424 4 40631476 [A/C] NM_001098634 RBM47 EXON Silent rs13132427 4 40635372 [T/C] rs10015679 4 40644376 [T/C] rs10032140 4 40647311 [T/G] rs7679359 4 40650498 [T/C] rs1552138 4 40651632 [A/G] rs4861297 4 40652510 [T/G] rs10032811 4 40660571 [T/C] rs7437008 4 40663704 [T/C] rs4861300 4 40668113 [T/C] rs6836880 4 40670323 [T/C] rs6836769 4 40677462 [T/C] rs2035385 4 40681370 [A/C] rs16852437 4 40683976 [A/G] rs2035381 4 40686808 [T/C] rs6835691 4 40687234 [T/C] rs6447325 4 40690285 [A/G] rs12498704 4 40690330 [A/G] rs6814199 4 40696983 [T/C] rs7661237 4 40698099 [A/G] rs12500580 4 40702239 [A/G] rs10004491 4 40704687 [A/G] rs10000266 4 40704872 [T/C] rs6830900 4 40708301 [A/G] rs6815557 4 40710034 [T/G] rs10009604 4 40710688 [T/C] rs10012870 4 40712344 [A/G] rs10008483 4 40712481 [A/C] rs790147 4 40722825 [T/C] rs2200061 4 40722850 [A/G] rs4516756 4 40726020 [A/C] rs790142 4 40730503 [A/G] rs11727143 4 40739635 [T/C] rs17513557 4 40746510 [T/C] rs7662655 4 40750705 [T/C] rs1545077 4 40754154 [T/C] NM_001330648,NM_024677 NSUN7,NSUN7 Silent,Silent rs10029833 4 40758525 [A/G] NM_001330648,NM_024677 NSUN7,NSUN7 Silent,Silent rs7699447 4 40771690 [T/C] NM_001330648,NM_024677 NSUN7,NSUN7 Silent,Silent rs10938385 4 40773665 [A/C] NM_001330648,NM_024677 NSUN7,NSUN7 Silent,Silent rs13106136 4 40777147 [A/G] NM_001330648,NM_024677 NSUN7,NSUN7 Silent,Silent rs2437323 4 40778162 [T/G] NM_001330648,NM_024677 NSUN7,NSUN7 EXON Missense_S308A,Missense_S308A rs2465568 4 40779968 [A/G] NM_001330648,NM_024677 NSUN7,NSUN7 Silent,Silent rs2437317 4 40792007 [A/G] NM_001330648,NM_024677 NSUN7,NSUN7 Silent,Silent rs2437309 4 40797693 [A/G] NM_001330648,NM_024677 NSUN7,NSUN7 Silent,Silent rs4861066 4 40810663 [A/G] NM_001330648,NM_024677 NSUN7,NSUN7 EXON Silent,Missense_T622A rs2261167 4 40810747 [A/G] NM_001330648,NM_024677 NSUN7,NSUN7 EXON Silent,Missense_K650E rs882733 4 40810978 [A/G] NM_001330648,NM_024677 NSUN7,NSUN7 EXON Silent,Silent rs11731472 4 40813714 [T/C] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13518 4 40815268 [T/G] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4861067 4 40823454 [T/G] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2341597 4 40827214 [T/C] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3816099 4 40832310 [T/C] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12501553 4 40833954 [A/C] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4861318 4 40835453 [A/G] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7666964 4 40836953 [A/G] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2437339 4 40837929 [A/G] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17587985 4 40838617 [T/C] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13135802 4 40839813 [T/C] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs765850 4 40842367 [T/C] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs719379 4 40842901 [T/C] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10517551 4 40843288 [A/G] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs746860 4 40857194 [T/C] NM_001330658,NM_001166053,NM_001166051,NM_001166054,NM_001330656,NM_001166050,NM_004307,NM_173075,NM_001166052 APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2465544 4 40860553 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs2437320 4 40867805 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs4861322 4 40874516 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs13132027 4 40881353 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs6817509 4 40885144 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs17442189 4 40886139 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs16852584 4 40887991 [A/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs6837256 4 40891780 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs11737809 4 40895018 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs6849533 4 40895132 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs13136284 4 40902988 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs6843173 4 40905726 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs4861330 4 40913247 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs10019646 4 40916975 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs13102449 4 40917488 [T/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs10938442 4 40917734 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs3922617 4 40926385 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7690478 4 40928213 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7657518 4 40928378 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs11733857 4 40931712 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs4861070 4 40933286 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs13125675 4 40938623 [T/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs13110219 4 40941473 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs4861073 4 40949691 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs3935357 4 40951828 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7658815 4 40953139 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs4861074 4 40953707 [A/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7697609 4 40956574 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs6832948 4 40958368 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs4861075 4 40965913 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs6855534 4 40967236 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs4501254 4 40973476 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs12511584 4 40977934 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs1032984 4 40982744 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs6816766 4 40985895 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs11735241 4 40987461 [T/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs10938478 4 40989048 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs1396110 4 40989826 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs9992186 4 40991215 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs10024411 4 40991885 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs6824724 4 40994063 [A/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs6832976 4 41003571 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs11942640 4 41015742 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 EXON Synonymous_E231E,Synonymous_E231E,Synonymous_E231E,Synonymous_E231E,Synonymous_E231E rs4861358 4 41015899 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 EXON Missense_R179Q,Missense_R179Q,Missense_R179Q,Missense_R179Q,Missense_R179Q rs11942164 4 41020544 [T/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs6842478 4 41020707 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs10033248 4 41030604 [A/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs11943259 4 41056241 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs6831604 4 41061049 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs1472869 4 41063203 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs9637561 4 41064528 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs13130182 4 41066388 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs10938518 4 41070095 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs16852774 4 41070449 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs13129535 4 41074389 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs3098914 4 41076288 [T/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7692276 4 41076426 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs1508067 4 41078183 [A/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7665863 4 41080894 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs17527299 4 41081976 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs9994615 4 41091835 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs2661661 4 41095181 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs10015784 4 41099221 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs10031772 4 41099333 [T/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7679772 4 41104347 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7655823 4 41115429 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs10026868 4 41122798 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7656191 4 41123834 [T/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs10516998 4 41126094 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs12499130 4 41131421 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs1110281 4 41136788 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs2880169 4 41140233 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs2585590 4 41144591 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs35125077 4 41149316 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs2661665 4 41151628 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7688017 4 41153134 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs2341855 4 41155960 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7674456 4 41156138 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs6447675 4 41158203 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7685881 4 41160956 [A/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs16852837 4 41165617 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs16851739 4 41173552 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7683197 4 41175148 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs17527711 4 41178263 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7659645 4 41181161 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs10022718 4 41186226 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs16852895 4 41190108 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs17443333 4 41193039 [A/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs10021613 4 41201819 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs11723385 4 41202789 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7683746 4 41203125 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs6835127 4 41204395 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs4455451 4 41204982 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs4634261 4 41205240 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs12503156 4 41205611 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs6842814 4 41205759 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7657549 4 41206430 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs17443381 4 41207339 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs17443388 4 41207624 [T/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7662463 4 41212540 [A/G] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs10003861 4 41212997 [A/C] NM_001330658,NM_001330656,NM_001166050,NM_004307,NM_173075 APBB2,APBB2,APBB2,APBB2,APBB2 Silent,Silent,Silent,Silent,Silent rs7695309 4 41218909 [A/C] rs6811777 4 41219792 [A/C] rs17528008 4 41220288 [A/G] rs17528036 4 41220816 [T/C] rs10938677 4 41222917 [T/C] NR_102709 UCHL1-AS1 Silent rs11735673 4 41224763 [A/G] NR_102709 UCHL1-AS1 Silent rs13101324 4 41225831 [T/C] NR_102709 UCHL1-AS1 Silent rs11941433 4 41225946 [A/G] NR_102709 UCHL1-AS1 Silent rs17528085 4 41231007 [T/C] NR_102709 UCHL1-AS1 Silent rs10019509 4 41247773 [T/C] NR_102709 UCHL1-AS1 Silent rs11944436 4 41247782 [T/C] NR_102709 UCHL1-AS1 Silent rs7693827 4 41254862 [T/C] NR_102709 UCHL1-AS1 Silent rs6447846 4 41258265 [T/C] NR_102709 UCHL1-AS1 Silent rs9321 4 41258978 [T/C] NM_004181 UCHL1 EXON Silent rs3775256 4 41266295 [T/C] NM_004181 UCHL1 Silent rs10517003 4 41269193 [A/G] NM_004181 UCHL1 Silent rs11728559 4 41272188 [T/G] rs7349641 4 41281031 [T/C] rs11945108 4 41283279 [T/C] rs4861393 4 41291280 [T/C] rs2219001 4 41291573 [T/C] rs12186184 4 41297430 [T/C] rs6828613 4 41299492 [A/G] rs11727269 4 41305694 [T/C] rs11724596 4 41308656 [T/C] rs11735648 4 41319962 [A/C] rs1377345 4 41322070 [A/G] rs16853063 4 41322091 [T/C] rs6838610 4 41322398 [A/G] rs16853108 4 41330982 [T/C] rs16853120 4 41335884 [T/C] rs13128229 4 41339317 [T/C] rs9637557 4 41340526 [T/C] rs7696120 4 41342264 [A/G] rs6447057 4 41343706 [T/C] rs4279250 4 41345419 [A/G] rs11721727 4 41346808 [A/G] rs11728170 4 41359624 [A/G] rs6834482 4 41359965 [T/C] rs7685339 4 41361984 [A/G] NM_001289124 LIMCH1 Silent rs4860991 4 41362506 [A/G] NM_001289124 LIMCH1 Silent rs2068783 4 41367089 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1869286 4 41373402 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1901747 4 41376347 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2342561 4 41377619 [A/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11735207 4 41378712 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16853153 4 41380887 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1377350 4 41387709 [A/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17628171 4 41395258 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7670762 4 41396631 [A/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13140742 4 41406130 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13142854 4 41406368 [A/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13118239 4 41406510 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6447065 4 41406966 [A/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6447066 4 41407668 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11938569 4 41407954 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12507919 4 41411424 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10938151 4 41411891 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4579156 4 41421908 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7675059 4 41430052 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4527518 4 41443113 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4560447 4 41447510 [T/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11737555 4 41448217 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7679031 4 41448957 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7665984 4 41457735 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7696363 4 41457923 [T/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4507392 4 41462412 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10470738 4 41464663 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6852190 4 41472234 [T/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6834608 4 41478144 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4349633 4 41485212 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13133735 4 41488228 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7696430 4 41490455 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13140281 4 41496140 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7689372 4 41499931 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4392535 4 41513423 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7671360 4 41521194 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12696762 4 41522232 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6447084 4 41531404 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6447085 4 41532328 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4293818 4 41543227 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4455452 4 41548580 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6447091 4 41551813 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10007810 4 41554364 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7656019 4 41556138 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4308395 4 41558580 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6850988 4 41572048 [A/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4540083 4 41585324 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6447096 4 41592743 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11729552 4 41594774 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10029589 4 41599965 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1105886 4 41611575 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10938153 4 41612137 [A/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10026359 4 41613931 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7659186 4 41614803 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4860998 4 41619643 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7657178 4 41635034 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Synonymous_T587T,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6830246 4 41639999 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4861123 4 41642833 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7694860 4 41645980 [T/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16853408 4 41652442 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 EXON Synonymous_T395T,Synonymous_T566T,Synonymous_T554T,Synonymous_T566T,Synonymous_T566T,Synonymous_T566T,Synonymous_T554T,Synonymous_T566T,Synonymous_T566T,Synonymous_T566T,Synonymous_T566T,Synonymous_T554T,Synonymous_T951T,Synonymous_T407T,Synonymous_T400T,Synonymous_T400T,Synonymous_T412T,Synonymous_T412T,Synonymous_T412T,Synonymous_T412T rs6811377 4 41656630 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6447103 4 41657672 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6821712 4 41659486 [A/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17590135 4 41659835 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7349706 4 41663002 [A/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17528897 4 41663621 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2304649 4 41664647 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10006144 4 41666173 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7671106 4 41669804 [T/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11734372 4 41673604 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 EXON Missense_M613T,Missense_M759T,Missense_M772T,Missense_M759T,Missense_M759T,Missense_M759T,Missense_M747T,Missense_M759T,Missense_M759T,Silent,Missense_M759T,Missense_M747T,Missense_M1144T,Missense_M600T,Missense_M593T,Missense_M593T,Missense_M605T,Missense_M605T,Missense_M605T,Missense_M605T rs7677377 4 41677213 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6837759 4 41679483 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16853448 4 41680321 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2304651 4 41681742 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6816179 4 41683212 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17590257 4 41686811 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2304652 4 41687911 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1061597 4 41691601 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 EXON Synonymous_A851A,Synonymous_A996A,Synonymous_A1010A,Synonymous_A1026A,Synonymous_A970A,Synonymous_A998A,Synonymous_A985A,Synonymous_A1023A,Synonymous_A1024A,Synonymous_A921A,Synonymous_A997A,Synonymous_A1011A,Synonymous_A1408A,Synonymous_A838A,Synonymous_A831A,Synonymous_A857A,Synonymous_A869A,Synonymous_A844A,Synonymous_A843A,Synonymous_A872A rs10027910 4 41699220 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7674006 4 41700107 [T/C] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1061562 4 41700361 [A/G] NM_001289124,NM_001330788,NM_001289122,NM_001330787,NM_001330789,NM_001112717,NM_001330792,NM_001330790,NM_014988,NM_001330784,NM_001112718,NM_001330791,NM_001330672,NM_001330786,NM_001112720,NM_001330674,NM_001330793,NM_001330982,NM_001112719,NM_001330983 LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1,LIMCH1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1020138 4 41703388 [A/G] rs12650313 4 41707093 [A/G] rs1439471 4 41710577 [T/C] rs6817913 4 41711689 [A/G] rs6847601 4 41712381 [T/C] rs9990806 4 41714272 [A/G] rs4861003 4 41714558 [A/G] rs1371301 4 41714627 [T/C] rs2043905 4 41718139 [T/C] rs16853557 4 41730976 [A/G] rs17529323 4 41733493 [A/C] rs11731281 4 41736897 [A/C] rs11733037 4 41737080 [T/C] rs17444900 4 41737309 [A/G] rs6826373 4 41746460 [T/C] NM_003924 PHOX2B EXON Silent rs16853571 4 41753130 [A/C] rs9283670 4 41758803 [T/C] rs1122992 4 41763403 [T/C] rs11729701 4 41764707 [T/C] rs6842806 4 41766595 [T/C] rs1439475 4 41771365 [T/C] rs5020056 4 41774747 [A/G] rs9999953 4 41782996 [A/G] rs1540499 4 41786214 [T/C] rs11931088 4 41787858 [T/C] rs1439483 4 41790191 [A/C] rs9997912 4 41790600 [A/G] rs1154598 4 41791492 [T/C] rs1898889 4 41793898 [T/C] rs6822112 4 41799127 [T/C] rs1371307 4 41801286 [T/C] rs6834302 4 41805686 [T/C] rs2043904 4 41807737 [A/G] rs7664468 4 41812109 [A/G] rs733778 4 41819608 [A/G] rs16853685 4 41821167 [A/G] rs714226 4 41826336 [A/G] rs7662010 4 41833632 [A/G] rs9998239 4 41834610 [T/C] rs4388122 4 41836529 [A/C] rs6838275 4 41841334 [A/C] rs6839810 4 41850006 [T/C] rs6447118 4 41855573 [T/G] rs4861149 4 41882964 [A/G] NR_104143 LINC00682 Silent rs9993759 4 41883483 [T/C] NR_104143 LINC00682 Silent rs6821891 4 41889237 [T/C] rs7660832 4 41889667 [A/G] rs10517012 4 41892087 [T/C] rs1983138 4 41901368 [A/G] rs11933062 4 41930732 [T/C] rs4861151 4 41933626 [A/G] rs16853775 4 41940132 [A/C] NM_018126 TMEM33 Silent rs6830514 4 41956313 [A/G] NM_018126 TMEM33 EXON Silent rs1507086 4 41956413 [T/C] NM_018126 TMEM33 EXON Silent rs1043343 4 41962491 [A/C] NM_018126 TMEM33 EXON Silent rs11942311 4 41965136 [A/G] rs2660343 4 41977766 [A/G] rs2660320 4 41984118 [T/C] NM_001029955 DCAF4L1 EXON Synonymous_S103S rs2660335 4 41985689 [T/C] NM_001029955 DCAF4L1 EXON Silent rs2581439 4 41986857 [A/G] NM_001029955 DCAF4L1 EXON Silent rs2581438 4 41987892 [A/G] NM_001029955 DCAF4L1 EXON Silent rs16853864 4 41992458 [A/G] rs1047626 4 42003671 [A/G] NM_006345 SLC30A9 EXON Missense_M50V rs2581451 4 42006057 [T/C] NM_006345 SLC30A9 Silent rs2581441 4 42011970 [A/G] NM_006345 SLC30A9 Silent rs15857 4 42022464 [A/C] NM_006345 SLC30A9 EXON Synonymous_G122G rs3827590 4 42031437 [A/G] NM_006345 SLC30A9 Silent rs34936554 4 42031922 [T/G] NM_006345 SLC30A9 Silent rs9654068 4 42032966 [A/G] NM_006345 SLC30A9 Silent rs9291209 4 42033153 [T/C] NM_006345 SLC30A9 Silent rs17530357 4 42066311 [A/G] NM_006345 SLC30A9 Silent rs10938175 4 42066378 [A/G] NM_006345 SLC30A9 Silent rs4619931 4 42074633 [A/G] NM_006345 SLC30A9 Silent rs6447123 4 42078241 [A/G] NM_006345 SLC30A9 Silent rs11051 4 42089177 [A/G] NM_006345 SLC30A9 EXON Silent rs7655320 4 42099799 [A/G] rs6447127 4 42107100 [T/G] rs7697558 4 42110719 [T/C] rs7682049 4 42112734 [T/C] rs7677472 4 42114671 [T/G] NM_207406,NM_001159547 BEND4,BEND4 EXON Silent,Silent rs17446061 4 42115810 [T/C] NM_207406,NM_001159547 BEND4,BEND4 EXON Silent,Silent rs6847380 4 42116116 [T/C] NM_207406,NM_001159547 BEND4,BEND4 EXON Silent,Silent rs4861163 4 42117173 [T/C] NM_207406,NM_001159547 BEND4,BEND4 EXON Silent,Silent rs16854020 4 42117559 [A/G] NM_207406,NM_001159547 BEND4,BEND4 EXON Silent,Silent rs16854027 4 42120105 [A/G] NM_207406,NM_001159547 BEND4,BEND4 Silent,Silent rs16854033 4 42121223 [T/C] NM_207406,NM_001159547 BEND4,BEND4 Silent,Silent rs3810840 4 42121774 [A/G] NM_207406,NM_001159547 BEND4,BEND4 Silent,Silent rs4132888 4 42125621 [A/G] NM_207406,NM_001159547 BEND4,BEND4 Silent,Silent rs6447131 4 42129997 [T/C] NM_207406,NM_001159547 BEND4,BEND4 Silent,Silent rs4861164 4 42141388 [T/C] NM_207406,NM_001159547 BEND4,BEND4 Silent,Silent rs6848386 4 42146657 [T/C] NM_207406,NM_001159547 BEND4,BEND4 Silent,Silent rs6447133 4 42161427 [T/C] rs4299622 4 42164386 [A/G] rs13151738 4 42165799 [T/C] rs7672382 4 42174810 [A/G] rs6827980 4 42183596 [A/G] rs6812348 4 42193790 [T/G] rs6852533 4 42195808 [A/G] rs13119304 4 42201089 [T/G] rs7697139 4 42205552 [T/C] rs7674997 4 42206574 [T/C] rs9999533 4 42211367 [T/C] rs4861168 4 42218575 [T/C] rs7667510 4 42219146 [A/G] rs16854081 4 42220880 [T/C] rs6826969 4 42223934 [A/G] rs17629772 4 42224011 [T/C] rs13117610 4 42226924 [A/G] rs17530621 4 42227497 [T/G] rs7664670 4 42230777 [T/C] rs4861175 4 42237898 [A/G] rs729466 4 42241036 [A/G] rs729467 4 42241138 [A/G] rs729179 4 42241485 [T/G] rs989313 4 42243086 [A/C] rs9291212 4 42249776 [A/G] rs17530831 4 42250342 [T/C] rs4861178 4 42251630 [A/G] rs17530845 4 42253010 [A/G] rs1542686 4 42256594 [A/G] rs12507844 4 42265464 [T/G] rs2171423 4 42276583 [A/G] rs4861181 4 42281042 [T/C] rs6823142 4 42291959 [A/C] rs10026772 4 42301184 [A/G] NR_134668 LOC105374428 EXON Silent rs2632695 4 42313720 [T/C] NR_134668 LOC105374428 Silent rs2262643 4 42314717 [T/C] NR_134668 LOC105374428 Silent rs3103190 4 42322946 [A/G] NR_134668 LOC105374428 Silent rs2632689 4 42326215 [T/C] NR_134668 LOC105374428 Silent rs2632690 4 42326229 [T/G] NR_134668 LOC105374428 Silent rs748360 4 42331579 [T/C] NR_134668 LOC105374428 Silent rs1023993 4 42336312 [A/C] NR_134668 LOC105374428 Silent rs1565111 4 42344051 [T/C] NR_134668 LOC105374428 Silent rs3103200 4 42357010 [T/C] NR_134668 LOC105374428 Silent rs2719949 4 42358088 [A/G] NR_134668 LOC105374428 Silent rs10025341 4 42363367 [T/G] NR_134668 LOC105374428 Silent rs9291216 4 42368901 [T/C] NR_134668 LOC105374428 Silent rs6832142 4 42373005 [A/G] NR_134668 LOC105374428 Silent rs923309 4 42376356 [T/G] NR_134668 LOC105374428 Silent rs3103207 4 42376769 [T/C] NR_134668 LOC105374428 Silent rs3109630 4 42377390 [A/G] NR_134668 LOC105374428 Silent rs2719947 4 42384915 [A/G] NR_134668 LOC105374428 Silent rs6447159 4 42389740 [A/C] NR_134668 LOC105374428 Silent rs11735318 4 42394408 [T/G] rs3103218 4 42395984 [T/C] rs7676862 4 42397387 [T/C] rs3103222 4 42401416 [T/G] NM_001080505 SHISA3 Silent rs7665824 4 42411553 [T/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 EXON Silent,Silent rs10008830 4 42415501 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs4481266 4 42417526 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs3935448 4 42423197 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs9994372 4 42428210 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs7665008 4 42431550 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs7688175 4 42432089 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs7695984 4 42433734 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs10034088 4 42443009 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs6855691 4 42446079 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs7684005 4 42449874 [T/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs10034082 4 42451770 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs13139219 4 42453303 [A/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs17531575 4 42453514 [A/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs13103298 4 42455837 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs12647640 4 42466641 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs10517027 4 42472966 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs10000708 4 42475352 [T/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs6447164 4 42481276 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs3935029 4 42484396 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs9291218 4 42490680 [A/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs4861030 4 42496713 [A/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs10034756 4 42497919 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs4280770 4 42499224 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs3792687 4 42509101 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 EXON Missense_T673M,Missense_T658M rs10517038 4 42511242 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs6819929 4 42511312 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs4526008 4 42517211 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs4395543 4 42552434 [A/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs10805104 4 42556540 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs17593128 4 42559530 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs6447170 4 42567615 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs2061526 4 42570934 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs1460354 4 42571666 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs12502828 4 42574373 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs16854520 4 42574630 [A/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs2290870 4 42576420 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs13148015 4 42576472 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs2290868 4 42577517 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs10013589 4 42583029 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs16854546 4 42585853 [T/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs1080248 4 42587201 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs7672084 4 42597060 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs9291219 4 42607736 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs1870611 4 42612831 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs10938199 4 42622148 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs16854618 4 42622525 [A/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs2306004 4 42627836 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs16854620 4 42628889 [T/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs16854624 4 42629038 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 EXON Synonymous_L46L,Synonymous_L46L rs1563849 4 42632678 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs898500 4 42639186 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs1460362 4 42644312 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs6851867 4 42646252 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs1380754 4 42646677 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs2612520 4 42647802 [T/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs17448506 4 42648398 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs3101246 4 42649935 [T/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs7693131 4 42652004 [A/G] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs10938202 4 42652337 [T/C] NM_006095,NM_001105529 ATP8A1,ATP8A1 Silent,Silent rs2575568 4 42660891 [A/C] rs2612507 4 42661922 [T/C] rs13133617 4 42662283 [A/G] rs2575551 4 42665092 [T/C] rs12501388 4 42673312 [A/G] rs2575484 4 42676234 [A/G] rs882642 4 42683596 [T/C] rs2575453 4 42685758 [A/C] rs1460352 4 42690604 [A/G] rs7441772 4 42694179 [T/G] rs2575548 4 42697553 [A/G] rs2612468 4 42706128 [T/C] rs2612467 4 42706804 [T/C] rs2612538 4 42707463 [T/G] rs2612533 4 42712114 [T/C] rs2345467 4 42712959 [A/C] rs12502362 4 42714879 [A/G] rs2612530 4 42718502 [T/C] rs2085782 4 42720868 [T/C] rs2575509 4 42723259 [A/G] rs16854849 4 42726713 [T/G] rs2252994 4 42726868 [T/C] rs2575566 4 42727694 [A/C] rs1563850 4 42735553 [A/G] rs2575529 4 42735847 [A/G] rs13146994 4 42748194 [A/G] rs12330944 4 42749176 [A/G] rs2345904 4 42753188 [A/G] rs13101579 4 42788309 [A/G] rs12331684 4 42790130 [A/G] rs12650389 4 42796127 [T/C] rs2575513 4 42796294 [T/C] rs7697036 4 42797274 [T/C] rs2575514 4 42797768 [A/C] rs6847936 4 42809169 [T/G] rs3099914 4 42810102 [A/C] rs17449493 4 42813098 [T/C] rs1562839 4 42813800 [A/G] rs1450914 4 42816051 [A/C] rs13130624 4 42817301 [T/C] rs1450917 4 42819241 [A/G] rs1584622 4 42821511 [T/C] rs10470752 4 42825862 [A/G] rs17637607 4 42826929 [A/G] rs1562840 4 42838348 [T/C] rs4861040 4 42839254 [A/G] rs2122648 4 42840063 [T/C] rs4861041 4 42840819 [T/G] rs17594783 4 42845691 [A/G] rs10938222 4 42847692 [T/C] rs12642552 4 42847901 [A/C] rs17534138 4 42848697 [A/G] rs2881215 4 42851723 [A/G] rs1993059 4 42856894 [A/G] rs9985652 4 42858453 [A/G] rs12643533 4 42858855 [T/C] rs11728299 4 42864378 [T/C] rs13141599 4 42869436 [A/G] rs10023065 4 42869937 [T/G] rs10033259 4 42870369 [A/G] rs716693 4 42873798 [A/G] rs1562837 4 42874286 [A/C] rs11937866 4 42877064 [A/G] rs7696133 4 42877463 [A/G] rs1562842 4 42877802 [T/C] rs1993062 4 42881014 [A/G] rs17637745 4 42881197 [T/C] rs7655156 4 42883195 [A/C] rs2122651 4 42889160 [T/C] rs10517057 4 42900562 [A/C] NM_001080476 GRXCR1 Silent rs7656477 4 42902654 [A/G] NM_001080476 GRXCR1 Silent rs10517055 4 42902734 [A/G] NM_001080476 GRXCR1 Silent rs1450906 4 42906100 [A/G] NM_001080476 GRXCR1 Silent rs10018588 4 42907803 [A/C] NM_001080476 GRXCR1 Silent rs2122647 4 42908357 [T/G] NM_001080476 GRXCR1 Silent rs4583798 4 42909520 [A/C] NM_001080476 GRXCR1 Silent rs1450911 4 42914565 [A/C] NM_001080476 GRXCR1 Silent rs1450904 4 42919356 [T/G] NM_001080476 GRXCR1 Silent rs6830507 4 42919640 [A/G] NM_001080476 GRXCR1 Silent rs980779 4 42924425 [T/C] NM_001080476 GRXCR1 Silent rs7439983 4 42924853 [A/G] NM_001080476 GRXCR1 Silent rs10517062 4 42933496 [T/G] NM_001080476 GRXCR1 Silent rs1450932 4 42937881 [A/G] NM_001080476 GRXCR1 Silent rs7667015 4 42939381 [A/G] NM_001080476 GRXCR1 Silent rs6818868 4 42942050 [T/C] NM_001080476 GRXCR1 Silent rs9992691 4 42959499 [A/C] NM_001080476 GRXCR1 Silent rs10938227 4 42964453 [A/G] NM_001080476 GRXCR1 Silent rs10007716 4 42969550 [T/C] NM_001080476 GRXCR1 Silent rs2118030 4 42975329 [T/C] NM_001080476 GRXCR1 Silent rs10010155 4 42977657 [A/G] NM_001080476 GRXCR1 Silent rs13103779 4 42989086 [A/G] NM_001080476 GRXCR1 Silent rs13130490 4 42999072 [A/G] NM_001080476 GRXCR1 Silent rs1436478 4 43007627 [T/C] NM_001080476 GRXCR1 Silent rs11941642 4 43014010 [T/C] NM_001080476 GRXCR1 Silent rs1160755 4 43015770 [A/C] NM_001080476 GRXCR1 Silent rs1545101 4 43019669 [T/C] NM_001080476 GRXCR1 Silent rs10000073 4 43022222 [T/C] NM_001080476 GRXCR1 Silent rs10938230 4 43025255 [A/C] NM_001080476 GRXCR1 Silent rs4861050 4 43032612 [A/G] NM_001080476 GRXCR1 EXON Silent rs16855251 4 43032966 [A/G] rs11736676 4 43041018 [A/G] rs4512035 4 43042976 [A/G] rs9997524 4 43052186 [A/C] rs920152 4 43068604 [T/C] rs7672044 4 43074301 [T/G] rs6850625 4 43082956 [A/C] rs6447224 4 43106517 [T/C] rs6845571 4 43112381 [T/C] rs12498763 4 43112603 [T/G] rs1583540 4 43115315 [T/C] rs1436485 4 43124710 [A/G] rs1436487 4 43125020 [A/G] rs6851917 4 43128814 [A/G] rs12503562 4 43134215 [T/C] rs6857139 4 43136289 [A/G] rs6843495 4 43139616 [T/C] rs4861254 4 43140284 [A/G] rs4861052 4 43145074 [A/G] rs10213019 4 43147514 [A/G] rs7688320 4 43148953 [A/G] rs4257684 4 43149962 [T/C] rs13114756 4 43161354 [A/G] rs10000600 4 43162852 [T/C] rs12646066 4 43162880 [T/C] rs13120255 4 43165259 [A/G] rs10009982 4 43165682 [T/C] rs6447253 4 43180186 [T/C] rs13113494 4 43181231 [T/G] rs10938254 4 43186618 [A/G] rs4263432 4 43191706 [T/C] rs4270612 4 43192298 [A/C] rs13108021 4 43197962 [A/G] rs12505258 4 43199190 [A/G] rs4290920 4 43205099 [T/C] rs12650928 4 43214691 [A/G] rs7666204 4 43216821 [T/C] rs12648489 4 43220821 [T/C] rs10938264 4 43221563 [T/G] rs11932535 4 43226893 [T/C] rs4543153 4 43229735 [T/C] rs4488964 4 43232359 [A/G] rs12645109 4 43232462 [A/C] rs4447896 4 43232759 [A/C] rs1442864 4 43246631 [A/G] rs12500109 4 43252905 [A/G] rs10938268 4 43254582 [A/G] rs7683961 4 43254889 [T/C] rs17638446 4 43279788 [T/C] rs16855687 4 43282074 [T/C] rs10004063 4 43284037 [T/C] rs11934444 4 43284304 [A/G] rs17595833 4 43285567 [T/C] rs11730763 4 43293318 [T/C] rs1442870 4 43296003 [A/G] rs12505465 4 43296814 [T/C] rs16855764 4 43298226 [A/G] rs17595974 4 43305565 [T/C] rs10029778 4 43305896 [T/C] rs1442855 4 43323916 [T/C] rs12510088 4 43324563 [T/C] rs6828560 4 43328707 [T/C] rs4861277 4 43331637 [A/C] rs6854231 4 43344992 [T/C] rs1398200 4 43350370 [A/C] rs17596310 4 43352577 [A/G] rs920693 4 43353022 [T/C] rs17596399 4 43360332 [A/G] rs7657677 4 43363694 [T/G] rs16855942 4 43365592 [A/G] rs671254 4 43394110 [T/C] rs599290 4 43410470 [T/C] rs17639240 4 43424930 [T/G] rs654313 4 43428426 [T/C] rs2347044 4 43432922 [T/C] rs6447271 4 43438919 [A/G] rs9994327 4 43440641 [A/G] rs528582 4 43442648 [T/C] rs1631011 4 43456817 [T/G] rs10021165 4 43468632 [T/C] NR_146993 LINC02383 Silent rs10000949 4 43469328 [A/G] NR_146993 LINC02383 Silent rs6447273 4 43481992 [T/C] NR_146993 LINC02383 Silent rs7694215 4 43484250 [T/C] NR_146993 LINC02383 Silent rs473726 4 43502330 [A/C] rs4861284 4 43520590 [T/G] rs13117635 4 43523299 [T/C] rs13136012 4 43523444 [A/G] rs9992804 4 43526808 [A/G] rs16856147 4 43533668 [T/C] rs11939659 4 43561857 [T/C] rs6816987 4 43564831 [T/C] rs5014637 4 43567623 [A/C] rs6447283 4 43595446 [T/C] rs9291237 4 43599872 [A/G] rs6813203 4 43609761 [T/C] rs2013357 4 43634967 [A/C] rs985774 4 43635055 [A/G] rs10011190 4 43648726 [A/G] rs16856331 4 43652124 [A/G] rs16856334 4 43654867 [A/C] rs12649203 4 43656260 [A/G] rs1962872 4 43664997 [A/G] rs16856368 4 43665919 [A/G] rs13138756 4 43666123 [T/C] rs13137462 4 43666139 [T/G] rs1594921 4 43680722 [T/C] rs1648082 4 43685461 [A/G] rs1713517 4 43689885 [T/G] rs7659996 4 43702376 [T/C] rs1648078 4 43705885 [T/C] rs1369175 4 43714649 [A/G] rs1550046 4 43722400 [A/C] rs7340999 4 43731044 [T/C] rs1834429 4 43738519 [A/C] rs1369177 4 43739772 [T/C] rs1583408 4 43751098 [T/C] rs2347345 4 43761213 [A/G] rs3849587 4 43772856 [A/G] rs2162128 4 43775511 [A/G] rs1713511 4 43777370 [A/G] rs10938307 4 43781839 [T/C] rs2347347 4 43786489 [A/G] rs1648095 4 43791881 [T/C] rs10938308 4 43792690 [T/C] rs2678759 4 43798822 [T/G] rs2613157 4 43810738 [A/G] rs10938310 4 43815025 [A/G] rs4695155 4 43823868 [T/C] rs1460627 4 43827201 [A/G] rs1460613 4 43832158 [T/G] rs7675193 4 43840138 [A/C] rs2715650 4 43840953 [A/G] rs6853428 4 43851228 [T/C] rs2722147 4 43853032 [T/C] rs1460608 4 43853511 [T/G] rs9790652 4 43854629 [A/G] rs17537488 4 43857651 [T/G] rs7660461 4 43857879 [A/C] rs2722136 4 43866979 [T/C] rs1460614 4 43872019 [A/C] rs6834369 4 43888799 [A/G] rs10008858 4 43891003 [T/C] rs898573 4 43900285 [T/C] rs6828926 4 43900434 [T/C] rs11931045 4 43903247 [A/G] rs2347669 4 43907884 [A/G] rs7679442 4 43911686 [A/G] rs12644632 4 43913465 [A/G] rs12513382 4 43914603 [T/C] rs1037855 4 43927834 [A/G] rs4426822 4 43934098 [A/G] rs11737698 4 43935421 [A/C] rs11934528 4 43941075 [A/G] rs11725899 4 43941731 [A/G] rs1870645 4 43944901 [T/C] rs2881695 4 43951966 [T/C] rs1460639 4 43952928 [A/G] rs2085806 4 43958230 [T/G] rs4385106 4 43960180 [T/C] rs991382 4 43963518 [A/G] rs1460634 4 43968054 [T/C] rs17598761 4 43971237 [A/G] rs7700023 4 43974714 [T/C] rs7694541 4 43982267 [A/G] rs10010379 4 43982530 [A/G] rs11942913 4 43986534 [A/G] rs10517091 4 44015175 [A/G] rs4323141 4 44016954 [A/G] rs13107489 4 44024196 [A/G] rs4348131 4 44029345 [A/G] rs4695394 4 44041667 [T/C] rs12331900 4 44042710 [T/C] rs6858778 4 44050101 [A/G] rs4540086 4 44051144 [T/C] rs7693710 4 44091711 [T/C] rs4695447 4 44093499 [T/G] rs7666961 4 44100094 [T/C] rs12498358 4 44106293 [A/C] rs12511977 4 44109192 [T/C] rs6840648 4 44112560 [T/C] rs7689034 4 44121146 [T/C] rs6813741 4 44133596 [T/G] rs9996682 4 44137398 [T/C] rs6853456 4 44144150 [T/C] rs6828553 4 44149564 [A/C] rs7666732 4 44152250 [T/C] rs13116771 4 44152766 [T/C] rs7673940 4 44161454 [T/C] rs1027201 4 44167271 [T/C] rs10517096 4 44175373 [T/C] rs35939382 4 44175533 [A/G] rs4694999 4 44186433 [A/G] NM_198353 KCTD8 Silent rs4695701 4 44187682 [T/C] NM_198353 KCTD8 Silent rs6811002 4 44196006 [T/C] NM_198353 KCTD8 Silent rs17641486 4 44210076 [A/G] NM_198353 KCTD8 Silent rs10028283 4 44218748 [T/C] NM_198353 KCTD8 Silent rs10938330 4 44246039 [T/G] NM_198353 KCTD8 Silent rs11941070 4 44260690 [T/C] NM_198353 KCTD8 Silent rs1038767 4 44273405 [T/C] NM_198353 KCTD8 Silent rs10007704 4 44276751 [T/C] NM_198353 KCTD8 Silent rs1948314 4 44280236 [A/G] NM_198353 KCTD8 Silent rs6853031 4 44298245 [T/C] NM_198353 KCTD8 Silent rs3963342 4 44300248 [T/C] NM_198353 KCTD8 Silent rs1490452 4 44308547 [T/C] NM_198353 KCTD8 Silent rs17538903 4 44315428 [T/C] NM_198353 KCTD8 Silent rs17599591 4 44329589 [A/C] NM_198353 KCTD8 Silent rs17599605 4 44334829 [T/C] NM_198353 KCTD8 Silent rs2703833 4 44341530 [A/G] NM_198353 KCTD8 Silent rs10517102 4 44348032 [T/C] NM_198353 KCTD8 Silent rs11732997 4 44351013 [A/G] NM_198353 KCTD8 Silent rs10517103 4 44351941 [T/C] NM_198353 KCTD8 Silent rs6447330 4 44358412 [A/G] NM_198353 KCTD8 Silent rs13132322 4 44363703 [T/C] NM_198353 KCTD8 Silent rs7674464 4 44372045 [A/G] NM_198353 KCTD8 Silent rs17653012 4 44377494 [T/C] NM_198353 KCTD8 Silent rs16856866 4 44381632 [A/C] NM_198353 KCTD8 Silent rs4407541 4 44381959 [T/G] NM_198353 KCTD8 Silent rs17461093 4 44396930 [A/G] NM_198353 KCTD8 Silent rs17599994 4 44400111 [T/C] NM_198353 KCTD8 Silent rs11726514 4 44401672 [A/G] NM_198353 KCTD8 Silent rs17461113 4 44402331 [A/G] NM_198353 KCTD8 Silent rs16856879 4 44407133 [T/C] NM_198353 KCTD8 Silent rs4695718 4 44412937 [T/C] NM_198353 KCTD8 Silent rs7664938 4 44414165 [A/G] NM_198353 KCTD8 Silent rs16856898 4 44416300 [T/C] NM_198353 KCTD8 Silent rs11931753 4 44423496 [A/G] NM_198353 KCTD8 Silent rs4312793 4 44424487 [T/C] NM_198353 KCTD8 Silent rs17461197 4 44428788 [A/G] NM_198353 KCTD8 Silent rs10938341 4 44433864 [T/C] NM_198353 KCTD8 Silent rs16856919 4 44435648 [A/C] NM_198353 KCTD8 Silent rs13144404 4 44435685 [T/C] NM_198353 KCTD8 Silent rs16856929 4 44437034 [A/C] NM_198353 KCTD8 Silent rs4695004 4 44438741 [T/C] NM_198353 KCTD8 Silent rs4419508 4 44443246 [T/C] NM_198353 KCTD8 Silent rs10024393 4 44445943 [T/C] NM_198353 KCTD8 Silent rs17461326 4 44451821 [A/G] rs13133564 4 44452305 [A/G] rs17653191 4 44459005 [A/G] rs10938345 4 44463404 [T/C] rs4610370 4 44465870 [T/G] rs9291244 4 44466809 [A/G] rs7697982 4 44481810 [A/G] rs1439381 4 44486350 [A/C] rs11939023 4 44494356 [A/G] rs10009992 4 44496791 [A/G] rs10019946 4 44520666 [A/G] rs1595656 4 44528928 [T/C] rs2118934 4 44530236 [A/C] rs1371238 4 44531529 [A/G] rs6838754 4 44532032 [A/G] rs1439382 4 44536354 [A/G] rs1439389 4 44542952 [T/C] rs11736162 4 44545381 [A/G] rs10517108 4 44553869 [T/C] rs1371235 4 44557599 [T/C] rs1898858 4 44560636 [A/G] rs6858760 4 44564747 [A/G] rs12509197 4 44575415 [T/C] rs1371237 4 44580312 [A/G] rs13140831 4 44580804 [A/G] rs10938353 4 44582487 [A/G] rs13138228 4 44592060 [A/C] rs11725120 4 44603369 [T/G] rs17571930 4 44607572 [A/G] rs920349 4 44608871 [A/G] rs6844093 4 44610348 [T/C] rs16857230 4 44613461 [A/G] rs11736925 4 44616283 [A/G] rs1439365 4 44616723 [T/C] rs1439377 4 44628607 [T/C] NM_182592 YIPF7 Silent rs1439375 4 44636193 [A/G] NM_182592 YIPF7 Silent rs12641939 4 44642995 [T/C] NM_182592 YIPF7 Silent rs6447363 4 44648797 [A/G] NM_182592 YIPF7 Silent rs2348353 4 44652030 [T/C] NM_182592 YIPF7 EXON Missense_A54T rs1388311 4 44654002 [A/G] rs17600990 4 44656408 [T/C] rs16857321 4 44659472 [T/C] rs12639722 4 44660248 [T/C] rs6826194 4 44663178 [A/G] rs2306993 4 44684438 [A/G] NM_001345868,NM_001345869,NM_001345867,NM_021927 GUF1,GUF1,GUF1,GUF1 Silent,Silent,Silent,Silent rs12499960 4 44687401 [A/G] NM_001345868,NM_001345869,NM_001345867,NM_021927 GUF1,GUF1,GUF1,GUF1 Silent,Silent,Silent,Silent rs10470742 4 44690071 [T/C] NM_001345868,NM_001345869,NM_001345867,NM_021927 GUF1,GUF1,GUF1,GUF1 EXON Missense_T329I,Missense_T5I,Missense_T5I,Missense_T329I rs6812211 4 44701750 [A/C] NM_001345868,NM_001345869,NM_001345867,NM_021927 GUF1,GUF1,GUF1,GUF1 EXON Silent,Silent,Silent,Silent rs6854175 4 44704435 [A/G] NM_001270881,NM_001270880,NR_073095,NR_073094,NM_138335 GNPDA2,GNPDA2,GNPDA2,GNPDA2,GNPDA2 EXON Silent,Silent,Silent,Silent,Silent rs1491302 4 44709695 [T/C] NM_001270881,NM_001270880,NR_073095,NR_073094,NM_138335 GNPDA2,GNPDA2,GNPDA2,GNPDA2,GNPDA2 Silent,Silent,Silent,Silent,Silent rs1547525 4 44710346 [A/G] NM_001270881,NM_001270880,NR_073095,NR_073094,NM_138335 GNPDA2,GNPDA2,GNPDA2,GNPDA2,GNPDA2 Silent,Silent,Silent,Silent,Silent rs1907487 4 44724533 [A/G] NM_001270881,NM_001270880,NR_073095,NR_073094,NM_138335 GNPDA2,GNPDA2,GNPDA2,GNPDA2,GNPDA2 Silent,Silent,Silent,Silent,Silent rs12640665 4 44726671 [T/C] NM_001270881,NM_001270880,NR_073095,NR_073094,NM_138335 GNPDA2,GNPDA2,GNPDA2,GNPDA2,GNPDA2 Silent,Silent,Silent,Silent,Silent rs2172143 4 44727988 [A/C] NM_001270881,NM_001270880,NR_073095,NR_073094,NM_138335 GNPDA2,GNPDA2,GNPDA2,GNPDA2,GNPDA2 Silent,Silent,Silent,Silent,Silent rs1532194 4 44732143 [A/G] rs2046909 4 44770222 [A/C] rs6828324 4 44778348 [A/G] rs1873526 4 44781238 [T/G] rs1491313 4 44785389 [T/G] rs1491311 4 44785999 [T/C] rs1491328 4 44802221 [A/G] rs6845593 4 44803683 [A/G] rs7673194 4 44804733 [A/G] rs11943498 4 44826773 [T/C] rs6816452 4 44849345 [T/C] rs17601614 4 44852361 [A/G] rs1497008 4 44859443 [T/C] rs10517119 4 44859711 [A/G] rs10517120 4 44859761 [T/C] rs6835058 4 44864639 [T/C] rs4694786 4 44868270 [A/G] rs4694787 4 44868481 [A/G] rs6810444 4 44870978 [T/C] rs2348805 4 44871619 [A/G] rs16857647 4 44876213 [A/G] rs10019381 4 44897864 [T/G] rs7692626 4 44897911 [A/C] rs4695056 4 44898738 [T/G] rs7675825 4 44904578 [T/C] rs10938371 4 44905275 [T/C] rs1107676 4 44906396 [T/G] rs2348518 4 44908179 [A/C] rs1496991 4 44909241 [A/G] rs10461071 4 44916027 [A/G] rs11932803 4 44918770 [T/C] rs7661117 4 44924735 [A/G] rs12513234 4 44928851 [A/G] rs17654704 4 44930650 [A/G] rs1472395 4 44935266 [T/G] rs9291254 4 44939860 [T/C] rs2173109 4 44954288 [T/C] rs2882027 4 44954941 [T/C] rs17573940 4 44955488 [A/G] rs10020374 4 44955964 [T/C] rs1908807 4 44964929 [T/C] rs17608495 4 44976703 [A/G] rs10021452 4 44982038 [A/G] rs12645733 4 44983208 [T/C] rs6854974 4 44985301 [T/C] rs4560452 4 44989500 [T/C] rs34929711 4 45002987 [T/C] rs4695069 4 45007208 [T/G] rs10018053 4 45015525 [T/C] rs7666773 4 45016808 [A/G] rs13142647 4 45018583 [A/G] rs7442192 4 45023201 [A/G] rs10032600 4 45025291 [T/C] rs13140100 4 45030609 [A/G] rs10155504 4 45031256 [T/C] rs4305551 4 45035197 [A/G] rs12643633 4 45041473 [T/G] rs7682029 4 45045543 [T/C] rs6844797 4 45059561 [T/C] rs4306991 4 45068593 [T/C] rs1512320 4 45077656 [T/G] rs17608635 4 45079676 [A/G] rs17470661 4 45083659 [A/G] rs12640145 4 45102488 [T/C] rs16858015 4 45117658 [T/C] rs17655141 4 45119572 [A/G] rs7689003 4 45125825 [A/G] rs979580 4 45127762 [T/G] rs7659184 4 45133240 [A/G] rs6845132 4 45139673 [T/C] rs1996023 4 45164637 [T/G] rs13130484 4 45175691 [T/C] rs16858082 4 45175804 [T/C] rs12641981 4 45179883 [T/C] rs10027118 4 45181744 [A/G] rs10938397 4 45182527 [A/G] rs1858410 4 45191856 [T/G] rs12509470 4 45192865 [T/C] rs16858167 4 45213605 [T/C] rs1392615 4 45224500 [A/G] rs348548 4 45230009 [T/C] rs16858270 4 45253157 [A/C] rs1500493 4 45254893 [T/C] rs17637290 4 45255852 [T/G] rs1500495 4 45263659 [A/G] rs12505580 4 45274282 [T/G] rs6818687 4 45285463 [A/C] rs12643061 4 45299977 [T/C] rs4267772 4 45308763 [T/C] rs16858373 4 45321022 [T/C] rs1500488 4 45338240 [A/G] rs16858386 4 45339702 [T/C] rs6858099 4 45342647 [A/G] rs1392612 4 45346690 [T/C] rs10027285 4 45348941 [A/G] rs2349125 4 45348959 [T/C] rs6826745 4 45362545 [T/C] rs1476295 4 45374305 [A/G] rs12508162 4 45374989 [T/C] rs12503671 4 45385709 [T/C] rs12500516 4 45392037 [T/C] rs13107382 4 45401173 [A/G] rs10009466 4 45427255 [A/G] rs1486617 4 45431010 [A/G] rs10020709 4 45441814 [A/G] rs10028314 4 45448030 [T/C] rs17637825 4 45469812 [T/C] rs6851779 4 45487679 [A/G] rs17595063 4 45491047 [A/G] rs990676 4 45496981 [A/G] rs16858591 4 45503395 [T/C] rs16858604 4 45507374 [T/C] rs9992791 4 45522585 [A/G] rs1552419 4 45525885 [T/C] rs10025115 4 45548754 [A/G] rs840193 4 45556947 [T/C] rs1620380 4 45588229 [T/C] rs6829634 4 45612701 [A/G] rs10004397 4 45626526 [A/C] rs2061231 4 45638847 [T/C] rs12640483 4 45702046 [T/C] rs10015537 4 45705727 [A/G] rs1456507 4 45717849 [A/G] rs1456508 4 45720024 [T/C] rs1598654 4 45725524 [T/C] rs13109781 4 45732500 [T/C] rs957858 4 45737256 [T/G] rs1389040 4 45745877 [A/G] rs9994814 4 45757412 [T/C] rs4623052 4 45767897 [A/G] rs13123812 4 45772213 [T/C] rs6847304 4 45792228 [T/C] rs6838450 4 45795589 [A/C] rs1492839 4 45795895 [A/G] rs7670127 4 45800337 [A/G] rs988543 4 45811691 [A/G] rs2035906 4 45817327 [T/C] rs11735495 4 45829948 [T/C] rs6826668 4 45839740 [A/G] rs10032936 4 45843672 [A/G] rs1353014 4 45851084 [A/G] rs11721867 4 45858464 [A/G] rs13136580 4 45859948 [A/G] rs2349443 4 45863268 [T/C] rs7692404 4 45875599 [T/C] rs7685154 4 45880408 [A/G] rs1492837 4 45882448 [A/G] rs1353013 4 45896156 [T/C] rs4554111 4 45900198 [A/G] rs7690208 4 45900199 [T/C] rs9994137 4 45923348 [T/C] rs1394346 4 45924834 [T/C] rs16858975 4 45927431 [T/C] rs6817621 4 45929172 [A/G] rs9997632 4 45930890 [A/G] rs7668279 4 45939413 [T/C] rs7699135 4 45956676 [T/C] rs13127070 4 45956780 [A/G] rs7698346 4 45956988 [A/G] rs924837 4 45972653 [A/G] rs6855343 4 45976727 [T/C] rs2089154 4 45982196 [A/G] rs1566854 4 45995759 [T/C] rs10030781 4 46025913 [T/C] rs10014198 4 46027834 [G/C] rs10938423 4 46038274 [T/C] NM_173536 GABRG1 EXON Silent rs7666844 4 46039718 [T/C] NM_173536 GABRG1 EXON Silent rs1497567 4 46040738 [A/G] NM_173536 GABRG1 EXON Silent rs1497568 4 46040758 [A/G] NM_173536 GABRG1 EXON Silent rs17639008 4 46041957 [T/C] NM_173536 GABRG1 EXON Silent rs7683876 4 46042083 [A/G] NM_173536 GABRG1 EXON Silent rs993677 4 46055478 [T/C] NM_173536 GABRG1 Silent rs1391174 4 46072596 [T/C] NM_173536 GABRG1 Silent rs976156 4 46086060 [T/C] NM_173536 GABRG1 EXON Synonymous_T88T rs13109156 4 46093249 [T/C] NM_173536 GABRG1 Silent rs1497575 4 46093351 [A/G] NM_173536 GABRG1 Silent rs13120165 4 46101549 [A/G] NM_173536 GABRG1 Silent rs1497559 4 46105928 [A/G] NM_173536 GABRG1 Silent rs11942023 4 46118134 [T/C] NM_173536 GABRG1 Silent rs6842243 4 46150637 [T/C] rs10033451 4 46152332 [T/C] rs12500958 4 46170805 [A/C] rs13434697 4 46183224 [A/G] rs522636 4 46227847 [T/C] rs16859210 4 46236454 [T/C] rs478179 4 46238737 [T/G] rs511310 4 46240004 [A/G] rs16859227 4 46250605 [T/C] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 EXON Silent,Silent,Silent,Silent rs3822051 4 46256712 [T/C] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs534459 4 46256805 [A/G] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs526805 4 46263391 [A/C] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs279871 4 46305733 [T/C] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs1808851 4 46311447 [T/C] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs16859306 4 46315980 [T/C] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs183962 4 46316688 [T/C] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs3775282 4 46321863 [T/C] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs279845 4 46329723 [T/A] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs189957 4 46346679 [A/G] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs16859325 4 46352868 [A/C] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs12647055 4 46355479 [T/C] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs1442060 4 46366067 [A/G] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs3849591 4 46368641 [T/G] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs9291283 4 46371833 [A/G] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs13152740 4 46381221 [A/G] NM_001286827,NM_001114175,NM_000807,NM_001330690 GABRA2,GABRA2,GABRA2,GABRA2 Silent,Silent,Silent,Silent rs894269 4 46393612 [T/C] rs1025852 4 46400331 [A/G] rs6847731 4 46402152 [A/G] rs10461072 4 46413251 [T/G] rs996129 4 46422329 [T/C] rs16859399 4 46447918 [T/G] rs16859407 4 46455805 [A/G] rs17598295 4 46474853 [A/G] rs4293822 4 46498640 [T/G] rs4695161 4 46504523 [A/G] rs12508420 4 46524214 [A/G] rs10517161 4 46541559 [A/G] rs4645250 4 46551757 [A/G] rs4576046 4 46557025 [T/C] rs12513214 4 46576065 [T/C] rs4541476 4 46596239 [T/C] rs10938449 4 46625274 [A/G] rs10019070 4 46627357 [A/G] rs10029664 4 46635167 [T/C] rs10470769 4 46683061 [T/C] rs9291289 4 46685463 [A/G] rs4538458 4 46690369 [A/G] rs10024620 4 46691120 [A/G] rs6853207 4 46721833 [T/C] rs9790574 4 46734901 [T/C] rs4395475 4 46742649 [T/C] NM_130902 COX7B2 Silent rs11945399 4 46750333 [T/C] NM_130902 COX7B2 Silent rs10938457 4 46759314 [A/G] NM_130902 COX7B2 Silent rs4478161 4 46789898 [T/C] NM_130902 COX7B2 Silent rs10938458 4 46796836 [A/G] NM_130902 COX7B2 Silent rs4129828 4 46805796 [A/C] NM_130902 COX7B2 Silent rs12503660 4 46838259 [A/C] NM_130902 COX7B2 Silent rs2221854 4 46868162 [A/C] NM_130902 COX7B2 Silent rs9291290 4 46878105 [T/G] NM_130902 COX7B2 Silent rs9291291 4 46878219 [A/G] NM_130902 COX7B2 Silent rs10938462 4 46890143 [T/C] NM_130902 COX7B2 Silent rs7683552 4 46898265 [T/C] NM_130902 COX7B2 Silent rs1512128 4 46899077 [A/C] NM_130902 COX7B2 Silent rs13119670 4 46903491 [T/C] NM_130902 COX7B2 Silent rs11722432 4 46919749 [T/G] rs7678338 4 46922107 [T/C] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 EXON Silent,Silent,Silent rs10033500 4 46922688 [T/C] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 EXON Silent,Silent,Silent rs9291296 4 46922950 [A/G] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 EXON Silent,Silent,Silent rs9291297 4 46923108 [A/C] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 EXON Silent,Silent,Silent rs953380 4 46925813 [A/G] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 EXON Silent,Silent,Silent rs17599074 4 46927124 [T/C] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 EXON Silent,Silent,Silent rs1398174 4 46927145 [T/G] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 EXON Silent,Silent,Silent rs10004905 4 46927886 [T/C] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 EXON Silent,Silent,Silent rs16859700 4 46929104 [T/C] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 EXON Silent,Silent,Silent rs1028005 4 46941018 [A/G] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 Silent,Silent,Silent rs1512130 4 46952471 [A/G] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 Silent,Silent,Silent rs16859751 4 46953059 [T/C] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 Silent,Silent,Silent rs10015891 4 46957305 [A/G] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 Silent,Silent,Silent rs2221855 4 46961617 [T/G] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 Silent,Silent,Silent rs6844842 4 46963222 [T/C] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 Silent,Silent,Silent rs2055943 4 46967279 [A/C] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 Silent,Silent,Silent rs3792208 4 46974038 [A/C] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 Silent,Silent,Silent rs17641660 4 46982218 [T/G] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 Silent,Silent,Silent rs10517174 4 46982826 [A/G] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 Silent,Silent,Silent rs6851503 4 46985429 [A/G] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 Silent,Silent,Silent rs7694035 4 46985750 [A/C] NM_001204267,NM_000809,NM_001204266 GABRA4,GABRA4,GABRA4 Silent,Silent,Silent rs13151759 4 46995653 [T/G] NM_000809 GABRA4 EXON Silent rs2055940 4 46997913 [A/G] rs7683042 4 46999235 [A/G] rs6447520 4 47002378 [T/C] rs1159315 4 47003076 [T/C] rs1512144 4 47004037 [A/G] rs1512142 4 47004305 [A/G] rs13139021 4 47006399 [T/C] rs3934674 4 47013138 [A/G] rs4521322 4 47018520 [T/C] rs6814188 4 47019621 [T/C] rs12646764 4 47033226 [A/C] rs13116355 4 47039315 [A/G] NM_000812 GABRB1 Silent rs4317179 4 47045377 [T/C] NM_000812 GABRB1 Silent rs4574382 4 47047786 [A/G] NM_000812 GABRB1 Silent rs4315750 4 47051185 [A/C] NM_000812 GABRB1 Silent rs10015366 4 47057759 [A/G] NM_000812 GABRB1 Silent rs4597805 4 47064496 [A/C] NM_000812 GABRB1 Silent rs4600895 4 47069259 [A/C] NM_000812 GABRB1 Silent rs4694834 4 47079408 [A/G] NM_000812 GABRB1 Silent rs4396968 4 47089184 [T/C] NM_000812 GABRB1 Silent rs7663591 4 47097460 [A/G] NM_000812 GABRB1 Silent rs1866990 4 47101223 [A/G] NM_000812 GABRB1 Silent rs10517178 4 47102993 [T/C] NM_000812 GABRB1 Silent rs971354 4 47103115 [A/G] NM_000812 GABRB1 Silent rs7696916 4 47105600 [A/C] NM_000812 GABRB1 Silent rs1372491 4 47109360 [A/G] NM_000812 GABRB1 Silent rs12645665 4 47132261 [A/C] NM_000812 GABRB1 Silent rs3906823 4 47142218 [T/C] NM_000812 GABRB1 Silent rs2351299 4 47143365 [T/G] NM_000812 GABRB1 Silent rs1442097 4 47150997 [T/C] NM_000812 GABRB1 Silent rs6827925 4 47156545 [A/G] NM_000812 GABRB1 Silent rs17599816 4 47164556 [A/G] NM_000812 GABRB1 Silent rs989808 4 47166781 [T/G] NM_000812 GABRB1 Silent rs11940530 4 47167315 [T/C] NM_000812 GABRB1 Silent rs7673824 4 47174149 [T/C] NM_000812 GABRB1 Silent rs2119779 4 47175700 [T/C] NM_000812 GABRB1 Silent rs1561776 4 47181795 [A/G] NM_000812 GABRB1 Silent rs10004181 4 47203863 [T/C] NM_000812 GABRB1 Silent rs6839998 4 47211774 [T/G] NM_000812 GABRB1 Silent rs1372497 4 47222338 [T/C] NM_000812 GABRB1 Silent rs12501459 4 47223353 [A/G] NM_000812 GABRB1 Silent rs16860076 4 47225740 [A/G] NM_000812 GABRB1 Silent rs1372498 4 47226204 [A/G] NM_000812 GABRB1 Silent rs1372499 4 47226436 [A/G] NM_000812 GABRB1 Silent rs17539445 4 47231416 [T/G] NM_000812 GABRB1 Silent rs17539459 4 47234200 [A/G] NM_000812 GABRB1 Silent rs2165612 4 47239175 [T/C] NM_000812 GABRB1 Silent rs7695365 4 47243813 [T/C] NM_000812 GABRB1 Silent rs10026884 4 47272392 [A/G] NM_000812 GABRB1 Silent rs17653240 4 47277298 [T/C] NM_000812 GABRB1 Silent rs9997710 4 47279522 [A/G] NM_000812 GABRB1 Silent rs9999619 4 47282643 [T/C] NM_000812 GABRB1 Silent rs17653263 4 47284233 [A/G] NM_000812 GABRB1 Silent rs2078610 4 47289054 [T/G] NM_000812 GABRB1 Silent rs4396966 4 47291135 [T/C] NM_000812 GABRB1 Silent rs6284 4 47322219 [A/C] NM_000812 GABRB1 EXON Synonymous_I179I rs3775534 4 47322382 [A/G] NM_000812 GABRB1 Silent rs7660843 4 47325991 [A/C] NM_000812 GABRB1 Silent rs7665508 4 47347289 [A/G] NM_000812 GABRB1 Silent rs4588429 4 47350872 [A/G] NM_000812 GABRB1 Silent rs6447550 4 47356566 [T/C] NM_000812 GABRB1 Silent rs6832172 4 47359371 [A/G] NM_000812 GABRB1 Silent rs6848790 4 47365544 [T/C] NM_000812 GABRB1 Silent rs10517184 4 47367125 [A/G] NM_000812 GABRB1 Silent rs17461905 4 47369065 [T/C] NM_000812 GABRB1 Silent rs11733050 4 47375312 [A/G] NM_000812 GABRB1 Silent rs4695224 4 47375627 [A/C] NM_000812 GABRB1 Silent rs4695226 4 47382920 [A/C] NM_000812 GABRB1 Silent rs6813436 4 47390820 [A/G] NM_000812 GABRB1 Silent rs3822113 4 47406635 [T/C] NM_000812 GABRB1 Silent rs6290 4 47408838 [T/C] NM_000812 GABRB1 EXON Synonymous_A325A rs13106855 4 47413522 [A/G] NM_000812 GABRB1 Silent rs16860198 4 47415812 [T/G] NM_000812 GABRB1 Silent rs17600665 4 47417586 [A/G] NM_000812 GABRB1 Silent rs10155404 4 47421325 [A/G] NM_000812 GABRB1 Silent rs10028945 4 47428305 [A/G] NM_000812 GABRB1 EXON Silent rs13102764 4 47430927 [A/G] rs4403019 4 47435315 [T/C] rs4450898 4 47436404 [A/G] rs10470771 4 47436571 [A/G] rs7689984 4 47444186 [A/G] rs10020578 4 47450445 [A/G] rs7685214 4 47452883 [A/C] NM_017845,NM_001329668 COMMD8,COMMD8 EXON Silent,Silent rs4635794 4 47463221 [A/G] NM_017845,NM_001329668 COMMD8,COMMD8 Silent,Silent rs13115740 4 47465847 [A/C] rs4585276 4 47467186 [T/G] rs2276 4 47476876 [T/C] rs6841768 4 47477177 [T/G] rs10021832 4 47483119 [T/C] rs4438736 4 47484645 [T/C] rs4508853 4 47485111 [T/C] rs4292304 4 47496962 [T/C] NM_020453 ATP10D Silent rs6813123 4 47503661 [T/C] NM_020453 ATP10D Silent rs4235151 4 47504161 [T/G] NM_020453 ATP10D Silent rs6829033 4 47508540 [A/C] NM_020453 ATP10D Silent rs10000432 4 47511781 [T/C] NM_020453 ATP10D Silent rs6817661 4 47526473 [T/G] NM_020453 ATP10D Silent rs9999398 4 47533601 [A/G] NM_020453 ATP10D Silent rs7674353 4 47533838 [T/C] NM_020453 ATP10D Silent rs12374260 4 47536566 [T/C] NM_020453 ATP10D Silent rs4296657 4 47541849 [A/G] NM_020453 ATP10D Silent rs4694852 4 47543891 [T/C] NM_020453 ATP10D Silent rs4694853 4 47544012 [T/C] NM_020453 ATP10D Silent rs10938490 4 47544947 [T/C] NM_020453 ATP10D Silent rs12502323 4 47548254 [A/G] NM_020453 ATP10D Silent rs4695248 4 47555196 [T/C] NM_020453 ATP10D Silent rs4694857 4 47558132 [A/G] NM_020453 ATP10D Silent rs11729411 4 47560163 [A/C] NM_020453 ATP10D EXON Synonymous_I769I rs4298115 4 47560386 [T/C] NM_020453 ATP10D Silent rs10212763 4 47562899 [A/G] NM_020453 ATP10D Silent rs13127414 4 47567579 [A/G] NM_020453 ATP10D Silent rs6854584 4 47568964 [A/G] NM_020453 ATP10D Silent rs17462252 4 47570876 [A/G] NM_020453 ATP10D EXON Missense_S959N rs4694858 4 47571914 [T/C] NM_020453 ATP10D Silent rs10004038 4 47573660 [A/G] NM_020453 ATP10D Silent rs6840205 4 47577455 [A/G] NM_020453 ATP10D Silent rs16851681 4 47578971 [A/G] NM_020453 ATP10D EXON Missense_R1183K rs17572095 4 47583291 [A/G] NM_020453 ATP10D Silent rs1058793 4 47584046 [A/G] NM_020453 ATP10D EXON Missense_V1240I rs7694197 4 47584682 [A/G] NM_020453 ATP10D Silent rs1316874 4 47589203 [A/G] NM_020453 ATP10D EXON Synonymous_T1307T rs2351790 4 47589299 [A/C] NM_020453 ATP10D Silent rs10021442 4 47589896 [A/G] NM_020453 ATP10D Silent rs16860409 4 47590147 [A/C] NM_020453 ATP10D Silent rs12641970 4 47593532 [A/G] NM_020453 ATP10D EXON Silent rs11947521 4 47593976 [A/G] NM_020453 ATP10D EXON Silent rs3811829 4 47594220 [A/G] NM_020453 ATP10D EXON Silent rs4695253 4 47596632 [T/C] NM_001278585,NM_006587 CORIN,CORIN EXON Silent,Silent rs3749585 4 47597590 [A/G] NM_001278585,NM_006587 CORIN,CORIN EXON Silent,Silent rs12650894 4 47602599 [T/G] NM_001278585,NM_006587 CORIN,CORIN Silent,Silent rs6832495 4 47609664 [A/G] NM_001278585,NM_006587 CORIN,CORIN Silent,Silent rs4695256 4 47614900 [A/G] NM_001278585,NM_006587 CORIN,CORIN Silent,Silent rs10017276 4 47622480 [T/C] NM_001278585,NM_006587 CORIN,CORIN Silent,Silent rs12331639 4 47623275 [A/G] NM_001278585,NM_006587 CORIN,CORIN Silent,Silent rs13105718 4 47631983 [A/G] NM_001278585,NM_006587 CORIN,CORIN Silent,Silent rs7680097 4 47637456 [T/C] NM_001278585,NM_006587 CORIN,CORIN Silent,Silent rs13306287 4 47645264 [T/C] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN EXON Missense_Q552R,Missense_Q656R,Missense_Q619R rs11934749 4 47667064 [T/C] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN EXON Missense_H421R,Missense_H525R,Missense_H488R rs6815552 4 47669751 [T/C] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs4695267 4 47672301 [T/C] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs12643755 4 47674150 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs13105608 4 47676436 [T/C] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN EXON Missense_D340G,Missense_D444G,Missense_D407G rs16860547 4 47676489 [T/C] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN EXON Synonymous_Q322Q,Synonymous_Q426Q,Synonymous_Q389Q rs12644230 4 47679566 [T/C] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs10517195 4 47682174 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN EXON Silent,Synonymous_S372S,Silent rs13118104 4 47683429 [T/C] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs7661217 4 47688064 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs10028293 4 47691035 [T/C] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs6447580 4 47691710 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs16860598 4 47696975 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs16860610 4 47701872 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs10517198 4 47705578 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs13122612 4 47709613 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs2352143 4 47722145 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs13135920 4 47731360 [T/C] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs17601663 4 47735503 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs3886430 4 47739293 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs6849926 4 47742275 [T/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs10008014 4 47745012 [T/C] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs4473628 4 47752554 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs9999023 4 47769066 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs9996629 4 47775469 [T/C] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs4591570 4 47782849 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs12508460 4 47816387 [T/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs12645164 4 47817004 [A/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs16860658 4 47821397 [T/G] NM_001278585,NM_006587,NM_001278586 CORIN,CORIN,CORIN Silent,Silent,Silent rs1866688 4 47833809 [T/C] NM_001278585,NM_006587,NM_001278586,NR_125881,NR_125880 CORIN,CORIN,CORIN,LOC101927179,LOC101927179 Silent,Silent,Silent,Silent,Silent rs2033897 4 47834151 [A/G] NM_001278585,NM_006587,NM_001278586,NR_125881,NR_125880 CORIN,CORIN,CORIN,LOC101927179,LOC101927179 Silent,Silent,Silent,Silent,Silent rs893864 4 47837883 [A/G] NM_001278585,NM_006587,NM_001278586,NR_125881,NR_125880 CORIN,CORIN,CORIN,LOC101927179,LOC101927179 Silent,Silent,Silent,Silent,Silent rs893863 4 47838050 [A/G] NM_001278585,NM_006587,NM_001278586,NR_125881,NR_125880 CORIN,CORIN,CORIN,LOC101927179,LOC101927179 Silent,Silent,Silent,Silent,Silent rs2289433 4 47839929 [T/C] NM_001278585,NM_006587,NM_001278586,NR_125881,NR_125880 CORIN,CORIN,CORIN,LOC101927179,LOC101927179 EXON Missense_C13Y,Missense_C13Y,Missense_C13Y,Silent,Silent rs1062858 4 47843628 [T/C] NR_125881,NR_125880 LOC101927179,LOC101927179 Silent,Silent rs1440221 4 47845920 [A/G] NR_125881,NR_125880 LOC101927179,LOC101927179 Silent,Silent rs10025104 4 47855999 [T/C] NR_125881,NR_125880,NM_001278623,NM_152995,NR_103795,NM_001278624 LOC101927179,LOC101927179,NFXL1,NFXL1,NFXL1,NFXL1 Silent,Silent,Silent,Silent,Silent,Silent rs2033895 4 47868889 [A/G] NR_125881,NR_125880,NM_001278623,NM_152995,NR_103795,NM_001278624 LOC101927179,LOC101927179,NFXL1,NFXL1,NFXL1,NFXL1 Silent,Silent,Silent,Silent,Silent,Silent rs11733734 4 47885085 [T/G] NR_125881,NR_125880,NM_001278623,NM_152995,NR_103795,NM_001278624 LOC101927179,LOC101927179,NFXL1,NFXL1,NFXL1,NFXL1 Silent,Silent,Silent,Silent,Silent,Silent rs16860723 4 47887393 [T/C] NR_125881,NR_125880,NM_001278623,NM_152995,NR_103795,NM_001278624 LOC101927179,LOC101927179,NFXL1,NFXL1,NFXL1,NFXL1 Silent,Silent,Silent,Silent,Silent,Silent rs2053404 4 47887536 [T/C] NR_125881,NR_125880,NM_001278623,NM_152995,NR_103795,NM_001278624 LOC101927179,LOC101927179,NFXL1,NFXL1,NFXL1,NFXL1 EXON Silent,Silent,Synonymous_A601A,Synonymous_A601A,Silent,Synonymous_A601A rs6818556 4 47887991 [A/G] NR_125881,NR_125880,NM_001278623,NM_152995,NR_103795,NM_001278624 LOC101927179,LOC101927179,NFXL1,NFXL1,NFXL1,NFXL1 EXON Silent,Silent,Synonymous_T523T,Synonymous_T523T,Silent,Synonymous_T523T rs4475122 4 47901259 [A/G] NM_001278623,NM_152995,NR_103795,NM_001278624 NFXL1,NFXL1,NFXL1,NFXL1 Silent,Silent,Silent,Silent rs4695306 4 47913127 [T/C] NM_001278623,NM_152995,NR_103795,NM_001278624 NFXL1,NFXL1,NFXL1,NFXL1 Silent,Silent,Silent,Silent rs6833320 4 47917441 [T/C] NR_125879 LOC101927157 Silent rs4695315 4 47936543 [T/C] NR_125879 LOC101927157 Silent rs9291318 4 47937727 [A/G] NR_125879 LOC101927157 Silent rs28642966 4 47945295 [T/C] NR_125879,NM_001142564,NM_000087 LOC101927157,CNGA1,CNGA1 EXON Silent,Missense_D187N,Missense_D118N rs4695317 4 47950256 [T/C] NR_125879,NM_001142564,NM_000087 LOC101927157,CNGA1,CNGA1 Silent,Silent,Silent rs1012844 4 47952676 [A/G] NR_125879,NM_001142564,NM_000087 LOC101927157,CNGA1,CNGA1 Silent,Silent,Silent rs17573709 4 47955758 [T/C] NR_125879,NM_001142564,NM_000087 LOC101927157,CNGA1,CNGA1 Silent,Silent,Silent rs12640473 4 47965547 [T/C] NR_125879,NM_001142564,NM_000087 LOC101927157,CNGA1,CNGA1 Silent,Silent,Silent rs4695318 4 47979063 [A/C] NR_125879,NM_001142564,NM_000087 LOC101927157,CNGA1,CNGA1 Silent,Silent,Silent rs1507920 4 47984635 [T/C] NR_125879,NM_000087 LOC101927157,CNGA1 Silent,Silent rs167692 4 47986088 [T/C] NR_125879,NM_000087 LOC101927157,CNGA1 Silent,Silent rs17654757 4 47990809 [A/C] NR_125879,NM_000087 LOC101927157,CNGA1 Silent,Silent rs11932474 4 47997253 [A/G] NM_000087 CNGA1 Silent rs321631 4 48018229 [A/G] rs321633 4 48018529 [T/C] rs11733284 4 48028097 [A/G] NM_207330 NIPAL1 Silent rs10517204 4 48036711 [A/G] NM_207330 NIPAL1 Silent rs13116684 4 48037926 [A/G] NM_207330 NIPAL1 EXON Missense_I324V rs10938519 4 48038584 [A/G] NM_207330 NIPAL1 EXON Silent rs4695329 4 48044017 [T/C] rs4340770 4 48047367 [A/G] rs6812991 4 48047591 [T/C] rs16860898 4 48050604 [A/G] rs17470528 4 48052003 [T/C] rs1507925 4 48060694 [A/G] rs6839501 4 48066864 [T/G] rs1567217 4 48068783 [A/G] NM_003328 TXK EXON Silent rs9996535 4 48069725 [A/G] NM_003328 TXK Silent rs6830656 4 48070855 [A/G] NM_003328 TXK Silent rs906486 4 48073501 [T/G] NM_003328 TXK Silent rs6850108 4 48078593 [A/C] NM_003328 TXK Silent rs12647931 4 48083021 [A/G] NM_003328 TXK Silent rs6858664 4 48088446 [A/G] NM_003328 TXK Silent rs13118073 4 48094275 [T/C] NM_003328 TXK Silent rs6822209 4 48100497 [A/C] NM_003328 TXK Silent rs7658300 4 48115264 [T/C] NM_003328 TXK EXON Missense_R45H rs2704439 4 48126086 [T/C] NM_003328 TXK Silent rs6837324 4 48127262 [A/G] NM_003328 TXK Silent rs885443 4 48132891 [A/G] NM_003328 TXK Silent rs11931912 4 48134118 [A/G] NM_003328 TXK Silent rs3805184 4 48138235 [A/G] NM_003215 TEC EXON Silent rs16861029 4 48138374 [T/C] NM_003215 TEC EXON Silent rs17470892 4 48143201 [T/C] NM_003215 TEC Silent rs996223 4 48146864 [A/G] NM_003215 TEC Silent rs17574371 4 48147309 [T/C] NM_003215 TEC EXON Synonymous_K419K rs2661548 4 48147774 [A/G] NM_003215 TEC Silent rs2704436 4 48161944 [A/G] NM_003215 TEC Silent rs3792622 4 48164537 [A/G] NM_003215 TEC Silent rs16861083 4 48165757 [A/G] NM_003215 TEC EXON Synonymous_Y233Y rs13104849 4 48165834 [T/C] NM_003215 TEC Silent rs2271173 4 48172266 [A/G] NM_003215 TEC EXON Synonymous_S151S rs4312730 4 48182433 [T/C] NM_003215 TEC Silent rs7693779 4 48186152 [A/G] NM_003215 TEC Silent rs4695356 4 48190141 [A/G] NM_003215 TEC Silent rs17655249 4 48191491 [T/C] NM_003215 TEC Silent rs16861108 4 48192185 [A/G] NM_003215 TEC Silent rs17471142 4 48195725 [A/G] NM_003215 TEC Silent rs16861112 4 48195942 [T/C] NM_003215 TEC Silent rs2352593 4 48197767 [A/G] NM_003215 TEC Silent rs6829390 4 48198986 [A/G] NM_003215 TEC Silent rs2704425 4 48199814 [T/C] NM_003215 TEC Silent rs2457415 4 48200584 [A/C] NM_003215 TEC Silent rs2457414 4 48201821 [A/C] NM_003215 TEC Silent rs2017242 4 48204594 [A/C] NM_003215 TEC Silent rs11942525 4 48205942 [T/C] NM_003215 TEC Silent rs1912163 4 48210653 [T/G] NM_003215 TEC Silent rs1509657 4 48213011 [T/C] NM_003215 TEC Silent rs16861128 4 48225077 [A/G] NM_003215 TEC Silent rs4694890 4 48226267 [A/C] NM_003215 TEC Silent rs2704423 4 48227782 [A/G] NM_003215 TEC Silent rs2704421 4 48228266 [T/C] NM_003215 TEC Silent rs2664017 4 48229886 [A/G] NM_003215 TEC Silent rs2664019 4 48230206 [A/G] NM_003215 TEC Silent rs6849860 4 48231311 [A/C] NM_003215 TEC Silent rs6826144 4 48231332 [A/C] NM_003215 TEC Silent rs2704405 4 48234689 [A/G] NM_003215 TEC Silent rs11933797 4 48244736 [A/G] NM_003215 TEC Silent rs12643804 4 48248258 [A/G] NM_003215 TEC Silent rs12507853 4 48252605 [A/G] NM_003215 TEC Silent rs10006371 4 48255215 [A/C] NM_003215 TEC Silent rs2055800 4 48259598 [T/C] NM_003215 TEC Silent rs1472971 4 48260644 [A/G] NM_003215 TEC Silent rs10938526 4 48263941 [T/G] NM_003215 TEC Silent rs6845740 4 48269738 [A/C] NM_003215 TEC Silent rs9994779 4 48269985 [A/G] NM_003215 TEC Silent rs6852406 4 48274152 [A/G] rs6447628 4 48290233 [T/C] rs380016 4 48296382 [T/C] rs309890 4 48302896 [T/C] rs6814786 4 48313005 [A/C] rs4599384 4 48318390 [A/G] rs4695372 4 48332641 [T/C] rs309875 4 48335265 [T/C] rs16861203 4 48335857 [A/G] rs17609346 4 48336371 [T/C] rs309872 4 48336985 [T/G] rs10517217 4 48353342 [A/G] NM_020846 SLAIN2 Silent rs411261 4 48354057 [T/C] NM_020846 SLAIN2 Silent rs409911 4 48354515 [T/G] NM_020846 SLAIN2 Silent rs429969 4 48356333 [A/G] NM_020846 SLAIN2 Silent rs6447631 4 48374652 [T/C] NM_020846 SLAIN2 Silent rs11725992 4 48387851 [T/C] NM_020846 SLAIN2 Silent rs17609521 4 48393721 [A/G] NM_020846 SLAIN2 Silent rs1055721 4 48427773 [A/G] NM_020846 SLAIN2 EXON Silent rs11932126 4 48435595 [T/C] rs6447636 4 48459365 [T/C] rs4695379 4 48462164 [A/G] rs2353315 4 48462902 [A/C] rs7698564 4 48463167 [T/C] rs4695383 4 48465495 [A/C] rs10024547 4 48467710 [A/G] rs745761 4 48473439 [A/G] rs6838613 4 48476539 [A/G] rs1565217 4 48479718 [T/C] rs992423 4 48481976 [T/C] rs6812980 4 48484060 [T/G] rs6836632 4 48485075 [A/G] rs3811759 4 48491010 [A/G] NM_152679 SLC10A4 EXON Silent rs7668401 4 48491442 [T/C] NM_152679 SLC10A4 EXON Silent rs4413478 4 48491651 [A/G] rs9993088 4 48494546 [A/C] NM_175619 ZAR1 Silent rs17609740 4 48494924 [A/G] NM_175619 ZAR1 Silent rs7694862 4 48495615 [T/C] NM_175619 ZAR1 Silent rs10031777 4 48498290 [T/C] rs10029732 4 48498679 [A/G] rs6447641 4 48509050 [T/C] NM_015030 FRYL Silent rs937888 4 48543896 [A/C] NM_015030 FRYL Silent rs17656125 4 48569448 [T/C] NM_015030 FRYL Silent rs10805172 4 48572439 [T/C] NM_015030 FRYL Silent rs17575727 4 48573038 [T/C] NM_015030 FRYL Silent rs4695391 4 48582909 [A/G] NM_015030 FRYL EXON Synonymous_S744S rs3107023 4 48584405 [T/C] NM_015030 FRYL Silent rs16861398 4 48588823 [T/C] NM_015030 FRYL Silent rs1507864 4 48605628 [A/G] NM_015030 FRYL Silent rs776602 4 48611929 [A/C] NM_015030 FRYL Silent rs1876469 4 48627192 [T/C] NM_015030 FRYL Silent rs6845295 4 48662596 [T/G] NM_015030 FRYL Silent rs11931039 4 48695108 [T/C] NM_015030 FRYL Silent rs4695396 4 48708512 [T/C] NM_015030 FRYL Silent rs10938540 4 48726266 [T/C] NM_015030 FRYL Silent rs1554256 4 48764009 [T/C] NM_015030 FRYL Silent rs6447662 4 48782647 [A/C] rs7698064 4 48785035 [A/G] rs7665209 4 48814687 [T/C] rs17576196 4 48817703 [A/G] rs12649401 4 48828657 [A/G] rs17656641 4 48832131 [T/C] rs3761731 4 48832968 [A/G] rs11733534 4 48851540 [T/C] NM_017830,NM_001079841,NM_001079840,NM_001079842,NM_001079839,NM_001168254 OCIAD1,OCIAD1,OCIAD1,OCIAD1,OCIAD1,OCIAD1 Silent,Silent,Silent,Silent,Silent,Silent rs3761729 4 48851937 [T/C] NM_017830,NM_001079841,NM_001079840,NM_001079842,NM_001079839,NM_001168254 OCIAD1,OCIAD1,OCIAD1,OCIAD1,OCIAD1,OCIAD1 Silent,Silent,Silent,Silent,Silent,Silent rs17656727 4 48856133 [A/G] NM_017830,NM_001079841,NM_001079840,NM_001079842,NM_001079839,NM_001168254,NR_146806 OCIAD1,OCIAD1,OCIAD1,OCIAD1,OCIAD1,OCIAD1,OCIAD1-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17610725 4 48864595 [T/C] rs6447666 4 48879374 [A/G] rs2354946 4 48881671 [A/G] rs2354947 4 48886730 [A/C] rs2289065 4 48894981 [A/G] NM_001286774,NM_001014446,NR_104589,NM_152398,NM_001286773 OCIAD2,OCIAD2,OCIAD2,OCIAD2,OCIAD2 Silent,Silent,Silent,Silent,Silent rs2605242 4 48910970 [T/C] rs2572349 4 48912028 [A/G] rs2085292 4 48914936 [A/G] rs724598 4 48915324 [A/C] rs2572340 4 48916215 [A/G] rs2247481 4 48936821 [A/G] rs1455942 4 48940906 [A/G] rs2605262 4 48952209 [A/G] rs2605267 4 48960863 [A/G] rs2572363 4 48972651 [A/C] rs6824559 4 48972943 [T/C] rs3747690 4 48988450 [A/C] NM_025087 CWH43 EXON Missense_P2T rs4695414 4 48989358 [A/G] NM_025087,NM_001286791 CWH43,CWH43 Silent,Silent rs936135 4 48991540 [A/G] NM_025087,NM_001286791 CWH43,CWH43 Silent,Silent rs1350123 4 48999842 [A/G] NM_025087,NM_001286791 CWH43,CWH43 Silent,Silent rs10222924 4 49016761 [A/G] NM_025087,NM_001286791 CWH43,CWH43 Silent,Silent rs11730515 4 49019702 [T/C] NM_025087,NM_001286791 CWH43,CWH43 Silent,Silent rs6822902 4 49021099 [A/G] NM_025087,NM_001286791 CWH43,CWH43 Silent,Silent rs2768957 4 49053522 [A/G] NM_025087,NM_001286791 CWH43,CWH43 Silent,Silent rs7655341 4 49061141 [T/C] NM_025087,NM_001286791 CWH43,CWH43 Silent,Silent rs12696828 4 49061848 [T/C] NM_025087,NM_001286791 CWH43,CWH43 Silent,Silent rs11725957 4 49062892 [A/G] NM_025087,NM_001286791 CWH43,CWH43 Silent,Silent rs1051447 4 49063872 [A/C] NM_025087,NM_001286791 CWH43,CWH43 EXON Missense_H689N,Missense_H662N rs13114564 4 49067067 [A/C] rs7674086 4 49091782 [T/C] rs4695446 4 49102156 [A/G] rs6830316 4 49109992 [T/C] rs12163878 4 49513783 [T/G] rs4975396 4 49552325 [A/C] rs9631924 4 49553810 [A/G] rs7688829 4 49617483 [A/C] rs12163792 4 49620898 [T/G] rs2134981 4 52697856 [T/C] rs10012987 4 52706270 [A/G] rs6848075 4 52706713 [T/A] rs7440594 4 52708882 [T/C] rs10018242 4 52713195 [A/G] NM_015115,NM_001287757,NM_001040402,NM_001287755 DCUN1D4,DCUN1D4,DCUN1D4,DCUN1D4 Silent,Silent,Silent,Silent rs4865284 4 52720761 [T/C] NM_015115,NM_001287757,NM_001040402,NM_001287755 DCUN1D4,DCUN1D4,DCUN1D4,DCUN1D4 Silent,Silent,Silent,Silent rs6856974 4 52728324 [T/G] NM_015115,NM_001287757,NM_001040402,NM_001287755 DCUN1D4,DCUN1D4,DCUN1D4,DCUN1D4 Silent,Silent,Silent,Silent rs6829208 4 52728640 [T/C] NM_015115,NM_001287757,NM_001040402,NM_001287755 DCUN1D4,DCUN1D4,DCUN1D4,DCUN1D4 Silent,Silent,Silent,Silent rs10012938 4 52745959 [T/C] NM_015115,NM_001287757,NM_001040402,NM_001287755 DCUN1D4,DCUN1D4,DCUN1D4,DCUN1D4 Silent,Silent,Silent,Silent rs17473626 4 52778163 [T/C] NM_015115,NM_001287757,NM_001040402,NM_001287755 DCUN1D4,DCUN1D4,DCUN1D4,DCUN1D4 Silent,Silent,Silent,Silent rs6852236 4 52784678 [A/G] rs17473696 4 52787972 [T/C] rs1996617 4 52798624 [T/C] rs1401718 4 52801096 [T/C] rs6829655 4 52810307 [T/C] rs11735705 4 52830444 [T/G] rs12648674 4 52858627 [A/G] rs1519588 4 52860156 [T/C] NM_001024611 LRRC66 EXON Silent rs17611784 4 52864476 [T/C] NM_001024611 LRRC66 Silent rs7695726 4 52867437 [A/C] NM_001024611 LRRC66 Silent rs4610396 4 52871894 [T/G] NM_001024611 LRRC66 Silent rs2030333 4 52872238 [T/C] NM_001024611 LRRC66 Silent rs17083554 4 52881759 [A/G] NM_001024611 LRRC66 Silent rs225160 4 52884239 [A/G] rs170424 4 52888026 [A/C] NM_000232 SGCB EXON Silent rs225163 4 52888499 [A/G] NM_000232 SGCB EXON Silent rs13989 4 52888557 [A/G] NM_000232 SGCB EXON Silent rs2125980 4 52891292 [T/C] NM_000232 SGCB Silent rs13115541 4 52902709 [A/G] NM_000232 SGCB Silent rs10434429 4 52904614 [A/C] rs12502690 4 52914234 [A/C] rs12507167 4 52918703 [T/C] NM_001297608,NR_144359,NM_145263,NM_001346103,NM_001346102,NR_123728 SPATA18,SPATA18,SPATA18,SPATA18,SPATA18,SPATA18 Silent,Silent,Silent,Silent,Silent,Silent rs784943 4 52923205 [T/C] NM_001297608,NR_144359,NM_145263,NM_001346103,NM_001346102,NR_123728 SPATA18,SPATA18,SPATA18,SPATA18,SPATA18,SPATA18 Silent,Silent,Silent,Silent,Silent,Silent rs1380853 4 52924436 [T/G] NM_001297608,NR_144359,NM_145263,NM_001346103,NM_001346102,NR_123728 SPATA18,SPATA18,SPATA18,SPATA18,SPATA18,SPATA18 Silent,Silent,Silent,Silent,Silent,Silent rs13147207 4 52924778 [A/G] NM_001297608,NR_144359,NM_145263,NM_001346103,NM_001346102,NR_123728 SPATA18,SPATA18,SPATA18,SPATA18,SPATA18,SPATA18 Silent,Silent,Silent,Silent,Silent,Silent rs3860707 4 52938243 [T/C] NM_001297608,NR_144359,NM_145263,NM_001346103,NM_001346102,NR_123728 SPATA18,SPATA18,SPATA18,SPATA18,SPATA18,SPATA18 EXON Missense_S195P,Silent,Missense_S227P,Missense_S2P,Missense_S90P,Silent rs7657148 4 52946161 [A/G] NM_001297608,NR_144359,NM_145263,NM_001346103,NM_001346102,NR_123728 SPATA18,SPATA18,SPATA18,SPATA18,SPATA18,SPATA18 Silent,Silent,Silent,Silent,Silent,Silent rs11727580 4 52948118 [A/G] NM_001297608,NR_144359,NM_145263,NM_001346103,NM_001346102,NR_123728 SPATA18,SPATA18,SPATA18,SPATA18,SPATA18,SPATA18 Silent,Silent,Silent,Silent,Silent,Silent rs17081804 4 52952193 [A/G] NM_001297608,NR_144359,NM_145263,NM_001346103,NM_001346102,NR_123728 SPATA18,SPATA18,SPATA18,SPATA18,SPATA18,SPATA18 Silent,Silent,Silent,Silent,Silent,Silent rs17084573 4 52961938 [A/G] NM_001297608,NR_144359,NM_145263,NM_001346103,NM_001346102,NR_123728 SPATA18,SPATA18,SPATA18,SPATA18,SPATA18,SPATA18 EXON Silent,Silent,Silent,Silent,Silent,Silent rs10011990 4 52962529 [T/C] NM_001297608,NR_144359,NM_145263,NM_001346103,NM_001346102,NR_123728 SPATA18,SPATA18,SPATA18,SPATA18,SPATA18,SPATA18 EXON Silent,Silent,Silent,Silent,Silent,Silent rs13122418 4 52968477 [A/G] rs11722603 4 52969732 [A/G] rs7692196 4 52972702 [A/G] rs7678370 4 52976937 [T/C] rs1460560 4 52977024 [A/G] rs12500525 4 53015654 [A/G] rs6838515 4 53017311 [A/G] rs10517246 4 53038557 [T/C] rs13152091 4 53047572 [T/C] rs13353646 4 53061395 [T/C] rs11133414 4 53069867 [A/G] rs9685444 4 53070929 [A/G] rs17842688 4 53071767 [T/C] rs10025784 4 53102601 [T/C] rs4470701 4 53103892 [T/C] rs1871870 4 53108038 [T/C] rs1482111 4 53122296 [A/G] rs11731574 4 53122932 [T/C] rs995239 4 53130243 [A/C] rs6554360 4 53136123 [T/C] rs1384152 4 53154469 [A/G] rs4590104 4 53154570 [T/C] rs13127514 4 53155184 [A/G] rs967736 4 53169541 [A/G] rs349373 4 53176247 [A/G] rs17675093 4 53179320 [T/C] rs28819715 4 53193560 [A/G] rs7662388 4 53222633 [T/C] rs959214 4 53233385 [A/G] rs1459814 4 53239603 [A/G] rs730284 4 53243713 [T/C] rs7692441 4 53270011 [T/C] rs7685146 4 53272234 [A/G] rs6834296 4 53283093 [T/C] rs11133542 4 53288276 [A/G] rs931734 4 53296310 [A/G] rs11732165 4 53325022 [A/G] rs9312700 4 53336721 [A/G] rs1459822 4 53339047 [A/G] rs346901 4 53383129 [A/G] rs1347763 4 53399616 [T/C] rs9312711 4 53402146 [A/G] rs10034992 4 53414666 [A/G] rs13435749 4 53433480 [A/G] rs346011 4 53434611 [A/G] rs1948709 4 53450096 [T/C] rs17051578 4 53453449 [T/C] rs346005 4 53454738 [A/C] rs7668895 4 53456416 [A/C] rs3733506 4 53459620 [A/G] NM_001286768,NM_022832,NM_001286767,NM_001134223 USP46,USP46,USP46,USP46 EXON Silent,Silent,Silent,Silent rs17051586 4 53463566 [T/C] NM_001286768,NM_022832,NM_001286767,NM_001134223 USP46,USP46,USP46,USP46 EXON Silent,Silent,Silent,Silent rs10010306 4 53463803 [A/C] NM_001286768,NM_022832,NM_001286767,NM_001134223 USP46,USP46,USP46,USP46 EXON Silent,Silent,Silent,Silent rs2244291 4 53468479 [T/C] NM_001286768,NM_022832,NM_001286767,NM_001134223 USP46,USP46,USP46,USP46 Silent,Silent,Silent,Silent rs7680727 4 53472171 [A/G] NM_001286768,NM_022832,NM_001286767,NM_001134223 USP46,USP46,USP46,USP46 Silent,Silent,Silent,Silent rs17051645 4 53512676 [T/C] NM_001286768,NM_022832,NM_001286767,NM_001134223 USP46,USP46,USP46,USP46 Silent,Silent,Silent,Silent rs10014556 4 53523725 [A/G] NM_001286768,NM_022832,NM_001286767 USP46,USP46,USP46 Silent,Silent,Silent rs10517266 4 53549643 [T/C] rs6830833 4 53565358 [T/C] rs10028122 4 53578009 [A/G] rs7677282 4 53582065 [A/G] NR_145129,NR_145130 DANCR,DANCR Silent,Silent rs6840875 4 53604587 [T/C] rs4865408 4 53619367 [T/C] rs10000105 4 53623677 [A/G] rs10009096 4 53623737 [T/C] rs6838531 4 53627606 [A/C] rs4865412 4 53629126 [A/C] rs2411265 4 53643479 [A/G] rs10000595 4 53646007 [A/C] rs17476009 4 53647521 [T/C] rs1384847 4 53675834 [A/G] NR_040106 LINC01618 Silent rs730247 4 53680696 [T/G] NR_040106 LINC01618 Silent rs4864676 4 53681594 [T/C] NR_040106 LINC01618 EXON Silent rs7658762 4 53688988 [T/C] rs10008073 4 53692040 [T/C] rs7667301 4 53700565 [T/C] rs6838718 4 53710828 [T/C] rs17698672 4 53711634 [T/C] rs9993034 4 53712071 [T/C] rs7662817 4 53712304 [A/G] rs10026162 4 53718375 [A/G] rs6818178 4 53724744 [A/G] rs881743 4 53727450 [A/G] rs881744 4 53727487 [T/C] rs2279334 4 53732445 [T/C] NM_023940 RASL11B EXON Silent rs8287 4 53732586 [T/C] NM_023940 RASL11B EXON Silent rs1043975 4 53732611 [T/G] NM_023940 RASL11B EXON Silent rs7699960 4 53735661 [A/C] rs6835977 4 53739672 [T/G] NM_152540 SCFD2 EXON Silent rs6852148 4 53750002 [T/C] NM_152540 SCFD2 Silent rs2306600 4 53751932 [T/C] NM_152540 SCFD2 EXON Synonymous_S648S rs2898681 4 53757000 [A/G] NM_152540 SCFD2 Silent rs17643154 4 53769355 [A/G] NM_152540 SCFD2 Silent rs2930103 4 53773371 [A/C] NM_152540 SCFD2 Silent rs10866413 4 53774933 [A/G] NM_152540 SCFD2 Silent rs10014061 4 53776206 [A/G] NM_152540 SCFD2 Silent rs301126 4 53795651 [T/C] NM_152540 SCFD2 Silent rs301119 4 53798146 [A/C] NM_152540 SCFD2 Silent rs301113 4 53801092 [T/G] NM_152540 SCFD2 Silent rs13104971 4 53820155 [A/G] NM_152540 SCFD2 Silent rs301092 4 53821849 [T/C] NM_152540 SCFD2 Silent rs17644026 4 53828606 [T/C] NM_152540 SCFD2 Silent rs17082225 4 53828649 [A/G] NM_152540 SCFD2 Silent rs301088 4 53830757 [A/C] NM_152540 SCFD2 Silent rs2101201 4 53842714 [T/C] NM_152540 SCFD2 Silent rs2411289 4 53844275 [A/C] NM_152540 SCFD2 Silent rs13120717 4 53846584 [T/C] NM_152540 SCFD2 Silent rs11133239 4 53848506 [T/C] NM_152540 SCFD2 Silent rs1531836 4 53850860 [A/G] NM_152540 SCFD2 Silent rs6849838 4 53859627 [A/G] NM_152540 SCFD2 Silent rs3860706 4 53859826 [A/G] NM_152540 SCFD2 Silent rs6838924 4 53863777 [T/C] NM_152540 SCFD2 Silent rs11929934 4 53867132 [A/G] NM_152540 SCFD2 Silent rs11133240 4 53869083 [T/C] NM_152540 SCFD2 Silent rs12641446 4 53871388 [A/G] NM_152540 SCFD2 Silent rs17701605 4 53872674 [A/G] NM_152540 SCFD2 Silent rs4864709 4 53879085 [T/C] NM_152540 SCFD2 Silent rs10012324 4 53879152 [A/G] NM_152540 SCFD2 Silent rs2411288 4 53880619 [A/G] NM_152540 SCFD2 Silent rs10024057 4 53888072 [T/C] NM_152540 SCFD2 Silent rs17082288 4 53891706 [T/G] NM_152540 SCFD2 Silent rs17082301 4 53893156 [A/G] NM_152540 SCFD2 Silent rs4864715 4 53907444 [T/G] NM_152540 SCFD2 Silent rs13143381 4 53910138 [A/G] NM_152540 SCFD2 Silent rs10517278 4 53915624 [A/G] NM_152540 SCFD2 Silent rs2046306 4 53922626 [A/C] NM_152540 SCFD2 Silent rs2411290 4 53939510 [T/C] NM_152540 SCFD2 Silent rs1038356 4 53939819 [A/G] NM_152540 SCFD2 Silent rs13141532 4 53959141 [T/C] NM_152540 SCFD2 Silent rs11934112 4 53960196 [T/C] NM_152540 SCFD2 Silent rs7661029 4 53965247 [A/G] NM_152540 SCFD2 Silent rs4864446 4 53980677 [A/C] NM_152540 SCFD2 Silent rs7683505 4 53982975 [A/G] NM_152540 SCFD2 Silent rs4864723 4 53986846 [T/C] NM_152540 SCFD2 Silent rs10517279 4 53990594 [T/C] NM_152540 SCFD2 Silent rs10016091 4 53991510 [A/G] NM_152540 SCFD2 Silent rs10028181 4 54000949 [A/G] NM_152540 SCFD2 Silent rs10033590 4 54001960 [T/C] NM_152540 SCFD2 Silent rs7696426 4 54008839 [T/C] NM_152540 SCFD2 Silent rs4864727 4 54011424 [T/C] NM_152540 SCFD2 Silent rs7675987 4 54011526 [A/G] NM_152540 SCFD2 EXON Missense_L512S rs17082453 4 54011603 [T/C] NM_152540 SCFD2 EXON Synonymous_T486T rs7693228 4 54013155 [T/C] NM_152540 SCFD2 Silent rs6818457 4 54016241 [A/C] NM_152540 SCFD2 Silent rs4864728 4 54017971 [A/C] NM_152540 SCFD2 Silent rs1962230 4 54021591 [A/G] NM_152540 SCFD2 Silent rs7694213 4 54023351 [A/G] NM_152540 SCFD2 Silent rs9312637 4 54026736 [T/C] NM_152540 SCFD2 Silent rs10517281 4 54027595 [A/G] NM_152540 SCFD2 Silent rs17082492 4 54033543 [T/C] NM_152540 SCFD2 Silent rs13111251 4 54043211 [A/G] NM_152540 SCFD2 Silent rs11133248 4 54058102 [A/G] NM_152540 SCFD2 Silent rs12507517 4 54061989 [T/C] NM_152540 SCFD2 Silent rs4588514 4 54074642 [A/G] NM_152540 SCFD2 Silent rs12108246 4 54078164 [T/C] NM_152540 SCFD2 Silent rs6818181 4 54087096 [A/G] NM_152540 SCFD2 Silent rs11939189 4 54089331 [T/C] NM_152540 SCFD2 Silent rs4472196 4 54107382 [A/G] NM_152540 SCFD2 Silent rs17082557 4 54140416 [T/G] NM_152540 SCFD2 Silent rs9884671 4 54147428 [A/G] NM_152540 SCFD2 Silent rs17082563 4 54172210 [T/G] NM_152540 SCFD2 Silent rs4864747 4 54181789 [T/C] NM_152540 SCFD2 Silent rs12512496 4 54181814 [T/C] NM_152540 SCFD2 Silent rs11725172 4 54203701 [T/G] NM_152540 SCFD2 Silent rs10002674 4 54213099 [A/G] NM_152540 SCFD2 Silent rs10517292 4 54214528 [T/C] NM_152540 SCFD2 Silent rs1600795 4 54221952 [T/G] NM_152540 SCFD2 Silent rs2128103 4 54222481 [A/C] NM_152540 SCFD2 Silent rs1351514 4 54232110 [A/G] NM_152540 SCFD2 EXON Silent rs6554097 4 54232644 [T/C] rs6554098 4 54232658 [A/G] rs6828559 4 54235363 [T/G] rs1481823 4 54238009 [A/G] rs11133267 4 54243425 [T/C] rs10517295 4 54252882 [T/C] NM_001134938,NM_030917,NM_001134937 FIP1L1,FIP1L1,FIP1L1 Silent,Silent,Silent rs1481819 4 54254146 [A/G] NM_001134938,NM_030917,NM_001134937 FIP1L1,FIP1L1,FIP1L1 Silent,Silent,Silent rs10025091 4 54264543 [T/C] NM_001134938,NM_030917,NM_001134937 FIP1L1,FIP1L1,FIP1L1 Silent,Silent,Silent rs11133274 4 54299380 [T/C] NM_001134938,NM_030917,NM_001134937 FIP1L1,FIP1L1,FIP1L1 Silent,Silent,Silent rs17326196 4 54314418 [T/C] NM_001134938,NM_030917,NM_001134937 FIP1L1,FIP1L1,FIP1L1 Silent,Silent,Silent rs13142904 4 54318414 [T/C] NM_001134938,NM_030917,NM_001134937 FIP1L1,FIP1L1,FIP1L1 Silent,Silent,Silent rs2412487 4 54324379 [A/G] NM_001134938,NM_030917,NM_001134937 FIP1L1,FIP1L1,FIP1L1 Silent,Silent,Silent rs15887 4 54325516 [A/G] NM_001134938,NM_030917,NM_001134937 FIP1L1,FIP1L1,FIP1L1 EXON Missense_R488K,Missense_R562K,Missense_R556K rs1014056 4 54325990 [T/C] NM_001134938,NM_030917,NM_001134937 FIP1L1,FIP1L1,FIP1L1 EXON Silent,Silent,Silent rs12505040 4 54339478 [T/C] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs4864763 4 54341346 [A/G] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs6835629 4 54346483 [T/C] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs6838260 4 54355824 [A/G] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs12642403 4 54361640 [T/C] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs6836800 4 54362150 [A/G] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs4864767 4 54367136 [A/G] NM_001126328,NM_032622,NR_046622 LNX1,LNX1,LNX1-AS1 Silent,Silent,Silent rs10021772 4 54373464 [T/C] NM_001126328,NM_032622,NR_046622 LNX1,LNX1,LNX1-AS1 Silent,Silent,Silent rs2164265 4 54377540 [A/G] NM_001126328,NM_032622,NR_046622 LNX1,LNX1,LNX1-AS1 Silent,Silent,Silent rs11935144 4 54377597 [T/C] NM_001126328,NM_032622,NR_046622 LNX1,LNX1,LNX1-AS1 Silent,Silent,Silent rs2117598 4 54377975 [A/C] NM_001126328,NM_032622,NR_046622 LNX1,LNX1,LNX1-AS1 Silent,Silent,Silent rs4864463 4 54378854 [T/C] NM_001126328,NM_032622,NR_046622 LNX1,LNX1,LNX1-AS1 Silent,Silent,Silent rs11723567 4 54380052 [T/C] NM_001126328,NM_032622,NR_046622 LNX1,LNX1,LNX1-AS1 Silent,Silent,Silent rs9999406 4 54381345 [T/C] NM_001126328,NM_032622,NR_046622 LNX1,LNX1,LNX1-AS1 Silent,Silent,Silent rs1541967 4 54382119 [T/G] NM_001126328,NM_032622,NR_046622 LNX1,LNX1,LNX1-AS1 Silent,Silent,Silent rs4864777 4 54382225 [A/G] NM_001126328,NM_032622,NR_046622 LNX1,LNX1,LNX1-AS1 Silent,Silent,Silent rs17082951 4 54393115 [A/G] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs17082953 4 54394093 [T/C] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs4864785 4 54394410 [T/C] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs10517300 4 54395740 [T/C] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs6812114 4 54396077 [T/C] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs1435221 4 54398776 [A/G] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs1435219 4 54401849 [A/G] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs17082977 4 54403898 [T/C] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs12331079 4 54409561 [A/C] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs1040084 4 54410224 [A/G] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs1913484 4 54410324 [A/G] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs17660061 4 54410671 [T/C] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs1435215 4 54411534 [A/G] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs7697542 4 54413069 [T/C] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs6820391 4 54414696 [A/C] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs6815418 4 54416496 [T/C] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs2117600 4 54417674 [A/G] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs6554112 4 54418635 [A/G] NM_001126328,NM_032622 LNX1,LNX1 Silent,Silent rs4864795 4 54425184 [T/C] NM_001126328 LNX1 Silent rs6850277 4 54427925 [A/G] NM_001126328 LNX1 Silent rs4864800 4 54439033 [A/G] NM_001126328 LNX1 Silent rs4864801 4 54442182 [T/C] NM_001126328 LNX1 Silent rs1369355 4 54446860 [A/G] NM_001126328 LNX1 Silent rs932039 4 54451175 [T/C] NM_001126328 LNX1 Silent rs932038 4 54451246 [T/C] NM_001126328 LNX1 Silent rs1347406 4 54452487 [A/G] NM_001126328 LNX1 Silent rs979006 4 54452878 [A/G] NM_001126328 LNX1 Silent rs11731437 4 54453084 [T/C] NM_001126328 LNX1 Silent rs17083112 4 54453676 [T/C] NM_001126328 LNX1 Silent rs9312642 4 54456051 [A/G] NM_001126328 LNX1 Silent rs1028000 4 54460531 [T/C] NR_046827 LNX1-AS2 Silent rs1464028 4 54460824 [A/C] NR_046827 LNX1-AS2 Silent rs1015801 4 54461548 [T/C] NR_046827 LNX1-AS2 Silent rs1369351 4 54462952 [T/C] NR_046827 LNX1-AS2 Silent rs7668052 4 54463384 [T/C] NR_046827 LNX1-AS2 Silent rs2668568 4 54471672 [A/G] rs2616404 4 54474244 [A/G] rs959094 4 54483569 [A/G] rs2616417 4 54488165 [A/G] rs10031866 4 54489838 [T/G] rs2572297 4 54490116 [A/G] rs2572290 4 54493031 [T/C] rs2572291 4 54493383 [A/G] rs1546526 4 54499251 [T/C] rs2668524 4 54505850 [T/C] rs4864809 4 54511913 [A/G] rs1077966 4 54517341 [T/C] rs17083248 4 54517724 [T/C] rs17083255 4 54524939 [T/C] rs2590809 4 54542666 [A/G] rs1351054 4 54543242 [T/C] rs2199574 4 54547031 [T/G] rs2199572 4 54547406 [T/G] rs2668532 4 54556087 [T/C] rs991670 4 54558299 [T/C] rs2590783 4 54559738 [T/C] rs6827185 4 54561980 [A/G] rs1871029 4 54564016 [A/G] NR_125918 LOC100506444 Silent rs715155 4 54572307 [T/C] NR_125918 LOC100506444 Silent rs2668540 4 54574146 [A/C] NR_125918 LOC100506444 Silent rs728587 4 54574680 [A/G] NR_125918 LOC100506444 Silent rs2590784 4 54575432 [T/C] NR_125918 LOC100506444 Silent rs9684467 4 54582132 [A/G] NR_125918 LOC100506444 Silent rs2590828 4 54589655 [T/C] NR_125918 LOC100506444 Silent rs10517293 4 54589815 [A/G] NR_125918 LOC100506444 Silent rs2245157 4 54596466 [T/G] NR_125918 LOC100506444 Silent rs2616411 4 54596896 [A/G] NR_125918 LOC100506444 Silent rs1382084 4 54598787 [T/C] NR_125918 LOC100506444 Silent rs3844504 4 54608737 [A/C] rs4082297 4 54608763 [T/C] rs3853200 4 54609243 [T/C] rs7664385 4 54612049 [A/G] rs2590765 4 54615216 [A/G] rs2616434 4 54616649 [A/G] rs2590767 4 54618574 [T/C] rs6852807 4 54621715 [A/G] rs11942282 4 54624264 [T/G] rs4530695 4 54629640 [T/C] rs6842213 4 54632173 [A/G] rs2412494 4 54633159 [T/C] rs6823803 4 54633774 [A/G] rs4305579 4 54638662 [A/C] rs2412493 4 54638699 [A/G] rs11726943 4 54639903 [A/G] rs4501282 4 54650286 [A/C] rs2088582 4 54653803 [T/C] rs6811489 4 54656460 [T/G] rs6844333 4 54657093 [T/C] rs2412501 4 54661158 [A/G] rs1498821 4 54666951 [T/G] rs994965 4 54676030 [T/C] rs11133290 4 54678796 [A/G] rs4864829 4 54681059 [T/C] rs13108970 4 54698028 [T/C] rs13125746 4 54701833 [A/G] rs17083558 4 54706281 [A/G] rs11133292 4 54707699 [A/G] rs11730478 4 54711138 [A/G] rs6852162 4 54713554 [A/G] rs17083590 4 54714868 [A/G] rs17083601 4 54718275 [A/G] rs7662508 4 54723742 [T/C] rs13106140 4 54724066 [A/G] rs12500026 4 54728147 [A/C] rs1391758 4 54734511 [T/C] rs1498828 4 54736988 [A/G] rs6554139 4 54738622 [T/C] rs2898990 4 54739506 [T/C] rs4558921 4 54740384 [T/C] rs965126 4 54741949 [T/G] rs7659192 4 54750921 [A/G] rs1498827 4 54756219 [T/C] rs13133779 4 54757388 [A/G] rs13135139 4 54757995 [A/G] rs2102012 4 54761404 [T/G] rs1498820 4 54762082 [A/C] rs11133294 4 54770332 [A/G] rs10866415 4 54775225 [A/C] rs1109789 4 54782044 [T/C] rs1357133 4 54784205 [A/G] rs11723268 4 54786223 [A/G] rs11946709 4 54791781 [T/C] rs6811240 4 54793060 [T/C] rs11725926 4 54796220 [T/C] rs17083718 4 54801549 [A/G] rs11133301 4 54801934 [A/C] rs11737196 4 54802080 [T/C] rs17083731 4 54802898 [T/C] rs17083734 4 54804163 [T/C] rs13133473 4 54814760 [T/C] rs7686432 4 54819631 [T/C] rs11133302 4 54825255 [T/C] rs13152774 4 54829996 [T/C] rs6828100 4 54847381 [A/G] rs13105833 4 54850662 [T/C] rs13146026 4 54852070 [T/G] NR_027153 RPL21P44 EXON Silent rs13134590 4 54854377 [A/C] rs13145700 4 54901801 [T/C] NM_012110 CHIC2 Silent rs9990570 4 54902868 [T/C] NM_012110 CHIC2 Silent rs2049170 4 54914865 [T/C] NM_012110 CHIC2 Silent rs13120133 4 54917484 [T/C] NM_012110 CHIC2 Silent rs13121173 4 54917937 [T/C] NM_012110 CHIC2 Silent rs10002384 4 54927037 [T/G] NM_012110 CHIC2 Silent rs2412522 4 54938543 [A/G] rs13117345 4 54943432 [A/G] rs714860 4 54954323 [A/G] rs2412535 4 54956686 [T/C] rs6554147 4 54958646 [T/G] rs35638196 4 54966104 [A/G] rs6554148 4 54967214 [T/C] NM_133267 GSX2 Silent rs2278142 4 54967709 [A/C] NM_133267 GSX2 Silent rs11133304 4 54970684 [T/C] rs6554150 4 54973200 [T/C] rs4864841 4 54986885 [T/C] rs6850083 4 54986912 [T/C] rs1017280 4 55011123 [T/C] rs6554152 4 55016097 [T/C] rs6840522 4 55030375 [A/G] rs10027676 4 55045716 [T/C] rs7659596 4 55049751 [A/G] rs2162136 4 55061398 [T/G] rs12233727 4 55073270 [T/C] rs1559715 4 55073673 [A/G] rs17084040 4 55074368 [A/G] rs6832597 4 55076237 [A/C] rs11133313 4 55081757 [T/C] rs17084051 4 55087581 [A/C] rs2114039 4 55092626 [T/C] rs6554162 4 55093955 [A/G] rs7678144 4 55102425 [T/C] NM_001347827,NM_001347828,NM_006206,NM_001347829,NM_001347830 PDGFRA,PDGFRA,PDGFRA,PDGFRA,PDGFRA Silent,Silent,Silent,Silent,Silent rs7677751 4 55124460 [T/C] NM_001347827,NM_001347828,NM_006206,NM_001347829,NM_001347830 PDGFRA,PDGFRA,PDGFRA,PDGFRA,PDGFRA Silent,Silent,Silent,Silent,Silent rs2307049 4 55130154 [A/G] NM_001347827,NM_001347828,NM_006206,NM_001347829,NM_001347830 PDGFRA,PDGFRA,PDGFRA,PDGFRA,PDGFRA Silent,Silent,Silent,Silent,Silent rs4358459 4 55133726 [T/G] NM_001347827,NM_001347828,NM_006206,NM_001347829,NM_001347830 PDGFRA,PDGFRA,PDGFRA,PDGFRA,PDGFRA EXON Synonymous_G313G,Synonymous_G338G,Synonymous_G313G,Synonymous_G313G,Synonymous_G326G rs7656613 4 55141843 [T/C] NM_001347827,NM_001347828,NM_006206,NM_001347829,NM_001347830 PDGFRA,PDGFRA,PDGFRA,PDGFRA,PDGFRA Silent,Silent,Silent,Silent,Silent rs1547904 4 55146389 [T/C] NM_001347827,NM_001347828,NM_006206,NM_001347829,NM_001347830 PDGFRA,PDGFRA,PDGFRA,PDGFRA,PDGFRA Silent,Silent,Silent,Silent,Silent rs2412559 4 55151711 [A/C] NM_001347828,NM_006206,NM_001347829,NM_001347830 PDGFRA,PDGFRA,PDGFRA,PDGFRA Silent,Silent,Silent,Silent rs2228230 4 55152040 [T/C] NM_001347828,NM_006206,NM_001347829,NM_001347830 PDGFRA,PDGFRA,PDGFRA,PDGFRA EXON Synonymous_V849V,Synonymous_V824V,Synonymous_V824V,Synonymous_V837V rs3733540 4 55161254 [T/C] NM_001347828,NM_006206,NM_001347829,NM_001347830 PDGFRA,PDGFRA,PDGFRA,PDGFRA Silent,Silent,Silent,Silent rs12511976 4 55162271 [T/C] NM_001347828,NM_006206,NM_001347829,NM_001347830 PDGFRA,PDGFRA,PDGFRA,PDGFRA EXON Silent,Silent,Silent,Silent rs17739921 4 55164866 [A/C] rs4583821 4 55193347 [T/C] rs17084148 4 55196620 [T/C] rs17084149 4 55197216 [T/C] rs11729535 4 55198205 [A/G] rs11736538 4 55202124 [T/C] NR_147160 LINC02283 Silent rs17084178 4 55202157 [T/G] NR_147160 LINC02283 Silent rs1389002 4 55220355 [A/G] NR_147160 LINC02283 Silent rs1492767 4 55221467 [T/C] NR_147160 LINC02283 Silent rs2412563 4 55225121 [A/G] rs1444043 4 55233465 [T/C] rs2412564 4 55239947 [A/G] rs17747127 4 55241063 [T/C] rs11939998 4 55242385 [T/C] rs1004564 4 55242625 [A/C] rs2166021 4 55242960 [T/G] rs4572929 4 55245741 [A/G] rs1353005 4 55245897 [T/G] rs1562058 4 55251785 [A/C] rs17691182 4 55251828 [T/C] rs11133321 4 55256927 [A/G] rs1492769 4 55257611 [A/C] rs1156181 4 55259352 [T/C] rs17691810 4 55270873 [T/G] rs11721618 4 55286861 [T/G] rs10517332 4 55288019 [A/G] rs1396066 4 55289826 [A/G] rs1553660 4 55291724 [T/G] rs13129356 4 55295481 [A/G] rs10517334 4 55301708 [T/C] rs17749557 4 55311965 [T/C] rs1507966 4 55314638 [T/G] rs1507959 4 55341076 [A/G] rs6857523 4 55342137 [A/G] rs4864896 4 55344232 [T/C] rs17693577 4 55345209 [T/C] rs12509670 4 55351107 [T/C] rs1507955 4 55354275 [A/G] rs7676607 4 55357990 [T/C] rs13151127 4 55358779 [A/G] rs1507952 4 55361102 [A/G] rs6838519 4 55368702 [T/C] rs6554190 4 55371241 [A/G] rs6554191 4 55374968 [A/C] rs11133333 4 55380471 [T/G] rs17084420 4 55385637 [A/G] rs170118 4 55390494 [A/C] rs10050226 4 55392598 [T/C] rs4864905 4 55393419 [T/C] rs218237 4 55394172 [T/C] rs6824783 4 55402962 [A/G] rs218268 4 55411087 [A/G] rs218273 4 55415172 [T/G] rs9995760 4 55418179 [A/G] rs2110152 4 55418294 [T/C] rs218280 4 55424289 [T/G] rs2537872 4 55426561 [T/C] rs2703489 4 55426618 [A/C] rs13135067 4 55426911 [A/G] rs7657643 4 55430051 [A/G] rs218231 4 55430953 [T/G] rs2703487 4 55434828 [T/C] rs17084481 4 55435875 [T/G] rs2703481 4 55439893 [T/G] rs17084491 4 55446565 [C/G] rs17826456 4 55448581 [T/G] rs4864910 4 55449616 [A/G] rs10488850 4 55457545 [T/C] rs2703476 4 55471848 [A/G] NR_134657 LINC02260 Silent rs2703480 4 55475409 [T/G] rs17827110 4 55477883 [A/G] rs2537883 4 55478047 [T/C] rs17827152 4 55478686 [A/G] rs17230634 4 55480024 [T/C] rs1558500 4 55482077 [A/G] rs2703457 4 55484356 [T/C] rs12512899 4 55486791 [T/G] rs17084534 4 55490810 [T/C] rs759082 4 55491904 [T/G] rs7655814 4 55492212 [A/C] rs17084564 4 55498400 [A/G] rs6554194 4 55499810 [T/G] rs6831020 4 55500226 [A/C] rs2537864 4 55511017 [T/C] rs7695300 4 55512066 [T/C] rs6825657 4 55515359 [A/G] rs4241987 4 55517005 [T/G] rs13147869 4 55519748 [A/G] rs6554198 4 55522160 [A/G] rs2237035 4 55526251 [T/G] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs2237034 4 55528653 [T/G] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs2237032 4 55531875 [T/C] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs2237028 4 55536375 [T/G] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs6820303 4 55541408 [A/G] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs10488845 4 55542869 [A/G] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs13135792 4 55552330 [T/C] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs11946333 4 55553801 [T/C] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs2855777 4 55554155 [A/G] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs2237023 4 55557984 [A/G] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs17084644 4 55565445 [A/G] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs3020825 4 55569146 [T/C] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs3020826 4 55574182 [T/C] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs2237018 4 55575144 [A/G] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs2298976 4 55588536 [A/G] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs11735550 4 55588719 [A/C] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs4864920 4 55590621 [T/G] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs3822214 4 55593464 [A/C] NM_000222,NM_001093772 KIT,KIT EXON Missense_M541L,Missense_M537L rs17084713 4 55597458 [A/G] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs2237012 4 55599998 [A/G] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs2213180 4 55601327 [T/G] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs17084730 4 55601449 [A/C] NM_000222,NM_001093772 KIT,KIT Silent,Silent rs17084733 4 55604940 [A/G] NM_000222,NM_001093772 KIT,KIT EXON Silent,Silent rs8022 4 55606427 [T/G] NM_000222,NM_001093772 KIT,KIT EXON Silent,Silent rs17084754 4 55610192 [T/C] rs4406072 4 55610660 [T/G] rs4355454 4 55610848 [A/G] rs4864522 4 55617208 [A/G] rs10213491 4 55624059 [A/G] rs3109915 4 55639547 [A/G] rs11732323 4 55643116 [A/G] rs7686567 4 55650767 [A/G] rs2173229 4 55656500 [A/G] rs2646336 4 55658124 [A/G] rs2646325 4 55668740 [A/G] rs1982975 4 55669590 [T/G] rs6821963 4 55673133 [A/G] rs4864926 4 55680855 [T/C] rs6821967 4 55682619 [A/G] rs2412611 4 55683735 [T/G] rs904140 4 55683815 [T/C] rs2726646 4 55683987 [A/C] rs2646356 4 55684426 [T/C] rs17084858 4 55684500 [T/C] rs2726647 4 55684576 [T/G] rs2646357 4 55685764 [A/G] rs1472411 4 55689495 [T/C] rs2646351 4 55701312 [A/G] rs2726626 4 55703218 [A/G] rs17763012 4 55703257 [T/C] rs1948607 4 55706827 [T/C] rs2270674 4 55715633 [A/G] rs1874653 4 55716601 [A/C] rs1497499 4 55717962 [T/C] rs17084902 4 55718650 [A/G] rs1874647 4 55721469 [A/G] rs2173231 4 55725382 [A/G] rs11727341 4 55733422 [T/C] rs1532460 4 55743651 [A/G] rs6554207 4 55746122 [T/C] rs878120 4 55748445 [A/G] rs904136 4 55748487 [A/G] rs924223 4 55751539 [T/C] rs10010776 4 55752730 [A/G] rs11133348 4 55753059 [A/G] rs12331512 4 55756559 [A/G] rs17085031 4 55760897 [A/G] rs6826975 4 55768206 [T/C] rs6851808 4 55782793 [T/C] rs12642211 4 55786946 [T/C] rs17085113 4 55787043 [T/C] rs969340 4 55790393 [T/C] rs1497482 4 55797131 [A/G] rs2088402 4 55800687 [A/G] rs2067951 4 55805555 [A/C] rs11722442 4 55814774 [T/C] rs4426846 4 55815650 [A/G] rs4345237 4 55818909 [A/G] rs11728462 4 55822867 [A/G] rs7684211 4 55823638 [T/C] rs6554217 4 55831233 [T/C] rs6554218 4 55831694 [A/C] rs6820472 4 55833617 [A/G] rs6835585 4 55839848 [T/G] rs11133355 4 55862338 [T/C] rs12502309 4 55867442 [A/C] rs6842830 4 55873926 [T/C] rs4262039 4 55876463 [A/G] rs13113419 4 55877829 [A/C] rs4864948 4 55879599 [A/G] rs6841800 4 55881411 [T/C] rs4453992 4 55881855 [T/C] rs7658751 4 55885310 [A/G] rs4241988 4 55891531 [A/G] rs13105577 4 55894238 [A/G] rs13142103 4 55899286 [A/G] rs4864949 4 55900647 [A/G] rs7441352 4 55913934 [A/G] rs10461355 4 55921535 [T/G] rs4241991 4 55931246 [A/G] rs4536994 4 55936768 [T/C] rs7691507 4 55943001 [T/C] rs2125489 4 55953483 [A/G] NM_002253 KDR Silent rs1531289 4 55955232 [T/C] NM_002253 KDR Silent rs17709898 4 55957723 [A/G] NM_002253 KDR Silent rs2219471 4 55961159 [T/C] NM_002253 KDR Silent rs6838752 4 55964101 [T/C] NM_002253 KDR Silent rs6828477 4 55966801 [T/C] NM_002253 KDR Silent rs2168945 4 55967483 [A/C] NM_002253 KDR Silent rs11732292 4 55970101 [A/C] NM_002253 KDR Silent rs1870377 4 55972974 [T/A] NM_002253 KDR EXON Missense_Q472H rs7694150 4 55975705 [A/G] NM_002253 KDR Silent rs11941492 4 55978210 [T/C] NM_002253 KDR Silent rs7692791 4 55980239 [T/C] NM_002253 KDR Silent rs6837735 4 55985815 [T/C] NM_002253 KDR Silent rs12502008 4 55991042 [T/G] NM_002253 KDR Silent rs2071559 4 55992366 [A/G] rs10013228 4 55997340 [A/G] rs10517342 4 56002858 [A/G] rs12505096 4 56006102 [A/C] rs12331507 4 56011889 [T/C] rs12331869 4 56012149 [A/G] rs13126206 4 56018295 [A/C] rs1380060 4 56025430 [T/C] rs4356965 4 56025616 [A/G] rs6816309 4 56027518 [T/C] rs2412627 4 56027573 [A/G] rs3986292 4 56029474 [A/C] rs11727885 4 56029834 [T/C] rs6554238 4 56030064 [T/C] rs7659869 4 56030182 [A/G] rs1993583 4 56038620 [A/C] rs1993585 4 56038746 [A/G] rs2085621 4 56044260 [A/G] rs12500524 4 56046659 [T/C] rs13139198 4 56049425 [T/C] rs10017184 4 56055617 [A/G] rs6825269 4 56080348 [A/G] rs10003420 4 56089259 [A/C] rs6858750 4 56090836 [A/G] rs6554248 4 56096263 [T/C] rs6554254 4 56118414 [A/G] rs4241994 4 56125042 [T/C] rs4301169 4 56131739 [T/C] rs6837397 4 56133629 [T/C] rs6843086 4 56134791 [A/G] rs4864976 4 56153732 [T/C] rs7661296 4 56155385 [T/C] rs4077725 4 56157142 [A/G] rs4864539 4 56176481 [A/G] rs1399953 4 56179883 [A/G] rs6829598 4 56180919 [T/G] rs17776421 4 56187375 [A/G] rs11728305 4 56188287 [T/G] rs17085639 4 56190316 [A/G] rs6815518 4 56195626 [A/G] rs7694736 4 56211835 [A/G] rs9790808 4 56214596 [A/G] NM_024592 SRD5A3 Silent rs7664100 4 56222599 [A/G] NM_024592 SRD5A3 Silent rs7663650 4 56231119 [T/C] NM_024592 SRD5A3 Silent rs6852903 4 56232411 [A/G] NM_024592 SRD5A3 Silent rs576732 4 56237137 [T/C] NM_024592,NR_037969 SRD5A3,SRD5A3-AS1 EXON Silent,Silent rs819269 4 56238263 [T/C] NM_024592,NR_037969 SRD5A3,SRD5A3-AS1 EXON Silent,Silent rs819271 4 56238847 [A/G] NM_024592,NR_037969 SRD5A3,SRD5A3-AS1 EXON Silent,Silent rs9993675 4 56243522 [A/G] NR_037969 SRD5A3-AS1 Silent rs552792 4 56246273 [T/C] NR_037969 SRD5A3-AS1 Silent rs693367 4 56260662 [A/G] rs12641881 4 56267473 [T/C] NR_073070,NM_018475 TMEM165,TMEM165 Silent,Silent rs10016977 4 56271942 [T/G] NR_073070,NM_018475 TMEM165,TMEM165 Silent,Silent rs2048564 4 56274132 [A/G] NR_073070,NM_018475 TMEM165,TMEM165 Silent,Silent rs11943456 4 56276334 [T/C] NR_073070,NM_018475 TMEM165,TMEM165 Silent,Silent rs504836 4 56285305 [T/C] NR_073070,NM_018475 TMEM165,TMEM165 Silent,Silent rs534654 4 56290220 [A/G] NR_073070,NM_018475 TMEM165,TMEM165 Silent,Silent rs1047354 4 56295583 [A/G] NM_001267843,NM_004898 CLOCK,CLOCK EXON Silent,Silent rs1056547 4 56296763 [T/G] NM_001267843,NM_004898 CLOCK,CLOCK EXON Silent,Silent rs1801260 4 56301369 [A/G] NM_001267843,NM_004898 CLOCK,CLOCK EXON Silent,Silent rs6855837 4 56319244 [T/G] NM_001267843,NM_004898 CLOCK,CLOCK EXON Missense_L395I,Missense_L395I rs11931061 4 56338793 [A/G] NM_001267843,NM_004898 CLOCK,CLOCK Silent,Silent rs17722979 4 56346411 [A/G] NM_001267843,NM_004898 CLOCK,CLOCK Silent,Silent rs3817444 4 56375981 [A/C] NM_001267843,NM_004898 CLOCK,CLOCK Silent,Silent rs12649507 4 56380484 [A/G] NM_001267843,NM_004898 CLOCK,CLOCK Silent,Silent rs13132420 4 56392813 [A/G] NM_001267843,NM_004898 CLOCK,CLOCK Silent,Silent rs4864548 4 56413803 [A/G] rs1979604 4 56418755 [A/C] rs726967 4 56421713 [T/A] rs7665846 4 56439245 [T/C] NM_152401 PDCL2 Silent rs13133077 4 56443809 [A/G] NM_152401 PDCL2 Silent rs1873092 4 56444300 [T/C] NM_152401 PDCL2 Silent rs2412660 4 56445111 [T/C] NM_152401 PDCL2 Silent rs13132085 4 56460085 [A/G] rs2087319 4 56461365 [A/C] rs12108463 4 56466734 [T/G] NR_120489,NM_006681,NM_001292046,NM_001292045 NMU,NMU,NMU,NMU EXON Silent,Missense_F148L,Missense_F123L,Missense_F132L rs1906678 4 56468485 [T/G] NR_120489,NM_006681,NM_001292046,NM_001292045 NMU,NMU,NMU,NMU Silent,Silent,Silent,Silent rs1873091 4 56471433 [A/G] NR_120489,NM_006681,NM_001292046,NM_001292045 NMU,NMU,NMU,NMU Silent,Silent,Silent,Silent rs3805383 4 56475338 [A/G] NR_120489,NM_006681,NM_001292046,NM_001292045 NMU,NMU,NMU,NMU EXON Silent,Synonymous_N76N,Synonymous_N76N,Synonymous_N60N rs10022874 4 56491887 [T/C] NR_120489,NM_006681,NM_001292046,NM_001292045 NMU,NMU,NMU,NMU Silent,Silent,Silent,Silent rs12499623 4 56492499 [T/G] NR_120489,NM_006681,NM_001292046,NM_001292045 NMU,NMU,NMU,NMU Silent,Silent,Silent,Silent rs12500837 4 56494039 [T/C] NR_120489,NM_006681,NM_001292046,NM_001292045 NMU,NMU,NMU,NMU Silent,Silent,Silent,Silent rs9999653 4 56498249 [T/C] NR_120489,NM_006681,NM_001292046,NM_001292045 NMU,NMU,NMU,NMU Silent,Silent,Silent,Silent rs9312664 4 56499826 [T/G] NR_120489,NM_006681,NM_001292046,NM_001292045 NMU,NMU,NMU,NMU Silent,Silent,Silent,Silent rs3792703 4 56502178 [A/G] NR_120489,NM_006681,NM_001292046,NM_001292045 NMU,NMU,NMU,NMU Silent,Silent,Silent,Silent rs1488938 4 56512574 [A/G] rs10002268 4 56519892 [T/C] rs12506506 4 56526433 [A/G] rs11728776 4 56527767 [T/C] rs2634464 4 56530796 [A/G] rs13132077 4 56530970 [T/C] rs2634466 4 56539449 [T/C] rs4864552 4 56547412 [A/C] rs4288064 4 56551185 [T/C] rs6856478 4 56551916 [A/G] rs6828640 4 56568521 [T/C] rs7665149 4 56581678 [A/G] rs12648836 4 56583590 [A/G] rs7658424 4 56584126 [A/G] rs10014020 4 56596137 [T/G] rs17086027 4 56596913 [A/C] rs4333263 4 56596987 [T/C] rs3923477 4 56599963 [T/C] rs4272068 4 56609540 [A/G] rs10031105 4 56609872 [T/C] rs13142719 4 56615644 [A/G] rs4519853 4 56617884 [T/C] rs6840857 4 56623422 [A/G] rs7667111 4 56623447 [T/C] rs11725155 4 56625468 [A/G] rs12641893 4 56628525 [T/C] rs6816150 4 56629191 [T/C] rs4865034 4 56629771 [T/G] rs7691043 4 56632288 [T/G] rs10517360 4 56635884 [A/G] rs7677808 4 56637488 [T/G] rs10015409 4 56641023 [A/C] rs13113466 4 56641680 [A/G] rs10018255 4 56641791 [A/G] rs7685450 4 56648713 [A/G] rs4078505 4 56648809 [T/C] rs1955161 4 56654246 [A/G] rs2726736 4 56664054 [T/C] rs6554324 4 56667225 [A/G] rs753129 4 56668431 [A/G] rs2899048 4 56671211 [A/C] rs11736419 4 56677652 [T/C] rs13126824 4 56680363 [T/C] rs7679852 4 56683846 [T/C] rs6848009 4 56697597 [A/T] NM_001351574,NM_001351575 EXOC1L,EXOC1L EXON Missense_D73E,Missense_D23E rs12504347 4 56700160 [A/C] NM_001351574,NM_001351575 EXOC1L,EXOC1L Silent,Silent rs2899039 4 56702299 [A/G] NM_001351574,NM_001351575 EXOC1L,EXOC1L Silent,Silent rs1447050 4 56702995 [A/G] NM_001351574,NM_001351575 EXOC1L,EXOC1L Silent,Silent rs6824915 4 56706623 [T/C] rs4865038 4 56717548 [A/G] rs2412692 4 56718312 [T/C] rs7668978 4 56730119 [A/G] NM_018261,NM_178237,NM_001024924 EXOC1,EXOC1,EXOC1 Silent,Silent,Silent rs3213948 4 56734701 [T/C] NM_018261,NM_178237,NM_001024924 EXOC1,EXOC1,EXOC1 Silent,Silent,Silent rs4865041 4 56742205 [A/G] NM_018261,NM_178237,NM_001024924 EXOC1,EXOC1,EXOC1 Silent,Silent,Silent rs17086109 4 56748045 [A/G] NM_018261,NM_178237,NM_001024924 EXOC1,EXOC1,EXOC1 Silent,Silent,Silent rs12646999 4 56754099 [T/C] NM_018261,NM_178237,NM_001024924 EXOC1,EXOC1,EXOC1 Silent,Silent,Silent rs2290016 4 56756531 [T/C] NM_018261,NM_178237,NM_001024924 EXOC1,EXOC1,EXOC1 EXON Synonymous_A506A,Synonymous_A491A,Synonymous_A506A rs1447045 4 56761548 [A/G] NM_018261,NM_178237,NM_001024924 EXOC1,EXOC1,EXOC1 Silent,Silent,Silent rs17086132 4 56762164 [A/G] NM_018261,NM_178237,NM_001024924 EXOC1,EXOC1,EXOC1 Silent,Silent,Silent rs17086150 4 56770708 [A/C] NM_018261,NM_178237,NM_001024924 EXOC1,EXOC1,EXOC1 EXON Silent,Silent,Silent rs11658 4 56771089 [A/G] NM_018261,NM_178237,NM_001024924 EXOC1,EXOC1,EXOC1 EXON Silent,Silent,Silent rs2899046 4 56775270 [A/G] rs2593079 4 56776848 [A/G] rs17086157 4 56777124 [A/G] rs11938985 4 56779258 [A/G] rs12509278 4 56780461 [A/C] rs2593075 4 56786589 [A/C] rs10517365 4 56786831 [T/C] rs2593074 4 56789617 [A/G] rs2702331 4 56796606 [T/C] rs2593072 4 56808242 [T/C] rs2702322 4 56813481 [A/G] rs6836444 4 56814741 [A/G] rs4865047 4 56821806 [T/C] NM_025009 CEP135 Silent rs2593068 4 56829482 [A/G] NM_025009 CEP135 Silent rs3806749 4 56830934 [A/G] NM_025009 CEP135 Silent rs2593087 4 56835309 [T/C] NM_025009 CEP135 Silent rs6838426 4 56839866 [A/C] NM_025009 CEP135 Silent rs6815354 4 56851023 [T/G] NM_025009 CEP135 Silent rs4526032 4 56855667 [A/G] NM_025009 CEP135 Silent rs11133419 4 56864032 [A/G] NM_025009 CEP135 Silent rs13138432 4 56868342 [A/G] NM_025009 CEP135 Silent rs6856844 4 56869217 [T/C] NM_025009 CEP135 Silent rs3214045 4 56874517 [A/C] NM_025009 CEP135 EXON Missense_I769L rs7660872 4 56903251 [T/C] rs12649879 4 56904059 [A/G] rs2951806 4 56905444 [T/C] rs2702340 4 56908194 [A/G] rs2702334 4 56911058 [T/G] rs6839870 4 56924685 [A/G] rs2412717 4 56945325 [A/G] rs2412719 4 56948718 [T/G] rs2412723 4 56951767 [A/G] rs10019724 4 56952163 [A/G] rs10015524 4 56953577 [T/C] rs12331742 4 56955556 [T/C] rs4865050 4 56965175 [A/C] rs13121935 4 56966559 [A/G] rs17799799 4 56968671 [T/G] rs976640 4 56980231 [A/G] rs11728328 4 56986929 [T/C] rs998064 4 56997350 [A/G] rs11133423 4 57001112 [T/C] rs10866432 4 57004959 [T/C] rs13143526 4 57008387 [T/C] rs13144710 4 57008939 [T/C] rs13148796 4 57009127 [T/G] rs11133424 4 57010328 [A/C] rs13105877 4 57016020 [T/C] rs1479008 4 57017493 [A/G] rs11736698 4 57026928 [A/G] rs6818168 4 57028693 [A/C] rs2276901 4 57036306 [A/G] rs11133427 4 57038461 [A/C] NM_020722 KIAA1211 Silent rs10213659 4 57039609 [T/C] NM_020722 KIAA1211 Silent rs10213095 4 57039646 [A/G] NM_020722 KIAA1211 Silent rs11133431 4 57051461 [A/G] NM_020722 KIAA1211 Silent rs6856875 4 57053541 [A/G] NM_020722 KIAA1211 Silent rs11936569 4 57061470 [T/C] NM_020722 KIAA1211 Silent rs17744943 4 57061920 [A/G] NM_020722 KIAA1211 Silent rs4865063 4 57066601 [A/G] NM_020722 KIAA1211 Silent rs2045984 4 57067425 [A/G] NM_020722 KIAA1211 Silent rs1993916 4 57071639 [T/C] NM_020722 KIAA1211 Silent rs7692217 4 57087608 [A/G] NM_020722 KIAA1211 Silent rs962488 4 57090811 [T/C] NM_020722 KIAA1211 Silent rs17086470 4 57091138 [A/C] NM_020722 KIAA1211 Silent rs5012040 4 57092292 [T/G] NM_020722 KIAA1211 Silent rs4865070 4 57093826 [A/G] NM_020722 KIAA1211 Silent rs10020065 4 57095679 [T/C] NM_020722 KIAA1211 Silent rs7685126 4 57095806 [A/G] NM_020722 KIAA1211 Silent rs140645 4 57096491 [T/C] NM_020722 KIAA1211 Silent rs140643 4 57096602 [T/C] NM_020722 KIAA1211 Silent rs7698073 4 57097742 [A/G] NM_020722 KIAA1211 Silent rs1600268 4 57099609 [A/G] NM_020722 KIAA1211 Silent rs1479006 4 57102386 [T/C] NM_020722 KIAA1211 Silent rs10023405 4 57103047 [A/G] NM_020722 KIAA1211 Silent rs1038115 4 57108271 [T/C] NM_020722 KIAA1211 Silent rs12501430 4 57109453 [A/G] NM_020722 KIAA1211 Silent rs1993917 4 57110592 [T/C] NM_020722 KIAA1211 Silent rs13123990 4 57111783 [T/G] NM_020722 KIAA1211 Silent rs11734492 4 57112435 [T/C] NM_020722 KIAA1211 Silent rs4865075 4 57113130 [A/G] NM_020722 KIAA1211 Silent rs7690043 4 57116323 [T/C] NM_020722 KIAA1211 Silent rs11942391 4 57118192 [A/G] NM_020722 KIAA1211 Silent rs6842825 4 57125176 [T/C] NM_020722 KIAA1211 Silent rs598210 4 57126378 [T/C] NM_020722 KIAA1211 Silent rs534208 4 57127117 [T/C] NM_020722 KIAA1211 Silent rs6554340 4 57127848 [A/C] NM_020722 KIAA1211 Silent rs572969 4 57129103 [T/G] NM_020722 KIAA1211 Silent rs536002 4 57134800 [T/C] NM_020722 KIAA1211 Silent rs551289 4 57139331 [A/G] NM_020722 KIAA1211 Silent rs562803 4 57142047 [T/C] NM_020722 KIAA1211 Silent rs629242 4 57143037 [T/C] NM_020722 KIAA1211 Silent rs533178 4 57149650 [A/G] NM_020722 KIAA1211 Silent rs493228 4 57154517 [A/C] NM_020722 KIAA1211 Silent rs490591 4 57154790 [T/C] NM_020722 KIAA1211 Silent rs510411 4 57156379 [A/G] NM_020722 KIAA1211 Silent rs7663149 4 57162619 [A/G] NM_020722 KIAA1211 Silent rs4337783 4 57165323 [A/G] NM_020722 KIAA1211 Silent rs13124016 4 57167280 [A/G] NM_020722 KIAA1211 Silent rs7663516 4 57170069 [T/G] NM_020722 KIAA1211 Silent rs1401910 4 57172978 [T/C] NM_020722 KIAA1211 Silent rs7696217 4 57173047 [T/C] NM_020722 KIAA1211 Silent rs2049087 4 57178227 [T/C] NM_020722 KIAA1211 Silent rs3796547 4 57181995 [T/C] NM_020722 KIAA1211 EXON Missense_S776L rs3822003 4 57182647 [A/G] NM_020722 KIAA1211 EXON Synonymous_A993A rs1401904 4 57187665 [T/G] NM_020722 KIAA1211 Silent rs6854916 4 57188538 [A/G] NM_020722 KIAA1211 Silent rs2292983 4 57190242 [T/C] NM_020722 KIAA1211 Silent rs7695701 4 57190356 [A/G] NM_020722 KIAA1211 EXON Synonymous_R1155R rs6826795 4 57193762 [A/G] NM_020722 KIAA1211 Silent rs11733474 4 57194329 [T/G] NM_020722 KIAA1211 EXON Silent rs939293 4 57196155 [T/C] NM_020722 KIAA1211 EXON Silent rs10013721 4 57203622 [A/C] rs8340 4 57204777 [A/C] NM_001323893,NM_001286668,NM_001323899,NM_181806,NM_001286671,NM_001286670,NM_001323892,NM_001286669,NM_001323890 AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH EXON Silent,Missense_Y930D,Missense_Y653D,Missense_Y1030D,Silent,Missense_Y545D,Silent,Missense_Y877D,Missense_Y1069D rs3733324 4 57204960 [A/G] NM_001323893,NM_001286668,NM_001323899,NM_181806,NM_001286671,NM_001286670,NM_001323892,NM_001286669,NM_001323890 AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3796545 4 57215597 [T/C] NM_001323893,NM_001286668,NM_001323899,NM_181806,NM_001286671,NM_001286670,NM_001323892,NM_001286669,NM_001323890,NM_001286672 AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH EXON Missense_V621I,Missense_V674I,Missense_V397I,Missense_V774I,Missense_V774I,Missense_V289I,Missense_V774I,Missense_V621I,Missense_V774I,Missense_V774I rs3796544 4 57215677 [A/G] NM_001323893,NM_001286668,NM_001323899,NM_181806,NM_001286671,NM_001286670,NM_001323892,NM_001286669,NM_001323890,NM_001286672 AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH EXON Missense_A594V,Missense_A647V,Missense_A370V,Missense_A747V,Missense_A747V,Missense_A262V,Missense_A747V,Missense_A594V,Missense_A747V,Missense_A747V rs17086696 4 57219613 [T/C] NM_001323893,NM_001286668,NM_001323899,NM_181806,NM_001286671,NM_001286670,NM_001323892,NM_001286669,NM_001323890,NM_001286672 AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH EXON Synonymous_P358P,Synonymous_P411P,Synonymous_P134P,Synonymous_P511P,Synonymous_P511P,Synonymous_P26P,Synonymous_P511P,Synonymous_P358P,Synonymous_P511P,Synonymous_P511P rs3796543 4 57221348 [T/C] NM_001323893,NM_001286668,NM_001323899,NM_181806,NM_001286671,NM_001286670,NM_001323892,NM_001286669,NM_001323890,NM_001286672 AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH EXON Missense_K215R,Missense_K268R,Missense_S27G,Missense_K368R,Missense_K368R,Silent,Missense_K368R,Missense_K215R,Missense_K368R,Missense_K368R rs13102012 4 57224519 [A/G] NM_001323893,NM_001286668,NM_001323899,NM_181806,NM_001286671,NM_001286670,NM_001323892,NM_001286669,NM_001323890,NM_001286672 AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6554354 4 57237683 [A/G] NM_001323893,NM_001286668,NM_001323899,NM_181806,NM_001286671,NM_001286670,NM_001323892,NM_001286669,NM_001323890,NM_001286672 AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH EXON Synonymous_S112S,Synonymous_S165S,Silent,Synonymous_S265S,Synonymous_S265S,Silent,Synonymous_S265S,Synonymous_S112S,Synonymous_S265S,Synonymous_S265S rs13150967 4 57246019 [A/G] NM_001323893,NM_001286668,NM_001323899,NM_181806,NM_001286671,NM_001286670,NM_001323892,NM_001286669,NM_001323890,NM_001286672 AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH,AASDH Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7671868 4 57256201 [T/C] rs4493603 4 57258537 [T/C] rs1060472 4 57259465 [A/C] rs17086746 4 57259999 [T/C] NR_156493,NM_002703 PPAT,PPAT EXON Silent,Silent rs1401908 4 57285163 [T/C] NR_156493,NM_002703 PPAT,PPAT Silent,Silent rs13147824 4 57297996 [T/C] NR_156493,NM_002703 PPAT,PPAT Silent,Silent rs1520026 4 57300557 [T/C] NR_156493,NM_002703 PPAT,PPAT Silent,Silent rs1356787 4 57305202 [T/C] NM_006452,NM_001079525,NM_001079524 PAICS,PAICS,PAICS Silent,Silent,Silent rs1967559 4 57305699 [A/G] NM_006452,NM_001079525,NM_001079524 PAICS,PAICS,PAICS Silent,Silent,Silent rs6825812 4 57314986 [A/T] NM_006452,NM_001079525,NM_001079524 PAICS,PAICS,PAICS EXON Missense_K228N,Missense_K235N,Missense_K228N rs6584 4 57327405 [T/C] NM_006452,NM_001079525,NM_001079524 PAICS,PAICS,PAICS EXON Silent,Silent,Silent rs7693436 4 57327613 [A/G] rs13143904 4 57332288 [T/C] rs4270628 4 57341262 [A/C] NM_001267722,NR_151856,NM_006947 SRP72,SRP72,SRP72 Silent,Silent,Silent rs17086832 4 57345195 [T/C] NM_001267722,NR_151856,NM_006947 SRP72,SRP72,SRP72 Silent,Silent,Silent rs12508008 4 57353767 [A/G] NM_001267722,NR_151856,NM_006947 SRP72,SRP72,SRP72 Silent,Silent,Silent rs6834809 4 57361477 [A/C] NM_001267722,NR_151856,NM_006947 SRP72,SRP72,SRP72 Silent,Silent,Silent rs11934479 4 57361627 [A/C] NM_001267722,NR_151856,NM_006947 SRP72,SRP72,SRP72 Silent,Silent,Silent rs10015634 4 57362827 [A/G] NM_001267722,NR_151856,NM_006947 SRP72,SRP72,SRP72 Silent,Silent,Silent rs17086912 4 57367805 [T/C] NM_001267722,NR_151856,NM_006947 SRP72,SRP72,SRP72 Silent,Silent,Silent rs4260596 4 57368413 [A/G] NM_001267722,NR_151856,NM_006947 SRP72,SRP72,SRP72 EXON Silent,Silent,Silent rs14211 4 57368759 [A/G] NM_001267722,NR_151856,NM_006947 SRP72,SRP72,SRP72 EXON Silent,Silent,Silent rs12644498 4 57372630 [T/C] NM_206919,NM_001363794 ARL9,ARL9 Silent,Silent rs10004163 4 57378399 [A/G] NM_206919,NM_001363794 ARL9,ARL9 Silent,Silent rs4131086 4 57385455 [A/G] NM_206919,NM_001363794 ARL9,ARL9 Silent,Silent rs4391105 4 57387706 [A/G] NM_206919,NM_001363794 ARL9,ARL9 Silent,Silent rs17086939 4 57390650 [T/C] rs4865115 4 57397910 [T/G] NM_001256475 THEGL Silent rs4280802 4 57398752 [T/C] NM_001256475 THEGL Silent rs4473708 4 57410548 [A/C] NM_001256475 THEGL Silent rs7691920 4 57418400 [A/G] NM_001256475 THEGL Silent rs7686452 4 57426688 [T/C] NM_001256475 THEGL Silent rs10213489 4 57434245 [T/C] NM_001256475 THEGL Silent rs4600976 4 57442004 [A/C] NM_001256475 THEGL Silent rs9996055 4 57444413 [A/G] NM_001256475 THEGL Silent rs4345238 4 57450848 [A/C] NM_001256475 THEGL Silent rs10006458 4 57457048 [T/C] NM_001256475 THEGL Silent rs7670824 4 57457918 [A/G] NM_001256475 THEGL Silent rs4864589 4 57459490 [A/G] NM_001256475 THEGL Silent rs7699631 4 57477794 [A/G] rs4415019 4 57479891 [A/G] rs10013558 4 57489378 [T/C] rs4865131 4 57498446 [T/C] rs7667406 4 57503077 [A/G] rs11944014 4 57513910 [T/C] rs12649154 4 57513912 [A/C] rs4371677 4 57516896 [A/G] NM_001145459,NM_139212,NM_032495,NM_139211,NM_001145460 HOPX,HOPX,HOPX,HOPX,HOPX EXON Silent,Silent,Silent,Silent,Missense_P94L rs4406078 4 57521325 [T/C] NM_001145459,NM_139212,NM_032495,NM_139211,NM_001145460 HOPX,HOPX,HOPX,HOPX,HOPX Silent,Silent,Silent,Silent,Silent rs4864593 4 57525831 [T/C] NM_139212,NM_032495,NM_001145460 HOPX,HOPX,HOPX Silent,Silent,Silent rs6817875 4 57526349 [A/C] NM_139212,NM_032495,NM_001145460 HOPX,HOPX,HOPX Silent,Silent,Silent rs6823211 4 57526500 [T/C] NM_139212,NM_032495,NM_001145460 HOPX,HOPX,HOPX Silent,Silent,Silent rs6824757 4 57527444 [A/G] NM_139212,NM_032495,NM_001145460 HOPX,HOPX,HOPX Silent,Silent,Silent rs6830271 4 57527586 [T/C] NM_139212,NM_032495,NM_001145460 HOPX,HOPX,HOPX Silent,Silent,Silent rs6836932 4 57528443 [T/C] NM_139212,NM_032495,NM_001145460 HOPX,HOPX,HOPX Silent,Silent,Silent rs4864594 4 57529014 [A/C] NM_139212,NM_032495,NM_001145460 HOPX,HOPX,HOPX Silent,Silent,Silent rs4865140 4 57537199 [A/C] NM_139212,NM_032495,NM_001145460 HOPX,HOPX,HOPX Silent,Silent,Silent rs9654326 4 57537412 [A/G] NM_139212,NM_032495,NM_001145460 HOPX,HOPX,HOPX Silent,Silent,Silent rs11721616 4 57542454 [T/C] NM_139212,NM_032495,NM_001145460 HOPX,HOPX,HOPX Silent,Silent,Silent rs12642085 4 57549528 [T/C] rs4865142 4 57549583 [T/C] rs6829867 4 57549603 [T/C] rs17087059 4 57550335 [A/G] rs6849557 4 57550870 [T/C] rs899628 4 57552810 [A/G] rs6828831 4 57555103 [T/C] rs9968381 4 57558426 [T/C] rs6845520 4 57564095 [A/G] rs11729059 4 57564293 [T/G] rs12644752 4 57573446 [T/C] rs6816355 4 57575299 [T/C] rs11725915 4 57586154 [T/C] rs973031 4 57587795 [T/C] rs1383028 4 57590071 [A/G] rs4864599 4 57597210 [A/G] rs4865148 4 57606444 [A/G] rs1842295 4 57608969 [T/C] rs10222715 4 57614160 [T/G] rs6830854 4 57621843 [A/G] rs6818605 4 57624037 [A/G] rs6811987 4 57629710 [T/C] rs10033814 4 57637951 [A/G] rs9992616 4 57648046 [A/C] rs2412757 4 57649159 [A/C] rs2008139 4 57652380 [A/G] rs13146442 4 57674397 [C/G] rs11724060 4 57677345 [A/C] NM_001271721,NM_001271720,NM_021114,NM_001271722,NR_073418,NR_073417,NR_073419,NM_001271719,NM_001271718 SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17087176 4 57678832 [A/G] NM_001271721,NM_001271720,NM_021114,NM_001271722,NR_073418,NR_073417,NR_073419,NM_001271719,NM_001271718 SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13102386 4 57680805 [T/C] NM_001271721,NM_001271720,NM_021114,NM_001271722,NR_073418,NR_073417,NR_073419,NM_001271719,NM_001271718 SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs812991 4 57686657 [A/G] NM_001271721,NM_001271720,NM_021114,NM_001271722,NR_073418,NR_073417,NR_073419,NM_001271719,NM_001271718 SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs781542 4 57687304 [A/G] NM_001271721,NM_001271720,NM_021114,NM_001271722,NR_073418,NR_073417,NR_073419,NM_001271719,NM_001271718 SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2,SPINK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1708768 4 57690713 [A/G] rs1708772 4 57694352 [A/G] rs1399002 4 57695126 [A/G] rs2127495 4 57696918 [A/G] rs7668497 4 57700528 [A/G] rs781571 4 57705970 [T/C] rs781570 4 57705999 [A/C] rs781565 4 57707469 [A/G] rs781564 4 57708245 [A/C] rs751356 4 57713324 [T/C] rs13106200 4 57718195 [A/G] rs1708774 4 57726274 [T/C] rs7684253 4 57727311 [T/C] rs796681 4 57730683 [T/C] rs17087206 4 57731189 [A/G] rs9637714 4 57731446 [T/C] rs12650282 4 57733604 [T/C] rs11730321 4 57738469 [T/C] rs4560473 4 57741415 [T/C] rs2170073 4 57746825 [A/G] rs6848165 4 57749080 [T/C] rs9998008 4 57766052 [A/G] rs3806746 4 57773330 [T/C] rs1713985 4 57786450 [T/G] NM_005612,NM_001193508,NM_001363453 REST,REST,REST Silent,Silent,Silent rs6847086 4 57791864 [A/G] NM_005612,NM_001193508,NM_001363453 REST,REST,REST Silent,Silent,Silent rs3796529 4 57797414 [T/C] NM_005612,NM_001193508,NM_001363453 REST,REST,REST EXON Missense_P797L,Missense_P797L,Missense_P797L rs708547 4 57821309 [T/C] rs17087289 4 57821682 [T/C] rs7668814 4 57825190 [T/C] rs1718839 4 57827206 [A/G] rs9996543 4 57828432 [A/G] rs11932673 4 57833203 [T/C] NM_032313 NOA1 Silent rs17087335 4 57838583 [T/G] NM_032313 NOA1 Silent rs1107674 4 57838690 [T/G] NM_032313 NOA1 Silent rs1107675 4 57838707 [T/C] NM_032313 NOA1 Silent rs1713998 4 57844902 [A/G] NM_001303268,NM_001303269,NM_000938 POLR2B,POLR2B,POLR2B EXON Silent,Silent,Silent rs13133792 4 57845269 [T/G] NM_001303268,NM_001303269,NM_000938 POLR2B,POLR2B,POLR2B Silent,Silent,Silent rs1625691 4 57845740 [T/C] NM_001303268,NM_001303269,NM_000938 POLR2B,POLR2B,POLR2B Silent,Silent,Silent rs1277281 4 57856092 [A/G] NM_001303268,NM_001303269,NM_000938 POLR2B,POLR2B,POLR2B Silent,Silent,Silent rs10002090 4 57859592 [T/C] NM_001303268,NM_001303269,NM_000938 POLR2B,POLR2B,POLR2B Silent,Silent,Silent rs1718837 4 57871203 [T/C] NM_001303268,NM_001303269,NM_000938 POLR2B,POLR2B,POLR2B Silent,Silent,Silent rs7661194 4 57872421 [T/C] NM_001303268,NM_001303269,NM_000938 POLR2B,POLR2B,POLR2B Silent,Silent,Silent rs1718878 4 57876955 [A/G] NM_001303268,NM_001303269,NM_000938 POLR2B,POLR2B,POLR2B EXON Synonymous_A455A,Synonymous_A523A,Synonymous_A530A rs1713982 4 57881715 [A/G] NM_001303268,NM_001303269,NM_000938 POLR2B,POLR2B,POLR2B EXON Synonymous_T541T,Synonymous_T609T,Synonymous_T616T rs2271806 4 57887150 [T/C] NM_001303268,NM_001303269,NM_000938 POLR2B,POLR2B,POLR2B EXON Synonymous_R728R,Synonymous_R796R,Synonymous_R803R rs13146153 4 57887252 [A/G] NM_001303268,NM_001303269,NM_000938 POLR2B,POLR2B,POLR2B Silent,Silent,Silent rs7440152 4 57889288 [A/G] NM_001303268,NM_001303269,NM_000938 POLR2B,POLR2B,POLR2B Silent,Silent,Silent rs1056364 4 57889677 [T/C] NM_001303268,NM_001303269,NM_000938 POLR2B,POLR2B,POLR2B EXON Synonymous_S824S,Synonymous_S892S,Synonymous_S899S rs4865171 4 57892643 [A/G] NM_001303268,NM_001303269,NM_000938 POLR2B,POLR2B,POLR2B Silent,Silent,Silent rs1277308 4 57897864 [T/C] NM_001553 IGFBP7 Silent rs11573128 4 57898230 [T/G] NM_001553 IGFBP7 Silent rs2271808 4 57899602 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs12642622 4 57902276 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1277311 4 57902761 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs11133472 4 57904387 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs11573119 4 57904852 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1718885 4 57905453 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs11133474 4 57905807 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs7687211 4 57906335 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1277273 4 57909291 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs6852762 4 57910214 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs3821996 4 57915267 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs6554404 4 57916237 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs881382 4 57917346 [T/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1713973 4 57918245 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1718834 4 57918904 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1401189 4 57919919 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1713963 4 57921706 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs11573086 4 57922249 [A/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1713959 4 57922990 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs7656865 4 57926736 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs11573078 4 57929799 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1277293 4 57931341 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs7356193 4 57933375 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs17761305 4 57934091 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs4865174 4 57934971 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs10516161 4 57936735 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1714020 4 57937134 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs10516163 4 57937511 [T/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs13141016 4 57937862 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs11934877 4 57941026 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1714014 4 57941160 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1718848 4 57942581 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1714010 4 57942649 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs11573056 4 57942687 [A/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1718845 4 57943153 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs10009533 4 57943382 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1713976 4 57944503 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs3806744 4 57945439 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs11936912 4 57947022 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1718858 4 57948187 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs1718861 4 57949699 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs7695536 4 57955234 [T/C] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs4865181 4 57963469 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs4865182 4 57963611 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs10004910 4 57968444 [A/G] NM_001553,NM_001253835 IGFBP7,IGFBP7 Silent,Silent rs4326070 4 57977479 [A/G] NR_034081 IGFBP7-AS1 Silent rs13129156 4 57981557 [A/G] NR_034081 IGFBP7-AS1 Silent rs6828580 4 57987433 [A/G] NR_034081 IGFBP7-AS1 Silent rs4327548 4 57999268 [A/G] NR_034081 IGFBP7-AS1 Silent rs4444899 4 58005459 [A/G] NR_034081 IGFBP7-AS1 Silent rs6847938 4 58012501 [T/C] NR_034081 IGFBP7-AS1 Silent rs6816917 4 58012732 [A/G] NR_034081 IGFBP7-AS1 Silent rs9996990 4 58013351 [T/C] NR_034081 IGFBP7-AS1 Silent rs7663355 4 58015591 [T/C] NR_034081 IGFBP7-AS1 Silent rs4579186 4 58015899 [A/G] NR_034081 IGFBP7-AS1 Silent rs6817385 4 58020126 [T/C] NR_034081 IGFBP7-AS1 Silent rs7677987 4 58020760 [A/G] NR_034081 IGFBP7-AS1 Silent rs10033422 4 58027081 [A/G] NR_034081 IGFBP7-AS1 Silent rs4516785 4 58028209 [A/G] NR_034081 IGFBP7-AS1 Silent rs12641603 4 58031795 [A/G] NR_034081 IGFBP7-AS1 Silent rs7654584 4 58032848 [A/C] NR_034081 IGFBP7-AS1 Silent rs11133488 4 58036217 [T/C] NR_034081 IGFBP7-AS1 Silent rs4412045 4 58041751 [T/C] NR_034081 IGFBP7-AS1 Silent rs6857279 4 58053743 [T/C] NR_034081 IGFBP7-AS1 Silent rs13145188 4 58055260 [T/C] NR_034081 IGFBP7-AS1 Silent rs17497594 4 58056503 [T/C] NR_034081 IGFBP7-AS1 Silent rs10014421 4 58064464 [T/C] NR_034081 IGFBP7-AS1 Silent rs10488926 4 58066486 [A/G] NR_034081 IGFBP7-AS1 Silent rs2215473 4 58066825 [A/G] NR_034081 IGFBP7-AS1 Silent rs2098159 4 58072736 [T/C] rs2079916 4 58072932 [A/G] rs6853264 4 58075747 [T/C] rs917674 4 58077421 [A/G] rs17425871 4 58081173 [T/G] rs1860622 4 58081623 [A/G] rs4865199 4 58082554 [T/C] rs6812462 4 58085224 [A/G] rs1860621 4 58087036 [T/C] rs7680799 4 58088414 [T/C] rs7698838 4 58088682 [T/C] rs2109589 4 58094886 [T/C] rs9995833 4 58098249 [T/C] rs6822293 4 58098494 [T/C] rs12500068 4 58098554 [T/C] rs17425986 4 58100571 [A/G] rs6856352 4 58102272 [A/G] rs9999844 4 58102553 [A/G] rs4865204 4 58103527 [T/C] rs2191567 4 58104161 [T/C] rs2109588 4 58104275 [T/C] rs1981687 4 58104571 [T/C] rs11934184 4 58105295 [T/C] rs4865205 4 58106366 [T/C] rs7679409 4 58107030 [A/C] rs13147707 4 58108131 [T/C] rs1990404 4 58115768 [A/G] rs11731338 4 58116921 [A/G] rs6815861 4 58120471 [T/C] rs6833012 4 58120699 [T/G] rs13132470 4 58121404 [T/G] rs10016362 4 58121589 [A/C] rs17087830 4 58121668 [T/C] rs917680 4 58121894 [T/G] rs917677 4 58122141 [T/C] rs13115696 4 58122195 [A/G] rs6825426 4 58123111 [A/G] rs17498104 4 58136368 [T/C] rs4865209 4 58136668 [A/G] rs2191576 4 58136698 [T/C] rs10018606 4 58138412 [A/G] rs1476844 4 58139970 [T/C] rs17426309 4 58140768 [T/C] rs2191574 4 58141367 [T/C] rs2041437 4 58145935 [T/C] rs4865211 4 58146502 [A/G] rs7686067 4 58146929 [A/C] rs6838965 4 58148873 [T/C] rs17498431 4 58150716 [A/G] rs6813950 4 58154936 [T/C] rs1524698 4 58156935 [A/C] rs1524696 4 58161061 [A/G] rs6840839 4 58170360 [A/C] rs2691402 4 58171793 [T/G] rs2535523 4 58178243 [T/C] rs991920 4 58178960 [A/G] rs1524686 4 58179993 [T/C] rs2535516 4 58184590 [A/G] rs2535511 4 58189742 [T/C] rs715208 4 58191253 [T/C] rs2245144 4 58193150 [T/G] rs1524671 4 58193776 [T/C] rs1917335 4 58194612 [A/G] rs1829982 4 58195063 [T/C] rs2535503 4 58195196 [T/C] rs2535498 4 58196071 [T/C] rs1404370 4 58196685 [T/C] rs2177642 4 58197731 [A/G] rs940572 4 58198454 [A/G] rs1524672 4 58199809 [A/G] rs10021529 4 58202128 [T/C] rs1404372 4 58203605 [A/C] rs17087996 4 58207586 [T/C] rs987706 4 58209517 [T/G] rs2222560 4 58216884 [A/G] rs10022224 4 58218215 [A/G] rs6811739 4 58219609 [T/G] rs6853593 4 58239085 [T/C] rs1608687 4 58240010 [T/C] rs10024454 4 58248207 [T/C] rs13129010 4 58261728 [A/G] rs10009611 4 58263866 [A/C] rs2204370 4 58264562 [A/G] rs10517394 4 58271686 [A/G] rs1012189 4 58272001 [A/G] rs1012188 4 58272082 [T/C] rs10517393 4 58272528 [T/G] rs6847118 4 58275617 [T/G] rs10155292 4 58277976 [A/G] rs9917898 4 58285434 [T/C] rs839021 4 58289649 [T/C] rs1851999 4 58293063 [T/G] NR_125907 LINC02380 Silent rs940580 4 58296141 [T/G] NR_125907 LINC02380 Silent rs6554464 4 58296826 [T/C] NR_125907 LINC02380 Silent rs1372088 4 58298691 [A/G] NR_125907 LINC02380 Silent rs940578 4 58298856 [A/G] NR_125907 LINC02380 Silent rs7668422 4 58299763 [T/C] NR_125907 LINC02380 Silent rs7663056 4 58301148 [T/C] NR_125907 LINC02380 Silent rs7661860 4 58301224 [A/G] NR_125907 LINC02380 Silent rs839036 4 58302458 [T/G] NR_125907 LINC02380 Silent rs13101487 4 58303358 [A/G] NR_125907 LINC02380 Silent rs6821078 4 58308959 [T/C] NR_125907 LINC02380 Silent rs6827688 4 58309910 [A/C] NR_125907 LINC02380 Silent rs1561660 4 58313925 [T/C] NR_125907 LINC02380 Silent rs11937087 4 58314264 [A/G] NR_125907 LINC02380 Silent rs6855484 4 58320842 [A/G] NR_125907 LINC02380 Silent rs11133493 4 58324740 [T/C] NR_125907 LINC02380 Silent rs4864624 4 58326265 [A/C] NR_125907 LINC02380 Silent rs7669775 4 58332294 [T/C] rs10020991 4 58332757 [A/C] rs12331888 4 58335056 [T/C] rs12650171 4 58340913 [T/C] rs7654918 4 58350599 [T/G] rs13102887 4 58350801 [T/G] rs7696759 4 58350816 [A/C] rs12646772 4 58352102 [T/C] rs1345040 4 58352237 [A/G] rs17832655 4 58352345 [A/G] rs4865234 4 58355015 [A/G] rs11735670 4 58355701 [T/C] rs11931710 4 58356623 [T/G] rs4865236 4 58363063 [T/C] rs1372094 4 58381197 [T/C] rs1441073 4 58396399 [A/C] rs2028435 4 58408330 [T/G] rs17088360 4 58412269 [T/C] rs17088362 4 58412380 [A/C] rs17088371 4 58413456 [A/G] rs17088409 4 58444318 [T/C] rs1583881 4 58445149 [T/C] rs2899092 4 58450181 [T/C] rs13117119 4 58457282 [A/G] rs7693389 4 58464353 [A/G] rs4608868 4 58470680 [A/G] rs13129234 4 58474857 [A/G] rs13120218 4 58476824 [A/G] rs7697011 4 58477126 [A/G] rs6840178 4 58477962 [T/C] rs12643621 4 58479112 [A/G] rs4557336 4 58480066 [A/G] rs4599476 4 58480567 [T/G] rs4865252 4 58481417 [T/C] rs4438813 4 58483725 [A/G] rs4438814 4 58484281 [A/G] rs11731283 4 58484885 [T/G] rs1469235 4 58491683 [A/G] rs4865256 4 58501865 [A/C] rs17088477 4 58513545 [T/C] rs1425316 4 58515319 [T/C] rs10517402 4 58518911 [T/C] rs1425320 4 58522592 [A/G] rs4864632 4 58522810 [T/C] rs4865257 4 58526596 [T/C] rs17088485 4 58528741 [T/C] rs1364824 4 58536904 [A/G] rs4276345 4 58546539 [A/C] rs1425309 4 58550290 [T/C] rs343503 4 58560611 [A/G] rs343501 4 58566621 [A/C] rs11736736 4 58573210 [A/G] rs482084 4 58586920 [T/C] rs12647976 4 58589128 [A/G] rs17088636 4 58592926 [A/G] rs17088644 4 58597247 [T/G] rs9790425 4 58598522 [A/G] rs1509535 4 58604281 [T/C] rs343549 4 58614509 [T/C] rs343554 4 58616162 [T/C] rs11937364 4 58624691 [T/C] rs17088666 4 58625182 [A/G] rs343592 4 58631640 [T/C] rs1509537 4 58639261 [A/C] rs343566 4 58642656 [T/G] rs189353 4 58646143 [T/G] rs1509528 4 58655901 [T/C] rs10034684 4 58662041 [T/G] rs6814709 4 58662227 [T/C] rs6831719 4 58662408 [A/G] rs13126470 4 58662671 [T/C] rs13134774 4 58664089 [A/C] rs17088743 4 58668729 [T/C] rs11933998 4 58669378 [A/C] rs2899102 4 58670132 [A/G] rs951232 4 58670994 [T/C] rs979119 4 58671636 [A/G] rs4865283 4 58674284 [T/C] rs1509531 4 58684651 [A/G] rs6848712 4 58689383 [T/C] rs1509539 4 58692467 [T/C] rs7679186 4 58696072 [T/G] rs12505795 4 58696511 [T/G] rs10011661 4 58698487 [T/C] rs10019628 4 58698638 [A/G] rs9312691 4 58700119 [T/C] rs3843894 4 58700901 [T/C] rs13134527 4 58702130 [A/G] rs1904778 4 58702467 [A/G] rs983355 4 58703510 [A/G] rs982034 4 58703879 [A/G] rs1480321 4 58704841 [T/C] rs17088782 4 58704924 [A/G] rs10020207 4 58706462 [T/C] rs1480319 4 58707016 [A/G] rs922605 4 58714407 [A/G] rs1480298 4 58727238 [T/C] rs1480301 4 58727290 [A/G] rs17088829 4 58727901 [A/G] rs17088834 4 58728612 [T/C] rs17088838 4 58738371 [T/C] rs2412857 4 58739725 [T/C] rs6840157 4 58748479 [A/G] rs10517417 4 58750042 [A/G] rs17088873 4 58758713 [A/G] rs17794379 4 58760786 [A/G] rs10517418 4 58768454 [T/C] rs6822760 4 58768658 [A/G] rs9884270 4 58770663 [A/G] rs9992403 4 58772260 [T/C] rs952004 4 58775268 [T/C] rs1480332 4 58782909 [A/C] rs10025162 4 58784132 [A/G] rs17088917 4 58791086 [A/G] rs7657187 4 58793000 [T/C] rs1480308 4 58796884 [T/G] rs17088952 4 58799916 [T/C] rs6554506 4 58807069 [T/G] rs11133536 4 58809621 [T/G] rs17088964 4 58810453 [A/G] rs10001131 4 58810492 [T/C] rs9637716 4 58811360 [T/C] rs17088981 4 58815257 [A/G] rs10015020 4 58827259 [A/G] rs11936360 4 58832860 [T/C] rs10008425 4 58837610 [T/C] rs17237378 4 58840510 [T/C] rs1383233 4 58842939 [T/C] rs6822367 4 58849291 [A/G] rs11946236 4 58851934 [A/G] rs3912236 4 58854092 [T/C] rs13134586 4 58857424 [A/G] rs3913924 4 58860052 [A/C] rs270464 4 58861963 [T/G] rs971794 4 58888972 [T/C] rs10013416 4 58900069 [T/C] rs10033389 4 58901889 [T/C] rs4865293 4 58904987 [A/C] rs1507578 4 58907784 [T/C] rs1948974 4 58908653 [A/G] rs10028399 4 58912736 [A/G] rs1380196 4 58913500 [A/C] rs1380198 4 58922725 [A/G] rs2174809 4 58923439 [A/G] rs270233 4 58933127 [A/G] rs930937 4 58935390 [T/G] rs2660943 4 58935943 [A/G] rs270245 4 58940551 [T/G] rs270244 4 58940617 [T/C] rs781589 4 58941933 [A/G] rs781588 4 58942148 [A/G] rs1507583 4 58955664 [A/G] rs1531305 4 58960261 [A/G] rs17290180 4 58960389 [T/G] rs17290187 4 58960829 [T/G] rs2610166 4 58961150 [A/G] rs1911605 4 58967480 [T/C] rs12504646 4 58971838 [A/G] rs17089110 4 58974923 [T/C] rs1433418 4 58984954 [A/G] rs4864644 4 58991684 [T/G] rs17237553 4 58994093 [T/C] rs13115208 4 58995218 [A/G] rs12506735 4 59003803 [A/G] rs1433409 4 59006847 [A/G] rs1433408 4 59006971 [A/G] rs1563772 4 59007188 [T/G] rs10517437 4 59008412 [A/G] rs2117065 4 59008961 [T/C] rs1080057 4 59026944 [T/C] rs3943387 4 59028886 [A/G] rs892307 4 59031089 [T/C] rs12646025 4 59035958 [T/C] rs17827154 4 59036816 [A/G] rs10005074 4 59042209 [T/C] rs1865182 4 59050934 [A/G] rs2611162 4 59072672 [T/C] rs11940034 4 59091204 [T/C] rs2412882 4 59108872 [T/G] rs10007387 4 59113239 [T/C] rs2570085 4 59117179 [A/C] rs13105776 4 59133280 [T/C] rs2553297 4 59139089 [T/C] rs2553296 4 59141562 [T/C] rs17237658 4 59156538 [T/C] rs2570069 4 59156851 [A/G] rs1915903 4 59177075 [T/C] rs11937322 4 59180928 [A/G] rs12648067 4 59211129 [A/G] rs7666786 4 59217237 [T/C] rs17089256 4 59217565 [T/C] rs1522093 4 59217612 [A/G] rs1522094 4 59221416 [T/C] rs10015715 4 59252047 [T/C] rs12642751 4 59273187 [A/G] rs1222269 4 59275372 [T/C] rs2140069 4 59279104 [A/G] rs935999 4 59284649 [T/G] rs11937415 4 59285092 [T/C] rs1222271 4 59304973 [A/G] rs17218168 4 59319223 [A/G] rs2037458 4 59321537 [A/G] rs1840239 4 59335942 [A/G] rs12647734 4 59338580 [T/C] rs11133566 4 59345914 [A/G] rs1463323 4 59348360 [T/C] rs13121688 4 59360441 [A/G] rs4864655 4 59362260 [T/C] rs10007576 4 59369235 [T/C] rs17290361 4 59369515 [A/C] rs11937554 4 59375202 [T/C] rs10007616 4 59375444 [A/C] rs1453939 4 59377333 [A/C] rs7667901 4 59378549 [T/C] rs11133570 4 59388759 [A/G] rs9999484 4 59406749 [T/C] rs6818886 4 59408250 [A/G] rs4242018 4 59413750 [T/C] rs13109943 4 59413971 [A/C] rs10517441 4 59419273 [T/C] rs13114819 4 59423332 [A/G] rs9996466 4 59436076 [T/C] rs282722 4 59444611 [T/C] rs282720 4 59445288 [T/C] rs282745 4 59452393 [A/G] rs12647295 4 59481416 [T/G] rs17218287 4 59484288 [T/C] rs1605774 4 59489084 [T/C] rs2662841 4 59491899 [A/G] rs10031559 4 59497894 [T/C] rs282705 4 59502687 [T/C] rs282706 4 59502974 [A/G] rs282710 4 59507265 [A/G] rs1565822 4 59515454 [A/G] rs1396579 4 59520026 [T/C] rs9994974 4 59535533 [T/C] rs1961726 4 59541966 [T/C] rs10033443 4 59548868 [T/C] rs1828204 4 59550505 [T/C] rs10004285 4 59559715 [A/G] rs4865352 4 59564300 [A/G] rs4865353 4 59565589 [A/C] rs1396576 4 59567739 [A/G] rs13115335 4 59572909 [A/G] rs17089553 4 59573186 [T/C] rs6850334 4 59576664 [A/C] rs4864659 4 59577435 [T/C] rs1472926 4 59582759 [A/G] rs1027867 4 59595781 [A/G] rs10005244 4 59604951 [T/C] rs9993637 4 59605202 [T/C] rs17290480 4 59606624 [T/C] rs1868416 4 59621853 [A/G] rs10517447 4 59627178 [A/G] rs6843830 4 59629835 [T/G] rs7666280 4 59633011 [A/C] rs10011039 4 59636452 [T/G] rs6829904 4 59637473 [A/G] rs6813611 4 59637674 [T/C] rs7691858 4 59645426 [T/C] rs10517449 4 59667025 [T/C] rs1992941 4 59673037 [T/C] rs1449031 4 59673650 [A/G] rs10517450 4 59677511 [T/C] rs13147033 4 59686485 [T/C] rs2122155 4 59689961 [A/G] rs17237994 4 59697508 [A/C] rs12502978 4 59710106 [A/G] rs1868419 4 59713040 [T/C] rs9998639 4 59715417 [T/C] rs7685041 4 59720431 [A/G] rs1900867 4 59727134 [A/C] rs7685795 4 59799035 [T/C] rs9997522 4 59799872 [A/C] rs4074334 4 59805404 [T/G] rs7436625 4 59806257 [T/C] rs7440797 4 59809260 [T/C] rs9685766 4 59813594 [T/C] rs7667163 4 59817797 [T/C] rs6551609 4 59819545 [T/C] rs7659089 4 59832091 [A/G] rs13101913 4 59833499 [A/G] rs6819968 4 59835266 [A/G] rs11932542 4 59842999 [A/G] rs9942216 4 59843855 [A/G] rs11931812 4 59844473 [T/C] rs11734556 4 59847627 [T/C] rs13112623 4 59866889 [T/C] NR_133941 LINC02429 Silent rs4860200 4 59867437 [T/G] NR_133941 LINC02429 Silent rs11733784 4 59869101 [T/C] NR_133941 LINC02429 Silent rs1495722 4 59869371 [T/C] NR_133941 LINC02429 Silent rs12649958 4 59878013 [T/C] NR_133941 LINC02429 Silent rs6849738 4 59889898 [T/G] NR_133941,NR_133942 LINC02429,LINC02429 Silent,Silent rs10002245 4 59899352 [T/C] NR_133941,NR_133942 LINC02429,LINC02429 Silent,Silent rs7667333 4 59900914 [T/G] NR_133941,NR_133942 LINC02429,LINC02429 Silent,Silent rs13111434 4 59906337 [T/C] NR_133941,NR_133942 LINC02429,LINC02429 EXON Silent,Silent rs10452251 4 59906632 [A/G] NR_133941,NR_133942 LINC02429,LINC02429 Silent,Silent rs11131211 4 59908346 [T/C] NR_133941,NR_133942 LINC02429,LINC02429 Silent,Silent rs2036098 4 59916674 [T/C] rs17089341 4 59924709 [A/G] rs17089354 4 59929358 [T/C] rs10034214 4 59930697 [A/G] rs7674325 4 59932187 [T/G] rs11131237 4 59937751 [A/G] rs2132341 4 59938858 [A/G] rs2333727 4 59950731 [A/G] rs11729950 4 59965367 [T/C] rs1155335 4 59970766 [A/G] rs13151697 4 59980062 [T/C] rs357833 4 59988095 [A/G] rs13134467 4 59998696 [A/G] rs3114023 4 60005301 [T/C] rs2055486 4 60010116 [A/G] rs439122 4 60010750 [A/G] rs10021662 4 60013350 [T/C] rs13347305 4 60013919 [T/C] rs12498186 4 60016213 [A/G] rs357809 4 60016378 [T/C] rs364737 4 60021921 [T/G] rs2270970 4 60041691 [T/C] rs2134445 4 60048376 [T/G] rs11722985 4 60054426 [T/C] rs4489000 4 60059161 [A/C] rs7681389 4 60079490 [A/G] rs1354254 4 60082188 [T/C] rs964384 4 60088172 [T/G] rs12646524 4 60096626 [T/C] rs6855237 4 60099156 [T/C] rs995678 4 60104294 [T/C] rs990147 4 60106143 [T/C] rs17827688 4 60111876 [A/G] rs1502784 4 60112029 [A/G] rs17089537 4 60127335 [A/G] rs7663467 4 60129168 [A/G] rs10002811 4 60129838 [T/C] rs7693572 4 60143686 [T/C] rs13134179 4 60149217 [A/G] rs13135277 4 60149698 [A/G] rs7440788 4 60155189 [T/C] rs6836709 4 60156592 [A/G] rs9312092 4 60164589 [A/G] rs17089560 4 60176254 [T/C] rs17089569 4 60178068 [A/G] rs10014071 4 60179526 [A/G] rs966998 4 60183194 [T/C] rs7683276 4 60192397 [A/G] rs17290640 4 60192809 [A/G] rs10008176 4 60193870 [T/C] rs17089590 4 60200132 [A/G] rs10022990 4 60217601 [T/C] rs1119950 4 60228517 [A/G] rs10866134 4 60239646 [A/G] rs1983239 4 60249365 [A/G] rs4860530 4 60257120 [T/G] rs4860532 4 60257400 [A/G] rs7681982 4 60257454 [T/C] rs17089646 4 60266310 [T/C] rs1606137 4 60268638 [A/G] rs1079463 4 60275069 [T/C] rs1511404 4 60283466 [A/C] rs4860580 4 60325010 [T/C] rs13143351 4 60325495 [T/G] rs1858317 4 60340339 [A/G] rs1511408 4 60344490 [A/G] rs1117491 4 60347355 [A/G] rs17238233 4 60356966 [T/C] rs6811282 4 60367869 [T/C] rs10007020 4 60391854 [T/C] rs11131575 4 60393064 [A/G] rs17218618 4 60399836 [A/G] rs11131579 4 60401751 [A/C] rs17089687 4 60403334 [T/C] rs1913311 4 60405703 [T/G] rs17089693 4 60418595 [T/C] rs1513536 4 60428730 [A/G] rs17290779 4 60442490 [T/C] rs970313 4 60458820 [A/G] rs1600954 4 60465326 [T/G] rs7439432 4 60468539 [A/G] rs1482701 4 60475482 [T/C] rs988744 4 60480763 [T/C] rs6842739 4 60489510 [A/G] rs1825238 4 60493470 [T/G] rs7683528 4 60495394 [T/C] rs17290786 4 60496226 [T/G] rs1482699 4 60500708 [T/C] rs10013542 4 60512343 [T/C] rs7670505 4 60521038 [T/C] rs7655641 4 60521175 [A/C] rs1482704 4 60529334 [A/G] rs17089731 4 60532077 [T/C] rs1513532 4 60532584 [T/C] rs17089744 4 60536694 [A/G] rs35712489 4 60536829 [T/C] rs1032030 4 60538549 [T/C] rs1395652 4 60549283 [A/G] rs17089747 4 60549462 [T/G] rs17290842 4 60551659 [T/C] rs10025215 4 60553750 [T/G] rs17218730 4 60560780 [A/G] rs9991718 4 60568412 [T/G] rs17089765 4 60568798 [A/G] rs17238366 4 60569262 [T/C] rs11936764 4 60573507 [A/G] rs6552029 4 60578593 [T/C] rs2880170 4 60581437 [A/G] rs1023951 4 60597973 [A/G] rs1023948 4 60598813 [T/C] rs17089786 4 60616622 [T/C] rs1507132 4 60619937 [A/G] rs7699730 4 60621100 [A/C] rs4600947 4 60627772 [A/G] rs10002873 4 60639488 [T/C] rs10005469 4 60639822 [T/C] rs17290974 4 60658933 [A/G] rs13148808 4 60664578 [T/G] rs7697784 4 60673647 [T/C] rs9312186 4 60674843 [T/C] rs1863308 4 60678416 [A/G] rs17089834 4 60680656 [T/C] rs1010849 4 60687024 [T/C] rs12499997 4 60707711 [T/C] rs4401481 4 60715255 [T/C] rs1304686 4 60729234 [T/G] rs6815012 4 60730605 [A/G] rs17089860 4 60741765 [T/G] rs12647148 4 60742316 [T/C] rs17089867 4 60746052 [T/C] rs13131266 4 60751925 [A/C] rs12640622 4 60756570 [T/C] rs7655523 4 60757025 [T/C] rs1559703 4 60774654 [T/C] rs1834384 4 60776281 [A/C] rs1903298 4 60793034 [A/G] rs2553401 4 60800714 [A/G] rs28823272 4 60815480 [T/G] rs13112895 4 60826699 [T/C] rs349247 4 60829098 [T/G] rs349240 4 60830710 [T/C] rs349235 4 60833758 [A/G] rs349215 4 60843933 [A/G] rs349211 4 60844380 [T/C] rs349203 4 60846394 [T/G] rs10461286 4 60853613 [A/C] rs11946874 4 60854084 [A/G] rs1993672 4 60855477 [A/C] rs6551510 4 60856792 [A/G] rs7674332 4 60860482 [A/G] rs17291023 4 60866816 [T/G] rs9312045 4 60873322 [T/G] rs2880475 4 60874182 [A/G] rs12645408 4 60879952 [T/C] rs12650519 4 60885848 [T/G] rs17291044 4 60891956 [T/C] rs11947191 4 60892141 [T/C] rs1460339 4 60902170 [A/G] rs17089920 4 60904464 [A/G] rs2085777 4 60908435 [T/C] rs10517488 4 60918911 [A/G] rs12644729 4 60929487 [T/C] rs7656343 4 60930593 [T/C] rs531673 4 60931418 [T/C] rs531622 4 60931440 [T/C] rs2119551 4 60941032 [T/G] rs1109023 4 60946148 [A/C] rs6832310 4 60946433 [A/G] rs17291120 4 60965262 [A/G] rs7695675 4 60969122 [A/G] rs4530671 4 60973349 [A/G] rs10009793 4 60977518 [A/G] rs1441314 4 60978783 [T/C] rs6551519 4 60984101 [T/G] rs12511090 4 61007315 [A/G] rs10049506 4 61008776 [T/C] rs4146901 4 61029597 [T/C] rs4262013 4 61041872 [A/G] rs10461289 4 61046610 [A/G] rs1372202 4 61047629 [A/G] rs6817774 4 61055763 [T/C] rs13117217 4 61059339 [A/G] rs2165479 4 61065522 [A/G] rs17089992 4 61072814 [A/G] rs7681003 4 61074614 [T/G] rs6820884 4 61080364 [A/C] rs11131228 4 61080750 [T/C] rs4277806 4 61107712 [T/C] rs3924779 4 61110086 [A/G] rs6834427 4 61126692 [A/G] rs2334124 4 61133934 [T/C] rs13434729 4 61141856 [T/C] rs10517502 4 61154338 [T/C] rs717252 4 61163718 [T/C] rs4241633 4 61170648 [A/G] rs7672373 4 61173570 [A/G] rs6827408 4 61177831 [T/C] rs4860334 4 61178793 [A/G] rs6848703 4 61181195 [T/C] rs7673099 4 61187284 [A/C] rs1455731 4 61194055 [T/C] rs9992970 4 61195576 [A/C] rs10517499 4 61207237 [T/C] rs4412021 4 61207691 [T/C] rs17090019 4 61208481 [T/G] rs12501945 4 61210632 [T/G] rs10866099 4 61211180 [A/C] rs1947493 4 61216054 [A/G] rs6551541 4 61220878 [T/C] rs6833291 4 61226507 [T/C] rs10019682 4 61228770 [T/C] rs17081849 4 61231636 [A/G] rs1463351 4 61233219 [T/C] rs11946495 4 61238161 [T/G] rs17090036 4 61240227 [A/G] rs13143552 4 61244872 [T/C] rs4860340 4 61247315 [T/C] rs4318679 4 61249246 [A/G] rs6852865 4 61251815 [T/C] rs17090042 4 61254423 [A/G] rs6858288 4 61258122 [T/C] rs10517496 4 61262697 [A/G] rs1378566 4 61264831 [T/C] rs6551546 4 61265932 [A/G] rs4499722 4 61266555 [A/G] rs1869765 4 61274340 [T/C] rs7690448 4 61276747 [T/C] rs9990505 4 61278746 [A/C] rs6853921 4 61290298 [T/C] rs12511553 4 61292539 [T/G] rs980051 4 61296108 [T/C] rs3911391 4 61305996 [T/C] rs1350085 4 61310371 [T/C] rs17219303 4 61316400 [T/G] rs925395 4 61317176 [A/G] rs1553863 4 61319052 [T/C] rs6551553 4 61321240 [A/G] rs994342 4 61339224 [T/C] rs10517505 4 61345972 [T/C] rs10021608 4 61352529 [A/G] rs1397649 4 61353754 [T/C] rs997107 4 61356693 [A/G] rs4602520 4 61360284 [T/C] rs11728006 4 61360679 [A/C] rs9884208 4 61363382 [A/G] rs11131258 4 61365718 [T/C] rs12641304 4 61366704 [T/C] rs6551565 4 61367078 [T/C] rs10030930 4 61368571 [T/C] rs6852374 4 61370159 [A/G] rs1588514 4 61371578 [A/C] rs7660113 4 61371895 [A/G] rs7688499 4 61384046 [T/G] rs1553862 4 61395456 [A/C] rs9990993 4 61402680 [A/G] rs17090118 4 61402738 [A/G] rs1912682 4 61404788 [T/C] rs6857178 4 61407562 [A/C] rs12645705 4 61422632 [T/C] rs1439310 4 61424207 [A/G] rs13103913 4 61440626 [T/C] rs1511124 4 61441659 [A/C] rs13125772 4 61443447 [T/G] rs13146560 4 61446054 [T/C] rs11131268 4 61484551 [A/C] rs6843734 4 61497064 [A/G] rs2028315 4 61504139 [T/C] rs975734 4 61507007 [A/G] rs9996373 4 61511878 [T/C] rs17090230 4 61513458 [T/C] rs7669975 4 61514117 [T/G] rs1898848 4 61519303 [T/C] rs1898851 4 61526204 [T/G] rs1439317 4 61528903 [T/C] rs10024649 4 61529037 [T/G] rs1439299 4 61533457 [T/C] rs7662547 4 61539305 [A/G] rs1439294 4 61541738 [T/G] rs11932579 4 61552142 [T/C] rs4535361 4 61552933 [A/G] rs9884903 4 61555937 [A/G] rs4860361 4 61588040 [T/C] rs4460023 4 61589454 [A/G] rs4309865 4 61590894 [T/C] rs10012618 4 61592332 [T/C] rs10050170 4 61602645 [T/C] rs13132569 4 61603156 [A/C] rs7679019 4 61603501 [T/C] rs4510484 4 61603973 [A/G] rs4527515 4 61612126 [A/G] rs4394027 4 61621387 [A/G] rs12504712 4 61626653 [T/C] rs6849233 4 61628548 [A/G] rs13109616 4 61629652 [T/C] rs9995171 4 61634572 [A/G] rs4496609 4 61641564 [A/G] rs4072938 4 61654288 [A/G] rs4272045 4 61663916 [A/G] rs12648062 4 61666777 [A/G] rs17081884 4 61675083 [T/C] rs6848209 4 61678747 [A/C] rs17090281 4 61685448 [A/C] rs17219586 4 61687774 [T/C] rs1378360 4 61688725 [A/C] rs17090284 4 61695508 [T/C] rs4611956 4 61696791 [T/C] rs17291739 4 61709761 [T/G] rs11725567 4 61724114 [T/C] rs10019200 4 61725276 [T/C] rs10012645 4 61729184 [A/G] rs1455268 4 61738094 [T/C] rs17090295 4 61738470 [T/G] rs6826243 4 61739960 [T/C] rs1455286 4 61753646 [T/C] rs7670391 4 61762647 [A/C] rs716167 4 61767946 [T/C] rs1455280 4 61771431 [A/G] rs10000438 4 61773762 [T/C] rs9312059 4 61773790 [A/G] rs6823258 4 61781801 [T/G] rs10022351 4 61788908 [A/G] rs10517518 4 61795416 [A/G] rs6851977 4 61799685 [T/C] rs2045199 4 61800185 [T/G] rs2604632 4 61803301 [A/G] rs2631054 4 61809210 [A/G] rs11131284 4 61823479 [A/G] rs12642913 4 61825087 [A/G] rs1486488 4 61825240 [A/C] rs1486492 4 61830190 [A/G] rs901388 4 61832236 [A/C] rs1486493 4 61836190 [T/C] rs1906073 4 61837133 [A/C] rs2341734 4 61842588 [T/C] rs8180200 4 61846956 [A/G] rs10014515 4 61847376 [T/C] rs13129872 4 61848154 [A/G] rs7699903 4 61855451 [A/G] rs12641314 4 61860937 [T/C] rs6831772 4 61866264 [T/C] rs13119110 4 61871415 [T/C] rs1486498 4 61872079 [T/C] rs10006348 4 61894078 [T/G] rs4860078 4 61900003 [T/C] rs12501471 4 61903366 [A/G] rs6813806 4 61908999 [T/C] rs725761 4 61911862 [T/C] rs10031140 4 61914877 [T/G] rs966084 4 61917658 [T/C] rs17090351 4 61921234 [A/G] rs9884795 4 61946476 [A/G] rs7699691 4 61948488 [T/C] rs10030728 4 61950476 [A/G] rs17090360 4 61950968 [T/G] rs10018237 4 61953065 [T/C] rs4599440 4 61966273 [T/C] rs7439943 4 61967025 [A/G] rs1449618 4 61975533 [A/G] rs10517524 4 61982096 [A/G] rs2034448 4 61984568 [T/C] rs12506236 4 61987337 [T/C] rs1900957 4 61992249 [A/G] rs10866114 4 61998057 [T/G] rs10006264 4 62002328 [A/G] rs930668 4 62004333 [A/G] rs1470645 4 62007979 [T/C] rs12186207 4 62015576 [A/C] NR_147148 LINC02271 Silent rs1375680 4 62017472 [A/C] NR_147148 LINC02271 Silent rs1375681 4 62037705 [A/G] rs1449613 4 62044559 [A/G] rs2218741 4 62049284 [A/G] rs998666 4 62052467 [A/C] rs6841219 4 62061051 [T/C] rs1505659 4 62074758 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6854914 4 62076443 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6845545 4 62080215 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6825047 4 62084538 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs12499198 4 62088597 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17090416 4 62098937 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs924940 4 62100860 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1827770 4 62104112 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs11131314 4 62106989 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1505682 4 62111856 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1979111 4 62113587 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs974541 4 62121348 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2342456 4 62124053 [A/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10517529 4 62130085 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1505663 4 62132090 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1505664 4 62132345 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs4860406 4 62136915 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs12505990 4 62140177 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs9312075 4 62143023 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs7435420 4 62150059 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs9998310 4 62159915 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs12508911 4 62160473 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17828306 4 62162828 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17090424 4 62163043 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs7695405 4 62163509 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2880363 4 62167906 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs13151711 4 62172534 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2135242 4 62188118 [A/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1505679 4 62198201 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10032294 4 62208968 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs11729528 4 62210266 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1456863 4 62213988 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6826967 4 62225105 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17828324 4 62225605 [A/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs4860411 4 62229733 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6858223 4 62240526 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10866117 4 62242432 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17219773 4 62244228 [T/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs9684510 4 62251012 [A/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs9312076 4 62251077 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17090446 4 62255222 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2124793 4 62256029 [T/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17238968 4 62256068 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2061266 4 62258836 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17238975 4 62268153 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs13127162 4 62269277 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1456866 4 62271604 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1563532 4 62273266 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1350246 4 62276356 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs7683598 4 62283822 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10428284 4 62283836 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17238982 4 62284310 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs11946870 4 62284505 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs11945414 4 62289223 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6824906 4 62290252 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2124794 4 62290634 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6821028 4 62293449 [A/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1037671 4 62301359 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1026419 4 62303163 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs7661450 4 62303629 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2643036 4 62316572 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10009335 4 62317170 [T/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs335336 4 62333348 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs335328 4 62344439 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs335324 4 62349873 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17090481 4 62354522 [T/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10016690 4 62359319 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs335271 4 62361459 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10008278 4 62366666 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs335286 4 62368762 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17090492 4 62373539 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10029192 4 62380911 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs335306 4 62381539 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs335317 4 62387140 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs335305 4 62393760 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6813884 4 62398938 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17226207 4 62399244 [A/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs11734047 4 62402002 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs904243 4 62406445 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1565901 4 62407327 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17090504 4 62410156 [T/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs7656189 4 62411676 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs9312078 4 62412292 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2132074 4 62416499 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1497917 4 62416593 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10011995 4 62418658 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2343249 4 62419426 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs958862 4 62434848 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs723120 4 62434977 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6841033 4 62442507 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17239080 4 62455462 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs11131334 4 62457454 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1497901 4 62461940 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs35550109 4 62462234 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs9996810 4 62468670 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10001410 4 62474229 [A/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs7666147 4 62478230 [A/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17239101 4 62495735 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs987749 4 62497320 [A/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs12642037 4 62503837 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1497921 4 62526281 [T/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs4860425 4 62542957 [A/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs12233859 4 62545435 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs12510774 4 62563504 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6843311 4 62568688 [T/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6843246 4 62585617 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6848408 4 62585789 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs9998713 4 62586313 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs9312082 4 62599289 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs4640696 4 62606930 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs12646895 4 62616180 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2343577 4 62626565 [T/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2345049 4 62637158 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs12509742 4 62645032 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6815347 4 62651583 [A/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1901223 4 62660731 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs4493573 4 62665721 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs7683391 4 62676117 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs11724057 4 62686490 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2345042 4 62686499 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs11734607 4 62693692 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2345041 4 62698357 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10021525 4 62707476 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10021694 4 62707653 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6551661 4 62716210 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10446786 4 62726874 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs34855831 4 62728124 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6551665 4 62739541 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6846033 4 62739674 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1947275 4 62744545 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs9683662 4 62748384 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6858066 4 62754320 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs11131347 4 62759270 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1349408 4 62766445 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17226314 4 62766970 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs4860442 4 62773995 [T/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1355368 4 62779822 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs12648453 4 62788111 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10023425 4 62788474 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2305339 4 62800554 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs734644 4 62800728 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 EXON Synonymous_N693N,Synonymous_N761N,Synonymous_N693N rs10008326 4 62823663 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1510925 4 62830533 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1510923 4 62834741 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17239219 4 62835607 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs7672853 4 62838634 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1397548 4 62845490 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 EXON Synonymous_P937P,Synonymous_P1005P,Synonymous_P937P rs4860106 4 62850522 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17292128 4 62851157 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10017760 4 62856659 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs954645 4 62859511 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs6824673 4 62862615 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs17828558 4 62863411 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs9884445 4 62882928 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1510920 4 62883431 [A/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1510921 4 62895592 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs2058764 4 62911349 [A/G] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs1397546 4 62915024 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs11736888 4 62923797 [T/C] NM_015236,NM_001322402,NM_001322246 ADGRL3,ADGRL3,ADGRL3 Silent,Silent,Silent rs10032372 4 62944634 [T/G] NR_110595 ADGRL3-AS1 Silent rs3922274 4 62945462 [A/G] NR_110595 ADGRL3-AS1 Silent rs10030005 4 62953487 [T/C] NR_110595 ADGRL3-AS1 Silent rs7697748 4 62990100 [A/G] NR_110595 ADGRL3-AS1 Silent rs12715708 4 62994770 [A/G] NR_110595 ADGRL3-AS1 Silent rs7676979 4 63000769 [A/G] NR_110595 ADGRL3-AS1 Silent rs10014304 4 63000920 [A/G] NR_110595 ADGRL3-AS1 Silent rs6857895 4 63012413 [T/C] NR_110595 ADGRL3-AS1 Silent rs1124974 4 63037324 [T/C] rs7440496 4 63038015 [A/G] rs2193120 4 63042975 [A/G] rs4860459 4 63058607 [T/C] rs17292254 4 63059629 [A/G] rs4446347 4 63060580 [T/C] rs1563796 4 63067995 [T/C] rs11735441 4 63083178 [T/C] rs2015977 4 63083363 [A/C] rs6823272 4 63084429 [A/G] rs7694238 4 63096403 [T/G] rs11931064 4 63188592 [A/G] rs1478528 4 63195550 [T/C] rs9994927 4 63214913 [A/G] rs7663110 4 63223986 [T/C] rs7661900 4 63224055 [T/G] rs13137382 4 63229194 [A/G] rs10001214 4 63229994 [T/C] rs7692732 4 63239289 [T/C] rs778940 4 63244085 [T/C] rs10033123 4 63246560 [A/G] rs2169814 4 63247984 [A/C] rs11131367 4 63250043 [T/C] rs778959 4 63255019 [A/C] rs988932 4 63257642 [T/G] rs778933 4 63258582 [T/G] rs10517821 4 63258627 [T/G] rs801454 4 63258843 [T/G] rs778950 4 63263936 [T/C] rs1983497 4 63281335 [A/G] rs1830310 4 63288507 [T/C] rs1590068 4 63293938 [T/G] rs1528375 4 63296955 [T/C] rs2445034 4 63309015 [T/C] rs778572 4 63309789 [T/C] rs11946748 4 63312810 [A/G] rs17828750 4 63314242 [T/C] rs2697201 4 63315877 [A/C] rs17239472 4 63319526 [T/C] rs778554 4 63322306 [T/G] rs1378353 4 63328348 [T/C] rs985591 4 63331949 [T/C] rs12640895 4 63338415 [T/C] rs13140211 4 63341773 [T/C] rs13107417 4 63350062 [A/G] rs6843214 4 63354303 [A/G] rs17292275 4 63355299 [A/G] rs17082777 4 63361327 [A/G] rs10027570 4 63366728 [A/G] rs1000226 4 63370926 [T/C] rs2168263 4 63371659 [T/C] rs12108508 4 63372524 [A/G] rs13126803 4 63378266 [T/G] rs6830305 4 63379063 [A/G] rs6817682 4 63391971 [T/C] rs6848319 4 63397548 [T/G] rs969607 4 63403138 [A/G] rs7699771 4 63407474 [A/C] rs2168267 4 63407579 [T/C] rs13116204 4 63409453 [T/G] rs7670184 4 63416030 [T/C] rs11944965 4 63424089 [T/C] rs1031536 4 63428054 [A/G] rs10022230 4 63440241 [T/G] rs6854419 4 63448853 [A/C] rs4379088 4 63458896 [T/C] rs4348128 4 63467034 [T/C] rs4355419 4 63482692 [A/C] rs7690075 4 63487723 [A/G] rs11941453 4 63493963 [A/G] rs12500171 4 63509409 [T/C] rs3887103 4 63525643 [A/G] rs13137221 4 63533684 [A/G] rs11933934 4 63535629 [T/C] rs4280764 4 63539931 [T/C] rs10013579 4 63540378 [T/C] rs12509725 4 63541157 [T/G] rs6551714 4 63558975 [A/G] rs11131395 4 63562828 [A/G] rs4860481 4 63566758 [A/C] rs6815661 4 63579914 [T/C] rs3922569 4 63614842 [T/C] rs12508568 4 63618186 [T/G] rs4286556 4 63628599 [T/G] rs4473678 4 63648085 [T/C] rs4527510 4 63649153 [T/C] rs7441398 4 63653135 [T/G] rs6821629 4 63661150 [T/G] rs11131413 4 63667799 [T/C] rs11131415 4 63679630 [A/G] rs4860484 4 63680211 [A/C] rs10027721 4 63689854 [T/C] rs11727577 4 63701231 [A/G] rs12233752 4 63704039 [T/C] rs1395745 4 63704307 [A/G] rs2036639 4 63713604 [A/C] rs12649725 4 63718434 [A/G] rs6551725 4 63730296 [A/C] rs6551726 4 63731916 [T/C] rs906345 4 63734689 [T/C] rs17658230 4 63735874 [T/C] rs7665173 4 63739496 [T/C] rs1395738 4 63739803 [A/C] rs4470662 4 63747908 [A/G] rs4269203 4 63748261 [A/G] rs10213657 4 63750632 [T/G] rs17083027 4 63754993 [T/G] rs1507317 4 63763762 [T/G] rs13107261 4 63768826 [A/G] rs4565107 4 63769930 [T/C] rs12374362 4 63779288 [T/C] rs11932508 4 63785436 [T/C] rs7668525 4 63788331 [A/G] rs1395728 4 63811369 [A/C] rs1507315 4 63824453 [T/C] rs17083151 4 63835544 [A/C] rs10025992 4 63838796 [A/G] rs2660598 4 63842062 [A/G] rs6811772 4 63848400 [A/G] rs6843828 4 63856049 [A/C] rs1395733 4 63856523 [T/C] rs1507308 4 63859056 [T/G] rs2262680 4 63863977 [A/G] rs2683405 4 63867349 [A/C] rs2683408 4 63871886 [T/C] rs9312100 4 63872125 [T/C] rs10029207 4 63878877 [T/C] rs9996786 4 63879707 [A/G] rs10213271 4 63883185 [A/G] rs17083254 4 63887305 [T/C] rs2346648 4 63895857 [T/C] rs2346649 4 63901724 [A/G] rs7693548 4 63901897 [T/C] rs10033067 4 63945658 [A/C] rs11725964 4 63955218 [T/C] rs4397025 4 63958237 [T/C] rs7691018 4 63988942 [T/C] rs2171748 4 63992411 [A/G] rs12502749 4 64001013 [A/C] rs17669484 4 64010031 [T/G] rs4522894 4 64066404 [A/G] rs4493574 4 64073599 [A/G] rs13127900 4 64076557 [A/G] rs976921 4 64076807 [T/C] rs2881626 4 64080016 [T/C] rs996473 4 64099349 [A/C] rs13144816 4 64103715 [A/G] rs6837749 4 64118963 [A/G] rs9996258 4 64119829 [A/G] rs9999371 4 64120486 [T/C] rs922333 4 64121298 [T/C] rs1381737 4 64122349 [T/G] rs2346937 4 64125181 [A/C] rs10050111 4 64138341 [T/C] rs4364292 4 64140731 [A/G] rs969726 4 64148129 [A/G] rs11131441 4 64149387 [T/C] rs17083582 4 64150666 [A/G] rs17083593 4 64155302 [A/G] rs9996025 4 64166391 [A/G] rs2346939 4 64171187 [T/C] rs17671382 4 64174876 [T/C] rs17083621 4 64176939 [A/G] rs1870906 4 64180587 [T/C] rs10005499 4 64182495 [T/G] rs1982616 4 64184644 [T/C] rs994855 4 64193699 [A/G] rs7662456 4 64214915 [T/C] rs10050307 4 64217228 [T/C] rs11730204 4 64228349 [T/G] rs12503849 4 64229023 [A/G] rs559669 4 64233091 [T/C] rs1462622 4 64238559 [A/G] rs17672372 4 64243373 [T/C] rs13353631 4 64253631 [A/G] rs10007651 4 64259569 [A/G] rs549815 4 64275466 [T/C] rs12501961 4 64282069 [A/G] rs13105340 4 64295154 [T/C] rs12647475 4 64299915 [T/G] rs2347407 4 64305801 [T/C] rs17627822 4 64308401 [T/C] rs1514950 4 64309441 [A/G] rs6551774 4 64313453 [T/C] rs7689785 4 64315104 [T/C] rs1399531 4 64315661 [T/C] rs17628227 4 64316145 [A/C] rs972651 4 64329169 [A/C] rs2102701 4 64330224 [T/C] rs13133029 4 64332005 [T/C] rs10021833 4 64333810 [A/G] rs2090189 4 64337600 [T/C] rs11131461 4 64342824 [T/C] rs9996032 4 64354567 [A/C] rs1399529 4 64359342 [T/C] rs1399530 4 64359382 [A/G] rs11131464 4 64360700 [T/C] rs6840705 4 64380403 [A/C] rs13118127 4 64390049 [A/C] rs6855459 4 64404377 [T/C] rs7663493 4 64442439 [A/G] rs1020711 4 64461794 [A/G] rs12507316 4 64468573 [A/G] rs12648875 4 64474350 [T/C] rs12500270 4 64475210 [T/G] rs4413438 4 64476938 [T/G] rs1456851 4 64481771 [T/C] rs17083921 4 64483900 [A/C] rs10452252 4 64484803 [T/G] rs12507969 4 64484975 [A/G] rs1456848 4 64485837 [T/G] rs1157023 4 64489926 [T/C] rs7692181 4 64500994 [T/C] rs1020712 4 64511939 [T/C] rs1531202 4 64514978 [A/C] rs2881716 4 64535584 [T/C] rs1456859 4 64552324 [A/G] rs1379148 4 64561082 [A/C] rs10025060 4 64611539 [A/G] rs7659497 4 64612436 [A/G] rs7693102 4 64619384 [T/C] rs13146719 4 64625606 [T/C] rs4860553 4 64662510 [A/G] rs17636187 4 64662777 [T/C] rs17636490 4 64668177 [T/C] rs2347833 4 64686848 [T/C] rs12715741 4 64693032 [T/G] rs13145757 4 64719180 [A/G] rs6853280 4 64719762 [A/G] rs11131484 4 64727794 [T/C] rs1375469 4 64759742 [A/C] rs1349182 4 64772647 [T/C] rs2678065 4 64775396 [T/C] rs1878564 4 64791788 [A/G] rs7672785 4 64831824 [T/C] rs2122206 4 64853008 [A/G] rs1449191 4 64881166 [T/C] rs12647624 4 64888674 [A/C] rs11932534 4 64892027 [T/G] rs2881806 4 64900987 [A/G] rs7660090 4 64904758 [T/G] rs1449187 4 64933680 [A/C] rs17697056 4 64948753 [T/G] rs1402142 4 64970948 [A/C] rs10002861 4 64976578 [T/C] rs12511207 4 65053136 [A/G] rs9312127 4 65085452 [A/G] rs12649001 4 65085505 [A/G] rs17084566 4 65094141 [T/C] rs1483716 4 65097893 [T/C] rs1531864 4 65102656 [A/C] rs2128887 4 65108929 [A/G] rs2200231 4 65114074 [A/G] rs7691568 4 65117251 [A/C] rs972537 4 65134786 [A/G] rs972536 4 65134819 [T/C] rs7660406 4 65137246 [A/G] rs1483713 4 65142710 [T/C] NM_001363796 TECRL EXON Silent rs2348311 4 65148362 [T/C] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs11930994 4 65164696 [T/C] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs7656244 4 65170415 [A/C] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs10011095 4 65189839 [T/C] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs17084662 4 65200217 [A/G] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs282241 4 65206589 [A/G] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs1384725 4 65215475 [A/G] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs1552211 4 65217836 [T/G] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs17084731 4 65225307 [T/C] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs10025479 4 65231389 [A/G] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs1483293 4 65235696 [A/G] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs10049939 4 65252628 [A/G] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs17084784 4 65258550 [T/C] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs13151311 4 65264183 [A/C] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs11727042 4 65265753 [T/G] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs7690664 4 65265927 [T/G] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs1483288 4 65270357 [A/C] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs17084842 4 65273961 [T/C] NM_001363796,NM_001010874 TECRL,TECRL Silent,Silent rs1384720 4 65275649 [A/C] rs6828446 4 65304222 [A/G] rs4510490 4 65305086 [A/G] rs1842955 4 65309678 [T/C] rs12501821 4 65309971 [A/G] rs10002960 4 65313065 [T/C] rs10517889 4 65313497 [T/G] rs13434443 4 65313753 [T/C] rs2086735 4 65324353 [A/C] rs2714933 4 65330689 [A/G] rs11725219 4 65343461 [A/G] rs2086731 4 65346967 [T/C] rs6851961 4 65351771 [A/G] rs10471121 4 65361943 [T/G] rs9991586 4 65367088 [A/G] rs13105217 4 65382034 [T/C] rs1425395 4 65384957 [A/G] rs1425392 4 65392212 [T/C] rs10032135 4 65403406 [T/G] rs1035709 4 65408723 [A/G] rs17663093 4 65412694 [T/C] rs9918005 4 65423635 [T/C] rs1425377 4 65436643 [A/G] rs1425376 4 65437395 [A/G] rs7688529 4 65439260 [A/G] rs6551838 4 65451606 [T/C] rs10024736 4 65453210 [A/G] rs7664375 4 65459781 [A/C] rs10021202 4 65464297 [T/C] rs10212780 4 65475782 [T/C] rs10007849 4 65480701 [T/G] rs1991222 4 65493709 [T/C] rs11943670 4 65501422 [T/G] rs1425390 4 65501761 [A/C] rs11131555 4 65508643 [A/G] rs7340852 4 65510169 [T/C] rs4403082 4 65510635 [T/C] rs4403083 4 65510729 [A/C] rs34725769 4 65511504 [T/C] rs766818 4 65512619 [T/G] rs11937285 4 65513391 [A/G] rs4613600 4 65514219 [A/G] rs10028130 4 65517439 [T/C] rs11131559 4 65519108 [A/C] rs7678201 4 65519866 [T/C] rs4604083 4 65521501 [A/G] rs4645247 4 65530986 [A/G] rs6831411 4 65535470 [A/G] rs6811404 4 65549349 [T/C] rs6828768 4 65556925 [T/C] rs4355422 4 65557183 [T/C] rs4075197 4 65563678 [A/G] rs9995377 4 65572162 [A/G] rs6819000 4 65574910 [T/G] rs7685391 4 65576097 [A/G] rs7695636 4 65586360 [A/G] rs12639640 4 65592228 [A/G] rs17085254 4 65603201 [A/C] rs10026811 4 65608259 [A/C] rs6847583 4 65613269 [A/G] rs1367342 4 65616248 [T/G] rs1074431 4 65620087 [T/C] rs1430519 4 65624721 [T/C] rs17085291 4 65637013 [A/G] rs10031874 4 65638986 [T/C] rs17085296 4 65640223 [T/C] rs6551871 4 65643064 [A/C] rs1346841 4 65651730 [A/G] rs11731709 4 65654988 [A/G] rs1430512 4 65662699 [T/C] rs1346839 4 65675052 [T/C] rs978067 4 65682693 [A/C] rs6551878 4 65690589 [T/G] rs17085407 4 65697696 [A/G] rs7654975 4 65711998 [A/G] rs6818012 4 65712811 [A/G] rs986971 4 65716998 [A/G] rs17085449 4 65736609 [A/G] rs1367337 4 65737833 [A/G] rs17085463 4 65740387 [A/G] rs7674285 4 65750033 [T/C] rs10517902 4 65750373 [T/C] rs1864522 4 65751266 [A/G] rs10023055 4 65755777 [T/C] rs12502234 4 65774664 [T/G] rs12504921 4 65774726 [A/G] rs10008353 4 65776107 [T/G] rs10005825 4 65778213 [A/G] rs6857709 4 65784245 [A/G] NR_033976 LINC02232 Silent rs1372029 4 65791276 [A/G] NR_033976 LINC02232 Silent rs1595974 4 65798746 [T/C] NR_033976 LINC02232 Silent rs968827 4 65801134 [T/C] NR_033976 LINC02232 Silent rs2033944 4 65807695 [T/C] NR_033976 LINC02232 Silent rs17085571 4 65809710 [T/C] NR_033976 LINC02232 Silent rs1372020 4 65817923 [A/C] NR_033976 LINC02232 Silent rs2119436 4 65822976 [T/C] NR_033976 LINC02232 Silent rs6837932 4 65824824 [A/G] NR_033976 LINC02232 Silent rs920508 4 65825862 [T/C] NR_033976 LINC02232 Silent rs11131578 4 65827880 [T/C] NR_033976 LINC02232 Silent rs3943667 4 65831184 [T/C] NR_033976 LINC02232 Silent rs13106164 4 65846651 [A/G] NR_033976 LINC02232 Silent rs10155085 4 65863772 [A/C] NR_033976 LINC02232 Silent rs10011331 4 65871723 [A/G] rs17085702 4 65873197 [T/C] rs6811034 4 65881161 [A/G] rs12186163 4 65886260 [T/C] rs10002389 4 65889825 [A/G] rs9917886 4 65890760 [T/C] rs1440939 4 65895181 [T/C] rs6819203 4 65897053 [T/G] rs1440931 4 65902264 [A/C] rs13152245 4 65903597 [T/C] rs17085830 4 65905019 [A/G] rs991372 4 65905288 [A/G] rs7693800 4 65906658 [T/C] rs9312133 4 65907274 [A/G] rs1348098 4 65934317 [T/C] rs17085861 4 65938412 [A/G] rs10009571 4 65940796 [A/G] rs7668959 4 65945051 [T/G] rs2083551 4 65957836 [T/G] rs996121 4 65960261 [T/C] rs1877116 4 65966308 [T/C] rs329461 4 65979199 [T/C] rs682680 4 65996048 [T/C] rs10013406 4 65996512 [T/C] rs11721592 4 66024351 [T/C] rs371925 4 66058606 [T/C] rs13118169 4 66071716 [T/C] rs1514267 4 66079826 [T/C] rs2349420 4 66083947 [A/G] rs10517923 4 66110165 [A/G] rs13141982 4 66111370 [A/G] rs12504837 4 66117152 [A/G] rs54808 4 66119496 [T/C] rs12499393 4 66126518 [A/G] rs2349720 4 66129033 [A/G] rs1510896 4 66131067 [A/G] rs10008833 4 66136223 [A/G] rs13144461 4 66136680 [A/G] rs7692514 4 66142596 [A/G] rs13150883 4 66146037 [T/C] rs4860646 4 66147444 [T/C] rs7688176 4 66150055 [A/G] rs1376409 4 66167253 [T/G] rs11737511 4 66168773 [T/C] rs13150204 4 66169272 [A/G] rs1160158 4 66173126 [A/C] rs2882226 4 66174910 [T/C] rs1451160 4 66181030 [A/C] rs4860650 4 66187627 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 EXON Silent,Silent,Silent,Silent,Silent rs4860651 4 66188295 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 EXON Silent,Silent,Silent,Silent,Silent rs7356402 4 66191356 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent rs2122722 4 66195601 [A/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent rs7349683 4 66197804 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 EXON Synonymous_G943G,Synonymous_G965G,Synonymous_G897G,Synonymous_G966G,Synonymous_G944G,Synonymous_G966G rs6851828 4 66200170 [A/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs3752774 4 66201634 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs17086092 4 66202345 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs12645455 4 66204540 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs986208 4 66206492 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs2349723 4 66208717 [A/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs1451180 4 66219433 [A/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs13135753 4 66228727 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs28465664 4 66228851 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs36050417 4 66231686 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 EXON Missense_A650T,Missense_A672T,Missense_A604T,Missense_A673T,Missense_A651T,Missense_A673T rs11737618 4 66234071 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs17086137 4 66238145 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs10012882 4 66242549 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs2034537 4 66244369 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs11726788 4 66244695 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs1451173 4 66246438 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4860656 4 66254728 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs10002887 4 66256159 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs1376416 4 66258273 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs10033393 4 66260257 [A/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs6828375 4 66260526 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs2084682 4 66262049 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs1597611 4 66264302 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs2198103 4 66272179 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs13120093 4 66272411 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs17086199 4 66273350 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs17086207 4 66277278 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs12509018 4 66278087 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs2305351 4 66280171 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs10027864 4 66283093 [A/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4349648 4 66289006 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs9986026 4 66292262 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs7672488 4 66294649 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs6831652 4 66300425 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs10013782 4 66304962 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs10003638 4 66305150 [A/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs10007066 4 66306421 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs10006892 4 66308481 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4860665 4 66322437 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs9991256 4 66327854 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4267782 4 66335098 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4425430 4 66340967 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4637457 4 66343670 [T/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs11936348 4 66344954 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs7694306 4 66348548 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4516775 4 66353220 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs11724363 4 66355104 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4337775 4 66359577 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs6815080 4 66362487 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs7654891 4 66374633 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4541571 4 66378192 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs13109328 4 66378789 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4132313 4 66381581 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs7673091 4 66382111 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs13149946 4 66382160 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs7679950 4 66383283 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs11131599 4 66383430 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs7684022 4 66389701 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs11947260 4 66394160 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs10032173 4 66397114 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs10016747 4 66398855 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4860679 4 66401110 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs6551933 4 66403567 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs13134593 4 66411093 [A/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4518304 4 66421666 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs11931601 4 66431909 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs9997603 4 66438114 [T/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs13127631 4 66443874 [T/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs12506403 4 66453438 [A/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs13144830 4 66454374 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs7440592 4 66454906 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs6854088 4 66456030 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs6855605 4 66456092 [A/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4860188 4 66468381 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs11947738 4 66470077 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs13108533 4 66471594 [A/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4320186 4 66483593 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs6831565 4 66488131 [A/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4505878 4 66504490 [T/G] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4565127 4 66526101 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs7655988 4 66527955 [T/C] NM_182472,NM_004439,NM_001318761,NM_001281765,NM_001281766,NM_001281767 EPHA5,EPHA5,EPHA5,EPHA5,EPHA5,EPHA5 Silent,Silent,Silent,Silent,Silent,Silent rs4371664 4 66550619 [T/C] NR_034138 EPHA5-AS1 Silent rs6843972 4 66550952 [A/G] NR_034138 EPHA5-AS1 Silent rs11131613 4 66553425 [A/G] NR_034138 EPHA5-AS1 Silent rs4498177 4 66554209 [T/C] NR_034138 EPHA5-AS1 Silent rs7699335 4 66562536 [A/G] rs9997431 4 66563086 [T/C] rs9784450 4 66565043 [T/G] rs6832704 4 66567056 [A/G] rs13127866 4 66567179 [T/C] rs6851092 4 66568768 [T/G] rs11727254 4 66571857 [A/G] rs4529111 4 66571998 [T/C] rs4860189 4 66576310 [A/G] rs13144348 4 66578235 [A/G] rs4860701 4 66583502 [T/C] rs4629506 4 66583906 [T/C] rs4860703 4 66584922 [T/C] rs6551952 4 66589229 [T/C] rs11131615 4 66596857 [A/G] rs11728136 4 66597539 [T/C] rs6848595 4 66601246 [A/G] rs4241669 4 66610307 [T/C] rs4588513 4 66611856 [T/C] rs10009221 4 66613120 [A/G] rs6813706 4 66615653 [T/C] rs4440279 4 66616643 [T/C] rs7666142 4 66622313 [A/G] rs10031256 4 66622386 [A/G] rs2350336 4 66622515 [A/G] rs17086345 4 66626224 [A/C] rs4368661 4 66626260 [T/C] rs17086349 4 66627407 [T/C] rs17086363 4 66627962 [T/G] rs4382087 4 66628221 [T/C] rs4373205 4 66628728 [T/C] rs2350339 4 66628975 [A/G] rs2882388 4 66629765 [T/G] rs4860707 4 66638816 [T/C] rs2882317 4 66645823 [A/C] rs6845738 4 66655689 [A/C] rs17086372 4 66655790 [A/C] rs1074532 4 66657060 [A/G] rs11131618 4 66658538 [T/G] rs17086389 4 66663257 [T/C] rs4146479 4 66664021 [A/G] rs4484355 4 66681736 [T/C] rs11735605 4 66683829 [T/C] rs2882314 4 66688425 [T/C] rs7660878 4 66689367 [T/G] rs6821937 4 66694519 [T/C] rs10517941 4 66694545 [A/C] rs17082137 4 66697780 [T/C] rs2350064 4 66709201 [T/C] rs10866165 4 66712131 [T/C] rs17755896 4 66712685 [T/C] rs2350070 4 66716472 [A/G] rs4146476 4 66716573 [A/C] rs10517944 4 66729586 [A/G] rs17086487 4 66734932 [A/G] rs6836494 4 66738581 [A/G] rs2350343 4 66745310 [A/G] rs6551968 4 66750577 [A/G] rs17086506 4 66751139 [T/C] rs17086507 4 66751426 [A/C] rs10517949 4 66759828 [T/C] rs2576511 4 66760539 [A/G] rs11930963 4 66763683 [A/G] rs7690714 4 66763742 [T/C] rs12513262 4 66771088 [T/C] rs1897694 4 66774464 [A/G] rs7660970 4 66777240 [T/G] rs7679437 4 66777683 [T/C] rs12505828 4 66779689 [T/C] rs10022875 4 66783098 [A/G] rs10023064 4 66783283 [A/G] rs6825624 4 66786261 [A/G] rs17086628 4 66791167 [A/G] rs1897691 4 66796556 [T/C] rs6815570 4 66797440 [A/G] rs11131630 4 66803361 [A/G] rs11733341 4 66805499 [T/C] rs10517951 4 66811323 [A/G] rs11945164 4 66812771 [A/G] rs17708692 4 66822729 [A/G] rs17086655 4 66826473 [A/C] rs17708914 4 66827845 [A/C] rs2588708 4 66865055 [T/C] rs7683217 4 66881057 [T/C] rs17709448 4 66882613 [T/G] rs13102215 4 66899906 [A/G] rs1979342 4 66911964 [T/C] rs6855976 4 66917610 [A/G] rs2588665 4 66923059 [A/C] rs2588681 4 66949475 [A/G] rs6850299 4 66965155 [T/G] rs13149202 4 66984331 [A/G] rs13110147 4 66991420 [A/G] rs11942020 4 67005499 [T/G] rs1461827 4 67009474 [A/G] rs6551997 4 67012685 [A/G] rs960865 4 67022718 [T/G] rs1459417 4 67033158 [T/C] rs10517955 4 67033505 [A/G] rs2588666 4 67036815 [T/C] rs2611059 4 67041359 [T/C] rs1436 4 67042255 [A/G] rs11725618 4 67053769 [T/C] rs13102033 4 67055090 [A/G] rs3919827 4 67067806 [T/G] rs2061459 4 67069001 [A/G] rs1993644 4 67069599 [A/C] rs2350804 4 67075938 [T/C] rs10028587 4 67078994 [A/C] rs7680820 4 67082181 [A/G] rs7654157 4 67087489 [A/G] rs10011993 4 67093452 [A/C] rs1511282 4 67097186 [A/G] rs6834031 4 67104099 [A/C] rs400524 4 67118667 [A/G] rs450788 4 67124222 [T/C] rs17086929 4 67124441 [A/G] rs535324 4 67125477 [T/G] rs434623 4 67126645 [A/G] rs13140283 4 67131708 [T/C] rs17714933 4 67138858 [T/C] rs17086964 4 67139219 [A/C] rs17086968 4 67139606 [T/C] rs1397755 4 67140834 [A/G] rs12645637 4 67147791 [A/C] rs12642661 4 67169493 [T/C] rs12649988 4 67183218 [T/C] rs17087002 4 67186313 [A/G] rs17087006 4 67188285 [T/G] rs17087008 4 67188696 [A/G] rs10009967 4 67203187 [A/G] rs2942544 4 67210563 [A/G] rs10034030 4 67218350 [A/G] rs13142032 4 67224085 [A/G] rs13127224 4 67227162 [A/C] rs11729723 4 67230762 [A/G] rs1033095 4 67232011 [T/C] rs1511279 4 67234581 [A/G] rs17087075 4 67234740 [A/G] rs11945575 4 67236121 [A/G] rs2942543 4 67237446 [A/G] rs17728252 4 67242685 [T/G] rs6552006 4 67253757 [T/C] rs10517980 4 67257460 [T/C] rs17087127 4 67257909 [T/G] rs1511277 4 67260326 [T/G] rs6823164 4 67262225 [T/C] rs17087146 4 67275267 [A/G] rs17728992 4 67286584 [T/C] rs6838213 4 67287728 [T/C] rs2175431 4 67292325 [T/G] rs4860743 4 67293088 [T/C] rs2009314 4 67300802 [A/G] rs1877517 4 67301594 [A/G] rs1877515 4 67301889 [T/C] rs1996076 4 67311736 [A/G] rs1996074 4 67314393 [A/G] rs9647495 4 67315227 [A/G] rs1512965 4 67334039 [T/C] rs7663168 4 67337614 [T/G] rs11731608 4 67345098 [T/C] rs7669583 4 67345899 [A/G] rs17087196 4 67347879 [A/G] rs4860756 4 67350474 [T/G] rs1398548 4 67358218 [T/C] rs1398547 4 67358778 [A/G] rs1512945 4 67362872 [A/G] rs9312156 4 67377865 [A/C] rs1022126 4 67382811 [A/G] rs7676173 4 67386470 [A/G] rs1983217 4 67388351 [A/G] rs8180319 4 67389529 [T/C] rs10517992 4 67399515 [A/C] rs10517994 4 67400568 [T/C] rs1510740 4 67401602 [A/G] rs17731697 4 67423095 [T/C] rs2203018 4 67424395 [A/G] rs1510742 4 67432445 [T/C] rs1510743 4 67436220 [T/C] rs2882598 4 67438833 [A/G] rs10013019 4 67439729 [T/C] rs10021655 4 67448037 [A/G] rs17087334 4 67449203 [A/G] rs13435376 4 67451127 [A/C] rs17087338 4 67451328 [T/G] rs17732645 4 67453634 [T/C] rs1397470 4 67459961 [A/G] rs4032303 4 67463707 [T/C] rs1510745 4 67468459 [A/C] rs11934386 4 67470362 [T/C] rs4860765 4 67471664 [T/C] rs4860766 4 67471682 [A/G] rs2136822 4 67482764 [T/C] rs1397453 4 67501423 [A/G] rs2203017 4 67507665 [A/G] rs6552022 4 67514485 [A/G] rs4624710 4 67523957 [T/C] rs7695566 4 67525255 [T/C] rs4602541 4 67529651 [T/C] rs4860771 4 67567104 [A/G] rs11733560 4 67572774 [T/C] rs17790467 4 67589776 [A/G] rs713435 4 67594125 [A/C] rs1530759 4 67596504 [T/C] rs10518014 4 67599908 [A/G] rs10518013 4 67600200 [A/G] rs10866173 4 67606895 [T/C] rs7655881 4 67607007 [T/C] rs4860778 4 67612269 [T/C] rs13144587 4 67613272 [A/C] rs9996690 4 67624510 [T/C] rs1375890 4 67630679 [T/C] rs1375885 4 67635469 [A/G] rs6834814 4 67641168 [A/G] rs6842084 4 67642371 [A/C] rs1545429 4 67644546 [A/G] rs11131652 4 67645785 [A/G] rs1450038 4 67654478 [T/C] rs1450036 4 67657239 [T/C] rs7697495 4 67661122 [T/C] rs997185 4 67668580 [T/C] rs1495103 4 67673566 [T/C] rs1353320 4 67677853 [A/G] rs17736022 4 67686485 [A/G] rs10434245 4 67696225 [A/C] rs17087561 4 67705355 [T/C] rs12506243 4 67708427 [A/G] rs10013138 4 67710609 [T/C] rs1450024 4 67716110 [A/G] rs12507395 4 67716733 [T/C] rs12512195 4 67722262 [A/C] rs11726617 4 67733165 [A/G] rs1155865 4 67733857 [A/G] rs1868599 4 67734753 [A/G] rs17799404 4 67741837 [T/G] rs10033533 4 67758299 [A/G] rs9999249 4 67758372 [A/G] rs1481253 4 67759254 [A/G] rs11724395 4 67761636 [A/C] rs7671625 4 67762025 [A/G] rs6818708 4 67762959 [T/C] rs1481245 4 67763820 [A/G] rs1585959 4 67774097 [T/C] rs923994 4 67802992 [A/G] rs11947612 4 67807854 [A/G] rs1390067 4 67808949 [T/C] rs1390066 4 67809075 [A/C] rs9999351 4 67811092 [A/G] rs2164300 4 67813017 [T/C] rs9998536 4 67813997 [A/C] rs10031872 4 67814133 [T/C] rs11938473 4 67815068 [A/G] rs2035366 4 67820174 [T/G] rs2019834 4 67826009 [T/G] rs10518015 4 67828945 [A/C] rs11736089 4 67839637 [T/C] rs12500685 4 67843376 [T/C] rs987811 4 67872428 [A/G] rs17746145 4 67878373 [T/C] rs1435423 4 67884593 [A/G] rs13141210 4 67891641 [T/C] rs12506221 4 67899235 [T/G] rs787361 4 67904595 [T/C] rs787363 4 67906156 [A/G] rs11940944 4 67910084 [T/C] rs787370 4 67911404 [T/G] rs12645870 4 67921630 [A/G] rs12186186 4 67925197 [A/C] rs17087942 4 67926138 [A/C] rs1425664 4 67939089 [A/G] rs1425653 4 67954517 [T/C] rs10010944 4 67958264 [T/C] rs10018066 4 67961296 [A/C] rs1425654 4 67965487 [A/G] rs17088003 4 67972601 [A/G] rs10866177 4 67994618 [T/C] rs6818650 4 68006895 [A/G] rs10518020 4 68007388 [A/G] rs11131679 4 68007509 [A/G] rs933830 4 68019294 [A/C] rs730934 4 68024153 [T/C] rs1346075 4 68028922 [T/G] rs7669686 4 68038559 [A/G] rs28534578 4 68039482 [T/C] rs7690543 4 68056613 [T/C] rs1425660 4 68058793 [A/G] rs6854985 4 68059850 [A/G] rs6814715 4 68060773 [A/C] rs6815091 4 68061633 [A/G] rs10518025 4 68064440 [T/C] rs1425658 4 68064531 [A/C] rs9312170 4 68065150 [T/C] rs10518026 4 68065358 [T/C] rs11942221 4 68067034 [T/G] rs12639670 4 68069022 [A/G] rs17088117 4 68070195 [A/C] rs13151209 4 68071781 [A/G] rs1549448 4 68074583 [A/G] rs6814470 4 68075795 [T/C] rs1425655 4 68085262 [A/C] rs6819869 4 68088235 [A/G] rs4860238 4 68093400 [A/G] rs4639131 4 68095870 [T/C] rs1866784 4 68101830 [T/C] rs4860821 4 68101946 [T/C] rs17766472 4 68102182 [T/C] rs4133270 4 68104490 [T/C] rs11131687 4 68106106 [A/G] rs10005602 4 68113850 [T/G] rs17088195 4 68114583 [T/G] rs1158408 4 68116539 [A/G] rs4860822 4 68117200 [T/C] rs2218192 4 68123521 [A/G] rs1440556 4 68123616 [T/G] rs1371864 4 68127826 [A/C] rs17767450 4 68132509 [A/G] rs1946918 4 68154530 [T/C] rs17818614 4 68155364 [A/G] rs11724259 4 68159587 [T/C] rs6852744 4 68159785 [A/G] rs28373882 4 68167336 [T/C] rs1440559 4 68174701 [A/G] rs9985687 4 68176106 [T/G] rs11929914 4 68177499 [T/C] rs12504640 4 68183082 [T/C] rs1899130 4 68186030 [T/C] rs1371863 4 68192816 [A/G] rs1348058 4 68193125 [T/G] rs746877 4 68198578 [A/C] rs17088281 4 68199483 [A/G] rs1946920 4 68207449 [A/G] rs1497431 4 68215003 [T/G] rs356310 4 68222094 [T/C] rs10518036 4 68222294 [A/G] rs356306 4 68224591 [A/G] rs356335 4 68228744 [T/C] rs10008670 4 68237962 [T/C] rs6824881 4 68241071 [T/G] rs920482 4 68241081 [A/G] rs7669658 4 68250856 [T/C] rs13103397 4 68252674 [A/G] rs356343 4 68253127 [T/C] rs1497427 4 68262262 [T/C] rs3932174 4 68263831 [T/G] rs17428139 4 68267437 [T/C] rs3935662 4 68269400 [T/C] rs4860843 4 68289606 [T/C] rs7696609 4 68293285 [T/G] rs1874633 4 68337435 [A/G] NM_001362481,NR_155754,NM_001812 CENPC,CENPC,CENPC EXON Silent,Silent,Silent rs17088445 4 68369968 [T/C] NM_001362481,NR_155754,NM_001812 CENPC,CENPC,CENPC Silent,Silent,Silent rs355466 4 68377472 [A/G] NM_001362481,NR_155754,NM_001812 CENPC,CENPC,CENPC Silent,Silent,Silent rs355462 4 68379299 [A/G] NM_001362481,NR_155754,NM_001812 CENPC,CENPC,CENPC Silent,Silent,Silent rs1056787 4 68380070 [T/C] NM_001362481,NR_155754,NM_001812 CENPC,CENPC,CENPC EXON Missense_G389D,Silent,Missense_G389D rs173317 4 68381367 [T/C] NM_001362481,NR_155754,NM_001812 CENPC,CENPC,CENPC Silent,Silent,Silent rs13104130 4 68385372 [T/C] NM_001362481,NR_155754,NM_001812 CENPC,CENPC,CENPC Silent,Silent,Silent rs17625547 4 68410009 [T/C] NM_001362481,NR_155754,NM_001812 CENPC,CENPC,CENPC Silent,Silent,Silent rs957582 4 68412148 [A/C] rs13119483 4 68415286 [T/C] rs7700004 4 68419485 [T/C] rs7681780 4 68428733 [T/G] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs7682206 4 68428980 [T/G] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs13111555 4 68436883 [T/C] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs2306810 4 68441091 [T/C] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs13149974 4 68442968 [A/G] NM_001317769,NM_012108 STAP1,STAP1 EXON Synonymous_T118T,Synonymous_T118T rs17088473 4 68443308 [T/G] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs13131164 4 68444102 [A/C] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs3775866 4 68444180 [A/G] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs11725922 4 68444192 [A/G] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs12507679 4 68447040 [T/C] NM_001317769,NM_012108 STAP1,STAP1 EXON Synonymous_N127N,Synonymous_N127N rs2242331 4 68447200 [A/G] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs2242330 4 68447249 [A/G] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs2087176 4 68450302 [T/C] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs17632290 4 68453189 [T/C] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs10000695 4 68457695 [A/G] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs7681638 4 68458808 [A/G] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs6830199 4 68460255 [T/C] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs900791 4 68470455 [T/C] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs354883 4 68470522 [T/C] NM_001317769,NM_012108 STAP1,STAP1 Silent,Silent rs1054593 4 68472428 [T/C] NM_001317769,NM_012108 STAP1,STAP1 EXON Silent,Silent rs354885 4 68472604 [T/C] NM_001317769,NM_012108 STAP1,STAP1 EXON Silent,Silent rs4860262 4 68480525 [T/C] rs1048447 4 68483472 [A/G] NM_018227 UBA6 EXON Silent rs3796715 4 68493076 [T/C] NM_018227 UBA6 Silent rs354872 4 68515155 [T/C] NM_018227 UBA6 Silent rs10006851 4 68524526 [A/G] NM_018227 UBA6 Silent rs1017878 4 68536679 [T/G] NM_018227 UBA6 Silent rs2170872 4 68536966 [T/C] NM_018227 UBA6 Silent rs9994341 4 68559627 [T/C] NM_018227 UBA6 Silent rs17572160 4 68562365 [A/G] NM_018227 UBA6 EXON Synonymous_Y44Y rs2630489 4 68591252 [A/G] rs2711144 4 68598694 [A/C] rs1843593 4 68598998 [T/C] rs1038427 4 68603702 [T/C] NM_000406,NM_001012763 GNRHR,GNRHR EXON Silent,Silent rs3811842 4 68609746 [A/G] NM_000406,NM_001012763 GNRHR,GNRHR Silent,Silent rs17573883 4 68613969 [T/C] NM_000406,NM_001012763 GNRHR,GNRHR Silent,Silent rs974483 4 68615500 [A/G] NM_000406,NM_001012763 GNRHR,GNRHR Silent,Silent rs972072 4 68617365 [T/G] NM_000406,NM_001012763 GNRHR,GNRHR Silent,Silent rs6828922 4 68618451 [T/C] NM_000406,NM_001012763 GNRHR,GNRHR Silent,Silent rs4986942 4 68619601 [A/G] NM_000406,NM_001012763 GNRHR,GNRHR EXON Synonymous_S151S,Synonymous_S151S rs2627260 4 68620277 [T/C] NM_000406,NM_001012763 GNRHR,GNRHR EXON Silent,Silent rs6552113 4 68620957 [T/C] NM_000406,NM_001012763 GNRHR,GNRHR EXON Silent,Silent rs10005857 4 68624442 [A/G] rs13102739 4 68631416 [T/C] rs1484188 4 68639112 [A/G] rs1155222 4 68650694 [T/C] rs9312188 4 68653189 [T/C] rs2582358 4 68654739 [T/C] rs6552116 4 68672416 [A/G] rs4504308 4 68673583 [A/G] rs6552123 4 68686507 [A/G] rs13142201 4 68697199 [T/C] NM_004262 TMPRSS11D Silent rs1371928 4 68701771 [T/C] NM_004262 TMPRSS11D Silent rs10022223 4 68706863 [A/G] NM_004262 TMPRSS11D Silent rs1371927 4 68715140 [A/C] NM_004262 TMPRSS11D Silent rs718591 4 68716465 [A/G] NM_004262 TMPRSS11D Silent rs1872581 4 68718486 [T/C] NM_004262 TMPRSS11D Silent rs1348079 4 68718552 [T/C] NM_004262 TMPRSS11D Silent rs1542664 4 68725776 [T/C] NM_004262 TMPRSS11D Silent rs11131729 4 68727562 [A/G] NM_004262 TMPRSS11D Silent rs17577246 4 68737593 [A/G] NM_004262 TMPRSS11D Silent rs17088739 4 68737644 [A/C] NM_004262 TMPRSS11D Silent rs6811522 4 68738544 [A/G] NM_004262 TMPRSS11D Silent rs11945715 4 68747496 [T/C] NM_004262 TMPRSS11D Silent rs960994 4 68750409 [A/G] rs1440743 4 68751635 [T/G] rs959636 4 68763794 [A/G] rs12651048 4 68765277 [A/G] rs2165365 4 68773898 [T/C] rs1440740 4 68775707 [A/G] rs353172 4 68780041 [A/G] NM_001114387,NM_182606 TMPRSS11A,TMPRSS11A Silent,Silent rs6839279 4 68789778 [T/G] NM_001114387,NM_182606 TMPRSS11A,TMPRSS11A Silent,Silent rs353158 4 68791400 [A/G] NM_001114387,NM_182606 TMPRSS11A,TMPRSS11A Silent,Silent rs13435828 4 68795290 [A/G] NM_001114387,NM_182606 TMPRSS11A,TMPRSS11A Silent,Silent rs6849403 4 68806909 [T/C] NM_001114387,NM_182606 TMPRSS11A,TMPRSS11A Silent,Silent rs168482 4 68808967 [T/C] NM_001114387,NM_182606 TMPRSS11A,TMPRSS11A Silent,Silent rs1370840 4 68810246 [A/G] NM_001114387,NM_182606 TMPRSS11A,TMPRSS11A EXON Synonymous_T81T,Synonymous_T81T rs12642405 4 68811137 [A/C] NM_001114387,NM_182606 TMPRSS11A,TMPRSS11A Silent,Silent rs11930532 4 68812283 [T/C] NM_001114387,NM_182606 TMPRSS11A,TMPRSS11A EXON Synonymous_V6V,Synonymous_V6V rs2319691 4 68814218 [A/G] NM_001114387,NM_182606 TMPRSS11A,TMPRSS11A Silent,Silent rs1561385 4 68821282 [A/G] NM_001114387,NM_182606 TMPRSS11A,TMPRSS11A Silent,Silent rs727534 4 68822218 [A/G] NM_001114387,NM_182606 TMPRSS11A,TMPRSS11A Silent,Silent rs6552134 4 68829207 [A/G] NM_001114387,NM_182606 TMPRSS11A,TMPRSS11A EXON Silent,Silent rs11947613 4 68829223 [A/G] NM_001114387,NM_182606 TMPRSS11A,TMPRSS11A EXON Silent,Silent rs17088850 4 68829603 [A/G] rs1866325 4 68832165 [T/C] rs4362874 4 68873083 [A/G] rs6826271 4 68874618 [A/G] rs3860694 4 68877522 [A/C] rs7661514 4 68882510 [T/G] rs3910547 4 68890221 [A/C] rs4324597 4 68899971 [T/C] rs2164937 4 68911041 [T/C] rs6817194 4 68913256 [A/C] rs6851972 4 68914769 [A/G] rs13112221 4 68915798 [T/G] rs10018943 4 68919617 [A/G] NM_207407,NR_046116 TMPRSS11F,LOC550113 EXON Silent,Silent rs1438445 4 68920638 [A/G] NM_207407,NR_046116 TMPRSS11F,LOC550113 Silent,Silent rs2164935 4 68921021 [A/C] NM_207407,NR_046116 TMPRSS11F,LOC550113 Silent,Silent rs1370828 4 68925617 [T/C] NM_207407,NR_046116 TMPRSS11F,LOC550113 Silent,Silent rs1898644 4 68933046 [A/G] NM_207407,NR_046116 TMPRSS11F,LOC550113 Silent,Silent rs1079449 4 68934252 [A/C] NM_207407,NR_046116 TMPRSS11F,LOC550113 Silent,Silent rs10004522 4 68934306 [A/G] NM_207407,NR_046116 TMPRSS11F,LOC550113 Silent,Silent rs1438391 4 68938185 [T/C] NM_207407,NR_046116 TMPRSS11F,LOC550113 EXON Missense_D124N,Silent rs1370830 4 68940208 [A/G] NM_207407 TMPRSS11F Silent rs6552145 4 68942150 [T/C] NM_207407 TMPRSS11F Silent rs4860900 4 68949916 [T/C] NM_207407 TMPRSS11F Silent rs1370834 4 68956040 [A/G] NM_207407 TMPRSS11F Silent rs17089042 4 68956856 [A/G] NM_207407 TMPRSS11F Silent rs7665380 4 68958290 [T/C] NM_207407 TMPRSS11F Silent rs966827 4 68962223 [A/G] NM_207407 TMPRSS11F Silent rs7676484 4 68963631 [A/G] NM_207407 TMPRSS11F Silent rs10019959 4 68982038 [T/G] NM_207407 TMPRSS11F Silent rs10031258 4 68990767 [T/C] NM_207407 TMPRSS11F Silent rs10030708 4 68995529 [T/C] NM_207407 TMPRSS11F EXON Missense_A4T rs6819568 4 69013001 [T/C] rs1320265 4 69019690 [T/C] rs10000160 4 69033099 [A/G] rs11931973 4 69049719 [A/C] NR_015446 FTLP10 Silent rs17590869 4 69050703 [A/G] NR_015446,NR_104048 FTLP10,TMPRSS11BNL Silent,Silent rs6845487 4 69052317 [T/C] NR_015446,NR_104048 FTLP10,TMPRSS11BNL Silent,Silent rs10008636 4 69083563 [T/C] NR_104048 TMPRSS11BNL Silent rs10015034 4 69085553 [A/C] rs7434495 4 69087267 [A/G] rs4860919 4 69091168 [T/C] rs2319796 4 69094575 [T/G] NM_182502 TMPRSS11B EXON Missense_D325A rs12331141 4 69095197 [T/C] NM_182502 TMPRSS11B EXON Missense_I242V rs6552175 4 69098006 [T/C] NM_182502 TMPRSS11B Silent rs10018067 4 69098115 [A/G] NM_182502 TMPRSS11B EXON Synonymous_S163S rs9994462 4 69103997 [T/C] NM_182502 TMPRSS11B Silent rs10009400 4 69120079 [A/G] rs6840820 4 69126345 [T/C] rs11933242 4 69132978 [A/G] rs7691074 4 69138386 [A/G] rs7670560 4 69138643 [A/G] rs1996598 4 69141870 [T/C] rs10866204 4 69149571 [T/C] rs7678448 4 69151046 [T/C] rs7659406 4 69155649 [T/C] rs1962172 4 69160724 [A/G] rs939207 4 69167671 [T/C] rs1730875 4 69174057 [T/C] rs6831889 4 69175616 [T/C] rs1715081 4 69176798 [T/C] NM_001330698,NM_133370,NM_001031732 YTHDC1,YTHDC1,YTHDC1 EXON Silent,Silent,Silent rs17592288 4 69177138 [A/C] NM_001330698,NM_133370,NM_001031732 YTHDC1,YTHDC1,YTHDC1 EXON Silent,Silent,Silent rs2293595 4 69178920 [T/C] NM_001330698,NM_133370,NM_001031732 YTHDC1,YTHDC1,YTHDC1 EXON Silent,Silent,Silent rs10027564 4 69185291 [T/C] NM_001330698,NM_133370,NM_001031732 YTHDC1,YTHDC1,YTHDC1 Silent,Silent,Silent rs13130895 4 69199987 [T/C] NM_001330698,NM_133370,NM_001031732 YTHDC1,YTHDC1,YTHDC1 Silent,Silent,Silent rs3813832 4 69203080 [T/C] NM_001330698,NM_133370,NM_001031732 YTHDC1,YTHDC1,YTHDC1 EXON Missense_H183R,Missense_H183R,Missense_H183R rs17592868 4 69214926 [T/C] NM_001330698,NM_133370,NM_001031732 YTHDC1,YTHDC1,YTHDC1 Silent,Silent,Silent rs7666993 4 69215034 [A/G] NM_001330698,NM_133370,NM_001031732 YTHDC1,YTHDC1,YTHDC1 Silent,Silent,Silent rs4860928 4 69219049 [A/G] rs11932381 4 69220383 [T/C] rs6829979 4 69221691 [A/G] rs17652284 4 69223057 [T/G] rs34527218 4 69244539 [T/G] rs35303534 4 69250882 [T/C] rs35377534 4 69252261 [A/G] rs35096223 4 69259223 [A/G] rs4860941 4 69280975 [A/G] rs11722296 4 69282119 [A/C] rs4860296 4 69283448 [T/C] rs2708699 4 69341037 [T/C] NM_014058 TMPRSS11E Silent rs1454247 4 69341579 [T/C] NM_014058 TMPRSS11E Silent rs2708697 4 69349034 [T/C] NM_014058 TMPRSS11E Silent rs34253002 4 69353863 [A/G] NM_014058 TMPRSS11E Silent rs35084682 4 69363682 [A/G] rs2603152 4 69367074 [T/C] rs11938019 4 69425362 [T/C] NM_001077 UGT2B17 Silent rs6857249 4 69434902 [A/G] rs36069550 4 69500664 [T/C] rs4348161 4 69505100 [T/C] rs4148271 4 69512637 [A/T] NM_001076 UGT2B15 EXON Silent rs293466 4 69566703 [T/C] rs34778440 4 69575707 [T/C] rs17221784 4 69577395 [T/C] rs293433 4 69590353 [A/G] rs293431 4 69590669 [A/G] rs293429 4 69591612 [T/C] rs376360 4 69595144 [A/C] rs4694270 4 69598506 [T/C] rs293408 4 69601124 [T/C] rs407182 4 69606943 [A/G] rs397678 4 69611505 [T/C] rs403552 4 69613030 [T/C] rs11734565 4 69625607 [T/C] rs4235087 4 69627526 [T/G] rs1513557 4 69630828 [A/G] rs9993883 4 69632909 [A/G] rs11726899 4 69646009 [T/C] rs294755 4 69665970 [A/G] rs11737672 4 69671302 [T/C] rs294768 4 69673775 [A/C] rs4694340 4 69676142 [A/G] rs11729424 4 69678679 [T/C] rs12644440 4 69679570 [A/C] rs294777 4 69682471 [A/G] NM_001144767,NM_001075,NM_001290091 UGT2B10,UGT2B10,UGT2B10 Silent,Silent,Silent rs844342 4 69684121 [T/G] NM_001144767,NM_001075,NM_001290091 UGT2B10,UGT2B10,UGT2B10 Silent,Silent,Silent rs9917967 4 69684218 [A/G] NM_001144767,NM_001075,NM_001290091 UGT2B10,UGT2B10,UGT2B10 Silent,Silent,Silent rs835311 4 69684548 [G/C] NM_001144767,NM_001075,NM_001290091 UGT2B10,UGT2B10,UGT2B10 Silent,Silent,Silent rs835317 4 69686221 [T/G] NM_001144767,NM_001075,NM_001290091 UGT2B10,UGT2B10,UGT2B10 Silent,Silent,Silent rs835319 4 69686425 [A/G] NM_001144767,NM_001075,NM_001290091 UGT2B10,UGT2B10,UGT2B10 Silent,Silent,Silent rs13114078 4 69686809 [A/C] NM_001144767,NM_001075,NM_001290091 UGT2B10,UGT2B10,UGT2B10 Silent,Silent,Silent rs294772 4 69694941 [A/G] NM_001144767,NM_001075,NM_001290091 UGT2B10,UGT2B10,UGT2B10 Silent,Silent,Silent rs11249509 4 69695310 [A/G] NM_001144767,NM_001075,NM_001290091 UGT2B10,UGT2B10,UGT2B10 Silent,Silent,Silent rs7662046 4 69697795 [T/C] rs11737566 4 69701067 [T/G] rs11737644 4 69701338 [T/C] rs1379809 4 69703527 [A/G] rs6843220 4 69706273 [T/C] rs9996074 4 69708443 [T/G] rs1841043 4 69708718 [A/G] rs1841046 4 69717920 [A/G] rs6600855 4 69725006 [T/C] rs7674919 4 69727682 [A/G] rs11931829 4 69732974 [T/C] rs12500933 4 69736745 [T/C] rs11936760 4 69739064 [T/C] rs752209 4 69739572 [A/G] rs1841037 4 69749311 [T/C] rs17146961 4 69749788 [A/G] rs11724856 4 69752468 [T/C] rs7678798 4 69762953 [T/C] rs12651295 4 69771935 [A/C] rs17146976 4 69774609 [A/G] rs7672933 4 69782124 [T/C] rs10019843 4 69786431 [T/C] rs12648504 4 69787683 [T/C] rs17147006 4 69790343 [A/G] rs4412056 4 69791979 [A/G] rs17605102 4 69818151 [T/C] rs2125306 4 69819484 [T/C] rs1824264 4 69822928 [T/C] rs10027817 4 69829222 [A/G] rs3966085 4 69830542 [A/G] rs1458241 4 69830871 [T/C] rs3886642 4 69833007 [T/C] rs12650968 4 69833099 [T/C] rs6818594 4 69850452 [T/C] rs4590113 4 69853849 [A/G] rs4694490 4 69859702 [T/C] rs7678207 4 69860688 [T/C] rs1841050 4 69862775 [T/C] rs2018024 4 69862918 [A/G] rs4576082 4 69883503 [A/G] NM_001290091,NM_001075,NM_001144767 UGT2B10,UGT2B10,UGT2B10 Silent,Silent,Silent rs4296738 4 69893704 [A/G] rs4235108 4 69893854 [A/G] rs13147648 4 69901663 [T/C] rs4299666 4 69907597 [A/G] rs7438808 4 69916384 [T/G] rs6833862 4 69923096 [T/C] NM_001349568 UGT2B7 Silent rs7662632 4 69927974 [T/C] NM_001349568 UGT2B7 Silent rs9991142 4 69932587 [T/C] NM_001349568 UGT2B7 Silent rs4694169 4 69954151 [T/C] NM_001349568 UGT2B7 Silent rs6600876 4 69956930 [T/G] NM_001349568 UGT2B7 Silent rs11940316 4 69961127 [T/C] NM_001349568 UGT2B7 Silent rs7438135 4 69961339 [A/G] NM_001349568 UGT2B7 Silent rs7662029 4 69961912 [A/G] NM_001349568 UGT2B7 Silent rs7668258 4 69962078 [T/C] NM_001349568 UGT2B7 Silent rs7668282 4 69962114 [T/C] NM_001349568 UGT2B7 Silent rs7441774 4 69964554 [A/G] NM_001349568,NM_001074,NM_001330719 UGT2B7,UGT2B7,UGT2B7 Silent,Silent,Silent rs4293848 4 69965502 [T/C] NM_001349568,NM_001074,NM_001330719 UGT2B7,UGT2B7,UGT2B7 Silent,Silent,Silent rs12506962 4 69966024 [A/G] NM_001349568,NM_001074,NM_001330719 UGT2B7,UGT2B7,UGT2B7 Silent,Silent,Silent rs12512526 4 69966418 [T/C] NM_001349568,NM_001074,NM_001330719 UGT2B7,UGT2B7,UGT2B7 Silent,Silent,Silent rs7439152 4 69969006 [T/G] NM_001349568,NM_001074,NM_001330719 UGT2B7,UGT2B7,UGT2B7 Silent,Silent,Silent rs6858558 4 69969543 [T/C] NM_001349568,NM_001074,NM_001330719 UGT2B7,UGT2B7,UGT2B7 Silent,Silent,Silent rs10028494 4 69970937 [A/C] NM_001349568,NM_001074,NM_001330719 UGT2B7,UGT2B7,UGT2B7 Silent,Silent,Silent rs7435335 4 69971335 [A/G] NM_001349568,NM_001074,NM_001330719 UGT2B7,UGT2B7,UGT2B7 Silent,Silent,Silent rs6600891 4 69971596 [T/C] NM_001349568,NM_001074,NM_001330719 UGT2B7,UGT2B7,UGT2B7 Silent,Silent,Silent rs12513195 4 69972086 [T/G] NM_001349568,NM_001074,NM_001330719 UGT2B7,UGT2B7,UGT2B7 Silent,Silent,Silent rs4356975 4 69972463 [T/C] NM_001349568,NM_001074,NM_001330719 UGT2B7,UGT2B7,UGT2B7 Silent,Silent,Silent rs4521414 4 69973525 [A/C] NM_001349568,NM_001074,NM_001330719 UGT2B7,UGT2B7,UGT2B7 Silent,Silent,Silent rs6600897 4 69987249 [A/C] rs4318715 4 69995509 [A/C] rs11249529 4 69997633 [A/C] rs6822259 4 70003963 [T/C] rs4694181 4 70004010 [A/C] rs4415024 4 70005443 [T/C] rs6600900 4 70013537 [A/G] rs4273535 4 70019933 [T/G] rs4593203 4 70031620 [A/G] rs10016939 4 70057009 [A/C] NR_136191 LOC105377267 Silent rs6825376 4 70057930 [A/G] NR_136191 LOC105377267 Silent rs4342251 4 70058114 [T/C] NR_136191 LOC105377267 Silent rs4326078 4 70058335 [A/C] NR_136191 LOC105377267 Silent rs7681221 4 70059088 [T/C] NR_136191 LOC105377267 Silent rs4694199 4 70059980 [A/G] NR_136191 LOC105377267 Silent rs13123057 4 70061403 [T/G] NR_136191 LOC105377267 EXON Silent rs6830737 4 70061467 [T/G] NR_136191 LOC105377267 EXON Silent rs7672567 4 70062986 [T/C] NR_136191 LOC105377267 Silent rs7660248 4 70066719 [T/G] NR_136191,NM_001073 LOC105377267,UGT2B11 Silent,Silent rs7436729 4 70070608 [A/C] NR_136191,NM_001073 LOC105377267,UGT2B11 Silent,Silent rs4463131 4 70081277 [A/G] NR_136191 LOC105377267 EXON Silent rs6817250 4 70088601 [T/C] rs11939111 4 70115470 [T/G] rs6830865 4 70120699 [T/C] rs4305588 4 70142792 [A/C] rs4569811 4 70158177 [A/C] NM_053039,NM_001207004 UGT2B28,UGT2B28 Silent,Silent rs7693378 4 70234419 [A/C] rs12505338 4 70255961 [A/G] rs12506196 4 70261746 [T/C] rs17606521 4 70265637 [T/G] rs4694733 4 70266213 [T/G] rs12509072 4 70274557 [A/G] rs2736509 4 70287303 [T/G] rs2254718 4 70288522 [A/G] rs2736488 4 70297879 [T/C] rs2736486 4 70299686 [T/C] rs6600933 4 70310691 [A/G] rs7670842 4 70311222 [T/C] rs1845545 4 70314776 [A/G] rs12649644 4 70320823 [T/C] rs12505081 4 70321293 [A/G] rs4694743 4 70324048 [A/G] rs2736467 4 70325709 [A/G] rs1353280 4 70328040 [T/C] rs10031344 4 70328958 [T/C] rs10518060 4 70330250 [T/C] rs2736520 4 70336172 [T/C] rs903446 4 70336501 [A/G] rs1569344 4 70341392 [A/C] rs1569343 4 70341463 [T/G] rs1569342 4 70341550 [A/G] rs2736445 4 70345608 [A/G] rs2736446 4 70345669 [A/G] rs1131878 4 70345904 [T/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 EXON Silent,Silent,Silent rs1966151 4 70346127 [A/G] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 EXON Silent,Silent,Silent rs1389930 4 70347172 [A/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs13114834 4 70349778 [A/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs4557343 4 70350006 [T/G] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs11249442 4 70350357 [A/G] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs12645716 4 70350467 [T/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs10010875 4 70350645 [A/G] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs324408 4 70352690 [A/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs1908406 4 70353258 [C/G] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs2013573 4 70354478 [T/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs2013562 4 70354575 [T/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs1845557 4 70354794 [T/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs13111134 4 70354811 [A/G] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs1845555 4 70355211 [T/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 EXON Synonymous_T180T,Synonymous_T316T,Synonymous_T316T rs3822179 4 70356195 [A/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs6833511 4 70356294 [T/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs324405 4 70356515 [A/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs13139888 4 70357876 [T/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs1494802 4 70357901 [T/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs17671289 4 70358845 [T/G] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs13145834 4 70359068 [A/G] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs983988 4 70359346 [T/C] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs7441743 4 70359694 [A/G] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs1821190 4 70360197 [T/G] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs17614939 4 70360229 [A/G] NM_001297616,NM_001297615,NM_021139 UGT2B4,UGT2B4,UGT2B4 Silent,Silent,Silent rs2736442 4 70362742 [A/G] NM_001297616 UGT2B4 Silent rs7657880 4 70371555 [A/G] NM_001297616 UGT2B4 Silent rs10461367 4 70394123 [A/G] rs13151633 4 70395452 [A/G] rs6825148 4 70405837 [T/C] rs13119100 4 70406812 [A/G] rs12502677 4 70438197 [A/C] rs17616972 4 70438763 [T/C] rs4463132 4 70443083 [A/G] rs11939113 4 70448535 [T/G] rs7687676 4 70449652 [A/G] rs4333255 4 70452288 [T/C] rs11929908 4 70453516 [T/C] rs11929943 4 70453638 [T/C] rs4148311 4 70454991 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 EXON Silent,Silent,Silent,Silent,Silent,Silent rs2288741 4 70455478 [T/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs2288740 4 70455579 [G/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs1438537 4 70455650 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs4148309 4 70455884 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs4148308 4 70456186 [T/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs4148307 4 70457556 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs1432327 4 70457877 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs1432324 4 70458182 [A/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs4148304 4 70460328 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 EXON Missense_V347I,Missense_V391I,Missense_V400I,Missense_V356I,Missense_V391I,Missense_V557I rs11732515 4 70461111 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs1158439 4 70462621 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs1821185 4 70462669 [T/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs2010207 4 70462803 [T/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs1319811 4 70462893 [A/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs1432316 4 70463600 [T/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs1432315 4 70463662 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs3775783 4 70463854 [A/T] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs3822178 4 70464413 [A/T] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs4148299 4 70464511 [G/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs4148298 4 70464701 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs3775782 4 70465153 [T/A] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs10023782 4 70465584 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs10033801 4 70465626 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs10033879 4 70465737 [T/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs1432313 4 70466810 [T/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs1036160 4 70467109 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs6832167 4 70474310 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs4148295 4 70475866 [A/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs324313 4 70476136 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs1432336 4 70476595 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs6852329 4 70477005 [T/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs11728546 4 70477328 [T/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs4148293 4 70477690 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs6600793 4 70477984 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs6600794 4 70478169 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs6848997 4 70478971 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs10011912 4 70480327 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs4694222 4 70480926 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs7670819 4 70481880 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs7676249 4 70482097 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs2033801 4 70482416 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs4148291 4 70483323 [A/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs4148288 4 70484250 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs6824830 4 70485627 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs6855271 4 70485663 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs2116564 4 70487120 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs11249453 4 70488786 [T/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs10903210 4 70488849 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs13119853 4 70488979 [A/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs324309 4 70491234 [T/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs1835829 4 70491891 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs324310 4 70491922 [A/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs10001991 4 70491970 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs10023877 4 70492055 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs10022954 4 70494631 [T/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs6854350 4 70494901 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs17674565 4 70494933 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs10011630 4 70494984 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs17618178 4 70495961 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs17674648 4 70496262 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs7665571 4 70497601 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs7699881 4 70498148 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs17147521 4 70498165 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs11249454 4 70499234 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs6824954 4 70500830 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs7686386 4 70501756 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs7681367 4 70501787 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs7662309 4 70501980 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs7692074 4 70502386 [T/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs17618520 4 70502779 [A/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs10518063 4 70503978 [C/G] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs9992698 4 70504313 [T/C] NM_001301239,NM_001252275,NM_001105677,NM_001301233,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A2,UGT2A2,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent,Silent,Silent rs17147532 4 70505904 [T/C] NM_001301239,NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent rs11936310 4 70506120 [A/G] NM_001301239,NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent rs988672 4 70506518 [T/C] NM_001301239,NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent rs988671 4 70506828 [A/G] NM_001301239,NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent rs17147542 4 70507156 [T/G] NM_001301239,NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent rs2331685 4 70507794 [T/C] NM_001301239,NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent rs4148285 4 70509457 [T/A] NM_001301239,NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent rs4148284 4 70509530 [A/C] NM_001301239,NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent rs4148282 4 70511200 [A/G] NM_001301239,NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent rs1560605 4 70511427 [G/C] NM_001301239,NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent,Silent rs1347046 4 70513139 [T/C] NM_001301239,NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1,UGT2A1 EXON Missense_R75K,Missense_R75K,Missense_R75K,Missense_R75K rs1432329 4 70513710 [T/C] NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent rs4148279 4 70514358 [T/C] NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent rs4148276 4 70514903 [G/C] NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent rs4148275 4 70515025 [T/G] NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent rs10000435 4 70516671 [T/C] NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent rs7668703 4 70517952 [T/C] NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent rs979363 4 70518712 [T/C] NM_001252275,NM_006798,NM_001252274 UGT2A1,UGT2A1,UGT2A1 Silent,Silent,Silent rs4395582 4 70519417 [A/G] rs10033854 4 70519904 [A/G] rs10518065 4 70520597 [A/G] rs13134357 4 70520830 [T/C] rs6810459 4 70521159 [T/C] rs11937993 4 70521514 [A/G] rs7671041 4 70521620 [A/G] rs1347047 4 70521755 [T/C] rs1948828 4 70540370 [T/G] rs11249456 4 70540563 [T/C] rs2221366 4 70557072 [A/G] rs1587765 4 70567104 [A/G] rs17681469 4 70570637 [A/G] rs4694242 4 70584038 [A/G] rs7696239 4 70586610 [A/G] rs17620185 4 70587338 [A/G] rs2292090 4 70588309 [T/C] rs9685617 4 70588741 [T/G] rs4149419 4 70592242 [T/G] rs4149418 4 70592360 [A/C] rs4149417 4 70592638 [A/C] rs2292092 4 70592790 [T/G] NM_014465 SULT1B1 EXON Silent rs11569729 4 70592915 [A/G] NM_014465 SULT1B1 EXON Missense_T261M rs3756139 4 70593547 [A/G] NM_014465 SULT1B1 Silent rs7668109 4 70594830 [A/G] NM_014465 SULT1B1 Silent rs3775781 4 70595637 [T/C] NM_014465 SULT1B1 Silent rs11569726 4 70596186 [T/C] NM_014465 SULT1B1 Silent rs4694031 4 70596727 [T/C] NM_014465 SULT1B1 Silent rs6817798 4 70597081 [A/G] NM_014465 SULT1B1 Silent rs3775780 4 70597380 [T/C] NM_014465 SULT1B1 Silent rs1394039 4 70598066 [T/C] NM_014465 SULT1B1 Silent rs1847366 4 70599073 [T/C] NM_014465 SULT1B1 Silent rs13106114 4 70599164 [A/T] NM_014465 SULT1B1 EXON Synonymous_P188P rs13152058 4 70599187 [A/C] NM_014465 SULT1B1 EXON Missense_W181G rs13106169 4 70599237 [T/G] NM_014465 SULT1B1 Silent rs1394038 4 70599386 [T/C] NM_014465 SULT1B1 Silent rs13152541 4 70599415 [A/C] NM_014465 SULT1B1 Silent rs13133166 4 70600199 [C/G] NM_014465 SULT1B1 Silent rs17626012 4 70600256 [T/C] NM_014465 SULT1B1 Silent rs1847365 4 70601192 [A/C] NM_014465 SULT1B1 Silent rs10428410 4 70601290 [T/C] NM_014465 SULT1B1 Silent rs1847364 4 70601326 [T/C] NM_014465 SULT1B1 Silent rs11731028 4 70602840 [T/C] NM_014465 SULT1B1 Silent rs2089075 4 70604618 [A/G] NM_014465 SULT1B1 Silent rs1847361 4 70609040 [T/C] NM_014465 SULT1B1 Silent rs13115291 4 70609968 [T/C] NM_014465 SULT1B1 Silent rs11727948 4 70612712 [A/G] NM_014465 SULT1B1 Silent rs1604747 4 70614259 [A/G] NM_014465 SULT1B1 Silent rs1354360 4 70616322 [A/G] NM_014465 SULT1B1 Silent rs7659955 4 70616955 [T/C] NM_014465 SULT1B1 Silent rs11569731 4 70621074 [A/G] NM_014465 SULT1B1 Silent rs1847359 4 70629413 [T/C] rs17147627 4 70630803 [C/G] rs13101500 4 70631294 [A/C] rs6835699 4 70634942 [A/G] rs12499134 4 70667521 [A/G] rs1813685 4 70667744 [T/C] rs2014777 4 70671743 [A/G] rs2015538 4 70674638 [A/G] rs7662705 4 70676336 [A/G] rs1220709 4 70677967 [T/C] rs1503721 4 70679571 [T/C] rs1581680 4 70684350 [T/C] rs1220718 4 70694646 [A/G] rs17147766 4 70701146 [T/G] rs1529039 4 70702006 [T/C] rs1503726 4 70702069 [A/G] rs6845469 4 70702196 [T/G] rs10213454 4 70702279 [A/G] rs17147770 4 70702834 [A/G] rs11249464 4 70703299 [T/C] rs1220726 4 70704206 [T/C] rs1910465 4 70704542 [A/G] rs13102618 4 70704877 [A/G] rs1220725 4 70706366 [A/C] rs11573801 4 70706991 [A/G] NM_005420 SULT1E1 EXON Silent rs1220724 4 70707945 [A/G] NM_005420 SULT1E1 Silent rs11573799 4 70708094 [T/C] NM_005420 SULT1E1 Silent rs2331821 4 70708461 [T/C] NM_005420 SULT1E1 Silent rs1238574 4 70709023 [T/C] NM_005420 SULT1E1 Silent rs3775779 4 70709207 [T/A] NM_005420 SULT1E1 Silent rs11573793 4 70709367 [T/A] NM_005420 SULT1E1 Silent rs3775778 4 70709432 [T/G] NM_005420 SULT1E1 Silent rs3775777 4 70709510 [A/G] NM_005420 SULT1E1 Silent rs11573792 4 70709603 [A/G] NM_005420 SULT1E1 Silent rs11573791 4 70709794 [A/G] NM_005420 SULT1E1 Silent rs11573789 4 70710656 [T/C] NM_005420 SULT1E1 Silent rs11573788 4 70710775 [T/C] NM_005420 SULT1E1 Silent rs2055533 4 70713066 [T/C] NM_005420 SULT1E1 Silent rs11573781 4 70713748 [A/G] NM_005420 SULT1E1 Silent rs11573780 4 70713767 [T/C] NM_005420 SULT1E1 Silent rs11573779 4 70714063 [T/G] NM_005420 SULT1E1 Silent rs4149535 4 70714171 [T/G] NM_005420 SULT1E1 Silent rs11573778 4 70714414 [T/C] NM_005420 SULT1E1 Silent rs3775776 4 70714488 [A/G] NM_005420 SULT1E1 Silent rs11573777 4 70714631 [A/C] NM_005420 SULT1E1 Silent rs11573775 4 70714820 [A/G] NM_005420 SULT1E1 Silent rs11573771 4 70715954 [T/C] NM_005420 SULT1E1 Silent rs11573770 4 70716022 [A/G] NM_005420 SULT1E1 Silent rs11573769 4 70716148 [T/G] NM_005420 SULT1E1 Silent rs1220715 4 70716627 [T/G] NM_005420 SULT1E1 Silent rs4149534 4 70718005 [T/C] NM_005420 SULT1E1 Silent rs4149533 4 70718036 [T/C] NM_005420 SULT1E1 Silent rs11573768 4 70718083 [T/G] NM_005420 SULT1E1 Silent rs3775775 4 70718282 [A/G] NM_005420 SULT1E1 Silent rs13113889 4 70718303 [T/C] NM_005420 SULT1E1 Silent rs11573765 4 70718732 [A/G] NM_005420 SULT1E1 Silent rs1220716 4 70718977 [T/C] NM_005420 SULT1E1 Silent rs11573762 4 70719113 [A/T] NM_005420 SULT1E1 Silent rs3775774 4 70719238 [T/C] NM_005420 SULT1E1 Silent rs10019305 4 70719533 [A/G] NM_005420 SULT1E1 Silent rs4235086 4 70720800 [T/C] NM_005420 SULT1E1 Silent rs4149531 4 70721509 [T/C] NM_005420 SULT1E1 Silent rs11573758 4 70721582 [A/G] NM_005420 SULT1E1 Silent rs11573756 4 70721974 [A/G] NM_005420 SULT1E1 Silent rs11573755 4 70722283 [T/C] NM_005420 SULT1E1 Silent rs4694036 4 70722297 [A/T] NM_005420 SULT1E1 Silent rs11249470 4 70723196 [A/G] NM_005420 SULT1E1 Silent rs11569705 4 70723299 [A/C] NM_005420 SULT1E1 EXON Missense_D22Y rs11573748 4 70723750 [T/G] NM_005420 SULT1E1 Silent rs3822173 4 70723815 [A/G] NM_005420 SULT1E1 Silent rs11573747 4 70723858 [T/C] NM_005420 SULT1E1 Silent rs3775770 4 70724270 [T/C] NM_005420 SULT1E1 Silent rs11573744 4 70724707 [T/G] NM_005420 SULT1E1 Silent rs11573743 4 70724835 [T/C] NM_005420 SULT1E1 Silent rs11573742 4 70724949 [A/G] NM_005420 SULT1E1 Silent rs4149527 4 70724996 [T/G] NM_005420 SULT1E1 Silent rs11573741 4 70725101 [T/C] NM_005420 SULT1E1 Silent rs3775768 4 70725112 [T/C] NM_005420 SULT1E1 Silent rs3775767 4 70725421 [T/C] NM_005420 SULT1E1 Silent rs1534672 4 70725698 [T/C] NM_005420 SULT1E1 Silent rs11573740 4 70726012 [A/C] rs4149526 4 70726094 [A/G] rs4149525 4 70726399 [T/C] rs4149524 4 70726468 [A/G] rs11573738 4 70726592 [A/G] rs11573737 4 70726644 [T/C] rs11573735 4 70726805 [A/G] rs11573734 4 70726814 [T/C] rs11573733 4 70727355 [T/C] rs7655478 4 70729022 [T/C] rs6600803 4 70729266 [T/G] rs2178320 4 70731197 [T/C] rs1590128 4 70734059 [A/G] rs1220831 4 70741799 [T/C] rs13122069 4 70753524 [A/G] rs12507764 4 70756086 [A/G] rs17147830 4 70759142 [T/C] rs17628741 4 70760559 [T/C] rs2172159 4 70765416 [A/G] rs10518069 4 70768646 [T/G] rs7437229 4 70774400 [T/C] rs17147844 4 70778543 [T/C] rs12650947 4 70783348 [T/C] rs17629282 4 70783811 [T/C] rs1220823 4 70784305 [T/C] rs4694257 4 70789170 [T/C] rs1220841 4 70795699 [A/G] rs17696835 4 70796390 [A/G] rs10030475 4 70807771 [T/C] NM_001890,NM_001025104 CSN1S1,CSN1S1 EXON Missense_A117V,Missense_A108V rs1237375 4 70811806 [T/C] NM_001890,NM_001025104 CSN1S1,CSN1S1 Silent,Silent rs1002082 4 70813971 [A/G] rs1388354 4 70818296 [A/G] rs1491429 4 70820800 [A/G] rs9994584 4 70833723 [T/G] rs776840 4 70836155 [T/G] rs1356118 4 70846936 [A/G] rs6845245 4 70854941 [T/C] rs776821 4 70860858 [T/C] rs17641990 4 70863901 [T/C] NM_003154,NM_001009181 STATH,STATH Silent,Silent rs10031583 4 70868585 [T/G] rs12648068 4 70871257 [A/G] rs776847 4 70892669 [T/C] rs17699715 4 70893749 [T/C] rs7667935 4 70899111 [A/G] NM_000200 HTN3 Silent rs2331856 4 70910928 [A/G] rs2138269 4 70911720 [A/C] rs6853611 4 70917031 [A/G] NM_002159 HTN1 Silent rs6854359 4 70917429 [A/G] NM_002159 HTN1 Silent rs10008606 4 70920208 [A/C] NM_002159 HTN1 Silent rs2009025 4 70920812 [A/C] NM_002159 HTN1 Silent rs17644018 4 70932305 [T/C] rs11249476 4 70934328 [T/G] NR_003720 CSN1S2AP Silent rs11249478 4 70934473 [T/G] NR_003720 CSN1S2AP Silent rs2063818 4 70935067 [A/G] NR_003720 CSN1S2AP Silent rs9998140 4 70957090 [A/C] rs1040281 4 70968924 [A/G] rs777408 4 70972959 [T/C] rs1717600 4 70974315 [A/G] rs17148162 4 70974741 [A/C] rs6855744 4 70979385 [A/G] rs13107309 4 70980547 [T/C] rs17148188 4 70982011 [A/G] rs7685261 4 70985025 [T/C] rs1607989 4 70990224 [A/G] rs1399252 4 70999619 [A/C] NR_033311 CSN1S2BP Silent rs3775759 4 71008940 [T/C] NR_033311 CSN1S2BP Silent rs1709287 4 71013720 [T/C] rs708235 4 71018758 [T/C] rs708234 4 71019255 [A/G] rs17148265 4 71021940 [T/C] NM_214711 PRR27 Silent rs1613461 4 71024240 [T/C] NM_214711 PRR27 EXON Missense_R91C rs11735430 4 71025548 [T/G] NM_214711 PRR27 Silent rs11942432 4 71026763 [A/G] NM_214711 PRR27 Silent rs6600807 4 71032811 [A/G] rs17647132 4 71041750 [T/C] rs777406 4 71042967 [A/C] rs13105632 4 71043494 [T/C] rs13151337 4 71045118 [T/C] rs17148322 4 71045677 [A/G] rs1709276 4 71046529 [T/C] rs777390 4 71048803 [T/C] rs17652789 4 71051031 [T/C] rs869894 4 71052152 [A/C] rs17148330 4 71058996 [A/G] rs1383436 4 71061842 [T/C] rs17704351 4 71062426 [T/C] NM_017855 ODAM EXON Synonymous_L23L rs1514393 4 71063359 [T/C] NM_017855 ODAM Silent rs1514394 4 71063374 [A/G] NM_017855 ODAM Silent rs4694273 4 71067317 [A/C] NM_017855 ODAM Silent rs3196714 4 71068489 [T/C] NM_017855 ODAM EXON Missense_I222T rs12507621 4 71068966 [T/C] NM_017855 ODAM Silent rs3775757 4 71069004 [T/G] NM_017855 ODAM Silent rs3775756 4 71069113 [T/C] NM_017855 ODAM Silent rs12504890 4 71079192 [A/G] rs1828826 4 71081038 [T/C] rs17148368 4 71083238 [A/C] rs28563113 4 71088563 [T/C] rs10518072 4 71090658 [T/C] rs1514399 4 71091123 [T/C] rs2249813 4 71106017 [T/C] rs3775753 4 71109108 [A/G] NM_005212 CSN3 Silent rs13122200 4 71110852 [A/G] NM_005212 CSN3 Silent rs17654723 4 71113124 [T/C] NM_005212 CSN3 Silent rs3775739 4 71115060 [A/G] NM_005212 CSN3 EXON Missense_A145T rs1399253 4 71117202 [T/C] rs2046106 4 71121681 [A/C] rs970681 4 71126287 [T/C] rs17148451 4 71127403 [T/C] rs17656090 4 71132205 [A/C] rs17148491 4 71137121 [T/C] rs17148501 4 71141300 [T/C] rs13127641 4 71142199 [T/C] rs12510290 4 71147013 [T/C] rs1842469 4 71150652 [T/C] rs17148526 4 71151940 [A/G] rs1812922 4 71154114 [T/C] rs1976001 4 71156301 [A/G] rs17148540 4 71165491 [A/G] rs729314 4 71165706 [A/C] rs17146493 4 71166102 [T/G] rs10007509 4 71171720 [A/C] rs10024824 4 71181917 [T/C] rs4421051 4 71184850 [T/C] rs9329032 4 71185226 [A/G] rs1904851 4 71185783 [A/G] rs11940998 4 71187657 [A/G] rs2013685 4 71190111 [A/G] rs717360 4 71190301 [T/C] rs1480744 4 71191032 [A/G] rs1351419 4 71201388 [T/C] NM_033122 CABS1 EXON Missense_T211I rs2291182 4 71201648 [T/G] NM_033122 CABS1 EXON Missense_W298G rs13039 4 71201943 [A/G] NM_033122 CABS1 EXON Synonymous_X396X rs9992346 4 71206687 [T/C] rs4694051 4 71207398 [T/C] rs17148650 4 71214585 [A/G] rs1480757 4 71217628 [A/G] rs6600813 4 71218054 [T/C] rs12647928 4 71218510 [A/G] rs17660273 4 71219358 [T/C] rs17148759 4 71221837 [A/G] rs17148794 4 71226962 [A/C] NM_012390 SMR3A Silent rs1842472 4 71230068 [T/G] NM_012390 SMR3A Silent rs13137718 4 71231202 [A/G] NM_012390 SMR3A Silent rs13435339 4 71231241 [A/G] NM_012390 SMR3A Silent rs10024123 4 71232430 [T/C] NM_012390 SMR3A EXON Missense_C42R rs1813261 4 71233986 [A/C] rs17661300 4 71236847 [A/G] rs11249497 4 71237421 [T/C] rs1480750 4 71248055 [T/C] rs6600824 4 71252241 [A/G] NM_006685 SMR3B Silent rs1490482 4 71260539 [T/C] rs1387964 4 71261913 [T/C] rs4426856 4 71263790 [T/G] NR_126503,NM_021225,NM_001302807 OPRPN,OPRPN,OPRPN Silent,Silent,Silent rs11938536 4 71264191 [A/C] NR_126503,NM_021225,NM_001302807 OPRPN,OPRPN,OPRPN Silent,Silent,Silent rs1844635 4 71265172 [A/C] NR_126503,NM_021225,NM_001302807 OPRPN,OPRPN,OPRPN Silent,Silent,Silent rs7682761 4 71265840 [T/C] NR_126503,NM_021225,NM_001302807 OPRPN,OPRPN,OPRPN Silent,Silent,Silent rs6827846 4 71272547 [A/G] NR_126503,NM_021225,NM_001302807 OPRPN,OPRPN,OPRPN Silent,Silent,Silent rs17662455 4 71290636 [A/G] rs10018283 4 71296033 [A/G] rs17148915 4 71296050 [T/C] rs962922 4 71309233 [T/C] NM_001145006 MUC7 Silent rs12645253 4 71310245 [A/G] NM_001145006 MUC7 Silent rs2172006 4 71311646 [A/C] NM_001145006 MUC7 Silent rs1109501 4 71329490 [A/G] NM_001145006 MUC7 Silent rs7684907 4 71337964 [A/C] NM_001145006,NM_001145007,NM_152291 MUC7,MUC7,MUC7 EXON Silent,Silent,Silent rs6826961 4 71346701 [C/G] NM_001145006,NM_001145007,NM_152291 MUC7,MUC7,MUC7 EXON Missense_N80K,Missense_N80K,Missense_N80K rs3733491 4 71347854 [A/G] NM_001145006,NM_001145007,NM_152291 MUC7,MUC7,MUC7 EXON Silent,Silent,Silent rs4694317 4 71351436 [A/C] rs6837080 4 71353586 [A/G] rs6852383 4 71355575 [T/C] rs17838972 4 71357077 [A/G] rs17148999 4 71362025 [A/G] rs17732035 4 71362151 [T/C] rs17675439 4 71363289 [A/G] rs3864157 4 71368508 [T/G] rs3852091 4 71372099 [A/G] rs17149002 4 71372596 [A/G] rs17732605 4 71376022 [T/C] rs3852093 4 71376829 [A/G] rs28414132 4 71384287 [T/C] rs28420645 4 71385167 [T/C] NM_212557,NM_001286731 AMTN,AMTN Silent,Silent rs7660807 4 71388551 [A/G] NM_212557,NM_001286731 AMTN,AMTN EXON Missense_N45S,Missense_N44S rs4024031 4 71403159 [T/C] rs28408923 4 71407154 [T/C] rs28770195 4 71408454 [T/C] rs28719939 4 71419827 [T/C] rs3852105 4 71422796 [T/C] rs1490470 4 71439354 [A/G] rs17149024 4 71440317 [A/G] rs28661403 4 71453028 [A/G] rs28660083 4 71455685 [A/G] rs28432331 4 71455961 [T/C] rs3924573 4 71459248 [A/G] NM_016519 AMBN Silent rs28509200 4 71466451 [T/C] NM_016519 AMBN Silent rs4694075 4 71466914 [T/C] NM_016519 AMBN Silent rs7439186 4 71469604 [T/C] NM_016519 AMBN EXON Missense_A255V rs7680880 4 71472426 [A/G] NM_016519 AMBN EXON Synonymous_A441A rs28498138 4 71480923 [T/C] rs28690964 4 71481109 [A/C] rs12640848 4 71506412 [A/G] NM_031889 ENAM Silent rs7671281 4 71509086 [T/C] NM_031889 ENAM EXON Missense_I648T rs3796703 4 71509314 [T/C] NM_031889 ENAM EXON Missense_P724L rs3796704 4 71509431 [A/G] NM_031889 ENAM EXON Missense_R763Q rs7679569 4 71510914 [T/C] NM_031889 ENAM EXON Silent rs1055660 4 71512371 [T/C] NM_031889 ENAM EXON Silent rs16845288 4 71514505 [T/C] rs13146209 4 71520178 [T/C] rs16845299 4 71520630 [T/C] rs12331718 4 71521971 [T/C] NM_144646 JCHAIN EXON Silent rs16845329 4 71523724 [A/C] NM_144646 JCHAIN Silent rs16845340 4 71525908 [T/C] NM_144646 JCHAIN Silent rs16845359 4 71540886 [A/C] rs16845365 4 71542095 [T/C] rs16845371 4 71547009 [A/G] rs16845375 4 71548846 [A/G] rs10030711 4 71550980 [A/G] rs16845380 4 71552305 [T/C] rs16845383 4 71552398 [A/G] rs3733488 4 71554275 [T/C] NM_020368 UTP3 EXON Silent rs7697206 4 71564925 [A/G] rs7678779 4 71583087 [A/C] NM_001130709 RUFY3 Silent rs28475626 4 71587040 [T/C] NM_001130709 RUFY3 Silent rs10009233 4 71597069 [T/G] NM_001130709,NM_001037442,NM_001291994,NM_014961 RUFY3,RUFY3,RUFY3,RUFY3 Silent,Silent,Silent,Silent rs16845433 4 71625511 [T/C] NM_001130709,NM_001037442,NM_001291994,NM_014961,NM_001345840,NM_001291993 RUFY3,RUFY3,RUFY3,RUFY3,RUFY3,RUFY3 Silent,Silent,Silent,Silent,Silent,Silent rs3775730 4 71626572 [A/G] NM_001130709,NM_001037442,NM_001291994,NM_014961,NM_001345840,NM_001291993 RUFY3,RUFY3,RUFY3,RUFY3,RUFY3,RUFY3 Silent,Silent,Silent,Silent,Silent,Silent rs10015958 4 71629537 [T/C] NM_001130709,NM_001037442,NM_001291994,NM_014961,NM_001345840,NM_001291993 RUFY3,RUFY3,RUFY3,RUFY3,RUFY3,RUFY3 Silent,Silent,Silent,Silent,Silent,Silent rs2278134 4 71630161 [T/C] NM_001130709,NM_001037442,NM_001291994,NM_014961,NM_001345840,NM_001291993 RUFY3,RUFY3,RUFY3,RUFY3,RUFY3,RUFY3 Silent,Silent,Silent,Silent,Silent,Silent rs4367145 4 71641769 [A/G] NM_001130709,NM_001037442,NM_001291994,NM_014961,NM_001345840,NM_001291993 RUFY3,RUFY3,RUFY3,RUFY3,RUFY3,RUFY3 Silent,Silent,Silent,Silent,Silent,Silent rs10012829 4 71658684 [T/C] NM_001037442,NM_001291994,NM_014961,NM_001345840,NM_001291993 RUFY3,RUFY3,RUFY3,RUFY3,RUFY3 EXON Silent,Silent,Silent,Silent,Silent rs1043903 4 71672653 [A/G] NM_001037442,NM_001291993 RUFY3,RUFY3 EXON Silent,Silent rs1043906 4 71672811 [T/C] NM_001037442,NM_001291993 RUFY3,RUFY3 EXON Silent,Silent rs7681549 4 71673137 [T/C] NM_001037442,NM_001291993 RUFY3,RUFY3 EXON Silent,Silent rs1551892 4 71676233 [T/G] rs11737063 4 71680954 [A/G] rs10938024 4 71685092 [A/C] NM_001098477,NM_002092 GRSF1,GRSF1 EXON Silent,Silent rs7686378 4 71686450 [T/C] NM_001098477,NM_002092 GRSF1,GRSF1 EXON Silent,Silent rs13112870 4 71700247 [T/C] NM_001098477,NM_002092 GRSF1,GRSF1 Silent,Silent rs3775729 4 71702684 [T/C] NM_001098477,NM_002092 GRSF1,GRSF1 Silent,Silent rs13137120 4 71719138 [A/G] rs6446909 4 71724706 [A/G] rs12649012 4 71748245 [A/G] rs10433674 4 71761726 [T/C] rs11727576 4 71767788 [T/G] rs10026933 4 71768930 [T/C] NM_173468,NM_001244766,NM_001244767 MOB1B,MOB1B,MOB1B Silent,Silent,Silent rs12512502 4 71776935 [A/C] NM_173468,NM_001244766,NM_001244767 MOB1B,MOB1B,MOB1B Silent,Silent,Silent rs11737727 4 71781554 [A/G] NM_173468,NM_001244766,NM_001244767 MOB1B,MOB1B,MOB1B Silent,Silent,Silent rs10020830 4 71791293 [T/C] NM_173468,NM_001244766,NM_001244767 MOB1B,MOB1B,MOB1B Silent,Silent,Silent rs6446945 4 71791502 [T/C] NM_173468,NM_001244766,NM_001244767 MOB1B,MOB1B,MOB1B Silent,Silent,Silent rs6826930 4 71794649 [T/C] NM_173468,NM_001244766,NM_001244767 MOB1B,MOB1B,MOB1B Silent,Silent,Silent rs10016211 4 71802434 [T/C] NM_173468,NM_001244766,NM_001244767 MOB1B,MOB1B,MOB1B Silent,Silent,Silent rs10003046 4 71806349 [A/G] NM_173468,NM_001244766,NM_001244767 MOB1B,MOB1B,MOB1B Silent,Silent,Silent rs16845597 4 71812665 [A/G] NM_173468,NM_001244766,NM_001244767 MOB1B,MOB1B,MOB1B Silent,Silent,Silent rs28673341 4 71817710 [T/C] NM_173468,NM_001244766,NM_001244767 MOB1B,MOB1B,MOB1B Silent,Silent,Silent rs6446977 4 71849697 [T/C] NM_173468,NM_001244766 MOB1B,MOB1B EXON Silent,Silent rs6842838 4 71849888 [T/G] NM_173468,NM_001244766 MOB1B,MOB1B EXON Silent,Silent rs3733399 4 71850271 [A/G] NM_173468,NM_001244766 MOB1B,MOB1B EXON Silent,Silent rs6836323 4 71851676 [A/C] NM_173468,NM_001244766 MOB1B,MOB1B EXON Silent,Silent rs1385985 4 71852410 [A/G] NM_173468,NM_001244766 MOB1B,MOB1B EXON Silent,Silent rs7689093 4 71858122 [A/G] rs2035576 4 71860754 [T/G] NM_000788 DCK Silent rs10805074 4 71874331 [A/G] NM_000788 DCK Silent rs7684954 4 71875237 [A/G] NM_000788 DCK Silent rs4694362 4 71893864 [T/C] NM_000788 DCK Silent rs1843614 4 71913507 [T/C] rs10518081 4 71917988 [A/G] rs10805077 4 71926314 [A/C] rs16845705 4 71926713 [A/G] rs11941079 4 71937445 [A/G] rs10518083 4 71948304 [T/C] rs6816128 4 71958094 [A/G] rs4694373 4 71975779 [T/C] rs6831852 4 71978043 [A/G] rs12330929 4 71979558 [T/C] rs11724714 4 71982137 [T/C] rs16845785 4 71982160 [T/C] rs7694673 4 71989808 [A/G] rs17688758 4 71997259 [T/C] rs2123430 4 71999712 [A/G] rs7694411 4 72006446 [T/C] rs6845432 4 72016176 [A/C] rs16845929 4 72017058 [T/C] rs17689531 4 72022775 [T/C] rs16845941 4 72026724 [A/G] rs1979537 4 72027476 [A/C] rs873954 4 72032466 [T/C] rs10938136 4 72040651 [A/G] rs1377285 4 72053574 [A/C] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs2198341 4 72063044 [A/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs2579302 4 72069713 [A/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs4521314 4 72084653 [A/C] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs1026272 4 72091349 [A/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs1026270 4 72091923 [T/C] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs16846059 4 72104784 [A/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs2579362 4 72105088 [T/C] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs10013437 4 72106327 [A/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs12506660 4 72108593 [T/C] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs9790757 4 72115097 [T/C] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs2060903 4 72117691 [A/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs13147721 4 72127321 [A/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs2602098 4 72135455 [T/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs1377287 4 72136575 [A/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs2363719 4 72138216 [A/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs2602049 4 72147070 [A/C] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs1031420 4 72147944 [T/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs1901709 4 72149030 [A/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs930754 4 72163134 [T/C] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs2602059 4 72169421 [A/C] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs16846254 4 72180937 [A/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs1377286 4 72183646 [A/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs11727507 4 72199788 [A/G] NM_001098484,NM_001134742 SLC4A4,SLC4A4 Silent,Silent rs16846305 4 72237431 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs16846318 4 72239375 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs6852522 4 72257715 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs4314260 4 72278430 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs6854303 4 72282753 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs13124079 4 72304002 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs4130912 4 72322773 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs6840014 4 72335972 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs4600889 4 72337490 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs4639040 4 72340242 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs6846301 4 72347491 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs4370107 4 72348514 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs16846453 4 72355616 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs4469035 4 72360478 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs10031807 4 72382471 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs6842334 4 72386350 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs1377527 4 72387348 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs2886107 4 72387926 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs1453445 4 72391695 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs7683903 4 72396727 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs3775162 4 72397710 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs16846517 4 72397788 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 EXON Synonymous_L726L,Synonymous_L726L,Synonymous_L682L rs7693843 4 72405132 [T/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs1869377 4 72406365 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs3733362 4 72412029 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs11937245 4 72415556 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs2123667 4 72415807 [T/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs16846575 4 72421709 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs1453475 4 72422691 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs1453474 4 72423624 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs1453458 4 72425863 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 EXON Synonymous_H997H,Synonymous_H997H,Synonymous_H953H rs1031453 4 72427450 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs13148532 4 72428522 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs3816468 4 72433300 [T/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 Silent,Silent,Silent rs1062677 4 72433545 [A/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 EXON Silent,Missense_I1074L,Silent rs1453453 4 72433759 [T/C] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 EXON Silent,Silent,Silent rs1043218 4 72436235 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 EXON Silent,Silent,Silent rs9997127 4 72436498 [A/G] NM_001098484,NM_001134742,NM_003759 SLC4A4,SLC4A4,SLC4A4 EXON Silent,Silent,Silent rs16846687 4 72438028 [T/C] rs1377523 4 72447421 [A/C] rs1597978 4 72469183 [A/G] rs17763915 4 72476761 [T/C] rs10212827 4 72481753 [T/C] rs1918088 4 72497189 [T/G] rs1526691 4 72513178 [T/C] rs2219070 4 72515260 [T/C] rs9654062 4 72528017 [A/G] rs2177921 4 72531761 [A/G] rs13150933 4 72531863 [T/C] rs12501894 4 72541092 [A/G] rs6446756 4 72543907 [T/C] rs4694421 4 72545947 [T/G] rs4694425 4 72554521 [T/C] rs377687 4 72569065 [A/G] rs6845026 4 72569693 [T/C] rs1526692 4 72578724 [A/G] rs842990 4 72578956 [T/G] rs4694105 4 72592214 [T/C] rs1491716 4 72595063 [A/G] rs6830700 4 72595117 [T/C] rs6837549 4 72596821 [T/G] rs12512631 4 72601331 [T/C] rs705117 4 72608115 [T/C] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs2282679 4 72608383 [T/G] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs222047 4 72610208 [A/C] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs222046 4 72610850 [T/C] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs16846912 4 72611215 [A/G] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs705119 4 72613036 [A/C] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs1491709 4 72613566 [A/G] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs705120 4 72614140 [A/C] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs4588 4 72618323 [T/G] NM_000583,NM_001204306,NM_001204307 GC,GC,GC EXON Missense_T436K,Missense_T436K,Missense_T455K rs7041 4 72618334 [A/C] NM_000583,NM_001204306,NM_001204307 GC,GC,GC EXON Missense_D432E,Missense_D432E,Missense_D451E rs4752 4 72622566 [A/G] NM_000583,NM_001204306,NM_001204307 GC,GC,GC EXON Synonymous_C299C,Synonymous_C299C,Synonymous_C318C rs4364228 4 72623347 [A/G] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs3775152 4 72630642 [A/C] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs3737549 4 72631668 [A/G] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs705124 4 72632643 [A/G] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs222016 4 72634975 [A/G] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs222020 4 72636272 [T/C] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs222023 4 72637080 [A/G] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs1491718 4 72641279 [T/C] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs1352844 4 72647749 [T/C] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs1352845 4 72647762 [A/G] NM_000583,NM_001204306,NM_001204307 GC,GC,GC Silent,Silent,Silent rs3733359 4 72649774 [A/G] NM_000583,NM_001204306,NM_001204307 GC,GC,GC EXON Silent,Silent,Silent rs11939173 4 72672158 [A/G] rs7442603 4 72673682 [A/G] rs842889 4 72686078 [T/C] rs11737702 4 72689926 [A/G] rs10518091 4 72692763 [A/G] rs842872 4 72695059 [A/G] rs16847105 4 72695479 [T/G] rs9291163 4 72699705 [T/C] rs1520498 4 72699778 [A/G] rs9992215 4 72700747 [A/G] rs11945677 4 72703606 [A/G] rs6837292 4 72704949 [T/C] rs6851050 4 72707118 [A/G] rs962226 4 72707400 [T/C] rs962227 4 72707517 [A/G] rs1851024 4 72707821 [A/G] rs7681566 4 72709580 [A/G] rs12639968 4 72712872 [T/C] rs7683624 4 72723948 [A/C] rs6845801 4 72730996 [A/G] rs6810725 4 72735132 [A/G] rs13113067 4 72739098 [T/G] rs9637552 4 72739803 [A/G] rs10033936 4 72743474 [A/G] rs10022720 4 72743549 [T/C] rs2365520 4 72744626 [A/G] rs16847200 4 72751686 [A/G] rs6814839 4 72751722 [A/G] rs4694440 4 72756782 [T/C] rs4694441 4 72757529 [A/G] rs1474198 4 72769012 [T/C] rs16847219 4 72779309 [A/G] rs16847227 4 72780146 [T/C] rs12504562 4 72784005 [T/C] rs1520499 4 72791849 [T/C] rs10035034 4 72792667 [T/C] rs1973750 4 72797923 [A/G] rs1520497 4 72800493 [T/G] rs17774208 4 72801285 [T/G] rs2139639 4 72806951 [A/G] rs10937987 4 72809000 [A/G] rs6446772 4 72811523 [T/C] rs11726886 4 72822599 [A/C] rs11733593 4 72834313 [T/C] rs4583729 4 72841348 [A/C] rs7683913 4 72845549 [A/G] rs9968268 4 72854456 [T/C] rs6827969 4 72873693 [T/G] rs28737202 4 72873814 [A/G] rs11723796 4 72875597 [T/C] rs7699080 4 72885899 [T/C] rs10028416 4 72891467 [A/G] rs12503480 4 72903792 [T/C] NM_004885 NPFFR2 Silent rs12512773 4 72905089 [A/G] NM_004885,NM_053036,NM_001144756 NPFFR2,NPFFR2,NPFFR2 EXON Silent,Silent,Silent rs7675387 4 72921718 [T/G] NM_004885,NM_053036,NM_001144756 NPFFR2,NPFFR2,NPFFR2 Silent,Silent,Silent rs7678974 4 72927226 [A/G] NM_004885,NM_053036,NM_001144756 NPFFR2,NPFFR2,NPFFR2 Silent,Silent,Silent rs4296652 4 72938462 [T/C] NM_004885,NM_053036,NM_001144756 NPFFR2,NPFFR2,NPFFR2 Silent,Silent,Silent rs7674293 4 72947764 [A/G] NM_004885,NM_053036,NM_001144756 NPFFR2,NPFFR2,NPFFR2 Silent,Silent,Silent rs11734316 4 72952141 [A/G] NM_004885,NM_053036,NM_001144756 NPFFR2,NPFFR2,NPFFR2 Silent,Silent,Silent rs12108353 4 72963615 [T/C] NM_004885,NM_053036,NM_001144756 NPFFR2,NPFFR2,NPFFR2 Silent,Silent,Silent rs10034862 4 72993872 [A/C] NM_004885,NM_053036,NM_001144756 NPFFR2,NPFFR2,NPFFR2 Silent,Silent,Silent rs10004420 4 72994296 [A/G] NM_004885,NM_053036,NM_001144756 NPFFR2,NPFFR2,NPFFR2 Silent,Silent,Silent rs9790741 4 73000885 [T/G] NM_004885,NM_053036,NM_001144756 NPFFR2,NPFFR2,NPFFR2 Silent,Silent,Silent rs16847538 4 73016170 [T/C] rs4367144 4 73023727 [T/G] rs17775363 4 73036901 [A/G] rs6851214 4 73038187 [A/G] rs7665177 4 73055314 [T/C] rs1513895 4 73061027 [T/C] rs10805048 4 73073061 [T/C] rs957045 4 73075994 [A/C] rs7662481 4 73088582 [A/G] rs10029245 4 73091934 [T/C] rs970649 4 73096168 [A/C] rs10938012 4 73096392 [A/G] rs16847697 4 73106712 [A/G] rs16847703 4 73108169 [A/G] rs1554017 4 73117353 [A/G] rs6446825 4 73139890 [T/C] rs768029 4 73140229 [T/C] rs1369095 4 73144182 [T/C] rs9994557 4 73146274 [A/G] rs16847814 4 73165274 [T/G] NM_014243 ADAMTS3 Silent rs2304362 4 73186404 [A/C] NM_014243 ADAMTS3 Silent rs1897814 4 73195704 [T/C] NM_014243 ADAMTS3 Silent rs16847840 4 73199140 [A/C] NM_014243 ADAMTS3 Silent rs1369093 4 73245191 [T/C] NM_014243 ADAMTS3 Silent rs1369088 4 73251173 [A/G] NM_014243 ADAMTS3 Silent rs17722955 4 73257944 [T/C] NM_014243 ADAMTS3 Silent rs10019624 4 73264368 [T/C] NM_014243 ADAMTS3 Silent rs10518102 4 73268874 [T/G] NM_014243 ADAMTS3 Silent rs13112404 4 73273605 [T/C] NM_014243 ADAMTS3 Silent rs922739 4 73284282 [A/G] NM_014243 ADAMTS3 Silent rs1481667 4 73293130 [T/C] NM_014243 ADAMTS3 Silent rs11727604 4 73295961 [T/C] NM_014243 ADAMTS3 Silent rs10024063 4 73328204 [A/G] NM_014243 ADAMTS3 Silent rs17725271 4 73333387 [T/C] NM_014243 ADAMTS3 Silent rs1383930 4 73334051 [T/G] NM_014243 ADAMTS3 Silent rs6823875 4 73335098 [A/C] NM_014243 ADAMTS3 Silent rs788919 4 73353894 [T/C] NM_014243 ADAMTS3 Silent rs700514 4 73361819 [A/C] NM_014243 ADAMTS3 Silent rs11730719 4 73363929 [T/C] NM_014243 ADAMTS3 Silent rs788927 4 73364994 [A/C] NM_014243 ADAMTS3 Silent rs788935 4 73379012 [T/C] NM_014243 ADAMTS3 Silent rs6446834 4 73404916 [T/C] NM_014243 ADAMTS3 Silent rs700513 4 73409668 [T/C] NM_014243 ADAMTS3 Silent rs788912 4 73412231 [A/G] NM_014243 ADAMTS3 Silent rs788911 4 73413223 [T/G] NM_014243 ADAMTS3 Silent rs788908 4 73414286 [T/C] NM_014243 ADAMTS3 EXON Missense_R138K rs12645174 4 73431464 [T/C] NM_014243 ADAMTS3 Silent rs1518492 4 73433875 [A/G] NM_014243 ADAMTS3 Silent rs7670571 4 73435404 [T/C] rs4694494 4 73445607 [A/G] rs753944 4 73449917 [T/C] rs719382 4 73454114 [T/C] rs11933831 4 73454510 [A/G] rs13104467 4 73455382 [T/C] rs6831742 4 73458049 [A/G] rs16848243 4 73458117 [T/C] rs1518485 4 73470972 [T/C] rs1401144 4 73506817 [A/G] rs11939290 4 73508425 [A/G] rs11728435 4 73509826 [T/C] rs1878758 4 73514301 [A/C] rs12644269 4 73518909 [T/C] rs16848436 4 73523909 [T/C] rs9784530 4 73527617 [T/C] rs13103561 4 73528682 [T/C] rs16848464 4 73529400 [A/G] rs16848482 4 73530700 [T/C] rs2086471 4 73543031 [A/G] rs11722134 4 73556348 [T/G] rs16848533 4 73572187 [T/C] rs10518108 4 73575548 [A/G] rs986397 4 73578725 [A/G] rs9291178 4 73586055 [T/C] rs1481108 4 73609026 [T/C] rs316431 4 73614025 [T/C] rs4694517 4 73617478 [T/C] rs4694519 4 73618256 [A/C] rs4694523 4 73618440 [T/C] rs2366447 4 73633046 [T/C] rs1006667 4 73637255 [T/G] rs1383626 4 73637861 [A/G] rs316438 4 73640679 [A/G] rs316440 4 73640771 [A/G] rs316424 4 73651309 [A/G] rs16848634 4 73656391 [A/G] rs1381252 4 73673070 [A/C] rs1842553 4 73674204 [A/G] rs1841587 4 73674780 [T/C] rs1383623 4 73676145 [T/C] rs4146484 4 73680605 [T/C] rs4694548 4 73681946 [A/G] rs4694549 4 73683824 [T/C] rs221593 4 73686750 [A/G] rs6446885 4 73689660 [T/C] rs315335 4 73693542 [A/G] rs221594 4 73694092 [A/G] rs315337 4 73694511 [T/C] rs2126207 4 73711378 [T/C] rs315359 4 73720317 [T/G] rs186403 4 73740674 [T/C] rs315383 4 73742111 [A/G] rs315390 4 73744442 [T/C] rs9291180 4 73757679 [A/G] rs7698530 4 73759117 [A/G] rs17779822 4 73761638 [A/G] rs7677865 4 73762643 [T/C] rs17779898 4 73768487 [A/C] rs11930953 4 73769708 [T/C] rs919047 4 73770378 [A/G] rs1346133 4 73774717 [A/G] rs6814202 4 73781518 [A/C] rs11941162 4 73784340 [A/G] rs6840693 4 73796573 [T/C] rs1895855 4 73799039 [A/G] rs7688718 4 73803268 [A/C] rs1381015 4 73812806 [A/C] rs6847507 4 73819690 [T/C] rs13102676 4 73821904 [T/G] rs2059569 4 73824798 [A/G] rs2366711 4 73832518 [T/G] rs6446910 4 73833081 [A/G] rs7667902 4 73837048 [A/G] rs2045680 4 73843550 [T/C] rs16849052 4 73851964 [T/C] rs2366715 4 73854103 [A/G] rs961873 4 73854191 [T/C] rs13137265 4 73854746 [A/G] rs10009409 4 73855253 [T/C] rs16849080 4 73855515 [A/G] rs1381016 4 73856466 [A/G] rs13141048 4 73857746 [T/C] rs7666763 4 73858464 [T/C] rs1381014 4 73862030 [A/C] rs7675007 4 73862194 [T/C] rs6446913 4 73891050 [A/G] rs7694505 4 73913778 [T/C] rs7438967 4 73918944 [A/G] rs1052080 4 73920622 [T/C] NM_001297732,NM_001300729,NM_001297733,NM_173827 COX18,COX18,COX18,COX18 EXON Silent,Silent,Silent,Silent rs3762883 4 73930552 [A/G] NM_001297732,NM_001300729,NM_001297733,NM_173827 COX18,COX18,COX18,COX18 EXON Synonymous_P222P,Synonymous_P224P,Synonymous_P70P,Synonymous_P221P rs2126115 4 73930893 [T/G] NM_001297732,NM_001300729,NM_001297733,NM_173827 COX18,COX18,COX18,COX18 Silent,Silent,Silent,Silent rs13109685 4 73930916 [T/C] NM_001297732,NM_001300729,NM_001297733,NM_173827 COX18,COX18,COX18,COX18 Silent,Silent,Silent,Silent rs2306057 4 73931170 [T/C] NM_001297732,NM_001300729,NM_001297733,NM_173827 COX18,COX18,COX18,COX18 Silent,Silent,Silent,Silent rs6845845 4 73937533 [A/G] rs10092 4 73940743 [A/G] NM_032217,NM_001286771,NM_015574,NM_198889 ANKRD17,ANKRD17,ANKRD17,ANKRD17 EXON Silent,Silent,Silent,Silent rs2306058 4 73942678 [T/C] NM_032217,NM_001286771,NM_015574,NM_198889 ANKRD17,ANKRD17,ANKRD17,ANKRD17 EXON Synonymous_T2577T,Synonymous_T2464T,Synonymous_T2576T,Synonymous_T2326T rs2306059 4 73942731 [A/G] NM_032217,NM_001286771,NM_015574,NM_198889 ANKRD17,ANKRD17,ANKRD17,ANKRD17 EXON Missense_H2560Y,Missense_H2447Y,Missense_H2559Y,Missense_H2309Y rs6855349 4 73956736 [A/G] NM_032217,NM_001286771,NM_015574,NM_198889 ANKRD17,ANKRD17,ANKRD17,ANKRD17 EXON Synonymous_L2203L,Synonymous_L2090L,Synonymous_L2202L,Synonymous_L1952L rs10050235 4 73988492 [A/G] NM_032217,NM_001286771,NM_015574,NM_198889 ANKRD17,ANKRD17,ANKRD17,ANKRD17 Silent,Silent,Silent,Silent rs6822576 4 73991006 [T/C] NM_032217,NM_001286771,NM_015574,NM_198889 ANKRD17,ANKRD17,ANKRD17,ANKRD17 EXON Synonymous_A1086A,Synonymous_A973A,Synonymous_A1085A,Synonymous_A835A rs13120821 4 74002341 [T/C] NM_032217,NM_001286771,NM_015574,NM_198889 ANKRD17,ANKRD17,ANKRD17,ANKRD17 Silent,Silent,Silent,Silent rs11939939 4 74010834 [A/G] NM_032217,NM_001286771,NM_015574,NM_198889 ANKRD17,ANKRD17,ANKRD17,ANKRD17 Silent,Silent,Silent,Silent rs5020219 4 74036166 [T/C] NM_032217,NM_001286771,NM_015574,NM_198889 ANKRD17,ANKRD17,ANKRD17,ANKRD17 Silent,Silent,Silent,Silent rs10035001 4 74039463 [T/C] NM_032217,NM_001286771,NM_015574,NM_198889 ANKRD17,ANKRD17,ANKRD17,ANKRD17 Silent,Silent,Silent,Silent rs16849186 4 74050725 [A/G] NM_032217,NM_001286771,NM_015574,NM_198889 ANKRD17,ANKRD17,ANKRD17,ANKRD17 Silent,Silent,Silent,Silent rs10028486 4 74058406 [A/G] NM_032217,NM_001286771,NM_015574,NM_198889 ANKRD17,ANKRD17,ANKRD17,ANKRD17 Silent,Silent,Silent,Silent rs10019296 4 74099302 [A/C] NM_032217,NM_015574,NM_198889 ANKRD17,ANKRD17,ANKRD17 Silent,Silent,Silent rs6820167 4 74141448 [T/G] rs6853164 4 74151780 [A/G] rs714825 4 74208199 [A/G] rs13125875 4 74236264 [T/C] rs4364229 4 74254678 [T/C] rs7688274 4 74268658 [A/G] rs3775486 4 74275515 [A/C] NM_000477 ALB Silent rs10022167 4 74278809 [A/G] NM_000477 ALB Silent rs2051512 4 74279549 [T/C] NM_000477 ALB Silent rs7678298 4 74284428 [T/C] NM_000477 ALB Silent rs16849364 4 74292407 [A/G] rs6829532 4 74296480 [T/C] rs12651581 4 74300880 [T/C] rs4018 4 74301313 [T/C] rs16849384 4 74302870 [T/C] NM_001354717,NM_001134 AFP,AFP Silent,Silent rs4640638 4 74303200 [A/G] NM_001354717,NM_001134 AFP,AFP Silent,Silent rs2298839 4 74310844 [A/G] NM_001354717,NM_001134 AFP,AFP Silent,Silent rs28482344 4 74313193 [T/C] NM_001354717,NM_001134 AFP,AFP EXON Missense_P149L,Synonymous_S286S rs9784480 4 74322512 [A/C] rs16849461 4 74344535 [A/G] rs7656821 4 74346234 [A/G] rs11733262 4 74357851 [A/G] NM_001133 AFM Silent rs12510870 4 74358277 [T/C] NM_001133 AFM Silent rs4694168 4 74372754 [T/C] rs4694170 4 74373060 [T/G] rs4574378 4 74402790 [T/G] rs3756073 4 74413589 [T/C] rs9996759 4 74413975 [T/C] rs10000698 4 74415939 [A/C] rs10018058 4 74426173 [A/G] rs2367154 4 74428908 [T/G] rs17191192 4 74440419 [T/C] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 EXON Silent,Silent,Silent,Silent rs17838981 4 74440552 [A/G] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 EXON Silent,Silent,Silent,Silent rs10003721 4 74440784 [T/C] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 EXON Silent,Silent,Silent,Silent rs3756068 4 74441786 [A/G] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 EXON Silent,Silent,Silent,Silent rs1745300 4 74447104 [A/C] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 Silent,Silent,Silent,Silent rs1247670 4 74447452 [T/C] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 Silent,Silent,Silent,Silent rs12507775 4 74451073 [A/G] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 EXON Missense_S131P,Missense_S163P,Missense_S119P,Missense_S131P rs1528916 4 74452469 [A/C] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 Silent,Silent,Silent,Silent rs10009048 4 74453782 [A/G] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 Silent,Silent,Silent,Silent rs10011536 4 74453857 [T/C] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 Silent,Silent,Silent,Silent rs7658159 4 74455381 [A/G] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 Silent,Silent,Silent,Silent rs6446943 4 74458223 [T/G] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 Silent,Silent,Silent,Silent rs1247655 4 74465877 [A/C] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 Silent,Silent,Silent,Silent rs6827519 4 74466409 [A/G] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 Silent,Silent,Silent,Silent rs1745288 4 74476703 [A/C] NM_177532,NM_201431,NM_001270392,NM_001270391 RASSF6,RASSF6,RASSF6,RASSF6 Silent,Silent,Silent,Silent rs1247583 4 74489271 [T/C] rs4694626 4 74494008 [T/C] rs7655717 4 74504614 [A/C] rs1247574 4 74521045 [T/C] rs4694627 4 74525356 [T/C] rs1247683 4 74527971 [T/C] rs6855668 4 74528627 [T/C] rs34945352 4 74528690 [T/G] rs2091588 4 74534437 [T/C] rs1745249 4 74540589 [A/G] rs1358594 4 74555477 [T/G] rs1247613 4 74556038 [A/G] rs1247620 4 74561560 [A/G] rs1951703 4 74572039 [T/C] rs12108656 4 74588938 [T/C] rs7654490 4 74588998 [T/G] rs7657356 4 74589784 [T/C] rs12506479 4 74592161 [T/C] rs10031141 4 74594043 [A/G] rs16849934 4 74600673 [T/G] rs2227532 4 74605532 [T/C] rs2227538 4 74606375 [T/C] NM_000584,NM_001354840 CXCL8,CXCL8 EXON Silent,Silent rs2227543 4 74607910 [T/C] NM_000584,NM_001354840 CXCL8,CXCL8 EXON Silent,Silent rs1126647 4 74609045 [A/T] NM_000584 CXCL8 EXON Silent rs1951239 4 74615746 [A/G] rs1951242 4 74617282 [T/C] rs1951699 4 74618909 [T/C] rs10938095 4 74626161 [T/C] rs2886920 4 74626945 [T/C] rs9999446 4 74628455 [A/G] rs9998340 4 74657255 [T/C] rs1951235 4 74667727 [T/C] rs6446964 4 74678093 [A/G] rs6851997 4 74679286 [A/G] rs6834586 4 74688555 [T/G] rs10805069 4 74699333 [A/G] rs17838982 4 74702263 [A/C] rs16850073 4 74703999 [T/C] NM_002993 CXCL6 EXON Silent rs6815457 4 74714003 [A/G] rs16850078 4 74714084 [T/C] rs3775487 4 74717585 [T/C] rs872914 4 74718101 [A/G] rs941758 4 74718941 [A/C] rs11723868 4 74719925 [A/G] NM_002620 PF4V1 EXON Silent rs7695276 4 74724385 [T/C] rs960821 4 74727832 [A/G] rs7438101 4 74728327 [T/C] rs2145614 4 74728508 [A/G] rs3111693 4 74730921 [A/G] rs3117598 4 74731278 [T/G] rs3117604 4 74734668 [T/C] rs1429638 4 74737930 [A/C] rs3097412 4 74748288 [T/G] rs6816849 4 74748325 [A/G] rs10518117 4 74750051 [A/G] rs516224 4 74750147 [A/G] rs4694649 4 74760458 [T/G] rs6446968 4 74762185 [T/C] rs509958 4 74762278 [A/G] rs629315 4 74776218 [T/C] rs13122604 4 74785503 [T/C] rs487834 4 74795131 [T/C] rs164754 4 74796191 [T/C] rs352024 4 74797139 [T/G] rs352018 4 74805322 [T/C] rs4694655 4 74806082 [T/C] rs4694656 4 74811199 [A/G] rs352011 4 74811802 [A/G] rs10938105 4 74826087 [A/C] rs9996748 4 74833787 [A/G] rs1595009 4 74834656 [T/C] rs4694180 4 74837402 [T/C] rs11574452 4 74846661 [A/C] NM_002619,NM_001363352 PF4,PF4 EXON Silent,Silent rs352006 4 74846877 [A/G] NM_002619,NM_001363352 PF4,PF4 EXON Silent,Silent rs183028 4 74851918 [A/G] rs352010 4 74855231 [A/G] rs2472649 4 74857708 [A/G] rs2437285 4 74860238 [T/C] rs16850345 4 74860924 [T/C] rs3775488 4 74862852 [T/C] NM_002994 CXCL5 EXON Silent rs425535 4 74863997 [T/C] NM_002994 CXCL5 EXON Synonymous_Q56Q rs6446974 4 74877895 [A/G] rs422140 4 74881968 [T/C] rs6840660 4 74887033 [T/C] rs2115694 4 74894373 [T/C] rs10033706 4 74895177 [T/G] rs164755 4 74898143 [A/G] rs4694662 4 74902283 [T/G] rs370655 4 74903134 [T/C] NM_002090 CXCL3 Silent rs181272 4 74903364 [T/C] NM_002090 CXCL3 Silent rs352042 4 74909180 [T/C] rs10019219 4 74915427 [T/G] rs352038 4 74918698 [A/G] rs16850403 4 74928201 [T/G] rs549967 4 74956116 [T/C] rs1837559 4 74959093 [A/G] rs9131 4 74963049 [T/C] NM_002089 CXCL2 EXON Silent rs1837558 4 74963584 [T/C] NM_002089 CXCL2 Silent rs11574448 4 74965562 [T/G] rs549280 4 74971196 [A/G] rs1893319 4 74973129 [T/C] rs480094 4 74987870 [T/G] rs1072389 4 74999784 [T/C] NM_001351310,NM_001351311 MTHFD2L,MTHFD2L Silent,Silent rs538775 4 75013441 [T/C] NM_001351310,NM_001351311 MTHFD2L,MTHFD2L Silent,Silent rs479117 4 75025369 [A/C] NM_001351310,NM_001351311,NR_147097,NM_001351314,NM_001144978,NM_001351329,NM_001351331,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs977598 4 75037867 [T/G] NM_001351310,NM_001351311,NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent,Silent,Silent rs16850531 4 75040696 [A/G] NM_001351310,NM_001351311,NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent,Silent,Silent rs11947475 4 75053005 [A/G] NM_001351310,NM_001351311,NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent,Silent,Silent rs564793 4 75054234 [T/C] NM_001351310,NM_001351311,NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent,Silent,Silent rs477975 4 75060567 [T/C] NM_001351310,NM_001351311,NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent,Silent,Silent rs16850636 4 75066974 [T/C] NM_001351310,NM_001351311,NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent,Silent,Silent rs480090 4 75067427 [A/G] NM_001351310,NM_001351311,NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent,Silent,Silent rs4694666 4 75067842 [T/C] NM_001351310,NM_001351311,NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent,Silent,Silent rs579866 4 75082112 [T/C] NM_001351310,NM_001351311,NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent,Silent,Silent rs1265327 4 75095061 [A/C] NM_001351310,NM_001351311,NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent,Silent,Silent rs1246576 4 75096401 [T/C] NM_001351310,NM_001351311,NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent,Silent,Silent rs1460016 4 75102993 [T/C] NM_001351310,NM_001351311,NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent,Silent,Silent rs10518120 4 75106485 [A/G] NM_001351310,NM_001351311,NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent,Silent,Silent rs1246591 4 75110540 [T/G] NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent rs16850798 4 75132286 [A/G] NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent rs16850800 4 75132331 [A/C] NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent rs7665105 4 75132798 [T/C] NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent rs10518121 4 75144008 [A/G] NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent rs10014791 4 75145466 [A/G] NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent rs9884653 4 75146143 [A/G] NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent rs9684145 4 75152436 [A/G] NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent rs10023519 4 75153710 [A/G] NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L Silent,Silent,Silent,Silent rs10011730 4 75168571 [T/C] NR_147097,NM_001351314,NM_001144978,NM_001004346 MTHFD2L,MTHFD2L,MTHFD2L,MTHFD2L EXON Silent,Silent,Silent,Silent rs16850885 4 75170140 [A/G] rs16850892 4 75172809 [T/G] rs715844 4 75186254 [T/C] rs1460001 4 75193879 [T/C] rs16850959 4 75199609 [A/G] rs17282228 4 75202277 [T/G] rs12512256 4 75205133 [T/C] rs10938119 4 75206039 [A/G] rs2125398 4 75208519 [T/G] rs7679352 4 75210003 [T/C] rs7656052 4 75215661 [A/G] rs16851013 4 75216238 [A/G] rs16851014 4 75216365 [A/G] rs16851016 4 75216675 [A/G] rs7674887 4 75217978 [T/G] rs1350666 4 75224590 [T/C] rs968061 4 75227649 [T/C] rs3806794 4 75230302 [A/C] rs10518126 4 75243119 [T/C] NM_001432 EREG Silent rs4694683 4 75243702 [A/G] NM_001432 EREG Silent rs2367707 4 75248434 [A/G] NM_001432 EREG EXON Synonymous_E117E rs2367708 4 75248544 [T/C] NM_001432 EREG Silent rs1460007 4 75254258 [A/G] NM_001432 EREG EXON Silent rs1460008 4 75254282 [A/G] NM_001432 EREG EXON Silent rs1460013 4 75258429 [A/G] rs6816797 4 75258678 [A/G] rs6845297 4 75259405 [A/G] rs10002688 4 75261407 [A/G] rs16851150 4 75266446 [T/C] rs2047193 4 75268730 [T/C] rs7693713 4 75272863 [T/C] rs13139174 4 75273080 [A/G] rs718607 4 75276524 [A/G] rs1494878 4 75282847 [A/G] rs1797605 4 75309469 [T/C] rs1691274 4 75324290 [T/C] rs11725706 4 75328108 [A/G] rs1353295 4 75329122 [A/G] rs1246415 4 75336464 [T/C] rs2609204 4 75341240 [T/C] rs7668817 4 75344134 [T/C] rs1494893 4 75356565 [T/C] rs1603131 4 75362636 [A/G] rs6447000 4 75377358 [T/C] rs6828372 4 75377395 [T/C] rs7656798 4 75387973 [T/C] rs12645461 4 75394574 [T/C] rs13104811 4 75395312 [A/G] rs1994941 4 75400315 [T/C] rs4694196 4 75404702 [T/C] rs10001945 4 75406050 [T/G] rs6447006 4 75409327 [A/G] rs7435073 4 75416565 [A/G] rs28364973 4 75478989 [T/C] rs2291714 4 75485813 [T/C] NM_001657 AREG Silent rs2291715 4 75485872 [T/C] NM_001657 AREG EXON Synonymous_F177F rs9307637 4 75510963 [T/C] rs10029098 4 75515889 [A/C] rs10050072 4 75525096 [A/G] rs7435213 4 75526108 [T/C] rs11097585 4 75528603 [A/G] rs7437891 4 75529098 [A/G] rs13435049 4 75533246 [T/C] rs11097821 4 75534357 [A/C] rs4596322 4 75546594 [T/C] rs7659874 4 75547013 [A/G] rs6534012 4 75547732 [A/C] rs13124944 4 75547845 [A/C] rs4333264 4 75555721 [T/C] rs7664990 4 75564110 [T/C] rs11099492 4 75575898 [A/G] rs3923243 4 75579453 [T/C] rs6836453 4 75589514 [A/G] rs7663639 4 75599687 [A/G] rs11930214 4 75605512 [T/C] rs11097027 4 75608390 [A/C] rs6848228 4 75619533 [T/C] rs6849245 4 75622361 [A/G] rs7691380 4 75624475 [T/C] rs10025144 4 75629315 [A/G] rs4412061 4 75632076 [T/C] rs4859540 4 75639740 [T/G] rs7686112 4 75654169 [T/C] rs7676863 4 75654722 [T/C] rs10022199 4 75658650 [T/G] rs11736577 4 75661832 [A/G] rs12503079 4 75664504 [T/C] rs4302527 4 75667398 [A/C] rs7667014 4 75668334 [T/C] rs11727548 4 75670619 [T/C] NM_001316963,NM_001729 BTC,BTC EXON Silent,Silent rs4585380 4 75673363 [A/G] NM_001316963,NM_001729 BTC,BTC Silent,Silent rs11734944 4 75681217 [A/G] NM_001316963,NM_001729 BTC,BTC Silent,Silent rs9307118 4 75682484 [A/G] NM_001316963,NM_001729 BTC,BTC Silent,Silent rs4352548 4 75683594 [T/C] NM_001316963,NM_001729 BTC,BTC Silent,Silent rs6843005 4 75684474 [A/G] NM_001316963,NM_001729 BTC,BTC Silent,Silent rs10009801 4 75694208 [T/C] NM_001316963,NM_001729 BTC,BTC Silent,Silent rs1377032 4 75712104 [T/C] NM_001316963,NM_001729 BTC,BTC Silent,Silent rs977266 4 75717601 [T/C] NM_001316963,NM_001729 BTC,BTC Silent,Silent rs1869172 4 75718366 [T/G] NM_001316963,NM_001729 BTC,BTC Silent,Silent rs1349634 4 75718547 [T/C] NM_001316963,NM_001729 BTC,BTC Silent,Silent rs1452308 4 75720151 [T/C] rs16999870 4 75729975 [A/C] rs16999874 4 75730241 [A/G] rs7667066 4 75731348 [T/G] rs984991 4 75736541 [A/G] rs1377028 4 75738792 [A/G] rs6827871 4 75745515 [A/C] rs6854845 4 75746665 [T/G] rs896577 4 75748121 [A/C] rs4859467 4 75761496 [A/C] rs6837250 4 75771799 [A/G] rs2167636 4 75777710 [A/G] rs16999967 4 75797003 [A/C] rs10017356 4 75802826 [A/C] rs1452296 4 75802937 [T/C] rs17248137 4 75808541 [A/G] rs2902802 4 75809063 [T/C] rs4859853 4 75826870 [A/C] rs16999999 4 75844039 [T/C] rs3886161 4 75845127 [A/G] rs1452303 4 75845559 [T/G] rs1377027 4 75847533 [T/C] rs17248704 4 75847586 [A/C] rs2060849 4 75851372 [A/C] rs4859880 4 75857836 [A/G] rs17248859 4 75860438 [T/C] NM_015393 PARM1 Silent rs17000026 4 75883784 [T/C] NM_015393,NR_121617 PARM1,LOC100507388 Silent,Silent rs7656977 4 75898443 [A/G] NM_015393 PARM1 Silent rs1007044 4 75899133 [A/G] NM_015393 PARM1 Silent rs6838268 4 75911362 [T/C] NM_015393 PARM1 Silent rs1816181 4 75911758 [T/C] NM_015393 PARM1 Silent rs11098369 4 75929358 [T/C] NM_015393 PARM1 Silent rs3822109 4 75937971 [T/C] NM_015393 PARM1 EXON Missense_S127L rs3775527 4 75938179 [A/G] NM_015393 PARM1 EXON Synonymous_P196P rs1062293 4 75938236 [A/G] NM_015393 PARM1 EXON Synonymous_V215V rs6824037 4 75942134 [T/C] NM_015393 PARM1 Silent rs17000093 4 75944130 [A/G] NM_015393 PARM1 Silent rs10049553 4 75945366 [T/G] NM_015393 PARM1 Silent rs4859933 4 75952499 [A/C] NM_015393 PARM1 Silent rs1365163 4 75954051 [A/C] NM_015393 PARM1 Silent rs10028207 4 75967200 [T/G] NM_015393 PARM1 Silent rs3796683 4 75971764 [T/C] NM_015393 PARM1 EXON Silent rs10012438 4 75971997 [A/G] NM_015393 PARM1 EXON Silent rs9090 4 75972413 [T/C] NM_015393 PARM1 EXON Silent rs10015446 4 75972812 [A/G] NM_015393 PARM1 EXON Silent rs1043633 4 75973830 [T/C] NM_015393 PARM1 EXON Silent rs1061570 4 75974353 [A/G] NM_015393 PARM1 EXON Silent rs11944489 4 75980925 [T/C] rs4859939 4 75982724 [T/C] rs17000192 4 75992533 [A/G] rs1365162 4 75993726 [A/G] rs17000203 4 75998962 [T/C] rs6534447 4 76005892 [T/G] rs6837969 4 76010215 [A/G] rs10000988 4 76010255 [T/C] rs4464630 4 76012856 [T/C] rs4859943 4 76014897 [T/C] rs17000249 4 76031157 [T/C] rs6534607 4 76031576 [A/G] rs6534608 4 76031652 [T/G] rs17000262 4 76034046 [T/C] rs11942566 4 76049479 [T/C] rs6853754 4 76051855 [T/C] rs769325 4 76072424 [T/C] rs7699626 4 76075268 [T/G] rs6534849 4 76075792 [T/C] rs7349670 4 76078680 [T/C] rs980761 4 76081120 [T/C] rs1391010 4 76081553 [T/C] rs1497209 4 76082809 [A/G] rs1391013 4 76086206 [T/C] rs17000313 4 76087174 [T/C] rs13113687 4 76088845 [T/G] rs12642121 4 76093188 [A/C] rs7685095 4 76106090 [T/C] rs4859946 4 76119783 [A/G] rs1497214 4 76130475 [A/G] rs6855222 4 76137551 [T/C] rs2055215 4 76138373 [A/G] rs7677444 4 76139891 [A/G] rs7681167 4 76161222 [A/G] rs7691721 4 76164287 [T/C] rs10000494 4 76168631 [A/G] rs10021538 4 76180442 [A/G] rs11099470 4 76181972 [A/G] rs11734596 4 76191643 [A/G] rs1826876 4 76192871 [T/G] rs13147022 4 76193549 [A/G] rs4859952 4 76207445 [T/C] rs7655689 4 76209438 [A/G] rs10518137 4 76209646 [A/G] rs1497216 4 76210182 [T/C] rs6535270 4 76212995 [A/G] rs6831067 4 76213925 [T/C] rs9993892 4 76231406 [A/G] rs13138899 4 76232965 [A/G] rs2131688 4 76235455 [T/C] rs2220799 4 76248474 [A/G] rs4859957 4 76249812 [T/C] rs1389441 4 76250849 [A/C] rs10019688 4 76251731 [A/C] rs2008051 4 76252397 [A/G] rs1810019 4 76252831 [T/C] rs6828992 4 76253367 [T/C] rs6813112 4 76263405 [T/C] rs1493716 4 76264496 [T/C] rs17000469 4 76268697 [A/G] rs2047097 4 76269561 [T/C] rs12501796 4 76270417 [A/C] rs7680886 4 76279001 [A/G] rs7667024 4 76281282 [T/G] NR_033964 LINC02483 Silent rs10026677 4 76281630 [T/G] NR_033964 LINC02483 Silent rs4269201 4 76283179 [T/G] NR_033964 LINC02483 Silent rs1493705 4 76284744 [T/G] NR_033964 LINC02483 Silent rs1857913 4 76285970 [T/C] NR_033964 LINC02483 Silent rs6825024 4 76290457 [T/C] rs3853187 4 76291076 [T/C] rs17000522 4 76295629 [A/G] rs2201331 4 76296421 [T/G] rs7674576 4 76299595 [T/G] rs6841628 4 76318507 [T/C] rs1026694 4 76321147 [A/C] rs7683530 4 76323522 [A/G] rs2903698 4 76332975 [A/G] rs6535429 4 76350536 [T/C] rs7677609 4 76352987 [A/G] rs11099595 4 76379793 [A/G] rs6814729 4 76382176 [T/C] rs1478174 4 76393189 [A/G] rs2126852 4 76406846 [T/C] NM_015436,NR_037914,NR_103725,NR_103724,NM_001278538,NM_001278536,NM_001278537,NM_001278539,NR_103723,NM_001009922,NR_037913 RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6833496 4 76415985 [A/G] NM_015436,NR_037914,NR_103725,NR_103724,NM_001278538,NM_001278536,NM_001278537,NM_001278539,NR_103723,NM_001009922,NR_037913 RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10518139 4 76417401 [T/C] NM_015436,NR_037914,NR_103725,NR_103724,NM_001278538,NM_001278536,NM_001278537,NM_001278539,NR_103723,NM_001009922,NR_037913 RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17000594 4 76419565 [A/G] NM_015436,NR_037914,NR_103725,NR_103724,NM_001278538,NM_001278536,NM_001278537,NM_001278539,NR_103723,NM_001009922,NR_037913 RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11731909 4 76421029 [A/C] NM_015436,NR_037914,NR_103725,NR_103724,NM_001278538,NM_001278536,NM_001278537,NM_001278539,NR_103723,NM_001009922,NR_037913 RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10020976 4 76431119 [A/G] NM_015436,NR_037914,NR_103725,NR_103724,NM_001278538,NM_001278536,NM_001278537,NM_001278539,NR_103723,NM_001009922,NR_037913 RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2903701 4 76436884 [T/C] NM_015436,NR_037914,NR_103724,NM_001278538,NM_001278536,NM_001278537,NM_001278539,NR_103723,NM_001009922,NR_037913 RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1,RCHY1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17000603 4 76443568 [A/G] NR_133920,NM_001317791,NM_144721 THAP6,THAP6,THAP6 Silent,Silent,Silent rs2126854 4 76453149 [T/C] NR_133920,NM_001317791,NM_144721 THAP6,THAP6,THAP6 EXON Silent,Silent,Silent rs11721925 4 76461012 [T/C] NR_133920 THAP6 Silent rs7681108 4 76462087 [A/G] NR_133920 THAP6 Silent rs6852097 4 76463289 [T/C] NR_133920 THAP6 Silent rs10857225 4 76464584 [A/C] NR_133920 THAP6 Silent rs17000620 4 76464991 [T/G] NR_133920 THAP6 Silent rs9998529 4 76475750 [A/C] rs2061742 4 76480880 [A/G] rs6811713 4 76482371 [A/C] NR_046430,NM_001206981,NR_046429,NM_178497,NM_001257072 ODAPH,ODAPH,ODAPH,ODAPH,ODAPH Silent,Silent,Silent,Silent,Silent rs12646094 4 76483340 [A/G] NR_046430,NM_001206981,NR_046429,NM_178497,NM_001257072 ODAPH,ODAPH,ODAPH,ODAPH,ODAPH Silent,Silent,Silent,Silent,Silent rs11099642 4 76483511 [T/G] NR_046430,NM_001206981,NR_046429,NM_178497,NM_001257072 ODAPH,ODAPH,ODAPH,ODAPH,ODAPH Silent,Silent,Silent,Silent,Silent rs17000658 4 76487438 [A/G] NR_046430,NM_001206981,NR_046429,NM_178497,NM_001257072 ODAPH,ODAPH,ODAPH,ODAPH,ODAPH Silent,Silent,Silent,Silent,Silent rs2306175 4 76489345 [T/C] NR_046430,NM_001206981,NR_046429,NM_178497,NM_001257072 ODAPH,ODAPH,ODAPH,ODAPH,ODAPH EXON Silent,Missense_L45F,Silent,Missense_P30L,Missense_P30L rs2306174 4 76489582 [A/G] NR_046430,NM_001206981,NR_046429,NM_178497,NM_001257072 ODAPH,ODAPH,ODAPH,ODAPH,ODAPH EXON Silent,Missense_V124I,Silent,Missense_R109H,Silent rs6857229 4 76491568 [A/G] rs6851864 4 76493256 [T/C] rs1871114 4 76502748 [T/C] NM_003948,NM_001330724 CDKL2,CDKL2 EXON Silent,Silent rs6829402 4 76503197 [A/G] NM_003948,NM_001330724 CDKL2,CDKL2 EXON Silent,Silent rs7668530 4 76503687 [A/C] NM_003948,NM_001330724 CDKL2,CDKL2 EXON Silent,Silent rs2867918 4 76509634 [A/G] NM_003948,NM_001330724 CDKL2,CDKL2 Silent,Silent rs4610362 4 76514964 [A/C] NM_003948,NM_001330724 CDKL2,CDKL2 Silent,Silent rs4859966 4 76519096 [A/C] NM_003948,NM_001330724 CDKL2,CDKL2 Silent,Silent rs2055997 4 76535086 [A/G] NM_003948,NM_001330724 CDKL2,CDKL2 Silent,Silent rs13123545 4 76535466 [T/C] NM_003948,NM_001330724 CDKL2,CDKL2 Silent,Silent rs1553985 4 76554604 [A/G] NM_003948,NM_001330724 CDKL2,CDKL2 Silent,Silent rs12498415 4 76558024 [T/G] rs10856853 4 76563470 [T/C] rs10002528 4 76564301 [A/T] rs11097041 4 76565970 [T/C] rs2037012 4 76566975 [A/G] rs11556146 4 76569553 [A/G] NM_012297,NM_203504,NM_203505 G3BP2,G3BP2,G3BP2 EXON Silent,Silent,Silent rs2175766 4 76572191 [A/C] NM_012297,NM_203504,NM_203505 G3BP2,G3BP2,G3BP2 Silent,Silent,Silent rs9306994 4 76576116 [A/G] NM_012297,NM_203504,NM_203505 G3BP2,G3BP2,G3BP2 Silent,Silent,Silent rs13141160 4 76585823 [T/C] NM_012297,NM_203504,NM_203505 G3BP2,G3BP2,G3BP2 Silent,Silent,Silent rs13141390 4 76585975 [T/C] NM_012297,NM_203504,NM_203505 G3BP2,G3BP2,G3BP2 Silent,Silent,Silent rs17000745 4 76596787 [T/C] NM_012297,NM_203504,NM_203505 G3BP2,G3BP2,G3BP2 Silent,Silent,Silent rs11097070 4 76622077 [T/C] rs6827809 4 76629797 [T/C] rs7665811 4 76633325 [A/G] rs7662940 4 76650443 [T/C] NM_003715,NM_001290049 USO1,USO1 Silent,Silent rs4859406 4 76660500 [A/G] NM_003715,NM_001290049 USO1,USO1 Silent,Silent rs226416 4 76692898 [T/C] NM_003715,NM_001290049 USO1,USO1 Silent,Silent rs324709 4 76695302 [T/C] NM_003715,NM_001290049 USO1,USO1 Silent,Silent rs6827302 4 76695927 [A/G] NM_003715,NM_001290049 USO1,USO1 EXON Missense_Q168R,Missense_Q172R rs2089253 4 76697211 [A/G] NM_003715,NM_001290049 USO1,USO1 Silent,Silent rs324706 4 76698424 [A/G] NM_003715,NM_001290049 USO1,USO1 Silent,Silent rs10212995 4 76712173 [A/G] NM_003715,NM_001290049 USO1,USO1 Silent,Silent rs13119659 4 76720885 [T/C] NM_003715,NM_001290049 USO1,USO1 EXON Missense_F471S,Missense_F482S rs324726 4 76722353 [A/G] NM_003715,NM_001290049 USO1,USO1 EXON Missense_R612K,Missense_R623K rs324725 4 76722579 [A/C] NM_003715,NM_001290049 USO1,USO1 Silent,Silent rs381067 4 76725245 [T/G] NM_003715,NM_001290049 USO1,USO1 Silent,Silent rs324689 4 76730195 [A/G] NM_003715,NM_001290049 USO1,USO1 EXON Missense_Q772R,Missense_Q783R rs324694 4 76730908 [T/C] NM_003715,NM_001290049 USO1,USO1 Silent,Silent rs186562 4 76738361 [A/G] rs6531940 4 76741116 [T/C] rs6847598 4 76750356 [T/C] rs10856860 4 76756059 [T/G] rs7691847 4 76761164 [A/G] rs924937 4 76769442 [A/G] rs13149236 4 76770159 [T/C] rs6811965 4 76780087 [T/C] rs1013588 4 76780943 [T/C] rs3817099 4 76788268 [A/G] NM_006239 PPEF2 Silent rs9998204 4 76790571 [A/G] NM_006239 PPEF2 Silent rs7669428 4 76800056 [A/G] NM_006239 PPEF2 Silent rs7694386 4 76803457 [A/G] NM_006239 PPEF2 Silent rs17220803 4 76805745 [A/G] NM_006239 PPEF2 Silent rs4241574 4 76808310 [T/C] NM_006239 PPEF2 Silent rs13120456 4 76809074 [T/C] NM_006239 PPEF2 Silent rs7691712 4 76809319 [A/G] NM_006239 PPEF2 Silent rs10007472 4 76817221 [T/C] NM_006239 PPEF2 Silent rs11731367 4 76817412 [A/G] NM_006239 PPEF2 Silent rs13147538 4 76818367 [A/G] NM_006239 PPEF2 Silent rs9784511 4 76824078 [T/C] rs2089252 4 76830648 [T/C] rs2135232 4 76832856 [T/C] NM_001042402 NAAA Silent rs2047985 4 76834209 [T/C] NM_001042402 NAAA Silent rs2047987 4 76834545 [A/G] NM_001042402 NAAA Silent rs6823734 4 76836137 [A/G] NM_001042402,NM_014435 NAAA,NAAA EXON Silent,Missense_F334L rs6819442 4 76839108 [T/C] NM_001042402,NM_014435,NM_001363719 NAAA,NAAA,NAAA Silent,Silent,Silent rs2869456 4 76839729 [A/C] NM_001042402,NM_014435,NM_001363719 NAAA,NAAA,NAAA Silent,Silent,Silent rs17001217 4 76842103 [T/C] NM_001042402,NM_014435,NM_001363719 NAAA,NAAA,NAAA Silent,Silent,Silent rs937788 4 76846755 [T/C] NM_001042402,NM_014435,NM_001363719 NAAA,NAAA,NAAA Silent,Silent,Silent rs7670521 4 76848886 [A/G] NM_001042402,NM_014435,NM_001363719 NAAA,NAAA,NAAA Silent,Silent,Silent rs4859571 4 76857309 [T/C] NM_001042402,NM_014435,NM_001363719 NAAA,NAAA,NAAA EXON Missense_V151I,Missense_V151I,Missense_V151I rs4859572 4 76857388 [T/C] NM_001042402,NM_014435,NM_001363719 NAAA,NAAA,NAAA EXON Synonymous_V124V,Synonymous_V124V,Synonymous_V124V rs17001248 4 76871012 [T/G] rs17001275 4 76874996 [T/C] NM_018115,NM_001288984,NM_001288983 SDAD1,SDAD1,SDAD1 Silent,Silent,Silent rs17001276 4 76877166 [T/C] NM_018115,NM_001288984,NM_001288983 SDAD1,SDAD1,SDAD1 EXON Missense_V660I,Missense_V563I,Missense_V623I rs9790644 4 76877402 [A/G] NM_018115,NM_001288984,NM_001288983 SDAD1,SDAD1,SDAD1 Silent,Silent,Silent rs2242470 4 76878688 [A/G] NM_018115,NM_001288984,NM_001288983 SDAD1,SDAD1,SDAD1 EXON Synonymous_D584D,Synonymous_D487D,Synonymous_D547D rs2242473 4 76878956 [A/G] NM_018115,NM_001288984,NM_001288983 SDAD1,SDAD1,SDAD1 Silent,Silent,Silent rs1857821 4 76881979 [A/G] NM_018115,NM_001288984,NM_001288983 SDAD1,SDAD1,SDAD1 Silent,Silent,Silent rs2271527 4 76885423 [T/C] NM_018115,NM_001288984,NM_001288983 SDAD1,SDAD1,SDAD1 Silent,Silent,Silent rs3733238 4 76902739 [A/G] NM_018115,NM_001288984,NM_001288983,NR_125906 SDAD1,SDAD1,SDAD1,LOC101928809 Silent,Silent,Silent,Silent rs10008757 4 76903036 [A/G] NM_018115,NM_001288984,NM_001288983,NR_125906 SDAD1,SDAD1,SDAD1,LOC101928809 Silent,Silent,Silent,Silent rs2869460 4 76921814 [T/C] NR_125906 LOC101928809 Silent rs10336 4 76922988 [A/G] NR_125906,NM_002416 LOC101928809,CXCL9 EXON Silent,Silent rs3733236 4 76923998 [A/G] NR_125906,NM_002416 LOC101928809,CXCL9 EXON Silent,Silent rs10031051 4 76924571 [T/C] NR_125906,NM_002416 LOC101928809,CXCL9 EXON Silent,Silent rs10031452 4 76924933 [T/C] NR_125906,NM_002416 LOC101928809,CXCL9 Silent,Silent rs1554014 4 76933534 [A/G] NM_001130017 ART3 Silent rs868007 4 76934975 [A/G] NM_001130017 ART3 Silent rs884304 4 76935263 [A/G] NM_001130017 ART3 Silent rs8878 4 76942300 [A/G] NM_001130017,NM_001565 ART3,CXCL10 EXON Silent,Silent rs35795399 4 76942677 [T/C] NM_001130017,NM_001565 ART3,CXCL10 EXON Silent,Silent rs4256246 4 76945522 [A/G] NM_001130017 ART3 Silent rs4508917 4 76946097 [A/G] NM_001130017 ART3 Silent rs12504339 4 76947304 [T/C] NM_001130017 ART3 Silent rs11097212 4 76952879 [T/C] NM_001130017 ART3 Silent rs7436646 4 76955229 [T/G] NM_001130017,NM_005409,NM_001302123 ART3,CXCL11,CXCL11 EXON Silent,Silent,Silent rs9994667 4 76955248 [A/G] NM_001130017,NM_005409,NM_001302123 ART3,CXCL11,CXCL11 EXON Silent,Silent,Silent rs10017431 4 76955406 [T/C] NM_001130017,NM_005409,NM_001302123 ART3,CXCL11,CXCL11 EXON Silent,Silent,Silent rs6532111 4 76955914 [T/C] NM_001130017,NM_005409,NM_001302123 ART3,CXCL11,CXCL11 EXON Silent,Silent,Missense_S105G rs4859415 4 76956528 [A/G] NM_001130017,NM_005409,NM_001302123 ART3,CXCL11,CXCL11 Silent,Silent,Silent rs6532114 4 76957974 [T/C] NM_001130017 ART3 Silent rs7679689 4 76963187 [A/G] NM_001130017 ART3 Silent rs11097223 4 76987496 [A/G] NM_001130017 ART3 Silent rs7693606 4 76991897 [A/G] NM_001130017 ART3 Silent rs7666094 4 76994500 [A/G] NM_001130017 ART3 Silent rs6532170 4 76995049 [T/C] NM_001130017 ART3 Silent rs4859609 4 76999197 [A/G] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 Silent,Silent,Silent rs4859418 4 76999841 [A/G] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 Silent,Silent,Silent rs17001355 4 77006193 [A/G] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 Silent,Silent,Silent rs17001357 4 77007912 [T/C] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 Silent,Silent,Silent rs6829592 4 77019581 [A/G] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 Silent,Silent,Silent rs10022137 4 77023238 [A/G] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 Silent,Silent,Silent rs17001392 4 77024354 [A/G] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 Silent,Silent,Silent rs12510869 4 77024534 [A/G] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 Silent,Silent,Silent rs11097233 4 77025136 [T/C] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 Silent,Silent,Silent rs7682766 4 77025273 [T/C] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 Silent,Silent,Silent rs7697711 4 77025368 [A/G] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 Silent,Silent,Silent rs10006380 4 77027110 [T/C] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 Silent,Silent,Silent rs6836703 4 77030147 [A/G] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 Silent,Silent,Silent rs4241583 4 77030971 [T/C] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 Silent,Silent,Silent rs1128864 4 77033590 [T/C] NM_001130017,NM_001130016,NM_001179 ART3,ART3,ART3 EXON Missense_S341L,Missense_S363L,Missense_S352L rs4859426 4 77037045 [T/C] NM_017426,NR_103782,NR_103780,NR_103781,NM_001278603 NUP54,NUP54,NUP54,NUP54,NUP54 Silent,Silent,Silent,Silent,Silent rs11944608 4 77038643 [T/C] NM_017426,NR_103782,NR_103780,NR_103781,NM_001278603 NUP54,NUP54,NUP54,NUP54,NUP54 Silent,Silent,Silent,Silent,Silent rs7657846 4 77038807 [T/C] NM_017426,NR_103782,NR_103780,NR_103781,NM_001278603 NUP54,NUP54,NUP54,NUP54,NUP54 Silent,Silent,Silent,Silent,Silent rs6532203 4 77040424 [T/C] NM_017426,NR_103782,NR_103780,NR_103781,NM_001278603 NUP54,NUP54,NUP54,NUP54,NUP54 Silent,Silent,Silent,Silent,Silent rs6532208 4 77044258 [T/C] NM_017426,NR_103782,NR_103780,NR_103781,NM_001278603 NUP54,NUP54,NUP54,NUP54,NUP54 Silent,Silent,Silent,Silent,Silent rs11736405 4 77064939 [T/C] NM_017426,NR_103782,NR_103780,NR_103781,NM_001278603 NUP54,NUP54,NUP54,NUP54,NUP54 Silent,Silent,Silent,Silent,Silent rs10008834 4 77072597 [T/C] rs1465920 4 77076451 [A/G] rs17001551 4 77082403 [A/G] NM_001204255,NM_005506 SCARB2,SCARB2 EXON Silent,Silent rs3733255 4 77082749 [T/C] NM_001204255,NM_005506 SCARB2,SCARB2 EXON Silent,Silent rs7664889 4 77087704 [T/G] NM_001204255,NM_005506 SCARB2,SCARB2 Silent,Silent rs2869851 4 77094831 [T/G] NM_001204255,NM_005506 SCARB2,SCARB2 Silent,Silent rs17001561 4 77096118 [A/G] NM_001204255,NM_005506 SCARB2,SCARB2 Silent,Silent rs3796496 4 77096220 [A/G] NM_001204255,NM_005506 SCARB2,SCARB2 Silent,Silent rs17001573 4 77099384 [A/G] NM_001204255,NM_005506 SCARB2,SCARB2 Silent,Silent rs11946079 4 77105700 [T/G] NM_001204255,NM_005506 SCARB2,SCARB2 Silent,Silent rs9994218 4 77112851 [T/C] NM_001204255,NM_005506 SCARB2,SCARB2 Silent,Silent rs17001626 4 77119942 [T/C] NM_001204255,NM_005506 SCARB2,SCARB2 Silent,Silent rs17001633 4 77120873 [A/G] NM_001204255,NM_005506 SCARB2,SCARB2 Silent,Silent rs6532244 4 77125878 [A/C] NM_001204255,NM_005506 SCARB2,SCARB2 Silent,Silent rs12508223 4 77128026 [A/G] NM_001204255,NM_005506 SCARB2,SCARB2 Silent,Silent rs894251 4 77129840 [A/G] NM_001204255,NM_005506 SCARB2,SCARB2 Silent,Silent rs9991821 4 77130285 [A/G] NM_001204255,NM_005506 SCARB2,SCARB2 Silent,Silent rs17001659 4 77131069 [T/C] NM_001204255,NM_005506 SCARB2,SCARB2 Silent,Silent rs7685696 4 77139510 [A/G] NM_001242936 FAM47E Silent rs4282210 4 77142346 [A/C] NM_001242936 FAM47E Silent rs2034004 4 77144682 [T/C] NM_001242936 FAM47E Silent rs1348205 4 77145399 [T/C] NM_001242936 FAM47E Silent rs12505005 4 77149119 [T/C] NM_001242936 FAM47E Silent rs1596116 4 77151474 [T/C] NM_001242936 FAM47E Silent rs1441904 4 77151880 [A/G] NM_001242936 FAM47E Silent rs6846983 4 77151938 [T/C] NM_001242936 FAM47E Silent rs11097297 4 77154865 [T/C] NM_001242936 FAM47E Silent rs1441922 4 77159700 [A/G] NM_001242936 FAM47E Silent rs1348206 4 77167242 [A/G] NM_001242936 FAM47E Silent rs13117238 4 77173914 [A/C] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs10856883 4 77174469 [A/C] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs717239 4 77175743 [A/G] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs7671407 4 77176552 [A/G] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs7655536 4 77176768 [T/C] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs17001726 4 77177027 [A/G] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs2289514 4 77177817 [A/G] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs6819794 4 77178379 [A/G] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs6851219 4 77179830 [T/C] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs2904221 4 77182033 [T/C] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs17308336 4 77186415 [A/C] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs3733251 4 77192838 [A/C] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E EXON Missense_K165Q,Missense_K263Q,Missense_K263Q rs3733250 4 77192868 [A/G] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E EXON Missense_E175K,Missense_E273K,Missense_E273K rs17236661 4 77196476 [T/G] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs6532316 4 77198756 [A/G] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs6812193 4 77198986 [T/C] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs964051 4 77199414 [A/C] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs1036788 4 77201487 [T/C] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E EXON Missense_T268M,Silent,Missense_T366M rs1530297 4 77202861 [A/G] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs1542096 4 77204500 [T/C] NM_001242936,NM_001242939,NM_001136570 FAM47E,FAM47E-STBD1,FAM47E Silent,Silent,Silent rs6532327 4 77208412 [T/C] NM_001242939 FAM47E-STBD1 Silent rs1508335 4 77218240 [A/G] NM_001242939 FAM47E-STBD1 Silent rs6830162 4 77219402 [T/G] NM_001242939 FAM47E-STBD1 Silent rs12506745 4 77220837 [T/G] NM_001242939 FAM47E-STBD1 Silent rs10019831 4 77222933 [A/C] NM_001242939 FAM47E-STBD1 Silent rs13104573 4 77225313 [T/C] NM_001242939 FAM47E-STBD1 Silent rs3733249 4 77227485 [A/G] NM_001242939,NM_003943 FAM47E-STBD1,STBD1 EXON Silent,Silent rs11097330 4 77227573 [A/G] NM_001242939,NM_003943 FAM47E-STBD1,STBD1 EXON Silent,Silent rs3733248 4 77231294 [A/C] NM_001242939,NM_003943 FAM47E-STBD1,STBD1 EXON Silent,Silent rs17001772 4 77231611 [A/G] NM_001242939,NM_003943 FAM47E-STBD1,STBD1 EXON Silent,Silent rs7658585 4 77252196 [T/C] NM_001042784 CCDC158 Silent rs1911737 4 77262103 [T/C] NM_001042784 CCDC158 Silent rs17001824 4 77288833 [T/C] NM_001042784 CCDC158 EXON Missense_E482K rs11097338 4 77289952 [A/G] NM_001042784 CCDC158 Silent rs17001890 4 77305346 [A/G] NM_001042784 CCDC158 EXON Synonymous_H207H rs2136050 4 77309789 [A/G] NM_001042784 CCDC158 Silent rs6857452 4 77317124 [T/C] NM_001042784 CCDC158 Silent rs4272041 4 77330682 [A/G] rs17001949 4 77343148 [T/C] rs12108362 4 77343257 [T/C] rs6827818 4 77355639 [A/G] rs10000169 4 77356246 [T/C] rs10006043 4 77357747 [T/C] NM_020859 SHROOM3 Silent rs11097356 4 77359677 [T/C] NM_020859 SHROOM3 Silent rs11737407 4 77359789 [A/G] NM_020859 SHROOM3 Silent rs13102317 4 77362699 [T/C] NM_020859 SHROOM3 Silent rs7677847 4 77364126 [A/G] NM_020859 SHROOM3 Silent rs4859673 4 77364799 [A/G] NM_020859 SHROOM3 Silent rs1398016 4 77367688 [A/G] NM_020859 SHROOM3 Silent rs17001970 4 77370038 [T/C] NM_020859 SHROOM3 Silent rs4859678 4 77386372 [T/G] NM_020859 SHROOM3 Silent rs1511817 4 77386678 [A/G] NM_020859 SHROOM3 Silent rs6843293 4 77392092 [A/G] NM_020859 SHROOM3 Silent rs4129337 4 77397585 [T/C] NM_020859 SHROOM3 Silent rs10213666 4 77397830 [T/C] NM_020859 SHROOM3 Silent rs10032549 4 77398015 [A/G] NM_020859 SHROOM3 Silent rs6532418 4 77408781 [A/G] NM_020859 SHROOM3 Silent rs7654754 4 77409795 [A/G] NM_020859 SHROOM3 Silent rs4859682 4 77410318 [A/C] NM_020859 SHROOM3 Silent rs12651108 4 77411996 [T/C] NM_020859 SHROOM3 Silent rs2068064 4 77417060 [A/G] NM_020859 SHROOM3 Silent rs13152154 4 77417756 [T/C] NM_020859 SHROOM3 Silent rs13106227 4 77418681 [A/G] NM_020859 SHROOM3 Silent rs1986734 4 77420784 [T/C] NM_020859 SHROOM3 Silent rs7696372 4 77424167 [T/C] NM_020859 SHROOM3 Silent rs4452451 4 77430136 [T/C] NM_020859 SHROOM3 Silent rs17254217 4 77430773 [T/C] NM_020859 SHROOM3 Silent rs17002031 4 77432584 [A/G] NM_020859 SHROOM3 Silent rs4859688 4 77439979 [T/C] NM_020859 SHROOM3 Silent rs4371638 4 77440267 [T/C] NM_020859 SHROOM3 Silent rs9999448 4 77441772 [A/G] NM_020859 SHROOM3 Silent rs10002311 4 77442504 [A/C] NM_020859 SHROOM3 Silent rs6848817 4 77446681 [A/C] NM_020859 SHROOM3 Silent rs13151434 4 77448199 [A/G] NM_020859 SHROOM3 Silent rs6810716 4 77452151 [T/C] NM_020859 SHROOM3 Silent rs10023611 4 77454497 [A/G] NM_020859 SHROOM3 Silent rs10024176 4 77455181 [A/G] NM_020859 SHROOM3 Silent rs9999005 4 77456093 [T/C] NM_020859 SHROOM3 Silent rs6819880 4 77458649 [A/G] NM_020859 SHROOM3 Silent rs11097403 4 77459600 [T/G] NM_020859 SHROOM3 Silent rs6817593 4 77461011 [T/C] NM_020859 SHROOM3 Silent rs17002070 4 77462390 [T/C] NM_020859 SHROOM3 Silent rs17002074 4 77464016 [A/G] NM_020859 SHROOM3 Silent rs10027450 4 77465074 [T/C] NM_020859 SHROOM3 Silent rs9996716 4 77467624 [A/G] NM_020859 SHROOM3 Silent rs11932470 4 77468196 [A/G] NM_020859 SHROOM3 Silent rs3923380 4 77468594 [A/C] NM_020859 SHROOM3 Silent rs6532473 4 77469221 [A/C] NM_020859 SHROOM3 Silent rs10005964 4 77470300 [A/G] NM_020859 SHROOM3 Silent rs13120833 4 77471116 [T/C] NM_020859 SHROOM3 Silent rs4380545 4 77484202 [A/C] NM_020859 SHROOM3 Silent rs7687284 4 77487977 [T/G] NM_020859 SHROOM3 Silent rs6824297 4 77492155 [T/G] NM_020859 SHROOM3 Silent rs4380546 4 77497756 [A/G] NM_020859 SHROOM3 Silent rs17002091 4 77500947 [A/G] NM_020859 SHROOM3 Silent rs12503111 4 77503120 [T/G] NM_020859 SHROOM3 Silent rs13148163 4 77504400 [T/C] NM_020859 SHROOM3 Silent rs13140663 4 77507863 [A/C] NM_020859 SHROOM3 Silent rs4859453 4 77515370 [A/G] NM_020859 SHROOM3 Silent rs6846198 4 77517128 [A/G] NM_020859 SHROOM3 Silent rs12501546 4 77521826 [A/G] NM_020859 SHROOM3 Silent rs17322390 4 77523129 [A/G] NM_020859 SHROOM3 Silent rs12640320 4 77531337 [A/C] NM_020859 SHROOM3 Silent rs11734813 4 77540746 [A/G] NM_020859 SHROOM3 Silent rs7669852 4 77542398 [A/G] NM_020859 SHROOM3 Silent rs13104324 4 77543863 [A/G] NM_020859 SHROOM3 Silent rs4330370 4 77545018 [T/G] NM_020859 SHROOM3 Silent rs10223020 4 77547939 [A/G] NM_020859 SHROOM3 Silent rs7695340 4 77551310 [T/C] NM_020859 SHROOM3 Silent rs11722153 4 77551856 [T/C] NM_020859 SHROOM3 Silent rs4582178 4 77552782 [A/G] NM_020859 SHROOM3 Silent rs4859699 4 77555857 [A/G] NM_020859 SHROOM3 Silent rs17322529 4 77560811 [A/G] NM_020859 SHROOM3 Silent rs4859456 4 77562958 [T/C] NM_020859 SHROOM3 Silent rs17002139 4 77576402 [A/G] NM_020859 SHROOM3 Silent rs11727631 4 77576975 [T/C] NM_020859 SHROOM3 Silent rs13130505 4 77594917 [T/C] NM_020859 SHROOM3 Silent rs1493363 4 77601715 [A/G] NM_020859 SHROOM3 Silent rs2172505 4 77612903 [A/C] NM_020859 SHROOM3 Silent rs344117 4 77619296 [T/C] NM_020859 SHROOM3 Silent rs2035945 4 77621705 [A/G] NM_020859 SHROOM3 Silent rs13121538 4 77626887 [T/C] NM_020859 SHROOM3 Silent rs6849066 4 77634028 [A/G] NM_020859 SHROOM3 Silent rs10013334 4 77636643 [T/G] NM_020859 SHROOM3 Silent rs344122 4 77637502 [A/C] NM_020859 SHROOM3 Silent rs11734394 4 77640617 [A/G] NM_020859 SHROOM3 Silent rs344130 4 77647590 [T/C] NM_020859 SHROOM3 Silent rs11735775 4 77649374 [T/C] NM_020859 SHROOM3 Silent rs724096 4 77650897 [A/C] NM_020859 SHROOM3 Silent rs344135 4 77652219 [T/C] NM_020859 SHROOM3 Silent rs344140 4 77660162 [C/G] NM_020859 SHROOM3 EXON Missense_G279A rs344141 4 77660731 [C/G] NM_020859 SHROOM3 EXON Missense_P469A rs4859711 4 77665279 [A/G] NM_020859 SHROOM3 Silent rs10518155 4 77666254 [T/C] NM_020859 SHROOM3 Silent rs10022778 4 77669728 [A/G] NM_020859 SHROOM3 Silent rs3733242 4 77675505 [T/C] NM_020859 SHROOM3 EXON Missense_P1290L rs17002200 4 77680526 [A/G] NM_020859 SHROOM3 Silent rs13113476 4 77684099 [A/G] NM_020859 SHROOM3 Silent rs13129187 4 77688152 [T/C] NM_020859 SHROOM3 Silent rs10518156 4 77695104 [T/C] NM_020859 SHROOM3 Silent rs4859461 4 77695349 [T/C] NM_020859 SHROOM3 Silent rs7661695 4 77701909 [A/G] NM_020859 SHROOM3 EXON Silent rs716525 4 77717083 [T/C] rs344108 4 77718624 [A/G] rs11097519 4 77719779 [A/G] rs344107 4 77719812 [T/C] rs17324961 4 77719935 [A/G] rs12646332 4 77720135 [T/C] rs9998681 4 77721997 [A/G] rs12054540 4 77724484 [A/G] rs6821442 4 77725026 [A/G] rs17002218 4 77725091 [T/C] rs6853653 4 77725242 [T/C] rs6840749 4 77726159 [A/G] rs13124337 4 77727505 [A/G] rs7663030 4 77730260 [A/G] rs2172496 4 77734939 [A/G] rs11938295 4 77739602 [A/G] rs17002240 4 77742277 [A/G] rs13152105 4 77743520 [T/C] rs1493305 4 77747798 [A/C] rs9307199 4 77751647 [A/G] rs11097539 4 77754140 [A/G] rs12500486 4 77754619 [A/C] rs12500522 4 77754699 [A/G] rs4859466 4 77763831 [T/C] rs1994854 4 77767645 [T/C] rs1108255 4 77768463 [A/G] rs17260538 4 77770388 [T/C] rs17002253 4 77771345 [T/C] rs10518160 4 77772872 [T/G] rs4859723 4 77773437 [A/G] rs6829573 4 77773610 [A/G] rs344837 4 77778487 [T/C] rs6835485 4 77780095 [T/G] rs17261150 4 77783243 [A/G] rs17261171 4 77783901 [A/G] rs7693322 4 77784395 [T/C] rs11727571 4 77784500 [A/G] rs401382 4 77784736 [T/C] rs6821290 4 77785183 [T/G] rs6810774 4 77792007 [A/C] rs237616 4 77793015 [T/G] rs1472201 4 77793375 [A/G] rs6532676 4 77793829 [T/C] rs6828780 4 77799849 [A/G] rs2132766 4 77800625 [T/C] rs6532686 4 77804009 [T/C] rs7667074 4 77806097 [T/C] rs6853383 4 77812990 [T/C] rs11947481 4 77814209 [A/G] rs4859725 4 77815545 [T/C] NM_001029870 SOWAHB EXON Silent rs2703130 4 77817874 [T/G] NM_001029870 SOWAHB EXON Missense_P377T rs2645683 4 77820005 [A/G] rs2703115 4 77824442 [T/C] rs2703147 4 77831307 [A/G] rs12331206 4 77836665 [A/C] rs6847460 4 77851537 [A/C] rs2703137 4 77854979 [T/G] rs1874565 4 77857753 [T/C] rs11722689 4 77863211 [T/C] rs2645651 4 77864488 [T/C] rs2703139 4 77864911 [T/C] rs4859727 4 77866648 [T/C] rs2645656 4 77868088 [T/C] rs10009464 4 77868340 [T/C] rs873090 4 77871016 [T/G] NM_001306147,NM_018243 SEPT11,SEPT11 EXON Silent,Silent rs10213389 4 77878392 [T/G] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs12650893 4 77878521 [A/G] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs2703111 4 77880892 [T/C] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs17002297 4 77882431 [T/C] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs1472399 4 77886046 [T/C] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs2132768 4 77894220 [A/G] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs2703109 4 77894399 [A/G] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs883698 4 77915665 [A/G] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs6836567 4 77916705 [A/C] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs10006616 4 77917535 [A/C] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs7692644 4 77918966 [A/G] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs878729 4 77921005 [T/C] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs6826681 4 77927538 [A/G] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs1532449 4 77934171 [A/G] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs4859731 4 77943171 [T/C] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs17002332 4 77947153 [T/C] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs17002334 4 77949278 [A/G] NM_001306147,NM_018243 SEPT11,SEPT11 Silent,Silent rs1127595 4 77958765 [A/G] NM_001306147,NM_018243 SEPT11,SEPT11 EXON Silent,Silent rs10000606 4 77961377 [A/G] rs4252949 4 77969298 [T/C] NM_001348138,NM_001348140,NM_001348132,NM_001348135,NM_001348134,NM_001348133,NM_001348136,NM_001348137,NM_001348139,NM_006835 CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4252948 4 77969851 [A/G] NM_001348138,NM_001348140,NM_001348132,NM_001348135,NM_001348134,NM_001348133,NM_001348136,NM_001348137,NM_001348139,NM_006835 CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4252931 4 77972491 [A/G] NM_001348138,NM_001348140,NM_001348132,NM_001348135,NM_001348134,NM_001348133,NM_001348136,NM_001348137,NM_001348139,NM_006835 CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4241599 4 77974545 [T/C] NM_001348138,NM_001348140,NM_001348132,NM_001348135,NM_001348134,NM_001348133,NM_001348136,NM_001348137,NM_001348139,NM_006835 CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4252913 4 77974776 [A/G] NM_001348138,NM_001348140,NM_001348132,NM_001348135,NM_001348134,NM_001348133,NM_001348136,NM_001348137,NM_001348139,NM_006835 CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4252901 4 77977235 [T/C] NM_001348138,NM_001348140,NM_001348132,NM_001348135,NM_001348134,NM_001348133,NM_001348136,NM_001348137,NM_001348139,NM_006835 CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI EXON Synonymous_V8V,Synonymous_V113V,Synonymous_V113V,Silent,Synonymous_V99V,Synonymous_V113V,Synonymous_V70V,Silent,Silent,Synonymous_V113V rs4252845 4 77984155 [A/C] NM_001348138,NM_001348140,NM_001348132,NM_001348135,NM_001348134,NM_001348133,NM_001348136,NM_001348137,NM_001348139,NM_006835 CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4252828 4 77986728 [T/C] NM_001348138,NM_001348140,NM_001348132,NM_001348135,NM_001348134,NM_001348133,NM_001348136,NM_001348137,NM_001348139,NM_006835 CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4241602 4 77987351 [A/G] NM_001348138,NM_001348140,NM_001348132,NM_001348135,NM_001348134,NM_001348133,NM_001348136,NM_001348137,NM_001348139,NM_006835 CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1048417 4 77992014 [T/G] NM_001348138,NM_001348140,NM_001348132,NM_001348135,NM_001348134,NM_001348133,NM_001348136,NM_001348137,NM_001348139,NM_006835 CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4252784 4 77994502 [T/C] NM_001348138,NM_001348140,NM_001348132,NM_001348135,NM_001348134,NM_001348133,NM_001348136,NM_001348137,NM_001348139,NM_006835 CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4252782 4 77994734 [T/C] NM_001348138,NM_001348140,NM_001348132,NM_001348135,NM_001348134,NM_001348133,NM_001348136,NM_001348137,NM_001348139,NM_006835 CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4252775 4 77995574 [T/C] NM_001348138,NM_001348140,NM_001348132,NM_001348135,NM_001348134,NM_001348133,NM_001348136,NM_001348137,NM_001348139,NM_006835 CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI,CCNI Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4502705 4 78004668 [A/G] rs11097670 4 78016353 [T/C] rs10017180 4 78017533 [A/G] rs4518273 4 78019799 [A/G] rs4461545 4 78022904 [A/G] rs10856952 4 78040544 [T/C] rs11097684 4 78045685 [A/G] rs4272042 4 78053975 [A/G] rs7659891 4 78063308 [A/G] rs4382065 4 78064766 [A/C] rs4518274 4 78069066 [T/C] rs6849534 4 78073655 [A/C] rs10010725 4 78075622 [A/G] rs4150031 4 78077235 [T/G] rs4150050 4 78079695 [T/G] NM_004354 CCNG2 EXON Missense_L4V rs4150052 4 78079772 [A/G] NM_004354 CCNG2 EXON Synonymous_E29E rs4150074 4 78083125 [T/G] NM_004354 CCNG2 Silent rs4150084 4 78084904 [A/G] NM_004354 CCNG2 Silent rs881997 4 78098806 [T/C] rs6848898 4 78103458 [A/G] rs28503908 4 78106123 [T/C] rs6822800 4 78106441 [A/C] rs11097730 4 78115334 [T/C] rs10025838 4 78120747 [A/C] rs6840204 4 78121828 [A/G] rs11943130 4 78123574 [T/C] rs4859756 4 78124348 [T/G] rs6840915 4 78129387 [T/G] rs11937061 4 78136933 [T/G] rs11937096 4 78137036 [A/G] rs1477314 4 78137234 [T/C] rs1009141 4 78139160 [T/C] rs716024 4 78145293 [A/C] rs11097744 4 78153905 [T/C] rs28735825 4 78154524 [T/C] rs2009091 4 78161220 [A/G] rs7661051 4 78161257 [A/G] rs4241605 4 78161506 [T/C] rs13144211 4 78161745 [A/G] rs2865830 4 78161843 [T/C] rs2009261 4 78161984 [T/C] rs10491462 4 78162739 [T/C] rs6835713 4 78168932 [T/G] rs4450960 4 78174854 [T/C] rs736601 4 78181653 [A/G] rs17643945 4 78194110 [T/C] rs11732260 4 78203795 [A/G] rs17396361 4 78210296 [T/C] rs4859484 4 78211866 [A/G] rs6846129 4 78216136 [A/G] rs7664426 4 78227999 [A/C] rs17002563 4 78229562 [T/C] rs4859782 4 78231196 [T/C] rs4859487 4 78237955 [A/G] rs9307268 4 78239827 [A/G] rs17002564 4 78268226 [A/G] rs11726925 4 78268641 [T/C] rs11936421 4 78270126 [A/G] rs10023142 4 78271822 [T/G] rs1559121 4 78276420 [T/G] rs10034168 4 78280329 [T/G] rs7375525 4 78291269 [A/G] rs17002597 4 78291808 [T/C] rs17002600 4 78291876 [A/G] rs2866281 4 78292049 [A/G] rs12500776 4 78292203 [A/G] rs17002607 4 78293321 [A/C] rs4859824 4 78293878 [A/G] rs17002610 4 78294359 [A/G] rs1806786 4 78307791 [T/C] rs12502190 4 78308601 [A/G] rs1550600 4 78326294 [A/G] rs7682075 4 78327333 [A/G] rs1372784 4 78328101 [A/G] rs6533029 4 78329877 [A/G] rs1372786 4 78330433 [T/C] rs17002672 4 78333798 [T/C] rs2197167 4 78334386 [T/G] rs6841674 4 78334882 [T/C] rs11931577 4 78335569 [T/C] rs13138737 4 78336408 [T/C] rs11721695 4 78339282 [T/C] rs11726795 4 78339441 [A/G] rs6851181 4 78341476 [A/G] rs12649862 4 78343820 [A/G] rs34107162 4 78344132 [A/G] rs17002676 4 78346794 [T/G] rs10020156 4 78349135 [T/C] rs1442696 4 78351064 [A/G] rs1073284 4 78351923 [T/C] rs4280762 4 78352799 [T/C] rs12510042 4 78355165 [A/C] rs11939449 4 78356862 [T/C] rs7685130 4 78366298 [A/G] rs1348299 4 78373045 [T/C] rs6831175 4 78389293 [T/C] rs12501028 4 78391533 [T/C] rs1596230 4 78396544 [A/G] rs11735457 4 78404249 [A/G] rs17002698 4 78407364 [T/C] rs12510689 4 78413360 [T/G] rs17002700 4 78417537 [T/G] rs10518178 4 78419683 [T/C] rs10518177 4 78420568 [T/C] rs1442691 4 78424381 [T/C] rs2053526 4 78426029 [A/G] rs17002713 4 78432340 [T/C] rs17002716 4 78448018 [A/G] NM_006419 CXCL13 Silent rs17406477 4 78456502 [A/G] NM_006419 CXCL13 Silent rs1077234 4 78459361 [A/G] NM_006419 CXCL13 Silent rs1596231 4 78464698 [A/G] NM_006419 CXCL13 Silent rs355679 4 78478506 [T/G] NM_006419 CXCL13 Silent rs355667 4 78495883 [G/C] NM_006419 CXCL13 Silent rs189587 4 78500085 [A/G] NM_006419 CXCL13 Silent rs10009964 4 78500673 [T/C] NM_006419 CXCL13 Silent rs355686 4 78505372 [T/C] NM_006419 CXCL13 Silent rs355687 4 78505578 [T/C] NM_006419 CXCL13 Silent rs355689 4 78507797 [T/C] NM_006419 CXCL13 Silent rs2584819 4 78509804 [A/G] NM_006419 CXCL13 Silent rs920666 4 78511203 [T/C] NM_006419 CXCL13 Silent rs1867106 4 78511756 [A/C] NM_006419 CXCL13 Silent rs17002731 4 78513987 [A/G] NM_006419 CXCL13 Silent rs171388 4 78521525 [T/C] NM_006419 CXCL13 Silent rs355661 4 78523092 [A/G] NM_006419 CXCL13 Silent rs2903289 4 78530068 [A/G] NM_006419 CXCL13 Silent rs1052563 4 78532232 [T/C] NM_006419 CXCL13 EXON Silent rs10022693 4 78533252 [T/C] rs1566485 4 78542597 [A/C] rs9993375 4 78544132 [A/G] rs17416271 4 78544487 [T/C] rs2173755 4 78549559 [T/C] rs2866441 4 78555443 [T/C] rs2866442 4 78558585 [T/G] rs972755 4 78562040 [A/G] rs4859868 4 78562573 [A/G] rs17002774 4 78573559 [T/C] rs17416515 4 78597444 [A/G] rs10009981 4 78598313 [T/C] rs17002777 4 78599936 [A/G] rs10049568 4 78603333 [T/C] rs958617 4 78605369 [A/G] rs17002781 4 78624604 [A/G] rs2866690 4 78637265 [A/G] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L EXON Silent,Silent,Silent,Silent rs3205281 4 78638491 [T/C] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L EXON Silent,Silent,Silent,Silent rs2134048 4 78638730 [T/C] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L EXON Silent,Silent,Silent,Silent rs13104947 4 78643791 [A/C] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L Silent,Silent,Silent,Silent rs17002797 4 78643947 [T/G] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L Silent,Silent,Silent,Silent rs17448771 4 78655778 [A/G] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L Silent,Silent,Silent,Silent rs10005741 4 78682349 [T/C] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L Silent,Silent,Silent,Silent rs10005935 4 78682581 [T/G] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L Silent,Silent,Silent,Silent rs9307306 4 78697786 [T/C] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L Silent,Silent,Silent,Silent rs17002804 4 78708696 [A/C] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L Silent,Silent,Silent,Silent rs4859878 4 78713254 [T/C] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L Silent,Silent,Silent,Silent rs4859879 4 78722315 [T/C] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L Silent,Silent,Silent,Silent rs11727750 4 78729261 [T/C] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L Silent,Silent,Silent,Silent rs10222901 4 78732149 [T/G] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L Silent,Silent,Silent,Silent rs1587563 4 78734563 [A/G] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L Silent,Silent,Silent,Silent rs1814033 4 78738089 [A/C] NM_001365007,NM_001286790,NM_001365006,NM_144571 CNOT6L,CNOT6L,CNOT6L,CNOT6L Silent,Silent,Silent,Silent rs4365752 4 78747771 [T/C] rs17002816 4 78748751 [T/C] rs1996740 4 78748977 [A/G] rs2866688 4 78749042 [A/G] rs10518182 4 78757015 [T/G] rs6817305 4 78776883 [A/G] rs6827822 4 78784433 [T/C] NM_020236 MRPL1 Silent rs10026176 4 78794541 [T/C] NM_020236 MRPL1 Silent rs6849145 4 78806253 [A/C] NM_020236 MRPL1 Silent rs6816113 4 78817124 [A/C] NM_020236 MRPL1 Silent rs10005531 4 78820513 [T/G] NM_020236 MRPL1 Silent rs7671941 4 78834863 [T/C] NM_020236 MRPL1 Silent rs4859512 4 78840447 [T/C] NM_020236 MRPL1 Silent rs7439347 4 78841872 [T/G] NM_020236 MRPL1 Silent rs924684 4 78849088 [A/G] NM_020236 MRPL1 Silent rs7687500 4 78854942 [T/C] NM_020236 MRPL1 Silent rs4577601 4 78858515 [A/G] NM_020236 MRPL1 Silent rs17450279 4 78868343 [A/G] NM_020236 MRPL1 Silent rs13101418 4 78875974 [T/C] rs7699718 4 78879461 [T/C] rs12504644 4 78889803 [T/C] rs7683766 4 78889868 [A/G] rs17450634 4 78909717 [A/G] rs6533374 4 78915841 [A/C] rs4859894 4 78918906 [T/C] rs12641050 4 78924968 [T/C] rs2036455 4 78934172 [A/G] rs11940556 4 78937771 [T/C] rs7667122 4 78947327 [T/C] rs1546318 4 78949372 [T/G] rs1875649 4 78967046 [T/C] rs1502877 4 78968798 [T/G] rs7696815 4 78970022 [T/C] rs7656678 4 78970864 [T/C] rs4859904 4 78973933 [T/C] rs2036460 4 78974336 [A/G] rs7677984 4 78974867 [A/C] rs1910301 4 78975137 [A/G] rs28363906 4 78978198 [A/G] rs1502887 4 78983383 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs10518184 4 78984082 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs4859905 4 78987157 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 EXON Missense_D32G,Missense_D32G rs873455 4 78989939 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs4591635 4 78991030 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs9284617 4 78992568 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17002916 4 78995887 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17002919 4 78996420 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs4241622 4 78997515 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs6843142 4 79002597 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs7699864 4 79023544 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs10518187 4 79025681 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs6847174 4 79033428 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs6845871 4 79048490 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs2078481 4 79052851 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs1317018 4 79056713 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17002971 4 79061464 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs6848061 4 79073650 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17420118 4 79075964 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs10518193 4 79077273 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs9307352 4 79081466 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs10518194 4 79083490 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs9284618 4 79083751 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs10518195 4 79093399 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs2903455 4 79095407 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs4309859 4 79095777 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs7688981 4 79099678 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17003025 4 79103687 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17003028 4 79104112 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17003031 4 79105219 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs11098085 4 79108589 [A/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs1996389 4 79118533 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs7695549 4 79120256 [A/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17003043 4 79122800 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17003046 4 79125844 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs10518188 4 79126005 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs6533529 4 79127114 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs7438530 4 79129619 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs2866993 4 79136032 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs7686101 4 79138857 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs11941469 4 79148953 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs11725082 4 79158128 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17003070 4 79158316 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs1869646 4 79163162 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs13117388 4 79173335 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs1017650 4 79176015 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs10010118 4 79176094 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs12510741 4 79177408 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs1378240 4 79185019 [A/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs1840392 4 79185399 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs13108102 4 79198744 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs6815945 4 79205747 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs6839334 4 79205752 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs967635 4 79207784 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs13136648 4 79209463 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17456396 4 79210546 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs1484344 4 79212910 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17003113 4 79219046 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs12511889 4 79222347 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs345528 4 79229302 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 EXON Synonymous_R539R,Synonymous_R539R rs1385133 4 79231933 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs345518 4 79236212 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs345515 4 79238448 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs345514 4 79238649 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 EXON Synonymous_H649H,Synonymous_H649H rs17003125 4 79239546 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs345513 4 79240063 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 EXON Missense_D687G,Missense_D687G rs345512 4 79240131 [A/C] NM_025074,NM_001166133 FRAS1,FRAS1 EXON Missense_I710L,Missense_I710L rs345510 4 79241357 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs11724700 4 79245028 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs391275 4 79248325 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs168282 4 79254058 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs388825 4 79256785 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs396790 4 79258862 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 EXON Synonymous_P771P,Synonymous_P771P rs371923 4 79259734 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs429977 4 79261323 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs454598 4 79261745 [A/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs13123934 4 79262501 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs366463 4 79262696 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs10015470 4 79265536 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs1454890 4 79266563 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs368313 4 79268802 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs2008485 4 79276588 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17003157 4 79281934 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs345545 4 79283643 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs6833805 4 79284428 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs6835769 4 79284694 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 EXON Missense_A817V,Missense_A817V rs6837091 4 79285958 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs2903468 4 79286553 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs11932185 4 79287631 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs345542 4 79288238 [A/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs11098160 4 79291535 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs7687731 4 79295156 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17003169 4 79296723 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs923019 4 79300173 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs923017 4 79300280 [A/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs12512164 4 79300993 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 EXON Missense_E1136K,Missense_E1136K rs7679527 4 79302857 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs1471748 4 79303200 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs10033307 4 79304226 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17003174 4 79304598 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs12644161 4 79306297 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs869349 4 79307872 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs10016220 4 79308446 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs12651417 4 79319428 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs1484334 4 79335148 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs1484332 4 79339332 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs989028 4 79344115 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs6825981 4 79346759 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs2054722 4 79350115 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs17427362 4 79350769 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs6813102 4 79351560 [T/C] NM_025074,NM_001166133 FRAS1,FRAS1 EXON Missense_P1653L,Missense_P1653L rs2170899 4 79359885 [T/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs2035510 4 79362209 [A/G] NM_025074,NM_001166133 FRAS1,FRAS1 Silent,Silent rs7671908 4 79372272 [A/G] NM_025074 FRAS1 Silent rs10026662 4 79372856 [A/C] NM_025074 FRAS1 Silent rs753752 4 79372930 [T/C] NM_025074 FRAS1 EXON Synonymous_H2156H rs17003249 4 79376446 [A/G] NM_025074 FRAS1 Silent rs2627654 4 79378809 [A/G] NM_025074 FRAS1 Silent rs13123710 4 79385632 [T/C] NM_025074 FRAS1 EXON Synonymous_V2308V rs6851427 4 79385719 [A/G] NM_025074 FRAS1 EXON Synonymous_A2337A rs7684722 4 79387464 [A/G] NM_025074 FRAS1 EXON Missense_K2378E rs1496602 4 79391036 [T/C] NM_025074 FRAS1 Silent rs13114980 4 79391988 [A/G] NM_025074 FRAS1 Silent rs6817204 4 79395294 [A/G] NM_025074 FRAS1 Silent rs1995060 4 79398481 [T/C] NM_025074 FRAS1 Silent rs12509281 4 79401434 [A/G] NM_025074 FRAS1 Silent rs6817436 4 79402546 [T/C] NM_025074 FRAS1 Silent rs17409828 4 79402688 [A/G] NM_025074 FRAS1 Silent rs924149 4 79403747 [A/C] NM_025074 FRAS1 Silent rs7686157 4 79409610 [T/C] NM_025074 FRAS1 Silent rs1496604 4 79409899 [T/C] NM_025074 FRAS1 Silent rs6825278 4 79416629 [T/C] NM_025074 FRAS1 Silent rs4975132 4 79420616 [A/G] NM_025074 FRAS1 Silent rs11933630 4 79421011 [T/G] NM_025074 FRAS1 EXON Synonymous_R3084R rs1496585 4 79421698 [A/G] NM_025074 FRAS1 Silent rs4975135 4 79422054 [A/G] NM_025074 FRAS1 Silent rs2867447 4 79422073 [A/G] NM_025074 FRAS1 Silent rs11940606 4 79431352 [A/G] NM_025074 FRAS1 Silent rs3792608 4 79434343 [A/G] NM_025074 FRAS1 Silent rs6844368 4 79439935 [T/G] NM_025074 FRAS1 Silent rs7669587 4 79442003 [T/G] NM_025074 FRAS1 Silent rs931605 4 79443837 [A/T] NM_025074 FRAS1 EXON Missense_E3561D rs931606 4 79443850 [A/G] NM_025074 FRAS1 EXON Missense_V3566I rs10028215 4 79445470 [A/G] NM_025074 FRAS1 Silent rs4975137 4 79450373 [A/G] NM_025074 FRAS1 Silent rs1496594 4 79454315 [T/C] NM_025074 FRAS1 Silent rs4975139 4 79455733 [T/C] NM_025074 FRAS1 EXON Synonymous_L3686L rs12639791 4 79456303 [A/G] NM_025074 FRAS1 Silent rs6533756 4 79458537 [A/C] NM_025074 FRAS1 Silent rs7689740 4 79458598 [A/G] NM_025074 FRAS1 Silent rs17003321 4 79464092 [A/G] NM_025074 FRAS1 EXON Silent rs3811747 4 79464432 [T/C] NM_025074 FRAS1 EXON Silent rs3749482 4 79465559 [A/G] rs28406138 4 79472339 [A/G] rs931602 4 79485876 [A/G] NM_005139 ANXA3 Silent rs6533780 4 79487060 [A/C] NM_005139 ANXA3 Silent rs4975147 4 79488270 [A/G] NM_005139 ANXA3 Silent rs5945 4 79494430 [T/C] NM_005139 ANXA3 Silent rs7656476 4 79505884 [T/C] NM_005139 ANXA3 Silent rs7679218 4 79506864 [T/G] NM_005139 ANXA3 Silent rs2867461 4 79513215 [A/G] NM_005139 ANXA3 Silent rs17003381 4 79516445 [A/G] NM_005139 ANXA3 Silent rs17003384 4 79520548 [T/C] NM_005139 ANXA3 Silent rs1466765 4 79522208 [T/C] NM_005139 ANXA3 Silent rs6844356 4 79522598 [T/C] NM_005139 ANXA3 Silent rs6533821 4 79524420 [T/C] NM_005139 ANXA3 Silent rs5942 4 79525404 [A/G] NM_005139 ANXA3 Silent rs7661370 4 79528957 [T/G] NM_005139 ANXA3 Silent rs10029214 4 79529206 [A/G] NM_005139 ANXA3 Silent rs5950 4 79531202 [T/C] NM_005139 ANXA3 Silent rs4612 4 79531308 [T/C] NM_005139 ANXA3 EXON Silent rs6825328 4 79537360 [T/C] rs12643488 4 79546144 [A/G] rs7680766 4 79552176 [T/G] rs11736602 4 79572289 [T/C] NR_038308,NR_038304,NR_038305,NR_038307,NR_038303,NR_038306 LINC01094,LINC01094,LINC01094,LINC01094,LINC01094,LINC01094 Silent,Silent,Silent,Silent,Silent,Silent rs11942573 4 79584433 [A/G] NR_038308,NR_038304,NR_038305,NR_038307,NR_038303,NR_038306 LINC01094,LINC01094,LINC01094,LINC01094,LINC01094,LINC01094 Silent,Silent,Silent,Silent,Silent,Silent rs10007186 4 79589045 [T/C] NR_038308,NR_038304,NR_038305,NR_038307,NR_038303,NR_038306 LINC01094,LINC01094,LINC01094,LINC01094,LINC01094,LINC01094 Silent,Silent,Silent,Silent,Silent,Silent rs7698993 4 79590729 [A/G] NR_038308,NR_038304,NR_038305,NR_038307,NR_038303,NR_038306 LINC01094,LINC01094,LINC01094,LINC01094,LINC01094,LINC01094 Silent,Silent,Silent,Silent,Silent,Silent rs1134124 4 79602718 [A/G] NR_038308,NR_038304,NR_038305,NR_038307,NR_038303,NR_038306 LINC01094,LINC01094,LINC01094,LINC01094,LINC01094,LINC01094 EXON Silent,Silent,Silent,Silent,Silent,Silent rs4619914 4 79612009 [A/G] rs1834519 4 79616556 [T/C] rs1346145 4 79625240 [T/C] rs7694971 4 79629350 [T/G] rs1966537 4 79634522 [T/G] rs6811782 4 79645394 [T/C] rs11724233 4 79646371 [T/G] rs12648219 4 79655286 [A/G] rs12644278 4 79685513 [A/G] rs13138117 4 79689207 [T/C] rs1816184 4 79700596 [A/G] NM_198892,NM_017593 BMP2K,BMP2K Silent,Silent rs1426138 4 79701528 [A/G] NM_198892,NM_017593 BMP2K,BMP2K Silent,Silent rs10518204 4 79710989 [T/C] NM_198892,NM_017593 BMP2K,BMP2K Silent,Silent rs3775518 4 79720870 [T/C] NM_198892,NM_017593 BMP2K,BMP2K Silent,Silent rs10518205 4 79800080 [A/G] NM_198892,NM_017593 BMP2K,BMP2K EXON Silent,Synonymous_Q662Q rs6830661 4 79813622 [T/C] NM_198892 BMP2K Silent rs17003488 4 79824233 [A/C] NM_198892 BMP2K Silent rs12649750 4 79832509 [A/C] NM_198892 BMP2K EXON Synonymous_P936P rs7682647 4 79832815 [A/C] NM_198892 BMP2K EXON Synonymous_I1038I rs17008951 4 79834326 [T/C] rs3811766 4 79840498 [T/G] NR_146465,NR_146463,NR_146464,NM_001350106,NM_001040202,NR_146462,NM_001350105 PAQR3,PAQR3,PAQR3,PAQR3,PAQR3,PAQR3,PAQR3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1564458 4 79840956 [A/G] NR_146465,NR_146463,NR_146464,NM_001350106,NM_001040202,NR_146462,NM_001350105 PAQR3,PAQR3,PAQR3,PAQR3,PAQR3,PAQR3,PAQR3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13108247 4 79845007 [A/C] NR_146465,NR_146463,NR_146464,NM_001350106,NM_001040202,NR_146462,NM_001350105 PAQR3,PAQR3,PAQR3,PAQR3,PAQR3,PAQR3,PAQR3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7664339 4 79862591 [T/C] rs9993426 4 79875172 [A/C] rs10015978 4 79883086 [T/G] rs13150370 4 79887043 [T/C] rs1480713 4 79892811 [T/C] rs4975154 4 79904876 [T/C] NR_038342 LINC01088 Silent rs2046105 4 79907023 [T/C] NR_038342 LINC01088 Silent rs11728698 4 79913463 [A/G] NR_038342 LINC01088 Silent rs17003548 4 79913491 [A/G] NR_038342 LINC01088 Silent rs1545805 4 79914407 [A/G] NR_038342 LINC01088 Silent rs13133376 4 79915288 [A/G] NR_038342 LINC01088 Silent rs4306981 4 79924121 [A/G] NR_038342 LINC01088 Silent rs1585920 4 79927368 [A/G] NR_038342 LINC01088 Silent rs1480720 4 79939309 [A/G] NR_038342 LINC01088 Silent rs286479 4 79947170 [T/C] NR_038342 LINC01088 Silent rs17003582 4 79949599 [A/G] NR_038342 LINC01088 Silent rs7687803 4 79951750 [A/G] NR_038342 LINC01088 Silent rs6852257 4 79957848 [T/C] NR_038342 LINC01088 Silent rs4283690 4 79961845 [T/G] NR_038342 LINC01088 Silent rs286451 4 79967383 [T/C] NR_038342 LINC01088 Silent rs10032909 4 79970208 [A/G] NR_038342 LINC01088 Silent rs2622351 4 79981840 [T/C] NR_038342 LINC01088 Silent rs2622352 4 79982328 [A/C] NR_038342 LINC01088 Silent rs2604828 4 79983945 [T/G] NR_038342 LINC01088 Silent rs2127782 4 79985443 [A/G] NR_038342 LINC01088 Silent rs1455297 4 79991221 [A/G] NR_038342 LINC01088 Silent rs10518213 4 80008023 [T/C] NR_038342 LINC01088 Silent rs1154761 4 80009984 [A/G] NR_038342 LINC01088 Silent rs1378376 4 80010684 [T/G] NR_038342 LINC01088 Silent rs6844930 4 80012823 [A/G] NR_038342 LINC01088 Silent rs4588482 4 80033504 [A/G] NR_038342 LINC01088 Silent rs1378378 4 80034047 [T/C] NR_038342 LINC01088 Silent rs10001729 4 80049788 [A/G] NR_038342 LINC01088 Silent rs10020375 4 80057589 [T/G] NR_038342 LINC01088 Silent rs12648730 4 80059123 [A/G] NR_038342 LINC01088 Silent rs11733517 4 80062229 [A/G] NR_038342 LINC01088 Silent rs17003663 4 80077168 [A/G] NR_038342 LINC01088 Silent rs1078234 4 80084425 [T/C] NR_038342 LINC01088 Silent rs10518214 4 80085942 [T/C] NR_038342 LINC01088 Silent rs1455308 4 80091507 [T/C] NR_038342 LINC01088 Silent rs9884248 4 80099446 [A/G] NR_038342 LINC01088 Silent rs1026394 4 80108181 [T/C] NR_038342 LINC01088 Silent rs7667438 4 80135060 [A/G] NR_038342 LINC01088 Silent rs4975172 4 80146690 [A/G] NR_038342 LINC01088 Silent rs17003682 4 80159839 [T/C] NR_038342 LINC01088 Silent rs4571360 4 80160465 [A/G] NR_038342 LINC01088 Silent rs11098609 4 80179372 [T/C] NR_038342 LINC01088 Silent rs1471729 4 80180855 [A/G] NR_038342 LINC01088 Silent rs17003697 4 80189105 [T/C] NR_038342 LINC01088 Silent rs6534293 4 80202960 [A/G] NR_038342 LINC01088 Silent rs968256 4 80208634 [A/C] NR_038342 LINC01088 Silent rs11930784 4 80217155 [T/C] NR_038342 LINC01088 Silent rs4401473 4 80226156 [A/C] NR_038342 LINC01088 Silent rs1484140 4 80234648 [A/G] rs1385056 4 80238693 [A/G] NM_032693 NAA11 EXON Silent rs13106792 4 80239092 [A/C] NM_032693 NAA11 Silent rs6820325 4 80243645 [A/G] NM_032693 NAA11 Silent rs1545886 4 80255768 [T/C] rs11737437 4 80262521 [T/G] rs10004440 4 80272792 [A/G] rs10017376 4 80309825 [A/C] rs6855734 4 80312214 [A/C] rs17003742 4 80313510 [A/G] rs6534361 4 80316079 [A/G] rs17003749 4 80317772 [A/G] rs17003752 4 80322959 [A/G] rs10003904 4 80326400 [A/G] rs1922285 4 80331240 [A/G] rs10049840 4 80332039 [A/C] rs6837049 4 80334238 [T/C] rs9993682 4 80339467 [A/G] rs9992840 4 80348284 [A/C] rs3924829 4 80352632 [T/C] rs12645140 4 80353066 [T/C] rs6838184 4 80365765 [A/C] rs3920463 4 80375367 [A/G] rs12644205 4 80381867 [T/C] rs7655458 4 80386263 [T/G] rs10518219 4 80387141 [A/C] rs7687998 4 80390999 [T/G] rs10033347 4 80393032 [A/G] rs17443595 4 80394763 [A/G] rs7685006 4 80394862 [T/C] rs10027646 4 80398708 [T/C] rs1115518 4 80412577 [T/G] rs1595965 4 80413707 [A/G] rs7691918 4 80416491 [T/C] NR_038826 LINC00989 Silent rs1561639 4 80420140 [T/G] NR_038826 LINC00989 Silent rs11943366 4 80425028 [A/G] NR_038826 LINC00989 Silent rs998437 4 80429770 [T/C] NR_038826 LINC00989 Silent rs9994690 4 80442759 [T/C] NR_038826 LINC00989 Silent rs2119421 4 80450322 [T/C] NR_038826 LINC00989 Silent rs12507692 4 80461045 [T/C] NR_038826 LINC00989 Silent rs13112577 4 80482400 [T/C] NR_038826 LINC00989 Silent rs10016183 4 80487477 [A/G] NR_038826 LINC00989 Silent rs6850999 4 80501938 [A/G] rs1440853 4 80506647 [A/C] rs12501981 4 80513004 [T/C] rs11935255 4 80518968 [T/C] rs4596267 4 80520206 [A/G] rs11098778 4 80539001 [T/C] rs1808870 4 80543277 [A/C] rs13120966 4 80544474 [T/C] rs1371990 4 80545715 [T/C] rs11098789 4 80550505 [A/G] rs3109166 4 80552199 [T/G] rs3111788 4 80554217 [T/C] rs6819600 4 80558107 [T/C] rs17004018 4 80558341 [A/G] rs3109164 4 80561055 [T/C] rs4490487 4 80561681 [A/G] rs10518222 4 80564868 [A/G] rs7696440 4 80566060 [A/G] rs10518221 4 80570500 [T/C] rs12503047 4 80574242 [T/C] rs7340867 4 80575387 [A/G] rs4975062 4 80579291 [A/G] rs4975105 4 80588739 [T/C] rs4975107 4 80598713 [T/G] rs13123790 4 80598796 [A/G] rs4286542 4 80601457 [T/G] rs17004052 4 80602627 [T/C] rs17447715 4 80602865 [A/G] rs17447799 4 80604625 [A/G] rs17004060 4 80605580 [T/C] rs4975109 4 80606999 [T/C] rs10029533 4 80607964 [T/C] rs4580675 4 80608250 [A/G] rs4547818 4 80609149 [A/G] rs13127915 4 80618658 [A/G] rs4455441 4 80618807 [T/C] rs6534511 4 80620235 [A/C] rs4464597 4 80620555 [T/C] rs11944230 4 80621795 [T/C] rs9999607 4 80632920 [T/C] rs9991949 4 80634958 [T/C] rs4356930 4 80635570 [A/G] rs4362850 4 80636897 [A/C] rs7678939 4 80645990 [T/G] rs7658299 4 80649730 [A/G] rs7657079 4 80652842 [A/G] rs7694021 4 80656305 [A/G] rs9993154 4 80660974 [T/G] rs12510706 4 80661930 [T/C] rs3935850 4 80663590 [A/G] rs10000154 4 80666077 [A/G] rs4270608 4 80667570 [A/G] rs4447889 4 80672520 [A/C] rs17004226 4 80675221 [T/C] rs13134009 4 80675751 [A/C] rs17004230 4 80677687 [A/G] rs17004232 4 80678253 [T/G] rs7665764 4 80681293 [A/G] rs4359935 4 80688131 [T/G] rs4285108 4 80688257 [T/C] rs6534560 4 80688396 [A/G] rs7673654 4 80696259 [A/G] rs17004380 4 80706259 [T/C] rs6813693 4 80719386 [T/C] rs7670590 4 80722214 [A/G] rs4314227 4 80727235 [T/C] rs4381994 4 80732878 [T/G] rs4632591 4 80735714 [T/C] rs10011959 4 80740009 [A/G] rs4690145 4 80742791 [T/C] rs11943513 4 80743976 [A/G] rs11098907 4 80745103 [A/C] rs4546189 4 80749973 [T/C] NR_026555 PCAT4 Silent rs4441708 4 80750928 [T/C] NR_026555 PCAT4 Silent rs13141201 4 80751289 [A/G] NR_026555 PCAT4 Silent rs13103568 4 80752362 [T/C] NR_026555 PCAT4 Silent rs10031299 4 80753792 [T/C] NR_026555 PCAT4 Silent rs7680943 4 80758914 [A/G] NR_026555 PCAT4 Silent rs6855167 4 80769739 [A/G] NR_026555 PCAT4 Silent rs10014970 4 80770939 [A/G] NR_026555 PCAT4 Silent rs6857026 4 80773461 [T/C] NR_026555 PCAT4 Silent rs4271959 4 80778464 [A/G] NR_026555 PCAT4 Silent rs4690123 4 80788782 [A/G] rs6534620 4 80791037 [T/C] rs11735728 4 80793114 [T/C] rs10006442 4 80793143 [A/G] rs11733071 4 80796202 [T/C] rs10011562 4 80799867 [A/G] rs11727192 4 80800327 [T/C] rs10010217 4 80801911 [T/C] rs10020809 4 80805430 [T/C] rs6534625 4 80809997 [A/G] rs6847975 4 80812960 [A/G] rs6534636 4 80816632 [A/G] rs11939401 4 80818417 [T/C] rs4264776 4 80821366 [T/C] rs4371564 4 80825906 [T/G] NM_001286780,NM_058172,NM_001286781 ANTXR2,ANTXR2,ANTXR2 EXON Silent,Silent,Silent rs7747 4 80827062 [T/C] NM_001286780,NM_058172,NM_001286781 ANTXR2,ANTXR2,ANTXR2 EXON Silent,Silent,Silent rs12639837 4 80837239 [A/G] NM_001286780,NM_058172,NM_001286781 ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent rs4234848 4 80850805 [A/G] NM_001286780,NM_058172,NM_001286781 ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent rs6824433 4 80857151 [A/C] NM_001286780,NM_058172,NM_001286781 ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent rs4554013 4 80871932 [A/G] NM_001286780,NM_058172,NM_001286781 ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent rs4511947 4 80872086 [A/G] NM_001286780,NM_058172,NM_001286781 ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent rs10033596 4 80887556 [T/G] NM_001286780,NM_058172,NM_001286781 ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent rs11098964 4 80887969 [A/G] NM_001286780,NM_058172,NM_001286781 ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent rs4444771 4 80906131 [T/C] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs12504282 4 80927001 [T/C] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs4690135 4 80931982 [A/G] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs7682733 4 80933225 [A/G] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs10000471 4 80943688 [T/C] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs4640621 4 80946541 [A/C] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs12645809 4 80948670 [T/C] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs4333130 4 80949829 [T/C] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs7667228 4 80959926 [T/C] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs13132967 4 80968006 [T/C] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs7668399 4 80970213 [A/G] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs13110584 4 80972143 [T/C] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs4308327 4 80978467 [A/G] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs7668376 4 80984670 [T/C] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs11730030 4 80988478 [T/C] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs11099009 4 80988658 [A/G] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs17004812 4 80989462 [A/G] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs17509725 4 80989630 [T/C] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs6839672 4 80993133 [A/G] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 Silent,Silent,Silent,Silent rs13140055 4 80993796 [T/G] NM_001286780,NM_058172,NM_001286781,NM_001145794 ANTXR2,ANTXR2,ANTXR2,ANTXR2 EXON Silent,Silent,Silent,Silent rs12651388 4 80996125 [T/C] rs4234850 4 81001542 [T/C] rs2867698 4 81001940 [T/C] rs7660651 4 81008844 [A/C] rs6847371 4 81018418 [A/G] rs7695893 4 81023146 [A/G] rs7657506 4 81028336 [T/C] rs9307622 4 81055721 [A/C] rs17464115 4 81057927 [T/C] rs2867701 4 81061233 [A/G] rs12513014 4 81061422 [A/G] rs13129263 4 81068101 [A/G] rs13119154 4 81069624 [A/G] rs10518230 4 81071835 [A/G] rs2867696 4 81073276 [T/C] rs13102102 4 81073672 [T/C] rs13102278 4 81073695 [T/C] rs12646498 4 81080290 [T/G] rs13138779 4 81087073 [A/G] rs3755912 4 81103562 [A/G] rs3822010 4 81104548 [A/G] rs3822011 4 81104609 [A/G] rs3755913 4 81105762 [T/C] rs17004832 4 81107049 [T/C] NM_020226 PRDM8 Silent rs6834136 4 81108264 [A/G] NM_020226 PRDM8 Silent rs17530504 4 81109088 [T/C] NM_020226 PRDM8 Silent rs1458043 4 81113195 [T/C] NM_020226 PRDM8 Silent rs2168813 4 81126083 [T/C] rs34319350 4 81130714 [A/C] rs12650744 4 81134893 [T/C] rs6854711 4 81135131 [T/C] rs1458027 4 81140615 [A/G] rs6824301 4 81149169 [A/G] rs17004838 4 81149573 [A/G] rs17004839 4 81149690 [T/G] rs11934116 4 81150109 [T/C] rs11727345 4 81151514 [A/C] rs10518234 4 81152247 [A/G] rs17004844 4 81152804 [A/G] rs7682543 4 81154975 [T/C] rs17004846 4 81158221 [A/G] rs13149993 4 81158545 [A/G] rs7664429 4 81160847 [A/G] rs1458038 4 81164723 [T/C] rs6534834 4 81174237 [A/G] rs10009490 4 81179173 [A/G] rs12054583 4 81181388 [A/G] rs1379706 4 81183900 [T/G] rs17004857 4 81185974 [A/G] rs1047245 4 81187895 [A/C] NM_033143,NM_004464 FGF5,FGF5 EXON Silent,Silent rs716678 4 81190135 [T/C] NM_033143,NM_004464,NM_001291812 FGF5,FGF5,FGF5 Silent,Silent,Silent rs3796605 4 81192363 [A/G] NM_033143,NM_004464,NM_001291812 FGF5,FGF5,FGF5 Silent,Silent,Silent rs6827834 4 81200645 [T/C] NM_033143,NM_004464,NM_001291812 FGF5,FGF5,FGF5 Silent,Silent,Silent rs7683390 4 81202382 [T/C] NM_033143,NM_004464,NM_001291812 FGF5,FGF5,FGF5 Silent,Silent,Silent rs1551589 4 81202398 [T/C] NM_033143,NM_004464,NM_001291812 FGF5,FGF5,FGF5 Silent,Silent,Silent rs17532890 4 81209281 [T/C] NM_033143,NM_004464,NM_001291812 FGF5,FGF5,FGF5 EXON Silent,Silent,Silent rs6849232 4 81209431 [T/G] NM_033143,NM_004464,NM_001291812 FGF5,FGF5,FGF5 EXON Silent,Silent,Silent rs10006753 4 81209842 [A/G] NM_033143,NM_004464,NM_001291812 FGF5,FGF5,FGF5 EXON Silent,Silent,Silent rs11938301 4 81219975 [A/G] rs12650677 4 81223154 [A/G] rs6837827 4 81225455 [T/G] rs747125 4 81227042 [A/G] rs7664124 4 81227964 [A/G] rs7698854 4 81233244 [T/C] rs11934491 4 81240854 [T/C] rs10033567 4 81253388 [A/G] rs1458045 4 81254610 [T/G] rs17004886 4 81283916 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 EXON Synonymous_T40T,Synonymous_T40T rs17004889 4 81307025 [A/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1874337 4 81307865 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs9307678 4 81308107 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs10031438 4 81310385 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1039049 4 81337626 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs6821676 4 81346212 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs17004900 4 81358030 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs7672761 4 81385386 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs11721676 4 81397872 [T/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1874335 4 81401094 [A/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1039053 4 81402774 [A/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs2132264 4 81411451 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs11937407 4 81413618 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs10857170 4 81430314 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs7689698 4 81441082 [A/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs12645025 4 81441407 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs11728439 4 81446625 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs11933716 4 81447179 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs989123 4 81448749 [A/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs13111397 4 81449030 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs17004930 4 81450152 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs12650756 4 81453383 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs11940032 4 81460931 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs11945984 4 81461715 [A/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1531959 4 81462163 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs7666589 4 81488421 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1486016 4 81492374 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1601513 4 81494123 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs13141796 4 81529088 [A/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1385890 4 81535393 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1486025 4 81543568 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs4693532 4 81549972 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs13136169 4 81552878 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs12640833 4 81553197 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs16998198 4 81554785 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs17004962 4 81563339 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs3925214 4 81573178 [T/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs6830979 4 81580392 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs17479000 4 81607195 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs7668590 4 81624639 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs432324 4 81633586 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs11734172 4 81648384 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs11936472 4 81653826 [T/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1493177 4 81667695 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs17004987 4 81671870 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs2903736 4 81703379 [A/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs17004990 4 81708094 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs2047039 4 81735968 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs10031019 4 81759688 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs6849668 4 81764113 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs10028057 4 81773914 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs13131042 4 81773932 [A/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs13107344 4 81776186 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1493182 4 81789570 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1027295 4 81790211 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1027294 4 81790266 [T/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs34620960 4 81794590 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs10026644 4 81801291 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs960168 4 81802673 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs11736970 4 81821346 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs10007113 4 81829660 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs7655600 4 81841042 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs17005004 4 81842668 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1353388 4 81849352 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs10434087 4 81870656 [T/C] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs11099454 4 81883741 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 Silent,Silent rs1052325 4 81884722 [A/G] NM_001206997,NM_152770 CFAP299,CFAP299 EXON Missense_V237I,Missense_V220I rs6851598 4 81890350 [A/G] rs10011602 4 81899545 [A/G] rs7667446 4 81906024 [T/C] rs11099457 4 81913993 [A/G] rs4458448 4 81927206 [T/C] rs6814223 4 81941456 [A/G] rs17005022 4 81943313 [T/C] rs11737492 4 81944280 [A/G] rs17005024 4 81945383 [A/G] rs1353386 4 81947080 [A/C] rs6845445 4 81947402 [A/G] rs7663564 4 81948142 [T/G] rs10022780 4 81948883 [A/G] rs13138361 4 81950655 [A/G] rs10516738 4 81954086 [T/C] NM_001201 BMP3 Silent rs10002189 4 81961697 [A/C] NM_001201 BMP3 Silent rs1495634 4 81963418 [T/C] NM_001201 BMP3 Silent rs10019046 4 81963960 [T/G] NM_001201 BMP3 Silent rs17005033 4 81967439 [A/G] NM_001201 BMP3 EXON Synonymous_K288K rs2903745 4 81968362 [T/C] NM_001201 BMP3 Silent rs1495637 4 81975674 [A/G] NM_001201 BMP3 EXON Silent rs2868076 4 81976873 [A/G] NM_001201 BMP3 EXON Silent rs10007784 4 81977690 [T/C] NM_001201 BMP3 EXON Silent rs4693810 4 81981434 [T/C] rs2685471 4 81981592 [A/G] rs10034749 4 81982259 [T/C] rs10034733 4 81982407 [A/G] rs2643925 4 81984196 [A/G] rs2643921 4 81986784 [A/G] rs2685462 4 81996925 [A/G] rs6849787 4 81999360 [T/C] rs3796804 4 82009707 [T/G] NM_001282480,NM_001282481,NM_001282485,NM_001282483,NM_001363401,NM_006259,NM_001282482 PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17005051 4 82010007 [T/C] NM_001282480,NM_001282481,NM_001282485,NM_001282483,NM_001363401,NM_006259,NM_001282482 PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3822224 4 82010773 [T/C] NM_001282480,NM_001282481,NM_001282485,NM_001282483,NM_001363401,NM_006259,NM_001282482 PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2868132 4 82012206 [A/G] NM_001282480,NM_001282481,NM_001282485,NM_001282483,NM_001363401,NM_006259,NM_001282482 PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11723025 4 82023516 [T/C] NM_001282480,NM_001282481,NM_001282485,NM_001282483,NM_001363401,NM_006259,NM_001282482 PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17005054 4 82025743 [A/G] NM_001282480,NM_001282481,NM_001282485,NM_001282483,NM_001363401,NM_006259,NM_001282482 PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17005056 4 82029505 [A/G] NM_001282480,NM_001282481,NM_001282485,NM_001282483,NM_001363401,NM_006259,NM_001282482 PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6821258 4 82030410 [A/G] NM_001282480,NM_001282481,NM_001282485,NM_001282483,NM_001363401,NM_006259,NM_001282482 PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7675843 4 82035067 [T/C] NM_001282480,NM_001282481,NM_001282485,NM_001282483,NM_001363401,NM_006259,NM_001282482 PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17005061 4 82035993 [T/C] NM_001282480,NM_001282481,NM_001282485,NM_001282483,NM_001363401,NM_006259,NM_001282482 PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11945501 4 82042343 [A/G] NM_001282480,NM_001282481,NM_001282485,NM_001282483,NM_001363401,NM_006259,NM_001282482 PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2868140 4 82058647 [A/G] NM_001282480,NM_001282481,NM_001282485,NM_001282483,NM_001363401,NM_006259,NM_001282482 PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6837293 4 82062931 [T/C] NM_001282480,NM_001282481,NM_001282485,NM_001282483,NM_001363401,NM_006259,NM_001282482 PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7688672 4 82069449 [A/G] NM_001282480,NM_001282481,NM_001282485,NM_001282483,NM_001363401,NM_006259,NM_001282482 PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2,PRKG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11722928 4 82083445 [T/C] NM_001282485,NM_001363401,NM_006259 PRKG2,PRKG2,PRKG2 Silent,Silent,Silent rs10000303 4 82090689 [T/C] NM_001282485,NM_001363401,NM_006259,NR_125908 PRKG2,PRKG2,PRKG2,LOC101928942 Silent,Silent,Silent,Silent rs17005078 4 82092005 [T/C] NM_001282485,NM_001363401,NM_006259,NR_125908 PRKG2,PRKG2,PRKG2,LOC101928942 Silent,Silent,Silent,Silent rs9992933 4 82092967 [T/C] NM_001282485,NM_001363401,NM_006259,NR_125908 PRKG2,PRKG2,PRKG2,LOC101928942 Silent,Silent,Silent,Silent rs1972127 4 82094069 [A/G] NM_001282485,NM_001363401,NM_006259,NR_125908 PRKG2,PRKG2,PRKG2,LOC101928942 Silent,Silent,Silent,Silent rs10005912 4 82097836 [T/G] NM_001282485,NM_001363401,NM_006259,NR_125908 PRKG2,PRKG2,PRKG2,LOC101928942 Silent,Silent,Silent,Silent rs12330930 4 82104348 [A/G] NM_001282485,NM_001363401,NM_006259,NR_125908 PRKG2,PRKG2,PRKG2,LOC101928942 Silent,Silent,Silent,Silent rs3733553 4 82114503 [T/C] NM_001282485,NM_001363401,NM_006259,NR_125908 PRKG2,PRKG2,PRKG2,LOC101928942 EXON Silent,Silent,Silent,Silent rs4149 4 82118352 [T/C] NM_001282485,NM_001363401,NM_006259 PRKG2,PRKG2,PRKG2 Silent,Silent,Silent rs6849299 4 82118996 [A/G] NM_001282485,NM_001363401,NM_006259 PRKG2,PRKG2,PRKG2 Silent,Silent,Silent rs7656323 4 82120029 [T/C] NM_001282485,NM_001363401,NM_006259 PRKG2,PRKG2,PRKG2 Silent,Silent,Silent rs6850526 4 82123118 [A/G] NM_001282485,NM_001363401,NM_006259 PRKG2,PRKG2,PRKG2 Silent,Silent,Silent rs3114135 4 82126316 [T/C] NM_001282485,NM_001363401,NM_006259 PRKG2,PRKG2,PRKG2 Silent,Silent,Silent rs989445 4 82133264 [A/C] NM_001282485,NM_001363401,NM_006259 PRKG2,PRKG2,PRKG2 Silent,Silent,Silent rs710839 4 82134787 [T/C] NM_001282485,NM_001363401,NM_006259 PRKG2,PRKG2,PRKG2 Silent,Silent,Silent rs710840 4 82135230 [A/G] NM_001282485,NM_001363401,NM_006259 PRKG2,PRKG2,PRKG2 Silent,Silent,Silent rs10006461 4 82148261 [T/C] rs17005096 4 82149016 [T/C] rs1712374 4 82154710 [T/C] rs10516652 4 82166904 [T/G] rs1878528 4 82184234 [A/G] rs7687899 4 82184539 [T/G] rs1901568 4 82187030 [T/C] rs6535239 4 82192994 [A/G] rs2034629 4 82226349 [A/G] rs10028430 4 82235733 [T/C] rs7681976 4 82241612 [T/C] rs17005110 4 82266866 [A/G] rs4277772 4 82274298 [A/G] rs10488933 4 82276379 [A/G] rs1452373 4 82284055 [T/C] rs13435795 4 82287652 [A/G] rs11723619 4 82287755 [T/G] rs6535244 4 82290018 [T/G] rs17005123 4 82315470 [A/C] rs10028610 4 82318524 [A/G] rs17500100 4 82324437 [A/G] rs17005129 4 82324877 [A/C] rs17500149 4 82325636 [T/C] rs10488931 4 82329840 [T/C] rs10488930 4 82330924 [A/G] rs10488929 4 82332475 [T/C] rs10488928 4 82332999 [A/C] rs4692955 4 82338731 [T/C] rs6836031 4 82339079 [A/C] rs6823416 4 82339516 [T/C] rs17005131 4 82340277 [T/C] rs17005133 4 82340952 [A/G] rs1037405 4 82347502 [A/G] rs2159657 4 82355593 [A/G] NM_152545,NM_001300735,NM_001300736 RASGEF1B,RASGEF1B,RASGEF1B Silent,Silent,Silent rs10010385 4 82364962 [T/C] NM_152545,NM_001300735,NM_001300736 RASGEF1B,RASGEF1B,RASGEF1B Silent,Silent,Silent rs6839120 4 82365496 [A/G] NM_152545,NM_001300735,NM_001300736 RASGEF1B,RASGEF1B,RASGEF1B Silent,Silent,Silent rs10019810 4 82374060 [A/G] NM_152545,NM_001300735,NM_001300736 RASGEF1B,RASGEF1B,RASGEF1B Silent,Silent,Silent rs17558056 4 82375936 [T/C] NM_152545,NM_001300735,NM_001300736 RASGEF1B,RASGEF1B,RASGEF1B Silent,Silent,Silent rs1444891 4 82376621 [T/C] NM_152545,NM_001300735,NM_001300736 RASGEF1B,RASGEF1B,RASGEF1B Silent,Silent,Silent rs2868215 4 82377329 [A/G] NM_152545,NM_001300735,NM_001300736 RASGEF1B,RASGEF1B,RASGEF1B Silent,Silent,Silent rs895086 4 82381313 [A/G] NM_152545,NM_001300735,NM_001300736 RASGEF1B,RASGEF1B,RASGEF1B Silent,Silent,Silent rs748436 4 82381627 [T/C] NM_152545,NM_001300735,NM_001300736 RASGEF1B,RASGEF1B,RASGEF1B Silent,Silent,Silent rs7670580 4 82382526 [T/G] NM_152545,NM_001300735,NM_001300736 RASGEF1B,RASGEF1B,RASGEF1B Silent,Silent,Silent rs13353696 4 82393862 [A/G] rs10015146 4 82401332 [T/C] rs17005142 4 82402588 [T/C] rs6819741 4 82403942 [A/G] rs17005144 4 82404274 [T/C] rs11939325 4 82417143 [T/C] rs2166181 4 82422327 [A/G] rs10018581 4 82422433 [T/C] rs11930241 4 82426814 [A/G] rs6840449 4 82427419 [A/G] rs13147840 4 82429283 [A/G] rs882043 4 82430252 [A/C] rs17005153 4 82432524 [A/G] rs1011631 4 82440730 [T/C] rs7672307 4 82441160 [T/G] rs35142427 4 82441375 [T/G] rs6841069 4 82448309 [A/G] rs1348601 4 82452878 [T/G] rs10019003 4 82452933 [T/C] rs17005157 4 82459940 [T/C] rs17005158 4 82460221 [A/G] rs1373637 4 82473932 [T/C] rs2018726 4 82476030 [T/C] rs9307785 4 82482584 [A/G] rs10022264 4 82484170 [T/C] rs17005165 4 82486754 [T/C] rs10033009 4 82492363 [T/C] rs10033652 4 82493067 [T/C] rs4693298 4 82506162 [A/G] rs6812919 4 82518513 [T/C] rs6535261 4 82519643 [A/G] rs10024593 4 82534135 [A/G] rs11099482 4 82541771 [A/G] rs11933681 4 82547364 [A/G] rs7662480 4 82549474 [T/C] rs7657174 4 82556945 [T/G] rs4396981 4 82564162 [T/C] rs10434096 4 82569389 [A/G] rs4073341 4 82572441 [A/G] rs6853493 4 82584423 [T/C] rs11099493 4 82587050 [A/G] rs4437242 4 82595257 [T/G] rs4074490 4 82597792 [A/C] rs9307786 4 82600430 [T/C] rs9985504 4 82602057 [T/C] rs6535273 4 82616045 [T/C] rs9992825 4 82619170 [A/G] rs4401444 4 82620131 [A/C] rs7683827 4 82628567 [T/G] rs6834681 4 82634810 [A/G] rs7697168 4 82643252 [A/C] rs6822657 4 82654242 [A/G] rs1353663 4 82659400 [A/G] rs1497784 4 82659919 [T/C] rs13130258 4 82663581 [T/C] rs7676794 4 82664674 [A/G] rs7680648 4 82666782 [A/G] rs6819863 4 82667620 [T/C] rs10029907 4 82675764 [T/G] rs6535279 4 82677938 [T/G] rs10516659 4 82680686 [T/C] rs7696872 4 82687275 [A/G] rs4693005 4 82687523 [A/G] rs17568540 4 82688257 [T/C] rs9307787 4 82690494 [A/C] rs2055263 4 82698629 [A/C] rs523329 4 82720331 [T/C] rs751104 4 82723964 [T/G] rs515108 4 82730697 [T/C] rs1497770 4 82734906 [T/C] rs6535280 4 82738099 [A/G] rs17570404 4 82744243 [T/C] rs4566646 4 82744299 [A/G] rs685815 4 82752721 [T/G] rs583138 4 82766046 [A/G] rs7653998 4 82767175 [A/G] rs4693387 4 82767300 [A/G] rs666149 4 82773619 [T/C] rs667443 4 82779892 [T/C] rs1824657 4 82783136 [T/C] rs10002393 4 82786911 [T/C] rs17571905 4 82805077 [T/C] rs7663795 4 82812093 [A/G] rs1462694 4 82816806 [T/C] rs2199487 4 82820008 [A/G] rs12500182 4 82820406 [A/G] rs7673236 4 82825171 [T/C] rs1982618 4 82835295 [T/G] rs11947229 4 82839536 [A/G] rs4693011 4 82843061 [T/C] rs10516668 4 82843970 [A/G] rs2120368 4 82865191 [T/C] rs320754 4 82875045 [A/C] rs1599650 4 82878952 [A/C] rs320770 4 82889237 [A/G] rs11099512 4 82895808 [T/C] rs6838368 4 82896567 [T/C] rs11099514 4 82896862 [A/G] rs11730183 4 82900372 [T/C] rs17515274 4 82905378 [A/G] rs1443785 4 82910126 [T/C] rs12650942 4 82913135 [A/G] rs12711232 4 82914118 [A/G] rs13109155 4 82915079 [A/G] rs4693013 4 82915702 [T/C] rs7670373 4 82917515 [T/C] rs2868278 4 82922668 [T/C] rs7678127 4 82928877 [A/G] rs11939555 4 82928896 [A/G] rs6814999 4 82932359 [T/C] rs1443769 4 82949189 [T/C] rs1443771 4 82953110 [A/G] rs1470338 4 82955013 [A/G] rs4693416 4 82956948 [T/C] rs1443772 4 82959120 [T/C] rs1562030 4 82962095 [A/G] rs7671690 4 82964509 [A/C] rs7654293 4 82974329 [A/G] rs971825 4 82975345 [A/G] rs7664786 4 82977205 [T/C] rs12508988 4 82978391 [T/C] rs2131361 4 82980833 [T/G] rs4693418 4 82981181 [T/C] rs1373238 4 82981940 [T/G] rs10010220 4 82990379 [A/G] rs1038882 4 82991922 [A/G] rs1492847 4 82992937 [T/C] rs7673475 4 82996183 [T/C] rs2035912 4 83007475 [T/C] rs4693421 4 83019396 [T/C] rs6845139 4 83026356 [A/G] rs6535307 4 83026416 [A/G] rs2011786 4 83028150 [A/G] rs10009173 4 83029942 [T/C] rs7677948 4 83044475 [A/G] rs17005442 4 83044713 [A/C] rs11943170 4 83045736 [A/G] rs7657850 4 83050748 [A/G] rs1826470 4 83051821 [T/C] rs962753 4 83058150 [T/C] rs13109978 4 83059714 [A/G] rs6812383 4 83062902 [A/G] rs17005475 4 83067671 [A/G] rs1492848 4 83068042 [T/G] rs6852216 4 83073594 [T/C] rs6825436 4 83085123 [T/C] rs2868298 4 83087694 [T/C] rs13116695 4 83094251 [A/G] rs2101680 4 83096524 [T/C] rs10019349 4 83102836 [T/C] rs12507749 4 83112989 [T/C] rs1389044 4 83114530 [T/C] rs2035910 4 83115166 [A/C] rs12510027 4 83115740 [T/C] rs4146415 4 83115904 [T/G] rs4693432 4 83116329 [T/G] rs11941179 4 83130688 [A/G] rs4693023 4 83132921 [T/C] rs4693026 4 83149478 [A/G] rs2583636 4 83153179 [T/G] rs1964333 4 83155636 [T/C] rs2556543 4 83160983 [A/C] rs7660665 4 83164184 [A/G] rs2114693 4 83170172 [T/C] rs7678274 4 83171331 [T/C] rs2303571 4 83177773 [T/C] rs17005556 4 83188821 [T/C] rs6815242 4 83189631 [A/G] rs13119500 4 83196536 [A/G] rs7692570 4 83209493 [T/C] rs17005574 4 83210000 [A/G] rs6822283 4 83218230 [T/C] rs1116664 4 83237661 [T/G] rs1961547 4 83266333 [T/C] rs34471118 4 83273140 [A/G] rs2288338 4 83274634 [T/C] NM_031369,NM_031370,NM_002138,NM_001003810 HNRNPD,HNRNPD,HNRNPD,HNRNPD EXON Silent,Silent,Silent,Silent rs1820577 4 83278778 [T/C] NM_031369,NM_031370,NM_002138,NM_001003810 HNRNPD,HNRNPD,HNRNPD,HNRNPD Silent,Silent,Silent,Silent rs11722069 4 83289373 [T/C] NM_031369,NM_031370,NM_002138,NM_001003810 HNRNPD,HNRNPD,HNRNPD,HNRNPD Silent,Silent,Silent,Silent rs12711238 4 83300578 [T/G] rs3762885 4 83305278 [T/G] rs6843699 4 83309685 [A/G] rs6816230 4 83312849 [A/G] rs13105860 4 83317753 [A/G] rs2004987 4 83319611 [T/C] rs17005633 4 83321808 [T/C] rs7695741 4 83323062 [T/C] rs13125359 4 83325574 [A/G] rs7662802 4 83334895 [A/G] rs1559949 4 83340605 [A/G] rs11737188 4 83343745 [T/C] NM_001207000,NR_003249,NM_031372 HNRNPDL,HNRNPDL,HNRNPDL EXON Silent,Silent,Silent rs997720 4 83345146 [A/G] NM_001207000,NR_003249,NM_031372 HNRNPDL,HNRNPDL,HNRNPDL EXON Silent,Silent,Silent rs997721 4 83345292 [T/C] NM_001207000,NR_003249,NM_031372 HNRNPDL,HNRNPDL,HNRNPDL EXON Silent,Silent,Silent rs6826022 4 83348978 [T/C] NM_001207000,NR_003249,NM_031372 HNRNPDL,HNRNPDL,HNRNPDL Silent,Silent,Silent rs8732 4 83351821 [A/G] NM_001292017,NR_120457,NM_021204 ENOPH1,ENOPH1,ENOPH1 EXON Silent,Silent,Silent rs10516674 4 83358762 [T/C] NM_001292017,NR_120457,NM_021204 ENOPH1,ENOPH1,ENOPH1 Silent,Silent,Silent rs1878494 4 83362192 [A/G] NM_001292017,NR_120457,NM_021204 ENOPH1,ENOPH1,ENOPH1 Silent,Silent,Silent rs1113576 4 83368980 [T/C] NM_001292017,NR_120457,NM_021204 ENOPH1,ENOPH1,ENOPH1 Silent,Silent,Silent rs4285076 4 83369287 [A/G] NM_001292017,NR_120457,NM_021204 ENOPH1,ENOPH1,ENOPH1 Silent,Silent,Silent rs6822360 4 83373747 [A/G] NM_001292017,NR_120457,NM_021204 ENOPH1,ENOPH1,ENOPH1 Silent,Silent,Silent rs1980187 4 83378872 [T/G] NM_001292017,NR_120457,NM_021204 ENOPH1,ENOPH1,ENOPH1 Silent,Silent,Silent rs11929894 4 83379826 [T/C] NM_001292017,NR_120457,NM_021204 ENOPH1,ENOPH1,ENOPH1 Silent,Silent,Silent rs3796470 4 83381564 [A/C] NM_001292017,NR_120457,NM_021204 ENOPH1,ENOPH1,ENOPH1 EXON Silent,Silent,Silent rs13114300 4 83403563 [T/G] rs6818677 4 83405383 [T/C] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C EXON Silent,Silent,Silent rs1543163 4 83411635 [A/C] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs4693448 4 83418930 [A/G] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs10003787 4 83421440 [T/G] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs873931 4 83421896 [T/C] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs4693450 4 83427464 [T/C] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs10016201 4 83431048 [T/G] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs6828071 4 83431790 [T/C] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs953186 4 83433406 [T/C] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs12506540 4 83436006 [T/G] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs6535350 4 83439160 [A/G] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs7671872 4 83441867 [T/G] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs17005758 4 83442908 [A/G] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs6836241 4 83443054 [T/G] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs17005759 4 83446505 [T/C] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs10014422 4 83447641 [T/C] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs4693453 4 83448507 [A/G] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs4693454 4 83448764 [A/G] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs1316596 4 83451071 [A/G] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs11946794 4 83458667 [A/C] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs10516675 4 83462935 [T/C] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs2056185 4 83465498 [A/G] NM_001353455,NM_001353454,NM_001080506 TMEM150C,TMEM150C,TMEM150C Silent,Silent,Silent rs4693458 4 83485723 [T/G] rs2176401 4 83486981 [T/C] rs11728793 4 83491535 [T/C] rs4693460 4 83503020 [A/C] rs11723799 4 83507794 [T/G] rs4693465 4 83521262 [A/G] rs17005836 4 83527733 [A/C] rs6845080 4 83534854 [T/C] NR_024088,NR_024087 LINC00575,LINC00575 Silent,Silent rs10004759 4 83535197 [T/G] NR_024088,NR_024087 LINC00575,LINC00575 EXON Silent,Silent rs11729944 4 83535880 [A/C] NR_024088,NR_024087 LINC00575,LINC00575 Silent,Silent rs11734355 4 83536279 [A/G] NR_024088,NR_024087 LINC00575,LINC00575 Silent,Silent rs6853729 4 83538430 [T/C] NR_024088,NR_024087 LINC00575,LINC00575 Silent,Silent rs6842536 4 83539606 [T/C] NR_024088,NR_024087 LINC00575,LINC00575 Silent,Silent rs4693468 4 83547584 [T/C] rs6840 4 83551007 [A/G] NM_001037582 SCD5 EXON Silent rs1065403 4 83551119 [T/C] NM_001037582 SCD5 EXON Silent rs7672297 4 83554880 [T/G] NM_001037582 SCD5 Silent rs1395370 4 83559578 [A/C] NM_001037582 SCD5 Silent rs9991687 4 83560949 [A/G] NM_001037582 SCD5 Silent rs6535360 4 83561503 [T/C] NM_001037582 SCD5 Silent rs1506606 4 83564114 [A/G] NM_001037582 SCD5 Silent rs996465 4 83564947 [A/C] NM_001037582 SCD5 Silent rs1506604 4 83567535 [T/G] NM_001037582 SCD5 Silent rs1317366 4 83569708 [A/G] NM_001037582 SCD5 Silent rs11935974 4 83573730 [A/G] NM_001037582 SCD5 Silent rs12500897 4 83576973 [A/C] NM_001037582 SCD5 Silent rs3733228 4 83582064 [T/G] NM_001037582,NM_024906 SCD5,SCD5 EXON Silent,Missense_L246M rs6830953 4 83585662 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs2135507 4 83586671 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs6811012 4 83590099 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs10030631 4 83596745 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs7689308 4 83597815 [A/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs7695607 4 83598784 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs2276883 4 83602150 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs11938637 4 83602396 [A/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs6834939 4 83609415 [A/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs7684141 4 83610429 [A/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs17353688 4 83613357 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs953534 4 83617849 [A/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs6852540 4 83623978 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs1354749 4 83625201 [T/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs1876218 4 83626382 [A/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs4693491 4 83627583 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs7698751 4 83629897 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs7674113 4 83635676 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs4693496 4 83637368 [A/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs4693497 4 83638620 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs10025210 4 83639461 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs10516678 4 83644676 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs1358055 4 83648552 [A/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs10009661 4 83649829 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs4693501 4 83650157 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs7698558 4 83652046 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs17006191 4 83652094 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs17351781 4 83653670 [A/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs6822001 4 83653968 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs4693052 4 83654463 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs13124051 4 83656703 [A/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs951500 4 83659028 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs11733801 4 83659628 [T/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs4626189 4 83659974 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs17354029 4 83660842 [A/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs12650548 4 83661968 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs10019834 4 83662588 [A/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs17006239 4 83663494 [A/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs7683924 4 83664375 [T/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs13148235 4 83668072 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs11933135 4 83668410 [A/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs17006278 4 83672163 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs13139428 4 83673572 [T/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs11732247 4 83680552 [A/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs11729909 4 83682200 [A/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs11726264 4 83687425 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs1980360 4 83694283 [A/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs11099549 4 83697854 [T/C] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs11099551 4 83700755 [A/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs3857139 4 83710092 [A/G] NM_001037582,NM_024906 SCD5,SCD5 Silent,Silent rs6841081 4 83719944 [A/C] NM_001037582,NM_024906 SCD5,SCD5 EXON Silent,Silent rs17354301 4 83725273 [T/G] rs4235052 4 83733766 [A/G] rs12331100 4 83740718 [T/C] NM_016211,NM_001318120,NM_001077206,NM_001191049,NM_001300745,NM_001300744,NM_001077207,NM_001318119,NM_001077208 SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1136882 4 83758827 [T/C] NM_016211,NM_001318120,NM_001077206,NM_001191049,NM_001300745,NM_001300744,NM_001077207,NM_001318119,NM_001077208 SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7658703 4 83778839 [T/C] NM_016211,NM_001318120,NM_001077206,NM_001191049,NM_001300745,NM_001300744,NM_001077207,NM_001318119,NM_001077208 SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3797036 4 83785581 [A/C] NM_016211,NM_001318120,NM_001077206,NM_001191049,NM_001300745,NM_001300744,NM_001077207,NM_001318119,NM_001077208 SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A EXON Missense_N456K,Missense_N456K,Missense_N456K,Missense_N451K,Missense_N456K,Missense_N456K,Missense_N456K,Missense_N456K,Missense_N456K rs3762901 4 83791959 [T/G] NM_016211,NM_001318120,NM_001077206,NM_001191049,NM_001300745,NM_001300744,NM_001077207,NM_001318119,NM_001077208 SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10025654 4 83795806 [T/C] NM_016211,NM_001318120,NM_001077206,NM_001191049,NM_001300745,NM_001300744,NM_001077207,NM_001318119,NM_001077208 SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A EXON Synonymous_R199R,Synonymous_R199R,Synonymous_R199R,Synonymous_R194R,Synonymous_R199R,Synonymous_R199R,Synonymous_R199R,Synonymous_R199R,Synonymous_R199R rs6830527 4 83798446 [T/G] NM_016211,NM_001318120,NM_001077206,NM_001191049,NM_001300745,NM_001300744,NM_001077207,NM_001318119,NM_001077208 SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7656058 4 83800428 [A/G] NM_016211,NM_001318120,NM_001077206,NM_001191049,NM_001300745,NM_001300744,NM_001077207,NM_001318119,NM_001077208 SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7682147 4 83807801 [A/G] NM_016211,NM_001318120,NM_001077206,NM_001191049,NM_001300745,NM_001300744,NM_001077207,NM_001318119,NM_001077208 SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17006357 4 83811756 [A/C] NM_016211,NM_001318120,NM_001077206,NM_001191049,NM_001300745,NM_001300744,NM_001077207,NM_001318119,NM_001077208 SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A,SEC31A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1020748 4 83814018 [A/G] NM_001318120 SEC31A Silent rs1031640 4 83817693 [T/C] NM_001318120,NR_034077,NR_034075,NR_034076 SEC31A,THAP9-AS1,THAP9-AS1,THAP9-AS1 Silent,Silent,Silent,Silent rs1350386 4 83819464 [T/C] NM_001318120,NR_034077,NR_034075,NR_034076 SEC31A,THAP9-AS1,THAP9-AS1,THAP9-AS1 Silent,Silent,Silent,Silent rs4302451 4 83820170 [A/G] NM_001318120,NR_034077,NR_034075,NR_034076 SEC31A,THAP9-AS1,THAP9-AS1,THAP9-AS1 Silent,Silent,Silent,Silent rs10857215 4 83833473 [T/C] NM_024672,NM_001317776 THAP9,THAP9 Silent,Silent rs17006379 4 83834682 [T/G] NM_024672,NM_001317776 THAP9,THAP9 Silent,Silent rs897945 4 83838262 [T/G] NM_024672,NM_001317776 THAP9,THAP9 EXON Missense_L299F,Missense_L155F rs1047564 4 83840906 [A/G] NM_024672,NM_001317776 THAP9,THAP9 EXON Silent,Silent rs13132580 4 83848388 [T/C] NM_194282,NM_001288996,NM_001115008,NM_001115007,NR_110253,NM_001288997,NR_110254 LIN54,LIN54,LIN54,LIN54,LIN54,LIN54,LIN54 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1473394 4 83862479 [T/G] NM_194282,NM_001288996,NM_001115008,NM_001115007,NR_110253,NM_001288997,NR_110254 LIN54,LIN54,LIN54,LIN54,LIN54,LIN54,LIN54 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11938691 4 83873373 [A/G] NM_194282,NM_001288996,NM_001115008,NM_001115007,NR_110253,NM_001288997,NR_110254 LIN54,LIN54,LIN54,LIN54,LIN54,LIN54,LIN54 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10000180 4 83899764 [A/G] NM_194282,NM_001288996,NM_001115008,NM_001115007,NR_110253,NM_001288997,NR_110254 LIN54,LIN54,LIN54,LIN54,LIN54,LIN54,LIN54 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6535422 4 83900043 [A/G] NM_194282,NM_001288996,NM_001115008,NM_001115007,NR_110253,NM_001288997,NR_110254 LIN54,LIN54,LIN54,LIN54,LIN54,LIN54,LIN54 EXON Synonymous_V267V,Silent,Synonymous_V46V,Synonymous_V46V,Silent,Synonymous_V46V,Silent rs1020750 4 83903849 [A/G] NM_194282,NM_001288996,NM_001115008,NM_001115007,NR_110253,NM_001288997,NR_110254 LIN54,LIN54,LIN54,LIN54,LIN54,LIN54,LIN54 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11099563 4 83907105 [A/G] NM_194282,NM_001288996,NM_001115008,NM_001115007,NR_110253,NM_001288997,NR_110254 LIN54,LIN54,LIN54,LIN54,LIN54,LIN54,LIN54 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6847544 4 83911526 [T/G] NM_194282,NM_001288996,NM_001115008,NM_001115007,NR_110253,NM_001288997,NR_110254 LIN54,LIN54,LIN54,LIN54,LIN54,LIN54,LIN54 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9307811 4 83923869 [T/C] NM_194282,NM_001288996,NM_001115008,NM_001115007,NR_110253,NM_001288997,NR_110254 LIN54,LIN54,LIN54,LIN54,LIN54,LIN54,LIN54 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7691430 4 83929394 [T/G] NM_194282,NM_001288996,NM_001115008,NM_001115007,NR_110253,NM_001288997,NR_110254 LIN54,LIN54,LIN54,LIN54,LIN54,LIN54,LIN54 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10024720 4 83930859 [T/C] NM_194282,NM_001288996,NM_001115008,NM_001115007,NR_110253,NM_001288997,NR_110254 LIN54,LIN54,LIN54,LIN54,LIN54,LIN54,LIN54 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10033399 4 83939171 [T/C] rs897943 4 83942485 [T/C] rs6853728 4 83948407 [A/G] rs10857217 4 83949952 [T/G] rs6821110 4 83954383 [A/C] rs7682744 4 83955450 [T/C] rs13149890 4 83956440 [A/T] NM_016129,NM_001258006,NM_001330727 COPS4,COPS4,COPS4 EXON Missense_D21E,Missense_D21E,Missense_D21E rs11945022 4 83992281 [T/C] NM_016129,NM_001258006,NM_001330727 COPS4,COPS4,COPS4 Silent,Silent,Silent rs11947785 4 83997158 [A/G] rs11732191 4 84005377 [A/G] rs11722733 4 84011131 [T/C] rs11099568 4 84013292 [A/G] NM_001130716,NM_016619 PLAC8,PLAC8 Silent,Silent rs11099569 4 84013509 [T/G] NM_001130716,NM_016619 PLAC8,PLAC8 Silent,Silent rs7692926 4 84017945 [T/C] NM_001130716,NM_016619,NM_001130715 PLAC8,PLAC8,PLAC8 Silent,Silent,Silent rs6846520 4 84018272 [A/G] NM_001130716,NM_016619,NM_001130715 PLAC8,PLAC8,PLAC8 Silent,Silent,Silent rs7688441 4 84026991 [T/C] NM_001130716,NM_016619,NM_001130715 PLAC8,PLAC8,PLAC8 Silent,Silent,Silent rs2868763 4 84034675 [T/C] NM_016619,NM_001130715 PLAC8,PLAC8 Silent,Silent rs2868750 4 84045915 [T/C] rs12510343 4 84053945 [T/G] rs2868752 4 84058227 [A/C] rs11940883 4 84059844 [A/G] rs6852740 4 84065038 [T/C] rs7657984 4 84072132 [A/G] rs9999963 4 84072737 [T/C] rs10516683 4 84074826 [A/G] rs7673451 4 84091444 [T/C] rs17006541 4 84096948 [T/C] rs9307817 4 84100431 [A/C] rs2868760 4 84100592 [A/C] rs7679817 4 84120705 [A/G] rs2903913 4 84123698 [T/C] rs12508182 4 84130153 [T/C] rs10033388 4 84131775 [A/G] rs11731396 4 84133315 [A/C] rs6854272 4 84140400 [T/C] rs6856697 4 84143589 [T/C] rs11942687 4 84145617 [T/C] rs17352615 4 84151064 [T/C] rs13122305 4 84152973 [A/G] rs6840620 4 84153610 [T/C] rs6819374 4 84156465 [A/G] rs4396979 4 84168653 [T/C] rs4346637 4 84175235 [A/C] rs10002954 4 84177179 [A/G] rs6535450 4 84179480 [A/G] rs10021552 4 84182602 [T/G] rs4693596 4 84189869 [T/C] NM_015697,NM_001358921 COQ2,COQ2 Silent,Silent rs11099588 4 84201479 [T/C] NM_015697,NM_001358921 COQ2,COQ2 Silent,Silent rs6849677 4 84202683 [T/C] NM_015697,NM_001358921 COQ2,COQ2 Silent,Silent rs10025120 4 84216941 [A/C] NM_006665,NM_001166498,NM_001098540,NM_001199830 HPSE,HPSE,HPSE,HPSE Silent,Silent,Silent,Silent rs9307824 4 84220612 [T/C] NM_006665,NM_001166498,NM_001098540,NM_001199830 HPSE,HPSE,HPSE,HPSE Silent,Silent,Silent,Silent rs11726245 4 84226063 [A/G] NM_006665,NM_001166498,NM_001098540,NM_001199830 HPSE,HPSE,HPSE,HPSE Silent,Silent,Silent,Silent rs11099592 4 84230619 [T/C] NM_006665,NM_001166498,NM_001098540,NM_001199830 HPSE,HPSE,HPSE,HPSE EXON Missense_K307R,Missense_K307R,Missense_K307R,Missense_K249R rs6535458 4 84233449 [T/C] NM_006665,NM_001166498,NM_001098540,NM_001199830 HPSE,HPSE,HPSE,HPSE Silent,Silent,Silent,Silent rs4693608 4 84241357 [A/G] NM_006665,NM_001166498,NM_001098540,NM_001199830 HPSE,HPSE,HPSE,HPSE Silent,Silent,Silent,Silent rs4328905 4 84243549 [A/G] NM_006665,NM_001166498,NM_001098540,NM_001199830 HPSE,HPSE,HPSE,HPSE Silent,Silent,Silent,Silent rs7670729 4 84246090 [A/G] NM_006665,NM_001166498,NM_001098540,NM_001199830 HPSE,HPSE,HPSE,HPSE Silent,Silent,Silent,Silent rs11722753 4 84247056 [T/C] NM_006665,NM_001166498,NM_001098540,NM_001199830 HPSE,HPSE,HPSE,HPSE Silent,Silent,Silent,Silent rs4693612 4 84253150 [T/C] NM_006665,NM_001166498,NM_001098540,NM_001199830 HPSE,HPSE,HPSE,HPSE Silent,Silent,Silent,Silent rs12507864 4 84254494 [T/C] NM_006665,NM_001166498,NM_001098540,NM_001199830 HPSE,HPSE,HPSE,HPSE Silent,Silent,Silent,Silent rs4693614 4 84260521 [A/G] rs6850253 4 84266843 [A/G] rs11932833 4 84272944 [T/G] rs6831788 4 84282828 [T/C] rs7436836 4 84288014 [A/G] rs6854611 4 84288613 [T/C] rs6535469 4 84289142 [T/G] rs4311309 4 84290641 [A/G] rs7683970 4 84294277 [A/C] rs12650866 4 84295261 [A/C] rs13128996 4 84298192 [A/G] rs6831180 4 84304734 [T/C] rs10516684 4 84310711 [A/G] rs10004897 4 84312759 [A/G] rs7681313 4 84317759 [A/C] rs17006780 4 84325901 [A/G] rs17006794 4 84328632 [T/C] NM_001297757,NM_133636,NM_001297756,NM_001297755 HELQ,HELQ,HELQ,HELQ EXON Missense_V550M,Missense_V1094M,Missense_V597M,Missense_V1027M rs17006802 4 84330059 [A/G] NM_001297757,NM_133636,NM_001297756,NM_001297755 HELQ,HELQ,HELQ,HELQ Silent,Silent,Silent,Silent rs4693623 4 84331768 [T/C] NM_001297757,NM_133636,NM_001297756,NM_001297755 HELQ,HELQ,HELQ,HELQ Silent,Silent,Silent,Silent rs1565908 4 84347423 [T/C] NM_001297757,NM_133636,NM_001297756,NM_001297755 HELQ,HELQ,HELQ,HELQ Silent,Silent,Silent,Silent rs7658363 4 84356454 [A/G] NM_001297757,NM_133636,NM_001297756,NM_001297755 HELQ,HELQ,HELQ,HELQ Silent,Silent,Silent,Silent rs7665103 4 84364751 [A/G] NM_001297757,NM_133636,NM_001297756,NM_001297755 HELQ,HELQ,HELQ,HELQ EXON Silent,Synonymous_I494I,Silent,Synonymous_I427I rs17006825 4 84368630 [A/G] NM_001297757,NM_133636,NM_001297756,NM_001297755 HELQ,HELQ,HELQ,HELQ Silent,Silent,Silent,Silent rs13141136 4 84370091 [A/G] NM_001297757,NM_133636,NM_001297756,NM_001297755 HELQ,HELQ,HELQ,HELQ EXON Silent,Synonymous_L346L,Silent,Synonymous_L346L rs4693626 4 84372998 [T/C] NM_001297757,NM_133636,NM_001297756,NM_001297755 HELQ,HELQ,HELQ,HELQ Silent,Silent,Silent,Silent rs1494961 4 84374480 [T/C] NM_001297757,NM_133636,NM_001297756,NM_001297755,NR_123737,NM_001297758,NM_001297759 HELQ,HELQ,HELQ,HELQ,HELQ,HELQ,HELQ EXON Silent,Missense_V306I,Silent,Missense_V306I,Silent,Missense_V269I,Missense_V306I rs17006837 4 84374692 [A/G] NM_001297757,NM_133636,NM_001297756,NM_001297755,NR_123737,NM_001297758,NM_001297759 HELQ,HELQ,HELQ,HELQ,HELQ,HELQ,HELQ EXON Silent,Missense_L235P,Silent,Missense_L235P,Silent,Missense_L198P,Missense_L235P rs10516687 4 84376443 [T/C] NM_001297757,NM_133636,NM_001297756,NM_001297755,NR_123737,NM_001297758,NM_001297759 HELQ,HELQ,HELQ,HELQ,HELQ,HELQ,HELQ EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10516688 4 84376981 [A/C] NM_001297757,NM_133636,NM_001297756,NM_001297755,NR_123737,NM_001297758,NM_001297759 HELQ,HELQ,HELQ,HELQ,HELQ,HELQ,HELQ EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12505955 4 84380955 [T/G] NM_016067,NM_001297770,NM_001297769,NM_001297767 MRPS18C,MRPS18C,MRPS18C,MRPS18C Silent,Silent,Silent,Silent rs11099601 4 84382763 [T/C] NM_016067,NM_001297770,NM_001297769,NM_001297767,NM_001345962,NM_139076 MRPS18C,MRPS18C,MRPS18C,MRPS18C,ABRAXAS1,ABRAXAS1 EXON Silent,Silent,Silent,Silent,Silent,Silent rs13125836 4 84383735 [T/C] NM_001345962,NM_139076 ABRAXAS1,ABRAXAS1 EXON Missense_D264N,Missense_D373N rs12642536 4 84383810 [T/C] NM_001345962,NM_139076 ABRAXAS1,ABRAXAS1 EXON Missense_A239T,Missense_A348T rs10516689 4 84384995 [T/C] NM_001345962,NM_139076 ABRAXAS1,ABRAXAS1 Silent,Silent rs12499395 4 84387157 [T/C] NM_001345962,NM_139076 ABRAXAS1,ABRAXAS1 Silent,Silent rs17355027 4 84388915 [T/C] NM_001345962,NM_139076 ABRAXAS1,ABRAXAS1 Silent,Silent rs17006851 4 84400120 [A/G] NM_001345962,NM_139076 ABRAXAS1,ABRAXAS1 Silent,Silent rs546431 4 84408013 [A/G] rs28488925 4 84414282 [T/C] rs529283 4 84420901 [T/C] rs17352915 4 84434011 [T/C] rs9999564 4 84444097 [T/C] rs568834 4 84451096 [A/G] rs6535480 4 84455200 [T/C] rs9992543 4 84456409 [T/C] rs4996767 4 84456808 [T/G] rs10516690 4 84465613 [T/C] NM_001256422,NM_001256421,NM_032717 GPAT3,GPAT3,GPAT3 Silent,Silent,Silent rs578017 4 84482387 [G/C] NM_001256422,NM_001256421,NM_032717 GPAT3,GPAT3,GPAT3 Silent,Silent,Silent rs10008545 4 84482817 [A/C] NM_001256422,NM_001256421,NM_032717 GPAT3,GPAT3,GPAT3 Silent,Silent,Silent rs10011103 4 84485400 [A/G] NM_001256422,NM_001256421,NM_032717 GPAT3,GPAT3,GPAT3 Silent,Silent,Silent rs1717631 4 84489471 [A/G] NM_001256422,NM_001256421,NM_032717 GPAT3,GPAT3,GPAT3 Silent,Silent,Silent rs17006903 4 84509737 [A/C] NM_001256422,NM_001256421,NM_032717 GPAT3,GPAT3,GPAT3 Silent,Silent,Silent rs1474250 4 84515775 [A/G] NM_001256422,NM_001256421,NM_032717 GPAT3,GPAT3,GPAT3 Silent,Silent,Silent rs3733328 4 84518315 [T/G] NM_001256422,NM_001256421,NM_032717 GPAT3,GPAT3,GPAT3 Silent,Silent,Silent rs3733329 4 84518558 [T/C] NM_001256422,NM_001256421,NM_032717 GPAT3,GPAT3,GPAT3 Silent,Silent,Silent rs1379974 4 84519076 [A/G] NM_001256422,NM_001256421,NM_032717 GPAT3,GPAT3,GPAT3 Silent,Silent,Silent rs1521531 4 84526275 [T/C] NM_001256422,NM_001256421,NM_032717 GPAT3,GPAT3,GPAT3 EXON Silent,Silent,Silent rs1521532 4 84526536 [T/C] NM_001256422,NM_001256421,NM_032717 GPAT3,GPAT3,GPAT3 EXON Silent,Silent,Silent rs1379977 4 84550759 [A/G] rs6818782 4 84552920 [A/G] rs17359809 4 84554429 [A/G] rs781443 4 84558656 [T/G] rs11099608 4 84560219 [A/G] rs1458642 4 84562362 [T/G] rs1458650 4 84566027 [T/G] rs2061408 4 84566072 [T/C] rs13151073 4 84569279 [A/G] rs1674338 4 84571718 [A/G] rs10516699 4 84572417 [A/G] rs17007085 4 84578678 [T/C] rs7694734 4 84580763 [A/C] rs13118676 4 84584157 [A/G] rs4693096 4 84584220 [T/C] rs1547507 4 84587179 [A/G] rs17360129 4 84588508 [T/C] rs11099613 4 84589904 [T/C] rs7694527 4 84597304 [T/C] rs17007149 4 84598254 [A/G] rs17007150 4 84598282 [T/C] rs7693390 4 84602082 [T/C] rs13117154 4 84603816 [T/C] rs17356247 4 84603852 [A/G] rs7340961 4 84604639 [T/C] rs6839928 4 84606737 [A/G] rs17356270 4 84606822 [T/C] rs7677300 4 84624474 [T/G] rs6849805 4 84626069 [A/C] rs10516696 4 84633401 [A/G] rs17007216 4 84636196 [A/G] rs6814874 4 84636731 [T/C] rs7660262 4 84639697 [T/G] rs4082474 4 84648524 [A/C] rs6821747 4 84652935 [T/C] rs1352436 4 84654205 [A/G] rs1458649 4 84658591 [T/C] rs2125426 4 84658805 [A/G] rs9307828 4 84659390 [A/G] rs10004130 4 84664343 [A/G] rs17007277 4 84669697 [T/C] rs1458647 4 84671227 [T/C] rs1488652 4 84673934 [T/C] rs4693641 4 84676270 [T/C] rs1993570 4 84684230 [A/G] rs17356652 4 84684277 [T/C] rs4629440 4 84700945 [T/C] rs4478182 4 84701093 [T/C] rs7679666 4 84706464 [A/G] rs11099616 4 84712638 [A/G] rs4693097 4 84712776 [T/C] rs17007373 4 84717030 [T/C] rs4693646 4 84721814 [A/G] rs13120080 4 84737580 [T/C] rs10018145 4 84750283 [A/G] rs17007418 4 84753412 [A/G] rs1352437 4 84755196 [A/C] rs13140644 4 84755605 [A/G] rs7689018 4 84759300 [A/G] rs11099621 4 84762151 [T/G] rs9999718 4 84762853 [T/C] rs4557253 4 84764167 [A/G] rs10005962 4 84764738 [T/C] rs17007466 4 84772839 [T/G] rs11939071 4 84777648 [T/G] rs17357139 4 84778595 [A/G] rs10003040 4 84779091 [T/C] rs10516704 4 84779231 [A/G] rs9307830 4 84779373 [A/G] rs2017394 4 84787315 [A/G] rs1994511 4 84788998 [A/G] rs10021381 4 84790267 [T/C] rs7696864 4 84791189 [A/G] rs721461 4 84793018 [T/C] rs1906578 4 84793814 [T/C] rs1906579 4 84793918 [A/G] rs1488656 4 84797545 [A/G] rs1818238 4 84798143 [T/C] rs1988722 4 84802420 [T/C] rs6822630 4 84808625 [A/G] rs13117766 4 84820870 [A/G] rs11735575 4 84823287 [T/G] rs2048005 4 84823736 [A/C] rs4106571 4 84825877 [A/C] rs6535510 4 84831724 [T/C] rs1505773 4 84837046 [T/C] rs1995597 4 84839094 [T/C] rs17007739 4 84841250 [T/G] rs17007745 4 84844152 [A/G] rs7656326 4 84853269 [A/G] rs6847383 4 84854633 [A/G] rs1827814 4 84854953 [A/G] rs12640485 4 84858835 [T/G] rs9992996 4 84870572 [T/C] rs12503076 4 84879860 [T/C] rs11099628 4 84880846 [T/C] rs11099629 4 84881138 [T/G] rs17007783 4 84881829 [A/G] rs2017802 4 84883024 [A/G] rs1857836 4 84883128 [T/C] rs12650954 4 84884893 [A/G] rs7670080 4 84887188 [A/C] rs905991 4 84893974 [A/G] NR_125909 LOC101928978 Silent rs1847819 4 84894991 [T/C] NR_125909 LOC101928978 Silent rs1876117 4 84901327 [T/G] NR_125909 LOC101928978 Silent rs9999681 4 84902964 [T/C] NR_125909 LOC101928978 Silent rs17007811 4 84907924 [T/C] NR_125909 LOC101928978 Silent rs2135284 4 84908159 [A/G] NR_125909 LOC101928978 Silent rs4693665 4 84909466 [T/C] NR_125909 LOC101928978 Silent rs4308354 4 84930230 [T/C] NR_125909 LOC101928978 Silent rs13149123 4 84939404 [T/C] NR_125909 LOC101928978 Silent rs17007862 4 84947233 [T/C] NR_125909 LOC101928978 Silent rs17007881 4 84953207 [A/G] NR_125909 LOC101928978 Silent rs1921880 4 84957198 [T/G] NR_125909 LOC101928978 Silent rs10516710 4 84957313 [T/C] NR_125909 LOC101928978 Silent rs2091745 4 84961080 [A/G] NR_125909 LOC101928978 Silent rs1921873 4 84964281 [A/C] NR_125909 LOC101928978 Silent rs17007921 4 84969104 [A/G] NR_125909 LOC101928978 Silent rs1921871 4 84970969 [A/G] NR_125909 LOC101928978 Silent rs1343881 4 84974648 [T/C] NR_125909 LOC101928978 Silent rs2178602 4 84975437 [A/G] NR_125909 LOC101928978 Silent rs12499536 4 84976857 [T/C] NR_125909 LOC101928978 Silent rs10000976 4 84978944 [T/C] NR_125909 LOC101928978 Silent rs17007945 4 84984952 [T/C] NR_125909 LOC101928978 Silent rs10022529 4 84991230 [T/C] NR_125909 LOC101928978 Silent rs7696640 4 85003358 [T/C] NR_125909 LOC101928978 Silent rs12508400 4 85005873 [T/C] NR_125909 LOC101928978 Silent rs1343762 4 85006975 [T/G] NR_125909 LOC101928978 Silent rs6855548 4 85007150 [T/C] NR_125909 LOC101928978 Silent rs13107199 4 85024046 [T/G] NR_125909 LOC101928978 Silent rs7683351 4 85029546 [A/G] NR_125909 LOC101928978 Silent rs1950128 4 85029894 [T/C] NR_125909 LOC101928978 Silent rs1921848 4 85036481 [T/G] NR_125909 LOC101928978 Silent rs1921847 4 85042254 [T/G] NR_125909 LOC101928978 Silent rs6820732 4 85054547 [A/G] NR_125909 LOC101928978 Silent rs1921867 4 85056551 [T/C] NR_125909 LOC101928978 Silent rs1950130 4 85068653 [A/G] NR_125909 LOC101928978 Silent rs7699547 4 85080176 [A/G] NR_125909 LOC101928978 Silent rs6815073 4 85080471 [T/G] NR_125909 LOC101928978 Silent rs10023423 4 85081980 [T/C] NR_125909 LOC101928978 Silent rs6824813 4 85082238 [T/C] NR_125909 LOC101928978 Silent rs4693676 4 85082294 [A/G] NR_125909 LOC101928978 Silent rs2178603 4 85090749 [A/G] NR_125909 LOC101928978 Silent rs6846132 4 85095855 [T/G] NR_125909 LOC101928978 Silent rs17008252 4 85097277 [A/G] NR_125909 LOC101928978 Silent rs17008262 4 85100353 [T/C] NR_125909 LOC101928978 Silent rs6825533 4 85118112 [T/C] NR_125909 LOC101928978 Silent rs13122998 4 85136552 [T/C] NR_125909 LOC101928978 Silent rs1319771 4 85138894 [A/G] NR_125909 LOC101928978 Silent rs6812243 4 85140339 [T/C] NR_125909 LOC101928978 Silent rs6827060 4 85149128 [A/G] NR_125909 LOC101928978 Silent rs4380514 4 85150623 [T/C] NR_125909 LOC101928978 Silent rs1532358 4 85159891 [A/G] NR_125909 LOC101928978 Silent rs1532357 4 85160070 [T/C] NR_125909 LOC101928978 Silent rs903521 4 85164682 [T/C] NR_125909 LOC101928978 Silent rs348703 4 85165015 [A/G] NR_125909 LOC101928978 Silent rs348701 4 85165381 [A/G] NR_125909 LOC101928978 Silent rs17008412 4 85169677 [A/G] NR_125909 LOC101928978 Silent rs17008416 4 85174676 [A/G] NR_125909 LOC101928978 Silent rs11725962 4 85174757 [T/C] NR_125909 LOC101928978 Silent rs10020148 4 85178344 [A/G] NR_125909 LOC101928978 Silent rs10020342 4 85178558 [A/G] NR_125909 LOC101928978 Silent rs10440439 4 85181277 [A/G] NR_125909 LOC101928978 Silent rs10030773 4 85189813 [T/C] NR_125909 LOC101928978 Silent rs6816852 4 85199286 [A/G] NR_125909 LOC101928978 Silent rs7662217 4 85201560 [T/C] NR_125909 LOC101928978 Silent rs1495151 4 85205214 [A/G] NR_125909 LOC101928978 Silent rs11932874 4 85206535 [A/G] NR_125909 LOC101928978 Silent rs1495145 4 85215142 [A/C] NR_125909 LOC101928978 Silent rs6850349 4 85244068 [T/C] rs17008568 4 85245699 [T/C] rs13109014 4 85260011 [T/C] rs882109 4 85260621 [T/C] rs1899392 4 85268860 [A/G] rs4264821 4 85272572 [T/C] rs1442163 4 85274557 [A/C] rs1442164 4 85274948 [A/G] rs6817184 4 85277790 [A/G] rs10021127 4 85281687 [T/G] rs17008673 4 85282675 [A/C] rs11729834 4 85283718 [T/C] rs17008692 4 85288111 [A/G] rs17008722 4 85292689 [T/C] rs1442173 4 85294388 [T/C] rs370171 4 85304092 [A/G] rs11934590 4 85305280 [T/C] rs385194 4 85309078 [A/G] rs6849720 4 85315581 [A/G] rs446951 4 85316658 [T/G] rs12650179 4 85324586 [T/C] rs4101237 4 85328262 [A/G] rs7686486 4 85339322 [A/G] rs17008894 4 85341562 [A/C] rs13434947 4 85342849 [A/G] rs1562147 4 85359985 [T/C] rs12233901 4 85360873 [T/C] rs1444976 4 85363446 [A/G] rs752402 4 85368880 [A/G] rs972863 4 85376683 [T/C] rs1444957 4 85377040 [T/C] rs17008957 4 85381582 [A/G] rs1822836 4 85387480 [A/G] rs7668923 4 85401169 [A/G] rs11721853 4 85407784 [T/C] rs17009011 4 85409571 [A/G] rs7670936 4 85414320 [A/G] rs2278671 4 85416797 [T/G] NM_006168 NKX6-1 Silent rs3806750 4 85419973 [T/C] rs1545330 4 85428178 [T/C] rs1017560 4 85434987 [T/G] rs7686198 4 85440241 [A/G] rs6812841 4 85447672 [A/G] rs6835003 4 85447778 [A/G] rs6849318 4 85449323 [T/C] rs1017557 4 85457113 [T/G] rs974130 4 85469315 [A/G] rs12642236 4 85475077 [T/C] rs7695015 4 85483258 [T/C] rs7699871 4 85483427 [T/C] rs11099650 4 85483950 [A/C] rs4449405 4 85485329 [A/G] rs17009161 4 85491947 [T/C] rs2868914 4 85496761 [T/C] rs11731505 4 85503575 [A/G] rs11097023 4 85505474 [T/C] NM_001263 CDS1 Silent rs3804184 4 85507021 [A/G] NM_001263 CDS1 Silent rs17367226 4 85510643 [A/G] NM_001263 CDS1 Silent rs2868919 4 85520643 [A/G] NM_001263 CDS1 Silent rs2165786 4 85532915 [T/C] NM_001263 CDS1 Silent rs1020278 4 85532930 [A/G] NM_001263 CDS1 Silent rs10014792 4 85536148 [T/C] NM_001263 CDS1 Silent rs10020892 4 85537820 [A/G] NM_001263 CDS1 Silent rs4490450 4 85545644 [A/G] NM_001263 CDS1 Silent rs17376090 4 85546826 [T/C] NM_001263 CDS1 Silent rs6829806 4 85558840 [A/C] NM_001263 CDS1 Silent rs1946998 4 85566809 [A/G] NM_001263 CDS1 Silent rs17367775 4 85569930 [A/C] NM_001263 CDS1 EXON Silent rs1838038 4 85570364 [A/G] NM_001263 CDS1 EXON Silent rs6827228 4 85570767 [T/C] NM_001263 CDS1 EXON Silent rs1372971 4 85571339 [A/G] NM_001263 CDS1 EXON Silent rs1120 4 85572374 [A/G] NM_001263 CDS1 EXON Silent rs17367858 4 85583567 [T/C] rs17009177 4 85593136 [T/C] NM_014991 WDFY3 EXON Silent rs10049510 4 85603220 [T/C] NM_014991 WDFY3 Silent rs3747680 4 85612737 [A/G] NM_014991 WDFY3 Silent rs17368018 4 85612894 [T/C] NM_014991 WDFY3 EXON Missense_I3032V rs35617206 4 85620879 [T/G] NM_014991 WDFY3 Silent rs6816534 4 85621772 [A/G] NM_014991 WDFY3 Silent rs1838039 4 85625701 [A/G] NM_014991 WDFY3 Silent rs10022652 4 85629407 [T/C] NM_014991 WDFY3 Silent rs13108722 4 85634488 [T/C] NM_014991 WDFY3 Silent rs10516727 4 85640591 [A/G] NM_014991 WDFY3 Silent rs17009231 4 85644051 [A/G] NM_014991 WDFY3 Silent rs4408954 4 85651685 [T/C] NM_014991 WDFY3 Silent rs17009237 4 85662023 [T/C] NM_014991 WDFY3 Silent rs10034853 4 85669238 [T/C] NM_014991 WDFY3 Silent rs17009276 4 85695743 [A/C] NM_014991 WDFY3 Silent rs6821491 4 85713972 [T/C] NM_014991 WDFY3 Silent rs6858666 4 85729936 [T/C] NM_014991 WDFY3 Silent rs7681742 4 85730752 [T/C] NM_014991 WDFY3 Silent rs6531775 4 85730914 [T/C] NM_014991 WDFY3 Silent rs1484662 4 85734049 [A/G] NM_014991 WDFY3 Silent rs17009317 4 85769856 [A/G] NM_014991 WDFY3 Silent rs1872321 4 85770794 [T/C] NM_014991 WDFY3 Silent rs11936391 4 85779738 [T/C] NM_014991 WDFY3 Silent rs11726635 4 85782946 [A/G] NM_014991 WDFY3 Silent rs12501525 4 85786828 [T/C] NM_014991 WDFY3 Silent rs13143466 4 85801827 [T/C] NM_014991 WDFY3 Silent rs11097026 4 85803607 [A/C] NM_014991 WDFY3 Silent rs10029496 4 85824232 [A/C] NM_014991 WDFY3 Silent rs12501332 4 85827192 [T/C] NM_014991 WDFY3 Silent rs6833661 4 85839095 [T/C] NM_014991 WDFY3 Silent rs10516733 4 85844157 [A/G] NM_014991 WDFY3 Silent rs6848127 4 85858329 [T/C] NM_014991 WDFY3 Silent rs7673892 4 85859997 [T/G] NM_014991 WDFY3 Silent rs4627854 4 85872414 [A/G] NM_014991 WDFY3 Silent rs10009540 4 85881218 [T/G] NM_014991 WDFY3 Silent rs4590017 4 85898741 [A/G] NR_152772,NR_152773,NR_152775,NR_152774,NR_152771,NR_152776,NR_015359,NR_152781,NR_152780,NR_152778,NR_152779,NR_152782 WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4533765 4 85915570 [T/C] NR_152772,NR_152773,NR_152775,NR_152774,NR_152771,NR_152776,NR_015359,NR_152781,NR_152780,NR_152778,NR_152779,NR_152782 WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2,WDFY3-AS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6824972 4 85941335 [T/G] rs4287999 4 85974024 [T/C] rs10516730 4 85981276 [T/C] rs4129430 4 85993738 [T/C] rs10516731 4 85998783 [A/G] rs11097033 4 86000455 [A/G] rs4235071 4 86005206 [T/C] rs6835154 4 86009525 [T/C] rs4558866 4 86021602 [A/G] rs4507353 4 86024239 [T/C] rs11941410 4 86033441 [A/C] rs10034520 4 86034744 [T/C] rs17009476 4 86036723 [A/G] rs17009493 4 86042277 [T/C] rs6820757 4 86044561 [T/C] rs6835768 4 86049136 [A/G] rs13145163 4 86057003 [T/C] rs2869268 4 86064719 [A/G] rs11728848 4 86078683 [A/G] rs2869291 4 86080861 [T/G] rs17009514 4 86088655 [A/G] rs7349600 4 86094786 [A/G] rs12507778 4 86098946 [A/C] rs12510879 4 86101484 [A/C] rs6822829 4 86101771 [A/G] rs17009586 4 86107271 [A/G] rs2869302 4 86109620 [T/C] rs7666306 4 86129563 [A/G] rs6818991 4 86153942 [A/G] rs6841256 4 86167397 [A/G] rs11730221 4 86167708 [T/G] rs2869329 4 86167996 [A/G] rs12504718 4 86178448 [A/G] rs11097048 4 86178701 [A/G] rs7673714 4 86191083 [T/C] rs11732437 4 86210281 [A/G] rs7678568 4 86222977 [T/C] rs11932123 4 86251698 [A/G] rs434193 4 86253489 [T/C] rs17010018 4 86263649 [T/C] rs1955237 4 86264971 [T/C] rs342944 4 86266527 [A/G] rs1817149 4 86276070 [T/C] rs11938951 4 86288423 [T/C] rs391925 4 86289106 [A/G] rs403870 4 86289320 [A/G] rs412856 4 86289637 [T/C] rs10222882 4 86292692 [T/G] rs6842048 4 86292752 [A/G] rs1377362 4 86294733 [A/G] rs9306997 4 86297661 [A/G] rs7694853 4 86299663 [A/C] rs1377364 4 86300133 [T/C] rs381032 4 86309824 [A/G] rs384878 4 86321876 [T/C] rs405074 4 86324046 [T/G] rs1453071 4 86324520 [A/G] rs340185 4 86335426 [T/G] rs744597 4 86337028 [T/C] rs4693115 4 86339453 [A/G] rs340192 4 86339956 [A/G] rs168153 4 86340696 [T/C] rs340199 4 86350683 [A/C] rs340200 4 86351156 [T/C] rs975967 4 86353091 [A/G] rs13118367 4 86357821 [A/G] rs1481775 4 86358621 [T/G] rs10516748 4 86366812 [T/C] rs17010244 4 86369449 [T/C] rs9995572 4 86381967 [T/G] rs1383972 4 86384329 [A/G] rs28539206 4 86394813 [T/C] rs7679833 4 86397676 [T/C] NM_001025616 ARHGAP24 Silent rs10034597 4 86397877 [A/G] NM_001025616 ARHGAP24 Silent rs11097055 4 86414621 [A/G] NM_001025616 ARHGAP24 Silent rs13434421 4 86420622 [A/G] NM_001025616 ARHGAP24 Silent rs10015995 4 86426882 [A/G] NM_001025616 ARHGAP24 Silent rs4611924 4 86432381 [A/C] NM_001025616 ARHGAP24 Silent rs1383976 4 86434204 [A/G] NM_001025616 ARHGAP24 Silent rs9307000 4 86434268 [A/G] NM_001025616 ARHGAP24 Silent rs9985756 4 86436599 [A/G] NM_001025616 ARHGAP24 Silent rs4693701 4 86437529 [A/G] NM_001025616 ARHGAP24 Silent rs2078049 4 86437794 [T/G] NM_001025616 ARHGAP24 Silent rs17387199 4 86440758 [A/C] NM_001025616 ARHGAP24 Silent rs17010337 4 86443925 [A/G] NM_001025616 ARHGAP24 Silent rs10020489 4 86445949 [A/G] NM_001025616 ARHGAP24 Silent rs6845803 4 86455224 [T/C] NM_001025616 ARHGAP24 Silent rs11942163 4 86461983 [T/G] NM_001025616 ARHGAP24 Silent rs11097059 4 86463980 [A/C] NM_001025616 ARHGAP24 Silent rs1545823 4 86464117 [T/C] NM_001025616 ARHGAP24 Silent rs6829120 4 86467056 [A/G] NM_001025616 ARHGAP24 Silent rs2869356 4 86475051 [T/C] NM_001025616 ARHGAP24 Silent rs12510597 4 86478104 [T/G] NM_001025616 ARHGAP24 Silent rs964837 4 86482468 [A/G] NM_001025616 ARHGAP24 Silent rs2128101 4 86487089 [T/C] NM_001025616 ARHGAP24 Silent rs17010470 4 86492246 [A/G] NM_001025616 ARHGAP24 Silent rs11930449 4 86498937 [A/G] NM_001025616 ARHGAP24 Silent rs1384137 4 86501891 [A/G] NM_001025616 ARHGAP24 Silent rs17010510 4 86506532 [T/C] NM_001025616 ARHGAP24 Silent rs1161262 4 86508815 [T/C] NM_001025616 ARHGAP24 Silent rs2623770 4 86510607 [A/C] NM_001025616 ARHGAP24 Silent rs13149991 4 86520349 [A/G] NM_001025616 ARHGAP24 Silent rs1482090 4 86523580 [A/G] NM_001025616 ARHGAP24 Silent rs6849280 4 86528170 [T/G] NM_001025616 ARHGAP24 Silent rs13103706 4 86533932 [A/G] NM_001025616 ARHGAP24 Silent rs17010548 4 86535894 [A/G] NM_001025616 ARHGAP24 Silent rs12504294 4 86549594 [T/G] NM_001025616 ARHGAP24 Silent rs1482088 4 86559173 [A/C] NM_001025616 ARHGAP24 Silent rs1384135 4 86565198 [A/G] NM_001025616 ARHGAP24 Silent rs7672782 4 86579977 [A/G] NM_001025616 ARHGAP24 Silent rs4693122 4 86581005 [A/G] NM_001025616 ARHGAP24 Silent rs10516752 4 86592742 [T/C] NM_001025616 ARHGAP24 Silent rs1482097 4 86594072 [A/C] NM_001025616 ARHGAP24 Silent rs1026873 4 86601669 [T/C] NM_001025616 ARHGAP24 Silent rs7698203 4 86604729 [T/G] NM_001025616 ARHGAP24 Silent rs6823441 4 86614203 [T/C] NM_001025616 ARHGAP24 Silent rs10017047 4 86615391 [A/G] NM_001025616 ARHGAP24 Silent rs7677064 4 86620884 [T/C] NM_001025616 ARHGAP24 Silent rs1482085 4 86630512 [A/G] NM_001025616 ARHGAP24 Silent rs4413396 4 86632771 [A/G] NM_001025616 ARHGAP24 Silent rs6531859 4 86637908 [A/G] NM_001025616 ARHGAP24 Silent rs343860 4 86644336 [T/C] NM_001025616 ARHGAP24 Silent rs1482094 4 86650019 [T/C] NM_001025616 ARHGAP24 Silent rs10516754 4 86650763 [T/C] NM_001025616 ARHGAP24 Silent rs2062098 4 86652248 [T/C] NM_001025616 ARHGAP24 Silent rs1482091 4 86653361 [A/G] NM_001025616 ARHGAP24 Silent rs994285 4 86659114 [T/G] NM_001025616 ARHGAP24 Silent rs13106553 4 86669762 [A/G] NM_001025616 ARHGAP24 Silent rs6848047 4 86675725 [T/C] NM_001025616 ARHGAP24 Silent rs4693735 4 86677107 [T/C] NM_001025616 ARHGAP24 Silent rs11736641 4 86683729 [T/G] NM_001025616 ARHGAP24 Silent rs13150113 4 86689557 [T/G] NM_001025616 ARHGAP24 Silent rs11945319 4 86691595 [A/G] NM_001025616 ARHGAP24 Silent rs6831420 4 86692665 [A/G] NM_001025616 ARHGAP24 Silent rs10516756 4 86703976 [T/C] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs7670874 4 86704339 [A/C] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs10516757 4 86704797 [A/G] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs1452681 4 86705664 [T/C] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs9307010 4 86706193 [A/G] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs10516758 4 86706902 [T/C] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs7662174 4 86709899 [T/G] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs17010925 4 86713124 [T/G] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs7687906 4 86715312 [T/G] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs17010957 4 86719165 [T/C] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs12504839 4 86720955 [A/G] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs7689056 4 86723173 [A/G] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs1452676 4 86725502 [T/G] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs17395916 4 86726240 [A/G] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs6815441 4 86730514 [T/C] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs4693128 4 86730714 [T/C] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs12512001 4 86732728 [T/C] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs12498568 4 86739805 [T/C] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs1823762 4 86744000 [A/G] NM_001025616,NM_001042669,NM_001346093 ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent rs345363 4 86750699 [T/C] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs17011024 4 86751384 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs3796625 4 86751718 [T/C] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs6844781 4 86752397 [A/C] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs345367 4 86754638 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs345370 4 86756230 [T/C] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs10008894 4 86763097 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs345328 4 86763901 [T/C] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs6834349 4 86768945 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs7672187 4 86776488 [T/C] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs2601864 4 86795362 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs10032626 4 86808963 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs6817562 4 86810287 [T/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs10009525 4 86812285 [T/C] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs1016510 4 86819377 [A/C] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs10023650 4 86821509 [T/C] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs7696763 4 86829529 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs723570 4 86832756 [T/C] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs346510 4 86836381 [T/C] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs10006487 4 86837535 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs9307013 4 86837843 [T/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs17011210 4 86841067 [T/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs346521 4 86847640 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent rs346498 4 86851560 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805,NM_031305 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 EXON Silent,Silent,Silent,Silent,Silent rs346500 4 86853558 [T/C] NM_001025616,NM_001042669,NM_001346093,NM_001287805,NM_031305 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent,Silent rs17011217 4 86856661 [T/C] NM_001025616,NM_001042669,NM_001346093,NM_001287805,NM_031305 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent,Silent rs17011240 4 86860823 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805,NM_031305 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent,Silent rs2665869 4 86864518 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805,NM_031305 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent,Silent rs13110329 4 86871282 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805,NM_031305 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent,Silent rs346480 4 86880673 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805,NM_031305 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent,Silent rs12498346 4 86891199 [T/C] NM_001025616,NM_001042669,NM_001346093,NM_001287805,NM_031305 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent,Silent rs11724681 4 86912951 [A/G] NM_001025616,NM_001042669,NM_001346093,NM_001287805,NM_031305 ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24,ARHGAP24 Silent,Silent,Silent,Silent,Silent rs2575676 4 86930207 [T/G] rs7438872 4 86930609 [T/C] rs7439032 4 86931091 [T/C] rs2589525 4 86931482 [A/G] rs4640664 4 86932486 [T/C] rs17011297 4 86933060 [T/G] rs2589523 4 86933202 [A/G] rs2575675 4 86935890 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1201 4 86936468 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs958 4 86937874 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2589514 4 86940532 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3775167 4 86946141 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2043649 4 86948942 [A/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3775173 4 86954867 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10856856 4 86956026 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6815306 4 86966327 [A/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17011341 4 86975062 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3775182 4 86979583 [T/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3775187 4 86983232 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1469869 4 86990027 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4414944 4 87018488 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10009993 4 87021505 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12644947 4 87021938 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12640395 4 87023394 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12505595 4 87028072 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs5006575 4 87037379 [T/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4403040 4 87038481 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7689936 4 87041318 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12647506 4 87054813 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4352468 4 87062363 [A/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10001480 4 87074032 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6822478 4 87076360 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10035072 4 87082793 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7440491 4 87084039 [A/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7678480 4 87087320 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1903360 4 87095840 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1460761 4 87096662 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1460763 4 87098956 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11097100 4 87108742 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10034428 4 87122922 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2904090 4 87132771 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1599313 4 87135124 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12650052 4 87138738 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10010011 4 87139714 [A/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753,NR_110879 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,LOC101929064 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17011540 4 87150469 [T/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17011547 4 87151567 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6825506 4 87168939 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10516770 4 87172098 [A/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17011617 4 87176620 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11725943 4 87180112 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2035058 4 87185006 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6855169 4 87190830 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17011655 4 87197433 [T/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10019269 4 87206153 [A/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1460751 4 87219895 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17408881 4 87225468 [T/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7655217 4 87231768 [A/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4693763 4 87231849 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10213444 4 87232968 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4299551 4 87235780 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6531915 4 87240020 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2290882 4 87250736 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4693142 4 87252259 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7689808 4 87254477 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13132206 4 87255851 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4608765 4 87259268 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7688651 4 87259805 [T/C] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6531925 4 87263901 [T/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11097109 4 87269343 [A/G] NM_138980,NM_138982,NM_001318068,NM_001363657,NM_001351624,NM_001351625,NM_001318069,NM_001318067,NM_002753 MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10,MAPK10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10008238 4 87282216 [T/C] NM_001318068,NM_002753 MAPK10,MAPK10 Silent,Silent rs12644920 4 87287934 [A/C] NM_001318068,NM_002753 MAPK10,MAPK10 Silent,Silent rs13115030 4 87296065 [A/C] NM_002753 MAPK10 Silent rs2904095 4 87321260 [T/C] NM_002753 MAPK10 Silent rs4235080 4 87322336 [T/C] NM_002753 MAPK10 Silent rs17418062 4 87336776 [T/C] NM_002753 MAPK10 Silent rs12507758 4 87351740 [T/C] NM_002753 MAPK10 Silent rs4488910 4 87362834 [T/C] NM_002753 MAPK10 Silent rs12503051 4 87369063 [A/G] NM_002753 MAPK10 Silent rs7658485 4 87389117 [T/C] rs4693147 4 87404608 [A/G] rs11947775 4 87407518 [T/C] rs4607180 4 87457636 [A/G] rs4529013 4 87463813 [A/G] rs6847139 4 87465741 [A/G] rs4478147 4 87473776 [A/G] rs4277747 4 87500298 [T/G] rs12508626 4 87514712 [A/C] rs7660964 4 87517609 [T/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs9993042 4 87530343 [A/C] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs6531932 4 87541252 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs10023787 4 87542149 [T/C] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs9307020 4 87543847 [T/C] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs17011965 4 87551471 [T/C] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs10029671 4 87552903 [T/C] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs7693617 4 87561736 [T/C] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs2170427 4 87566027 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs1021101 4 87580297 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs7654160 4 87593116 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs1187212 4 87603929 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs17011988 4 87603992 [T/C] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs980637 4 87605335 [T/C] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs1212166 4 87626028 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs1420621 4 87632672 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs4693780 4 87641219 [T/C] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs12508339 4 87644842 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs10024860 4 87656992 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs10033679 4 87659465 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs7664860 4 87664854 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs13112139 4 87667171 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs10029565 4 87670795 [A/C] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs2054593 4 87673221 [T/C] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs1420624 4 87679642 [A/C] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs710832 4 87684031 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 EXON Synonymous_P1044P,Synonymous_P1235P,Synonymous_P1235P,Synonymous_P1216P rs11097118 4 87689268 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs2230600 4 87690998 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 EXON Missense_I1331M,Missense_I1527M,Missense_I1522M,Missense_I1503M rs12499471 4 87696476 [A/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 EXON Synonymous_T1696T,Synonymous_T1892T,Synonymous_T1887T,Synonymous_T1868T rs989902 4 87706506 [T/G] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 EXON Missense_Y1890D,Missense_Y2086D,Missense_Y2081D,Missense_Y2062D rs17694112 4 87728676 [A/C] NM_080684,NM_080685,NM_080683,NM_006264 PTPN13,PTPN13,PTPN13,PTPN13 Silent,Silent,Silent,Silent rs10016456 4 87737110 [A/G] rs10000226 4 87738967 [T/C] rs10009590 4 87741699 [T/C] rs7688011 4 87743956 [A/G] rs7688019 4 87743984 [T/G] rs7662996 4 87748582 [T/G] NM_197965 SLC10A6 Silent rs4386565 4 87754466 [T/C] NM_197965 SLC10A6 EXON Synonymous_Q163Q rs7678571 4 87754713 [A/G] NM_197965 SLC10A6 Silent rs13147739 4 87759673 [A/G] NM_197965 SLC10A6 Silent rs6531935 4 87760103 [A/G] NM_197965 SLC10A6 Silent rs13106574 4 87769929 [T/C] NM_197965 SLC10A6 EXON Missense_I114V rs17694522 4 87770252 [A/G] NM_197965 SLC10A6 EXON Missense_S6F rs8180256 4 87773193 [A/G] rs727143 4 87793546 [T/C] rs10015508 4 87794302 [T/C] rs4508849 4 87795589 [A/G] rs11737837 4 87795755 [A/C] rs1374934 4 87798196 [A/G] NM_144645 C4orf36 Silent rs6811350 4 87799216 [A/G] NM_144645 C4orf36 Silent rs2121871 4 87800577 [T/C] NM_144645 C4orf36 Silent rs1550931 4 87809387 [T/G] NM_144645 C4orf36 EXON Missense_S36Y rs11938345 4 87812621 [T/C] NM_144645 C4orf36 EXON Missense_S18N rs1868244 4 87815387 [A/G] rs10029698 4 87816557 [A/G] rs3113494 4 87832601 [A/G] rs17751557 4 87834607 [A/G] rs28458234 4 87836016 [A/C] rs1584345 4 87839727 [A/C] rs7657530 4 87852108 [T/G] NR_038841 AFF1-AS1 Silent rs6836128 4 87863770 [T/C] NM_001166693 AFF1 Silent rs1992876 4 87873164 [A/G] NM_001166693 AFF1 Silent rs725030 4 87877291 [A/G] NM_001166693 AFF1 Silent rs965824 4 87880096 [A/G] NM_001166693 AFF1 Silent rs4274814 4 87883837 [T/C] NM_001166693 AFF1 Silent rs12651081 4 87884766 [A/G] NM_001166693 AFF1 Silent rs6531941 4 87895960 [T/C] NM_001166693 AFF1 Silent rs6855627 4 87898302 [A/G] NM_001166693 AFF1 Silent rs17012253 4 87919706 [A/G] NM_001166693 AFF1 Silent rs340638 4 87928204 [T/C] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 EXON Silent,Silent,Silent,Silent rs340636 4 87930760 [T/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs340641 4 87951393 [T/C] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs6831823 4 87954827 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs10032200 4 87955141 [A/C] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs340628 4 87956886 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs375795 4 87972465 [T/C] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs6819155 4 87976178 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs3775229 4 87978626 [A/C] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs4693802 4 87979212 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs384059 4 87982790 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs10006308 4 87983880 [A/C] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs10489045 4 87994787 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs17605615 4 87996745 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs236996 4 88005203 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs236675 4 88010601 [T/C] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs3755985 4 88024738 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs17012461 4 88029025 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs3822041 4 88030486 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs447990 4 88033352 [T/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs19026 4 88041256 [T/C] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs7699407 4 88052183 [A/C] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs342467 4 88052219 [T/C] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 Silent,Silent,Silent,Silent rs11721639 4 88052344 [T/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 EXON Missense_V1025G,Missense_V656G,Missense_V1018G,Missense_V1018G rs1408 4 88057353 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 EXON Silent,Silent,Silent,Silent rs342462 4 88057481 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 EXON Silent,Silent,Silent,Silent rs342461 4 88058472 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 EXON Silent,Silent,Silent,Silent rs342459 4 88059415 [A/G] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 EXON Silent,Silent,Silent,Silent rs342458 4 88060025 [A/C] NM_001166693,NM_001313960,NM_001313959,NM_005935 AFF1,AFF1,AFF1,AFF1 EXON Silent,Silent,Silent,Silent rs2926511 4 88062611 [A/G] rs17012512 4 88067504 [T/C] rs17012513 4 88067584 [T/G] rs4693803 4 88068531 [T/G] rs1466364 4 88068599 [A/C] rs17012516 4 88069143 [A/G] rs13145898 4 88073178 [A/G] rs6840470 4 88082526 [T/C] NR_120447,NM_001292003,NM_001292007,NM_001292006,NM_020803 KLHL8,KLHL8,KLHL8,KLHL8,KLHL8 EXON Silent,Silent,Silent,Silent,Silent rs3204865 4 88082846 [A/G] NR_120447,NM_001292003,NM_001292007,NM_001292006,NM_020803 KLHL8,KLHL8,KLHL8,KLHL8,KLHL8 EXON Silent,Silent,Silent,Silent,Silent rs3193672 4 88083107 [T/C] NR_120447,NM_001292003,NM_001292007,NM_001292006,NM_020803 KLHL8,KLHL8,KLHL8,KLHL8,KLHL8 EXON Silent,Silent,Silent,Silent,Silent rs17754933 4 88087832 [A/G] NR_120447,NM_001292003,NM_001292007,NM_001292006,NM_020803 KLHL8,KLHL8,KLHL8,KLHL8,KLHL8 Silent,Silent,Silent,Silent,Silent rs964739 4 88088507 [A/G] NR_120447,NM_001292003,NM_001292007,NM_001292006,NM_020803 KLHL8,KLHL8,KLHL8,KLHL8,KLHL8 Silent,Silent,Silent,Silent,Silent rs6531956 4 88117272 [T/C] NR_120447,NM_001292003,NM_001292007,NM_001292006,NM_020803 KLHL8,KLHL8,KLHL8,KLHL8,KLHL8 Silent,Silent,Silent,Silent,Silent rs6811473 4 88134989 [T/C] NR_120447,NM_001292003,NM_001292007,NM_001292006,NM_020803 KLHL8,KLHL8,KLHL8,KLHL8,KLHL8 Silent,Silent,Silent,Silent,Silent rs11932935 4 88135777 [T/C] NR_120447,NM_001292003,NM_001292007,NM_001292006,NM_020803 KLHL8,KLHL8,KLHL8,KLHL8,KLHL8 Silent,Silent,Silent,Silent,Silent rs6834470 4 88148812 [A/C] rs6531964 4 88148895 [A/G] rs6835257 4 88149021 [A/G] rs11097130 4 88156939 [A/C] rs13137873 4 88159429 [T/C] rs7668684 4 88159940 [A/G] rs10006766 4 88160018 [A/G] rs4345139 4 88162693 [A/G] rs4134363 4 88162837 [A/G] rs6847980 4 88180631 [T/G] rs3923441 4 88189651 [T/G] rs7668929 4 88190169 [A/G] rs7699556 4 88191100 [T/C] rs7436142 4 88198088 [T/G] rs6531968 4 88199484 [T/G] rs4693811 4 88200095 [T/C] rs10084835 4 88211056 [A/G] rs4607179 4 88214144 [A/C] rs13133311 4 88217223 [A/G] rs13102451 4 88220112 [A/G] rs11945520 4 88224998 [T/C] NM_001136230,NM_178135 HSD17B13,HSD17B13 EXON Silent,Silent rs11735092 4 88226231 [T/C] NM_001136230,NM_178135 HSD17B13,HSD17B13 EXON Silent,Silent rs6850131 4 88226480 [A/C] NM_001136230,NM_178135 HSD17B13,HSD17B13 Silent,Silent rs10022237 4 88228228 [T/C] NM_001136230,NM_178135 HSD17B13,HSD17B13 Silent,Silent rs6531972 4 88230737 [A/C] NM_001136230,NM_178135 HSD17B13,HSD17B13 Silent,Silent rs9992651 4 88232510 [A/G] NM_001136230,NM_178135 HSD17B13,HSD17B13 Silent,Silent rs7698406 4 88234593 [T/C] NM_001136230,NM_178135 HSD17B13,HSD17B13 Silent,Silent rs7678047 4 88244210 [A/G] rs6531977 4 88246162 [T/G] rs11939901 4 88256127 [T/C] rs7698689 4 88264614 [A/G] NM_016245 HSD17B11 Silent rs11097131 4 88266006 [T/C] NM_016245 HSD17B11 Silent rs11734330 4 88274740 [T/G] NM_016245 HSD17B11 Silent rs6845304 4 88280502 [T/C] NM_016245 HSD17B11 Silent rs10028441 4 88290265 [A/G] NM_016245 HSD17B11 Silent rs11737402 4 88291439 [A/G] NM_016245 HSD17B11 Silent rs6531985 4 88293887 [A/G] NM_016245 HSD17B11 EXON Synonymous_V177V rs10222732 4 88295008 [C/G] NM_016245 HSD17B11 Silent rs7682516 4 88304358 [T/G] NM_016245 HSD17B11 Silent rs11097148 4 88308415 [T/G] NM_016245 HSD17B11 Silent rs13138404 4 88312504 [T/C] rs12644152 4 88313179 [A/G] rs11097151 4 88326380 [T/G] rs6827817 4 88330987 [A/G] rs11936273 4 88335508 [A/G] rs11936366 4 88335754 [A/G] rs10017282 4 88347368 [T/C] NM_001248011,NM_024047,NM_198038 NUDT9,NUDT9,NUDT9 Silent,Silent,Silent rs7673763 4 88349022 [T/G] NM_001248011,NM_024047,NM_198038 NUDT9,NUDT9,NUDT9 Silent,Silent,Silent rs11097155 4 88349200 [T/C] NM_001248011,NM_024047,NM_198038 NUDT9,NUDT9,NUDT9 Silent,Silent,Silent rs7690728 4 88356799 [T/C] NM_001248011,NM_024047,NM_198038 NUDT9,NUDT9,NUDT9 Silent,Silent,Silent rs13119333 4 88365083 [T/C] NM_001248011,NM_024047,NM_198038 NUDT9,NUDT9,NUDT9 Silent,Silent,Silent rs9968511 4 88381080 [T/C] rs9307036 4 88382475 [A/G] rs4405983 4 88386769 [T/C] rs10024099 4 88389081 [A/G] rs7683311 4 88392755 [A/C] rs9994839 4 88393780 [T/G] rs4693164 4 88398749 [T/C] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 Silent,Silent,Silent,Silent rs4610302 4 88400110 [A/G] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 Silent,Silent,Silent,Silent rs10461161 4 88404126 [A/C] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 Silent,Silent,Silent,Silent rs3763392 4 88415884 [A/C] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 Silent,Silent,Silent,Silent rs9993980 4 88424737 [T/C] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 Silent,Silent,Silent,Silent rs2869678 4 88433880 [A/G] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 Silent,Silent,Silent,Silent rs1870881 4 88435789 [A/G] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 Silent,Silent,Silent,Silent rs10001608 4 88437710 [T/C] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 Silent,Silent,Silent,Silent rs4693829 4 88438011 [A/C] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 Silent,Silent,Silent,Silent rs12643464 4 88438520 [T/C] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 Silent,Silent,Silent,Silent rs12640408 4 88439106 [A/G] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 Silent,Silent,Silent,Silent rs17012782 4 88443685 [A/G] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 Silent,Silent,Silent,Silent rs17012809 4 88447551 [T/C] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 Silent,Silent,Silent,Silent rs2011326 4 88448026 [A/C] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 Silent,Silent,Silent,Silent rs1049539 4 88450348 [T/C] NM_001291976,NM_001291977,NM_004684,NM_001128310 SPARCL1,SPARCL1,SPARCL1,SPARCL1 EXON Silent,Silent,Silent,Silent rs17012830 4 88451096 [T/C] rs1031794 4 88451182 [T/C] rs1031796 4 88451579 [A/C] rs11943726 4 88455621 [T/C] rs10027979 4 88456441 [T/C] rs4693841 4 88466135 [T/C] rs9762628 4 88467172 [A/C] rs7685612 4 88468386 [A/G] rs1381633 4 88468852 [A/G] rs16996086 4 88471575 [A/C] rs13144424 4 88474171 [A/G] rs2904166 4 88477532 [T/C] rs1462372 4 88478750 [T/C] rs7435692 4 88489929 [A/C] rs2199458 4 88491716 [A/G] rs6822632 4 88502642 [A/G] rs2869680 4 88502776 [T/C] rs13435625 4 88505945 [A/G] rs13137502 4 88509540 [T/C] rs4693847 4 88509940 [T/C] rs6532012 4 88520379 [A/C] rs2615485 4 88522478 [T/C] rs2615487 4 88530463 [T/C] NM_014208 DSPP Silent rs13131929 4 88533441 [T/C] NM_014208 DSPP Silent rs3750025 4 88534065 [A/G] NM_014208 DSPP EXON Missense_D243N rs2736982 4 88534235 [A/G] NM_014208 DSPP EXON Synonymous_S299S rs2615489 4 88537737 [A/G] NM_014208 DSPP EXON Silent rs10016823 4 88539776 [T/C] rs10028688 4 88539948 [T/C] rs1381626 4 88552784 [A/G] rs6532013 4 88553414 [A/G] rs2045743 4 88553549 [A/G] rs2627657 4 88554115 [A/G] rs2627669 4 88564721 [T/C] rs2627696 4 88567295 [T/C] rs2904169 4 88569583 [T/G] rs1462367 4 88570528 [T/C] rs1545735 4 88578487 [T/C] NM_004407,NM_001079911 DMP1,DMP1 Silent,Silent rs10019009 4 88583135 [A/T] NM_004407,NM_001079911 DMP1,DMP1 EXON Missense_S69C,Missense_S53C rs10034250 4 88601464 [T/C] rs11946697 4 88604547 [A/C] rs11097166 4 88611344 [A/G] rs17012948 4 88615772 [T/C] rs2869704 4 88629174 [T/C] rs17012992 4 88631046 [T/C] rs7680291 4 88638522 [T/G] rs10016081 4 88640064 [T/C] rs4416440 4 88652577 [T/C] rs2732171 4 88655984 [A/G] rs7661141 4 88665977 [A/G] rs7685567 4 88665994 [T/C] rs17013057 4 88673568 [A/G] rs2627704 4 88677931 [T/C] rs4693868 4 88678096 [T/G] rs17013067 4 88680835 [T/C] rs2627723 4 88681801 [A/C] rs2627714 4 88687693 [A/G] rs4693869 4 88689765 [A/G] rs7661149 4 88696086 [A/G] rs2100889 4 88698345 [T/C] rs6857696 4 88701522 [T/C] rs2045839 4 88703641 [T/C] rs12650760 4 88705132 [T/C] rs13136331 4 88707081 [T/C] rs17761748 4 88709783 [A/C] rs2732166 4 88710784 [A/G] rs13137552 4 88715324 [T/C] rs2616262 4 88723210 [T/G] NM_004967 IBSP Silent rs1870964 4 88724600 [A/C] NM_004967 IBSP Silent rs3805374 4 88724967 [T/C] NM_004967 IBSP Silent rs17013175 4 88726959 [A/G] NM_004967 IBSP Silent rs1381965 4 88728904 [A/C] NM_004967 IBSP Silent rs1054627 4 88732692 [A/G] NM_004967 IBSP EXON Missense_G195E rs13144371 4 88732746 [A/G] NM_004967 IBSP EXON Missense_D213G rs17013181 4 88732763 [A/G] NM_004967 IBSP EXON Missense_R219G rs17013182 4 88732874 [A/G] NM_004967 IBSP EXON Missense_T256A rs1054628 4 88732911 [T/C] NM_004967 IBSP EXON Missense_A268V rs17013187 4 88733531 [T/C] NM_004967 IBSP EXON Silent rs7681895 4 88742318 [T/C] rs13117929 4 88746734 [A/G] NM_001184694 MEPE Silent rs10007111 4 88749701 [A/G] NM_001184694 MEPE Silent rs11097172 4 88752878 [T/C] NM_001184694 MEPE Silent rs1585616 4 88753045 [T/C] NM_001184694 MEPE Silent rs17013212 4 88754060 [T/C] NM_001184694 MEPE Silent rs1463114 4 88754681 [T/C] NM_001184694,NM_020203,NM_001184695,NM_001184697,NM_001184696 MEPE,MEPE,MEPE,MEPE,MEPE Silent,Silent,Silent,Silent,Silent rs7698623 4 88755828 [T/C] NM_001184694,NM_020203,NM_001184695,NM_001184697,NM_001184696 MEPE,MEPE,MEPE,MEPE,MEPE Silent,Silent,Silent,Silent,Silent rs11097173 4 88755967 [T/C] NM_001184694,NM_020203,NM_001184695,NM_001184697,NM_001184696,NM_001291183 MEPE,MEPE,MEPE,MEPE,MEPE,MEPE Silent,Silent,Silent,Silent,Silent,Silent rs2045836 4 88756245 [T/C] NM_001184694,NM_020203,NM_001184695,NM_001184697,NM_001184696,NM_001291183 MEPE,MEPE,MEPE,MEPE,MEPE,MEPE Silent,Silent,Silent,Silent,Silent,Silent rs2045837 4 88756675 [T/C] NM_001184694,NM_020203,NM_001184695,NM_001184697,NM_001184696,NM_001291183 MEPE,MEPE,MEPE,MEPE,MEPE,MEPE Silent,Silent,Silent,Silent,Silent,Silent rs1381966 4 88756978 [T/C] NM_001184694,NM_020203,NM_001184695,NM_001184697,NM_001184696,NM_001291183 MEPE,MEPE,MEPE,MEPE,MEPE,MEPE Silent,Silent,Silent,Silent,Silent,Silent rs2045838 4 88757008 [A/G] NM_001184694,NM_020203,NM_001184695,NM_001184697,NM_001184696,NM_001291183 MEPE,MEPE,MEPE,MEPE,MEPE,MEPE Silent,Silent,Silent,Silent,Silent,Silent rs17013252 4 88757074 [T/C] NM_001184694,NM_020203,NM_001184695,NM_001184697,NM_001184696,NM_001291183 MEPE,MEPE,MEPE,MEPE,MEPE,MEPE Silent,Silent,Silent,Silent,Silent,Silent rs17712558 4 88757703 [T/G] NM_001184694,NM_020203,NM_001184695,NM_001184697,NM_001184696,NM_001291183 MEPE,MEPE,MEPE,MEPE,MEPE,MEPE Silent,Silent,Silent,Silent,Silent,Silent rs4466013 4 88760413 [A/G] NM_001184694,NM_020203,NM_001184695,NM_001184697,NM_001184696,NM_001291183 MEPE,MEPE,MEPE,MEPE,MEPE,MEPE Silent,Silent,Silent,Silent,Silent,Silent rs13127257 4 88765516 [A/C] NM_001184694,NM_020203,NM_001184695,NM_001184697,NM_001184696,NM_001291183 MEPE,MEPE,MEPE,MEPE,MEPE,MEPE Silent,Silent,Silent,Silent,Silent,Silent rs17013285 4 88767008 [A/G] NM_001184694,NM_020203,NM_001184695,NM_001184697,NM_001184696,NM_001291183 MEPE,MEPE,MEPE,MEPE,MEPE,MEPE EXON Missense_V330I,Missense_V330I,Missense_V217I,Missense_V217I,Missense_V217I,Missense_V361I rs10018094 4 88770890 [A/G] rs1471399 4 88774073 [A/G] rs1471400 4 88774247 [A/G] rs7655902 4 88777743 [T/C] rs931032 4 88778446 [T/C] rs7667813 4 88783177 [T/C] rs1463091 4 88788036 [T/C] rs1026663 4 88789140 [T/C] rs11728139 4 88792438 [A/G] rs17013421 4 88793888 [A/G] rs6815121 4 88795989 [A/G] rs12510860 4 88797100 [A/G] rs4693894 4 88797798 [T/C] rs7672749 4 88798284 [A/G] rs1463104 4 88799710 [T/C] rs13147372 4 88801906 [T/C] rs10222708 4 88804039 [T/C] rs12644436 4 88805208 [A/G] rs10004908 4 88807246 [A/G] rs17013516 4 88808272 [A/G] rs1545745 4 88816732 [T/C] rs4693901 4 88817116 [A/G] rs12651696 4 88821873 [A/G] rs713538 4 88823410 [A/C] rs17013544 4 88823643 [A/C] rs7683960 4 88834454 [A/G] rs716202 4 88836002 [T/C] rs6846509 4 88840386 [T/C] rs16996103 4 88848691 [A/G] rs1477602 4 88849669 [A/G] rs10005067 4 88852643 [T/C] rs1477600 4 88856229 [A/G] rs11723364 4 88859131 [A/C] rs17013569 4 88860764 [A/G] rs4693920 4 88864775 [T/C] rs6532035 4 88867961 [T/C] rs7675985 4 88868506 [A/G] rs6532037 4 88868955 [A/G] rs17013600 4 88878504 [T/C] rs17013609 4 88882095 [A/G] rs4693923 4 88888113 [A/G] rs6833161 4 88889605 [T/C] rs6813526 4 88894235 [T/C] rs2853744 4 88896248 [T/G] rs11730582 4 88896421 [T/C] rs6811536 4 88902405 [T/C] NM_000582,NM_001251830,NM_001040060,NM_001040058,NM_001251829 SPP1,SPP1,SPP1,SPP1,SPP1 Silent,Silent,Silent,Silent,Silent rs4754 4 88902692 [T/C] NM_000582,NM_001251830,NM_001040060,NM_001040058,NM_001251829 SPP1,SPP1,SPP1,SPP1,SPP1 EXON Synonymous_D80D,Synonymous_D107D,Synonymous_D67D,Synonymous_D94D,Synonymous_D53D rs4660 4 88904005 [A/G] NM_000582,NM_001251830,NM_001040060,NM_001040058,NM_001251829 SPP1,SPP1,SPP1,SPP1,SPP1 EXON Missense_R287H,Missense_R314H,Missense_R274H,Missense_R301H,Missense_R260H rs1126772 4 88904186 [A/G] NM_000582,NM_001251830,NM_001040060,NM_001040058,NM_001251829 SPP1,SPP1,SPP1,SPP1,SPP1 EXON Silent,Silent,Silent,Silent,Silent rs10012150 4 88905795 [T/C] rs7685225 4 88906458 [T/C] rs7675246 4 88908998 [A/G] rs2725236 4 88919106 [A/G] rs12500008 4 88924176 [A/C] rs12511728 4 88926020 [T/C] rs6841030 4 88927707 [A/G] rs13110188 4 88928399 [T/C] rs2725233 4 88933584 [T/C] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs2725230 4 88935231 [A/G] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs7660631 4 88936472 [A/G] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs4484262 4 88939000 [A/C] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs10516801 4 88941549 [T/C] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs2725227 4 88944511 [T/C] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs4312723 4 88947869 [A/G] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs2467052 4 88949175 [T/G] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs2725225 4 88952076 [T/C] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs6532045 4 88956521 [A/G] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs17786456 4 88957562 [T/C] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs2725221 4 88959381 [A/G] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs17013735 4 88959745 [A/G] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs7696304 4 88959998 [A/G] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs2725215 4 88961571 [T/C] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs2728108 4 88961736 [A/C] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs4555590 4 88966000 [A/C] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs1801612 4 88967828 [A/G] NM_000297,NR_156488 PKD2,PKD2 EXON Missense_I452V,Silent rs2725211 4 88970375 [T/C] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs2728105 4 88972067 [T/G] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs2728104 4 88973006 [T/C] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs2725207 4 88979529 [A/C] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs2728133 4 88981690 [T/C] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs2725205 4 88985711 [A/G] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs4336187 4 88987916 [A/G] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs2725203 4 88995795 [T/C] NM_000297,NR_156488 PKD2,PKD2 Silent,Silent rs2728121 4 88997102 [T/C] NM_000297,NR_156488 PKD2,PKD2 EXON Silent,Silent rs2725201 4 88999306 [T/G] rs2728125 4 89001893 [A/G] rs17013808 4 89004957 [A/G] rs2725270 4 89007921 [A/C] rs10030206 4 89012091 [T/A] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1448784 4 89012320 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231165 4 89015619 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231164 4 89015857 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231163 4 89015887 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2725267 4 89016175 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9282571 4 89016698 [A/T] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 EXON Synonymous_T567T,Missense_F569I,Missense_F571I,Missense_F571I,Missense_F571I,Missense_F571I,Missense_F571I rs2231162 4 89016782 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231159 4 89017070 [A/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231157 4 89018565 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4148158 4 89018918 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10433946 4 89019837 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6413443 4 89020399 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4148157 4 89020934 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231154 4 89022342 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231153 4 89022362 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs28480245 4 89022860 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4693924 4 89023224 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2725264 4 89026109 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4148156 4 89026242 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2725263 4 89026428 [A/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2622610 4 89027542 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7681519 4 89027840 [G/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231150 4 89028269 [A/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2054576 4 89028775 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2622628 4 89029252 [A/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2622621 4 89030920 [C/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6818074 4 89031814 [T/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2622623 4 89033409 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13120400 4 89033527 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4380486 4 89033771 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3201997 4 89034649 [A/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 EXON Nonsense_E334X,Nonsense_E332X,Nonsense_E334X,Nonsense_E334X,Nonsense_E334X,Nonsense_E334X,Nonsense_E334X rs35427222 4 89035198 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12642930 4 89037056 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6532048 4 89037618 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13143335 4 89039059 [A/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231147 4 89039243 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3116448 4 89039360 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 EXON Missense_S248P,Missense_S248P,Missense_S248P,Missense_S248P,Missense_S248P,Missense_S248P,Missense_S248P rs1871744 4 89039629 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1061018 4 89042853 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 EXON Missense_F208S,Missense_F208S,Missense_F208S,Missense_F208S,Missense_F208S,Missense_F208S,Missense_F208S rs3116439 4 89042912 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 EXON Synonymous_G188G,Synonymous_G188G,Synonymous_G188G,Synonymous_G188G,Synonymous_G188G,Synonymous_G188G,Synonymous_G188G rs3102037 4 89043070 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2725256 4 89050998 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4693925 4 89051917 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3736116 4 89052024 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231143 4 89052199 [T/A] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231141 4 89052377 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231139 4 89052964 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 EXON Synonymous_Y123Y,Synonymous_Y123Y,Synonymous_Y123Y,Synonymous_Y123Y,Synonymous_Y123Y,Synonymous_Y123Y,Synonymous_Y123Y rs3219193 4 89053141 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231138 4 89053718 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17013859 4 89054486 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4148153 4 89056715 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17731631 4 89059819 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12641369 4 89059917 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2725253 4 89060751 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2622617 4 89060777 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4148152 4 89060909 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231137 4 89061114 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 EXON Missense_V12M,Missense_V12M,Missense_V12M,Missense_V12M,Missense_V12M,Missense_V12M,Missense_V12M rs1564481 4 89061265 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10014627 4 89061380 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2725252 4 89061910 [A/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4148150 4 89062189 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4148149 4 89062285 [T/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13137622 4 89062513 [T/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2046134 4 89063363 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2725250 4 89063985 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3109823 4 89064602 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17013881 4 89065076 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2622627 4 89065353 [A/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6857600 4 89066075 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2622626 4 89066715 [A/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6532049 4 89067526 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2725246 4 89068498 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2622624 4 89069406 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2725242 4 89069527 [T/A] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10015296 4 89071025 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6843854 4 89071104 [A/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6843542 4 89071169 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13113161 4 89071602 [T/G] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7692080 4 89072018 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2622604 4 89078924 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2622605 4 89079386 [T/C] NM_001257386,NM_001348987,NM_004827,NM_001348985,NM_001348986,NM_001348989,NM_001348988 ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2,ABCG2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2231134 4 89080351 [C/G] NM_001257386,NM_001348985,NM_001348989 ABCG2,ABCG2,ABCG2 Silent,Silent,Silent rs3114019 4 89081441 [T/C] NM_001257386,NM_001348985 ABCG2,ABCG2 Silent,Silent rs3114020 4 89083666 [T/C] NM_001257386,NM_001348985 ABCG2,ABCG2 Silent,Silent rs10011796 4 89090877 [T/C] NM_001257386,NM_001348985 ABCG2,ABCG2 Silent,Silent rs2622629 4 89094064 [T/C] NM_001257386,NM_001348985 ABCG2,ABCG2 Silent,Silent rs7658584 4 89096641 [A/G] NM_001257386,NM_001348985 ABCG2,ABCG2 Silent,Silent rs2127863 4 89111468 [T/C] NM_001257386,NM_001348985 ABCG2,ABCG2 Silent,Silent rs10856870 4 89119659 [T/C] NM_001257386,NM_001348985 ABCG2,ABCG2 Silent,Silent rs11723264 4 89129484 [A/G] NM_001257386,NM_001348985 ABCG2,ABCG2 Silent,Silent rs4693933 4 89139002 [T/C] NM_001257386,NM_001348985 ABCG2,ABCG2 Silent,Silent rs4693935 4 89139275 [A/G] NM_001257386,NM_001348985 ABCG2,ABCG2 Silent,Silent rs2904185 4 89139832 [T/C] NM_001257386,NM_001348985 ABCG2,ABCG2 Silent,Silent rs1114568 4 89159819 [A/G] rs13120819 4 89160677 [A/G] rs6532059 4 89163923 [T/C] rs6532061 4 89165613 [T/C] rs11932727 4 89165737 [T/C] rs1351441 4 89167407 [T/C] rs11729997 4 89171059 [A/C] rs11733577 4 89174193 [T/C] rs12642881 4 89183194 [T/G] NM_152542 PPM1K EXON Silent rs7682161 4 89191346 [T/C] NM_152542 PPM1K Silent rs7656367 4 89196821 [A/G] NM_152542 PPM1K Silent rs7661312 4 89201007 [T/G] NM_152542 PPM1K Silent rs881561 4 89203042 [A/G] NM_152542 PPM1K Silent rs17013978 4 89203197 [T/C] NM_152542 PPM1K Silent rs17732955 4 89204093 [T/C] NM_152542 PPM1K Silent rs4423843 4 89206756 [A/G] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 Silent,Silent,Silent rs958325 4 89209681 [T/C] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 Silent,Silent,Silent rs34813495 4 89213077 [A/G] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 Silent,Silent,Silent rs12641788 4 89222164 [T/C] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 Silent,Silent,Silent rs1440581 4 89226422 [T/C] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 Silent,Silent,Silent rs17013995 4 89227094 [A/G] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 Silent,Silent,Silent rs17789621 4 89227121 [T/C] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 Silent,Silent,Silent rs6841731 4 89228928 [A/G] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 Silent,Silent,Silent rs893970 4 89236735 [T/C] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 Silent,Silent,Silent rs1545207 4 89239492 [A/G] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 Silent,Silent,Silent rs10022462 4 89243818 [T/C] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 Silent,Silent,Silent rs2869929 4 89244007 [T/C] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 Silent,Silent,Silent rs4693211 4 89249061 [T/C] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 Silent,Silent,Silent rs10001661 4 89249372 [A/G] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 Silent,Silent,Silent rs12512051 4 89252068 [T/C] NR_134237,NR_134238,NR_134236 LOC105369192,LOC105369192,LOC105369192 EXON Silent,Silent,Silent rs17014031 4 89252659 [T/C] NR_134238 LOC105369192 Silent rs7657298 4 89253079 [T/C] NR_134238 LOC105369192 Silent rs17014050 4 89258623 [T/C] NR_134238 LOC105369192 Silent rs2869928 4 89261908 [T/C] NR_134238 LOC105369192 Silent rs10023703 4 89262148 [A/C] NR_134238 LOC105369192 Silent rs4693953 4 89270121 [T/C] rs4693954 4 89277494 [A/C] rs9968290 4 89281683 [T/G] rs6829542 4 89282107 [A/G] rs4693212 4 89283496 [T/C] rs4693957 4 89287096 [A/G] rs12651141 4 89287709 [A/G] rs10016511 4 89293265 [T/C] rs10029067 4 89293297 [A/G] rs28694742 4 89299174 [A/G] rs11097187 4 89302101 [A/G] NM_001165136,NM_017912 HERC6,HERC6 Silent,Silent rs7660771 4 89305062 [A/G] NM_001165136,NM_017912 HERC6,HERC6 Silent,Silent rs7677237 4 89306659 [T/C] NM_001165136,NM_017912 HERC6,HERC6 EXON Missense_M123T,Missense_M123T rs12510688 4 89311962 [T/C] NM_001165136,NM_017912 HERC6,HERC6 EXON Missense_C199R,Missense_C199R rs17014114 4 89314310 [T/C] NM_001165136,NM_017912 HERC6,HERC6 Silent,Silent rs17014115 4 89316229 [A/G] NM_001165136,NM_017912 HERC6,HERC6 Silent,Silent rs7662660 4 89320406 [A/G] NM_001165136,NM_017912 HERC6,HERC6 Silent,Silent rs12642398 4 89323214 [T/C] NM_001165136,NM_017912 HERC6,HERC6 Silent,Silent rs17014132 4 89329577 [T/C] NM_001165136,NM_017912 HERC6,HERC6 Silent,Silent rs6850385 4 89335667 [T/C] NM_001165136,NM_017912 HERC6,HERC6 Silent,Silent rs7670637 4 89342976 [T/C] NM_001165136,NM_017912 HERC6,HERC6 Silent,Silent rs6532068 4 89345760 [T/C] NM_001165136,NM_017912 HERC6,HERC6 EXON Silent,Missense_T614I rs10006830 4 89355103 [T/C] NM_001165136,NM_017912 HERC6,HERC6 Silent,Silent rs10516808 4 89383662 [A/G] NM_016323 HERC5 Silent rs17014143 4 89385126 [A/G] NM_016323 HERC5 EXON Missense_A301T rs12505811 4 89389157 [A/G] NM_016323 HERC5 Silent rs4585264 4 89389640 [A/C] NM_016323 HERC5 Silent rs6816627 4 89392435 [A/C] NM_016323 HERC5 Silent rs7663568 4 89408602 [T/C] NM_016323 HERC5 Silent rs11722508 4 89417500 [A/C] NM_016323 HERC5 Silent rs10516809 4 89421086 [A/G] NM_016323 HERC5 EXON Synonymous_Q818Q rs7665582 4 89433700 [T/C] rs28476740 4 89436231 [T/C] rs2717533 4 89441779 [A/G] rs4693959 4 89445906 [T/G] NR_134662,NR_134663 LOC101929134,LOC101929134 Silent,Silent rs17014162 4 89447064 [T/C] rs6823968 4 89448232 [T/G] rs3846281 4 89451509 [A/C] rs10031689 4 89452479 [T/C] rs2869665 4 89453522 [A/G] rs10516810 4 89454661 [A/C] rs7435410 4 89456219 [A/G] rs17014179 4 89457478 [T/C] rs11736472 4 89458051 [A/G] rs17014220 4 89477899 [A/G] rs6850944 4 89482021 [T/C] rs7671998 4 89494828 [T/C] rs10084787 4 89512853 [A/G] rs6857847 4 89514572 [A/G] NM_014606,NM_001318505,NM_001271602 HERC3,HERC3,HERC3 Silent,Silent,Silent rs3822084 4 89522699 [T/G] NM_014606,NM_001318505,NM_001271602 HERC3,HERC3,HERC3 Silent,Silent,Silent rs17014252 4 89525053 [T/C] NM_014606,NM_001318505,NM_001271602 HERC3,HERC3,HERC3 Silent,Silent,Silent rs17014254 4 89526143 [T/C] NM_014606,NM_001318505,NM_001271602 HERC3,HERC3,HERC3 Silent,Silent,Silent rs17799056 4 89527323 [A/G] NM_014606,NM_001318505,NM_001271602 HERC3,HERC3,HERC3 Silent,Silent,Silent rs2924942 4 89532682 [A/G] NM_014606,NM_001318505,NM_001271602 HERC3,HERC3,HERC3 Silent,Silent,Silent rs11935902 4 89539581 [A/G] NM_014606,NM_001318505,NM_001271602 HERC3,HERC3,HERC3 Silent,Silent,Silent rs10028621 4 89540209 [T/C] NM_014606,NM_001318505,NM_001271602 HERC3,HERC3,HERC3 Silent,Silent,Silent rs2869663 4 89542281 [T/C] NM_014606,NM_001318505,NM_001271602 HERC3,HERC3,HERC3 Silent,Silent,Silent rs2972023 4 89555107 [A/G] NM_014606,NM_001318505,NM_001271602 HERC3,HERC3,HERC3 Silent,Silent,Silent rs2869664 4 89562091 [T/G] NM_014606,NM_001318505,NM_001271602 HERC3,HERC3,HERC3 Silent,Silent,Silent rs3017925 4 89567767 [A/G] NM_014606,NM_001318505,NM_001271602 HERC3,HERC3,HERC3 Silent,Silent,Silent rs2924939 4 89584883 [A/G] NM_014606,NM_001271602 HERC3,HERC3 Silent,Silent rs17014374 4 89585781 [T/C] NM_014606,NM_001271602 HERC3,HERC3 Silent,Silent rs3737488 4 89607905 [A/G] NM_014606,NM_001271602 HERC3,HERC3 EXON Synonymous_L842L,Synonymous_L724L rs1020593 4 89612444 [T/C] NM_014606,NM_001271602 HERC3,HERC3 Silent,Silent rs2924358 4 89615729 [A/C] NM_014606,NM_001271602 HERC3,HERC3 Silent,Silent rs2602122 4 89617441 [A/C] NM_014606,NM_001271602,NM_153757 HERC3,HERC3,NAP1L5 EXON Silent,Silent,Silent rs2924924 4 89622904 [T/G] NM_014606,NM_001271602 HERC3,HERC3 Silent,Silent rs1063143 4 89629000 [A/G] NM_014606,NM_001271602 HERC3,HERC3 EXON Silent,Silent rs2602117 4 89629066 [T/C] NM_014606,NM_001271602 HERC3,HERC3 EXON Silent,Silent rs6829163 4 89632184 [T/C] NR_002806 FAM13A-AS1 Silent rs2860408 4 89639032 [A/G] NR_002806 FAM13A-AS1 Silent rs2924936 4 89641514 [A/G] NR_002806 FAM13A-AS1 Silent rs2924941 4 89644197 [T/C] NR_002806 FAM13A-AS1 Silent rs2860500 4 89647070 [T/C] NR_002806 FAM13A-AS1 Silent rs13130 4 89648845 [A/G] NR_002806,NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A-AS1,FAM13A,FAM13A,FAM13A,FAM13A,FAM13A EXON Silent,Silent,Silent,Silent,Silent,Silent rs3017895 4 89649491 [A/G] NR_002806,NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A-AS1,FAM13A,FAM13A,FAM13A,FAM13A,FAM13A EXON Silent,Silent,Silent,Silent,Silent,Silent rs9224 4 89649659 [A/G] NR_002806,NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A-AS1,FAM13A,FAM13A,FAM13A,FAM13A,FAM13A EXON Silent,Silent,Silent,Silent,Silent,Silent rs1801915 4 89653257 [A/G] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A EXON Synonymous_D913D,Synonymous_D559D,Synonymous_D573D,Synonymous_D587D,Synonymous_D559D rs3775391 4 89665193 [A/G] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs17014483 4 89667591 [T/C] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs7657817 4 89668859 [T/C] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A EXON Missense_V769I,Missense_V415I,Missense_V429I,Missense_V443I,Missense_V443I rs11944668 4 89669852 [A/C] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs3756050 4 89670155 [T/C] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A EXON Synonymous_P703P,Synonymous_P349P,Synonymous_P363P,Synonymous_P377P,Synonymous_P377P rs7662156 4 89672805 [T/C] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs1965869 4 89677537 [T/C] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs17014513 4 89684640 [T/C] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs3816453 4 89693098 [T/C] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs10017416 4 89703883 [A/G] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs9991328 4 89713121 [T/C] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs7680994 4 89717990 [A/G] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs17014580 4 89724236 [T/C] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs10516821 4 89727979 [T/C] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs3775380 4 89739808 [A/G] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs2869950 4 89742764 [T/C] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs3775373 4 89743821 [T/G] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A Silent,Silent,Silent,Silent,Silent rs2305934 4 89744242 [T/C] NM_014883,NM_001265580,NM_001265578,NM_001015045,NM_001265579 FAM13A,FAM13A,FAM13A,FAM13A,FAM13A EXON Silent,Silent,Silent,Silent,Silent rs1379935 4 89751291 [A/G] NM_014883 FAM13A Silent rs7660000 4 89751858 [T/C] NM_014883 FAM13A Silent rs7698655 4 89756076 [A/G] NM_014883 FAM13A Silent rs11097200 4 89761563 [T/C] NM_014883 FAM13A Silent rs10461165 4 89770583 [A/G] NM_014883 FAM13A Silent rs7680970 4 89772301 [A/C] NM_014883 FAM13A EXON Missense_A293S rs11735482 4 89776246 [T/C] NM_014883 FAM13A Silent rs6830970 4 89777081 [A/G] NM_014883 FAM13A Silent rs1979290 4 89789478 [T/G] NM_014883 FAM13A Silent rs10049947 4 89790593 [T/C] NM_014883 FAM13A Silent rs10516823 4 89797638 [A/G] NM_014883 FAM13A Silent rs17816002 4 89798954 [A/C] NM_014883 FAM13A Silent rs13131811 4 89799575 [A/G] NM_014883 FAM13A Silent rs2609255 4 89811195 [T/G] NM_014883 FAM13A Silent rs2609264 4 89828080 [T/C] NM_014883 FAM13A Silent rs13109149 4 89831335 [T/C] NM_014883 FAM13A Silent rs10019681 4 89832532 [T/C] NM_014883 FAM13A Silent rs1458555 4 89835017 [T/C] NM_014883 FAM13A Silent rs4693976 4 89839840 [T/C] NM_014883 FAM13A Silent rs2704588 4 89849772 [T/C] NM_014883 FAM13A Silent rs1458562 4 89853598 [T/C] NM_014883 FAM13A Silent rs2869966 4 89869078 [T/C] NM_014883 FAM13A Silent rs2869967 4 89869332 [T/C] NM_014883 FAM13A Silent rs2464526 4 89879663 [A/G] NM_014883 FAM13A Silent rs7671167 4 89883979 [T/C] NM_014883 FAM13A Silent rs1903003 4 89886297 [T/C] NM_014883 FAM13A Silent rs1458558 4 89887620 [T/C] NM_014883 FAM13A Silent rs2085601 4 89895944 [A/C] NM_014883 FAM13A Silent rs6838424 4 89896036 [A/G] NM_014883 FAM13A Silent rs17817631 4 89897373 [T/C] NM_014883 FAM13A Silent rs16996144 4 89897522 [A/G] NM_014883 FAM13A Silent rs11737182 4 89898476 [T/C] NM_014883 FAM13A Silent rs10007590 4 89917135 [A/G] NM_014883 FAM13A Silent rs9307061 4 89918629 [T/C] NM_014883 FAM13A Silent rs10516825 4 89920082 [A/C] NM_014883 FAM13A Silent rs1921684 4 89922143 [T/C] NM_014883 FAM13A Silent rs6849143 4 89928489 [T/C] NM_014883 FAM13A Silent rs6824116 4 89928843 [T/C] NM_014883 FAM13A Silent rs17014898 4 89930134 [A/C] NM_014883 FAM13A Silent rs1398942 4 89930392 [A/G] NM_014883 FAM13A Silent rs12505696 4 89931070 [T/C] NM_014883 FAM13A Silent rs1795734 4 89933630 [A/C] NM_014883 FAM13A Silent rs1708661 4 89938564 [T/C] NM_014883 FAM13A Silent rs6822256 4 89940992 [A/G] NM_014883 FAM13A Silent rs9993181 4 89945459 [T/C] NM_014883 FAM13A Silent rs1343921 4 89947462 [T/C] NM_014883 FAM13A Silent rs13140085 4 89954027 [T/C] NM_014883 FAM13A Silent rs1588730 4 89955623 [A/G] NM_014883 FAM13A Silent rs1533291 4 89964456 [T/C] NM_014883 FAM13A Silent rs1708676 4 89974554 [A/C] NM_014883 FAM13A Silent rs6826407 4 89975033 [T/C] NM_014883 FAM13A Silent rs1795731 4 89976882 [T/C] NM_014883 FAM13A Silent rs11097210 4 89978281 [A/G] NM_014883 FAM13A EXON Silent rs6845151 4 89992190 [T/C] rs9790655 4 89992347 [T/C] rs13148714 4 90002785 [A/G] rs12649385 4 90010941 [T/C] rs6825998 4 90011642 [T/C] rs13144759 4 90017784 [A/G] rs4627822 4 90024739 [A/G] rs7440590 4 90028412 [T/C] rs17015025 4 90034030 [A/G] NM_145715 TIGD2 EXON Silent rs2280099 4 90035549 [A/G] NM_145715 TIGD2 EXON Missense_H475R rs12645173 4 90036099 [A/G] rs4367140 4 90044292 [A/C] rs13138280 4 90046848 [A/G] rs17821540 4 90049495 [T/C] rs7687207 4 90049968 [A/G] rs1398944 4 90057814 [A/G] rs6828137 4 90059434 [T/G] rs7690336 4 90062409 [A/G] rs4552429 4 90067301 [A/G] rs756227 4 90069964 [T/C] rs756345 4 90073214 [A/G] rs6532123 4 90091547 [A/G] rs17771380 4 90099188 [T/C] rs636446 4 90100155 [T/C] rs6832231 4 90102682 [A/G] rs9990512 4 90107063 [A/C] rs2116325 4 90115197 [T/C] rs524907 4 90115680 [T/G] rs11734085 4 90116188 [A/G] rs13353765 4 90116432 [T/C] rs6821473 4 90123667 [T/C] rs695053 4 90124654 [A/G] rs7688911 4 90125419 [A/C] rs678701 4 90126051 [T/C] rs679672 4 90126331 [A/G] rs7674810 4 90126898 [T/C] rs7696471 4 90126909 [T/C] rs499411 4 90133795 [T/C] rs518156 4 90137336 [A/C] rs656063 4 90137884 [A/C] rs17015190 4 90138063 [A/G] rs6850331 4 90142016 [T/C] rs9307064 4 90146649 [A/G] rs17773361 4 90149589 [A/C] rs4693223 4 90150552 [A/G] rs10023728 4 90152353 [A/G] rs1978673 4 90152565 [T/C] rs6847228 4 90155694 [T/C] rs7660707 4 90161863 [T/C] rs891674 4 90166159 [A/G] NM_198281 GPRIN3 EXON Silent rs6532146 4 90166778 [A/C] NM_198281 GPRIN3 EXON Silent rs6532148 4 90166921 [A/G] NM_198281 GPRIN3 EXON Silent rs10516830 4 90167445 [T/G] NM_198281 GPRIN3 EXON Silent rs1431548 4 90168572 [T/C] NM_198281 GPRIN3 EXON Silent rs7672015 4 90168825 [T/C] NM_198281 GPRIN3 EXON Silent rs7653897 4 90169925 [A/G] NM_198281 GPRIN3 EXON Missense_V446A rs11734353 4 90171147 [C/G] NM_198281 GPRIN3 EXON Missense_L39V rs2298756 4 90171503 [T/C] NM_198281 GPRIN3 Silent rs6532149 4 90180437 [A/C] NM_198281 GPRIN3 Silent rs6532151 4 90188353 [T/C] NM_198281 GPRIN3 Silent rs6830724 4 90193727 [T/C] NM_198281 GPRIN3 Silent rs4399946 4 90194997 [T/C] NM_198281 GPRIN3 Silent rs1560489 4 90198463 [T/C] NM_198281 GPRIN3 Silent rs4557230 4 90202027 [A/G] NM_198281 GPRIN3 Silent rs11946523 4 90203035 [A/C] NM_198281 GPRIN3 Silent rs12640416 4 90205253 [A/C] NM_198281 GPRIN3 Silent rs17015332 4 90207602 [T/C] NM_198281 GPRIN3 Silent rs937719 4 90209723 [A/G] NM_198281 GPRIN3 Silent rs1079070 4 90211918 [T/C] NM_198281 GPRIN3 Silent rs1019875 4 90214108 [T/C] NM_198281 GPRIN3 Silent rs7687888 4 90216747 [T/G] NM_198281 GPRIN3 Silent rs1560488 4 90225835 [T/C] NM_198281 GPRIN3 Silent rs7653939 4 90227469 [A/G] NM_198281 GPRIN3 Silent rs17015404 4 90228238 [T/C] NM_198281 GPRIN3 Silent rs4693992 4 90233839 [A/G] rs1431559 4 90235488 [A/G] rs10015406 4 90238073 [A/G] rs13104039 4 90241029 [T/G] rs10027938 4 90242059 [A/G] rs4106153 4 90244476 [A/C] rs1463908 4 90255167 [A/G] rs1875863 4 90256211 [T/C] rs17015445 4 90259075 [A/G] rs17015458 4 90271894 [A/G] rs17015461 4 90271977 [A/G] rs10516833 4 90272120 [A/G] rs12511565 4 90277638 [A/G] rs6846715 4 90280688 [A/G] rs6821767 4 90285544 [T/G] rs1504484 4 90295681 [A/G] rs6827974 4 90306233 [A/G] rs12650758 4 90309312 [T/C] rs1105137 4 90310346 [T/C] rs1910679 4 90310693 [A/G] rs10018371 4 90334129 [A/C] rs10516836 4 90337993 [A/G] rs12643268 4 90371779 [A/G] rs17778445 4 90371934 [A/G] rs772492 4 90372566 [T/C] rs13434975 4 90372847 [A/C] rs772494 4 90373071 [T/C] rs772496 4 90373435 [A/G] rs9990906 4 90374397 [T/G] rs772501 4 90375951 [T/C] rs7691267 4 90384672 [T/C] rs2172895 4 90385574 [T/G] rs976595 4 90388994 [A/G] rs1495553 4 90389965 [T/C] rs9998962 4 90395266 [A/G] rs12644111 4 90395499 [T/C] rs2132281 4 90404263 [A/G] rs2172894 4 90404465 [T/C] rs17015658 4 90408036 [A/C] rs12648284 4 90410551 [A/G] rs17174961 4 90418192 [A/G] rs1908556 4 90421700 [A/G] rs10008041 4 90422209 [T/C] rs9631722 4 90425319 [A/G] rs6847082 4 90426323 [T/C] rs17015705 4 90426646 [A/G] rs1495552 4 90429040 [T/G] rs903600 4 90430695 [T/C] rs13146919 4 90431418 [T/C] rs17175612 4 90432177 [T/C] rs6840873 4 90432746 [A/G] rs6854472 4 90434672 [T/G] rs729686 4 90435011 [A/G] rs17015738 4 90439694 [T/C] rs11097225 4 90441824 [T/G] rs4694010 4 90450579 [T/C] rs1495555 4 90455728 [A/G] rs1495556 4 90458283 [T/C] rs17015756 4 90458351 [A/G] rs4147250 4 90461313 [T/C] rs17780881 4 90478149 [T/C] rs17015822 4 90481673 [T/C] rs1826739 4 90484613 [T/G] rs1156115 4 90492766 [T/C] rs1495557 4 90494272 [A/G] rs2870006 4 90495946 [A/G] rs1473533 4 90516679 [A/G] rs6852411 4 90522480 [A/C] rs6850389 4 90527344 [A/G] rs17015895 4 90527778 [T/C] rs10000875 4 90538108 [T/C] rs10016053 4 90551351 [A/G] rs1430961 4 90552920 [A/G] rs12513009 4 90555520 [A/G] rs11932021 4 90565218 [T/C] rs3733449 4 90572322 [T/C] rs9992727 4 90584840 [T/C] rs10213062 4 90600620 [T/C] rs13108925 4 90602795 [T/C] rs12644119 4 90603419 [A/C] rs17015992 4 90604557 [A/G] rs3857047 4 90606518 [T/G] rs3910106 4 90610135 [T/A] rs17016018 4 90614899 [T/G] rs17286290 4 90618264 [T/G] rs3906628 4 90618526 [A/G] rs3857050 4 90625419 [T/C] rs356174 4 90630901 [T/G] rs356220 4 90641340 [T/C] rs8180209 4 90644454 [A/G] rs356168 4 90674431 [A/G] NM_007308,NM_001146054,NM_000345,NM_001146055 SNCA,SNCA,SNCA,SNCA Silent,Silent,Silent,Silent rs2736990 4 90678541 [A/G] NM_007308,NM_001146054,NM_000345,NM_001146055 SNCA,SNCA,SNCA,SNCA Silent,Silent,Silent,Silent rs3796661 4 90687507 [T/C] NM_007308,NM_001146054,NM_000345,NM_001146055 SNCA,SNCA,SNCA,SNCA Silent,Silent,Silent,Silent rs3775439 4 90709741 [A/G] NM_007308,NM_001146054,NM_000345,NM_001146055 SNCA,SNCA,SNCA,SNCA Silent,Silent,Silent,Silent rs10014396 4 90712629 [T/C] NM_007308,NM_001146054,NM_000345,NM_001146055 SNCA,SNCA,SNCA,SNCA Silent,Silent,Silent,Silent rs12502363 4 90713064 [A/G] NM_007308,NM_001146054,NM_000345,NM_001146055 SNCA,SNCA,SNCA,SNCA Silent,Silent,Silent,Silent rs3775442 4 90715231 [T/C] NM_007308,NM_001146054,NM_000345,NM_001146055 SNCA,SNCA,SNCA,SNCA Silent,Silent,Silent,Silent rs3889917 4 90716852 [T/C] NM_007308,NM_001146054,NM_000345,NM_001146055 SNCA,SNCA,SNCA,SNCA Silent,Silent,Silent,Silent rs1866995 4 90731709 [A/G] NM_007308,NM_001146054,NM_000345,NM_001146055 SNCA,SNCA,SNCA,SNCA Silent,Silent,Silent,Silent rs1442144 4 90736113 [T/C] NM_007308,NM_001146054,NM_000345,NM_001146055 SNCA,SNCA,SNCA,SNCA Silent,Silent,Silent,Silent rs3822095 4 90736517 [T/C] NM_007308,NM_001146054,NM_000345,NM_001146055 SNCA,SNCA,SNCA,SNCA Silent,Silent,Silent,Silent rs1812923 4 90739539 [A/C] NM_007308,NM_001146054,NM_000345,NM_001146055 SNCA,SNCA,SNCA,SNCA Silent,Silent,Silent,Silent rs10005233 4 90743331 [T/C] NM_007308,NM_001146054,NM_000345,NM_001146055 SNCA,SNCA,SNCA,SNCA Silent,Silent,Silent,Silent rs11097238 4 90746709 [T/C] NM_007308,NM_001146054,NM_000345,NM_001146055 SNCA,SNCA,SNCA,SNCA Silent,Silent,Silent,Silent rs2301134 4 90758945 [A/G] NM_001146055,NR_045481 SNCA,SNCA-AS1 Silent,Silent rs1023777 4 90761412 [T/C] NR_045481 SNCA-AS1 Silent rs12331318 4 90770255 [T/C] rs17016279 4 90770408 [A/G] rs10516848 4 90775212 [A/G] rs2737026 4 90779823 [A/G] rs6532194 4 90780902 [T/C] rs6532196 4 90781261 [A/G] rs10516849 4 90789539 [A/G] rs11097239 4 90795804 [A/C] rs6532197 4 90797301 [A/G] rs1899389 4 90802998 [A/G] rs1442140 4 90816023 [A/G] rs1442138 4 90816294 [A/G] NM_007351 MMRN1 EXON Missense_T58A rs1442137 4 90818857 [T/C] NM_007351 MMRN1 Silent rs3775464 4 90826760 [A/G] NM_007351 MMRN1 Silent rs3775465 4 90827466 [A/C] NM_007351 MMRN1 Silent rs9307077 4 90833372 [A/G] NM_007351 MMRN1 Silent rs10011790 4 90833421 [A/G] NM_007351 MMRN1 Silent rs10516850 4 90837127 [A/G] NM_007351 MMRN1 Silent rs3775478 4 90842840 [A/G] NM_007351 MMRN1 Silent rs2241884 4 90844848 [A/G] NM_007351 MMRN1 Silent rs10030931 4 90862372 [A/G] NM_007351 MMRN1 Silent rs3775483 4 90870359 [A/G] NM_007351 MMRN1 Silent rs1479429 4 90871662 [T/C] NM_007351 MMRN1 Silent rs13109927 4 90875910 [A/G] rs7667606 4 90879406 [A/G] rs12233759 4 90880403 [A/G] rs11939062 4 90882154 [A/C] rs11931138 4 90883047 [A/C] rs13107488 4 90895017 [A/G] rs6532210 4 90910930 [A/G] rs10516854 4 90916437 [T/C] rs12507661 4 90923554 [T/C] rs13113259 4 90928959 [A/G] rs11728457 4 90938575 [A/G] rs6812321 4 90942824 [A/G] rs17808648 4 90947793 [T/G] rs17016459 4 90958046 [T/C] rs12510783 4 90962137 [T/C] rs13141923 4 90962886 [A/G] rs724454 4 90963446 [A/C] rs1443797 4 90968156 [A/G] rs11929845 4 90969565 [A/G] rs722937 4 90971745 [T/G] rs722936 4 90971800 [A/C] rs13114320 4 90976413 [A/G] rs894803 4 90993172 [A/C] rs2197291 4 91000334 [T/C] rs34001515 4 91025850 [T/G] rs7674520 4 91033300 [T/C] rs12644131 4 91046719 [T/C] rs6837278 4 91069888 [A/G] NM_001145065 CCSER1 Silent rs10461168 4 91123665 [T/G] NM_001145065 CCSER1 Silent rs13109951 4 91123874 [A/G] NM_001145065 CCSER1 Silent rs17008807 4 91154964 [T/G] NM_001145065 CCSER1 Silent rs4356886 4 91156917 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10015971 4 91158914 [T/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17016696 4 91164874 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17016697 4 91165346 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs6832140 4 91172438 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10013360 4 91175600 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs11945084 4 91183746 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10031810 4 91185206 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs7676938 4 91190319 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs1350855 4 91194806 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs11946195 4 91199217 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs2126281 4 91202358 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs11937852 4 91203145 [T/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs13147804 4 91210048 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs9991550 4 91211087 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10516867 4 91212092 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs1037926 4 91227681 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs12647859 4 91230579 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 EXON Missense_G382S,Missense_G382S rs2870246 4 91234498 [A/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17016737 4 91246853 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs11723677 4 91247973 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10015182 4 91253355 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs11941084 4 91254663 [A/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs7693233 4 91254945 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17016824 4 91267470 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs12642077 4 91269591 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs8180269 4 91271176 [T/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs4693236 4 91280571 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17016910 4 91287204 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17016912 4 91287263 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs6842950 4 91289294 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs1903577 4 91296454 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10026110 4 91297445 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs7688033 4 91301321 [T/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs2169398 4 91307525 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs6834254 4 91319038 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs11942690 4 91336936 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs12645541 4 91340811 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs11930977 4 91342005 [T/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10027018 4 91350425 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10022049 4 91366628 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10002613 4 91367607 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs6843585 4 91371416 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs1581062 4 91376378 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs7676707 4 91406782 [T/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17017061 4 91419040 [T/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs7661714 4 91420358 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs11097253 4 91428124 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs6838438 4 91429013 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs12643810 4 91433794 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs2036153 4 91460581 [A/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17017104 4 91464162 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs6532233 4 91465389 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs6849123 4 91465511 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs6822624 4 91469221 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10010423 4 91475787 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs6845935 4 91481271 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs9996173 4 91490629 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs2008600 4 91500284 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10003689 4 91501578 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs1510795 4 91501614 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17017214 4 91504238 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs2048398 4 91514884 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10008997 4 91515710 [T/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10031325 4 91516040 [A/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17017247 4 91516422 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17017255 4 91524285 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs7687903 4 91526531 [T/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs9884326 4 91532461 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17240838 4 91533617 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17017280 4 91534943 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17017282 4 91535070 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs7697772 4 91546159 [T/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs9790562 4 91546380 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17017323 4 91551390 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs7672803 4 91566875 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs950127 4 91567112 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs2132834 4 91567979 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs12505502 4 91568023 [T/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10014992 4 91568501 [T/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17017347 4 91573596 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs2088386 4 91574795 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs10022603 4 91574914 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs1399409 4 91576994 [A/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs1567929 4 91591467 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs13113267 4 91606389 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs6856591 4 91607363 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17017439 4 91630043 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs13150060 4 91632410 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs7660162 4 91633300 [A/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17017443 4 91636530 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17183896 4 91638789 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17017488 4 91653148 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs1355993 4 91661745 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs1399419 4 91664577 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs1399420 4 91664865 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs1114878 4 91667562 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs17244178 4 91671650 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs6532239 4 91674460 [A/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs6833239 4 91676401 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs1514742 4 91680245 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs1454329 4 91685949 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs7667003 4 91687322 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs7693519 4 91691313 [T/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs7685883 4 91695730 [A/G] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs11727861 4 91700548 [T/C] NM_001145065,NM_207491 CCSER1,CCSER1 Silent,Silent rs1869539 4 91709484 [A/G] NM_001145065 CCSER1 Silent rs11097264 4 91711665 [A/G] NM_001145065 CCSER1 Silent rs11932857 4 91715008 [A/G] NM_001145065 CCSER1 Silent rs17246676 4 91722598 [T/C] NM_001145065 CCSER1 Silent rs10856879 4 91725803 [T/C] NM_001145065 CCSER1 Silent rs7678915 4 91729462 [A/G] NM_001145065 CCSER1 Silent rs17187375 4 91732390 [A/G] NM_001145065 CCSER1 Silent rs17017652 4 91737500 [A/C] NM_001145065 CCSER1 Silent rs10516879 4 91740550 [T/C] NM_001145065 CCSER1 Silent rs17017704 4 91748644 [T/C] NM_001145065 CCSER1 Silent rs10021524 4 91762984 [A/G] NM_001145065 CCSER1 Silent rs11725878 4 91764098 [A/G] NM_001145065 CCSER1 Silent rs6822939 4 91764932 [A/G] NM_001145065 CCSER1 Silent rs9998288 4 91767861 [A/G] NM_001145065 CCSER1 Silent rs10010346 4 91768115 [T/C] NM_001145065 CCSER1 Silent rs7662582 4 91769382 [A/C] NM_001145065 CCSER1 Silent rs17195440 4 91772546 [A/G] NM_001145065 CCSER1 Silent rs11936158 4 91775333 [T/C] NM_001145065 CCSER1 Silent rs17248761 4 91775468 [A/G] NM_001145065 CCSER1 Silent rs12642829 4 91786842 [A/G] NM_001145065 CCSER1 Silent rs17196007 4 91787375 [A/G] NM_001145065 CCSER1 Silent rs13143215 4 91788611 [T/G] NM_001145065 CCSER1 Silent rs4693247 4 91788661 [T/G] NM_001145065 CCSER1 Silent rs10004104 4 91790439 [T/C] NM_001145065 CCSER1 Silent rs9994175 4 91806782 [A/G] NM_001145065 CCSER1 Silent rs11946311 4 91816783 [A/G] NM_001145065 CCSER1 Silent rs6828263 4 91819988 [T/C] NM_001145065 CCSER1 Silent rs6840937 4 91821398 [T/C] NM_001145065 CCSER1 Silent rs1377917 4 91823910 [A/G] NM_001145065 CCSER1 Silent rs1037910 4 91825652 [A/G] NM_001145065 CCSER1 Silent rs1454339 4 91827278 [T/C] NM_001145065 CCSER1 Silent rs17017809 4 91827528 [A/G] NM_001145065 CCSER1 Silent rs11097273 4 91828373 [A/C] NM_001145065 CCSER1 Silent rs7676836 4 91829443 [A/G] NM_001145065 CCSER1 Silent rs7683238 4 91830496 [T/C] NM_001145065 CCSER1 Silent rs11721809 4 91830539 [T/G] NM_001145065 CCSER1 Silent rs9994801 4 91831513 [A/G] NM_001145065 CCSER1 Silent rs10012191 4 91847796 [T/C] NM_001145065 CCSER1 Silent rs11097280 4 91860898 [A/G] NM_001145065 CCSER1 Silent rs2870278 4 91862940 [A/G] NM_001145065 CCSER1 Silent rs10433957 4 91866171 [T/C] NM_001145065 CCSER1 Silent rs7679165 4 91868624 [T/C] NM_001145065 CCSER1 Silent rs34473363 4 91869258 [T/G] NM_001145065 CCSER1 Silent rs11097282 4 91871784 [A/G] NM_001145065 CCSER1 Silent rs1947442 4 91872431 [A/G] NM_001145065 CCSER1 Silent rs11097283 4 91877301 [T/C] NM_001145065 CCSER1 Silent rs1869538 4 91881730 [T/C] NM_001145065 CCSER1 Silent rs7672960 4 91884244 [A/G] NM_001145065 CCSER1 Silent rs7676210 4 91889469 [T/C] NM_001145065 CCSER1 Silent rs10016048 4 91894603 [T/C] NM_001145065 CCSER1 Silent rs1903496 4 91900701 [A/G] NM_001145065 CCSER1 Silent rs2219630 4 91902620 [A/G] NM_001145065 CCSER1 Silent rs6849036 4 91910883 [T/C] NM_001145065 CCSER1 Silent rs17265801 4 91911048 [A/G] NM_001145065 CCSER1 Silent rs11727994 4 91911417 [A/C] NM_001145065 CCSER1 Silent rs17017905 4 91911659 [T/C] NM_001145065 CCSER1 Silent rs2035116 4 91917416 [A/G] NM_001145065 CCSER1 Silent rs17017923 4 91918870 [T/G] NM_001145065 CCSER1 Silent rs17017924 4 91919207 [A/G] NM_001145065 CCSER1 Silent rs2035115 4 91925480 [A/G] NM_001145065 CCSER1 Silent rs6811194 4 91926462 [T/C] NM_001145065 CCSER1 Silent rs7680898 4 91927272 [T/C] NM_001145065 CCSER1 Silent rs9992741 4 91927412 [T/G] NM_001145065 CCSER1 Silent rs1599455 4 91931508 [T/C] NM_001145065 CCSER1 Silent rs2054331 4 91941029 [T/C] NM_001145065 CCSER1 Silent rs6830306 4 91941868 [A/G] NM_001145065 CCSER1 Silent rs10031177 4 91941942 [A/G] NM_001145065 CCSER1 Silent rs6830608 4 91942194 [T/C] NM_001145065 CCSER1 Silent rs6819554 4 91952313 [T/C] NM_001145065 CCSER1 Silent rs10856881 4 91954105 [T/C] NM_001145065 CCSER1 Silent rs1531403 4 91954768 [A/C] NM_001145065 CCSER1 Silent rs10002981 4 91957343 [A/G] NM_001145065 CCSER1 Silent rs2126218 4 91959750 [T/C] NM_001145065 CCSER1 Silent rs1461605 4 91962013 [A/G] NM_001145065 CCSER1 Silent rs10516887 4 91962477 [T/C] NM_001145065 CCSER1 Silent rs13133514 4 91966364 [T/C] NM_001145065 CCSER1 Silent rs1381294 4 91973424 [T/C] NM_001145065 CCSER1 Silent rs6849961 4 91974658 [T/C] NM_001145065 CCSER1 Silent rs10009574 4 91989547 [A/G] NM_001145065 CCSER1 Silent rs7660020 4 91991096 [T/G] NM_001145065 CCSER1 Silent rs12513240 4 91996010 [A/G] NM_001145065 CCSER1 Silent rs10023583 4 92009492 [A/G] NM_001145065 CCSER1 Silent rs12646841 4 92014627 [T/C] NM_001145065 CCSER1 Silent rs11097298 4 92016267 [T/C] NM_001145065 CCSER1 Silent rs12508842 4 92017500 [T/C] NM_001145065 CCSER1 Silent rs13114934 4 92025683 [A/G] NM_001145065 CCSER1 Silent rs6817115 4 92028168 [A/G] NM_001145065 CCSER1 Silent rs17243008 4 92036269 [T/G] NM_001145065 CCSER1 Silent rs17018037 4 92038546 [T/C] NM_001145065 CCSER1 Silent rs11936964 4 92042065 [A/G] NM_001145065 CCSER1 Silent rs7667634 4 92053370 [A/G] NM_001145065 CCSER1 Silent rs7667572 4 92053582 [A/G] NM_001145065 CCSER1 Silent rs17018078 4 92054563 [A/G] NM_001145065 CCSER1 Silent rs13104402 4 92066776 [T/C] NM_001145065 CCSER1 Silent rs10016028 4 92076288 [T/C] NM_001145065 CCSER1 Silent rs1541365 4 92079569 [T/G] NM_001145065 CCSER1 Silent rs17268740 4 92114903 [A/G] NM_001145065 CCSER1 Silent rs4478152 4 92127565 [A/G] NM_001145065 CCSER1 Silent rs11933973 4 92139907 [A/G] NM_001145065 CCSER1 Silent rs872669 4 92141455 [A/C] NM_001145065 CCSER1 Silent rs13146287 4 92142940 [A/G] NM_001145065 CCSER1 Silent rs13122462 4 92142966 [T/C] NM_001145065 CCSER1 Silent rs4693271 4 92151187 [A/G] NM_001145065 CCSER1 Silent rs7671793 4 92154401 [A/G] NM_001145065 CCSER1 Silent rs11930117 4 92158224 [T/G] NM_001145065 CCSER1 Silent rs1544017 4 92159830 [A/G] NM_001145065 CCSER1 Silent rs2204703 4 92163756 [A/G] NM_001145065 CCSER1 Silent rs7675354 4 92172833 [A/G] NM_001145065 CCSER1 Silent rs13151372 4 92178955 [T/C] NM_001145065 CCSER1 Silent rs6815212 4 92179229 [T/C] NM_001145065 CCSER1 Silent rs10028174 4 92184080 [T/C] NM_001145065 CCSER1 Silent rs9986071 4 92185156 [A/G] NM_001145065 CCSER1 Silent rs17018293 4 92185714 [A/G] NM_001145065 CCSER1 Silent rs4331741 4 92193156 [A/C] NM_001145065 CCSER1 Silent rs10003471 4 92200866 [T/C] NM_001145065 CCSER1 Silent rs10006439 4 92201568 [A/C] NM_001145065 CCSER1 Silent rs10516889 4 92207543 [A/G] NM_001145065 CCSER1 Silent rs10033018 4 92218323 [A/G] NM_001145065 CCSER1 Silent rs1969531 4 92225277 [A/G] NM_001145065 CCSER1 Silent rs11725743 4 92231314 [T/C] NM_001145065 CCSER1 Silent rs7693018 4 92238729 [A/C] NM_001145065 CCSER1 Silent rs6532290 4 92240925 [T/G] NM_001145065 CCSER1 Silent rs17018345 4 92244300 [T/C] NM_001145065 CCSER1 Silent rs1358550 4 92245470 [T/G] NM_001145065 CCSER1 Silent rs6532299 4 92251839 [T/C] NM_001145065 CCSER1 Silent rs2870313 4 92267559 [A/G] NM_001145065 CCSER1 Silent rs12507382 4 92280933 [T/C] NM_001145065 CCSER1 Silent rs12507411 4 92281057 [A/C] NM_001145065 CCSER1 Silent rs12512365 4 92281419 [T/C] NM_001145065 CCSER1 Silent rs4128705 4 92283771 [T/G] NM_001145065 CCSER1 Silent rs10516891 4 92284935 [A/G] NM_001145065 CCSER1 Silent rs1919225 4 92286605 [A/G] NM_001145065 CCSER1 Silent rs4146582 4 92287101 [A/G] NM_001145065 CCSER1 Silent rs6837355 4 92304224 [A/G] NM_001145065 CCSER1 Silent rs10856885 4 92309543 [T/C] NM_001145065 CCSER1 Silent rs11943389 4 92310991 [A/G] NM_001145065 CCSER1 Silent rs4411947 4 92316484 [A/G] NM_001145065 CCSER1 Silent rs11735410 4 92330087 [T/C] NM_001145065 CCSER1 Silent rs13123650 4 92349263 [T/C] NM_001145065 CCSER1 Silent rs6845679 4 92350342 [T/C] NM_001145065 CCSER1 Silent rs10022644 4 92352498 [T/C] NM_001145065 CCSER1 Silent rs6824640 4 92354457 [T/C] NM_001145065 CCSER1 Silent rs1922217 4 92357499 [A/G] NM_001145065 CCSER1 Silent rs7659358 4 92358383 [A/G] NM_001145065 CCSER1 Silent rs1922216 4 92366263 [A/G] NM_001145065 CCSER1 Silent rs1922233 4 92368346 [A/G] NM_001145065 CCSER1 Silent rs12646638 4 92380924 [T/C] NM_001145065 CCSER1 Silent rs12649871 4 92381080 [T/C] NM_001145065 CCSER1 Silent rs12646710 4 92381094 [A/G] NM_001145065 CCSER1 Silent rs7675583 4 92399884 [T/C] NM_001145065 CCSER1 Silent rs12498654 4 92405232 [A/G] NM_001145065 CCSER1 Silent rs6838229 4 92420171 [A/G] NM_001145065 CCSER1 Silent rs11731642 4 92421296 [A/G] NM_001145065 CCSER1 Silent rs7677659 4 92431729 [T/C] NM_001145065 CCSER1 Silent rs1607075 4 92434672 [A/C] NM_001145065 CCSER1 Silent rs12641499 4 92439678 [A/G] NM_001145065 CCSER1 Silent rs1516700 4 92451147 [A/C] NM_001145065 CCSER1 Silent rs6852056 4 92452205 [A/G] NM_001145065 CCSER1 Silent rs17283537 4 92454931 [A/G] NM_001145065 CCSER1 Silent rs7697141 4 92457618 [A/G] NM_001145065 CCSER1 Silent rs6532317 4 92466958 [A/G] NM_001145065 CCSER1 Silent rs12152593 4 92472139 [A/C] NM_001145065 CCSER1 Silent rs17018613 4 92477566 [A/G] NM_001145065 CCSER1 Silent rs17284306 4 92483806 [A/G] NM_001145065 CCSER1 Silent rs7675138 4 92496463 [A/G] NM_001145065 CCSER1 Silent rs1516708 4 92502367 [T/C] NM_001145065 CCSER1 Silent rs9991015 4 92520419 [A/C] NM_001145065 CCSER1 EXON Silent rs13113814 4 92539867 [A/G] rs10008605 4 92544156 [A/G] rs11947273 4 92544404 [T/C] rs11946091 4 92566775 [A/G] rs12649563 4 92572499 [A/G] rs12647856 4 92591560 [T/C] rs7670878 4 92606953 [A/G] rs4508848 4 92615579 [A/C] rs11731487 4 92634711 [A/G] rs6532345 4 92651110 [A/G] rs13141601 4 92661382 [T/C] rs4348059 4 92662425 [A/G] rs6820916 4 92666216 [A/C] rs12505028 4 92667871 [T/C] rs4314258 4 92668180 [A/G] rs4128277 4 92670313 [T/C] rs17221444 4 92672743 [A/C] rs4455379 4 92673841 [A/G] rs17018705 4 92678177 [T/G] rs17287631 4 92678634 [T/C] rs6811317 4 92684140 [A/G] rs13106681 4 92685286 [T/C] rs13114360 4 92688140 [A/G] rs9307104 4 92688358 [A/G] rs4615142 4 92690410 [T/C] rs17018727 4 92691062 [T/G] rs11097328 4 92691639 [T/C] rs7671731 4 92691965 [A/G] rs11937169 4 92692108 [A/G] rs4273429 4 92696668 [T/C] rs1564958 4 92706551 [A/C] rs4622965 4 92718180 [T/C] rs1003076 4 92720480 [A/G] rs1485991 4 92734290 [T/C] rs970694 4 92750394 [T/C] rs10034186 4 92750938 [T/G] rs1485989 4 92758836 [T/C] rs1485988 4 92761582 [A/G] rs11941387 4 92770887 [A/G] rs17018839 4 92790543 [A/G] rs10028425 4 92803775 [T/C] rs991345 4 92816815 [T/C] rs1471822 4 92817301 [A/G] rs1120646 4 92820451 [A/G] rs17303960 4 92837584 [A/G] rs1564957 4 92838346 [A/G] rs11944581 4 92839908 [T/C] rs11735191 4 92843943 [A/G] rs321723 4 92845437 [A/G] rs1844346 4 92867432 [T/C] rs17291988 4 92873306 [T/C] rs1489557 4 92883857 [T/C] rs6532349 4 92889426 [T/C] rs6817844 4 92890930 [T/C] rs7672071 4 92897624 [T/G] rs966867 4 92906792 [A/G] rs3864150 4 92919069 [T/C] rs6844960 4 92922397 [T/C] rs4693287 4 92930924 [T/G] rs28826883 4 92955364 [T/C] rs28852518 4 92958963 [T/C] rs11934637 4 92981939 [T/G] rs10032505 4 93009187 [A/G] rs730293 4 93016862 [T/C] rs10023188 4 93030390 [A/C] rs17019118 4 93035856 [T/C] rs6837448 4 93035922 [T/G] rs6532359 4 93044488 [T/G] rs2169202 4 93062161 [A/C] rs17019139 4 93064187 [A/C] rs7699852 4 93072465 [A/G] rs1585428 4 93088664 [A/G] rs6848613 4 93107648 [T/G] rs17019186 4 93113274 [A/G] rs1227423 4 93118886 [T/G] rs7683443 4 93136397 [T/C] rs2199291 4 93136797 [T/G] rs10049958 4 93146144 [A/G] rs10516905 4 93152870 [A/G] rs17019255 4 93161851 [T/C] rs1913301 4 93184838 [A/C] NR_125920 LNCPRESS2 Silent rs17019283 4 93190198 [A/G] NR_125920 LNCPRESS2 Silent rs8180202 4 93198845 [A/G] rs17019288 4 93200832 [A/G] rs992995 4 93236404 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17238193 4 93242743 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6824860 4 93250536 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17019318 4 93255959 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10009241 4 93264193 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17019342 4 93285927 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7685835 4 93288641 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs2089990 4 93300188 [A/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1513460 4 93309526 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13122471 4 93318804 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs4133324 4 93322977 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs4374594 4 93344512 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs5021051 4 93346743 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6844474 4 93354048 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7668752 4 93368860 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs4629410 4 93372969 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs12645728 4 93391877 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs12643954 4 93398759 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6811045 4 93403679 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7684294 4 93416752 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7659159 4 93428335 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7659338 4 93428415 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs4692972 4 93449941 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs4692973 4 93450349 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs11944800 4 93451160 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13140156 4 93451321 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7661958 4 93455880 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17319190 4 93458820 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1993030 4 93467486 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17019538 4 93467552 [A/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7663643 4 93480717 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs2060676 4 93485733 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7682842 4 93489287 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs9685970 4 93504230 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13101814 4 93508181 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs9307120 4 93508896 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6858435 4 93519463 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7668740 4 93539532 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1349350 4 93542768 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs921355 4 93553252 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs2169945 4 93559571 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs34905965 4 93592657 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs9994093 4 93602855 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17019763 4 93612903 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17257464 4 93619350 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs11734837 4 93621420 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs2061889 4 93621793 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs12643444 4 93627019 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1836439 4 93635505 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17019814 4 93638479 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10032050 4 93641094 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6532381 4 93653338 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1369166 4 93659471 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10516914 4 93660667 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10516916 4 93660958 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs4328881 4 93665767 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs954467 4 93665778 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17019871 4 93673153 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17019874 4 93674890 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13141798 4 93675391 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs12507379 4 93678655 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17259489 4 93707044 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7671095 4 93707288 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs28409430 4 93710269 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10856898 4 93723466 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1369169 4 93740409 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6532382 4 93786775 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17019988 4 93800088 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1456359 4 93803563 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1456362 4 93833561 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs2168489 4 93847904 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs3911386 4 93849612 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17327937 4 93872906 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17020035 4 93873811 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7667251 4 93875521 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17020040 4 93890168 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17020045 4 93892487 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs2045316 4 93902882 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13142489 4 93916354 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1039938 4 93918343 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10012031 4 93948103 [A/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17263644 4 93969165 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13135367 4 93975772 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10011751 4 93984995 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17329945 4 93985925 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13126969 4 93987251 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1912718 4 93989892 [A/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10032153 4 93993208 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1511294 4 93994938 [A/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6857940 4 93998463 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs4502650 4 94011311 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs12506519 4 94014156 [A/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13105522 4 94027303 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17020188 4 94034618 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs3843409 4 94034683 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6849575 4 94037375 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs11931441 4 94049823 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17264265 4 94052135 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs11097358 4 94064059 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1354296 4 94075263 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs995906 4 94092083 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17478977 4 94098599 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6821061 4 94100410 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs12645274 4 94106172 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1503223 4 94115801 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs989927 4 94116539 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6857551 4 94117721 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1155646 4 94120374 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7667127 4 94123529 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs12507496 4 94125424 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs3796675 4 94146093 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6846025 4 94150040 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17020286 4 94159658 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7686280 4 94162154 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1433654 4 94162560 [A/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1821342 4 94172097 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7691723 4 94185705 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs11934392 4 94187430 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17020326 4 94209497 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1368727 4 94209719 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs892357 4 94217409 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17020351 4 94219314 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7684707 4 94219390 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6813949 4 94227970 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6854968 4 94233967 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1368730 4 94236828 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1433676 4 94239926 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7698899 4 94242858 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs733942 4 94251270 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1433666 4 94252360 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10002068 4 94252683 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs11943480 4 94252722 [A/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7696884 4 94255091 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs919866 4 94258848 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10028824 4 94262808 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs4693315 4 94283482 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6834311 4 94290979 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1368716 4 94294991 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1905708 4 94297664 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs11737556 4 94300038 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs11733231 4 94300159 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs2082553 4 94301291 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1948016 4 94312343 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1994253 4 94314479 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1385405 4 94316763 [T/G] NM_001286838,NM_001510 GRID2,GRID2 EXON Synonymous_G322G,Synonymous_G417G rs9631724 4 94319668 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs11727464 4 94324475 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7662289 4 94329254 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs11938668 4 94331320 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10018914 4 94333391 [A/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10034345 4 94344042 [A/G] NM_001286838,NM_001510 GRID2,GRID2 EXON Missense_V395I,Missense_V490I rs17020586 4 94344254 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10022753 4 94358023 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10006372 4 94359448 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10012811 4 94361687 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs11097364 4 94367364 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6532406 4 94372673 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6532407 4 94372827 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17020631 4 94380515 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1905726 4 94381871 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1905724 4 94382396 [A/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs2200375 4 94390998 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs11097368 4 94402365 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10030500 4 94406148 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7676645 4 94413681 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1905719 4 94417245 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7655363 4 94423150 [A/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6851153 4 94426942 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs4557232 4 94430437 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13144042 4 94430964 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs4286488 4 94440026 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13131107 4 94446458 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1435473 4 94458391 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6836589 4 94461705 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs11942069 4 94494455 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17020797 4 94497853 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6824100 4 94505733 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13116181 4 94510159 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13121519 4 94516290 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13117931 4 94518801 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17020844 4 94526917 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1435474 4 94528666 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs12503522 4 94543233 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs11728147 4 94543882 [A/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10516928 4 94552306 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6856229 4 94566830 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs9993464 4 94569114 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10516933 4 94570408 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10516936 4 94572516 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10516937 4 94572751 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6848888 4 94572864 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10516939 4 94574700 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs12505284 4 94579992 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6855368 4 94582661 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6532424 4 94585087 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs17020960 4 94591898 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs10516940 4 94594199 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs2859980 4 94594845 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6821896 4 94605867 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13135407 4 94605968 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs4692987 4 94616814 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1036640 4 94617165 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs4693334 4 94618455 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1371357 4 94623649 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs7659517 4 94629367 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs6850113 4 94634302 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs1898905 4 94650978 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs2099701 4 94651669 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs12642295 4 94676316 [A/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs13101891 4 94680540 [T/G] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs4693337 4 94680811 [T/C] NM_001286838,NM_001510 GRID2,GRID2 Silent,Silent rs4619859 4 94699009 [A/G] rs732020 4 94701354 [T/G] rs10084947 4 94702001 [A/G] rs17021105 4 94702064 [T/C] rs4693340 4 94704547 [A/G] rs735256 4 94706706 [T/G] rs12644979 4 94714996 [T/C] rs11097387 4 94717163 [A/C] rs2218120 4 94718878 [T/C] rs10009431 4 94719712 [A/G] rs10024051 4 94720590 [T/C] rs1371356 4 94721315 [T/C] rs6844311 4 94721747 [A/G] rs17021151 4 94721794 [T/C] rs4327453 4 94723268 [T/C] rs10033683 4 94725853 [A/G] rs726899 4 94727622 [T/C] rs10024195 4 94729848 [T/C] rs17021163 4 94730209 [A/G] rs993775 4 94731641 [T/G] rs9991641 4 94733470 [T/C] rs9284593 4 94734922 [T/C] rs9307131 4 94736376 [T/C] rs12499415 4 94739787 [T/C] rs10022714 4 94741522 [A/C] rs11731687 4 94745528 [A/G] rs9996938 4 94746245 [T/C] rs10021588 4 94746370 [A/G] rs10015253 4 94748289 [T/C] rs4264798 4 94760262 [A/G] rs7664530 4 94760857 [T/C] rs7689734 4 94761097 [T/C] rs4485792 4 94761237 [T/C] rs4558831 4 94761551 [A/G] rs7693338 4 94766621 [T/C] rs3924764 4 94769055 [T/C] rs7688836 4 94769686 [A/G] rs4568209 4 94775266 [T/G] rs12643691 4 94778298 [T/C] rs4693349 4 94793323 [T/G] rs7666492 4 94799694 [T/C] rs6818437 4 94802707 [T/C] rs7667683 4 94803402 [A/C] rs7674525 4 94804559 [T/C] rs7698518 4 94807875 [T/C] rs12642948 4 94812609 [T/C] rs7673218 4 94814676 [A/C] rs7692683 4 94816144 [A/G] rs9998896 4 94816722 [A/G] rs2870750 4 94828163 [T/C] rs6813248 4 94830161 [T/C] rs2578165 4 94830314 [T/C] rs2578160 4 94835289 [T/C] rs1898638 4 94839483 [T/C] rs13105254 4 94842776 [T/C] rs9884362 4 94842968 [T/C] rs1595502 4 94854453 [T/C] rs1583661 4 94862267 [A/C] rs1438374 4 94866291 [T/C] rs2618766 4 94877244 [A/G] rs2578125 4 94881319 [T/C] rs10017390 4 94882341 [A/G] rs1898636 4 94883373 [T/C] rs1438371 4 94884472 [T/C] rs13130787 4 94887031 [T/C] rs2578179 4 94889283 [A/G] rs1370823 4 94901470 [T/C] rs1438383 4 94907486 [A/G] rs2578173 4 94911176 [T/G] rs2618758 4 94914066 [A/G] rs203754 4 94926597 [T/C] rs11944674 4 94927323 [T/C] rs280067 4 94949180 [T/C] rs2618764 4 94953631 [T/G] rs9685344 4 94954308 [A/G] rs10856907 4 94958736 [A/G] rs13121813 4 94959526 [A/C] rs12641765 4 94962497 [T/C] rs280117 4 94970758 [T/C] rs11732124 4 94976716 [A/G] rs6837656 4 94986832 [A/G] rs2048299 4 94993624 [T/C] rs17366966 4 94994695 [T/C] rs1509951 4 94995494 [A/G] rs899135 4 95019816 [A/C] rs17301372 4 95027423 [T/C] rs1841925 4 95035175 [A/G] rs17021364 4 95047893 [T/C] NR_125922 LOC101929210 Silent rs17301787 4 95049123 [T/G] NR_125922 LOC101929210 Silent rs1509944 4 95055821 [T/C] NR_125922 LOC101929210 Silent rs10011158 4 95056300 [T/C] NR_125922 LOC101929210 Silent rs9992640 4 95058293 [A/G] NR_125922 LOC101929210 Silent rs10024198 4 95060602 [A/G] NR_125922 LOC101929210 Silent rs1605923 4 95063631 [T/G] NR_125922 LOC101929210 Silent rs4693373 4 95081378 [A/G] NR_125922 LOC101929210 Silent rs4693374 4 95086164 [A/C] NR_125922 LOC101929210 Silent rs7676797 4 95099194 [A/G] NR_125922 LOC101929210 Silent rs2171384 4 95103545 [A/G] NR_125922 LOC101929210 Silent rs4693002 4 95115302 [A/G] NR_125922 LOC101929210 Silent rs6848742 4 95120289 [T/C] NR_125922 LOC101929210 Silent rs7654919 4 95136164 [T/C] NM_001128430,NM_020159,NM_001128429,NR_045644 SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1 Silent,Silent,Silent,Silent rs11723410 4 95147276 [T/C] NM_001128430,NM_020159,NM_001128429,NR_045644 SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1 EXON Missense_S66F,Missense_S66F,Missense_S66F,Silent rs17309887 4 95155505 [T/C] NM_001128430,NM_020159,NM_001128429,NR_045644 SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1 Silent,Silent,Silent,Silent rs10007463 4 95155719 [A/G] NM_001128430,NM_020159,NM_001128429,NR_045644 SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1 Silent,Silent,Silent,Silent rs11097408 4 95165662 [T/C] NM_001128430,NM_020159,NM_001128429,NR_045644 SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1 Silent,Silent,Silent,Silent rs11722476 4 95170839 [A/G] NM_001128430,NM_020159,NM_001128429,NR_045644 SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1 EXON Missense_S247N,Missense_S247N,Missense_S247N,Silent rs7439869 4 95173779 [T/C] NM_001128430,NM_020159,NM_001128429,NR_045644 SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1 EXON Missense_V301A,Missense_V301A,Missense_V301A,Silent rs10029551 4 95185854 [A/G] NM_001128430,NM_020159,NM_001128429,NR_045644,NM_001254949 SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1 Silent,Silent,Silent,Silent,Silent rs2306802 4 95186055 [A/G] NM_001128430,NM_020159,NM_001128429,NR_045644,NM_001254949 SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1 EXON Synonymous_Q493Q,Synonymous_Q493Q,Synonymous_Q493Q,Silent,Synonymous_Q63Q rs7356258 4 95192853 [A/G] NM_001128430,NM_020159,NM_001128429,NR_045644,NM_001254949 SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1 Silent,Silent,Silent,Silent,Silent rs6823404 4 95197520 [T/C] NM_001128430,NM_020159,NM_001128429,NR_045644,NM_001254949 SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1 EXON Synonymous_D613D,Synonymous_D613D,Synonymous_D613D,Silent,Synonymous_D183D rs10027578 4 95207438 [A/G] NM_001128430,NM_020159,NM_001128429,NR_045644,NM_001254949 SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1 Silent,Silent,Silent,Silent,Silent rs8336 4 95211610 [T/C] NM_001128430,NM_020159,NM_001128429,NR_045644,NM_001254949 SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1 EXON Silent,Silent,Silent,Silent,Silent rs8026 4 95212185 [A/G] NM_001128430,NM_020159,NM_001128429,NR_045644,NM_001254949 SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1,SMARCAD1 EXON Silent,Silent,Silent,Silent,Silent rs11936525 4 95220369 [A/G] NM_014485 HPGDS EXON Silent rs10028613 4 95223698 [T/C] NM_014485 HPGDS Silent rs10033662 4 95239462 [A/G] NM_014485 HPGDS Silent rs10461126 4 95248743 [T/G] NM_014485 HPGDS Silent rs10084984 4 95254575 [T/C] NM_014485 HPGDS Silent rs2059605 4 95255212 [T/C] NM_014485 HPGDS Silent rs2289186 4 95255637 [T/G] NM_014485 HPGDS Silent rs11727030 4 95262665 [A/G] NM_014485 HPGDS Silent rs1991316 4 95268272 [T/G] rs6847989 4 95277099 [A/C] rs6532481 4 95277311 [T/G] rs7696494 4 95285174 [A/G] rs12108275 4 95298847 [T/G] rs1609424 4 95301887 [A/G] rs17311887 4 95313228 [T/C] rs10029035 4 95321259 [A/G] rs7685534 4 95328925 [A/C] rs7664215 4 95329157 [T/G] rs10011765 4 95335021 [A/G] rs13435066 4 95339333 [A/G] rs4359908 4 95340174 [T/C] rs4699852 4 95342789 [A/G] rs10008257 4 95356328 [A/G] rs7697295 4 95360346 [T/C] rs2433320 4 95370805 [A/G] rs11946663 4 95382228 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11938329 4 95387691 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6843496 4 95389193 [T/C] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2438140 4 95407821 [T/C] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2452554 4 95409802 [T/C] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2510802 4 95410168 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs774982 4 95410364 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3805301 4 95412692 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2452563 4 95424226 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2433317 4 95428800 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs902980 4 95429441 [T/C] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2510788 4 95438406 [T/C] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2639795 4 95439154 [A/C] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2433324 4 95439956 [A/C] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2162346 4 95447392 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3805288 4 95450770 [T/C] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3805284 4 95458029 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10213504 4 95468433 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2510772 4 95470815 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1493112 4 95472630 [T/C] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2452593 4 95487714 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17021818 4 95491516 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2452600 4 95496882 [T/C] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 EXON Silent,Missense_S136F,Silent,Silent,Missense_S14F,Silent,Silent,Silent rs3828518 4 95500628 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12639887 4 95505975 [T/C] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11722955 4 95506827 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001011515,NM_001256428,NM_001256426,NM_001011516,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 EXON Silent,Synonymous_R274R,Synonymous_R165R,Synonymous_R171R,Synonymous_R152R,Synonymous_R171R,Synonymous_R151R,Synonymous_R171R rs12639623 4 95525186 [T/G] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent rs9307146 4 95529444 [A/C] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent rs966845 4 95539267 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 EXON Missense_A20T,Missense_A345T,Missense_A236T,Missense_A223T,Missense_A374T,Missense_A242T rs4699312 4 95544162 [T/C] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent rs6824181 4 95545821 [A/C] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent rs11732687 4 95555833 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent rs17021917 4 95561279 [T/C] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent rs7690296 4 95561459 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 EXON Missense_T56A,Missense_T381A,Missense_T272A,Missense_T259A,Missense_T410A,Missense_T278A rs1509620 4 95563972 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent rs2280003 4 95575601 [T/C] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent rs13121500 4 95577290 [T/C] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent rs13107595 4 95578588 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 EXON Missense_S167N,Missense_S492N,Missense_S383N,Missense_S370N,Missense_S521N,Missense_S389N rs11097433 4 95579800 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 Silent,Silent,Silent,Silent,Silent,Silent rs14082 4 95586224 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 EXON Silent,Silent,Silent,Silent,Silent,Silent rs1043848 4 95587675 [T/C] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 EXON Silent,Silent,Silent,Silent,Silent,Silent rs1043853 4 95588274 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 EXON Silent,Silent,Silent,Silent,Silent,Silent rs7285 4 95589337 [A/G] NM_001256425,NM_006457,NM_001011513,NM_001256428,NM_001256426,NM_001256427 PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5,PDLIM5 EXON Silent,Silent,Silent,Silent,Silent,Silent rs11944465 4 95594421 [A/C] rs13133845 4 95594616 [A/G] rs6831015 4 95597814 [T/C] rs17022003 4 95602550 [A/C] rs17022008 4 95606136 [T/C] rs17399013 4 95606958 [T/C] rs4699578 4 95607190 [T/C] rs6532503 4 95608023 [T/G] rs7680214 4 95612497 [A/G] rs6850621 4 95620254 [T/C] rs11931151 4 95622305 [T/G] rs6812065 4 95626444 [A/G] rs11735755 4 95628481 [A/G] rs6846079 4 95631307 [A/C] rs9631727 4 95642908 [T/C] rs1553745 4 95644727 [A/G] rs1553744 4 95646654 [A/C] rs4699340 4 95648755 [T/C] rs7663879 4 95649261 [T/C] rs978429 4 95653664 [A/C] rs4348103 4 95678443 [T/G] NR_121610 BMPR1B-DT Silent rs17022094 4 95682424 [T/C] NM_001203 BMPR1B Silent rs10049681 4 95684380 [T/C] NM_001203 BMPR1B Silent rs1553743 4 95687075 [T/G] NM_001203 BMPR1B Silent rs17022123 4 95690975 [T/G] NM_001203 BMPR1B Silent rs4401458 4 95691583 [A/G] NM_001203 BMPR1B Silent rs7694754 4 95692315 [A/G] NM_001203 BMPR1B Silent rs11733843 4 95703047 [T/G] NM_001203 BMPR1B Silent rs12501965 4 95706285 [T/C] NM_001203 BMPR1B Silent rs4599420 4 95708561 [A/G] NM_001203 BMPR1B Silent rs17022227 4 95709925 [A/G] NM_001203 BMPR1B Silent rs2510543 4 95713679 [T/C] NM_001203 BMPR1B Silent rs7677261 4 95718070 [A/G] NM_001203 BMPR1B Silent rs11945770 4 95723924 [A/G] NM_001203 BMPR1B Silent rs4456963 4 95724988 [A/G] NM_001203 BMPR1B Silent rs11723423 4 95732301 [T/C] NM_001203 BMPR1B Silent rs10000023 4 95733906 [T/G] NM_001203 BMPR1B Silent rs7692640 4 95738226 [A/C] NM_001203 BMPR1B Silent rs17022328 4 95748634 [A/G] NM_001203 BMPR1B Silent rs6853333 4 95750415 [A/G] NM_001203 BMPR1B Silent rs6831418 4 95750839 [T/C] NM_001203 BMPR1B Silent rs17428494 4 95750866 [A/G] NM_001203 BMPR1B Silent rs13127472 4 95769791 [A/G] NM_001203 BMPR1B Silent rs10005096 4 95770843 [T/C] NM_001203 BMPR1B Silent rs1544392 4 95775101 [A/G] NM_001203 BMPR1B Silent rs4254781 4 95775606 [T/C] NM_001203 BMPR1B Silent rs17428994 4 95793041 [A/G] NM_001203 BMPR1B Silent rs2719175 4 95794060 [T/C] NM_001203 BMPR1B Silent rs17500892 4 95796952 [A/G] NM_001203 BMPR1B Silent rs17022443 4 95803045 [A/G] NM_001203 BMPR1B Silent rs7678784 4 95803113 [A/G] NM_001203 BMPR1B Silent rs17022449 4 95803792 [A/G] NM_001203 BMPR1B Silent rs1011961 4 95810540 [A/G] NM_001203 BMPR1B Silent rs13116658 4 95811997 [T/C] NM_001203 BMPR1B Silent rs17429196 4 95817017 [A/C] NM_001203 BMPR1B Silent rs3775009 4 95821404 [A/G] NM_001203 BMPR1B Silent rs17022515 4 95829348 [A/G] NM_001203 BMPR1B Silent rs17022528 4 95831407 [T/C] NM_001203 BMPR1B Silent rs1859156 4 95834034 [T/G] NM_001203 BMPR1B Silent rs1295450 4 95841123 [A/G] NM_001203 BMPR1B Silent rs7669822 4 95841960 [T/C] NM_001203 BMPR1B Silent rs3775017 4 95843673 [T/C] NM_001203 BMPR1B Silent rs1444930 4 95845911 [T/C] NM_001203 BMPR1B Silent rs1296143 4 95846470 [A/G] NM_001203 BMPR1B Silent rs11939949 4 95849555 [A/G] NM_001203 BMPR1B Silent rs10021303 4 95856681 [A/G] NM_001203 BMPR1B Silent rs7671870 4 95859913 [A/G] NM_001203 BMPR1B Silent rs6842585 4 95861615 [A/G] NM_001203 BMPR1B Silent rs3796413 4 95867338 [T/C] NM_001203 BMPR1B Silent rs1373651 4 95868525 [A/G] NM_001203 BMPR1B Silent rs1444927 4 95876313 [A/G] NM_001203 BMPR1B Silent rs17402559 4 95889271 [T/C] NM_001203 BMPR1B Silent rs6842938 4 95892128 [A/C] NM_001203 BMPR1B Silent rs1373649 4 95892711 [A/G] NM_001203 BMPR1B Silent rs17343504 4 95901481 [A/G] NM_001203 BMPR1B Silent rs2028761 4 95902177 [A/G] NM_001203 BMPR1B Silent rs3775031 4 95905449 [T/C] NM_001203 BMPR1B Silent rs3755875 4 95907446 [T/C] NM_001203 BMPR1B Silent rs1867542 4 95910958 [T/C] NM_001203 BMPR1B Silent rs1545327 4 95914398 [A/G] NM_001203 BMPR1B Silent rs1545326 4 95914424 [A/C] NM_001203 BMPR1B Silent rs7662504 4 95928570 [A/C] NM_001203,NM_001256792 BMPR1B,BMPR1B Silent,Silent rs12500473 4 95933337 [A/G] NM_001203,NM_001256792 BMPR1B,BMPR1B Silent,Silent rs1347345 4 95938386 [A/G] NM_001203,NM_001256792 BMPR1B,BMPR1B Silent,Silent rs17022885 4 95948640 [T/C] NM_001203,NM_001256792 BMPR1B,BMPR1B Silent,Silent rs10516957 4 95949206 [T/C] NM_001203,NM_001256792 BMPR1B,BMPR1B Silent,Silent rs1434546 4 95954962 [T/G] NM_001203,NM_001256792 BMPR1B,BMPR1B Silent,Silent rs17022918 4 95955095 [A/G] NM_001203,NM_001256792 BMPR1B,BMPR1B Silent,Silent rs13103406 4 95961926 [T/C] NM_001203,NM_001256792 BMPR1B,BMPR1B Silent,Silent rs1434545 4 95969759 [A/G] NM_001203,NM_001256792 BMPR1B,BMPR1B Silent,Silent rs2114534 4 95984379 [T/G] NM_001203,NM_001256792,NM_001256793 BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent rs1863652 4 95991417 [A/G] NM_001203,NM_001256792,NM_001256793 BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent rs1158793 4 96004341 [A/G] NM_001203,NM_001256792,NM_001256793 BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent rs6816834 4 96011233 [A/G] NM_001203,NM_001256792,NM_001256793 BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent rs1469336 4 96014285 [A/G] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs723367 4 96015307 [T/C] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs1560909 4 96020228 [A/G] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs3796432 4 96030402 [T/G] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs3796433 4 96031455 [A/C] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs3796434 4 96031577 [A/G] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs1369087 4 96033978 [T/G] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs6826261 4 96047368 [A/G] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs17023083 4 96052186 [T/C] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs3796441 4 96053225 [T/G] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs3796442 4 96054027 [A/C] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs3796443 4 96061509 [A/G] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs1434538 4 96066672 [T/C] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs3775042 4 96068624 [A/G] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs1970801 4 96070525 [T/G] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B Silent,Silent,Silent,Silent rs6813320 4 96075873 [T/C] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B EXON Silent,Silent,Silent,Silent rs1434536 4 96075965 [T/C] NM_001203,NM_001256792,NM_001256793,NM_001256794 BMPR1B,BMPR1B,BMPR1B,BMPR1B EXON Silent,Silent,Silent,Silent rs1813074 4 96087973 [T/G] NM_003728 UNC5C EXON Silent rs10516959 4 96088849 [T/C] NM_003728 UNC5C EXON Silent rs28435997 4 96089145 [A/G] NM_003728 UNC5C EXON Silent rs17023145 4 96105743 [A/G] NM_003728 UNC5C Silent rs2289043 4 96106322 [A/G] NM_003728 UNC5C EXON Missense_M721T rs3755881 4 96107878 [A/G] NM_003728 UNC5C Silent rs3796462 4 96108829 [T/C] NM_003728 UNC5C Silent rs3796459 4 96116778 [T/G] NM_003728 UNC5C Silent rs3775059 4 96117230 [T/G] NM_003728 UNC5C Silent rs1991946 4 96118696 [A/G] NM_003728 UNC5C Silent rs11737434 4 96122615 [T/C] NM_003728 UNC5C Silent rs3775050 4 96126231 [A/G] NM_003728 UNC5C Silent rs3775049 4 96126271 [A/G] NM_003728 UNC5C Silent rs3775045 4 96126884 [T/C] NM_003728 UNC5C Silent rs2276322 4 96127869 [T/G] NM_003728 UNC5C EXON Synonymous_P604P rs2162448 4 96130145 [A/G] NM_003728 UNC5C Silent rs2571038 4 96135553 [T/C] NM_003728 UNC5C Silent rs2865384 4 96145120 [A/G] NM_003728 UNC5C Silent rs11941383 4 96151958 [T/C] NM_003728 UNC5C Silent rs4699412 4 96160117 [T/C] NM_003728 UNC5C Silent rs7434638 4 96161342 [T/C] NM_003728 UNC5C Silent rs11730446 4 96163244 [A/G] NM_003728 UNC5C Silent rs12642020 4 96165142 [A/G] NM_003728 UNC5C Silent rs4699837 4 96170439 [T/C] NM_003728 UNC5C Silent rs3775003 4 96171211 [T/C] NM_003728 UNC5C Silent rs6838035 4 96179750 [A/C] NM_003728 UNC5C Silent rs17352477 4 96180560 [T/C] NM_003728 UNC5C Silent rs6532537 4 96181408 [A/G] NM_003728 UNC5C Silent rs6847919 4 96189813 [T/C] NM_003728 UNC5C Silent rs1986598 4 96195530 [A/G] NM_003728 UNC5C Silent rs10010112 4 96200216 [T/C] NM_003728 UNC5C Silent rs11097465 4 96204556 [T/C] NM_003728 UNC5C Silent rs10032274 4 96206860 [T/C] NM_003728 UNC5C Silent rs4504262 4 96209804 [T/G] NM_003728 UNC5C Silent rs17023470 4 96213821 [A/G] NM_003728 UNC5C Silent rs6857589 4 96213883 [T/C] NM_003728 UNC5C Silent rs6831808 4 96213928 [A/G] NM_003728 UNC5C Silent rs4699847 4 96220207 [T/C] NM_003728 UNC5C Silent rs17433092 4 96226609 [T/C] NM_003728 UNC5C Silent rs1483735 4 96235521 [A/G] NM_003728 UNC5C Silent rs17023485 4 96235787 [A/G] NM_003728 UNC5C Silent rs10856912 4 96236932 [T/C] NM_003728 UNC5C Silent rs6532549 4 96238873 [A/G] NM_003728 UNC5C Silent rs17023493 4 96240018 [A/G] NM_003728 UNC5C Silent rs17023534 4 96246506 [T/C] NM_003728 UNC5C Silent rs2621462 4 96247498 [T/C] NM_003728 UNC5C Silent rs2626053 4 96255088 [A/G] NM_003728 UNC5C Silent rs10516965 4 96255814 [T/C] NM_003728 UNC5C Silent rs4130507 4 96259062 [T/G] NM_003728 UNC5C Silent rs1552225 4 96260842 [T/C] NM_003728 UNC5C Silent rs2626055 4 96262520 [A/G] NM_003728 UNC5C Silent rs2626035 4 96286793 [A/G] NM_003728 UNC5C Silent rs2626043 4 96289313 [A/G] NM_003728 UNC5C Silent rs1542616 4 96292381 [A/G] NM_003728 UNC5C Silent rs2621458 4 96294936 [T/C] NM_003728 UNC5C Silent rs2626040 4 96295569 [A/G] NM_003728 UNC5C Silent rs2621456 4 96298575 [T/C] NM_003728 UNC5C Silent rs1994175 4 96299024 [T/C] NM_003728 UNC5C Silent rs12644448 4 96299591 [T/G] NM_003728 UNC5C Silent rs10222858 4 96300827 [T/C] NM_003728 UNC5C Silent rs4353913 4 96303313 [T/C] NM_003728 UNC5C Silent rs10461127 4 96304008 [T/C] NM_003728 UNC5C Silent rs10461172 4 96304133 [T/C] NM_003728 UNC5C Silent rs9998018 4 96306407 [T/C] NM_003728 UNC5C Silent rs12513120 4 96307825 [T/C] NM_003728 UNC5C Silent rs6532555 4 96307840 [T/C] NM_003728 UNC5C Silent rs1384862 4 96309211 [A/G] NM_003728 UNC5C Silent rs10516969 4 96310163 [A/G] NM_003728 UNC5C Silent rs1351770 4 96311797 [T/C] NM_003728 UNC5C Silent rs10012134 4 96314856 [A/G] NM_003728 UNC5C Silent rs7679033 4 96314874 [T/C] NM_003728 UNC5C Silent rs6854948 4 96315629 [A/G] NM_003728 UNC5C Silent rs6832475 4 96315706 [T/G] NM_003728 UNC5C Silent rs9998674 4 96316032 [T/G] NM_003728 UNC5C Silent rs17023753 4 96316619 [A/G] NM_003728 UNC5C Silent rs4406027 4 96322804 [A/G] NM_003728 UNC5C Silent rs7691901 4 96330417 [T/G] NM_003728 UNC5C Silent rs9307158 4 96330516 [A/G] NM_003728 UNC5C Silent rs17023779 4 96333037 [T/G] NM_003728 UNC5C Silent rs10516971 4 96341046 [A/G] NM_003728 UNC5C Silent rs9307159 4 96341886 [T/C] NM_003728 UNC5C Silent rs6816601 4 96342237 [A/C] NM_003728 UNC5C Silent rs10017332 4 96342750 [T/G] NM_003728 UNC5C Silent rs12644492 4 96343697 [T/C] NM_003728 UNC5C Silent rs900617 4 96344267 [A/G] NM_003728 UNC5C Silent rs10004779 4 96347978 [T/G] NM_003728 UNC5C Silent rs4277782 4 96348686 [T/C] NM_003728 UNC5C Silent rs4380535 4 96349407 [T/C] NM_003728 UNC5C Silent rs1483749 4 96349420 [T/C] NM_003728 UNC5C Silent rs1483748 4 96353173 [A/G] NM_003728 UNC5C Silent rs1026926 4 96356534 [A/G] NM_003728 UNC5C Silent rs13116794 4 96357927 [T/C] NM_003728 UNC5C Silent rs6854070 4 96358203 [A/G] NM_003728 UNC5C Silent rs3846457 4 96360642 [T/C] NM_003728 UNC5C Silent rs17023881 4 96362183 [T/C] NM_003728 UNC5C Silent rs4699266 4 96363909 [A/G] NM_003728 UNC5C Silent rs7662972 4 96368463 [T/C] NM_003728 UNC5C Silent rs9995935 4 96369736 [A/G] NM_003728 UNC5C Silent rs17381344 4 96370093 [A/G] NM_003728 UNC5C Silent rs265052 4 96372611 [T/C] NM_003728 UNC5C Silent rs265047 4 96373680 [A/G] NM_003728 UNC5C Silent rs265044 4 96374120 [T/C] NM_003728 UNC5C Silent rs13119662 4 96374272 [T/C] NM_003728 UNC5C Silent rs17023932 4 96375542 [T/C] NM_003728 UNC5C Silent rs265042 4 96375818 [A/G] NM_003728 UNC5C Silent rs17023936 4 96376995 [A/G] NM_003728 UNC5C Silent rs11730759 4 96377584 [T/C] NM_003728 UNC5C Silent rs7669439 4 96378484 [T/C] NM_003728 UNC5C Silent rs11936864 4 96379021 [A/G] NM_003728 UNC5C Silent rs3912476 4 96379903 [T/C] NM_003728 UNC5C Silent rs265033 4 96382027 [T/G] NM_003728 UNC5C Silent rs3846452 4 96383256 [A/G] NM_003728 UNC5C Silent rs265030 4 96385457 [T/G] NM_003728 UNC5C Silent rs265029 4 96385593 [A/G] NM_003728 UNC5C Silent rs2629836 4 96388550 [T/C] NM_003728 UNC5C Silent rs4444836 4 96388651 [A/G] NM_003728 UNC5C Silent rs10856917 4 96390834 [T/C] NM_003728 UNC5C Silent rs265061 4 96393102 [T/C] NM_003728 UNC5C Silent rs17383133 4 96394332 [A/G] NM_003728 UNC5C Silent rs10005557 4 96395955 [A/G] NM_003728 UNC5C Silent rs265057 4 96397988 [T/C] NM_003728 UNC5C Silent rs17442528 4 96398364 [T/C] NM_003728 UNC5C Silent rs4505826 4 96406950 [A/G] NM_003728 UNC5C Silent rs6834411 4 96407772 [A/G] NM_003728 UNC5C Silent rs2626047 4 96407962 [T/C] NM_003728 UNC5C Silent rs17383596 4 96408615 [T/C] NM_003728 UNC5C Silent rs2629833 4 96409200 [T/C] NM_003728 UNC5C Silent rs2626048 4 96409981 [A/G] NM_003728 UNC5C Silent rs12640943 4 96410207 [A/C] NM_003728 UNC5C Silent rs17383903 4 96410355 [T/C] NM_003728 UNC5C Silent rs17024066 4 96411907 [A/G] NM_003728 UNC5C Silent rs6532561 4 96416472 [T/C] NM_003728 UNC5C Silent rs10003330 4 96424923 [A/G] NM_003728 UNC5C Silent rs13107936 4 96427086 [A/G] NM_003728 UNC5C Silent rs7699716 4 96428992 [A/G] NM_003728 UNC5C Silent rs1905850 4 96434992 [T/C] NM_003728 UNC5C Silent rs11934067 4 96441556 [A/C] NM_003728 UNC5C Silent rs1564896 4 96448687 [T/C] NM_003728 UNC5C Silent rs10021966 4 96450093 [T/C] NM_003728 UNC5C Silent rs4699429 4 96450925 [A/G] NM_003728 UNC5C Silent rs1545919 4 96454775 [T/C] NM_003728 UNC5C Silent rs17386118 4 96456602 [A/G] NM_003728 UNC5C Silent rs10032931 4 96458433 [T/C] NM_003728 UNC5C Silent rs970689 4 96460537 [A/G] NM_003728 UNC5C Silent rs10008641 4 96461841 [A/G] NM_003728 UNC5C Silent rs11097470 4 96467503 [T/C] NM_003728 UNC5C Silent rs13149449 4 96468160 [A/G] NM_003728 UNC5C Silent rs998065 4 96468386 [A/G] NM_003728 UNC5C Silent rs1351999 4 96475314 [T/G] rs17024180 4 96475689 [A/G] rs13152256 4 96480555 [A/C] rs9307161 4 96484360 [A/C] rs6818365 4 96485224 [A/G] rs1385674 4 96494451 [T/C] rs11931784 4 96494806 [T/C] rs17453026 4 96506439 [T/G] rs4699434 4 96506611 [T/G] rs16996486 4 96508545 [A/C] rs1385677 4 96508701 [A/G] rs7658734 4 96509012 [T/G] rs7665819 4 96510283 [T/C] rs11097473 4 96512246 [T/C] rs1485611 4 96516310 [T/C] rs10024436 4 96517899 [A/G] rs1564893 4 96518564 [T/C] rs11097474 4 96521263 [A/G] rs17387847 4 96522796 [T/G] rs17024229 4 96524095 [T/G] rs264298 4 96527272 [A/G] rs12499437 4 96527801 [T/C] rs264305 4 96531822 [A/G] rs6833223 4 96532925 [A/G] rs11937354 4 96537724 [A/G] rs10516981 4 96541556 [T/C] rs2043656 4 96543990 [A/G] rs11097475 4 96545423 [A/G] rs1369985 4 96545816 [T/C] rs977737 4 96546107 [T/C] rs977738 4 96546227 [T/C] rs11941922 4 96546552 [T/C] rs987382 4 96547093 [T/C] rs1436591 4 96557708 [A/C] rs13106700 4 96560457 [T/C] rs12644144 4 96562035 [A/G] rs10016927 4 96565112 [T/G] rs11727175 4 96567263 [T/C] rs7698569 4 96568238 [T/C] rs17024355 4 96571195 [A/C] rs2865709 4 96577171 [A/G] rs7658020 4 96577810 [A/G] rs6841996 4 96581831 [T/G] rs1436576 4 96600219 [T/C] rs13112339 4 96610670 [T/C] rs17390627 4 96614776 [T/C] rs11097480 4 96614904 [A/G] rs1865848 4 96625942 [A/G] rs1579627 4 96636651 [A/G] rs7685363 4 96640243 [T/C] rs12508603 4 96641816 [A/G] rs1985147 4 96642580 [T/C] rs7692486 4 96658407 [A/C] rs1946742 4 96663991 [T/G] rs1946741 4 96664225 [T/C] rs1946740 4 96664321 [A/G] rs7681417 4 96672472 [T/C] rs17024544 4 96679433 [A/C] rs13147380 4 96681253 [A/C] rs2196515 4 96685664 [A/C] rs1595201 4 96686886 [T/C] rs6851495 4 96688897 [T/C] rs4293789 4 96691264 [A/G] rs4699458 4 96691621 [T/C] rs7669620 4 96704454 [A/G] rs1436561 4 96712286 [A/C] rs13116310 4 96724242 [T/G] rs4463073 4 96724483 [A/G] rs11097485 4 96725043 [T/G] rs13132449 4 96727544 [T/C] rs5012933 4 96728233 [T/C] rs5012929 4 96728284 [A/G] rs11931708 4 96728855 [T/C] rs1583544 4 96729750 [A/G] rs17024592 4 96730586 [A/G] rs4352481 4 96732967 [A/G] rs11938262 4 96733861 [A/G] rs11939292 4 96734419 [T/C] rs1436554 4 96736162 [T/C] rs2043653 4 96741786 [T/C] rs1436548 4 96742723 [T/C] rs6819351 4 96743842 [A/G] rs6819078 4 96743973 [A/G] rs1836899 4 96747103 [A/G] rs16996519 4 96759448 [A/G] rs11733585 4 96760489 [A/G] rs2077513 4 96760894 [A/G] rs1076860 4 96760945 [T/C] rs10516983 4 96761233 [A/G] rs1436536 4 96764785 [T/G] rs7684431 4 96765029 [A/G] rs2054159 4 96783302 [T/C] rs2014345 4 96794027 [A/G] rs10007534 4 96798214 [A/G] rs1369976 4 96807307 [A/G] rs1369979 4 96808602 [T/G] rs13131407 4 96814281 [A/G] rs6848902 4 96816411 [T/C] rs6532586 4 96828109 [A/G] rs10516985 4 96830011 [A/G] rs10516987 4 96831739 [T/G] rs9997683 4 96860000 [T/C] rs6532589 4 96875436 [A/G] rs17024928 4 96877723 [T/G] rs10027211 4 96879552 [T/G] rs17024939 4 96880695 [A/C] rs4699479 4 96893798 [A/G] rs6823094 4 96897523 [T/C] rs17024965 4 96906648 [T/C] rs4699481 4 96908427 [A/G] rs6855600 4 96918295 [A/G] rs7662545 4 96919556 [T/G] rs1514974 4 96923483 [A/G] rs6824429 4 96925910 [A/G] rs263078 4 96930050 [A/G] rs12503593 4 96933043 [A/G] rs17425319 4 96939471 [A/C] rs971524 4 96944577 [T/C] rs7689120 4 96946680 [T/C] rs3737480 4 96952180 [A/C] rs1567957 4 96961891 [T/C] rs997076 4 96963418 [A/C] rs1514976 4 96965849 [T/C] rs2203442 4 96967431 [A/C] rs7695763 4 96977876 [T/C] rs10026084 4 96979391 [A/G] rs13140713 4 96981176 [A/G] rs17025056 4 96982735 [A/G] rs17491976 4 96988350 [T/C] rs12512466 4 97002672 [T/C] rs6825966 4 97008338 [A/G] rs7686416 4 97014317 [T/C] rs4318657 4 97018808 [A/G] rs6851001 4 97024525 [A/G] rs6814006 4 97037142 [T/G] rs17025081 4 97038335 [A/C] rs17427440 4 97053446 [T/G] rs6848939 4 97059594 [A/C] rs10516990 4 97062525 [T/C] rs6844234 4 97074573 [T/C] rs6819348 4 97075010 [A/G] rs7679128 4 97082410 [A/C] rs1840042 4 97083012 [A/G] rs7671563 4 97086618 [A/G] rs12642621 4 97091627 [T/C] rs2042624 4 97094011 [A/G] rs6818950 4 97104881 [T/C] rs7692294 4 97125086 [A/G] rs6852164 4 97135777 [A/G] rs17025209 4 97161412 [T/C] rs4699496 4 97185259 [T/G] rs7682601 4 97216464 [T/C] rs11728676 4 97245414 [A/G] NR_147149 LINC02267 Silent rs4146411 4 97266060 [A/G] NR_147149 LINC02267 Silent rs9998994 4 97274198 [A/G] NR_147149 LINC02267 Silent rs11097505 4 97278349 [A/G] NR_147149 LINC02267 Silent rs1506315 4 97293021 [A/G] NR_147149 LINC02267 Silent rs6817554 4 97293102 [A/G] NR_147149 LINC02267 Silent rs4699509 4 97308914 [T/C] NR_147149 LINC02267 Silent rs17446338 4 97311707 [T/C] NR_147149 LINC02267 Silent rs13112158 4 97327082 [T/G] NR_147149 LINC02267 Silent rs10516995 4 97356378 [T/C] NR_147149 LINC02267 Silent rs10034137 4 97380036 [T/G] NR_147149 LINC02267 Silent rs7442069 4 97391366 [A/C] NR_147149 LINC02267 Silent rs9884206 4 97395575 [A/G] NR_147149 LINC02267 Silent rs7685220 4 97417591 [T/C] NR_147149 LINC02267 Silent rs7693049 4 97419088 [T/G] NR_147149 LINC02267 Silent rs1607062 4 97430897 [T/C] NR_147149 LINC02267 Silent rs4699523 4 97435210 [A/G] NR_147149 LINC02267 Silent rs12646509 4 97435859 [A/G] NR_147149 LINC02267 Silent rs2090376 4 97438464 [A/C] NR_147149 LINC02267 Silent rs1516662 4 97460916 [A/G] NR_147149 LINC02267 Silent rs17025630 4 97472001 [A/C] NR_147149 LINC02267 Silent rs13124250 4 97475233 [T/G] NR_147149 LINC02267 Silent rs10033523 4 97476439 [A/G] NR_147149 LINC02267 Silent rs6834178 4 97489174 [A/G] NR_147149 LINC02267 Silent rs17025646 4 97490002 [A/C] NR_147149 LINC02267 Silent rs954241 4 97490815 [T/C] NR_147149 LINC02267 Silent rs1516666 4 97496521 [A/G] NR_147149 LINC02267 Silent rs17514862 4 97503973 [A/G] NR_147149 LINC02267 Silent rs1400338 4 97505284 [T/C] NR_147149 LINC02267 Silent rs11732439 4 97507670 [A/C] NR_147149 LINC02267 Silent rs4699293 4 97511566 [T/C] NR_147149 LINC02267 Silent rs7674376 4 97523338 [A/G] NR_147149 LINC02267 Silent rs6838767 4 97524510 [A/G] NR_147149 LINC02267 Silent rs7673132 4 97528878 [T/C] NR_147149 LINC02267 Silent rs13151319 4 97529769 [A/G] NR_147149 LINC02267 Silent rs6816701 4 97534146 [T/C] NR_147149 LINC02267 Silent rs7349632 4 97534436 [A/C] NR_147149 LINC02267 Silent rs7670682 4 97540873 [T/C] NR_147149 LINC02267 Silent rs10014469 4 97543099 [A/G] NR_147149 LINC02267 Silent rs7680300 4 97551175 [T/C] NR_147149 LINC02267 Silent rs10006399 4 97552346 [A/G] NR_147149 LINC02267 Silent rs10010351 4 97554148 [A/G] NR_147149 LINC02267 Silent rs7679806 4 97560105 [A/G] NR_147149 LINC02267 Silent rs10033633 4 97563218 [T/C] NR_147149 LINC02267 Silent rs4699530 4 97564929 [T/G] NR_147149 LINC02267 Silent rs6855625 4 97567998 [A/C] NR_147149 LINC02267 Silent rs11735922 4 97570607 [T/C] NR_147149 LINC02267 Silent rs7686119 4 97591085 [A/G] NR_147149 LINC02267 Silent rs4476677 4 97593469 [A/C] NR_147149 LINC02267 Silent rs2178763 4 97599993 [T/C] NR_147149 LINC02267 Silent rs17025751 4 97611764 [A/G] NR_147149 LINC02267 Silent rs6532644 4 97617981 [T/C] NR_147149 LINC02267 Silent rs10024940 4 97621871 [A/G] NR_147149 LINC02267 Silent rs4308434 4 97623215 [T/C] NR_147149 LINC02267 Silent rs10155167 4 97627011 [T/C] NR_147149 LINC02267 Silent rs10004820 4 97627858 [T/C] NR_147149 LINC02267 Silent rs10856922 4 97637435 [A/G] NR_147149 LINC02267 Silent rs10009024 4 97644876 [T/C] NR_147149 LINC02267 Silent rs1922857 4 97652057 [A/G] NR_147149 LINC02267 Silent rs1950166 4 97653130 [A/G] NR_147149 LINC02267 Silent rs17025844 4 97656445 [A/G] NR_147149 LINC02267 Silent rs17025848 4 97662437 [A/G] NR_147149 LINC02267 Silent rs17456988 4 97662454 [T/G] NR_147149 LINC02267 Silent rs1922848 4 97680655 [A/C] NR_147149 LINC02267 Silent rs1922847 4 97680928 [A/C] NR_147149 LINC02267 Silent rs6532649 4 97685296 [A/G] NR_147149 LINC02267 Silent rs10516415 4 97689917 [A/G] NR_147149 LINC02267 Silent rs12509878 4 97695401 [T/G] NR_147149 LINC02267 Silent rs7695101 4 97698070 [A/G] NR_147149 LINC02267 Silent rs1922850 4 97705034 [A/G] NR_147149 LINC02267 Silent rs4579126 4 97737582 [T/C] NR_147149 LINC02267 Silent rs4550934 4 97742963 [A/G] rs1922854 4 97748436 [A/G] rs12509492 4 97751638 [A/G] rs17025930 4 97759914 [T/C] rs17025935 4 97765720 [T/C] rs17025949 4 97774817 [A/C] rs6532654 4 97776070 [A/G] rs9997488 4 97776909 [T/G] rs11936397 4 97779789 [T/C] rs11725440 4 97781855 [A/G] rs7688717 4 97782987 [T/C] rs7670658 4 97783961 [T/C] rs9993037 4 97795082 [T/C] rs12651219 4 97805511 [A/G] rs9994928 4 97807484 [A/C] rs10018387 4 97808218 [A/G] rs9307187 4 97835556 [T/C] rs2107405 4 97860526 [A/G] rs10488827 4 97861141 [A/G] rs10011515 4 97865889 [A/G] rs6825085 4 97874682 [T/C] rs6848042 4 97874724 [A/G] rs7694207 4 97880409 [T/C] rs6830362 4 97889973 [T/C] rs11097533 4 97890868 [A/G] rs981391 4 97891970 [T/C] rs6834049 4 97906295 [A/G] rs13109296 4 97907354 [T/C] rs2525795 4 97908904 [A/C] rs2189572 4 97909469 [T/C] rs7659471 4 97915370 [T/C] rs7673377 4 97917772 [A/C] rs733323 4 97918476 [T/C] rs2903086 4 97921027 [T/G] rs17247004 4 97934806 [A/G] rs17026257 4 97934918 [T/C] rs4141303 4 97935617 [A/G] rs4141304 4 97935662 [A/G] rs17026293 4 97948705 [A/C] rs17026302 4 97949728 [T/C] rs4627872 4 97962970 [A/G] rs2865775 4 97963926 [A/G] rs7695114 4 97968711 [T/C] rs13109193 4 97974722 [T/C] rs11097537 4 97984954 [T/C] rs11942031 4 97985065 [T/C] rs10516420 4 97989968 [A/G] rs9997830 4 98017954 [T/G] rs10049823 4 98024711 [A/G] rs7663291 4 98029212 [T/C] rs2865763 4 98045861 [A/C] rs4131679 4 98050429 [T/C] rs4078016 4 98053277 [A/G] rs11942998 4 98065231 [A/C] rs7693495 4 98069011 [A/G] rs10007859 4 98084663 [A/G] rs10009428 4 98096032 [T/C] rs9715346 4 98098473 [A/G] rs11942542 4 98100051 [A/G] rs11721581 4 98119717 [T/C] rs13111598 4 98121286 [A/G] rs4642255 4 98127149 [A/G] rs10009327 4 98160778 [A/G] rs13126649 4 98170598 [A/G] rs11938519 4 98182517 [T/G] rs7690692 4 98198773 [A/G] rs1462758 4 98200637 [T/C] rs1982619 4 98201071 [A/G] rs11097557 4 98206435 [A/G] rs9307203 4 98208206 [A/C] rs9997401 4 98209654 [A/C] rs17026605 4 98210045 [A/G] rs10213670 4 98219875 [T/C] rs13119820 4 98227375 [T/G] rs11939157 4 98228716 [T/C] rs11936871 4 98230356 [A/G] rs1462778 4 98237090 [T/C] rs1462777 4 98238605 [A/G] rs11737720 4 98240651 [T/C] rs7686247 4 98241354 [T/C] rs1381822 4 98243379 [T/G] rs11728761 4 98258036 [T/G] rs10516422 4 98264960 [A/G] rs12512414 4 98266404 [A/G] rs1462767 4 98270800 [T/C] rs13151057 4 98279501 [T/C] rs2055957 4 98289559 [A/G] NR_102713 STPG2-AS1 Silent rs1350971 4 98291379 [T/C] NR_102713 STPG2-AS1 Silent rs10011676 4 98292053 [A/G] NR_102713 STPG2-AS1 Silent rs4699559 4 98299136 [A/G] NR_102713 STPG2-AS1 Silent rs17026708 4 98316428 [A/G] NR_102713 STPG2-AS1 Silent rs6825634 4 98330337 [A/G] NR_102713 STPG2-AS1 Silent rs17026725 4 98333918 [T/C] NR_102713 STPG2-AS1 Silent rs10002703 4 98371858 [A/G] NR_102713 STPG2-AS1 Silent rs35632782 4 98411916 [T/C] rs11097562 4 98414540 [T/C] rs2865798 4 98425582 [A/G] rs6837008 4 98432390 [T/C] rs17026741 4 98435066 [T/C] rs6822100 4 98435890 [A/G] rs6814444 4 98441586 [T/C] rs9307206 4 98444547 [A/C] rs11941060 4 98457301 [A/C] rs960450 4 98466559 [T/C] rs2136080 4 98471647 [T/C] rs17026796 4 98477808 [A/G] rs13140664 4 98479139 [T/C] rs12649979 4 98513928 [A/G] NM_174952 STPG2 Silent rs13130146 4 98518164 [A/G] NM_174952 STPG2 Silent rs6832426 4 98567966 [A/G] NM_174952 STPG2 Silent rs1508470 4 98575319 [T/C] NM_174952 STPG2 Silent rs10856927 4 98596032 [A/G] NM_174952 STPG2 Silent rs11097568 4 98597993 [A/G] NM_174952 STPG2 Silent rs877376 4 98625497 [A/G] NM_174952 STPG2 Silent rs17026871 4 98633911 [A/G] NM_174952 STPG2 EXON Missense_V420A rs11097573 4 98635524 [T/C] NM_174952 STPG2 Silent rs17545594 4 98652689 [A/G] NM_174952 STPG2 Silent rs11729826 4 98657190 [T/G] NM_174952 STPG2 Silent rs7657354 4 98743020 [T/C] NM_174952 STPG2 Silent rs11735193 4 98761900 [T/C] NM_174952 STPG2 Silent rs11934013 4 98765347 [A/G] NM_174952 STPG2 Silent rs17027042 4 98815858 [T/C] NM_174952 STPG2 Silent rs722024 4 98819843 [A/C] NM_174952 STPG2 Silent rs7668876 4 98837843 [A/G] NM_174952 STPG2 Silent rs968854 4 98837863 [T/C] NM_174952 STPG2 Silent rs921521 4 98838339 [A/G] NM_174952 STPG2 Silent rs1215054 4 98863009 [T/G] NM_174952 STPG2 Silent rs783961 4 98885670 [T/C] NM_174952 STPG2 Silent rs13434650 4 98889886 [A/G] NM_174952 STPG2 Silent rs783960 4 98893437 [A/G] NM_174952 STPG2 EXON Synonymous_D309D rs13133355 4 98919415 [A/G] NM_174952 STPG2 Silent rs11097592 4 98927532 [A/G] NM_174952 STPG2 Silent rs783919 4 98948950 [A/G] NM_174952 STPG2 Silent rs783922 4 98965614 [T/C] NM_174952 STPG2 Silent rs7677523 4 98965696 [T/C] NM_174952 STPG2 Silent rs1967977 4 98966141 [A/G] NM_174952 STPG2 Silent rs4699323 4 98967484 [A/G] NM_174952 STPG2 Silent rs2865983 4 99033352 [T/C] NM_174952 STPG2 Silent rs2903153 4 99057457 [T/C] NM_174952 STPG2 Silent rs6854802 4 99065480 [A/C] rs17027299 4 99078105 [T/C] rs13150465 4 99094892 [A/G] rs4699611 4 99097492 [T/G] rs9994641 4 99101605 [T/C] rs13134014 4 99104879 [A/G] rs6820691 4 99105055 [T/C] rs10516427 4 99114106 [T/C] rs6820913 4 99125659 [A/C] rs2866006 4 99147896 [T/C] rs13150538 4 99152631 [A/G] rs17494998 4 99160699 [T/C] rs3974886 4 99172175 [T/C] rs28478192 4 99181521 [T/C] rs2034677 4 99187874 [A/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs10003496 4 99197839 [A/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs10028275 4 99208535 [A/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs10005811 4 99208603 [A/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs603215 4 99214851 [A/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs17027456 4 99235747 [A/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs17561798 4 99235941 [A/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs10516428 4 99237439 [T/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs6846417 4 99259807 [A/C] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs6854095 4 99261097 [T/C] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs6532732 4 99265074 [A/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs10028330 4 99268949 [T/C] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs10003372 4 99276320 [T/C] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs10002767 4 99298166 [A/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs17027526 4 99302166 [T/C] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs17027533 4 99304023 [G/C] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs3775540 4 99304544 [A/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs3756088 4 99309404 [A/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs13103626 4 99317251 [A/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs9997337 4 99318688 [T/C] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs17027564 4 99322274 [A/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs2063745 4 99322767 [T/G] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs1399243 4 99328306 [T/C] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs7671104 4 99330630 [T/C] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs10516430 4 99337881 [T/C] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 Silent,Silent,Silent,Silent,Silent,Silent rs4699634 4 99364621 [T/C] NM_021159,NM_001100430,NM_001100426,NM_001100427,NM_001100428,NM_001100429 RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1,RAP1GDS1 EXON Silent,Silent,Silent,Silent,Silent,Silent rs13119703 4 99366583 [A/G] rs12503056 4 99369061 [A/G] rs2004316 4 99381148 [T/C] rs2090118 4 99387827 [A/G] rs17027607 4 99392101 [A/C] NM_005723 TSPAN5 EXON Silent rs4303985 4 99399748 [T/G] NM_005723 TSPAN5 Silent rs6854915 4 99407200 [A/G] NM_005723 TSPAN5 Silent rs7677026 4 99411237 [A/G] NM_005723 TSPAN5 Silent rs4527483 4 99421741 [T/C] NM_005723 TSPAN5 Silent rs4699638 4 99422081 [A/G] NM_005723 TSPAN5 Silent rs10009693 4 99423280 [T/C] NM_005723 TSPAN5 Silent rs10023791 4 99425353 [A/G] NM_005723 TSPAN5 Silent rs955931 4 99428163 [T/C] NM_005723 TSPAN5 Silent rs17499015 4 99441349 [T/C] NM_005723 TSPAN5 Silent rs7695093 4 99443585 [A/G] NM_005723 TSPAN5 Silent rs10004753 4 99447433 [T/G] NM_005723 TSPAN5 Silent rs6835899 4 99458977 [A/G] NM_005723 TSPAN5 Silent rs2037832 4 99459528 [T/C] NM_005723 TSPAN5 Silent rs1919211 4 99463989 [A/G] NM_005723 TSPAN5 Silent rs6532748 4 99468567 [A/G] NM_005723 TSPAN5 Silent rs1554849 4 99474774 [A/G] NM_005723 TSPAN5 Silent rs17027701 4 99477102 [T/C] NM_005723 TSPAN5 Silent rs13141997 4 99478756 [T/C] NM_005723 TSPAN5 Silent rs10021296 4 99483238 [T/C] NM_005723 TSPAN5 Silent rs4554081 4 99484863 [A/G] NM_005723 TSPAN5 Silent rs1534555 4 99488312 [T/C] NM_005723 TSPAN5 Silent rs17027758 4 99490578 [A/C] NM_005723 TSPAN5 Silent rs7691465 4 99491187 [T/C] NM_005723 TSPAN5 Silent rs11944636 4 99493776 [A/G] NM_005723 TSPAN5 Silent rs1547382 4 99493955 [T/C] NM_005723 TSPAN5 Silent rs1406311 4 99495460 [A/G] NM_005723 TSPAN5 Silent rs10026446 4 99498899 [A/G] NM_005723 TSPAN5 Silent rs9999318 4 99500546 [T/C] NM_005723 TSPAN5 Silent rs1358548 4 99504635 [T/C] NM_005723 TSPAN5 Silent rs4699353 4 99509133 [A/G] NM_005723 TSPAN5 Silent rs17027806 4 99509229 [T/C] NM_005723 TSPAN5 Silent rs1893714 4 99510279 [A/G] NM_005723 TSPAN5 Silent rs17027845 4 99527572 [A/C] NM_005723 TSPAN5 Silent rs846015 4 99528449 [T/C] NM_005723 TSPAN5 Silent rs2000814 4 99528486 [T/C] NM_005723 TSPAN5 Silent rs4699661 4 99534928 [A/G] NM_005723 TSPAN5 Silent rs7659885 4 99539290 [A/G] NM_005723 TSPAN5 Silent rs2866015 4 99539498 [T/G] NM_005723 TSPAN5 Silent rs9684705 4 99542125 [T/C] NM_005723 TSPAN5 Silent rs12504979 4 99546654 [T/C] NM_005723 TSPAN5 Silent rs12509170 4 99546928 [T/G] NM_005723 TSPAN5 Silent rs3941 4 99548182 [A/G] NM_005723 TSPAN5 Silent rs10026666 4 99551907 [T/C] NM_005723 TSPAN5 Silent rs12509052 4 99555740 [T/C] NM_005723 TSPAN5 Silent rs10489126 4 99556496 [T/C] NM_005723 TSPAN5 Silent rs1528545 4 99561045 [T/C] NM_005723 TSPAN5 Silent rs871473 4 99561995 [T/C] NM_005723 TSPAN5 Silent rs883509 4 99563676 [A/G] NM_005723 TSPAN5 Silent rs10856938 4 99565852 [T/C] NM_005723 TSPAN5 Silent rs6821935 4 99569639 [A/G] NM_005723 TSPAN5 Silent rs6829297 4 99571085 [T/C] NM_005723 TSPAN5 Silent rs12507328 4 99573350 [T/C] NM_005723 TSPAN5 Silent rs17027889 4 99573992 [A/G] NM_005723 TSPAN5 Silent rs12512460 4 99583513 [T/C] NR_148380 LOC105377342 Silent rs7675896 4 99583639 [A/G] NR_148380 LOC105377342 Silent rs6819703 4 99595604 [T/C] rs4699665 4 99598549 [T/C] rs1528009 4 99599578 [T/G] rs7680513 4 99608363 [T/C] rs4621437 4 99613485 [T/C] rs1003174 4 99617267 [A/G] rs12507086 4 99619286 [A/G] rs2178125 4 99620154 [T/C] rs11933609 4 99620707 [A/G] rs1528007 4 99628067 [T/C] rs4146004 4 99632473 [A/G] rs17027976 4 99636215 [A/G] rs7668409 4 99636952 [T/C] rs10010015 4 99637965 [T/C] rs10016647 4 99640223 [T/G] rs17566763 4 99643472 [A/G] rs10213420 4 99651480 [A/G] rs13134776 4 99657397 [A/G] rs4699667 4 99661738 [T/C] rs4235430 4 99668311 [A/G] rs4699670 4 99672392 [T/C] rs4493540 4 99674593 [A/G] rs971169 4 99676081 [T/C] rs11097632 4 99687168 [A/G] rs10010115 4 99698254 [T/C] rs4616760 4 99699141 [A/G] rs17028075 4 99700351 [A/G] rs17028081 4 99701724 [A/G] rs7438406 4 99702148 [T/C] rs6532765 4 99703142 [A/G] rs894810 4 99707614 [A/G] rs2083865 4 99708057 [T/C] rs2903158 4 99714727 [T/G] rs1867343 4 99719961 [T/C] rs7696219 4 99723669 [T/C] rs12649579 4 99728276 [A/G] rs10011147 4 99730246 [A/G] rs4699675 4 99730691 [A/G] rs13114194 4 99740952 [T/C] rs12331010 4 99743545 [A/G] rs6822279 4 99745705 [A/C] rs12649469 4 99748988 [T/C] rs10446681 4 99772547 [A/C] rs4401453 4 99774183 [T/C] rs6851217 4 99774466 [T/C] rs17028201 4 99780288 [A/G] rs11097638 4 99781443 [T/G] rs6532770 4 99783669 [A/C] rs2165944 4 99783733 [A/G] rs7669736 4 99788605 [T/G] rs10032966 4 99789979 [T/C] rs10433891 4 99800310 [A/G] NM_001130678,NM_001130679,NM_001968,NM_001331017 EIF4E,EIF4E,EIF4E,EIF4E EXON Silent,Silent,Silent,Silent rs994636 4 99808872 [T/C] NM_001130678,NM_001130679,NM_001968,NM_001331017 EIF4E,EIF4E,EIF4E,EIF4E Silent,Silent,Silent,Silent rs17570252 4 99822905 [T/C] NM_001130678,NM_001130679,NM_001968,NM_001331017 EIF4E,EIF4E,EIF4E,EIF4E Silent,Silent,Silent,Silent rs6834230 4 99847876 [T/C] NM_001130678,NM_001130679,NM_001968,NM_001331017 EIF4E,EIF4E,EIF4E,EIF4E Silent,Silent,Silent,Silent rs11723037 4 99850126 [A/G] NM_001130678,NM_001130679,NM_001968,NM_001331017 EIF4E,EIF4E,EIF4E,EIF4E EXON Silent,Silent,Silent,Silent rs13107892 4 99852395 [T/C] rs9999702 4 99863585 [T/C] rs4699693 4 99867860 [A/G] rs6810489 4 99877445 [T/G] rs11726503 4 99883163 [A/G] rs1230190 4 99892196 [A/C] rs11939480 4 99894475 [T/G] rs1230194 4 99896306 [A/G] rs7356525 4 99899193 [A/G] rs1230173 4 99909462 [A/G] rs10035037 4 99918661 [A/C] NM_015143 METAP1 Silent rs1230182 4 99938721 [A/G] NM_015143 METAP1 Silent rs6841819 4 99944097 [A/G] NM_015143 METAP1 Silent rs1453871 4 99948406 [A/G] NM_015143 METAP1 Silent rs1037476 4 99952607 [T/C] NM_015143 METAP1 Silent rs1037475 4 99952710 [A/G] NM_015143 METAP1 Silent rs7670154 4 99955535 [T/G] NM_015143 METAP1 Silent rs17028397 4 99959569 [A/C] NM_015143 METAP1 Silent rs17216080 4 99959932 [T/C] NM_015143 METAP1 Silent rs1230185 4 99962758 [T/C] NM_015143 METAP1 Silent rs1230186 4 99963407 [T/G] NM_015143 METAP1 Silent rs1230210 4 99967691 [T/C] NM_015143 METAP1 Silent rs1238741 4 99983312 [T/C] NM_015143 METAP1 EXON Silent rs1230165 4 99986373 [A/G] rs7664906 4 99988567 [A/C] rs1230154 4 99988659 [T/C] rs17595186 4 99988713 [A/G] rs1230155 4 99989259 [A/G] rs1230157 4 99989808 [A/C] rs7662987 4 99991642 [T/C] rs7669660 4 99992602 [T/C] NM_000671 ADH5 EXON Silent rs11547772 4 99992793 [A/C] NM_000671 ADH5 EXON Silent rs6827292 4 99992994 [T/C] NM_000671 ADH5 EXON Silent rs28730647 4 99993150 [A/G] NM_000671 ADH5 EXON Silent rs1803037 4 99993151 [T/C] NM_000671 ADH5 EXON Silent rs28730644 4 99993686 [T/C] NM_000671 ADH5 Silent rs17595424 4 99993869 [T/G] NM_000671 ADH5 Silent rs1235433 4 99994905 [A/G] NM_000671 ADH5 Silent rs7683802 4 99995138 [T/G] NM_000671 ADH5 Silent rs1154415 4 99999033 [T/C] NM_000671 ADH5 Silent rs13119035 4 99999130 [A/G] NM_000671 ADH5 Silent rs13146416 4 99999160 [T/C] NM_000671 ADH5 Silent rs13125919 4 99999848 [T/C] NM_000671 ADH5 Silent rs1154412 4 100001247 [T/C] NM_000671 ADH5 Silent rs6852848 4 100001932 [A/T] NM_000671 ADH5 Silent rs7683704 4 100004226 [T/C] NM_000671 ADH5 Silent rs3018048 4 100005538 [T/C] NM_000671 ADH5 Silent rs17028505 4 100006184 [T/C] NM_000671 ADH5 Silent rs1154410 4 100006645 [A/G] NM_000671 ADH5 Silent rs6846829 4 100008190 [A/G] NM_000671 ADH5 Silent rs1154405 4 100008750 [A/G] NM_000671 ADH5 Silent rs1154400 4 100010010 [T/C] NR_037884 LOC100507053 EXON Silent rs2851301 4 100010127 [T/C] NR_037884 LOC100507053 EXON Silent rs17216887 4 100010273 [G/C] NR_037884 LOC100507053 EXON Silent rs13132688 4 100011171 [A/G] NR_037884 LOC100507053 Silent rs10006953 4 100011966 [C/G] NR_037884 LOC100507053 Silent rs1311615 4 100012261 [A/G] NR_037884 LOC100507053 Silent rs1311616 4 100012303 [T/G] NR_037884 LOC100507053 Silent rs1312200 4 100012357 [A/G] NR_037884 LOC100507053 Silent rs1311617 4 100012425 [T/G] NR_037884 LOC100507053 Silent rs7681427 4 100013959 [A/C] NR_037884 LOC100507053 Silent rs7687322 4 100014342 [A/G] NR_037884 LOC100507053 Silent rs2602836 4 100014805 [A/G] NR_037884 LOC100507053 Silent rs2851277 4 100022910 [T/G] NR_037884 LOC100507053 Silent rs6822742 4 100023959 [A/G] NR_037884 LOC100507053 Silent rs7690613 4 100025633 [A/G] NR_037884 LOC100507053 Silent rs2602865 4 100034841 [T/C] NR_037884 LOC100507053 Silent rs2602877 4 100039847 [T/A] NR_037884 LOC100507053 Silent rs2602878 4 100039953 [T/G] NR_037884 LOC100507053 Silent rs2602886 4 100041179 [A/G] NR_037884 LOC100507053 Silent rs13138318 4 100041536 [T/G] NR_037884 LOC100507053 Silent rs6532795 4 100042221 [T/C] NR_037884 LOC100507053 Silent rs6532796 4 100042242 [A/G] NR_037884 LOC100507053 Silent rs3828541 4 100042262 [A/G] NR_037884 LOC100507053 Silent rs7698301 4 100042409 [T/C] NR_037884 LOC100507053 Silent rs3018045 4 100042821 [T/C] NR_037884 LOC100507053 Silent rs2602891 4 100043284 [T/C] NR_037884 LOC100507053 Silent rs2851253 4 100043505 [T/G] NR_037884 LOC100507053 Silent rs2924583 4 100044640 [T/C] NR_037884 LOC100507053 Silent rs10097 4 100045408 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 EXON Silent,Silent,Silent,Silent rs29001238 4 100045479 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 EXON Silent,Silent,Silent,Silent rs1042364 4 100045574 [T/C] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 EXON Silent,Silent,Silent,Silent rs1126673 4 100045616 [T/C] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 EXON Silent,Missense_V393I,Missense_V393I,Missense_V374I rs2602895 4 100045840 [T/C] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs2851248 4 100045974 [T/C] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs2851247 4 100046091 [C/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs2851246 4 100046104 [T/C] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs2602896 4 100046207 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs1126672 4 100047812 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 EXON Silent,Synonymous_L370L,Synonymous_L370L,Synonymous_L351L rs29001219 4 100048386 [T/C] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 EXON Silent,Missense_R337H,Missense_R337H,Missense_R318H rs1126671 4 100048414 [T/C] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 EXON Silent,Missense_I328V,Missense_I328V,Missense_I309V rs6837685 4 100049145 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs4699710 4 100051819 [T/C] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs2156732 4 100053297 [T/A] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs4148888 4 100054192 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs17217949 4 100054312 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs6532798 4 100054827 [T/C] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 EXON Silent,Silent,Silent,Silent rs13143133 4 100054970 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs6532799 4 100055156 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs17218073 4 100055739 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs13112176 4 100055825 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs4148887 4 100055862 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs17218141 4 100055908 [T/C] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs17218162 4 100056060 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs3805322 4 100056998 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs17218239 4 100057020 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs13133647 4 100058727 [T/C] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs6532800 4 100058884 [T/C] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs7669636 4 100059312 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs7670060 4 100059568 [T/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs7670241 4 100059619 [T/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs4699713 4 100060513 [T/C] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs4699714 4 100060538 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs17817868 4 100060623 [T/C] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs17218560 4 100060794 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs13148577 4 100060836 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs13110176 4 100062430 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs13110764 4 100062466 [A/G] NR_037884,NM_001306171,NM_001306172,NM_000670 LOC100507053,ADH4,ADH4,ADH4 Silent,Silent,Silent,Silent rs1800759 4 100065509 [T/G] NR_037884 LOC100507053 Silent rs4140388 4 100065734 [G/C] NR_037884 LOC100507053 Silent rs3762894 4 100066084 [T/C] NR_037884 LOC100507053 Silent rs4699716 4 100066125 [A/G] NR_037884 LOC100507053 Silent rs4699717 4 100066137 [T/C] NR_037884 LOC100507053 Silent rs4148884 4 100066287 [T/C] NR_037884 LOC100507053 Silent rs4148883 4 100066332 [T/C] NR_037884 LOC100507053 Silent rs2226896 4 100067337 [A/G] NR_037884 LOC100507053 Silent rs4699720 4 100073261 [T/C] NR_037884 LOC100507053 Silent rs16996598 4 100077749 [A/G] NR_037884 LOC100507053 EXON Silent rs7678936 4 100078890 [A/C] NR_037884 LOC100507053 Silent rs1540053 4 100082154 [T/C] NR_037884,NR_028270 LOC100507053,PCNAP1 EXON Silent,Silent rs6828364 4 100117939 [A/G] NR_037884 LOC100507053 Silent rs6814114 4 100122819 [T/G] NR_037884 LOC100507053 Silent rs2051428 4 100123186 [A/G] NR_037884 LOC100507053 Silent rs2000864 4 100123776 [A/C] NR_037884 LOC100507053 Silent rs4283664 4 100126510 [T/C] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs17219626 4 100126896 [A/G] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs4147548 4 100126987 [A/G] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs11097660 4 100127138 [A/G] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs4147547 4 100127311 [T/G] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs10025760 4 100128547 [A/C] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs4147546 4 100128682 [T/C] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 EXON Silent,Synonymous_V295V,Silent,Synonymous_V295V rs4147545 4 100128753 [T/C] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs10026121 4 100128780 [A/G] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs11097661 4 100129459 [T/C] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs3857224 4 100129685 [T/C] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs28720153 4 100131582 [T/C] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 EXON Silent,Missense_I114V,Silent,Missense_I114V rs28720152 4 100131618 [A/C] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 EXON Silent,Missense_C102G,Silent,Missense_C102G rs17219837 4 100131746 [G/C] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs17028735 4 100132432 [A/G] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs2187483 4 100134103 [T/G] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs6843298 4 100137393 [A/G] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 EXON Silent,Synonymous_L15L,Silent,Synonymous_L15L rs6820368 4 100137494 [T/C] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs4699733 4 100137534 [C/G] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs9995799 4 100138538 [A/C] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 Silent,Silent,Silent,Silent rs4699735 4 100140306 [A/T] NR_037884,NM_001102470,NR_132990,NM_000672 LOC100507053,ADH6,ADH6,ADH6 EXON Silent,Missense_C2S,Silent,Missense_C2S rs10002894 4 100141240 [A/G] NR_037884 LOC100507053 Silent rs10008281 4 100142302 [A/C] NR_037884 LOC100507053 Silent rs6830685 4 100143184 [A/G] NR_037884 LOC100507053 Silent rs6532807 4 100144005 [T/C] NR_037884 LOC100507053 Silent rs12510722 4 100147101 [A/G] NR_037884 LOC100507053 Silent rs2173199 4 100171379 [A/G] NR_037884 LOC100507053 Silent rs13142106 4 100178151 [A/G] NR_037884 LOC100507053 Silent rs12506882 4 100185431 [A/G] NR_037884 LOC100507053 Silent rs1566141 4 100192460 [A/G] NR_037884 LOC100507053 Silent rs12504387 4 100193979 [T/G] NR_037884 LOC100507053 Silent rs13123099 4 100194517 [A/G] NR_037884 LOC100507053 Silent rs6811453 4 100194977 [A/G] NR_037884 LOC100507053 Silent rs12512110 4 100195815 [T/G] NR_037884 LOC100507053 Silent rs28364342 4 100197176 [A/C] NR_037884 LOC100507053 Silent rs7684674 4 100197359 [A/C] NR_037884 LOC100507053 Silent rs28364336 4 100198814 [T/C] NR_037884,NM_000667 LOC100507053,ADH1A Silent,Silent rs28364333 4 100200153 [T/C] NR_037884,NM_000667 LOC100507053,ADH1A Silent,Silent rs3819197 4 100200509 [T/C] NR_037884,NM_000667 LOC100507053,ADH1A Silent,Silent rs1229976 4 100202078 [T/C] NR_037884,NM_000667 LOC100507053,ADH1A Silent,Silent rs2276332 4 100203447 [A/C] NR_037884,NM_000667 LOC100507053,ADH1A Silent,Silent rs6828526 4 100205887 [A/G] NR_037884,NM_000667 LOC100507053,ADH1A EXON Silent,Synonymous_Y111Y rs28521649 4 100208335 [T/C] NR_037884,NM_000667 LOC100507053,ADH1A Silent,Silent rs4147532 4 100211786 [T/C] NR_037884,NM_000667 LOC100507053,ADH1A Silent,Silent rs4147531 4 100212197 [A/G] NR_037884 LOC100507053 Silent rs2173198 4 100212581 [T/C] NR_037884 LOC100507053 Silent rs1229966 4 100213433 [A/G] NR_037884 LOC100507053 Silent rs6835371 4 100214086 [T/G] NR_037884 LOC100507053 Silent rs35743364 4 100214460 [A/G] NR_037884 LOC100507053 Silent rs6812015 4 100215603 [A/G] NR_037884 LOC100507053 Silent rs1826909 4 100217743 [T/C] NR_037884 LOC100507053 Silent rs13103321 4 100220240 [T/G] NR_037884 LOC100507053 Silent rs28914790 4 100227817 [T/C] NM_001286650,NM_000668 ADH1B,ADH1B EXON Silent,Silent rs28914788 4 100228891 [T/C] NM_001286650,NM_000668 ADH1B,ADH1B EXON Silent,Silent rs7673353 4 100231076 [T/C] NM_001286650,NM_000668 ADH1B,ADH1B Silent,Silent rs17028834 4 100232600 [T/C] NM_001286650,NM_000668 ADH1B,ADH1B Silent,Silent rs13133908 4 100232624 [T/G] NM_001286650,NM_000668 ADH1B,ADH1B Silent,Silent rs1789883 4 100236375 [A/G] NM_001286650,NM_000668 ADH1B,ADH1B Silent,Silent rs1693457 4 100236762 [T/C] NM_001286650,NM_000668 ADH1B,ADH1B Silent,Silent rs7435646 4 100237492 [A/T] NM_001286650,NM_000668 ADH1B,ADH1B Silent,Silent rs2075633 4 100238998 [T/C] NM_001286650,NM_000668 ADH1B,ADH1B Silent,Silent rs4147536 4 100239112 [A/C] NM_001286650,NM_000668 ADH1B,ADH1B Silent,Silent rs1235416 4 100240921 [T/G] NM_001286650,NM_000668 ADH1B,ADH1B Silent,Silent rs1353621 4 100241575 [T/C] NM_001286650,NM_000668 ADH1B,ADH1B Silent,Silent rs1159918 4 100243009 [A/C] rs1229982 4 100243932 [T/G] rs3811802 4 100244221 [A/G] rs6839995 4 100244355 [A/C] rs1693439 4 100245489 [A/G] rs9307239 4 100246937 [T/C] rs2213041 4 100247351 [A/C] rs1789891 4 100250419 [A/C] rs2173201 4 100250970 [A/C] rs3846448 4 100254935 [A/G] rs1229980 4 100255275 [C/G] rs1229978 4 100256199 [T/C] rs1789896 4 100256984 [A/G] rs3114046 4 100257432 [T/C] rs1614972 4 100258155 [T/C] NM_000669,NR_133005 ADH1C,ADH1C Silent,Silent rs1662033 4 100258381 [T/G] NM_000669,NR_133005 ADH1C,ADH1C Silent,Silent rs904095 4 100263383 [A/G] NM_000669,NR_133005 ADH1C,ADH1C Silent,Silent rs904096 4 100263584 [T/G] NM_000669,NR_133005 ADH1C,ADH1C Silent,Silent rs1789911 4 100263778 [T/C] NM_000669,NR_133005 ADH1C,ADH1C Silent,Silent rs283410 4 100264399 [A/G] NM_000669,NR_133005 ADH1C,ADH1C Silent,Silent rs1693429 4 100267421 [T/C] NM_000669,NR_133005 ADH1C,ADH1C Silent,Silent rs3762896 4 100268131 [T/C] NM_000669,NR_133005 ADH1C,ADH1C Silent,Silent rs4147542 4 100268553 [T/C] NM_000669,NR_133005 ADH1C,ADH1C Silent,Silent rs1789921 4 100269202 [A/G] NM_000669,NR_133005 ADH1C,ADH1C Silent,Silent rs283415 4 100270607 [T/C] NM_000669,NR_133005 ADH1C,ADH1C Silent,Silent rs4147541 4 100274157 [C/G] NM_000669,NR_133005 ADH1C,ADH1C EXON Silent,Silent rs1789924 4 100274286 [T/C] rs11499823 4 100274749 [A/G] rs4699741 4 100278697 [T/C] rs1662037 4 100278819 [A/G] rs1614377 4 100279332 [A/G] rs2851300 4 100279824 [T/C] rs166892 4 100282765 [T/C] rs7661978 4 100284199 [T/C] rs1826906 4 100301048 [T/C] rs1372680 4 100304545 [A/C] rs10516440 4 100305393 [A/G] rs2851293 4 100307378 [T/C] rs284782 4 100310907 [T/C] rs7667212 4 100318099 [T/C] rs1442493 4 100321365 [A/G] rs4699748 4 100321443 [A/G] rs2584461 4 100321573 [T/C] rs991316 4 100322445 [T/C] rs17587689 4 100324071 [A/G] rs17028991 4 100324991 [T/C] rs1348276 4 100325630 [A/C] rs1442490 4 100326403 [A/G] rs284792 4 100330309 [T/C] rs729147 4 100333267 [A/G] rs284787 4 100333556 [A/G] NM_001166504,NM_000673 ADH7,ADH7 EXON Silent,Silent rs3805331 4 100333932 [A/G] NM_001166504,NM_000673 ADH7,ADH7 EXON Silent,Silent rs4147553 4 100334943 [T/C] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs284785 4 100335586 [T/C] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs4147551 4 100335907 [T/C] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs1827567 4 100336102 [A/G] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs1154454 4 100338342 [A/G] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs1154456 4 100339596 [A/G] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs1154457 4 100339793 [T/C] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs17588761 4 100340563 [A/G] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs17529377 4 100340586 [T/C] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs2584465 4 100341075 [T/A] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs1154459 4 100341103 [A/G] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs930478 4 100341381 [A/G] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs1154460 4 100341643 [A/G] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs971074 4 100341861 [T/C] NM_001166504,NM_000673 ADH7,ADH7 EXON Synonymous_R238R,Synonymous_R230R rs12504511 4 100348872 [A/G] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs284797 4 100349135 [T/C] NM_001166504,NM_000673 ADH7,ADH7 EXON Missense_R140H,Missense_R132H rs4147550 4 100349168 [T/C] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs3737482 4 100349466 [T/C] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs4147549 4 100356012 [A/G] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs1154469 4 100356179 [T/C] NM_001166504,NM_000673 ADH7,ADH7 Silent,Silent rs17537595 4 100356466 [A/G] NM_000673 ADH7 EXON Silent rs2851028 4 100357018 [A/G] rs377582 4 100357546 [A/C] rs1154474 4 100360117 [T/C] rs1154476 4 100360727 [T/C] rs1154477 4 100361769 [A/G] rs1154480 4 100363569 [A/G] rs2119888 4 100380148 [A/G] rs2851024 4 100391104 [A/C] rs12505135 4 100392060 [A/G] rs1121886 4 100394210 [A/G] rs1442482 4 100399736 [T/C] rs1354367 4 100407388 [T/G] rs1032827 4 100423715 [T/C] rs2654838 4 100424345 [A/G] rs7669241 4 100430924 [A/G] rs2851025 4 100437553 [T/C] NM_032149 C4orf17 Silent rs1354368 4 100441886 [A/G] NM_032149 C4orf17 Silent rs13143848 4 100443720 [A/G] NM_032149 C4orf17 EXON Missense_G64E rs13119384 4 100443782 [T/C] NM_032149 C4orf17 EXON Missense_S85P rs17029087 4 100443800 [A/G] NM_032149 C4orf17 EXON Missense_E91K rs10021082 4 100444178 [T/C] NM_032149 C4orf17 Silent rs13126513 4 100444684 [T/C] NM_032149 C4orf17 Silent rs884275 4 100450712 [T/C] NM_032149 C4orf17 Silent rs10031512 4 100457841 [T/C] NM_032149 C4orf17 Silent rs1491235 4 100467879 [A/G] NM_001134666,NM_001134665,NM_152292 TRMT10A,TRMT10A,TRMT10A EXON Silent,Silent,Silent rs13135826 4 100472636 [A/G] NM_001134666,NM_001134665,NM_152292 TRMT10A,TRMT10A,TRMT10A Silent,Silent,Silent rs11935423 4 100477462 [T/C] NM_001134666,NM_001134665,NM_152292 TRMT10A,TRMT10A,TRMT10A Silent,Silent,Silent rs10026790 4 100484543 [A/G] NM_001134666,NM_001134665,NM_152292 TRMT10A,TRMT10A,TRMT10A EXON Silent,Silent,Silent rs11097669 4 100486295 [A/G] NM_000253,NM_001300785 MTTP,MTTP Silent,Silent rs12647527 4 100487712 [A/G] NM_000253,NM_001300785 MTTP,MTTP Silent,Silent rs1503777 4 100490438 [T/G] NM_000253,NM_001300785 MTTP,MTTP Silent,Silent rs1503778 4 100490688 [A/G] NM_000253,NM_001300785 MTTP,MTTP Silent,Silent rs11933337 4 100491772 [T/C] NM_000253,NM_001300785 MTTP,MTTP Silent,Silent rs1800804 4 100495817 [T/C] NM_000253,NM_001300785 MTTP,MTTP Silent,Silent rs2306986 4 100504575 [G/C] NM_000253,NM_001300785 MTTP,MTTP EXON Missense_E98D,Missense_E125D rs3816873 4 100504664 [T/C] NM_000253,NM_001300785 MTTP,MTTP EXON Missense_I128T,Missense_I155T rs17029173 4 100509321 [T/G] NM_000253,NM_001300785 MTTP,MTTP Silent,Silent rs991811 4 100510859 [T/C] NM_000253,NM_001300785 MTTP,MTTP EXON Synonymous_G151G,Synonymous_G178G rs982424 4 100512412 [T/C] NM_000253,NM_001300785 MTTP,MTTP EXON Synonymous_C174C,Synonymous_C201C rs17599091 4 100512919 [G/C] NM_000253,NM_001300785 MTTP,MTTP EXON Missense_Q244E,Missense_Q271E rs17029213 4 100518247 [A/C] NM_000253,NM_001300785 MTTP,MTTP EXON Synonymous_T311T,Synonymous_T338T rs17029215 4 100521805 [A/C] NM_000253,NM_001300785 MTTP,MTTP EXON Missense_D384A,Missense_D411A rs745075 4 100532637 [T/C] NM_000253,NM_001300785 MTTP,MTTP Silent,Silent rs1032355 4 100539896 [T/C] NM_000253,NM_001300785 MTTP,MTTP Silent,Silent rs881980 4 100543304 [T/G] NM_000253,NM_001300785 MTTP,MTTP Silent,Silent rs2255119 4 100543745 [A/G] NM_000253,NM_001300785 MTTP,MTTP Silent,Silent rs958868 4 100553223 [T/C] rs7659550 4 100554402 [T/G] rs12641768 4 100558594 [A/C] NM_001354435 C4orf54 EXON Silent rs17600719 4 100563999 [A/G] NM_001354435 C4orf54 Silent rs1491242 4 100571001 [T/C] NM_001354435 C4orf54 EXON Missense_Q1602R rs17029300 4 100580702 [A/G] rs7696714 4 100588306 [T/C] rs1027223 4 100613859 [A/G] rs10516451 4 100626549 [A/G] rs1388294 4 100633241 [T/C] rs1586757 4 100637756 [T/C] rs12648843 4 100638882 [T/C] rs13108707 4 100639912 [A/G] rs13123292 4 100642113 [A/G] rs13112253 4 100643484 [T/C] rs7670607 4 100646108 [T/C] rs13150420 4 100651270 [A/G] rs13116934 4 100658372 [A/C] rs1108961 4 100663166 [T/C] rs7666347 4 100666364 [T/C] rs11729480 4 100668696 [A/G] rs4699760 4 100671057 [T/C] rs1426730 4 100671124 [T/C] rs12649867 4 100673830 [A/G] rs1426736 4 100678905 [T/C] rs6849369 4 100682937 [T/C] rs6834229 4 100686270 [T/C] rs6831238 4 100705272 [T/C] rs2555482 4 100705602 [T/G] rs12152555 4 100712375 [T/C] rs13134954 4 100713621 [A/C] rs6846223 4 100728212 [T/C] rs1426738 4 100728698 [T/C] rs1365495 4 100734264 [A/G] rs4699763 4 100738894 [T/C] NM_014395,NM_001306151 DAPP1,DAPP1 Silent,Silent rs4699764 4 100740709 [A/C] NM_014395,NM_001306151 DAPP1,DAPP1 Silent,Silent rs3775499 4 100743145 [A/C] NM_014395,NM_001306151 DAPP1,DAPP1 Silent,Silent rs9994042 4 100743389 [T/C] NM_014395,NM_001306151 DAPP1,DAPP1 Silent,Silent rs3775500 4 100743513 [T/G] NM_014395,NM_001306151 DAPP1,DAPP1 Silent,Silent rs9307241 4 100747164 [T/C] NM_014395,NM_001306151 DAPP1,DAPP1 Silent,Silent rs1465518 4 100753527 [A/G] NM_014395,NM_001306151 DAPP1,DAPP1 Silent,Silent rs6813099 4 100755107 [T/C] NM_014395,NM_001306151 DAPP1,DAPP1 Silent,Silent rs17611664 4 100758557 [A/G] NM_014395,NM_001306151 DAPP1,DAPP1 Silent,Silent rs6848666 4 100770454 [T/C] NM_014395,NM_001306151 DAPP1,DAPP1 Silent,Silent rs6849599 4 100770696 [A/G] NM_014395,NM_001306151 DAPP1,DAPP1 Silent,Silent rs17029594 4 100771895 [T/C] NM_014395,NM_001306151 DAPP1,DAPP1 Silent,Silent rs4699767 4 100772603 [T/C] NM_014395,NM_001306151 DAPP1,DAPP1 Silent,Silent rs3737484 4 100784980 [T/C] NM_014395,NM_001306151 DAPP1,DAPP1 EXON Synonymous_F218F,Synonymous_F218F rs15924 4 100790307 [A/G] NM_014395,NM_001306151 DAPP1,DAPP1 EXON Silent,Silent rs6532834 4 100790328 [A/G] NM_014395,NM_001306151 DAPP1,DAPP1 EXON Silent,Silent rs17540668 4 100791163 [T/C] NM_014395,NM_001306151 DAPP1,DAPP1 EXON Silent,Silent rs11944405 4 100799961 [T/C] NR_024170,NM_021970,NM_001243736 LAMTOR3,LAMTOR3,LAMTOR3 EXON Silent,Silent,Silent rs11723286 4 100801273 [A/G] NR_024170,NM_021970,NM_001243736 LAMTOR3,LAMTOR3,LAMTOR3 EXON Silent,Silent,Silent rs13117491 4 100804704 [T/C] NR_024170,NM_021970,NM_001243736 LAMTOR3,LAMTOR3,LAMTOR3 Silent,Silent,Silent rs6532835 4 100805207 [A/C] NR_024170,NM_021970,NM_001243736 LAMTOR3,LAMTOR3,LAMTOR3 Silent,Silent,Silent rs10016741 4 100807221 [T/G] NR_024170,NM_021970,NM_001243736 LAMTOR3,LAMTOR3,LAMTOR3 Silent,Silent,Silent rs11937985 4 100808909 [T/C] NR_024170,NM_021970,NM_001243736 LAMTOR3,LAMTOR3,LAMTOR3 Silent,Silent,Silent rs11945303 4 100810611 [T/C] NR_024170,NM_021970,NM_001243736 LAMTOR3,LAMTOR3,LAMTOR3 Silent,Silent,Silent rs11931053 4 100823058 [A/G] NM_001031723,NM_001278310 DNAJB14,DNAJB14 Silent,Silent rs7676564 4 100829746 [T/C] NM_001031723,NM_001278310 DNAJB14,DNAJB14 Silent,Silent rs2114442 4 100832060 [T/C] NM_001031723,NM_001278310 DNAJB14,DNAJB14 Silent,Silent rs17029662 4 100847105 [A/G] NM_001031723,NM_001278310,NM_001278311 DNAJB14,DNAJB14,DNAJB14 Silent,Silent,Silent rs10516458 4 100848810 [A/G] NM_001031723,NM_001278310,NM_001278311 DNAJB14,DNAJB14,DNAJB14 Silent,Silent,Silent rs10516459 4 100848952 [T/C] NM_001031723,NM_001278310,NM_001278311 DNAJB14,DNAJB14,DNAJB14 Silent,Silent,Silent rs11097681 4 100852921 [A/G] NM_001031723,NM_001278310,NM_001278311 DNAJB14,DNAJB14,DNAJB14 Silent,Silent,Silent rs17029673 4 100872365 [A/G] NR_125923 LOC256880 Silent rs2070738 4 100873826 [T/C] NR_125923 LOC256880 Silent rs11736218 4 100876648 [T/C] NR_125923 LOC256880 Silent rs28561548 4 100880420 [A/G] NR_125923 LOC256880 Silent rs17029696 4 100916785 [T/G] NR_125923 LOC256880 Silent rs2866180 4 100945695 [T/C] NR_125923 LOC256880 Silent rs13136235 4 100971095 [T/G] rs4699769 4 100979170 [A/G] rs7340886 4 101006705 [T/C] rs4699773 4 101016395 [T/C] rs11735694 4 101026248 [T/C] rs4602501 4 101046193 [A/C] rs6855061 4 101055012 [A/G] rs11097688 4 101057346 [A/G] rs2866185 4 101072734 [T/G] rs7654712 4 101082077 [T/C] rs6817883 4 101082943 [T/C] rs6854962 4 101085258 [T/C] rs6532846 4 101094284 [A/G] rs2866194 4 101100658 [A/G] rs2866197 4 101106316 [T/C] rs1063821 4 101107276 [A/C] NM_145244 DDIT4L EXON Silent rs3819183 4 101107476 [A/G] NM_145244 DDIT4L EXON Silent rs11734827 4 101108008 [A/C] NM_145244 DDIT4L EXON Silent rs11726613 4 101108057 [A/C] NM_145244 DDIT4L EXON Silent rs11734833 4 101108069 [A/G] NM_145244 DDIT4L EXON Silent rs11726694 4 101108132 [A/G] NM_145244 DDIT4L EXON Silent rs11726650 4 101108191 [T/C] NM_145244 DDIT4L EXON Silent rs10007201 4 101108332 [T/C] NM_145244 DDIT4L EXON Silent rs17029785 4 101114549 [T/C] NR_125924 LOC101929353 Silent rs3737483 4 101114999 [T/C] NR_125924 LOC101929353 EXON Silent rs10033894 4 101118465 [T/C] NR_125924 LOC101929353 Silent rs6849832 4 101120472 [T/C] NR_125924 LOC101929353 Silent rs10030715 4 101126405 [T/C] NR_125924 LOC101929353 Silent rs868911 4 101128211 [A/G] NR_125924 LOC101929353 Silent rs7699773 4 101131209 [A/G] NR_125924 LOC101929353 Silent rs2866209 4 101131793 [T/C] NR_125924 LOC101929353 Silent rs12506292 4 101132253 [T/C] NR_125924 LOC101929353 Silent rs4352484 4 101133509 [A/G] NR_125924 LOC101929353 Silent rs4396998 4 101135216 [T/C] NR_125924 LOC101929353 Silent rs11097701 4 101135989 [A/G] NR_125924 LOC101929353 Silent rs10001464 4 101137084 [T/C] rs6820091 4 101137500 [A/G] rs13103925 4 101140986 [T/C] rs4440226 4 101153391 [T/C] rs6825670 4 101168332 [A/G] rs4557267 4 101170196 [A/G] rs11734053 4 101176062 [T/C] rs4699395 4 101179982 [T/C] rs4235448 4 101191677 [T/C] rs4699786 4 101193982 [T/C] rs10026337 4 101197518 [A/C] rs4235450 4 101210715 [T/C] rs6836741 4 101213802 [T/G] rs4128643 4 101214573 [A/G] rs4130108 4 101216854 [A/G] rs7659715 4 101219932 [A/G] rs10000959 4 101222442 [T/C] rs4306962 4 101228493 [A/G] rs4235455 4 101229453 [T/C] rs4437263 4 101232970 [T/C] rs11945180 4 101238386 [A/C] rs11934689 4 101250176 [A/G] rs11097709 4 101251778 [T/C] rs7696248 4 101260798 [A/G] rs4478196 4 101262840 [A/G] rs12645427 4 101275774 [A/G] rs4458459 4 101283279 [T/C] rs12647890 4 101299450 [T/C] rs1982086 4 101306586 [T/C] rs13122464 4 101306906 [A/G] rs10516462 4 101307674 [A/G] rs1019947 4 101310665 [T/C] rs6828453 4 101313277 [T/C] rs1368525 4 101315884 [T/C] rs3733434 4 101318048 [A/G] NM_001159694,NM_016242 EMCN,EMCN EXON Silent,Silent rs4071 4 101319165 [T/C] NM_001159694,NM_016242 EMCN,EMCN EXON Silent,Silent rs17552409 4 101319332 [A/G] NM_001159694,NM_016242 EMCN,EMCN EXON Silent,Silent rs2116992 4 101320412 [T/C] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs1056659 4 101321764 [T/C] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs17552895 4 101330587 [A/G] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs3822069 4 101333993 [A/C] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs3733436 4 101338027 [A/C] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs3733437 4 101338217 [T/C] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs1347197 4 101341678 [A/C] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs17030120 4 101342606 [A/C] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs1392887 4 101342922 [T/G] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs7674306 4 101348412 [T/G] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs357652 4 101353122 [A/G] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs1501075 4 101368154 [T/G] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs242596 4 101383092 [T/C] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs11097720 4 101388148 [A/G] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs924531 4 101398205 [T/G] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs992834 4 101402501 [T/C] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs1587549 4 101423326 [A/G] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs3775367 4 101432085 [A/G] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs1501096 4 101432849 [T/G] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs1318710 4 101436201 [A/G] NM_001159694,NM_016242 EMCN,EMCN Silent,Silent rs1501089 4 101442540 [T/C] rs2036357 4 101443803 [A/G] rs357670 4 101452208 [A/G] rs1846870 4 101454173 [T/G] rs1392874 4 101466820 [A/C] rs977668 4 101470231 [A/C] rs2567398 4 101471756 [A/C] rs10021695 4 101475765 [T/C] rs2013390 4 101479155 [T/C] rs2651581 4 101486889 [T/C] rs17030274 4 101488171 [T/C] rs11936939 4 101494460 [T/C] rs1827303 4 101494857 [T/C] rs2567388 4 101501761 [T/G] rs6848407 4 101503277 [A/C] rs2651555 4 101503451 [A/G] rs17030283 4 101505168 [A/T] rs2651562 4 101506795 [T/C] rs13148793 4 101507299 [T/C] rs2651569 4 101508622 [T/C] rs2567376 4 101508995 [T/G] rs1501104 4 101510054 [T/C] rs6830402 4 101510537 [A/G] rs2567373 4 101511108 [A/G] rs6857393 4 101514587 [A/G] rs9999569 4 101514782 [T/G] rs7671093 4 101515453 [A/G] rs2866217 4 101523312 [A/G] rs2866223 4 101525948 [A/G] rs2866224 4 101528207 [A/G] rs12641140 4 101534643 [T/C] rs7658792 4 101551216 [A/G] rs10025419 4 101568956 [A/G] rs9759759 4 101573688 [A/C] rs13118526 4 101579340 [A/C] rs4586953 4 101579972 [T/G] rs13131732 4 101586719 [A/G] NR_046811 LINC01216 Silent rs7693246 4 101595019 [T/C] NR_046811 LINC01216 Silent rs10516468 4 101599908 [T/C] rs10030146 4 101616281 [A/G] rs925169 4 101619817 [A/G] rs7691456 4 101627782 [T/C] rs7667413 4 101627867 [A/G] rs1396287 4 101634693 [A/G] rs10008030 4 101640802 [A/G] rs9995730 4 101644204 [A/G] rs981272 4 101651113 [T/C] rs17572230 4 101651209 [A/G] rs981271 4 101651417 [A/G] rs1508421 4 101683999 [T/G] rs6839885 4 101698883 [T/C] rs2089540 4 101699382 [A/G] rs10010623 4 101712104 [A/G] rs12507027 4 101713756 [A/G] rs6853889 4 101714921 [A/G] rs4699824 4 101722485 [A/G] rs1567282 4 101725061 [A/G] rs10008442 4 101728821 [A/G] rs13130138 4 101742816 [T/G] rs6419156 4 101748186 [A/G] rs13104901 4 101751619 [T/G] rs17030500 4 101766650 [T/C] rs6847657 4 101774201 [A/G] rs6841123 4 101796290 [A/G] rs11725047 4 101798797 [A/C] rs4699162 4 101799187 [A/C] rs978155 4 101800766 [T/C] rs12646623 4 101804019 [A/C] rs6851921 4 101845129 [A/G] rs13121097 4 101851136 [A/G] rs10001585 4 101851511 [A/G] rs7677774 4 101854977 [A/G] rs17826594 4 101855402 [A/G] rs4698838 4 101858763 [T/C] rs4698981 4 101867277 [A/G] rs17030661 4 101868169 [T/C] rs4626209 4 101868917 [T/C] rs979665 4 101881356 [A/G] rs2645370 4 101886921 [T/C] rs12649554 4 101896676 [T/C] rs2645373 4 101904475 [A/G] rs4699014 4 101906493 [A/G] rs2851045 4 101920450 [T/C] rs2851048 4 101924060 [T/C] rs11941029 4 101929135 [T/C] rs2851057 4 101933417 [T/G] rs10000538 4 101942483 [T/C] rs6826912 4 101945139 [T/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA EXON Silent,Silent,Silent rs1042094 4 101946948 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA EXON Silent,Silent,Silent rs1880942 4 101953182 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2851060 4 101953322 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2037773 4 101958617 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs10025768 4 101965295 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2178006 4 101970512 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs1358312 4 101971451 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs6851231 4 101983607 [T/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs10020845 4 101989580 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs17030739 4 101996812 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs4146577 4 102001692 [T/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA EXON Missense_K318Q,Missense_K318Q,Missense_K318Q rs3804357 4 102002123 [A/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs17030741 4 102010038 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs17030746 4 102016486 [A/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs17030753 4 102021290 [A/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs17030758 4 102026137 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2732510 4 102031775 [A/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2732512 4 102033997 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs12639641 4 102040091 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs6820738 4 102041236 [T/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs17829566 4 102042049 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs17030795 4 102048076 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2732514 4 102058842 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2732518 4 102061730 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs10516472 4 102065589 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs17829885 4 102071671 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs1405688 4 102074134 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2063058 4 102076982 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs1527351 4 102084331 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs13142024 4 102089849 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs7677550 4 102090477 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs10516471 4 102092995 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs13118966 4 102093433 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2659501 4 102093807 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs4699110 4 102094453 [T/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2850979 4 102094764 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2659504 4 102095497 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs17030887 4 102098066 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs10050301 4 102103046 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs11935869 4 102115044 [T/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs1395475 4 102115186 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs13112866 4 102120454 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2850992 4 102122755 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2135611 4 102131300 [T/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs978373 4 102154344 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2850950 4 102158450 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs17030994 4 102165917 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs3804406 4 102166581 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs3804408 4 102167216 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2850373 4 102168234 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2583405 4 102172981 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2850962 4 102176098 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2850969 4 102183594 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs1561720 4 102192342 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs13116679 4 102199215 [A/G] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs11943655 4 102211124 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2850355 4 102211222 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2850369 4 102232985 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs2583399 4 102236914 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs6532924 4 102239170 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs17031191 4 102261268 [T/C] NM_000944,NM_001130691,NM_001130692 PPP3CA,PPP3CA,PPP3CA Silent,Silent,Silent rs6845263 4 102276682 [T/C] rs13135111 4 102301819 [A/C] rs2165503 4 102303145 [A/G] rs10015209 4 102323959 [T/C] rs17031254 4 102325626 [T/G] rs2044044 4 102333865 [A/G] rs990960 4 102353934 [A/G] rs4398526 4 102382498 [A/C] rs6855746 4 102387446 [A/G] rs17031304 4 102395086 [A/G] rs9307257 4 102396292 [A/G] rs6846469 4 102398446 [A/G] rs6532939 4 102399209 [A/G] rs1863575 4 102407109 [A/G] rs11943435 4 102416308 [T/C] rs6825984 4 102427214 [T/C] rs890448 4 102432702 [T/C] rs1426538 4 102449905 [A/G] rs13434873 4 102451022 [T/C] rs10022442 4 102470700 [T/G] rs6838771 4 102475025 [T/G] rs17031441 4 102484972 [T/C] rs2723054 4 102492986 [A/G] rs6842043 4 102508776 [T/G] rs2723058 4 102508948 [T/C] rs2615973 4 102515133 [T/G] rs2717833 4 102520862 [T/G] rs7661775 4 102525045 [A/G] rs11930552 4 102526313 [A/G] rs17031472 4 102545130 [T/G] rs12643950 4 102548422 [A/G] rs17031503 4 102551731 [T/C] rs7666463 4 102560877 [A/G] rs4699246 4 102563794 [A/G] rs7663310 4 102565480 [A/C] rs10007495 4 102566525 [A/C] rs2016504 4 102566810 [T/C] rs2866627 4 102569368 [T/C] rs1009257 4 102569411 [A/G] rs10009721 4 102570449 [T/C] rs17250305 4 102570753 [A/C] rs7681723 4 102571890 [T/C] rs7682523 4 102572251 [T/C] rs7676236 4 102574367 [A/G] rs2866422 4 102603328 [A/C] rs7669395 4 102606843 [A/G] rs17251102 4 102608288 [A/G] rs12644085 4 102613885 [A/G] rs7669524 4 102614169 [A/G] rs11723683 4 102616166 [A/G] rs13149930 4 102624280 [T/C] rs17252142 4 102634710 [T/C] rs768290 4 102635952 [A/G] rs12512546 4 102638137 [T/C] rs2866430 4 102638201 [A/G] rs10011961 4 102641428 [T/C] rs12501586 4 102642012 [T/C] rs12506517 4 102642526 [T/C] rs13103794 4 102656452 [T/C] rs10516481 4 102658991 [T/C] rs6818863 4 102665975 [A/G] rs7675129 4 102675023 [T/C] rs6815355 4 102677450 [A/G] rs871061 4 102679337 [A/C] rs4632664 4 102692665 [A/G] rs10003889 4 102696219 [A/G] rs7695738 4 102701232 [A/G] rs7695470 4 102701262 [T/C] rs4371620 4 102708235 [T/C] rs7375516 4 102709119 [T/C] rs10031210 4 102714886 [A/G] NM_017935,NM_001127507 BANK1,BANK1 Silent,Silent rs11944613 4 102718795 [A/G] NM_017935,NM_001127507 BANK1,BANK1 Silent,Silent rs13146194 4 102723640 [T/C] NM_017935,NM_001127507 BANK1,BANK1 Silent,Silent rs4699262 4 102726005 [A/G] NM_017935,NM_001127507 BANK1,BANK1 Silent,Silent rs6833249 4 102726073 [A/G] NM_017935,NM_001127507 BANK1,BANK1 Silent,Silent rs13136297 4 102736456 [T/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs10028805 4 102737250 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs1421627 4 102739536 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs4276281 4 102746780 [A/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs4637409 4 102753408 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs17031708 4 102764358 [T/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs1421624 4 102774964 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs6849308 4 102776083 [T/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs17031717 4 102780288 [T/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs4572884 4 102783351 [T/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs13101528 4 102786685 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs12331846 4 102790613 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs12331849 4 102790818 [T/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs10516484 4 102792085 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs17031755 4 102792354 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs17031758 4 102792983 [T/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs11934097 4 102818067 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs12505747 4 102821381 [T/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs6532979 4 102834387 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs6812874 4 102839008 [T/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs3733197 4 102839287 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 EXON Missense_A383T,Missense_A250T,Missense_A353T rs10014485 4 102839879 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs13119516 4 102841605 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs2631255 4 102849920 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs17208914 4 102854390 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs2112139 4 102883425 [T/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs2850374 4 102893323 [T/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs2631273 4 102899504 [T/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs1027013 4 102904490 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs2851320 4 102909994 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs2850377 4 102912159 [T/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs2631271 4 102914396 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs6532982 4 102927310 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs6844449 4 102936592 [T/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs17031862 4 102936972 [T/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs2850390 4 102943996 [A/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs17853030 4 102946392 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 EXON Synonymous_R440R,Synonymous_R307R,Synonymous_R410R rs2631267 4 102948472 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs2631268 4 102948730 [T/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs7685012 4 102948991 [T/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs1872701 4 102953681 [T/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs3113676 4 102965043 [T/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 EXON Missense_C650R,Missense_C517R,Missense_C620R rs2850395 4 102968082 [T/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs2658534 4 102970332 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs17211702 4 102977140 [T/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs17031983 4 102979904 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs17031987 4 102980397 [T/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs4550926 4 102983720 [T/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs4698987 4 102988188 [A/C] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 Silent,Silent,Silent rs6842661 4 102995263 [A/G] NM_017935,NM_001127507,NM_001083907 BANK1,BANK1,BANK1 EXON Silent,Silent,Silent rs7675363 4 102998867 [T/C] rs6843917 4 103003758 [T/C] rs6856488 4 103008712 [T/C] rs6532990 4 103013903 [T/C] rs238487 4 103021348 [T/C] rs17032037 4 103023170 [A/G] rs238490 4 103023963 [A/C] rs238495 4 103053192 [A/G] rs236755 4 103058514 [T/C] rs151476 4 103075330 [T/G] rs236780 4 103084840 [T/C] rs17032126 4 103088491 [A/G] rs17222149 4 103091187 [A/G] rs13131758 4 103091829 [A/G] rs11727065 4 103098004 [A/G] rs190223 4 103105685 [A/C] rs1573494 4 103106466 [A/G] rs439538 4 103107786 [T/C] rs238449 4 103112813 [A/C] rs451461 4 103113866 [T/C] rs7665350 4 103115022 [A/G] rs6419158 4 103117289 [A/C] rs151382 4 103117826 [T/C] rs151378 4 103121043 [A/G] rs151377 4 103121726 [A/G] rs151375 4 103122348 [T/C] rs1440235 4 103125285 [A/G] rs11735227 4 103125383 [A/G] rs7667281 4 103133044 [T/C] rs151417 4 103135867 [A/G] rs17032168 4 103137577 [A/G] rs1540052 4 103137977 [A/G] rs142493 4 103144754 [T/C] rs10010108 4 103151461 [A/G] rs13126885 4 103173749 [T/C] NM_001135147 SLC39A8 EXON Silent rs151369 4 103176770 [T/C] NM_001135147 SLC39A8 Silent rs2298752 4 103177071 [A/G] NM_001135147 SLC39A8 Silent rs170871 4 103180149 [T/C] NM_001135147 SLC39A8 Silent rs9331 4 103183218 [A/G] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 EXON Silent,Silent,Silent,Silent rs151390 4 103183510 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 EXON Silent,Silent,Silent,Silent rs9705 4 103183531 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 EXON Silent,Silent,Silent,Silent rs151392 4 103183935 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 EXON Silent,Silent,Silent,Silent rs1045155 4 103184064 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 EXON Silent,Silent,Silent,Silent rs13107325 4 103188709 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 EXON Missense_A391T,Missense_A324T,Missense_A391T,Missense_A391T rs17823966 4 103189036 [A/G] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 EXON Synonymous_H347H,Synonymous_H280H,Synonymous_H347H,Synonymous_H347H rs151401 4 103190128 [A/G] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs17032400 4 103190229 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs151402 4 103190486 [A/G] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs10014145 4 103200577 [A/G] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs2165265 4 103203500 [T/G] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs233821 4 103204358 [A/G] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs233818 4 103204734 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs448195 4 103205126 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs17226148 4 103205668 [A/G] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs17824524 4 103206152 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs233805 4 103212864 [T/G] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs4698844 4 103217980 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs7699390 4 103218446 [A/G] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs170869 4 103220401 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs7664423 4 103223504 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs971752 4 103224534 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs6829701 4 103227073 [A/G] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs13103835 4 103232168 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs17278473 4 103243101 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs998719 4 103244676 [T/C] NM_001135147,NM_001135148,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent,Silent rs7664683 4 103255692 [T/C] NM_001135147,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent rs17212693 4 103258848 [A/G] NM_001135147,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent rs1462943 4 103265343 [A/C] NM_001135147,NM_001135146,NM_022154 SLC39A8,SLC39A8,SLC39A8 Silent,Silent,Silent rs11931217 4 103271888 [A/C] rs13152048 4 103275840 [A/C] rs10516494 4 103285705 [A/G] rs4394001 4 103306670 [T/G] rs6843751 4 103308071 [T/C] rs962399 4 103308907 [A/G] rs1381897 4 103324850 [A/G] rs12508086 4 103327149 [T/C] rs10856967 4 103327536 [T/C] rs1381894 4 103333139 [T/C] rs12510124 4 103337685 [A/G] rs12513242 4 103340510 [A/G] NR_136202 LOC105377621 EXON Silent rs9996947 4 103343133 [A/G] NR_136202 LOC105377621 Silent rs964504 4 103349049 [T/G] NR_136202 LOC105377621 Silent rs6533014 4 103349740 [A/G] NR_136202 LOC105377621 Silent rs6846971 4 103359744 [T/C] NR_136202 LOC105377621 Silent rs926163 4 103364762 [T/C] NR_136202 LOC105377621 Silent rs13115343 4 103365532 [T/G] NR_136202 LOC105377621 Silent rs10031415 4 103369480 [A/G] NR_136202 LOC105377621 Silent rs17032641 4 103370889 [T/C] NR_136202 LOC105377621 Silent rs13116385 4 103373286 [A/G] NR_136202 LOC105377621 Silent rs10000030 4 103374154 [A/G] NR_136202 LOC105377621 Silent rs1313924 4 103375303 [A/C] NR_136202 LOC105377621 Silent rs1585607 4 103376474 [T/C] NR_136202 LOC105377621 Silent rs1313925 4 103377576 [T/C] NR_136202 LOC105377621 Silent rs1314336 4 103378866 [T/C] NR_136202 LOC105377621 Silent rs230490 4 103387419 [A/G] NR_136202 LOC105377621 Silent rs230489 4 103388441 [T/C] NR_136202 LOC105377621 Silent rs230487 4 103389409 [A/C] NR_136202 LOC105377621 Silent rs2903281 4 103396333 [A/G] NR_136202 LOC105377621 Silent rs2085548 4 103397014 [T/C] NR_136202 LOC105377621 Silent rs3774934 4 103427476 [A/G] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 Silent,Silent,Silent rs17032705 4 103432974 [A/G] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 Silent,Silent,Silent rs1599961 4 103443569 [A/G] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 Silent,Silent,Silent rs1598856 4 103446115 [A/G] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 Silent,Silent,Silent rs230535 4 103448582 [A/C] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 Silent,Silent,Silent rs4647992 4 103455347 [T/C] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 Silent,Silent,Silent rs118882 4 103463007 [T/C] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 Silent,Silent,Silent rs13117745 4 103478703 [T/C] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 Silent,Silent,Silent rs4648016 4 103489670 [T/C] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 Silent,Silent,Silent rs4648039 4 103505961 [T/C] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 EXON Synonymous_Y350Y,Synonymous_Y349Y,Synonymous_Y349Y rs1020759 4 103510511 [T/C] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 Silent,Silent,Silent rs10489114 4 103511388 [T/C] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 Silent,Silent,Silent rs4648072 4 103518700 [A/G] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 EXON Missense_M507V,Missense_M506V,Missense_M506V rs4648086 4 103522150 [A/G] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 EXON Missense_R579K,Missense_R578K,Missense_R578K rs4648090 4 103527068 [A/G] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 Silent,Silent,Silent rs4648093 4 103527655 [A/G] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 EXON Synonymous_T585T,Synonymous_T584T,Synonymous_T584T rs4648135 4 103536670 [A/G] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 Silent,Silent,Silent rs1609798 4 103537442 [T/C] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 Silent,Silent,Silent rs4648143 4 103537774 [A/G] NM_003998,NM_001165412,NM_001319226 NFKB1,NFKB1,NFKB1 EXON Silent,Silent,Silent rs997476 4 103542005 [T/G] rs10489113 4 103542201 [T/C] rs11733293 4 103545253 [T/C] rs10213251 4 103549149 [T/C] rs1054037 4 103552709 [T/C] NM_005908 MANBA EXON Silent rs4013 4 103552813 [T/C] NM_005908 MANBA EXON Silent rs7672268 4 103552858 [T/C] NM_005908 MANBA EXON Silent rs1054029 4 103553053 [A/G] NM_005908 MANBA EXON Silent rs2272697 4 103555992 [A/G] NM_005908 MANBA EXON Synonymous_L790L rs2866413 4 103557077 [A/G] NM_005908 MANBA EXON Missense_T701M rs6833962 4 103558731 [T/C] NM_005908 MANBA Silent rs228614 4 103578637 [A/G] NM_005908 MANBA Silent rs17033150 4 103601214 [T/C] NM_005908 MANBA Silent rs227284 4 103607635 [A/G] NM_005908 MANBA Silent rs17033168 4 103611771 [T/C] NM_005908 MANBA EXON Synonymous_L277L rs227368 4 103611845 [T/C] NM_005908 MANBA EXON Missense_V253I rs227375 4 103618023 [T/C] NM_005908 MANBA Silent rs10000705 4 103624238 [T/G] NM_005908 MANBA Silent rs17033210 4 103639840 [A/G] NM_005908 MANBA Silent rs223502 4 103640758 [T/C] NM_005908 MANBA Silent rs6857760 4 103645082 [T/C] NM_005908 MANBA EXON Synonymous_T105T rs7677366 4 103646941 [A/C] NM_005908 MANBA Silent rs223500 4 103647047 [T/C] NM_005908 MANBA Silent rs223498 4 103651962 [A/C] NM_005908 MANBA Silent rs6811212 4 103662776 [A/G] NM_005908 MANBA Silent rs223490 4 103679117 [T/G] NM_005908 MANBA Silent rs223489 4 103680984 [A/G] NM_005908 MANBA Silent rs223482 4 103687208 [A/G] rs11936434 4 103715820 [A/C] NR_125932,NM_001300795,NM_181893,NM_181886,NM_181891,NM_003340,NM_181892,NM_181889,NM_181887,NM_181890,NM_181888 LOC102723704,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12499161 4 103718319 [A/T] NR_125932,NM_001300795,NM_181893,NM_181886,NM_181891,NM_003340,NM_181892,NM_181889,NM_181887,NM_181890,NM_181888 LOC102723704,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs223418 4 103730493 [T/G] NM_001300795,NM_181893,NM_181886,NM_181891,NM_003340,NM_181892,NM_181889,NM_181887,NM_181890,NM_181888 UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs223412 4 103733600 [T/C] NM_001300795,NM_181893,NM_181886,NM_181891,NM_003340,NM_181892,NM_181889,NM_181887,NM_181890,NM_181888 UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10005010 4 103734219 [T/C] NM_001300795,NM_181893,NM_181886,NM_181891,NM_003340,NM_181892,NM_181889,NM_181887,NM_181890,NM_181888 UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3774997 4 103746753 [T/C] NM_001300795,NM_181893,NM_181886,NM_181891,NM_003340,NM_181892,NM_181889,NM_181887,NM_181890,NM_181888 UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs223391 4 103748224 [A/G] NM_181893,NM_181886,NM_181891,NM_003340,NM_181892,NM_181889,NM_181887,NM_181890,NM_181888 UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3,UBE2D3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs223374 4 103758301 [T/C] NM_181893,NM_181890,NR_131186,NR_131185 UBE2D3,UBE2D3,LOC105377348,LOC105377348 Silent,Silent,Silent,Silent rs223366 4 103765156 [A/G] NM_181893,NM_181890,NR_131186,NR_131185 UBE2D3,UBE2D3,LOC105377348,LOC105377348 EXON Silent,Silent,Silent,Silent rs223353 4 103775704 [T/C] NM_181893,NM_181890 UBE2D3,UBE2D3 Silent,Silent rs223340 4 103785051 [A/G] NM_181893,NM_181890 UBE2D3,UBE2D3 Silent,Silent rs223334 4 103788211 [A/G] NM_181893,NM_181890 UBE2D3,UBE2D3 Silent,Silent rs2198199 4 103789782 [A/G] NM_181893,NM_181890 UBE2D3,UBE2D3 Silent,Silent rs223315 4 103805443 [T/C] NM_001008388 CISD2 Silent rs223313 4 103807720 [T/C] NM_001008388,NR_047515,NR_047513,NM_001100874 CISD2,SLC9B1,SLC9B1,SLC9B1 Silent,Silent,Silent,Silent rs6419160 4 103859805 [A/G] NR_047515,NR_047513,NM_001100874,NM_139173 SLC9B1,SLC9B1,SLC9B1,SLC9B1 Silent,Silent,Silent,Silent rs4383620 4 103862854 [A/G] NR_047515,NR_047513,NM_001100874,NM_139173 SLC9B1,SLC9B1,SLC9B1,SLC9B1 Silent,Silent,Silent,Silent rs13137892 4 103870091 [A/G] NR_047515,NR_047513,NM_001100874,NM_139173 SLC9B1,SLC9B1,SLC9B1,SLC9B1 Silent,Silent,Silent,Silent rs9994654 4 103919065 [A/C] NR_047515,NR_047513,NM_001100874,NM_139173 SLC9B1,SLC9B1,SLC9B1,SLC9B1 Silent,Silent,Silent,Silent rs13133907 4 103922109 [A/G] NR_047515,NR_047513,NM_001100874,NM_139173 SLC9B1,SLC9B1,SLC9B1,SLC9B1 Silent,Silent,Silent,Silent rs6843738 4 103936001 [A/G] NR_047515,NR_047513,NM_001100874,NM_139173 SLC9B1,SLC9B1,SLC9B1,SLC9B1 Silent,Silent,Silent,Silent rs28445579 4 103937595 [A/G] NR_047515,NR_047513,NM_001100874,NM_139173 SLC9B1,SLC9B1,SLC9B1,SLC9B1 Silent,Silent,Silent,Silent rs7676765 4 103937933 [T/C] NR_047515,NR_047513,NM_001100874,NM_139173 SLC9B1,SLC9B1,SLC9B1,SLC9B1 Silent,Silent,Silent,Silent rs7698608 4 103937974 [A/C] NR_047515,NR_047513,NM_001100874,NM_139173 SLC9B1,SLC9B1,SLC9B1,SLC9B1 Silent,Silent,Silent,Silent rs12507225 4 103939894 [T/C] NR_047515,NR_047513,NM_001100874,NM_139173 SLC9B1,SLC9B1,SLC9B1,SLC9B1 Silent,Silent,Silent,Silent rs2623061 4 103940740 [A/G] NR_047515,NR_047513,NM_001100874,NM_139173 SLC9B1,SLC9B1,SLC9B1,SLC9B1 Silent,Silent,Silent,Silent rs10516496 4 103942165 [T/C] rs13150953 4 103942498 [A/G] rs10516497 4 103942714 [A/C] rs11946020 4 103944742 [T/C] rs12509294 4 103947466 [T/C] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 EXON Silent,Silent,Silent rs7668749 4 103949416 [T/C] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs1080081 4 103950425 [T/C] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs4699049 4 103951624 [T/C] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs34475639 4 103954851 [T/C] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs13130741 4 103956956 [T/C] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs7662527 4 103957595 [A/G] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs17033405 4 103960660 [T/C] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs7660298 4 103960768 [T/C] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs7694724 4 103962532 [A/G] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs2276976 4 103964529 [A/C] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 EXON Missense_F300C,Missense_F300C,Missense_F357C rs7679465 4 103965320 [T/C] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs11722396 4 103966589 [T/G] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs7672710 4 103971506 [A/G] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 EXON Missense_I102T,Missense_I102T,Missense_I159T rs13113099 4 103974122 [A/G] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs5008412 4 103975508 [T/C] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs6821545 4 103975725 [T/C] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs13149311 4 103977700 [T/C] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs12640820 4 103979497 [A/G] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs4698877 4 103981047 [A/G] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs7691873 4 103987899 [T/C] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs7687554 4 103991002 [A/G] NM_001300754,NM_001300756,NM_178833 SLC9B2,SLC9B2,SLC9B2 Silent,Silent,Silent rs7666067 4 104000498 [T/C] NM_020139 BDH2 EXON Silent rs12503399 4 104000853 [T/C] NM_020139 BDH2 EXON Silent rs12508269 4 104000922 [T/C] NM_020139 BDH2 Silent rs3796983 4 104001975 [A/C] NM_020139 BDH2 Silent rs2306478 4 104003148 [T/C] NM_020139 BDH2 Silent rs3775972 4 104004362 [T/C] NM_020139 BDH2 Silent rs7684344 4 104006315 [T/C] NM_020139 BDH2 Silent rs6825519 4 104007105 [T/C] NM_020139 BDH2 Silent rs7675057 4 104007996 [T/C] NM_020139 BDH2 Silent rs10516498 4 104010027 [T/C] NM_020139 BDH2 Silent rs746829 4 104011067 [A/G] NM_020139 BDH2 Silent rs7690059 4 104014114 [T/C] NM_020139 BDH2 Silent rs6831995 4 104017045 [T/C] NM_020139 BDH2 Silent rs6858419 4 104017305 [T/C] NM_020139 BDH2 Silent rs11933907 4 104021633 [A/G] rs2720447 4 104026547 [T/C] rs2623064 4 104030792 [A/C] NM_001813,NM_001286734 CENPE,CENPE Silent,Silent rs2711896 4 104031440 [T/G] NM_001813,NM_001286734 CENPE,CENPE Silent,Silent rs2720460 4 104054686 [A/G] NM_001813,NM_001286734 CENPE,CENPE Silent,Silent rs2243682 4 104059542 [A/G] NM_001813,NM_001286734 CENPE,CENPE EXON Missense_T2090M,Missense_T1969M rs2306106 4 104061551 [T/G] NM_001813,NM_001286734 CENPE,CENPE EXON Missense_E1925D,Missense_E1900D rs2615542 4 104066461 [A/G] NM_001813,NM_001286734 CENPE,CENPE EXON Missense_F1535L,Missense_F1510L rs11724309 4 104098605 [A/G] NM_001813,NM_001286734 CENPE,CENPE Silent,Silent rs2290943 4 104117191 [A/G] NM_001813,NM_001286734 CENPE,CENPE EXON Synonymous_T81T,Synonymous_T81T rs6850461 4 104120041 [T/C] rs17217592 4 104120119 [T/C] rs6815702 4 104127786 [A/G] rs6821646 4 104128452 [T/G] rs6533059 4 104133376 [T/G] rs35199266 4 104134846 [A/G] rs4699052 4 104137790 [T/C] rs7660968 4 104139904 [T/C] rs1580278 4 104140848 [A/C] rs7676474 4 104165717 [A/G] rs17033496 4 104179569 [T/C] rs11723084 4 104185435 [A/G] rs7656832 4 104194329 [T/C] rs7687989 4 104204409 [T/C] rs10516502 4 104214616 [A/G] rs6820979 4 104216086 [T/C] rs1607094 4 104225413 [A/G] rs1996350 4 104229547 [A/G] rs17219677 4 104235380 [T/C] rs11931910 4 104238041 [T/C] rs10213404 4 104240255 [A/C] rs6533083 4 104241267 [A/G] rs6836157 4 104242990 [A/G] rs7682050 4 104245131 [T/C] rs1996346 4 104250324 [A/G] rs6827135 4 104254217 [A/G] rs4699068 4 104257925 [A/G] rs7662107 4 104258396 [T/C] rs17285814 4 104260725 [A/G] rs10856971 4 104270805 [A/C] rs12649701 4 104271269 [A/G] rs17286262 4 104275452 [T/C] rs13101586 4 104282146 [T/C] rs11734572 4 104288620 [A/G] rs10009242 4 104293598 [T/C] rs6533086 4 104294789 [T/C] rs13111985 4 104308097 [A/G] rs6828829 4 104335667 [A/G] rs1289305 4 104353539 [T/C] NR_125925 LINC02428 Silent rs17221044 4 104372029 [T/C] rs10026360 4 104374596 [T/C] rs10019748 4 104381449 [T/C] rs340479 4 104382243 [A/G] rs17033669 4 104385495 [T/G] rs10011202 4 104396376 [A/G] rs437156 4 104401567 [A/G] rs7694802 4 104402247 [T/C] rs17033694 4 104403357 [A/C] rs17221890 4 104413137 [A/G] rs420934 4 104414511 [A/G] rs402681 4 104414948 [T/C] rs17033731 4 104416398 [A/G] rs340468 4 104418239 [T/G] rs894996 4 104418307 [A/C] rs13115641 4 104421641 [A/C] rs7691671 4 104424598 [T/C] rs340451 4 104424934 [T/C] rs10029407 4 104426089 [T/C] rs10001814 4 104428500 [A/G] rs445761 4 104447091 [T/G] rs448991 4 104455234 [T/C] rs451907 4 104457398 [A/G] rs543330 4 104461487 [T/C] rs374474 4 104466726 [A/G] rs10002719 4 104467267 [T/C] rs405717 4 104472071 [A/G] rs419391 4 104474749 [A/G] rs449075 4 104480799 [A/G] rs434269 4 104483419 [T/C] rs11944500 4 104485798 [T/C] rs2588901 4 104490633 [T/C] rs2588907 4 104493370 [A/G] rs13119134 4 104494351 [T/C] rs2588910 4 104495075 [T/C] rs11932144 4 104495431 [T/C] rs6810925 4 104500027 [A/G] rs13124966 4 104500455 [A/G] rs2765 4 104510766 [A/G] NM_001059 TACR3 EXON Silent rs7654507 4 104528309 [T/G] NM_001059 TACR3 Silent rs10013026 4 104532648 [T/C] NM_001059 TACR3 Silent rs11722288 4 104532950 [A/G] NM_001059 TACR3 Silent rs11935705 4 104542360 [A/G] NM_001059 TACR3 Silent rs17033903 4 104543602 [T/C] NM_001059 TACR3 Silent rs17303520 4 104543891 [A/C] NM_001059 TACR3 Silent rs17033923 4 104545046 [T/C] NM_001059 TACR3 Silent rs3796974 4 104545224 [T/C] NM_001059 TACR3 Silent rs1564613 4 104546313 [A/G] NM_001059 TACR3 Silent rs12641703 4 104552687 [A/G] NM_001059 TACR3 Silent rs10516503 4 104553287 [A/C] NM_001059 TACR3 Silent rs3796972 4 104555791 [A/C] NM_001059 TACR3 Silent rs3796969 4 104556666 [A/G] NM_001059 TACR3 Silent rs3796962 4 104574265 [A/G] NM_001059 TACR3 Silent rs11733295 4 104583111 [A/G] NM_001059 TACR3 Silent rs10516506 4 104595253 [T/C] NM_001059 TACR3 Silent rs233976 4 104604469 [A/G] NM_001059 TACR3 Silent rs10019555 4 104615281 [A/G] NM_001059 TACR3 Silent rs10004171 4 104634985 [A/G] NM_001059 TACR3 Silent rs10013998 4 104638193 [A/G] NM_001059 TACR3 Silent rs3733632 4 104640935 [A/G] NM_001059 TACR3 EXON Silent rs17034020 4 104650673 [A/G] rs17034041 4 104654914 [A/G] rs233992 4 104657070 [T/G] rs233991 4 104665738 [A/C] rs4327490 4 104672280 [A/G] rs6833446 4 104674280 [A/G] rs233966 4 104683461 [T/G] rs2189223 4 104695124 [T/C] rs12502493 4 104712494 [A/G] rs12648020 4 104716213 [A/G] rs4698905 4 104719501 [A/G] rs12640158 4 104721398 [T/C] rs6533109 4 104722062 [A/C] rs2189164 4 104725088 [A/G] rs6837683 4 104737913 [A/C] rs12501131 4 104753831 [A/G] rs36096554 4 104757193 [T/C] rs10488855 4 104763949 [A/G] rs11933069 4 104776075 [A/G] rs17034148 4 104778948 [A/G] rs17251970 4 104779025 [T/C] rs2106987 4 104789707 [T/C] rs11937825 4 104792271 [T/C] rs11937871 4 104792456 [T/C] rs9993941 4 104794045 [A/G] rs3857207 4 104830724 [A/G] rs13113456 4 104831108 [T/C] rs12511381 4 104831771 [A/G] rs6845362 4 104834423 [A/C] rs17266258 4 104838047 [T/G] rs12513169 4 104838774 [A/G] rs6853964 4 104843913 [T/G] rs6533118 4 104850169 [A/C] rs6533126 4 104882439 [T/C] rs4272013 4 104890866 [A/G] rs2866672 4 104903537 [T/C] rs11724257 4 104911820 [A/G] rs2951111 4 104919109 [A/C] rs1406639 4 104944893 [A/G] rs11097839 4 104949606 [A/G] rs12651382 4 104955958 [T/G] rs12645446 4 104963745 [T/C] rs11725491 4 104965585 [A/G] rs2134026 4 104972057 [T/C] rs950882 4 104978031 [T/C] rs9996114 4 104988768 [T/C] rs10019375 4 104997276 [T/C] rs1304013 4 105013863 [T/C] rs17306764 4 105039193 [T/C] rs10470905 4 105053161 [A/C] rs13140777 4 105054988 [T/G] rs882920 4 105059801 [T/C] rs13108980 4 105061306 [T/C] rs795121 4 105078507 [A/G] rs9307291 4 105108352 [A/C] rs10015678 4 105140785 [T/C] rs17034369 4 105142122 [T/G] rs4698914 4 105151560 [A/G] rs886329 4 105157058 [T/C] rs1919114 4 105160744 [T/G] rs1528377 4 105183237 [A/G] rs4698917 4 105184685 [T/G] rs9992339 4 105200253 [A/C] rs1919117 4 105217098 [A/G] rs10002598 4 105231571 [T/C] rs11097857 4 105238884 [A/G] rs17268078 4 105239875 [A/G] rs11933178 4 105259892 [T/G] rs17034450 4 105267911 [A/G] rs6843675 4 105306929 [T/C] rs11731936 4 105311957 [T/G] rs10007721 4 105333354 [A/C] rs7657799 4 105375423 [T/G] rs17034525 4 105379450 [T/C] rs2298730 4 105391999 [T/G] NM_025212,NR_132741 CXXC4,CXXC4 EXON Silent,Silent rs10013053 4 105400344 [T/C] NM_025212,NR_132741 CXXC4,CXXC4 Silent,Silent rs11940318 4 105401714 [T/G] NM_025212,NR_132741 CXXC4,CXXC4 Silent,Silent rs9307295 4 105405240 [A/G] NM_025212,NR_132741 CXXC4,CXXC4 Silent,Silent rs4129288 4 105409654 [T/C] NM_025212,NR_132741 CXXC4,CXXC4 Silent,Silent rs3897938 4 105409696 [T/G] NM_025212,NR_132741 CXXC4,CXXC4 Silent,Silent rs10034705 4 105410703 [A/C] NM_025212,NR_132741 CXXC4,CXXC4 Silent,Silent rs4699128 4 105422865 [T/G] NR_125926 CXXC4-AS1 Silent rs17237942 4 105425576 [A/G] NR_125926 CXXC4-AS1 Silent rs11097864 4 105426879 [T/G] NR_125926 CXXC4-AS1 Silent rs7682418 4 105428417 [A/G] NR_125926 CXXC4-AS1 Silent rs4414954 4 105432249 [T/C] NR_125926 CXXC4-AS1 Silent rs7675016 4 105434230 [A/G] NR_125926 CXXC4-AS1 Silent rs10516510 4 105437362 [A/G] NR_125926 CXXC4-AS1 Silent rs10488865 4 105444337 [T/C] NR_125926 CXXC4-AS1 Silent rs2905627 4 105450085 [T/C] NR_125926 CXXC4-AS1 Silent rs2051788 4 105450529 [T/C] NR_125926 CXXC4-AS1 Silent rs2860529 4 105452721 [A/G] NR_125926 CXXC4-AS1 Silent rs1859157 4 105454573 [T/C] NR_125926 CXXC4-AS1 Silent rs17034592 4 105454960 [T/C] NR_125926 CXXC4-AS1 Silent rs3017684 4 105473684 [T/C] NR_125926 CXXC4-AS1 Silent rs3017685 4 105474268 [A/G] NR_125926 CXXC4-AS1 Silent rs3017687 4 105475331 [A/G] NR_125926 CXXC4-AS1 Silent rs3017689 4 105475940 [T/C] NR_125926 CXXC4-AS1 Silent rs6840786 4 105475979 [A/G] NR_125926 CXXC4-AS1 Silent rs11933761 4 105491264 [A/G] NR_125926 CXXC4-AS1 Silent rs17034632 4 105492066 [T/C] NR_125926 CXXC4-AS1 Silent rs1468231 4 105492822 [T/C] NR_125926 CXXC4-AS1 Silent rs3017707 4 105493321 [A/G] NR_125926 CXXC4-AS1 Silent rs7668924 4 105493835 [T/C] NR_125926 CXXC4-AS1 Silent rs1158978 4 105495590 [A/G] NR_125926 CXXC4-AS1 Silent rs11934708 4 105497463 [T/C] NR_125926 CXXC4-AS1 Silent rs3017722 4 105507674 [T/C] NR_125926 CXXC4-AS1 Silent rs494660 4 105509600 [A/G] NR_125926 CXXC4-AS1 Silent rs17034684 4 105511810 [T/G] NR_125926 CXXC4-AS1 Silent rs607012 4 105512358 [T/C] NR_125926 CXXC4-AS1 Silent rs2074395 4 105515047 [A/G] NR_125926 CXXC4-AS1 Silent rs488076 4 105515423 [A/C] NR_125926 CXXC4-AS1 Silent rs17034721 4 105516798 [T/C] NR_125926 CXXC4-AS1 Silent rs9307296 4 105517973 [T/G] NR_125926 CXXC4-AS1 Silent rs555039 4 105518122 [T/C] NR_125926 CXXC4-AS1 Silent rs639114 4 105519735 [A/G] NR_125926 CXXC4-AS1 Silent rs680550 4 105528713 [T/G] NR_125926 CXXC4-AS1 Silent rs477451 4 105528877 [T/C] NR_125926 CXXC4-AS1 Silent rs578265 4 105543843 [T/C] NR_125926 CXXC4-AS1 Silent rs728123 4 105565218 [A/G] NR_125926 CXXC4-AS1 Silent rs624909 4 105566441 [T/G] NR_125926 CXXC4-AS1 Silent rs4698923 4 105581394 [A/G] NR_125926 CXXC4-AS1 Silent rs10005347 4 105582452 [T/C] NR_125926 CXXC4-AS1 Silent rs17034801 4 105585984 [A/C] NR_125926 CXXC4-AS1 Silent rs9986027 4 105591133 [T/G] NR_125926 CXXC4-AS1 Silent rs506932 4 105598022 [T/C] NR_125926 CXXC4-AS1 Silent rs11723224 4 105619841 [A/G] rs2522515 4 105619927 [A/G] rs2651339 4 105624313 [T/G] rs2522502 4 105653263 [A/G] rs2522507 4 105665680 [T/C] rs2428404 4 105679385 [A/G] rs6847856 4 105679402 [A/G] rs4698925 4 105691743 [T/C] rs9996250 4 105691934 [A/G] rs10011811 4 105695174 [A/C] rs2522517 4 105696569 [A/G] rs11726732 4 105700205 [A/G] rs2725762 4 105700542 [A/G] rs1981542 4 105704161 [T/G] rs2725759 4 105706327 [A/G] rs2522524 4 105708053 [T/G] rs2107003 4 105715931 [T/C] rs2051780 4 105716540 [T/C] rs2023829 4 105732804 [A/G] rs2725750 4 105747315 [A/G] rs11946767 4 105747401 [T/C] rs2725771 4 105758739 [T/G] rs2079112 4 105763065 [T/C] rs2522482 4 105768938 [T/C] rs3886330 4 105772094 [T/C] rs4698926 4 105781935 [A/G] rs6850952 4 105792576 [T/G] rs6533163 4 105794260 [A/G] rs4585303 4 105803313 [A/C] rs4274851 4 105811058 [T/C] rs7660445 4 105815547 [A/G] rs9998015 4 105816898 [T/C] rs10516511 4 105821431 [A/C] rs17035104 4 105831150 [A/C] rs4264829 4 105835961 [A/C] rs7695587 4 105838702 [T/C] rs10005603 4 105844273 [T/G] rs9637619 4 105845011 [A/G] rs11935593 4 105849384 [T/C] rs10032763 4 105860001 [A/G] rs17239519 4 105866724 [T/C] rs6533167 4 105869548 [T/C] rs7660636 4 105869983 [T/C] rs4698929 4 105872720 [A/G] rs1490586 4 105890017 [A/C] rs2291507 4 105890515 [A/G] rs17035170 4 105892565 [A/G] rs7688673 4 105897524 [A/G] rs1490579 4 105897585 [A/G] rs1490583 4 105911182 [T/G] rs12500787 4 105921314 [T/G] rs17035202 4 105922523 [T/C] rs902444 4 105923047 [T/C] rs1873361 4 105925099 [T/C] rs4699145 4 105933321 [A/G] rs13151168 4 105936370 [A/G] rs10027139 4 105937236 [T/C] rs1490589 4 105945776 [A/G] rs6831039 4 105959901 [A/G] rs195149 4 105986597 [A/G] rs195148 4 105988057 [T/C] rs2079135 4 106005985 [A/G] rs2079134 4 106006036 [A/G] rs9998451 4 106009472 [A/G] rs2301718 4 106009763 [A/G] rs12509636 4 106010433 [T/C] rs764275 4 106016627 [T/G] rs4141270 4 106022992 [T/C] rs17429675 4 106028073 [A/G] rs2214409 4 106032945 [T/C] rs4698931 4 106034478 [A/G] rs17035270 4 106036545 [T/C] rs1859161 4 106042692 [T/C] rs17035289 4 106048291 [T/C] rs1541374 4 106048360 [T/G] rs7654667 4 106052258 [T/C] rs7679673 4 106061534 [A/C] rs17617028 4 106064683 [A/G] rs17035311 4 106066293 [A/C] rs974801 4 106071064 [A/G] NM_017628,NM_001127208 TET2,TET2 Silent,Silent rs2189234 4 106075498 [T/G] NM_017628,NM_001127208 TET2,TET2 Silent,Silent rs2866773 4 106076506 [A/G] NM_017628,NM_001127208 TET2,TET2 Silent,Silent rs9790517 4 106084778 [T/C] NM_017628,NM_001127208 TET2,TET2 Silent,Silent rs17035323 4 106091978 [A/G] NM_017628,NM_001127208 TET2,TET2 Silent,Silent rs17508261 4 106108902 [T/C] NM_017628,NM_001127208,NR_126420 TET2,TET2,TET2-AS1 Silent,Silent,Silent rs17035325 4 106110796 [T/C] NM_017628,NM_001127208,NR_126420 TET2,TET2,TET2-AS1 Silent,Silent,Silent rs1015521 4 106115450 [T/G] NM_017628,NM_001127208,NR_126420 TET2,TET2,TET2-AS1 Silent,Silent,Silent rs7698522 4 106118756 [T/C] NM_017628,NM_001127208,NR_126420 TET2,TET2,TET2-AS1 Silent,Silent,Silent rs9637601 4 106125715 [A/G] NM_017628,NM_001127208,NR_126420 TET2,TET2,TET2-AS1 Silent,Silent,Silent rs2047409 4 106137033 [A/G] NM_017628,NM_001127208,NR_126420 TET2,TET2,TET2-AS1 Silent,Silent,Silent rs4699166 4 106141736 [A/G] NM_017628,NM_001127208,NR_126420 TET2,TET2,TET2-AS1 Silent,Silent,Silent rs6839705 4 106144735 [A/C] NM_017628,NM_001127208,NR_126420 TET2,TET2,TET2-AS1 Silent,Silent,Silent rs7683416 4 106152984 [T/C] NM_017628,NM_001127208,NR_126420 TET2,TET2,TET2-AS1 Silent,Silent,Silent rs6843141 4 106155751 [A/G] NM_017628,NM_001127208,NR_126420 TET2,TET2,TET2-AS1 EXON Missense_V218M,Missense_V218M,Silent rs17253672 4 106156187 [T/C] NM_017628,NM_001127208,NR_126420 TET2,TET2,TET2-AS1 EXON Missense_P363L,Missense_P363L,Silent rs4145756 4 106157834 [C/G] NM_017628,NM_001127208,NR_126420 TET2,TET2,TET2-AS1 EXON Missense_A912G,Missense_A912G,Silent rs3796927 4 106158216 [A/G] NM_017628,NM_001127208,NR_126420 TET2,TET2,TET2-AS1 EXON Synonymous_S1039S,Synonymous_S1039S,Silent rs7670522 4 106160365 [A/C] NM_017628,NM_001127208,NR_126420 TET2,TET2,TET2-AS1 EXON Silent,Silent,Silent rs4464576 4 106177882 [A/G] NM_001127208,NR_126420 TET2,TET2-AS1 Silent,Silent rs2726492 4 106195541 [T/C] NM_001127208,NR_126420 TET2,TET2-AS1 Silent,Silent rs2454206 4 106196951 [A/G] NM_001127208,NR_126420 TET2,TET2-AS1 EXON Missense_I1762V,Silent rs2647256 4 106201556 [T/C] NR_126420 TET2-AS1 Silent rs904274 4 106202633 [A/C] NR_126420 TET2-AS1 Silent rs6533185 4 106213874 [A/G] NR_126420 TET2-AS1 Silent rs12639764 4 106216205 [T/C] NR_126420 TET2-AS1 Silent rs10516518 4 106235012 [T/C] NR_126420 TET2-AS1 Silent rs6827660 4 106239038 [T/C] NR_126420 TET2-AS1 Silent rs17035461 4 106253209 [A/G] NR_126420 TET2-AS1 Silent rs2647259 4 106256521 [A/C] NR_126420 TET2-AS1 Silent rs2726485 4 106263450 [T/G] NR_126420 TET2-AS1 Silent rs6823995 4 106263681 [T/C] NR_126420 TET2-AS1 Silent rs2726486 4 106264681 [T/C] NR_126420 TET2-AS1 Silent rs2647266 4 106270291 [A/G] NR_126420 TET2-AS1 Silent rs924283 4 106282165 [T/C] rs2647254 4 106285090 [A/G] rs2726496 4 106288827 [T/C] rs13108489 4 106293125 [A/G] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs2636693 4 106294756 [T/C] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs2713833 4 106297376 [T/C] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs2726503 4 106298394 [A/G] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs2726528 4 106316427 [T/C] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs959086 4 106318456 [A/G] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs17035553 4 106321423 [T/C] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs2713871 4 106325106 [T/G] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs2726471 4 106335490 [T/G] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs2636740 4 106338434 [T/C] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs11721982 4 106338490 [A/C] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs2726516 4 106346206 [A/C] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs753972 4 106353784 [A/G] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs17035584 4 106354786 [A/G] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs3898404 4 106356395 [T/C] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs2636743 4 106356581 [T/C] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs17035594 4 106361234 [A/G] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs923587 4 106364129 [A/G] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs2636751 4 106366209 [T/C] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs7671891 4 106366687 [T/C] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs2029513 4 106382268 [T/C] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs12643660 4 106386760 [T/G] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs4699176 4 106388702 [T/G] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs2298733 4 106390734 [A/C] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs2074396 4 106394380 [A/C] NM_006903,NM_176867,NM_176869,NM_176866 PPA2,PPA2,PPA2,PPA2 Silent,Silent,Silent,Silent rs12507480 4 106399576 [A/G] rs10488941 4 106401082 [A/C] rs11097891 4 106408926 [T/C] rs757176 4 106412529 [A/C] rs17617523 4 106429568 [T/C] rs9307305 4 106442518 [T/C] rs3864227 4 106447752 [T/C] rs4082504 4 106448900 [A/C] rs12499086 4 106451311 [A/G] rs17035675 4 106457954 [T/G] rs1388040 4 106459205 [A/G] rs11730243 4 106463713 [T/C] rs2079129 4 106466334 [A/G] rs6858204 4 106467126 [T/C] rs17617811 4 106467767 [T/C] rs3756258 4 106472259 [T/C] rs17035736 4 106472904 [A/G] rs10032241 4 106474078 [A/G] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 EXON Synonymous_R52R,Synonymous_R52R rs3796915 4 106474576 [A/C] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs6816893 4 106477417 [T/C] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs4699189 4 106482235 [T/G] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs9996656 4 106482715 [A/G] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs6533209 4 106482887 [A/G] NM_017700,NM_001242729,NR_046840 ARHGEF38,ARHGEF38,ARHGEF38-IT1 Silent,Silent,Silent rs6533210 4 106483327 [A/G] NM_017700,NM_001242729,NR_046840 ARHGEF38,ARHGEF38,ARHGEF38-IT1 Silent,Silent,Silent rs17584487 4 106483898 [A/G] NM_017700,NM_001242729,NR_046840 ARHGEF38,ARHGEF38,ARHGEF38-IT1 Silent,Silent,Silent rs10433994 4 106485194 [A/G] NM_017700,NM_001242729,NR_046840 ARHGEF38,ARHGEF38,ARHGEF38-IT1 Silent,Silent,Silent rs11097894 4 106485474 [T/C] NM_017700,NM_001242729,NR_046840 ARHGEF38,ARHGEF38,ARHGEF38-IT1 Silent,Silent,Silent rs6813330 4 106485745 [T/C] NM_017700,NM_001242729,NR_046840 ARHGEF38,ARHGEF38,ARHGEF38-IT1 Silent,Silent,Silent rs6533212 4 106485836 [T/C] NM_017700,NM_001242729,NR_046840 ARHGEF38,ARHGEF38,ARHGEF38-IT1 Silent,Silent,Silent rs7684945 4 106486584 [A/C] NM_017700,NM_001242729,NR_046840 ARHGEF38,ARHGEF38,ARHGEF38-IT1 Silent,Silent,Silent rs199330 4 106504943 [T/C] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs11935777 4 106506244 [A/G] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs2276970 4 106510470 [A/G] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 EXON Missense_M88V,Missense_M88V rs715706 4 106516028 [T/C] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs17035917 4 106520742 [T/C] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs11721732 4 106521514 [A/G] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs1374530 4 106523977 [T/C] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs7687176 4 106527106 [T/C] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs13138544 4 106531758 [A/G] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs10516520 4 106534110 [A/G] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs11944959 4 106543844 [A/G] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs10007278 4 106549096 [T/G] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 Silent,Silent rs2044536 4 106552414 [A/G] NM_017700,NM_001242729 ARHGEF38,ARHGEF38 EXON Silent,Silent rs10516521 4 106553247 [A/G] NM_001242729 ARHGEF38 Silent rs9999670 4 106559184 [A/G] NM_001242729 ARHGEF38 Silent rs1447096 4 106559378 [T/G] NM_001242729 ARHGEF38 Silent rs1374534 4 106572456 [T/C] NM_001242729 ARHGEF38 Silent rs17036076 4 106575269 [A/G] NM_001242729 ARHGEF38 EXON Synonymous_L352L rs10461140 4 106582473 [T/C] NM_001242729 ARHGEF38 Silent rs10019217 4 106588509 [T/C] NM_001242729 ARHGEF38 Silent rs4235415 4 106593850 [A/G] NM_001242729 ARHGEF38 Silent rs11930965 4 106594625 [A/G] NM_001242729 ARHGEF38 Silent rs17036093 4 106595055 [A/C] NM_001242729 ARHGEF38 Silent rs17262087 4 106597582 [T/C] NM_001242729 ARHGEF38 Silent rs4699193 4 106601989 [T/C] NM_001242729 ARHGEF38 EXON Silent rs17036102 4 106603098 [T/C] rs10008158 4 106604223 [A/G] NM_020395,NM_001142471 INTS12,INTS12 EXON Synonymous_N352N,Synonymous_N352N rs6820671 4 106613821 [A/G] NM_020395,NM_001142471 INTS12,INTS12 Silent,Silent rs17262443 4 106614806 [T/C] NM_020395,NM_001142471 INTS12,INTS12 Silent,Silent rs17262457 4 106618362 [T/C] NM_020395,NM_001142471 INTS12,INTS12 Silent,Silent rs3213950 4 106621169 [T/C] NM_020395,NM_001142471 INTS12,INTS12 EXON Silent,Silent rs7659526 4 106621643 [T/C] NM_020395,NM_001142471 INTS12,INTS12 Silent,Silent rs17036123 4 106622190 [T/C] NM_020395,NM_001142471 INTS12,INTS12 Silent,Silent rs17036129 4 106624529 [T/C] NM_020395,NM_001142471 INTS12,INTS12 Silent,Silent rs10516523 4 106625263 [T/G] NM_020395,NM_001142471 INTS12,INTS12 Silent,Silent rs6850604 4 106628380 [T/G] NM_020395,NM_001142471 INTS12,INTS12 Silent,Silent rs17262764 4 106629009 [A/G] NM_020395,NM_001142471 INTS12,INTS12 Silent,Silent rs28403197 4 106629567 [A/G] NM_020395,NM_001142471 INTS12,INTS12 Silent,Silent rs4699196 4 106630949 [T/C] NM_024751 GSTCD Silent rs11727735 4 106631870 [A/G] NM_024751 GSTCD Silent rs10516524 4 106632436 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs17036139 4 106632657 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs11724839 4 106638256 [T/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs4699197 4 106641923 [T/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs10026561 4 106643403 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs6820200 4 106643445 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs11731533 4 106649309 [T/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs1294671 4 106657151 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs12511885 4 106662118 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs11934139 4 106663541 [T/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs11097896 4 106666359 [T/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs11722731 4 106666773 [T/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs7676226 4 106668358 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs9991722 4 106669594 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs10022879 4 106671992 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs4698951 4 106672198 [T/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2193852 4 106680764 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2866781 4 106681251 [T/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2544402 4 106687733 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2544401 4 106688976 [T/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2553446 4 106696476 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2553449 4 106698892 [T/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs6825379 4 106704166 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2544396 4 106704773 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs11733287 4 106705339 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2544395 4 106705863 [T/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2080788 4 106707226 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2553471 4 106709583 [T/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2553470 4 106713673 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2544426 4 106717797 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2544424 4 106718316 [T/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2553468 4 106722298 [A/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2544422 4 106723497 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2553467 4 106724328 [T/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2193857 4 106727328 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2553461 4 106731410 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2553460 4 106732183 [T/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2553459 4 106732957 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs17036254 4 106736355 [A/G] NM_024751,NM_001031720,NR_125927 GSTCD,GSTCD,LOC101929529 EXON Silent,Silent,Silent rs2553458 4 106737796 [A/G] NM_024751,NM_001031720,NR_125927 GSTCD,GSTCD,LOC101929529 Silent,Silent,Silent rs17264527 4 106741424 [T/C] NM_024751,NM_001031720,NR_125927 GSTCD,GSTCD,LOC101929529 Silent,Silent,Silent rs2544418 4 106741974 [T/C] NM_024751,NM_001031720,NR_125927 GSTCD,GSTCD,LOC101929529 Silent,Silent,Silent rs2193856 4 106742958 [A/C] NM_024751,NM_001031720,NR_125927 GSTCD,GSTCD,LOC101929529 Silent,Silent,Silent rs9992325 4 106745057 [T/C] NM_024751,NM_001031720,NR_125927 GSTCD,GSTCD,LOC101929529 Silent,Silent,Silent rs2544417 4 106745405 [A/G] NM_024751,NM_001031720,NR_125927 GSTCD,GSTCD,LOC101929529 Silent,Silent,Silent rs11726674 4 106745751 [T/C] NM_024751,NM_001031720,NR_125927 GSTCD,GSTCD,LOC101929529 Silent,Silent,Silent rs11731417 4 106746012 [A/G] NM_024751,NM_001031720,NR_125927 GSTCD,GSTCD,LOC101929529 Silent,Silent,Silent rs2216515 4 106750214 [T/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2553456 4 106751028 [T/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2112051 4 106751231 [A/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs6533218 4 106753845 [A/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs9994835 4 106758653 [A/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs10026373 4 106760931 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2544412 4 106761837 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs12331437 4 106763085 [A/C] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs10050159 4 106765915 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD Silent,Silent rs2553444 4 106767490 [T/C] NM_024751,NM_001031720 GSTCD,GSTCD EXON Silent,Silent rs17036337 4 106767741 [A/G] NM_024751,NM_001031720 GSTCD,GSTCD EXON Silent,Silent rs17036339 4 106767743 [T/G] NM_024751,NM_001031720 GSTCD,GSTCD EXON Silent,Silent rs2553453 4 106808172 [A/G] rs11731982 4 106820344 [T/G] NM_001033047,NM_001184690,NM_001184692,NM_001184693,NM_001184691 NPNT,NPNT,NPNT,NPNT,NPNT Silent,Silent,Silent,Silent,Silent rs10007955 4 106820702 [T/C] NM_001033047,NM_001184690,NM_001184692,NM_001184693,NM_001184691 NPNT,NPNT,NPNT,NPNT,NPNT Silent,Silent,Silent,Silent,Silent rs4600917 4 106829645 [T/C] NM_001033047,NM_001184690,NM_001184692,NM_001184693,NM_001184691 NPNT,NPNT,NPNT,NPNT,NPNT Silent,Silent,Silent,Silent,Silent rs6811135 4 106830232 [A/G] NM_001033047,NM_001184690,NM_001184692,NM_001184693,NM_001184691 NPNT,NPNT,NPNT,NPNT,NPNT Silent,Silent,Silent,Silent,Silent rs4507363 4 106857657 [A/G] NM_001033047,NM_001184690,NM_001184692,NM_001184693,NM_001184691 NPNT,NPNT,NPNT,NPNT,NPNT Silent,Silent,Silent,Silent,Silent rs4340795 4 106861730 [A/G] NM_001033047,NM_001184690,NM_001184692,NM_001184693,NM_001184691 NPNT,NPNT,NPNT,NPNT,NPNT EXON Missense_I234V,Missense_I251V,Missense_I234V,Missense_I264V,Missense_I264V rs6843517 4 106870409 [A/G] NM_001033047,NM_001184690,NM_001184692,NM_001184693,NM_001184691 NPNT,NPNT,NPNT,NPNT,NPNT Silent,Silent,Silent,Silent,Silent rs7677557 4 106872861 [T/C] NM_001033047,NM_001184690,NM_001184692,NM_001184693,NM_001184691 NPNT,NPNT,NPNT,NPNT,NPNT Silent,Silent,Silent,Silent,Silent rs6855132 4 106877631 [A/G] NM_001033047,NM_001184690,NM_001184692,NM_001184693,NM_001184691 NPNT,NPNT,NPNT,NPNT,NPNT Silent,Silent,Silent,Silent,Silent rs7680832 4 106887163 [A/G] NM_001033047,NM_001184690,NM_001184692,NM_001184693,NM_001184691 NPNT,NPNT,NPNT,NPNT,NPNT Silent,Silent,Silent,Silent,Silent rs4597836 4 106888263 [A/C] NM_001033047,NM_001184690,NM_001184692,NM_001184693,NM_001184691 NPNT,NPNT,NPNT,NPNT,NPNT Silent,Silent,Silent,Silent,Silent rs11733103 4 106890370 [T/C] NM_001033047,NM_001184690,NM_001184692,NM_001184693,NM_001184691 NPNT,NPNT,NPNT,NPNT,NPNT EXON Silent,Silent,Silent,Silent,Silent rs6817700 4 106891531 [A/G] NM_001033047,NM_001184690,NM_001184692,NM_001184693,NM_001184691 NPNT,NPNT,NPNT,NPNT,NPNT EXON Silent,Silent,Silent,Silent,Silent rs11735326 4 106891894 [A/G] NM_001033047,NM_001184690,NM_001184692,NM_001184693,NM_001184691 NPNT,NPNT,NPNT,NPNT,NPNT EXON Silent,Silent,Silent,Silent,Silent rs17036413 4 106894867 [T/C] rs4345186 4 106915834 [A/G] rs4367177 4 106921594 [T/C] rs994370 4 106923626 [T/C] rs17199327 4 106926748 [A/C] NR_125928 LOC101929577 Silent rs10001483 4 106936604 [A/G] NR_125928 LOC101929577 Silent rs4611932 4 106938490 [A/G] NR_125928 LOC101929577 Silent rs6853554 4 106947487 [A/G] rs6842919 4 106958170 [A/G] rs17036535 4 106964945 [A/C] rs11941861 4 106965224 [A/G] rs1227 4 106967282 [T/C] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK EXON Silent,Silent,Silent,Silent,Silent rs7683106 4 106970272 [A/C] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs17036551 4 106970976 [A/C] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs10023586 4 106973602 [A/G] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs2212969 4 106979479 [T/C] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs13101737 4 106982793 [A/C] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs28697941 4 106996077 [A/G] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs17272618 4 107022503 [T/C] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs4956269 4 107060274 [T/G] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs17273600 4 107127490 [T/C] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs13101612 4 107128360 [A/G] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs13106209 4 107171131 [A/G] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs12641015 4 107172182 [T/C] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs13129572 4 107174698 [A/G] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs10033060 4 107175191 [T/C] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs12504721 4 107178254 [T/C] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs727618 4 107179126 [T/C] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs7662395 4 107185855 [T/C] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs17036654 4 107217398 [A/G] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs3762947 4 107236648 [A/G] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435 TBCK,TBCK,TBCK,TBCK,TBCK Silent,Silent,Silent,Silent,Silent rs6814166 4 107237395 [T/C] NM_001290768,NM_033115,NM_001163436,NM_001163437,NM_001163435,NM_001142415,NM_004757 TBCK,TBCK,TBCK,TBCK,TBCK,AIMP1,AIMP1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3737498 4 107246136 [A/C] NM_001142415,NM_004757,NM_001142416 AIMP1,AIMP1,AIMP1 Silent,Silent,Silent rs10017777 4 107256493 [T/C] NM_001142415,NM_004757,NM_001142416 AIMP1,AIMP1,AIMP1 Silent,Silent,Silent rs12642454 4 107266883 [A/G] NM_001142415,NM_004757,NM_001142416 AIMP1,AIMP1,AIMP1 Silent,Silent,Silent rs3805410 4 107268949 [A/G] NM_001142415,NM_004757,NM_001142416 AIMP1,AIMP1,AIMP1 EXON Silent,Silent,Silent rs7654865 4 107279450 [T/C] NM_001195138 GIMD1 EXON Missense_V182I rs3018058 4 107281920 [A/G] NM_001195138 GIMD1 Silent rs3018059 4 107282566 [A/G] NM_001195138 GIMD1 Silent rs2949646 4 107288449 [A/G] NM_001195138 GIMD1 EXON Synonymous_S48S rs3018066 4 107289526 [A/G] rs3108151 4 107295179 [A/G] rs7697673 4 107296620 [T/G] rs2949619 4 107302260 [A/G] rs3108146 4 107303131 [A/G] rs2949623 4 107304010 [A/G] rs3113243 4 107308215 [A/C] rs2949640 4 107310178 [T/G] rs2949641 4 107310444 [A/G] rs4340862 4 107318580 [T/C] rs3018056 4 107329974 [T/C] rs3108140 4 107334044 [T/C] rs17276911 4 107334361 [T/C] rs877773 4 107347064 [T/C] rs940617 4 107353688 [A/G] rs6820792 4 107363636 [A/G] NR_147150 LINC02173 Silent rs2903421 4 107370685 [A/G] NR_147150 LINC02173 Silent rs17036750 4 107383617 [T/C] rs28831403 4 107388882 [T/C] rs10516535 4 107394976 [T/C] rs7676915 4 107413991 [T/C] rs4495119 4 107419151 [A/C] rs13148020 4 107423164 [A/C] rs16996905 4 107424278 [T/C] rs1522221 4 107427351 [T/C] rs1522218 4 107431789 [A/G] rs7690115 4 107448046 [T/C] rs7672970 4 107470497 [A/G] rs2686308 4 107471140 [A/G] rs2648048 4 107477804 [T/C] rs769169 4 107486817 [T/C] rs17358000 4 107487061 [T/C] rs10024795 4 107498301 [T/C] rs10008290 4 107499928 [A/G] rs10034263 4 107501341 [A/G] rs17358405 4 107502557 [T/C] rs764538 4 107504175 [A/G] rs2648031 4 107509092 [T/C] rs1522215 4 107517238 [A/G] rs2648037 4 107520859 [T/G] rs2686311 4 107526541 [A/G] rs2553205 4 107527205 [A/C] rs2686305 4 107533620 [T/C] rs4956261 4 107536850 [A/G] rs1023792 4 107537390 [A/G] rs4340861 4 107547518 [T/C] rs2686297 4 107549400 [T/C] rs1425261 4 107583181 [T/C] rs2587136 4 107587752 [T/C] rs13141555 4 107588257 [A/G] rs4956263 4 107591650 [T/G] rs10010360 4 107601518 [T/C] rs2081453 4 107604335 [T/G] rs1425258 4 107608787 [A/G] rs2553207 4 107609695 [T/G] rs12646341 4 107613144 [T/C] rs1545296 4 107618284 [T/C] rs9784417 4 107625430 [A/G] rs1443893 4 107637162 [T/G] rs11725068 4 107654106 [T/G] rs7695009 4 107654943 [A/G] rs11097937 4 107663696 [T/C] rs1425249 4 107666927 [A/G] rs12508455 4 107685776 [T/G] rs817147 4 107708035 [T/C] rs12510474 4 107745306 [A/G] rs9985689 4 107745361 [T/C] rs11733406 4 107751089 [A/G] rs11943338 4 107769255 [A/G] rs10014676 4 107773179 [A/G] rs11940657 4 107807776 [A/G] rs2324 4 107826705 [A/G] rs450533 4 107830261 [T/C] rs422661 4 107841693 [A/G] rs402586 4 107842959 [T/C] NM_014421 DKK2 EXON Silent rs10488898 4 107843493 [A/G] NM_014421 DKK2 EXON Silent rs419558 4 107844092 [T/C] NM_014421 DKK2 EXON Silent rs419764 4 107844157 [T/C] NM_014421 DKK2 EXON Silent rs17037102 4 107845794 [T/C] NM_014421 DKK2 EXON Missense_R146Q rs433201 4 107851275 [A/G] NM_014421 DKK2 Silent rs9995574 4 107855336 [A/G] NM_014421 DKK2 Silent rs10488899 4 107864811 [T/G] NM_014421 DKK2 Silent rs17431749 4 107888737 [T/C] NM_014421 DKK2 Silent rs396196 4 107889798 [T/C] NM_014421 DKK2 Silent rs2051756 4 107903545 [T/C] NM_014421 DKK2 Silent rs2866908 4 107905508 [A/G] NM_014421 DKK2 Silent rs1012949 4 107920373 [T/C] NM_014421 DKK2 Silent rs7696721 4 107924576 [T/C] NM_014421 DKK2 Silent rs4956274 4 107939938 [T/C] NM_014421 DKK2 Silent rs4956275 4 107946161 [T/C] NM_014421 DKK2 Silent rs2212966 4 107947618 [A/G] NM_014421 DKK2 Silent rs17037282 4 107948377 [A/G] NM_014421 DKK2 Silent rs10021344 4 107951360 [A/G] NM_014421 DKK2 Silent rs956137 4 107953879 [T/G] NM_014421 DKK2 Silent rs3733635 4 107956905 [A/G] NM_014421 DKK2 EXON Silent rs2704335 4 107958376 [T/G] rs13147822 4 107960572 [A/G] rs383567 4 107961767 [A/G] rs7685856 4 107970647 [T/C] rs17584885 4 107974736 [T/C] rs419783 4 107976020 [T/C] rs398093 4 107980550 [T/C] rs2704324 4 107984723 [A/C] rs441202 4 107988210 [A/G] rs386499 4 107993687 [T/C] rs378405 4 108000247 [A/C] rs6849760 4 108007908 [A/G] rs403608 4 108015733 [A/G] rs425273 4 108016162 [T/C] rs81299 4 108017272 [A/C] rs382525 4 108018123 [T/C] rs435887 4 108020599 [A/G] rs17510289 4 108035955 [T/C] rs373586 4 108040129 [A/G] rs404662 4 108040751 [T/C] rs412908 4 108041804 [T/C] rs6533280 4 108043696 [A/C] rs6826953 4 108047174 [T/G] rs17510449 4 108048311 [A/G] rs2158182 4 108048977 [A/C] rs7683840 4 108049786 [A/G] rs718820 4 108051500 [T/C] rs10489128 4 108065738 [A/C] rs2850405 4 108068274 [T/C] rs28513708 4 108071458 [A/C] rs6835222 4 108073210 [A/G] rs10020435 4 108081536 [A/G] rs1807847 4 108083471 [T/C] rs7694364 4 108084614 [T/C] rs12512114 4 108086688 [T/C] rs17037473 4 108094650 [A/G] rs10155071 4 108104369 [A/G] rs12511906 4 108105844 [A/G] rs995773 4 108106754 [A/G] rs950252 4 108109894 [A/G] rs17483781 4 108115022 [T/C] rs1027253 4 108117467 [A/G] rs17549820 4 108118301 [T/C] rs2029635 4 108119422 [A/G] rs4403120 4 108120442 [A/G] rs17037525 4 108120955 [T/C] rs17037547 4 108127486 [T/C] rs4956005 4 108132331 [T/C] rs7691374 4 108133070 [A/C] rs6827724 4 108135377 [A/G] rs6828013 4 108135681 [T/C] rs1492473 4 108145936 [T/G] rs12646290 4 108146502 [T/C] rs959482 4 108148408 [T/C] rs1388845 4 108156306 [A/G] rs1021420 4 108158105 [T/C] rs4956081 4 108164882 [T/G] rs11722765 4 108167905 [T/C] rs1873710 4 108174195 [T/G] rs931481 4 108174391 [T/C] rs17037583 4 108177310 [T/C] rs10019755 4 108181819 [A/G] rs1038854 4 108189246 [A/G] rs1027655 4 108195600 [T/C] rs1393587 4 108197243 [A/G] rs1388850 4 108197862 [A/C] rs11946611 4 108206062 [T/C] rs7681472 4 108207425 [A/C] rs1056079 4 108222771 [A/C] rs6533295 4 108231167 [T/C] rs717435 4 108233063 [T/C] rs203734 4 108237682 [A/C] rs1023514 4 108239396 [A/G] rs1502773 4 108266027 [A/G] rs17218497 4 108284661 [T/C] rs203721 4 108296579 [A/G] rs9684679 4 108300001 [T/C] rs7680755 4 108304505 [T/C] rs6847720 4 108312043 [T/C] rs10488872 4 108313081 [T/C] rs6837260 4 108314588 [A/G] rs1502768 4 108316493 [T/G] rs203217 4 108320885 [A/G] rs203221 4 108324658 [A/G] rs203223 4 108326530 [T/G] rs203227 4 108327835 [A/G] rs10007314 4 108347993 [T/C] rs7687890 4 108356085 [A/G] rs7665293 4 108365132 [A/G] rs10008982 4 108373816 [T/C] rs11722979 4 108381600 [A/C] rs10023658 4 108383641 [A/C] rs2214389 4 108387300 [T/G] rs7692560 4 108390499 [T/C] rs10005025 4 108392974 [T/C] rs17501731 4 108396913 [A/C] rs2189201 4 108414125 [A/G] rs1399403 4 108419815 [T/G] rs17037788 4 108422651 [T/C] rs11942323 4 108458314 [A/G] rs2672469 4 108462490 [T/C] rs1514728 4 108474586 [T/G] rs2726692 4 108493334 [A/G] rs10516545 4 108493705 [A/G] rs932100 4 108506584 [A/G] rs12648912 4 108517790 [T/G] rs10010106 4 108525128 [A/G] rs1514730 4 108530885 [T/C] rs2726180 4 108534358 [T/G] rs9569 4 108535335 [T/C] NM_005443 PAPSS1 EXON Silent rs2672487 4 108537766 [A/G] NM_005443 PAPSS1 Silent rs2726673 4 108541282 [A/C] NM_005443 PAPSS1 Silent rs4956111 4 108547865 [T/C] NM_005443 PAPSS1 Silent rs2672458 4 108557559 [A/G] NM_005443 PAPSS1 Silent rs10461141 4 108562555 [A/G] NM_005443 PAPSS1 Silent rs2726659 4 108565215 [T/C] NM_005443 PAPSS1 Silent rs2726655 4 108572567 [T/C] NM_005443 PAPSS1 Silent rs3733633 4 108575989 [A/G] NM_005443 PAPSS1 EXON Synonymous_D321D rs3805342 4 108584007 [A/G] NM_005443 PAPSS1 Silent rs4956024 4 108592665 [T/C] NM_005443 PAPSS1 Silent rs1476086 4 108593062 [A/G] NM_005443 PAPSS1 Silent rs3805347 4 108602062 [A/G] NM_005443 PAPSS1 Silent rs12502059 4 108605212 [A/G] NM_005443 PAPSS1 Silent rs3811807 4 108606943 [T/C] NM_005443 PAPSS1 Silent rs2522420 4 108609628 [A/C] NM_005443 PAPSS1 Silent rs2522422 4 108611941 [A/G] NM_005443 PAPSS1 Silent rs2522425 4 108618232 [T/C] NM_005443 PAPSS1 Silent rs2522426 4 108621483 [T/C] NM_005443 PAPSS1 Silent rs13110240 4 108622475 [T/C] NM_005443 PAPSS1 Silent rs2726176 4 108633506 [A/C] NM_005443 PAPSS1 Silent rs2726207 4 108639491 [A/C] NM_005443 PAPSS1 Silent rs2189158 4 108655834 [T/C] rs11732603 4 108671723 [T/C] rs4585383 4 108681819 [A/G] rs10027815 4 108691131 [A/G] rs1826712 4 108717195 [A/G] rs7665836 4 108731771 [A/G] rs10008418 4 108732508 [A/G] rs1389166 4 108758470 [A/C] NM_001136258 SGMS2 Silent rs1389167 4 108758579 [A/C] NM_001136258 SGMS2 Silent rs1493125 4 108762203 [A/G] NM_001136258 SGMS2 Silent rs2087874 4 108778519 [T/G] NM_001136258 SGMS2 Silent rs17038136 4 108782756 [T/C] NM_001136258 SGMS2 Silent rs10516546 4 108784514 [A/G] NM_001136258 SGMS2 Silent rs11940819 4 108788680 [A/G] NM_001136258,NR_125929 SGMS2,LOC101929595 EXON Silent,Silent rs7671347 4 108792735 [A/G] NM_001136258,NR_125929 SGMS2,LOC101929595 Silent,Silent rs975219 4 108794544 [A/G] NM_001136258,NR_125929 SGMS2,LOC101929595 EXON Silent,Silent rs17038153 4 108794813 [T/C] NM_001136258,NR_125929 SGMS2,LOC101929595 Silent,Silent rs17563270 4 108797741 [A/G] NM_001136258,NR_125929 SGMS2,LOC101929595 Silent,Silent rs6811703 4 108802411 [A/G] NM_001136258,NR_125929 SGMS2,LOC101929595 Silent,Silent rs12648528 4 108802762 [T/G] NM_001136258,NR_125929 SGMS2,LOC101929595 Silent,Silent rs17563597 4 108818653 [T/C] NM_001136258,NR_125929,NM_001136257,NM_152621 SGMS2,LOC101929595,SGMS2,SGMS2 Silent,Silent,Silent,Silent rs1160677 4 108818757 [A/C] NM_001136258,NR_125929,NM_001136257,NM_152621 SGMS2,LOC101929595,SGMS2,SGMS2 Silent,Silent,Silent,Silent rs6826111 4 108823320 [T/C] NM_001136258,NR_125929,NM_001136257,NM_152621 SGMS2,LOC101929595,SGMS2,SGMS2 Silent,Silent,Silent,Silent rs10007396 4 108825559 [A/G] NM_001136258,NR_125929,NM_001136257,NM_152621 SGMS2,LOC101929595,SGMS2,SGMS2 Silent,Silent,Silent,Silent rs13144835 4 108829343 [T/C] NM_001136258,NR_125929,NM_001136257,NM_152621 SGMS2,LOC101929595,SGMS2,SGMS2 Silent,Silent,Silent,Silent rs11945554 4 108832286 [A/G] NM_001136258,NR_125929,NM_001136257,NM_152621 SGMS2,LOC101929595,SGMS2,SGMS2 EXON Silent,Silent,Silent,Silent rs13103176 4 108834529 [T/G] NM_001136258,NR_125929,NM_001136257,NM_152621 SGMS2,LOC101929595,SGMS2,SGMS2 EXON Silent,Silent,Silent,Silent rs4428357 4 108838908 [A/G] NR_125929 LOC101929595 Silent rs4956140 4 108848793 [A/G] NR_125929 LOC101929595 Silent rs4956029 4 108851574 [T/C] NR_125929 LOC101929595 Silent rs2131463 4 108855776 [A/G] NM_183075 CYP2U1 Silent rs4956031 4 108857140 [T/C] NM_183075 CYP2U1 Silent rs1493131 4 108860906 [A/G] NM_183075 CYP2U1 Silent rs6533327 4 108861140 [A/G] NM_183075 CYP2U1 Silent rs8727 4 108873285 [T/C] NM_183075 CYP2U1 EXON Silent rs3756271 4 108874039 [A/C] NM_183075 CYP2U1 EXON Silent rs4451004 4 108890396 [A/G] rs17565061 4 108906300 [T/C] rs17038277 4 108909511 [T/G] rs221336 4 108909988 [T/C] rs17038289 4 108912239 [A/G] NM_001184705,NM_005327 HADH,HADH Silent,Silent rs221330 4 108921367 [A/G] NM_001184705,NM_005327 HADH,HADH Silent,Silent rs4956145 4 108931039 [T/C] NM_001184705,NM_005327,NM_001331027 HADH,HADH,HADH EXON Missense_L86P,Missense_L86P,Missense_L90P rs7691506 4 108941283 [A/G] NM_001184705,NM_005327,NM_001331027 HADH,HADH,HADH Silent,Silent,Silent rs7664031 4 108944101 [T/C] NM_001184705,NM_005327,NM_001331027 HADH,HADH,HADH Silent,Silent,Silent rs3796992 4 108945631 [T/C] NM_001184705,NM_005327,NM_001331027 HADH,HADH,HADH Silent,Silent,Silent rs4245924 4 108946378 [T/C] NM_001184705,NM_005327,NM_001331027 HADH,HADH,HADH Silent,Silent,Silent rs6831530 4 108956423 [T/G] rs6851442 4 108959282 [A/G] rs4956035 4 108960709 [A/G] rs4245926 4 108967846 [A/G] rs4245927 4 108969590 [A/G] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 EXON Silent,Silent,Silent,Silent rs10034874 4 108978450 [T/C] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs6826687 4 108980772 [A/G] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs4613638 4 108985388 [A/G] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs1291490 4 108994012 [T/C] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs4956157 4 108999366 [A/G] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs3796999 4 109003752 [T/C] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs4403119 4 109004975 [A/G] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs4547871 4 109009087 [A/G] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs898518 4 109016824 [A/C] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs10022956 4 109033979 [T/C] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs10516550 4 109035828 [T/C] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs10516551 4 109035985 [T/C] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs4624731 4 109044868 [A/G] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs6533354 4 109055567 [A/G] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs6827893 4 109055951 [A/C] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs17038630 4 109056791 [T/G] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs922167 4 109060364 [T/C] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs12503104 4 109062510 [T/C] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs10516552 4 109065394 [A/C] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs922163 4 109066366 [T/C] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs17038678 4 109074499 [T/C] NM_001166119,NM_016269,NM_001130713,NM_001130714 LEF1,LEF1,LEF1,LEF1 Silent,Silent,Silent,Silent rs2343113 4 109104682 [A/G] rs10000124 4 109106451 [A/C] rs2343115 4 109111726 [A/C] rs2221145 4 109111753 [A/G] rs4956041 4 109113914 [T/C] rs17567325 4 109119628 [T/C] rs4956042 4 109142299 [A/C] rs12501237 4 109143439 [A/G] rs7671754 4 109151467 [T/C] rs10026586 4 109162596 [A/G] rs11097974 4 109163035 [T/C] rs13140104 4 109163364 [A/G] rs10003044 4 109167462 [A/C] rs931771 4 109172913 [T/C] rs1003169 4 109176161 [A/G] rs7665502 4 109180551 [A/G] rs11934029 4 109182392 [T/G] rs3901937 4 109192876 [A/G] rs13139506 4 109193333 [A/C] rs11725852 4 109196994 [T/C] rs924722 4 109199366 [T/C] rs17606736 4 109199718 [T/C] rs220601 4 109202036 [A/C] rs12507470 4 109211978 [A/G] rs1473555 4 109218677 [A/G] rs1393825 4 109231090 [T/C] rs220633 4 109235102 [A/C] rs220634 4 109235238 [T/C] rs220636 4 109235352 [T/C] rs852269 4 109236454 [T/C] rs220612 4 109238322 [T/C] rs220623 4 109243057 [T/C] rs17608469 4 109251708 [A/G] rs17038822 4 109254423 [T/C] rs929447 4 109259515 [T/C] rs13138626 4 109263671 [A/G] rs12108639 4 109264055 [A/G] rs11940782 4 109272140 [A/G] rs917413 4 109275454 [T/G] rs1558172 4 109276830 [A/G] rs10489025 4 109282683 [A/C] rs17038921 4 109284961 [T/C] rs7667905 4 109286645 [T/C] rs12374269 4 109288854 [T/C] rs6844729 4 109289367 [A/G] rs17038931 4 109290374 [A/G] rs219457 4 109292368 [T/C] rs11097983 4 109295549 [T/C] rs188720 4 109295714 [T/C] rs17038960 4 109295912 [A/G] rs188721 4 109296917 [T/C] rs219463 4 109298141 [T/C] rs737605 4 109298935 [A/G] rs740053 4 109299202 [A/G] rs13132148 4 109301049 [T/C] rs219467 4 109301111 [A/G] rs17038980 4 109303471 [T/C] rs1452397 4 109305397 [A/G] rs219472 4 109311641 [A/G] rs17039002 4 109312549 [A/G] rs219448 4 109315729 [T/C] rs121967 4 109316327 [A/G] rs219456 4 109320729 [T/G] rs219451 4 109322782 [A/G] rs172666 4 109338471 [T/C] rs6811130 4 109340406 [T/C] rs219481 4 109340680 [T/C] rs17039028 4 109346722 [A/G] rs1377065 4 109349464 [A/G] rs219493 4 109350880 [T/C] rs219500 4 109362923 [A/G] rs11936528 4 109369135 [T/C] rs7667423 4 109372293 [T/C] rs1452401 4 109374717 [A/G] rs719786 4 109396732 [A/G] rs7654972 4 109407499 [T/C] rs1562975 4 109408608 [A/G] rs6838036 4 109411079 [A/C] rs12508024 4 109413413 [A/G] rs1115882 4 109417821 [T/C] rs4996943 4 109439995 [A/G] rs11737760 4 109441230 [A/G] rs17583662 4 109461985 [A/G] NR_026968 RPL34-AS1 Silent rs7688462 4 109465726 [T/C] NR_026968 RPL34-AS1 Silent rs1017432 4 109474255 [T/C] NR_026968 RPL34-AS1 Silent rs7686569 4 109477779 [T/G] NR_026968 RPL34-AS1 EXON Silent rs11734670 4 109486382 [T/C] NR_026968 RPL34-AS1 Silent rs7676871 4 109488632 [T/C] NR_026968 RPL34-AS1 Silent rs17800095 4 109493253 [A/G] NR_026968 RPL34-AS1 Silent rs12646462 4 109517946 [A/C] NR_026968 RPL34-AS1 Silent rs17584310 4 109529238 [T/C] NR_026968 RPL34-AS1 Silent rs1865845 4 109532430 [A/G] NR_026968 RPL34-AS1 Silent rs7691236 4 109536616 [A/C] NR_026968 RPL34-AS1 Silent rs13111981 4 109543642 [A/C] NM_000995,NM_001319236,NM_001319235,NM_033625,NM_001319232,NM_001319234 RPL34,RPL34,RPL34,RPL34,RPL34,RPL34 Silent,Silent,Silent,Silent,Silent,Silent rs767062 4 109549748 [A/G] NM_000995,NM_033625 RPL34,RPL34 Silent,Silent rs11097999 4 109552881 [A/G] rs2880787 4 109553331 [A/G] rs17039171 4 109559063 [A/G] rs1369962 4 109583785 [A/G] NM_001267817,NM_001267818,NM_021227 OSTC,OSTC,OSTC Silent,Silent,Silent rs2575632 4 109586178 [T/C] NM_001267817,NM_001267818,NM_021227 OSTC,OSTC,OSTC Silent,Silent,Silent rs6811564 4 109608132 [T/C] rs6852328 4 109613948 [T/C] rs10029851 4 109628025 [A/C] rs1436506 4 109630951 [T/C] rs2575625 4 109636348 [T/C] rs1812429 4 109642764 [T/G] rs7665658 4 109643002 [T/C] rs2575657 4 109657931 [T/C] rs12710996 4 109658910 [T/C] rs12649328 4 109660715 [T/C] rs4956208 4 109663371 [T/G] NM_001146627,NM_001146590,NM_001331032,NM_031279,NM_001331031,NM_001331033 ETNPPL,ETNPPL,ETNPPL,ETNPPL,ETNPPL,ETNPPL EXON Silent,Silent,Silent,Silent,Silent,Silent rs7663958 4 109664667 [A/C] NM_001146627,NM_001146590,NM_001331032,NM_031279,NM_001331031,NM_001331033 ETNPPL,ETNPPL,ETNPPL,ETNPPL,ETNPPL,ETNPPL Silent,Silent,Silent,Silent,Silent,Silent rs10035050 4 109665016 [A/G] NM_001146627,NM_001146590,NM_001331032,NM_031279,NM_001331031,NM_001331033 ETNPPL,ETNPPL,ETNPPL,ETNPPL,ETNPPL,ETNPPL Silent,Silent,Silent,Silent,Silent,Silent rs1078132 4 109670312 [T/C] NM_001146627,NM_001146590,NM_001331032,NM_031279,NM_001331031,NM_001331033 ETNPPL,ETNPPL,ETNPPL,ETNPPL,ETNPPL,ETNPPL Silent,Silent,Silent,Silent,Silent,Silent rs752303 4 109670626 [A/G] NM_001146627,NM_001146590,NM_001331032,NM_031279,NM_001331031,NM_001331033 ETNPPL,ETNPPL,ETNPPL,ETNPPL,ETNPPL,ETNPPL Silent,Silent,Silent,Silent,Silent,Silent rs1377210 4 109674116 [A/G] NM_001146627,NM_001146590,NM_001331032,NM_031279,NM_001331031,NM_001331033 ETNPPL,ETNPPL,ETNPPL,ETNPPL,ETNPPL,ETNPPL EXON Missense_S213P,Missense_S179P,Missense_S145P,Missense_S185P,Missense_S145P,Missense_S112P rs12108563 4 109684830 [T/C] rs6814067 4 109704907 [T/G] rs6852039 4 109707619 [T/C] rs11732844 4 109707993 [A/G] rs2880902 4 109708479 [A/G] rs1840063 4 109711994 [T/C] rs17039317 4 109714131 [A/C] rs7692671 4 109714155 [A/G] rs9994524 4 109715558 [T/C] rs9631731 4 109722566 [T/C] rs10011045 4 109724292 [T/C] rs1812590 4 109730810 [A/G] rs10026399 4 109734645 [A/G] NR_045756,NM_198721 COL25A1,COL25A1 EXON Silent,Silent rs2305437 4 109734959 [A/G] NR_045756,NM_198721 COL25A1,COL25A1 EXON Silent,Silent rs1452689 4 109750774 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs6829773 4 109754899 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs4956063 4 109759469 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs1349677 4 109762297 [A/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs11098004 4 109766290 [T/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs1563005 4 109767869 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs12642704 4 109772715 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs2198329 4 109774351 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs965935 4 109781788 [A/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs11945189 4 109791707 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs7686077 4 109803577 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs884049 4 109805696 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs10856995 4 109817962 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs7655700 4 109821503 [A/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs12643975 4 109822990 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs17596124 4 109826319 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs1526131 4 109834239 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs12504037 4 109841334 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs17596705 4 109841743 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 EXON Silent,Synonymous_P242P,Synonymous_P238P,Synonymous_P242P rs13104889 4 109843603 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs17531474 4 109863370 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 EXON Silent,Silent,Missense_V183I,Silent rs2881015 4 109870169 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs6853519 4 109880276 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs10009816 4 109884269 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs17039593 4 109888212 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs2194861 4 109889251 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs10024281 4 109890731 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs3863122 4 109898846 [T/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs3863123 4 109898887 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs3863124 4 109898914 [A/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs11098020 4 109903445 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs10516554 4 109922064 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs4547872 4 109926806 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs1648012 4 109928033 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs1405160 4 109931951 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs2081466 4 109938078 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs12502197 4 109945016 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs2194860 4 109948511 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs1648045 4 109948640 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs752673 4 109952249 [T/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs794139 4 109952756 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs794144 4 109953266 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs7672923 4 109954423 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs12648799 4 109957769 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs3108923 4 109970465 [T/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs1863293 4 109975633 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs12331097 4 109980806 [A/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs1425353 4 109981685 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs1895742 4 109987288 [A/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs3113687 4 109987381 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs876365 4 109989467 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs1991219 4 110000675 [T/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs17039766 4 110006432 [A/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs4632736 4 110017206 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs4368681 4 110030410 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs7679372 4 110034004 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs1317984 4 110035050 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs3113727 4 110037163 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs17039896 4 110048492 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs11947505 4 110048604 [T/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs17039902 4 110052853 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs6820892 4 110053143 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs17039914 4 110057072 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs17288525 4 110069083 [A/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs4956247 4 110077762 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs17039993 4 110077899 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs17223850 4 110097265 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs2526434 4 110097567 [T/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs13149803 4 110099651 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs2704102 4 110103485 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs2189708 4 110122500 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs987695 4 110131702 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs10049987 4 110132858 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs2007788 4 110136612 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs4956253 4 110153951 [T/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs17304953 4 110155038 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs12640304 4 110155157 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs17040162 4 110158446 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs17226518 4 110162634 [T/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs7692025 4 110168834 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs7675657 4 110178174 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs7682615 4 110179436 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs7695378 4 110181439 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs4512071 4 110189698 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs1297941 4 110192405 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs1297940 4 110198260 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs917022 4 110200344 [T/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs2346029 4 110207927 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs2214375 4 110209365 [A/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs6820019 4 110211727 [A/G] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs961695 4 110216053 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs6822076 4 110220384 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 Silent,Silent,Silent,Silent rs1859143 4 110223320 [T/C] NR_045756,NM_198721,NM_001256074,NM_032518 COL25A1,COL25A1,COL25A1,COL25A1 EXON Silent,Silent,Silent,Silent rs714586 4 110226406 [T/G] NM_001039778 ZCCHC23 Silent rs13128445 4 110228717 [A/G] NM_001039778 ZCCHC23 Silent rs10005272 4 110250481 [T/G] rs11935942 4 110254092 [T/C] rs13104799 4 110255140 [A/G] rs10031399 4 110278217 [T/C] rs7673867 4 110278483 [A/C] rs1557804 4 110278816 [A/G] rs1859144 4 110283708 [A/G] rs17040364 4 110287592 [A/C] rs6854151 4 110299443 [A/G] rs11098033 4 110324528 [T/C] rs11098035 4 110350409 [T/C] rs17040436 4 110365426 [A/G] NM_001300813,NM_001318085,NM_001042734,NM_001318086,NM_006323 SEC24B,SEC24B,SEC24B,SEC24B,SEC24B Silent,Silent,Silent,Silent,Silent rs6852062 4 110369533 [T/C] NM_001300813,NM_001318085,NM_001042734,NM_001318086,NM_006323 SEC24B,SEC24B,SEC24B,SEC24B,SEC24B Silent,Silent,Silent,Silent,Silent rs10009463 4 110373682 [A/G] NM_001300813,NM_001318085,NM_001042734,NM_001318086,NM_006323 SEC24B,SEC24B,SEC24B,SEC24B,SEC24B Silent,Silent,Silent,Silent,Silent rs1396709 4 110378688 [A/G] NM_001300813,NM_001318085,NM_001042734,NM_001318086,NM_006323 SEC24B,SEC24B,SEC24B,SEC24B,SEC24B Silent,Silent,Silent,Silent,Silent rs9985632 4 110388034 [T/C] NM_001300813,NM_001318085,NM_001042734,NM_001318086,NM_006323 SEC24B,SEC24B,SEC24B,SEC24B,SEC24B Silent,Silent,Silent,Silent,Silent rs10516556 4 110395146 [T/C] NM_001300813,NM_001318085,NM_001042734,NM_001318086,NM_006323 SEC24B,SEC24B,SEC24B,SEC24B,SEC24B Silent,Silent,Silent,Silent,Silent rs10516557 4 110395406 [A/G] NM_001300813,NM_001318085,NM_001042734,NM_001318086,NM_006323 SEC24B,SEC24B,SEC24B,SEC24B,SEC24B Silent,Silent,Silent,Silent,Silent rs6856291 4 110409978 [A/G] NM_001300813,NM_001318085,NM_001042734,NM_001318086,NM_006323 SEC24B,SEC24B,SEC24B,SEC24B,SEC24B Silent,Silent,Silent,Silent,Silent rs6812906 4 110446454 [A/G] NM_001300813,NM_001318085,NM_001042734,NM_001318086,NM_006323 SEC24B,SEC24B,SEC24B,SEC24B,SEC24B Silent,Silent,Silent,Silent,Silent rs10003981 4 110454306 [A/G] NM_001300813,NM_001318085,NM_001042734,NM_001318086,NM_006323 SEC24B,SEC24B,SEC24B,SEC24B,SEC24B Silent,Silent,Silent,Silent,Silent rs17040515 4 110461523 [A/C] NM_001300813,NM_001318085,NM_001042734,NM_001318086,NM_006323 SEC24B,SEC24B,SEC24B,SEC24B,SEC24B EXON Silent,Silent,Silent,Silent,Silent rs3775962 4 110466413 [A/G] rs17040519 4 110466758 [A/C] rs11930142 4 110471581 [T/C] rs6533434 4 110474321 [A/G] rs7687245 4 110486492 [A/C] NM_017918 MCUB Silent rs6831048 4 110491665 [A/C] NM_017918 MCUB Silent rs17619310 4 110496506 [A/G] NM_017918 MCUB Silent rs197203 4 110498602 [A/G] NM_017918 MCUB Silent rs7694402 4 110510080 [A/G] NM_017918 MCUB Silent rs149800 4 110515471 [A/G] NM_017918 MCUB Silent rs197230 4 110515484 [A/G] NM_017918 MCUB Silent rs197212 4 110523044 [A/G] NM_017918 MCUB Silent rs17440077 4 110537567 [A/G] NM_017918 MCUB Silent rs6533438 4 110538429 [A/G] NM_017918 MCUB Silent rs7687878 4 110539442 [A/G] NM_017918 MCUB Silent rs6832174 4 110544696 [T/C] NM_017918 MCUB Silent rs7677585 4 110546567 [T/G] NM_017918 MCUB Silent rs10017480 4 110548394 [T/C] NM_017918 MCUB Silent rs11938222 4 110555678 [A/G] NM_017918 MCUB Silent rs4698773 4 110562936 [A/C] NM_017918 MCUB Silent rs10032323 4 110567473 [A/G] NM_017918 MCUB Silent rs13128388 4 110568156 [T/C] NM_017918 MCUB Silent rs9990765 4 110568711 [T/C] NM_017918 MCUB Silent rs1029452 4 110571181 [T/C] NM_017918 MCUB Silent rs13103963 4 110577363 [T/C] NM_017918 MCUB Silent rs17440280 4 110582100 [T/C] NM_017918 MCUB Silent rs3796911 4 110584287 [A/G] NM_017918 MCUB Silent rs4698776 4 110590821 [A/G] NM_017918 MCUB Silent rs13103167 4 110593460 [A/C] NM_017918 MCUB Silent rs4698780 4 110602430 [T/G] NM_017918 MCUB Silent rs3733611 4 110603784 [T/C] NM_017918 MCUB EXON Synonymous_S166S rs2285712 4 110606713 [T/C] NM_017918 MCUB Silent rs5030606 4 110608967 [A/G] rs3212153 4 110609481 [A/G] rs1800627 4 110613658 [A/G] NM_032992,NR_133012,NM_001226 CASP6,CASP6,CASP6 Silent,Silent,Silent rs2227927 4 110615831 [A/G] NM_032992,NR_133012,NM_001226 CASP6,CASP6,CASP6 EXON Synonymous_A22A,Silent,Synonymous_A111A rs5030674 4 110615839 [T/C] NM_032992,NR_133012,NM_001226 CASP6,CASP6,CASP6 EXON Missense_A20T,Silent,Missense_A109T rs11574696 4 110618907 [T/G] NM_032992,NR_133012,NM_001226 CASP6,CASP6,CASP6 EXON Silent,Silent,Missense_A34E rs5030545 4 110620870 [T/C] NM_032992,NR_133012,NM_001226 CASP6,CASP6,CASP6 Silent,Silent,Silent rs1541373 4 110628894 [T/C] rs3087494 4 110631621 [A/G] NM_030821 PLA2G12A EXON Silent rs28649856 4 110634280 [A/G] NM_030821 PLA2G12A EXON Silent rs2285713 4 110634891 [T/C] NM_030821 PLA2G12A EXON Silent rs2285714 4 110638810 [T/C] NM_030821 PLA2G12A EXON Synonymous_E115E rs2107047 4 110647775 [A/G] NM_030821 PLA2G12A Silent rs10004377 4 110648124 [T/G] NM_030821 PLA2G12A Silent rs2346841 4 110654640 [A/G] rs7439493 4 110656730 [A/G] rs10033900 4 110659067 [T/C] rs551 4 110661937 [A/G] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI EXON Silent,Silent,Silent rs11726949 4 110664630 [T/C] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI Silent,Silent,Silent rs13104777 4 110665481 [T/C] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI Silent,Silent,Silent rs6822976 4 110666292 [A/G] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI Silent,Silent,Silent rs9998151 4 110667345 [T/C] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI Silent,Silent,Silent rs7438961 4 110668651 [A/G] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI Silent,Silent,Silent rs2298749 4 110681505 [T/C] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI EXON Synonymous_S268S,Synonymous_S268S,Synonymous_S268S rs4541508 4 110682487 [T/C] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI Silent,Silent,Silent rs17610314 4 110682953 [A/G] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI Silent,Silent,Silent rs3822272 4 110683550 [T/C] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI Silent,Silent,Silent rs7439356 4 110684744 [T/C] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI Silent,Silent,Silent rs10025263 4 110695751 [A/G] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI Silent,Silent,Silent rs4626205 4 110708517 [A/C] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI Silent,Silent,Silent rs10029485 4 110713964 [A/G] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI Silent,Silent,Silent rs7675460 4 110720588 [A/C] NM_001318057,NM_000204,NM_001331035 CFI,CFI,CFI Silent,Silent,Silent rs884711 4 110726322 [A/C] rs4698790 4 110727560 [T/G] rs4698792 4 110729304 [T/C] rs11930711 4 110734498 [A/G] rs6828254 4 110737549 [A/G] NM_018983,NM_032993 GAR1,GAR1 Silent,Silent rs6533467 4 110738720 [A/G] NM_018983,NM_032993 GAR1,GAR1 Silent,Silent rs4353905 4 110745938 [A/G] rs10000762 4 110747864 [T/C] rs10025706 4 110748205 [A/G] rs12513108 4 110754499 [T/C] NM_006583 RRH Silent rs13150454 4 110756211 [A/G] NM_006583 RRH Silent rs4698795 4 110758769 [A/G] NM_006583 RRH Silent rs7438763 4 110763413 [A/G] NM_006583 RRH Silent rs7681770 4 110765361 [T/G] NM_006583 RRH EXON Silent rs7657133 4 110765372 [A/G] NM_006583 RRH EXON Silent rs6839680 4 110765496 [T/C] NM_006583 RRH EXON Silent rs10024160 4 110765634 [T/G] NM_006583 RRH EXON Silent rs17040904 4 110772711 [T/C] NM_198506 LRIT3 EXON Synonymous_P56P rs4698797 4 110773067 [A/G] NM_198506 LRIT3 EXON Missense_S175N rs10857002 4 110773433 [A/C] NM_198506 LRIT3 Silent rs2078040 4 110779516 [A/G] NM_198506 LRIT3 Silent rs7654660 4 110784379 [A/G] NM_198506 LRIT3 Silent rs17040920 4 110785384 [A/G] NM_198506 LRIT3 Silent rs7679048 4 110786290 [T/C] NM_198506 LRIT3 Silent rs11940838 4 110787993 [A/C] NM_198506 LRIT3 Silent rs2347132 4 110791413 [T/C] NM_198506 LRIT3 EXON Missense_T503M rs9994891 4 110791453 [T/C] NM_198506 LRIT3 EXON Synonymous_T516T rs6830168 4 110792799 [T/C] NM_198506 LRIT3 EXON Silent rs10011256 4 110792907 [A/G] NM_198506 LRIT3 EXON Silent rs11722475 4 110795962 [T/C] rs6847467 4 110800020 [A/G] rs17040963 4 110803807 [T/C] rs9685587 4 110803816 [A/G] rs11937583 4 110808173 [A/G] rs11736783 4 110808321 [T/C] rs7689017 4 110810499 [T/G] rs2024111 4 110812598 [A/G] rs718768 4 110824115 [A/G] rs17316633 4 110825634 [A/G] rs17238095 4 110826275 [T/C] rs4444903 4 110834110 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF EXON Silent,Silent,Silent,Silent rs11568847 4 110834150 [T/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF EXON Silent,Silent,Silent,Silent rs11568849 4 110834537 [A/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF EXON Missense_S16R,Missense_S16R,Missense_S16R,Missense_S16R rs2298978 4 110837667 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs2298982 4 110846796 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs11568889 4 110862637 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs9991664 4 110864533 [T/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF EXON Missense_H151Y,Missense_H151Y,Missense_H151Y,Missense_H151Y rs11568898 4 110864723 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs10470911 4 110865271 [T/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs11568901 4 110865316 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs4698756 4 110866442 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs4698800 4 110866508 [T/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs3796947 4 110870765 [T/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs1024599 4 110875113 [T/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs9992755 4 110882590 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs11568943 4 110883121 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF EXON Missense_R431K,Missense_R431K,Missense_R389K,Missense_R389K rs929446 4 110883344 [T/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs11568961 4 110885743 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs11568970 4 110888855 [T/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs11568978 4 110889909 [T/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs2255355 4 110891543 [A/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs2298989 4 110891673 [T/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs2298991 4 110892012 [T/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs9991367 4 110894301 [T/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs11568993 4 110897315 [T/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF EXON Synonymous_C659C,Synonymous_C659C,Synonymous_C617C,Synonymous_C617C rs11568994 4 110897535 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs2302135 4 110901147 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF EXON Synonymous_A691A,Synonymous_A691A,Synonymous_A649A,Synonymous_A649A rs2237051 4 110901198 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF EXON Missense_M708I,Missense_M708I,Missense_M666I,Missense_M666I rs11569045 4 110908881 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs11569047 4 110909169 [A/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs2298999 4 110911907 [T/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs11569061 4 110913193 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs11569087 4 110916180 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs3822286 4 110925459 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs11569121 4 110929128 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs11569126 4 110929653 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs11569134 4 110931220 [A/G] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF Silent,Silent,Silent,Silent rs3733625 4 110933004 [T/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF EXON Silent,Silent,Silent,Silent rs11569146 4 110933094 [T/C] NM_001963,NM_001178130,NM_001178131,NM_001357021 EGF,EGF,EGF,EGF EXON Silent,Silent,Silent,Silent rs11569163 4 110935225 [T/C] rs17041230 4 110937515 [T/C] rs4698804 4 110940045 [T/C] rs17041245 4 110945256 [T/C] rs720419 4 110945966 [T/C] rs7440841 4 110946249 [A/C] rs6854522 4 110953909 [A/G] rs6845765 4 110958164 [T/C] rs9990430 4 110964272 [T/C] rs10012953 4 110964362 [A/G] rs11098064 4 110966120 [T/C] rs9030 4 110967310 [A/G] rs3813826 4 110967788 [T/G] rs12108641 4 110968599 [T/G] rs28450072 4 110970851 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 EXON Silent,Silent rs7662161 4 110975433 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs7690709 4 110976538 [A/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs17041301 4 110976758 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs9997849 4 110977053 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs12500716 4 110977136 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs1557803 4 110978498 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs17041309 4 110979707 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs17041315 4 110982227 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs12498468 4 110982248 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs17041322 4 110982272 [A/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs17041323 4 110984555 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs16997129 4 110989719 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs11737840 4 110994243 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs2040710 4 110994792 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs6858635 4 110995658 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs10033691 4 110995710 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs2005701 4 110997775 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs11726880 4 111004545 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs34415611 4 111007345 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs10005776 4 111016014 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs3733623 4 111026520 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs10011926 4 111026927 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs6533491 4 111030787 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs1005595 4 111032048 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs1005594 4 111032489 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs1001857 4 111032602 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs11098070 4 111033180 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs1125819 4 111036402 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs1026883 4 111036781 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs2170553 4 111043210 [A/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs10010167 4 111051486 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs6533493 4 111055176 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs11936079 4 111055558 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs7667291 4 111055836 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs6835929 4 111064092 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs4698812 4 111065534 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs4146696 4 111067650 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs6813255 4 111072985 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs11733718 4 111073867 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs2200106 4 111079337 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs2035415 4 111084981 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs17612737 4 111086221 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs10028161 4 111092664 [T/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs10008897 4 111093616 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs1384331 4 111105442 [T/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs13145689 4 111109020 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs6533498 4 111112788 [A/C] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs11098071 4 111117247 [A/G] NM_001130721,NM_024090 ELOVL6,ELOVL6 Silent,Silent rs6824447 4 111120713 [A/G] rs6831073 4 111121841 [A/G] rs4698814 4 111125483 [A/G] rs17041421 4 111126874 [A/G] rs5022521 4 111128587 [T/C] rs12499874 4 111129756 [A/G] rs12510756 4 111132642 [T/C] rs17041448 4 111132948 [A/G] rs4698761 4 111143870 [A/C] rs4698816 4 111144049 [A/G] rs7686686 4 111144505 [T/C] rs4557340 4 111146079 [T/C] rs7697518 4 111151421 [T/C] rs11098072 4 111151810 [A/G] rs13105344 4 111158481 [A/G] rs17041514 4 111164592 [A/G] rs6533505 4 111166848 [T/G] rs7661205 4 111166999 [T/C] rs11735814 4 111168797 [T/C] rs6823387 4 111171406 [T/C] rs10022428 4 111173167 [A/G] rs1482470 4 111173378 [A/G] rs10009070 4 111181565 [T/C] rs7656124 4 111187683 [T/C] rs10516561 4 111191861 [T/G] rs7694909 4 111195127 [A/G] rs17542839 4 111197373 [T/C] rs2713946 4 111197805 [T/C] rs2713949 4 111198328 [T/C] rs417693 4 111211272 [A/G] rs7659944 4 111214289 [A/G] rs11934805 4 111214566 [A/C] rs12510061 4 111214726 [A/G] rs244053 4 111216329 [T/C] rs763298 4 111218256 [A/C] rs244043 4 111227771 [A/C] rs9990445 4 111227913 [A/G] rs244036 4 111231836 [T/C] rs244055 4 111239014 [A/G] rs13113943 4 111241892 [A/G] rs4698832 4 111249625 [A/G] rs10011752 4 111252829 [T/G] rs244019 4 111254360 [T/C] rs244017 4 111255917 [T/G] rs17586996 4 111257452 [T/G] rs244016 4 111257748 [A/G] rs244005 4 111262618 [T/C] rs6851562 4 111265491 [A/G] rs243988 4 111267671 [A/G] rs10027970 4 111268100 [T/C] rs409267 4 111272563 [A/G] rs6836372 4 111275822 [A/G] rs400966 4 111278172 [T/C] rs243981 4 111280757 [T/C] rs243978 4 111281932 [T/C] rs10488888 4 111283708 [T/C] rs243973 4 111286032 [T/C] rs243970 4 111288232 [A/C] rs17625855 4 111288254 [T/C] rs243957 4 111295923 [A/G] rs243952 4 111297688 [A/G] rs10516562 4 111306263 [T/C] rs17041746 4 111313114 [T/G] rs2348205 4 111313570 [A/G] rs1027045 4 111319763 [T/C] rs2129569 4 111321441 [A/G] rs10017096 4 111324679 [A/G] rs12506286 4 111324997 [T/C] rs1879056 4 111335604 [T/C] rs1879057 4 111335722 [T/C] rs9942210 4 111356532 [T/C] rs17008091 4 111363108 [T/C] rs2017368 4 111364167 [T/C] rs6814283 4 111388265 [T/C] rs17041821 4 111392963 [T/C] rs6823980 4 111393691 [A/G] rs1879053 4 111396948 [T/C] rs10004516 4 111398208 [A/G] NM_001977 ENPEP EXON Missense_Q213R rs6847717 4 111401982 [T/C] NM_001977 ENPEP Silent rs2881913 4 111416282 [A/C] NM_001977 ENPEP Silent rs17551860 4 111418814 [A/G] NM_001977 ENPEP Silent rs17041828 4 111419299 [A/G] NM_001977 ENPEP Silent rs939213 4 111420577 [A/G] NM_001977 ENPEP Silent rs11731078 4 111426341 [T/C] NM_001977 ENPEP Silent rs2348433 4 111437127 [A/C] NM_001977 ENPEP Silent rs7356191 4 111437986 [A/G] NM_001977 ENPEP Silent rs670014 4 111454631 [A/G] NM_001977 ENPEP Silent rs557785 4 111462203 [A/C] NM_001977 ENPEP Silent rs478454 4 111463277 [T/C] NM_001977 ENPEP Silent rs9997349 4 111473366 [A/G] NM_001977 ENPEP Silent rs17041900 4 111473485 [T/G] NM_001977 ENPEP Silent rs3796879 4 111476701 [T/C] NM_001977 ENPEP Silent rs2029073 4 111477949 [A/G] NM_001977 ENPEP Silent rs2290105 4 111484143 [T/C] NM_001977 ENPEP EXON Silent rs7682249 4 111485171 [T/G] rs1562640 4 111492369 [A/G] rs1466097 4 111496844 [A/G] rs11721423 4 111501269 [T/C] rs1900829 4 111509740 [A/G] rs1470618 4 111510571 [T/C] rs17553596 4 111520926 [T/G] NR_147203 PANCR Silent rs17041950 4 111521184 [T/C] NR_147203 PANCR Silent rs9790621 4 111530168 [A/G] NR_147203,NR_147204 PANCR,PANCR Silent,Silent rs10024173 4 111538121 [A/G] rs6533526 4 111538827 [A/G] NM_001204398,NM_000325,NM_001204397,NM_153426,NM_001204399,NM_153427 PITX2,PITX2,PITX2,PITX2,PITX2,PITX2 EXON Silent,Silent,Silent,Silent,Silent,Silent rs3796902 4 111540468 [A/G] NM_001204398,NM_000325,NM_001204397,NM_153426,NM_001204399,NM_153427 PITX2,PITX2,PITX2,PITX2,PITX2,PITX2 Silent,Silent,Silent,Silent,Silent,Silent rs2595110 4 111545323 [A/G] NM_001204398,NM_001204397,NM_153426,NM_001204399,NM_153427 PITX2,PITX2,PITX2,PITX2,PITX2 Silent,Silent,Silent,Silent,Silent rs7668322 4 111548596 [T/G] NM_001204398,NM_001204397,NM_153426,NM_001204399,NM_153427 PITX2,PITX2,PITX2,PITX2,PITX2 Silent,Silent,Silent,Silent,Silent rs1448818 4 111570223 [A/C] rs1982360 4 111571042 [T/C] rs12498374 4 111584419 [T/C] rs1992927 4 111598749 [A/G] rs2723296 4 111604483 [A/G] rs2723298 4 111608485 [T/C] rs2723311 4 111622022 [A/G] rs7667461 4 111622134 [A/G] rs969642 4 111625925 [T/C] rs2595093 4 111627356 [A/G] rs2723313 4 111627489 [A/G] rs16997168 4 111629039 [T/C] rs2723316 4 111634287 [T/C] rs10222783 4 111634826 [T/C] rs1448817 4 111641053 [A/G] rs10019689 4 111649869 [A/C] rs11098090 4 111656408 [T/C] rs10027473 4 111664452 [A/G] rs2634073 4 111665783 [T/C] rs2634076 4 111672273 [T/C] rs10516563 4 111677722 [T/G] rs4605724 4 111685081 [A/C] rs6533527 4 111687514 [A/C] rs2723334 4 111688752 [T/C] rs7690874 4 111691077 [A/G] rs2129982 4 111704143 [A/G] rs6817105 4 111705768 [T/C] rs1906602 4 111713323 [T/C] rs13143308 4 111714419 [T/G] rs2220427 4 111714889 [T/C] rs13105878 4 111718147 [A/C] rs11931959 4 111719685 [A/G] rs10033464 4 111720761 [T/G] rs723363 4 111724501 [T/C] rs13141190 4 111728614 [A/G] rs3853441 4 111729740 [T/C] rs4124159 4 111730243 [A/G] rs3853444 4 111734136 [T/C] rs880309 4 111735539 [A/G] rs17042224 4 111738905 [T/G] rs13130446 4 111739156 [T/C] rs10516564 4 111739292 [A/G] rs3866836 4 111745640 [A/G] rs3866838 4 111753815 [T/C] rs3853445 4 111761487 [T/C] rs6838973 4 111765495 [T/C] rs4631108 4 111773867 [A/C] rs10213323 4 111780482 [T/C] rs4033104 4 111783306 [A/G] rs695183 4 111787380 [T/C] rs4833470 4 111787455 [A/G] rs11098092 4 111798201 [A/G] rs542331 4 111798258 [A/G] rs6843250 4 111799417 [T/G] rs577781 4 111804131 [A/G] rs537772 4 111811620 [T/C] rs10488914 4 111812288 [A/G] rs7679158 4 111812327 [A/G] rs536099 4 111812462 [A/G] rs11947581 4 111812531 [A/G] rs17042473 4 111825573 [T/C] rs530794 4 111831051 [A/G] rs17042503 4 111833498 [A/G] rs570048 4 111835687 [T/G] rs17587726 4 111845147 [T/C] rs17587740 4 111846955 [T/C] rs374582 4 111849422 [A/G] rs886840 4 111858116 [A/G] rs1547935 4 111862435 [A/G] rs10004479 4 111866337 [T/C] rs11943026 4 111872144 [T/G] rs13435512 4 111881685 [T/C] rs17042558 4 111889470 [T/C] rs17042561 4 111893066 [T/C] rs7439813 4 111913732 [T/G] rs10002518 4 111927642 [A/G] rs11726961 4 111928603 [A/G] rs6850589 4 111932510 [T/C] rs1010816 4 111934020 [T/G] rs542046 4 111937018 [A/G] rs66751 4 111941688 [A/G] rs1386389 4 111953270 [A/C] rs10024441 4 111956958 [A/G] rs159471 4 111960686 [T/C] rs977013 4 111964082 [T/C] rs6840447 4 111966090 [A/G] rs159463 4 111980281 [T/C] rs159439 4 111984518 [T/G] rs159438 4 111985054 [A/G] rs212282 4 111986708 [T/C] rs190042 4 111986946 [T/C] rs159456 4 111990905 [T/C] rs297012 4 112004589 [T/C] rs439192 4 112024192 [T/G] rs11932853 4 112024388 [T/C] rs159228 4 112050006 [T/C] rs294941 4 112051379 [A/G] rs294942 4 112051824 [T/C] rs10446719 4 112055872 [A/C] rs9884929 4 112060015 [A/C] rs17042789 4 112061855 [A/G] rs12508528 4 112077613 [T/C] rs1601667 4 112082915 [T/C] rs11098102 4 112093354 [T/C] rs7660826 4 112100154 [A/G] rs1546053 4 112126757 [T/G] rs1552445 4 112129311 [T/C] rs17042928 4 112129705 [T/C] rs17042944 4 112131789 [T/C] rs1490913 4 112137828 [A/G] rs17042997 4 112145870 [A/G] rs1490901 4 112157798 [A/G] rs2220490 4 112172938 [A/C] rs11098109 4 112173532 [T/G] rs7669813 4 112176909 [A/G] rs1388152 4 112179424 [T/C] rs7687984 4 112185091 [A/G] rs17043025 4 112192062 [A/G] rs7694111 4 112193351 [T/C] rs17043035 4 112198777 [A/G] rs17576345 4 112201846 [T/C] rs17043046 4 112207191 [A/G] rs11098115 4 112207954 [A/G] rs6826534 4 112208694 [T/C] rs6833281 4 112209616 [T/C] rs1118276 4 112209738 [T/C] rs17576773 4 112217523 [T/C] rs4833619 4 112217944 [T/C] rs17043075 4 112220233 [A/G] rs4834781 4 112220899 [T/C] rs7692766 4 112226088 [A/G] rs7667177 4 112229861 [T/C] rs9307366 4 112233572 [A/G] rs7684254 4 112244790 [A/G] rs12642421 4 112245519 [A/G] rs28661115 4 112246497 [T/C] rs2130816 4 112252039 [A/G] rs11727195 4 112254270 [A/G] rs1352734 4 112264996 [A/G] rs6827570 4 112265165 [A/G] rs1388156 4 112265437 [T/C] rs1388159 4 112272793 [T/G] rs2661762 4 112277270 [A/C] rs1388158 4 112279167 [A/G] rs1847354 4 112288658 [T/C] rs1910452 4 112289444 [A/C] rs12499979 4 112293391 [A/C] rs2714997 4 112293846 [T/C] rs9685906 4 112306505 [T/G] rs1394001 4 112307357 [A/G] rs7669293 4 112312860 [A/G] rs1503666 4 112314841 [T/C] rs4833646 4 112321704 [A/G] rs1110906 4 112323147 [T/C] rs6833355 4 112336798 [A/G] rs1910455 4 112345629 [T/C] rs3105288 4 112371737 [T/C] rs2661781 4 112390143 [A/G] rs2654735 4 112398613 [T/G] rs2661773 4 112405007 [A/C] rs2714992 4 112413651 [T/G] rs924758 4 112419559 [T/C] rs10027375 4 112424765 [T/C] rs1394002 4 112428657 [A/G] rs12498306 4 112462458 [A/G] rs17043348 4 112466269 [A/G] rs1806506 4 112467251 [A/G] rs10001625 4 112476534 [T/C] rs9992389 4 112497952 [T/C] rs4324606 4 112506540 [A/C] rs12648416 4 112510973 [T/C] rs1450782 4 112514407 [T/G] rs6830890 4 112519126 [A/G] rs2717196 4 112521730 [A/G] rs1470716 4 112524605 [A/G] rs10015214 4 112524778 [T/C] rs2597863 4 112530606 [T/C] rs2597875 4 112536566 [T/C] rs980387 4 112538240 [T/C] rs6845692 4 112542699 [T/G] rs2717207 4 112550848 [A/G] rs983966 4 112557798 [A/G] rs2443057 4 112562714 [A/G] rs10025530 4 112568464 [T/C] rs4833869 4 112576171 [A/G] rs10014697 4 112584467 [T/C] rs17043598 4 112587024 [T/C] rs1450781 4 112588951 [T/C] rs6533579 4 112591777 [T/C] rs2597899 4 112628325 [A/G] rs2122602 4 112644433 [T/C] rs326896 4 112669571 [T/C] rs6823743 4 112673539 [A/G] rs326902 4 112676788 [T/C] rs10516579 4 112683523 [T/C] rs12508492 4 112696927 [T/C] rs6815054 4 112712361 [T/C] rs17043938 4 112712718 [A/G] rs12639925 4 112721581 [A/G] rs966055 4 112722748 [T/C] rs326880 4 112729781 [A/G] rs326872 4 112733434 [A/G] rs326866 4 112739250 [A/G] rs7671351 4 112744390 [A/G] rs13128359 4 112756367 [T/C] rs2199342 4 112762156 [T/C] rs400245 4 112771435 [T/C] rs10030563 4 112774334 [T/G] rs10516580 4 112777194 [A/G] rs1395061 4 112793270 [A/C] rs13435138 4 112793563 [A/C] rs6843121 4 112799771 [A/C] rs17627147 4 112805191 [T/C] rs3850475 4 112809145 [A/G] rs6845600 4 112813419 [T/C] rs3913813 4 112824982 [A/G] rs4256285 4 112827769 [A/G] rs227904 4 112829702 [T/C] rs227906 4 112830162 [T/G] rs17589087 4 112844733 [A/G] rs722052 4 112845980 [A/G] rs7678991 4 112847457 [T/C] rs17527615 4 112874121 [A/G] rs2016740 4 112880414 [T/C] rs1981567 4 112885796 [T/C] rs4834106 4 112900775 [T/C] rs6812046 4 112902209 [T/C] rs7654718 4 112905223 [A/G] rs3906726 4 112909713 [T/C] rs7660014 4 112909820 [T/G] rs3850482 4 112914966 [A/C] rs6820458 4 112922517 [T/C] rs3850485 4 112927422 [A/C] rs10488956 4 112929419 [T/C] rs12500823 4 112929836 [A/G] rs7654475 4 112942442 [A/G] rs4404614 4 112971781 [T/C] rs2018700 4 112979568 [A/C] rs12506001 4 112987361 [A/G] rs4240282 4 112995439 [T/G] rs6842261 4 113003174 [T/G] rs9307378 4 113014647 [A/G] rs10004030 4 113019167 [A/G] rs10516583 4 113025264 [A/C] rs7675133 4 113026607 [T/C] rs12644031 4 113032743 [A/G] rs6533596 4 113033220 [A/G] rs1968489 4 113034504 [T/C] rs7699106 4 113035523 [T/C] rs6815972 4 113036309 [A/G] rs6836984 4 113039827 [A/G] rs7682303 4 113042939 [T/C] rs2351234 4 113044027 [A/C] rs1521477 4 113050302 [A/C] rs9995910 4 113055291 [T/C] rs2117917 4 113071518 [T/C] NM_152400 FAM241A Silent rs1040278 4 113079391 [T/C] NM_152400 FAM241A Silent rs11098145 4 113081283 [A/C] NM_152400 FAM241A Silent rs2351236 4 113092380 [T/C] NM_152400 FAM241A Silent rs6835452 4 113099045 [A/G] NM_152400 FAM241A Silent rs10212874 4 113106286 [A/C] NM_152400 FAM241A Silent rs17044316 4 113118666 [A/G] rs4834241 4 113120268 [T/C] rs9994166 4 113123832 [A/G] rs7437464 4 113125894 [T/C] rs1554467 4 113126582 [A/G] rs4834244 4 113150559 [T/C] rs7699435 4 113151732 [T/C] rs17044330 4 113159977 [A/G] NR_136622,NM_001128426,NM_018569 AP1AR,AP1AR,AP1AR Silent,Silent,Silent rs17044338 4 113169092 [A/C] NR_136622,NM_001128426,NM_018569 AP1AR,AP1AR,AP1AR Silent,Silent,Silent rs10026870 4 113174700 [T/C] NR_136622,NM_001128426,NM_018569 AP1AR,AP1AR,AP1AR Silent,Silent,Silent rs3775969 4 113185053 [T/C] NR_136622,NM_001128426,NM_018569 AP1AR,AP1AR,AP1AR Silent,Silent,Silent rs11723375 4 113189512 [T/G] NR_136622,NM_001128426,NM_018569 AP1AR,AP1AR,AP1AR EXON Silent,Nonsense_E253X,Nonsense_E286X rs6836717 4 113194675 [A/G] rs17604169 4 113195610 [A/G] rs3822289 4 113196545 [A/G] rs3202899 4 113196906 [T/C] NM_052864 TIFA EXON Silent rs701759 4 113199075 [A/G] NM_052864 TIFA EXON Synonymous_Y166Y rs12510189 4 113200382 [T/C] NM_052864 TIFA Silent rs10003654 4 113204153 [A/G] NM_052864 TIFA Silent rs17604670 4 113207277 [T/C] rs17627616 4 113214531 [T/C] rs17627730 4 113232651 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs17044408 4 113239980 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs6839324 4 113240529 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs6810537 4 113243265 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs12648308 4 113243456 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs1544382 4 113244313 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs4834259 4 113244979 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs17044418 4 113246438 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs2351451 4 113246972 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs10018567 4 113247435 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs2051776 4 113248536 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs4834262 4 113251247 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs6829831 4 113251677 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs2351454 4 113260465 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs17528404 4 113262777 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs2240033 4 113264524 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs11098152 4 113269731 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs6828630 4 113272049 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs4834267 4 113278511 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs1009475 4 113280747 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs4834269 4 113281951 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs2097745 4 113282802 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs1859140 4 113290045 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs7694057 4 113293314 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs2023824 4 113298305 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs2023825 4 113302357 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs7673053 4 113302869 [T/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs4833406 4 113304812 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs2051777 4 113306879 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs965013 4 113310981 [A/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs7664678 4 113311741 [T/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs2882661 4 113317475 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs2351458 4 113317583 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs7663969 4 113320553 [A/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs13104183 4 113323634 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs6838405 4 113327945 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs7687819 4 113329345 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs7688190 4 113329465 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs17628268 4 113330772 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs17044631 4 113330940 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs6811550 4 113331585 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs6829461 4 113339161 [T/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs7686496 4 113341588 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs7686711 4 113341721 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs2106988 4 113343224 [T/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs11733852 4 113344203 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs7658978 4 113344564 [A/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs6533616 4 113345147 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 EXON Missense_N97D,Missense_N175D,Missense_N175D rs916868 4 113346714 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs10017209 4 113346996 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs12649485 4 113350665 [A/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs2074388 4 113352397 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 EXON Missense_G487D,Missense_G565D,Missense_G565D rs13148353 4 113352628 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 EXON Missense_H564R,Missense_H642R,Missense_H642R rs2074379 4 113352899 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 EXON Missense_M654I,Missense_M732I,Missense_M732I rs11726117 4 113353285 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 EXON Missense_M783T,Missense_M861T,Missense_M861T rs2074380 4 113353311 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 EXON Missense_G792S,Missense_G870S,Missense_G870S rs2074381 4 113353449 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 EXON Missense_N838D,Missense_N916D,Missense_N916D rs13110304 4 113354150 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs17628432 4 113356927 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs2023828 4 113356961 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 Silent,Silent,Silent rs231247 4 113359703 [A/G] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 EXON Synonymous_R1006R,Synonymous_R1084R,Synonymous_R1084R rs11730442 4 113362463 [T/C] NM_001253884,NM_025144,NM_001102406 ALPK1,ALPK1,ALPK1 EXON Silent,Silent,Silent rs231259 4 113370913 [A/G] rs231263 4 113372448 [A/G] rs17444829 4 113373974 [A/G] rs6815237 4 113374323 [T/C] rs118182 4 113374354 [A/G] rs17590516 4 113375494 [A/C] rs2074384 4 113377758 [A/G] rs879068 4 113379501 [T/C] rs7662734 4 113380119 [A/C] rs28806888 4 113382048 [T/C] rs1486860 4 113393443 [T/C] rs17044746 4 113406671 [A/G] rs11936846 4 113409270 [A/G] rs7699752 4 113415402 [T/C] rs1038560 4 113425609 [T/C] rs12641188 4 113430752 [T/C] rs6848238 4 113433294 [T/C] rs2351760 4 113434057 [T/G] rs1994376 4 113443282 [T/C] NM_001350601 LOC105377372 Silent rs2129405 4 113447137 [T/C] NM_001350601 LOC105377372 Silent rs10001894 4 113454932 [A/G] NM_001350601 LOC105377372 Silent rs11726579 4 113459405 [T/C] NM_001350601 LOC105377372 Silent rs13106629 4 113459416 [T/C] NM_001350601 LOC105377372 Silent rs1486865 4 113465651 [A/G] NM_001350601,NM_018392,NM_001350397 LOC105377372,ZGRF1,ZGRF1 Silent,Silent,Silent rs1486864 4 113465766 [T/G] NM_001350601,NM_018392,NM_001350397 LOC105377372,ZGRF1,ZGRF1 Silent,Silent,Silent rs12054589 4 113465971 [A/G] NM_001350601,NM_018392,NM_001350397 LOC105377372,ZGRF1,ZGRF1 Silent,Silent,Silent rs13144672 4 113472958 [T/C] NM_018392,NM_001350397 ZGRF1,ZGRF1 Silent,Silent rs17605622 4 113482146 [A/G] NM_018392,NM_001350397 ZGRF1,ZGRF1 EXON Missense_S1568L,Missense_S1510L rs10516588 4 113490213 [A/G] NM_018392,NM_001350397 ZGRF1,ZGRF1 Silent,Silent rs6533629 4 113494607 [A/G] NM_018392,NM_001350397 ZGRF1,ZGRF1 Silent,Silent rs3828539 4 113505203 [A/G] NM_018392,NM_001350397 ZGRF1,ZGRF1 EXON Missense_I1410T,Missense_I1352T rs11938673 4 113511629 [A/G] NM_018392,NM_001350397 ZGRF1,ZGRF1 Silent,Silent rs7676983 4 113513938 [T/C] NM_018392,NM_001350397 ZGRF1,ZGRF1 Silent,Silent rs11724428 4 113519607 [A/G] NM_018392,NM_001350397 ZGRF1,ZGRF1 Silent,Silent rs17669218 4 113524723 [A/G] NM_018392,NM_001350397 ZGRF1,ZGRF1 EXON Missense_T978I,Silent rs4834293 4 113528624 [T/C] NM_018392,NM_001350397 ZGRF1,ZGRF1 Silent,Silent rs9993534 4 113533796 [T/C] NM_018392,NM_001350397 ZGRF1,ZGRF1 Silent,Silent rs11735645 4 113534172 [A/G] NM_018392,NM_001350397 ZGRF1,ZGRF1 Silent,Silent rs10002557 4 113538280 [A/G] NM_018392,NM_001350397 ZGRF1,ZGRF1 Silent,Silent rs7696816 4 113539969 [T/C] NM_018392,NM_001350397 ZGRF1,ZGRF1 EXON Missense_N410S,Missense_N410S rs1565010 4 113544142 [T/C] NM_018392,NM_001350397 ZGRF1,ZGRF1 Silent,Silent rs1471880 4 113546107 [T/G] NM_018392,NM_001350397 ZGRF1,ZGRF1 Silent,Silent rs12054518 4 113549989 [A/G] NM_018392,NM_001350397 ZGRF1,ZGRF1 Silent,Silent rs17044862 4 113557224 [A/C] NM_018392,NM_001350397 ZGRF1,ZGRF1 Silent,Silent rs13146963 4 113558602 [A/G] NM_016648,NM_001267039,NR_049768 LARP7,LARP7,LARP7 Silent,Silent,Silent rs12171477 4 113570279 [A/G] NM_016648,NM_001267039,NR_049768,NM_015454,NR_146092 LARP7,LARP7,LARP7,LARP7,LOC109864269 Silent,Silent,Silent,Silent,Silent rs7656819 4 113570885 [T/C] NM_016648,NM_001267039,NR_049768,NM_015454,NR_146092 LARP7,LARP7,LARP7,LARP7,LOC109864269 Silent,Silent,Silent,Silent,Silent rs6533631 4 113578266 [A/G] NM_016648,NM_001267039,NR_049768,NM_015454 LARP7,LARP7,LARP7,LARP7 Silent,Silent,Silent,Silent rs1129065 4 113578609 [T/C] NM_016648,NM_001267039,NR_049768,NM_015454 LARP7,LARP7,LARP7,LARP7 EXON Silent,Silent,Silent,Silent rs12644868 4 113579162 [T/C] rs11732944 4 113588417 [T/C] rs7664015 4 113609023 [T/C] rs11731671 4 113622050 [T/C] rs11946967 4 113637288 [T/C] NM_001354269 ANK2 Silent rs10021207 4 113658555 [T/C] NM_001354269 ANK2 Silent rs6855396 4 113674445 [A/G] NM_001354269 ANK2 Silent rs7654314 4 113685804 [T/C] NM_001354269 ANK2 Silent rs17607420 4 113698005 [T/G] NM_001354269 ANK2 Silent rs11098171 4 113710173 [T/C] NM_001354269 ANK2 Silent rs6829775 4 113719791 [T/C] NM_001354269 ANK2 Silent rs6533648 4 113722291 [A/G] NM_001354269 ANK2 Silent rs17044978 4 113723181 [T/G] NM_001354269 ANK2 Silent rs10434020 4 113724018 [T/C] NM_001354269 ANK2 Silent rs10433899 4 113724108 [A/G] NM_001354269 ANK2 Silent rs17044986 4 113724181 [T/C] NM_001354269 ANK2 Silent rs11732297 4 113737479 [A/G] NM_001354269 ANK2 Silent rs6851781 4 113740351 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10516590 4 113762103 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10013796 4 113765546 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12511494 4 113770535 [A/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11098178 4 113772458 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17672142 4 113775868 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17672170 4 113775901 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1448221 4 113779891 [T/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17045073 4 113781667 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs895763 4 113782926 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7657978 4 113784482 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6835163 4 113789510 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4834308 4 113808126 [A/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17045113 4 113817332 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12513140 4 113817807 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7675254 4 113825869 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10016365 4 113830885 [A/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7680555 4 113835185 [T/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4404544 4 113858241 [A/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10015915 4 113866368 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12506747 4 113866381 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9996317 4 113867271 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7678728 4 113868607 [T/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6844883 4 113903796 [A/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6820742 4 113915647 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12503954 4 113916575 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6818050 4 113918544 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1354680 4 113918577 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6812106 4 113921105 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7655703 4 113921253 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6833846 4 113924858 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2174558 4 113927365 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7687726 4 113931773 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1506064 4 113935712 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10014072 4 113948790 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13103796 4 113948864 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10155397 4 113951572 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17045384 4 113951743 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13115459 4 113953383 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1395114 4 113953581 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12504906 4 113954301 [T/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1354681 4 113954926 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10015472 4 113960961 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10015551 4 113961039 [T/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7654153 4 113963746 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs716051 4 113964288 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs313938 4 113967494 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs313937 4 113967603 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17045462 4 113967942 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6856101 4 113968160 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs313936 4 113968893 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13128057 4 113969404 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7663732 4 113969945 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1026975 4 113971374 [T/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs313942 4 113972856 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs931838 4 113973952 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10007543 4 113976831 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs313985 4 113978279 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs313980 4 113981730 [A/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs313979 4 113981777 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs678035 4 113986740 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs632895 4 113988513 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs689117 4 113989119 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs582050 4 113989326 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2279891 4 113991016 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs884555 4 113998638 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2135354 4 114001887 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12500552 4 114008326 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7656666 4 114009586 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs649022 4 114009885 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6819998 4 114010341 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10029516 4 114011088 [T/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17045537 4 114013008 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs592670 4 114013286 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7683186 4 114013698 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17045555 4 114014365 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs684932 4 114014463 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17476342 4 114016236 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs626267 4 114016978 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17476377 4 114017352 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs695002 4 114017964 [A/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6851877 4 114020087 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs313949 4 114021093 [A/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs313956 4 114023849 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs313958 4 114024092 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9759975 4 114025922 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1385662 4 114026519 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4834315 4 114027334 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7679106 4 114030580 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11731561 4 114032596 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7699082 4 114033802 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17045612 4 114035610 [A/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1506059 4 114037216 [T/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10022885 4 114038963 [A/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11945663 4 114041256 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12502247 4 114044885 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1506063 4 114047406 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13149379 4 114051112 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10003143 4 114052710 [A/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7664927 4 114058373 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17676256 4 114061536 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10020548 4 114062948 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10021192 4 114063451 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17579878 4 114066333 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3112980 4 114067139 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13146022 4 114068831 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11942983 4 114069248 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17482885 4 114078457 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10516593 4 114078812 [A/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13134375 4 114078931 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17590572 4 114080240 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17590593 4 114082021 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4627864 4 114082323 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7697503 4 114086121 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs404950 4 114086242 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6814622 4 114087355 [A/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4833422 4 114089743 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs399754 4 114092317 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6858425 4 114105776 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4834321 4 114108991 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11933707 4 114109593 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2285710 4 114117472 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs967099 4 114118650 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6533674 4 114122971 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11943237 4 114127850 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17629019 4 114135827 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs362492 4 114139428 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs362503 4 114164585 [T/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs362496 4 114168845 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29436 4 114171605 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29413 4 114186005 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29401 4 114193571 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17629353 4 114194411 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29394 4 114197064 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29331 4 114201136 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29382 4 114201353 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29372 4 114204009 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 EXON Missense_N617S,Missense_N633S,Missense_N666S,Missense_N666S,Missense_N633S,Missense_N666S,Missense_N666S,Missense_N666S,Missense_N666S,Missense_N666S,Missense_N658S,Missense_N658S,Missense_N633S,Missense_N592S,Missense_N666S,Missense_N666S,Missense_N658S,Missense_N625S,Missense_N658S,Missense_N666S,Missense_N666S,Missense_N658S,Missense_N658S,Missense_N673S,Missense_N625S,Missense_N687S,Missense_N687S,Missense_N621S,Missense_N654S,Missense_N687S,Missense_N687S,Missense_N687S,Missense_N702S,Missense_N687S,Missense_N687S,Missense_N687S,Missense_N687S,Missense_N654S,Missense_N687S,Missense_N702S,Missense_N702S,Missense_N702S,Missense_N702S,Missense_N702S rs29368 4 114204916 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29327 4 114207666 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29362 4 114208433 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29324 4 114211892 [T/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3025714 4 114216222 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3025713 4 114216407 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29306 4 114216903 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29305 4 114216924 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29319 4 114217997 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29302 4 114224592 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs29314 4 114224764 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3025705 4 114228154 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6837523 4 114231125 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10020183 4 114235039 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10023495 4 114236227 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7676554 4 114248543 [A/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6834212 4 114248666 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11940206 4 114249897 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3736575 4 114257201 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 EXON Synonymous_R1122R,Synonymous_R1106R,Synonymous_R1139R,Synonymous_R1150R,Synonymous_R1118R,Synonymous_R1171R,Synonymous_R1176R,Synonymous_R1172R,Synonymous_R1171R,Synonymous_R1183R,Synonymous_R1131R,Synonymous_R1131R,Synonymous_R1118R,Synonymous_R1065R,Synonymous_R1139R,Synonymous_R1172R,Synonymous_R1131R,Synonymous_R1098R,Synonymous_R1126R,Synonymous_R1184R,Synonymous_R1183R,Synonymous_R1138R,Synonymous_R1131R,Synonymous_R1146R,Synonymous_R1098R,Synonymous_R1193R,Synonymous_R1205R,Synonymous_R1093R,Synonymous_R1139R,Synonymous_R1192R,Synonymous_R1160R,Synonymous_R1192R,Synonymous_R1208R,Synonymous_R1159R,Synonymous_R1193R,Synonymous_R1197R,Synonymous_R1160R,Synonymous_R1127R,Synonymous_R1192R,Synonymous_R1186R,Synonymous_R1207R,Synonymous_R1207R,Synonymous_R1219R,Synonymous_R1208R,Synonymous_R376R,Synonymous_R381R,Synonymous_R369R,Synonymous_R381R,Synonymous_R369R rs2272230 4 114260538 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs28377576 4 114276880 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Missense_V2369A,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3733616 4 114277041 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Missense_A2423T,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3733617 4 114278277 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Missense_P2835S,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10013743 4 114279422 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Synonymous_E3216E,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11930964 4 114285321 [T/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2293324 4 114294308 [T/C] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 EXON Synonymous_H1735H,Synonymous_H1719H,Synonymous_H1752H,Synonymous_H1763H,Synonymous_H1731H,Synonymous_H1815H,Synonymous_H1789H,Synonymous_H1785H,Synonymous_H1784H,Synonymous_H1796H,Synonymous_H1744H,Synonymous_H1744H,Synonymous_H1731H,Synonymous_H1678H,Synonymous_H1752H,Synonymous_H1816H,Synonymous_H1744H,Synonymous_H1711H,Synonymous_H1759H,Synonymous_H1797H,Synonymous_H1827H,Synonymous_H1751H,Synonymous_H1744H,Synonymous_H1759H,Synonymous_H1711H,Synonymous_H3891H,Synonymous_H1849H,Synonymous_H1706H,Synonymous_H1752H,Synonymous_H1805H,Synonymous_H1804H,Synonymous_H1805H,Synonymous_H1821H,Synonymous_H1772H,Synonymous_H1806H,Synonymous_H1810H,Synonymous_H1773H,Synonymous_H1740H,Synonymous_H1836H,Synonymous_H1799H,Synonymous_H1820H,Synonymous_H1851H,Synonymous_H1832H,Synonymous_H1821H,Synonymous_H989H,Synonymous_H994H,Synonymous_H982H,Synonymous_H994H,Synonymous_H982H rs11946150 4 114295540 [A/G] NM_001354269,NM_001354257,NM_001354262,NM_001354272,NM_001354270,NM_001354244,NM_001354254,NM_001354255,NM_001354256,NM_001354252,NM_001354249,NM_001354266,NM_001354253,NM_001354277,NM_001354275,NM_001354243,NM_001354276,NM_001354260,NM_001354274,NM_001127493,NM_001354239,NM_001354264,NM_001354267,NM_001354261,NM_001354271,NM_001148,NM_001354232,NM_001354273,NM_001354245,NM_001354246,NM_001354228,NM_001354265,NM_001354241,NM_001354236,NM_020977,NM_001354225,NM_001354258,NM_001354268,NM_001354235,NM_001354230,NM_001354242,NM_001354231,NM_001354237,NM_001354240,NM_001354280,NM_001354279,NM_001354278,NM_001354282,NM_001354281 ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2,ANK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6826949 4 114305184 [T/C] rs1534093 4 114307861 [T/C] rs6533680 4 114309577 [T/C] rs6846326 4 114311645 [T/C] rs17580458 4 114312389 [T/C] rs2037673 4 114314698 [T/C] rs13130205 4 114315944 [T/C] rs11098192 4 114318689 [A/G] rs7664824 4 114329115 [A/C] rs10008952 4 114330615 [T/G] rs10015062 4 114332302 [A/G] rs1525004 4 114332705 [A/G] rs17676757 4 114334319 [A/G] rs13129231 4 114352881 [A/G] rs17046034 4 114354856 [T/G] rs1554668 4 114357262 [A/G] rs7658972 4 114358532 [T/C] rs17620306 4 114360599 [A/G] rs6533687 4 114365275 [A/G] rs13117519 4 114369065 [T/C] rs17676882 4 114373068 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3733619 4 114373255 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10031387 4 114377928 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1880529 4 114379379 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1524998 4 114379548 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1525000 4 114384869 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17046076 4 114389198 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6835747 4 114391404 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs916874 4 114392393 [A/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6842886 4 114392629 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2158196 4 114416596 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11098193 4 114429407 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D EXON Silent,Silent,Synonymous_S334S,Silent,Silent,Silent,Silent,Silent,Silent,Synonymous_S334S,Silent,Silent,Silent,Silent,Silent,Synonymous_S334S,Silent,Silent,Silent,Synonymous_S334S,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Synonymous_S334S,Synonymous_S334S,Silent,Silent rs17046126 4 114432073 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17630012 4 114432254 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3815072 4 114435877 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6533691 4 114437456 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17046152 4 114437876 [T/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17531026 4 114439090 [A/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11938486 4 114449719 [A/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13133676 4 114450380 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4240286 4 114452724 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17592440 4 114472402 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10027475 4 114477154 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11728021 4 114478653 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7665102 4 114505498 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17447193 4 114506450 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17046279 4 114512213 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7681248 4 114520105 [A/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10025791 4 114524255 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10033037 4 114527882 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9307393 4 114533473 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10488958 4 114534723 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6826859 4 114543214 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10000775 4 114546689 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10023113 4 114546704 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs916913 4 114548301 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1468248 4 114551521 [T/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17630730 4 114551579 [A/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2189363 4 114555661 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12510043 4 114559741 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12512019 4 114561123 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10488959 4 114561733 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17593100 4 114569517 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12506881 4 114572090 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17046372 4 114573947 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6845568 4 114581207 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2107172 4 114585800 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12512765 4 114588367 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1011973 4 114593466 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6827138 4 114594271 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7660775 4 114611948 [A/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4475149 4 114616823 [A/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs764830 4 114617815 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs987694 4 114618602 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7687511 4 114621830 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6533711 4 114626186 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6842343 4 114626620 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1978139 4 114628988 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2040742 4 114631347 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2107170 4 114635044 [T/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9993234 4 114635433 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11098200 4 114635782 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17636449 4 114653664 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4834354 4 114664962 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10488961 4 114665832 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6812422 4 114671843 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17593614 4 114674498 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10006113 4 114678642 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114,NM_001321592 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10018022 4 114678786 [T/C] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114,NM_001321592 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4141007 4 114679682 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114,NM_001321592 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11731775 4 114682714 [A/G] NM_001321583,NM_001321578,NM_001321568,NM_001321566,NM_001321585,NM_001221,NM_001321577,NM_001321580,NM_001321581,NM_001321582,NM_001321586,NM_001321569,NM_001321584,NM_001321576,NM_001321589,NM_001321591,NM_172128,NM_001321590,NM_172127,NM_001321587,NM_001321570,NM_001321579,NM_001321588,NM_001321567,NM_001321575,NM_001321574,NM_001321571,NM_001321572,NM_001321573,NM_172129,NM_172115,NM_172114,NM_001321592 CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D,CAMK2D EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11935493 4 114690439 [A/G] rs7676980 4 114692396 [T/C] rs1557815 4 114696373 [A/G] rs17046474 4 114697137 [A/C] rs1476569 4 114698696 [A/G] rs7662446 4 114702819 [A/G] rs11945240 4 114703071 [A/G] rs10461151 4 114703773 [A/G] rs17532826 4 114703967 [A/G] rs13134836 4 114709273 [T/C] rs11731601 4 114710145 [A/G] rs1081010 4 114732529 [A/G] rs11940349 4 114734812 [A/G] rs4446309 4 114736267 [T/C] rs10010935 4 114741032 [T/C] rs7699538 4 114741276 [A/G] rs7659107 4 114742249 [A/G] rs4396990 4 114742355 [T/G] rs11730230 4 114742637 [T/C] rs4345183 4 114748150 [T/C] rs7684832 4 114751650 [A/G] rs11939599 4 114751776 [A/G] rs9918007 4 114752809 [T/C] rs13126791 4 114754302 [T/G] rs4426777 4 114759474 [A/G] rs4834359 4 114762343 [A/G] rs6836841 4 114768317 [A/G] rs6816415 4 114772555 [T/C] rs13142831 4 114797011 [A/C] rs7437325 4 114800468 [T/G] rs7693734 4 114800812 [T/G] rs13136741 4 114803632 [T/C] rs7674158 4 114816474 [T/C] rs2374218 4 114816990 [T/C] rs6816611 4 114821256 [T/C] rs2374216 4 114822485 [A/G] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ EXON Silent,Silent,Silent rs17620575 4 114827301 [A/G] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs6822455 4 114830955 [T/C] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs6822640 4 114830987 [T/C] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs6533728 4 114833153 [T/G] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs6533729 4 114833290 [A/G] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs6834673 4 114837989 [A/G] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs12645879 4 114842742 [T/C] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs2374196 4 114854312 [T/C] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs7437812 4 114855353 [T/G] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs11729278 4 114855972 [T/G] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs10012647 4 114856627 [T/C] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs766183 4 114864332 [T/C] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs4364328 4 114865091 [T/C] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs11098213 4 114867878 [T/G] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs10012206 4 114877120 [T/C] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs11098218 4 114882556 [T/C] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs728313 4 114884901 [A/G] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs2374219 4 114885155 [T/C] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs17677558 4 114893337 [A/C] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs12505253 4 114898691 [A/C] NM_024590,NM_001354211,NM_001354210 ARSJ,ARSJ,ARSJ Silent,Silent,Silent rs17677630 4 114905001 [T/G] rs17581675 4 114914110 [A/G] rs4833439 4 114938478 [A/G] rs2374223 4 114942909 [A/C] rs882308 4 114946868 [A/G] rs6533743 4 114957205 [A/G] rs7440732 4 114957962 [A/G] rs13112787 4 114958543 [A/C] rs10020382 4 114985792 [T/C] rs6835349 4 115005026 [T/C] rs17046808 4 115013043 [T/C] rs17621440 4 115016497 [T/C] rs11098226 4 115023489 [A/C] rs10023031 4 115030276 [T/C] rs7340953 4 115041483 [A/G] rs4834387 4 115044037 [T/C] rs1497606 4 115047815 [A/C] rs1497591 4 115059118 [A/G] rs1112496 4 115075724 [A/G] rs1497590 4 115078294 [T/C] rs6832117 4 115084166 [T/C] rs1909020 4 115091159 [T/C] rs1497586 4 115095176 [A/G] rs6851287 4 115101499 [T/C] rs1002287 4 115113997 [T/C] rs13128386 4 115134768 [T/C] rs1497595 4 115146328 [T/C] rs11732278 4 115147720 [A/G] rs11944255 4 115149454 [A/G] rs12513381 4 115151872 [A/G] rs1603622 4 115161980 [A/G] rs2646653 4 115163958 [T/C] rs2725520 4 115167948 [A/C] rs12499919 4 115171607 [T/G] rs9998695 4 115172667 [T/C] rs13134083 4 115196903 [A/G] rs4289508 4 115198045 [T/C] rs11947200 4 115199110 [T/C] rs9790620 4 115223284 [A/C] rs4549468 4 115225571 [A/G] rs4597902 4 115227215 [T/G] rs12644990 4 115239529 [A/G] rs12498367 4 115240188 [A/G] rs11098233 4 115242791 [T/G] rs11098234 4 115243741 [T/G] rs10034750 4 115245137 [T/G] rs11098236 4 115250531 [T/G] rs17046991 4 115251586 [A/G] rs4444907 4 115253765 [T/G] rs10516601 4 115255278 [A/G] rs2353563 4 115264835 [A/G] rs4418044 4 115264948 [T/C] rs7667542 4 115271601 [T/G] rs4455493 4 115283928 [T/C] rs4458522 4 115287331 [T/C] rs4989308 4 115289204 [A/G] rs12643524 4 115292482 [A/C] rs4834400 4 115299073 [A/G] rs10015260 4 115304003 [T/C] rs4451001 4 115305849 [T/C] rs12511321 4 115308760 [T/C] rs13122061 4 115313167 [A/G] rs1962495 4 115313315 [T/G] rs4834401 4 115315128 [A/G] rs6843850 4 115316659 [A/G] rs11935578 4 115316768 [T/G] rs4834403 4 115318983 [A/G] rs4440296 4 115319437 [A/G] rs4240294 4 115320145 [T/C] rs4561982 4 115321016 [T/C] rs10857025 4 115327659 [T/C] rs4446396 4 115329332 [A/G] rs4627931 4 115329808 [T/C] rs13120563 4 115339308 [T/C] rs1841432 4 115359532 [T/C] rs1460775 4 115368816 [T/C] rs13434798 4 115370762 [T/C] rs7660554 4 115374527 [A/G] rs4834411 4 115381844 [A/G] rs2388996 4 115385540 [T/C] rs6819276 4 115392483 [A/C] rs1870653 4 115398200 [A/C] rs10857027 4 115399738 [A/G] rs1460770 4 115405345 [A/C] rs11722041 4 115411284 [T/C] rs4833457 4 115412047 [A/G] rs9995562 4 115412233 [A/G] rs6839599 4 115415910 [A/G] rs11936644 4 115421345 [A/G] rs6839694 4 115423197 [A/G] rs2100782 4 115451608 [A/G] rs11938586 4 115458057 [T/C] rs11938628 4 115458168 [T/C] rs1903364 4 115462264 [T/C] rs10516603 4 115467459 [A/G] rs10017302 4 115484827 [A/G] rs11098258 4 115485684 [A/G] rs17678871 4 115490751 [A/C] rs17678877 4 115490786 [A/C] rs12504058 4 115499117 [A/G] rs12650546 4 115499674 [T/C] rs17047249 4 115506203 [A/G] rs11734905 4 115513240 [T/C] rs7436074 4 115514975 [A/G] rs4130705 4 115530635 [A/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114 UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent rs4585328 4 115534816 [T/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114 UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent rs9685397 4 115541961 [T/C] NM_001128174,NM_001322113,NM_001322112,NM_001322114 UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent rs4148254 4 115544713 [T/C] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 EXON Missense_P226L,Missense_P226L,Missense_P226L,Missense_P226L,Missense_P226L rs6851610 4 115544714 [A/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 EXON Synonymous_P226P,Synonymous_P226P,Synonymous_P226P,Synonymous_P226P,Synonymous_P226P rs4148255 4 115544777 [A/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 EXON Synonymous_A247A,Synonymous_A247A,Synonymous_A247A,Synonymous_A247A,Synonymous_A247A rs4240295 4 115550112 [A/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs7677294 4 115554439 [A/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs6533803 4 115558241 [T/C] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs7699381 4 115559137 [T/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs7675420 4 115559446 [A/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs4585329 4 115560225 [T/C] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs10026197 4 115564669 [A/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs13152031 4 115565659 [A/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs4277792 4 115566754 [T/C] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs4377607 4 115570238 [T/C] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs10008981 4 115571345 [G/C] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs7679466 4 115572391 [A/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs6834278 4 115577040 [A/C] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs6813821 4 115581365 [A/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs4834426 4 115583723 [T/C] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs13148827 4 115584352 [A/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs6811122 4 115585997 [A/C] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs4833463 4 115586696 [A/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs6831964 4 115589159 [T/C] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs11098261 4 115589302 [A/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 EXON Missense_I368M,Missense_I368M,Missense_I368M,Missense_I368M,Missense_I368M rs11930035 4 115590789 [T/C] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs6815181 4 115595647 [T/C] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs7686301 4 115596092 [A/G] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 Silent,Silent,Silent,Silent,Silent rs9996273 4 115597453 [T/C] NM_001128174,NM_001322113,NM_001322112,NM_001322114,NM_003360 UGT8,UGT8,UGT8,UGT8,UGT8 EXON Silent,Silent,Silent,Silent,Silent rs4834428 4 115605064 [A/G] rs11098263 4 115607637 [A/G] rs6843689 4 115636783 [A/G] rs4269197 4 115638209 [T/G] rs12510781 4 115640581 [A/G] rs7700052 4 115656533 [A/G] rs6533817 4 115665320 [T/C] rs6842323 4 115666470 [A/G] rs4833467 4 115667187 [A/G] rs4286532 4 115672966 [A/C] rs4834440 4 115678239 [A/G] rs4834442 4 115681827 [A/G] rs11723161 4 115688354 [T/C] rs4508906 4 115692870 [A/G] rs4356926 4 115697774 [T/C] rs10019763 4 115701304 [T/C] rs4376167 4 115720115 [T/G] rs4574434 4 115739428 [T/C] rs6843860 4 115749005 [T/C] NM_022569 NDST4 EXON Synonymous_S862S rs12648047 4 115751064 [T/C] NM_022569 NDST4 Silent rs11098270 4 115755760 [T/C] NM_022569 NDST4 Silent rs10022934 4 115769330 [A/G] NM_022569 NDST4 Silent rs10000924 4 115769497 [A/G] NM_022569 NDST4 Silent rs13120543 4 115786656 [T/C] NM_022569 NDST4 Silent rs17486233 4 115787479 [A/G] NM_022569 NDST4 Silent rs7665509 4 115788728 [A/G] NM_022569 NDST4 Silent rs17047419 4 115790672 [A/G] NM_022569 NDST4 Silent rs11938588 4 115813013 [A/G] NM_022569 NDST4 Silent rs11945934 4 115823991 [T/G] NM_022569 NDST4 Silent rs7694381 4 115829615 [T/C] NM_022569 NDST4 Silent rs7675371 4 115829919 [A/G] NM_022569 NDST4 Silent rs17486477 4 115844385 [A/G] NM_022569 NDST4 Silent rs11939954 4 115844634 [T/C] NM_022569 NDST4 Silent rs1036757 4 115851183 [T/G] NM_022569 NDST4 Silent rs17679264 4 115856995 [T/C] NM_022569 NDST4 Silent rs1020219 4 115858331 [A/C] NM_022569 NDST4 Silent rs10516608 4 115865849 [T/C] NM_022569 NDST4 Silent rs1441639 4 115867213 [T/C] NM_022569 NDST4 Silent rs2018486 4 115876042 [A/G] NM_022569 NDST4 Silent rs6820993 4 115897055 [T/G] NM_022569 NDST4 Silent rs279512 4 115905854 [A/G] NM_022569 NDST4 Silent rs2028481 4 115910256 [A/G] NM_022569 NDST4 Silent rs279505 4 115912013 [T/C] NM_022569 NDST4 Silent rs4082347 4 115919123 [A/G] NM_022569 NDST4 Silent rs2583515 4 115920956 [A/G] NM_022569 NDST4 Silent rs6856543 4 115939416 [A/C] NM_022569 NDST4 Silent rs979513 4 115952955 [T/C] NM_022569 NDST4 Silent rs1552025 4 115955380 [A/G] NM_022569 NDST4 Silent rs2046050 4 115964380 [A/G] NM_022569 NDST4 Silent rs1383001 4 115973568 [A/G] NM_022569 NDST4 Silent rs499218 4 115974708 [A/G] NM_022569 NDST4 Silent rs517231 4 115995542 [A/G] NM_022569 NDST4 Silent rs541329 4 115995713 [T/C] NM_022569 NDST4 Silent rs509127 4 115996988 [T/C] NM_022569 NDST4 Silent rs13104877 4 116007803 [A/G] NM_022569 NDST4 Silent rs512349 4 116012782 [A/G] NM_022569 NDST4 Silent rs511497 4 116012863 [A/G] NM_022569 NDST4 Silent rs10471004 4 116013330 [T/C] NM_022569 NDST4 Silent rs566198 4 116013647 [T/G] NM_022569 NDST4 Silent rs505277 4 116028808 [T/C] NM_022569 NDST4 Silent rs13105185 4 116032339 [A/C] NM_022569 NDST4 Silent rs580538 4 116054769 [A/G] rs7681396 4 116074054 [A/G] rs1940336 4 116074962 [A/G] rs10018147 4 116077415 [T/C] rs2155516 4 116081714 [T/G] rs1940319 4 116083584 [A/G] rs10516609 4 116084489 [A/G] rs10027823 4 116089855 [T/C] rs7678790 4 116091803 [T/C] rs948186 4 116093537 [T/G] rs4834457 4 116099668 [A/G] rs17685799 4 116105196 [A/G] rs11723597 4 116109043 [A/G] rs6856972 4 116122612 [A/C] rs11940517 4 116126250 [T/G] rs1960049 4 116130120 [A/G] rs11946458 4 116143319 [A/C] rs10029472 4 116151157 [T/G] rs2048163 4 116164027 [T/C] rs963250 4 116168158 [A/G] rs11731910 4 116169689 [A/C] rs2135966 4 116172333 [T/G] rs13150807 4 116173928 [T/C] rs13113622 4 116181809 [A/G] rs7694946 4 116194139 [T/C] rs13128882 4 116211711 [A/G] rs6853566 4 116218720 [T/C] rs1989243 4 116230563 [T/G] rs2389072 4 116232348 [A/G] rs17686110 4 116237539 [A/C] rs11727958 4 116243567 [T/C] rs11725144 4 116246035 [T/C] rs13144926 4 116261419 [T/C] rs6829587 4 116266582 [T/C] rs7434749 4 116276218 [A/G] rs12651062 4 116279442 [A/G] rs10000358 4 116283010 [A/G] rs7437820 4 116291436 [A/G] rs4834476 4 116316085 [T/C] rs6836582 4 116332722 [A/G] rs6533873 4 116336119 [T/C] rs6854632 4 116340193 [A/G] rs6650926 4 116344462 [A/G] rs6830739 4 116349081 [A/G] rs4833482 4 116352641 [A/G] rs12508013 4 116375611 [A/G] rs13131555 4 116377844 [A/G] rs4834488 4 116387928 [T/C] rs12509776 4 116389374 [T/C] rs9997610 4 116391247 [T/G] rs10026917 4 116395664 [T/C] rs6533913 4 116399649 [A/G] rs10026257 4 116405568 [A/G] rs7668500 4 116406659 [A/G] rs9884192 4 116409580 [T/C] rs13129771 4 116411907 [A/G] rs10012098 4 116420387 [A/G] rs6533922 4 116421669 [A/G] rs7435768 4 116426581 [T/C] rs7438394 4 116432420 [T/C] rs4522939 4 116464839 [T/C] rs13105584 4 116509605 [A/G] rs7664444 4 116527361 [T/G] rs17048021 4 116529926 [T/C] rs11098314 4 116529968 [T/C] rs1545763 4 116530435 [A/G] rs1871306 4 116541424 [T/C] rs4566724 4 116541787 [A/G] rs4146409 4 116547100 [T/C] rs1478926 4 116548435 [T/C] rs10002695 4 116560690 [A/C] rs7677317 4 116598539 [T/C] rs6844072 4 116606013 [T/C] rs11942806 4 116612109 [A/G] rs11731956 4 116632011 [T/C] rs13112862 4 116658760 [T/C] rs10017879 4 116658800 [A/G] rs10029219 4 116667561 [A/C] rs7677410 4 116684526 [T/C] rs2389089 4 116710985 [A/G] rs10516621 4 116718238 [A/G] rs17624737 4 116723838 [A/C] rs1013411 4 116727973 [A/C] rs7680117 4 116730435 [T/C] rs13106872 4 116740301 [A/G] rs1549805 4 116766626 [T/G] rs10027974 4 116767251 [A/G] rs13151706 4 116769746 [A/G] rs9999955 4 116786795 [T/C] rs1430934 4 116804645 [T/C] rs1821011 4 116834084 [T/C] rs11098326 4 116844501 [T/G] rs11941706 4 116847736 [T/C] rs1025397 4 116848573 [T/C] rs9307416 4 116862170 [A/G] rs6824665 4 116880079 [A/G] rs1456365 4 116889740 [T/C] rs17586724 4 116893245 [T/C] rs13151079 4 116894599 [A/C] rs17502284 4 116895632 [A/G] rs7669751 4 116908711 [A/G] rs11098331 4 116916813 [A/G] rs10776499 4 116917134 [T/C] rs2045320 4 116920093 [A/G] rs10033887 4 116927517 [T/G] rs10011809 4 116927825 [A/C] rs13135582 4 116932834 [T/C] rs6854280 4 116942805 [A/G] rs6851349 4 116954591 [A/G] rs12509225 4 116973405 [T/C] rs814382 4 116986729 [T/C] rs814383 4 116987639 [T/C] rs10016942 4 116992708 [T/C] rs814397 4 116999572 [T/C] rs701779 4 117017017 [A/G] rs701793 4 117042009 [T/C] rs292911 4 117047226 [T/C] rs13108295 4 117055445 [T/C] rs6858305 4 117073520 [T/C] rs1506732 4 117078327 [A/G] rs1588040 4 117084740 [T/C] rs17048339 4 117099219 [A/G] rs6533958 4 117099769 [A/G] rs1525760 4 117135380 [T/C] rs1021960 4 117141560 [A/G] rs10032309 4 117143010 [T/G] rs1588041 4 117147006 [T/C] rs1032940 4 117148675 [A/C] rs10013632 4 117153619 [A/G] rs1965299 4 117159811 [T/C] rs1387218 4 117163200 [T/G] rs727235 4 117172342 [A/G] rs11938979 4 117211030 [T/C] rs7654510 4 117219559 [A/G] rs6821696 4 117226309 [A/G] rs10428494 4 117227330 [T/C] rs10017789 4 117230366 [A/G] rs11725289 4 117237644 [A/C] rs1489001 4 117245430 [T/C] rs6846808 4 117256020 [T/C] rs1906699 4 117257732 [T/G] rs1873103 4 117262160 [A/G] rs1489012 4 117272840 [T/C] rs6533970 4 117298571 [T/G] rs7675851 4 117300599 [A/G] rs10026309 4 117326046 [T/C] rs6533974 4 117374128 [A/G] rs970943 4 117379825 [A/G] rs6843054 4 117384676 [A/G] rs6826566 4 117387380 [A/G] rs6533976 4 117401394 [T/C] rs6849811 4 117406228 [A/C] rs7697881 4 117407113 [A/G] rs7663989 4 117412778 [T/C] rs11942266 4 117414663 [A/G] rs7700103 4 117424897 [A/G] rs10222978 4 117426252 [T/C] rs13102076 4 117429799 [A/G] rs13127996 4 117438399 [A/G] rs2042651 4 117449878 [A/G] rs7661211 4 117463727 [A/G] rs10024264 4 117468423 [A/G] rs7689892 4 117478490 [A/G] rs12639860 4 117484810 [T/C] rs1582716 4 117509065 [T/C] rs1895794 4 117512637 [A/G] rs1425632 4 117513027 [T/C] rs17632683 4 117516679 [A/C] rs17048699 4 117519753 [A/G] rs4833516 4 117520731 [T/C] rs4557348 4 117525693 [A/G] rs4398591 4 117527892 [A/C] rs13114676 4 117540588 [T/G] rs4560484 4 117543972 [A/C] rs10005909 4 117552737 [T/G] rs6829000 4 117553092 [A/G] rs13134095 4 117557586 [A/G] rs10452193 4 117557970 [T/C] rs10007743 4 117558365 [A/G] rs4240302 4 117562565 [T/G] rs13124273 4 117568631 [T/C] rs4415029 4 117569267 [T/C] rs4640736 4 117569522 [T/C] rs13118630 4 117585086 [A/G] rs7656949 4 117586469 [T/C] rs10012562 4 117594889 [A/C] rs12507901 4 117597044 [A/G] rs6828331 4 117603992 [T/C] rs12648967 4 117609491 [T/C] rs11932733 4 117610982 [T/C] rs4130340 4 117612897 [A/G] rs13106251 4 117613353 [A/G] rs11939225 4 117618126 [A/G] rs4077692 4 117623903 [A/G] rs4274920 4 117624139 [T/C] rs7654840 4 117626118 [A/G] rs7659215 4 117630240 [T/G] rs7682047 4 117630678 [T/C] rs13107698 4 117636735 [T/C] rs11942536 4 117638802 [A/G] rs1500818 4 117653901 [A/G] rs10021925 4 117659634 [T/C] rs6814762 4 117665686 [T/C] rs9996684 4 117675884 [T/C] rs1604230 4 117683039 [T/C] rs12505108 4 117684483 [A/G] rs11726029 4 117687055 [T/C] rs7675219 4 117689811 [A/C] rs12649281 4 117715353 [T/G] rs13114307 4 117716133 [T/G] rs10009620 4 117724087 [T/C] rs17048820 4 117733111 [A/G] rs4834589 4 117743263 [A/G] rs17048841 4 117744350 [T/C] rs1392764 4 117761449 [A/G] rs6856485 4 117763136 [A/G] rs10033111 4 117772331 [A/G] rs6534004 4 117773396 [T/C] rs10005718 4 117779421 [T/C] rs10008401 4 117779937 [T/C] rs1875303 4 117780360 [T/G] rs7668517 4 117783592 [A/G] rs9684450 4 117785317 [T/G] rs12505094 4 117795282 [T/C] rs10033291 4 117795603 [A/C] rs12498620 4 117796697 [A/G] rs2047636 4 117796865 [T/C] rs12498144 4 117799215 [T/G] rs2389247 4 117799718 [T/C] rs17505738 4 117802073 [A/G] rs11098361 4 117803013 [A/G] rs11098362 4 117803266 [T/C] rs10516632 4 117830724 [T/G] rs17590351 4 117832512 [T/C] rs11940805 4 117832770 [A/G] rs1440312 4 117836020 [T/C] rs17505791 4 117844745 [T/C] rs6534006 4 117848472 [A/G] rs979961 4 117850456 [T/C] rs4834594 4 117851859 [T/C] rs1822050 4 117856960 [A/C] rs11941869 4 117863273 [A/G] rs4834599 4 117863537 [T/C] rs12508441 4 117863553 [T/C] rs10050215 4 117867406 [T/C] rs1822046 4 117868349 [A/C] rs717904 4 117868882 [A/G] rs12506385 4 117879013 [A/G] rs12331356 4 117885030 [T/G] rs1440304 4 117888361 [T/C] rs13109536 4 117897658 [A/G] rs10016819 4 117897700 [A/G] rs7697486 4 117912395 [T/C] rs17690630 4 117927811 [T/C] rs10006459 4 117928931 [A/C] rs11734096 4 117931447 [T/C] rs10031489 4 117935564 [A/G] rs12649613 4 117946646 [A/G] rs11098370 4 117950600 [T/C] rs1899071 4 117953708 [A/G] rs17048984 4 117954643 [T/C] rs298924 4 117961014 [A/C] rs298926 4 117962388 [T/C] rs13150008 4 117963914 [T/C] rs298928 4 117964138 [T/C] rs11098373 4 117976279 [T/C] rs298941 4 117981294 [A/G] rs298942 4 117987578 [A/G] rs2196715 4 117993779 [A/G] rs298944 4 118000844 [A/G] rs17049001 4 118003302 [A/G] rs17049006 4 118006307 [A/G] NM_152402 TRAM1L1 EXON Synonymous_A81A rs7683967 4 118007156 [A/C] rs2043805 4 118014813 [T/C] rs3943702 4 118020477 [T/C] rs1438217 4 118039852 [T/C] rs4395584 4 118043043 [T/C] rs7676913 4 118043203 [A/C] rs11933950 4 118043617 [T/C] rs2389370 4 118065922 [T/C] rs2196712 4 118072289 [A/G] rs12504828 4 118078654 [A/G] rs9990523 4 118079219 [A/C] rs10516635 4 118079907 [A/G] rs13110184 4 118080628 [A/G] rs12644587 4 118081229 [T/C] rs11098380 4 118093624 [T/C] rs1438220 4 118109122 [A/G] rs10033670 4 118115286 [T/C] rs10022128 4 118122688 [A/G] rs10025815 4 118131899 [T/C] rs4498198 4 118135356 [T/C] rs4535398 4 118145893 [A/G] rs12639976 4 118155066 [A/G] rs9999009 4 118157777 [A/G] rs7690351 4 118163167 [A/G] rs13147087 4 118164717 [T/C] rs34278822 4 118165691 [A/C] rs6534029 4 118185220 [T/C] rs12644393 4 118190581 [A/G] rs7681687 4 118204404 [T/G] rs11930731 4 118208216 [A/G] rs10033190 4 118215853 [T/C] rs6853512 4 118218045 [T/C] rs4288072 4 118218487 [T/C] rs7678641 4 118219581 [T/G] rs4361453 4 118221551 [T/C] rs13137355 4 118235444 [A/G] rs4833543 4 118239302 [A/G] NR_147151 LINC02262 Silent rs9998109 4 118244984 [A/G] NR_147151 LINC02262 Silent rs17869768 4 118246779 [T/G] NR_147151 LINC02262 Silent rs4074599 4 118246863 [A/G] NR_147151 LINC02262 Silent rs17865908 4 118251420 [A/G] NR_147151 LINC02262 Silent rs4455494 4 118254355 [T/C] NR_147151 LINC02262 Silent rs17861758 4 118254457 [A/G] NR_147151 LINC02262 Silent rs12507136 4 118254740 [T/C] NR_147151 LINC02262 Silent rs7441935 4 118257841 [T/C] NR_147151 LINC02262 Silent rs4416544 4 118262620 [A/G] NR_147151 LINC02262 Silent rs17861768 4 118265683 [A/G] NR_147151 LINC02262 Silent rs4409028 4 118276666 [A/C] NR_147151 LINC02262 Silent rs17869354 4 118279439 [A/G] NR_147151 LINC02262 Silent rs13138792 4 118281116 [T/C] NR_147151 LINC02262 Silent rs11723116 4 118281370 [A/G] NR_147151 LINC02262 Silent rs3925016 4 118292314 [T/C] NR_147152,NR_147153 LINC02263,LINC02263 Silent,Silent rs10034473 4 118297556 [A/G] rs4309912 4 118297655 [A/G] rs7695817 4 118306228 [T/G] rs17865914 4 118307967 [T/C] rs13113229 4 118309390 [A/G] rs17861840 4 118310450 [T/G] rs4834614 4 118313760 [T/C] rs4339281 4 118315560 [A/G] rs17861858 4 118319741 [A/G] rs6839566 4 118320277 [A/G] rs17861866 4 118325168 [T/C] rs7692931 4 118326937 [A/G] rs6851671 4 118327461 [A/G] rs17869264 4 118333003 [T/G] rs17866002 4 118333598 [T/G] rs9996090 4 118334288 [A/G] rs7664551 4 118335241 [T/C] rs4619965 4 118339156 [A/G] rs4385147 4 118340170 [A/C] rs17861884 4 118340693 [T/C] rs17861885 4 118340708 [T/G] rs17875070 4 118340731 [A/G] rs6534034 4 118340767 [T/C] rs17866961 4 118340829 [T/G] rs7658609 4 118341781 [T/C] rs6834348 4 118344201 [A/G] rs6825806 4 118348459 [A/C] rs4240307 4 118351381 [A/C] NR_125757 LINC01378 Silent rs6812138 4 118353315 [A/G] NR_125757 LINC01378 Silent rs17869390 4 118354237 [T/C] NR_125757 LINC01378 Silent rs4632732 4 118358899 [T/C] NR_125757 LINC01378 Silent rs12644762 4 118361718 [T/G] NR_125757 LINC01378 Silent rs17861918 4 118362073 [T/C] NR_125757 LINC01378 Silent rs17865384 4 118362301 [T/C] NR_125757 LINC01378 Silent rs13119978 4 118370511 [T/C] NR_125757 LINC01378 Silent rs11943269 4 118371140 [A/G] NR_125757 LINC01378 Silent rs11932518 4 118373435 [T/C] NR_125757 LINC01378 Silent rs4282258 4 118376267 [A/G] NR_125757 LINC01378 Silent rs17861942 4 118376553 [T/G] NR_125757 LINC01378 Silent rs7675550 4 118379516 [A/G] NR_125757 LINC01378 Silent rs7679074 4 118384890 [T/C] NR_125757 LINC01378 Silent rs6823688 4 118390464 [T/G] NR_125757 LINC01378 Silent rs17861959 4 118393611 [A/G] NR_125757 LINC01378 Silent rs12108495 4 118393990 [A/G] NR_125757 LINC01378 Silent rs4645284 4 118394656 [T/C] NR_125757 LINC01378 Silent rs6827477 4 118395930 [A/G] NR_125757 LINC01378 Silent rs17861965 4 118396765 [A/G] NR_125757 LINC01378 Silent rs12651122 4 118396886 [A/C] NR_125757 LINC01378 Silent rs12510650 4 118402189 [T/G] NR_125757 LINC01378 Silent rs11725039 4 118404415 [T/C] NR_125757 LINC01378 Silent rs6839724 4 118408245 [A/C] NR_125757 LINC01378 Silent rs10014124 4 118408638 [A/G] NR_125757 LINC01378 Silent rs11730021 4 118408687 [A/G] NR_125757 LINC01378 Silent rs6852609 4 118413749 [T/G] NR_125757 LINC01378 Silent rs6842580 4 118417254 [T/C] NR_125757 LINC01378 Silent rs7679549 4 118420131 [A/G] NR_125757 LINC01378 Silent rs17865839 4 118420302 [T/C] NR_125757 LINC01378 Silent rs10006777 4 118435901 [T/C] NR_125757 LINC01378 Silent rs11562936 4 118444804 [A/G] NR_125757 LINC01378 Silent rs6829877 4 118445839 [T/C] NR_125757 LINC01378 Silent rs11562833 4 118446889 [T/G] NR_125757 LINC01378 Silent rs10034912 4 118450681 [T/C] NR_125757 LINC01378 Silent rs17866755 4 118450767 [A/G] NR_125757 LINC01378 Silent rs17867063 4 118451293 [A/G] NR_125757 LINC01378 Silent rs11933680 4 118453775 [A/G] NR_125757 LINC01378 Silent rs1948245 4 118454987 [T/C] NR_125757 LINC01378 Silent rs1017964 4 118463264 [A/G] NR_125757 LINC01378 Silent rs2635252 4 118472730 [T/G] NR_125757 LINC01378 Silent rs1948220 4 118473924 [T/C] NR_125757 LINC01378 Silent rs17869552 4 118474999 [A/C] NR_125757 LINC01378 Silent rs2635348 4 118479461 [T/C] NR_125757 LINC01378 Silent rs11562861 4 118480441 [T/G] NR_125757 LINC01378 Silent rs17863856 4 118481560 [T/C] NR_125757 LINC01378 Silent rs11562934 4 118483198 [A/C] NR_125757 LINC01378 Silent rs1948226 4 118486543 [A/G] NR_125757 LINC01378 Silent rs6813241 4 118488900 [A/G] NR_125757 LINC01378 Silent rs3811755 4 118496919 [T/C] NR_125757 LINC01378 Silent rs2389380 4 118497403 [A/G] NR_125757 LINC01378 Silent rs17865200 4 118497425 [T/C] NR_125757 LINC01378 Silent rs2245104 4 118497883 [T/C] NR_125757 LINC01378 Silent rs11562932 4 118499387 [A/C] NR_125757 LINC01378 Silent rs1906858 4 118504819 [A/G] NR_125757 LINC01378 Silent rs11562911 4 118505004 [T/C] NR_125757 LINC01378 Silent rs13129382 4 118505637 [T/C] NR_125757 LINC01378 Silent rs1352573 4 118505700 [T/C] NR_125757 LINC01378 Silent rs17866122 4 118508890 [A/C] NR_125757 LINC01378 Silent rs11098396 4 118509982 [A/G] NR_125757 LINC01378 Silent rs6850876 4 118510812 [A/G] NR_125757 LINC01378 Silent rs6814620 4 118511981 [T/C] NR_125757 LINC01378 Silent rs17863870 4 118512999 [T/G] NR_125757 LINC01378 Silent rs13135130 4 118513265 [A/G] NR_125757 LINC01378 Silent rs17862044 4 118514488 [T/C] NR_125757 LINC01378 Silent rs2130238 4 118516983 [T/C] NR_125757 LINC01378 Silent rs2635191 4 118519146 [A/G] NR_125757 LINC01378 Silent rs10019567 4 118519506 [T/C] NR_125757 LINC01378 Silent rs17866855 4 118520000 [T/C] NR_125757 LINC01378 Silent rs17869268 4 118528622 [T/C] NR_125757 LINC01378 Silent rs12511367 4 118531857 [T/C] NR_125757 LINC01378 Silent rs2635295 4 118532328 [T/C] NR_125757 LINC01378 Silent rs17867517 4 118536785 [T/C] NR_125757 LINC01378 Silent rs17862054 4 118538842 [A/G] NR_125757 LINC01378 Silent rs9999101 4 118541595 [T/C] NR_125757 LINC01378 Silent rs2220497 4 118542986 [T/C] NR_125757 LINC01378 Silent rs11562909 4 118543044 [T/C] NR_125757 LINC01378 Silent rs2635299 4 118543358 [T/C] NR_125757 LINC01378 Silent rs923441 4 118544344 [T/C] NR_125757 LINC01378 Silent rs1948223 4 118545387 [T/C] NR_125757 LINC01378 Silent rs1304736 4 118547300 [T/C] NR_125757 LINC01378 Silent rs1948221 4 118548943 [T/G] NR_125757 LINC01378 Silent rs1948250 4 118551128 [T/C] NR_125757 LINC01378 Silent rs2635302 4 118553272 [A/G] NR_125757 LINC01378 Silent rs2247756 4 118556306 [A/C] NR_125757 LINC01378 Silent rs17865601 4 118558034 [A/G] NR_125757 LINC01378 Silent rs7699563 4 118558928 [A/C] NR_125757 LINC01378 Silent rs6818184 4 118560727 [T/C] NR_125757 LINC01378 Silent rs2635304 4 118560782 [T/C] NR_125757 LINC01378 Silent rs2635199 4 118567841 [T/G] NR_125757 LINC01378 Silent rs2389381 4 118587270 [A/C] NR_125757 LINC01378 Silent rs1459545 4 118599194 [A/C] NR_125757 LINC01378 Silent rs4834632 4 118608250 [A/G] NR_125757 LINC01378 Silent rs1459551 4 118610383 [A/C] rs17862984 4 118612335 [A/C] rs4551001 4 118613005 [A/G] rs10011738 4 118617008 [T/C] rs17862070 4 118622573 [T/C] rs1120641 4 118627589 [T/C] rs10022014 4 118629807 [A/G] rs7681998 4 118635598 [T/G] rs17874759 4 118636209 [A/G] rs6834486 4 118638662 [A/C] rs10009424 4 118641047 [T/G] rs17862991 4 118644106 [T/C] rs11098403 4 118646907 [A/G] rs11562926 4 118650042 [T/C] rs11562852 4 118653376 [T/G] rs17867545 4 118653690 [T/C] rs7678262 4 118663416 [A/G] rs11945758 4 118667234 [T/G] rs11562835 4 118667520 [A/G] rs17864992 4 118684443 [T/C] rs1350618 4 118689954 [A/G] rs4585377 4 118705004 [T/C] rs17869797 4 118705939 [A/G] rs2125709 4 118707424 [A/G] rs17867039 4 118716196 [A/G] rs7698673 4 118717350 [A/C] rs10011297 4 118717631 [T/G] rs4377657 4 118722033 [T/C] rs17865896 4 118722199 [T/C] rs17869743 4 118722751 [A/G] rs17866059 4 118724333 [A/G] rs11562865 4 118727351 [A/G] rs994619 4 118731430 [T/C] rs11562869 4 118738469 [A/G] rs11562921 4 118740650 [A/G] rs6811518 4 118756418 [T/C] NR_147154 LINC02264 Silent rs4597906 4 118758795 [T/C] NR_147154 LINC02264 Silent rs6813598 4 118760390 [T/G] NR_147154 LINC02264 Silent rs12503813 4 118784946 [T/C] NR_147154 LINC02264 Silent rs7696793 4 118789715 [T/C] NR_147154 LINC02264 Silent rs7675389 4 118789858 [T/C] NR_147154 LINC02264 Silent rs4131119 4 118802784 [A/G] rs6534063 4 118803489 [A/G] rs4543205 4 118820791 [A/C] rs6834344 4 118851421 [A/G] rs11946339 4 118868678 [T/C] rs6534066 4 118870933 [A/G] rs11098416 4 118891359 [A/G] rs2892782 4 118895571 [T/C] rs6813909 4 118899646 [T/C] rs4833558 4 118919497 [T/C] rs10516642 4 118929651 [T/C] rs9997637 4 118932958 [T/G] rs4516795 4 118933272 [A/G] rs11098419 4 118939953 [T/G] rs2389487 4 118940052 [A/G] rs2389489 4 118941387 [T/C] rs6849073 4 118941742 [A/G] rs10000049 4 118948220 [A/C] rs3134 4 118950151 [A/G] rs6534078 4 118953901 [A/G] rs10857057 4 118963085 [A/G] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs2389508 4 118985104 [T/C] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs2389513 4 119001513 [T/C] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs10015485 4 119014481 [T/C] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs4428355 4 119020848 [A/G] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs4240315 4 119024014 [T/C] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs4833561 4 119047274 [A/G] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs10028980 4 119059289 [T/C] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 EXON Silent,Synonymous_Y435Y,Silent rs13114867 4 119068637 [T/G] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs6853879 4 119072862 [A/G] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs6842491 4 119075936 [A/G] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs11947911 4 119091089 [T/C] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs12505156 4 119115366 [A/G] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs2892800 4 119134308 [T/C] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs10028343 4 119138539 [A/G] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs2204269 4 119142770 [T/G] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs788663 4 119155229 [T/C] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs617430 4 119161795 [A/G] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 EXON Silent,Synonymous_P745P,Silent rs687492 4 119170256 [T/C] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs631271 4 119175904 [A/G] NR_146513,NM_004784,NR_146514 NDST3,NDST3,NDST3 Silent,Silent,Silent rs11935016 4 119185216 [T/C] rs10006799 4 119193859 [A/G] rs13135360 4 119198004 [T/C] rs1573955 4 119199879 [T/G] rs10212745 4 119202179 [T/C] NM_003619 PRSS12 EXON Silent rs17594503 4 119203221 [T/C] NM_003619 PRSS12 EXON Missense_R833Q rs11098432 4 119203708 [A/C] NM_003619 PRSS12 Silent rs4833571 4 119204720 [A/C] NM_003619 PRSS12 Silent rs11730327 4 119228883 [T/C] NM_003619 PRSS12 Silent rs17693234 4 119229752 [T/C] NM_003619 PRSS12 Silent rs4834678 4 119240618 [T/C] NM_003619 PRSS12 Silent rs1523743 4 119266964 [T/C] NM_003619 PRSS12 Silent rs7674055 4 119272958 [T/C] NM_003619 PRSS12 Silent rs10016452 4 119277490 [A/G] rs1514657 4 119279098 [T/C] rs16997447 4 119293100 [A/G] rs1913576 4 119297789 [T/C] rs2892812 4 119299078 [T/C] rs11932636 4 119302960 [A/G] rs7696047 4 119303024 [A/G] rs12498329 4 119311524 [T/C] rs7670395 4 119317964 [T/C] rs1818521 4 119322004 [T/C] rs12504468 4 119322322 [A/G] rs10518293 4 119331363 [A/G] rs6811485 4 119337263 [A/G] rs2728344 4 119351824 [A/C] rs2631108 4 119371173 [A/G] rs4834691 4 119398282 [T/C] rs17693682 4 119399111 [T/C] rs10021843 4 119407189 [T/C] rs17642621 4 119408351 [A/G] rs2035600 4 119437972 [A/G] NR_003135 CEP170P1 Silent rs4001461 4 119441680 [T/C] NR_003135 CEP170P1 Silent rs28664750 4 119449556 [T/C] NR_003135 CEP170P1 Silent rs17595265 4 119455055 [A/G] NR_003135 CEP170P1 Silent rs2200517 4 119462685 [T/C] NR_003135 CEP170P1 Silent rs11728902 4 119483415 [A/G] rs10008020 4 119503609 [T/C] rs7689541 4 119506139 [A/G] rs7669896 4 119510402 [A/G] rs9761692 4 119567203 [A/G] rs299005 4 119595364 [A/G] NR_125930 LOC101929741 Silent rs298982 4 119605009 [A/G] NR_125930 LOC101929741 Silent rs298980 4 119607376 [T/C] NM_020961 METTL14 Silent rs10002843 4 119608976 [A/G] NM_020961 METTL14 Silent rs9968326 4 119609039 [A/G] NM_020961 METTL14 Silent rs6821350 4 119613045 [T/G] NM_020961 METTL14 Silent rs6813357 4 119624641 [T/G] NM_020961 METTL14 Silent rs441216 4 119630402 [A/G] NM_020961 METTL14 Silent rs12640223 4 119643010 [A/G] rs298991 4 119646000 [A/G] NM_014822,NM_001318066 SEC24D,SEC24D Silent,Silent rs298988 4 119648399 [A/G] NM_014822,NM_001318066 SEC24D,SEC24D Silent,Silent rs960738 4 119651565 [T/C] NM_014822,NM_001318066 SEC24D,SEC24D Silent,Silent rs10033943 4 119654624 [A/G] NM_014822,NM_001318066 SEC24D,SEC24D Silent,Silent rs12509236 4 119655888 [T/C] NM_014822,NM_001318066 SEC24D,SEC24D Silent,Silent rs4834700 4 119664228 [T/C] NM_014822,NM_001318066 SEC24D,SEC24D Silent,Silent rs11098448 4 119665051 [A/C] NM_014822,NM_001318066 SEC24D,SEC24D Silent,Silent rs6827740 4 119675900 [T/C] NM_014822,NM_001318066 SEC24D,SEC24D Silent,Silent rs4340779 4 119678580 [T/G] NM_014822,NM_001318066 SEC24D,SEC24D Silent,Silent rs4834703 4 119691624 [A/G] NM_014822,NM_001318066 SEC24D,SEC24D Silent,Silent rs10518325 4 119717634 [A/G] NM_014822,NM_001318066 SEC24D,SEC24D Silent,Silent rs4834706 4 119733366 [T/C] NM_014822,NM_001318066 SEC24D,SEC24D Silent,Silent rs4461510 4 119736796 [A/C] NM_014822,NM_001318066 SEC24D,SEC24D EXON Synonymous_P161P,Synonymous_P161P rs6843239 4 119743682 [T/C] NM_014822,NM_001318066 SEC24D,SEC24D Silent,Silent rs13139244 4 119752920 [A/G] NM_014822,NM_001318066 SEC24D,SEC24D Silent,Silent rs11730732 4 119761678 [A/G] rs2162400 4 119762951 [T/G] rs7676892 4 119768598 [T/C] rs10019751 4 119770915 [T/C] rs17324968 4 119772316 [T/C] NM_001286754 SYNPO2 Silent rs10857061 4 119781338 [T/C] NM_001286754 SYNPO2 Silent rs2114461 4 119785381 [T/G] NM_001286754 SYNPO2 Silent rs7679385 4 119790013 [A/G] NM_001286754 SYNPO2 Silent rs4240322 4 119792297 [A/C] NM_001286754 SYNPO2 Silent rs4834711 4 119793776 [T/C] NM_001286754 SYNPO2 Silent rs1426819 4 119795642 [A/G] NM_001286754 SYNPO2 Silent rs6534110 4 119800081 [T/C] NM_001286754 SYNPO2 Silent rs7690236 4 119800779 [T/C] NM_001286754 SYNPO2 Silent rs7695141 4 119801012 [T/C] NM_001286754 SYNPO2 Silent rs11940444 4 119807193 [A/G] NM_001286754 SYNPO2 Silent rs28465250 4 119809572 [A/G] NM_001286754 SYNPO2 Silent rs13117019 4 119811735 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs10518319 4 119812197 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs6831957 4 119817622 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs4834713 4 119825219 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs955607 4 119827183 [A/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs12506322 4 119831193 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs736965 4 119833292 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs7676506 4 119835148 [T/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs2162398 4 119844851 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs754397 4 119846806 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs13138512 4 119853638 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs7672077 4 119859344 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs1565475 4 119860592 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs6826016 4 119862144 [T/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs17261234 4 119864315 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs17327171 4 119864599 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs4834729 4 119865067 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs1021377 4 119867342 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs17261423 4 119867681 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs13130144 4 119873248 [T/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs10025067 4 119874955 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs1387981 4 119875492 [A/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs12508843 4 119877794 [T/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs6858546 4 119881072 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs10518316 4 119883564 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs7697974 4 119884361 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs1490510 4 119886179 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs17050209 4 119890139 [A/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs1038771 4 119890772 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs17050208 4 119890865 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs6855192 4 119892879 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs11098467 4 119896186 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs9307465 4 119896331 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs17050196 4 119896633 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs1387983 4 119899664 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs4833599 4 119902065 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs1847 4 119903064 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs4834733 4 119907402 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs7437916 4 119912286 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs17328610 4 119913577 [A/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs2061443 4 119914670 [A/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs1380163 4 119922111 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs1994630 4 119927268 [A/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs983417 4 119929733 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs1380158 4 119932620 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs1380159 4 119934384 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs1459056 4 119941399 [T/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs17263826 4 119946706 [T/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs6828669 4 119947135 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs7671665 4 119947188 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs12511929 4 119947362 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs17263971 4 119948046 [A/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 EXON Missense_Q143H,Missense_Q174H,Silent,Missense_Q174H,Missense_Q174H rs17050152 4 119948059 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 EXON Missense_A148T,Missense_A179T,Silent,Missense_A179T,Missense_A179T rs2045547 4 119950186 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent,Silent,Silent rs7698598 4 119951647 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 EXON Missense_T542A,Missense_T573A,Silent,Missense_T573A,Missense_T573A rs13837 4 119954533 [T/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 EXON Silent,Silent,Silent,Silent,Silent rs2279506 4 119954710 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 EXON Silent,Silent,Silent,Silent,Silent rs3733511 4 119955787 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 EXON Silent,Silent,Silent,Silent,Silent rs752097 4 119956089 [A/G] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 EXON Silent,Silent,Silent,Silent,Silent rs749410 4 119956411 [T/C] NM_001286754,NM_133477,NM_001286755,NM_001128933,NM_001128934 SYNPO2,SYNPO2,SYNPO2,SYNPO2,SYNPO2 EXON Silent,Silent,Silent,Silent,Silent rs10518313 4 119962741 [A/G] NM_001286754,NM_133477,NM_001286755 SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent rs17264415 4 119963526 [A/G] NM_001286754,NM_133477,NM_001286755 SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent rs9784534 4 119963646 [A/C] NM_001286754,NM_133477,NM_001286755 SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent rs1037763 4 119966718 [A/G] NM_001286754,NM_133477,NM_001286755 SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent rs1380162 4 119970203 [A/G] NM_001286754,NM_133477,NM_001286755 SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent rs13137064 4 119971043 [T/C] NM_001286754,NM_133477,NM_001286755 SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent rs12506805 4 119974540 [T/C] NM_001286754,NM_133477,NM_001286755 SYNPO2,SYNPO2,SYNPO2 Silent,Silent,Silent rs17050126 4 119979001 [T/C] NM_001286754,NM_133477,NM_001286755 SYNPO2,SYNPO2,SYNPO2 EXON Missense_M1202T,Missense_M1233T,Silent rs17050125 4 119980501 [T/G] NM_001286754,NM_133477,NM_001286755 SYNPO2,SYNPO2,SYNPO2 EXON Silent,Silent,Silent rs1058450 4 119980640 [T/C] NM_001286754,NM_133477,NM_001286755 SYNPO2,SYNPO2,SYNPO2 EXON Silent,Silent,Silent rs17050116 4 119981296 [A/G] NM_001286754,NM_133477,NM_001286755 SYNPO2,SYNPO2,SYNPO2 EXON Silent,Silent,Silent rs1047894 4 119981828 [T/G] NM_001286754,NM_133477,NM_001286755 SYNPO2,SYNPO2,SYNPO2 EXON Silent,Silent,Silent rs10002998 4 119991367 [T/G] rs6837925 4 119994350 [T/C] rs12509365 4 119994554 [A/G] rs11098479 4 120005147 [T/C] rs2219497 4 120005814 [A/G] rs7441142 4 120008227 [T/C] rs7670862 4 120008569 [T/C] rs10857064 4 120009168 [A/G] rs11729054 4 120013157 [T/C] rs17331353 4 120013791 [T/C] rs17050077 4 120014898 [T/C] rs11098483 4 120016617 [T/C] rs11098484 4 120018082 [A/C] rs4261975 4 120025002 [T/C] rs9307467 4 120029332 [A/G] rs10029388 4 120029841 [A/G] rs10017227 4 120041315 [T/G] rs2168987 4 120043874 [T/C] rs11934309 4 120045740 [T/C] rs9307468 4 120048884 [A/G] rs898168 4 120052592 [A/G] rs4833607 4 120053224 [T/G] rs4834752 4 120055799 [T/G] rs1459055 4 120056815 [A/G] rs7694500 4 120063715 [T/C] NM_016599 MYOZ2 Silent rs4834755 4 120067244 [A/G] NM_016599 MYOZ2 Silent rs6844238 4 120067703 [A/G] NM_016599 MYOZ2 Silent rs4452412 4 120072585 [A/G] NM_016599 MYOZ2 Silent rs7669431 4 120077220 [A/G] NM_016599 MYOZ2 Silent rs11098489 4 120081606 [A/G] NM_016599 MYOZ2 Silent rs7687613 4 120085448 [A/G] NM_016599 MYOZ2 EXON Synonymous_E153E rs9995277 4 120108603 [A/G] NM_016599 MYOZ2 EXON Silent rs17049978 4 120112049 [A/G] rs10022508 4 120115228 [A/G] NR_125931 LOC101929762 EXON Silent rs11737086 4 120127117 [T/C] NR_125931 LOC101929762 Silent rs6829732 4 120130528 [T/C] NR_125931 LOC101929762 Silent rs4834762 4 120132690 [T/C] NR_125931 LOC101929762 Silent rs12644283 4 120133549 [T/G] NR_125931 LOC101929762 Silent rs6833072 4 120133892 [T/C] NM_019050 USP53 EXON Silent rs10084915 4 120138824 [A/G] NM_019050 USP53 EXON Silent rs4833611 4 120147460 [T/C] NM_019050 USP53 Silent rs951570 4 120150467 [T/C] NM_019050 USP53 Silent rs10031033 4 120151452 [T/C] NM_019050 USP53 Silent rs6853317 4 120151624 [A/G] NM_019050 USP53 Silent rs13113112 4 120156040 [T/C] NM_019050 USP53 Silent rs11944880 4 120159334 [T/C] NM_019050 USP53 Silent rs7356185 4 120167111 [T/C] NM_019050 USP53 Silent rs13139045 4 120168588 [T/C] NM_019050 USP53 Silent rs7668423 4 120177708 [T/C] NM_019050 USP53 Silent rs6823331 4 120180790 [T/C] NM_019050 USP53 Silent rs11098498 4 120187119 [T/C] NM_019050 USP53 Silent rs11098499 4 120187611 [T/C] NM_019050 USP53 Silent rs3749590 4 120213827 [T/C] NM_019050 USP53 EXON Synonymous_L895L rs3749591 4 120214030 [T/G] NM_019050 USP53 EXON Missense_S962R rs1052633 4 120215314 [A/G] NM_019050 USP53 EXON Silent rs17595398 4 120219517 [A/C] NM_001001701,NM_001170330 C4orf3,C4orf3 EXON Missense_N206K,Missense_N339K rs11731571 4 120221185 [A/G] NM_001001701,NM_001170330 C4orf3,C4orf3 Silent,Silent rs13127517 4 120222883 [T/C] NM_001170330 C4orf3 Silent rs4834769 4 120230446 [A/G] rs1397607 4 120231150 [A/G] rs13118936 4 120234402 [A/G] rs10518301 4 120235125 [T/C] rs878374 4 120237564 [A/G] rs878372 4 120238780 [A/C] NM_000134 FABP2 EXON Silent rs11724758 4 120239878 [A/G] NM_000134 FABP2 EXON Silent rs9999724 4 120239944 [T/C] NM_000134 FABP2 EXON Silent rs1511025 4 120240238 [T/C] NM_000134 FABP2 EXON Synonymous_V119V rs4834770 4 120241849 [A/G] NM_000134 FABP2 EXON Synonymous_N72N rs1799883 4 120241902 [T/C] NM_000134 FABP2 EXON Missense_T55A rs1397614 4 120243352 [T/C] rs10034661 4 120244085 [A/G] rs9995716 4 120264996 [T/C] rs9637625 4 120276345 [A/G] rs4834773 4 120277395 [A/G] rs11722431 4 120289042 [T/G] rs4833618 4 120309500 [T/C] rs6846442 4 120326323 [A/G] rs2389794 4 120361819 [A/G] rs7659551 4 120371729 [T/C] NR_135112 GTF2IP12 Silent rs2892848 4 120381341 [T/C] NR_037630 LOC645513 EXON Silent rs7654587 4 120388406 [T/C] NR_037630 LOC645513 Silent rs11098524 4 120390032 [A/G] NR_037630 LOC645513 Silent rs10032158 4 120391632 [T/C] NR_037630 LOC645513 Silent rs17012099 4 120392652 [A/G] NR_037630 LOC645513 Silent rs10034623 4 120397829 [A/G] NR_037630 LOC645513 Silent rs988146 4 120399505 [A/G] NR_037630 LOC645513 Silent rs10518329 4 120401835 [A/G] NR_037630 LOC645513 Silent rs10006525 4 120408931 [T/G] NR_037630 LOC645513 Silent rs17355550 4 120416096 [T/C] NR_037630,NM_033437,NM_033430,NM_001083 LOC645513,PDE5A,PDE5A,PDE5A EXON Silent,Silent,Silent,Silent rs13124532 4 120416445 [T/C] NR_037630,NM_033437,NM_033430,NM_001083 LOC645513,PDE5A,PDE5A,PDE5A EXON Silent,Silent,Silent,Silent rs11734241 4 120416872 [A/G] NR_037630,NM_033437,NM_033430,NM_001083 LOC645513,PDE5A,PDE5A,PDE5A EXON Silent,Silent,Silent,Silent rs3733524 4 120423729 [T/C] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs6843229 4 120424087 [T/C] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs13107334 4 120424580 [T/G] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs4834779 4 120425246 [A/G] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs13121569 4 120428404 [A/G] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs3822192 4 120445720 [A/C] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs1155577 4 120449810 [T/C] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs1155576 4 120450159 [A/C] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs17358524 4 120491714 [A/G] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs12646525 4 120502461 [T/C] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs10012485 4 120508298 [T/C] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs2389870 4 120522038 [T/C] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs10518335 4 120522172 [T/C] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs10518336 4 120522934 [A/G] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs17051276 4 120528064 [A/C] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A EXON Missense_S129A,Missense_S139A,Missense_S181A rs6847164 4 120534734 [T/C] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs6534146 4 120538823 [A/G] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs6832740 4 120546136 [T/C] NM_033437,NM_033430,NM_001083 PDE5A,PDE5A,PDE5A Silent,Silent,Silent rs3806808 4 120551085 [A/C] rs10009566 4 120558608 [T/C] rs6844418 4 120569563 [A/G] rs2389891 4 120576177 [A/G] rs4833624 4 120585497 [T/C] rs9994651 4 120587803 [A/G] rs1986695 4 120589750 [A/C] rs10003106 4 120595698 [A/G] rs2389896 4 120600424 [A/G] rs13122890 4 120601731 [T/G] rs17051382 4 120605557 [A/G] rs2253404 4 120606495 [A/G] rs2715023 4 120609868 [A/G] rs7683474 4 120612853 [T/C] rs17295253 4 120613018 [A/C] rs12510467 4 120618359 [A/G] rs4094 4 120619421 [T/G] rs1009077 4 120627421 [A/G] rs2714961 4 120628627 [T/C] rs4337717 4 120643040 [A/C] rs11726524 4 120643124 [A/C] rs749526 4 120663649 [T/G] rs2714982 4 120665038 [T/G] rs13112498 4 120670520 [A/C] rs4447843 4 120680950 [A/G] rs11736455 4 120685312 [T/C] rs17005814 4 120690702 [T/C] rs2389957 4 120695322 [T/C] rs6534152 4 120704766 [A/G] rs11729954 4 120709561 [T/G] rs17006113 4 120714886 [T/C] rs7699214 4 120716967 [A/G] rs2389954 4 120721063 [T/C] NR_110660 LINC01365 Silent rs2389923 4 120731697 [T/C] rs10004197 4 120736449 [A/G] rs1503538 4 120757419 [T/G] rs7690791 4 120758258 [A/G] rs7688177 4 120760872 [T/C] rs1124166 4 120773133 [T/C] rs17006835 4 120775160 [A/G] rs1123767 4 120775448 [T/G] rs10452195 4 120776279 [T/G] rs722766 4 120776752 [T/C] rs17364898 4 120784320 [A/G] rs17006982 4 120788956 [A/G] rs17007018 4 120790617 [T/C] rs1818167 4 120790884 [T/C] rs4834821 4 120797098 [T/G] rs1587734 4 120809455 [T/C] rs1503540 4 120812306 [T/C] rs17007348 4 120817221 [A/C] rs13132107 4 120821994 [T/C] rs10471014 4 120826312 [T/G] rs6812590 4 120830249 [T/G] rs2202272 4 120838437 [A/G] rs17300152 4 120842452 [A/C] rs11098551 4 120843895 [A/G] rs10018121 4 120846553 [A/C] rs12508689 4 120847421 [A/G] rs12502497 4 120866594 [A/G] NR_121639 LINC02502 Silent rs2389925 4 120880067 [A/G] NR_121639 LINC02502 Silent rs1503535 4 120898509 [A/G] rs13134800 4 120900282 [T/C] rs10025255 4 120903397 [A/G] rs17366987 4 120905242 [T/C] rs7678743 4 120909594 [A/G] rs1604711 4 120910200 [T/C] rs2389926 4 120912054 [T/C] rs11098555 4 120927641 [A/G] rs17008785 4 120930676 [T/G] rs1847333 4 120939273 [T/C] rs1503534 4 120939685 [A/G] rs6856643 4 120942372 [A/G] rs1967119 4 120946927 [A/G] rs7682093 4 120952246 [T/C] rs6823111 4 120952953 [T/G] rs10006314 4 120953490 [T/C] rs12374290 4 120962025 [A/G] rs1845344 4 120962385 [T/G] rs6828161 4 120968070 [A/G] rs7677531 4 120969089 [A/C] rs6827271 4 120971860 [T/G] rs17009453 4 120972650 [T/C] rs13126776 4 120973238 [A/G] rs2908989 4 120983259 [T/C] NM_002358 MAD2L1 Silent rs2908988 4 120984369 [T/C] NM_002358 MAD2L1 Silent rs2934379 4 120986142 [T/C] NM_002358 MAD2L1 Silent rs10446729 4 120988552 [A/G] rs12711084 4 120989853 [T/C] rs13121806 4 120990081 [T/C] rs2892890 4 120992642 [T/C] rs6855113 4 121005634 [A/G] rs972311 4 121017399 [T/C] rs6831851 4 121021737 [T/C] rs1908169 4 121033187 [T/C] rs17010476 4 121034480 [T/C] rs7695341 4 121042212 [A/G] rs9307484 4 121056511 [T/G] rs4834836 4 121056595 [A/C] rs6842087 4 121058095 [T/C] rs13142346 4 121063357 [T/G] rs6854848 4 121063683 [T/C] rs10022765 4 121078848 [A/G] rs10030192 4 121093248 [A/G] rs12644766 4 121095379 [T/C] rs13102180 4 121100036 [A/G] rs13116644 4 121105615 [A/G] rs1509002 4 121107275 [T/C] rs2662756 4 121108446 [T/C] rs1509001 4 121110203 [T/C] rs1876701 4 121114622 [T/C] rs6851191 4 121117729 [A/G] rs13127309 4 121139889 [T/G] rs2662692 4 121140144 [T/G] rs13134323 4 121149877 [T/C] rs2662733 4 121160229 [T/G] rs9684604 4 121164119 [A/G] rs2662738 4 121167953 [T/C] rs2715990 4 121168762 [T/C] rs1355112 4 121183954 [T/C] rs17012481 4 121185834 [T/C] rs7674589 4 121193911 [A/C] rs2715970 4 121206490 [T/C] rs2662744 4 121207648 [A/G] rs17012768 4 121226269 [A/G] rs2662715 4 121229736 [A/C] rs1543277 4 121232742 [T/C] rs2715952 4 121239258 [A/G] rs6850328 4 121242474 [T/G] rs1405241 4 121248446 [T/C] rs2715992 4 121261806 [T/C] rs1160185 4 121263497 [A/G] rs6829985 4 121263925 [T/C] rs950658 4 121269728 [T/C] rs7683870 4 121270939 [A/G] rs10032781 4 121282335 [A/G] rs6817848 4 121292818 [A/G] rs1374988 4 121292945 [T/C] rs1526326 4 121298764 [A/C] rs9992211 4 121319869 [T/C] rs1448065 4 121323123 [A/G] rs2166838 4 121323918 [T/C] rs1073494 4 121328397 [T/G] rs7694494 4 121339394 [T/G] rs1405240 4 121342283 [T/C] rs1808015 4 121342367 [A/C] rs705103 4 121347367 [A/G] rs697364 4 121347730 [T/C] rs1026083 4 121351003 [T/G] rs7667780 4 121351589 [A/G] rs11938648 4 121353265 [A/G] rs1448083 4 121361500 [T/C] rs843613 4 121368939 [A/G] rs1685593 4 121371794 [T/C] rs863620 4 121393821 [T/G] rs843596 4 121395169 [T/C] rs7697117 4 121396721 [T/G] rs12501789 4 121397402 [A/G] rs17339087 4 121402735 [A/C] rs4833161 4 121403974 [A/G] rs1994475 4 121406055 [A/G] rs17050662 4 121417757 [T/C] rs843605 4 121426884 [T/C] rs1099248 4 121427036 [T/C] rs17050741 4 121427700 [A/C] rs6841772 4 121429603 [A/G] rs17339852 4 121429845 [A/G] rs10024986 4 121450846 [T/C] rs2390022 4 121457685 [A/G] rs4833652 4 121474572 [A/G] rs1386814 4 121474967 [A/G] rs12511769 4 121478712 [T/C] rs6855878 4 121479039 [A/G] rs6856719 4 121479398 [A/G] rs4395533 4 121481950 [A/G] rs11098574 4 121487559 [A/G] rs1532055 4 121489983 [A/G] rs6854696 4 121491629 [A/G] rs13112492 4 121513696 [A/G] rs13121429 4 121525149 [A/G] rs10002802 4 121526447 [T/G] rs11732932 4 121532558 [A/G] rs1353473 4 121535293 [A/G] rs10518365 4 121536939 [A/G] rs11098579 4 121538689 [A/G] rs1463782 4 121539450 [A/G] rs17051145 4 121545138 [T/G] rs10518367 4 121545814 [T/C] rs7693486 4 121552714 [T/G] rs17343008 4 121552826 [A/G] rs17051152 4 121553198 [T/C] rs7667818 4 121575053 [T/C] rs6818888 4 121581769 [A/C] rs13138888 4 121582628 [A/C] rs1580743 4 121587269 [T/C] rs1580742 4 121587550 [T/C] rs1496270 4 121588603 [A/G] rs11733936 4 121593373 [A/C] rs10027783 4 121594207 [A/G] rs1874442 4 121623057 [A/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs1496276 4 121623516 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs1390563 4 121626824 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs724818 4 121627113 [A/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs17345994 4 121627842 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs11730092 4 121630332 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs7657769 4 121633580 [A/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs17346468 4 121637499 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs10518375 4 121637960 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs17051233 4 121641726 [A/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs6838858 4 121642180 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs843575 4 121645012 [A/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs11931792 4 121645756 [T/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs10518377 4 121648617 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs17347051 4 121652465 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs2667182 4 121655130 [A/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs10518378 4 121661208 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs7661193 4 121669224 [A/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs11725662 4 121671965 [T/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs10857072 4 121683755 [A/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs6813562 4 121684267 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs13147610 4 121685814 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs907298 4 121691899 [A/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs17051254 4 121703782 [A/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs2390053 4 121705238 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs12499000 4 121706201 [A/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 EXON Synonymous_L381L,Synonymous_L381L,Synonymous_L412L rs13111620 4 121709930 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs6827372 4 121714045 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs3804174 4 121719932 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs34666716 4 121720883 [A/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 EXON Synonymous_D290D,Synonymous_D290D,Synonymous_D321D rs17051264 4 121737624 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 EXON Synonymous_Q252Q,Synonymous_Q252Q,Synonymous_Q283Q rs343192 4 121738049 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 EXON Silent,Silent,Synonymous_L227L rs1511301 4 121746462 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs1033097 4 121750566 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs7673521 4 121755299 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs343175 4 121759300 [A/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs343176 4 121759338 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs12509870 4 121759963 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs6534216 4 121765527 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs1588523 4 121766616 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs3115310 4 121774515 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs10518380 4 121775592 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs9997435 4 121776394 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs1450476 4 121784013 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs2597553 4 121786273 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs7675777 4 121789730 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs17051273 4 121792785 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs6844159 4 121794535 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs343202 4 121795956 [A/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs17051275 4 121801457 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs2667175 4 121803254 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs11723050 4 121814232 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs343168 4 121816501 [A/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs2390060 4 121822600 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs2122512 4 121830057 [A/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs11939905 4 121831385 [A/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs6844456 4 121831539 [A/G] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs1450478 4 121837791 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs1470696 4 121842567 [T/C] NM_001300824,NM_001300823,NM_018699 PRDM5,PRDM5,PRDM5 Silent,Silent,Silent rs6848268 4 121857957 [T/G] rs7673618 4 121859395 [T/G] rs10018902 4 121862501 [A/G] rs1450471 4 121873063 [T/C] rs13132472 4 121875311 [A/G] rs13132115 4 121875396 [A/G] rs11734432 4 121882501 [A/G] rs11098592 4 121888708 [T/C] rs6855125 4 121889053 [T/C] rs12648040 4 121893179 [A/G] rs12641971 4 121893316 [A/G] rs6841260 4 121894207 [T/C] rs6855437 4 121898421 [A/G] rs6824931 4 121904225 [T/C] rs4498152 4 121931785 [T/C] rs1807071 4 121938296 [A/C] rs6534243 4 121939643 [T/C] rs11931955 4 121940998 [T/C] rs12509928 4 121944932 [T/C] rs10461204 4 121956610 [A/G] rs1045080 4 121957051 [T/C] NM_024574 NDNF EXON Silent rs3733558 4 121958091 [T/G] NM_024574 NDNF EXON Synonymous_L345L rs3733560 4 121958697 [A/G] NM_024574 NDNF EXON Synonymous_S143S rs17051284 4 121972302 [T/C] NM_024574 NDNF Silent rs11098600 4 121972352 [A/C] NM_024574 NDNF Silent rs11931196 4 121974645 [T/C] NM_024574 NDNF Silent rs17051286 4 121976444 [T/C] NM_024574 NDNF Silent rs4833705 4 121978877 [T/C] NM_024574 NDNF Silent rs882045 4 121982736 [A/G] NM_024574 NDNF Silent rs6829190 4 121984023 [T/C] NM_024574 NDNF Silent rs2390070 4 121986137 [T/G] NM_024574 NDNF Silent rs2136947 4 121988791 [T/C] NM_024574 NDNF Silent rs6823534 4 121997348 [T/C] rs1105274 4 122010915 [T/G] rs13128284 4 122015591 [A/G] rs13111873 4 122019998 [A/C] rs13142482 4 122024540 [A/G] rs1397643 4 122028784 [A/C] rs6833755 4 122030864 [A/G] rs1027976 4 122039475 [T/G] rs11098602 4 122052641 [A/G] NM_001128843,NM_001244764,NM_024873 TNIP3,TNIP3,TNIP3 EXON Silent,Silent,Silent rs6846553 4 122053223 [T/C] NM_001128843,NM_001244764,NM_024873 TNIP3,TNIP3,TNIP3 EXON Silent,Silent,Silent rs1858291 4 122055956 [A/G] NM_001128843,NM_001244764,NM_024873 TNIP3,TNIP3,TNIP3 Silent,Silent,Silent rs3817171 4 122063735 [A/G] NM_001128843,NM_001244764,NM_024873 TNIP3,TNIP3,TNIP3 Silent,Silent,Silent rs959268 4 122074463 [A/C] NM_001128843,NM_001244764,NM_024873 TNIP3,TNIP3,TNIP3 Silent,Silent,Silent rs17051298 4 122075739 [T/C] NM_001128843,NM_001244764,NM_024873 TNIP3,TNIP3,TNIP3 EXON Synonymous_E223E,Synonymous_E230E,Synonymous_E153E rs10000692 4 122078317 [T/C] NM_001128843,NM_001244764,NM_024873 TNIP3,TNIP3,TNIP3 EXON Missense_K169E,Missense_K176E,Missense_K99E rs6821331 4 122083428 [A/G] NM_001128843,NM_001244764,NM_024873 TNIP3,TNIP3,TNIP3 Silent,Silent,Silent rs7661427 4 122088141 [A/G] NM_001128843,NM_001244764 TNIP3,TNIP3 Silent,Silent rs13129450 4 122091233 [T/G] NM_001128843,NM_001244764 TNIP3,TNIP3 Silent,Silent rs17051306 4 122095286 [T/C] NM_001128843,NM_001244764 TNIP3,TNIP3 Silent,Silent rs6838000 4 122096742 [A/G] NM_001128843,NM_001244764 TNIP3,TNIP3 Silent,Silent rs9784553 4 122100257 [A/G] NM_001128843,NM_001244764 TNIP3,TNIP3 Silent,Silent rs13116936 4 122126808 [T/G] NM_001128843,NM_001244764 TNIP3,TNIP3 Silent,Silent rs13104875 4 122137121 [T/C] NM_001128843,NM_001244764 TNIP3,TNIP3 Silent,Silent rs10518385 4 122142224 [T/C] NM_001244764 TNIP3 Silent rs6835704 4 122143664 [T/C] NM_001244764 TNIP3 Silent rs2278865 4 122151897 [T/C] rs7671286 4 122156142 [T/C] rs11938619 4 122161207 [A/G] rs12650479 4 122163552 [T/C] rs7663303 4 122170912 [A/G] rs9993738 4 122176770 [T/C] rs9997417 4 122181277 [T/G] rs17051324 4 122184678 [T/C] rs7693881 4 122184750 [T/C] rs7654307 4 122187618 [T/G] rs13128635 4 122187933 [A/G] rs4833711 4 122193376 [T/C] rs1986022 4 122197904 [T/C] rs7664875 4 122201508 [A/G] rs17051336 4 122203163 [A/G] rs12647412 4 122205406 [T/C] rs12642727 4 122219233 [T/C] rs4642269 4 122222233 [A/G] rs13119531 4 122226998 [A/G] rs12711093 4 122231301 [A/C] rs10222821 4 122235791 [T/G] rs4642270 4 122241609 [A/G] rs12639850 4 122244597 [A/G] rs11721375 4 122249743 [A/G] rs2302310 4 122250734 [A/G] NM_198179 QRFPR EXON Missense_L344S rs4273489 4 122257538 [A/G] NM_198179 QRFPR Silent rs2302309 4 122257950 [A/G] NM_198179 QRFPR Silent rs4490481 4 122258063 [A/G] NM_198179 QRFPR Silent rs35623795 4 122258950 [T/C] NM_198179 QRFPR Silent rs12499677 4 122263138 [A/G] NM_198179 QRFPR Silent rs7698313 4 122264663 [A/G] NM_198179 QRFPR Silent rs13110738 4 122268413 [A/G] NM_198179 QRFPR Silent rs13110590 4 122268517 [A/C] NM_198179 QRFPR Silent rs2090025 4 122274144 [T/C] NM_198179 QRFPR Silent rs11733055 4 122275299 [T/G] NM_198179 QRFPR Silent rs13114721 4 122281107 [A/G] NM_198179 QRFPR Silent rs17051344 4 122285263 [A/G] NM_198179 QRFPR Silent rs691192 4 122285315 [T/G] NM_198179 QRFPR Silent rs575465 4 122288645 [T/C] NM_198179 QRFPR Silent rs691626 4 122289863 [T/C] NM_198179 QRFPR Silent rs2013534 4 122291131 [T/G] NM_198179 QRFPR Silent rs691712 4 122296807 [T/C] NM_198179 QRFPR Silent rs12642360 4 122300413 [A/G] NM_198179 QRFPR Silent rs17438900 4 122301622 [A/C] NM_198179 QRFPR EXON Missense_F61V rs690731 4 122306748 [A/C] rs692496 4 122308022 [T/C] rs535465 4 122309865 [A/G] rs532774 4 122310161 [A/G] rs1513696 4 122310776 [T/C] rs691684 4 122310963 [T/C] rs7679475 4 122314040 [A/G] rs6857701 4 122315742 [T/C] rs17439459 4 122315993 [T/C] rs4425401 4 122324112 [A/G] rs17439730 4 122325187 [T/C] rs1513697 4 122333765 [A/C] rs17051351 4 122342575 [T/C] rs9884280 4 122343345 [T/C] rs691809 4 122343902 [T/C] rs488158 4 122348834 [A/C] rs6842836 4 122350537 [T/C] rs498307 4 122353707 [T/C] rs691345 4 122358044 [A/C] rs10010505 4 122361299 [A/G] rs10010429 4 122361381 [T/C] rs17051353 4 122361659 [A/C] rs12647248 4 122369141 [A/G] rs1022251 4 122369974 [A/C] rs577737 4 122370550 [A/G] rs692380 4 122370729 [A/C] rs12510951 4 122377715 [A/G] rs692157 4 122382834 [T/C] rs13123059 4 122391530 [T/C] rs1513702 4 122392108 [A/G] rs10028769 4 122393782 [T/C] rs10031780 4 122394649 [T/C] rs13137076 4 122395119 [T/C] rs6842940 4 122401640 [T/C] rs4833728 4 122406507 [T/C] rs1513707 4 122421393 [A/C] rs13124630 4 122423129 [A/C] rs10015843 4 122426180 [A/G] rs17382098 4 122426239 [A/G] rs10005328 4 122426251 [T/C] rs9993990 4 122426864 [A/C] rs4833736 4 122429378 [A/G] rs13138786 4 122430844 [T/C] rs7698292 4 122431338 [T/C] rs883029 4 122431579 [T/G] rs6828751 4 122436261 [T/C] rs17051364 4 122437789 [A/G] rs1016802 4 122438484 [T/C] rs13106184 4 122438628 [A/G] rs1877637 4 122440128 [T/G] rs12648087 4 122440829 [A/G] rs4833741 4 122446250 [T/C] rs12501209 4 122448971 [T/C] rs4833218 4 122449393 [A/G] rs4833219 4 122449490 [A/G] rs6840582 4 122450475 [T/C] rs7683438 4 122450852 [A/C] rs9994817 4 122451829 [T/C] rs4370152 4 122463069 [A/G] rs12504183 4 122473563 [A/G] rs982887 4 122475832 [T/C] rs4565102 4 122480241 [A/G] rs1480296 4 122482578 [A/G] rs6534295 4 122487647 [T/C] rs1159702 4 122494838 [T/C] rs11731548 4 122499665 [T/G] rs7690087 4 122502810 [T/C] rs6534300 4 122508654 [A/G] rs1480276 4 122510701 [T/C] rs17051373 4 122511492 [T/G] rs10022795 4 122511622 [A/G] rs10518393 4 122512853 [A/G] rs13114712 4 122515534 [T/C] rs6534302 4 122520868 [A/G] rs9685971 4 122525783 [A/G] rs7684836 4 122526728 [T/G] rs4490484 4 122529718 [A/C] rs3811745 4 122531359 [A/G] rs7654348 4 122532114 [T/G] rs6840518 4 122532992 [A/G] rs17442542 4 122533936 [T/C] rs4460015 4 122535735 [A/G] rs7675417 4 122544756 [A/G] rs4833753 4 122550874 [A/G] rs4522886 4 122551505 [T/G] rs11735972 4 122552373 [T/C] rs4460016 4 122555682 [A/C] rs11722834 4 122557052 [A/C] rs12499696 4 122557607 [A/G] rs2390235 4 122565377 [A/C] rs17051378 4 122565698 [T/C] rs11937669 4 122567739 [A/G] rs725882 4 122568322 [A/G] rs6846873 4 122569803 [A/G] rs10022259 4 122571226 [A/C] rs10003585 4 122572851 [T/C] rs6823721 4 122573054 [T/C] rs11937561 4 122574626 [T/C] rs17384008 4 122580875 [A/G] rs11098633 4 122583666 [A/G] rs9995119 4 122587804 [A/C] rs17718 4 122589283 [A/G] NM_001154 ANXA5 EXON Silent rs2306420 4 122591475 [A/G] NM_001154 ANXA5 Silent rs11098637 4 122600471 [T/G] NM_001154 ANXA5 Silent rs17449954 4 122607728 [T/C] NM_001154 ANXA5 Silent rs10518391 4 122607848 [T/C] NM_001154 ANXA5 Silent rs6857766 4 122611285 [A/G] NM_001154 ANXA5 Silent rs11731225 4 122613258 [T/C] NM_001154 ANXA5 Silent rs6830321 4 122614755 [T/C] NM_001154 ANXA5 Silent rs13145977 4 122616166 [T/C] NM_001154 ANXA5 Silent rs2306416 4 122617688 [T/C] NM_001154 ANXA5 Silent rs7680787 4 122624065 [T/C] rs9997310 4 122628680 [A/G] rs4833757 4 122633535 [A/G] rs1383228 4 122639133 [A/C] rs2892966 4 122644567 [T/C] rs1031923 4 122647904 [T/C] rs17051396 4 122653098 [A/G] rs11732306 4 122653300 [A/C] rs6838346 4 122656144 [A/G] rs2390227 4 122656714 [T/C] rs4833765 4 122657875 [A/G] rs17051398 4 122659257 [T/C] rs2706783 4 122659350 [T/C] rs2706784 4 122659704 [A/C] rs12650783 4 122662143 [T/C] rs28532673 4 122664323 [A/G] rs4629472 4 122669747 [T/C] rs10024052 4 122671944 [A/G] rs11934307 4 122677514 [A/G] rs11937861 4 122680075 [T/C] rs4370153 4 122683007 [A/G] NM_152399,NM_001317837,NM_001317839,NM_001317841,NM_001317842,NM_001317838 TMEM155,TMEM155,TMEM155,TMEM155,TMEM155,TMEM155 EXON Missense_A11V,Missense_A11V,Missense_A11V,Silent,Silent,Missense_A11V rs4833233 4 122688744 [A/G] rs6534321 4 122692023 [T/C] rs7687226 4 122694087 [A/G] rs4519820 4 122702459 [T/C] rs6838153 4 122720999 [A/G] rs3828485 4 122722368 [A/G] rs6836544 4 122726073 [T/C] NM_001034194,NM_005033 EXOSC9,EXOSC9 Silent,Silent rs1803183 4 122735142 [A/G] NM_001034194,NM_005033 EXOSC9,EXOSC9 EXON Missense_I366V,Missense_I366V rs2071486 4 122740162 [T/C] NM_001237 CCNA2 Silent rs769243 4 122741807 [T/C] NM_001237 CCNA2 EXON Synonymous_Q228Q rs769242 4 122742217 [T/C] NM_001237 CCNA2 EXON Missense_I163V rs3217760 4 122743793 [T/G] NM_001237 CCNA2 EXON Synonymous_P74P rs769240 4 122744067 [A/C] NM_001237 CCNA2 Silent rs1048433 4 122748996 [A/C] NM_176824,NM_018190 BBS7,BBS7 EXON Silent,Silent rs1507994 4 122749541 [T/C] NM_176824,NM_018190 BBS7,BBS7 Silent,Silent rs13145213 4 122750079 [T/C] NM_176824,NM_018190 BBS7,BBS7 Silent,Silent rs12499222 4 122774917 [A/G] NM_176824,NM_018190 BBS7,BBS7 Silent,Silent rs6838198 4 122781263 [A/C] NM_176824,NM_018190 BBS7,BBS7 Silent,Silent rs10518290 4 122805872 [A/G] NM_003305,NM_001130698 TRPC3,TRPC3 Silent,Silent rs11726196 4 122806228 [A/C] NM_003305,NM_001130698 TRPC3,TRPC3 Silent,Silent rs12502635 4 122813459 [A/G] NM_003305,NM_001130698 TRPC3,TRPC3 Silent,Silent rs2135976 4 122816181 [T/C] NM_003305,NM_001130698 TRPC3,TRPC3 Silent,Silent rs11732666 4 122824052 [T/C] NM_003305,NM_001130698 TRPC3,TRPC3 EXON Synonymous_R733R,Synonymous_R806R rs17517624 4 122824591 [T/C] NM_003305,NM_001130698 TRPC3,TRPC3 Silent,Silent rs3762839 4 122825364 [A/C] NM_003305,NM_001130698 TRPC3,TRPC3 Silent,Silent rs884701 4 122830406 [A/G] NM_003305,NM_001130698 TRPC3,TRPC3 Silent,Silent rs13127488 4 122830800 [A/G] NM_003305,NM_001130698 TRPC3,TRPC3 Silent,Silent rs906496 4 122833314 [T/C] NM_003305,NM_001130698 TRPC3,TRPC3 Silent,Silent rs4292355 4 122842267 [T/C] NM_003305,NM_001130698 TRPC3,TRPC3 Silent,Silent rs12644087 4 122844819 [T/C] NM_003305,NM_001130698 TRPC3,TRPC3 Silent,Silent rs6841843 4 122857568 [T/C] NM_001130698 TRPC3 Silent rs4833779 4 122861426 [T/C] NM_001130698 TRPC3 Silent rs950574 4 122864241 [A/G] NM_001130698 TRPC3 Silent rs970349 4 122871632 [A/G] NM_001130698 TRPC3 Silent rs4001038 4 122886240 [T/C] rs1358229 4 122896734 [T/C] rs6838639 4 122899165 [A/G] rs13109219 4 122900529 [T/C] rs9999992 4 122902084 [A/G] rs6817255 4 122902923 [T/G] rs11098653 4 122903090 [T/C] rs13130390 4 122903206 [A/G] rs11098654 4 122909415 [T/C] rs17596104 4 122924236 [T/C] rs7340812 4 122925529 [A/C] rs4833241 4 122933691 [T/C] rs1965582 4 122947939 [A/G] rs10004294 4 122949052 [A/C] rs10016562 4 122949327 [T/G] rs12649045 4 122957607 [T/C] rs4833798 4 122959398 [T/C] rs6850993 4 122962378 [T/C] rs12650123 4 122962834 [T/C] rs2204586 4 122965655 [T/C] rs17517905 4 122966128 [T/G] rs13114230 4 122971505 [A/C] rs10516615 4 122974607 [A/G] rs10516616 4 122974644 [A/G] rs6534337 4 122974755 [T/C] rs10155183 4 122975004 [T/C] rs6840372 4 122978844 [T/C] rs7661311 4 122982259 [T/C] rs1880864 4 122987188 [A/G] rs13116766 4 122989473 [A/C] rs4833808 4 122992499 [T/C] rs10009575 4 122993170 [A/C] rs1526926 4 122994218 [A/C] rs941130 4 123001769 [A/G] rs3108394 4 123003141 [A/G] rs4279237 4 123009174 [A/G] rs13132933 4 123010587 [T/C] rs11936230 4 123016755 [T/C] rs4833810 4 123018390 [T/C] rs3108396 4 123021560 [T/G] rs6534338 4 123026869 [T/C] rs4833811 4 123027723 [T/C] rs17644013 4 123049637 [A/G] rs10024144 4 123066575 [T/C] rs11938795 4 123073009 [T/C] rs10012089 4 123078112 [T/C] rs10005516 4 123084874 [A/G] rs10471017 4 123090820 [A/G] rs10021037 4 123095703 [T/C] NM_015312 KIAA1109 Silent rs7682281 4 123096486 [T/C] NM_015312 KIAA1109 Silent rs13151961 4 123115502 [A/G] NM_015312 KIAA1109 Silent rs7664452 4 123146225 [T/G] NM_015312 KIAA1109 Silent rs6848868 4 123150286 [T/C] NM_015312 KIAA1109 EXON Missense_I978T rs11734090 4 123228113 [T/C] NM_015312 KIAA1109 Silent rs7688384 4 123229132 [T/C] NM_015312 KIAA1109 EXON Synonymous_A3290A rs10027161 4 123250384 [A/C] NM_015312 KIAA1109 Silent rs2306369 4 123268859 [A/G] NM_015312 KIAA1109 EXON Missense_T4352A rs10021203 4 123272884 [A/G] NM_015312 KIAA1109 Silent rs1127348 4 123280860 [T/C] NM_015312 KIAA1109 EXON Synonymous_H4928H rs17005693 4 123281293 [T/C] NM_015312 KIAA1109 Silent rs34135604 4 123283993 [A/G] rs10025646 4 123297847 [A/G] rs10028661 4 123298789 [A/G] rs4833247 4 123298910 [A/G] rs10032704 4 123306223 [T/C] NM_139243,NM_001159295,NM_001159285 ADAD1,ADAD1,ADAD1 Silent,Silent,Silent rs17388568 4 123329362 [A/G] NM_139243,NM_001159295,NM_001159285 ADAD1,ADAD1,ADAD1 Silent,Silent,Silent rs12499753 4 123333177 [T/C] NM_139243,NM_001159295,NM_001159285 ADAD1,ADAD1,ADAD1 Silent,Silent,Silent rs7684187 4 123341159 [A/G] NM_139243,NM_001159295,NM_001159285 ADAD1,ADAD1,ADAD1 Silent,Silent,Silent rs1383043 4 123342616 [A/G] NM_139243,NM_001159295,NM_001159285 ADAD1,ADAD1,ADAD1 Silent,Silent,Silent rs11732095 4 123348345 [A/G] NM_139243,NM_001159295,NM_001159285 ADAD1,ADAD1,ADAD1 Silent,Silent,Silent rs1021010 4 123354046 [A/G] rs28704777 4 123367509 [A/G] rs10027390 4 123368516 [T/C] rs1479923 4 123370387 [A/G] rs11575812 4 123371049 [A/G] rs2069763 4 123377482 [A/C] NM_000586 IL2 EXON Synonymous_L38L rs1383045 4 123380765 [A/G] rs10857092 4 123389219 [A/G] rs6848139 4 123395041 [A/C] rs11946129 4 123427639 [A/G] rs6852535 4 123478716 [A/G] rs1512973 4 123506056 [A/G] rs11098666 4 123507914 [A/G] rs12642902 4 123508501 [A/G] rs6822844 4 123509421 [T/G] rs975405 4 123521180 [A/G] rs7682241 4 123523875 [T/G] rs17886348 4 123533820 [T/C] NM_021803,NM_001207006 IL21,IL21 EXON Silent,Silent rs17879298 4 123533834 [A/G] NM_021803,NM_001207006 IL21,IL21 EXON Silent,Silent rs4833837 4 123536963 [A/G] NM_021803,NM_001207006 IL21,IL21 EXON Synonymous_C78C,Synonymous_C78C rs17005931 4 123545648 [T/C] NR_104126 IL21-AS1 Silent rs4295278 4 123547541 [T/C] NR_104126 IL21-AS1 EXON Silent rs17005934 4 123549699 [T/C] NR_104126 IL21-AS1 Silent rs4833838 4 123550698 [A/G] NR_104126 IL21-AS1 Silent rs2893008 4 123552814 [A/G] NR_104126 IL21-AS1 Silent rs6840978 4 123554707 [T/C] NR_104126 IL21-AS1 Silent rs17391154 4 123556193 [A/C] NR_104126 IL21-AS1 Silent rs2137497 4 123558254 [T/G] NR_104126 IL21-AS1 Silent rs2390352 4 123558330 [T/C] NR_104126 IL21-AS1 Silent rs1512970 4 123561067 [T/C] NR_104126 IL21-AS1 Silent rs6534355 4 123561650 [T/C] NR_104126 IL21-AS1 Silent rs1022234 4 123563078 [A/G] NR_104126 IL21-AS1 Silent rs1533236 4 123564458 [T/C] NR_104126 IL21-AS1 Silent rs10518405 4 123580354 [A/C] NR_104126 IL21-AS1 Silent rs6844999 4 123581235 [T/G] NR_104126 IL21-AS1 Silent rs10518400 4 123582426 [A/G] NR_104126 IL21-AS1 Silent rs6836610 4 123601697 [A/G] NR_104126 IL21-AS1 Silent rs309388 4 123610112 [T/C] NR_104126 IL21-AS1 EXON Silent rs309398 4 123614762 [T/C] rs13101575 4 123617561 [A/G] rs309414 4 123620912 [T/G] rs13353661 4 123623830 [A/C] rs1026157 4 123623893 [T/G] rs416556 4 123629427 [A/C] rs1512974 4 123631308 [A/G] rs11940552 4 123643662 [T/C] rs13138426 4 123652580 [T/C] NR_024041 CETN4P Silent rs17006077 4 123663098 [A/G] NM_001178007,NM_152618 BBS12,BBS12 EXON Synonymous_Q17Q,Synonymous_Q17Q rs309369 4 123663425 [T/G] NM_001178007,NM_152618 BBS12,BBS12 EXON Missense_E126D,Missense_E126D rs309370 4 123664204 [A/G] NM_001178007,NM_152618 BBS12,BBS12 EXON Missense_R386Q,Missense_R386Q rs309371 4 123664247 [A/G] NM_001178007,NM_152618 BBS12,BBS12 EXON Synonymous_V400V,Synonymous_V400V rs2292493 4 123664445 [T/C] NM_001178007,NM_152618 BBS12,BBS12 EXON Synonymous_G466G,Synonymous_G466G rs13135778 4 123664446 [A/G] NM_001178007,NM_152618 BBS12,BBS12 EXON Missense_D467N,Missense_D467N rs13102440 4 123664919 [A/G] NM_001178007,NM_152618 BBS12,BBS12 EXON Synonymous_Q624Q,Synonymous_Q624Q rs4833843 4 123665428 [A/G] NM_001178007,NM_152618 BBS12,BBS12 EXON Silent,Silent rs7690568 4 123666777 [A/C] rs4833844 4 123668544 [T/C] rs6811183 4 123671551 [T/G] rs13142203 4 123679002 [T/C] rs17006152 4 123704607 [A/C] rs921301 4 123705387 [T/C] rs10005301 4 123715055 [T/C] rs13113055 4 123715828 [T/C] rs11939650 4 123718247 [T/C] rs308447 4 123738546 [T/C] rs308394 4 123746883 [T/C] rs1449683 4 123748086 [T/C] NM_002006,NM_001361665 FGF2,FGF2 EXON Synonymous_S52S,Silent rs308412 4 123752017 [T/G] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs308420 4 123767943 [A/G] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs308434 4 123771828 [T/C] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs308435 4 123772018 [A/C] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs308438 4 123772887 [T/C] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs308439 4 123773579 [T/G] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs308441 4 123774065 [T/C] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs17472986 4 123774832 [A/G] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs308443 4 123775767 [A/G] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs17407577 4 123779341 [T/C] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs1960669 4 123782568 [A/C] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs308388 4 123787079 [A/G] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs7694627 4 123788495 [T/C] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs17006255 4 123798993 [A/C] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs10028204 4 123799987 [A/G] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs17408557 4 123800617 [A/G] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs10452197 4 123810328 [T/C] NM_002006,NM_001361665 FGF2,FGF2 Silent,Silent rs3804156 4 123813655 [A/G] NM_002006,NM_001361665 FGF2,FGF2 EXON Silent,Silent rs1048201 4 123814308 [T/C] NM_002006,NM_001361665,NM_007083,NM_198041 FGF2,FGF2,NUDT6,NUDT6 EXON Silent,Silent,Missense_R209Q,Missense_R40Q rs3804158 4 123814900 [A/G] NM_002006,NM_001361665,NM_007083,NM_198041 FGF2,FGF2,NUDT6,NUDT6 EXON Silent,Silent,Silent,Silent rs6854081 4 123816707 [T/G] NM_002006,NM_001361665,NM_007083,NM_198041 FGF2,FGF2,NUDT6,NUDT6 EXON Silent,Silent,Silent,Silent rs3747676 4 123818074 [T/C] NM_002006,NM_001361665,NM_007083,NM_198041 FGF2,FGF2,NUDT6,NUDT6 EXON Silent,Silent,Silent,Silent rs11737764 4 123826780 [T/C] NM_007083,NM_198041 NUDT6,NUDT6 Silent,Silent rs1458758 4 123835879 [T/G] NM_007083,NM_198041 NUDT6,NUDT6 Silent,Silent rs12648093 4 123838758 [A/G] NM_007083,NM_198041 NUDT6,NUDT6 EXON Missense_C114R,Silent rs17006315 4 123839009 [A/C] NM_007083,NM_198041 NUDT6,NUDT6 Silent,Silent rs898091 4 123840064 [A/G] NM_007083,NM_198041 NUDT6,NUDT6 Silent,Silent rs13134412 4 123843716 [T/C] NM_007083,NM_198041 NUDT6,NUDT6 EXON Synonymous_P4P,Silent rs10222773 4 123852184 [A/C] NM_145207,NM_001345856,NM_001317799 SPATA5,SPATA5,SPATA5 Silent,Silent,Silent rs7698445 4 123859106 [T/G] NM_145207,NM_001345856,NM_001317799 SPATA5,SPATA5,SPATA5 Silent,Silent,Silent rs6534369 4 123868456 [T/C] NM_145207,NM_001345856,NM_001317799 SPATA5,SPATA5,SPATA5 EXON Synonymous_L509L,Synonymous_L508L,Synonymous_L508L rs13106595 4 123873534 [A/G] NM_145207,NM_001345856,NM_001317799 SPATA5,SPATA5,SPATA5 Silent,Silent,Silent rs906833 4 123881864 [T/C] NM_145207,NM_001345856,NM_001317799 SPATA5,SPATA5,SPATA5 Silent,Silent,Silent rs7673580 4 123885815 [T/C] NM_145207,NM_001345856,NM_001317799 SPATA5,SPATA5,SPATA5 Silent,Silent,Silent rs1467994 4 123890773 [A/C] NM_145207,NM_001345856,NM_001317799 SPATA5,SPATA5,SPATA5 Silent,Silent,Silent rs34850283 4 123913992 [T/C] NM_145207,NM_001345856,NM_001317799 SPATA5,SPATA5,SPATA5 Silent,Silent,Silent rs1472949 4 123949556 [A/G] NM_145207,NM_001345856,NM_001317799 SPATA5,SPATA5,SPATA5 EXON Silent,Silent,Synonymous_G694G rs11731720 4 123976639 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs12650805 4 123984242 [T/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs12650569 4 123989201 [A/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs11937761 4 124005579 [A/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs433220 4 124008458 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs12500537 4 124008817 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs412925 4 124015188 [A/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs10518410 4 124018404 [A/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs307060 4 124028416 [A/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs1428267 4 124047573 [A/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs7674347 4 124055908 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs303084 4 124066948 [A/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs6853344 4 124068453 [T/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs304653 4 124080712 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs1025286 4 124081430 [T/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs11934706 4 124082838 [A/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs304650 4 124083918 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs17006613 4 124100028 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs303130 4 124107641 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs304658 4 124108270 [A/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs11944380 4 124119834 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs303096 4 124127581 [A/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs303100 4 124132528 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs2561151 4 124140719 [A/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs4479722 4 124154217 [A/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs303143 4 124155197 [A/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs11940736 4 124171702 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs991183 4 124173635 [A/G] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs11735364 4 124185679 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs1031135 4 124192894 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs17006770 4 124206187 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs13109534 4 124211262 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 Silent,Silent rs6832894 4 124239525 [T/C] NM_145207,NM_001345856 SPATA5,SPATA5 EXON Silent,Silent rs2291934 4 124246965 [T/C] rs300559 4 124256835 [A/G] rs7677059 4 124257091 [T/C] rs871648 4 124267444 [A/G] rs7655411 4 124275630 [A/G] rs879905 4 124282603 [T/G] rs1027374 4 124283138 [T/C] rs6845023 4 124285735 [A/G] rs7659671 4 124288412 [T/G] rs300550 4 124291946 [A/C] rs17006884 4 124292330 [T/G] rs11098708 4 124297264 [T/C] rs300553 4 124297449 [T/C] rs300556 4 124305017 [T/C] rs6836221 4 124315710 [T/G] rs300567 4 124316684 [A/G] rs300569 4 124319144 [T/C] NM_199327,NM_001258038 SPRY1,SPRY1 Silent,Silent rs300572 4 124320924 [A/G] NM_199327,NM_001258038,NM_001258039,NM_005841 SPRY1,SPRY1,SPRY1,SPRY1 EXON Silent,Silent,Silent,Silent rs300574 4 124323738 [T/C] NM_199327,NM_001258038,NM_001258039,NM_005841 SPRY1,SPRY1,SPRY1,SPRY1 EXON Silent,Silent,Silent,Silent rs1353305 4 124326814 [A/C] rs1546249 4 124328791 [A/C] rs7665238 4 124329732 [A/G] rs923982 4 124334279 [T/C] rs12505913 4 124337522 [A/G] rs13124930 4 124340706 [A/G] rs2390522 4 124342410 [A/G] rs10857095 4 124343118 [T/C] rs12233855 4 124344717 [T/C] rs10021762 4 124345346 [A/G] rs11098710 4 124353489 [T/C] rs17006926 4 124359022 [T/C] rs6534401 4 124359046 [T/G] rs17006928 4 124362035 [T/C] rs17006932 4 124368159 [A/G] rs3860074 4 124368370 [A/G] rs11734331 4 124371328 [A/G] rs13139048 4 124372645 [A/G] rs7677413 4 124375248 [T/C] rs11732507 4 124387408 [A/G] rs17807333 4 124387459 [A/G] rs10776501 4 124387479 [A/G] rs7697652 4 124387560 [A/G] rs10029753 4 124389966 [A/G] rs17745658 4 124393598 [A/G] rs6534407 4 124395024 [A/G] rs1452731 4 124397309 [A/G] rs12233795 4 124397732 [A/C] rs1349683 4 124399060 [T/C] rs737010 4 124399672 [A/C] rs737009 4 124399996 [A/G] rs1901694 4 124402023 [A/G] rs6831251 4 124403102 [T/C] rs10471022 4 124410268 [A/G] rs896678 4 124417151 [T/C] rs896676 4 124417350 [A/G] rs1947372 4 124423491 [A/G] rs7688738 4 124426163 [T/G] rs4833925 4 124430104 [T/C] rs17007024 4 124430794 [T/C] rs17007028 4 124437413 [T/C] rs1993191 4 124437842 [A/C] rs17007051 4 124443473 [T/G] rs10461205 4 124450148 [T/C] rs7670704 4 124469200 [T/C] rs10011590 4 124473935 [T/C] rs4076851 4 124477700 [A/G] rs4833930 4 124496348 [T/C] rs17007092 4 124501466 [A/G] rs10019036 4 124506056 [T/C] rs1806533 4 124509674 [A/G] rs17007100 4 124510605 [A/G] rs6534418 4 124512827 [T/C] rs2553364 4 124519432 [A/G] rs752499 4 124527958 [T/C] rs752501 4 124528377 [A/G] rs10017009 4 124530321 [T/C] rs2589850 4 124531422 [T/C] rs10003701 4 124534956 [T/C] rs17809301 4 124538705 [T/G] rs13115814 4 124545508 [A/C] rs2162093 4 124548625 [T/C] rs2589864 4 124550693 [T/C] rs17809737 4 124561823 [T/C] rs17753395 4 124564632 [A/G] rs1425419 4 124565964 [T/C] rs7695956 4 124570408 [A/G] rs2589858 4 124570507 [A/G] rs6534420 4 124574008 [A/G] NR_027105 LINC01091 EXON Silent rs17007172 4 124581413 [T/C] NR_027105 LINC01091 Silent rs9998540 4 124588333 [T/C] NR_027105 LINC01091 Silent rs2553355 4 124590869 [A/G] NR_027105 LINC01091 Silent rs12509315 4 124592367 [T/C] NR_027105 LINC01091 Silent rs2589838 4 124592723 [T/G] NR_027105 LINC01091 Silent rs9991619 4 124593136 [A/G] NR_027105 LINC01091 Silent rs2589845 4 124608621 [T/C] NR_027105 LINC01091 Silent rs10776504 4 124615411 [T/G] NR_027105 LINC01091 Silent rs890180 4 124621650 [T/C] NR_027105 LINC01091 Silent rs12500929 4 124623291 [A/G] NR_027105 LINC01091 Silent rs11723044 4 124627790 [T/C] NR_027105 LINC01091 Silent rs13117812 4 124628029 [A/G] NR_027105 LINC01091 Silent rs1425416 4 124628278 [A/G] NR_027105 LINC01091 Silent rs1834378 4 124650005 [A/G] NR_027105 LINC01091 Silent rs11098717 4 124652559 [T/C] NR_027105 LINC01091 Silent rs4833940 4 124654530 [T/C] NR_027105 LINC01091 Silent rs4833288 4 124654693 [T/C] NR_027105 LINC01091 Silent rs17007240 4 124659199 [T/C] NR_027105 LINC01091 Silent rs4833947 4 124672450 [A/G] NR_027105 LINC01091 Silent rs2194865 4 124673938 [A/G] NR_027105 LINC01091 Silent rs12233817 4 124675264 [A/C] NR_027105 LINC01091 Silent rs6828406 4 124679431 [A/G] NR_027105 LINC01091 Silent rs1425406 4 124683891 [A/G] NR_027105 LINC01091 Silent rs10006182 4 124696247 [A/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs3097925 4 124704038 [T/C] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs1433219 4 124706056 [A/C] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs1433218 4 124707000 [A/C] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs7692299 4 124710584 [T/C] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs4833953 4 124711445 [A/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs6821590 4 124713216 [T/C] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs2390586 4 124718116 [T/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs3097935 4 124718998 [A/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs3097914 4 124729590 [A/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs10028801 4 124731732 [A/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs1433216 4 124733305 [A/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs3113387 4 124741086 [A/C] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs9991633 4 124742689 [T/C] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs1347188 4 124743259 [A/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs1991839 4 124745047 [A/C] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs978534 4 124749377 [T/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs1433212 4 124752974 [A/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs17491036 4 124754548 [T/C] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs1347184 4 124757420 [A/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs1433211 4 124763465 [A/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs3113390 4 124766115 [T/C] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs1036253 4 124767640 [T/C] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs4449426 4 124770843 [A/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs4340803 4 124770865 [A/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs11731103 4 124775267 [T/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs3113392 4 124775472 [T/C] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs12640716 4 124775549 [A/C] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs3113396 4 124784586 [A/G] NR_027105,NR_027106 LINC01091,LINC01091 Silent,Silent rs17425951 4 124788456 [A/G] NR_027105 LINC01091 Silent rs1560738 4 124791509 [T/C] NR_027105 LINC01091 Silent rs986345 4 124794203 [T/C] NR_027105 LINC01091 Silent rs17491837 4 124797438 [T/C] NR_027105 LINC01091 Silent rs1433225 4 124802131 [A/G] NR_027105 LINC01091 Silent rs1347189 4 124802903 [A/G] NR_027105 LINC01091 Silent rs17007551 4 124807727 [A/G] NR_027105 LINC01091 Silent rs17007553 4 124807935 [T/C] NR_027105 LINC01091 Silent rs9991120 4 124809136 [A/C] NR_027105 LINC01091 Silent rs1433223 4 124810078 [A/C] NR_027105 LINC01091 Silent rs17492375 4 124812897 [T/C] NR_027105 LINC01091 Silent rs7691701 4 124819109 [T/C] NR_027105 LINC01091 Silent rs1857 4 124819486 [A/C] NR_027105 LINC01091 Silent rs1433220 4 124833001 [A/G] NR_027105 LINC01091 Silent rs3113378 4 124834717 [T/G] NR_027105 LINC01091 Silent rs1519242 4 124844059 [A/C] NR_027105 LINC01091 Silent rs17007605 4 124846679 [T/G] NR_027105 LINC01091 Silent rs1878989 4 124847240 [T/C] NR_027105 LINC01091 Silent rs10034152 4 124847477 [T/C] NR_027105 LINC01091 Silent rs13151047 4 124850901 [A/G] NR_027105 LINC01091 Silent rs6838706 4 124851510 [A/G] NR_027105 LINC01091 EXON Silent rs1048174 4 124851726 [T/C] NR_027105 LINC01091 EXON Silent rs11946288 4 124855529 [A/G] rs17007632 4 124857954 [A/C] rs1022373 4 124859063 [A/G] rs10027482 4 124861428 [A/G] rs2390610 4 124865191 [A/G] rs1996580 4 124871513 [A/G] rs4833296 4 124874115 [T/C] rs17007675 4 124875936 [T/C] rs1519238 4 124876173 [A/C] rs9998439 4 124888965 [A/G] rs1474147 4 124890766 [T/C] rs9307533 4 124891140 [T/C] rs4833961 4 124891317 [A/G] rs11727463 4 124904592 [A/G] rs9307535 4 124905690 [A/C] rs908822 4 124906257 [T/C] rs1519225 4 124910861 [T/C] rs2893068 4 124926477 [T/C] rs12641524 4 124929001 [A/C] rs10018559 4 124946684 [T/C] rs17756952 4 124955670 [A/C] rs1850756 4 124965262 [A/C] rs10003267 4 124966525 [T/C] rs17007771 4 124970239 [A/G] rs17813612 4 124974957 [T/C] rs17007781 4 124977314 [T/C] rs1519243 4 124980267 [A/G] rs13112125 4 124983047 [T/C] rs962250 4 124986691 [T/C] rs10007602 4 124992645 [A/G] rs28624926 4 124993933 [A/G] rs4371629 4 125013856 [T/C] rs12647636 4 125017034 [T/C] rs10029877 4 125020390 [T/C] rs13152069 4 125034218 [T/C] rs4421000 4 125037794 [T/C] rs11945388 4 125046178 [T/C] rs11098739 4 125077863 [T/C] rs893558 4 125078861 [A/G] rs11933201 4 125095213 [A/G] rs17007871 4 125102345 [A/G] rs7664648 4 125104155 [A/G] rs6834028 4 125109084 [A/G] rs960925 4 125120257 [A/G] rs17007911 4 125127477 [T/C] rs499876 4 125129621 [A/G] rs10027705 4 125132433 [A/G] rs11937163 4 125133465 [A/G] rs1356837 4 125141551 [T/G] rs1520323 4 125146503 [T/C] rs13150117 4 125157019 [T/G] rs1123772 4 125157264 [T/C] rs11727483 4 125168089 [T/C] rs7680675 4 125175239 [A/G] rs725001 4 125188048 [T/C] rs17007972 4 125200741 [A/G] rs13145092 4 125209067 [T/C] rs17759829 4 125214511 [A/C] rs11735374 4 125220846 [A/G] rs10518427 4 125225084 [T/C] rs17816583 4 125225107 [T/C] rs13137088 4 125241747 [T/C] rs2168692 4 125249002 [T/C] rs662007 4 125253161 [T/C] rs2125000 4 125265313 [T/C] rs672858 4 125266797 [A/G] rs593371 4 125268531 [A/G] rs640246 4 125280852 [A/G] rs4833978 4 125295432 [T/C] rs9999775 4 125296033 [T/C] rs1159819 4 125298963 [A/G] rs2390684 4 125303951 [A/G] rs1492759 4 125310187 [A/G] rs1523504 4 125318885 [T/C] rs17008117 4 125320611 [T/C] rs1826424 4 125323828 [T/G] rs1851689 4 125326845 [A/G] rs7691579 4 125332916 [T/C] rs7661156 4 125355040 [A/G] rs7655016 4 125361767 [A/G] rs12506469 4 125371187 [A/G] rs6839627 4 125379709 [T/C] rs11936470 4 125380922 [A/G] rs4833302 4 125388177 [T/G] rs17008220 4 125391283 [T/C] rs13119813 4 125399775 [T/C] rs962939 4 125404239 [T/C] rs1492753 4 125421325 [A/G] NR_110838 LINC02516 EXON Silent rs10857100 4 125423945 [T/C] NR_110838 LINC02516 Silent rs6848373 4 125426113 [T/C] NR_110838 LINC02516 Silent rs12641839 4 125427661 [T/C] NR_110838 LINC02516 Silent rs101927 4 125435781 [T/C] NR_110838 LINC02516 Silent rs312508 4 125437668 [T/C] NR_110838 LINC02516 Silent rs17008280 4 125440570 [A/C] NR_110838 LINC02516 Silent rs312501 4 125441281 [A/C] NR_110838 LINC02516 Silent rs17008303 4 125445182 [T/C] NR_110838 LINC02516 Silent rs312492 4 125448257 [A/G] NR_110838 LINC02516 Silent rs312493 4 125448288 [T/C] NR_110838 LINC02516 Silent rs10029005 4 125451364 [A/G] NR_110838 LINC02516 Silent rs1509524 4 125455038 [A/G] NR_110838 LINC02516 Silent rs11946186 4 125457073 [T/C] NR_110838 LINC02516 Silent rs975107 4 125462793 [T/C] NR_110838 LINC02516 Silent rs7666278 4 125463533 [A/G] NR_110838 LINC02516 Silent rs1567396 4 125465163 [A/G] NR_110838 LINC02516 Silent rs4423888 4 125475882 [A/C] NR_110838 LINC02516 Silent rs558208 4 125479073 [T/C] NR_110838 LINC02516 Silent rs1092825 4 125480782 [A/G] rs491645 4 125484598 [T/C] rs9994125 4 125484781 [A/G] rs508410 4 125494504 [A/G] rs12643325 4 125497913 [A/G] rs7677431 4 125500592 [T/G] rs17008385 4 125511115 [T/C] rs2048265 4 125512711 [T/C] rs4833990 4 125513521 [T/C] rs12649449 4 125515296 [T/G] rs7689192 4 125518999 [T/C] rs4833993 4 125519380 [T/C] rs1390079 4 125523042 [T/C] rs1498012 4 125526281 [T/C] rs6846249 4 125531787 [A/C] rs9996039 4 125544726 [T/G] rs12504009 4 125553855 [T/C] rs870741 4 125554113 [A/C] rs10006893 4 125582871 [A/G] rs7675483 4 125584268 [A/G] rs3172524 4 125587561 [T/G] NM_020337,NM_001167882 ANKRD50,ANKRD50 EXON Silent,Silent rs1874748 4 125590478 [T/C] NM_020337,NM_001167882 ANKRD50,ANKRD50 EXON Synonymous_P1318P,Synonymous_P1139P rs3733471 4 125591687 [A/G] NM_020337,NM_001167882 ANKRD50,ANKRD50 EXON Synonymous_N915N,Synonymous_N736N rs3733472 4 125592440 [T/C] NM_020337,NM_001167882 ANKRD50,ANKRD50 EXON Synonymous_L664L,Synonymous_L485L rs7656458 4 125602470 [T/C] NM_020337,NM_001167882 ANKRD50,ANKRD50 Silent,Silent rs13110120 4 125610859 [T/C] NM_020337,NM_001167882 ANKRD50,ANKRD50 Silent,Silent rs13435256 4 125619501 [A/C] NM_020337,NM_001167882 ANKRD50,ANKRD50 Silent,Silent rs2036204 4 125620031 [A/G] NM_020337,NM_001167882 ANKRD50,ANKRD50 Silent,Silent rs2036205 4 125624349 [A/G] NM_020337,NM_001167882 ANKRD50,ANKRD50 Silent,Silent rs10025996 4 125636426 [T/C] rs17008503 4 125637940 [T/C] rs1027497 4 125640907 [A/G] rs11728675 4 125642349 [A/C] rs11098769 4 125649024 [T/C] rs10015950 4 125649275 [A/G] rs9993784 4 125649621 [T/C] rs10518438 4 125652879 [T/C] rs10518436 4 125653594 [T/C] rs17008527 4 125656446 [T/C] rs17772791 4 125659471 [T/C] rs10008933 4 125659601 [A/G] rs1498016 4 125662969 [A/C] rs13102814 4 125666014 [A/C] rs6841569 4 125666719 [T/C] rs10020316 4 125668245 [A/G] rs11722399 4 125670010 [T/C] rs2036203 4 125675055 [A/G] rs1506551 4 125683296 [A/G] rs17008575 4 125686468 [A/G] rs17008580 4 125687748 [A/G] rs313993 4 125691367 [T/C] rs10518450 4 125707202 [A/G] rs17008594 4 125707389 [T/C] rs993704 4 125712060 [A/G] rs11931944 4 125720431 [A/G] rs6829814 4 125724482 [T/G] rs10518444 4 125726204 [T/C] rs10518443 4 125728477 [A/G] rs10016531 4 125728562 [T/C] rs10029225 4 125732734 [T/C] rs1543936 4 125746220 [T/C] rs11934333 4 125748686 [T/C] rs1848056 4 125755019 [T/C] rs11939370 4 125761802 [A/C] rs9997902 4 125763629 [A/G] rs1395330 4 125767985 [A/G] rs13124340 4 125769617 [T/G] rs1395331 4 125771540 [A/G] rs17008684 4 125773999 [T/C] rs17786141 4 125781529 [T/C] rs2390740 4 125784021 [T/G] rs7695725 4 125786036 [T/C] rs4833310 4 125788673 [T/C] rs13148187 4 125790657 [T/C] rs2086765 4 125791252 [A/G] rs10034686 4 125796096 [A/G] rs1395326 4 125804479 [T/C] rs9993168 4 125807868 [A/G] rs1506543 4 125811847 [T/G] rs1995626 4 125812575 [T/C] rs10033902 4 125813232 [T/C] rs16997819 4 125813774 [T/C] rs9990572 4 125815138 [T/C] rs6838702 4 125831214 [A/G] rs7698052 4 125835783 [T/C] rs17008804 4 125840550 [T/C] rs7356273 4 125841892 [T/C] rs1909100 4 125842481 [T/C] rs10470922 4 125842539 [A/G] rs10518455 4 125842552 [T/C] rs1483594 4 125842641 [A/G] rs931651 4 125844550 [T/C] rs7662742 4 125846011 [A/G] rs6847509 4 125849986 [A/G] rs1483599 4 125853748 [T/C] rs6852823 4 125856465 [A/G] rs9997123 4 125856511 [T/C] rs10022194 4 125863974 [T/G] rs10022344 4 125864319 [T/C] rs11733185 4 125864597 [T/C] rs2170743 4 125864653 [T/C] rs1021629 4 125865096 [A/G] rs1021631 4 125865319 [A/C] rs7684522 4 125874154 [A/C] rs1498049 4 125875734 [T/C] rs13133741 4 125876427 [T/C] rs17008912 4 125878081 [A/C] rs11723954 4 125880959 [A/G] rs6852293 4 125886011 [A/G] rs12640447 4 125892629 [A/C] rs12331172 4 125894102 [A/C] rs4834012 4 125907632 [A/G] rs11939336 4 125914639 [A/G] rs6534454 4 125931345 [T/C] rs1498047 4 125933427 [T/C] rs1498046 4 125933472 [T/C] rs1498040 4 125937256 [A/G] rs1532492 4 125941623 [A/G] rs1874753 4 125946668 [A/C] rs13116115 4 125951159 [A/G] rs6851045 4 125956403 [A/G] rs6534456 4 125958645 [T/C] rs10009302 4 125960784 [A/G] rs17009085 4 125967661 [T/C] rs2647130 4 125973337 [T/C] rs1391397 4 125973565 [T/C] rs6534458 4 125976652 [T/C] rs9784420 4 125978009 [T/C] rs6822861 4 125989451 [A/G] rs12512644 4 125996360 [A/G] rs2390775 4 125998213 [T/C] rs9685753 4 126002667 [A/G] rs17791437 4 126003832 [T/C] rs2390797 4 126007059 [T/C] rs2390798 4 126007196 [A/G] rs12645899 4 126007788 [T/G] rs13124640 4 126010408 [A/G] rs4395523 4 126011991 [T/C] rs2390771 4 126013202 [A/G] rs13102452 4 126028567 [T/C] rs7675988 4 126036776 [T/C] rs3956574 4 126039335 [T/G] rs4240275 4 126053047 [T/C] rs6826117 4 126056711 [T/C] rs12506923 4 126059221 [T/C] rs13119112 4 126064719 [A/G] rs10213602 4 126066704 [A/G] rs4129246 4 126081446 [A/G] rs13136491 4 126084755 [T/C] rs17791550 4 126087650 [A/G] rs7690379 4 126093508 [A/G] rs13145439 4 126103475 [T/C] rs11098796 4 126103526 [T/C] rs12512915 4 126119697 [A/G] rs6534467 4 126122232 [T/C] rs7675694 4 126122584 [T/C] rs12499358 4 126126219 [A/G] rs7685639 4 126138152 [T/C] rs17009332 4 126144198 [T/C] rs11935229 4 126159605 [A/G] rs10518459 4 126163379 [A/G] rs7667073 4 126165609 [A/G] rs7676378 4 126169900 [T/C] rs9998852 4 126170152 [A/G] rs1039811 4 126172651 [T/C] rs1396688 4 126176069 [A/G] rs7696578 4 126182392 [T/C] rs1396696 4 126186133 [A/G] rs4571339 4 126186269 [T/G] rs1509306 4 126196021 [T/G] rs2663289 4 126198201 [A/C] rs6534472 4 126199915 [T/C] rs2663265 4 126205746 [A/G] rs2663266 4 126205766 [A/G] rs2940781 4 126208377 [T/C] rs1355167 4 126216229 [T/C] rs4834025 4 126216963 [A/G] rs11735586 4 126217989 [A/G] rs1912045 4 126219619 [A/G] rs2710572 4 126234727 [A/G] rs1039808 4 126239986 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 EXON Missense_A807V,Missense_A807V,Missense_A807V rs2940779 4 126240510 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 EXON Synonymous_L982L,Synonymous_L982L,Synonymous_L982L rs2710555 4 126241871 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 EXON Synonymous_I1435I,Synonymous_I1435I,Synonymous_I1435I rs2710534 4 126252650 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs10034706 4 126255544 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs6849785 4 126256911 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs7692092 4 126257065 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs17009473 4 126259219 [T/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs17800919 4 126261961 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs1355164 4 126262415 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs11737230 4 126267588 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs17009497 4 126267997 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs7676058 4 126270773 [T/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs2710540 4 126271899 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs9307560 4 126272004 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs11098809 4 126273052 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs2710562 4 126275373 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs17009521 4 126277208 [T/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs2710560 4 126280006 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs17193280 4 126281130 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs992122 4 126281438 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs1396686 4 126282962 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs1509284 4 126286364 [T/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs2055768 4 126289603 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs10008685 4 126291340 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs1912043 4 126305915 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs12650847 4 126306884 [A/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs1509289 4 126308835 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs1912044 4 126313149 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs7666354 4 126318368 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs11736643 4 126319772 [T/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs1509298 4 126321993 [A/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs17009641 4 126351995 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs13141820 4 126352482 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs1395233 4 126354307 [T/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs1354712 4 126359401 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs9968420 4 126364565 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs17009673 4 126366934 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs1567047 4 126372742 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 EXON Missense_G3524D,Missense_G3526D,Missense_G3526D rs17009684 4 126373653 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 EXON Missense_K3828E,Missense_K3830E,Missense_K3830E rs13128061 4 126376877 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs7696523 4 126379019 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs10518466 4 126380367 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs4146009 4 126384595 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs6813101 4 126389047 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs6828096 4 126391828 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs1506360 4 126398824 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs10026069 4 126402618 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs6824160 4 126402890 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 EXON Synonymous_V4271V,Synonymous_V4273V,Synonymous_V4273V rs17009848 4 126409835 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 Silent,Silent,Silent rs11942361 4 126411097 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 EXON Missense_E4374K,Missense_E4375K,Missense_E4376K rs1014865 4 126412332 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 EXON Synonymous_V4785V,Synonymous_V4786V,Synonymous_V4787V rs1014866 4 126412575 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 EXON Synonymous_R4866R,Synonymous_R4867R,Synonymous_R4868R rs1014867 4 126412891 [T/C] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 EXON Missense_P4972S,Missense_P4973S,Missense_P4974S rs17009858 4 126412906 [A/G] NM_024582,NM_001291285,NM_001291303 FAT4,FAT4,FAT4 EXON Missense_A4977T,Missense_A4978T,Missense_A4979T rs10031677 4 126414605 [A/G] rs4314296 4 126415914 [A/G] rs10518469 4 126419726 [A/G] rs1395227 4 126423687 [A/G] rs12639834 4 126426695 [T/C] rs950063 4 126431919 [T/C] rs1156232 4 126433214 [T/C] rs1532883 4 126434087 [A/G] rs1532881 4 126435279 [A/C] rs9986070 4 126444663 [T/C] rs1567049 4 126447482 [T/C] rs10518470 4 126447899 [A/G] rs10003468 4 126451148 [T/C] rs10518471 4 126454911 [A/G] rs7682566 4 126456647 [T/C] rs4834056 4 126456859 [T/C] rs11098817 4 126462071 [A/G] rs12500867 4 126476695 [A/G] rs6834632 4 126480268 [A/G] rs13138789 4 126482267 [T/C] rs6818629 4 126490303 [A/G] rs10016783 4 126494752 [A/G] rs1429901 4 126500482 [A/G] rs6534494 4 126504601 [T/C] rs13126049 4 126505272 [A/G] rs4507376 4 126515470 [T/C] rs1864363 4 126524825 [A/C] rs10001030 4 126535503 [A/G] rs1346715 4 126535676 [T/C] rs12331173 4 126538037 [T/G] rs6534495 4 126540305 [A/G] rs10518474 4 126553615 [T/C] rs9307573 4 126553888 [A/G] rs17820124 4 126554777 [T/C] rs6836731 4 126556868 [T/C] rs12643523 4 126561331 [A/C] rs13140903 4 126561925 [A/G] rs4834060 4 126572145 [A/C] rs34095747 4 126576950 [T/G] rs17010234 4 126593304 [T/C] rs17010235 4 126594533 [T/G] rs10434043 4 126598111 [A/G] rs17010239 4 126599698 [T/C] rs6844035 4 126603140 [T/C] rs1367066 4 126613855 [T/C] rs6831614 4 126629426 [T/G] rs10021276 4 126647502 [A/G] rs9307576 4 126654773 [T/G] rs4406033 4 126667528 [T/C] rs10018249 4 126683716 [A/G] rs4446326 4 126688743 [T/G] rs10013424 4 126694369 [A/G] rs4394015 4 126696308 [T/C] rs4591618 4 126697893 [T/C] rs7678929 4 126709492 [T/C] rs10034133 4 126709616 [T/C] rs9307578 4 126714120 [T/G] rs10440412 4 126734051 [T/G] rs6841080 4 126736372 [T/C] rs10222842 4 126741907 [T/G] rs9998979 4 126742571 [T/C] rs6854255 4 126747317 [A/G] rs4541524 4 126749816 [T/C] rs4077738 4 126749905 [T/C] rs12506206 4 126752842 [A/G] rs4590050 4 126754145 [A/G] rs11947641 4 126760793 [T/C] rs7660904 4 126761599 [T/C] rs12513118 4 126763987 [A/C] rs1911014 4 126774098 [A/G] rs17010372 4 126776121 [A/G] rs10026451 4 126779459 [A/G] rs10857108 4 126780071 [A/G] rs12645313 4 126799654 [A/G] rs4295279 4 126808558 [A/G] rs3956582 4 126808685 [T/C] rs10518477 4 126811649 [T/C] rs1506169 4 126812573 [A/G] rs2135365 4 126823576 [A/C] rs6821307 4 126832122 [A/C] rs6534520 4 126838888 [T/C] rs11721858 4 126840854 [A/C] rs962382 4 126841712 [T/C] rs1354692 4 126863195 [T/G] rs4348108 4 126864721 [T/C] rs1995604 4 126865831 [T/C] rs17224022 4 126875119 [A/G] rs12500213 4 126877070 [T/G] rs7691677 4 126880304 [T/C] rs12505759 4 126882844 [T/C] rs10019346 4 126884861 [T/C] rs13128559 4 126891842 [A/C] rs7665514 4 126892733 [A/C] rs11098847 4 126896243 [T/C] rs1506149 4 126896321 [A/C] rs12512463 4 126899057 [T/C] rs12641642 4 126902635 [A/G] rs12651652 4 126910178 [T/C] rs1021940 4 126915614 [A/C] rs17010573 4 126925575 [T/C] rs2390928 4 126931413 [A/G] rs7434822 4 126931623 [A/G] rs9993268 4 126931994 [T/G] rs10026567 4 126932102 [T/G] rs6534526 4 126937174 [T/G] rs4495049 4 126939153 [A/C] rs2893160 4 126941560 [A/G] rs34044861 4 126942485 [T/C] rs2390939 4 126943520 [A/G] rs12644234 4 126947359 [T/G] rs4834082 4 126949007 [A/G] rs2390944 4 126950447 [T/C] rs2390945 4 126950568 [A/G] rs9985873 4 126959315 [A/G] rs7656535 4 126975201 [T/C] rs4279227 4 126976466 [A/G] rs12499838 4 126976898 [T/G] rs7693642 4 126986023 [T/C] rs2271873 4 126989652 [T/C] rs2271874 4 126989724 [A/C] rs17010643 4 126991110 [T/C] rs4586960 4 127000579 [A/G] rs17010666 4 127006583 [A/C] rs9994809 4 127008222 [T/C] rs10518483 4 127009851 [A/G] rs4530647 4 127018677 [T/C] rs9686033 4 127027927 [A/G] rs11721735 4 127037075 [T/C] rs7685518 4 127041554 [A/G] rs11098856 4 127043282 [A/G] rs2062209 4 127045418 [A/G] rs13146295 4 127048641 [T/C] rs561662 4 127072596 [T/C] rs1351732 4 127077168 [T/C] rs1017863 4 127093759 [A/G] rs17010784 4 127096872 [A/G] rs2390992 4 127105360 [T/C] rs11940866 4 127105857 [T/G] rs7696522 4 127113427 [T/C] rs6838566 4 127116244 [A/G] rs4144814 4 127123816 [T/C] rs6829892 4 127134711 [T/C] rs4560423 4 127136369 [T/G] rs11931229 4 127162900 [T/C] rs17835005 4 127171396 [A/C] rs989576 4 127182592 [T/C] rs6855524 4 127196618 [A/G] rs7683349 4 127201582 [T/C] rs7666758 4 127201933 [T/C] rs1548111 4 127204248 [T/C] rs13130903 4 127207959 [A/G] rs2128782 4 127208717 [A/G] rs13132177 4 127208746 [A/G] rs10011584 4 127213903 [T/G] rs11098860 4 127220695 [T/C] rs10213170 4 127224641 [T/C] rs11725332 4 127232483 [A/G] rs1320244 4 127235715 [A/C] rs2893181 4 127242389 [A/G] rs17240023 4 127242422 [A/G] rs6852950 4 127243397 [A/G] rs17836083 4 127247924 [A/G] rs6534545 4 127249062 [T/C] rs6534548 4 127249276 [A/G] rs2391031 4 127251381 [A/G] rs11938961 4 127255447 [T/C] rs6846321 4 127256413 [T/C] rs6534549 4 127256427 [T/C] rs9991404 4 127259366 [A/G] rs6534550 4 127260284 [T/C] rs12500408 4 127264759 [T/G] rs4538495 4 127266906 [A/G] rs12509279 4 127267782 [T/C] rs1318464 4 127273449 [T/C] rs13135378 4 127281188 [T/C] rs6534554 4 127283300 [A/G] rs12508982 4 127287894 [T/G] rs13103146 4 127289047 [T/G] rs13110774 4 127290078 [A/G] rs7694254 4 127296342 [A/C] rs13124314 4 127297701 [T/C] rs7699436 4 127303936 [T/C] rs17011033 4 127309605 [A/G] rs553145 4 127309862 [T/C] rs592813 4 127313065 [T/C] rs545314 4 127313506 [T/C] rs13120906 4 127314275 [A/G] rs473695 4 127315346 [T/C] rs624738 4 127315595 [A/C] rs6812090 4 127316370 [T/C] rs12331943 4 127321888 [A/G] rs666205 4 127327343 [T/C] rs549638 4 127329737 [T/C] rs634701 4 127335358 [T/C] rs12647099 4 127336047 [A/G] rs636729 4 127337839 [T/C] rs2391054 4 127343002 [T/C] rs6534562 4 127351139 [T/C] rs1396531 4 127353144 [T/C] rs1396529 4 127354073 [T/C] rs519699 4 127360862 [T/C] rs12498806 4 127363097 [T/C] rs4833346 4 127365329 [A/G] rs484051 4 127365899 [A/G] rs1508983 4 127373021 [T/C] rs1508986 4 127374038 [T/C] rs10016992 4 127378114 [A/G] rs12499737 4 127378765 [T/C] rs12647338 4 127382084 [T/C] rs6822951 4 127399765 [A/C] rs7699051 4 127404615 [T/G] rs10032809 4 127416673 [T/G] rs7673418 4 127419470 [T/C] rs6820022 4 127429942 [T/C] rs7698081 4 127431975 [A/C] rs17011171 4 127438435 [A/G] rs1397676 4 127440009 [T/G] rs17011180 4 127440570 [T/C] rs990364 4 127440659 [T/G] rs9994335 4 127442885 [T/C] rs10006391 4 127442982 [T/C] rs1877169 4 127448140 [T/C] rs17197167 4 127450408 [T/C] rs12650680 4 127458699 [A/G] rs1543000 4 127458938 [A/G] rs992181 4 127467854 [A/G] rs17257398 4 127473539 [A/G] rs313096 4 127485146 [A/G] rs313097 4 127485170 [A/G] rs313098 4 127485630 [A/C] rs885600 4 127493571 [A/C] rs1511138 4 127516859 [T/C] rs313106 4 127518225 [T/C] rs12508410 4 127519940 [A/C] rs17258452 4 127525092 [A/G] rs7695327 4 127525235 [A/G] rs2054981 4 127529033 [A/G] rs13434700 4 127529360 [T/C] rs1511144 4 127535445 [A/G] rs7681514 4 127535865 [A/G] rs17258848 4 127536521 [T/C] rs11098887 4 127541426 [T/C] rs1511140 4 127548421 [A/C] rs447507 4 127551274 [A/G] rs17011345 4 127551516 [A/G] rs11944598 4 127552082 [A/G] rs10518503 4 127557937 [T/C] rs313045 4 127562447 [A/G] rs313040 4 127565540 [A/G] rs6534573 4 127565650 [A/C] rs170197 4 127574191 [T/C] rs386871 4 127580432 [A/G] rs313055 4 127597069 [T/C] rs398578 4 127605685 [A/C] rs12513097 4 127605711 [A/G] rs17011412 4 127607021 [A/G] rs1552665 4 127609379 [T/C] rs313071 4 127610903 [T/C] rs17011442 4 127622803 [A/G] rs313048 4 127624935 [T/C] rs7697724 4 127638432 [A/C] rs2654715 4 127644271 [T/C] rs16997921 4 127645746 [T/C] rs2969612 4 127646765 [T/C] rs6834307 4 127647807 [A/G] rs6846559 4 127649306 [A/G] rs10857117 4 127655701 [A/G] rs1167190 4 127656069 [A/G] rs1388240 4 127657442 [A/C] rs17011528 4 127660479 [A/G] rs11098892 4 127662110 [T/C] rs13121471 4 127663216 [A/G] rs13147530 4 127677784 [A/G] rs7688921 4 127700428 [T/C] rs1503626 4 127706053 [A/G] rs4834142 4 127712289 [A/G] rs12507245 4 127714708 [T/G] rs12508795 4 127720918 [T/C] rs12642632 4 127727154 [A/G] rs13130797 4 127745441 [A/G] rs6829454 4 127754030 [A/G] rs17011684 4 127767410 [T/C] rs1503609 4 127768849 [A/G] rs2134642 4 127770015 [T/C] rs4834144 4 127773649 [A/G] rs17272221 4 127774985 [T/C] rs13114412 4 127779997 [A/G] rs4270599 4 127788899 [T/C] rs1910441 4 127792639 [T/C] rs4000747 4 127794497 [A/G] rs2391097 4 127799124 [T/C] rs17011760 4 127799385 [T/C] rs4833358 4 127822133 [A/G] rs10001654 4 127822314 [A/C] rs6534591 4 127825185 [A/G] rs17011836 4 127827145 [T/G] rs1510677 4 127831937 [T/C] rs1510694 4 127862511 [T/C] rs10016117 4 127874789 [A/G] rs4834159 4 127881470 [A/C] rs17011922 4 127889513 [A/G] rs1533089 4 127892410 [T/C] rs7672986 4 127895027 [T/C] rs12510422 4 127923356 [T/C] rs4834162 4 127925448 [A/G] rs1024119 4 127964490 [T/C] rs340441 4 127973615 [A/G] rs340446 4 127977716 [T/C] rs6834065 4 127978786 [T/C] rs1383522 4 127981170 [T/C] rs17278402 4 127991638 [T/C] rs12646249 4 127992106 [A/G] rs7670859 4 127993106 [T/C] rs6852817 4 128005362 [T/C] rs1871738 4 128023339 [T/G] rs13107241 4 128046856 [T/G] rs17012111 4 128055169 [T/G] rs4385081 4 128063104 [T/C] rs1155135 4 128064562 [A/G] rs12503951 4 128072643 [A/G] rs1026824 4 128072800 [T/C] rs6837753 4 128079327 [T/C] rs1471556 4 128096615 [A/G] rs11726994 4 128097963 [T/C] rs6831679 4 128113424 [A/G] rs7683267 4 128116219 [T/G] rs1383518 4 128125715 [T/G] rs12498324 4 128132034 [T/C] rs12501497 4 128140708 [A/G] rs9307596 4 128149355 [A/G] rs4997057 4 128158126 [T/C] rs967532 4 128160430 [A/G] rs1899548 4 128167093 [T/C] rs17012285 4 128173818 [T/C] rs13122922 4 128228213 [A/G] rs995314 4 128232855 [A/G] rs6829595 4 128236361 [A/G] rs4364275 4 128242730 [T/C] rs1372965 4 128248863 [A/G] rs1838081 4 128258252 [A/G] rs1443178 4 128274696 [T/C] rs11943067 4 128283435 [A/G] rs2120087 4 128289824 [A/C] rs10428477 4 128290263 [A/G] rs13149390 4 128304199 [T/G] rs13141037 4 128313686 [A/G] rs6534619 4 128316887 [A/G] rs6833784 4 128328168 [T/C] rs1443165 4 128335450 [A/G] rs2034077 4 128337411 [A/G] rs724950 4 128342120 [T/C] rs17012433 4 128358470 [T/G] rs17012435 4 128367991 [A/G] rs7660782 4 128377396 [A/G] rs11724136 4 128391591 [T/C] rs7679411 4 128392771 [T/G] rs1443171 4 128400330 [A/G] rs2002543 4 128410916 [T/C] rs6534622 4 128411344 [A/G] rs2391184 4 128419398 [T/C] rs7696963 4 128419456 [T/C] rs1514305 4 128424502 [A/C] rs925656 4 128425000 [T/C] rs1355924 4 128427778 [T/C] rs7653949 4 128432062 [T/C] rs17012484 4 128441567 [A/C] rs1399215 4 128446769 [A/C] rs12509921 4 128454610 [A/G] rs11730901 4 128463930 [A/G] rs17012511 4 128467881 [A/G] rs12505574 4 128467975 [A/G] rs10007344 4 128474999 [T/C] rs11933223 4 128476186 [A/G] rs10005550 4 128478408 [A/G] rs1008995 4 128487450 [T/G] rs4834203 4 128488553 [A/G] rs1355925 4 128495654 [A/C] rs6534623 4 128506962 [T/G] rs1399212 4 128523964 [T/C] rs10434049 4 128528617 [A/G] rs10857124 4 128534796 [T/C] rs9942183 4 128553889 [A/G] rs2255457 4 128554404 [A/G] NM_015693 INTU Silent rs10009032 4 128555418 [A/G] NM_015693 INTU Silent rs3749507 4 128565000 [A/G] NM_015693 INTU EXON Synonymous_R157R rs6847397 4 128569904 [T/C] NM_015693 INTU Silent rs17012567 4 128604159 [T/C] NM_015693 INTU Silent rs2125573 4 128607832 [T/C] NM_015693 INTU Silent rs17012568 4 128620622 [A/G] NM_015693 INTU Silent rs17379648 4 128631859 [A/G] NM_015693 INTU Silent rs17012586 4 128651021 [A/G] rs12511932 4 128655836 [T/C] NM_031291,NM_001318467 SLC25A31,SLC25A31 Silent,Silent rs13147065 4 128668806 [A/G] NM_031291,NM_001318467 SLC25A31,SLC25A31 Silent,Silent rs11941394 4 128671177 [T/C] NM_031291,NM_001318467 SLC25A31,SLC25A31 Silent,Silent rs9995738 4 128674030 [T/C] NM_031291,NM_001318467 SLC25A31,SLC25A31 Silent,Silent rs11933454 4 128684607 [A/G] NM_031291,NM_001318467 SLC25A31,SLC25A31 Silent,Silent rs35467680 4 128688220 [T/G] NM_031291,NM_001318467 SLC25A31,SLC25A31 Silent,Silent rs2305958 4 128689936 [A/G] NM_031291,NM_001318467 SLC25A31,SLC25A31 EXON Synonymous_P221P,Synonymous_P221P rs4833391 4 128694288 [T/G] NM_031291,NM_001318467 SLC25A31,SLC25A31 Silent,Silent rs11098937 4 128697519 [T/C] rs11946033 4 128711427 [T/G] NM_001317381,NM_014278,NM_001317383,NM_001317382 HSPA4L,HSPA4L,HSPA4L,HSPA4L Silent,Silent,Silent,Silent rs9992298 4 128715609 [A/C] NM_001317381,NM_014278,NM_001317383,NM_001317382 HSPA4L,HSPA4L,HSPA4L,HSPA4L Silent,Silent,Silent,Silent rs2061442 4 128716083 [A/G] NM_001317381,NM_014278,NM_001317383,NM_001317382 HSPA4L,HSPA4L,HSPA4L,HSPA4L Silent,Silent,Silent,Silent rs1380154 4 128723042 [T/C] NM_001317381,NM_014278,NM_001317383,NM_001317382 HSPA4L,HSPA4L,HSPA4L,HSPA4L EXON Missense_L242S,Missense_L211S,Missense_L170S,Missense_L185S rs17012662 4 128723458 [T/G] NM_001317381,NM_014278,NM_001317383,NM_001317382 HSPA4L,HSPA4L,HSPA4L,HSPA4L Silent,Silent,Silent,Silent rs2305957 4 128732926 [A/G] NM_001317381,NM_014278,NM_001317383,NM_001317382 HSPA4L,HSPA4L,HSPA4L,HSPA4L Silent,Silent,Silent,Silent rs35518193 4 128741710 [T/C] NM_001317381,NM_014278,NM_001317383,NM_001317382 HSPA4L,HSPA4L,HSPA4L,HSPA4L EXON Missense_I632T,Missense_I601T,Missense_I560T,Missense_I575T rs17012695 4 128750948 [A/G] NM_001317381,NM_014278,NM_001317383,NM_001317382 HSPA4L,HSPA4L,HSPA4L,HSPA4L Silent,Silent,Silent,Silent rs11934062 4 128751804 [T/C] NM_001317381,NM_014278,NM_001317383,NM_001317382 HSPA4L,HSPA4L,HSPA4L,HSPA4L EXON Synonymous_Y757Y,Synonymous_Y726Y,Synonymous_Y685Y,Synonymous_Y700Y rs17314566 4 128761940 [A/G] rs1824331 4 128766074 [T/C] rs11723501 4 128801822 [A/C] rs3811741 4 128803159 [A/G] NM_014264,NM_001190799,NM_001190801 PLK4,PLK4,PLK4 Silent,Silent,Silent rs16997978 4 128809774 [A/G] NM_014264,NM_001190799,NM_001190801 PLK4,PLK4,PLK4 Silent,Silent,Silent rs17012739 4 128814964 [T/G] NM_014264,NM_001190799,NM_001190801 PLK4,PLK4,PLK4 EXON Missense_E830D,Missense_E798D,Missense_E789D rs17012750 4 128817558 [A/G] NM_014264,NM_001190799,NM_001190801 PLK4,PLK4,PLK4 Silent,Silent,Silent rs12503257 4 128832078 [T/C] rs11938181 4 128839380 [T/C] NM_152778,NM_001363520,NM_001363521 MFSD8,MFSD8,MFSD8 EXON Silent,Silent,Silent rs11940642 4 128841252 [T/C] NM_152778,NM_001363520,NM_001363521 MFSD8,MFSD8,MFSD8 EXON Silent,Silent,Silent rs3733319 4 128842761 [A/G] NM_152778,NM_001363520,NM_001363521 MFSD8,MFSD8,MFSD8 EXON Missense_A423V,Missense_A356V,Missense_A318V rs1602084 4 128843480 [A/G] NM_152778,NM_001363520,NM_001363521 MFSD8,MFSD8,MFSD8 Silent,Silent,Silent rs17393302 4 128866916 [T/C] NM_152778,NM_001363520,NM_001363521 MFSD8,MFSD8,MFSD8 Silent,Silent,Silent rs17012804 4 128867612 [T/C] NM_152778,NM_001363520,NM_001363521 MFSD8,MFSD8,MFSD8 Silent,Silent,Silent rs2276900 4 128886578 [T/C] NM_152778,NM_001358454,NM_001319305,NM_001319306,NM_001319307,NM_001358451 MFSD8,ABHD18,ABHD18,ABHD18,ABHD18,ABHD18 EXON Silent,Silent,Silent,Silent,Silent,Silent rs748630 4 128901402 [A/G] NM_001358454,NM_001319305,NM_001319306,NM_001319307,NM_001358451 ABHD18,ABHD18,ABHD18,ABHD18,ABHD18 Silent,Silent,Silent,Silent,Silent rs12645636 4 128906553 [T/C] NM_001358454,NM_001319305,NM_001319306,NM_001319307,NM_001358451 ABHD18,ABHD18,ABHD18,ABHD18,ABHD18 Silent,Silent,Silent,Silent,Silent rs11935267 4 128907305 [T/C] NM_001358454,NM_001319305,NM_001319306,NM_001319307,NM_001358451 ABHD18,ABHD18,ABHD18,ABHD18,ABHD18 Silent,Silent,Silent,Silent,Silent rs17012845 4 128914544 [T/C] NM_001358454,NM_001319305,NM_001319306,NM_001319307,NM_001358451 ABHD18,ABHD18,ABHD18,ABHD18,ABHD18 Silent,Silent,Silent,Silent,Silent rs10028090 4 128919924 [T/G] NM_001358454,NM_001319305,NM_001319306,NM_001319307,NM_001358451 ABHD18,ABHD18,ABHD18,ABHD18,ABHD18 Silent,Silent,Silent,Silent,Silent rs28674488 4 128923006 [T/G] NM_001358454,NM_001319305,NM_001319306,NM_001319307,NM_001358451 ABHD18,ABHD18,ABHD18,ABHD18,ABHD18 Silent,Silent,Silent,Silent,Silent rs28687198 4 128940313 [A/G] NM_001358454,NM_001319305,NM_001319306,NM_001319307,NM_001358451 ABHD18,ABHD18,ABHD18,ABHD18,ABHD18 Silent,Silent,Silent,Silent,Silent rs17012870 4 128944317 [A/G] NM_001358454,NM_001319305,NM_001319306,NM_001319307,NM_001358451 ABHD18,ABHD18,ABHD18,ABHD18,ABHD18 Silent,Silent,Silent,Silent,Silent rs17315466 4 128954647 [T/C] NM_001358454,NM_001319305,NM_001319306,NM_001319307,NM_001358451 ABHD18,ABHD18,ABHD18,ABHD18,ABHD18 Silent,Silent,Silent,Silent,Silent rs11098945 4 128960569 [T/C] NM_001358454,NM_001319305,NM_001319306,NM_001319307,NM_001358451 ABHD18,ABHD18,ABHD18,ABHD18,ABHD18 EXON Silent,Silent,Silent,Silent,Silent rs4834224 4 128981336 [A/G] rs4834226 4 128986874 [T/C] NM_032239,NR_146772,NM_018078,NM_178043,NM_001278604,NM_001350531 LARP1B,LARP1B,LARP1B,LARP1B,LARP1B,LARP1B Silent,Silent,Silent,Silent,Silent,Silent rs2306054 4 129012181 [A/G] NM_032239,NR_146772,NM_018078,NM_178043,NM_001278604,NM_001350531 LARP1B,LARP1B,LARP1B,LARP1B,LARP1B,LARP1B EXON Synonymous_R128R,Silent,Synonymous_R128R,Synonymous_R128R,Synonymous_R128R,Silent rs4834232 4 129024273 [T/C] NM_032239,NR_146772,NM_018078,NM_178043,NM_001278604,NM_001350531 LARP1B,LARP1B,LARP1B,LARP1B,LARP1B,LARP1B Silent,Silent,Silent,Silent,Silent,Silent rs10049564 4 129029653 [A/G] NM_032239,NR_146772,NM_018078,NM_178043,NM_001278604,NM_001350531 LARP1B,LARP1B,LARP1B,LARP1B,LARP1B,LARP1B EXON Silent,Silent,Silent,Silent,Silent,Silent rs10857129 4 129045317 [A/G] NR_146772,NM_018078,NM_001350531 LARP1B,LARP1B,LARP1B Silent,Silent,Silent rs4417984 4 129047870 [A/G] NR_146772,NM_018078,NM_001350531 LARP1B,LARP1B,LARP1B Silent,Silent,Silent rs2061571 4 129052429 [T/C] NR_146772,NM_018078,NM_001350531 LARP1B,LARP1B,LARP1B Silent,Silent,Silent rs17012954 4 129062609 [T/C] NR_146772,NM_018078,NM_001350531 LARP1B,LARP1B,LARP1B Silent,Silent,Silent rs10000748 4 129082491 [T/C] NR_146772,NM_018078,NM_001350531 LARP1B,LARP1B,LARP1B Silent,Silent,Silent rs12645577 4 129100643 [A/G] NR_146772,NM_018078,NM_001350531 LARP1B,LARP1B,LARP1B EXON Silent,Missense_R660H,Missense_R380H rs2172813 4 129104537 [A/G] NR_146772,NM_018078,NM_001350531 LARP1B,LARP1B,LARP1B Silent,Silent,Silent rs6856312 4 129113495 [A/G] NR_146772,NM_018078,NM_001350531 LARP1B,LARP1B,LARP1B Silent,Silent,Silent rs6534672 4 129142079 [T/C] NR_146772 LARP1B Silent rs12510308 4 129149880 [T/G] rs4975300 4 129160316 [T/C] rs4975200 4 129176047 [T/C] rs13133067 4 129180759 [T/C] rs11726595 4 129189040 [T/C] rs17013071 4 129189567 [T/C] rs3755897 4 129196191 [T/C] NM_006320 PGRMC2 Silent rs11947006 4 129203676 [T/C] NM_006320 PGRMC2 Silent rs4975221 4 129213745 [T/C] rs11943040 4 129214377 [A/G] rs6845290 4 129217267 [A/G] rs1391980 4 129218126 [T/C] rs6534677 4 129221901 [T/C] rs10001857 4 129223349 [T/C] rs10001690 4 129232129 [A/G] rs10019366 4 129239583 [T/G] rs11098956 4 129244451 [A/G] rs4975181 4 129247395 [A/G] rs17337491 4 129254598 [A/G] rs290003 4 129261079 [T/C] rs11723210 4 129281445 [T/C] rs17013164 4 129281866 [A/G] rs1982904 4 129282956 [T/G] rs7655151 4 129296922 [A/G] rs7695173 4 129303169 [A/G] rs17013235 4 129307260 [T/C] rs3853107 4 129309601 [T/C] rs3870129 4 129311823 [T/C] rs17013261 4 129314562 [T/C] rs10022598 4 129314791 [T/C] rs10020014 4 129314887 [T/C] rs11098961 4 129315804 [T/C] rs17013269 4 129336928 [A/G] rs12508336 4 129345343 [T/C] rs11098966 4 129346970 [T/C] rs10021346 4 129349449 [A/G] NR_125882 LOC100507487 EXON Silent rs4305531 4 129369697 [T/C] NR_125882 LOC100507487 Silent rs11728419 4 129370768 [A/G] NR_125882 LOC100507487 Silent rs6850541 4 129373016 [A/G] NR_125882 LOC100507487 Silent rs17013315 4 129373425 [T/C] NR_125882 LOC100507487 Silent rs9307607 4 129375881 [T/C] NR_125882 LOC100507487 Silent rs4498144 4 129380839 [T/C] NR_125882 LOC100507487 Silent rs6534682 4 129382079 [T/G] NR_125882 LOC100507487 Silent rs6534683 4 129382308 [T/C] NR_125882 LOC100507487 Silent rs17013332 4 129382634 [A/G] NR_125882 LOC100507487 Silent rs6840580 4 129389738 [A/G] NR_125882 LOC100507487 Silent rs10000490 4 129392060 [A/G] NR_125882 LOC100507487 Silent rs10012794 4 129401741 [A/C] NR_125882 LOC100507487 Silent rs7690289 4 129409513 [T/C] NR_125882 LOC100507487 Silent rs13134269 4 129412788 [T/C] NR_125882 LOC100507487 Silent rs17013357 4 129414681 [T/C] NR_125882 LOC100507487 Silent rs4549394 4 129431298 [T/C] NR_125882 LOC100507487 Silent rs7441245 4 129436625 [A/G] NR_125882 LOC100507487 Silent rs6821705 4 129439313 [A/C] NR_125882 LOC100507487 Silent rs6534689 4 129441798 [A/G] rs6843137 4 129442692 [A/C] rs4975234 4 129445452 [A/G] rs7695069 4 129445759 [T/C] rs4975235 4 129447957 [T/G] rs1603886 4 129450677 [T/C] rs10518533 4 129458258 [T/G] rs6835518 4 129462245 [T/C] rs1032673 4 129465489 [A/C] rs7678706 4 129471494 [A/G] rs2173502 4 129472039 [T/C] rs9991179 4 129477404 [A/G] rs12510203 4 129477529 [T/C] rs12644043 4 129482193 [A/G] rs6858471 4 129483230 [T/C] rs2036237 4 129483448 [T/C] rs17013477 4 129489592 [A/G] rs17013481 4 129494050 [T/C] rs17013484 4 129495183 [A/G] rs17013486 4 129495243 [T/C] rs1216378 4 129499923 [T/C] rs1216383 4 129503678 [T/C] rs1216394 4 129509265 [T/C] rs10518534 4 129526565 [A/G] rs1216405 4 129527656 [T/C] rs1216411 4 129529446 [A/G] rs1216412 4 129529604 [A/G] rs1216416 4 129531333 [A/G] rs10446738 4 129540702 [A/G] rs1216440 4 129543559 [A/G] rs1216348 4 129557924 [T/C] rs7670660 4 129558393 [A/G] rs1615523 4 129568096 [T/C] rs10518535 4 129574474 [A/C] rs17013522 4 129574927 [T/C] rs2391291 4 129581554 [T/C] rs16998005 4 129582685 [A/G] rs11098979 4 129585163 [T/C] rs1553142 4 129587449 [A/G] rs1553143 4 129587598 [T/C] rs17013577 4 129589411 [A/G] rs12505241 4 129589784 [A/G] rs17013593 4 129593111 [A/G] rs7700079 4 129598078 [A/G] rs6856260 4 129611736 [T/C] rs12512245 4 129611773 [A/G] rs6837389 4 129612729 [T/C] rs10024708 4 129639124 [A/G] rs13147397 4 129646870 [T/C] rs6534699 4 129651071 [T/C] rs1425619 4 129654251 [A/G] rs933826 4 129654459 [A/G] rs6820206 4 129675024 [T/G] rs4975249 4 129676063 [A/G] rs2033052 4 129676284 [T/C] rs17013657 4 129679066 [T/C] rs4435757 4 129682775 [T/C] rs11941279 4 129692038 [A/G] rs17013678 4 129694008 [A/G] rs4975253 4 129694554 [T/C] rs10017881 4 129696911 [T/C] rs1863337 4 129698469 [T/C] rs11098986 4 129700043 [A/G] rs4975260 4 129708024 [A/G] rs13101730 4 129709109 [T/C] rs6813608 4 129709244 [A/G] rs9991981 4 129713511 [A/G] rs1031691 4 129721687 [T/C] rs13143771 4 129729412 [T/C] rs10017436 4 129737089 [A/G] NM_001287437,NM_199320,NM_024900,NM_001287440,NM_001287439,NM_001287442,NM_001287441,NM_001287443 JADE1,JADE1,JADE1,JADE1,JADE1,JADE1,JADE1,JADE1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17346077 4 129740590 [A/G] NM_001287437,NM_199320,NM_024900,NM_001287440,NM_001287439,NM_001287442,NM_001287441,NM_001287443 JADE1,JADE1,JADE1,JADE1,JADE1,JADE1,JADE1,JADE1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17013734 4 129746735 [T/C] NM_001287437,NM_199320,NM_024900,NM_001287440,NM_001287439,NM_001287442,NM_001287441,NM_001287443 JADE1,JADE1,JADE1,JADE1,JADE1,JADE1,JADE1,JADE1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4975270 4 129757215 [A/G] NM_001287437,NM_199320,NM_024900,NM_001287440,NM_001287439,NM_001287442,NM_001287441,NM_001287443 JADE1,JADE1,JADE1,JADE1,JADE1,JADE1,JADE1,JADE1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6847753 4 129774375 [A/G] NM_001287437,NM_199320,NM_024900,NM_001287440,NM_001287439,NM_001287442,NM_001287441,NM_001287443 JADE1,JADE1,JADE1,JADE1,JADE1,JADE1,JADE1,JADE1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17013835 4 129778510 [A/G] NM_001287437,NM_199320,NM_024900,NM_001287440,NM_001287439,NM_001287442,NM_001287441,NM_001287443 JADE1,JADE1,JADE1,JADE1,JADE1,JADE1,JADE1,JADE1 EXON Synonymous_P282P,Synonymous_P294P,Synonymous_P294P,Synonymous_P294P,Synonymous_P294P,Synonymous_P294P,Synonymous_P294P,Synonymous_P294P rs2162126 4 129779076 [T/C] NM_001287437,NM_199320,NM_024900,NM_001287440,NM_001287439,NM_001287442,NM_001287441,NM_001287443 JADE1,JADE1,JADE1,JADE1,JADE1,JADE1,JADE1,JADE1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11933240 4 129793559 [A/G] NM_001287437,NM_199320,NM_001287440,NM_001287439,NM_001287442,NM_001287443 JADE1,JADE1,JADE1,JADE1,JADE1,JADE1 EXON Silent,Silent,Silent,Silent,Silent,Silent rs9991702 4 129796506 [A/C] rs11940298 4 129803970 [A/G] rs186444 4 129825629 [A/G] NM_144643 SCLT1 Silent rs318543 4 129836255 [T/C] NM_144643 SCLT1 Silent rs318549 4 129838879 [T/C] NM_144643 SCLT1 Silent rs11722253 4 129840234 [T/C] NM_144643 SCLT1 Silent rs6840353 4 129860963 [T/C] NM_144643 SCLT1 Silent rs2034497 4 129862073 [T/C] NM_144643 SCLT1 Silent rs7682145 4 129866452 [T/G] NM_144643 SCLT1 Silent rs10028124 4 129867280 [A/T] NM_144643 SCLT1 EXON Missense_S441C rs13139306 4 129871531 [A/G] NM_144643 SCLT1 Silent rs4975288 4 129873147 [T/C] NM_144643 SCLT1 Silent rs13136209 4 129876270 [A/C] NM_144643 SCLT1 Silent rs921377 4 129879744 [A/G] NM_144643 SCLT1 Silent rs17013994 4 129898391 [T/C] NM_144643 SCLT1 Silent rs13151322 4 129913345 [A/G] NM_144643 SCLT1 EXON Synonymous_I221I rs280601 4 129914268 [T/C] NM_144643 SCLT1 Silent rs3113487 4 129924977 [A/C] NM_144643 SCLT1 EXON Synonymous_L115L rs2044523 4 129927804 [T/C] NM_144643 SCLT1 Silent rs789982 4 129999071 [T/C] NM_144643,NM_001300898,NM_001300897 SCLT1,SCLT1,SCLT1 Silent,Silent,Silent rs1699388 4 130003237 [T/C] NM_144643,NM_001300898,NM_001300897 SCLT1,SCLT1,SCLT1 Silent,Silent,Silent rs11728895 4 130013447 [A/G] NM_144643,NM_001300898,NM_001300897 SCLT1,SCLT1,SCLT1 Silent,Silent,Silent rs13136220 4 130019889 [T/C] NM_173487,NM_001099783 C4orf33,C4orf33 Silent,Silent rs1030831 4 130025037 [T/G] NM_173487,NM_001099783 C4orf33,C4orf33 Silent,Silent rs1030830 4 130025117 [T/C] NM_173487,NM_001099783 C4orf33,C4orf33 Silent,Silent rs2271570 4 130030644 [T/C] NM_173487,NM_001099783 C4orf33,C4orf33 EXON Missense_S104L,Missense_S104L rs337277 4 130030652 [A/G] NM_173487,NM_001099783 C4orf33,C4orf33 EXON Missense_M107V,Missense_M107V rs337276 4 130030944 [A/C] NM_173487,NM_001099783 C4orf33,C4orf33 Silent,Silent rs1867951 4 130032119 [A/C] NM_173487,NM_001099783 C4orf33,C4orf33 Silent,Silent rs337270 4 130042232 [A/C] rs337268 4 130043321 [T/C] rs12500557 4 130051748 [A/G] rs234264 4 130056276 [T/C] rs1827605 4 130056516 [A/G] rs17014243 4 130057766 [T/C] rs1849762 4 130058367 [A/G] rs1757923 4 130058670 [T/C] rs11946237 4 130060230 [A/G] rs4616770 4 130072652 [T/C] rs13123966 4 130074947 [A/G] rs11099001 4 130077663 [T/C] rs13132155 4 130083679 [T/C] rs11726808 4 130089052 [T/C] rs11735242 4 130089540 [A/G] rs1113473 4 130093303 [T/G] rs2037073 4 130095095 [T/C] rs17790511 4 130096106 [T/C] rs12511477 4 130112548 [T/C] rs10518545 4 130114848 [A/G] rs10857138 4 130121328 [A/G] rs6857889 4 130122117 [A/G] rs7659741 4 130123251 [A/G] rs488685 4 130130312 [A/G] rs512552 4 130130625 [A/C] rs17014455 4 130130914 [A/G] rs477926 4 130133372 [T/C] rs7675783 4 130136452 [T/C] rs908103 4 130136648 [T/C] rs908102 4 130137058 [T/G] rs6854308 4 130139735 [T/C] rs1699376 4 130140333 [A/G] rs1875799 4 130141681 [A/C] rs9990850 4 130144491 [T/C] rs1757939 4 130146176 [T/C] rs971446 4 130155315 [T/C] rs6842443 4 130155588 [A/G] rs7682166 4 130158317 [T/C] rs1514572 4 130160706 [A/C] rs1355962 4 130160851 [T/C] rs1514570 4 130161004 [T/C] rs11938065 4 130161321 [T/C] rs7677291 4 130161349 [T/C] rs17014505 4 130163564 [T/C] rs17432813 4 130163823 [T/G] rs17367253 4 130167235 [T/C] rs11099004 4 130167642 [A/G] rs6824516 4 130171981 [T/C] rs6829641 4 130178102 [T/C] rs6534714 4 130184243 [T/C] rs9994767 4 130185974 [T/C] rs4132289 4 130187875 [T/C] rs9917851 4 130192103 [A/G] rs13119203 4 130194362 [A/G] rs4604070 4 130196647 [A/G] rs4484315 4 130200129 [T/C] rs4975208 4 130200748 [A/C] rs6825050 4 130205744 [A/G] rs4426799 4 130216263 [A/G] rs6849054 4 130221251 [T/G] rs10857139 4 130222259 [T/C] rs4355401 4 130230383 [A/C] rs6856123 4 130236239 [T/C] rs4334769 4 130245233 [T/G] rs6813691 4 130245888 [T/C] rs9994470 4 130247519 [T/G] rs11099007 4 130260879 [A/G] rs10031400 4 130264384 [T/G] rs4975217 4 130267046 [T/G] rs4975218 4 130267085 [A/G] rs17014612 4 130267509 [T/C] rs6820523 4 130277165 [A/G] rs11942553 4 130300709 [A/G] rs10014575 4 130308015 [T/G] rs4246726 4 130308804 [T/G] rs11933154 4 130310751 [A/G] rs4376156 4 130314764 [T/C] rs11942882 4 130315957 [A/G] rs1433378 4 130316519 [T/C] rs6845051 4 130317282 [T/G] rs13139447 4 130318033 [T/G] rs1030696 4 130318128 [A/G] rs9654209 4 130318728 [A/G] rs10020025 4 130322579 [A/G] rs10001834 4 130325201 [T/G] rs9996475 4 130327194 [A/G] rs17014740 4 130328109 [A/C] rs6837783 4 130332644 [A/G] rs2043372 4 130333958 [T/C] rs1433375 4 130338059 [T/C] rs11730148 4 130338172 [A/C] rs17014760 4 130340880 [A/G] rs17014762 4 130341403 [A/G] rs1816429 4 130347005 [T/C] rs995638 4 130364131 [A/G] rs995637 4 130364383 [A/G] rs13125482 4 130367473 [T/C] rs1865178 4 130373727 [A/G] rs1433384 4 130375150 [T/C] rs1865176 4 130375622 [T/C] rs12648468 4 130376388 [A/C] rs17370136 4 130378087 [A/G] rs621740 4 130378616 [T/C] rs623865 4 130384715 [T/C] rs7666727 4 130390365 [A/G] rs592988 4 130396639 [T/C] rs3097948 4 130403749 [A/G] rs4527497 4 130410990 [A/G] rs17050480 4 130412286 [T/C] rs17050482 4 130412508 [A/G] rs650483 4 130417557 [T/C] rs600121 4 130421169 [A/G] rs650052 4 130439039 [T/C] rs724156 4 130444832 [A/G] rs685845 4 130450256 [A/G] rs666306 4 130453157 [A/G] rs582743 4 130455765 [T/G] rs659322 4 130458147 [T/C] rs1074762 4 130464486 [T/C] rs17372420 4 130469784 [T/G] rs10857140 4 130474564 [A/G] rs1517066 4 130476563 [T/C] rs13123291 4 130476685 [A/C] rs1356342 4 130482494 [T/C] rs11725348 4 130508349 [T/C] rs628527 4 130523279 [A/G] rs12649182 4 130530633 [T/C] rs3106876 4 130535115 [T/C] rs10518552 4 130536283 [T/C] rs6849510 4 130539982 [A/G] rs17439675 4 130543768 [T/C] rs10001198 4 130547353 [A/G] rs10017568 4 130552827 [A/G] rs2035794 4 130555339 [A/C] rs7674283 4 130562576 [A/G] rs17050583 4 130568677 [T/G] rs9307614 4 130569024 [T/C] rs1907454 4 130580317 [A/G] rs7699448 4 130588996 [A/G] rs11931950 4 130591851 [T/G] rs17050588 4 130592857 [T/G] rs2728765 4 130593382 [A/C] rs2637618 4 130597120 [A/G] rs2728740 4 130601796 [T/C] rs4864109 4 130606797 [A/G] rs2728760 4 130619114 [A/G] rs2637613 4 130626785 [A/G] rs13115271 4 130645957 [T/C] NR_110753 LINC02466 EXON Silent rs2728752 4 130646527 [A/G] NR_110753 LINC02466 EXON Silent rs2728748 4 130650949 [T/C] NR_110753 LINC02466 Silent rs10022354 4 130654405 [T/C] NR_110753 LINC02466 Silent rs10020857 4 130655673 [T/C] NR_110753 LINC02466 Silent rs10011452 4 130655964 [T/C] NR_110753 LINC02466 Silent rs2637592 4 130656378 [A/G] NR_110753 LINC02466 Silent rs2728743 4 130658868 [T/C] NR_110753 LINC02466 Silent rs11726911 4 130661821 [A/C] NR_110753 LINC02466 Silent rs2035793 4 130664077 [A/G] NR_110753 LINC02466 Silent rs6827640 4 130667787 [A/G] NR_110753 LINC02466 Silent rs13126098 4 130672736 [A/G] NR_110753 LINC02466 Silent rs961410 4 130678673 [T/C] NR_110753 LINC02466 Silent rs2391481 4 130680257 [A/G] NR_110753 LINC02466 Silent rs4608819 4 130680689 [T/C] NR_110753 LINC02466 Silent rs10010057 4 130680706 [T/G] NR_110753 LINC02466 Silent rs17050638 4 130681587 [T/C] NR_110753 LINC02466 Silent rs4417988 4 130684221 [T/G] NR_110753 LINC02466 Silent rs10518556 4 130691794 [A/G] NR_110753 LINC02466 Silent rs1962347 4 130692145 [T/C] NR_110753 LINC02466 Silent rs4317218 4 130696787 [T/C] NR_151713 LINC02465 Silent rs2391560 4 130701197 [A/C] NR_151713 LINC02465 EXON Silent rs17690833 4 130707281 [T/C] NR_151713 LINC02465 Silent rs7692863 4 130707396 [T/C] NR_151713 LINC02465 Silent rs11099019 4 130710218 [A/G] NR_151713 LINC02465 Silent rs6534743 4 130714768 [A/G] NR_151713 LINC02465 Silent rs17050657 4 130718292 [A/G] NR_151713 LINC02465 Silent rs11099020 4 130724902 [T/C] NR_151713 LINC02465 Silent rs2391504 4 130731072 [A/G] NR_151713 LINC02465 Silent rs2955478 4 130738875 [A/G] NR_151713 LINC02465 Silent rs6836368 4 130751286 [A/G] NR_151713 LINC02465 Silent rs7698306 4 130754209 [A/G] NR_151713 LINC02465 Silent rs2391535 4 130756174 [T/C] NR_151713 LINC02465 Silent rs12233773 4 130756415 [T/C] NR_151713 LINC02465 Silent rs11931514 4 130758675 [A/G] NR_151713 LINC02465 Silent rs2952862 4 130758713 [T/C] NR_151713 LINC02465 Silent rs2860199 4 130764605 [T/C] NR_151713 LINC02465 Silent rs10022903 4 130765713 [T/C] NR_151713 LINC02465 Silent rs10028795 4 130767230 [A/G] NR_151713 LINC02465 Silent rs4863907 4 130767559 [A/C] NR_151713 LINC02465 Silent rs17050689 4 130767899 [T/C] NR_151713 LINC02465 Silent rs2968999 4 130784545 [A/G] NR_151713 LINC02465 Silent rs3111741 4 130824678 [A/G] NR_151713 LINC02465 Silent rs2968959 4 130827136 [T/G] NR_151713 LINC02465 Silent rs4447877 4 130827478 [A/G] NR_151713 LINC02465 Silent rs17050730 4 130830614 [A/G] NR_151713 LINC02465 Silent rs2952871 4 130839795 [T/C] NR_151713 LINC02465 Silent rs17050751 4 130849076 [A/G] NR_151713 LINC02465 Silent rs12644225 4 130850180 [A/G] NR_151713 LINC02465 Silent rs2968955 4 130857829 [A/G] NR_151713 LINC02465 Silent rs10025344 4 130866817 [A/G] NR_151713 LINC02465 Silent rs17050760 4 130869806 [A/G] NR_151713 LINC02465 Silent rs6847497 4 130876131 [T/C] NR_151713 LINC02465 Silent rs6825946 4 130876818 [T/C] rs10013838 4 130882146 [T/G] rs1995720 4 130887651 [A/G] rs17050768 4 130889648 [T/G] rs17388944 4 130892616 [A/G] rs17455138 4 130903511 [T/C] rs2391577 4 130912560 [T/G] rs2940273 4 130913879 [T/C] rs2940288 4 130918048 [T/G] rs1567192 4 130928325 [T/C] rs17050809 4 130948872 [T/C] rs7661528 4 130949366 [A/G] rs11099027 4 130952981 [T/C] rs2135927 4 130956277 [T/C] rs1567193 4 130962263 [T/C] rs7665451 4 130962301 [T/C] rs6534761 4 130965930 [A/G] rs1022009 4 130966165 [T/C] rs1022005 4 130966863 [A/C] rs6534762 4 130978989 [A/G] rs4864311 4 130980955 [T/C] rs6844491 4 130983055 [A/G] rs12499245 4 130983605 [A/G] rs4863950 4 130984088 [A/G] rs10017257 4 130985136 [T/C] rs17050831 4 130985845 [A/G] rs1507776 4 130994157 [T/C] rs13134698 4 130997758 [T/G] rs10022994 4 131003046 [A/G] rs11934226 4 131003605 [A/G] rs11933661 4 131013140 [T/C] rs1507787 4 131016112 [T/C] rs6827509 4 131017136 [T/G] rs2391598 4 131018271 [T/C] rs11099035 4 131021262 [A/G] rs17405853 4 131030874 [A/G] rs17050842 4 131034819 [T/G] rs2391603 4 131061059 [A/C] rs13109471 4 131062487 [T/C] rs1493226 4 131062875 [A/C] rs6853869 4 131063868 [T/C] rs10011007 4 131064690 [A/C] rs1845224 4 131071699 [T/C] rs17050863 4 131083338 [A/G] rs17050864 4 131085096 [A/G] rs17472783 4 131090084 [T/C] rs7656732 4 131091376 [T/C] rs6826948 4 131093532 [A/G] rs6827503 4 131093554 [A/G] rs17050872 4 131097748 [A/C] rs10003688 4 131097850 [A/G] rs17407415 4 131100838 [A/G] rs13107934 4 131101141 [A/G] rs17050881 4 131103736 [T/C] rs13106127 4 131104359 [T/C] rs1979689 4 131107527 [A/G] rs1979690 4 131107545 [A/G] rs2893315 4 131108390 [T/C] rs2220754 4 131109747 [T/C] rs10034121 4 131109983 [T/G] rs6837104 4 131110436 [T/C] rs1873867 4 131116188 [T/C] rs1120962 4 131116943 [A/G] rs7690486 4 131117354 [A/C] rs1602816 4 131118067 [T/C] rs2391607 4 131118613 [A/G] rs10001806 4 131119614 [T/G] rs12504035 4 131121249 [A/G] rs13149325 4 131122852 [A/G] rs6819699 4 131125809 [T/C] rs17408481 4 131127703 [T/G] rs11099040 4 131131416 [T/C] rs17050901 4 131132532 [A/G] rs13113376 4 131132900 [T/C] rs1024020 4 131137761 [T/C] rs4449432 4 131167056 [T/C] rs7437554 4 131169265 [A/G] rs12506063 4 131174088 [T/C] rs11099042 4 131174498 [A/G] rs6833836 4 131175071 [A/G] rs4383635 4 131194571 [A/G] rs11944858 4 131198147 [T/C] rs10518570 4 131200309 [T/G] rs4864426 4 131201900 [T/C] rs7697995 4 131202954 [A/G] rs17050940 4 131206901 [T/C] rs10024383 4 131207582 [A/G] rs1027885 4 131212589 [A/C] rs1033018 4 131215475 [A/G] rs1022079 4 131238094 [A/C] rs9307624 4 131242185 [A/G] rs9307625 4 131242827 [A/G] rs17050958 4 131243869 [A/G] rs7662168 4 131250760 [A/G] rs10032131 4 131252392 [A/G] rs6815723 4 131253096 [T/C] rs6838581 4 131253173 [T/C] rs6838871 4 131253435 [A/G] rs7688496 4 131254621 [T/C] rs1396766 4 131263678 [A/G] rs13143102 4 131264117 [A/G] rs9307626 4 131265231 [A/G] rs6827936 4 131269444 [A/G] rs2310878 4 131272587 [A/G] rs17050983 4 131280307 [T/G] rs1912101 4 131282678 [T/G] rs1509446 4 131282886 [A/C] rs16998043 4 131286529 [T/C] rs11737037 4 131290993 [T/G] rs1581037 4 131296975 [T/C] rs12509540 4 131297208 [A/G] rs11099049 4 131297577 [A/G] NR_147186 LINC02479 EXON Silent rs4458467 4 131297764 [A/C] NR_147186 LINC02479 Silent rs10033555 4 131300750 [T/G] NR_147186 LINC02479 Silent rs1396757 4 131301036 [T/C] NR_147186 LINC02479 Silent rs6534789 4 131304008 [A/G] NR_147186 LINC02479 Silent rs11931985 4 131309152 [T/C] NR_147186 LINC02479 EXON Silent rs11099051 4 131311267 [T/G] rs12331990 4 131314946 [A/C] rs4863988 4 131322432 [A/C] rs1396763 4 131339908 [A/C] rs7675553 4 131340652 [A/G] rs1355187 4 131342779 [A/G] rs7657931 4 131353634 [T/C] rs4863816 4 131354219 [T/C] rs7665833 4 131381117 [A/G] rs10026321 4 131389611 [T/C] rs10020348 4 131390997 [A/G] rs6813929 4 131392589 [A/G] rs10001417 4 131392651 [A/G] rs6853908 4 131415182 [T/G] rs2926419 4 131417196 [T/C] rs17051032 4 131419288 [A/G] rs2871891 4 131431602 [T/G] rs6817368 4 131438739 [T/C] rs2926412 4 131438987 [T/C] rs7664079 4 131451250 [A/G] rs12502992 4 131451365 [A/G] rs7677917 4 131453828 [A/G] rs2969152 4 131456285 [A/C] rs2969153 4 131457148 [A/C] rs1459308 4 131459940 [T/C] rs13105686 4 131468686 [T/C] rs4864001 4 131473531 [A/C] rs11099064 4 131484721 [A/C] rs13435727 4 131487361 [A/C] rs11945492 4 131494414 [A/G] rs10518572 4 131496373 [A/G] rs12642857 4 131498335 [A/G] rs2169718 4 131499709 [T/C] rs17051049 4 131501118 [T/C] rs4273485 4 131503899 [T/G] rs13125488 4 131508305 [T/C] rs4479720 4 131518894 [A/G] rs899131 4 131524184 [T/C] rs7664241 4 131526935 [T/C] rs1459288 4 131528197 [A/G] rs10518574 4 131528824 [T/C] rs2125639 4 131532350 [A/G] rs2085678 4 131536250 [A/G] rs2871751 4 131539495 [A/G] rs7668962 4 131540018 [A/G] rs7675752 4 131541099 [T/G] rs17051056 4 131545432 [T/C] rs7659897 4 131551052 [T/G] rs1948210 4 131558064 [T/C] rs2054931 4 131561136 [T/C] rs6534808 4 131568230 [A/C] rs1304183 4 131569148 [A/G] rs7687787 4 131578668 [A/G] rs1387452 4 131589008 [T/C] rs1032272 4 131589420 [A/G] rs1994541 4 131594623 [T/C] rs10006622 4 131596752 [T/C] rs4864014 4 131599180 [A/G] rs1489435 4 131599780 [A/G] rs1844327 4 131606179 [A/C] rs7674705 4 131611683 [T/C] rs2311780 4 131629960 [A/G] rs931418 4 131634859 [T/C] rs6811023 4 131638465 [A/G] rs10009557 4 131641319 [A/G] rs306344 4 131641387 [T/C] rs385027 4 131647396 [T/C] rs306369 4 131649821 [T/C] rs17051076 4 131650867 [A/G] rs306364 4 131652041 [T/C] rs17051078 4 131652629 [T/C] rs306353 4 131662183 [A/G] rs990046 4 131662676 [A/G] rs306350 4 131665353 [A/G] rs17051084 4 131671137 [T/C] rs11938827 4 131672725 [A/G] rs4146375 4 131680834 [T/C] rs11936306 4 131687922 [A/G] rs3113500 4 131695431 [A/G] rs3103398 4 131695570 [T/G] rs424918 4 131696764 [A/C] rs306377 4 131700214 [A/C] rs12505414 4 131701952 [A/C] rs11099081 4 131714357 [T/C] rs306393 4 131723626 [T/C] rs11099082 4 131724116 [T/G] rs2312337 4 131727377 [A/C] rs1824748 4 131727827 [T/C] rs1478075 4 131727847 [A/G] rs12651109 4 131747478 [A/G] rs12645823 4 131747961 [A/G] rs6854661 4 131750641 [A/C] rs6811623 4 131750954 [A/G] rs6836232 4 131772771 [A/G] rs1382171 4 131778067 [A/C] rs7440566 4 131779157 [T/C] rs13133329 4 131782781 [A/G] rs717469 4 131783960 [A/G] rs2035213 4 131787782 [A/C] rs6824018 4 131788216 [A/G] rs1478091 4 131790501 [T/C] rs6850860 4 131792029 [T/C] rs1478095 4 131804232 [A/G] rs2126823 4 131804615 [A/C] rs12711163 4 131809519 [T/C] rs13116382 4 131811462 [T/C] rs6847750 4 131814499 [T/C] rs17051105 4 131817577 [T/C] rs1382177 4 131824376 [A/G] rs4864021 4 131834405 [T/G] rs2173762 4 131837800 [A/C] rs11941740 4 131838432 [A/C] rs10010210 4 131838796 [T/C] rs11724421 4 131856379 [A/C] rs7658306 4 131857035 [A/G] rs1846790 4 131866484 [A/G] rs12498616 4 131866685 [A/G] rs9994110 4 131866907 [T/C] rs2055392 4 131868112 [A/C] rs12508862 4 131880992 [A/C] rs6830509 4 131884313 [A/C] rs2312546 4 131886381 [T/C] rs2872072 4 131887689 [T/C] rs17445005 4 131905081 [T/C] rs1500515 4 131916429 [T/C] rs11941696 4 131916948 [T/C] rs12647096 4 131920334 [T/G] rs9996563 4 131938086 [T/C] rs12642294 4 131939529 [A/G] rs4863838 4 131940633 [A/C] rs10006329 4 131941333 [T/C] rs6822842 4 131946375 [A/G] rs17051142 4 131963445 [T/C] rs3104157 4 131965131 [A/G] rs3104159 4 131969350 [A/G] rs13145260 4 131972377 [A/G] rs3104162 4 131973513 [A/G] rs1466742 4 131975827 [A/G] rs2220898 4 131983567 [A/G] rs440783 4 131985143 [T/C] rs17446401 4 131998959 [A/G] rs7692456 4 132008409 [A/C] rs4864029 4 132024484 [A/G] rs7659157 4 132031397 [T/C] rs10031771 4 132051076 [T/C] rs1353346 4 132052397 [T/C] rs12651384 4 132057086 [T/C] rs7690099 4 132080596 [T/C] rs12509451 4 132082388 [T/G] rs17447684 4 132118585 [A/C] rs6843806 4 132125400 [T/C] rs500131 4 132125839 [A/G] rs10018513 4 132126271 [A/G] rs490321 4 132129741 [A/G] rs9999452 4 132134734 [A/G] rs6811871 4 132143726 [T/C] rs10021892 4 132157647 [A/G] rs6855567 4 132169789 [T/C] rs12507587 4 132177261 [T/C] rs17051169 4 132177937 [T/C] rs11938816 4 132179341 [A/G] rs6534832 4 132179527 [A/G] rs11943774 4 132183047 [T/C] rs11943818 4 132183102 [T/C] rs6534833 4 132189098 [A/G] rs9992696 4 132192738 [A/C] rs11728768 4 132196533 [A/C] rs10008591 4 132218117 [T/C] rs12641430 4 132230540 [T/C] rs7677079 4 132231484 [T/C] rs10000209 4 132240434 [T/C] rs4133013 4 132242896 [T/C] rs1472909 4 132250203 [A/G] rs7676822 4 132252355 [T/G] rs1039782 4 132257490 [T/C] rs4585325 4 132282009 [T/C] rs1318943 4 132288496 [T/C] rs1911877 4 132298239 [T/C] rs4864039 4 132305574 [A/G] rs6534838 4 132310610 [A/G] rs17051182 4 132316034 [A/G] rs6811541 4 132328214 [A/G] rs17051193 4 132347889 [T/G] rs17457419 4 132351485 [A/G] rs7690600 4 132351655 [T/C] rs9993647 4 132354287 [T/G] rs7441235 4 132360407 [T/C] rs6823370 4 132363754 [T/C] rs1280680 4 132371344 [A/G] rs2662065 4 132381454 [A/G] rs10518597 4 132382377 [A/C] rs971005 4 132392727 [A/G] rs1280687 4 132399049 [A/C] rs1280699 4 132408562 [A/G] rs351098 4 132409029 [A/G] rs351096 4 132409579 [T/C] rs17458198 4 132413729 [T/C] rs17458385 4 132424332 [T/C] rs12506711 4 132426530 [A/G] rs1911889 4 132435333 [A/G] rs10857150 4 132443569 [A/G] rs7653972 4 132443909 [T/C] rs2036891 4 132455666 [A/C] rs1548174 4 132455995 [A/G] rs1705709 4 132456338 [A/G] rs1548157 4 132457822 [A/G] rs11099104 4 132460604 [T/G] rs4864048 4 132465027 [T/C] rs2062586 4 132474137 [T/C] rs11737708 4 132479903 [A/G] rs350959 4 132485551 [T/G] rs350995 4 132489231 [A/G] rs350993 4 132496097 [A/G] rs9997012 4 132496237 [T/G] rs13118882 4 132500347 [T/G] rs979640 4 132525794 [A/G] rs1511502 4 132526933 [A/G] rs350951 4 132535129 [A/G] rs17051227 4 132535239 [T/C] rs13121110 4 132540869 [T/C] rs13136106 4 132548856 [A/G] rs10003774 4 132551302 [T/C] rs6534848 4 132553385 [A/G] rs2088797 4 132556879 [T/G] rs1500780 4 132565470 [T/G] rs10002965 4 132565628 [A/C] rs1500777 4 132574038 [T/C] rs11931589 4 132575313 [A/C] rs2173805 4 132587682 [A/G] rs1909854 4 132595111 [A/G] rs350694 4 132610422 [A/G] rs1909852 4 132612328 [T/C] rs6837190 4 132686192 [T/C] NR_125883,NR_125884 SNHG27,SNHG27 EXON Silent,Silent rs13122986 4 132689843 [A/C] NR_125883,NR_125884 SNHG27,SNHG27 Silent,Silent rs2863673 4 132773067 [T/C] rs349293 4 132902055 [T/C] rs1367832 4 132914907 [A/C] rs11734516 4 132919103 [T/C] rs17468174 4 132921851 [T/C] rs17547161 4 132932804 [A/G] rs4863859 4 132932856 [A/G] rs6848554 4 132961872 [T/G] rs6849829 4 132962490 [T/C] rs1346962 4 132964641 [T/C] rs1431686 4 132980813 [T/C] rs11726701 4 132988240 [T/C] rs1505413 4 132999062 [A/G] rs10018031 4 133001527 [A/G] rs1431688 4 133003374 [T/G] rs4864099 4 133005854 [T/C] rs13108543 4 133016451 [A/G] rs1910873 4 133028269 [A/G] rs9996530 4 133047300 [A/G] rs11943359 4 133061307 [A/G] rs10461213 4 133062685 [T/C] rs10028352 4 133071142 [T/C] rs9992794 4 133082999 [T/C] rs6828393 4 133084358 [T/C] rs4479723 4 133084604 [T/G] rs6534877 4 133093090 [T/G] rs13137045 4 133101094 [T/C] rs10021585 4 133118600 [T/C] rs348071 4 133134553 [T/C] rs13150182 4 133145345 [T/C] rs17557587 4 133151211 [A/G] rs1603924 4 133156160 [T/C] rs6811696 4 133157721 [T/C] rs1499328 4 133165898 [T/C] rs6811946 4 133166779 [A/G] rs13434717 4 133173784 [A/G] rs17048863 4 133189144 [A/G] rs904516 4 133196593 [A/C] rs17048965 4 133198350 [T/G] rs967914 4 133199152 [T/G] rs1499319 4 133199870 [T/G] rs1392015 4 133205896 [T/C] rs17049065 4 133208543 [A/G] rs13103069 4 133223152 [A/G] rs6857942 4 133227636 [T/G] rs6835951 4 133231183 [T/G] rs13121719 4 133236522 [A/G] rs2062467 4 133236937 [A/G] rs17049500 4 133251547 [T/G] rs17559165 4 133254836 [T/G] rs17559291 4 133255316 [A/G] rs2062464 4 133261123 [T/C] rs12647936 4 133266400 [A/G] rs1499330 4 133278971 [T/C] rs10006396 4 133284503 [T/C] rs2088629 4 133287048 [T/C] rs6831400 4 133287497 [A/G] rs17559561 4 133289007 [A/G] rs17050168 4 133331707 [A/G] rs1499348 4 133353530 [A/G] rs1499349 4 133354687 [T/G] rs1995216 4 133363663 [T/C] rs1909456 4 133397984 [T/C] rs6812055 4 133407553 [A/G] rs6812131 4 133407753 [T/C] rs12505254 4 133423002 [A/G] rs955987 4 133427502 [T/C] rs2013016 4 133431421 [A/G] rs2419231 4 133440133 [T/C] rs13101445 4 133441627 [A/G] rs9307675 4 133441732 [A/G] rs1580810 4 133447771 [T/C] rs13147558 4 133458239 [T/C] rs11935217 4 133463042 [T/C] rs13139242 4 133463944 [T/C] rs4498140 4 133464597 [T/C] rs7695551 4 133466826 [A/G] rs13149899 4 133466974 [T/C] rs6849769 4 133469080 [T/C] rs13150301 4 133476393 [A/G] rs6856108 4 133479086 [A/G] rs6856692 4 133479165 [T/G] rs6814930 4 133480032 [A/G] rs1816512 4 133492317 [T/C] rs726332 4 133508013 [T/C] rs10518615 4 133513991 [A/G] NR_126401 LINC01256 Silent rs1435290 4 133517802 [A/G] NR_126401 LINC01256 Silent rs11732021 4 133519291 [A/G] NR_126401 LINC01256 Silent rs11723884 4 133519301 [A/G] NR_126401 LINC01256 Silent rs4863879 4 133527232 [T/C] NR_126401 LINC01256 Silent rs4864123 4 133529212 [T/C] NR_126401 LINC01256 Silent rs13107972 4 133530587 [A/G] NR_126401 LINC01256 Silent rs6844375 4 133530621 [A/G] NR_126401 LINC01256 Silent rs1946687 4 133534583 [A/C] NR_126401 LINC01256 Silent rs12510292 4 133535054 [T/G] NR_126401 LINC01256 Silent rs17563797 4 133537182 [T/C] NR_126401 LINC01256 Silent rs10033014 4 133541137 [T/C] NR_126401 LINC01256 Silent rs11942835 4 133550567 [A/G] NR_126401 LINC01256 Silent rs11944559 4 133560170 [T/G] NR_126401 LINC01256 Silent rs13142383 4 133561788 [T/C] NR_126401 LINC01256 Silent rs1435313 4 133562149 [T/C] NR_126401 LINC01256 Silent rs1583451 4 133577811 [T/C] NR_126401 LINC01256 Silent rs13131598 4 133581317 [A/G] NR_126401 LINC01256 Silent rs4864132 4 133585003 [T/G] NR_126401 LINC01256 Silent rs2419533 4 133589514 [A/G] NR_126401 LINC01256 Silent rs11099203 4 133597653 [A/G] NR_126401 LINC01256 Silent rs13141354 4 133600659 [A/G] rs11737152 4 133601521 [T/C] rs7689868 4 133603296 [T/C] rs1435305 4 133609486 [T/C] rs4441761 4 133621672 [A/G] rs10518617 4 133621825 [A/G] rs13143170 4 133622871 [A/G] rs12504144 4 133628547 [T/C] rs13117639 4 133637568 [T/C] rs13102108 4 133642296 [A/G] rs11722234 4 133648002 [A/G] rs7691446 4 133652752 [T/C] rs12645565 4 133671899 [A/G] rs10031562 4 133676609 [T/C] rs9999397 4 133680303 [A/G] rs13119882 4 133685637 [A/G] rs13133992 4 133687084 [T/G] rs11943009 4 133689782 [T/C] rs2419540 4 133690420 [A/G] rs11930973 4 133694117 [T/C] rs13132952 4 133694135 [A/G] rs7660359 4 133695623 [T/C] rs7665789 4 133703268 [T/C] rs12641171 4 133707298 [A/G] rs9996230 4 133714445 [T/C] rs11099215 4 133729234 [T/C] rs13137695 4 133740742 [T/C] rs1374944 4 133741753 [A/G] rs6534907 4 133743326 [T/C] rs17015765 4 133745514 [T/C] rs1020440 4 133750858 [T/C] rs1037177 4 133752631 [T/C] rs10518621 4 133764742 [T/C] rs11942306 4 133768010 [T/G] rs9991840 4 133769188 [T/G] rs17509240 4 133774665 [T/C] rs9994450 4 133775573 [T/C] rs4864153 4 133781039 [T/C] rs12501689 4 133786573 [A/G] rs10518627 4 133814532 [T/C] rs1349050 4 133821810 [T/C] rs4518260 4 133825466 [A/G] rs1447996 4 133826719 [T/C] rs12510100 4 133827600 [A/G] rs978335 4 133833738 [T/C] rs1448019 4 133839342 [T/C] rs1972970 4 133840998 [T/C] rs7683176 4 133842910 [T/C] rs1448029 4 133856236 [T/C] rs11099230 4 133858930 [A/G] rs12641896 4 133862954 [A/G] rs1448009 4 133876492 [T/C] rs17017843 4 133877679 [T/C] rs17017992 4 133887995 [A/G] rs7691971 4 133892106 [A/G] rs10518624 4 133906801 [T/C] rs10002224 4 133918746 [T/C] rs7675150 4 133955962 [T/C] rs10026639 4 133961722 [T/C] rs7699528 4 133981517 [A/G] rs6832145 4 133985941 [T/C] rs6840712 4 133987761 [T/C] rs7686916 4 134014299 [A/G] rs17585807 4 134030542 [A/G] NR_125885 LOC101927359 Silent rs12650564 4 134038614 [T/C] NR_125885 LOC101927359 Silent rs7685353 4 134040641 [T/C] NR_125885 LOC101927359 Silent rs4404561 4 134046930 [A/C] NR_125885 LOC101927359 Silent rs4864175 4 134062016 [A/C] NR_125885 LOC101927359 Silent rs925133 4 134065224 [T/G] NR_125885 LOC101927359 Silent rs28565197 4 134069362 [A/C] NR_125885 LOC101927359 Silent rs13144059 4 134072264 [A/G] NM_032961,NM_020815 PCDH10,PCDH10 EXON Synonymous_V323V,Synonymous_V323V rs3749589 4 134074058 [A/G] NM_032961,NM_020815 PCDH10,PCDH10 EXON Silent,Silent rs2271171 4 134076153 [T/C] NM_032961 PCDH10 EXON Synonymous_D924D rs1396009 4 134081686 [A/G] NM_032961 PCDH10 Silent rs9307688 4 134083486 [T/C] NM_032961 PCDH10 Silent rs10084852 4 134083809 [T/C] NM_032961 PCDH10 Silent rs10518630 4 134091734 [A/G] NM_032961 PCDH10 Silent rs10030948 4 134112790 [T/C] NM_032961 PCDH10 EXON Silent rs6846610 4 134120109 [T/C] rs2420155 4 134120138 [T/G] rs7663268 4 134123827 [T/C] rs971869 4 134124586 [A/G] rs13122589 4 134127276 [A/C] rs6534937 4 134134331 [A/G] rs7676691 4 134139650 [T/C] rs976259 4 134153787 [T/C] rs11936591 4 134154732 [T/C] rs17021448 4 134164619 [A/G] rs7675918 4 134169341 [T/C] rs10213462 4 134201076 [A/G] rs10213461 4 134201194 [T/C] rs7677931 4 134203735 [A/G] rs13115954 4 134221580 [T/C] rs7684286 4 134223023 [T/C] rs1346065 4 134223969 [A/G] rs17022723 4 134238544 [T/C] rs6843762 4 134246761 [T/G] rs1895778 4 134266978 [T/C] rs13101921 4 134274037 [T/G] rs6818278 4 134291887 [T/C] rs10518633 4 134293912 [T/C] rs10031161 4 134298899 [T/C] rs6857817 4 134303084 [T/C] rs1425565 4 134312838 [A/G] rs2009274 4 134319928 [A/C] rs1425562 4 134322289 [T/C] rs1834407 4 134326078 [A/C] rs10518635 4 134330928 [T/C] rs1389331 4 134335871 [T/C] rs1493499 4 134340488 [A/G] rs7679087 4 134343880 [A/G] rs13127497 4 134346117 [T/C] rs17024567 4 134352803 [A/C] rs1032439 4 134352903 [A/G] rs11099240 4 134357855 [T/G] rs13107301 4 134358917 [T/C] rs17024656 4 134359051 [T/G] rs2420407 4 134376495 [A/G] rs13149700 4 134379548 [A/C] rs12498624 4 134380159 [T/C] rs7375925 4 134384370 [A/G] rs17024794 4 134384791 [T/C] rs7662704 4 134389485 [A/C] rs1493508 4 134391195 [T/C] rs1908125 4 134392080 [T/C] rs11935955 4 134394882 [A/C] rs11732664 4 134396454 [T/C] rs12505494 4 134397039 [T/C] rs1493493 4 134398990 [T/C] rs17025316 4 134409421 [A/C] rs7696123 4 134415283 [A/G] rs6839762 4 134425824 [T/G] rs4593189 4 134439150 [T/C] rs12500334 4 134448546 [T/C] rs6836197 4 134458405 [T/C] rs1032438 4 134463193 [T/C] rs1493517 4 134471862 [T/C] rs1565733 4 134478128 [T/C] rs903092 4 134482149 [T/C] rs903094 4 134482324 [A/G] rs13106321 4 134489656 [T/C] rs12508742 4 134514218 [T/G] rs10518641 4 134522725 [A/G] rs925084 4 134530386 [T/G] rs906372 4 134535101 [T/C] rs13101958 4 134538656 [A/G] rs2713289 4 134540393 [T/C] rs7676258 4 134553039 [T/C] rs7700155 4 134570882 [A/G] rs1948964 4 134572146 [T/G] rs4864206 4 134576263 [T/C] rs1567176 4 134578828 [T/G] rs3849650 4 134594864 [T/G] rs1395763 4 134603887 [A/G] rs1116243 4 134622098 [A/G] rs2724267 4 134626218 [T/C] rs2660733 4 134627285 [T/C] rs2724272 4 134639697 [T/G] rs10518642 4 134640333 [T/C] rs12508593 4 134670981 [A/G] rs10001280 4 134677231 [T/G] rs13135185 4 134706510 [A/G] rs7668810 4 134710417 [T/C] rs4613620 4 134714897 [T/C] rs4505885 4 134733250 [A/G] rs10006443 4 134748873 [A/G] rs10034320 4 134754555 [T/C] rs4541580 4 134763851 [A/G] rs10084961 4 134766022 [T/C] rs4293839 4 134768896 [T/C] rs12499235 4 134775136 [T/C] rs4629515 4 134777686 [T/G] rs4582208 4 134782403 [T/C] rs6811342 4 134784379 [A/G] rs17611459 4 134788400 [T/C] rs10213217 4 134800222 [A/G] rs4415013 4 134815036 [A/G] rs17540695 4 134847697 [A/G] rs11099261 4 134848916 [T/G] rs10001384 4 134860496 [A/G] rs7340759 4 134865463 [A/C] rs6840096 4 134869724 [A/G] rs10000682 4 134872709 [A/G] rs11731250 4 134888185 [A/G] rs12508354 4 134889067 [T/G] rs7664989 4 134919765 [A/C] rs17613678 4 134924076 [A/G] rs17031068 4 134930037 [A/G] rs17613932 4 134940358 [A/G] rs1494978 4 134947801 [A/G] rs17542016 4 134952210 [A/G] rs1495000 4 134963379 [T/C] rs11099266 4 134964519 [T/C] rs6839208 4 134964598 [A/G] rs12642075 4 134972554 [A/G] rs1126293 4 134984561 [A/G] rs6534996 4 134997723 [T/C] rs1494996 4 135004435 [T/G] rs1390022 4 135019322 [T/C] rs1494989 4 135019690 [A/G] rs1390021 4 135020910 [A/G] rs10518647 4 135033482 [A/G] rs1494984 4 135046236 [T/C] rs3980965 4 135062735 [T/G] rs2088124 4 135090280 [A/G] rs11099273 4 135121066 [T/G] NM_001363585,NM_001114734 PABPC4L,PABPC4L EXON Missense_H370P,Missense_H370P rs2044116 4 135121368 [T/G] NM_001363585,NM_001114734 PABPC4L,PABPC4L EXON Synonymous_V269V,Synonymous_V269V rs10009368 4 135121601 [T/C] NM_001363585,NM_001114734 PABPC4L,PABPC4L EXON Missense_V192I,Missense_V192I rs17033938 4 135126327 [A/G] rs4337777 4 135137960 [T/C] rs1017507 4 135142988 [T/G] rs17034156 4 135144904 [T/C] rs2901383 4 135149801 [T/C] rs6822094 4 135176705 [T/C] rs10015286 4 135183337 [T/C] rs17035063 4 135195682 [A/G] rs10019779 4 135202678 [A/C] rs11733152 4 135206722 [T/C] rs11935714 4 135211409 [T/C] rs12504980 4 135227570 [A/C] rs17553221 4 135250225 [T/G] rs12649164 4 135252930 [T/C] rs1486983 4 135278000 [T/C] rs6856274 4 135278673 [A/G] rs1386363 4 135288420 [T/C] rs1601648 4 135294098 [T/C] rs1486994 4 135297475 [T/C] rs10518652 4 135303908 [T/C] rs17036736 4 135310068 [T/C] rs12644853 4 135312908 [T/G] rs2421334 4 135317096 [T/C] rs12510007 4 135332361 [A/C] rs1486978 4 135339629 [T/G] rs17037260 4 135345377 [T/C] NR_147155 LINC02462 Silent rs11729282 4 135358154 [T/C] NR_147155 LINC02462 Silent rs11730209 4 135385287 [T/C] NR_147155 LINC02462 Silent rs977851 4 135399300 [T/G] NR_147155 LINC02462 Silent rs983035 4 135410583 [T/C] NR_147155 LINC02462 Silent rs13129759 4 135420199 [T/C] NR_147155 LINC02462 Silent rs10006423 4 135421707 [T/C] NR_147155 LINC02462 Silent rs4388143 4 135428455 [A/C] NR_147155 LINC02462 Silent rs5013339 4 135428504 [T/C] NR_147155 LINC02462 Silent rs13140370 4 135430486 [T/C] NR_147155 LINC02462 Silent rs11099284 4 135438724 [T/C] NR_147155 LINC02462 Silent rs6844188 4 135454396 [A/G] NR_147155 LINC02462 Silent rs6535025 4 135457628 [A/G] NR_147155 LINC02462 Silent rs11934048 4 135474690 [A/G] rs4479759 4 135514757 [A/G] rs4452492 4 135523007 [T/G] rs4416534 4 135529480 [T/C] rs6535028 4 135537719 [T/C] rs10010236 4 135547294 [A/G] rs6827297 4 135554935 [T/G] rs4475200 4 135580589 [T/C] rs10020543 4 135598459 [A/G] rs2404308 4 135610277 [A/G] rs16998192 4 135623679 [A/G] rs7672011 4 135623942 [A/C] rs6535038 4 135643583 [A/G] rs10519337 4 135655677 [A/G] rs586090 4 135659888 [T/C] rs11938483 4 135678228 [A/C] rs1506621 4 135685643 [A/G] rs548172 4 135686477 [T/C] rs644708 4 135687493 [T/C] rs7693807 4 135697955 [A/C] rs4863918 4 135698868 [T/C] rs514587 4 135709542 [T/C] rs28791792 4 135713101 [A/G] rs1354750 4 135726024 [T/C] rs13144694 4 135735591 [A/G] rs10155476 4 135735630 [A/G] rs9996717 4 135738792 [T/C] rs11934675 4 135740001 [A/G] rs7667372 4 135741863 [A/C] rs2055671 4 135766067 [A/C] rs2055670 4 135766089 [T/G] rs17573425 4 135768224 [A/G] rs13119012 4 135772152 [T/C] rs10013441 4 135775238 [T/C] rs12505192 4 135778261 [A/G] rs7684927 4 135779831 [T/C] rs13130652 4 135787960 [A/C] rs4412039 4 135788408 [A/G] rs4864233 4 135792739 [T/C] rs6853230 4 135793327 [T/G] rs2896920 4 135795762 [T/G] rs10034996 4 135796837 [A/G] rs6856596 4 135798890 [A/G] rs6813668 4 135803220 [T/C] rs10010200 4 135818060 [A/G] rs10008735 4 135829981 [A/G] rs11737779 4 135831516 [A/G] rs11722290 4 135832268 [T/C] rs9998198 4 135838960 [A/G] rs9998469 4 135839182 [A/G] rs4290941 4 135860798 [A/G] rs11938033 4 135864154 [T/C] rs7692242 4 135886041 [A/G] rs13102973 4 135900688 [T/C] rs7668080 4 135911869 [T/C] rs13140134 4 135912595 [T/C] rs4343778 4 135916528 [A/C] rs4452493 4 135916968 [A/G] rs4361440 4 135918927 [T/C] rs12509818 4 135928708 [T/C] rs6826932 4 135935686 [A/C] rs4527530 4 135939520 [T/C] rs4507423 4 135949225 [T/C] rs6535065 4 135953351 [T/C] rs4565135 4 135954321 [T/C] rs4563542 4 135954367 [A/C] rs4292380 4 135954865 [A/G] rs4530692 4 135966148 [A/G] rs28568985 4 135966595 [T/C] rs28703919 4 135966954 [T/C] rs12509986 4 135974322 [T/C] rs11730178 4 135976246 [T/C] rs6856823 4 135987864 [T/C] rs7664664 4 135989375 [A/G] rs7687865 4 136008847 [A/G] rs12647065 4 136012580 [T/C] rs11099317 4 136020662 [A/G] rs4133331 4 136022178 [T/C] rs4128296 4 136024521 [T/C] rs9997836 4 136034687 [T/G] NR_147187 LINC02485 Silent rs10034725 4 136037190 [A/G] NR_147187 LINC02485 Silent rs4330400 4 136037410 [A/G] NR_147187 LINC02485 Silent rs4452495 4 136042022 [A/C] NR_147187 LINC02485 Silent rs4128811 4 136057950 [A/G] rs4501276 4 136064120 [T/C] rs11099320 4 136068696 [T/C] rs2404639 4 136074901 [T/C] rs11099322 4 136078993 [A/G] rs12505219 4 136079340 [A/C] rs11734733 4 136084138 [T/C] rs10009456 4 136094675 [T/G] rs7658327 4 136111450 [A/C] rs10519350 4 136111898 [T/G] rs10014016 4 136120558 [A/G] rs13101517 4 136123827 [T/C] rs1841409 4 136125132 [T/C] rs10519351 4 136131907 [T/G] rs11099332 4 136147584 [A/G] rs1824483 4 136148697 [T/C] rs2219587 4 136151551 [T/C] rs17638685 4 136164162 [A/G] rs4356958 4 136176700 [T/C] rs2054294 4 136179916 [T/C] rs9307730 4 136187386 [T/C] rs17639159 4 136192112 [T/C] rs1460689 4 136199802 [T/G] rs1460686 4 136211250 [T/C] rs1460687 4 136217865 [T/C] rs1460682 4 136223378 [A/G] rs9307731 4 136232574 [T/C] rs6844518 4 136242130 [T/C] rs1460691 4 136257232 [A/C] rs13147783 4 136258488 [T/C] rs1380900 4 136263707 [A/C] rs2035469 4 136288768 [A/G] rs6848293 4 136294099 [T/C] rs4864269 4 136302270 [A/G] rs12510384 4 136302474 [A/G] rs11099340 4 136311803 [A/G] rs1905461 4 136316187 [T/G] rs10519357 4 136319647 [A/G] rs13135756 4 136339396 [T/C] rs316693 4 136354391 [T/C] rs13121167 4 136374817 [T/G] rs13112126 4 136374928 [A/C] rs17579742 4 136381862 [T/C] rs984160 4 136406835 [A/G] rs17641646 4 136415590 [T/C] rs11099346 4 136417496 [A/C] rs10014428 4 136421815 [T/G] rs13110301 4 136422205 [T/C] rs1382998 4 136426582 [T/C] rs2404866 4 136445508 [A/G] rs1479776 4 136453566 [T/C] rs2054502 4 136453779 [T/G] rs1871490 4 136455685 [T/C] rs17047924 4 136464719 [T/C] rs12503254 4 136466850 [A/C] rs17047931 4 136467679 [A/G] rs17581218 4 136468089 [T/C] rs7340923 4 136482197 [T/C] rs6857087 4 136485458 [T/C] rs17047940 4 136486203 [T/G] rs17648258 4 136490362 [A/C] rs931121 4 136491544 [A/G] rs2101018 4 136494967 [A/C] rs11935796 4 136496620 [A/G] rs1382988 4 136499081 [A/G] rs4146972 4 136503631 [T/C] rs2086327 4 136510557 [A/C] rs13117043 4 136511399 [A/G] rs1038151 4 136512755 [T/G] rs7692855 4 136516456 [T/C] rs2404867 4 136519891 [A/C] rs11737486 4 136521106 [A/G] rs10029804 4 136525023 [T/C] rs7685332 4 136543136 [T/C] rs905772 4 136543541 [T/C] rs7666345 4 136549624 [T/C] rs17649956 4 136561308 [T/C] rs1610224 4 136566098 [A/G] rs1610225 4 136566650 [A/G] rs17048026 4 136570472 [T/G] rs958632 4 136572585 [A/G] rs1354539 4 136586509 [A/G] rs1504865 4 136591498 [A/C] rs12505927 4 136599787 [A/G] rs1566874 4 136606270 [A/G] rs11734150 4 136613685 [A/G] rs1394542 4 136614519 [T/C] rs13127387 4 136618495 [A/G] rs2174391 4 136633424 [A/G] rs963645 4 136649383 [A/C] rs2134985 4 136650042 [T/G] rs6811227 4 136651244 [T/C] rs10006644 4 136653344 [T/G] rs13111781 4 136653594 [T/C] rs7655183 4 136660767 [A/G] rs2134987 4 136667668 [T/G] rs1354538 4 136681841 [A/C] rs1604945 4 136688436 [A/G] rs2018601 4 136694463 [T/C] rs6816688 4 136696628 [A/G] rs17048197 4 136698656 [T/C] rs1504860 4 136709014 [A/G] rs6535115 4 136711280 [T/C] rs10028711 4 136716868 [T/C] rs12500395 4 136724563 [T/C] rs7657021 4 136727025 [T/C] rs12513116 4 136727303 [A/C] rs4311361 4 136728487 [A/G] rs11099363 4 136730024 [A/G] rs6535121 4 136737730 [A/G] rs2068179 4 136741799 [A/G] rs6852986 4 136754367 [A/G] rs6853180 4 136754442 [A/G] rs10005321 4 136754993 [A/G] rs4443343 4 136755136 [T/C] rs4302513 4 136755552 [A/G] rs6535122 4 136760894 [A/G] rs7672503 4 136763493 [A/G] rs12645397 4 136764416 [A/C] rs4610390 4 136778939 [T/C] rs6858770 4 136818726 [T/C] NR_103763 LINC00613 Silent rs7671791 4 136826636 [A/G] NR_103763 LINC00613 Silent rs11722042 4 136828780 [T/C] NR_103763 LINC00613 Silent rs4863945 4 136837128 [T/C] rs11734469 4 136844538 [T/G] rs4339269 4 136847562 [T/C] rs12509309 4 136866722 [A/G] rs12507949 4 136871982 [A/G] rs7679231 4 136882276 [T/G] rs4318703 4 136910271 [A/G] rs4455480 4 136910907 [A/G] rs11733579 4 136919049 [T/C] rs4552531 4 136934240 [T/G] rs4580703 4 136940740 [T/G] rs2405496 4 136954732 [A/C] rs6535135 4 136958364 [T/G] rs4863947 4 136978022 [A/C] rs17048434 4 136984338 [T/C] rs10519374 4 136993300 [T/C] rs4145876 4 137003101 [T/C] rs2222654 4 137006061 [T/C] rs17048466 4 137016357 [A/G] rs1344033 4 137018385 [A/C] rs12511521 4 137021516 [A/G] rs10013192 4 137023288 [A/G] rs7675695 4 137043545 [T/C] rs1917955 4 137053594 [T/C] rs10001369 4 137067061 [T/G] rs2598548 4 137069206 [A/G] rs1451109 4 137071335 [A/G] rs1724560 4 137073260 [T/C] rs1724563 4 137074119 [A/C] rs1283040 4 137081250 [T/C] rs1296328 4 137083193 [A/C] rs1283049 4 137088592 [T/C] rs2897153 4 137105336 [A/G] rs2693428 4 137115636 [T/C] rs2034535 4 137116996 [T/C] rs17048542 4 137124831 [T/C] rs10009269 4 137136262 [T/C] rs12506698 4 137138361 [T/C] rs2053896 4 137154796 [A/G] rs11945964 4 137178274 [T/C] rs968639 4 137181847 [A/G] rs1451111 4 137196244 [A/G] rs1597600 4 137206602 [T/C] rs17048581 4 137210298 [T/C] rs11723419 4 137213250 [A/C] rs6857747 4 137213987 [T/G] rs11099379 4 137223663 [T/C] rs2110186 4 137233717 [A/G] rs2192201 4 137241357 [A/G] rs1558514 4 137246038 [T/C] rs10026312 4 137247266 [T/C] rs10007624 4 137252090 [A/G] rs11947164 4 137253127 [T/C] rs6858670 4 137258380 [T/C] rs13102201 4 137259372 [A/C] rs10013817 4 137259828 [A/G] rs11099384 4 137267384 [A/G] rs2215748 4 137289228 [A/C] rs17048626 4 137299152 [A/C] rs13110422 4 137318397 [T/C] rs4864340 4 137323344 [A/G] rs7682599 4 137324597 [T/C] rs17048646 4 137328242 [A/G] rs10489022 4 137332146 [A/G] rs10489023 4 137333550 [A/G] rs17719661 4 137335125 [A/G] rs13132705 4 137335180 [T/G] rs13146292 4 137336902 [T/G] rs6822167 4 137339805 [A/C] rs11732083 4 137349221 [A/C] rs982315 4 137355816 [T/C] rs2016184 4 137358857 [A/C] rs13106779 4 137359917 [A/G] rs6848260 4 137364012 [T/C] rs1476909 4 137364820 [A/G] rs2215746 4 137376628 [T/G] rs17721005 4 137382422 [T/C] rs6848692 4 137396283 [A/G] rs6854954 4 137397046 [A/G] rs7657066 4 137397892 [A/G] rs1860966 4 137402211 [T/C] rs6535149 4 137408872 [T/C] rs7662012 4 137409145 [A/G] rs10028445 4 137413277 [T/C] rs6853939 4 137414375 [T/C] rs12505589 4 137417231 [T/C] rs6838151 4 137417550 [A/G] rs6855815 4 137423151 [T/C] rs7678967 4 137423956 [A/G] rs10000852 4 137429284 [T/G] rs13104804 4 137429980 [A/G] rs12503505 4 137445190 [A/G] rs6535158 4 137445988 [T/C] rs4315856 4 137454023 [A/G] rs9685146 4 137474142 [T/G] rs12646490 4 137478671 [A/G] rs9683947 4 137479869 [A/G] rs11733040 4 137480493 [A/G] rs4607283 4 137483215 [T/C] rs10519392 4 137485929 [A/G] rs1343837 4 137493086 [A/G] rs1317842 4 137493839 [A/G] rs6824877 4 137500020 [T/C] rs7695493 4 137504762 [A/G] rs7682676 4 137518143 [A/C] rs4304024 4 137524479 [A/C] rs13115947 4 137524981 [A/G] rs10012428 4 137526751 [T/G] rs17048799 4 137529812 [T/C] rs11099401 4 137533307 [T/C] rs12509153 4 137533710 [A/C] rs12509396 4 137534902 [T/C] rs2406020 4 137535800 [T/C] rs4864355 4 137535918 [A/G] rs6815580 4 137539440 [T/C] rs2405826 4 137542931 [A/G] rs13125562 4 137551442 [A/G] rs2406055 4 137567044 [T/C] rs17615017 4 137573355 [A/G] rs7685386 4 137573579 [T/C] rs6812959 4 137581282 [A/G] rs13115339 4 137584945 [T/G] rs11728206 4 137589137 [T/C] rs2406041 4 137590858 [A/G] rs2406040 4 137590890 [T/C] rs2406037 4 137591468 [T/C] rs12512934 4 137593405 [T/C] rs12513015 4 137593654 [T/G] rs7658823 4 137599574 [A/C] rs10519394 4 137604609 [A/C] rs10519395 4 137604986 [A/G] rs17048865 4 137612032 [A/C] rs17048874 4 137614143 [A/C] rs2125883 4 137626639 [T/C] rs28414099 4 137628416 [T/C] rs2612181 4 137632211 [T/C] rs7658630 4 137634247 [A/G] rs1460160 4 137634874 [A/G] rs6832309 4 137638537 [T/G] rs13109827 4 137643932 [T/C] rs6831651 4 137647418 [A/G] rs9996792 4 137650213 [A/G] rs10003357 4 137652477 [A/G] rs13120314 4 137654086 [T/G] rs10009978 4 137654857 [T/C] rs17617045 4 137657271 [T/C] rs1460155 4 137662425 [A/G] rs7692053 4 137662604 [A/G] rs6833955 4 137665438 [A/G] rs4863961 4 137668842 [T/C] rs2406056 4 137669227 [A/G] rs736339 4 137671615 [T/C] rs17673757 4 137673414 [A/G] rs1460138 4 137676856 [A/C] rs17048925 4 137677024 [T/G] rs17674050 4 137679664 [T/C] rs10519397 4 137682275 [A/C] rs17048948 4 137683836 [T/C] rs1460157 4 137684462 [T/C] rs2634904 4 137689373 [A/G] rs17048962 4 137690122 [T/C] rs6842883 4 137691499 [A/G] rs2011114 4 137692712 [T/G] rs17680173 4 137693116 [T/C] rs11733819 4 137694429 [T/C] rs10016963 4 137697208 [A/C] rs2612182 4 137698875 [T/C] rs1841293 4 137704034 [T/G] rs17680592 4 137706263 [T/C] rs1460148 4 137707853 [T/C] rs7686560 4 137710655 [T/C] rs10857199 4 137712561 [T/G] rs17619001 4 137713519 [T/C] rs9990891 4 137713685 [A/G] rs2634888 4 137714170 [A/G] rs4864364 4 137718455 [A/G] NR_149105 LINC02511 EXON Silent rs17829074 4 137720486 [T/C] NR_149105 LINC02511 Silent rs2612144 4 137727040 [A/G] NR_149105 LINC02511 Silent rs2169147 4 137727533 [T/C] NR_149105 LINC02511 Silent rs13132581 4 137727894 [A/G] NR_149105 LINC02511 Silent rs7662945 4 137727959 [A/G] NR_149105 LINC02511 Silent rs4241970 4 137729375 [T/C] NR_149105 LINC02511 Silent rs17049031 4 137731357 [A/G] NR_149105 LINC02511 Silent rs4864365 4 137733154 [A/G] NR_149105 LINC02511 Silent rs2634900 4 137733596 [A/C] NR_149105 LINC02511 Silent rs2612134 4 137733835 [A/C] NR_149105 LINC02511 Silent rs1551705 4 137735357 [A/G] NR_149105 LINC02511 Silent rs13101322 4 137736095 [T/G] NR_149105 LINC02511 Silent rs898427 4 137740596 [T/C] NR_149105 LINC02511 Silent rs2612121 4 137743560 [T/C] NR_149105 LINC02511 Silent rs12503089 4 137744065 [T/G] NR_149105 LINC02511 Silent rs7658921 4 137745250 [A/C] NR_149105 LINC02511 Silent rs9884859 4 137746765 [T/C] NR_149105 LINC02511 Silent rs1380627 4 137755834 [T/C] NR_149105 LINC02511 Silent rs2634862 4 137757203 [T/C] NR_149105 LINC02511 Silent rs2612131 4 137757692 [T/C] NR_149105 LINC02511 Silent rs6846036 4 137758397 [T/C] NR_149105 LINC02511 Silent rs2009775 4 137760899 [T/C] NR_149105 LINC02511 Silent rs2612165 4 137761486 [T/C] NR_149105 LINC02511 Silent rs11732418 4 137763599 [A/G] NR_149105 LINC02511 Silent rs6842060 4 137775757 [T/C] NR_149105 LINC02511 Silent rs10519401 4 137778900 [T/C] NR_149105 LINC02511 Silent rs6842381 4 137779128 [A/C] NR_149105 LINC02511 Silent rs2590762 4 137804904 [T/C] NR_149105 LINC02511 Silent rs7698161 4 137808928 [T/C] NR_149105 LINC02511 Silent rs7685312 4 137814303 [A/G] NR_149105 LINC02511 Silent rs11099419 4 137816124 [A/G] NR_149105 LINC02511 Silent rs2634870 4 137817015 [A/G] NR_149105 LINC02511 Silent rs17049094 4 137818861 [T/C] NR_149105 LINC02511 Silent rs1992694 4 137822979 [T/C] NR_149105 LINC02511 Silent rs10007934 4 137824601 [A/G] NR_149105 LINC02511 Silent rs2034212 4 137828416 [A/G] NR_149105 LINC02511 Silent rs1445523 4 137828866 [T/C] NR_149105 LINC02511 Silent rs12331904 4 137832558 [T/C] NR_149105 LINC02511 Silent rs994911 4 137834818 [A/G] NR_149105 LINC02511 Silent rs13124866 4 137834834 [A/G] NR_149105 LINC02511 Silent rs994912 4 137834967 [T/G] NR_149105 LINC02511 Silent rs7692485 4 137838411 [T/C] NR_149105 LINC02511 Silent rs1445520 4 137840213 [T/C] NR_149105 LINC02511 Silent rs7677705 4 137842889 [A/G] NR_149105 LINC02511 Silent rs17049140 4 137845624 [T/C] NR_149105 LINC02511 Silent rs17049142 4 137847693 [T/C] NR_149105 LINC02511 Silent rs12500811 4 137851689 [A/G] NR_149105 LINC02511 Silent rs1373895 4 137851858 [T/C] NR_149105 LINC02511 Silent rs693365 4 137852484 [A/G] NR_149105 LINC02511 Silent rs1400918 4 137874783 [T/C] NR_149105 LINC02511 Silent rs10519404 4 137875449 [T/C] NR_149105 LINC02511 Silent rs17049170 4 137878063 [A/G] NR_149105 LINC02511 Silent rs480003 4 137879617 [A/G] NR_149105 LINC02511 Silent rs7695609 4 137886834 [A/G] NR_149105 LINC02511 Silent rs17049203 4 137900265 [A/G] NR_149105 LINC02511 Silent rs1517955 4 137912755 [T/C] NR_149105 LINC02511 Silent rs1517956 4 137912903 [T/C] NR_149105 LINC02511 Silent rs1996452 4 137914565 [A/G] NR_149105 LINC02511 Silent rs679959 4 137923777 [A/G] NR_149105 LINC02511 Silent rs1517944 4 137937395 [T/C] NR_149105 LINC02511 Silent rs1517945 4 137938336 [T/C] NR_149105 LINC02511 Silent rs529654 4 137944935 [A/G] NR_149105 LINC02511 Silent rs572260 4 137947710 [A/G] NR_149105 LINC02511 Silent rs515800 4 137953807 [T/C] NR_149105 LINC02511 Silent rs534612 4 137954283 [A/G] NR_149105 LINC02511 Silent rs545844 4 137964269 [T/C] NR_149105 LINC02511 Silent rs481565 4 137966680 [T/C] NR_149105 LINC02511 Silent rs17049291 4 137968302 [A/G] NR_149105 LINC02511 Silent rs7661485 4 137976550 [A/G] NR_149105 LINC02511 Silent rs11735377 4 137984231 [A/G] NR_149105 LINC02511 Silent rs17049311 4 137985807 [T/C] NR_149105 LINC02511 Silent rs7692042 4 137986252 [T/C] NR_149105 LINC02511 Silent rs10049824 4 137986727 [T/C] NR_149105 LINC02511 Silent rs1607297 4 137989297 [A/C] NR_149105 LINC02511 Silent rs598364 4 137989392 [A/G] NR_149105 LINC02511 Silent rs12511969 4 137990451 [A/G] NR_149105 LINC02511 Silent rs720733 4 137997347 [T/C] NR_149105 LINC02511 Silent rs12510407 4 137997845 [T/C] NR_149105 LINC02511 Silent rs17698183 4 137998971 [A/G] NR_149105 LINC02511 Silent rs12647735 4 137999526 [A/C] NR_149105 LINC02511 Silent rs1456266 4 138002681 [T/G] NR_149105 LINC02511 Silent rs10018409 4 138004950 [T/C] NR_149105 LINC02511 Silent rs10519416 4 138010057 [T/C] NR_149105 LINC02511 Silent rs1542389 4 138016196 [T/C] NR_149105 LINC02511 Silent rs1118368 4 138038058 [T/C] NR_149105 LINC02511 Silent rs7692372 4 138042250 [T/G] NR_149105 LINC02511 Silent rs10519415 4 138044886 [T/G] NR_149105 LINC02511 Silent rs17642711 4 138048759 [T/C] NR_149105 LINC02511 Silent rs12505431 4 138049464 [A/G] NR_149105 LINC02511 Silent rs17049362 4 138052684 [T/G] NR_149105 LINC02511 Silent rs11944907 4 138054384 [A/G] NR_149105 LINC02511 Silent rs989519 4 138080761 [A/C] NR_149105 LINC02511 Silent rs10010440 4 138087831 [T/G] NR_149105 LINC02511 Silent rs1913606 4 138103313 [A/G] NR_149105 LINC02511 Silent rs7660328 4 138111659 [A/G] NR_149105 LINC02511 Silent rs9307765 4 138115250 [A/G] NR_149105,NR_134640 LINC02511,LINC02510 EXON Silent,Silent rs10049625 4 138118313 [T/C] NR_149105,NR_134640 LINC02511,LINC02510 Silent,Silent rs4145 4 138118550 [A/G] NR_149105,NR_134640 LINC02511,LINC02510 EXON Silent,Silent rs13148112 4 138118905 [A/G] NR_149105,NR_134640 LINC02511,LINC02510 EXON Silent,Silent rs4577637 4 138119828 [A/G] NR_149105,NR_134640 LINC02511,LINC02510 EXON Silent,Silent rs1124481 4 138121754 [A/G] NR_149105 LINC02511 Silent rs10008805 4 138126978 [T/C] NR_149105 LINC02511 Silent rs12642406 4 138128533 [T/G] NR_149105 LINC02511 Silent rs10519412 4 138129929 [T/C] NR_149105 LINC02511 Silent rs7696692 4 138145125 [T/C] rs10004839 4 138154812 [T/C] rs2081521 4 138157047 [A/G] rs2406716 4 138160754 [T/C] rs4561979 4 138161364 [T/C] rs17701651 4 138161923 [T/C] rs1425979 4 138164950 [T/G] rs1365138 4 138167524 [T/C] rs1425982 4 138168552 [T/C] rs1425983 4 138168682 [A/C] rs6816675 4 138171595 [A/G] rs17049477 4 138183847 [A/G] rs7681206 4 138185006 [A/G] rs736733 4 138187352 [T/G] rs6535206 4 138190394 [T/G] rs10012193 4 138197514 [A/C] rs12505076 4 138206940 [A/C] rs7670687 4 138213225 [A/G] rs6832097 4 138218981 [A/G] rs6847311 4 138221687 [A/G] rs1425969 4 138224531 [T/C] rs1365132 4 138226204 [A/G] rs987360 4 138227609 [T/C] rs768728 4 138227898 [T/G] rs13129710 4 138229547 [T/C] rs17049516 4 138229727 [A/G] rs1365133 4 138238306 [T/G] rs10857203 4 138247146 [A/G] rs1425993 4 138247502 [T/G] rs7672454 4 138261366 [A/G] rs1991260 4 138279041 [A/G] rs10519423 4 138279845 [A/G] rs17049529 4 138281281 [A/G] rs6811274 4 138283405 [T/C] rs7692730 4 138287439 [A/C] rs11730485 4 138293584 [A/C] rs17049537 4 138294300 [A/C] rs6831492 4 138299994 [T/C] rs11929773 4 138301340 [T/G] rs17049542 4 138305971 [A/C] rs10519420 4 138313173 [T/C] rs13118887 4 138328077 [A/G] rs5020420 4 138333658 [T/C] rs7699794 4 138346339 [A/G] rs17049574 4 138346981 [A/C] rs17049579 4 138348864 [A/C] rs6831421 4 138349799 [A/G] rs11936879 4 138352416 [T/C] rs6811783 4 138355102 [T/C] rs17207630 4 138356364 [A/G] rs10007008 4 138366488 [T/C] rs7698992 4 138367052 [T/C] rs2406747 4 138367353 [T/C] rs17049611 4 138367672 [T/C] rs4398579 4 138367713 [A/C] rs10519425 4 138369786 [A/G] rs17049637 4 138369854 [A/G] rs6535218 4 138370960 [A/C] rs7660985 4 138372112 [T/C] rs4864420 4 138374116 [T/G] rs7679076 4 138380321 [A/C] rs12498882 4 138381268 [T/C] rs12500066 4 138382556 [T/C] rs2406756 4 138390066 [A/G] rs1320341 4 138392703 [A/G] rs17049672 4 138393839 [A/G] rs2406613 4 138395132 [A/G] rs12643295 4 138395782 [A/C] rs10032588 4 138397770 [A/G] rs13112145 4 138413244 [T/C] rs9685021 4 138415363 [T/C] rs34680700 4 138433801 [T/C] rs9330352 4 138434955 [A/C] rs13108790 4 138436116 [A/G] rs9715105 4 138440012 [T/G] rs35678237 4 138449244 [T/C] NM_001300828,NM_019035 PCDH18,PCDH18 Silent,Silent rs13132611 4 138449411 [T/C] NM_001300828,NM_019035 PCDH18,PCDH18 Silent,Silent rs10018837 4 138449683 [A/G] NM_001300828,NM_019035 PCDH18,PCDH18 EXON Synonymous_L896L,Synonymous_L897L rs11939766 4 138454875 [A/G] rs28433055 4 138455637 [A/G] rs6841487 4 138459997 [A/C] rs9307912 4 138468166 [T/C] NR_146553 LINC02172 Silent rs6605362 4 138469564 [T/C] NR_146553 LINC02172 Silent rs10028163 4 138470185 [A/G] NR_146553 LINC02172 Silent rs6824771 4 138477450 [T/C] NR_146553 LINC02172 Silent rs9761983 4 138482973 [T/C] NR_146553 LINC02172 Silent rs4241943 4 138487777 [A/G] NR_146553 LINC02172 Silent rs4282237 4 138493361 [T/C] NR_146553 LINC02172 Silent rs10023753 4 138496793 [A/G] NR_146553 LINC02172 Silent rs4478233 4 138498854 [T/G] NR_146553 LINC02172 Silent rs6842329 4 138506420 [T/G] NR_146553 LINC02172 Silent rs4541566 4 138511228 [T/C] NR_146553 LINC02172 Silent rs4554127 4 138511495 [T/C] NR_146553 LINC02172 Silent rs4327536 4 138512291 [A/G] NR_146553 LINC02172 Silent rs3922840 4 138514969 [T/C] NR_146553 LINC02172 Silent rs4391086 4 138520936 [T/C] NR_146553 LINC02172 Silent rs4346697 4 138528410 [T/C] rs12645301 4 138534164 [A/C] rs10021969 4 138535434 [T/G] rs6841316 4 138541971 [A/G] rs9995514 4 138542282 [T/G] rs4863773 4 138544938 [T/C] rs2114927 4 138545488 [T/C] rs12500389 4 138558971 [A/G] rs11929785 4 138562836 [A/G] rs1110119 4 138563488 [A/C] rs4487406 4 138565294 [A/G] rs10019813 4 138567771 [A/G] rs13139417 4 138570928 [A/G] rs7666878 4 138571663 [A/C] rs17049735 4 138576003 [T/C] rs1976929 4 138577151 [A/G] rs6839772 4 138578594 [A/G] rs17049741 4 138582711 [A/G] rs11940418 4 138591227 [A/C] rs2434137 4 138593451 [T/C] rs2462870 4 138597155 [A/C] rs4618363 4 138598424 [A/G] rs2166356 4 138602702 [T/C] rs1949905 4 138603311 [T/C] rs1596795 4 138604190 [A/C] rs2559897 4 138609373 [T/G] rs3843891 4 138609462 [A/C] rs2693550 4 138611802 [A/G] rs11737372 4 138611810 [A/G] rs11946875 4 138616339 [A/G] rs17049806 4 138633459 [T/C] rs1526237 4 138633828 [A/G] rs13132522 4 138636149 [T/C] rs1526242 4 138644879 [T/C] rs17049850 4 138663042 [A/G] rs13142558 4 138663262 [T/C] rs1880774 4 138664579 [A/G] rs11941963 4 138666945 [T/C] rs17049861 4 138674263 [T/C] rs12374402 4 138678024 [T/C] rs10049648 4 138680839 [A/G] rs11930952 4 138683502 [T/C] rs10006087 4 138687290 [T/C] rs9308023 4 138688076 [T/C] rs2313132 4 138692250 [A/G] rs7681896 4 138694227 [T/C] rs7672176 4 138694514 [A/C] rs2089615 4 138701890 [A/G] rs2175072 4 138702796 [T/C] rs1509268 4 138712304 [A/C] rs1027876 4 138714027 [A/C] rs4863722 4 138726604 [A/G] rs11940232 4 138733886 [T/C] rs13132156 4 138739406 [A/G] rs6847679 4 138762626 [T/C] rs6815259 4 138763411 [A/C] rs6823023 4 138764286 [T/C] rs11930640 4 138783682 [T/C] rs2313982 4 138788060 [A/G] rs7679412 4 138794021 [T/C] rs12501677 4 138796386 [T/G] rs11935362 4 138797567 [A/G] rs17294252 4 138801097 [A/C] rs12511738 4 138801711 [A/G] rs6855385 4 138802565 [A/G] rs12503655 4 138803834 [A/G] rs1605819 4 138804645 [A/C] rs16998376 4 138810885 [T/C] rs13117595 4 138825270 [A/G] rs17049964 4 138828687 [A/G] rs1509255 4 138829787 [T/C] rs1960161 4 138831486 [T/C] rs13128867 4 138840995 [T/C] rs1519324 4 138852972 [T/G] rs4640713 4 138853076 [T/G] rs1589210 4 138862113 [T/G] rs6851757 4 138873552 [T/C] rs10023662 4 138876378 [T/C] rs7667668 4 138877026 [T/C] rs17231411 4 138881933 [T/G] rs2139320 4 138895657 [A/G] rs938025 4 138898310 [A/G] rs13131913 4 138900717 [A/G] rs6825001 4 138902871 [A/G] rs17050094 4 138912911 [A/G] rs4863533 4 138913554 [A/G] rs2056275 4 138939662 [T/C] rs7699316 4 138943184 [A/G] rs6834471 4 138954084 [T/C] NR_037866 LINC00616 Silent rs1807894 4 138956770 [A/C] NR_037866 LINC00616 Silent rs1607529 4 138959728 [A/G] NR_037866 LINC00616 Silent rs4863537 4 138965242 [T/C] NR_037866 LINC00616 Silent rs9284677 4 138976805 [A/G] NR_037866 LINC00616 Silent rs1439502 4 138977173 [T/C] NR_037866 LINC00616 Silent rs6842285 4 138983809 [A/G] NR_037866 LINC00616 Silent rs11734678 4 139005538 [T/G] NR_037866 LINC00616 Silent rs11100776 4 139014474 [T/C] NR_037866,NR_038380 LINC00616,SLC7A11-AS1 Silent,Silent rs1982203 4 139019356 [T/C] NR_037866,NR_038380 LINC00616,SLC7A11-AS1 EXON Silent,Silent rs2313455 4 139035912 [T/C] NR_037866,NR_038380 LINC00616,SLC7A11-AS1 Silent,Silent rs1344976 4 139064115 [A/G] NR_038380 SLC7A11-AS1 Silent rs4863764 4 139070297 [T/C] NR_038380 SLC7A11-AS1 Silent rs4863765 4 139079966 [A/C] NR_038380 SLC7A11-AS1 Silent rs11942121 4 139084238 [A/G] NR_038380 SLC7A11-AS1 Silent rs7688870 4 139084657 [A/C] NR_038380 SLC7A11-AS1 Silent rs7674870 4 139089463 [A/G] NR_038380,NM_014331 SLC7A11-AS1,SLC7A11 EXON Silent,Silent rs13144383 4 139090804 [A/G] NR_038380,NM_014331 SLC7A11-AS1,SLC7A11 EXON Silent,Silent rs10011428 4 139096721 [A/G] NR_038380,NM_014331 SLC7A11-AS1,SLC7A11 Silent,Silent rs4479754 4 139100372 [T/C] NM_014331 SLC7A11 Silent rs10016559 4 139103366 [A/G] NM_014331 SLC7A11 Silent rs6537201 4 139110577 [A/G] NM_014331 SLC7A11 Silent rs6852562 4 139112622 [A/G] NM_014331 SLC7A11 Silent rs4863771 4 139113336 [T/G] NM_014331 SLC7A11 Silent rs4863772 4 139120683 [T/C] NM_014331 SLC7A11 Silent rs4131888 4 139123748 [T/C] NM_014331 SLC7A11 Silent rs4602539 4 139125041 [T/G] NM_014331 SLC7A11 Silent rs6838248 4 139140494 [C/G] NM_014331 SLC7A11 EXON Synonymous_A224A rs4461565 4 139144689 [A/G] NM_014331 SLC7A11 Silent rs7666936 4 139150283 [T/C] NM_014331 SLC7A11 Silent rs2037027 4 139150889 [A/G] NM_014331 SLC7A11 Silent rs7685529 4 139155804 [T/C] NM_014331 SLC7A11 Silent rs11723658 4 139157996 [A/C] NM_014331 SLC7A11 Silent rs10007843 4 139159692 [T/C] NM_014331 SLC7A11 Silent rs13137929 4 139161014 [T/C] NM_014331 SLC7A11 Silent rs6537290 4 139175695 [A/G] rs11737641 4 139178894 [T/C] rs6816398 4 139179074 [T/C] rs17300990 4 139183123 [A/G] rs6850624 4 139184664 [T/C] rs2203291 4 139184781 [T/C] rs7687419 4 139185003 [A/G] rs11726463 4 139188359 [T/C] rs7657480 4 139192424 [A/G] rs1513765 4 139193151 [T/G] rs9308184 4 139194027 [T/C] rs4241941 4 139195152 [A/G] rs10021045 4 139203950 [T/C] rs6817763 4 139209701 [T/G] rs13119725 4 139211038 [T/G] rs4441808 4 139212420 [T/C] rs10519453 4 139212919 [T/C] rs17050247 4 139219080 [A/G] rs6537323 4 139223367 [T/C] rs7657780 4 139229237 [T/G] rs17050280 4 139232229 [A/G] NR_051987 LINC00499 Silent rs13120633 4 139234254 [T/G] NR_051987 LINC00499 Silent rs6810458 4 139238565 [T/G] NR_051987 LINC00499 Silent rs7670671 4 139243656 [T/C] NR_051987 LINC00499 Silent rs9991384 4 139244428 [T/G] NR_051987 LINC00499 Silent rs6849956 4 139249761 [A/G] NR_051987 LINC00499 Silent rs7669522 4 139253392 [T/C] NR_051987 LINC00499 Silent rs7669668 4 139253454 [T/C] NR_051987 LINC00499 Silent rs298482 4 139256033 [T/C] NR_051987 LINC00499 Silent rs13110033 4 139256359 [A/C] NR_051987 LINC00499 Silent rs11100890 4 139256474 [A/C] NR_051987 LINC00499 Silent rs7682572 4 139258276 [T/C] NR_051987 LINC00499 Silent rs3096659 4 139260411 [A/G] NR_051987 LINC00499 Silent rs298467 4 139262538 [A/C] NR_051987 LINC00499 Silent rs298469 4 139266486 [A/G] NR_051987 LINC00499 Silent rs298472 4 139267650 [T/C] NR_051987 LINC00499 Silent rs7687008 4 139268507 [T/C] NR_051987 LINC00499 Silent rs12509850 4 139271008 [A/G] NR_051987 LINC00499 Silent rs7657271 4 139271665 [A/C] NR_051987 LINC00499 Silent rs448469 4 139274999 [T/C] NR_051987 LINC00499 Silent rs1426532 4 139275208 [A/C] NR_051987 LINC00499 Silent rs417342 4 139282314 [A/G] NR_051987 LINC00499 Silent rs17531534 4 139285096 [T/C] NR_051987 LINC00499 Silent rs17050321 4 139285676 [T/G] NR_051987 LINC00499 Silent rs426029 4 139285764 [A/G] NR_051987 LINC00499 Silent rs11944210 4 139286917 [T/G] NR_051987 LINC00499 Silent rs17242939 4 139291850 [T/G] NR_051987 LINC00499 Silent rs1398925 4 139300684 [T/C] NR_051987 LINC00499 Silent rs6837219 4 139300738 [T/C] NR_051987 LINC00499 Silent rs10020766 4 139301684 [T/C] NR_051987 LINC00499 Silent rs12505439 4 139301744 [A/G] NR_051987 LINC00499 Silent rs298462 4 139302720 [A/G] NR_051987 LINC00499 Silent rs298461 4 139302835 [A/G] NR_051987 LINC00499 Silent rs7678098 4 139302875 [T/C] NR_051987 LINC00499 Silent rs6537378 4 139303058 [T/C] NR_051987 LINC00499 Silent rs6842871 4 139304119 [A/C] NR_051987 LINC00499 Silent rs11935389 4 139304278 [A/G] NR_051987 LINC00499 Silent rs13108768 4 139305143 [T/C] NR_051987 LINC00499 Silent rs12506913 4 139305156 [T/C] NR_051987 LINC00499 Silent rs2052750 4 139305290 [A/G] NR_051987 LINC00499 Silent rs6857347 4 139308745 [A/G] NR_051987 LINC00499 Silent rs7356153 4 139312114 [T/C] NR_051987 LINC00499 Silent rs6848489 4 139312812 [A/G] NR_051987 LINC00499 Silent rs10024841 4 139313266 [A/C] NR_051987 LINC00499 Silent rs6825410 4 139324474 [A/G] NR_051987 LINC00499 Silent rs17050362 4 139325031 [T/C] NR_051987 LINC00499 Silent rs1544891 4 139326271 [T/G] NR_051987 LINC00499 Silent rs4863797 4 139327019 [A/G] NR_051987 LINC00499 Silent rs2314413 4 139331299 [T/C] NR_051987 LINC00499 Silent rs6816442 4 139335602 [A/G] NR_051987 LINC00499 Silent rs17050379 4 139336503 [T/C] NR_051987 LINC00499 Silent rs2976499 4 139336708 [T/C] NR_051987 LINC00499 Silent rs11732157 4 139336851 [T/C] NR_051987 LINC00499 Silent rs17050391 4 139342080 [T/C] NR_051987 LINC00499 Silent rs2912467 4 139345618 [A/G] rs4270620 4 139349170 [T/C] rs17050398 4 139350368 [A/G] rs2912470 4 139361172 [T/C] rs10519466 4 139366615 [T/C] rs2976490 4 139367276 [T/C] rs17245609 4 139367951 [A/G] rs971950 4 139376233 [A/G] rs1426520 4 139376425 [T/C] rs1834624 4 139377761 [T/G] rs2912475 4 139379432 [A/G] rs755954 4 139387054 [A/G] rs1346214 4 139387890 [T/C] rs6818743 4 139388475 [A/G] rs2912473 4 139391659 [T/G] rs9308208 4 139396007 [T/C] rs13148881 4 139396693 [T/C] rs2976477 4 139398829 [A/G] rs13108353 4 139399972 [T/C] rs17306061 4 139403208 [A/G] rs17050442 4 139403484 [A/G] rs12644806 4 139406421 [A/G] rs10519463 4 139407719 [T/C] rs10018963 4 139409081 [A/G] rs17306529 4 139409291 [T/G] rs299113 4 139431355 [T/C] rs299120 4 139434076 [T/C] rs1450432 4 139443162 [T/C] rs13146205 4 139457814 [A/G] rs299159 4 139459433 [A/C] rs299160 4 139460404 [T/C] rs2060673 4 139460443 [T/G] rs17050484 4 139462440 [T/C] rs13135708 4 139464920 [A/G] rs6853222 4 139476568 [A/C] rs11730882 4 139482703 [A/G] rs7694744 4 139482958 [T/G] rs1376082 4 139485229 [A/G] rs1530798 4 139486064 [T/C] rs6831698 4 139486920 [T/G] rs1817031 4 139488136 [T/C] rs1450439 4 139493398 [A/G] rs1376086 4 139494811 [A/G] rs1376088 4 139495121 [A/G] rs13142307 4 139495763 [A/G] rs1376091 4 139496147 [A/G] rs7435327 4 139497265 [A/G] rs13131639 4 139500215 [T/C] rs12643388 4 139503481 [A/G] rs6841254 4 139506065 [T/G] rs12504508 4 139507392 [T/G] rs12644755 4 139507777 [T/C] rs12648634 4 139509925 [T/G] rs9307846 4 139510249 [T/C] rs9685123 4 139513580 [A/G] rs4863565 4 139514099 [A/C] rs1450453 4 139519532 [A/G] rs17050529 4 139528388 [A/C] rs7679163 4 139530255 [A/G] rs7680585 4 139530310 [A/C] rs12639806 4 139532860 [A/G] rs13435856 4 139535299 [T/C] rs2198030 4 139537855 [T/C] rs975477 4 139539662 [T/C] rs6851978 4 139540219 [T/C] rs12233744 4 139541397 [T/C] rs11941340 4 139550075 [A/C] rs719922 4 139552686 [A/C] rs1450454 4 139555962 [T/C] rs4863572 4 139557368 [A/G] rs11721545 4 139567521 [A/C] rs12502933 4 139568754 [A/G] rs4863578 4 139570038 [A/G] rs6535613 4 139571883 [T/C] rs6811051 4 139573376 [T/C] rs1450449 4 139574585 [T/C] rs12504582 4 139575076 [A/G] rs12501198 4 139575494 [A/G] rs10017576 4 139580179 [T/C] rs2122509 4 139580945 [A/C] rs9685238 4 139581543 [T/C] rs13135384 4 139582664 [A/G] rs6835813 4 139584101 [A/G] rs12501270 4 139584504 [A/C] rs7692637 4 139590199 [T/G] rs4863585 4 139605165 [A/C] rs10004565 4 139605950 [T/C] rs17050584 4 139608671 [T/C] rs7685323 4 139609402 [A/G] rs1505862 4 139611388 [T/C] rs4863587 4 139611745 [T/G] rs13105973 4 139612339 [A/G] rs7693492 4 139612743 [T/C] rs7667792 4 139624155 [T/C] rs9790693 4 139626820 [T/C] rs7655082 4 139629908 [A/G] rs905998 4 139631377 [T/C] rs4863590 4 139636653 [T/C] rs6851223 4 139637374 [A/G] rs2135287 4 139646534 [T/C] rs6824816 4 139648420 [T/C] rs6853043 4 139651607 [A/G] rs6812423 4 139653067 [A/G] rs1505866 4 139655744 [A/G] rs1505867 4 139655759 [T/C] rs6821816 4 139658216 [T/C] rs11945056 4 139665163 [A/C] rs17050617 4 139686911 [A/G] rs10020229 4 139687856 [A/G] rs7686170 4 139690422 [A/G] rs11099746 4 139692069 [T/G] rs1540744 4 139692813 [A/G] rs6535696 4 139695631 [A/G] rs11736543 4 139696731 [A/G] rs6855592 4 139698522 [T/G] rs9996437 4 139708493 [T/C] rs1948898 4 139710480 [A/G] rs9307869 4 139711242 [T/C] rs13136052 4 139711726 [T/G] rs1505869 4 139716412 [A/G] rs1995598 4 139717020 [T/G] rs6812265 4 139726791 [T/C] rs6844434 4 139727944 [A/C] rs7657235 4 139729522 [T/C] rs6535707 4 139729690 [A/C] rs1505864 4 139731065 [T/C] rs13118554 4 139734961 [A/C] rs11728868 4 139739456 [A/G] rs870076 4 139740935 [A/T] rs2102309 4 139745929 [A/G] NR_133945 LOC105377448 Silent rs4481278 4 139748640 [T/C] NR_133945 LOC105377448 Silent rs10006363 4 139753601 [A/G] NR_133945 LOC105377448 Silent rs10022416 4 139755093 [A/G] NR_133945 LOC105377448 Silent rs6854489 4 139764049 [T/C] NR_133945 LOC105377448 Silent rs17050640 4 139768109 [T/C] NR_133945 LOC105377448 Silent rs10001269 4 139771078 [A/G] NR_133945 LOC105377448 Silent rs2135289 4 139771441 [A/G] NR_133945 LOC105377448 Silent rs7669416 4 139773223 [A/G] NR_133945 LOC105377448 Silent rs11728621 4 139779568 [A/G] NR_133945 LOC105377448 Silent rs6844950 4 139789454 [A/G] NR_133945 LOC105377448 Silent rs7689448 4 139790626 [T/G] NR_133945 LOC105377448 Silent rs4074855 4 139794345 [T/G] NR_133945 LOC105377448 Silent rs4074856 4 139794516 [A/G] NR_133945 LOC105377448 Silent rs6535748 4 139799012 [T/C] NR_133945 LOC105377448 Silent rs7684118 4 139814341 [T/C] NR_133945 LOC105377448 Silent rs4639023 4 139826720 [A/G] NR_133945 LOC105377448 Silent rs13103414 4 139833891 [A/G] NR_133945 LOC105377448 Silent rs6823019 4 139836353 [T/C] NR_133945 LOC105377448 Silent rs10004074 4 139837873 [A/G] NR_133945 LOC105377448 Silent rs13146053 4 139839354 [A/G] NR_133945 LOC105377448 Silent rs4241923 4 139842608 [T/C] NR_133945 LOC105377448 Silent rs6535770 4 139844426 [T/C] NR_133945 LOC105377448 Silent rs10028549 4 139847316 [T/G] NR_133945 LOC105377448 Silent rs6858505 4 139848044 [A/C] NR_133945 LOC105377448 Silent rs6839690 4 139856728 [T/G] NR_133945 LOC105377448 Silent rs6848189 4 139860920 [T/G] NR_133945 LOC105377448 Silent rs9790390 4 139861084 [A/G] NR_133945 LOC105377448 Silent rs7697018 4 139861368 [T/C] NR_133945 LOC105377448 Silent rs11731798 4 139861418 [T/C] NR_133945 LOC105377448 Silent rs4863620 4 139876605 [A/G] NR_133945 LOC105377448 Silent rs11723586 4 139884321 [T/C] NR_133945 LOC105377448 Silent rs6858120 4 139899443 [T/C] NR_133945 LOC105377448 Silent rs7659060 4 139906122 [T/C] NR_133945 LOC105377448 Silent rs13101244 4 139907427 [T/G] NR_133945 LOC105377448 Silent rs4309784 4 139908503 [A/G] NR_133945 LOC105377448 Silent rs6817458 4 139915883 [T/C] NR_133945 LOC105377448 Silent rs6848587 4 139925351 [T/C] NR_133945 LOC105377448 Silent rs13116075 4 139930032 [A/G] NR_133945 LOC105377448 Silent rs11734536 4 139949447 [T/C] NM_012118 NOCT Silent rs10212985 4 139953522 [T/G] NM_012118 NOCT Silent rs13108158 4 139956166 [T/C] NM_012118 NOCT Silent rs1112828 4 139956970 [T/G] NM_012118 NOCT Silent rs11723089 4 139961692 [A/G] NM_012118 NOCT Silent rs2271777 4 139964455 [T/C] NM_012118 NOCT EXON Missense_H140Y rs6841713 4 139975818 [A/G] rs3796637 4 139981918 [T/G] NM_001331036,NM_201999,NM_001276458,NM_001276457,NM_006874,NM_001276459 ELF2,ELF2,ELF2,ELF2,ELF2,ELF2 Silent,Silent,Silent,Silent,Silent,Silent rs10006722 4 139983659 [T/C] NM_001331036,NM_201999,NM_001276458,NM_001276457,NM_006874,NM_001276459 ELF2,ELF2,ELF2,ELF2,ELF2,ELF2 Silent,Silent,Silent,Silent,Silent,Silent rs17322140 4 139993175 [A/G] NM_001331036,NM_201999,NM_001276458,NM_001276457,NM_006874,NM_001276459 ELF2,ELF2,ELF2,ELF2,ELF2,ELF2 EXON Missense_P124L,Silent,Silent,Missense_P64L,Missense_P64L,Silent rs10776526 4 139998918 [A/C] NM_001331036,NM_201999,NM_001276458,NM_001276457,NM_006874,NM_001276459 ELF2,ELF2,ELF2,ELF2,ELF2,ELF2 Silent,Silent,Silent,Silent,Silent,Silent rs4863628 4 140005294 [A/G] NM_001331036,NM_201999,NM_001276458,NM_001276457,NM_006874,NM_001276459 ELF2,ELF2,ELF2,ELF2,ELF2,ELF2 EXON Silent,Silent,Synonymous_I17I,Synonymous_I17I,Synonymous_I17I,Synonymous_I17I rs2292837 4 140006680 [T/G] NM_001331036,NM_201999 ELF2,ELF2 Silent,Silent rs11725721 4 140046907 [T/C] NM_001331036,NM_201999 ELF2,ELF2 Silent,Silent rs1074868 4 140064396 [T/C] NM_001331036 ELF2 Silent rs13134328 4 140065768 [T/C] NM_001331036 ELF2 Silent rs2046661 4 140075052 [A/G] NM_001331036 ELF2 Silent rs17050698 4 140077258 [T/C] NM_001331036 ELF2 Silent rs4597768 4 140093565 [T/C] NM_001331036 ELF2 Silent rs1471928 4 140099768 [T/C] rs4586876 4 140100756 [A/G] rs11941589 4 140115744 [A/G] rs4863634 4 140116032 [A/G] rs6825915 4 140117588 [T/C] rs9942285 4 140118204 [A/G] rs6842638 4 140121812 [A/G] rs12648234 4 140128447 [T/C] rs6820313 4 140134659 [T/G] rs17342946 4 140142754 [T/C] rs7660661 4 140151736 [T/C] rs13143516 4 140159339 [A/G] rs17050725 4 140165548 [T/C] rs4863639 4 140165770 [T/C] rs6835286 4 140166713 [T/C] rs6841480 4 140167394 [A/C] rs2029288 4 140170092 [A/C] rs17050728 4 140177399 [T/G] rs6536020 4 140177562 [T/G] rs13103115 4 140186178 [T/C] rs3208941 4 140188094 [T/C] NM_032623 MGARP EXON Missense_A128T rs13120574 4 140189613 [A/G] NM_032623 MGARP Silent rs13127307 4 140199813 [A/G] NM_032623 MGARP Silent rs17050736 4 140212370 [T/C] NM_001184989,NM_001184990,NM_001184991,NM_001184987,NM_001184986,NM_001184988,NM_002494 NDUFC1,NDUFC1,NDUFC1,NDUFC1,NDUFC1,NDUFC1,NDUFC1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12642647 4 140212927 [T/C] NM_001184989,NM_001184990,NM_001184991,NM_001184987,NM_001184986,NM_001184988,NM_002494 NDUFC1,NDUFC1,NDUFC1,NDUFC1,NDUFC1,NDUFC1,NDUFC1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6816703 4 140216412 [T/C] NM_001184989,NM_001184990,NM_001184991,NM_001184987,NM_001184986,NM_001184988,NM_002494 NDUFC1,NDUFC1,NDUFC1,NDUFC1,NDUFC1,NDUFC1,NDUFC1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10003164 4 140217636 [T/C] NM_001184989,NM_001184990,NM_001184991,NM_001184987,NM_001184986,NM_001184988,NM_002494 NDUFC1,NDUFC1,NDUFC1,NDUFC1,NDUFC1,NDUFC1,NDUFC1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11729130 4 140225539 [T/C] NM_057175 NAA15 Silent rs13147688 4 140228808 [A/G] NM_057175 NAA15 Silent rs10023356 4 140234360 [T/C] NM_057175 NAA15 Silent rs1901173 4 140235620 [A/G] NM_057175 NAA15 Silent rs12645529 4 140243755 [A/G] NM_057175 NAA15 Silent rs747004 4 140254518 [T/C] NM_057175 NAA15 Silent rs17050742 4 140258872 [A/G] NM_057175 NAA15 Silent rs6820950 4 140259458 [T/C] NM_057175 NAA15 Silent rs13117654 4 140289285 [A/G] NM_057175 NAA15 Silent rs7687436 4 140330090 [A/G] rs12647302 4 140368070 [T/C] rs13128827 4 140370149 [A/G] rs1142627 4 140373081 [A/C] rs17050767 4 140373938 [T/G] rs4074940 4 140395583 [T/C] NM_031296 RAB33B EXON Silent rs3088313 4 140396931 [A/C] NM_031296 RAB33B EXON Silent rs11931237 4 140406214 [A/G] rs3967770 4 140406637 [A/C] rs7666900 4 140414333 [T/C] rs4863655 4 140417471 [T/G] NM_001306199 SETD7 EXON Silent rs2592966 4 140420250 [A/G] NM_001306199 SETD7 Silent rs17050782 4 140423134 [A/G] NM_001306199 SETD7 Silent rs720257 4 140425004 [A/G] NM_001306199 SETD7 Silent rs6821008 4 140426195 [T/G] NM_001306199 SETD7 Silent rs1026048 4 140429555 [T/C] NM_001306199,NM_030648 SETD7,SETD7 EXON Silent,Silent rs895600 4 140430625 [A/C] NM_001306199,NM_030648 SETD7,SETD7 EXON Silent,Silent rs17050790 4 140431931 [T/C] NM_001306199,NM_030648 SETD7,SETD7 EXON Silent,Silent rs2725773 4 140436646 [A/G] NM_001306199,NM_030648 SETD7,SETD7 Silent,Silent rs6841340 4 140438766 [A/G] NM_001306199,NM_030648 SETD7,SETD7 Silent,Silent rs2592980 4 140442145 [A/G] NM_001306199,NM_030648 SETD7,SETD7 Silent,Silent rs7680948 4 140447105 [A/C] NM_001306199,NM_030648 SETD7,SETD7 Silent,Silent rs2725779 4 140449420 [T/C] NM_001306199,NM_030648 SETD7,SETD7 Silent,Silent rs4863658 4 140449824 [T/C] NM_001306199,NM_030648 SETD7,SETD7 Silent,Silent rs10025309 4 140458672 [T/C] NM_001306199,NM_030648,NR_131339,NM_001306200 SETD7,SETD7,SETD7,SETD7 Silent,Silent,Silent,Silent rs2725790 4 140460303 [T/C] NM_001306199,NM_030648,NR_131339,NM_001306200 SETD7,SETD7,SETD7,SETD7 Silent,Silent,Silent,Silent rs1995103 4 140466311 [A/G] NM_001306199,NM_030648,NR_131339,NM_001306200 SETD7,SETD7,SETD7,SETD7 Silent,Silent,Silent,Silent rs6828434 4 140466604 [T/C] NM_001306199,NM_030648,NR_131339,NM_001306200 SETD7,SETD7,SETD7,SETD7 Silent,Silent,Silent,Silent rs2592984 4 140470212 [T/G] NM_001306199,NM_030648,NR_131339,NM_001306200 SETD7,SETD7,SETD7,SETD7 Silent,Silent,Silent,Silent rs706308 4 140476214 [T/G] NM_001306199,NM_030648,NR_131339,NM_001306200 SETD7,SETD7,SETD7,SETD7 Silent,Silent,Silent,Silent rs706309 4 140478478 [T/C] rs706310 4 140481510 [A/G] rs795617 4 140495051 [T/C] rs11726931 4 140497312 [T/C] rs2166596 4 140505632 [A/G] rs706328 4 140511212 [T/C] rs17282576 4 140513877 [A/G] rs706333 4 140517700 [T/C] rs7689415 4 140518308 [T/C] rs795377 4 140519467 [A/C] rs706336 4 140522504 [T/C] rs706337 4 140523889 [A/G] rs2602248 4 140528564 [A/G] rs13112005 4 140528612 [T/C] rs6536296 4 140531714 [T/G] rs13114510 4 140534118 [A/G] rs4627803 4 140536648 [A/G] rs2602234 4 140537127 [A/G] rs11936429 4 140537671 [T/C] rs13111220 4 140542332 [A/G] rs10027416 4 140542427 [A/G] rs17355469 4 140544895 [A/C] rs706341 4 140545348 [T/G] rs10018489 4 140546481 [A/C] rs17050838 4 140549569 [A/G] rs706345 4 140549622 [A/G] rs4241931 4 140552120 [T/C] rs1027472 4 140552399 [T/C] rs885156 4 140560388 [A/C] rs11100193 4 140563222 [T/G] rs10023253 4 140563620 [A/C] rs17050841 4 140568534 [T/C] rs1316503 4 140573599 [A/G] rs2602219 4 140575134 [A/G] rs2602218 4 140575501 [A/G] rs1078764 4 140576200 [T/C] rs7687822 4 140577717 [T/G] rs3755996 4 140577920 [A/C] rs3755995 4 140578013 [T/C] rs3755993 4 140578214 [A/G] rs17050847 4 140578500 [A/G] rs3755992 4 140579042 [A/G] rs924199 4 140579455 [T/C] rs12640152 4 140580748 [A/G] rs795602 4 140581932 [A/G] rs17050853 4 140584689 [A/G] rs8191997 4 140585031 [A/G] rs8191998 4 140585089 [T/C] rs8192002 4 140585750 [A/C] rs8192004 4 140586701 [A/C] rs2132845 4 140587125 [T/A] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 EXON Silent,Silent,Silent,Silent rs3822045 4 140587414 [A/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs4147586 4 140587442 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs8192010 4 140587955 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs1000222 4 140587985 [A/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs8192013 4 140588391 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs795594 4 140590595 [T/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs8192018 4 140590947 [A/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs8192024 4 140592641 [A/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs8192031 4 140593075 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs3822044 4 140593264 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs2602238 4 140593308 [A/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs2602239 4 140594551 [T/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs8192047 4 140596699 [A/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs8192049 4 140597052 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs1087784 4 140597670 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs8192060 4 140599053 [A/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs795590 4 140599973 [A/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs795589 4 140600125 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs706349 4 140600307 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs1027473 4 140600397 [A/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs706350 4 140600437 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs4241932 4 140601036 [A/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs1587265 4 140601791 [A/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs2262377 4 140601934 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs2132847 4 140602972 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs8192075 4 140605684 [T/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs7664138 4 140606425 [A/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs795593 4 140608002 [A/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs13124794 4 140608583 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs795592 4 140608645 [T/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs2602243 4 140612059 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs4147590 4 140614711 [A/G] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs8192098 4 140616417 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 EXON Silent,Synonymous_N75N,Synonymous_N75N,Synonymous_N7N rs8192100 4 140616983 [A/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs8192111 4 140624681 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 EXON Synonymous_C77C,Missense_A101V,Missense_A101V,Missense_A33V rs8192112 4 140625156 [T/C] NM_001204368,NM_001204366,NM_002413,NM_001204367 MGST2,MGST2,MGST2,MGST2 Silent,Silent,Silent,Silent rs345978 4 140626105 [A/G] NM_001204366,NM_001204367 MGST2,MGST2 Silent,Silent rs345976 4 140627667 [T/C] NM_001204366,NM_001204367 MGST2,MGST2 Silent,Silent rs17357657 4 140631359 [T/C] NM_001204366,NM_001204367 MGST2,MGST2 Silent,Silent rs11944843 4 140637703 [A/G] NM_001204366,NM_001204367 MGST2,MGST2 Silent,Silent rs13112141 4 140637815 [A/G] NM_001204366,NM_001204367 MGST2,MGST2 Silent,Silent rs345983 4 140638963 [T/C] NM_001204366,NM_001204367,NM_018717 MGST2,MGST2,MAML3 EXON Silent,Silent,Silent rs3822043 4 140640279 [T/C] NM_001204366,NM_001204367,NM_018717 MGST2,MGST2,MAML3 EXON Silent,Silent,Silent rs10519504 4 140640283 [T/G] NM_001204366,NM_001204367,NM_018717 MGST2,MGST2,MAML3 EXON Silent,Silent,Silent rs17050884 4 140642257 [A/G] NM_001204366,NM_001204367,NM_018717 MGST2,MGST2,MAML3 Silent,Silent,Silent rs180788 4 140642966 [A/G] NM_001204366,NM_001204367,NM_018717 MGST2,MGST2,MAML3 Silent,Silent,Silent rs4863507 4 140643322 [A/G] NM_001204366,NM_001204367,NM_018717 MGST2,MGST2,MAML3 Silent,Silent,Silent rs6835548 4 140644144 [T/C] NM_001204366,NM_001204367,NM_018717 MGST2,MGST2,MAML3 Silent,Silent,Silent rs2246759 4 140650730 [A/G] NM_001204366,NM_001204367,NM_018717 MGST2,MGST2,MAML3 Silent,Silent,Silent rs17050893 4 140650787 [T/C] NM_001204366,NM_001204367,NM_018717 MGST2,MGST2,MAML3 Silent,Silent,Silent rs17286383 4 140651229 [A/G] NM_001204366,NM_001204367,NM_018717 MGST2,MGST2,MAML3 Silent,Silent,Silent rs7674828 4 140663621 [T/G] NM_018717 MAML3 Silent rs7678266 4 140668374 [T/C] NM_018717 MAML3 Silent rs11100251 4 140669616 [T/C] NM_018717 MAML3 Silent rs12641953 4 140670043 [T/C] NM_018717 MAML3 Silent rs4863683 4 140676385 [T/C] NM_018717 MAML3 Silent rs6854360 4 140676411 [T/C] NM_018717 MAML3 Silent rs17050895 4 140677733 [T/G] NM_018717 MAML3 Silent rs4863687 4 140678281 [T/C] NM_018717 MAML3 Silent rs10857325 4 140679983 [A/G] NM_018717 MAML3 Silent rs4863510 4 140684195 [A/C] NM_018717 MAML3 Silent rs10021952 4 140684567 [A/G] NM_018717 MAML3 Silent rs907320 4 140686645 [T/C] NM_018717 MAML3 Silent rs4073315 4 140687323 [T/C] NM_018717 MAML3 Silent rs6835277 4 140693020 [A/C] NM_018717 MAML3 Silent rs6815550 4 140693868 [A/G] NM_018717 MAML3 Silent rs6816973 4 140693870 [T/C] NM_018717 MAML3 Silent rs11721831 4 140694305 [A/C] NM_018717 MAML3 Silent rs7690424 4 140694724 [A/G] NM_018717 MAML3 Silent rs6848976 4 140694991 [A/C] NM_018717 MAML3 Silent rs932012 4 140696130 [T/C] NM_018717 MAML3 Silent rs7679592 4 140696703 [T/C] NM_018717 MAML3 Silent rs11100269 4 140697617 [A/G] NM_018717 MAML3 Silent rs6839816 4 140702406 [A/G] NM_018717 MAML3 Silent rs6812244 4 140705510 [A/G] NM_018717 MAML3 Silent rs2175458 4 140709444 [A/G] NM_018717 MAML3 Silent rs6823459 4 140709905 [T/C] NM_018717 MAML3 Silent rs795998 4 140713471 [A/G] NM_018717 MAML3 Silent rs6849438 4 140721565 [T/G] NM_018717 MAML3 Silent rs2604931 4 140724600 [A/G] NM_018717 MAML3 Silent rs7670072 4 140728731 [A/G] NM_018717 MAML3 Silent rs795989 4 140729346 [A/G] NM_018717 MAML3 Silent rs795992 4 140736222 [A/G] NM_018717 MAML3 Silent rs1350038 4 140744599 [T/C] NM_018717 MAML3 Silent rs795988 4 140747153 [T/C] NM_018717 MAML3 Silent rs13112683 4 140749745 [T/G] NM_018717 MAML3 Silent rs6840907 4 140762420 [T/C] NM_018717 MAML3 Silent rs17050934 4 140765505 [T/C] NM_018717 MAML3 Silent rs11100308 4 140769923 [T/G] NM_018717 MAML3 Silent rs795971 4 140776128 [A/C] NM_018717 MAML3 Silent rs2667370 4 140778960 [T/C] NM_018717 MAML3 Silent rs2667364 4 140782082 [T/C] NM_018717 MAML3 Silent rs17367750 4 140782542 [T/C] NM_018717 MAML3 Silent rs11100314 4 140783603 [A/G] NM_018717 MAML3 Silent rs2320535 4 140793181 [T/G] NM_018717 MAML3 Silent rs1531070 4 140795327 [A/G] NM_018717 MAML3 Silent rs9999030 4 140801949 [A/G] NM_018717 MAML3 Silent rs795981 4 140802689 [T/C] NM_018717 MAML3 Silent rs17050970 4 140806021 [T/C] NM_018717 MAML3 Silent rs4863700 4 140808139 [A/C] NM_018717 MAML3 Silent rs6839194 4 140809656 [A/C] NM_018717 MAML3 Silent rs11729794 4 140810700 [T/C] NM_018717 MAML3 EXON Synonymous_P630P rs11726067 4 140812788 [T/C] NM_018717 MAML3 Silent rs12509463 4 140814922 [T/C] NM_018717 MAML3 Silent rs12505461 4 140815184 [T/C] NM_018717 MAML3 Silent rs17050982 4 140815925 [T/C] NM_018717 MAML3 Silent rs10026813 4 140816174 [A/G] NM_018717 MAML3 Silent rs7686178 4 140816317 [T/G] NM_018717 MAML3 Silent rs10029731 4 140816848 [T/C] NM_018717 MAML3 Silent rs9997981 4 140821391 [A/G] NM_018717 MAML3 Silent rs11724190 4 140823857 [T/G] NM_018717 MAML3 Silent rs11100354 4 140824428 [T/C] NM_018717 MAML3 Silent rs17051001 4 140825430 [T/C] NM_018717 MAML3 Silent rs17005223 4 140834736 [A/G] NM_018717 MAML3 Silent rs17370238 4 140835297 [A/G] NM_018717 MAML3 Silent rs1378473 4 140835853 [A/G] NM_018717 MAML3 Silent rs769654 4 140839169 [A/G] NM_018717 MAML3 Silent rs13127289 4 140849333 [T/G] NM_018717 MAML3 Silent rs769683 4 140851575 [T/C] NM_018717 MAML3 Silent rs769667 4 140861245 [A/G] NM_018717 MAML3 Silent rs4863708 4 140873893 [A/C] NM_018717 MAML3 Silent rs769673 4 140882750 [A/G] NM_018717 MAML3 Silent rs17313183 4 140887838 [T/C] NM_018717 MAML3 Silent rs13119079 4 140888081 [T/C] NM_018717 MAML3 Silent rs4863711 4 140891385 [T/C] NM_018717 MAML3 Silent rs17313646 4 140892233 [T/G] NM_018717 MAML3 Silent rs10519515 4 140901754 [A/C] NM_018717 MAML3 Silent rs10519516 4 140902053 [A/G] NM_018717 MAML3 Silent rs4863713 4 140907254 [T/C] NM_018717 MAML3 Silent rs12504594 4 140909793 [A/C] NM_018717 MAML3 Silent rs7656823 4 140919083 [A/G] NM_018717 MAML3 Silent rs4863719 4 140922635 [A/G] NM_018717 MAML3 Silent rs4863721 4 140924160 [A/G] NM_018717 MAML3 Silent rs2048382 4 140929111 [T/C] NM_018717 MAML3 Silent rs1521491 4 140939653 [T/C] NM_018717 MAML3 Silent rs6851797 4 140942859 [T/C] NM_018717 MAML3 Silent rs17314804 4 140946828 [T/C] NM_018717 MAML3 Silent rs6850591 4 140949552 [T/C] NM_018717 MAML3 Silent rs11100449 4 140952110 [A/G] NM_018717 MAML3 Silent rs17374508 4 140952449 [T/C] NM_018717 MAML3 Silent rs13116165 4 140954867 [A/G] NM_018717 MAML3 Silent rs6851301 4 140959594 [A/G] NM_018717 MAML3 Silent rs17374883 4 140960502 [T/C] NM_018717 MAML3 Silent rs17315705 4 140961792 [A/G] NM_018717 MAML3 Silent rs9917854 4 140962132 [A/G] NM_018717 MAML3 Silent rs6828897 4 140968980 [A/G] NM_018717 MAML3 Silent rs1474246 4 140975013 [T/C] NM_018717 MAML3 Silent rs10519522 4 140981966 [T/C] NM_018717 MAML3 Silent rs10440457 4 140983576 [T/C] NM_018717 MAML3 Silent rs1402669 4 140985905 [T/C] NM_018717 MAML3 Silent rs11100475 4 140996427 [T/C] NM_018717 MAML3 Silent rs10017961 4 141000337 [A/G] NM_018717 MAML3 Silent rs12648900 4 141009952 [T/C] NM_018717 MAML3 Silent rs7691693 4 141012918 [T/C] NM_018717 MAML3 Silent rs6817684 4 141019884 [A/G] NM_018717 MAML3 Silent rs1546716 4 141029512 [A/G] NM_018717 MAML3 Silent rs6820015 4 141030652 [T/G] NM_018717 MAML3 Silent rs11100496 4 141035847 [A/G] NM_018717 MAML3 Silent rs2139926 4 141035921 [A/G] NM_018717 MAML3 Silent rs1464435 4 141048606 [A/G] NM_018717 MAML3 Silent rs1464434 4 141049040 [T/C] NM_018717 MAML3 Silent rs2280500 4 141053044 [T/C] NM_018717,NR_147610 MAML3,LOC101927516 Silent,Silent rs6858531 4 141053848 [T/C] NM_018717,NR_147610 MAML3,LOC101927516 Silent,Silent rs6822207 4 141055896 [A/G] NM_018717,NR_147610 MAML3,LOC101927516 EXON Silent,Silent rs17005563 4 141062860 [A/C] NM_018717 MAML3 Silent rs13112302 4 141062977 [T/C] NM_018717 MAML3 Silent rs1521496 4 141069147 [T/G] NM_018717 MAML3 Silent rs6536733 4 141069646 [T/C] NM_018717 MAML3 Silent rs17005617 4 141109029 [T/C] rs17005618 4 141111464 [T/G] rs13102559 4 141112167 [T/C] rs7665091 4 141117199 [A/C] rs6852648 4 141126409 [A/G] rs6816957 4 141150013 [T/C] rs17005641 4 141152657 [T/C] rs11733305 4 141155942 [T/G] rs7659292 4 141172413 [T/C] rs987218 4 141178328 [T/G] rs1398186 4 141181146 [T/C] NM_032547 SCOC Silent rs12502106 4 141183514 [A/C] NM_032547 SCOC Silent rs6831812 4 141194324 [A/G] NM_032547 SCOC Silent rs17005684 4 141205306 [T/C] NM_032547,NR_033939 SCOC,SCOC-AS1 EXON Silent,Silent rs7684736 4 141208028 [A/G] NM_032547,NR_033939 SCOC,SCOC-AS1 Silent,Silent rs10016497 4 141214222 [A/G] NM_032547,NR_033939 SCOC,SCOC-AS1 Silent,Silent rs7675351 4 141218757 [A/C] NM_032547,NR_033939 SCOC,SCOC-AS1 Silent,Silent rs868653 4 141219784 [A/G] NM_032547,NR_033939 SCOC,SCOC-AS1 Silent,Silent rs1877410 4 141227577 [T/C] NM_032547,NR_033939 SCOC,SCOC-AS1 Silent,Silent rs17005729 4 141231258 [T/C] NM_032547,NR_033939 SCOC,SCOC-AS1 Silent,Silent rs13128278 4 141234930 [A/C] NM_032547,NR_033939 SCOC,SCOC-AS1 Silent,Silent rs4956333 4 141236020 [T/C] NM_032547,NR_033939 SCOC,SCOC-AS1 Silent,Silent rs7678137 4 141237134 [A/G] NM_032547,NR_033939 SCOC,SCOC-AS1 Silent,Silent rs2137267 4 141246800 [T/C] NM_032547,NR_033939 SCOC,SCOC-AS1 Silent,Silent rs11100615 4 141249813 [A/G] NM_032547,NR_033939 SCOC,SCOC-AS1 Silent,Silent rs2874445 4 141253396 [T/G] NM_032547,NR_033939 SCOC,SCOC-AS1 Silent,Silent rs1039987 4 141262661 [T/C] NM_032547,NR_033939 SCOC,SCOC-AS1 Silent,Silent rs1039988 4 141262836 [A/G] NM_032547,NR_033939 SCOC,SCOC-AS1 Silent,Silent rs996116 4 141265134 [T/C] NM_032547,NR_033939,NM_001153635,NM_001153446,NM_001153690,NM_001153585 SCOC,SCOC-AS1,SCOC,SCOC,SCOC,SCOC Silent,Silent,Silent,Silent,Silent,Silent rs11945466 4 141267864 [T/C] NM_032547,NR_033939,NM_001153635,NM_001153446,NM_001153690,NM_001153585 SCOC,SCOC-AS1,SCOC,SCOC,SCOC,SCOC Silent,Silent,Silent,Silent,Silent,Silent rs10009892 4 141276725 [T/C] NM_032547,NR_033939,NM_001153635,NM_001153446,NM_001153690,NM_001153585 SCOC,SCOC-AS1,SCOC,SCOC,SCOC,SCOC Silent,Silent,Silent,Silent,Silent,Silent rs4956366 4 141284111 [T/C] NM_032547,NR_033939,NM_001153635,NM_001153446,NM_001153690,NM_001153585 SCOC,SCOC-AS1,SCOC,SCOC,SCOC,SCOC Silent,Silent,Silent,Silent,Silent,Silent rs7663838 4 141284198 [T/C] NM_032547,NR_033939,NM_001153635,NM_001153446,NM_001153690,NM_001153585 SCOC,SCOC-AS1,SCOC,SCOC,SCOC,SCOC Silent,Silent,Silent,Silent,Silent,Silent rs10024214 4 141286226 [T/C] NM_032547,NR_033939,NM_001153635,NM_001153446,NM_001153690,NM_001153585 SCOC,SCOC-AS1,SCOC,SCOC,SCOC,SCOC Silent,Silent,Silent,Silent,Silent,Silent rs358308 4 141298142 [A/C] NM_032547,NM_001153635,NM_001153446,NM_001153690,NM_001153585,NM_001153663,NM_001153552,NM_001153484 SCOC,SCOC,SCOC,SCOC,SCOC,SCOC,SCOC,SCOC Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs358311 4 141298709 [A/G] NM_032547,NM_001153635,NM_001153446,NM_001153690,NM_001153585,NM_001153663,NM_001153552,NM_001153484 SCOC,SCOC,SCOC,SCOC,SCOC,SCOC,SCOC,SCOC Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4362897 4 141304666 [T/C] rs3805317 4 141310226 [T/G] NM_001130675,NM_004362 CLGN,CLGN EXON Silent,Silent rs2175562 4 141319793 [A/G] NM_001130675,NM_004362 CLGN,CLGN Silent,Silent rs2175563 4 141320021 [T/C] NM_001130675,NM_004362 CLGN,CLGN EXON Missense_V290I,Missense_V290I rs7681627 4 141322236 [T/C] NM_001130675,NM_004362 CLGN,CLGN Silent,Silent rs2567241 4 141323162 [A/C] NM_001130675,NM_004362 CLGN,CLGN EXON Missense_A160S,Missense_A160S rs17005845 4 141325738 [A/G] NM_001130675,NM_004362 CLGN,CLGN Silent,Silent rs10519554 4 141341312 [A/G] NM_001130675,NM_004362 CLGN,CLGN Silent,Silent rs10012138 4 141343133 [A/G] NM_001130675,NM_004362 CLGN,CLGN Silent,Silent rs1367705 4 141350602 [T/G] rs6536958 4 141357957 [A/G] rs2060074 4 141358232 [A/G] rs17005918 4 141364288 [T/C] rs6830503 4 141371764 [A/C] NM_001277353 MGAT4D Silent rs1897280 4 141372158 [T/C] NM_001277353 MGAT4D Silent rs6836265 4 141379314 [T/C] NM_001277353 MGAT4D Silent rs12509826 4 141381635 [T/C] NM_001277353 MGAT4D Silent rs1431346 4 141388317 [T/C] NM_001277353 MGAT4D Silent rs6818155 4 141391868 [T/G] NM_001277353 MGAT4D Silent rs2321267 4 141403999 [A/C] NM_001277353 MGAT4D Silent rs2874478 4 141404389 [A/G] NM_001277353 MGAT4D Silent rs10519560 4 141409324 [A/G] NM_001277353 MGAT4D Silent rs7670320 4 141410251 [T/C] NM_001277353 MGAT4D Silent rs17389716 4 141414355 [T/G] NM_001277353 MGAT4D Silent rs12508462 4 141416100 [A/G] NM_001277353 MGAT4D Silent rs2321270 4 141422317 [T/G] rs9790415 4 141428878 [A/G] rs1241046 4 141436854 [T/C] rs1123003 4 141438865 [T/C] rs11945078 4 141445816 [A/G] NM_153702 ELMOD2 Silent rs3104107 4 141449275 [T/C] NM_153702 ELMOD2 Silent rs17006095 4 141459925 [T/C] NM_153702 ELMOD2 Silent rs17006098 4 141460300 [T/C] NM_153702 ELMOD2 Silent rs2321272 4 141465244 [T/C] NM_153702 ELMOD2 Silent rs6818701 4 141468569 [T/C] NM_153702 ELMOD2 Silent rs6536991 4 141481581 [T/C] NM_021833 UCP1 Silent rs6822807 4 141487748 [T/C] NM_021833 UCP1 Silent rs1800661 4 141489987 [T/C] rs10011540 4 141489996 [T/G] rs2043125 4 141494104 [A/G] rs12645959 4 141496369 [T/G] rs11942464 4 141496486 [A/G] rs17006132 4 141499558 [T/C] rs3851422 4 141500395 [T/C] rs12650255 4 141501385 [T/G] rs12509905 4 141509633 [T/C] rs2195645 4 141513385 [T/G] rs12640614 4 141518965 [T/C] rs4956454 4 141520308 [T/C] rs4956323 4 141525704 [T/C] rs4956324 4 141533137 [T/C] rs12503379 4 141533832 [A/C] rs4956325 4 141537771 [A/G] rs9994536 4 141540637 [A/G] rs3816933 4 141548569 [T/C] NM_015130 TBC1D9 Silent rs2291711 4 141549393 [A/C] NM_015130 TBC1D9 Silent rs1430581 4 141551799 [A/G] NM_015130 TBC1D9 Silent rs4956327 4 141554145 [A/G] NM_015130 TBC1D9 Silent rs10002459 4 141554949 [A/G] NM_015130 TBC1D9 Silent rs6813507 4 141561353 [T/G] NM_015130 TBC1D9 Silent rs35060427 4 141562798 [T/G] NM_015130,NR_077215 TBC1D9,TNRC18P1 EXON Silent,Silent rs6537003 4 141563992 [T/G] NM_015130,NR_077215 TBC1D9,TNRC18P1 EXON Silent,Silent rs17392415 4 141569847 [T/C] NM_015130 TBC1D9 Silent rs1430580 4 141570672 [A/G] NM_015130 TBC1D9 Silent rs13109751 4 141573742 [A/G] NM_015130 TBC1D9 Silent rs4956471 4 141574613 [A/G] NM_015130 TBC1D9 Silent rs2163322 4 141576673 [A/G] NM_015130 TBC1D9 Silent rs7683748 4 141578155 [T/C] NM_015130 TBC1D9 Silent rs13118702 4 141578253 [T/C] NM_015130 TBC1D9 EXON Missense_E779K rs3886094 4 141580561 [T/C] NM_015130 TBC1D9 Silent rs12640364 4 141582368 [A/G] NM_015130 TBC1D9 Silent rs6845527 4 141589301 [A/G] NM_015130 TBC1D9 Silent rs12643256 4 141593715 [T/C] NM_015130 TBC1D9 Silent rs7688253 4 141596785 [T/G] NM_015130 TBC1D9 Silent rs1469539 4 141597913 [A/G] NM_015130 TBC1D9 Silent rs2303912 4 141598290 [A/G] NM_015130 TBC1D9 Silent rs4956329 4 141600320 [A/G] NM_015130 TBC1D9 EXON Synonymous_L209L rs6813209 4 141601420 [T/C] NM_015130 TBC1D9 Silent rs17006331 4 141601922 [T/C] NM_015130 TBC1D9 Silent rs11736541 4 141616979 [T/C] NM_015130 TBC1D9 Silent rs13149166 4 141620931 [T/C] NM_015130 TBC1D9 Silent rs11731292 4 141625217 [A/G] NM_015130 TBC1D9 Silent rs923307 4 141629176 [A/G] NM_015130 TBC1D9 Silent rs10009007 4 141629826 [T/C] NM_015130 TBC1D9 Silent rs10004266 4 141633234 [T/C] NM_015130 TBC1D9 Silent rs2306815 4 141637275 [T/C] NM_015130 TBC1D9 Silent rs901687 4 141639072 [T/C] NM_015130 TBC1D9 Silent rs17006401 4 141652922 [A/G] NM_015130 TBC1D9 Silent rs1532013 4 141656467 [A/G] NM_015130 TBC1D9 Silent rs4555724 4 141658697 [T/C] NM_015130 TBC1D9 Silent rs6843792 4 141682299 [A/G] rs12331218 4 141688766 [A/G] rs11930453 4 141710146 [A/C] rs9308131 4 141711248 [T/C] rs7663798 4 141715430 [A/G] rs6810701 4 141716419 [T/C] rs11727409 4 141720070 [A/C] rs2171412 4 141723577 [T/G] rs4956481 4 141751240 [A/G] rs9993702 4 141765064 [A/C] rs6836292 4 141770572 [T/C] rs11731148 4 141773937 [T/C] rs10020274 4 141775106 [A/G] rs7696023 4 141776759 [A/G] rs1155206 4 141777368 [T/G] rs1487565 4 141779593 [A/G] rs17421358 4 141783289 [T/C] rs3733478 4 141783627 [A/G] rs3733480 4 141783990 [T/C] rs7655676 4 141784596 [A/G] rs998013 4 141786545 [T/C] rs3796699 4 141787735 [A/G] NM_020724 RNF150 EXON Silent rs13435056 4 141793869 [A/G] NM_020724 RNF150 Silent rs11730663 4 141795525 [A/G] NM_020724 RNF150 Silent rs6829449 4 141804520 [T/C] NM_020724 RNF150 Silent rs10009123 4 141805557 [T/C] NM_020724 RNF150 Silent rs1863305 4 141812185 [A/G] NM_020724 RNF150 Silent rs1863307 4 141812645 [A/G] NM_020724 RNF150 Silent rs767761 4 141816657 [A/C] NM_020724 RNF150 Silent rs3844179 4 141820214 [A/G] NM_020724 RNF150 Silent rs1030356 4 141826780 [A/G] NM_020724 RNF150 Silent rs1863301 4 141831660 [T/C] NM_020724 RNF150 Silent rs874776 4 141833025 [A/G] NM_020724 RNF150 Silent rs874775 4 141833103 [T/C] NM_020724 RNF150 Silent rs1834382 4 141833535 [T/C] NM_020724 RNF150 Silent rs17338560 4 141834589 [T/C] NM_020724 RNF150 Silent rs6537018 4 141836576 [A/G] NM_020724 RNF150 Silent rs1425446 4 141845421 [A/G] NM_020724 RNF150 Silent rs13118519 4 141851355 [T/C] NM_020724 RNF150 Silent rs7658326 4 141853440 [A/G] NM_020724 RNF150 Silent rs6537023 4 141865303 [T/C] NM_020724 RNF150 Silent rs1001487 4 141868515 [T/C] NM_020724 RNF150 Silent rs4956494 4 141870648 [A/G] NM_020724 RNF150 Silent rs11724213 4 141872192 [T/C] NM_020724 RNF150 Silent rs2321689 4 141875683 [T/C] NM_020724 RNF150 Silent rs17424664 4 141877688 [T/G] NM_020724 RNF150 Silent rs7689080 4 141879419 [T/C] NM_020724 RNF150 Silent rs6814533 4 141880666 [T/G] NM_020724 RNF150 Silent rs13127505 4 141880770 [T/C] NM_020724 RNF150 Silent rs10003541 4 141881059 [T/G] NM_020724 RNF150 Silent rs1425443 4 141881246 [T/C] NM_020724 RNF150 Silent rs10013093 4 141882031 [T/C] NM_020724 RNF150 Silent rs11724521 4 141888451 [A/C] NM_020724 RNF150 Silent rs1364880 4 141890683 [A/C] NM_020724 RNF150 Silent rs1425431 4 141891566 [T/C] NM_020724 RNF150 Silent rs1364881 4 141896970 [T/C] NM_020724 RNF150 Silent rs6820265 4 141903402 [T/C] NM_020724 RNF150 Silent rs9884460 4 141905646 [T/C] NM_020724 RNF150 Silent rs1364883 4 141906235 [T/C] NM_020724 RNF150 Silent rs6537024 4 141907543 [A/G] NM_020724 RNF150 Silent rs11726692 4 141920037 [A/G] NM_020724 RNF150 Silent rs12643749 4 141929562 [T/C] NM_020724 RNF150 Silent rs7687054 4 141933097 [T/C] NM_020724 RNF150 Silent rs3851424 4 141937337 [T/C] NM_020724 RNF150 Silent rs4245936 4 141940074 [T/C] NM_020724 RNF150 Silent rs2059499 4 141942359 [A/G] NM_020724 RNF150 Silent rs17425634 4 141943052 [T/C] NM_020724 RNF150 Silent rs13151459 4 141945926 [A/G] NM_020724 RNF150 Silent rs1907159 4 141953830 [T/C] NM_020724 RNF150 Silent rs11100699 4 141957064 [A/C] NM_020724 RNF150 Silent rs9997698 4 141957740 [T/C] NM_020724 RNF150 Silent rs3851427 4 141959896 [A/G] NM_020724 RNF150 Silent rs9993321 4 141960841 [T/C] NM_020724 RNF150 Silent rs7687232 4 141963286 [T/C] NM_020724 RNF150 Silent rs9991795 4 141965158 [T/C] NM_020724 RNF150 Silent rs12505705 4 141968129 [A/G] NM_020724 RNF150 Silent rs1395664 4 141968349 [T/C] NM_020724 RNF150 Silent rs12650097 4 141970192 [A/G] NM_020724 RNF150 Silent rs13116646 4 141972002 [T/C] NM_020724 RNF150 Silent rs2042630 4 141975349 [T/G] NM_020724 RNF150 Silent rs3863129 4 141978179 [A/G] NM_020724 RNF150 Silent rs4956344 4 141980240 [A/G] NM_020724 RNF150 Silent rs4361465 4 141982395 [A/G] NM_020724 RNF150 Silent rs2321859 4 141995467 [A/G] NM_020724 RNF150 Silent rs3851432 4 141996416 [T/C] NM_020724 RNF150 Silent rs3851433 4 141999286 [T/C] NM_020724 RNF150 Silent rs6537029 4 142007952 [A/G] NM_020724 RNF150 Silent rs11100704 4 142009392 [A/G] NM_020724 RNF150 Silent rs6836603 4 142011361 [T/C] NM_020724 RNF150 Silent rs11734545 4 142011941 [T/C] NM_020724 RNF150 Silent rs10454797 4 142016173 [A/G] NM_020724 RNF150 Silent rs4956510 4 142018265 [T/C] NM_020724 RNF150 Silent rs1507179 4 142021835 [T/C] NM_020724 RNF150 Silent rs4629541 4 142024322 [T/G] NM_020724 RNF150 Silent rs6813119 4 142028072 [A/G] NM_020724 RNF150 Silent rs4956517 4 142043379 [T/C] NM_020724 RNF150 Silent rs6853785 4 142061946 [T/C] rs4956520 4 142066755 [A/G] rs241867 4 142068023 [T/C] rs4956349 4 142068473 [T/C] rs354936 4 142070069 [T/C] rs4956353 4 142081109 [A/C] rs7663005 4 142092124 [T/C] rs2572237 4 142095474 [A/C] rs10013072 4 142095690 [A/G] rs7666238 4 142095763 [A/G] rs3851435 4 142112913 [A/G] rs354929 4 142112989 [A/G] rs4526055 4 142117367 [T/C] rs1550057 4 142117424 [A/G] rs2117576 4 142119839 [A/G] rs6822047 4 142125380 [A/G] rs13105932 4 142129233 [A/G] rs13129840 4 142129314 [T/G] rs6837873 4 142137165 [T/C] rs17007008 4 142141504 [A/G] rs17007021 4 142143781 [A/G] NM_014487,NM_001292002 ZNF330,ZNF330 Silent,Silent rs3822128 4 142155214 [T/C] NM_014487,NM_001292002 ZNF330,ZNF330 EXON Silent,Silent rs10033681 4 142155407 [T/C] NM_014487,NM_001292002 ZNF330,ZNF330 EXON Silent,Silent rs3733484 4 142155518 [T/G] NM_014487,NM_001292002 ZNF330,ZNF330 EXON Silent,Silent rs1435127 4 142159511 [T/C] rs7672861 4 142165741 [T/C] rs6537038 4 142166712 [A/G] rs1012864 4 142168903 [A/C] rs10002917 4 142169704 [T/C] rs978157 4 142177058 [A/G] rs1304390 4 142187853 [T/C] rs354843 4 142188804 [T/C] rs6840028 4 142197917 [T/C] rs13102572 4 142198497 [T/C] rs3114024 4 142203334 [T/C] rs3098027 4 142204581 [T/C] rs354850 4 142212781 [T/C] rs6857575 4 142218748 [A/G] rs189564 4 142220324 [A/T] rs17007137 4 142224247 [A/G] rs6818727 4 142230739 [A/G] rs1369970 4 142246430 [A/G] NR_121625 LINC02432 Silent rs1946731 4 142247487 [A/C] NR_121625 LINC02432 Silent rs10002181 4 142250415 [A/G] NR_121625 LINC02432 Silent rs7663070 4 142255485 [A/G] rs10003789 4 142266475 [A/G] rs4956372 4 142268897 [A/G] rs746484 4 142275621 [T/C] rs893037 4 142280519 [T/C] rs6838972 4 142291367 [A/G] rs9884442 4 142291626 [T/C] rs6825690 4 142296923 [A/G] rs1561152 4 142322777 [T/C] rs17007248 4 142326350 [T/G] rs17007252 4 142328977 [A/G] rs10519598 4 142331044 [T/G] rs6828736 4 142331924 [T/C] rs1079115 4 142333286 [T/G] rs6831004 4 142336683 [A/G] rs10022169 4 142346719 [T/C] rs1057260 4 142352369 [A/C] rs10519597 4 142353425 [T/C] rs6828927 4 142354175 [T/C] rs17007266 4 142355535 [T/C] rs12510810 4 142376136 [A/G] rs2139994 4 142399645 [T/C] rs13140249 4 142419423 [A/G] rs6852582 4 142420702 [A/G] rs17007330 4 142423257 [A/G] rs7693458 4 142423973 [A/C] rs7698747 4 142424409 [A/C] rs12644130 4 142432407 [T/C] rs13132036 4 142466804 [T/C] rs6857587 4 142478548 [T/G] rs1879685 4 142484038 [T/C] rs2322183 4 142487363 [T/G] rs4371699 4 142501053 [A/C] rs7671019 4 142515516 [A/G] rs11942294 4 142517416 [A/G] rs6835391 4 142533402 [T/C] rs2139383 4 142545451 [T/C] rs35747974 4 142557069 [T/G] rs1519551 4 142570472 [A/G] NR_037840,NM_172175,NM_000585 IL15,IL15,IL15 Silent,Silent,Silent rs2322262 4 142575266 [A/G] NR_037840,NM_172175,NM_000585 IL15,IL15,IL15 Silent,Silent,Silent rs957077 4 142579816 [T/C] NR_037840,NM_172175,NM_000585 IL15,IL15,IL15 Silent,Silent,Silent rs12504148 4 142590103 [T/C] NR_037840,NM_172175,NM_000585 IL15,IL15,IL15 Silent,Silent,Silent rs12510514 4 142601496 [A/C] NR_037840,NM_172175,NM_000585 IL15,IL15,IL15 Silent,Silent,Silent rs17007565 4 142634711 [A/G] NR_037840,NM_172175,NM_000585 IL15,IL15,IL15 Silent,Silent,Silent rs1607595 4 142635648 [T/C] NR_037840,NM_172175,NM_000585 IL15,IL15,IL15 Silent,Silent,Silent rs2322301 4 142636313 [T/C] NR_037840,NM_172175,NM_000585 IL15,IL15,IL15 Silent,Silent,Silent rs10519610 4 142637101 [T/C] NR_037840,NM_172175,NM_000585 IL15,IL15,IL15 Silent,Silent,Silent rs6850492 4 142637305 [A/G] NR_037840,NM_172175,NM_000585 IL15,IL15,IL15 Silent,Silent,Silent rs3775597 4 142649655 [A/G] NR_037840,NM_172175,NM_000585 IL15,IL15,IL15 Silent,Silent,Silent rs13122930 4 142650413 [T/C] NR_037840,NM_172175,NM_000585 IL15,IL15,IL15 Silent,Silent,Silent rs10519612 4 142653701 [A/C] NR_037840,NM_172175,NM_000585 IL15,IL15,IL15 Silent,Silent,Silent rs10833 4 142654547 [T/C] NR_037840,NM_172175,NM_000585 IL15,IL15,IL15 EXON Silent,Silent,Silent rs1493025 4 142657057 [A/G] rs9990563 4 142675412 [T/C] rs10004459 4 142677084 [T/G] rs10519629 4 142682770 [T/C] rs9884645 4 142686873 [T/G] rs4956410 4 142687795 [A/G] rs4254850 4 142688390 [T/C] rs7663689 4 142688981 [T/C] rs1493015 4 142691963 [T/C] rs7680696 4 142696583 [A/C] rs9996010 4 142699341 [A/G] rs1389098 4 142705418 [A/G] rs1493023 4 142710442 [A/C] rs17701271 4 142711243 [A/C] rs6537072 4 142715747 [T/C] rs10013727 4 142715821 [A/G] rs1304684 4 142719886 [A/G] rs4956412 4 142723797 [T/C] rs12511035 4 142725468 [A/G] rs7691866 4 142728396 [A/G] rs10018731 4 142728951 [T/C] rs17015015 4 142729438 [A/G] rs11100727 4 142732365 [A/G] rs10033645 4 142732715 [A/G] rs4956305 4 142733937 [A/G] rs13147278 4 142744198 [T/C] rs12506931 4 142746336 [A/G] rs10009998 4 142762276 [T/G] rs2099884 4 142763570 [A/G] rs12502051 4 142785171 [A/G] rs17015119 4 142792211 [A/G] rs11944032 4 142797440 [T/C] rs12503750 4 142808503 [A/G] rs17015143 4 142811058 [T/C] rs1500840 4 142812073 [T/C] rs713281 4 142820445 [T/C] rs1392773 4 142833862 [A/G] rs9993798 4 142834152 [A/G] rs2133926 4 142836161 [A/G] rs11731062 4 142849228 [T/G] rs1392779 4 142853017 [A/G] rs6537091 4 142874553 [T/C] rs4455499 4 142880833 [A/G] rs1604236 4 142898552 [A/G] rs1995960 4 142916958 [A/G] rs1995959 4 142917074 [T/C] rs11736202 4 142944080 [T/C] rs336361 4 142945451 [T/C] NM_001101669,NM_003866 INPP4B,INPP4B EXON Silent,Silent rs34280694 4 142949864 [A/C] NM_001101669,NM_003866 INPP4B,INPP4B EXON Silent,Silent rs336355 4 142952946 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs4245935 4 142954285 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs336350 4 142955593 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs17015287 4 142958897 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2645810 4 142964158 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs3775605 4 142968081 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2667096 4 142969773 [T/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1511252 4 142974842 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2667100 4 142976073 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2645796 4 142976319 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs4956433 4 142984889 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs12501475 4 142994344 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs336309 4 143012748 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs336292 4 143013388 [T/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs6537101 4 143014164 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs336297 4 143014875 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs336304 4 143019415 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs17468315 4 143020388 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs978752 4 143045599 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs3775648 4 143049620 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs3775652 4 143049980 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs3775654 4 143050454 [T/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs3775658 4 143052584 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs336407 4 143054921 [T/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs336408 4 143055538 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs13148456 4 143064439 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs10519631 4 143066199 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs336391 4 143076406 [T/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs336394 4 143077401 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs11724936 4 143080615 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs17015612 4 143081958 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs336384 4 143089849 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1390993 4 143094698 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1219273 4 143096594 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2636683 4 143098083 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2055212 4 143105706 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs992257 4 143114548 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2130687 4 143115192 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs10452237 4 143132237 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2627804 4 143138844 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs13109869 4 143153264 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2627801 4 143156127 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2627813 4 143208349 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2200997 4 143211964 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2636632 4 143214649 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2172023 4 143217391 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs10002445 4 143220613 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs3822152 4 143224296 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs3775692 4 143224971 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs17015882 4 143226496 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1907108 4 143227742 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs3775696 4 143228914 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1907107 4 143229634 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2636638 4 143230028 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1872294 4 143232702 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2636670 4 143234593 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs10024947 4 143234663 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2636671 4 143234955 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs960678 4 143236158 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs17015920 4 143240651 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2635429 4 143243556 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs17015922 4 143246186 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs6844681 4 143247240 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2646091 4 143257940 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs7666932 4 143259305 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1908968 4 143268702 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs716762 4 143272497 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs931422 4 143283085 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs6857918 4 143284623 [T/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs10519644 4 143286268 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs11938760 4 143290199 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs4956319 4 143296489 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs17016027 4 143297732 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs6845221 4 143300013 [T/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1497389 4 143304592 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs11930321 4 143305002 [T/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1391097 4 143309895 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs10006795 4 143318673 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1982965 4 143324036 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1982966 4 143324094 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B EXON Synonymous_D123D,Synonymous_D123D,Synonymous_D123D rs1489577 4 143331154 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1497388 4 143339542 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs6820463 4 143343605 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs12499068 4 143343632 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1497391 4 143346040 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs979511 4 143360851 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1489581 4 143369780 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1391099 4 143373910 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1013397 4 143375877 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs11930849 4 143393572 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs3913163 4 143394613 [T/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs7695918 4 143397125 [T/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs976563 4 143412932 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1593360 4 143414537 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs17016248 4 143418354 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1425533 4 143421175 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1425531 4 143426031 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1364920 4 143437219 [T/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs7691439 4 143444109 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs975136 4 143450575 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs10857395 4 143452535 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs6835296 4 143455287 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1425520 4 143474601 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs6814775 4 143476181 [T/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1473222 4 143488095 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1425523 4 143493559 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1425526 4 143518336 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs6856817 4 143534216 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs7685002 4 143562086 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs13119090 4 143578523 [T/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs10012488 4 143593086 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs10018925 4 143595242 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs6537123 4 143607404 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs10020322 4 143608324 [T/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs13150837 4 143613959 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs12650777 4 143617099 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs11943397 4 143617304 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1373036 4 143625262 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs11942593 4 143626567 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs10009093 4 143629934 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs13115869 4 143633482 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs12644329 4 143634746 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs4690698 4 143639211 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs986081 4 143655174 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs17016749 4 143677136 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs17016755 4 143683303 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs17732348 4 143691110 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs12504681 4 143708921 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs12509337 4 143723381 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1014464 4 143735741 [A/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1992418 4 143737159 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs1444949 4 143747354 [T/C] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs7661683 4 143753450 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs17016828 4 143757682 [A/G] NM_001101669,NM_003866,NM_001331040 INPP4B,INPP4B,INPP4B Silent,Silent,Silent rs2218240 4 143772767 [A/C] rs6537129 4 143779613 [A/G] rs6852412 4 143795347 [A/G] rs2874907 4 143796487 [T/G] rs11724679 4 143800361 [A/G] rs1372241 4 143804147 [T/C] rs1441413 4 143823839 [A/G] rs11933657 4 143827182 [A/G] rs716878 4 143835306 [A/G] rs732601 4 143842458 [T/C] rs10007618 4 143857477 [T/C] rs6834860 4 143861293 [T/C] rs13115045 4 143866615 [A/G] rs1510136 4 143882545 [A/G] rs17678540 4 143899483 [A/C] rs17017089 4 143904995 [T/C] rs1588408 4 143907480 [A/G] rs6817062 4 143927609 [T/C] rs1104696 4 143936903 [A/G] rs13136216 4 143960787 [A/G] rs10001212 4 143971806 [A/G] rs4690760 4 143972745 [T/C] rs11100768 4 143981731 [A/G] rs13126430 4 143998282 [A/G] rs7686660 4 144003159 [T/G] rs10032938 4 144027729 [A/G] rs10471103 4 144033656 [T/G] rs11100769 4 144043466 [T/C] rs4690772 4 144051108 [T/C] rs11933189 4 144055140 [T/C] rs7666785 4 144060464 [A/G] rs11100775 4 144073912 [A/G] rs13109025 4 144086419 [T/G] rs11100780 4 144104906 [A/G] NR_136203 LOC105377623 Silent rs13140326 4 144114413 [A/G] NM_001290325,NM_001290326,NM_032557 USP38,USP38,USP38 Silent,Silent,Silent rs10155329 4 144117668 [A/G] NM_001290325,NM_001290326,NM_032557 USP38,USP38,USP38 Silent,Silent,Silent rs10008314 4 144118172 [T/C] NM_001290325,NM_001290326,NM_032557 USP38,USP38,USP38 Silent,Silent,Silent rs7670426 4 144130750 [T/C] NM_001290325,NM_001290326,NM_032557 USP38,USP38,USP38 EXON Synonymous_N479N,Synonymous_N24N,Synonymous_N479N rs4285045 4 144135718 [A/G] NM_001290325,NM_001290326,NM_032557 USP38,USP38,USP38 EXON Synonymous_R863R,Synonymous_R408R,Synonymous_R863R rs10000911 4 144136193 [T/G] NM_001290325,NM_001290326,NM_032557 USP38,USP38,USP38 EXON Silent,Silent,Silent rs11735537 4 144150701 [T/C] rs300942 4 144174773 [A/C] rs10519678 4 144182073 [T/C] rs893929 4 144187380 [A/G] rs763918 4 144193117 [T/G] rs13114280 4 144193695 [A/G] rs300948 4 144198204 [T/C] rs300951 4 144201383 [T/C] rs12643013 4 144206948 [T/C] rs17686361 4 144207686 [A/G] rs17017571 4 144217991 [T/C] rs522027 4 144220578 [T/C] rs6537153 4 144230902 [A/C] rs300905 4 144240473 [A/G] rs6825973 4 144261486 [A/G] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs10012162 4 144265413 [T/C] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs17017629 4 144273358 [T/C] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs300913 4 144276643 [T/C] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs300912 4 144276717 [A/G] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs17738628 4 144282005 [A/G] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs1472873 4 144289305 [T/C] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs3805253 4 144289502 [A/G] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs6537155 4 144293053 [A/G] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs7680959 4 144312520 [T/C] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs11937252 4 144315919 [A/G] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs1397528 4 144319745 [A/G] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs17739332 4 144323529 [A/G] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs11941806 4 144324534 [A/G] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs3792651 4 144329781 [A/G] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs2666350 4 144335735 [A/G] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs1995931 4 144340560 [T/C] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs3805236 4 144357737 [A/G] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs17017788 4 144363964 [T/C] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs3795246 4 144381401 [A/G] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs7696619 4 144388923 [A/G] NM_207123,NM_002039 GAB1,GAB1 Silent,Silent rs28924079 4 144390693 [T/G] NM_207123,NM_002039 GAB1,GAB1 EXON Silent,Silent rs11947756 4 144398793 [T/C] rs11735967 4 144401524 [T/C] rs17017810 4 144406061 [A/G] rs6818844 4 144412846 [T/G] rs11730153 4 144426798 [T/C] rs11944532 4 144451912 [A/G] NM_003601 SMARCA5 Silent rs3924845 4 144458198 [A/G] NM_003601 SMARCA5 Silent rs7692376 4 144466050 [A/G] NM_003601 SMARCA5 Silent rs11732122 4 144477601 [A/G] NM_003601 SMARCA5 EXON Silent rs924232 4 144479917 [T/C] rs17017903 4 144479966 [T/C] rs924233 4 144480013 [A/G] rs17017907 4 144480231 [T/C] rs2323187 4 144493185 [A/C] rs17690723 4 144496477 [A/G] rs10032932 4 144508554 [A/G] NM_001168235 FREM3 Silent rs10519696 4 144522627 [T/C] NM_001168235 FREM3 Silent rs1497614 4 144524582 [A/G] NM_001168235 FREM3 Silent rs13149438 4 144526199 [A/G] NM_001168235 FREM3 Silent rs1018092 4 144539138 [A/C] NM_001168235 FREM3 Silent rs17017968 4 144542213 [A/G] NM_001168235 FREM3 EXON Missense_I1919T rs1391187 4 144543099 [A/G] NM_001168235 FREM3 Silent rs13143261 4 144546275 [A/G] NM_001168235 FREM3 Silent rs1497607 4 144549631 [T/C] NM_001168235 FREM3 Silent rs1497608 4 144550211 [T/C] NM_001168235 FREM3 Silent rs1450237 4 144559530 [A/G] NM_001168235 FREM3 Silent rs1826927 4 144574139 [T/G] NM_001168235 FREM3 Silent rs1349325 4 144575873 [T/G] NM_001168235 FREM3 Silent rs1450242 4 144576742 [A/G] NM_001168235 FREM3 Silent rs1375988 4 144578932 [T/G] NM_001168235 FREM3 Silent rs11100801 4 144586417 [T/C] NM_001168235 FREM3 Silent rs6840604 4 144593162 [A/G] NM_001168235 FREM3 Silent rs7676614 4 144616366 [A/G] NM_001168235 FREM3 Silent rs7654410 4 144617316 [T/C] NM_001168235 FREM3 EXON Missense_E1505K rs1545437 4 144617842 [T/G] NM_001168235 FREM3 EXON Synonymous_I1329I rs2019159 4 144635129 [A/C] rs1599822 4 144641391 [A/C] rs9685306 4 144669996 [A/G] rs35243309 4 144676269 [T/C] rs7687915 4 144680954 [T/G] rs1580002 4 144687660 [A/G] rs13101541 4 144727743 [T/G] rs13105102 4 144740199 [A/G] NR_134680 LOC105377458 EXON Silent rs17018500 4 144746002 [T/C] NR_134680 LOC105377458 Silent rs6844978 4 144754147 [A/C] rs7698581 4 144782841 [T/C] rs1822842 4 144784844 [T/C] rs4240334 4 144792505 [A/G] NM_198682 GYPE EXON Silent rs1808991 4 144792959 [T/G] NM_198682 GYPE EXON Silent rs2875045 4 144805433 [T/C] NM_198682,NM_002102 GYPE,GYPE Silent,Silent rs9997931 4 144825754 [T/C] NM_198682,NM_002102 GYPE,GYPE Silent,Silent rs10857415 4 144829906 [T/C] rs2323413 4 144869008 [T/G] NR_125886 LOC101927636 Silent rs4613514 4 144882744 [A/G] NR_125886 LOC101927636 Silent rs9799404 4 144894260 [T/C] NR_125886 LOC101927636 Silent rs11723869 4 144896250 [A/G] NR_125886 LOC101927636 Silent rs1849114 4 144945108 [T/C] rs34617896 4 144949348 [T/C] rs12499639 4 144950193 [A/G] rs1849130 4 144965891 [A/G] rs4597772 4 145004839 [T/C] rs7657795 4 145009802 [A/C] rs6844670 4 145024799 [A/G] rs4535287 4 145028431 [A/G] rs3936169 4 145029870 [T/G] rs3936168 4 145029887 [A/G] rs11728240 4 145030701 [A/G] NM_001308187,NM_002099,NM_001308190 GYPA,GYPA,GYPA EXON Silent,Silent,Silent rs4425323 4 145033532 [A/G] NM_001308187,NM_002099,NM_001308190 GYPA,GYPA,GYPA Silent,Silent,Silent rs4374581 4 145033810 [A/G] NM_001308187,NM_002099,NM_001308190 GYPA,GYPA,GYPA Silent,Silent,Silent rs6857303 4 145035788 [A/G] NM_001308187,NM_002099,NM_001308190 GYPA,GYPA,GYPA Silent,Silent,Silent rs13103731 4 145056487 [T/C] NM_001308187,NM_002099,NM_001308190 GYPA,GYPA,GYPA Silent,Silent,Silent rs7688971 4 145076356 [A/G] rs4402988 4 145088692 [A/G] rs4539990 4 145092857 [T/C] rs9999314 4 145094407 [A/G] rs10857420 4 145099290 [A/C] rs6812128 4 145102264 [T/G] rs3923603 4 145111329 [T/C] rs4599356 4 145123453 [A/G] rs4303930 4 145135525 [A/C] rs4423828 4 145141405 [T/C] rs4425324 4 145142144 [A/C] rs4513513 4 145142571 [A/G] rs4392468 4 145148701 [T/G] rs7658605 4 145151018 [A/G] rs11100843 4 145177682 [T/C] rs7689179 4 145195649 [A/G] rs7681569 4 145203640 [A/G] rs13146588 4 145210834 [A/G] rs12711416 4 145213954 [T/C] rs7674504 4 145214922 [T/C] rs6821055 4 145225998 [A/G] rs11935505 4 145226422 [A/G] rs13118083 4 145227600 [A/G] rs4256191 4 145240011 [A/C] rs6842885 4 145250180 [A/C] rs7377575 4 145254685 [T/C] rs10030023 4 145258807 [A/C] rs6852276 4 145261999 [A/G] rs2719341 4 145263286 [T/G] rs6840871 4 145264014 [T/C] rs6849200 4 145273780 [A/C] rs6537279 4 145275039 [A/G] rs17766287 4 145278837 [T/C] rs2657799 4 145282779 [T/C] rs6840917 4 145286433 [A/G] rs970022 4 145293039 [T/C] rs1394998 4 145302155 [T/C] rs17019341 4 145334169 [T/C] rs12512146 4 145347980 [T/G] rs7695767 4 145353554 [T/C] rs1602238 4 145363247 [T/C] rs11940095 4 145378417 [T/C] rs7684769 4 145419510 [T/C] rs12641251 4 145424843 [A/G] rs11935246 4 145429056 [T/C] rs6827794 4 145430297 [T/C] rs1512282 4 145431497 [A/G] rs1032296 4 145434688 [T/C] rs1032297 4 145434744 [A/G] rs7677035 4 145437319 [A/G] rs6854832 4 145441759 [T/C] rs6845536 4 145452783 [T/C] rs6824927 4 145471137 [A/C] rs1980057 4 145485738 [T/C] rs7655625 4 145485915 [T/C] rs6828255 4 145489265 [A/C] rs17019499 4 145499204 [A/C] rs13136959 4 145500596 [T/C] rs6852830 4 145506558 [A/C] rs7670758 4 145511875 [A/G] rs7677662 4 145513053 [A/G] rs4835180 4 145520608 [A/G] rs17776795 4 145544836 [A/G] rs2575574 4 145544935 [A/G] rs2639582 4 145546540 [A/G] rs2575570 4 145548933 [T/G] rs2575572 4 145552729 [T/C] rs1398244 4 145562457 [T/C] rs6845999 4 145565826 [T/C] NR_037595 HHIP-AS1 Silent rs7689420 4 145568352 [T/C] NM_022475 HHIP Silent rs2306924 4 145582536 [A/G] NM_022475 HHIP Silent rs982902 4 145586900 [A/G] NM_022475 HHIP Silent rs6819412 4 145605033 [T/C] NM_022475 HHIP Silent rs6537309 4 145605075 [T/C] NM_022475 HHIP Silent rs1492819 4 145619413 [T/C] NM_022475 HHIP Silent rs6838704 4 145623107 [A/G] NM_022475 HHIP Silent rs7654947 4 145625730 [T/C] NM_022475 HHIP Silent rs7696711 4 145627583 [T/C] NM_022475 HHIP Silent rs11100863 4 145633530 [A/G] NM_022475 HHIP Silent rs6854783 4 145643079 [A/G] NM_022475 HHIP Silent rs1492818 4 145646554 [A/G] NM_022475 HHIP Silent rs1492820 4 145650021 [A/G] NM_022475 HHIP Silent rs1472174 4 145655532 [T/G] NM_022475 HHIP Silent rs11727676 4 145659064 [T/C] NM_022475 HHIP EXON Synonymous_I686I rs2639577 4 145661910 [A/G] rs11944404 4 145670871 [T/C] rs2353934 4 145697040 [T/C] rs7442087 4 145707662 [A/C] rs10857421 4 145739142 [T/C] rs6537319 4 145761160 [T/C] rs12651029 4 145770167 [A/G] rs13102609 4 145771221 [T/G] rs4555661 4 145782963 [T/C] rs11100870 4 145822014 [T/G] rs813139 4 145858473 [A/G] rs789344 4 145889835 [A/G] rs813138 4 145914748 [A/G] rs17019822 4 145916510 [T/C] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NM_001318367,NR_046345,NM_001256711,NM_001256712 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1086103 4 145920099 [A/C] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NM_001318367,NR_046345,NM_001256711,NM_001256712 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs224005 4 145960134 [T/C] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NM_001318367,NR_046345,NM_001256711,NM_001256712 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2162090 4 145960467 [T/C] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NM_001318367,NR_046345,NM_001256711,NM_001256712 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2007345 4 145961040 [T/C] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NM_001318367,NR_046345,NM_001256711,NM_001256712 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11734845 4 145974688 [A/G] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NM_001318367,NR_046345,NM_001256711,NM_001256712 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10032067 4 145978910 [T/G] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NM_001318367,NR_046345,NM_001256711,NM_001256712 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17781702 4 145984839 [A/C] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NM_001318367,NR_046345,NM_001256711,NM_001256712 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12331496 4 145989190 [A/G] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NM_001318367,NR_046345,NM_001256711,NM_001256712 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13115967 4 145996754 [T/C] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NM_001318367,NR_046345,NM_001256711,NM_001256712 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13136718 4 146013265 [A/G] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NM_001318367,NR_046345,NM_001256711,NM_001256712 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13120407 4 146017618 [T/C] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NM_001318367,NR_046345,NM_001256711,NM_001256712 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2124206 4 146018758 [T/C] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NR_046345,NM_001256711,NM_001256712 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs34683609 4 146019197 [T/C] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NR_046345,NM_001256711,NM_001256712,NM_002940,NM_001040876 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ABCE1,ABCE1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs33981816 4 146019280 [A/G] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NR_046345,NM_001256711,NM_001256712,NM_002940,NM_001040876 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ABCE1,ABCE1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs35596291 4 146019340 [G/C] NM_001256706,NM_001256707,NM_001256708,NM_001256709,NM_001256710,NM_014885,NR_046345,NM_001256711,NM_001256712,NM_002940,NM_001040876 ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ANAPC10,ABCE1,ABCE1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs34766684 4 146023924 [T/C] NM_002940,NM_001040876 ABCE1,ABCE1 Silent,Silent rs34265438 4 146025645 [A/G] NM_002940,NM_001040876 ABCE1,ABCE1 EXON Synonymous_K27K,Synonymous_K27K rs35207405 4 146031396 [A/G] NM_002940,NM_001040876 ABCE1,ABCE1 Silent,Silent rs35152106 4 146031427 [A/G] NM_002940,NM_001040876 ABCE1,ABCE1 Silent,Silent rs34149094 4 146036388 [A/G] NM_002940,NM_001040876 ABCE1,ABCE1 Silent,Silent rs34330278 4 146037320 [A/G] NM_002940,NM_001040876 ABCE1,ABCE1 Silent,Silent rs34394048 4 146041711 [A/G] NM_002940,NM_001040876 ABCE1,ABCE1 Silent,Silent rs35729907 4 146044393 [A/G] NM_002940,NM_001040876 ABCE1,ABCE1 EXON Synonymous_L467L,Synonymous_L467L rs34516722 4 146050502 [T/C] NM_002940,NM_001040876 ABCE1,ABCE1 EXON Silent,Silent rs7661953 4 146053559 [T/C] rs11545157 4 146055117 [T/C] NM_001102653 OTUD4 EXON Silent rs11731583 4 146061560 [A/G] NM_001102653 OTUD4 Silent rs12502109 4 146068652 [T/C] NM_001102653 OTUD4 Silent rs11942615 4 146073143 [A/G] NM_001102653 OTUD4 Silent rs11734405 4 146081096 [T/C] NM_001102653,NM_017493 OTUD4,OTUD4 Silent,Silent rs6845553 4 146082942 [T/C] NM_001102653,NM_017493 OTUD4,OTUD4 Silent,Silent rs6816812 4 146123564 [T/C] rs2355233 4 146125343 [A/G] rs11736535 4 146139896 [A/G] rs6844904 4 146167657 [A/G] rs10013728 4 146173197 [T/C] rs11100872 4 146184565 [A/G] rs4835001 4 146188270 [T/C] rs13141761 4 146188881 [A/G] rs6833910 4 146193967 [T/C] rs6822403 4 146194938 [T/C] rs17019992 4 146197201 [A/G] rs2355620 4 146201203 [A/G] rs10006257 4 146205494 [T/C] rs2355617 4 146210435 [T/C] rs13109698 4 146211177 [T/C] rs6825120 4 146213427 [A/C] rs4373182 4 146220802 [T/G] rs11930564 4 146220888 [T/C] rs2705575 4 146226787 [A/G] rs11728665 4 146232373 [T/C] rs28606996 4 146243587 [A/C] rs6537340 4 146249655 [A/G] rs11931253 4 146254791 [T/G] rs1489152 4 146256922 [T/C] NR_147156 LINC02266 EXON Silent rs4240328 4 146257067 [T/G] NR_147156 LINC02266 EXON Silent rs1596480 4 146258152 [A/G] NR_147156 LINC02266 Silent rs7668650 4 146260382 [T/C] NR_147156 LINC02266 Silent rs568752 4 146262747 [T/C] rs11731479 4 146270748 [A/G] rs514422 4 146270827 [A/G] rs920840 4 146276195 [T/C] rs3849041 4 146281857 [T/C] rs12513059 4 146285738 [T/G] rs2044276 4 146297328 [A/G] rs10011126 4 146298227 [A/G] rs479884 4 146306977 [A/G] rs6842280 4 146307650 [T/C] rs17728991 4 146309232 [T/C] rs10016954 4 146314357 [T/C] rs1444086 4 146314863 [T/G] rs7674130 4 146315063 [A/G] rs1992598 4 146334754 [T/C] rs13113847 4 146347867 [T/C] rs9684285 4 146350184 [T/C] rs499629 4 146358876 [A/G] rs13109195 4 146369756 [T/C] rs6537355 4 146402592 [A/G] NM_001354812 SMAD1 Silent rs17020200 4 146404652 [A/G] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6816306 4 146407524 [A/G] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6823513 4 146411000 [A/G] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11944685 4 146414267 [A/G] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7694604 4 146430293 [T/G] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11938489 4 146433817 [T/G] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17020269 4 146434229 [T/C] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11100883 4 146450970 [A/G] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6852200 4 146452773 [T/C] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7670486 4 146453921 [A/G] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11937875 4 146460053 [T/C] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3756021 4 146461534 [T/C] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7662543 4 146464773 [T/C] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6829932 4 146478467 [T/C] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1016792 4 146478779 [T/C] NM_001354812,NM_001354814,NM_001354813,NM_005900,NM_001354816,NM_001354811,NM_001354817,NM_001003688 SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1,SMAD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13120931 4 146482020 [T/G] rs6848760 4 146484997 [A/C] rs11944100 4 146488217 [A/G] rs11939979 4 146488327 [A/C] rs7662930 4 146495355 [T/C] rs6842568 4 146501892 [A/G] rs17020372 4 146503099 [A/G] rs1874572 4 146509970 [T/G] rs2132781 4 146511615 [T/G] rs1497125 4 146539630 [T/C] rs17020432 4 146543677 [A/C] NM_172250 MMAA Silent rs17008702 4 146545470 [T/C] NM_172250 MMAA Silent rs1390981 4 146546701 [A/G] NM_172250 MMAA Silent rs17020454 4 146548279 [T/C] NM_172250 MMAA Silent rs13130076 4 146551432 [A/G] NM_172250 MMAA Silent rs17743530 4 146557594 [T/G] NM_172250 MMAA Silent rs17020467 4 146559160 [A/G] NM_172250 MMAA Silent rs4835011 4 146560236 [A/G] NM_172250 MMAA EXON Silent rs4835014 4 146566650 [T/G] NM_172250 MMAA Silent rs17014946 4 146567584 [T/G] NM_172250 MMAA Silent rs17020500 4 146579452 [A/G] NM_172250 MMAA EXON Silent rs9308191 4 146586214 [A/G] rs6831899 4 146589780 [T/C] rs7688920 4 146592982 [T/G] rs17744367 4 146595347 [A/C] rs17020528 4 146601349 [T/C] rs7682360 4 146601701 [A/G] NM_001080531 C4orf51 Silent rs17020536 4 146602241 [A/C] NM_001080531 C4orf51 Silent rs7678910 4 146603460 [T/C] NM_001080531 C4orf51 Silent rs2132778 4 146614073 [T/C] NM_001080531 C4orf51 Silent rs10084798 4 146628662 [T/G] NM_001080531 C4orf51 Silent rs2036136 4 146631230 [T/C] NM_001080531 C4orf51 Silent rs6537368 4 146635806 [T/C] NM_001080531 C4orf51 Silent rs4487368 4 146636404 [T/C] NM_001080531 C4orf51 Silent rs9999510 4 146638036 [A/G] NM_001080531 C4orf51 Silent rs6818284 4 146639208 [A/G] NM_001080531 C4orf51 Silent rs10003327 4 146639774 [A/C] NM_001080531 C4orf51 Silent rs9997749 4 146642017 [T/C] NM_001080531 C4orf51 Silent rs3935131 4 146651446 [T/G] NM_001080531 C4orf51 Silent rs6841736 4 146656795 [A/G] rs7690184 4 146662794 [A/C] rs11934305 4 146663390 [T/C] rs4591626 4 146669242 [T/C] rs12500371 4 146681477 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 EXON Silent,Silent rs11939704 4 146685889 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs4835257 4 146697205 [A/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs7677608 4 146703852 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs4521364 4 146709412 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs6836085 4 146713382 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs10010535 4 146717169 [A/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs6854834 4 146722152 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs1567220 4 146725972 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs1396055 4 146730687 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs17806780 4 146732654 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs7656212 4 146737421 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs9790518 4 146745835 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs17020623 4 146746625 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs6855560 4 146746651 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs11100901 4 146746960 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs10011020 4 146747838 [A/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs17020641 4 146748659 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs17745264 4 146748876 [T/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs13149290 4 146750966 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs17020662 4 146751207 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs17020677 4 146752366 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs17020691 4 146764719 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs988163 4 146764883 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs4544728 4 146768394 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs17303543 4 146775428 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs13128681 4 146776836 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs6814298 4 146780732 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs6821030 4 146781717 [A/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs4835261 4 146781747 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs925136 4 146788825 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs4547811 4 146794621 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs11100902 4 146795226 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs17020769 4 146800922 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs10003934 4 146809898 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs13119482 4 146817630 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs9790707 4 146818215 [T/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs4835267 4 146824778 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs2135961 4 146825650 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs4835268 4 146826299 [T/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs4835024 4 146826444 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs12332040 4 146829530 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs1567224 4 146840077 [T/C] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs12641158 4 146842502 [T/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs12331851 4 146849295 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs1472866 4 146849715 [A/G] NM_178835,NM_001306215 ZNF827,ZNF827 Silent,Silent rs7679276 4 146860186 [A/G] rs9996164 4 146862215 [T/C] rs7659884 4 146866150 [A/C] rs6537382 4 146867376 [A/C] rs6537383 4 146870683 [A/G] rs723794 4 146875551 [T/G] rs7698461 4 146883385 [A/G] rs10025229 4 146889338 [T/G] rs9968429 4 146890261 [A/G] rs7657882 4 146893493 [A/G] rs4543136 4 146893952 [A/C] rs1579388 4 146894530 [T/C] rs6820440 4 146897773 [A/G] rs7660035 4 146901801 [T/C] rs11100904 4 146904304 [T/C] rs17020816 4 146931256 [A/G] rs10434119 4 146932089 [T/C] rs6537391 4 146933473 [A/C] rs4835275 4 146945603 [T/C] rs17809246 4 146946713 [T/C] rs17020895 4 146948669 [A/C] rs17020919 4 146958602 [T/C] rs13125215 4 146961679 [T/C] rs9991712 4 146968904 [A/G] rs13142208 4 146974543 [T/C] rs1426888 4 146983240 [A/G] rs12642634 4 146985627 [A/G] rs10007440 4 146987110 [A/C] rs11932033 4 146987500 [T/C] rs6845844 4 146994618 [A/G] rs6842373 4 146998070 [T/C] rs2241521 4 146999111 [A/C] rs6821225 4 147002718 [T/C] rs11100914 4 147012038 [T/C] rs7666409 4 147012650 [T/C] rs10012073 4 147015936 [A/G] rs10857425 4 147019583 [A/G] rs4835030 4 147028405 [A/G] rs10017509 4 147029511 [T/C] rs11734320 4 147037222 [T/C] NR_038331 LINC01095 Silent rs11722991 4 147037235 [T/C] NR_038331 LINC01095 Silent rs11721815 4 147042373 [A/G] NR_038331 LINC01095 Silent rs13141665 4 147051347 [A/G] rs2007366 4 147054644 [T/G] rs17021097 4 147055240 [A/G] rs13101861 4 147059435 [A/G] rs17021126 4 147065202 [A/G] rs6841228 4 147071801 [A/C] rs17021150 4 147081338 [A/G] rs7356451 4 147090211 [A/G] rs6815527 4 147097293 [T/C] NM_007080 LSM6 Silent rs919483 4 147104263 [A/G] NM_007080 LSM6 Silent rs11100918 4 147112495 [A/G] rs6844381 4 147118845 [T/C] rs1865532 4 147120075 [T/C] rs6821444 4 147127987 [T/C] rs12374409 4 147135668 [T/C] rs16998675 4 147138193 [T/C] NM_001354631 REELD1 EXON Missense_T30M rs1864372 4 147143572 [A/G] NM_001354631 REELD1 EXON Missense_H91R rs2278471 4 147151858 [A/G] NM_001354631 REELD1 EXON Silent rs7676643 4 147159504 [T/C] rs874851 4 147163132 [A/G] rs6857756 4 147165756 [T/C] rs11729554 4 147168885 [T/C] rs7656598 4 147169761 [A/C] rs10032233 4 147170097 [T/C] rs13122077 4 147171388 [A/C] rs7676356 4 147174997 [A/G] rs1036016 4 147176603 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 EXON Silent,Silent,Silent,Silent rs1057560 4 147177341 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 EXON Silent,Silent,Silent,Silent rs11930848 4 147177468 [T/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 EXON Silent,Silent,Silent,Silent rs17021302 4 147177773 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs28406249 4 147177822 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs2356940 4 147180527 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs17021329 4 147189101 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs1960018 4 147198667 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs10032088 4 147215026 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs9784437 4 147216089 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs9784489 4 147216213 [T/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs17021355 4 147217867 [T/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs17021362 4 147220412 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs2101345 4 147221103 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs10212747 4 147230765 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs6844812 4 147246721 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs4835294 4 147247694 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs9991483 4 147252599 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs4835297 4 147260476 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs6828612 4 147269334 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs10009867 4 147280685 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs2679144 4 147295128 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs3849034 4 147314034 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs2356820 4 147320219 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs6826676 4 147323331 [A/C] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs2679141 4 147325925 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs6858794 4 147326974 [T/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs2679157 4 147336656 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs7699206 4 147339907 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs10017463 4 147351628 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842 SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent rs13105153 4 147365170 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842,NM_001317817,NM_032128 SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent,Silent,Silent rs6537420 4 147370156 [T/G] NR_133924,NM_001317816,NM_001029998,NM_001300842,NM_001317817,NM_032128 SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent,Silent,Silent rs11944523 4 147374979 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842,NM_001317817,NM_032128 SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent,Silent,Silent rs7663212 4 147376576 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842,NM_001317817,NM_032128 SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent,Silent,Silent rs11734649 4 147391468 [T/G] NR_133924,NM_001317816,NM_001029998,NM_001300842,NM_001317817,NM_032128 SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent,Silent,Silent rs12711436 4 147412986 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842,NM_001317817,NM_032128 SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent,Silent,Silent rs7665599 4 147414147 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842,NM_001317817,NM_032128 SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent,Silent,Silent rs13149914 4 147416669 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842,NM_001317817,NM_032128 SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent,Silent,Silent rs4835040 4 147424678 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842,NM_001317817,NM_032128 SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent,Silent,Silent rs6849958 4 147426105 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842,NM_001317817,NM_032128 SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent,Silent,Silent rs13152024 4 147429316 [A/G] NR_133924,NM_001317816,NM_001029998,NM_001300842,NM_001317817,NM_032128 SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent,Silent,Silent rs3914628 4 147438019 [T/C] NR_133924,NM_001317816,NM_001029998,NM_001300842,NM_001317817,NM_032128,NM_001317818 SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4550954 4 147439250 [T/G] NR_133924,NM_001317816,NM_001029998,NM_001300842,NM_001317817,NM_032128,NM_001317818 SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7,SLC10A7 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2884092 4 147447028 [T/C] rs7679939 4 147454992 [A/G] rs4835042 4 147464245 [A/C] rs1504355 4 147469133 [T/G] rs9996620 4 147473314 [A/G] rs17770092 4 147481601 [T/C] rs1504359 4 147495449 [T/C] rs17832354 4 147499642 [A/G] rs10005397 4 147505431 [T/C] rs7680105 4 147507651 [A/G] rs10014502 4 147514051 [A/G] rs17021624 4 147522465 [A/G] rs6835151 4 147529209 [A/G] rs2134852 4 147535168 [A/G] rs1875844 4 147538064 [A/G] rs13138020 4 147545471 [T/C] rs970674 4 147551074 [A/G] rs9994157 4 147551241 [T/C] rs17021710 4 147552027 [T/C] rs13152799 4 147560411 [T/C] NM_004575 POU4F2 EXON Missense_I40T rs6537429 4 147566988 [A/G] rs7689436 4 147573688 [T/C] rs17021755 4 147580638 [A/G] rs6839406 4 147582941 [T/C] rs1857721 4 147591367 [T/C] rs1504353 4 147610480 [A/G] rs17772451 4 147619089 [A/G] rs7673381 4 147624277 [T/C] rs1394272 4 147633134 [A/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs1504354 4 147636699 [A/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs2713878 4 147641087 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs4835336 4 147642738 [A/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs4476620 4 147648358 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs4484319 4 147651538 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs10027612 4 147658082 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs1509332 4 147664762 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs1509331 4 147665728 [A/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs7671336 4 147666797 [A/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs10519819 4 147688226 [A/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs952639 4 147701619 [A/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs10446756 4 147717009 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs7674628 4 147720217 [A/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs12504096 4 147734508 [A/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs6857108 4 147751943 [A/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs17021996 4 147754819 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs2036728 4 147755975 [T/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs1509339 4 147757175 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs17022009 4 147761369 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs17022031 4 147768045 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs6855967 4 147768206 [A/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs17610019 4 147783128 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs10018635 4 147783160 [A/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs12507364 4 147785578 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs1396716 4 147787745 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs10013280 4 147788709 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 EXON Missense_A302T,Missense_A276T,Silent,Missense_A276T rs10001365 4 147797214 [A/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs7656258 4 147809311 [A/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs984696 4 147820477 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs10033420 4 147823399 [A/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs17610219 4 147824864 [A/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 EXON Missense_H166Y,Missense_H140Y,Silent,Missense_H140Y rs13122121 4 147834758 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs17022118 4 147839631 [A/G] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs1509333 4 147850007 [T/C] NM_001300761,NM_031956,NR_133922,NM_001317806 TTC29,TTC29,TTC29,TTC29 Silent,Silent,Silent,Silent rs3827595 4 147867307 [T/C] rs17022172 4 147886887 [A/G] rs7663340 4 147897673 [T/C] rs1347655 4 147905897 [T/C] rs9918010 4 147908124 [A/G] rs1595309 4 147909409 [T/C] rs4467588 4 147917821 [A/G] rs17022256 4 147919958 [T/C] rs10011414 4 147923940 [T/C] rs974278 4 147925900 [T/C] rs12498817 4 147927227 [T/C] rs1370299 4 147935557 [T/C] rs6537444 4 147940034 [T/C] rs6813768 4 147941013 [A/G] rs6537445 4 147941253 [T/C] rs1370300 4 147941480 [A/G] rs7665036 4 147945451 [T/C] rs10019569 4 147946604 [T/C] rs1370301 4 147947622 [T/G] rs1561223 4 147964863 [A/G] rs11734148 4 147964933 [A/G] rs10008795 4 147970022 [A/G] rs4835363 4 147970692 [A/C] rs10446782 4 147972073 [T/C] rs7674049 4 147979721 [T/C] rs4835063 4 147980595 [T/C] rs4835367 4 147983095 [A/G] rs6855501 4 147991697 [T/C] rs1507499 4 147993672 [A/G] rs1507500 4 147993702 [A/G] rs10034640 4 147994381 [A/G] rs7667695 4 147998571 [T/C] rs4571308 4 147998958 [A/G] rs17022539 4 148001517 [A/G] rs10212894 4 148001572 [A/G] rs4383597 4 148005660 [A/G] rs4379045 4 148006860 [A/G] rs4414935 4 148011063 [T/C] rs1979956 4 148012476 [A/G] rs11942353 4 148017587 [T/G] rs17022582 4 148017820 [A/G] rs1911588 4 148021144 [T/C] rs4543091 4 148025559 [T/C] rs10034616 4 148031028 [A/C] rs7677110 4 148039230 [A/G] rs4835378 4 148040980 [T/G] rs11947386 4 148051109 [T/G] rs4485803 4 148051452 [A/G] rs17022703 4 148060315 [A/C] rs12499925 4 148066627 [T/G] rs2174801 4 148069540 [T/C] rs1354884 4 148075340 [A/G] rs2357604 4 148077418 [T/C] rs952688 4 148081634 [T/C] rs4399964 4 148084305 [A/G] rs17022766 4 148093804 [T/C] rs17022775 4 148099831 [A/G] rs10519879 4 148126895 [T/C] rs4835382 4 148131784 [T/C] rs7656015 4 148162962 [A/G] rs7658280 4 148171265 [T/G] rs4835074 4 148174084 [T/G] rs12644017 4 148200205 [A/G] rs6841482 4 148209824 [T/G] rs2714886 4 148229316 [A/G] rs2163012 4 148268027 [A/G] rs4835078 4 148277011 [A/G] rs17023122 4 148280874 [T/G] rs1429142 4 148289389 [T/C] rs1560228 4 148291697 [A/G] rs1429102 4 148301706 [T/C] rs11936867 4 148306058 [A/G] rs11939391 4 148308111 [A/G] rs7669258 4 148308126 [T/C] rs13140736 4 148309369 [A/C] rs17674732 4 148311822 [A/G] rs7671190 4 148318048 [A/C] rs1429107 4 148322387 [A/G] rs2195469 4 148328556 [T/C] rs17023204 4 148329646 [T/C] rs1429115 4 148337747 [A/G] rs1594085 4 148349756 [A/G] rs4835398 4 148353423 [T/G] rs1429123 4 148353940 [T/C] rs17023262 4 148362457 [A/G] rs1560231 4 148362953 [A/G] rs2063936 4 148370419 [T/C] rs10001478 4 148374931 [A/G] rs10026914 4 148375008 [A/C] rs9999944 4 148376995 [A/C] rs1400558 4 148380805 [T/C] rs6537478 4 148385094 [T/C] rs4333164 4 148396927 [T/C] rs6842241 4 148400819 [A/C] rs1801708 4 148402369 [A/G] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA EXON Silent,Silent,Silent,Silent,Silent,Silent rs6855875 4 148402737 [T/C] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent,Silent rs1996374 4 148413483 [A/G] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent,Silent rs17612742 4 148414651 [T/C] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent,Silent rs10305875 4 148416889 [A/G] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent,Silent rs6848108 4 148422625 [A/G] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent,Silent rs4591581 4 148429102 [A/G] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent,Silent rs10305889 4 148434128 [T/C] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent,Silent rs10305895 4 148434688 [A/G] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent,Silent rs6827096 4 148435446 [T/C] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent,Silent rs9999853 4 148436871 [T/C] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent,Silent rs11939191 4 148438715 [A/G] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent,Silent rs1878404 4 148440625 [A/G] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent,Silent rs4835412 4 148441139 [A/G] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent,Silent rs10008744 4 148445429 [A/C] NM_001354797,NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent,Silent rs4639051 4 148448870 [A/G] NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA Silent,Silent,Silent,Silent,Silent rs5334 4 148461073 [A/G] NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA EXON Silent,Silent,Silent,Synonymous_E335E,Synonymous_E226E rs5338 4 148464269 [A/G] NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA EXON Silent,Silent,Silent,Silent,Silent rs10305935 4 148464816 [A/C] NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA EXON Silent,Silent,Silent,Silent,Silent rs5343 4 148464992 [T/C] NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA EXON Silent,Silent,Silent,Silent,Silent rs5344 4 148465299 [A/G] NR_045958,NR_148964,NR_148963,NM_001957,NM_001166055 EDNRA,EDNRA,EDNRA,EDNRA,EDNRA EXON Silent,Silent,Silent,Silent,Silent rs17613180 4 148486299 [A/G] rs2090422 4 148488545 [T/C] rs4110 4 148499607 [T/C] rs7675774 4 148503298 [A/G] rs4835088 4 148509519 [A/G] rs10028794 4 148510474 [T/C] rs10519904 4 148510725 [T/C] rs4835438 4 148522294 [A/G] rs11932883 4 148525677 [T/C] rs10010511 4 148529193 [T/C] rs6848237 4 148529844 [A/G] rs10519911 4 148550590 [T/C] NM_018241 TMEM184C Silent rs13119467 4 148553461 [A/G] NM_018241 TMEM184C Silent rs2654937 4 148554421 [T/C] NM_018241 TMEM184C Silent rs2654936 4 148559136 [T/G] NM_001304458,NM_001350144,NM_001350141,NM_001350142,NM_001350143,NM_138364 PRMT9,PRMT9,PRMT9,PRMT9,PRMT9,PRMT9 EXON Silent,Silent,Silent,Silent,Silent,Silent rs17675537 4 148559848 [A/G] NM_001304458,NM_001350144,NM_001350141,NM_001350142,NM_001350143,NM_138364 PRMT9,PRMT9,PRMT9,PRMT9,PRMT9,PRMT9 EXON Synonymous_H678H,Synonymous_H383H,Synonymous_H435H,Synonymous_H678H,Synonymous_H486H,Synonymous_H791H rs11557361 4 148560193 [T/C] NM_001304458,NM_001350144,NM_001350141,NM_001350142,NM_001350143,NM_138364 PRMT9,PRMT9,PRMT9,PRMT9,PRMT9,PRMT9 EXON Missense_C634Y,Missense_C339Y,Missense_C391Y,Missense_C634Y,Missense_C442Y,Missense_C747Y rs17475359 4 148566463 [T/C] NM_001304458,NM_001350144,NM_001350141,NM_001350142,NM_001350143,NM_138364 PRMT9,PRMT9,PRMT9,PRMT9,PRMT9,PRMT9 Silent,Silent,Silent,Silent,Silent,Silent rs13152706 4 148570053 [A/G] NM_001304458,NM_001350144,NM_001350141,NM_001350142,NM_001350143,NM_138364 PRMT9,PRMT9,PRMT9,PRMT9,PRMT9,PRMT9 Silent,Silent,Silent,Silent,Silent,Silent rs12508763 4 148578202 [A/G] NM_001304458,NM_001350144,NM_001350141,NM_001350142,NM_001350143,NM_138364 PRMT9,PRMT9,PRMT9,PRMT9,PRMT9,PRMT9 Silent,Silent,Silent,Silent,Silent,Silent rs11731298 4 148612488 [T/C] rs4835446 4 148631527 [A/G] rs12502667 4 148648861 [T/C] rs6836509 4 148654651 [T/C] NM_024605 ARHGAP10 Silent rs7675343 4 148658108 [A/G] NM_024605 ARHGAP10 Silent rs17023732 4 148659137 [T/C] NM_024605 ARHGAP10 Silent rs17023763 4 148680186 [A/G] NM_024605 ARHGAP10 Silent rs6845560 4 148687610 [A/G] NM_024605 ARHGAP10 Silent rs6535561 4 148694658 [T/C] NM_024605 ARHGAP10 Silent rs964170 4 148695956 [T/G] NM_024605 ARHGAP10 Silent rs13136202 4 148698365 [T/C] NM_024605 ARHGAP10 Silent rs6837391 4 148722083 [A/G] NM_024605 ARHGAP10 Silent rs10012122 4 148723475 [A/G] NM_024605 ARHGAP10 Silent rs17023845 4 148727355 [T/G] NM_024605 ARHGAP10 Silent rs747097 4 148730825 [T/C] NM_024605 ARHGAP10 Silent rs4835457 4 148733764 [T/G] NM_024605 ARHGAP10 Silent rs7683103 4 148734627 [A/G] NM_024605 ARHGAP10 Silent rs10519917 4 148735644 [T/C] NM_024605 ARHGAP10 Silent rs2043644 4 148740219 [A/G] NM_024605 ARHGAP10 Silent rs893023 4 148752359 [A/G] NM_024605 ARHGAP10 Silent rs9996108 4 148753310 [A/G] NM_024605 ARHGAP10 Silent rs10461235 4 148760097 [A/G] NM_024605 ARHGAP10 Silent rs6846899 4 148762097 [T/C] NM_024605 ARHGAP10 Silent rs11737346 4 148763687 [T/C] NM_024605 ARHGAP10 Silent rs1013842 4 148783402 [A/G] NM_024605 ARHGAP10 Silent rs4240341 4 148787669 [A/G] NM_024605 ARHGAP10 Silent rs12331562 4 148789141 [A/G] NM_024605 ARHGAP10 Silent rs2118034 4 148790648 [A/G] NM_024605 ARHGAP10 Silent rs11734619 4 148798090 [A/G] NM_024605 ARHGAP10 Silent rs10026985 4 148798473 [A/G] NM_024605 ARHGAP10 Silent rs6840771 4 148799613 [A/G] NM_024605 ARHGAP10 Silent rs17676080 4 148815028 [T/C] NM_024605 ARHGAP10 Silent rs893033 4 148820632 [A/G] NM_024605 ARHGAP10 Silent rs17024101 4 148822403 [A/G] NM_024605 ARHGAP10 Silent rs3857095 4 148822783 [A/C] NM_024605 ARHGAP10 Silent rs12509618 4 148827747 [A/C] NM_024605 ARHGAP10 Silent rs12643550 4 148828922 [A/C] NM_024605 ARHGAP10 Silent rs1529935 4 148830472 [T/C] NM_024605 ARHGAP10 Silent rs7655265 4 148838054 [A/C] NM_024605 ARHGAP10 Silent rs4027115 4 148839717 [A/G] NM_024605 ARHGAP10 Silent rs4835111 4 148848283 [T/G] NM_024605 ARHGAP10 Silent rs187005 4 148856057 [A/G] NM_024605 ARHGAP10 Silent rs2635266 4 148866526 [A/G] NM_024605 ARHGAP10 Silent rs17024182 4 148872492 [A/C] NM_024605 ARHGAP10 Silent rs2262881 4 148873538 [A/G] NM_024605 ARHGAP10 Silent rs2635259 4 148874351 [A/G] NM_024605 ARHGAP10 Silent rs2575581 4 148878191 [A/G] NM_024605 ARHGAP10 Silent rs17024201 4 148879583 [T/C] NM_024605 ARHGAP10 Silent rs17024235 4 148891027 [T/C] NM_024605 ARHGAP10 Silent rs9684012 4 148897030 [T/C] NM_024605 ARHGAP10 Silent rs11099673 4 148899082 [A/G] NM_024605 ARHGAP10 Silent rs13129809 4 148903388 [T/G] NM_024605 ARHGAP10 Silent rs10519933 4 148916437 [A/G] NM_024605 ARHGAP10 Silent rs10025443 4 148928002 [A/G] NM_024605 ARHGAP10 Silent rs10003349 4 148928213 [A/G] NM_024605 ARHGAP10 Silent rs12643170 4 148928372 [A/G] NM_024605 ARHGAP10 Silent rs10213376 4 148936414 [T/G] NM_024605 ARHGAP10 Silent rs6815554 4 148938598 [A/C] NM_024605 ARHGAP10 Silent rs9991394 4 148940093 [T/C] NM_024605 ARHGAP10 Silent rs13111299 4 148950412 [T/C] NM_024605 ARHGAP10 Silent rs7668569 4 148950873 [A/G] NM_024605 ARHGAP10 Silent rs6839459 4 148952982 [A/G] NM_024605 ARHGAP10 Silent rs6845865 4 148974602 [T/C] NM_024605 ARHGAP10 Silent rs1021956 4 148979174 [T/G] NM_024605 ARHGAP10 Silent rs10857228 4 148979700 [T/C] NM_024605 ARHGAP10 Silent rs13109093 4 148983139 [A/C] NM_024605 ARHGAP10 Silent rs10519931 4 148983376 [A/G] NM_024605 ARHGAP10 Silent rs2276932 4 148984321 [A/G] NM_024605 ARHGAP10 EXON Missense_M684V rs12650033 4 148987187 [A/G] NM_024605 ARHGAP10 Silent rs7660368 4 148987972 [T/C] NM_024605 ARHGAP10 Silent rs6824449 4 148990995 [A/G] NM_024605 ARHGAP10 Silent rs11933380 4 148997402 [T/C] rs7696997 4 148998566 [T/C] rs2871 4 149000024 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 EXON Silent,Silent,Silent,Silent rs5536 4 149000693 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 EXON Silent,Silent,Silent,Silent rs5534 4 149001085 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 EXON Silent,Silent,Silent,Silent rs9993133 4 149016541 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6840127 4 149018311 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs13137823 4 149022906 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs17024387 4 149024260 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs11737660 4 149024413 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs1879827 4 149025406 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs13142954 4 149030027 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs1879829 4 149035449 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs17483391 4 149040160 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs1403142 4 149042293 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs1403143 4 149042334 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6857011 4 149055437 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs17024404 4 149060307 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs11736161 4 149063275 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs12651282 4 149064158 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs2272089 4 149073555 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6844155 4 149081621 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs17024437 4 149081808 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6810951 4 149084112 [T/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6856803 4 149087127 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6535584 4 149090088 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs4835490 4 149090326 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs10519942 4 149098559 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs17024456 4 149100252 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs11099681 4 149103454 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs3910054 4 149116534 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs3846302 4 149117955 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs3846306 4 149131264 [T/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6535594 4 149132756 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs7699349 4 149134594 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs10050229 4 149135547 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs17483979 4 149136414 [A/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs3857080 4 149136440 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs13116347 4 149139067 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs12641471 4 149139764 [A/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs3910044 4 149147823 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs2883917 4 149148578 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs982076 4 149157085 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs3846313 4 149159119 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs17484063 4 149164905 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs3846317 4 149165351 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs3846318 4 149165388 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs3846321 4 149166943 [A/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs3846322 4 149173629 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6855341 4 149183374 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6836191 4 149188327 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6812904 4 149196991 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs17484357 4 149198415 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs10012553 4 149198522 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs3846323 4 149203945 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs17484454 4 149209008 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs3910047 4 149210677 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs13147775 4 149215821 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs2883929 4 149221110 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs3846329 4 149229338 [T/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs10434128 4 149245293 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6828378 4 149247040 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6851669 4 149251809 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6826213 4 149251850 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs3920217 4 149254723 [T/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs1546531 4 149264255 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs1546529 4 149264399 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs17024631 4 149264663 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs2137335 4 149265166 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs10034789 4 149265483 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs17484671 4 149268136 [T/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs17484678 4 149268146 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs992556 4 149269636 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs2063555 4 149284080 [A/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs2137330 4 149284425 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs10434100 4 149287807 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs13109808 4 149291532 [A/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs10519963 4 149297675 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs17581884 4 149299071 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs907620 4 149302984 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs878232 4 149303503 [T/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs11725509 4 149311728 [A/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6825048 4 149313238 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6831212 4 149313878 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs1490453 4 149321346 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs1512327 4 149322379 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs1913023 4 149324571 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6834935 4 149326597 [T/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs1512328 4 149330018 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs1994624 4 149330922 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs7698307 4 149332071 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs17024708 4 149340536 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs2048546 4 149342487 [A/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs10026568 4 149347854 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs4635799 4 149350527 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs2172002 4 149352962 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs5529 4 149356300 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 EXON Synonymous_S571S,Synonymous_S571S,Silent,Synonymous_S571S rs5527 4 149356352 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 EXON Missense_N554S,Missense_N554S,Silent,Missense_N554S rs5522 4 149357475 [T/C] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 EXON Missense_V180I,Missense_V180I,Silent,Missense_V180I rs7658048 4 149362744 [A/G] NM_000901,NM_001166104,NR_148974,NM_001354819 NR3C2,NR3C2,NR3C2,NR3C2 Silent,Silent,Silent,Silent rs6535611 4 149379537 [A/G] rs6535612 4 149384030 [T/C] rs1490463 4 149386704 [T/C] rs6829183 4 149393131 [A/G] rs1472061 4 149398778 [A/G] rs4324532 4 149403565 [T/G] rs17485372 4 149425641 [A/G] rs2200984 4 149435731 [T/C] rs875758 4 149447366 [A/G] rs13123270 4 149461969 [A/G] rs1032328 4 149463102 [T/C] rs902409 4 149463931 [T/C] rs17024762 4 149464531 [A/G] rs2130644 4 149469901 [A/G] rs931446 4 149475748 [T/G] rs6844135 4 149479886 [T/C] rs17582746 4 149493193 [A/G] rs13118340 4 149507299 [T/C] rs4475130 4 149522696 [T/G] rs12644824 4 149525713 [T/C] rs12644406 4 149537415 [A/G] rs6838226 4 149554651 [A/G] rs4835529 4 149555789 [T/G] rs11946746 4 149560804 [A/G] rs17582780 4 149562277 [T/C] rs17582787 4 149562638 [A/G] rs10452224 4 149570069 [A/G] rs7437928 4 149574788 [T/C] rs2358469 4 149590581 [A/G] rs4365706 4 149594489 [A/G] rs6821426 4 149596272 [T/C] rs6840553 4 149598573 [T/C] rs6840754 4 149598635 [T/G] rs17024901 4 149600181 [A/C] rs1316785 4 149601351 [T/C] rs7657765 4 149604264 [T/C] rs6826228 4 149605569 [A/G] rs6826460 4 149605653 [A/G] rs7666326 4 149614024 [T/C] rs4835530 4 149616993 [T/C] rs7674926 4 149619238 [A/G] rs13137679 4 149619375 [A/G] rs17024943 4 149621533 [T/G] rs17008423 4 149624705 [T/C] rs10008892 4 149625757 [A/C] rs10519980 4 149635025 [T/C] rs4835531 4 149636215 [A/G] rs7682301 4 149637571 [A/G] rs2358649 4 149641824 [A/C] rs7681551 4 149643143 [A/G] rs17583283 4 149648035 [A/G] rs17025017 4 149650033 [A/G] rs11935941 4 149652478 [A/C] rs11945082 4 149652582 [T/C] rs7677940 4 149654577 [A/G] rs17025162 4 149690361 [T/C] rs549653 4 149692497 [T/C] rs6848368 4 149697086 [A/C] rs558244 4 149700674 [A/G] rs7667838 4 149705772 [T/C] rs578668 4 149709259 [T/C] rs495515 4 149710794 [A/G] rs10519990 4 149712041 [A/C] rs517151 4 149712613 [A/G] rs2204206 4 149713872 [T/C] rs13134311 4 149724882 [A/C] rs525368 4 149729151 [A/G] rs4835145 4 149733616 [A/G] rs486116 4 149733739 [A/G] rs559072 4 149734385 [A/G] rs17487044 4 149736293 [A/G] rs4282147 4 149742079 [T/C] rs11099710 4 149742690 [A/G] rs552274 4 149743531 [A/G] rs17623254 4 149744201 [A/C] rs471967 4 149744518 [T/C] rs6854659 4 149750527 [T/G] rs9307850 4 149762698 [T/C] rs853721 4 149765628 [T/C] rs862657 4 149771033 [T/C] rs12498869 4 149771314 [T/C] rs17778070 4 149772371 [T/C] rs17025332 4 149773642 [A/G] rs1357440 4 149774113 [A/G] rs1634070 4 149775941 [T/C] rs10003214 4 149794284 [T/C] rs886148 4 149802894 [A/G] rs2520496 4 149817052 [A/G] rs1010178 4 149832511 [T/C] rs12374234 4 149841708 [T/C] rs12233660 4 149846648 [T/C] rs6535646 4 149871390 [A/C] rs17025520 4 149872845 [A/G] rs12644174 4 149878147 [A/G] rs13129108 4 149894321 [T/G] rs724043 4 149901085 [T/G] rs10489052 4 149902599 [T/G] rs756862 4 149903798 [A/G] rs17025566 4 149903982 [T/C] rs2520490 4 149911469 [A/G] rs7691878 4 149920515 [A/C] rs17025587 4 149921140 [T/C] rs2520494 4 149929686 [T/C] rs17025612 4 149933235 [A/G] rs10001495 4 149936868 [A/G] rs6839286 4 149943840 [A/G] rs6824983 4 149948850 [T/G] rs11946353 4 149954364 [T/C] rs6835961 4 149976613 [T/C] rs7673586 4 149979341 [A/G] rs10434101 4 150009235 [T/C] rs10021342 4 150031952 [T/G] rs1438768 4 150060844 [T/C] rs4522846 4 150070596 [T/C] rs6842668 4 150074544 [A/G] rs979227 4 150089373 [T/C] NR_125887 LINC02355 Silent rs1438781 4 150092178 [A/G] NR_125887 LINC02355 Silent rs10222969 4 150103438 [T/G] NR_125887 LINC02355 Silent rs13435568 4 150107863 [T/C] NR_125887 LINC02355 Silent rs11099718 4 150108607 [T/C] NR_125887 LINC02355 Silent rs7679738 4 150122796 [T/C] NR_125887 LINC02355 Silent rs10520008 4 150122817 [T/C] NR_125887 LINC02355 Silent rs562329 4 150129324 [T/C] NR_125887 LINC02355 Silent rs564115 4 150129495 [T/C] NR_125887 LINC02355 Silent rs1438765 4 150129861 [T/C] NR_125887 LINC02355 Silent rs17025936 4 150135657 [A/G] NR_125887 LINC02355 EXON Silent rs11721563 4 150156579 [A/C] NR_125887 LINC02355 Silent rs6828493 4 150167413 [T/C] NR_125887 LINC02355 Silent rs17025973 4 150168192 [T/C] NR_125887 LINC02355 Silent rs1438792 4 150175021 [A/G] NR_125887 LINC02355 Silent rs580399 4 150178430 [A/G] NR_125887 LINC02355 Silent rs17026020 4 150181175 [T/C] NR_125887 LINC02355 EXON Silent rs3106916 4 150181884 [A/G] NR_125887 LINC02355 Silent rs3106921 4 150184393 [A/G] NR_125887 LINC02355 Silent rs546978 4 150200706 [A/G] rs17026072 4 150202270 [A/G] rs4835570 4 150202672 [T/C] rs9307855 4 150205408 [A/C] rs538844 4 150208355 [T/C] rs13124924 4 150233544 [T/C] rs7668712 4 150242751 [A/G] rs2359333 4 150253761 [T/C] rs6535675 4 150267639 [T/C] rs17624486 4 150280975 [T/C] NM_001363507 IQCM Silent rs8180206 4 150283932 [T/C] NM_001363507 IQCM Silent rs7653957 4 150288111 [A/G] NM_001363507 IQCM Silent rs17026194 4 150325401 [A/G] NM_001363507 IQCM Silent rs17026209 4 150333440 [A/G] NM_001363507 IQCM Silent rs17026271 4 150386247 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs17026275 4 150410052 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs17624848 4 150419759 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs13144096 4 150433523 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs1394028 4 150457508 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs10019047 4 150459436 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs2654804 4 150473832 [A/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs11099736 4 150479466 [A/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs17625032 4 150480129 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs1503697 4 150486553 [A/G] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs6814124 4 150554591 [A/G] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs17625197 4 150572890 [A/G] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs6835299 4 150585534 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs6835892 4 150585770 [A/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs7659523 4 150613311 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs17687220 4 150616733 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs1394048 4 150632186 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs1354363 4 150632409 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs905576 4 150634191 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs7684095 4 150646588 [A/G] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs6832401 4 150648381 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs17502597 4 150655652 [A/G] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs1394050 4 150659552 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs7673358 4 150662409 [A/G] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs17026425 4 150672514 [A/G] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs10021126 4 150678416 [A/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs1394843 4 150684793 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs17631073 4 150688687 [A/G] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs1503748 4 150690457 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs17687541 4 150692380 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs1876069 4 150711342 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs1566801 4 150712561 [A/G] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs1394845 4 150712923 [A/G] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs17026442 4 150714094 [T/C] NM_001363507,NM_001363509 IQCM,IQCM Silent,Silent rs4835597 4 150737037 [T/C] rs11936885 4 150741301 [T/C] rs6849686 4 150756808 [T/G] rs17631265 4 150766017 [T/C] rs10008520 4 150792331 [T/C] rs7655916 4 150798489 [T/C] rs6852150 4 150818662 [A/G] rs12642812 4 150827830 [A/G] rs17687953 4 150831292 [A/G] rs4835604 4 150844720 [T/C] rs6830133 4 150845428 [A/G] rs10034539 4 150848340 [A/C] rs1505469 4 150848576 [A/G] rs6811032 4 150850281 [A/G] rs2359925 4 150852139 [A/G] rs905900 4 150852782 [A/G] rs17631619 4 150853668 [T/G] rs17587757 4 150854267 [A/G] rs1505473 4 150854889 [A/G] rs11726953 4 150856693 [T/C] rs1505474 4 150858865 [T/G] rs17631722 4 150862026 [T/C] rs4493520 4 150878634 [T/G] rs12642120 4 150884878 [A/G] rs4631018 4 150892490 [T/C] rs9759379 4 150901440 [A/G] rs11930273 4 150901757 [A/G] rs10034329 4 150902638 [T/C] rs11099749 4 150904037 [T/G] rs10002187 4 150915414 [A/G] rs3923657 4 150918798 [T/C] rs6535702 4 150919730 [T/C] rs4501203 4 150924437 [A/G] rs4312736 4 150935520 [T/C] rs4317185 4 150946383 [A/G] rs6833562 4 150951692 [T/C] rs4634199 4 150954229 [A/G] rs7655571 4 150955500 [T/C] rs10857241 4 150960142 [A/G] rs10017432 4 150960542 [A/G] rs13130722 4 150968276 [T/C] rs4835616 4 150974325 [A/G] rs4835617 4 150976000 [A/G] rs4423856 4 150984857 [T/C] rs4270569 4 150995468 [A/C] rs6818273 4 150997068 [A/G] rs11099754 4 151005404 [T/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs9307865 4 151005467 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs6858003 4 151030964 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs4274825 4 151047967 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs12506111 4 151049574 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs7667342 4 151050375 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs4438743 4 151053158 [T/C] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs10857243 4 151063849 [T/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs11099756 4 151063917 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs4240358 4 151070611 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs7340876 4 151080475 [T/C] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs4240359 4 151082561 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs9683765 4 151091007 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs6535715 4 151101413 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs10520059 4 151103731 [T/C] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs7658837 4 151117651 [T/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs1124359 4 151119353 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs2359926 4 151122999 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs12374344 4 151126725 [T/C] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs7672325 4 151128741 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs17631799 4 151133778 [T/C] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs7679888 4 151144170 [T/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs1459744 4 151157195 [T/C] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs1459748 4 151158031 [T/C] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs6535725 4 151158952 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs6812795 4 151161342 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs11931842 4 151161470 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs1993656 4 151164724 [T/C] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs1531335 4 151166237 [T/C] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs12501888 4 151168711 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs2359940 4 151168929 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs1459750 4 151170387 [A/G] NM_001040260,NM_001040261,NR_036614 DCLK2,DCLK2,DCLK2 Silent,Silent,Silent rs6844989 4 151182255 [T/C] rs11059 4 151185651 [A/C] NM_001364905 LRBA EXON Silent rs1599167 4 151188215 [T/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs13134607 4 151190804 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs2290846 4 151199080 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA EXON Missense_S2798L,Missense_S2809L,Missense_S2797L rs11099759 4 151202952 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs11944163 4 151204693 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs3749574 4 151207127 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA EXON Missense_A2693T,Missense_A2704T,Missense_A2692T rs7657457 4 151210761 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs10007367 4 151214038 [T/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs4696254 4 151216870 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs1960918 4 151222266 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs11734677 4 151229489 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs1813134 4 151231371 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs13151875 4 151233934 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs962626 4 151238436 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs17588629 4 151252297 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs17588741 4 151271758 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs11945847 4 151272102 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs13136928 4 151275634 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs4458434 4 151275797 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs17026840 4 151279717 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs7657948 4 151284982 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs7693658 4 151292110 [T/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs7699001 4 151301638 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs6823402 4 151303851 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs6848343 4 151312761 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs11736546 4 151331191 [A/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs7686589 4 151337243 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs1979920 4 151343482 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs1504782 4 151346422 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs7689850 4 151349664 [T/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs4696352 4 151356081 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs7698239 4 151368816 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs11733926 4 151369107 [T/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs10471055 4 151372589 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs11727758 4 151376718 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs1875899 4 151385976 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs1504781 4 151388101 [T/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs2036552 4 151397759 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs4696435 4 151399246 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs7688410 4 151403684 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs1504786 4 151406414 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs13102532 4 151413637 [T/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs7688842 4 151420304 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs11931161 4 151444619 [T/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs11931175 4 151444833 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs13150736 4 151446347 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs952225 4 151454015 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs7699621 4 151470988 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs12649589 4 151479467 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs17026968 4 151489677 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs17589398 4 151496759 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs10022844 4 151499440 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs9993229 4 151502267 [A/G] NM_001364905,NM_006726,NM_001199282,NR_149035 LRBA,LRBA,LRBA,LOC729558 EXON Silent,Silent,Silent,Silent rs4435730 4 151519232 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs9999828 4 151534545 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs6847725 4 151547243 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs10010950 4 151574839 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs10026518 4 151588483 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs4318628 4 151602118 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs4455394 4 151625361 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs10857249 4 151632108 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs17027030 4 151637154 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs6535746 4 151637268 [A/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs7690485 4 151659605 [T/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs13147122 4 151662114 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs1451634 4 151665097 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs6835805 4 151694950 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs716473 4 151730224 [A/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs716474 4 151730255 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs294534 4 151740574 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs6846361 4 151761599 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs186080 4 151765243 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs10012720 4 151772410 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs1782360 4 151773593 [G/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA EXON Missense_A1090G,Missense_A1090G,Missense_A1090G rs2407549 4 151790540 [A/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs17027158 4 151794207 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs1201214 4 151815783 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs1201208 4 151829824 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA EXON Synonymous_A449A,Synonymous_A449A,Synonymous_A449A rs1201201 4 151840850 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs1148642 4 151852107 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs1201198 4 151859674 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs17027211 4 151863847 [T/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs9992474 4 151880765 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs6839352 4 151887280 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs2081606 4 151901433 [A/G] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs17027240 4 151918331 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs7665597 4 151936149 [T/C] NM_001364905,NM_006726,NM_001199282 LRBA,LRBA,LRBA Silent,Silent,Silent rs4696648 4 151948111 [A/G] rs6819599 4 151978131 [T/C] rs7697992 4 151998622 [T/G] rs12647989 4 152000891 [A/G] rs13145829 4 152014653 [A/G] rs11733964 4 152015704 [T/C] rs13101417 4 152015776 [T/C] rs2897659 4 152016931 [T/C] rs4696226 4 152020229 [T/C] rs2280283 4 152020777 [T/C] NM_001006,NM_001267699 RPS3A,RPS3A EXON Silent,Silent rs28523454 4 152024637 [A/G] NM_001006,NM_001267699 RPS3A,RPS3A EXON Silent,Silent rs10016856 4 152034435 [A/G] rs28399915 4 152039964 [T/G] rs7659146 4 152053302 [A/G] NM_001128923,NM_001009555,NM_001243349,NM_001128924 SH3D19,SH3D19,SH3D19,SH3D19 Silent,Silent,Silent,Silent rs11938266 4 152055073 [T/C] NM_001128923,NM_001009555,NM_001243349,NM_001128924 SH3D19,SH3D19,SH3D19,SH3D19 Silent,Silent,Silent,Silent rs3736502 4 152065197 [T/C] NM_001128923,NM_001009555,NM_001243349,NM_001128924 SH3D19,SH3D19,SH3D19,SH3D19 EXON Synonymous_G416G,Synonymous_G439G,Synonymous_G416G,Synonymous_G380G rs6818900 4 152065684 [A/G] NM_001128923,NM_001009555,NM_001243349,NM_001128924 SH3D19,SH3D19,SH3D19,SH3D19 Silent,Silent,Silent,Silent rs7669180 4 152066906 [A/C] NM_001128923,NM_001009555,NM_001243349,NM_001128924 SH3D19,SH3D19,SH3D19,SH3D19 Silent,Silent,Silent,Silent rs11734586 4 152095256 [T/C] NM_001128923,NM_001009555,NM_001243349,NM_001128924 SH3D19,SH3D19,SH3D19,SH3D19 Silent,Silent,Silent,Silent rs17505733 4 152096755 [T/C] NM_001128923,NM_001009555,NM_001243349 SH3D19,SH3D19,SH3D19 EXON Silent,Silent,Silent rs11934792 4 152097962 [T/C] NM_001128923,NM_001009555,NM_001243349 SH3D19,SH3D19,SH3D19 Silent,Silent,Silent rs12647306 4 152105400 [A/G] NM_001128923,NM_001009555,NM_001243349 SH3D19,SH3D19,SH3D19 Silent,Silent,Silent rs13120989 4 152109552 [T/G] NM_001128923,NM_001009555,NM_001243349 SH3D19,SH3D19,SH3D19 Silent,Silent,Silent rs12508270 4 152114234 [T/C] NM_001128923,NM_001009555,NM_001243349 SH3D19,SH3D19,SH3D19 Silent,Silent,Silent rs2407406 4 152144869 [A/G] NM_001128923,NM_001009555,NM_001243349 SH3D19,SH3D19,SH3D19 Silent,Silent,Silent rs10520101 4 152147262 [A/G] NM_001128923,NM_001009555,NM_001243349 SH3D19,SH3D19,SH3D19 Silent,Silent,Silent rs10520102 4 152147441 [A/G] NM_001128923,NM_001009555,NM_001243349 SH3D19,SH3D19,SH3D19 EXON Silent,Silent,Silent rs17633648 4 152158519 [T/C] rs12509302 4 152164786 [A/G] rs2407167 4 152172980 [A/C] rs7663659 4 152175168 [T/C] rs10520104 4 152179311 [T/C] rs10016704 4 152192808 [A/G] rs6832423 4 152196052 [T/G] rs6832149 4 152196218 [A/G] rs10031902 4 152197483 [A/C] rs1875308 4 152201204 [A/G] NM_001353611,NM_183375 PRSS48,PRSS48 Silent,Silent rs13112985 4 152205278 [A/G] NM_001353611,NM_183375 PRSS48,PRSS48 Silent,Silent rs13126069 4 152212486 [T/C] NM_001353611,NM_183375 PRSS48,PRSS48 EXON Missense_R290C,Missense_R290C rs11734518 4 152213113 [A/G] rs6852223 4 152221451 [A/G] rs6535787 4 152227582 [T/C] rs17690584 4 152228983 [T/C] rs11935905 4 152229767 [T/C] rs12646254 4 152234938 [A/G] rs17590964 4 152235761 [A/G] rs2407171 4 152256782 [A/G] rs10033020 4 152280646 [A/G] rs6535791 4 152294729 [A/G] rs6535797 4 152306809 [A/G] rs2724553 4 152321881 [T/C] rs2709828 4 152355268 [T/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs11938851 4 152374502 [A/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs6845067 4 152375803 [T/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs11941136 4 152379820 [T/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs11732407 4 152401909 [A/G] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs17027640 4 152417635 [A/G] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs11947054 4 152428258 [T/G] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs1443088 4 152450126 [A/G] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs1946999 4 152455339 [T/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs11946622 4 152486018 [T/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs7695412 4 152488075 [A/G] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs17275536 4 152498625 [T/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 EXON Synonymous_H43H,Synonymous_H43H rs1473305 4 152511721 [T/G] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs17275584 4 152523327 [A/G] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs6825241 4 152543783 [A/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs12651635 4 152557786 [T/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs9631757 4 152567239 [A/G] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs17275598 4 152568478 [A/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs12509425 4 152569864 [T/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs10014639 4 152570535 [A/G] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs7699787 4 152575079 [T/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs13353741 4 152578102 [T/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 Silent,Silent rs6843755 4 152586594 [A/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 EXON Silent,Silent rs1366910 4 152588541 [T/C] NM_001109977,NM_001348694 FAM160A1,FAM160A1 EXON Silent,Silent rs17027780 4 152590337 [T/G] NM_001109977,NM_001348694 FAM160A1,FAM160A1 EXON Silent,Silent rs4571 4 152592191 [T/C] NM_001363341,NM_004564 GATB,GATB EXON Silent,Silent rs3749563 4 152596508 [T/C] NM_001363341,NM_004564 GATB,GATB Silent,Silent rs7669761 4 152609304 [A/G] NM_001363341,NM_004564 GATB,GATB Silent,Silent rs6833277 4 152610318 [T/C] NM_001363341,NM_004564 GATB,GATB Silent,Silent rs9996600 4 152610894 [T/C] NM_001363341,NM_004564 GATB,GATB Silent,Silent rs4696288 4 152621150 [A/C] NM_001363341,NM_004564 GATB,GATB Silent,Silent rs907238 4 152623285 [T/C] NM_001363341,NM_004564 GATB,GATB Silent,Silent rs11732441 4 152625446 [A/G] NM_001363341,NM_004564 GATB,GATB Silent,Silent rs4696290 4 152631472 [A/G] NM_001363341,NM_004564 GATB,GATB Silent,Silent rs6832872 4 152640305 [A/G] NM_001363341,NM_004564 GATB,GATB Silent,Silent rs6535818 4 152650882 [T/G] NM_001363341,NM_004564 GATB,GATB Silent,Silent rs7684350 4 152672882 [T/G] NM_001363341,NM_004564 GATB,GATB Silent,Silent rs17275724 4 152677580 [T/C] NM_001363341,NM_004564 GATB,GATB Silent,Silent rs1429559 4 152681952 [A/G] NM_001363341,NM_004564 GATB,GATB Silent,Silent rs3762906 4 152682805 [T/C] rs2048433 4 152701085 [T/G] rs2175409 4 152701656 [T/C] rs13137669 4 152710943 [T/C] rs11099829 4 152727299 [T/C] rs6846809 4 152730201 [A/G] rs2136959 4 152740233 [A/G] rs17027878 4 152744583 [A/G] rs2136961 4 152746079 [A/G] rs1397684 4 152752413 [T/G] rs361191 4 152761633 [T/G] rs361197 4 152763556 [A/G] rs6843959 4 152764822 [T/C] rs361099 4 152773713 [T/C] rs6835546 4 152776271 [T/C] rs361210 4 152777262 [A/G] rs17027947 4 152778691 [T/C] rs7657092 4 152779838 [T/C] rs17027958 4 152782639 [T/C] rs488400 4 152782878 [T/G] rs1682083 4 152784064 [T/G] rs1872513 4 152784669 [T/C] rs165581 4 152789786 [A/G] rs17027997 4 152790580 [A/G] rs361167 4 152790628 [A/G] rs17028004 4 152791654 [A/G] rs13145151 4 152792546 [T/G] rs361166 4 152792791 [A/G] rs361163 4 152799883 [A/G] rs715947 4 152801922 [A/C] rs901207 4 152804140 [T/C] rs11723144 4 152807559 [A/G] rs4696302 4 152813118 [A/G] rs361139 4 152818704 [A/G] rs569802 4 152825600 [A/G] rs499797 4 152826032 [A/C] rs360919 4 152832903 [A/G] rs10517561 4 152833119 [T/C] rs10026217 4 152836388 [T/C] rs2020009 4 152837454 [T/C] rs361110 4 152841392 [A/G] rs10028709 4 152845946 [A/C] rs360936 4 152846749 [A/C] rs1631928 4 152851437 [A/G] rs7658783 4 152852199 [T/C] rs189672 4 152854159 [T/C] rs360939 4 152854578 [A/C] rs19412 4 152855624 [A/G] rs165579 4 152861685 [T/C] rs12645594 4 152872349 [T/C] rs6837639 4 152872859 [T/C] rs360951 4 152875259 [A/G] rs6845076 4 152880827 [A/C] rs360915 4 152887879 [T/C] rs17360838 4 152889046 [A/C] rs168629 4 152895947 [A/G] rs975820 4 152899554 [T/C] rs6535830 4 152900692 [A/G] rs360928 4 152907581 [A/G] rs6852759 4 152912247 [A/C] rs10857265 4 152914614 [T/C] rs1364870 4 152919913 [A/G] rs750090 4 152931436 [T/C] rs10015937 4 152933610 [T/C] rs4696124 4 152935555 [T/G] rs17028387 4 152936693 [T/G] rs17028403 4 152943626 [A/G] rs17028407 4 152944433 [A/C] rs7667919 4 152945315 [A/G] rs11099839 4 152947155 [T/C] rs12505581 4 152948812 [A/G] rs17028431 4 152949686 [A/G] rs7664595 4 152957069 [A/G] rs12511908 4 152957388 [A/G] rs13149643 4 152958338 [A/G] rs17276212 4 152958691 [T/C] rs1559695 4 152962166 [T/C] rs7655280 4 152967911 [A/C] rs6842274 4 152980406 [A/G] rs16998854 4 152983232 [T/C] rs1425397 4 152984315 [A/G] rs10032875 4 152984540 [T/C] rs17028523 4 152986716 [T/G] rs11737270 4 152988228 [A/G] rs17028539 4 152991734 [T/C] rs17028543 4 152991825 [T/C] rs4696128 4 152992266 [T/C] rs17361055 4 152994226 [T/C] rs10013460 4 153001299 [T/G] rs1318845 4 153001662 [T/C] rs4696314 4 153005716 [T/C] rs6829453 4 153007226 [T/C] rs7659540 4 153008540 [T/C] rs6535835 4 153010765 [A/G] rs9992175 4 153012499 [A/G] rs17361160 4 153016797 [T/C] rs747110 4 153017452 [A/G] rs13140099 4 153022375 [A/G] NR_121628,NR_121627 LINC02273,LINC02273 Silent,Silent rs6535838 4 153023402 [A/C] NR_121628,NR_121627 LINC02273,LINC02273 Silent,Silent rs17361216 4 153029463 [A/G] rs13147317 4 153030658 [A/G] rs10517562 4 153035743 [A/G] rs13107968 4 153037671 [T/C] rs13126953 4 153055930 [A/G] rs7682931 4 153060217 [A/G] rs6823091 4 153069783 [A/C] rs11727862 4 153075234 [A/G] rs6535843 4 153086567 [A/G] rs6849420 4 153090442 [T/C] rs2897464 4 153091323 [A/C] rs2001705 4 153092536 [T/C] rs4466023 4 153093492 [A/G] rs6858503 4 153095684 [T/C] rs17361412 4 153097096 [T/C] rs11732677 4 153100692 [T/C] rs13119810 4 153109365 [T/C] rs13127295 4 153110256 [A/G] rs13109486 4 153111134 [T/C] rs6856727 4 153121818 [T/G] rs12513336 4 153124691 [T/C] rs11727661 4 153134959 [A/C] rs11728805 4 153135952 [T/C] rs11737308 4 153136602 [A/C] rs3749541 4 153143877 [T/C] rs6847949 4 153149284 [A/G] rs6856075 4 153151602 [T/C] rs6810751 4 153156044 [A/G] rs6836275 4 153156200 [T/C] rs2406624 4 153162845 [A/C] rs4554046 4 153167171 [A/G] rs2406623 4 153184316 [A/G] rs10517563 4 153188678 [T/C] rs17276827 4 153195089 [A/G] rs3923993 4 153206597 [T/C] rs6838430 4 153211026 [A/G] rs4416456 4 153219231 [T/G] rs17276848 4 153220331 [T/G] rs7678272 4 153229868 [A/G] rs35260882 4 153245269 [A/G] NM_018315,NM_001013415,NM_001349798,NM_033632 FBXW7,FBXW7,FBXW7,FBXW7 Silent,Silent,Silent,Silent rs10033601 4 153252061 [A/G] NM_018315,NM_001013415,NM_001349798,NM_033632 FBXW7,FBXW7,FBXW7,FBXW7 Silent,Silent,Silent,Silent rs2714803 4 153267968 [A/G] NM_018315,NM_001013415,NM_001349798,NM_033632 FBXW7,FBXW7,FBXW7,FBXW7 Silent,Silent,Silent,Silent rs17276861 4 153288835 [A/G] NM_001013415,NM_001349798,NM_033632 FBXW7,FBXW7,FBXW7 Silent,Silent,Silent rs2714805 4 153294875 [T/C] NM_001013415,NM_001349798,NM_033632 FBXW7,FBXW7,FBXW7 Silent,Silent,Silent rs17028858 4 153302754 [T/C] NM_001013415,NM_001349798,NM_033632 FBXW7,FBXW7,FBXW7 Silent,Silent,Silent rs10018285 4 153305544 [T/C] NM_001349798,NM_033632 FBXW7,FBXW7 Silent,Silent rs2255137 4 153309538 [T/C] NM_001349798,NM_033632 FBXW7,FBXW7 Silent,Silent rs4443256 4 153324787 [T/C] NM_001349798,NM_033632 FBXW7,FBXW7 Silent,Silent rs2676333 4 153329783 [T/G] NM_001349798,NM_033632 FBXW7,FBXW7 Silent,Silent rs12644477 4 153332380 [T/G] NM_001349798,NM_033632,NM_001257069 FBXW7,FBXW7,FBXW7 EXON Silent,Silent,Silent rs2676334 4 153340648 [A/C] NM_001349798,NM_033632,NM_001257069 FBXW7,FBXW7,FBXW7 Silent,Silent,Silent rs2676336 4 153353128 [T/C] NM_001349798,NM_033632,NM_001257069 FBXW7,FBXW7,FBXW7 Silent,Silent,Silent rs17028899 4 153363612 [T/C] NM_001349798,NM_033632,NM_001257069 FBXW7,FBXW7,FBXW7 Silent,Silent,Silent rs2628570 4 153373680 [T/G] NM_001349798,NM_033632,NM_001257069 FBXW7,FBXW7,FBXW7 Silent,Silent,Silent rs1516820 4 153380801 [T/C] NM_001349798,NM_033632,NM_001257069 FBXW7,FBXW7,FBXW7 Silent,Silent,Silent rs7682964 4 153388854 [T/C] NM_001349798,NM_033632,NM_001257069 FBXW7,FBXW7,FBXW7 Silent,Silent,Silent rs17028932 4 153415654 [T/C] NM_001349798,NM_033632,NM_001257069 FBXW7,FBXW7,FBXW7 Silent,Silent,Silent rs1484879 4 153455628 [A/G] NM_001349798,NM_033632,NM_001257069 FBXW7,FBXW7,FBXW7 Silent,Silent,Silent rs1351903 4 153456102 [A/G] NM_001349798,NM_033632,NM_001257069 FBXW7,FBXW7,FBXW7 EXON Silent,Silent,Silent rs1072789 4 153482738 [T/G] rs2054757 4 153485919 [A/G] rs10011174 4 153495515 [A/G] rs10020796 4 153519781 [T/C] rs7695877 4 153532240 [A/G] rs10032212 4 153537671 [T/C] rs6841598 4 153545990 [T/C] rs9685255 4 153546415 [A/C] rs3922934 4 153548037 [A/C] NM_152680 TMEM154 EXON Silent rs4696329 4 153554397 [A/G] NM_152680 TMEM154 Silent rs12642676 4 153557795 [T/C] NM_152680 TMEM154 Silent rs6813566 4 153558041 [A/C] NM_152680 TMEM154 Silent rs4696332 4 153559468 [T/C] NM_152680 TMEM154 Silent rs3935569 4 153565838 [T/C] NM_152680 TMEM154 Silent rs4443258 4 153565969 [T/C] NM_152680 TMEM154 Silent rs10034000 4 153569094 [T/C] NM_152680 TMEM154 Silent rs4508863 4 153571180 [A/G] NM_152680 TMEM154 Silent rs6849505 4 153573491 [T/C] NM_152680 TMEM154 Silent rs6814401 4 153575339 [A/G] NM_152680 TMEM154 Silent rs11721759 4 153583949 [A/G] NM_152680 TMEM154 Silent rs4437231 4 153586001 [T/G] NM_152680 TMEM154 Silent rs4447840 4 153588500 [A/G] NM_152680 TMEM154 Silent rs10010565 4 153590063 [A/C] NM_152680 TMEM154 Silent rs12650067 4 153601716 [A/G] rs6857876 4 153610164 [A/G] rs4513549 4 153626114 [T/C] rs13124365 4 153629791 [T/C] rs11930234 4 153635369 [T/C] rs4128306 4 153641782 [A/G] rs4696345 4 153644873 [A/G] rs4396973 4 153647078 [A/G] rs4077297 4 153656788 [T/C] rs7340869 4 153658324 [T/G] rs10003999 4 153658895 [T/C] rs10009955 4 153660407 [A/C] rs12500918 4 153669008 [A/C] rs4540026 4 153669404 [T/C] rs11732223 4 153681139 [A/G] rs11099852 4 153685314 [A/G] rs7674876 4 153688776 [T/C] rs6839340 4 153689963 [A/C] rs4359884 4 153695501 [T/C] NM_145720 TIGD4 Silent rs4276265 4 153695779 [T/C] NM_145720 TIGD4 Silent rs6850467 4 153696635 [T/C] NM_145720 TIGD4 Silent rs4619875 4 153701130 [T/C] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 EXON Silent,Silent,Silent,Silent,Silent,Silent rs10028182 4 153701640 [A/G] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 Silent,Silent,Silent,Silent,Silent,Silent rs11099853 4 153703306 [T/C] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 Silent,Silent,Silent,Silent,Silent,Silent rs7688908 4 153714157 [A/G] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 Silent,Silent,Silent,Silent,Silent,Silent rs7699456 4 153720692 [A/G] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 Silent,Silent,Silent,Silent,Silent,Silent rs6535875 4 153724039 [T/C] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 Silent,Silent,Silent,Silent,Silent,Silent rs7680002 4 153725000 [T/G] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 Silent,Silent,Silent,Silent,Silent,Silent rs28769919 4 153729627 [A/G] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 Silent,Silent,Silent,Silent,Silent,Silent rs4504228 4 153732359 [T/C] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 Silent,Silent,Silent,Silent,Silent,Silent rs10007643 4 153765098 [T/C] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 Silent,Silent,Silent,Silent,Silent,Silent rs13102607 4 153779819 [T/C] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 Silent,Silent,Silent,Silent,Silent,Silent rs10013266 4 153793179 [T/C] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 Silent,Silent,Silent,Silent,Silent,Silent rs7677801 4 153795067 [A/G] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 Silent,Silent,Silent,Silent,Silent,Silent rs4254753 4 153800029 [T/G] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 Silent,Silent,Silent,Silent,Silent,Silent rs7664303 4 153829996 [A/G] NM_001287433,NM_001287432,NM_001287431,NM_001025593,NM_001025595,NM_014447 ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1,ARFIP1 Silent,Silent,Silent,Silent,Silent,Silent rs2004794 4 153860134 [T/G] rs1474028 4 153863214 [T/G] rs12501601 4 153863430 [T/C] rs6836054 4 153872443 [T/C] NM_033393 FHDC1 Silent rs867322 4 153878480 [A/G] NM_033393 FHDC1 Silent rs11737767 4 153879878 [T/C] NM_033393 FHDC1 Silent rs3811834 4 153881835 [T/C] NM_033393 FHDC1 Silent rs2018007 4 153886104 [A/G] NM_033393 FHDC1 EXON Synonymous_L359L rs1018316 4 153888640 [T/C] NM_033393 FHDC1 Silent rs10008050 4 153890646 [T/C] NM_033393 FHDC1 Silent rs11099864 4 153893354 [A/G] NM_033393 FHDC1 Silent rs908526 4 153894243 [A/G] NM_033393 FHDC1 Silent rs6854393 4 153898166 [A/G] NM_033393 FHDC1 EXON Silent rs4696370 4 153898178 [A/G] NM_033393 FHDC1 EXON Silent rs1059354 4 153899573 [A/C] NM_033393 FHDC1 EXON Silent rs1059355 4 153899658 [T/C] NM_033393 FHDC1 EXON Silent rs908527 4 153900025 [A/G] NM_033393 FHDC1 EXON Silent rs7681249 4 153901275 [A/G] rs12512990 4 153902011 [A/C] rs6851633 4 153902939 [T/C] rs6535886 4 153903766 [A/G] rs7666138 4 153905686 [T/C] rs6844943 4 153909331 [T/C] rs13131114 4 153915003 [T/C] rs11931660 4 153916577 [A/G] rs13120414 4 153917822 [A/G] rs1878284 4 153919578 [A/C] rs12504106 4 153920579 [A/G] rs6811075 4 153928731 [A/G] rs6837953 4 153930963 [A/G] rs11731715 4 153934639 [A/C] rs4696379 4 153936488 [A/C] rs6535888 4 153938095 [T/C] rs11722167 4 153940203 [A/G] rs11723393 4 153941622 [A/C] rs11722890 4 153942865 [T/C] rs1533458 4 153943149 [A/G] rs6818398 4 153943571 [T/C] rs17029498 4 153945152 [A/G] rs17029499 4 153945320 [A/G] rs13138175 4 153946010 [T/C] rs6814889 4 153947145 [A/G] rs1111986 4 153949047 [A/G] rs2406136 4 153951159 [T/G] rs1607074 4 153957777 [T/C] rs17029520 4 153958198 [T/C] rs1516691 4 153958505 [A/C] rs1024148 4 153960368 [T/G] rs1516692 4 153963155 [A/C] rs908535 4 153968142 [A/G] rs10030391 4 153969414 [T/C] rs4696161 4 153970416 [A/C] rs4696164 4 153970964 [A/G] rs2056168 4 153977593 [A/G] rs12651351 4 153979941 [T/C] rs4696392 4 153980805 [T/C] rs6535893 4 153981236 [T/C] rs6832907 4 153982885 [A/G] rs7683508 4 153984283 [A/G] rs2090380 4 153986325 [A/G] rs6858521 4 153991639 [A/G] rs12641081 4 153999303 [A/G] rs4696394 4 154000240 [A/G] rs4696395 4 154000267 [T/C] rs4696396 4 154000968 [T/C] rs7691951 4 154003295 [T/C] rs1516684 4 154005032 [A/G] rs12648638 4 154006090 [T/G] rs7683638 4 154008453 [A/G] rs12651091 4 154008962 [T/C] rs13112096 4 154011656 [A/G] rs1878285 4 154012751 [T/G] rs2406241 4 154012784 [A/G] rs4696402 4 154014175 [T/C] rs13130102 4 154015564 [T/C] rs4696404 4 154016744 [A/G] rs17029682 4 154016973 [A/G] rs4696406 4 154017144 [T/G] rs2176304 4 154017805 [T/C] rs7662116 4 154017964 [A/C] rs1516689 4 154020068 [A/G] rs1588982 4 154022065 [T/C] rs12186209 4 154026613 [T/G] rs11725217 4 154035960 [A/C] rs6849116 4 154040215 [T/C] rs4696422 4 154040386 [T/G] rs10032068 4 154044043 [A/G] rs4323085 4 154053258 [A/C] rs10001638 4 154055176 [T/C] rs880972 4 154058319 [T/C] rs4075881 4 154066142 [A/C] rs4075879 4 154066319 [T/C] rs34205168 4 154075881 [T/C] NM_001351056,NM_001130067 TRIM2,TRIM2 Silent,Silent rs6817112 4 154080813 [T/C] NM_001351056,NM_001130067 TRIM2,TRIM2 Silent,Silent rs4696428 4 154087520 [T/C] NM_001351056,NM_001130067 TRIM2,TRIM2 Silent,Silent rs4696433 4 154087943 [A/G] NM_001351056,NM_001130067 TRIM2,TRIM2 Silent,Silent rs10023596 4 154094001 [A/G] NM_001351056,NM_001130067 TRIM2,TRIM2 Silent,Silent rs6535904 4 154110795 [A/G] NM_001351056,NM_001130067 TRIM2,TRIM2 Silent,Silent rs6817587 4 154118168 [A/G] NM_001351056,NM_001130067 TRIM2,TRIM2 Silent,Silent rs10023780 4 154124278 [A/G] NM_001351056,NM_001130067 TRIM2,TRIM2 Silent,Silent rs10019436 4 154125998 [T/C] NM_001351056,NM_001130067,NM_001302692,NM_015271,NM_001351057,NM_001302693 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs9997214 4 154135457 [A/G] NM_001351056,NM_001130067,NM_001302692,NM_015271,NM_001351057,NM_001302693 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs7686229 4 154135588 [T/C] NM_001351056,NM_001130067,NM_001302692,NM_015271,NM_001351057,NM_001302693 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs6535908 4 154138086 [A/G] NM_001351056,NM_001130067,NM_001302692,NM_015271,NM_001351057,NM_001302693 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs11723584 4 154138758 [T/C] NM_001351056,NM_001130067,NM_001302692,NM_015271,NM_001351057,NM_001302693 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs7687844 4 154139583 [A/C] NM_001351056,NM_001130067,NM_001302692,NM_015271,NM_001351057,NM_001302693 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs4696443 4 154151988 [A/G] NM_001351056,NM_001130067,NM_001302692,NM_015271,NM_001351057,NM_001302693 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs4596222 4 154155013 [A/G] NM_001351056,NM_001130067,NM_001302692,NM_015271,NM_001351057,NM_001302693 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs6813648 4 154159547 [A/G] NM_001351056,NM_001130067,NM_001302692,NM_015271,NM_001351057,NM_001302693 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs4696175 4 154159965 [T/C] NM_001351056,NM_001130067,NM_001302692,NM_015271,NM_001351057,NM_001302693 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs10009522 4 154163394 [T/C] NM_001351056,NM_001130067,NM_001302692,NM_015271,NM_001351057,NM_001302693 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs10033643 4 154176379 [T/C] NM_001351056,NM_001130067,NM_001302692,NM_015271,NM_001351057,NM_001302693 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs1470104 4 154191710 [A/G] NM_001351056,NM_001130067,NM_001302692,NM_015271,NM_001351057,NM_001302693,NM_001351055,NM_001351054,NM_001302694 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6833828 4 154196082 [A/G] NM_001351056,NM_001130067,NM_001302692,NM_015271,NM_001351057,NM_001302693,NM_001351055,NM_001351054,NM_001302694 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1455840 4 154200320 [A/G] NM_001351056,NM_001130067,NM_015271,NM_001351057,NM_001351055,NM_001351054 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs1455841 4 154200347 [A/G] NM_001351056,NM_001130067,NM_015271,NM_001351057,NM_001351055,NM_001351054 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs7690141 4 154212189 [T/C] NM_001351056,NM_001130067,NM_015271,NM_001351057,NM_001351055,NM_001351054 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs893805 4 154216710 [A/G] NM_001351056,NM_001130067,NM_015271,NM_001351057,NM_001351055,NM_001351054 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 EXON Synonymous_T317T,Synonymous_T317T,Synonymous_T344T,Synonymous_T192T,Synonymous_T334T,Synonymous_T335T rs2033880 4 154232522 [A/C] NM_001351056,NM_001130067,NM_015271,NM_001351057,NM_001351055,NM_001351054 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs961358 4 154240476 [A/G] NM_001351056,NM_001130067,NM_015271,NM_001351057,NM_001351055,NM_001351054 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs17029874 4 154244315 [A/G] NM_001351056,NM_001130067,NM_015271,NM_001351057,NM_001351055,NM_001351054 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs10517569 4 154244953 [T/C] NM_001351056,NM_001130067,NM_015271,NM_001351057,NM_001351055,NM_001351054 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs9991887 4 154246265 [A/G] NM_001351056,NM_001130067,NM_015271,NM_001351057,NM_001351055,NM_001351054 TRIM2,TRIM2,TRIM2,TRIM2,TRIM2,TRIM2 Silent,Silent,Silent,Silent,Silent,Silent rs6838185 4 154262299 [A/G] rs6535914 4 154262551 [T/C] rs10025256 4 154265347 [A/C] rs6841435 4 154274664 [T/C] NM_001253861,NR_045605,NM_032117 MND1,MND1,MND1 Silent,Silent,Silent rs13132311 4 154283051 [A/G] NM_001253861,NR_045605,NM_032117 MND1,MND1,MND1 Silent,Silent,Silent rs17029903 4 154284935 [A/G] NM_001253861,NR_045605,NM_032117 MND1,MND1,MND1 Silent,Silent,Silent rs17029907 4 154288126 [A/G] NM_001253861,NR_045605,NM_032117 MND1,MND1,MND1 Silent,Silent,Silent rs12499126 4 154292316 [A/G] NM_001253861,NR_045605,NM_032117 MND1,MND1,MND1 Silent,Silent,Silent rs4597810 4 154295116 [A/C] NM_001253861,NR_045605,NM_032117 MND1,MND1,MND1 Silent,Silent,Silent rs12503471 4 154296368 [T/G] NM_001253861,NR_045605,NM_032117 MND1,MND1,MND1 Silent,Silent,Silent rs7699617 4 154299829 [T/C] NM_001253861,NR_045605,NM_032117 MND1,MND1,MND1 Silent,Silent,Silent rs10517571 4 154314931 [A/C] NM_001253861,NR_045605,NM_032117 MND1,MND1,MND1 Silent,Silent,Silent rs10016021 4 154329842 [A/G] NM_001253861,NR_045605,NM_032117 MND1,MND1,MND1 Silent,Silent,Silent rs10030294 4 154339482 [T/C] rs17029966 4 154354566 [T/C] rs17029977 4 154355313 [T/C] rs17029990 4 154357175 [A/G] rs13113769 4 154363772 [A/G] rs13105829 4 154369706 [T/C] rs11941933 4 154371229 [T/C] rs11946908 4 154371262 [T/C] rs11728644 4 154373196 [A/G] rs6817170 4 154374984 [T/C] rs11732163 4 154376222 [A/G] rs1560940 4 154378572 [A/G] rs1836401 4 154389653 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs11936132 4 154391492 [T/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs2405712 4 154401015 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs713248 4 154408454 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs13119846 4 154415184 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs3816086 4 154418561 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs7685597 4 154420990 [T/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs10030193 4 154427319 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs13125518 4 154437863 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs7660240 4 154448872 [T/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs6535921 4 154450096 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs6850598 4 154452248 [T/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs17030097 4 154455240 [A/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs4466024 4 154460415 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs6810447 4 154461884 [T/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs6535924 4 154465994 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs3864176 4 154466939 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs11724474 4 154468420 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs11736782 4 154468648 [T/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs6535925 4 154469214 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs10011687 4 154474250 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs10034657 4 154474931 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs10001845 4 154478222 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L EXON Synonymous_V179V,Synonymous_V179V rs6848033 4 154479430 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L EXON Synonymous_R190R,Synonymous_R190R rs6848629 4 154479728 [T/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs10010874 4 154486552 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs10517573 4 154492573 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs7673291 4 154502068 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs10517574 4 154510843 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs9307909 4 154511677 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs7669418 4 154513627 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L EXON Missense_I605V,Missense_I604V rs7669741 4 154513722 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L EXON Synonymous_H636H,Synonymous_H635H rs17370297 4 154514965 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L EXON Missense_M646T,Missense_M645T rs17030216 4 154520071 [A/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs1063151 4 154525458 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L EXON Synonymous_A1098A,Synonymous_A1097A rs17030220 4 154527439 [T/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs6821970 4 154530639 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs13135353 4 154532047 [T/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs6535930 4 154540056 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs11099891 4 154541296 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs2241839 4 154543557 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs2289319 4 154544267 [A/G] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs6535932 4 154549663 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs2083288 4 154550603 [T/C] NM_001131007,NM_015196 TMEM131L,TMEM131L Silent,Silent rs7687239 4 154558964 [A/C] rs2033831 4 154559151 [A/G] rs6835748 4 154562769 [A/G] NR_134873 LOC100419170 Silent rs1025748 4 154563897 [T/G] NR_134873 LOC100419170 Silent rs2165084 4 154571036 [A/G] NR_134873 LOC100419170 Silent rs7656224 4 154571570 [A/G] NR_134873 LOC100419170 Silent rs10030403 4 154573663 [A/G] NR_134873 LOC100419170 Silent rs6853866 4 154581208 [T/C] NR_134873 LOC100419170 Silent rs1595625 4 154584591 [A/G] NR_134873 LOC100419170 Silent rs11727442 4 154585922 [A/G] NR_134873 LOC100419170 Silent rs17370673 4 154589724 [T/C] NR_134873 LOC100419170 Silent rs6835636 4 154590349 [A/G] NR_134873 LOC100419170 Silent rs13150331 4 154599622 [A/G] NR_134873 LOC100419170 Silent rs2099683 4 154604733 [A/C] rs893629 4 154604968 [A/G] rs7696323 4 154605745 [T/C] NM_001318787,NM_001318795,NM_003264,NM_001318793,NM_001318791,NM_001318790,NM_001318789,NM_001318796 TLR2,TLR2,TLR2,TLR2,TLR2,TLR2,TLR2,TLR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4696480 4 154607126 [T/A] NM_001318787,NM_001318795,NM_003264,NM_001318793,NM_001318791,NM_001318790,NM_001318789,NM_001318796 TLR2,TLR2,TLR2,TLR2,TLR2,TLR2,TLR2,TLR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1816702 4 154609523 [T/C] NM_001318787,NM_001318795,NM_003264,NM_001318793,NM_001318791,NM_001318790,NM_001318789,NM_001318796 TLR2,TLR2,TLR2,TLR2,TLR2,TLR2,TLR2,TLR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11938228 4 154621946 [A/C] NM_001318787,NM_001318795,NM_003264,NM_001318793,NM_001318791,NM_001318790,NM_001318789,NM_001318796 TLR2,TLR2,TLR2,TLR2,TLR2,TLR2,TLR2,TLR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3804099 4 154624656 [T/C] NM_001318787,NM_001318795,NM_003264,NM_001318793,NM_001318791,NM_001318790,NM_001318789,NM_001318796 TLR2,TLR2,TLR2,TLR2,TLR2,TLR2,TLR2,TLR2 EXON Synonymous_N199N,Synonymous_N199N,Synonymous_N199N,Synonymous_N199N,Synonymous_N199N,Synonymous_N199N,Synonymous_N199N,Synonymous_N199N rs3804100 4 154625409 [T/C] NM_001318787,NM_001318795,NM_003264,NM_001318793,NM_001318791,NM_001318790,NM_001318789,NM_001318796 TLR2,TLR2,TLR2,TLR2,TLR2,TLR2,TLR2,TLR2 EXON Synonymous_S450S,Synonymous_S450S,Synonymous_S450S,Synonymous_S450S,Synonymous_S450S,Synonymous_S450S,Synonymous_S450S,Synonymous_S450S rs7656411 4 154627655 [T/G] rs17030340 4 154632838 [A/G] NM_173662 RNF175 Silent rs7654018 4 154639667 [T/G] NM_173662 RNF175 Silent rs1439166 4 154641489 [T/C] NM_173662 RNF175 Silent rs1869947 4 154643503 [A/G] NM_173662 RNF175 Silent rs10517577 4 154644537 [T/C] NM_173662 RNF175 EXON Missense_M159V rs10440446 4 154645471 [A/G] NM_173662 RNF175 Silent rs4696487 4 154654076 [A/C] NM_173662 RNF175 Silent rs11099896 4 154664697 [T/G] NM_173662 RNF175 Silent rs1598632 4 154667382 [A/G] NM_173662 RNF175 Silent rs17030417 4 154670813 [A/G] NM_173662 RNF175 Silent rs17299041 4 154673127 [T/C] NM_173662 RNF175 Silent rs6838237 4 154675860 [T/C] NM_173662 RNF175 Silent rs1020702 4 154685712 [A/C] rs11099905 4 154686183 [T/C] rs2124647 4 154689930 [A/G] rs12639885 4 154700374 [A/G] rs6853435 4 154706016 [A/G] NM_003013 SFRP2 Silent rs3810765 4 154709480 [A/G] NM_003013 SFRP2 Silent rs4643790 4 154709854 [A/G] NM_003013 SFRP2 EXON Missense_A45V rs11937424 4 154711186 [A/G] rs732681 4 154725119 [A/C] rs1105491 4 154726634 [T/G] rs10026531 4 154727070 [A/G] rs11723258 4 154733070 [T/C] rs17030494 4 154743191 [T/G] rs10031057 4 154746806 [A/G] rs6843172 4 154760600 [T/C] rs994598 4 154768011 [T/C] rs959249 4 154768674 [A/G] rs1125228 4 154769052 [T/C] rs7673508 4 154769597 [T/C] rs954368 4 154771776 [T/C] rs9968342 4 154771820 [T/C] rs11099916 4 154772185 [A/G] rs1378933 4 154787090 [T/C] rs5009912 4 154791497 [A/C] rs17299673 4 154797919 [T/C] rs1378926 4 154799030 [T/G] rs7669875 4 154805474 [T/C] rs4696520 4 154806716 [A/G] rs17030719 4 154818522 [T/C] rs1993423 4 154824112 [T/C] rs17299833 4 154824331 [A/G] rs6831196 4 154827630 [A/C] rs4696521 4 154827974 [T/C] rs9995821 4 154828366 [T/C] rs9307914 4 154829156 [A/G] rs2045323 4 154831899 [A/G] rs10031184 4 154834707 [T/C] rs10011860 4 154835465 [A/C] rs11933412 4 154838816 [A/G] rs11724021 4 154850532 [A/C] rs11099924 4 154850835 [A/G] rs4235233 4 154855886 [A/G] rs6835798 4 154863536 [T/C] rs6835664 4 154863623 [A/G] rs13135284 4 154864750 [T/C] rs10024897 4 154867538 [T/C] rs4128249 4 154873677 [A/G] rs6841495 4 154877071 [A/G] rs6818192 4 154883493 [A/G] rs7661078 4 154883600 [A/G] rs4696523 4 154884393 [T/G] rs10026016 4 154885560 [A/G] rs1878449 4 154887604 [A/G] rs12505957 4 154888777 [A/G] rs4640650 4 154890126 [T/C] rs9790432 4 154890983 [A/G] rs1878452 4 154891251 [A/G] rs9790702 4 154891356 [T/C] rs11947700 4 154891741 [T/C] rs12508706 4 154896241 [T/C] rs12508232 4 154908045 [A/G] rs7663313 4 154908572 [A/G] rs12505740 4 154909285 [T/G] rs6813540 4 154930494 [T/G] rs13105395 4 154931179 [A/C] rs17030932 4 154932704 [T/C] rs6824634 4 154935574 [T/C] rs17030936 4 154936064 [T/C] rs2897074 4 154937685 [T/G] rs12641646 4 154938328 [T/G] rs7663305 4 154938646 [A/G] rs12512005 4 154950464 [T/G] rs17031027 4 154951725 [A/G] rs17031035 4 154951914 [A/G] rs6858024 4 154955187 [T/C] rs6858076 4 154955311 [A/G] rs4696526 4 154960908 [A/G] rs11931651 4 154965782 [A/G] rs17372382 4 154968120 [A/G] rs10517583 4 154968875 [A/C] rs6835823 4 154972357 [T/G] rs11099935 4 154974131 [T/C] rs11099936 4 154974203 [T/G] rs9999890 4 154975869 [T/C] rs2404921 4 154988567 [A/G] rs2404917 4 154995223 [A/G] rs2404916 4 154995463 [A/G] rs6827515 4 154997713 [A/G] rs9307919 4 155000585 [T/C] rs10005886 4 155007625 [T/G] rs17031131 4 155008496 [T/G] rs7667589 4 155009671 [A/C] rs17031138 4 155013194 [T/C] rs4266272 4 155018810 [T/C] rs1878448 4 155027927 [A/G] rs17031151 4 155042470 [A/G] rs4484280 4 155047033 [T/C] rs2014131 4 155047531 [T/C] rs938716 4 155049484 [T/C] rs17372674 4 155055498 [T/C] rs1574232 4 155057837 [A/C] rs10028852 4 155062069 [A/G] rs2404903 4 155071496 [A/G] rs4349583 4 155071789 [A/C] rs4432731 4 155080330 [T/C] rs6813896 4 155083506 [A/G] rs17031193 4 155084367 [T/C] rs17031199 4 155085018 [T/G] rs4696202 4 155099604 [A/C] rs4235235 4 155103453 [T/C] rs10517587 4 155110959 [T/C] rs4393979 4 155123244 [A/G] rs4696203 4 155129517 [T/C] rs11099942 4 155132707 [T/C] rs4385038 4 155135688 [A/G] rs10029359 4 155150910 [T/C] rs10517589 4 155153299 [T/G] rs17031276 4 155154936 [A/C] rs7655799 4 155156207 [A/G] NM_001358235 DCHS2 EXON Synonymous_D3199D rs6821649 4 155166327 [T/C] NM_001358235 DCHS2 Silent rs3828478 4 155182784 [A/G] NM_001358235 DCHS2 Silent rs4312742 4 155193398 [A/G] NM_001358235 DCHS2 Silent rs12506449 4 155194975 [T/C] NM_001358235 DCHS2 Silent rs6823540 4 155197891 [T/G] NM_001358235 DCHS2 Silent rs4447842 4 155205880 [A/G] NM_001358235 DCHS2 Silent rs7691036 4 155206899 [A/G] NM_001358235 DCHS2 Silent rs12508287 4 155209141 [A/G] NM_001358235 DCHS2 Silent rs10003606 4 155216371 [A/G] NM_001358235 DCHS2 Silent rs17031387 4 155219361 [A/G] NM_001358235 DCHS2 EXON Synonymous_D2035D rs17031391 4 155219373 [A/G] NM_001358235 DCHS2 EXON Synonymous_V2031V rs4696546 4 155229324 [T/C] NM_001358235 DCHS2 Silent rs12644248 4 155235392 [A/G] NM_001358235 DCHS2 Silent rs11935573 4 155241572 [A/G] NM_001358235 DCHS2 EXON Missense_S1660L rs12500437 4 155244475 [T/G] NM_001358235,NM_001142552 DCHS2,DCHS2 EXON Silent,Missense_P1342H rs1388082 4 155248664 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs12651681 4 155249362 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs10517595 4 155251015 [T/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs2130710 4 155251785 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs4696548 4 155252934 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs2172033 4 155255725 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs1021381 4 155257709 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs10517592 4 155258749 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs11726534 4 155269311 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs4696207 4 155269388 [A/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs7681342 4 155270460 [T/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs17031489 4 155273743 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs7687041 4 155281772 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs951728 4 155285052 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs10017772 4 155287535 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 EXON Missense_H768R,Missense_H768R rs11099951 4 155294563 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs11721758 4 155295076 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs13111929 4 155296207 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs6536003 4 155297245 [T/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs6820245 4 155297445 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs13134088 4 155299483 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs4696556 4 155300448 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs1388068 4 155300694 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs1388070 4 155300938 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs10857274 4 155307426 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs7686473 4 155319043 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs11099953 4 155329567 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs4550900 4 155331774 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs6851087 4 155333714 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs902455 4 155339195 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs2896868 4 155343176 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs10030235 4 155351627 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs4696572 4 155354916 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs1490648 4 155357830 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs1907155 4 155361244 [T/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs13146084 4 155364122 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs13122913 4 155364486 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs4696576 4 155371246 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs11731813 4 155379883 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs4696584 4 155397517 [A/G] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs10517593 4 155400984 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs9284660 4 155403593 [A/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs2404478 4 155408038 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs1873369 4 155408478 [A/C] NM_001358235,NM_001142552 DCHS2,DCHS2 Silent,Silent rs7656522 4 155411065 [T/C] NM_001358235,NM_001142552 DCHS2,DCHS2 EXON Synonymous_L481L,Synonymous_L481L rs6536016 4 155411104 [A/C] NM_001358235,NM_001142552 DCHS2,DCHS2 EXON Synonymous_S468S,Synonymous_S468S rs17031722 4 155411858 [T/G] NM_001358235,NM_001142552 DCHS2,DCHS2 EXON Missense_A217E,Missense_A217E rs1873367 4 155413362 [T/C] rs13132637 4 155413510 [T/C] rs13112066 4 155414179 [A/G] rs17031739 4 155414923 [A/G] rs10014500 4 155420487 [A/G] rs4345160 4 155421710 [A/G] rs4323084 4 155424231 [T/C] rs10019863 4 155427505 [T/G] rs6536017 4 155430666 [A/G] rs4547780 4 155432944 [A/G] rs4235247 4 155438339 [A/G] rs11737226 4 155442246 [A/G] rs4482740 4 155446305 [A/G] rs10008078 4 155448553 [A/G] rs7689945 4 155449629 [T/C] rs13435101 4 155449832 [A/C] rs6819508 4 155451187 [A/G] rs11099958 4 155451527 [T/C] rs4622984 4 155452233 [T/C] rs7654425 4 155456608 [A/G] NM_001201564,NM_002669 PLRG1,PLRG1 EXON Silent,Silent rs12642770 4 155460459 [T/C] NM_001201564,NM_002669 PLRG1,PLRG1 Silent,Silent rs12642469 4 155474222 [A/G] rs4508864 4 155481289 [T/C] rs1800787 4 155484015 [T/C] rs2227401 4 155486381 [T/C] NM_001184741,NM_005141 FGB,FGB Silent,Silent rs2227434 4 155487143 [T/C] NM_001184741,NM_005141 FGB,FGB EXON Silent,Missense_P100S rs6056 4 155488821 [T/C] NM_001184741,NM_005141 FGB,FGB EXON Synonymous_S130S,Synonymous_S189S rs6054 4 155489608 [T/C] NM_001184741,NM_005141 FGB,FGB EXON Missense_P206L,Missense_P265L rs6058 4 155490344 [T/G] NM_001184741,NM_005141 FGB,FGB EXON Synonymous_V222V,Synonymous_V281V rs4681 4 155490832 [T/C] NM_001184741,NM_005141 FGB,FGB EXON Synonymous_Y316Y,Synonymous_Y375Y rs4220 4 155491759 [A/G] NM_001184741,NM_005141 FGB,FGB EXON Missense_R419K,Missense_R478K rs2227421 4 155492224 [A/C] NM_001184741,NM_005141 FGB,FGB EXON Silent,Silent rs1044291 4 155493352 [T/C] NM_001184741,NM_005141 FGB,FGB EXON Silent,Silent rs4463047 4 155495533 [T/C] rs28673871 4 155504038 [A/G] rs2070022 4 155504948 [A/G] NM_000508 FGA EXON Silent rs2070020 4 155506239 [A/C] NM_000508 FGA Silent rs2070018 4 155508627 [A/G] NM_000508,NM_021871 FGA,FGA Silent,Silent rs2070016 4 155510314 [A/G] NM_000508,NM_021871 FGA,FGA Silent,Silent rs2070025 4 155511824 [T/C] NM_000508,NM_021871 FGA,FGA EXON Missense_I6V,Missense_I6V rs2070011 4 155511897 [T/C] NM_000508,NM_021871 FGA,FGA EXON Silent,Silent rs13109457 4 155514879 [A/G] rs11930511 4 155517510 [T/C] rs7659024 4 155520930 [A/G] rs2066865 4 155525276 [A/G] rs1049636 4 155525970 [A/G] NM_000509,NM_021870 FGG,FGG EXON Silent,Silent rs2066877 4 155527145 [T/C] NM_000509,NM_021870 FGG,FGG Silent,Silent rs2066870 4 155531333 [A/G] NM_000509,NM_021870 FGG,FGG EXON Missense_Y140H,Missense_Y140H rs2066857 4 155533675 [T/C] NM_000509,NM_021870 FGG,FGG Silent,Silent rs1800792 4 155534408 [T/C] rs12644950 4 155537321 [A/G] rs12648395 4 155541289 [T/C] rs7654093 4 155545072 [A/T] rs13137121 4 155548453 [A/G] rs10050268 4 155549354 [T/C] rs9790537 4 155552487 [A/G] rs4386585 4 155559499 [A/G] rs1074801 4 155576284 [A/C] rs6828439 4 155580418 [T/C] rs10023186 4 155599455 [A/G] rs1505241 4 155604679 [A/G] rs17031902 4 155609285 [A/C] rs10517596 4 155627814 [T/C] rs1546370 4 155632606 [T/C] rs17374304 4 155643638 [T/C] rs17031957 4 155651896 [T/C] rs17031960 4 155652184 [A/G] rs727153 4 155654421 [T/C] rs7660756 4 155664083 [A/G] NM_001301645 LRAT Silent rs201824 4 155668710 [A/G] NM_001301645,NM_004744 LRAT,LRAT Silent,Silent rs201821 4 155669865 [T/C] NM_001301645,NM_004744 LRAT,LRAT Silent,Silent rs12507608 4 155671626 [T/G] NM_001301645,NM_004744 LRAT,LRAT EXON Silent,Silent rs17032000 4 155672958 [T/G] NM_001301645,NM_004744 LRAT,LRAT EXON Silent,Silent rs17032006 4 155676534 [T/C] rs156500 4 155677315 [T/G] rs156501 4 155678345 [T/C] rs156553 4 155681012 [T/G] rs7662464 4 155686380 [A/G] rs11940892 4 155701520 [T/C] rs9992147 4 155702071 [T/C] rs156550 4 155705144 [A/C] NM_144979,NM_001277171,NM_001277173 RBM46,RBM46,RBM46 Silent,Silent,Silent rs156502 4 155720274 [T/C] NM_144979,NM_001277171,NM_001277173 RBM46,RBM46,RBM46 EXON Synonymous_N320N,Synonymous_N320N,Synonymous_N320N rs12651031 4 155720349 [A/C] NM_144979,NM_001277171,NM_001277173 RBM46,RBM46,RBM46 EXON Synonymous_G345G,Synonymous_G345G,Synonymous_G345G rs7691720 4 155739051 [A/G] NM_144979,NM_001277171,NM_001277173 RBM46,RBM46,RBM46 Silent,Silent,Silent rs166682 4 155742578 [A/G] NM_144979,NM_001277171,NM_001277173 RBM46,RBM46,RBM46 Silent,Silent,Silent rs156569 4 155742865 [T/G] NM_144979,NM_001277171,NM_001277173 RBM46,RBM46,RBM46 Silent,Silent,Silent rs12054563 4 155761481 [A/G] rs17302908 4 155764635 [T/C] rs4449396 4 155766258 [T/C] rs12498643 4 155772689 [A/G] rs987196 4 155775417 [A/G] rs11936628 4 155777196 [A/G] rs6536031 4 155777542 [A/G] rs6536032 4 155777864 [A/G] rs1559689 4 155778844 [T/C] rs1392554 4 155780165 [T/C] rs1500387 4 155786387 [A/G] rs17032149 4 155790646 [A/C] rs17375199 4 155794220 [T/G] rs17032154 4 155794261 [T/C] rs6813070 4 155794591 [T/G] rs1500383 4 155796464 [A/C] rs17032180 4 155803664 [A/G] rs1343937 4 155811101 [T/C] rs2404198 4 155811145 [T/C] rs17032207 4 155820246 [A/C] rs13101382 4 155821855 [A/C] rs10033629 4 155826061 [A/G] rs10002121 4 155830634 [A/G] rs2896784 4 155833011 [A/G] rs6536038 4 155835510 [T/C] rs4691385 4 155849300 [A/G] rs12498703 4 155854976 [A/G] rs1598639 4 155857196 [T/C] rs4691329 4 155861540 [A/C] rs17032275 4 155861812 [A/C] rs2124656 4 155867729 [A/G] rs17032316 4 155886241 [T/C] rs4691555 4 155891502 [T/C] rs1456457 4 155900720 [A/G] rs1378965 4 155903741 [A/G] rs11729306 4 155914904 [T/C] rs6845282 4 155922530 [T/C] rs10517612 4 155926051 [T/C] rs1456459 4 155927800 [A/G] rs6829756 4 155932934 [T/C] rs11099970 4 155933753 [T/C] rs10009064 4 155938012 [T/C] rs9998561 4 155947269 [A/G] rs7436102 4 155947430 [A/G] rs7656217 4 155951509 [A/G] rs10020550 4 155957348 [A/G] rs1378964 4 155960819 [A/G] rs10085000 4 155967231 [T/C] rs10013268 4 155967748 [A/G] rs876450 4 155968185 [T/G] rs17032387 4 155968437 [T/C] rs10016351 4 155968727 [A/G] rs1869965 4 155969377 [T/G] rs17032390 4 155969710 [T/C] rs1869966 4 155979144 [A/G] rs7668866 4 155985107 [T/C] rs6832923 4 155989391 [T/C] rs11735554 4 155995373 [A/G] rs11727277 4 155995695 [A/G] rs4690860 4 156002908 [A/G] rs17032433 4 156007879 [T/C] rs10008264 4 156008037 [A/G] rs6813291 4 156016684 [A/G] rs6831797 4 156024958 [A/G] rs1378957 4 156029149 [T/C] rs12650515 4 156038542 [A/C] rs6848512 4 156045227 [T/C] rs10213005 4 156050719 [A/C] rs17304378 4 156051299 [T/C] rs17032501 4 156055565 [A/G] rs10027655 4 156055961 [T/G] rs4323056 4 156057352 [A/G] rs17032524 4 156062435 [T/C] rs4499658 4 156066035 [T/C] rs2880418 4 156069879 [A/G] rs13138293 4 156074074 [T/G] rs1316749 4 156081090 [A/G] rs9790645 4 156081675 [A/G] rs17376560 4 156083037 [T/C] rs10030872 4 156087185 [T/C] rs1317400 4 156091935 [T/C] rs2880414 4 156093651 [A/C] rs6854846 4 156103755 [A/G] rs13111894 4 156111912 [T/C] rs10517606 4 156112853 [T/G] rs17304749 4 156113867 [T/C] rs13152353 4 156115288 [A/G] rs11941004 4 156122449 [T/C] rs13120088 4 156123035 [A/G] rs6849115 4 156124223 [T/C] rs12649641 4 156125333 [A/C] rs10212938 4 156128332 [T/C] rs17376826 4 156130948 [T/C] NM_000910 NPY2R Silent rs1574175 4 156133712 [T/C] NM_000910 NPY2R Silent rs1047214 4 156135676 [T/C] NM_000910 NPY2R EXON Synonymous_I195I rs17304901 4 156138372 [A/G] rs6846703 4 156139467 [A/G] rs6832844 4 156143159 [A/G] rs2342654 4 156149811 [A/G] rs2342649 4 156154314 [A/G] rs9991730 4 156159411 [T/C] rs1838484 4 156162049 [T/C] rs1822806 4 156163904 [T/C] rs17032722 4 156173215 [A/G] rs11099996 4 156174594 [T/C] rs17032732 4 156185574 [A/G] rs17032744 4 156189220 [A/G] rs991097 4 156189953 [T/C] rs35125259 4 156200509 [A/G] rs17032749 4 156214234 [T/G] rs1078275 4 156216726 [T/G] rs17377092 4 156217344 [T/G] rs17032793 4 156227224 [T/C] rs11726054 4 156237313 [T/C] rs1822804 4 156238370 [A/G] rs17032814 4 156239090 [A/G] rs750068 4 156245641 [A/G] rs10008006 4 156251105 [A/G] rs12650407 4 156261667 [A/G] rs10034144 4 156264133 [T/C] NM_001039580 MAP9 EXON Silent rs6817266 4 156265409 [A/G] NM_001039580 MAP9 EXON Silent rs2305050 4 156273768 [T/C] NM_001039580 MAP9 EXON Missense_N601D rs17032890 4 156281311 [T/G] NM_001039580,NR_125937 MAP9,LOC102724776 Silent,Silent rs17032893 4 156281371 [T/C] NM_001039580,NR_125937 MAP9,LOC102724776 EXON Synonymous_L333L,Silent rs6842102 4 156285170 [A/C] NM_001039580 MAP9 Silent rs3733390 4 156289900 [T/C] NM_001039580 MAP9 EXON Synonymous_L182L rs3733391 4 156289917 [A/G] NM_001039580 MAP9 EXON Missense_R177W rs6851250 4 156294921 [T/C] NM_001039580 MAP9 Silent rs17377679 4 156297060 [A/G] NM_001039580 MAP9 EXON Silent rs3775255 4 156300040 [T/C] rs908590 4 156311396 [T/C] rs7663620 4 156311510 [A/G] rs17032951 4 156313601 [A/G] rs6847136 4 156321133 [A/G] rs11100000 4 156322989 [T/C] rs1460128 4 156325539 [T/C] rs4691626 4 156340491 [T/G] rs9991561 4 156346580 [A/G] rs9995098 4 156347889 [A/G] rs10022584 4 156352066 [A/G] rs4690966 4 156353245 [A/G] rs4691631 4 156355515 [T/C] rs9996409 4 156370726 [A/G] rs4691643 4 156378568 [T/C] rs10011085 4 156380439 [A/G] rs12643194 4 156383288 [A/G] rs17377936 4 156387831 [T/C] rs1517293 4 156393197 [A/G] rs7442312 4 156399607 [A/C] rs17033050 4 156401693 [A/G] rs10013797 4 156410972 [A/G] rs1155097 4 156414715 [A/G] rs717695 4 156415404 [A/C] rs11938879 4 156416305 [T/G] rs6837085 4 156417909 [T/C] rs7440928 4 156434164 [A/C] rs1517294 4 156438083 [T/C] rs13124618 4 156442666 [T/C] rs1400623 4 156443877 [A/C] rs17033109 4 156446231 [A/G] rs17312460 4 156449830 [T/C] rs7436887 4 156450200 [A/C] rs2138741 4 156455542 [T/G] rs7671138 4 156460954 [A/G] rs10016993 4 156470555 [A/G] rs6850722 4 156472766 [T/C] rs7659237 4 156482330 [T/C] rs2879909 4 156484198 [A/G] rs6854265 4 156492983 [A/G] rs1032051 4 156499985 [A/G] rs1483041 4 156503440 [A/G] rs1483037 4 156511302 [T/C] rs11932514 4 156515275 [T/G] rs2625247 4 156515995 [A/G] rs1466516 4 156517289 [T/C] rs2625248 4 156518902 [T/G] rs2625249 4 156519123 [A/G] rs9998255 4 156519199 [A/G] rs13110106 4 156523316 [T/G] rs6813207 4 156524118 [A/G] rs4691787 4 156524415 [A/C] rs4691022 4 156526246 [T/G] rs7679296 4 156539639 [T/C] rs7680331 4 156540258 [A/G] rs2062177 4 156547554 [A/G] rs727773 4 156550942 [T/C] rs7692799 4 156555556 [T/C] rs7693386 4 156555835 [T/C] rs12642995 4 156557255 [T/C] rs2705434 4 156558695 [A/C] rs4691036 4 156561632 [A/G] rs2128650 4 156563407 [T/C] rs2705462 4 156569802 [T/G] rs6841458 4 156575786 [A/G] rs2705441 4 156580768 [T/G] rs11722434 4 156584397 [T/C] rs3806776 4 156586804 [T/C] rs3806777 4 156586949 [T/C] rs4691841 4 156597290 [A/C] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4691047 4 156598008 [T/C] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4691048 4 156598020 [T/C] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4691842 4 156598081 [A/G] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7685675 4 156598385 [A/G] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2625276 4 156600197 [T/C] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7658967 4 156607143 [A/G] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10008284 4 156610840 [A/G] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2101180 4 156614954 [A/G] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2306557 4 156617994 [A/G] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13143871 4 156619204 [T/C] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4691056 4 156619547 [T/G] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11945064 4 156627416 [A/G] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7689264 4 156630713 [T/C] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10019835 4 156633186 [T/C] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17033385 4 156633270 [T/C] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3796588 4 156635885 [T/C] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11100008 4 156637266 [T/C] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11100009 4 156637613 [T/C] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2306556 4 156638573 [A/G] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3796585 4 156639174 [A/G] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6854751 4 156641244 [A/G] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3816763 4 156643068 [A/G] NM_001130687,NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9993460 4 156644655 [T/C] NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent rs3796579 4 156648354 [A/G] NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent rs10019374 4 156649183 [A/G] NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 Silent,Silent,Silent,Silent,Silent,Silent rs7435347 4 156654735 [A/G] NM_001130682,NM_000856,NM_001256449,NM_001130683,NM_001130685,NM_001130684 GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1,GUCY1A1 EXON Silent,Silent,Silent,Silent,Silent,Silent rs11722059 4 156663407 [A/C] rs6814688 4 156666845 [A/G] rs4691073 4 156671888 [A/G] rs6838513 4 156672159 [T/C] rs6838946 4 156675369 [A/G] rs10517621 4 156677592 [T/C] rs17033462 4 156679329 [A/G] rs2219538 4 156683281 [A/G] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 Silent,Silent,Silent,Silent,Silent,Silent rs17033484 4 156686737 [T/C] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 Silent,Silent,Silent,Silent,Silent,Silent rs10012242 4 156687170 [A/G] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 Silent,Silent,Silent,Silent,Silent,Silent rs3796564 4 156688928 [T/C] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 Silent,Silent,Silent,Silent,Silent,Silent rs1563806 4 156692818 [T/G] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 Silent,Silent,Silent,Silent,Silent,Silent rs3796570 4 156699636 [A/C] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 Silent,Silent,Silent,Silent,Silent,Silent rs3775087 4 156703084 [A/G] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 Silent,Silent,Silent,Silent,Silent,Silent rs2340915 4 156704081 [T/C] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 Silent,Silent,Silent,Silent,Silent,Silent rs7661128 4 156713031 [A/G] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 Silent,Silent,Silent,Silent,Silent,Silent rs2305981 4 156721198 [T/C] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 EXON Synonymous_L363L,Synonymous_L315L,Synonymous_L315L,Synonymous_L383L,Synonymous_L405L,Synonymous_L383L rs3796574 4 156721410 [A/G] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 Silent,Silent,Silent,Silent,Silent,Silent rs4560354 4 156722774 [A/G] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 Silent,Silent,Silent,Silent,Silent,Silent rs17379405 4 156723081 [T/C] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 Silent,Silent,Silent,Silent,Silent,Silent rs17033572 4 156727377 [A/C] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 Silent,Silent,Silent,Silent,Silent,Silent rs922133 4 156728444 [T/G] NM_001291952,NM_001291955,NM_001291953,NM_001291954,NM_001291951,NM_000857 GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1,GUCY1B1 EXON Silent,Silent,Silent,Silent,Silent,Silent rs10011335 4 156729506 [T/C] rs5024165 4 156731162 [A/C] rs922134 4 156731952 [A/G] rs17313835 4 156739530 [T/C] rs10032771 4 156741858 [T/C] rs12499875 4 156745450 [T/C] rs6536096 4 156745915 [T/C] rs9992550 4 156758741 [T/C] NM_017419 ASIC5 Silent rs13148223 4 156762493 [A/G] NM_017419 ASIC5 Silent rs1563804 4 156772468 [T/C] NM_017419 ASIC5 Silent rs6817090 4 156780170 [T/C] NM_017419 ASIC5 Silent rs17033623 4 156784671 [A/G] NM_017419 ASIC5 EXON Synonymous_T92T rs6848883 4 156787340 [A/G] NM_017419 ASIC5 EXON Synonymous_N13N rs17033637 4 156787854 [T/C] rs17314234 4 156810755 [T/C] rs3775085 4 156823379 [A/C] rs10517626 4 156831444 [T/G] NM_005651 TDO2 Silent rs12502494 4 156832841 [T/C] NM_005651 TDO2 Silent rs10020753 4 156834028 [T/C] NM_005651 TDO2 Silent rs13128945 4 156839084 [T/C] NM_005651 TDO2 Silent rs6856558 4 156839953 [T/C] NM_005651 TDO2 Silent rs12509679 4 156844396 [T/C] rs9044 4 156846087 [A/G] NM_001334 CTSO EXON Silent rs1543108 4 156847230 [A/G] NM_001334 CTSO Silent rs12510557 4 156855433 [A/G] NM_001334 CTSO Silent rs1355875 4 156859190 [T/C] NM_001334 CTSO Silent rs7684248 4 156860391 [T/C] NM_001334 CTSO Silent rs11100024 4 156862104 [T/C] NM_001334 CTSO Silent rs13128318 4 156863252 [T/C] NM_001334 CTSO Silent rs10019161 4 156865486 [A/C] NM_001334 CTSO Silent rs7693476 4 156865988 [A/G] NM_001334 CTSO Silent rs13108152 4 156871631 [A/C] NM_001334 CTSO Silent rs10002427 4 156872831 [T/C] NM_001334 CTSO Silent rs10019975 4 156874028 [T/C] NM_001334 CTSO Silent rs13108041 4 156885169 [T/C] rs4691182 4 156886528 [A/G] rs10001803 4 156902056 [A/G] rs7666049 4 156902142 [A/C] rs17033879 4 156902320 [A/G] rs1355874 4 156906461 [T/C] rs13106367 4 156906856 [A/G] rs10029718 4 156916490 [A/G] rs4358343 4 156918475 [T/G] rs11939710 4 156930971 [T/C] rs11939830 4 156931181 [T/G] rs11100027 4 156937210 [T/C] rs7683170 4 156947188 [A/C] rs11941518 4 156950378 [A/G] rs4691233 4 156954890 [A/G] rs4691238 4 156963692 [A/G] rs6841250 4 156964349 [A/G] rs4691240 4 156967385 [A/G] rs6826026 4 156974697 [A/G] rs4605601 4 156986004 [A/G] rs6845616 4 156988133 [A/C] rs13149635 4 156991316 [T/C] rs11722256 4 156994724 [T/G] rs4690843 4 156998599 [A/G] rs4428239 4 157004706 [A/C] rs4417922 4 157006346 [T/C] rs11100040 4 157006954 [T/C] rs13117709 4 157008429 [A/G] rs10030044 4 157011923 [T/G] rs6836081 4 157012721 [T/C] rs4555581 4 157014586 [T/C] rs4437204 4 157021404 [A/G] rs13143174 4 157022492 [T/G] rs4558821 4 157030680 [A/C] rs4690853 4 157034642 [T/G] rs13140407 4 157041922 [A/G] rs4259017 4 157050382 [A/C] rs12506447 4 157059556 [A/C] rs4565033 4 157062345 [A/C] rs7661151 4 157065076 [T/C] rs6419277 4 157067528 [T/C] rs10016298 4 157068585 [T/C] rs10004557 4 157068808 [A/C] rs12331916 4 157074296 [A/G] rs11100049 4 157077635 [A/G] rs17314974 4 157086546 [T/C] rs17380673 4 157089145 [T/C] rs5027023 4 157089605 [A/C] rs10517630 4 157089919 [A/G] rs12499949 4 157090452 [T/G] rs10029540 4 157091971 [A/G] rs11721807 4 157094509 [T/G] rs4129759 4 157096990 [T/C] rs7676050 4 157098758 [A/G] rs17380799 4 157100233 [A/G] rs17034170 4 157100986 [A/C] rs12511271 4 157104688 [A/G] rs12186255 4 157109135 [T/C] rs4296721 4 157109267 [T/C] rs17034196 4 157116213 [A/G] rs4691308 4 157118100 [T/C] rs10014673 4 157119346 [A/G] rs6536157 4 157120820 [T/C] rs13103675 4 157124728 [A/G] rs4691310 4 157126324 [T/C] rs11726343 4 157128226 [A/G] rs2340252 4 157129218 [T/G] rs10029573 4 157129639 [A/G] rs17315339 4 157130289 [T/C] rs13102097 4 157131028 [A/G] rs17034238 4 157144339 [T/C] rs4600965 4 157144661 [A/G] rs10517634 4 157145352 [T/C] rs4691312 4 157146395 [A/C] rs13112531 4 157150175 [A/G] rs6833995 4 157152021 [T/C] rs2879724 4 157158799 [T/C] rs6536158 4 157160921 [T/C] rs10006636 4 157162514 [A/G] rs6830845 4 157163691 [T/C] rs11728161 4 157166746 [T/C] rs7700147 4 157167891 [T/C] rs10517633 4 157168163 [A/G] rs10003226 4 157168349 [A/G] rs13434949 4 157169331 [A/G] rs4440278 4 157171078 [A/G] rs2340254 4 157171201 [T/C] rs11734958 4 157174024 [A/G] rs10517632 4 157176193 [A/C] rs2340277 4 157181209 [A/G] rs13131866 4 157182630 [T/C] rs17034315 4 157185914 [T/G] rs7668315 4 157190788 [A/G] rs6818678 4 157197295 [A/C] rs4690859 4 157197353 [T/C] rs2220585 4 157213766 [A/G] rs6825273 4 157221159 [A/G] rs10517639 4 157232731 [A/G] rs10030326 4 157235050 [A/G] rs1352703 4 157244229 [T/G] rs13103662 4 157249803 [T/C] rs1873358 4 157252132 [A/G] rs2046876 4 157264625 [A/C] rs10021338 4 157267440 [A/G] rs17034476 4 157274381 [A/G] rs1532154 4 157279663 [T/C] rs7692934 4 157295245 [A/G] rs2340289 4 157295801 [A/G] rs10004475 4 157304598 [T/C] rs6840645 4 157305789 [A/C] rs6536171 4 157306101 [A/G] rs13147212 4 157306166 [T/C] rs1352705 4 157306780 [A/G] rs17034504 4 157309545 [A/G] rs13109236 4 157313519 [A/G] rs17034515 4 157317266 [A/G] rs7440464 4 157319069 [A/G] rs13149529 4 157324100 [T/C] rs7670864 4 157328376 [A/G] rs6813766 4 157332033 [T/C] rs13124827 4 157340210 [T/C] rs10517637 4 157342073 [A/G] rs6818354 4 157345022 [A/G] rs7667504 4 157345834 [T/C] rs17034575 4 157349944 [A/G] rs10517636 4 157351242 [T/C] rs6536176 4 157352057 [A/G] rs7669612 4 157354625 [T/C] rs13141045 4 157363345 [T/C] rs7669823 4 157363709 [A/G] rs6834515 4 157365096 [T/G] rs11938052 4 157371613 [A/G] rs9997210 4 157372570 [A/C] rs1352701 4 157380782 [T/C] rs1490571 4 157381223 [T/C] rs4691343 4 157381961 [A/C] rs6833736 4 157383426 [T/C] rs1586690 4 157383920 [A/G] rs10021375 4 157385298 [T/C] rs937068 4 157398759 [A/G] rs13150416 4 157403221 [T/C] rs6824856 4 157403920 [A/C] rs13435328 4 157405224 [T/C] rs17034741 4 157405580 [A/G] rs1123714 4 157409735 [T/C] rs7671552 4 157416571 [A/G] rs4305569 4 157419871 [A/C] rs13106670 4 157420901 [A/C] rs4328961 4 157433363 [A/G] rs6850881 4 157433970 [T/C] rs7694359 4 157437970 [T/C] rs11100060 4 157444701 [T/C] rs1402787 4 157449015 [A/C] rs1402788 4 157449136 [A/C] rs10517643 4 157450822 [A/G] rs952244 4 157458306 [T/C] rs17034885 4 157458846 [A/G] rs6832535 4 157459397 [T/C] rs1521710 4 157466506 [A/G] rs1521713 4 157469352 [A/C] rs2139977 4 157474312 [A/G] rs6536193 4 157484641 [A/C] rs1608012 4 157492586 [A/G] rs1915779 4 157493658 [A/C] rs28648624 4 157512342 [T/C] rs4569797 4 157517071 [T/G] rs10517648 4 157518336 [A/G] rs939687 4 157528405 [A/G] rs10028138 4 157530667 [T/C] rs1521717 4 157533294 [T/C] rs6811244 4 157535527 [T/C] rs1521724 4 157545843 [T/C] rs8180255 4 157548520 [A/G] rs2342141 4 157548539 [A/C] rs6817409 4 157551268 [T/C] rs17034990 4 157551842 [T/C] rs11935591 4 157554086 [T/C] rs12499279 4 157554917 [A/G] rs12507707 4 157555252 [A/G] rs4690871 4 157557522 [A/G] rs11943855 4 157557726 [A/G] rs12498803 4 157560957 [A/C] rs10005090 4 157563569 [T/C] rs17035016 4 157563908 [T/C] rs9998752 4 157568858 [A/G] rs7698424 4 157577439 [T/C] rs17317061 4 157583132 [T/G] rs1521716 4 157586380 [A/C] rs4691370 4 157589751 [A/G] rs4691372 4 157593703 [T/C] rs7684999 4 157594988 [A/G] rs10030015 4 157601193 [A/G] rs7689414 4 157608245 [T/C] rs1996770 4 157615583 [T/C] rs6847708 4 157622193 [T/C] rs9307949 4 157626640 [T/C] rs7665232 4 157629331 [T/G] rs9307950 4 157633839 [A/G] rs1469245 4 157642163 [A/G] rs2194868 4 157643986 [A/G] rs28403897 4 157655811 [T/C] rs10012388 4 157662111 [T/C] rs6855363 4 157670537 [T/C] rs1425486 4 157683685 [T/C] NR_036641,NM_016205 PDGFC,PDGFC EXON Silent,Silent rs4691377 4 157694651 [T/C] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs983473 4 157695392 [T/C] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs6816712 4 157703801 [T/C] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs6834932 4 157711526 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs17035257 4 157715062 [T/C] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs10023148 4 157722648 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs10019565 4 157728165 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs10517653 4 157733990 [T/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs10033375 4 157734312 [T/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs10008978 4 157765129 [T/C] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs2974254 4 157771062 [T/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs17035317 4 157772663 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs7682857 4 157776293 [T/C] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs2911941 4 157783398 [A/C] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs6811964 4 157785454 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs10517657 4 157786028 [A/C] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs17035367 4 157786225 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs342317 4 157789987 [T/C] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs1469243 4 157795071 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs342308 4 157797342 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs6812101 4 157815887 [A/C] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs17035418 4 157816206 [T/C] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs17231377 4 157818132 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs11728198 4 157825397 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs4691383 4 157836610 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs17231573 4 157837205 [A/C] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs10517660 4 157842396 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs10010472 4 157843781 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs6811767 4 157845568 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs17035447 4 157849689 [A/C] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs6845322 4 157884105 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs6811213 4 157886145 [A/G] NR_036641,NM_016205 PDGFC,PDGFC Silent,Silent rs3733486 4 157892434 [A/G] NR_036641,NM_016205 PDGFC,PDGFC EXON Silent,Silent rs1443237 4 157897554 [A/G] rs6833575 4 157906976 [A/G] rs1020286 4 157913736 [T/C] rs1015540 4 157914261 [T/C] rs11723576 4 157916511 [A/G] rs1443230 4 157921480 [A/G] rs4449462 4 157924933 [A/G] rs716680 4 157931688 [A/G] rs11100086 4 157936643 [T/C] rs765986 4 157940550 [T/C] rs4691389 4 157959931 [A/G] rs7664666 4 157959959 [T/G] rs4691391 4 157964285 [A/G] rs11100087 4 157965879 [A/G] rs2343744 4 157966554 [A/G] rs2343753 4 157980872 [T/C] rs6812324 4 157991592 [T/C] rs2880691 4 157993607 [T/G] rs4690875 4 157994894 [T/C] rs6852066 4 158002896 [T/C] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB Silent,Silent,Silent rs17035648 4 158018180 [A/G] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB Silent,Silent,Silent rs11100094 4 158035818 [A/G] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB Silent,Silent,Silent rs11100096 4 158036110 [A/G] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB Silent,Silent,Silent rs7654841 4 158051335 [T/C] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB Silent,Silent,Silent rs7655209 4 158051385 [A/G] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB Silent,Silent,Silent rs3775721 4 158064484 [T/G] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB Silent,Silent,Silent rs12507409 4 158065038 [T/C] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB EXON Synonymous_T277T,Synonymous_T277T,Synonymous_T277T rs17035790 4 158071999 [T/G] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB Silent,Silent,Silent rs1801154 4 158073913 [T/C] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB EXON Silent,Synonymous_L316L,Synonymous_L316L rs17035810 4 158074503 [T/C] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB Silent,Silent,Silent rs11945868 4 158074816 [T/C] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB Silent,Silent,Silent rs11947182 4 158084939 [T/C] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB Silent,Silent,Silent rs17035816 4 158088464 [A/G] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB Silent,Silent,Silent rs10517662 4 158093061 [T/C] NM_001166061,NM_000824,NM_001166060 GLRB,GLRB,GLRB EXON Silent,Silent,Silent rs17035827 4 158093737 [A/G] rs10517663 4 158105424 [T/G] rs6831272 4 158115848 [T/C] rs10025251 4 158131579 [T/C] rs6536221 4 158143886 [A/G] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs17035889 4 158155690 [T/C] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs17035903 4 158166689 [A/G] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs10461267 4 158168547 [A/G] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs9993365 4 158186342 [A/G] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs7682101 4 158199532 [T/C] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs10517666 4 158202542 [A/G] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs6844775 4 158205538 [T/C] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs17035947 4 158216329 [T/C] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs9999493 4 158218072 [A/G] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs10008950 4 158221234 [T/C] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs6536229 4 158222905 [T/G] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs4475186 4 158242540 [A/G] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs17244653 4 158252243 [T/C] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs34460606 4 158253979 [T/C] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 EXON Synonymous_S297S,Synonymous_S297S,Synonymous_S250S rs4426835 4 158264622 [T/C] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs6536234 4 158276014 [A/C] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs10012124 4 158279954 [A/G] NM_000826,NM_001083619,NM_001083620 GRIA2,GRIA2,GRIA2 Silent,Silent,Silent rs4550983 4 158292824 [T/G] rs4472185 4 158307259 [T/G] rs4691398 4 158322542 [A/G] rs11725238 4 158324379 [T/G] rs6823909 4 158327705 [T/C] rs11729662 4 158327990 [T/C] rs4234911 4 158333646 [T/C] rs4691400 4 158336110 [T/C] rs9992749 4 158346878 [T/G] rs12502016 4 158349609 [T/C] rs10517668 4 158357403 [T/C] rs1865353 4 158359767 [A/G] rs10029781 4 158361729 [A/C] rs6536237 4 158363688 [T/C] rs1369028 4 158366623 [A/G] rs10213312 4 158367001 [T/C] rs6842542 4 158375017 [A/G] rs11731394 4 158375048 [T/C] rs17186879 4 158382194 [A/G] rs17036167 4 158383798 [A/G] rs17246641 4 158383828 [A/G] rs12647438 4 158391794 [T/C] rs12054621 4 158396811 [A/G] rs10010100 4 158397845 [T/G] rs17036216 4 158416500 [A/G] rs6820047 4 158419053 [T/C] rs4691413 4 158419205 [T/G] rs1156225 4 158426633 [A/G] rs12507865 4 158430547 [T/C] rs725037 4 158443622 [T/C] rs1550017 4 158444071 [A/G] rs12054636 4 158444947 [A/G] rs6536246 4 158447249 [T/C] rs4475188 4 158452144 [A/C] rs1025554 4 158455363 [A/G] rs1594869 4 158462362 [T/C] rs6827325 4 158467400 [A/G] rs4234914 4 158468178 [T/C] rs17036351 4 158475705 [A/G] rs12331558 4 158479475 [T/C] rs1434384 4 158479507 [A/G] rs1036342 4 158492974 [A/G] rs6830776 4 158502750 [T/C] rs10857301 4 158503661 [T/C] rs10857302 4 158503818 [T/C] rs1387990 4 158518836 [A/G] rs728492 4 158524662 [T/C] rs1982845 4 158530437 [A/G] rs2344819 4 158533054 [T/C] rs11724621 4 158538338 [A/G] rs1907089 4 158540416 [T/C] rs7697239 4 158541687 [A/G] rs1490530 4 158541777 [A/G] rs6856493 4 158542093 [A/G] rs17036575 4 158549773 [T/C] rs17036576 4 158550241 [T/G] rs17036587 4 158551617 [A/C] rs1352695 4 158562269 [T/C] rs1352696 4 158562472 [T/C] rs6821900 4 158574310 [A/C] rs6835594 4 158576241 [A/C] rs10017629 4 158577288 [A/C] rs9995432 4 158577315 [A/G] rs10005357 4 158580884 [T/C] rs1490541 4 158584331 [A/G] rs10001392 4 158584939 [T/G] rs6839727 4 158586638 [T/C] rs1352693 4 158591563 [T/C] rs10517673 4 158593927 [T/G] rs2220582 4 158600677 [T/C] rs10024159 4 158602153 [T/G] rs17036640 4 158605184 [A/G] rs9998812 4 158608616 [T/G] rs4484348 4 158609602 [A/G] rs11100128 4 158620303 [A/G] rs4691434 4 158622875 [A/G] rs10030915 4 158634769 [A/G] rs1904949 4 158663069 [T/C] rs1383707 4 158669702 [A/G] rs11100132 4 158672216 [T/C] rs1481226 4 158685071 [T/C] rs12640357 4 158689561 [A/C] rs756334 4 158689938 [T/C] rs12648731 4 158697324 [T/C] rs1383704 4 158704610 [T/C] rs985731 4 158706314 [A/C] rs7671734 4 158711676 [T/C] rs7667778 4 158715149 [T/C] rs1531713 4 158715453 [A/G] rs727755 4 158724848 [T/C] rs13150049 4 158730857 [T/C] rs7434819 4 158731019 [A/G] rs6812217 4 158737934 [A/C] rs7677854 4 158742582 [T/C] rs7654999 4 158760439 [A/G] rs6536284 4 158765677 [A/G] rs6536285 4 158771076 [A/G] rs7693369 4 158778839 [A/G] rs9991982 4 158782030 [T/C] rs6836401 4 158786983 [A/G] rs7698656 4 158790324 [A/G] rs1481223 4 158793663 [A/G] rs1481231 4 158813228 [T/C] rs6857469 4 158813324 [A/G] rs1448451 4 158815510 [T/C] rs12331925 4 158834836 [T/C] rs11939514 4 158840495 [T/G] rs1375138 4 158842148 [T/C] rs17210208 4 158849702 [A/G] rs1448450 4 158857135 [A/G] rs2725476 4 158863930 [A/G] rs721604 4 158866939 [T/G] rs10002472 4 158867973 [A/G] rs10212653 4 158898321 [T/C] rs4447905 4 158898891 [A/G] rs10517684 4 158909445 [T/C] rs10857308 4 158917997 [A/C] rs10461245 4 158924505 [T/C] rs6847800 4 158932876 [T/G] rs4569796 4 158983480 [T/C] rs13144391 4 158988325 [A/G] rs13116234 4 158991908 [A/G] rs4388135 4 159014453 [T/G] rs10517685 4 159033327 [T/C] rs1320370 4 159043610 [T/C] rs11933750 4 159045764 [A/G] NM_001031700,NM_001128424,NM_016613 FAM198B,FAM198B,FAM198B EXON Silent,Silent,Silent rs7384 4 159045843 [A/G] NM_001031700,NM_001128424,NM_016613 FAM198B,FAM198B,FAM198B EXON Silent,Silent,Silent rs8370 4 159045966 [A/G] NM_001031700,NM_001128424,NM_016613 FAM198B,FAM198B,FAM198B EXON Silent,Silent,Silent rs17037047 4 159047172 [A/C] NM_001031700,NM_001128424,NM_016613 FAM198B,FAM198B,FAM198B EXON Silent,Silent,Silent rs4691455 4 159048217 [A/G] NM_001031700,NM_001128424,NM_016613 FAM198B,FAM198B,FAM198B EXON Silent,Silent,Silent rs4501266 4 159049771 [T/C] NM_001031700,NM_001128424,NM_016613 FAM198B,FAM198B,FAM198B Silent,Silent,Silent rs7692254 4 159055292 [A/G] NM_001031700,NM_001128424,NM_016613 FAM198B,FAM198B,FAM198B Silent,Silent,Silent rs4691458 4 159055765 [T/C] NM_001031700,NM_001128424,NM_016613 FAM198B,FAM198B,FAM198B Silent,Silent,Silent rs6833295 4 159064672 [T/G] NM_001031700,NM_001128424,NM_016613 FAM198B,FAM198B,FAM198B Silent,Silent,Silent rs2346784 4 159065799 [T/C] NM_001031700,NM_001128424,NM_016613 FAM198B,FAM198B,FAM198B Silent,Silent,Silent rs6830702 4 159076826 [T/C] NM_001031700,NM_001128424,NM_016613 FAM198B,FAM198B,FAM198B EXON Synonymous_S362S,Synonymous_S354S,Synonymous_S354S rs4690893 4 159083696 [T/C] NM_001031700,NM_001128424,NM_016613 FAM198B,FAM198B,FAM198B Silent,Silent,Silent rs17037201 4 159086166 [A/C] NM_001031700,NM_001128424,NM_016613 FAM198B,FAM198B,FAM198B Silent,Silent,Silent rs6849902 4 159089861 [T/C] NM_001031700,NM_001128424,NM_016613 FAM198B,FAM198B,FAM198B Silent,Silent,Silent rs2881373 4 159092633 [A/G] NM_001031700,NM_001128424,NM_016613,NR_147409,NR_147410,NR_147408,NR_147407 FAM198B,FAM198B,FAM198B,FAM198B-AS1,FAM198B-AS1,FAM198B-AS1,FAM198B-AS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13126694 4 159098784 [A/G] NR_147409,NR_147410,NR_147408,NR_147407 FAM198B-AS1,FAM198B-AS1,FAM198B-AS1,FAM198B-AS1 Silent,Silent,Silent,Silent rs10517688 4 159101703 [T/C] NR_147409,NR_147410,NR_147408,NR_147407 FAM198B-AS1,FAM198B-AS1,FAM198B-AS1,FAM198B-AS1 Silent,Silent,Silent,Silent rs10017534 4 159117861 [T/C] NR_147409,NR_147410,NR_147408,NR_147407 FAM198B-AS1,FAM198B-AS1,FAM198B-AS1,FAM198B-AS1 Silent,Silent,Silent,Silent rs7662398 4 159127462 [T/G] rs13126054 4 159128631 [T/G] rs11100154 4 159129407 [T/C] rs10019333 4 159132582 [T/C] NM_018342 TMEM144 Silent rs2225238 4 159138826 [T/G] NM_018342 TMEM144 Silent rs2272050 4 159158275 [A/G] NM_018342 TMEM144 Silent rs12504074 4 159158677 [A/G] NM_018342 TMEM144 EXON Synonymous_V188V rs12510198 4 159160422 [T/G] NM_018342 TMEM144 Silent rs3805144 4 159164640 [A/G] NM_018342 TMEM144 Silent rs1879656 4 159173102 [A/G] NM_018342 TMEM144 Silent rs1047725 4 159176109 [A/C] NM_018342 TMEM144 EXON Silent rs1410789 4 159179862 [T/G] rs1879658 4 159185633 [T/C] rs10857310 4 159185770 [A/G] rs1328925 4 159190290 [T/C] rs17037324 4 159194559 [A/G] rs11932623 4 159206103 [T/C] rs1574386 4 159224413 [T/C] rs1887891 4 159224455 [T/C] rs4691475 4 159227601 [T/C] rs11100160 4 159235840 [T/G] rs4577629 4 159241440 [A/G] rs4364309 4 159255213 [T/C] rs4379102 4 159255270 [A/G] rs6536306 4 159266567 [T/C] rs7435789 4 159275588 [T/C] rs12508350 4 159280560 [A/G] rs7441062 4 159295359 [A/G] rs6536309 4 159314091 [A/G] rs10857312 4 159317442 [A/G] rs2219191 4 159319980 [T/C] rs4691493 4 159331657 [A/G] rs6847255 4 159367847 [A/G] rs10517691 4 159399146 [A/G] rs7375480 4 159412248 [T/C] rs10024711 4 159417679 [A/G] rs7377646 4 159430701 [A/G] rs13117144 4 159433657 [T/G] rs13143911 4 159433681 [T/C] rs10517692 4 159434669 [A/C] rs6536350 4 159440817 [A/G] rs1455454 4 159441020 [A/G] rs7678831 4 159441539 [T/G] rs1455456 4 159442046 [A/G] rs7679484 4 159442057 [T/C] rs13139892 4 159445028 [T/C] NM_001253732,NM_021634,NR_045581,NM_001363776,NR_045579,NR_045584,NM_001253730,NM_001253728,NM_001253727,NM_001253733,NR_045580,NR_045582,NM_001253729,NR_045583 RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6845779 4 159460722 [A/G] NM_001253732,NM_021634,NR_045581,NM_001363776,NR_045579,NR_045584,NM_001253730,NM_001253728,NM_001253727,NM_001253733,NR_045580,NR_045582,NM_001253729,NR_045583 RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1902212 4 159464732 [A/G] NM_001253732,NM_021634,NR_045581,NM_001363776,NR_045579,NR_045584,NM_001253730,NM_001253728,NM_001253727,NM_001253733,NR_045580,NR_045582,NM_001253729,NR_045583 RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6536353 4 159474632 [T/C] NM_001253732,NM_021634,NR_045581,NM_001363776,NR_045579,NR_045584,NM_001253730,NM_001253728,NM_001253727,NM_001253733,NR_045580,NR_045582,NM_001253729,NR_045583 RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6832186 4 159481490 [T/C] NM_001253732,NM_021634,NR_045581,NM_001363776,NR_045579,NR_045584,NM_001253730,NM_001253728,NM_001253727,NM_001253733,NR_045580,NR_045582,NM_001253729,NR_045583 RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6857344 4 159490434 [A/G] NM_001253732,NM_021634,NR_045581,NM_001363776,NR_045579,NR_045584,NM_001253730,NM_001253728,NM_001253727,NM_001253733,NR_045580,NR_045582,NM_001253729,NR_045583 RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11940491 4 159500966 [T/C] NM_001253732,NM_021634,NR_045581,NM_001363776,NR_045579,NR_045584,NM_001253730,NM_001253728,NM_001253727,NM_001253733,NR_045580,NR_045582,NM_001253729,NR_045583 RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16999138 4 159503774 [A/G] NM_001253732,NM_021634,NR_045581,NM_001363776,NR_045579,NR_045584,NM_001253730,NM_001253728,NM_001253727,NM_001253733,NR_045580,NR_045582,NM_001253729,NR_045583 RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9990960 4 159551809 [A/G] NM_001253732,NM_021634,NR_045581,NM_001363776,NR_045579,NR_045584,NM_001253730,NM_001253728,NM_001253727,NM_001253733,NR_045580,NR_045582,NM_001253729,NR_045583 RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1,RXFP1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3210749 4 159588731 [A/C] NR_077235,NR_077234,NM_001008393 C4orf46,C4orf46,C4orf46 EXON Silent,Silent,Silent rs11544037 4 159588976 [A/C] NR_077235,NR_077234,NM_001008393 C4orf46,C4orf46,C4orf46 EXON Silent,Silent,Silent rs28396605 4 159592282 [A/G] NR_077235,NR_077234,NM_001008393 C4orf46,C4orf46,C4orf46 Silent,Silent,Silent rs4596202 4 159592948 [T/G] NR_077235,NR_077234,NM_001008393 C4orf46,C4orf46,C4orf46 EXON Silent,Silent,Synonymous_A2A rs4254722 4 159616166 [T/C] NM_001281737,NM_004453,NM_001281738 ETFDH,ETFDH,ETFDH Silent,Silent,Silent rs4336179 4 159616208 [A/G] NM_001281737,NM_004453,NM_001281738 ETFDH,ETFDH,ETFDH Silent,Silent,Silent rs12640862 4 159619426 [T/C] NM_001281737,NM_004453,NM_001281738 ETFDH,ETFDH,ETFDH Silent,Silent,Silent rs7679753 4 159620035 [A/C] NM_001281737,NM_004453,NM_001281738 ETFDH,ETFDH,ETFDH Silent,Silent,Silent rs11737481 4 159621250 [T/C] NM_001281737,NM_004453,NM_001281738 ETFDH,ETFDH,ETFDH Silent,Silent,Silent rs11935419 4 159624092 [A/G] NM_001281737,NM_004453,NM_001281738 ETFDH,ETFDH,ETFDH Silent,Silent,Silent rs17843967 4 159629637 [A/G] NM_001281737,NM_004453,NM_001281738 ETFDH,ETFDH,ETFDH EXON Synonymous_V557V,Synonymous_V604V,Synonymous_V543V rs17843966 4 159629814 [A/C] NM_001281737,NM_004453,NM_001281738 ETFDH,ETFDH,ETFDH EXON Silent,Silent,Silent rs8396 4 159630817 [T/C] NM_005038 PPID EXON Silent rs7689418 4 159631991 [T/G] NM_005038 PPID EXON Missense_L302I rs12505475 4 159635244 [T/C] NM_005038 PPID Silent rs6536366 4 159635573 [A/G] NM_005038 PPID Silent rs17037653 4 159640428 [T/C] NM_005038 PPID EXON Synonymous_K79K rs4690912 4 159672059 [T/G] rs7666007 4 159677712 [A/G] rs11100196 4 159682676 [A/G] rs4234923 4 159688477 [A/C] rs10857319 4 159729794 [T/C] NM_001346043,NM_020840,NM_001323916 FNIP2,FNIP2,FNIP2 Silent,Silent,Silent rs11725623 4 159732671 [T/C] NM_001346043,NM_020840,NM_001323916 FNIP2,FNIP2,FNIP2 Silent,Silent,Silent rs17285772 4 159754360 [T/C] NM_001346043,NM_020840,NM_001323916 FNIP2,FNIP2,FNIP2 Silent,Silent,Silent rs12504683 4 159760983 [A/G] NM_001346043,NM_020840,NM_001323916 FNIP2,FNIP2,FNIP2 Silent,Silent,Silent rs6828666 4 159779241 [A/G] NM_001346043,NM_020840,NM_001323916 FNIP2,FNIP2,FNIP2 Silent,Silent,Silent rs11946928 4 159791519 [A/G] NM_001346043,NM_020840,NM_001323916 FNIP2,FNIP2,FNIP2 EXON Synonymous_A595A,Synonymous_A949A,Synonymous_A972A rs4600878 4 159804265 [A/C] NM_001346043,NM_020840,NM_001323916 FNIP2,FNIP2,FNIP2 Silent,Silent,Silent rs17286457 4 159814072 [T/C] NM_001346043,NM_020840,NM_001323916 FNIP2,FNIP2,FNIP2 Silent,Silent,Silent rs17037740 4 159814163 [A/G] NM_001346043,NM_020840,NM_001323916 FNIP2,FNIP2,FNIP2 Silent,Silent,Silent rs10589 4 159827313 [T/C] NM_001346043,NM_020840,NM_001323916,NM_152543 FNIP2,FNIP2,FNIP2,C4orf45 EXON Silent,Silent,Silent,Silent rs4690915 4 159834341 [T/C] NM_152543 C4orf45 Silent rs9998332 4 159835412 [T/C] NM_152543 C4orf45 Silent rs10517695 4 159836467 [T/C] NM_152543 C4orf45 EXON Missense_R134H rs10010963 4 159839313 [T/C] NM_152543 C4orf45 Silent rs7678131 4 159851842 [T/G] NM_152543 C4orf45 Silent rs4146954 4 159860293 [T/C] NM_152543 C4orf45 Silent rs11724252 4 159863158 [A/G] NM_152543 C4orf45 Silent rs7670689 4 159866785 [T/C] NM_152543 C4orf45 Silent rs1820510 4 159873196 [T/C] NM_152543 C4orf45 Silent rs6536380 4 159876379 [T/C] NM_152543 C4orf45 Silent rs10003821 4 159877388 [T/C] NM_152543 C4orf45 Silent rs9784569 4 159881479 [T/C] NM_152543 C4orf45 EXON Synonymous_Q105Q rs11722868 4 159881943 [A/G] NM_152543 C4orf45 Silent rs7698077 4 159882696 [T/C] NM_152543 C4orf45 Silent rs714462 4 159885770 [T/C] NM_152543 C4orf45 Silent rs1971087 4 159888222 [T/C] NM_152543 C4orf45 Silent rs13136816 4 159890417 [A/G] NM_152543 C4orf45 Silent rs619128 4 159894250 [T/C] NM_152543 C4orf45 EXON Missense_G93E rs17037864 4 159894391 [A/G] NM_152543 C4orf45 EXON Missense_A46V rs637630 4 159912248 [T/G] NM_152543 C4orf45 Silent rs109119 4 159912840 [A/G] NM_152543 C4orf45 Silent rs553154 4 159913945 [A/G] NM_152543 C4orf45 Silent rs12510910 4 159920048 [A/C] NM_152543 C4orf45 Silent rs999411 4 159927765 [T/C] NM_152543 C4orf45 Silent rs1549850 4 159931261 [T/C] NM_152543 C4orf45 Silent rs11931163 4 159934179 [T/G] NM_152543 C4orf45 Silent rs552893 4 159939364 [T/C] NM_152543 C4orf45 Silent rs519274 4 159940905 [T/C] NM_152543 C4orf45 Silent rs476607 4 159943696 [A/G] NM_152543 C4orf45 Silent rs3929142 4 159944851 [A/G] NM_152543 C4orf45 Silent rs7660477 4 159948180 [T/C] NM_152543 C4orf45 Silent rs6849580 4 159950990 [T/C] NM_152543 C4orf45 Silent rs1559887 4 159952353 [T/C] NM_152543 C4orf45 Silent rs601196 4 159954244 [A/G] NM_152543 C4orf45 Silent rs2053346 4 159958150 [T/C] rs6834079 4 159961231 [T/G] rs12331691 4 159963042 [T/G] rs588811 4 159976179 [T/G] rs581849 4 159981640 [T/C] rs2014078 4 160019492 [T/C] rs2306651 4 160026546 [A/G] NM_001351724 RAPGEF2 Silent rs10003940 4 160053187 [T/C] NM_001351724 RAPGEF2 Silent rs13148447 4 160079961 [A/C] NM_001351724 RAPGEF2 Silent rs7681750 4 160084403 [A/G] NM_001351724 RAPGEF2 Silent rs7656697 4 160088137 [T/C] NM_001351724 RAPGEF2 Silent rs4410485 4 160102354 [A/C] NM_001351724 RAPGEF2 Silent rs9997385 4 160118458 [A/G] NM_001351724 RAPGEF2 Silent rs10050099 4 160124407 [T/G] NM_001351724 RAPGEF2 Silent rs7685028 4 160132990 [A/G] NM_001351724 RAPGEF2 Silent rs12502799 4 160143615 [T/G] NM_001351724 RAPGEF2 Silent rs11730876 4 160147159 [T/C] NM_001351724 RAPGEF2 Silent rs13139002 4 160151176 [A/G] NM_001351724,NM_001351726,NM_001351725 RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent rs6536404 4 160173041 [A/G] NM_001351724,NM_001351726,NM_001351725 RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent rs4690933 4 160173942 [T/C] NM_001351724,NM_001351726,NM_001351725 RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent rs11100213 4 160184658 [T/G] NM_001351724,NM_001351726,NM_001351725 RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent rs13145422 4 160185669 [T/C] NM_001351724,NM_001351726,NM_001351725 RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent rs10428456 4 160186284 [T/C] NM_001351724,NM_001351726,NM_001351725 RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent rs10021301 4 160194364 [A/G] NM_001351724,NM_001351726,NM_001351725,NM_001351727,NM_001351728,NM_014247 RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent,Silent,Silent,Silent rs4396948 4 160208630 [A/G] NM_001351724,NM_001351726,NM_001351725,NM_001351727,NM_001351728,NM_014247 RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent,Silent,Silent,Silent rs6840293 4 160209816 [A/G] NM_001351724,NM_001351726,NM_001351725,NM_001351727,NM_001351728,NM_014247 RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent,Silent,Silent,Silent rs4295222 4 160210862 [A/G] NM_001351724,NM_001351726,NM_001351725,NM_001351727,NM_001351728,NM_014247 RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent,Silent,Silent,Silent rs1133055 4 160221964 [T/C] NM_001351724,NM_001351726,NM_001351725,NM_001351727,NM_001351728,NM_014247 RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent,Silent,Silent,Silent rs9799685 4 160223891 [T/G] NM_001351724,NM_001351726,NM_001351725,NM_001351727,NM_001351728,NM_014247 RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent,Silent,Silent,Silent rs7678811 4 160240899 [T/C] NM_001351724,NM_001351726,NM_001351725,NM_001351727,NM_001351728,NM_014247 RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent,Silent,Silent,Silent rs10022399 4 160249722 [A/G] NM_001351724,NM_001351726,NM_001351725,NM_001351727,NM_001351728,NM_014247 RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent,Silent,Silent,Silent rs13134868 4 160261053 [A/G] NM_001351724,NM_001351726,NM_001351725,NM_001351727,NM_001351728,NM_014247 RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent,Silent,Silent,Silent rs17038049 4 160264140 [T/C] NM_001351724,NM_001351726,NM_001351725,NM_001351727,NM_001351728,NM_014247 RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2 EXON Synonymous_N976N,Synonymous_N860N,Synonymous_N860N,Synonymous_N815N,Synonymous_N815N,Synonymous_N815N rs11723634 4 160267334 [T/C] NM_001351724,NM_001351726,NM_001351725,NM_001351727,NM_001351728,NM_014247 RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent,Silent,Silent,Silent rs3805139 4 160270184 [A/G] NM_001351724,NM_001351726,NM_001351725,NM_001351727,NM_001351728,NM_014247 RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent,Silent,Silent,Silent rs10025560 4 160278606 [A/G] NM_001351724,NM_001351726,NM_001351725,NM_001351727,NM_001351728,NM_014247 RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2 Silent,Silent,Silent,Silent,Silent,Silent rs3749464 4 160279732 [T/C] NM_001351724,NM_001351726,NM_001351725,NM_001351727,NM_001351728,NM_014247 RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2,RAPGEF2 EXON Silent,Silent,Silent,Silent,Silent,Silent rs1969578 4 160283091 [T/C] rs17038083 4 160284465 [A/G] rs2016061 4 160284623 [T/C] rs12505843 4 160299086 [A/G] rs10517701 4 160322345 [T/C] rs4440173 4 160327856 [A/G] rs1125409 4 160331540 [A/G] rs11730206 4 160338309 [T/G] rs2348164 4 160341351 [T/G] rs6812880 4 160344788 [T/C] rs2699023 4 160347129 [T/G] rs10018060 4 160348741 [A/C] rs2699027 4 160349432 [A/G] rs2699032 4 160350425 [A/G] rs2699036 4 160352798 [A/G] rs4690942 4 160355746 [A/G] rs4591547 4 160357877 [A/G] rs11100229 4 160361747 [T/C] rs4691567 4 160364016 [A/G] rs2707687 4 160369165 [A/G] rs11947461 4 160374255 [T/C] rs7675279 4 160377484 [T/C] rs2699006 4 160381253 [T/G] rs5008449 4 160382933 [A/G] rs6833365 4 160384694 [A/G] rs13111198 4 160388504 [A/G] rs17038294 4 160405305 [A/G] rs2851820 4 160406190 [T/C] rs13144517 4 160412034 [T/C] rs2851828 4 160412665 [A/G] rs1922645 4 160419271 [T/C] rs2251664 4 160420152 [A/G] rs2851836 4 160421579 [T/C] rs1922642 4 160423997 [A/G] rs7660063 4 160424615 [A/G] rs2851769 4 160425090 [T/C] rs4621382 4 160426520 [T/C] rs1317333 4 160426970 [T/C] rs11724165 4 160442645 [A/G] rs2851798 4 160446640 [A/G] rs6824835 4 160456060 [T/G] rs2851790 4 160460895 [A/C] rs1893953 4 160474408 [T/G] rs11100238 4 160477057 [A/G] rs10018944 4 160482843 [T/C] rs6823356 4 160483950 [T/C] rs11945017 4 160485488 [T/C] rs4691577 4 160486937 [A/G] rs1393576 4 160488212 [A/G] rs998888 4 160494830 [T/G] rs2348414 4 160497236 [T/C] rs6858329 4 160512123 [T/C] rs924678 4 160512801 [A/G] rs6848958 4 160514021 [T/C] rs9994725 4 160515218 [T/G] rs17239575 4 160516090 [A/G] rs2000886 4 160521480 [T/C] rs1502739 4 160523363 [A/C] rs13125739 4 160526077 [A/G] rs17318405 4 160526796 [T/C] rs7679927 4 160537156 [T/C] rs4383572 4 160558972 [T/C] rs11933100 4 160560872 [A/G] rs12331504 4 160563128 [A/G] rs1502752 4 160574450 [T/C] rs10517704 4 160578021 [A/G] rs9985638 4 160591060 [T/G] NR_146278 LINC02233 Silent rs1304931 4 160594616 [A/C] NR_146278 LINC02233 Silent rs6536452 4 160594757 [T/C] NR_146278 LINC02233 Silent rs10517706 4 160596412 [T/C] NR_146278 LINC02233 Silent rs1118040 4 160604277 [T/C] NR_146278 LINC02233 Silent rs4358345 4 160606236 [A/C] NR_146278 LINC02233 Silent rs1502736 4 160607399 [T/C] NR_146278 LINC02233 Silent rs1580882 4 160609723 [T/C] NR_146278 LINC02233 Silent rs11100250 4 160628006 [T/C] NR_146278 LINC02233 Silent rs9762089 4 160630642 [T/C] NR_146278 LINC02233 Silent rs2348616 4 160640315 [T/C] NR_146278 LINC02233 Silent rs2348620 4 160645543 [T/C] NR_146278 LINC02233 Silent rs17319860 4 160647109 [T/C] NR_146278 LINC02233 Silent rs1224511 4 160654172 [A/G] NR_146278 LINC02233 Silent rs6536467 4 160661776 [T/C] NR_146278 LINC02233 Silent rs13114723 4 160665557 [A/G] NR_146278 LINC02233 Silent rs10009182 4 160669731 [T/C] NR_146278 LINC02233 Silent rs6814758 4 160700862 [A/G] rs10032864 4 160705097 [A/G] rs10020212 4 160708061 [T/C] rs13118321 4 160708104 [T/C] rs7662429 4 160714143 [A/C] rs1457806 4 160715001 [T/C] rs17038866 4 160715660 [T/C] rs6831972 4 160715825 [A/G] rs17038867 4 160715913 [T/C] rs9307996 4 160719567 [A/G] rs35272456 4 160736225 [T/C] rs6811354 4 160742791 [A/G] rs13150069 4 160751151 [T/G] rs13115100 4 160753524 [A/C] rs4690958 4 160766276 [A/G] rs7672637 4 160815681 [T/C] rs11945058 4 160816351 [A/G] rs4690963 4 160817334 [A/G] rs4119125 4 160822830 [A/G] rs6849301 4 160823974 [A/G] rs13133802 4 160828500 [A/G] rs7659695 4 160834831 [T/C] rs4518196 4 160836194 [T/C] rs10025964 4 160840630 [T/C] rs7669476 4 160857395 [T/C] rs6536484 4 160863267 [A/G] rs4271965 4 160869705 [A/G] rs6814814 4 160884054 [A/G] rs2349006 4 160885494 [T/C] rs6536489 4 160889694 [T/G] rs17039057 4 160891342 [T/C] rs11100268 4 160904180 [T/C] rs13142965 4 160904953 [T/C] rs12650598 4 160905205 [A/G] rs4690967 4 160907341 [A/G] rs7442549 4 160908132 [T/C] rs1035895 4 160930806 [T/G] rs17324206 4 160937416 [A/C] rs10517712 4 160955059 [A/G] rs1428412 4 160965723 [A/G] rs2711273 4 160974552 [T/C] rs2708233 4 160979988 [T/C] rs7689243 4 160981899 [A/C] rs2708232 4 160983529 [T/C] rs1366345 4 160991913 [T/C] rs7674336 4 160992265 [A/G] rs17326052 4 160993666 [A/C] rs17326199 4 160999691 [A/G] rs10031516 4 161000801 [A/G] rs6839487 4 161001529 [T/G] rs7655275 4 161004631 [T/G] rs1593935 4 161010407 [T/C] rs1651215 4 161014288 [T/C] rs1651214 4 161019327 [A/G] rs1612279 4 161024158 [A/G] rs11935561 4 161025225 [T/C] rs17261688 4 161028817 [A/G] rs2464855 4 161041088 [T/C] rs17039226 4 161059762 [A/C] rs17328104 4 161061075 [A/G] rs1013340 4 161062144 [T/G] rs17262338 4 161063535 [T/C] rs11725207 4 161064449 [T/C] rs1922867 4 161066117 [T/C] rs11723182 4 161066459 [A/C] rs1882684 4 161067895 [A/G] rs1316398 4 161068421 [A/G] rs13127767 4 161068507 [A/G] rs10084990 4 161071059 [A/G] rs6852530 4 161083178 [T/C] rs17262799 4 161083206 [A/G] rs12331818 4 161086241 [T/C] rs11930198 4 161094977 [T/C] rs10017226 4 161095976 [A/G] rs9998533 4 161097392 [A/G] rs1922875 4 161102726 [A/G] rs10004177 4 161104701 [T/G] rs17329555 4 161105967 [T/C] rs1950167 4 161109431 [T/C] rs10022595 4 161110042 [A/G] rs12506633 4 161113226 [A/G] rs11731668 4 161114136 [A/G] rs1922869 4 161114166 [A/G] rs12648235 4 161115744 [T/C] rs1279186 4 161116677 [A/G] rs998213 4 161116857 [A/C] rs2349537 4 161117083 [A/G] rs960665 4 161129045 [T/C] rs17039338 4 161129696 [T/C] rs17039340 4 161130442 [T/C] rs1922876 4 161130933 [T/G] rs10461271 4 161131305 [T/C] rs17039360 4 161134770 [T/C] rs13138661 4 161135028 [A/G] rs13152810 4 161137084 [T/C] rs7686798 4 161141895 [A/C] rs10031180 4 161148252 [A/G] rs17039372 4 161149134 [T/C] rs17039374 4 161149981 [T/G] rs11725459 4 161156298 [A/G] rs17039386 4 161159633 [A/G] rs6835451 4 161160240 [T/C] rs1845715 4 161168319 [A/G] rs295240 4 161179694 [T/C] rs13145112 4 161206712 [A/G] rs295251 4 161211232 [A/G] rs1895182 4 161213118 [T/C] rs17271770 4 161213904 [A/C] rs953014 4 161214912 [A/G] rs953012 4 161215280 [T/G] rs4269136 4 161216205 [A/C] rs4490418 4 161218094 [A/G] rs10017605 4 161221634 [A/C] rs12374311 4 161224554 [A/G] rs7694810 4 161225387 [T/G] rs1874347 4 161225712 [A/G] rs12500560 4 161227697 [A/G] rs11939980 4 161229808 [T/C] rs2112267 4 161234438 [T/C] rs1495603 4 161239313 [T/G] rs2349960 4 161240066 [A/G] rs1532391 4 161240911 [A/G] rs13123632 4 161249029 [T/C] rs6846953 4 161255092 [A/G] rs6818044 4 161257623 [A/G] rs13115184 4 161267468 [A/G] rs12503435 4 161270471 [A/C] rs3910586 4 161274885 [A/G] rs294514 4 161280429 [A/G] rs17272220 4 161287144 [T/G] rs17272241 4 161287754 [A/C] rs2350244 4 161291816 [A/G] rs3846243 4 161292814 [A/G] rs294526 4 161294866 [T/C] rs9884424 4 161300559 [A/G] rs9884861 4 161300574 [A/G] rs9308003 4 161300792 [A/G] rs17332185 4 161300938 [A/G] rs17039504 4 161301370 [T/C] rs6835941 4 161306164 [A/G] rs1946867 4 161307463 [T/C] rs10014285 4 161307972 [A/G] rs6536518 4 161308423 [A/G] rs7675061 4 161310422 [A/G] rs7674486 4 161314077 [T/G] rs1583732 4 161320477 [T/G] rs17039540 4 161323274 [A/C] rs7678343 4 161336215 [A/G] rs13124867 4 161337411 [T/C] rs7376552 4 161343388 [T/C] rs4691655 4 161344370 [T/C] rs4691663 4 161348483 [T/C] rs10005281 4 161363563 [A/G] rs1157128 4 161365143 [T/G] rs1595663 4 161366230 [A/G] rs12640159 4 161366623 [A/G] rs1347903 4 161379828 [T/C] rs1371251 4 161381482 [A/G] rs1946869 4 161386383 [T/G] rs1439408 4 161395453 [A/G] rs6827968 4 161399652 [A/C] rs1898871 4 161402299 [A/G] rs1020131 4 161404700 [T/C] rs17039615 4 161406478 [A/G] rs13136944 4 161409160 [T/G] rs13151634 4 161411394 [T/C] rs12498920 4 161413994 [A/G] rs4525928 4 161421752 [A/C] rs10857329 4 161425366 [A/G] rs9995630 4 161427827 [T/C] rs4690982 4 161428827 [T/C] rs4690983 4 161429238 [T/C] rs1898872 4 161436797 [A/G] rs1595667 4 161441599 [T/C] rs7681545 4 161442245 [A/G] rs1561492 4 161443164 [A/C] rs17039652 4 161444504 [T/C] rs17039654 4 161447090 [A/G] rs11930824 4 161451545 [A/G] rs10032921 4 161453186 [A/C] rs4626153 4 161457938 [A/G] rs1439395 4 161464002 [T/C] rs11941490 4 161468822 [T/C] rs17355669 4 161472909 [A/G] rs10018218 4 161473319 [T/C] rs17039750 4 161477815 [T/G] rs17277682 4 161479466 [A/G] rs17039765 4 161480674 [A/C] rs17039767 4 161482246 [A/C] rs4691681 4 161482994 [A/G] rs13140082 4 161489245 [T/C] rs10031651 4 161495175 [A/G] rs12511322 4 161501719 [A/G] rs11938367 4 161508641 [A/G] rs10517721 4 161515815 [T/C] rs2350469 4 161517400 [A/G] rs7667168 4 161522527 [T/C] rs4443235 4 161524114 [T/G] rs6847636 4 161534644 [T/C] rs1992108 4 161548582 [T/C] rs11945623 4 161552712 [A/G] rs11100301 4 161567725 [T/G] rs6536530 4 161571071 [A/G] rs4691689 4 161575165 [A/G] rs4691690 4 161575183 [T/C] rs1436944 4 161575686 [T/C] rs17359034 4 161578427 [T/C] rs17039966 4 161578634 [A/C] rs17039968 4 161579050 [T/C] rs11100304 4 161590091 [T/C] rs1436942 4 161595023 [T/C] rs17039992 4 161595152 [A/G] rs4690990 4 161597298 [A/G] rs2164631 4 161598173 [A/G] rs1036471 4 161598367 [T/C] rs6843805 4 161617009 [T/C] rs2350477 4 161620939 [A/C] rs9308012 4 161623467 [T/G] rs1370171 4 161632032 [A/G] rs6536531 4 161636751 [T/C] rs4691696 4 161646978 [A/G] rs6843165 4 161656017 [A/G] rs6857015 4 161657993 [T/C] rs4081678 4 161659251 [A/G] rs3846247 4 161662308 [A/G] rs10011041 4 161666367 [A/G] rs13130301 4 161676056 [A/C] rs3895760 4 161679470 [A/G] rs10517723 4 161685302 [T/C] rs3842909 4 161685540 [A/G] rs6835611 4 161689479 [T/C] rs12499554 4 161698345 [A/G] rs6853708 4 161703150 [T/C] rs7654849 4 161703960 [A/C] rs3846259 4 161705136 [T/C] rs1420877 4 161707186 [T/C] rs10031243 4 161713693 [T/C] rs3909235 4 161718544 [T/C] rs17040213 4 161730366 [A/G] rs4488900 4 161733077 [A/G] rs4691702 4 161736289 [T/C] rs4691703 4 161736792 [T/G] rs3909239 4 161741448 [A/G] rs2349301 4 161742881 [T/G] rs13112276 4 161745970 [A/G] rs7667388 4 161756548 [T/C] rs17040246 4 161761676 [T/G] rs17040262 4 161763818 [A/G] rs1420884 4 161764629 [A/C] rs2349306 4 161766489 [T/G] rs1345460 4 161769559 [T/C] rs4594673 4 161771838 [A/G] rs1362705 4 161777781 [A/G] rs4295220 4 161778204 [T/C] rs6840597 4 161783422 [T/C] rs13130758 4 161785031 [T/C] rs9991811 4 161785599 [A/C] rs6854952 4 161785781 [A/G] rs1420899 4 161788263 [T/C] rs4273418 4 161790472 [A/G] rs7694824 4 161790594 [A/G] rs17534473 4 161792134 [T/C] rs988569 4 161795832 [A/G] rs17040351 4 161799400 [A/G] rs9997826 4 161808171 [T/C] rs4463025 4 161808304 [T/C] rs11737365 4 161809149 [T/C] rs4399939 4 161818208 [T/C] rs4613522 4 161828952 [T/G] rs4691713 4 161837715 [T/C] rs9992795 4 161840651 [A/G] rs4444780 4 161846866 [T/C] rs10050122 4 161848243 [A/G] rs9993721 4 161856084 [A/G] rs9993952 4 161856343 [A/G] rs7436001 4 161861640 [T/C] rs13122745 4 161863893 [A/G] rs6858095 4 161864128 [A/G] rs4529002 4 161875145 [T/C] rs11735987 4 161878326 [A/G] rs12503470 4 161889983 [T/C] rs13132985 4 161907084 [T/C] rs4345122 4 161912988 [A/G] rs11100327 4 161924832 [T/C] rs1982202 4 161935342 [A/G] rs4379019 4 161936611 [A/G] rs4467511 4 161940430 [A/G] rs9991854 4 161940921 [A/C] rs4234935 4 161946368 [A/G] rs6536560 4 161952228 [A/G] rs17301015 4 161953729 [T/C] rs2028307 4 161968079 [A/G] rs17040579 4 161982414 [A/G] rs2218107 4 161987342 [A/G] rs1523553 4 161987905 [T/C] rs10517733 4 161991740 [T/G] rs17040617 4 161996191 [A/C] rs1523558 4 162002577 [T/C] rs17375159 4 162002921 [T/C] rs4591550 4 162003624 [T/C] rs12644817 4 162009525 [A/G] rs12645681 4 162024164 [T/C] rs10011336 4 162027911 [T/C] rs10014253 4 162028591 [A/C] rs2313008 4 162029797 [A/G] rs17040676 4 162056332 [T/C] rs6813133 4 162059629 [A/G] rs13132807 4 162065899 [A/C] rs10517736 4 162076088 [A/G] rs10212879 4 162080425 [T/C] rs17040713 4 162082401 [A/C] rs17378274 4 162088272 [A/C] rs17040725 4 162100530 [A/C] rs6536577 4 162105557 [A/G] rs17040761 4 162112961 [T/C] rs12511816 4 162114535 [A/G] rs13148588 4 162115247 [A/G] rs13110266 4 162129844 [A/G] rs12510599 4 162143173 [A/G] rs719880 4 162147112 [A/G] rs992955 4 162153936 [T/C] rs6831434 4 162155361 [A/G] rs10517739 4 162158370 [T/C] rs17314203 4 162158922 [T/C] rs1444285 4 162163105 [A/C] rs10026817 4 162168945 [T/C] rs958247 4 162192797 [A/G] rs1348530 4 162193568 [A/G] rs7665845 4 162194539 [A/G] rs12502171 4 162195147 [T/C] rs10517742 4 162202272 [A/C] rs10029508 4 162205711 [T/C] rs9308024 4 162207646 [T/C] rs13102687 4 162207662 [T/C] rs7667597 4 162219569 [A/G] rs13106146 4 162221987 [T/C] rs13107435 4 162222374 [A/G] rs7679790 4 162227134 [A/G] rs4691748 4 162227234 [A/C] rs7687260 4 162228270 [A/G] rs11730185 4 162234554 [T/G] rs5010472 4 162235785 [A/G] rs5010468 4 162235993 [A/G] rs34018667 4 162236018 [A/G] rs1530425 4 162236867 [A/G] rs1017543 4 162241086 [A/G] rs2313748 4 162243468 [A/G] rs12331118 4 162248546 [A/G] rs2313565 4 162249966 [T/C] rs10003505 4 162250538 [A/G] rs4470583 4 162250932 [A/G] rs11100365 4 162252857 [A/G] rs4691749 4 162255173 [T/C] rs12500982 4 162255732 [T/C] rs12512282 4 162255770 [T/C] rs12503004 4 162257254 [T/C] rs4691007 4 162257301 [T/G] rs6857927 4 162260229 [A/C] rs4446272 4 162260938 [T/G] rs4327441 4 162261170 [A/G] rs7438721 4 162262333 [A/G] rs2314136 4 162262615 [T/C] rs2314137 4 162265796 [A/C] rs17040932 4 162268088 [A/G] rs10007083 4 162272259 [A/G] rs10010638 4 162273772 [A/C] rs6832320 4 162274024 [A/G] rs17336367 4 162276769 [T/C] rs16999316 4 162281464 [A/G] rs2314141 4 162281985 [T/C] rs12643813 4 162284626 [A/G] rs17336722 4 162285736 [A/G] rs13142107 4 162288572 [T/C] rs17040974 4 162301366 [T/C] rs2313567 4 162303020 [T/C] rs6823286 4 162303613 [T/C] rs17040982 4 162307000 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 EXON Missense_K814E,Missense_K805E,Missense_K815E rs17040984 4 162307060 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 EXON Synonymous_R794R,Synonymous_R785R,Synonymous_R795R rs12374210 4 162311913 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs11725954 4 162320903 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs2314105 4 162321420 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs6820464 4 162324395 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs12500921 4 162324909 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4547755 4 162327265 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs12639796 4 162328955 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17338054 4 162329244 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs2872530 4 162334309 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4518193 4 162350385 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs7694864 4 162355688 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs7669737 4 162361217 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4691761 4 162362473 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs11945487 4 162367270 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs7681811 4 162370089 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs12650551 4 162376761 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17339031 4 162378641 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs16999322 4 162379746 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17041092 4 162380016 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs6536595 4 162382240 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17041096 4 162383466 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4358350 4 162384818 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs11937911 4 162389854 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs6839543 4 162390574 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs6832611 4 162396765 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs6842030 4 162415916 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs11100371 4 162419531 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17339916 4 162424868 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs10000255 4 162425218 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17399436 4 162426149 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4518198 4 162426629 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17340154 4 162428196 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4434196 4 162439632 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4355345 4 162458688 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17041191 4 162458750 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs16999330 4 162460563 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs12512822 4 162461996 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs13141240 4 162473868 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4501178 4 162477082 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs9996901 4 162482595 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4330312 4 162489958 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs11100375 4 162501251 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs10003025 4 162505383 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4691773 4 162507230 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs6858225 4 162511370 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs10003547 4 162514902 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4355346 4 162516553 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs10517746 4 162521710 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs13149906 4 162522247 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs10857338 4 162525511 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs11100377 4 162530770 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17343587 4 162548816 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs13435758 4 162549221 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17403181 4 162552883 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17343847 4 162556751 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17638339 4 162577430 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs9308035 4 162595918 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4532194 4 162600018 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17638464 4 162602209 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs11100382 4 162612565 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs7442468 4 162633257 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs12500089 4 162637121 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs10013537 4 162644069 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1982121 4 162646894 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs6820280 4 162647126 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1434621 4 162649655 [G/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs13119737 4 162650185 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs10517750 4 162650988 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17596009 4 162651017 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1347353 4 162651104 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs986704 4 162657759 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs10517752 4 162663106 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1434614 4 162666856 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4691025 4 162669309 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs11100385 4 162678311 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs11942761 4 162687669 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs7690085 4 162709000 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs7668203 4 162710868 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1560926 4 162714672 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4579074 4 162715169 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs13130537 4 162718372 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17041550 4 162719690 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs2082669 4 162733762 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs2014158 4 162733928 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs12504254 4 162734547 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs359147 4 162734835 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs359144 4 162735000 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs359142 4 162737097 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1946656 4 162738654 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17596748 4 162741975 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs930441 4 162761890 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs9308039 4 162763646 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1440588 4 162764014 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs11938253 4 162770250 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs16999366 4 162782993 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs732224 4 162783324 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs6831077 4 162785412 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs11732750 4 162787495 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs11100393 4 162789741 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4691032 4 162801373 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1431490 4 162803540 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs2053430 4 162814045 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17536725 4 162816953 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1440604 4 162817423 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs7666181 4 162827306 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs10517755 4 162828061 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1348065 4 162837458 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1549828 4 162840766 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs359502 4 162841653 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 EXON Synonymous_D103D,Synonymous_D103D,Synonymous_D104D rs1440610 4 162844090 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17597465 4 162856156 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs2067907 4 162871521 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs994654 4 162876772 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs359512 4 162881087 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1440587 4 162885218 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs12643775 4 162886928 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs749833 4 162888136 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1842985 4 162891609 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs45426 4 162894103 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs466478 4 162900278 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs10028812 4 162904449 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1483549 4 162904939 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs359486 4 162907833 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17041860 4 162912081 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs10022486 4 162923324 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1483550 4 162925724 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17598127 4 162927440 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs11100407 4 162929158 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs922926 4 162930214 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs7658962 4 162934834 [T/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1905363 4 162944335 [T/G] NM_001128427,NM_001128428,NM_020116,NR_125888 FSTL5,FSTL5,FSTL5,LOC101928052 Silent,Silent,Silent,Silent rs1471693 4 162953565 [A/G] NM_001128427,NM_001128428,NM_020116,NR_125888 FSTL5,FSTL5,FSTL5,LOC101928052 Silent,Silent,Silent,Silent rs11942587 4 162967006 [A/G] NM_001128427,NM_001128428,NM_020116,NR_125888 FSTL5,FSTL5,FSTL5,LOC101928052 Silent,Silent,Silent,Silent rs1483557 4 162967558 [T/C] NM_001128427,NM_001128428,NM_020116,NR_125888 FSTL5,FSTL5,FSTL5,LOC101928052 Silent,Silent,Silent,Silent rs12649057 4 162973873 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs6855540 4 162983015 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1492457 4 162985367 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17459954 4 162985402 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs2101216 4 162991888 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs2086754 4 162992246 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs10030663 4 162995995 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs6814301 4 163005050 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs10012213 4 163006849 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs971300 4 163007304 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs973516 4 163008238 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs10005652 4 163011663 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs9991417 4 163012287 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1388834 4 163019507 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1492468 4 163030012 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17538472 4 163038241 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs11931941 4 163038864 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17599262 4 163039228 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs13134589 4 163041211 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs13110363 4 163043184 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs13138416 4 163043362 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17041987 4 163044149 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs6826488 4 163045747 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs6833160 4 163046421 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1032394 4 163048238 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs4441714 4 163048530 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs2872800 4 163055350 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17042032 4 163057553 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs13109373 4 163060499 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs17460693 4 163061051 [T/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs7375984 4 163062608 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1388840 4 163073169 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs6818975 4 163074444 [A/G] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs1492463 4 163079683 [A/C] NM_001128427,NM_001128428,NM_020116 FSTL5,FSTL5,FSTL5 Silent,Silent,Silent rs6828789 4 163091388 [A/C] rs11731180 4 163092108 [T/C] rs13112114 4 163092479 [T/C] rs12646105 4 163094997 [T/C] rs13135573 4 163099369 [A/G] rs13142621 4 163100289 [T/C] rs6839078 4 163110932 [A/C] rs7688606 4 163111888 [A/G] rs4574362 4 163135702 [T/C] rs13101933 4 163149785 [T/G] rs4292288 4 163152054 [A/C] rs4234947 4 163159563 [T/C] rs10213246 4 163161476 [T/C] rs13108616 4 163178092 [A/G] rs10009342 4 163179938 [T/C] rs9999880 4 163179997 [A/G] rs7672069 4 163186335 [A/G] rs4306919 4 163191154 [A/C] rs4429685 4 163195242 [A/C] rs10029007 4 163196418 [T/C] rs6536647 4 163200863 [A/G] rs11100424 4 163205479 [A/G] rs4691041 4 163211495 [A/G] rs4343679 4 163216127 [A/G] rs4355349 4 163221194 [A/G] rs13141291 4 163230830 [T/C] rs4398485 4 163237694 [T/C] rs6852854 4 163237790 [A/G] rs4413364 4 163237809 [A/G] rs4405972 4 163239474 [T/C] rs7660998 4 163239721 [A/G] rs4440177 4 163243053 [A/G] rs4533716 4 163243244 [A/G] rs7684439 4 163245174 [T/C] rs11941679 4 163248122 [T/C] rs7697133 4 163256188 [T/C] rs13138079 4 163263038 [A/G] rs6857753 4 163264951 [T/C] rs1993024 4 163265313 [A/G] rs12508239 4 163267782 [A/G] rs10517764 4 163269056 [T/C] rs7656506 4 163270445 [T/C] rs921343 4 163281348 [A/G] rs921344 4 163281547 [T/C] rs12646037 4 163281692 [T/C] rs1118864 4 163282170 [T/C] rs11100437 4 163283456 [A/G] rs7656923 4 163284691 [A/G] rs7658242 4 163285245 [T/C] rs11936687 4 163288053 [A/G] rs11731765 4 163302616 [A/G] rs1450384 4 163314790 [A/G] rs1597469 4 163318230 [T/C] rs13140705 4 163318348 [T/C] rs2597444 4 163324016 [A/G] rs6845152 4 163324468 [A/C] rs1901120 4 163326947 [A/G] rs17042481 4 163327373 [T/G] rs17600575 4 163329336 [T/C] rs11931857 4 163332375 [A/G] rs2060670 4 163332671 [T/C] rs2712675 4 163334309 [A/G] rs11100443 4 163337191 [T/C] rs12645341 4 163337355 [A/G] rs2712683 4 163339290 [A/G] rs13129429 4 163353217 [T/G] rs1597472 4 163356033 [A/G] rs10009808 4 163359226 [T/C] rs2712674 4 163366516 [A/G] rs2597484 4 163367829 [A/G] rs11100444 4 163370862 [A/G] rs17042519 4 163376177 [T/C] rs10029930 4 163376243 [T/C] rs7684098 4 163379149 [A/G] rs1450395 4 163385544 [T/C] rs1450394 4 163385682 [T/C] rs17462361 4 163390849 [A/G] rs4139 4 163390933 [T/C] rs10517768 4 163392037 [A/G] rs10021001 4 163403791 [T/C] rs4521302 4 163406113 [A/C] rs9991428 4 163408044 [T/G] rs10003033 4 163417093 [A/C] rs6839249 4 163419055 [A/G] rs17042571 4 163421425 [T/G] rs2045631 4 163432830 [T/C] rs1471260 4 163443708 [A/G] rs1380722 4 163444684 [A/G] rs7681690 4 163449149 [A/G] rs987567 4 163452300 [T/C] rs10428343 4 163475257 [T/G] rs6856230 4 163484868 [A/G] rs11100450 4 163487232 [T/C] rs1870602 4 163494122 [A/G] rs6536667 4 163494546 [A/G] rs13147036 4 163495571 [A/G] rs4691857 4 163497956 [A/G] rs195898 4 163523865 [A/G] rs2872973 4 163525235 [T/C] rs7688628 4 163525786 [A/G] rs195894 4 163527435 [T/G] rs195891 4 163532717 [T/C] rs6810504 4 163533054 [T/C] rs182016 4 163534998 [T/C] rs1903291 4 163540150 [A/G] rs17042707 4 163540897 [T/C] rs6849368 4 163543945 [A/C] rs195982 4 163564805 [T/C] rs10489050 4 163565725 [A/G] rs195913 4 163573991 [T/C] rs1471264 4 163575092 [T/G] rs195937 4 163580271 [T/C] rs195921 4 163605363 [T/C] rs195559 4 163650534 [A/G] rs195557 4 163658871 [T/G] rs17042829 4 163671744 [A/C] rs17042861 4 163690655 [A/G] rs4691059 4 163691920 [T/C] rs1458151 4 163696346 [T/C] rs2320181 4 163703018 [T/C] rs6839846 4 163707598 [A/G] rs10517773 4 163713049 [T/C] rs11941363 4 163716888 [A/C] rs13130233 4 163718686 [A/G] rs995302 4 163725002 [A/G] rs10857349 4 163731187 [A/G] rs17042954 4 163736954 [A/G] rs11729764 4 163739342 [A/G] rs7680184 4 163742756 [A/C] rs11723207 4 163749607 [T/C] rs4234951 4 163758401 [T/C] rs4144993 4 163758431 [T/C] rs745351 4 163758757 [T/C] rs10033012 4 163766726 [T/C] rs17470149 4 163770664 [T/C] rs17470184 4 163771109 [T/C] rs2054210 4 163781864 [A/C] rs1458140 4 163782459 [T/G] rs4691874 4 163793257 [T/C] rs2012358 4 163795102 [T/C] rs10007144 4 163795426 [A/C] rs4691060 4 163799376 [A/G] rs7694367 4 163802929 [A/G] rs11100465 4 163804334 [A/G] rs2315664 4 163808442 [T/C] rs6829472 4 163810202 [T/G] rs6849181 4 163814472 [A/G] rs4361343 4 163817354 [A/G] rs4691062 4 163819887 [A/G] rs12501673 4 163830516 [A/G] rs6817485 4 163834952 [T/C] rs7673703 4 163836677 [A/G] rs13119671 4 163838176 [T/C] rs6841751 4 163843547 [A/G] rs6842513 4 163843642 [A/G] rs11934494 4 163848930 [A/G] rs6852825 4 163854178 [T/C] rs6846212 4 163856550 [A/G] rs6847504 4 163856962 [A/G] rs11100469 4 163868041 [T/G] rs17043205 4 163872705 [A/G] rs11938430 4 163879822 [A/C] rs11100472 4 163882204 [A/G] rs10032913 4 163884609 [A/G] rs4263350 4 163896310 [A/G] rs9684182 4 163901211 [A/G] rs17470878 4 163906288 [T/C] rs11945512 4 163913035 [A/G] rs4546199 4 163913951 [T/C] rs6536694 4 163934608 [A/G] rs7662233 4 163938611 [T/G] rs6849055 4 163939622 [A/G] rs4130504 4 163955092 [A/G] rs4130505 4 163955254 [A/G] rs6536699 4 163956998 [A/C] rs4132177 4 163957656 [A/C] rs4301068 4 163966691 [T/C] rs4691888 4 163969466 [A/G] rs1531589 4 163973796 [A/G] rs6846180 4 163974516 [A/G] rs4691889 4 163980423 [T/C] rs2320331 4 163990008 [T/C] rs2086241 4 164000953 [A/G] rs7676823 4 164007992 [A/G] rs11100478 4 164010468 [T/C] rs11100479 4 164012901 [T/C] rs11941112 4 164013880 [T/C] rs17574812 4 164025528 [A/G] rs1055263 4 164045822 [A/G] rs1061075 4 164049916 [A/C] NM_001128931,NM_138386 NAF1,NAF1 EXON Silent,Silent rs7693533 4 164066710 [T/C] NM_001128931,NM_138386 NAF1,NAF1 Silent,Silent rs17609340 4 164081668 [A/C] NM_001128931,NM_138386 NAF1,NAF1 Silent,Silent rs6536704 4 164083616 [T/C] NM_001128931,NM_138386 NAF1,NAF1 Silent,Silent rs12331663 4 164087753 [A/G] NM_001128931,NM_138386 NAF1,NAF1 EXON Missense_P43S,Missense_P43S rs17609388 4 164092042 [A/G] rs10001148 4 164101614 [A/G] rs12643618 4 164113310 [T/C] rs12644622 4 164114844 [T/C] rs11732624 4 164118272 [T/G] rs10517778 4 164121326 [A/G] rs6536707 4 164123026 [A/G] rs2127214 4 164126538 [T/C] rs4293752 4 164134572 [T/C] rs4348051 4 164139950 [T/C] rs11732470 4 164158859 [T/C] rs11932242 4 164191370 [T/G] rs11945307 4 164196370 [T/C] rs4642195 4 164200171 [A/G] rs4128839 4 164203507 [A/G] rs3967761 4 164211883 [T/C] rs7688754 4 164221286 [T/C] rs4057791 4 164225132 [A/C] rs6828820 4 164230540 [T/C] rs1574637 4 164242092 [A/G] rs10004426 4 164243690 [T/C] rs9764 4 164245405 [T/C] NM_000909 NPY1R EXON Silent rs10033119 4 164245854 [A/G] NM_000909 NPY1R EXON Silent rs5578 4 164246489 [T/G] NM_000909 NPY1R EXON Missense_K374T rs4691075 4 164249485 [T/C] NM_000909 NPY1R Silent rs12510421 4 164250436 [A/C] NM_000909 NPY1R Silent rs7687423 4 164250797 [A/G] NM_000909 NPY1R Silent rs11100490 4 164252839 [T/C] NM_000909 NPY1R Silent rs6852829 4 164259120 [T/G] rs10022662 4 164259613 [A/C] rs4234955 4 164260276 [A/G] rs4314240 4 164264776 [A/G] rs11100494 4 164270253 [A/C] NM_006174,NM_001317092,NM_001317091 NPY5R,NPY5R,NPY5R Silent,Silent,Silent rs4443234 4 164276942 [A/G] rs7662762 4 164278765 [T/G] rs13151717 4 164282763 [T/C] rs6851444 4 164283085 [T/C] rs6831008 4 164283347 [A/C] rs12503838 4 164284929 [A/G] rs4234956 4 164287042 [T/C] rs4234957 4 164288341 [A/G] rs10031046 4 164288523 [T/G] rs7658224 4 164293345 [T/C] rs13121948 4 164294776 [T/C] rs10024430 4 164295108 [A/G] rs11938071 4 164310785 [A/G] rs10517780 4 164313181 [T/C] rs1441716 4 164325064 [T/C] rs4691082 4 164328368 [T/C] rs6536728 4 164333380 [T/C] rs11937784 4 164340073 [T/G] rs9992637 4 164350705 [T/C] rs1441720 4 164357974 [T/C] rs10014739 4 164362850 [A/C] rs6536732 4 164366036 [A/G] rs11931331 4 164370114 [A/G] rs993264 4 164377038 [T/G] rs2028488 4 164377063 [A/G] rs2320767 4 164378054 [A/G] rs1545226 4 164379003 [T/C] rs13121637 4 164380632 [T/C] rs12642830 4 164383199 [A/G] rs10005483 4 164384209 [A/G] rs10017973 4 164387952 [A/G] rs4234960 4 164389550 [T/C] rs9308060 4 164392225 [A/G] rs17043707 4 164394011 [T/C] NM_032136 TKTL2 EXON Synonymous_S292S rs10004056 4 164396241 [A/G] rs1441723 4 164398485 [T/G] rs2119677 4 164398884 [A/G] rs2320618 4 164407600 [T/C] rs2119678 4 164408033 [T/C] rs1073547 4 164409556 [A/C] rs10034495 4 164411073 [A/G] rs2276978 4 164415792 [A/G] NM_018352 TMA16 EXON Silent rs2276977 4 164415930 [T/C] NM_018352 TMA16 EXON Silent rs11730351 4 164417245 [A/G] NM_018352 TMA16 Silent rs7657886 4 164418356 [T/C] NM_018352 TMA16 Silent rs7658704 4 164418831 [T/C] NM_018352 TMA16 Silent rs12500221 4 164436103 [A/G] NM_018352 TMA16 Silent rs1044722 4 164447976 [A/C] NM_001166373,NM_017923 MARCH1,MARCH1 EXON Silent,Silent rs9993575 4 164454771 [T/C] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs2044052 4 164457232 [T/C] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs17473073 4 164460645 [T/C] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs17473108 4 164463778 [A/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs12508980 4 164465746 [A/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs13130399 4 164466824 [T/C] NM_001166373,NM_017923 MARCH1,MARCH1 EXON Synonymous_A165A,Synonymous_A148A rs11100507 4 164470301 [A/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs6815345 4 164471823 [A/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs2320771 4 164474468 [T/C] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs17473171 4 164474591 [A/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs11100508 4 164475425 [T/C] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs6843683 4 164476240 [A/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs11100509 4 164478874 [T/C] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs10029699 4 164479967 [T/C] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs17473283 4 164487447 [T/C] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs13115712 4 164489038 [A/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs1877314 4 164490018 [A/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs10001689 4 164492395 [T/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs7693363 4 164499999 [T/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs6821802 4 164500909 [A/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs11945604 4 164506561 [T/C] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs7695517 4 164509032 [T/C] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs7693970 4 164514168 [T/C] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs10213166 4 164521066 [T/C] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs7692553 4 164522666 [A/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs17657444 4 164527583 [A/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs1511779 4 164528452 [A/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs17473521 4 164529581 [A/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs950565 4 164529829 [T/G] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs907435 4 164532325 [T/C] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs3792614 4 164532973 [A/C] NM_001166373,NM_017923 MARCH1,MARCH1 Silent,Silent rs4413365 4 164536663 [A/G] NM_001166373 MARCH1 Silent rs10030322 4 164540801 [T/C] NM_001166373 MARCH1 Silent rs7686154 4 164542625 [T/G] NM_001166373 MARCH1 Silent rs2036905 4 164547230 [T/G] NM_001166373 MARCH1 Silent rs2175490 4 164547492 [T/C] NM_001166373 MARCH1 Silent rs11725683 4 164561013 [A/C] NM_001166373 MARCH1 Silent rs13149834 4 164562638 [T/C] NM_001166373 MARCH1 Silent rs16853 4 164564775 [A/G] NM_001166373 MARCH1 Silent rs13105536 4 164570672 [A/G] NM_001166373 MARCH1 Silent rs17044007 4 164571149 [T/G] NM_001166373 MARCH1 Silent rs17473710 4 164571285 [A/G] NM_001166373 MARCH1 Silent rs7655593 4 164572108 [T/C] NM_001166373 MARCH1 Silent rs1533151 4 164575991 [A/C] NM_001166373 MARCH1 Silent rs1511776 4 164582457 [A/G] NM_001166373 MARCH1 Silent rs6536747 4 164595552 [T/G] NM_001166373 MARCH1 Silent rs17473787 4 164595666 [T/G] NM_001166373 MARCH1 Silent rs6826691 4 164602209 [T/C] NM_001166373 MARCH1 Silent rs17044034 4 164606988 [T/C] NM_001166373 MARCH1 Silent rs998117 4 164611944 [T/G] NM_001166373 MARCH1 Silent rs9308064 4 164621883 [T/C] NM_001166373 MARCH1 Silent rs17577307 4 164623738 [A/G] NM_001166373 MARCH1 Silent rs1511783 4 164632127 [A/G] NM_001166373 MARCH1 Silent rs1565840 4 164634372 [A/C] NM_001166373 MARCH1 Silent rs17008537 4 164639989 [T/G] NM_001166373 MARCH1 Silent rs9995058 4 164652050 [A/G] NM_001166373 MARCH1 Silent rs6814421 4 164655112 [A/G] NM_001166373 MARCH1 Silent rs7667981 4 164661559 [A/C] NM_001166373 MARCH1 Silent rs6836852 4 164666722 [T/G] NM_001166373 MARCH1 Silent rs9308066 4 164668080 [A/G] NM_001166373 MARCH1 Silent rs10517784 4 164668166 [A/C] NM_001166373 MARCH1 Silent rs6857627 4 164669761 [T/C] NM_001166373 MARCH1 Silent rs2131861 4 164675031 [T/C] NM_001166373 MARCH1 Silent rs10517786 4 164679594 [A/G] NM_001166373 MARCH1 Silent rs4256198 4 164690560 [T/C] NM_001166373 MARCH1 Silent rs1389706 4 164694796 [A/G] NM_001166373 MARCH1 Silent rs1038975 4 164701659 [A/G] NM_001166373 MARCH1 Silent rs8180235 4 164715878 [A/G] NM_001166373 MARCH1 Silent rs12500778 4 164720383 [T/G] NM_001166373 MARCH1 Silent rs12645753 4 164721357 [T/C] NM_001166373 MARCH1 Silent rs1908290 4 164732179 [A/C] NM_001166373 MARCH1 Silent rs2131862 4 164748523 [A/G] NM_001166373 MARCH1 Silent rs17044211 4 164752195 [T/G] NM_001166373 MARCH1 Silent rs1874094 4 164753387 [T/C] NM_001166373 MARCH1 Silent rs11939053 4 164758471 [A/C] NM_001166373 MARCH1 Silent rs7681115 4 164758636 [A/G] NM_001166373 MARCH1 Silent rs2047160 4 164759917 [T/C] NM_001166373 MARCH1 Silent rs1565842 4 164761718 [T/C] NM_001166373 MARCH1 Silent rs7670349 4 164765518 [T/C] NM_001166373 MARCH1 Silent rs7693115 4 164766062 [A/G] NM_001166373 MARCH1 Silent rs11100520 4 164772977 [T/C] NM_001166373 MARCH1 Silent rs923913 4 164777197 [T/C] NM_001166373 MARCH1 Silent rs10517791 4 164779320 [T/C] NM_001166373 MARCH1 Silent rs978402 4 164780120 [T/C] NM_001166373 MARCH1 Silent rs7655259 4 164782515 [A/C] NM_001166373 MARCH1 Silent rs17044246 4 164790801 [A/G] NM_001166373 MARCH1 Silent rs12504215 4 164795529 [T/G] NM_001166373 MARCH1 Silent rs12645283 4 164796501 [T/C] NM_001166373 MARCH1 Silent rs1494284 4 164797386 [T/C] NM_001166373 MARCH1 Silent rs17474536 4 164797407 [A/G] NM_001166373 MARCH1 Silent rs17474585 4 164799338 [A/G] NM_001166373 MARCH1 Silent rs6821574 4 164801854 [A/G] NM_001166373 MARCH1 Silent rs10030506 4 164804576 [A/C] NM_001166373 MARCH1 Silent rs6536757 4 164820243 [A/G] NM_001166373 MARCH1 Silent rs4334707 4 164826828 [T/C] NM_001166373 MARCH1 Silent rs4267695 4 164829104 [T/C] NM_001166373 MARCH1 Silent rs3890761 4 164829751 [T/C] NM_001166373 MARCH1 Silent rs6844489 4 164830114 [A/G] NM_001166373 MARCH1 Silent rs12501935 4 164832145 [A/G] NM_001166373 MARCH1 Silent rs10008162 4 164841877 [A/G] NM_001166373 MARCH1 Silent rs11100528 4 164845121 [A/G] NM_001166373 MARCH1 Silent rs7698990 4 164854370 [A/G] NM_001166373 MARCH1 Silent rs4691940 4 164855278 [T/C] NM_001166373 MARCH1 Silent rs11725690 4 164858736 [T/C] NM_001166373 MARCH1 Silent rs10857365 4 164865947 [T/G] NM_001166373 MARCH1 Silent rs4449375 4 164870129 [T/G] NM_001166373 MARCH1 Silent rs12505619 4 164872277 [T/C] NM_001166373 MARCH1 Silent rs4270550 4 164873243 [T/C] NM_001166373 MARCH1 Silent rs6536764 4 164876016 [T/C] NM_001166373 MARCH1 Silent rs3967462 4 164884738 [T/C] NM_001166373 MARCH1 Silent rs3967463 4 164884894 [A/G] NM_001166373 MARCH1 Silent rs7674531 4 164886060 [A/G] NM_001166373 MARCH1 Silent rs17044337 4 164888443 [T/C] NM_001166373 MARCH1 Silent rs17578295 4 164889372 [T/C] NM_001166373 MARCH1 Silent rs9308069 4 164889887 [A/G] NM_001166373 MARCH1 Silent rs17578337 4 164892274 [T/C] NM_001166373 MARCH1 Silent rs3792673 4 164905719 [A/G] NM_001166373 MARCH1 Silent rs12511868 4 164922532 [T/C] NM_001166373 MARCH1 Silent rs11736201 4 164922631 [T/C] NM_001166373 MARCH1 Silent rs10007601 4 164934874 [A/G] NM_001166373 MARCH1 Silent rs7687757 4 164941060 [A/G] NM_001166373 MARCH1 Silent rs4533720 4 164959804 [A/G] NM_001166373 MARCH1 Silent rs4560357 4 164962875 [A/C] NM_001166373 MARCH1 Silent rs2001227 4 164968164 [A/G] NM_001166373 MARCH1 Silent rs10026455 4 164968546 [A/G] NM_001166373 MARCH1 Silent rs6536779 4 164972162 [T/C] NM_001166373 MARCH1 Silent rs6536780 4 164972256 [A/G] NM_001166373 MARCH1 Silent rs13123163 4 164972450 [T/C] NM_001166373 MARCH1 Silent rs17475275 4 164976680 [A/G] NM_001166373 MARCH1 Silent rs891577 4 164982057 [T/C] NM_001166373 MARCH1 Silent rs1430987 4 164991575 [A/G] NM_001166373 MARCH1 Silent rs971945 4 164992016 [T/G] NM_001166373 MARCH1 Silent rs17475331 4 164994183 [A/G] NM_001166373 MARCH1 Silent rs2321210 4 164996728 [A/G] NM_001166373 MARCH1 Silent rs17044451 4 164997028 [A/C] NM_001166373 MARCH1 Silent rs17044453 4 164997108 [T/G] NM_001166373 MARCH1 Silent rs919574 4 165013565 [A/G] NM_001166373 MARCH1 Silent rs17675820 4 165035159 [T/G] NM_001166373 MARCH1 Silent rs4691956 4 165037553 [T/C] NM_001166373 MARCH1 Silent rs2321305 4 165046587 [T/C] NM_001166373 MARCH1 Silent rs7691235 4 165049116 [A/G] NM_001166373 MARCH1 Silent rs4691961 4 165052223 [A/G] NM_001166373 MARCH1 Silent rs17579243 4 165052304 [T/C] NM_001166373 MARCH1 Silent rs2195697 4 165057027 [A/G] NM_001166373 MARCH1 Silent rs982257 4 165060898 [T/C] NM_001166373 MARCH1 Silent rs1430986 4 165076871 [T/C] NM_001166373 MARCH1 Silent rs1430997 4 165087375 [T/C] NM_001166373 MARCH1 Silent rs17044711 4 165093156 [T/C] NM_001166373 MARCH1 Silent rs2163395 4 165108381 [T/C] NM_001166373 MARCH1 Silent rs1430976 4 165108975 [T/C] NM_001166373 MARCH1 Silent rs28710221 4 165109476 [T/C] NM_001166373 MARCH1 Silent rs17044732 4 165110144 [T/G] NM_001166373 MARCH1 Silent rs1835507 4 165111673 [A/G] NM_001166373 MARCH1 Silent rs1430974 4 165117009 [T/C] NM_001166373 MARCH1 Silent rs2288675 4 165118652 [T/C] NM_001166373,NM_012403 MARCH1,ANP32C EXON Silent,Missense_R71K rs7688298 4 165124259 [T/G] NM_001166373 MARCH1 Silent rs4502640 4 165129362 [A/G] NM_001166373 MARCH1 Silent rs6814420 4 165131350 [A/G] NM_001166373 MARCH1 Silent rs9968537 4 165139274 [T/C] NM_001166373 MARCH1 Silent rs7668234 4 165145428 [T/C] NM_001166373 MARCH1 Silent rs2321373 4 165153650 [T/C] NM_001166373 MARCH1 Silent rs17676292 4 165161269 [T/C] NM_001166373 MARCH1 Silent rs4561891 4 165168921 [A/C] NM_001166373 MARCH1 Silent rs4496540 4 165170408 [A/G] NM_001166373 MARCH1 Silent rs10222965 4 165173550 [A/G] NM_001166373 MARCH1 Silent rs1985065 4 165202419 [T/C] NM_001166373 MARCH1 Silent rs2321377 4 165202724 [T/G] NM_001166373 MARCH1 Silent rs2321376 4 165202782 [A/G] NM_001166373 MARCH1 Silent rs17614438 4 165209309 [T/C] NM_001166373 MARCH1 Silent rs11941402 4 165214649 [A/G] NM_001166373 MARCH1 Silent rs6829588 4 165221971 [T/G] NM_001166373 MARCH1 Silent rs6829484 4 165222183 [A/G] NM_001166373 MARCH1 Silent rs4234967 4 165225070 [A/G] NM_001166373 MARCH1 Silent rs10517805 4 165228232 [A/G] NM_001166373 MARCH1 Silent rs17044891 4 165228672 [T/C] NM_001166373 MARCH1 Silent rs17044895 4 165232273 [A/G] NM_001166373 MARCH1 Silent rs7675835 4 165234545 [T/G] NM_001166373 MARCH1 Silent rs7675571 4 165234678 [A/C] NM_001166373 MARCH1 Silent rs4434204 4 165236998 [T/C] NM_001166373 MARCH1 Silent rs4622958 4 165237207 [A/G] NM_001166373 MARCH1 Silent rs7680916 4 165239116 [T/C] NM_001166373 MARCH1 Silent rs7669453 4 165254752 [T/C] NM_001166373 MARCH1 Silent rs7662252 4 165262655 [T/C] NM_001166373 MARCH1 Silent rs4431170 4 165284574 [A/G] NM_001166373 MARCH1 Silent rs7658861 4 165305889 [T/C] rs1027755 4 165307934 [T/C] rs17483750 4 165314229 [A/G] rs4691974 4 165315996 [A/G] rs1027757 4 165316925 [T/C] rs12510747 4 165317260 [T/C] rs6835711 4 165317732 [A/G] rs10026325 4 165321982 [A/G] rs9994016 4 165322933 [T/C] rs11100552 4 165324215 [T/C] rs1605057 4 165329158 [A/G] rs10004121 4 165329655 [A/C] rs1566934 4 165351210 [T/C] rs4691118 4 165351616 [T/C] rs1505383 4 165353749 [T/G] rs6536816 4 165355188 [A/G] rs11931372 4 165361556 [A/C] rs2874568 4 165364934 [T/C] rs1857798 4 165370126 [T/C] rs1505401 4 165374005 [A/C] rs2089223 4 165386097 [A/G] rs4691121 4 165392008 [T/C] rs1960980 4 165395936 [T/C] rs1394807 4 165400016 [T/G] rs7690372 4 165403992 [T/C] rs12650464 4 165406393 [A/G] rs6834683 4 165409295 [T/C] rs1028212 4 165417351 [T/C] rs1505392 4 165422101 [A/C] rs1505390 4 165425204 [A/G] rs6814836 4 165432628 [A/C] rs13128973 4 165434864 [T/C] rs7654643 4 165440926 [T/C] rs12648459 4 165446252 [A/C] rs6839763 4 165448658 [A/C] rs4597781 4 165452112 [A/G] rs12650712 4 165452601 [T/C] rs10001210 4 165452969 [T/C] rs12508710 4 165456150 [A/G] rs4079693 4 165458952 [T/C] rs6536824 4 165471242 [T/C] rs7692840 4 165483847 [T/C] rs7693270 4 165484115 [A/C] rs1110968 4 165491839 [A/C] rs1528698 4 165492082 [T/C] rs4145327 4 165497383 [A/G] rs17045152 4 165498202 [T/C] rs16999500 4 165498366 [A/G] rs10517809 4 165499278 [T/C] rs1534577 4 165513998 [T/G] rs1534578 4 165514302 [T/C] rs13114673 4 165515604 [T/G] rs17045196 4 165525192 [T/C] rs7691101 4 165526334 [T/C] rs10517812 4 165535872 [T/C] rs17045224 4 165539202 [A/G] rs1528699 4 165542344 [A/C] rs9790550 4 165560063 [T/C] rs17045285 4 165561062 [T/C] rs9991808 4 165561662 [A/G] rs17678153 4 165562187 [A/C] rs6824404 4 165564515 [A/G] rs17678175 4 165564711 [T/C] rs11936514 4 165564737 [T/C] rs12499842 4 165576740 [T/C] rs12651422 4 165578100 [A/G] rs1406365 4 165579891 [A/G] rs11932404 4 165582170 [T/C] rs1528690 4 165585096 [T/C] rs1534581 4 165585482 [A/G] rs12507345 4 165585563 [A/G] rs17045327 4 165587000 [A/G] rs10001932 4 165605068 [A/G] rs7680144 4 165607255 [T/C] rs11724238 4 165607558 [T/C] rs4691129 4 165609979 [T/G] rs6536843 4 165613783 [A/G] rs11935111 4 165614362 [T/C] rs6536847 4 165614650 [A/G] rs9994435 4 165614954 [T/C] rs11939098 4 165617850 [T/G] rs7671059 4 165618268 [A/G] rs17582753 4 165618371 [T/C] rs10000041 4 165621955 [T/G] rs2321760 4 165622160 [T/C] rs6830070 4 165626856 [T/C] rs6536849 4 165627020 [T/C] rs17045377 4 165628168 [T/C] rs1980391 4 165628814 [T/C] rs9308087 4 165629466 [A/C] rs12640091 4 165630021 [T/C] rs13120623 4 165634055 [A/C] rs17485743 4 165638018 [A/G] rs10001077 4 165638228 [T/C] rs7677517 4 165642091 [A/G] rs7696505 4 165644827 [A/G] rs17622247 4 165646228 [A/G] rs1113272 4 165646778 [T/C] rs1881523 4 165647164 [A/G] rs4692007 4 165647923 [A/G] rs17045434 4 165649008 [T/G] rs2056759 4 165649271 [A/C] rs2056760 4 165649300 [A/G] rs4691131 4 165656200 [T/C] rs12502646 4 165658642 [T/C] rs4254724 4 165669160 [A/G] rs10006449 4 165682010 [A/G] NM_001352885 SMIM31 Silent rs4593086 4 165683452 [T/C] NM_001352885 SMIM31 Silent rs17045455 4 165683917 [T/C] NM_001352885 SMIM31 Silent rs11732101 4 165686723 [A/G] NM_001352885 SMIM31 Silent rs11100576 4 165692104 [A/G] NM_001352885 SMIM31 Silent rs10155303 4 165697040 [T/G] NM_001352885 SMIM31 Silent rs13113465 4 165698208 [A/G] NM_001352885 SMIM31 Silent rs6841926 4 165700679 [A/G] NM_001352885 SMIM31 Silent rs4539996 4 165707728 [A/C] NM_001352885 SMIM31 Silent rs7668032 4 165710503 [T/C] NM_001352885 SMIM31 Silent rs13152512 4 165721118 [T/G] NM_001352885 SMIM31 Silent rs17045582 4 165726037 [T/C] rs13126014 4 165726126 [T/C] rs17486421 4 165726289 [T/C] rs4572830 4 165726891 [T/C] rs4518194 4 165728860 [A/G] rs10776539 4 165730192 [T/C] rs17486554 4 165733052 [A/G] rs17486612 4 165736388 [A/G] rs7683083 4 165737589 [A/C] rs6536867 4 165739878 [A/C] rs6536868 4 165740749 [T/C] rs13139212 4 165742640 [T/C] rs11723570 4 165742801 [T/C] rs4339166 4 165744136 [T/C] rs4234980 4 165752701 [T/C] rs10034282 4 165754241 [T/C] rs6827249 4 165756691 [T/C] rs4593087 4 165767472 [T/C] rs4346606 4 165771791 [T/G] rs11732066 4 165774233 [A/G] rs17679574 4 165788675 [A/G] rs17045668 4 165789042 [T/C] rs4459954 4 165793001 [T/C] rs12500546 4 165798986 [A/G] NM_001297550 APELA Silent rs4541465 4 165800154 [T/C] NM_001297550 APELA EXON Synonymous_F53F rs11728450 4 165808470 [A/G] NM_001297550 APELA Silent rs7691785 4 165814359 [A/G] NM_001297550 APELA Silent rs13152225 4 165814775 [A/G] NM_001297550 APELA Silent rs6846439 4 165822659 [T/C] rs6854993 4 165827749 [A/G] rs4429695 4 165836060 [A/G] rs17487218 4 165837436 [T/C] rs17584342 4 165837631 [A/G] rs6852326 4 165839378 [A/G] rs9993897 4 165840481 [A/G] rs6856935 4 165845582 [A/G] rs10006119 4 165849934 [A/G] rs10011691 4 165851057 [T/G] rs3889248 4 165852918 [A/G] rs3889246 4 165853130 [T/G] rs4690795 4 165855463 [T/C] rs4359860 4 165859951 [T/C] rs10020204 4 165869823 [A/G] rs10020142 4 165869919 [T/C] rs28544252 4 165875359 [A/G] rs6834073 4 165875608 [T/C] NM_001012414 TRIM61 EXON Silent rs6848637 4 165877963 [T/C] NM_001012414 TRIM61 Silent rs9762579 4 165877990 [T/G] NM_001012414 TRIM61 Silent rs3733418 4 165878335 [A/G] NM_001012414,NM_153027 TRIM61,FAM218A EXON Silent,Missense_H54R rs10034083 4 165879007 [A/G] NM_001012414,NM_153027 TRIM61,FAM218A EXON Silent,Silent rs10001548 4 165879381 [T/C] NM_001012414,NM_153027 TRIM61,FAM218A EXON Silent,Silent rs8180162 4 165880958 [A/G] NM_001012414 TRIM61 Silent rs13134940 4 165889612 [A/G] NM_001012414 TRIM61 Silent rs13120990 4 165905118 [A/G] rs4691139 4 165908721 [A/G] rs17584656 4 165926286 [A/C] rs11942693 4 165930168 [A/G] rs17045896 4 165931435 [T/C] rs7684974 4 165944299 [A/C] rs6847301 4 165948306 [T/C] rs6536885 4 165950675 [A/G] rs12505213 4 165951703 [A/G] rs10000216 4 165954865 [T/C] NM_152620,NM_001258025 TRIM60,TRIM60 Silent,Silent rs13110766 4 165956628 [A/G] NM_152620,NM_001258025 TRIM60,TRIM60 Silent,Silent rs7654142 4 165964290 [A/G] rs12503351 4 165965120 [A/G] rs6536887 4 165968037 [A/C] rs6828376 4 165971999 [A/G] rs6848914 4 165975122 [T/C] rs6826711 4 165978659 [A/G] rs6819917 4 165981142 [A/G] rs4691148 4 165982775 [A/G] rs13146344 4 165991632 [A/C] rs10027850 4 165995106 [A/G] rs4554024 4 165995461 [A/G] rs6850564 4 165997401 [A/G] NM_001100389 TMEM192 EXON Silent rs9999037 4 166000195 [A/G] NM_001100389 TMEM192 EXON Silent rs12498760 4 166010815 [A/G] NM_001100389 TMEM192 Silent rs4285049 4 166014765 [T/C] NM_001100389 TMEM192 Silent rs4643773 4 166014766 [A/G] NM_001100389 TMEM192 Silent rs12642069 4 166023258 [A/G] NM_001100389 TMEM192 Silent rs6823514 4 166023857 [T/C] NM_001100389 TMEM192 Silent rs17487808 4 166024258 [A/G] NM_001100389 TMEM192 Silent rs4690801 4 166026033 [T/C] NM_001100389 TMEM192 Silent rs17045969 4 166030858 [T/C] NM_001100389 TMEM192 Silent rs2056255 4 166035174 [A/G] rs7661552 4 166040374 [A/G] rs1877536 4 166052268 [T/C] rs4691153 4 166052741 [A/G] rs17623971 4 166055516 [T/G] rs17046014 4 166063422 [A/G] rs10023696 4 166070974 [A/G] rs4691168 4 166072693 [T/C] rs9308098 4 166080237 [T/C] rs10014286 4 166089111 [T/C] rs4234891 4 166090564 [A/G] rs11731244 4 166099190 [T/C] rs4605609 4 166112950 [A/G] rs17585333 4 166114231 [A/G] rs10010241 4 166123245 [T/C] rs17585396 4 166144008 [T/C] NM_001331024,NM_007246,NM_001331023,NM_001161521,NM_001161522 KLHL2,KLHL2,KLHL2,KLHL2,KLHL2 Silent,Silent,Silent,Silent,Silent rs12330937 4 166168419 [A/G] NM_001331024,NM_007246,NM_001331023,NM_001161521,NM_001161522 KLHL2,KLHL2,KLHL2,KLHL2,KLHL2 Silent,Silent,Silent,Silent,Silent rs10517833 4 166170390 [T/C] NM_001331024,NM_007246,NM_001331023,NM_001161521,NM_001161522 KLHL2,KLHL2,KLHL2,KLHL2,KLHL2 Silent,Silent,Silent,Silent,Silent rs10022944 4 166171385 [T/C] NM_001331024,NM_007246,NM_001331023,NM_001161521,NM_001161522 KLHL2,KLHL2,KLHL2,KLHL2,KLHL2 Silent,Silent,Silent,Silent,Silent rs10016586 4 166199390 [T/C] NM_001331024,NM_007246,NM_001331023,NM_001161521,NM_001161522,NR_026575 KLHL2,KLHL2,KLHL2,KLHL2,KLHL2,GK3P EXON Silent,Silent,Silent,Silent,Silent,Silent rs11726531 4 166211057 [T/C] NM_001331024,NM_007246,NM_001331023,NM_001161521,NM_001161522 KLHL2,KLHL2,KLHL2,KLHL2,KLHL2 Silent,Silent,Silent,Silent,Silent rs6536903 4 166237389 [A/G] NM_001331024,NM_007246,NM_001331023,NM_001161521,NM_001161522 KLHL2,KLHL2,KLHL2,KLHL2,KLHL2 Silent,Silent,Silent,Silent,Silent rs10009994 4 166248202 [T/C] rs10019675 4 166251411 [T/C] NM_006745,NM_001017369 MSMO1,MSMO1 Silent,Silent rs17686351 4 166252950 [T/C] NM_006745,NM_001017369 MSMO1,MSMO1 Silent,Silent rs1370689 4 166253765 [T/C] NM_006745,NM_001017369 MSMO1,MSMO1 Silent,Silent rs12504526 4 166258219 [T/C] NM_006745,NM_001017369 MSMO1,MSMO1 Silent,Silent rs1550270 4 166261800 [T/C] NM_006745,NM_001017369 MSMO1,MSMO1 Silent,Silent rs1059209 4 166263213 [A/G] NM_006745,NM_001017369 MSMO1,MSMO1 EXON Silent,Silent rs13918 4 166263919 [A/G] NM_006745,NM_001017369 MSMO1,MSMO1 EXON Silent,Silent rs7667236 4 166267119 [A/G] rs17686529 4 166267383 [A/C] rs12641145 4 166270327 [A/G] rs6828152 4 166279952 [T/G] rs17046348 4 166281891 [A/G] rs12513198 4 166282004 [T/C] rs17488814 4 166283914 [A/G] rs4621390 4 166286171 [A/G] rs6837095 4 166287429 [T/C] rs12501589 4 166289408 [A/C] rs1370682 4 166296379 [A/G] rs1438113 4 166297180 [A/G] rs1583645 4 166298451 [A/G] rs10022413 4 166301778 [A/G] NM_001873 CPE Silent rs6850000 4 166304172 [A/G] NM_001873 CPE Silent rs17489067 4 166306416 [A/C] NM_001873 CPE Silent rs12509669 4 166307302 [A/G] NM_001873 CPE Silent rs9997245 4 166309213 [T/C] NM_001873 CPE Silent rs2322291 4 166310679 [T/C] NM_001873 CPE Silent rs934813 4 166311553 [T/C] NM_001873 CPE Silent rs6536912 4 166315725 [A/G] NM_001873 CPE Silent rs1543915 4 166319702 [A/G] NM_001873 CPE Silent rs6811043 4 166323057 [A/G] NM_001873 CPE Silent rs2053277 4 166327331 [A/G] NM_001873 CPE Silent rs9992011 4 166334446 [A/G] NM_001873 CPE Silent rs1866224 4 166334840 [T/G] NM_001873 CPE Silent rs13125242 4 166342375 [A/G] NM_001873 CPE Silent rs1438119 4 166348346 [T/C] NM_001873 CPE Silent rs7692208 4 166358437 [T/C] NM_001873 CPE Silent rs10517849 4 166358532 [A/G] NM_001873 CPE Silent rs17687250 4 166358572 [T/G] NM_001873 CPE Silent rs4481204 4 166359421 [T/C] NM_001873 CPE Silent rs2083159 4 166365138 [T/C] NM_001873 CPE Silent rs6836074 4 166369281 [A/G] NM_001873 CPE Silent rs6841638 4 166369661 [T/G] NM_001873 CPE Silent rs6842167 4 166370111 [T/C] NM_001873 CPE Silent rs1438114 4 166370156 [T/G] NM_001873 CPE Silent rs10021007 4 166371512 [A/C] NM_001873 CPE Silent rs3775311 4 166386944 [T/C] NM_001873 CPE Silent rs1530042 4 166389558 [T/C] NM_001873 CPE Silent rs1370686 4 166390220 [A/G] NM_001873 CPE Silent rs1370687 4 166390355 [T/C] NM_001873 CPE Silent rs11100614 4 166398831 [T/G] NM_001873 CPE Silent rs11730342 4 166399738 [A/G] NM_001873 CPE Silent rs11737095 4 166403897 [A/G] NM_001873 CPE Silent rs4690821 4 166405584 [T/C] NM_001873 CPE EXON Synonymous_H267H rs3822062 4 166408782 [T/G] NM_001873 CPE Silent rs7692951 4 166416643 [A/G] NM_001873 CPE Silent rs6822718 4 166419478 [A/G] NM_001873 CPE EXON Silent rs2280322 4 166428294 [A/C] rs17046580 4 166431563 [T/C] rs6536916 4 166433829 [A/C] rs7656395 4 166436027 [A/G] rs7699278 4 166438457 [T/C] rs2033765 4 166444375 [A/G] rs2033766 4 166444924 [A/G] rs1837172 4 166448333 [T/G] rs1438118 4 166448674 [A/G] rs2322122 4 166455839 [A/G] rs17503083 4 166456376 [T/C] rs6835679 4 166457130 [A/C] rs17046700 4 166468810 [A/G] rs17046707 4 166469228 [T/C] rs17587610 4 166469496 [A/G] rs9990545 4 166469526 [A/G] rs7654319 4 166471139 [T/C] rs17046724 4 166472139 [T/C] rs17687965 4 166472187 [A/G] rs10028219 4 166472744 [T/C] rs7697374 4 166473571 [T/C] rs17587680 4 166476045 [T/G] rs1914839 4 166481918 [A/C] rs10017297 4 166488615 [T/C] rs1320227 4 166489134 [A/C] rs6843136 4 166494614 [T/C] rs7662154 4 166495142 [A/G] rs4691205 4 166495319 [T/C] rs10006198 4 166497317 [A/G] rs12331357 4 166497693 [A/G] rs17503284 4 166502271 [T/G] rs1320225 4 166508518 [A/G] rs17046824 4 166519866 [A/G] rs9308109 4 166532454 [T/C] rs1246923 4 166533938 [T/C] rs9992328 4 166535178 [T/G] rs1599115 4 166538806 [A/G] rs11721568 4 166547323 [A/G] rs1459506 4 166547603 [A/G] rs11938725 4 166562938 [A/G] rs17588412 4 166565626 [A/G] rs2714834 4 166568732 [A/C] rs2611212 4 166574651 [A/C] rs2611210 4 166575465 [A/G] rs1380348 4 166575815 [A/G] rs2611209 4 166578236 [T/G] rs4691212 4 166585445 [T/G] rs2322264 4 166588048 [T/C] rs2322265 4 166588085 [T/C] rs11932029 4 166588960 [A/G] rs2714807 4 166591321 [T/C] rs17688688 4 166592304 [A/G] rs17504069 4 166592849 [T/C] rs17588573 4 166594188 [A/G] rs2611246 4 166598495 [T/C] rs1459509 4 166602111 [A/G] rs1380355 4 166602585 [T/G] rs2611248 4 166604001 [A/G] rs1870478 4 166605363 [T/G] rs10006288 4 166606107 [T/C] NR_121676 LINC01179 Silent rs2611249 4 166606298 [T/C] NR_121676 LINC01179 Silent rs4691215 4 166606890 [A/G] NR_121676 LINC01179 Silent rs1013356 4 166607504 [T/C] NR_121676 LINC01179 Silent rs17046936 4 166616007 [A/G] NR_121676 LINC01179 Silent rs2611259 4 166619952 [A/G] NR_121676 LINC01179 Silent rs17688831 4 166627996 [T/C] NR_121676 LINC01179 Silent rs2611251 4 166629269 [T/C] NR_121676 LINC01179 Silent rs11936747 4 166631681 [T/C] NR_121676 LINC01179 Silent rs2714850 4 166635425 [T/C] NR_121676 LINC01179 Silent rs7695152 4 166641240 [A/G] NR_121676 LINC01179 Silent rs17632444 4 166642590 [T/C] NR_121676 LINC01179 Silent rs2714825 4 166645636 [A/G] NR_121676 LINC01179 Silent rs17046950 4 166646557 [T/G] NR_121676 LINC01179 Silent rs6816303 4 166655128 [A/G] NR_121676,NR_121677 LINC01179,LOC101928131 Silent,Silent rs716399 4 166659698 [A/G] NR_121676,NR_121677 LINC01179,LOC101928131 EXON Silent,Silent rs10517866 4 166661136 [T/C] NR_121676,NR_121677 LINC01179,LOC101928131 Silent,Silent rs17589098 4 166662954 [T/C] NR_121676,NR_121677 LINC01179,LOC101928131 Silent,Silent rs9308115 4 166663108 [A/G] NR_121676,NR_121677 LINC01179,LOC101928131 Silent,Silent rs17504644 4 166663278 [A/G] NR_121676,NR_121677 LINC01179,LOC101928131 Silent,Silent rs13111857 4 166664618 [A/C] NR_121676 LINC01179 Silent rs2714819 4 166665840 [T/C] NR_121676 LINC01179 Silent rs881821 4 166666480 [T/C] NR_121676 LINC01179 Silent rs922096 4 166667602 [A/G] NR_121676 LINC01179 Silent rs10517867 4 166667833 [T/C] NR_121676 LINC01179 Silent rs7700172 4 166671434 [A/G] NR_121676 LINC01179 Silent rs355196 4 166671834 [A/G] NR_121676 LINC01179 Silent rs191644 4 166674512 [A/G] NR_121676 LINC01179 Silent rs1460053 4 166678420 [T/C] NR_121676 LINC01179 Silent rs10033776 4 166687220 [A/G] rs355171 4 166689405 [T/C] rs355168 4 166691492 [T/C] rs2611830 4 166693657 [A/G] rs12331967 4 166698701 [A/G] rs1563831 4 166699421 [A/G] rs7694605 4 166705990 [A/G] rs17504826 4 166708955 [A/G] rs17632649 4 166709866 [T/C] rs7691783 4 166717673 [T/C] rs10517871 4 166721110 [T/C] rs12648621 4 166726468 [A/G] rs1380582 4 166734132 [T/C] rs7687480 4 166734530 [A/G] rs11100620 4 166747763 [A/G] rs2874792 4 166752233 [A/C] rs17632760 4 166763264 [T/G] rs6816331 4 166764043 [T/G] rs6844820 4 166764589 [A/G] rs6839698 4 166779429 [T/C] rs6536934 4 166785331 [A/G] rs6811456 4 166785679 [T/C] rs719753 4 166793201 [A/G] rs1460072 4 166794829 [T/C] NM_001204760,NM_012464 TLL1,TLL1 EXON Silent,Silent rs1460073 4 166796028 [T/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs2322443 4 166797660 [T/C] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs922145 4 166798262 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs9637646 4 166803528 [T/C] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs2125862 4 166806601 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs17633011 4 166808248 [T/C] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs1460060 4 166815429 [A/C] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs10025830 4 166827370 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs11100626 4 166827464 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs9990589 4 166830580 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs13136952 4 166833808 [T/C] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs7658883 4 166837654 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs1566750 4 166838505 [T/C] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs1018139 4 166848001 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs10517873 4 166850443 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs11942650 4 166854139 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs7654070 4 166854660 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs7679471 4 166854959 [T/C] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs1503292 4 166867875 [A/C] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs17633216 4 166875438 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs7696087 4 166882179 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs10031332 4 166899807 [T/C] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs1503294 4 166905263 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs1393853 4 166908851 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs4691229 4 166915853 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs13123379 4 166921482 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs17505658 4 166928627 [T/C] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs17590218 4 166929102 [A/G] NM_001204760,NM_012464 TLL1,TLL1 EXON Synonymous_E273E,Synonymous_E273E rs1393856 4 166933854 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs17689952 4 166939154 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs10049682 4 166944581 [T/C] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs10003271 4 166945293 [T/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs7675062 4 166945866 [A/G] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs11946108 4 166950151 [T/C] NM_001204760,NM_012464 TLL1,TLL1 Silent,Silent rs17689976 4 166952047 [A/G] NM_001204760,NM_012464 TLL1,TLL1 EXON Silent,Silent rs17047207 4 166956652 [A/G] NM_012464 TLL1 Silent rs17590344 4 166960363 [A/G] NM_012464 TLL1 Silent rs6842100 4 166965201 [A/G] NM_012464 TLL1 Silent rs17505781 4 166967504 [T/C] NM_012464 TLL1 Silent rs9991292 4 166971075 [T/C] NM_012464 TLL1 Silent rs11730398 4 166980214 [T/C] NM_012464 TLL1 Silent rs6536942 4 166986194 [A/G] NM_012464 TLL1 Silent rs2292082 4 166996347 [A/G] NM_012464 TLL1 Silent rs2292083 4 166996414 [A/G] NM_012464 TLL1 Silent rs17047228 4 166997752 [T/C] NM_012464 TLL1 Silent rs13136785 4 167007538 [T/C] NM_012464 TLL1 Silent rs17505880 4 167008090 [A/G] NM_012464 TLL1 Silent rs17047233 4 167008540 [T/G] NM_012464 TLL1 Silent rs1503293 4 167010685 [T/C] NM_012464 TLL1 Silent rs2646915 4 167012063 [A/G] NM_012464 TLL1 Silent rs1995126 4 167014137 [A/G] NM_012464 TLL1 Silent rs4690833 4 167016664 [T/G] NM_012464 TLL1 Silent rs1826956 4 167019072 [T/C] NM_012464 TLL1 Silent rs10018177 4 167020324 [T/C] NM_012464 TLL1 Silent rs2291822 4 167020644 [A/G] NM_012464 TLL1 EXON Missense_T958A rs17047267 4 167020693 [A/C] NM_012464 TLL1 Silent rs2279723 4 167022359 [A/C] NM_012464 TLL1 EXON Silent rs1909083 4 167023760 [T/G] NM_012464 TLL1 EXON Silent rs1497949 4 167024715 [A/G] NM_012464 TLL1 EXON Silent rs1391334 4 167027707 [A/C] rs7694227 4 167036497 [T/G] rs12649030 4 167040095 [A/G] rs904246 4 167044948 [A/G] rs17690647 4 167046795 [A/G] rs1391332 4 167049629 [T/C] rs6825989 4 167054170 [T/C] rs12644376 4 167057477 [T/G] rs6826343 4 167057609 [A/G] rs10003194 4 167068199 [A/G] rs12650012 4 167069396 [T/C] rs10013343 4 167071687 [A/G] rs2874823 4 167074691 [A/C] rs1039178 4 167079178 [A/G] rs13112070 4 167081486 [T/C] rs1497961 4 167082048 [T/G] rs6536948 4 167082557 [A/G] rs2221058 4 167095645 [A/G] rs6838584 4 167099687 [A/G] rs17047336 4 167099916 [A/G] rs28415748 4 167102631 [T/G] rs10028492 4 167104872 [T/C] rs10012204 4 167106550 [A/G] rs1497956 4 167109588 [A/G] rs1497957 4 167110433 [T/C] rs833609 4 167118729 [T/C] rs833605 4 167124766 [T/C] rs353867 4 167125430 [T/C] rs17047381 4 167143385 [T/C] rs11940089 4 167146175 [T/C] rs6855471 4 167150200 [A/G] rs10517883 4 167153670 [T/C] rs17591586 4 167155443 [T/C] rs435881 4 167163302 [T/C] rs1459835 4 167174293 [T/C] rs382628 4 167179581 [T/G] rs421948 4 167185391 [A/G] rs1380497 4 167204445 [T/G] rs895035 4 167222523 [T/C] rs11726963 4 167229729 [A/G] rs425222 4 167232997 [A/G] rs368067 4 167237947 [T/C] rs384968 4 167249784 [A/G] rs7436496 4 167258089 [A/G] rs353077 4 167259818 [A/C] rs410627 4 167263766 [A/G] rs12506355 4 167265509 [A/G] rs7653953 4 167284116 [T/C] rs1982582 4 167287685 [A/G] rs1080788 4 167300345 [A/G] rs1565649 4 167305701 [A/C] rs2639302 4 167309607 [A/G] rs17644454 4 167310277 [A/G] rs1492533 4 167310371 [A/G] rs1565650 4 167321777 [A/C] rs1011872 4 167346551 [A/G] rs1388879 4 167351495 [T/C] rs1492523 4 167352346 [T/C] rs1602681 4 167356733 [A/G] rs6845532 4 167366409 [A/G] rs11100648 4 167366750 [T/C] rs4596200 4 167368812 [A/G] rs13141694 4 167372087 [T/G] rs1492539 4 167383599 [A/G] rs17047646 4 167395297 [T/C] rs1492524 4 167399307 [A/C] rs10857379 4 167400016 [A/G] rs993097 4 167407097 [A/G] rs11100652 4 167408477 [T/C] rs992021 4 167421242 [T/C] rs978230 4 167422116 [T/C] rs12504728 4 167423956 [A/G] rs17644709 4 167425798 [T/C] rs10034660 4 167437817 [T/C] rs875441 4 167448941 [T/G] rs6826162 4 167450233 [T/C] rs12506794 4 167454287 [T/C] rs11941399 4 167455493 [A/G] rs2131252 4 167460285 [T/C] rs7439050 4 167488592 [T/G] rs11937908 4 167507503 [A/G] rs4691299 4 167514725 [T/G] rs6536987 4 167528623 [A/G] rs28840815 4 167529635 [T/C] rs7673384 4 167540460 [T/C] rs7673076 4 167547429 [A/G] rs10001950 4 167550669 [T/G] rs10034869 4 167550780 [T/C] rs6822910 4 167552158 [A/G] rs7663736 4 167555259 [T/G] rs28391069 4 167559106 [T/C] rs28713613 4 167571068 [A/G] rs10007017 4 167589994 [T/C] rs10032330 4 167594972 [A/G] rs3924566 4 167602105 [A/G] rs7434449 4 167602281 [A/C] rs7692681 4 167607492 [T/C] rs7661107 4 167607726 [T/C] rs10517900 4 167611941 [A/G] rs6553485 4 167622160 [A/G] rs7674577 4 167625748 [A/G] rs12503564 4 167634706 [A/G] rs2198738 4 167635674 [A/G] rs17052538 4 167644235 [T/C] rs10009186 4 167644949 [T/C] rs13109075 4 167645029 [T/C] rs4860006 4 167647323 [A/G] rs4859971 4 167648055 [T/C] rs2198737 4 167649165 [A/G] rs11943562 4 167652786 [T/C] rs3762244 4 167655482 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7695294 4 167655803 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17597712 4 167655962 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7681289 4 167659338 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7678726 4 167661584 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7691894 4 167663664 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2318485 4 167664591 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2198736 4 167671562 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7689440 4 167685213 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs897511 4 167695661 [T/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6817936 4 167698248 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17052594 4 167698563 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7698457 4 167699942 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7698841 4 167700120 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17052596 4 167704517 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10517903 4 167711854 [A/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1551491 4 167727136 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2198743 4 167738464 [T/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1023875 4 167738944 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs921856 4 167745216 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17701990 4 167749783 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7669089 4 167753460 [A/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7698485 4 167760175 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs897514 4 167776873 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4859997 4 167785513 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7440269 4 167789207 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7672200 4 167790958 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10014842 4 167812520 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10517908 4 167817905 [T/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12649447 4 167822014 [A/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17645839 4 167837678 [T/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6846723 4 167837707 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10020692 4 167843608 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs8180142 4 167844096 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6828808 4 167853560 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6851188 4 167857369 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12644678 4 167864930 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6823924 4 167866712 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7682844 4 167867095 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7678090 4 167881906 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17599192 4 167891387 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1896479 4 167899470 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1593770 4 167902573 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2703841 4 167907991 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9996703 4 167908627 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1896481 4 167908657 [T/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1863782 4 167914437 [A/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9685645 4 167921525 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 EXON Missense_I109V,Missense_I61V,Silent,Missense_I112V,Silent,Missense_I20V,Missense_I109V,Silent,Missense_I109V rs10012667 4 167921964 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17646122 4 167925272 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6553490 4 167933010 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2703842 4 167938604 [A/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7685624 4 167943152 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1427624 4 167953146 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17052875 4 167955849 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6818745 4 167956606 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7660050 4 167959369 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10023610 4 167976092 [A/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13137632 4 167982046 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6829378 4 167995689 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1427635 4 167999350 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17599740 4 168003155 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7688165 4 168008751 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11939479 4 168022694 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1579404 4 168029135 [A/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs815213 4 168034257 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs815212 4 168036224 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs815216 4 168038730 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10517917 4 168039224 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7435823 4 168044726 [T/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13125626 4 168052793 [A/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12498755 4 168055022 [T/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12640303 4 168056478 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1529397 4 168071197 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17703374 4 168080117 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10017958 4 168084157 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10029237 4 168098935 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7667846 4 168100489 [A/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13143783 4 168131137 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10022799 4 168131448 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9996196 4 168136671 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9312517 4 168139380 [A/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10517927 4 168147524 [T/G] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6850485 4 168150023 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7657608 4 168154181 [T/C] NM_001204356,NM_001204352,NM_001204355,NM_016950,NM_001204353,NM_001204354,NM_001040159,NM_001251967,NM_001204358 SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3,SPOCK3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17600543 4 168162185 [A/G] rs6833251 4 168166789 [T/C] rs17053127 4 168169259 [T/C] rs13113987 4 168172399 [A/G] rs7694278 4 168175697 [A/C] rs10517930 4 168180681 [T/C] rs4266319 4 168187191 [A/G] rs13117708 4 168191092 [A/C] rs35520897 4 168204564 [T/C] rs10004837 4 168211052 [A/G] rs2319265 4 168214408 [T/C] rs13116056 4 168216832 [T/C] rs10008779 4 168236901 [A/C] rs7665794 4 168240912 [T/C] rs2319140 4 168252561 [A/C] rs11942633 4 168256202 [A/G] rs11132983 4 168256989 [A/C] rs17703652 4 168259395 [A/G] rs4385095 4 168260187 [A/G] rs13111850 4 168264249 [T/C] rs17053176 4 168272305 [A/C] rs17053183 4 168273744 [A/G] rs2319270 4 168284744 [A/G] rs2319250 4 168288328 [A/G] rs17053204 4 168288641 [A/C] rs2319248 4 168292265 [T/C] rs2319247 4 168292438 [A/G] rs17601255 4 168294218 [A/C] rs2706061 4 168299957 [A/G] rs2252135 4 168301771 [A/G] rs2952429 4 168307924 [A/G] rs17601548 4 168308058 [T/G] rs2706826 4 168316748 [T/C] rs2706825 4 168316848 [T/C] rs3860620 4 168327233 [T/C] rs2706836 4 168334028 [T/C] rs2952482 4 168338506 [A/G] rs12645590 4 168342792 [T/C] rs4449438 4 168345139 [A/G] rs2706845 4 168348637 [T/G] rs4419497 4 168348929 [T/C] rs6553778 4 168351130 [T/C] rs13136714 4 168353430 [T/G] rs2706822 4 168362952 [A/G] rs2319242 4 168364638 [A/C] rs11133037 4 168366518 [T/C] rs6854438 4 168375863 [T/G] rs17053291 4 168390213 [T/C] rs17704183 4 168390470 [A/G] rs17053293 4 168391112 [T/C] rs6817078 4 168391333 [T/G] rs2169736 4 168401003 [T/C] rs6820500 4 168406525 [A/G] rs1600106 4 168414411 [T/C] rs10517942 4 168431604 [T/C] rs2219758 4 168434661 [A/G] rs12645548 4 168437692 [T/C] rs17053332 4 168442929 [A/C] rs1600103 4 168448425 [A/C] rs1518203 4 168450615 [T/G] rs1817389 4 168455386 [T/C] rs7668194 4 168472046 [T/G] rs1878685 4 168472510 [T/C] rs6816291 4 168472966 [T/C] rs6845819 4 168473019 [T/G] rs7672872 4 168478645 [A/G] rs1607341 4 168482184 [T/C] rs992771 4 168485751 [A/G] rs17704359 4 168508173 [A/G] rs1401014 4 168515495 [T/C] rs17053380 4 168520452 [T/C] rs7657818 4 168523786 [A/G] rs7675475 4 168536364 [A/G] rs1401022 4 168536686 [A/G] rs13140381 4 168539717 [A/G] rs2169735 4 168545366 [A/C] rs1356511 4 168545610 [T/G] rs1533547 4 168564107 [A/G] rs12645719 4 168576098 [T/C] rs6850404 4 168576599 [A/C] rs17524463 4 168583227 [T/C] rs7683919 4 168590008 [T/G] rs1533551 4 168593397 [A/C] rs7664708 4 168593787 [A/C] rs2203769 4 168593961 [A/G] rs1518186 4 168594710 [T/C] rs17053475 4 168598025 [T/C] rs6552196 4 168602424 [A/G] rs6816694 4 168610661 [T/C] rs10517954 4 168611058 [T/C] rs17053510 4 168613796 [T/C] rs12647151 4 168615218 [T/G] rs7677082 4 168616720 [A/C] rs9968440 4 168617513 [T/C] rs7690929 4 168621364 [A/G] rs11730375 4 168626439 [T/C] rs10471169 4 168628323 [T/C] rs10016865 4 168631913 [A/C] rs959169 4 168637332 [A/G] rs4331802 4 168656374 [T/G] rs13128223 4 168669808 [A/G] rs6848110 4 168671673 [A/G] rs6552243 4 168679351 [A/G] rs6834993 4 168679456 [A/G] rs10002325 4 168705038 [A/G] rs7691710 4 168716148 [T/C] rs13124475 4 168721503 [A/C] rs2007133 4 168764988 [T/C] rs17525095 4 168768607 [T/C] rs6848226 4 168769039 [A/G] rs304327 4 168793863 [T/C] rs407213 4 168798179 [A/G] rs1847688 4 168807727 [T/C] rs12500312 4 168808600 [A/G] rs1562143 4 168810105 [T/C] rs9994795 4 168815347 [T/C] rs304351 4 168818443 [A/C] rs17525374 4 168818710 [A/G] rs28405731 4 168824192 [A/C] rs10022932 4 168824533 [T/C] rs7682960 4 168829106 [A/G] rs6817742 4 168832046 [T/C] rs6815587 4 168836284 [A/C] rs2166186 4 168841128 [A/G] rs13107574 4 168850375 [A/G] rs17525479 4 168853211 [A/G] rs13140875 4 168857462 [T/C] rs17610208 4 168871037 [T/C] rs304341 4 168893805 [T/C] rs11944180 4 168935601 [T/C] rs13140793 4 168945264 [T/C] rs11943919 4 168955983 [T/G] rs12647740 4 168964452 [T/C] rs11934907 4 168965733 [T/G] rs10006894 4 168967476 [A/G] rs11728448 4 168968218 [A/G] rs11132000 4 168972967 [A/G] rs9999798 4 168977085 [T/C] rs7678466 4 168980017 [T/C] rs11132008 4 168987754 [A/G] rs4443240 4 168994309 [T/G] rs7662898 4 169008885 [A/G] rs6845007 4 169011633 [T/C] rs12646377 4 169017774 [T/G] NM_007193 ANXA10 Silent rs9799627 4 169017909 [A/G] NM_007193 ANXA10 Silent rs2319707 4 169020566 [A/G] NM_007193 ANXA10 Silent rs4692853 4 169032268 [A/G] NM_007193 ANXA10 Silent rs11944588 4 169032483 [A/G] NM_007193 ANXA10 Silent rs7653928 4 169035968 [T/C] NM_007193 ANXA10 Silent rs9991416 4 169041179 [A/G] NM_007193 ANXA10 Silent rs4405980 4 169042167 [A/G] NM_007193 ANXA10 Silent rs7662687 4 169046172 [A/G] NM_007193 ANXA10 Silent rs7699520 4 169049597 [A/G] NM_007193 ANXA10 Silent rs6832786 4 169056777 [T/C] NM_007193 ANXA10 Silent rs6841013 4 169059063 [T/C] NM_007193 ANXA10 Silent rs4518204 4 169062297 [A/G] NM_007193 ANXA10 Silent rs1317046 4 169072888 [A/G] NM_007193 ANXA10 Silent rs11936562 4 169076192 [A/G] NM_007193 ANXA10 Silent rs6836994 4 169083694 [A/C] NM_007193 ANXA10 EXON Missense_M71L rs4405979 4 169086441 [A/G] NM_007193 ANXA10 EXON Synonymous_S148S rs978726 4 169090279 [A/G] NM_007193 ANXA10 Silent rs477897 4 169098914 [A/G] NM_007193 ANXA10 EXON Synonymous_T168T rs10024092 4 169098984 [T/G] NM_007193 ANXA10 Silent rs642729 4 169107212 [T/C] NM_007193 ANXA10 Silent rs3828561 4 169108472 [A/C] NM_007193 ANXA10 Silent rs17053750 4 169108921 [A/G] rs7690036 4 169109893 [T/C] rs670905 4 169112742 [A/C] rs644911 4 169123534 [A/C] rs602731 4 169126043 [A/G] rs11722969 4 169133758 [A/G] rs9685229 4 169134541 [T/C] rs17611096 4 169138291 [T/C] NM_017631 DDX60 Silent rs17611110 4 169140553 [T/C] NM_017631 DDX60 Silent rs1878313 4 169141810 [T/C] NM_017631 DDX60 EXON Missense_I1679V rs17053806 4 169142892 [T/G] NM_017631 DDX60 EXON Synonymous_V1655V rs2271712 4 169145579 [T/C] NM_017631 DDX60 Silent rs7691168 4 169155948 [A/G] NM_017631 DDX60 Silent rs6552559 4 169158471 [T/G] NM_017631 DDX60 EXON Synonymous_G1459G rs12510170 4 169161977 [T/C] NM_017631 DDX60 Silent rs6857534 4 169174299 [T/C] NM_017631 DDX60 Silent rs17053871 4 169175069 [A/G] NM_017631 DDX60 Silent rs6552572 4 169176378 [T/C] NM_017631 DDX60 Silent rs1671317 4 169181574 [T/C] NM_017631 DDX60 Silent rs958769 4 169185207 [A/G] NM_017631 DDX60 Silent rs576619 4 169188780 [T/C] NM_017631 DDX60 EXON Missense_I998V rs10006979 4 169191255 [T/C] NM_017631 DDX60 Silent rs593342 4 169191536 [A/C] NM_017631 DDX60 Silent rs565824 4 169192795 [A/G] NM_017631 DDX60 Silent rs550625 4 169197297 [T/C] NM_017631 DDX60 EXON Missense_V672M rs665375 4 169202696 [A/G] NM_017631 DDX60 Silent rs17611592 4 169217578 [A/G] NM_017631 DDX60 Silent rs2684370 4 169236274 [A/G] NM_017631 DDX60 Silent rs7696914 4 169236360 [T/C] NM_017631 DDX60 Silent rs497179 4 169237664 [A/G] NM_017631 DDX60 Silent rs10019458 4 169240043 [T/C] rs6843318 4 169243273 [A/G] rs522085 4 169244726 [A/G] rs559203 4 169255850 [T/C] rs12648381 4 169258865 [T/G] rs17539821 4 169278400 [T/C] NM_001012967,NM_001345927 DDX60L,DDX60L EXON Silent,Silent rs11736382 4 169279364 [T/C] NM_001012967,NM_001345927 DDX60L,DDX60L EXON Synonymous_L1685L,Synonymous_L1686L rs3749494 4 169282187 [A/G] NM_001012967,NM_001345927 DDX60L,DDX60L Silent,Silent rs10005156 4 169284960 [T/C] NM_001012967,NM_001345927 DDX60L,DDX60L Silent,Silent rs13145897 4 169293182 [A/G] NM_001012967,NM_001345927 DDX60L,DDX60L Silent,Silent rs13133439 4 169294859 [T/C] NM_001012967,NM_001345927 DDX60L,DDX60L EXON Synonymous_G1578G,Synonymous_G1579G rs12509086 4 169297132 [A/G] NM_001012967,NM_001345927 DDX60L,DDX60L Silent,Silent rs17540046 4 169297397 [A/G] NM_001012967,NM_001345927 DDX60L,DDX60L Silent,Silent rs2046770 4 169298000 [T/C] NM_001012967,NM_001345927 DDX60L,DDX60L Silent,Silent rs902003 4 169306106 [A/C] NM_001012967,NM_001345927 DDX60L,DDX60L Silent,Silent rs3762853 4 169307654 [A/G] NM_001012967,NM_001345927 DDX60L,DDX60L Silent,Silent rs1994530 4 169311333 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L EXON Silent,Silent,Silent rs4692654 4 169314140 [A/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs3749499 4 169315760 [A/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L EXON Missense_E1222D,Missense_E1223D,Missense_E1223D rs17612144 4 169315867 [A/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs3828494 4 169316026 [A/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs9284933 4 169323978 [A/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs6853665 4 169324016 [A/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs17540213 4 169325233 [T/A] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L EXON Missense_S1080C,Missense_S1080C,Missense_S1080C rs17540220 4 169328289 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs1387330 4 169329321 [A/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs17612290 4 169329930 [A/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs11942034 4 169331408 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs4692661 4 169336662 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L EXON Missense_Y959C,Missense_Y959C,Missense_Y959C rs3762848 4 169337313 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs1565266 4 169337400 [A/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs1565265 4 169337545 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs6848102 4 169338127 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs6552758 4 169338131 [T/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs1963569 4 169338520 [A/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs1021318 4 169340639 [A/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs1000775 4 169343522 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs1021317 4 169346189 [A/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs2246498 4 169346949 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs2712119 4 169347712 [A/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs2319850 4 169348404 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L EXON Missense_A583T,Missense_A583T,Missense_A583T rs2712120 4 169348435 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L EXON Synonymous_K572K,Synonymous_K572K,Synonymous_K572K rs17540470 4 169349568 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs2319851 4 169358017 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs11728342 4 169361897 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs13151700 4 169362557 [C/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L EXON Missense_V409L,Missense_V409L,Missense_V409L rs12507582 4 169369920 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L EXON Missense_C336Y,Missense_C336Y,Missense_C336Y rs2634951 4 169372709 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs17612630 4 169382991 [A/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L EXON Synonymous_T155T,Synonymous_T155T,Synonymous_T155T rs1387324 4 169387941 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs10004447 4 169390717 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs12331193 4 169394314 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs7678260 4 169394695 [A/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs2029385 4 169396512 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs17054232 4 169396757 [A/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs10012902 4 169397830 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs2634959 4 169398762 [A/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs10002007 4 169399560 [T/C] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs13353710 4 169401199 [A/G] NM_001012967,NM_001345927,NM_001291510 DDX60L,DDX60L,DDX60L Silent,Silent,Silent rs2029386 4 169407947 [A/G] rs2243724 4 169408390 [A/C] rs17650332 4 169413936 [A/G] rs6819953 4 169414429 [T/G] rs2712134 4 169417232 [A/C] rs11132268 4 169419690 [A/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs2712135 4 169419849 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs2712149 4 169422705 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs2002727 4 169425016 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs4692943 4 169425339 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs10517996 4 169425778 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs17054263 4 169426262 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs1962363 4 169428546 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs10517999 4 169428821 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs10518001 4 169429657 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs6857497 4 169429928 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs10440507 4 169430365 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs7673220 4 169433333 [T/C] NM_001166108,NM_016081 PALLD,PALLD EXON Synonymous_D226D,Synonymous_D226D rs6841109 4 169434602 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs11735275 4 169439108 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs11939452 4 169439280 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs11132283 4 169439902 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs9312333 4 169448628 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs17054309 4 169454317 [A/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs13145788 4 169457246 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs1986369 4 169457744 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs10023820 4 169459736 [T/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs6836618 4 169464134 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs6857016 4 169474972 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs17707180 4 169475264 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs11132322 4 169476590 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs17541413 4 169481874 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs10518011 4 169482396 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs10022111 4 169484303 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs10015043 4 169485237 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs10004025 4 169491370 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs1962022 4 169492567 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs7693542 4 169494427 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs7668720 4 169499240 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs4458418 4 169499863 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs17650886 4 169500402 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs6815330 4 169503531 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs17650892 4 169504186 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs17054360 4 169505090 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs2874112 4 169506877 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs17707379 4 169509103 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs2319909 4 169509436 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs9884890 4 169510892 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs17054375 4 169514438 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs4144994 4 169517130 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs4132492 4 169523335 [T/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs4371580 4 169526903 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs17054390 4 169530181 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs4389538 4 169530339 [T/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs12647503 4 169532292 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs12650216 4 169532319 [T/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs17707568 4 169537189 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs2723687 4 169538426 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs2710851 4 169538443 [T/C] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs2723688 4 169539216 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs3109799 4 169549646 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs2723696 4 169551542 [A/G] NM_001166108,NM_016081 PALLD,PALLD Silent,Silent rs2723698 4 169558119 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs12643131 4 169567817 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs2723704 4 169569729 [T/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs17614077 4 169571481 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs10010321 4 169577535 [T/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs12642267 4 169579967 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs17054449 4 169580501 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs4314247 4 169584060 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs6839585 4 169585678 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs6846708 4 169586731 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs12649186 4 169588252 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs2723705 4 169589214 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs2723708 4 169592669 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs11933816 4 169595421 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs2710824 4 169596133 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs13137200 4 169596649 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs6832582 4 169599633 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs17054465 4 169605174 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs4692947 4 169605918 [A/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs10018408 4 169606336 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs10021155 4 169606881 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs4260495 4 169612528 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs4425335 4 169618128 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs6842732 4 169618430 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs4280700 4 169618568 [T/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs12649675 4 169622650 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs4635780 4 169634434 [T/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs7670597 4 169639326 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs9884230 4 169641425 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs4599370 4 169641509 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs7697688 4 169643079 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs11132434 4 169644844 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs17542430 4 169644989 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs17708122 4 169646207 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs7659644 4 169656656 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs1500800 4 169657096 [T/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs6811238 4 169663615 [T/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs7656460 4 169664679 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs6857155 4 169667766 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs6817535 4 169670530 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs6852874 4 169676032 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs17542654 4 169685036 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs12499664 4 169685812 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs17542688 4 169689516 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs17708307 4 169692342 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs4692948 4 169692626 [A/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs12510663 4 169692809 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs7679564 4 169693353 [T/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs2247733 4 169694079 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs999958 4 169698873 [A/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs7688994 4 169703162 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs17614733 4 169703442 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs1542869 4 169717641 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs9312367 4 169718700 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs11733873 4 169718848 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs6856453 4 169722338 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs17614822 4 169722992 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs1875297 4 169725009 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs1875296 4 169725161 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs7681510 4 169725605 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs13129779 4 169726027 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs6822195 4 169728142 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs6854137 4 169728236 [T/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs1566499 4 169732171 [A/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs1566498 4 169732320 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs4692949 4 169733334 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs10005789 4 169740931 [A/G] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs1392750 4 169745078 [T/C] NM_001166108,NM_016081,NM_001166109 PALLD,PALLD,PALLD Silent,Silent,Silent rs2133911 4 169754830 [A/G] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs867901 4 169762454 [A/G] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs973990 4 169763252 [T/C] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs12643033 4 169764312 [T/G] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs1318822 4 169764489 [T/C] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs3811758 4 169765728 [T/C] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs7688533 4 169766595 [A/G] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs1392751 4 169766963 [A/G] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs4692553 4 169769793 [T/C] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs13114906 4 169771612 [A/G] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs6852229 4 169773066 [A/G] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs7682426 4 169779025 [T/C] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs867632 4 169781253 [A/G] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs7690353 4 169788148 [A/G] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs12643097 4 169801952 [A/G] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs1875299 4 169812782 [A/C] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs2047633 4 169815472 [T/G] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs1566496 4 169819067 [A/C] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs6819031 4 169827618 [A/G] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs1500795 4 169828862 [T/C] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs4396955 4 169845720 [T/C] NM_001166108,NM_016081,NM_001166109,NM_001166110 PALLD,PALLD,PALLD,PALLD Silent,Silent,Silent,Silent rs1115717 4 169863970 [A/G] rs17543378 4 169874986 [A/C] rs4446276 4 169889068 [T/C] rs10518037 4 169899023 [T/C] rs17054604 4 169909593 [A/G] NM_032783 CBR4 EXON Silent rs898002 4 169917245 [T/C] NM_032783 CBR4 Silent rs2877380 4 169928842 [T/G] NM_032783 CBR4 EXON Missense_L70M rs1551612 4 169931752 [A/G] rs17615362 4 169934087 [A/G] rs17054653 4 169934459 [T/C] rs1458292 4 169935881 [A/G] rs2331453 4 169936671 [A/G] rs17054666 4 169947762 [A/G] rs13434426 4 169948102 [A/G] rs2331452 4 169951395 [A/C] rs13147728 4 169960188 [T/G] rs2331548 4 169962604 [A/G] rs4692691 4 169967051 [T/G] rs7664949 4 169969076 [T/C] rs752625 4 169971917 [A/G] rs10009678 4 169972311 [T/C] rs7673669 4 169972982 [T/C] rs7686225 4 169974756 [T/C] rs12498384 4 169977902 [A/G] rs17054702 4 169979856 [T/C] rs17626424 4 169981893 [A/G] rs17543834 4 169984410 [A/G] rs4692693 4 169985016 [T/G] rs4692561 4 169990206 [A/C] rs4692694 4 169991158 [A/G] rs4692695 4 169992206 [A/G] rs12505635 4 169992966 [T/C] rs10012798 4 169993004 [T/C] rs11736883 4 169994701 [T/G] rs922014 4 169997898 [T/C] rs17658335 4 169998230 [A/G] rs7688048 4 170003479 [A/G] rs6844814 4 170008947 [A/G] rs17626617 4 170013910 [T/C] rs2608852 4 170014786 [T/C] rs13139803 4 170015977 [T/C] NM_020870 SH3RF1 EXON Silent rs2706747 4 170017508 [T/C] NM_020870 SH3RF1 EXON Silent rs6553418 4 170019039 [A/G] NM_020870 SH3RF1 Silent rs17626658 4 170030587 [T/C] NM_020870 SH3RF1 Silent rs10017472 4 170037323 [A/G] NM_020870 SH3RF1 Silent rs3811813 4 170037572 [A/G] NM_020870 SH3RF1 EXON Missense_P663S rs10019521 4 170043134 [A/G] NM_020870 SH3RF1 Silent rs3811815 4 170043589 [T/C] NM_020870 SH3RF1 Silent rs7655930 4 170059119 [A/G] NM_020870 SH3RF1 Silent rs6553420 4 170059252 [A/G] NM_020870 SH3RF1 Silent rs9684601 4 170064574 [A/G] NM_020870 SH3RF1 Silent rs10866333 4 170068750 [A/G] NM_020870 SH3RF1 Silent rs7660681 4 170072418 [A/G] NM_020870 SH3RF1 Silent rs7666351 4 170072881 [A/C] NM_020870 SH3RF1 Silent rs10518039 4 170077789 [A/G] NM_020870 SH3RF1 EXON Synonymous_Y145Y rs7689533 4 170081113 [T/C] NM_020870 SH3RF1 Silent rs13118066 4 170092033 [A/C] NM_020870 SH3RF1 Silent rs9991235 4 170093506 [A/G] NM_020870 SH3RF1 Silent rs17593695 4 170109896 [T/C] NM_020870 SH3RF1 Silent rs2706740 4 170115171 [A/G] NM_020870 SH3RF1 Silent rs2660416 4 170133911 [T/C] NM_020870 SH3RF1 Silent rs6847734 4 170138985 [T/C] NM_020870 SH3RF1 Silent rs7698807 4 170145050 [A/G] NM_020870 SH3RF1 Silent rs1876398 4 170146632 [A/G] NM_020870 SH3RF1 Silent rs2660404 4 170149701 [A/C] NM_020870 SH3RF1 Silent rs2331608 4 170153297 [T/C] NM_020870 SH3RF1 Silent rs6814821 4 170158097 [T/C] NM_020870 SH3RF1 Silent rs6830844 4 170170924 [T/C] NM_020870 SH3RF1 Silent rs1507166 4 170175324 [A/G] NM_020870 SH3RF1 Silent rs13130049 4 170182897 [T/G] NM_020870 SH3RF1 Silent rs17710102 4 170198039 [T/C] rs7683893 4 170203367 [T/C] rs13112591 4 170203848 [A/C] rs992939 4 170208954 [A/G] rs6841955 4 170212576 [T/C] rs10009607 4 170212887 [T/G] rs4692709 4 170228549 [T/C] rs4295223 4 170230174 [A/G] rs12511773 4 170230419 [T/C] rs6815837 4 170233946 [A/G] rs11736716 4 170235438 [T/C] rs10017932 4 170237660 [A/G] rs10002073 4 170245260 [A/C] rs13435077 4 170252904 [T/C] rs7671546 4 170262104 [A/G] rs4535301 4 170263443 [T/G] rs13106653 4 170266486 [T/C] rs6845753 4 170286096 [A/G] rs4331740 4 170291213 [T/G] rs11132803 4 170297709 [A/G] rs10866338 4 170302498 [T/C] rs4349564 4 170305035 [A/C] rs4263355 4 170310446 [T/C] rs6851355 4 170310457 [T/C] rs4544675 4 170312589 [A/G] rs13212 4 170314951 [T/C] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 EXON Silent,Silent,Silent,Silent,Silent rs1129694 4 170315166 [A/G] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 EXON Silent,Silent,Silent,Silent,Silent rs7687276 4 170319471 [A/G] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 Silent,Silent,Silent,Silent,Silent rs12644838 4 170338453 [T/C] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 Silent,Silent,Silent,Silent,Silent rs7655924 4 170345893 [T/C] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 EXON Synonymous_P983P,Synonymous_P1011P,Synonymous_P939P,Synonymous_P967P,Synonymous_P914P rs7666939 4 170360674 [T/C] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 Silent,Silent,Silent,Silent,Silent rs4334719 4 170362151 [T/C] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 Silent,Silent,Silent,Silent,Silent rs4353861 4 170367235 [T/C] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 Silent,Silent,Silent,Silent,Silent rs17544885 4 170429402 [T/C] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 EXON Synonymous_E582E,Synonymous_E610E,Synonymous_E538E,Synonymous_E566E,Synonymous_E513E rs6846589 4 170432106 [T/G] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 Silent,Silent,Silent,Silent,Silent rs6553441 4 170448464 [T/C] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 Silent,Silent,Silent,Silent,Silent rs6856378 4 170451435 [A/G] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 Silent,Silent,Silent,Silent,Silent rs11941560 4 170452770 [A/G] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 Silent,Silent,Silent,Silent,Silent rs17054997 4 170459833 [A/C] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 Silent,Silent,Silent,Silent,Silent rs11722114 4 170462979 [T/C] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 Silent,Silent,Silent,Silent,Silent rs10001274 4 170471183 [T/C] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 Silent,Silent,Silent,Silent,Silent rs10032225 4 170486710 [A/G] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 Silent,Silent,Silent,Silent,Silent rs4235024 4 170511551 [T/G] NM_012224,NM_001199397,NM_001199400,NM_001199398,NM_001199399 NEK1,NEK1,NEK1,NEK1,NEK1 Silent,Silent,Silent,Silent,Silent rs11935607 4 170540000 [A/G] rs3797041 4 170541041 [T/C] rs12331279 4 170542698 [A/G] NM_001243372,NM_001829,NM_173872 CLCN3,CLCN3,CLCN3 Silent,Silent,Silent rs7682861 4 170549443 [A/G] NM_001243372,NM_001829,NM_173872 CLCN3,CLCN3,CLCN3 Silent,Silent,Silent rs11937417 4 170549935 [A/G] NM_001243372,NM_001829,NM_173872 CLCN3,CLCN3,CLCN3 Silent,Silent,Silent rs10023330 4 170558032 [T/C] NM_001243372,NM_001829,NM_173872 CLCN3,CLCN3,CLCN3 Silent,Silent,Silent rs17659581 4 170559440 [T/C] NM_001243372,NM_001829,NM_173872 CLCN3,CLCN3,CLCN3 Silent,Silent,Silent rs10866341 4 170568789 [A/G] NM_001243372,NM_001829,NM_173872 CLCN3,CLCN3,CLCN3 Silent,Silent,Silent rs7697855 4 170575851 [T/C] NM_001243372,NM_001829,NM_173872 CLCN3,CLCN3,CLCN3 Silent,Silent,Silent rs17627811 4 170579002 [A/C] NM_001243372,NM_001829,NM_173872 CLCN3,CLCN3,CLCN3 Silent,Silent,Silent rs17627829 4 170579585 [A/G] NM_001243372,NM_001829,NM_173872 CLCN3,CLCN3,CLCN3 Silent,Silent,Silent rs35899341 4 170586793 [A/G] NM_001243372,NM_001829,NM_173872,NM_001243374 CLCN3,CLCN3,CLCN3,CLCN3 Silent,Silent,Silent,Silent rs12511877 4 170590389 [A/G] NM_001243372,NM_001829,NM_173872,NM_001243374 CLCN3,CLCN3,CLCN3,CLCN3 Silent,Silent,Silent,Silent rs13435853 4 170590989 [A/G] NM_001243372,NM_001829,NM_173872,NM_001243374 CLCN3,CLCN3,CLCN3,CLCN3 Silent,Silent,Silent,Silent rs10222938 4 170598148 [A/G] NM_001243372,NM_001829,NM_173872,NM_001243374 CLCN3,CLCN3,CLCN3,CLCN3 Silent,Silent,Silent,Silent rs11939557 4 170609251 [T/C] NM_001243372,NM_001829,NM_173872,NM_001243374 CLCN3,CLCN3,CLCN3,CLCN3 Silent,Silent,Silent,Silent rs10520163 4 170626552 [T/C] NM_001243372,NM_001829,NM_173872,NM_001243374 CLCN3,CLCN3,CLCN3,CLCN3 Silent,Silent,Silent,Silent rs17055101 4 170634390 [T/C] NM_001243372,NM_001829,NM_173872,NM_001243374 CLCN3,CLCN3,CLCN3,CLCN3 EXON Synonymous_I743I,Synonymous_I770I,Synonymous_I770I,Synonymous_I743I rs1010713 4 170634408 [A/G] NM_001243372,NM_001829,NM_173872,NM_001243374 CLCN3,CLCN3,CLCN3,CLCN3 EXON Synonymous_R749R,Synonymous_R776R,Synonymous_R776R,Synonymous_R749R rs13550 4 170642781 [T/C] NM_001243372,NM_001829,NM_173872,NM_001243374 CLCN3,CLCN3,CLCN3,CLCN3 EXON Silent,Silent,Silent,Silent rs4692742 4 170651811 [T/C] NM_017867 HPF1 Silent rs17080034 4 170656677 [A/C] NM_017867 HPF1 Silent rs17055114 4 170658731 [A/G] NM_017867 HPF1 Silent rs7684296 4 170662275 [T/C] NM_017867 HPF1 Silent rs1047642 4 170663235 [T/C] NM_017867 HPF1 EXON Missense_R174K rs2331721 4 170668031 [T/C] NM_017867 HPF1 Silent rs10020331 4 170670592 [T/C] NM_017867 HPF1 Silent rs17055122 4 170675646 [A/C] NM_017867 HPF1 Silent rs13122912 4 170676328 [A/G] NM_017867 HPF1 Silent rs9312454 4 170688979 [A/G] rs7673018 4 170690690 [T/C] rs4692749 4 170693902 [T/G] rs4692750 4 170695748 [A/C] rs10014683 4 170704163 [T/C] rs4692751 4 170706770 [A/G] rs6553459 4 170713166 [A/G] rs11132816 4 170717008 [A/G] rs6835612 4 170719215 [T/C] rs1995306 4 170737078 [T/C] rs1995305 4 170737119 [T/G] rs4072504 4 170740266 [T/G] rs10866343 4 170754412 [A/G] rs10015829 4 170762017 [A/G] rs13110366 4 170770486 [A/G] rs4692758 4 170773712 [A/G] rs7659128 4 170778068 [T/C] rs6810718 4 170778702 [A/C] rs6811785 4 170782760 [A/G] rs6840086 4 170787254 [T/G] rs12642650 4 170801162 [A/G] rs10004128 4 170801265 [T/C] rs11132826 4 170801990 [T/C] rs4077273 4 170807597 [T/C] rs11132829 4 170814998 [T/C] rs4076940 4 170818615 [T/C] rs12643868 4 170824005 [A/G] rs10002607 4 170826315 [A/G] rs10004720 4 170832177 [A/C] rs4634183 4 170834427 [A/G] rs2002221 4 170842930 [A/G] NR_037878 LINC02275 Silent rs2955269 4 170848562 [T/G] NR_037878 LINC02275 Silent rs10010614 4 170857504 [T/C] NR_037878 LINC02275 Silent rs7684116 4 170859150 [A/G] NR_037878 LINC02275 Silent rs4692771 4 170867341 [T/C] NR_037878 LINC02275 Silent rs10008105 4 170872226 [T/C] NR_037878 LINC02275 Silent rs2955267 4 170875915 [A/C] NR_037878 LINC02275 Silent rs6553477 4 170877933 [T/C] NR_037878 LINC02275 Silent rs6821170 4 170880049 [T/C] NR_037878 LINC02275 Silent rs11723530 4 170880883 [A/G] NR_037878 LINC02275 Silent rs13137856 4 170883505 [T/C] NR_037878 LINC02275 Silent rs4692775 4 170887367 [T/C] NR_037878 LINC02275 Silent rs3797042 4 170892618 [A/G] NR_037878 LINC02275 Silent rs13118628 4 170894451 [T/C] NR_037878 LINC02275 Silent rs4588426 4 170895510 [T/C] NR_037878 LINC02275 Silent rs6553482 4 170896626 [T/C] NR_037878 LINC02275 Silent rs13114528 4 170897935 [A/C] rs17055338 4 170900925 [A/C] rs10033615 4 170901019 [T/C] rs9684599 4 170904165 [A/C] rs17055345 4 170906940 [A/C] rs6553483 4 170908445 [A/G] NM_001009554,NM_001301648,NM_001301647,NM_021647 MFAP3L,MFAP3L,MFAP3L,MFAP3L EXON Silent,Silent,Silent,Silent rs6835378 4 170909908 [T/C] NM_001009554,NM_001301648,NM_001301647,NM_021647 MFAP3L,MFAP3L,MFAP3L,MFAP3L EXON Silent,Silent,Silent,Silent rs3797044 4 170910203 [T/C] NM_001009554,NM_001301648,NM_001301647,NM_021647 MFAP3L,MFAP3L,MFAP3L,MFAP3L EXON Silent,Silent,Silent,Silent rs4320103 4 170910322 [A/G] NM_001009554,NM_001301648,NM_001301647,NM_021647 MFAP3L,MFAP3L,MFAP3L,MFAP3L EXON Silent,Silent,Silent,Silent rs4692779 4 170911305 [T/C] NM_001009554,NM_001301648,NM_001301647,NM_021647 MFAP3L,MFAP3L,MFAP3L,MFAP3L EXON Silent,Silent,Silent,Silent rs4692588 4 170911443 [T/C] NM_001009554,NM_001301648,NM_001301647,NM_021647 MFAP3L,MFAP3L,MFAP3L,MFAP3L EXON Silent,Silent,Silent,Silent rs7661337 4 170912278 [A/G] NM_001009554,NM_001301648,NM_001301647,NM_021647 MFAP3L,MFAP3L,MFAP3L,MFAP3L EXON Silent,Silent,Silent,Silent rs6553484 4 170919666 [T/C] NM_001009554,NM_001301648,NM_001301647,NM_021647 MFAP3L,MFAP3L,MFAP3L,MFAP3L Silent,Silent,Silent,Silent rs6841912 4 170927723 [T/G] NM_001301647,NM_021647 MFAP3L,MFAP3L Silent,Silent rs17055385 4 170931125 [T/C] NM_001301647,NM_021647 MFAP3L,MFAP3L Silent,Silent rs6842442 4 170933203 [T/C] NM_001301647,NM_021647 MFAP3L,MFAP3L Silent,Silent rs3806826 4 170949341 [A/G] rs6821231 4 170959988 [T/C] rs2727525 4 170960062 [A/C] rs11728483 4 170972949 [T/C] rs12650424 4 170975204 [T/C] rs34202278 4 170981783 [T/G] NM_001286682,NM_182662,NM_001286683,NM_016228 AADAT,AADAT,AADAT,AADAT EXON Silent,Silent,Silent,Silent rs3796526 4 170988351 [T/C] NM_001286682,NM_182662,NM_001286683,NM_016228 AADAT,AADAT,AADAT,AADAT Silent,Silent,Silent,Silent rs2279267 4 170990053 [T/C] NM_001286682,NM_182662,NM_001286683,NM_016228 AADAT,AADAT,AADAT,AADAT Silent,Silent,Silent,Silent rs2466990 4 170993771 [A/G] NM_001286682,NM_182662,NM_001286683,NM_016228 AADAT,AADAT,AADAT,AADAT Silent,Silent,Silent,Silent rs963660 4 170995066 [T/C] NM_001286682,NM_182662,NM_001286683,NM_016228 AADAT,AADAT,AADAT,AADAT Silent,Silent,Silent,Silent rs2622068 4 170999860 [A/G] NM_001286682,NM_182662,NM_001286683,NM_016228 AADAT,AADAT,AADAT,AADAT Silent,Silent,Silent,Silent rs10213032 4 171009360 [A/G] NM_001286682,NM_182662,NM_001286683,NM_016228 AADAT,AADAT,AADAT,AADAT Silent,Silent,Silent,Silent rs2955256 4 171013833 [T/C] rs2727526 4 171017638 [A/G] rs11736939 4 171031170 [T/C] rs10000291 4 171034742 [T/C] rs1916033 4 171043706 [A/C] rs12510576 4 171044796 [A/G] rs2101065 4 171049915 [A/G] rs519847 4 171055490 [A/G] rs519160 4 171055510 [T/C] rs540256 4 171062113 [T/G] rs548846 4 171064513 [A/G] rs3846272 4 171076562 [A/G] rs1947859 4 171082172 [A/G] rs532160 4 171089568 [A/G] rs10025421 4 171090130 [A/G] rs13150580 4 171092557 [A/G] rs11132836 4 171093594 [A/G] rs11132838 4 171095168 [T/C] rs512592 4 171098146 [T/C] rs13125979 4 171101240 [T/C] rs1522605 4 171110103 [A/G] rs1949621 4 171123515 [T/C] rs1581421 4 171124116 [A/C] rs1718800 4 171127756 [T/C] rs1618361 4 171128565 [T/C] rs2687223 4 171139660 [T/C] rs7692357 4 171148608 [A/G] NR_125889 LINC01612 Silent rs1522600 4 171149711 [A/C] NR_125889 LINC01612 Silent rs1915509 4 171152392 [A/G] NR_125889 LINC01612 Silent rs17629627 4 171163418 [A/G] NR_125889 LINC01612 Silent rs1718781 4 171163569 [T/G] NR_125889 LINC01612 Silent rs10030257 4 171167671 [T/G] NR_125889 LINC01612 Silent rs10030422 4 171167789 [A/G] NR_125889 LINC01612 Silent rs12647798 4 171168272 [A/G] NR_125889 LINC01612 Silent rs10023223 4 171168353 [T/C] NR_125889 LINC01612 Silent rs12648095 4 171172831 [T/C] NR_125889 LINC01612 Silent rs9991425 4 171175255 [A/G] NR_125889 LINC01612 Silent rs17661170 4 171175320 [A/G] NR_125889 LINC01612 Silent rs10028534 4 171175522 [A/G] NR_125889 LINC01612 Silent rs10520181 4 171179337 [A/G] NR_125889 LINC01612 Silent rs4692812 4 171180273 [A/G] NR_125889 LINC01612 Silent rs7699981 4 171193885 [T/C] NR_125889 LINC01612 Silent rs17055545 4 171203364 [T/G] NR_125889 LINC01612 Silent rs17055549 4 171204193 [T/C] NR_125889 LINC01612 EXON Silent rs12647693 4 171204964 [A/G] rs12649329 4 171206696 [A/G] rs1522603 4 171207036 [T/C] rs1717072 4 171215850 [A/G] rs11132841 4 171215956 [A/G] rs17629990 4 171224046 [A/G] rs1915520 4 171227945 [T/C] rs17548053 4 171234457 [A/G] rs4692821 4 171234790 [T/C] rs6814090 4 171244684 [T/C] rs11937198 4 171263675 [T/C] rs1406514 4 171269504 [A/G] rs12506448 4 171271368 [T/C] rs6821063 4 171275890 [T/C] rs4692824 4 171288473 [A/G] rs1879500 4 171292771 [T/C] rs1919502 4 171297661 [A/G] rs1528955 4 171307124 [A/G] rs10020695 4 171307586 [T/C] rs2141473 4 171312561 [A/G] rs1919506 4 171318582 [A/C] rs7670352 4 171327181 [A/G] rs2612406 4 171339965 [T/C] rs1609380 4 171340897 [T/C] rs10520184 4 171349115 [T/C] rs1919510 4 171351306 [T/C] rs6835013 4 171351464 [A/G] rs2877520 4 171351736 [T/C] rs1528945 4 171371794 [A/C] rs1358598 4 171371979 [A/G] rs1534659 4 171386268 [T/G] rs1581676 4 171402225 [A/G] rs13134352 4 171403760 [A/G] rs2020059 4 171418411 [A/C] rs2661081 4 171420400 [A/G] rs2661079 4 171423826 [T/G] rs1848306 4 171425584 [A/C] rs7662606 4 171426045 [T/C] rs2661071 4 171448717 [T/C] rs9993427 4 171451718 [A/G] rs371100 4 171471531 [A/G] rs403730 4 171481511 [A/G] rs424540 4 171484438 [A/G] rs446973 4 171499216 [A/G] rs2055717 4 171505217 [A/G] rs413812 4 171509449 [T/C] rs406542 4 171510501 [A/G] rs368771 4 171513737 [A/C] rs396067 4 171519605 [A/G] rs13129109 4 171525130 [A/G] rs4692612 4 171537901 [T/G] rs10021531 4 171544366 [T/G] rs1596248 4 171576294 [T/C] rs10028123 4 171579204 [A/G] rs10030592 4 171590438 [T/C] rs7676680 4 171592467 [A/G] rs7665640 4 171592684 [T/C] rs7681130 4 171596102 [A/C] rs10012640 4 171603479 [T/C] rs11935380 4 171619313 [A/G] rs11936596 4 171620249 [A/G] rs11132859 4 171620514 [A/G] rs17056008 4 171628342 [T/C] rs17056017 4 171632029 [T/C] rs9312487 4 171634702 [T/C] rs7658788 4 171635106 [A/G] rs9312489 4 171637914 [A/C] rs1568621 4 171642051 [T/C] rs1533837 4 171644884 [T/G] rs1533835 4 171645207 [T/G] rs9312490 4 171651895 [A/G] rs2177183 4 171654737 [A/G] rs7697640 4 171663745 [A/G] NR_134683 LINC02382 EXON Silent rs17730512 4 171666694 [T/C] rs2332027 4 171672038 [A/G] rs11931207 4 171673765 [A/G] rs10084822 4 171680223 [T/G] rs10007705 4 171692801 [T/C] rs1589560 4 171694360 [T/C] rs4615138 4 171713039 [A/G] rs10012933 4 171722438 [A/G] rs2877558 4 171743216 [A/G] rs10001385 4 171751059 [T/C] rs1432095 4 171760509 [A/G] rs1432094 4 171762217 [T/C] rs10011172 4 171769237 [T/C] rs10520196 4 171769714 [A/G] rs10520197 4 171773560 [A/G] rs17056275 4 171775253 [A/G] rs1560566 4 171788150 [T/C] rs34572584 4 171790532 [T/G] rs1432089 4 171790788 [T/C] rs7673440 4 171807535 [A/C] rs7695819 4 171808256 [A/G] rs1432083 4 171813412 [A/G] rs17056316 4 171813485 [A/G] rs6821882 4 171821091 [T/G] rs2332074 4 171821267 [T/C] rs2082317 4 171824549 [T/C] rs6822509 4 171828587 [T/C] rs6850897 4 171842726 [A/G] rs4392476 4 171852518 [A/G] rs28666968 4 171853059 [A/G] rs11725347 4 171860973 [A/C] rs13121066 4 171872498 [A/G] rs17245674 4 171884710 [A/G] rs7674455 4 171888656 [A/G] rs7656121 4 171889916 [A/G] rs7658356 4 171890298 [T/C] rs6844809 4 171912349 [T/C] rs7682721 4 171914470 [T/G] rs13126363 4 171919389 [A/G] rs1508508 4 171936344 [T/C] rs1949007 4 171957000 [A/G] rs17056407 4 171962965 [A/G] NR_038838 LINC02431 Silent rs10006864 4 171963233 [T/C] NR_038838 LINC02431 Silent rs10022424 4 171996232 [A/G] rs4450884 4 172002025 [T/G] rs11722088 4 172006196 [T/G] rs11731647 4 172006998 [T/C] rs10032595 4 172022261 [A/C] rs13136443 4 172027644 [A/G] rs17247383 4 172031172 [A/G] rs13135657 4 172033270 [T/G] rs13137432 4 172033347 [T/C] rs7671049 4 172034838 [A/G] rs17056485 4 172036039 [A/G] rs1508511 4 172041735 [A/G] rs17056509 4 172041974 [T/C] rs17056522 4 172043988 [A/G] rs2063213 4 172050379 [A/C] rs10004389 4 172052739 [T/C] rs9997273 4 172055275 [T/C] rs11725022 4 172056196 [A/C] rs7683861 4 172072056 [T/C] rs10002593 4 172077524 [A/G] rs2055733 4 172078453 [T/C] rs7673719 4 172083089 [A/G] rs1508294 4 172089287 [T/C] rs10520201 4 172104856 [A/G] rs715990 4 172108672 [T/C] rs10033316 4 172112864 [T/C] rs6833171 4 172118449 [A/C] rs6841957 4 172124768 [T/G] rs7681110 4 172132826 [A/G] rs11132876 4 172133199 [T/C] rs6830239 4 172147796 [A/G] rs7685133 4 172155235 [T/G] rs6841319 4 172167031 [T/C] rs13145065 4 172167890 [A/G] rs1491332 4 172186360 [T/C] rs13135493 4 172199176 [T/C] rs7681428 4 172200213 [A/G] rs11132893 4 172203864 [T/G] rs12503744 4 172203928 [A/C] rs11132894 4 172227195 [T/C] rs4298103 4 172229253 [A/G] rs13135574 4 172236706 [A/G] rs1491355 4 172239480 [T/G] rs333766 4 172243508 [A/G] rs333736 4 172263476 [T/C] rs952008 4 172267887 [T/C] rs10017493 4 172269009 [A/G] rs10017580 4 172269158 [A/G] rs7664958 4 172269952 [T/G] rs2877640 4 172274229 [A/C] rs9994171 4 172275212 [T/C] rs6830090 4 172278868 [T/G] rs17056840 4 172311051 [A/G] rs12649451 4 172315768 [T/C] rs11132900 4 172328758 [T/C] rs6832175 4 172331641 [T/C] rs3913189 4 172338295 [T/G] rs17056855 4 172338748 [A/G] rs3913195 4 172347176 [A/G] rs7694458 4 172350228 [A/G] rs17056865 4 172351318 [A/G] rs13120580 4 172352348 [T/G] rs2332216 4 172354182 [T/G] rs7662060 4 172367126 [T/C] rs4692883 4 172367540 [A/C] rs4692885 4 172373388 [T/C] rs7664076 4 172388728 [A/G] rs6831239 4 172394198 [T/C] rs4144862 4 172405095 [T/G] rs10014387 4 172406840 [T/C] rs17056947 4 172416533 [A/G] rs10001552 4 172417894 [T/C] rs10032760 4 172418980 [T/C] rs1590121 4 172425609 [A/G] rs1358596 4 172432296 [A/C] rs6833332 4 172433434 [A/G] rs1569217 4 172440126 [T/C] rs6857184 4 172451166 [T/G] rs6834658 4 172460449 [A/G] rs1569214 4 172473735 [T/C] rs10213432 4 172475791 [T/C] rs10025346 4 172481191 [A/C] rs7356203 4 172485765 [A/G] rs11939052 4 172487231 [T/C] rs1919491 4 172491284 [T/C] rs13109214 4 172491592 [A/C] rs12643448 4 172492100 [A/G] rs12500769 4 172496760 [T/C] rs1406510 4 172496926 [A/G] rs10009454 4 172498522 [T/G] rs10033168 4 172499476 [T/C] rs1919495 4 172504661 [T/C] rs7654240 4 172509162 [T/C] rs10020087 4 172509887 [T/C] rs7683440 4 172516685 [A/G] rs10005145 4 172516878 [A/G] rs10032355 4 172519824 [A/G] rs17057154 4 172525210 [T/C] NR_147157 LINC02174 EXON Silent rs6833580 4 172537391 [T/C] NR_147157 LINC02174 Silent rs6847702 4 172540259 [T/C] NR_147157 LINC02174 Silent rs1406506 4 172542936 [T/C] NR_147157 LINC02174 Silent rs9991140 4 172545173 [T/C] NR_147157 LINC02174 Silent rs4692898 4 172551496 [A/C] NR_147157 LINC02174 Silent rs10015329 4 172557763 [T/G] NR_147157 LINC02174 Silent rs9312509 4 172557879 [A/G] NR_147157 LINC02174 Silent rs9312510 4 172558394 [T/G] NR_147157 LINC02174 Silent rs2172009 4 172559687 [T/C] NR_147157 LINC02174 Silent rs11929915 4 172559810 [T/C] NR_147157 LINC02174 Silent rs17057224 4 172560014 [A/C] rs12644946 4 172566190 [T/C] rs13136852 4 172568268 [A/C] rs6844440 4 172590031 [A/G] rs6553586 4 172597919 [T/C] rs1907084 4 172609720 [A/G] rs9993484 4 172633978 [T/C] rs10020928 4 172647755 [T/C] rs768709 4 172651944 [T/G] rs836028 4 172661677 [T/G] rs836022 4 172675143 [T/C] rs17057429 4 172699232 [T/C] rs10003818 4 172705236 [A/G] rs1495288 4 172713976 [T/C] rs3733432 4 172733788 [A/G] NR_134656 LOC441052 EXON Silent rs901236 4 172740734 [T/G] NM_001034845 GALNTL6 Silent rs2930907 4 172741742 [A/G] NM_001034845 GALNTL6 Silent rs494770 4 172742577 [T/C] NM_001034845 GALNTL6 Silent rs10027752 4 172747852 [A/G] NM_001034845 GALNTL6 Silent rs570686 4 172748274 [T/C] NM_001034845 GALNTL6 Silent rs580091 4 172750974 [A/G] NM_001034845 GALNTL6 Silent rs558129 4 172751111 [A/G] NM_001034845 GALNTL6 Silent rs494219 4 172758442 [A/G] NM_001034845 GALNTL6 Silent rs2046482 4 172762249 [A/G] NM_001034845 GALNTL6 Silent rs2877674 4 172763249 [A/G] NM_001034845 GALNTL6 Silent rs11132917 4 172764187 [T/G] NM_001034845 GALNTL6 Silent rs7676508 4 172776138 [T/C] NM_001034845 GALNTL6 Silent rs17057501 4 172779908 [A/G] NM_001034845 GALNTL6 Silent rs6818860 4 172786927 [A/G] NM_001034845 GALNTL6 Silent rs12503485 4 172789426 [T/C] NM_001034845 GALNTL6 Silent rs7666914 4 172790557 [A/G] NM_001034845 GALNTL6 Silent rs7683742 4 172797264 [A/C] NM_001034845 GALNTL6 Silent rs10031590 4 172797779 [A/G] NM_001034845 GALNTL6 Silent rs13101636 4 172801023 [T/C] NM_001034845 GALNTL6 Silent rs6553597 4 172808394 [A/C] NM_001034845 GALNTL6 Silent rs4124044 4 172812489 [T/G] NM_001034845 GALNTL6 Silent rs718913 4 172816200 [A/G] NM_001034845 GALNTL6 Silent rs6845054 4 172832692 [T/C] NM_001034845 GALNTL6 Silent rs6854571 4 172836939 [T/C] NM_001034845 GALNTL6 Silent rs4692643 4 172842419 [T/C] NM_001034845 GALNTL6 Silent rs7696165 4 172846645 [A/G] NM_001034845 GALNTL6 Silent rs10005702 4 172849152 [T/C] NM_001034845 GALNTL6 Silent rs11931247 4 172849554 [T/C] NM_001034845 GALNTL6 Silent rs17057585 4 172858612 [A/C] NM_001034845 GALNTL6 Silent rs332995 4 172864640 [T/C] NM_001034845 GALNTL6 Silent rs10471197 4 172868453 [T/C] NM_001034845 GALNTL6 Silent rs17057610 4 172870192 [T/G] NM_001034845 GALNTL6 Silent rs6553603 4 172870885 [A/G] NM_001034845 GALNTL6 Silent rs333003 4 172871125 [T/C] NM_001034845 GALNTL6 Silent rs405831 4 172872173 [A/G] NM_001034845 GALNTL6 Silent rs412763 4 172877646 [T/C] NM_001034845 GALNTL6 Silent rs17057743 4 172878952 [A/G] NM_001034845 GALNTL6 Silent rs332969 4 172880449 [A/G] NM_001034845 GALNTL6 Silent rs13435577 4 172886193 [A/G] NM_001034845 GALNTL6 Silent rs4692907 4 172886425 [A/G] NM_001034845 GALNTL6 Silent rs409190 4 172893271 [T/G] NM_001034845 GALNTL6 Silent rs230 4 172896473 [T/C] NM_001034845 GALNTL6 Silent rs17057803 4 172900309 [T/G] NM_001034845 GALNTL6 Silent rs184564 4 172902011 [A/G] NM_001034845 GALNTL6 Silent rs2135196 4 172920376 [T/C] NM_001034845 GALNTL6 Silent rs17057851 4 172922802 [T/C] NM_001034845 GALNTL6 Silent rs1979931 4 172929844 [A/G] NM_001034845 GALNTL6 Silent rs10030036 4 172933370 [A/G] NM_001034845 GALNTL6 Silent rs17057887 4 172943891 [A/G] NM_001034845 GALNTL6 Silent rs17057895 4 172944925 [A/G] NM_001034845 GALNTL6 Silent rs12645248 4 172945557 [T/C] NM_001034845 GALNTL6 Silent rs983560 4 172946287 [T/C] NM_001034845 GALNTL6 Silent rs13152598 4 172947230 [A/G] NM_001034845 GALNTL6 Silent rs12504133 4 172950603 [A/C] NM_001034845 GALNTL6 Silent rs6843490 4 172950660 [A/G] NM_001034845 GALNTL6 Silent rs12646854 4 172953080 [T/C] NM_001034845 GALNTL6 Silent rs17057954 4 172955489 [A/G] NM_001034845 GALNTL6 Silent rs10780085 4 172955918 [A/G] NM_001034845 GALNTL6 Silent rs4146318 4 172957015 [T/C] NM_001034845 GALNTL6 Silent rs4146317 4 172957428 [T/C] NM_001034845 GALNTL6 Silent rs17057997 4 172963750 [A/G] NM_001034845 GALNTL6 Silent rs13134541 4 172965481 [T/C] NM_001034845 GALNTL6 Silent rs7654286 4 172968055 [T/C] NM_001034845 GALNTL6 Silent rs1394860 4 172979002 [A/G] NM_001034845 GALNTL6 Silent rs1394859 4 172985760 [T/C] NM_001034845 GALNTL6 Silent rs13139421 4 172997356 [T/C] NM_001034845 GALNTL6 Silent rs2877689 4 172999916 [A/G] NM_001034845 GALNTL6 Silent rs13136240 4 173001831 [T/C] NM_001034845 GALNTL6 Silent rs17058017 4 173005057 [A/G] NM_001034845 GALNTL6 Silent rs9990764 4 173005461 [A/G] NM_001034845 GALNTL6 Silent rs17058022 4 173005491 [T/C] NM_001034845 GALNTL6 Silent rs6829575 4 173010013 [A/G] NM_001034845 GALNTL6 Silent rs1354631 4 173013636 [A/G] NM_001034845 GALNTL6 Silent rs2131002 4 173015421 [A/G] NM_001034845 GALNTL6 Silent rs17058055 4 173020016 [A/G] NM_001034845 GALNTL6 Silent rs6846244 4 173024088 [T/C] NM_001034845 GALNTL6 Silent rs17219104 4 173025475 [A/G] NM_001034845 GALNTL6 Silent rs13146120 4 173034436 [A/G] NM_001034845 GALNTL6 Silent rs2201113 4 173035260 [A/C] NM_001034845 GALNTL6 Silent rs17219493 4 173040504 [A/G] NM_001034845 GALNTL6 Silent rs10016776 4 173047549 [T/C] NM_001034845 GALNTL6 Silent rs6553608 4 173052098 [A/C] NM_001034845 GALNTL6 Silent rs6553610 4 173068658 [T/C] NM_001034845 GALNTL6 Silent rs13110849 4 173084108 [A/G] NM_001034845 GALNTL6 Silent rs13124593 4 173089205 [A/G] NM_001034845 GALNTL6 Silent rs12644997 4 173095500 [T/C] NM_001034845 GALNTL6 Silent rs2202281 4 173109636 [A/G] NM_001034845 GALNTL6 Silent rs1960679 4 173115128 [A/G] NM_001034845 GALNTL6 Silent rs6825169 4 173125742 [A/G] NM_001034845 GALNTL6 Silent rs836306 4 173129218 [T/C] NM_001034845 GALNTL6 Silent rs13122326 4 173135051 [T/G] NM_001034845 GALNTL6 Silent rs2654790 4 173142530 [A/G] NM_001034845 GALNTL6 Silent rs9997484 4 173142594 [A/G] NM_001034845 GALNTL6 Silent rs836325 4 173152095 [A/G] NM_001034845 GALNTL6 Silent rs10012505 4 173152405 [T/C] NM_001034845 GALNTL6 Silent rs836321 4 173164661 [A/G] NM_001034845 GALNTL6 Silent rs836322 4 173167398 [A/G] NM_001034845 GALNTL6 Silent rs10049623 4 173172113 [T/C] NM_001034845 GALNTL6 Silent rs1354356 4 173175173 [T/C] NM_001034845 GALNTL6 Silent rs6843010 4 173175931 [T/C] NM_001034845 GALNTL6 Silent rs905571 4 173177403 [A/G] NM_001034845 GALNTL6 Silent rs10002142 4 173178085 [A/C] NM_001034845 GALNTL6 Silent rs12505892 4 173179915 [T/G] NM_001034845 GALNTL6 Silent rs10021776 4 173185572 [A/G] NM_001034845 GALNTL6 Silent rs9991827 4 173206315 [A/G] NM_001034845 GALNTL6 Silent rs9312523 4 173208191 [A/G] NM_001034845 GALNTL6 Silent rs1955282 4 173213263 [T/C] NM_001034845 GALNTL6 Silent rs6839113 4 173215669 [T/G] NM_001034845 GALNTL6 Silent rs9997921 4 173216873 [T/C] NM_001034845 GALNTL6 Silent rs2654774 4 173227094 [T/G] NM_001034845 GALNTL6 Silent rs17289279 4 173227165 [T/C] NM_001034845 GALNTL6 Silent rs2054684 4 173238445 [A/G] NM_001034845 GALNTL6 Silent rs333387 4 173244399 [T/C] NM_001034845 GALNTL6 Silent rs4692917 4 173271397 [A/G] NM_001034845 GALNTL6 Silent rs988129 4 173285963 [T/C] NM_001034845 GALNTL6 Silent rs1484019 4 173287422 [T/C] NM_001034845 GALNTL6 Silent rs17058337 4 173287704 [A/G] NM_001034845 GALNTL6 Silent rs1508257 4 173302198 [T/C] NM_001034845 GALNTL6 Silent rs335998 4 173323928 [T/C] NM_001034845 GALNTL6 Silent rs17058391 4 173324694 [A/G] NM_001034845 GALNTL6 Silent rs1508260 4 173324955 [T/G] NM_001034845 GALNTL6 Silent rs6852501 4 173331787 [A/C] NM_001034845 GALNTL6 Silent rs335983 4 173333056 [A/G] NM_001034845 GALNTL6 Silent rs663643 4 173340994 [T/C] NM_001034845 GALNTL6 Silent rs335972 4 173353213 [A/G] NM_001034845 GALNTL6 Silent rs10024431 4 173354354 [T/G] NM_001034845 GALNTL6 Silent rs163185 4 173356104 [T/C] NM_001034845 GALNTL6 Silent rs336003 4 173358095 [T/G] NM_001034845 GALNTL6 Silent rs12644293 4 173360981 [T/C] NM_001034845 GALNTL6 Silent rs338021 4 173399986 [A/C] NM_001034845 GALNTL6 Silent rs13142236 4 173404269 [T/C] NM_001034845 GALNTL6 Silent rs10019934 4 173405278 [T/C] NM_001034845 GALNTL6 Silent rs12108601 4 173409234 [A/G] NM_001034845 GALNTL6 Silent rs6553634 4 173418304 [A/G] NM_001034845 GALNTL6 Silent rs1551446 4 173423366 [A/G] NM_001034845 GALNTL6 Silent rs2124204 4 173424803 [T/G] NM_001034845 GALNTL6 Silent rs338055 4 173438438 [A/G] NM_001034845 GALNTL6 Silent rs17233636 4 173440948 [A/G] NM_001034845 GALNTL6 Silent rs13130915 4 173466872 [T/C] NM_001034845 GALNTL6 Silent rs6819214 4 173476675 [A/C] NM_001034845 GALNTL6 Silent rs2332519 4 173478710 [A/G] NM_001034845 GALNTL6 Silent rs13102637 4 173491064 [A/C] NM_001034845 GALNTL6 Silent rs17234582 4 173495158 [T/C] NM_001034845 GALNTL6 Silent rs10434280 4 173513908 [A/G] NM_001034845 GALNTL6 Silent rs6858309 4 173521239 [A/G] NM_001034845 GALNTL6 Silent rs1455129 4 173535503 [A/G] NM_001034845 GALNTL6 Silent rs1551447 4 173541374 [T/C] NM_001034845 GALNTL6 Silent rs2332544 4 173543874 [A/G] NM_001034845 GALNTL6 Silent rs4695771 4 173562564 [A/G] NM_001034845,NR_125895,NR_125894 GALNTL6,LOC101928314,LOC101928314 Silent,Silent,Silent rs837198 4 173585910 [A/G] NM_001034845,NR_125895,NR_125894 GALNTL6,LOC101928314,LOC101928314 Silent,Silent,Silent rs1437842 4 173597016 [A/G] NM_001034845,NR_125895,NR_125894 GALNTL6,LOC101928314,LOC101928314 Silent,Silent,Silent rs10520242 4 173598033 [T/C] NM_001034845,NR_125895,NR_125894 GALNTL6,LOC101928314,LOC101928314 Silent,Silent,Silent rs17058736 4 173598461 [A/C] NM_001034845,NR_125895,NR_125894 GALNTL6,LOC101928314,LOC101928314 Silent,Silent,Silent rs6848466 4 173614720 [A/G] NM_001034845,NR_125894 GALNTL6,LOC101928314 Silent,Silent rs6813194 4 173625960 [A/G] NM_001034845,NR_125894 GALNTL6,LOC101928314 Silent,Silent rs1946797 4 173632325 [T/C] NM_001034845,NR_125894 GALNTL6,LOC101928314 Silent,Silent rs9312527 4 173637709 [A/G] NM_001034845,NR_125894 GALNTL6,LOC101928314 Silent,Silent rs17058802 4 173643640 [A/C] NM_001034845,NR_125894 GALNTL6,LOC101928314 Silent,Silent rs11132959 4 173646842 [A/G] NM_001034845,NR_125894 GALNTL6,LOC101928314 Silent,Silent rs1437845 4 173653680 [A/G] NM_001034845 GALNTL6 Silent rs2083136 4 173663511 [A/C] NM_001034845 GALNTL6 Silent rs716647 4 173664444 [T/C] NM_001034845 GALNTL6 Silent rs12498866 4 173677193 [A/G] NM_001034845 GALNTL6 Silent rs12642442 4 173684873 [T/G] NM_001034845 GALNTL6 Silent rs12511715 4 173686773 [T/C] NM_001034845 GALNTL6 Silent rs2332553 4 173689414 [A/G] NM_001034845 GALNTL6 Silent rs9997085 4 173693980 [A/G] NM_001034845 GALNTL6 Silent rs10019400 4 173720434 [A/G] NM_001034845 GALNTL6 Silent rs750376 4 173731762 [A/C] NM_001034845 GALNTL6 Silent rs1459157 4 173739244 [T/C] NM_001034845 GALNTL6 Silent rs9884518 4 173739355 [A/G] NM_001034845 GALNTL6 Silent rs1551664 4 173742700 [T/C] NM_001034845 GALNTL6 Silent rs10033472 4 173753757 [T/C] NM_001034845 GALNTL6 Silent rs17058946 4 173757115 [A/G] NM_001034845 GALNTL6 Silent rs10001933 4 173758268 [T/C] NM_001034845 GALNTL6 Silent rs11930252 4 173760646 [A/G] NM_001034845 GALNTL6 Silent rs1824347 4 173764577 [T/C] NM_001034845 GALNTL6 Silent rs17058964 4 173770121 [A/G] NM_001034845 GALNTL6 Silent rs6823952 4 173770940 [T/C] NM_001034845 GALNTL6 Silent rs6833917 4 173777083 [A/G] NM_001034845 GALNTL6 Silent rs6818634 4 173786855 [T/C] NM_001034845 GALNTL6 Silent rs7660673 4 173797032 [T/C] NM_001034845 GALNTL6 Silent rs12512152 4 173797669 [T/C] NM_001034845 GALNTL6 Silent rs1903126 4 173797856 [T/C] NM_001034845 GALNTL6 Silent rs6810619 4 173803914 [T/C] NM_001034845 GALNTL6 Silent rs1993616 4 173820365 [A/G] NM_001034845 GALNTL6 Silent rs2653824 4 173822571 [T/C] NM_001034845 GALNTL6 Silent rs10029692 4 173829168 [A/G] NM_001034845 GALNTL6 Silent rs2610200 4 173832582 [T/C] NM_001034845 GALNTL6 Silent rs2653831 4 173849497 [A/G] NM_001034845 GALNTL6 Silent rs17254079 4 173868291 [T/C] NM_001034845 GALNTL6 Silent rs13150573 4 173872313 [T/C] NM_001034845 GALNTL6 Silent rs2653841 4 173872401 [A/G] NM_001034845 GALNTL6 Silent rs17254336 4 173874976 [T/G] NM_001034845 GALNTL6 Silent rs4696036 4 173885229 [T/G] NM_001034845 GALNTL6 Silent rs10520251 4 173889191 [A/G] NM_001034845 GALNTL6 Silent rs6811225 4 173914254 [T/C] NM_001034845 GALNTL6 Silent rs4574383 4 173916231 [A/G] NM_001034845 GALNTL6 Silent rs4572852 4 173920304 [T/G] NM_001034845 GALNTL6 Silent rs17059082 4 173930848 [A/C] NM_001034845 GALNTL6 Silent rs6832095 4 173935056 [T/G] NM_001034845 GALNTL6 Silent rs7659038 4 173944939 [A/G] NM_001034845 GALNTL6 Silent rs10020676 4 173945730 [A/G] NM_001034845 GALNTL6 Silent rs4331761 4 173949124 [A/G] NM_001034845 GALNTL6 Silent rs10005134 4 173949815 [T/C] NM_001034845 GALNTL6 Silent rs2019683 4 173962425 [A/G] rs11132977 4 173963006 [T/C] rs6817670 4 173966463 [A/G] rs4533747 4 173980053 [T/G] rs4309818 4 173991635 [T/C] rs7667977 4 173995332 [A/C] rs4293766 4 173995383 [A/G] rs11725123 4 173996293 [A/G] rs10018524 4 174007048 [A/G] rs4048413 4 174016641 [T/C] rs11935600 4 174020403 [T/C] rs7663778 4 174029121 [T/C] rs6856402 4 174035061 [A/G] rs3966013 4 174046343 [A/G] rs13138296 4 174048218 [T/C] rs10520253 4 174050460 [T/C] rs3864173 4 174052829 [T/C] rs4356895 4 174053361 [A/C] NR_134242 LOC101930370 EXON Silent rs3966014 4 174057435 [T/C] NR_134242 LOC101930370 Silent rs6829566 4 174061455 [A/G] NR_134242 LOC101930370 Silent rs716357 4 174062064 [A/G] NR_134242 LOC101930370 Silent rs4639046 4 174062281 [A/C] NR_134242 LOC101930370 Silent rs6822683 4 174063974 [A/G] NR_134242 LOC101930370 Silent rs6553679 4 174072292 [T/C] NR_134242,NR_134241 LOC101930370,LOC101930370 Silent,Silent rs7689781 4 174072755 [A/G] NR_134242,NR_134241 LOC101930370,LOC101930370 Silent,Silent rs11734882 4 174075363 [A/G] NR_134242,NR_134241 LOC101930370,LOC101930370 Silent,Silent rs7669267 4 174081834 [T/C] NR_134242,NR_134241 LOC101930370,LOC101930370 Silent,Silent rs4419455 4 174083622 [A/G] NR_134242,NR_134241 LOC101930370,LOC101930370 Silent,Silent rs1054496 4 174089080 [T/C] NR_134242,NR_134241 LOC101930370,LOC101930370 Silent,Silent rs1006003 4 174092791 [A/G] NM_017423 GALNT7 Silent rs722827 4 174098017 [T/C] NM_017423 GALNT7 Silent rs11942280 4 174101050 [T/C] NM_017423 GALNT7 Silent rs13151627 4 174107537 [T/C] NM_017423 GALNT7 Silent rs11732929 4 174119049 [T/G] NM_017423 GALNT7 Silent rs4535319 4 174127031 [A/G] NM_017423 GALNT7 Silent rs10213525 4 174129740 [A/G] NM_017423 GALNT7 Silent rs11737748 4 174130503 [T/C] NM_017423 GALNT7 Silent rs10001613 4 174132146 [A/G] NM_017423 GALNT7 Silent rs7670064 4 174134684 [A/G] NM_017423 GALNT7 Silent rs9995556 4 174136952 [T/C] NM_017423 GALNT7 Silent rs4608791 4 174146299 [A/C] NM_017423 GALNT7 Silent rs4696054 4 174156383 [A/C] NM_017423 GALNT7 Silent rs12639929 4 174156538 [A/G] NM_017423 GALNT7 Silent rs7672108 4 174165126 [T/C] NM_017423 GALNT7 Silent rs6839839 4 174179493 [T/C] NM_017423 GALNT7 Silent rs10471199 4 174186322 [A/G] NM_017423 GALNT7 Silent rs13128039 4 174190222 [A/G] NM_017423 GALNT7 Silent rs6816923 4 174199490 [A/G] NM_017423 GALNT7 Silent rs6825703 4 174210358 [T/C] NM_017423 GALNT7 Silent rs3775591 4 174222981 [A/G] NM_017423 GALNT7 Silent rs7665469 4 174229762 [T/C] NM_017423 GALNT7 Silent rs6842693 4 174232666 [T/C] NM_017423 GALNT7 Silent rs7658148 4 174235624 [T/C] NM_017423 GALNT7 Silent rs3775590 4 174243631 [T/C] NM_017423 GALNT7 EXON Silent rs6856630 4 174250383 [T/G] rs11731262 4 174251422 [A/G] rs11939608 4 174253938 [T/C] NM_001130688,NM_002129,NM_001130689 HMGB2,HMGB2,HMGB2 Silent,Silent,Silent rs13105666 4 174261713 [T/G] rs12498911 4 174262102 [T/C] rs4696060 4 174271800 [T/C] rs4696062 4 174273997 [A/G] rs13133723 4 174290830 [A/C] rs965931 4 174297683 [A/G] NM_003864 SAP30 Silent rs12498508 4 174301717 [T/C] rs2101092 4 174315913 [A/G] NM_001329597,NM_007281 SCRG1,SCRG1 Silent,Silent rs7680254 4 174320595 [A/C] NM_001329597 SCRG1 Silent rs13148735 4 174323228 [T/C] NM_001329597 SCRG1 Silent rs4695834 4 174325544 [A/C] NM_001329597 SCRG1 Silent rs7655786 4 174327618 [T/C] NM_001329597 SCRG1 Silent rs10002252 4 174332615 [A/G] NM_001329597 SCRG1 Silent rs13147839 4 174344177 [A/G] NM_001329597 SCRG1 Silent rs2086477 4 174347475 [A/C] NM_001329597 SCRG1 Silent rs1481121 4 174348397 [T/C] NM_001329597 SCRG1 Silent rs35033382 4 174353610 [T/C] NM_001329597 SCRG1 Silent rs1372527 4 174364387 [T/C] NM_001329597 SCRG1 Silent rs1946968 4 174366240 [A/C] NM_001329597 SCRG1 Silent rs17059455 4 174369546 [T/C] NM_001329597 SCRG1 Silent rs1561792 4 174369908 [T/C] NM_001329597 SCRG1 Silent rs17059458 4 174371557 [A/G] NM_001329597 SCRG1 Silent rs7659018 4 174376198 [T/C] NM_001329597 SCRG1 Silent rs6419984 4 174392507 [T/C] NM_001329597 SCRG1 Silent rs10520259 4 174398324 [T/C] NM_001329597 SCRG1 Silent rs7654591 4 174398621 [T/C] NM_001329597 SCRG1 Silent rs4496557 4 174401970 [T/C] NM_001329597 SCRG1 Silent rs13141534 4 174425236 [T/C] NM_001329597 SCRG1 Silent rs1020231 4 174426144 [A/G] NM_001329597 SCRG1 Silent rs7661281 4 174437070 [T/G] NM_001329597 SCRG1 Silent rs6820150 4 174438227 [A/C] NM_001329597 SCRG1 Silent rs7655560 4 174438897 [A/G] NM_001329597 SCRG1 Silent rs12644553 4 174442919 [T/G] rs17059527 4 174443496 [T/C] rs17059534 4 174444902 [A/G] rs10520260 4 174447349 [A/G] rs13141356 4 174447362 [A/C] rs13146346 4 174453337 [T/C] NR_136197,NR_136193,NR_136192,NR_136194,NR_136196,NR_136200,NR_136198,NR_136201,NR_136195,NR_136199,NR_003679 HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6813810 4 174454083 [T/C] NR_136197,NR_136193,NR_136192,NR_136194,NR_136196,NR_136200,NR_136198,NR_136201,NR_136195,NR_136199,NR_003679 HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17059563 4 174455265 [T/C] NR_136197,NR_136193,NR_136192,NR_136194,NR_136196,NR_136200,NR_136198,NR_136201,NR_136195,NR_136199,NR_003679 HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2332691 4 174455297 [T/C] NR_136197,NR_136193,NR_136192,NR_136194,NR_136196,NR_136200,NR_136198,NR_136201,NR_136195,NR_136199,NR_003679 HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2877766 4 174455685 [T/G] NR_136197,NR_136193,NR_136192,NR_136194,NR_136196,NR_136200,NR_136198,NR_136201,NR_136195,NR_136199,NR_003679 HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13114604 4 174456068 [A/G] NR_136197,NR_136193,NR_136192,NR_136194,NR_136196,NR_136200,NR_136198,NR_136201,NR_136195,NR_136199,NR_003679 HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4695845 4 174456843 [T/C] NR_136197,NR_136193,NR_136192,NR_136194,NR_136196,NR_136200,NR_136198,NR_136201,NR_136195,NR_136199,NR_003679 HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13131421 4 174458901 [T/C] NR_136197,NR_136193,NR_136192,NR_136194,NR_136196,NR_136200,NR_136198,NR_136201,NR_136195,NR_136199,NR_003679 HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs744724 4 174459823 [T/C] NR_136197,NR_136193,NR_136192,NR_136194,NR_136196,NR_136200,NR_136198,NR_136201,NR_136195,NR_136199,NR_003679 HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6820651 4 174461343 [A/G] NR_136197,NR_136193,NR_136192,NR_136194,NR_136196,NR_136200,NR_136198,NR_136201,NR_136195,NR_136199,NR_003679 HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1,HAND2-AS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4695849 4 174471671 [A/G] NR_136196,NR_136195 HAND2-AS1,HAND2-AS1 Silent,Silent rs11132992 4 174476098 [A/G] NR_136196,NR_136195 HAND2-AS1,HAND2-AS1 Silent,Silent rs4695853 4 174484121 [T/C] NR_136196,NR_136195 HAND2-AS1,HAND2-AS1 Silent,Silent rs4490433 4 174497836 [A/G] NR_136196,NR_136195 HAND2-AS1,HAND2-AS1 Silent,Silent rs4695857 4 174502457 [A/C] NR_136196,NR_136195 HAND2-AS1,HAND2-AS1 Silent,Silent rs7681766 4 174507822 [A/G] NR_136196 HAND2-AS1 Silent rs17328110 4 174509660 [A/G] NR_136196 HAND2-AS1 Silent rs4160 4 174509911 [A/G] NR_136196 HAND2-AS1 Silent rs13136539 4 174513213 [A/G] rs12646107 4 174515682 [A/C] rs11132998 4 174516590 [T/C] rs7683900 4 174518512 [A/G] rs11724478 4 174519735 [T/C] rs4639045 4 174521315 [T/C] rs13110724 4 174530500 [T/C] rs11945239 4 174530652 [A/G] rs11731252 4 174530927 [T/C] rs13143445 4 174540510 [A/G] rs13103021 4 174544577 [T/C] rs13111144 4 174555529 [A/G] rs4359880 4 174562083 [A/G] rs4282145 4 174565021 [T/G] rs11725485 4 174571498 [A/G] rs17263178 4 174573033 [A/G] rs11723222 4 174578566 [A/C] rs11728325 4 174578616 [T/C] rs17263395 4 174579326 [T/C] rs12647892 4 174580179 [T/G] rs4645197 4 174586096 [T/C] rs6841699 4 174591579 [T/C] rs10018807 4 174596609 [A/G] rs17059684 4 174598134 [T/C] rs4615152 4 174599459 [T/C] rs11727767 4 174602048 [A/G] rs17263985 4 174603650 [T/C] rs7698692 4 174604104 [A/G] rs17264076 4 174605859 [T/G] rs13142579 4 174605978 [A/G] rs12649191 4 174606591 [T/C] rs6813832 4 174609530 [T/C] rs13132889 4 174609693 [T/G] rs9312547 4 174620399 [T/C] rs12499670 4 174621493 [T/C] rs4695873 4 174623476 [T/G] rs4317181 4 174628319 [T/C] rs11133012 4 174630567 [A/G] rs4401434 4 174631643 [A/G] rs4434222 4 174631819 [A/G] rs4631014 4 174632969 [A/G] rs4364235 4 174635674 [T/C] rs6816095 4 174642677 [T/G] rs6553719 4 174643499 [T/G] rs28436719 4 174643709 [A/G] rs4521323 4 174655914 [A/C] rs7692617 4 174657554 [A/G] rs7694565 4 174657851 [A/C] rs17264373 4 174659094 [A/G] rs10520263 4 174659937 [A/C] rs17059783 4 174665992 [T/G] rs6830691 4 174667332 [T/C] rs6813034 4 174670065 [A/G] rs13108803 4 174679198 [A/G] rs11929802 4 174684932 [T/C] rs4695885 4 174686346 [A/G] rs6553727 4 174686458 [A/G] rs12506204 4 174701186 [A/G] rs3922692 4 174713351 [A/G] rs4695886 4 174723835 [T/C] rs7689307 4 174729270 [A/G] rs7683033 4 174731952 [T/G] rs4615153 4 174741938 [A/G] rs6833126 4 174751009 [T/C] rs4544692 4 174760546 [A/G] rs6813541 4 174772568 [T/G] rs7700171 4 174777061 [A/G] rs13138013 4 174777578 [T/C] rs6553733 4 174794014 [A/G] rs6827215 4 174800374 [T/C] rs4600896 4 174802918 [A/G] rs9997597 4 174803040 [A/C] rs10471202 4 174803471 [T/G] rs12649679 4 174810894 [A/G] rs4358372 4 174817063 [T/C] rs4695894 4 174817710 [A/G] rs4333160 4 174819012 [A/G] NR_146487 LINC02269 Silent rs4398502 4 174819200 [A/G] NR_146487 LINC02269 Silent rs4615154 4 174819487 [T/C] NR_146487 LINC02269 Silent rs6824200 4 174820018 [T/C] NR_146487 LINC02269 Silent rs7657936 4 174822905 [A/C] NR_146487 LINC02269 Silent rs10033133 4 174824576 [T/C] NR_146487 LINC02269 Silent rs4330337 4 174826120 [T/C] NR_146487 LINC02269 Silent rs3887907 4 174826157 [T/G] NR_146487 LINC02269 Silent rs7700127 4 174831241 [A/G] NR_146487 LINC02269 Silent rs4695895 4 174837887 [T/C] NR_146487 LINC02269 Silent rs15884 4 174850559 [T/C] NR_146487 LINC02269 EXON Silent rs13107942 4 174852035 [T/G] rs9999393 4 174853695 [T/C] rs7670348 4 174854581 [T/C] rs4554043 4 174854827 [A/G] rs12500903 4 174858993 [T/C] rs3889926 4 174859997 [T/C] rs6858266 4 174868363 [A/G] rs7657182 4 174873969 [A/G] rs7682848 4 174877383 [T/C] rs4547776 4 174879877 [A/G] rs6845317 4 174894345 [A/G] rs11934296 4 174900688 [A/G] rs7659538 4 174906286 [A/G] rs13119610 4 174908521 [T/C] rs6848831 4 174908578 [T/C] rs4495020 4 174920657 [A/G] rs4235203 4 174928071 [T/C] rs6823093 4 174937446 [A/G] rs13144752 4 174945087 [T/C] rs6812370 4 174947684 [A/G] rs10520267 4 174956412 [T/C] rs11133026 4 174961164 [T/C] rs4695759 4 174963224 [A/G] rs17060079 4 174964203 [T/C] rs13128730 4 174965215 [A/G] rs1540448 4 174966483 [T/C] rs10020606 4 174969224 [A/G] rs9996330 4 174984230 [A/G] rs7670262 4 174987671 [T/C] rs6553765 4 174991468 [T/C] rs2196368 4 174996402 [A/C] rs13118468 4 175000272 [A/G] rs2217849 4 175002024 [A/C] rs2332756 4 175002057 [A/G] rs877019 4 175006016 [T/G] rs4695907 4 175008790 [A/G] rs17052141 4 175009870 [T/C] rs11133030 4 175017835 [A/G] NR_125896 LINC02268 Silent rs6834670 4 175022693 [A/C] NR_125896 LINC02268 Silent rs11946672 4 175025442 [T/C] NR_125896 LINC02268 Silent rs2196387 4 175031632 [T/C] NR_125896 LINC02268 Silent rs1992021 4 175033659 [A/G] NR_125896 LINC02268 Silent rs10015990 4 175035169 [T/G] NR_125896 LINC02268 Silent rs6845584 4 175036522 [A/G] NR_125896 LINC02268 Silent rs2332758 4 175039764 [T/C] NR_125896 LINC02268 Silent rs6838064 4 175041257 [A/C] NR_125896 LINC02268 Silent rs6838591 4 175045002 [A/G] NR_125896 LINC02268 Silent rs10520270 4 175046985 [A/G] NR_125896 LINC02268 Silent rs10002205 4 175053051 [A/G] NR_125896 LINC02268 Silent rs17060221 4 175057033 [A/C] NR_125896 LINC02268 Silent rs2196381 4 175057725 [T/G] NR_125896 LINC02268 Silent rs4695912 4 175059383 [A/C] NR_125896 LINC02268 Silent rs6827803 4 175060620 [T/C] NR_125896 LINC02268 Silent rs17334566 4 175061541 [A/C] NR_125896 LINC02268 Silent rs1992017 4 175062207 [A/G] NR_125896 LINC02268 Silent rs7662489 4 175063224 [A/G] NR_125896 LINC02268 Silent rs1992016 4 175063668 [T/G] NR_125896 LINC02268 Silent rs17060286 4 175065347 [A/G] NR_125896 LINC02268 Silent rs2196380 4 175065821 [A/G] NR_125896 LINC02268 Silent rs4342175 4 175066056 [T/G] NR_125896 LINC02268 Silent rs10520272 4 175066104 [A/G] NR_125896 LINC02268 Silent rs6851647 4 175067059 [T/C] NR_125896 LINC02268 Silent rs2217855 4 175067665 [A/C] NR_125896 LINC02268 Silent rs10520273 4 175067806 [T/C] NR_125896 LINC02268 Silent rs749493 4 175068695 [A/G] NR_125896 LINC02268 Silent rs1865656 4 175068856 [T/C] NR_125896 LINC02268 Silent rs873372 4 175069861 [A/G] NR_125896 LINC02268 Silent rs6836227 4 175070243 [T/C] NR_125896 LINC02268 Silent rs4695772 4 175074766 [A/G] NR_125896 LINC02268 Silent rs11733331 4 175076940 [T/C] NR_125896 LINC02268 Silent rs11734349 4 175077652 [T/C] NR_125896 LINC02268 Silent rs17276390 4 175080533 [A/G] NR_125896 LINC02268 Silent rs2196379 4 175084416 [A/C] NR_125896 LINC02268 Silent rs10003923 4 175086079 [T/C] NR_125896 LINC02268 Silent rs4695913 4 175086260 [A/C] NR_125896 LINC02268 Silent rs2164380 4 175089750 [A/G] NR_125896 LINC02268 Silent rs7657652 4 175094250 [T/G] NR_125896 LINC02268 Silent rs7677750 4 175097435 [A/G] NR_125896 LINC02268 Silent rs7661496 4 175097637 [A/G] NR_125896 LINC02268 Silent rs6828239 4 175103590 [T/C] NR_125896 LINC02268 Silent rs6553774 4 175105239 [A/G] NR_125896 LINC02268 Silent rs11942884 4 175112520 [T/G] NR_125896 LINC02268 Silent rs17060350 4 175113110 [A/G] NR_125896 LINC02268 Silent rs1467003 4 175114675 [A/G] NR_125896 LINC02268 Silent rs1467005 4 175115254 [T/C] NR_125896 LINC02268 Silent rs2174904 4 175120513 [A/G] NR_125896 LINC02268 Silent rs12651020 4 175121923 [A/G] NR_125896 LINC02268 Silent rs11947112 4 175122454 [A/G] NR_125896 LINC02268 Silent rs4235204 4 175125617 [T/C] NR_125896 LINC02268 Silent rs12651414 4 175126378 [A/C] NR_125896 LINC02268 Silent rs10520274 4 175130244 [G/C] NR_125896 LINC02268 Silent rs1032988 4 175133901 [A/G] NR_125896 LINC02268 Silent rs4695914 4 175135244 [T/C] NR_125896 LINC02268 Silent rs970096 4 175135624 [A/G] NR_125896 LINC02268 Silent rs17060393 4 175135901 [T/C] NR_125896 LINC02268 Silent rs954926 4 175139380 [A/G] NR_125896 LINC02268 Silent rs13150997 4 175143493 [T/C] rs9991589 4 175149943 [A/G] rs11736418 4 175150481 [T/G] rs17357120 4 175157743 [A/G] rs14278 4 175158412 [T/C] NM_012180 FBXO8 EXON Silent rs7664501 4 175162767 [T/C] NM_012180 FBXO8 Silent rs17060428 4 175167253 [A/G] NM_012180 FBXO8 Silent rs6824643 4 175168083 [A/G] NM_012180 FBXO8 Silent rs6851312 4 175168153 [A/G] NM_012180 FBXO8 Silent rs13109634 4 175170526 [T/C] NM_012180 FBXO8 Silent rs10520276 4 175183493 [T/C] NM_012180 FBXO8 Silent rs17060434 4 175184671 [A/G] NM_012180 FBXO8 Silent rs11730346 4 175202610 [A/G] NM_012180 FBXO8 Silent rs7685970 4 175203977 [A/G] NM_012180 FBXO8 Silent rs11555602 4 175204676 [A/G] NM_012180 FBXO8 EXON Silent rs13101580 4 175219813 [A/G] NM_001040157,NM_001145314 CEP44,CEP44 Silent,Silent rs4695918 4 175225452 [A/G] NM_001040157,NM_001145314 CEP44,CEP44 EXON Missense_G147S,Missense_G147S rs17060455 4 175230896 [A/G] NM_001040157,NM_001145314 CEP44,CEP44 Silent,Silent rs4695920 4 175234130 [A/G] NM_001040157,NM_001145314 CEP44,CEP44 Silent,Silent rs1553669 4 175237408 [T/C] NM_001040157,NM_001145314 CEP44,CEP44 EXON Synonymous_T351T,Synonymous_T351T rs17358230 4 175238508 [T/C] NM_001040157,NM_001145314 CEP44,CEP44 EXON Synonymous_L383L,Silent rs4610314 4 175240518 [T/C] NM_001040157,NM_001145314 CEP44,CEP44 EXON Silent,Silent rs1001914 4 175245146 [A/C] NM_001145314 CEP44 Silent rs6553781 4 175246203 [A/G] NM_001145314 CEP44 Silent rs17060468 4 175249433 [A/G] NM_001145314 CEP44 Silent rs11934405 4 175270804 [T/C] rs4695924 4 175273562 [A/G] rs4467538 4 175282806 [A/C] rs6553785 4 175300338 [T/C] rs4518223 4 175340298 [T/C] rs4499680 4 175345619 [T/G] rs4484269 4 175347444 [T/C] rs7664475 4 175351787 [A/G] rs7669690 4 175351902 [T/C] rs6833543 4 175352929 [T/C] rs13135838 4 175354852 [A/G] rs12498292 4 175358647 [A/G] rs1035804 4 175372799 [T/C] rs12649767 4 175375824 [A/G] rs2555622 4 175376440 [A/C] rs2612666 4 175379210 [T/C] rs1426936 4 175384927 [A/G] rs3846297 4 175388125 [T/C] rs6827776 4 175389785 [A/G] rs1426946 4 175390534 [A/G] rs4613543 4 175403673 [A/G] rs9312555 4 175411953 [A/G] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD EXON Silent,Silent,Silent,Silent,Silent,Silent rs8752 4 175412477 [T/C] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD EXON Silent,Silent,Silent,Silent,Silent,Silent rs2253270 4 175412689 [A/C] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD EXON Silent,Silent,Silent,Silent,Silent,Silent rs13106936 4 175415991 [A/G] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent rs3857075 4 175416331 [A/C] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent rs3101254 4 175421255 [A/G] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent rs6835385 4 175421266 [A/G] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent rs11133041 4 175421464 [A/G] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent rs2612656 4 175422289 [A/G] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent rs7349744 4 175424172 [A/G] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent rs7673685 4 175428732 [A/C] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent rs3775977 4 175429808 [A/G] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860,NM_001363574 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2612659 4 175433338 [A/C] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860,NM_001363574 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17294646 4 175433709 [T/C] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860,NM_001363574 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11722919 4 175434074 [T/C] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860,NM_001363574 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2555632 4 175434162 [T/C] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860,NM_001363574 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3797012 4 175434520 [A/C] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860,NM_001363574 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2612660 4 175434849 [A/G] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860,NM_001363574 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2081654 4 175437117 [A/G] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860,NM_001363574 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2555645 4 175437621 [A/C] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860,NM_001363574 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD,HPGD Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1050145 4 175443156 [T/C] NM_001256305,NM_001256307,NM_001145816,NM_001256306,NM_001256301,NM_000860,NM_001363574 HPGD,HPGD,HPGD,HPGD,HPGD,HPGD,HPGD EXON Synonymous_Q52Q,Silent,Synonymous_Q52Q,Synonymous_Q52Q,Silent,Synonymous_Q52Q,Synonymous_Q52Q rs1426945 4 175444382 [T/C] rs17361009 4 175454164 [T/G] rs12645863 4 175457629 [A/G] rs2251316 4 175458289 [A/C] rs7657391 4 175460403 [T/C] rs17295603 4 175461517 [A/G] rs2555639 4 175461530 [T/C] rs9990951 4 175462630 [A/C] rs2256673 4 175463488 [T/C] rs2555674 4 175466101 [A/C] rs1365625 4 175470669 [T/G] rs17060632 4 175475048 [A/G] rs10520286 4 175475745 [A/G] rs6837393 4 175476462 [A/G] rs2555665 4 175479449 [A/G] rs7671048 4 175479552 [T/C] rs7657168 4 175485146 [A/G] rs7687916 4 175485318 [T/C] rs1365621 4 175486220 [T/C] rs6838984 4 175491648 [T/G] rs2332895 4 175492358 [T/C] rs2612655 4 175493589 [T/C] rs2555655 4 175496482 [A/G] rs1820525 4 175497431 [T/C] rs10002363 4 175499617 [A/G] rs2612680 4 175499645 [A/G] rs1426938 4 175500748 [T/C] rs7662981 4 175503770 [T/C] rs2555675 4 175523040 [A/G] rs4695935 4 175523073 [T/C] rs2332838 4 175526690 [T/C] rs12642720 4 175526746 [T/G] rs2555678 4 175528204 [A/C] rs4315752 4 175535392 [A/G] rs12505186 4 175535408 [T/C] rs10006199 4 175538525 [T/C] rs6846164 4 175543263 [T/C] rs9685165 4 175543957 [A/C] rs4695937 4 175552622 [T/C] rs9999152 4 175556222 [T/G] rs6849847 4 175562084 [A/C] rs10213103 4 175562962 [T/G] rs4235212 4 175565245 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs9998793 4 175570846 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs4695945 4 175571589 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs12511536 4 175579442 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs4425356 4 175582984 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs7686453 4 175585803 [A/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs12647358 4 175601668 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs13142152 4 175602273 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs4627838 4 175602762 [A/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs1352058 4 175606405 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs4695784 4 175608905 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs1471817 4 175610550 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs6553806 4 175615500 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs4695952 4 175621502 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs10023637 4 175628121 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs4695954 4 175631986 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs1485945 4 175632405 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs4602476 4 175633768 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs10024014 4 175637324 [A/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs4594702 4 175641906 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs10000984 4 175644564 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs12650824 4 175644689 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs10000456 4 175649941 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs9312559 4 175650116 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs11133053 4 175652512 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs9999658 4 175654447 [A/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs4695959 4 175658175 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs6827308 4 175662891 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs7685430 4 175667791 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs13113891 4 175674144 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs2029570 4 175675480 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs1352804 4 175685891 [A/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs2029569 4 175686589 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs12651268 4 175688141 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 EXON Synonymous_S80S,Synonymous_S80S rs6858127 4 175690792 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs1385838 4 175696544 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs2200457 4 175699276 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs9992190 4 175707292 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs10049967 4 175709806 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs10021711 4 175711800 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs4695963 4 175713278 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs11934209 4 175716041 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs1994313 4 175716626 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs6825046 4 175723995 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs1485938 4 175724056 [T/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs1352062 4 175734620 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs11931453 4 175737847 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs6824735 4 175740569 [T/C] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs6840133 4 175743525 [A/G] NM_001042543,NM_006529 GLRA3,GLRA3 Silent,Silent rs13116721 4 175753571 [A/G] NR_125900 LOC101928551 Silent rs7437645 4 175753871 [T/C] NR_125900 LOC101928551 Silent rs17300435 4 175761435 [A/G] NR_125900 LOC101928551 Silent rs1074475 4 175764593 [T/C] NR_125900 LOC101928551 Silent rs1491411 4 175777871 [T/C] NR_125900 LOC101928551 Silent rs992363 4 175792412 [A/G] NR_125900 LOC101928551 Silent rs1121336 4 175796630 [T/C] NR_125900 LOC101928551 Silent rs7667865 4 175798347 [A/G] rs2029566 4 175801325 [T/G] rs10030900 4 175803167 [T/G] rs6858430 4 175816129 [T/C] rs11933901 4 175816341 [A/G] rs10003605 4 175817225 [A/G] rs7697216 4 175828036 [T/C] rs4388065 4 175831859 [T/C] rs6553847 4 175836048 [A/G] rs6553849 4 175838816 [A/G] rs1104945 4 175839432 [A/C] rs12647292 4 175854023 [A/G] NM_001130703,NM_001130704,NM_001130705,NM_001278126,NM_001278125,NM_014269,NM_001278127 ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4695984 4 175858796 [T/C] NM_001130703,NM_001130704,NM_001130705,NM_001278126,NM_001278125,NM_014269,NM_001278127 ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13147656 4 175859612 [A/G] NM_001130703,NM_001130704,NM_001130705,NM_001278126,NM_001278125,NM_014269,NM_001278127 ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11934547 4 175860563 [A/C] NM_001130703,NM_001130704,NM_001130705,NM_001278126,NM_001278125,NM_014269,NM_001278127 ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13136874 4 175862049 [T/C] NM_001130703,NM_001130704,NM_001130705,NM_001278126,NM_001278125,NM_014269,NM_001278127 ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6841547 4 175870922 [T/C] NM_001130703,NM_001130704,NM_001130705,NM_001278126,NM_001278125,NM_014269,NM_001278127 ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13130150 4 175876473 [T/C] NM_001130703,NM_001130704,NM_001130705,NM_001278126,NM_001278125,NM_014269,NM_001278127 ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7661012 4 175878038 [A/G] NM_001130703,NM_001130704,NM_001130705,NM_001278126,NM_001278125,NM_014269,NM_001278127 ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10001087 4 175880491 [T/C] NM_001130703,NM_001130704,NM_001130705,NM_001278126,NM_001278125,NM_014269,NM_001278127 ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4128922 4 175890127 [A/G] NM_001130703,NM_001130704,NM_001130705,NM_001278126,NM_001278125,NM_014269,NM_001278127 ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4129839 4 175891945 [T/C] NM_001130703,NM_001130704,NM_001130705,NM_001278126,NM_001278125,NM_014269,NM_001278127 ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6845431 4 175894380 [A/C] NM_001130703,NM_001130704,NM_001130705,NM_001278126,NM_001278125,NM_014269,NM_001278127 ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29,ADAM29 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs28833210 4 175908720 [T/C] rs10026079 4 175913798 [T/C] rs12502984 4 175923101 [A/C] rs11734965 4 175926862 [A/G] rs10461333 4 175928058 [T/C] rs2127292 4 175929930 [A/C] rs6553853 4 175936490 [A/C] rs12513233 4 175939626 [A/G] rs4382019 4 175947638 [T/C] rs12509972 4 175948807 [A/C] rs11932717 4 175950601 [A/C] rs11941955 4 175954666 [T/G] rs1842178 4 175964181 [A/G] rs1471480 4 175967160 [T/C] rs1479380 4 175968691 [T/C] rs7356528 4 175970464 [A/G] rs1491413 4 175987359 [A/G] rs7692765 4 175997773 [T/C] rs11733561 4 176009525 [A/G] rs11934037 4 176018734 [A/G] rs330500 4 176022589 [T/C] rs330502 4 176023652 [T/C] rs1352806 4 176027111 [T/G] rs1602491 4 176031901 [A/G] rs2219824 4 176036504 [A/G] rs330493 4 176042191 [A/G] rs6849435 4 176055295 [T/C] rs6811622 4 176056502 [T/G] rs4695809 4 176066263 [A/C] rs1479377 4 176073580 [T/C] rs162449 4 176090779 [A/G] rs6851302 4 176091913 [A/G] rs331488 4 176095286 [A/G] rs162465 4 176098008 [A/G] rs162471 4 176104892 [T/C] rs1491416 4 176109168 [T/C] rs654089 4 176110924 [T/G] rs1552703 4 176113176 [A/G] rs11133085 4 176113346 [T/C] rs13142619 4 176116299 [T/C] rs13134673 4 176122398 [T/G] rs13134743 4 176122493 [T/C] rs2637795 4 176124452 [A/G] rs647003 4 176126370 [T/C] rs6812564 4 176126818 [A/C] rs4286499 4 176136330 [T/G] rs7673876 4 176152373 [T/G] rs661027 4 176156361 [A/G] rs10014039 4 176161041 [T/G] rs4146 4 176164722 [T/C] rs13132343 4 176170783 [A/G] rs493293 4 176176194 [T/C] rs13146658 4 176181659 [T/C] rs11728856 4 176184425 [T/C] rs4696017 4 176184572 [A/G] rs4696019 4 176195262 [A/G] rs7673394 4 176200230 [T/C] rs17377586 4 176207936 [T/G] rs7694183 4 176213508 [A/G] rs10520296 4 176214028 [A/G] rs1711988 4 176226337 [T/C] rs4417946 4 176227974 [A/G] rs693803 4 176228249 [T/G] rs6844935 4 176246005 [A/C] rs13133504 4 176252966 [T/C] rs13135411 4 176257561 [A/G] rs6819416 4 176268641 [T/C] rs2333163 4 176270885 [T/C] rs2333164 4 176282610 [T/C] rs2333166 4 176285962 [T/C] rs1879629 4 176289800 [A/G] rs13103867 4 176298798 [T/C] rs10004878 4 176320993 [A/G] rs9994051 4 176344294 [T/C] rs9684098 4 176349829 [A/G] rs4690629 4 176363930 [A/G] rs9990657 4 176366005 [A/G] rs13434491 4 176366314 [A/G] rs13149814 4 176370331 [T/G] rs3923340 4 176370543 [A/G] rs10021387 4 176378939 [T/C] rs7699269 4 176393194 [A/G] rs13107001 4 176399587 [A/G] rs6829020 4 176410587 [A/C] rs11934266 4 176414843 [A/G] rs7664499 4 176416416 [A/C] rs10015016 4 176432982 [A/G] rs4622948 4 176451803 [A/G] rs9992999 4 176480544 [A/C] rs4311268 4 176487623 [T/G] rs11735559 4 176491850 [A/C] rs12502137 4 176502740 [A/C] rs13111738 4 176513040 [T/C] rs4690379 4 176514624 [A/G] rs4073222 4 176526911 [A/G] rs2333233 4 176538654 [T/C] rs10027928 4 176541897 [T/G] rs4690535 4 176545324 [A/G] rs10006242 4 176546320 [A/G] rs11728358 4 176547576 [A/G] rs1014381 4 176548782 [A/G] rs2333243 4 176549722 [A/G] rs13132334 4 176553337 [T/C] rs3733398 4 176555585 [A/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A EXON Silent,Silent,Silent,Silent,Silent,Silent rs7691882 4 176556472 [A/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs10520301 4 176560091 [T/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs17313669 4 176560547 [A/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2333251 4 176566551 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs7678146 4 176566962 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs4429679 4 176571011 [A/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2333255 4 176582766 [A/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs11940383 4 176587929 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs6553892 4 176589580 [A/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs35424424 4 176591669 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs6821481 4 176593249 [A/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs10213204 4 176601113 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs10520302 4 176608039 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2333257 4 176609256 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs17061779 4 176610969 [A/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs17061785 4 176612351 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs12640626 4 176626272 [A/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs12512924 4 176626693 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs10022458 4 176632858 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2581761 4 176641467 [A/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2644005 4 176641650 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2644007 4 176644662 [A/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs1472328 4 176644821 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs9284954 4 176648332 [A/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs9312583 4 176648393 [A/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2015588 4 176650816 [A/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs7685659 4 176651926 [T/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2644002 4 176652429 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs17061928 4 176655160 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2581750 4 176657585 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs13152426 4 176660420 [A/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs1845732 4 176662797 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs13144140 4 176666186 [A/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2643988 4 176667918 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs1472324 4 176670796 [T/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2643990 4 176671191 [A/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs10011322 4 176672144 [A/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2047246 4 176673554 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2643991 4 176674283 [A/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs17658370 4 176676303 [A/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs722825 4 176677770 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2581771 4 176684193 [A/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs17061991 4 176690799 [A/G] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs2643998 4 176698383 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs1390343 4 176706135 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs17062019 4 176707862 [T/C] NM_201591,NM_201592,NM_005277,NM_001261448,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent,Silent rs13140287 4 176711191 [A/G] NM_201591,NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent,Silent rs13113026 4 176716522 [T/C] NM_201591,NM_201592,NM_005277,NM_001261447,NR_048571,NR_125901 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,LOC101928590 Silent,Silent,Silent,Silent,Silent,Silent rs1495716 4 176728576 [T/C] NM_201591,NM_201592,NM_005277,NM_001261447,NR_048571,NR_125901 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,LOC101928590 Silent,Silent,Silent,Silent,Silent,Silent rs13142920 4 176728614 [A/C] NM_201591,NM_201592,NM_005277,NM_001261447,NR_048571,NR_125901 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,LOC101928590 Silent,Silent,Silent,Silent,Silent,Silent rs2291761 4 176730094 [A/C] NM_201591,NM_201592,NM_005277,NM_001261447,NR_048571,NR_125901 GPM6A,GPM6A,GPM6A,GPM6A,GPM6A,LOC101928590 Silent,Silent,Silent,Silent,Silent,Silent rs2132339 4 176745747 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs6838421 4 176747173 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs1027409 4 176748078 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs11133116 4 176754093 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs17062130 4 176754675 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs12509237 4 176759170 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs10033784 4 176766796 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs10520312 4 176768164 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs17062168 4 176772769 [T/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs11940577 4 176782054 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs17062188 4 176792194 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs4306906 4 176795898 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs17052287 4 176798213 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs1826763 4 176804052 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs17062218 4 176818931 [A/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs11133119 4 176820049 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs10049819 4 176820095 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs7436322 4 176823651 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs10033742 4 176825221 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs903650 4 176827467 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs17062227 4 176828539 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs10520316 4 176831865 [A/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs17062252 4 176832899 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs1495714 4 176837789 [A/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs7438439 4 176838690 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs9686024 4 176839335 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs9683504 4 176839524 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs6818081 4 176840816 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs17062274 4 176850196 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs1106568 4 176861301 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs34044173 4 176869131 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs10001442 4 176872136 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs4690647 4 176872920 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs10520320 4 176880351 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs7658712 4 176882871 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs6848709 4 176890925 [T/C] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs17062345 4 176902231 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs7675676 4 176918741 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs6553899 4 176922278 [A/G] NM_201592,NM_005277,NM_001261447,NR_048571 GPM6A,GPM6A,GPM6A,GPM6A Silent,Silent,Silent,Silent rs1471797 4 176924716 [T/C] rs1471798 4 176926946 [A/G] rs997779 4 176936038 [A/C] rs11936134 4 176949352 [T/C] rs11133123 4 176950029 [T/C] rs12499459 4 176957224 [A/G] rs6823563 4 176957395 [T/C] rs11721843 4 176963980 [T/C] rs12500840 4 176966664 [A/G] rs17669562 4 176970155 [A/G] rs973732 4 176971792 [T/G] rs6553905 4 176973932 [A/G] rs13146736 4 176975408 [T/C] rs7692309 4 176976075 [A/C] rs7657735 4 176978086 [A/G] rs2333391 4 176980809 [A/G] rs1385614 4 176993039 [T/C] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 Silent,Silent,Silent rs12641442 4 177006043 [T/C] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 Silent,Silent,Silent rs9997517 4 177006484 [A/G] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 Silent,Silent,Silent rs17062501 4 177014804 [A/G] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 Silent,Silent,Silent rs17624517 4 177016992 [A/G] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 Silent,Silent,Silent rs10009701 4 177045953 [A/G] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 Silent,Silent,Silent rs7678897 4 177061748 [T/C] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 Silent,Silent,Silent rs4690661 4 177073026 [A/G] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 EXON Missense_A814T,Missense_A814T,Missense_A790T rs2128422 4 177079374 [T/C] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 Silent,Silent,Silent rs2170576 4 177085016 [T/C] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 Silent,Silent,Silent rs4475089 4 177091829 [A/G] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 Silent,Silent,Silent rs11133133 4 177091853 [T/C] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 Silent,Silent,Silent rs4690665 4 177095908 [A/G] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 Silent,Silent,Silent rs17625943 4 177098285 [A/G] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 EXON Missense_A1207T,Missense_A1215T,Missense_A1176T rs11736872 4 177100644 [A/G] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 EXON Missense_A1287T,Missense_A1295T,Missense_A1256T rs7699964 4 177101060 [T/G] NM_001350727,NM_170710,NM_181265 WDR17,WDR17,WDR17 EXON Silent,Silent,Silent rs11133135 4 177105388 [A/G] rs17062566 4 177106716 [A/C] NM_144644 SPATA4 Silent rs2333402 4 177107335 [T/G] NM_144644 SPATA4 Silent rs6824664 4 177112552 [T/C] NM_144644 SPATA4 Silent rs12502935 4 177113779 [T/C] NM_144644 SPATA4 EXON Synonymous_P229P rs6832177 4 177113836 [T/C] NM_144644 SPATA4 EXON Synonymous_A210A rs2291244 4 177113956 [A/G] NM_144644 SPATA4 EXON Synonymous_Y170Y rs6820936 4 177114889 [T/C] NM_144644 SPATA4 Silent rs1905184 4 177117349 [A/G] rs10004500 4 177119860 [A/C] rs728846 4 177121983 [T/C] rs13105191 4 177123419 [A/C] rs11731185 4 177123850 [A/C] rs4626145 4 177124254 [A/G] rs2333406 4 177126245 [A/G] rs11133136 4 177127021 [A/G] rs17672498 4 177129266 [A/G] rs17062621 4 177131268 [A/G] rs13120122 4 177134283 [T/C] rs10003543 4 177135620 [A/G] NM_080874 ASB5 EXON Silent rs13109244 4 177136149 [A/G] NM_080874 ASB5 EXON Silent rs922849 4 177136512 [A/G] NM_080874 ASB5 EXON Silent rs17062628 4 177137373 [A/G] NM_080874 ASB5 Silent rs6827525 4 177137988 [T/C] NM_080874 ASB5 EXON Synonymous_R281R rs10032098 4 177142776 [A/C] NM_080874 ASB5 Silent rs6830358 4 177143727 [T/G] NM_080874 ASB5 Silent rs6814870 4 177144364 [T/C] NM_080874 ASB5 Silent rs10013975 4 177146627 [T/C] NM_080874 ASB5 Silent rs17673171 4 177149518 [T/C] NM_080874 ASB5 Silent rs1351632 4 177150491 [T/C] NM_080874 ASB5 Silent rs2046262 4 177150925 [A/G] NM_080874 ASB5 Silent rs13117768 4 177154323 [T/C] NM_080874 ASB5 Silent rs7684092 4 177157830 [A/G] NM_080874 ASB5 Silent rs7688636 4 177160262 [A/G] NM_080874 ASB5 Silent rs9991242 4 177162117 [A/G] NM_080874 ASB5 Silent rs9312595 4 177163414 [A/G] NM_080874 ASB5 Silent rs9790840 4 177164064 [T/C] NM_080874 ASB5 Silent rs4690671 4 177165556 [T/G] NM_080874 ASB5 Silent rs17679314 4 177167740 [T/C] NM_080874 ASB5 Silent rs10520340 4 177180575 [A/G] NM_080874 ASB5 Silent rs10005873 4 177184276 [T/C] NM_080874 ASB5 Silent rs17628329 4 177184716 [T/C] NM_080874 ASB5 Silent rs1454167 4 177186882 [T/C] NM_080874 ASB5 Silent rs12649379 4 177194007 [A/G] rs6820078 4 177195145 [A/G] rs13129947 4 177202275 [A/G] rs4690681 4 177202400 [T/G] rs4690682 4 177202549 [A/G] rs11133142 4 177212135 [A/G] rs13115859 4 177224449 [T/C] rs12507341 4 177227998 [T/C] rs6553943 4 177232708 [T/C] rs7670905 4 177233904 [T/C] rs13115857 4 177234129 [T/G] rs723820 4 177234906 [A/G] rs9992247 4 177235286 [T/C] rs13130930 4 177235586 [T/C] rs4305467 4 177237317 [A/G] rs11735748 4 177237359 [T/C] rs17062749 4 177237631 [A/G] rs1454162 4 177239269 [T/C] rs1454160 4 177239338 [T/C] rs4690686 4 177242959 [T/C] NM_021928 SPCS3 Silent rs17681035 4 177244326 [A/G] NM_021928 SPCS3 Silent rs3733370 4 177250182 [T/G] NM_021928 SPCS3 EXON Silent rs17629999 4 177250491 [T/C] NM_021928 SPCS3 EXON Silent rs13117427 4 177255407 [A/G] rs10027831 4 177256699 [T/C] rs4690687 4 177259635 [A/G] rs4690429 4 177263983 [A/G] rs7694145 4 177285894 [A/G] rs1454158 4 177290945 [A/G] rs13144122 4 177292032 [A/C] rs2085061 4 177294407 [T/G] rs11944672 4 177296975 [T/G] rs7682500 4 177298249 [T/C] rs11932699 4 177307459 [T/C] rs6553951 4 177308667 [A/G] rs13139292 4 177308956 [A/G] rs17631173 4 177310481 [A/G] rs4690696 4 177314797 [T/C] rs12647397 4 177322096 [A/G] rs10018184 4 177324650 [A/C] rs2123861 4 177328296 [T/C] rs6832586 4 177334892 [T/C] rs6553957 4 177336067 [A/G] rs12331128 4 177337800 [A/C] rs11133152 4 177339963 [A/G] rs4690437 4 177340086 [A/C] rs4146092 4 177340623 [A/C] rs6553961 4 177343885 [T/C] rs2167094 4 177350693 [T/C] rs10009750 4 177355622 [T/C] rs4690442 4 177358612 [A/G] rs28562735 4 177359397 [T/C] rs921691 4 177360669 [A/G] rs1377841 4 177366729 [T/C] rs17062990 4 177371366 [A/G] rs2167096 4 177372753 [A/G] rs2167095 4 177373302 [T/C] rs309753 4 177374643 [A/C] rs6837598 4 177378346 [T/C] rs365051 4 177391167 [T/C] rs309732 4 177394679 [A/G] rs309729 4 177396008 [A/G] rs13132587 4 177397059 [T/C] rs4146433 4 177400257 [T/C] rs309719 4 177401671 [T/G] rs4690445 4 177406393 [T/G] rs10866385 4 177406476 [A/C] rs11133155 4 177410613 [A/G] rs17063153 4 177419021 [T/G] rs4690351 4 177419908 [A/G] rs1375738 4 177420945 [A/G] rs403742 4 177422510 [A/G] rs309703 4 177429154 [A/G] rs448336 4 177430724 [T/C] rs17063208 4 177430980 [A/G] rs377413 4 177436430 [T/C] rs416203 4 177440967 [A/G] rs12500053 4 177442955 [A/G] rs425571 4 177444335 [A/G] rs13115445 4 177460096 [T/C] rs1375749 4 177461365 [A/G] rs309780 4 177462810 [A/G] rs309789 4 177464940 [A/G] rs309794 4 177466128 [T/C] rs309798 4 177466797 [T/C] rs11133161 4 177466989 [A/G] rs13133225 4 177467220 [A/G] rs309800 4 177467880 [A/C] rs13137758 4 177469451 [A/G] rs17688093 4 177469539 [A/G] rs13148526 4 177469582 [T/C] rs2034861 4 177478482 [T/G] rs6819712 4 177481511 [A/G] rs4690449 4 177482558 [A/G] rs6811119 4 177490180 [T/G] rs17688977 4 177490659 [A/G] rs13132894 4 177494726 [A/G] rs13133307 4 177494883 [A/G] rs13117732 4 177496193 [A/G] rs10023049 4 177497169 [A/G] rs17063321 4 177497542 [T/G] rs6811268 4 177497711 [A/G] rs13119438 4 177507768 [T/G] rs1449749 4 177508930 [A/G] rs11725315 4 177514623 [A/C] rs12644889 4 177522973 [A/G] rs1017912 4 177529489 [T/G] rs13131892 4 177529663 [T/C] rs7660760 4 177530812 [T/G] rs6553973 4 177531472 [T/C] rs6824464 4 177531891 [A/G] rs17063414 4 177533410 [T/C] rs7663611 4 177539619 [A/G] rs13111989 4 177542973 [A/G] rs2062416 4 177544609 [T/C] rs871927 4 177548580 [T/C] rs1002976 4 177548598 [T/C] rs9994958 4 177551631 [A/C] rs17063436 4 177555700 [A/G] rs13144350 4 177561651 [A/G] rs13135363 4 177563237 [T/C] rs6852384 4 177566170 [A/G] rs10029554 4 177568466 [A/C] rs7671044 4 177571116 [A/G] rs17063470 4 177572182 [A/G] rs6842237 4 177573314 [A/G] rs1471810 4 177575052 [A/G] rs10011748 4 177575129 [T/G] rs12505396 4 177575300 [T/G] rs11133168 4 177580725 [A/G] rs4690358 4 177583933 [A/G] rs1385739 4 177586285 [T/G] rs10520358 4 177587894 [T/C] rs6826173 4 177591869 [A/G] rs6816454 4 177602726 [T/C] rs2877961 4 177605696 [A/G] NM_005429 VEGFC Silent rs1485762 4 177607731 [T/C] NM_005429 VEGFC Silent rs7664413 4 177608707 [T/C] NM_005429 VEGFC Silent rs1485766 4 177610884 [T/G] NM_005429 VEGFC Silent rs3775202 4 177611211 [T/C] NM_005429 VEGFC Silent rs3775198 4 177612566 [A/G] NM_005429 VEGFC Silent rs3775195 4 177621110 [T/G] NM_005429 VEGFC Silent rs10007002 4 177621711 [A/G] NM_005429 VEGFC Silent rs1531956 4 177632236 [T/C] NM_005429 VEGFC Silent rs1564922 4 177634522 [A/G] NM_005429 VEGFC Silent rs6820170 4 177645549 [T/C] NM_005429 VEGFC Silent rs3775189 4 177647977 [T/C] NM_005429 VEGFC Silent rs1485767 4 177651791 [A/G] NM_005429 VEGFC Silent rs6838834 4 177653598 [T/C] NM_005429 VEGFC Silent rs475106 4 177656790 [A/G] NM_005429 VEGFC Silent rs10012721 4 177659075 [T/G] NM_005429 VEGFC Silent rs13122901 4 177662092 [A/G] NM_005429 VEGFC Silent rs964812 4 177667073 [T/G] NM_005429 VEGFC Silent rs12641359 4 177678555 [T/C] NM_005429 VEGFC Silent rs4557213 4 177689133 [A/G] NM_005429 VEGFC Silent rs4276244 4 177719218 [A/C] rs11131764 4 177720359 [T/C] rs20533 4 177726720 [A/G] rs13104461 4 177736850 [T/C] rs9992272 4 177737136 [A/G] rs11734535 4 177738885 [T/C] rs17063777 4 177739471 [A/G] rs4690363 4 177740692 [T/C] rs7654391 4 177741229 [T/C] rs17063785 4 177743630 [A/G] rs2333571 4 177761552 [A/G] rs9994879 4 177767619 [T/G] rs10006747 4 177776703 [A/G] rs6552198 4 177785568 [A/G] rs6850178 4 177789086 [T/C] rs13124707 4 177802518 [A/G] rs10034876 4 177802943 [T/C] rs7668750 4 177804746 [T/C] rs7700025 4 177814863 [A/G] rs13105194 4 177815859 [T/G] rs1836829 4 177841949 [A/G] rs1836828 4 177842009 [A/G] rs13152811 4 177842267 [T/G] rs2574904 4 177844568 [T/C] rs1545089 4 177854130 [T/C] rs1436197 4 177862546 [T/G] rs2724754 4 177870509 [A/G] rs873632 4 177870554 [T/G] rs873350 4 177871569 [A/G] rs17063948 4 177880120 [T/C] rs12507320 4 177885655 [A/G] rs6812865 4 177890893 [T/C] rs6813168 4 177891168 [A/G] rs7662445 4 177891850 [A/G] rs13104005 4 177895429 [T/C] rs6837144 4 177897523 [T/G] rs12648879 4 177900078 [T/C] rs13434489 4 177907949 [A/C] rs13110230 4 177916874 [T/G] rs17064016 4 177918145 [A/G] rs7655591 4 177928041 [A/C] rs7663143 4 177952118 [A/G] rs10025425 4 177964148 [T/C] rs17720291 4 177966548 [T/C] rs4282116 4 177968578 [A/C] rs12512817 4 177971842 [A/C] rs13112548 4 177974062 [A/C] rs17064100 4 177974921 [A/G] rs17064106 4 177975350 [A/G] rs10004643 4 177976662 [A/G] rs10780058 4 177982668 [T/C] rs2583194 4 177993233 [T/C] rs1561488 4 177999318 [T/G] rs3114031 4 178001276 [A/C] rs1866505 4 178008182 [A/C] rs12639884 4 178013213 [T/C] rs4398480 4 178016011 [A/G] rs17064260 4 178017550 [T/C] rs6846031 4 178019148 [T/G] rs997164 4 178019581 [A/C] rs1898854 4 178028186 [A/G] rs2580062 4 178029963 [T/C] rs10014557 4 178030644 [T/C] rs13124830 4 178036711 [T/C] rs17064315 4 178041034 [A/G] rs13130688 4 178043001 [T/C] rs12501567 4 178045600 [A/G] rs2580069 4 178049288 [A/G] rs2635835 4 178052785 [A/G] rs9996167 4 178056849 [A/C] rs10019190 4 178057346 [A/C] rs1439343 4 178061968 [A/G] rs7656045 4 178069059 [A/G] rs13125748 4 178069165 [A/C] rs6838906 4 178072504 [A/G] rs1439349 4 178076860 [T/C] rs4299533 4 178084093 [T/C] rs2583221 4 178089529 [T/C] rs2583165 4 178092059 [A/C] rs1489958 4 178093317 [T/C] rs2246360 4 178100729 [T/G] rs966023 4 178106459 [T/C] rs13105496 4 178116819 [T/C] rs4690374 4 178123945 [A/G] rs17064420 4 178128842 [T/C] rs11723785 4 178136407 [T/C] rs4690502 4 178141976 [A/G] rs1992264 4 178145355 [T/C] rs2580051 4 178146619 [T/G] rs1009523 4 178151435 [T/C] rs4690376 4 178152242 [A/G] rs6821871 4 178152876 [A/G] rs6821735 4 178153009 [A/G] rs11942838 4 178160453 [T/G] rs11734226 4 178160858 [T/C] rs2118922 4 178167074 [A/G] rs17064500 4 178168551 [T/C] rs3828517 4 178169500 [A/G] rs10005919 4 178170776 [A/G] rs9761093 4 178173007 [A/G] rs1542722 4 178178160 [T/C] rs9784497 4 178181681 [T/C] rs13125007 4 178184819 [T/C] rs17725302 4 178186997 [A/G] rs11131790 4 178193637 [A/G] rs9684452 4 178194441 [T/C] rs1567111 4 178197237 [T/C] rs17064538 4 178199981 [T/C] rs4690504 4 178201257 [T/C] rs10520376 4 178203463 [A/G] rs13144731 4 178206711 [A/G] rs2046824 4 178208526 [T/C] rs1844483 4 178209089 [T/C] rs11131791 4 178213319 [A/G] rs17064564 4 178214726 [A/C] rs17064578 4 178221198 [T/C] rs2068197 4 178224638 [A/G] rs2135617 4 178225675 [T/G] rs17726200 4 178229612 [T/G] rs10009807 4 178229925 [A/G] rs17064587 4 178231071 [A/G] NM_018248 NEIL3 EXON Silent rs10013040 4 178231152 [A/C] NM_018248 NEIL3 EXON Synonymous_R15R rs6817959 4 178235334 [A/C] NM_018248 NEIL3 Silent rs6850861 4 178236402 [T/C] NM_018248 NEIL3 Silent rs6856628 4 178236896 [T/G] NM_018248 NEIL3 Silent rs17064612 4 178238253 [T/C] NM_018248 NEIL3 Silent rs17064613 4 178238330 [A/G] NM_018248 NEIL3 Silent rs6830266 4 178242398 [A/G] NM_018248 NEIL3 Silent rs6834946 4 178242537 [T/C] NM_018248 NEIL3 Silent rs12642885 4 178247400 [A/G] NM_018248 NEIL3 Silent rs2048076 4 178255747 [A/G] NM_018248 NEIL3 Silent rs7689099 4 178256913 [G/C] NM_018248 NEIL3 EXON Missense_P117R rs17064661 4 178259934 [T/C] NM_018248 NEIL3 Silent rs867612 4 178260268 [A/G] NM_018248 NEIL3 Silent rs12645561 4 178260872 [T/C] NM_018248 NEIL3 Silent rs11940019 4 178261895 [A/G] NM_018248 NEIL3 Silent rs1983130 4 178268663 [T/G] NM_018248 NEIL3 Silent rs2877985 4 178268897 [A/G] NM_018248 NEIL3 Silent rs12501016 4 178269253 [A/G] NM_018248 NEIL3 Silent rs9637678 4 178269670 [A/G] NM_018248 NEIL3 Silent rs2048073 4 178270916 [A/G] NM_018248 NEIL3 Silent rs17064676 4 178272700 [A/G] NM_018248 NEIL3 EXON Missense_I346V rs1054753 4 178272748 [A/G] NM_018248 NEIL3 Silent rs3805169 4 178272916 [T/C] NM_018248 NEIL3 Silent rs3828488 4 178273030 [A/G] NM_018248 NEIL3 Silent rs10007075 4 178274694 [T/G] NM_018248 NEIL3 EXON Synonymous_V424V rs13112358 4 178274750 [T/C] NM_018248 NEIL3 EXON Missense_P443L rs13112390 4 178274835 [A/C] NM_018248 NEIL3 EXON Missense_Q471H rs13140743 4 178275220 [T/C] NM_018248 NEIL3 Silent rs9994685 4 178280031 [A/G] NM_018248 NEIL3 Silent rs12507296 4 178280473 [A/G] NM_018248 NEIL3 Silent rs1876268 4 178281754 [A/G] NM_018248 NEIL3 EXON Missense_G520R rs1055678 4 178283967 [T/C] NM_018248 NEIL3 EXON Silent rs10025089 4 178285610 [T/C] rs7667508 4 178287162 [T/C] rs17090614 4 178288939 [A/G] rs6846587 4 178290368 [T/C] rs6830385 4 178291257 [T/C] rs1506811 4 178294146 [T/C] rs17739370 4 178295429 [T/C] rs17064756 4 178295725 [T/C] rs4690508 4 178295766 [T/G] rs17739461 4 178296647 [T/C] rs9312207 4 178296863 [T/G] rs11131792 4 178297365 [T/C] rs1395480 4 178297393 [T/C] rs17677649 4 178298024 [A/G] rs10866214 4 178299038 [T/G] rs7671847 4 178299498 [A/G] rs17677777 4 178301110 [T/C] rs6832432 4 178309091 [T/C] rs5004774 4 178310307 [T/G] rs13108563 4 178310766 [T/G] rs17064782 4 178313274 [A/G] rs17064783 4 178313450 [T/C] rs17739994 4 178313514 [A/C] rs2135615 4 178314542 [A/C] rs1506807 4 178317692 [A/G] rs12506969 4 178320300 [A/G] rs17064813 4 178321406 [A/G] rs1395483 4 178321418 [T/C] rs4690513 4 178327053 [T/C] rs6552231 4 178327855 [T/C] rs17064824 4 178328596 [T/G] rs17064825 4 178328886 [A/G] rs1911239 4 178335508 [A/G] rs1588051 4 178337145 [A/G] rs4690516 4 178340126 [T/C] rs4690517 4 178346941 [A/G] rs12641389 4 178351295 [T/C] rs3749480 4 178351803 [A/G] rs3828487 4 178353473 [A/C] NM_001171988,NR_033655,NM_000027 AGA,AGA,AGA Silent,Silent,Silent rs2279932 4 178354886 [A/G] NM_001171988,NR_033655,NM_000027 AGA,AGA,AGA Silent,Silent,Silent rs12499096 4 178356930 [A/G] NM_001171988,NR_033655,NM_000027 AGA,AGA,AGA Silent,Silent,Silent rs2271100 4 178359679 [T/C] NM_001171988,NR_033655,NM_000027 AGA,AGA,AGA Silent,Silent,Silent rs4690522 4 178361051 [A/C] NM_001171988,NR_033655,NM_000027 AGA,AGA,AGA Silent,Silent,Silent rs4690523 4 178361162 [T/C] NM_001171988,NR_033655,NM_000027 AGA,AGA,AGA Silent,Silent,Silent rs7680586 4 178369766 [T/C] rs6847279 4 178374869 [A/G] rs17064851 4 178377527 [T/C] rs17064860 4 178381669 [A/C] rs12504521 4 178384657 [A/G] rs7693160 4 178387902 [A/G] rs6852945 4 178388432 [T/G] rs17064875 4 178390897 [T/G] rs4690525 4 178392708 [T/C] rs35955682 4 178393335 [A/G] rs6823035 4 178394279 [A/G] rs6814553 4 178405429 [A/G] rs17742216 4 178419101 [T/C] rs11944393 4 178426799 [T/C] rs17742420 4 178438637 [A/G] rs10022632 4 178439917 [A/G] rs1882160 4 178449352 [A/G] rs12510932 4 178454290 [A/C] rs6812233 4 178455524 [T/C] rs6827612 4 178460162 [A/G] rs4047774 4 178471300 [A/G] rs4615129 4 178471973 [A/G] rs10866215 4 178474945 [A/G] rs1920975 4 178477452 [A/G] rs1316294 4 178479822 [A/G] rs4690536 4 178491443 [A/G] rs13435280 4 178497759 [T/C] rs10015045 4 178498527 [T/C] rs1920969 4 178500973 [A/G] rs12509926 4 178501916 [T/C] rs13116233 4 178503993 [A/C] rs17065006 4 178506363 [T/G] rs17743886 4 178509336 [T/C] rs11732864 4 178510236 [T/C] rs6816548 4 178511146 [A/G] rs13114753 4 178516328 [A/G] rs6834239 4 178517058 [T/C] rs17749802 4 178520166 [A/G] rs10866216 4 178524155 [T/C] rs7661921 4 178536315 [A/G] rs10520382 4 178538777 [A/G] rs13102468 4 178556723 [A/C] rs10019475 4 178564250 [T/C] rs13147867 4 178579037 [A/G] rs13149928 4 178593268 [T/C] rs10005304 4 178594516 [A/G] rs4443228 4 178594906 [A/G] rs4690549 4 178596794 [A/C] rs9684887 4 178597709 [A/G] rs6845027 4 178598308 [A/G] rs4690554 4 178599771 [T/C] rs12502947 4 178607009 [T/C] rs4432701 4 178617740 [A/G] rs1993279 4 178620683 [A/G] rs1993280 4 178621004 [T/C] rs1993281 4 178621097 [A/G] rs6838111 4 178641317 [T/C] rs1993278 4 178643884 [T/C] rs1454212 4 178644817 [A/G] rs1454213 4 178646542 [T/C] rs3943470 4 178649091 [T/C] rs11730575 4 178651027 [A/G] NR_028342 LINC01098 Silent rs4690560 4 178662910 [A/G] NR_028342 LINC01098 Silent rs9312212 4 178669888 [A/G] NR_028342 LINC01098 Silent rs4690563 4 178674077 [T/G] NR_028342 LINC01098 Silent rs6829056 4 178678485 [T/C] NR_028342 LINC01098 Silent rs17065167 4 178678514 [A/G] NR_028342 LINC01098 Silent rs10222887 4 178681212 [T/G] NR_028342 LINC01098 Silent rs6851156 4 178682034 [T/G] NR_028342 LINC01098 Silent rs7698744 4 178682882 [A/G] NR_028342 LINC01098 Silent rs11131820 4 178683325 [T/C] NR_028342 LINC01098 Silent rs17700785 4 178686626 [T/C] NR_028342 LINC01098 Silent rs2085067 4 178689242 [T/C] NR_028342 LINC01098 Silent rs7691749 4 178692400 [A/G] NR_028342 LINC01098 Silent rs13140117 4 178701283 [A/G] NR_028342 LINC01098 Silent rs1902019 4 178710704 [A/G] NR_028342 LINC01098 Silent rs12508860 4 178710940 [A/C] NR_028342 LINC01098 Silent rs10011916 4 178711450 [T/C] NR_028342 LINC01098 Silent rs1454218 4 178713104 [A/C] NR_028342 LINC01098 Silent rs17751904 4 178715833 [A/G] NR_028342 LINC01098 Silent rs17752004 4 178718914 [T/C] NR_028342 LINC01098 Silent rs10017412 4 178721539 [A/G] NR_028342 LINC01098 Silent rs975438 4 178731036 [A/G] NR_028342 LINC01098 Silent rs11723791 4 178734746 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs4997950 4 178740648 [T/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs17090615 4 178745616 [T/C] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs1377859 4 178749087 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs4574348 4 178752567 [T/C] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs10049757 4 178754587 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs6827227 4 178755843 [T/C] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs6843725 4 178759663 [T/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs17065284 4 178759888 [T/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs1869511 4 178760454 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs11131829 4 178760909 [T/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs2378775 4 178762043 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs2168041 4 178770448 [T/C] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs12643723 4 178772728 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs11131831 4 178773349 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs17065359 4 178774778 [T/C] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs17065363 4 178775388 [T/C] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs10015482 4 178776011 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs6849372 4 178776502 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs1454208 4 178791367 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs4690581 4 178793689 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs9684037 4 178793878 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs2168040 4 178794478 [T/C] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs4690582 4 178797990 [T/C] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs11722051 4 178799980 [T/C] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs6824106 4 178801018 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs11725712 4 178803423 [T/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs6851593 4 178805083 [A/C] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs4277728 4 178806432 [T/C] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs4306905 4 178806449 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs2219692 4 178812009 [T/C] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs13110833 4 178813276 [T/C] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs13118487 4 178817591 [A/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs2378799 4 178820545 [T/G] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs11939187 4 178821372 [T/C] NR_028342,NR_108092 LINC01098,LINC01099 Silent,Silent rs17065447 4 178827897 [T/G] NR_028342,NR_108092,NR_108093 LINC01098,LINC01099,LINC01099 Silent,Silent,Silent rs17703021 4 178836429 [T/C] NR_028342 LINC01098 Silent rs12645056 4 178841353 [T/G] NR_028342 LINC01098 Silent rs1381703 4 178847967 [A/G] NR_028342 LINC01098 Silent rs11131839 4 178870639 [A/C] NR_028342 LINC01098 Silent rs2126506 4 178873922 [T/C] NR_028342 LINC01098 Silent rs7673686 4 178883188 [T/C] NR_028342 LINC01098 Silent rs8180172 4 178888659 [A/G] NR_028342 LINC01098 Silent rs10049911 4 178891271 [T/C] NR_028342 LINC01098 Silent rs10049915 4 178891411 [T/C] NR_028342 LINC01098 Silent rs10006596 4 178910307 [T/C] NR_028342 LINC01098 Silent rs1599605 4 178910702 [T/C] NR_028342 LINC01098 Silent rs17065494 4 178911822 [T/C] NR_028342 LINC01098 EXON Silent rs17065497 4 178911873 [A/G] NR_028342 LINC01098 EXON Silent rs10010019 4 178914733 [T/C] rs1462513 4 178915050 [T/G] rs12641431 4 178918074 [A/G] rs1462514 4 178922921 [A/G] rs1711390 4 178933641 [A/G] rs2054380 4 178943989 [A/G] rs2054381 4 178944245 [A/C] rs1676169 4 178951714 [A/G] rs1711376 4 178955488 [A/G] rs2045757 4 178962336 [A/G] rs1676177 4 178967175 [A/G] rs1676187 4 178978140 [T/C] rs1381698 4 178979494 [T/C] rs1676196 4 178981852 [T/G] rs1711386 4 178988148 [T/C] rs1462505 4 179002061 [T/C] rs1711391 4 179004868 [T/C] rs10520402 4 179005829 [T/C] rs6552275 4 179009622 [A/G] rs1632770 4 179010647 [T/C] rs1676157 4 179011288 [A/C] rs17756250 4 179012585 [A/G] rs533025 4 179023206 [A/G] rs672041 4 179032994 [A/G] rs553372 4 179046619 [A/G] rs11131851 4 179046640 [T/C] rs9993819 4 179055616 [T/C] rs604363 4 179067086 [A/G] rs493668 4 179069109 [A/G] rs664886 4 179071004 [T/C] rs1458719 4 179107663 [A/G] rs10017808 4 179110916 [A/C] rs1458717 4 179114110 [A/G] rs1545672 4 179119001 [A/G] rs13132202 4 179125887 [T/C] rs17758367 4 179135822 [A/G] rs10019549 4 179159462 [T/G] rs11131862 4 179172237 [T/C] rs2063396 4 179176878 [T/G] rs12650801 4 179184331 [T/C] rs6818908 4 179185906 [A/G] rs6552287 4 179194375 [T/C] rs4690620 4 179198970 [T/G] rs17708346 4 179199152 [A/G] rs12648022 4 179200338 [T/C] rs6552290 4 179208760 [A/G] rs1567475 4 179227598 [T/C] rs1567474 4 179227880 [A/G] rs925373 4 179247331 [T/C] rs6837438 4 179251931 [A/C] rs2666044 4 179266260 [T/C] rs1473016 4 179275567 [A/C] rs2063393 4 179277574 [T/C] rs3109075 4 179283569 [A/G] rs12643657 4 179286562 [A/G] rs2705988 4 179290393 [A/G] rs1022117 4 179299406 [T/C] rs1510631 4 179311419 [A/G] rs1473017 4 179323762 [A/C] rs17065950 4 179326362 [T/G] rs2263116 4 179334721 [T/C] rs9991342 4 179335261 [A/C] rs2715399 4 179337999 [T/G] rs1567477 4 179339480 [A/G] rs2666052 4 179340650 [T/G] rs2715402 4 179341460 [A/G] rs1606021 4 179346683 [T/C] rs2666062 4 179350247 [A/G] rs10520407 4 179356991 [T/C] rs2705977 4 179359572 [T/C] rs6819722 4 179362277 [A/G] rs2706018 4 179363159 [T/C] rs2702386 4 179365152 [A/G] rs736591 4 179374122 [A/G] rs2702383 4 179378497 [A/G] rs11944902 4 179380391 [A/G] rs11940603 4 179380432 [T/C] rs1903524 4 179380467 [A/G] rs2702385 4 179383805 [A/G] rs2256732 4 179385177 [T/C] rs13120364 4 179385208 [A/C] rs10471172 4 179385447 [T/C] rs10471173 4 179385635 [T/C] rs2249887 4 179387496 [A/G] rs2126272 4 179387659 [T/C] rs2126273 4 179387786 [T/C] rs2614609 4 179388852 [T/C] rs12501890 4 179389332 [A/C] rs12501924 4 179389470 [T/C] rs2715373 4 179390635 [T/G] rs2250361 4 179391633 [A/G] rs6840687 4 179392878 [T/G] rs7696617 4 179395117 [A/G] rs17713627 4 179395250 [T/C] rs2702452 4 179396545 [T/C] rs17066149 4 179397107 [T/C] rs1870793 4 179398668 [T/G] rs2702414 4 179399523 [A/G] rs2702449 4 179401433 [A/G] rs2702450 4 179401563 [T/C] rs7435595 4 179402198 [A/G] rs2614589 4 179402364 [T/C] rs1903530 4 179402816 [T/G] rs2465532 4 179404023 [A/G] rs1903532 4 179407255 [A/C] rs2715388 4 179408291 [T/C] rs7677592 4 179409526 [A/G] rs1903535 4 179410247 [T/C] rs1903536 4 179410273 [T/C] rs7669485 4 179420957 [A/G] rs2702432 4 179423869 [T/G] rs2702431 4 179424481 [T/C] rs2702430 4 179426861 [A/G] rs13140529 4 179442000 [T/C] rs998257 4 179447164 [T/C] rs2715500 4 179448086 [T/C] rs13146234 4 179451516 [T/C] rs2614633 4 179454416 [A/G] rs2169394 4 179458843 [T/C] rs2246528 4 179466683 [T/G] rs2614651 4 179467290 [A/G] rs17066329 4 179471262 [T/C] rs1903558 4 179475641 [T/C] rs1903557 4 179477407 [A/G] rs13108016 4 179479829 [T/C] rs1903552 4 179481211 [A/G] rs1903551 4 179481298 [A/G] rs2702464 4 179481522 [A/G] rs3108797 4 179482210 [A/G] rs4861888 4 179486578 [A/G] rs6811144 4 179488838 [A/G] rs2378847 4 179491966 [A/G] rs880240 4 179492948 [T/G] rs11938913 4 179493366 [T/C] rs2715544 4 179493721 [A/G] rs11942861 4 179496461 [A/G] rs2614555 4 179498010 [T/C] rs2126270 4 179503140 [A/G] rs9992214 4 179505850 [A/C] rs2715518 4 179511788 [A/G] rs2715520 4 179514388 [A/G] rs4394037 4 179516915 [A/G] rs10866225 4 179520686 [T/C] rs4607266 4 179521436 [T/C] rs4541553 4 179525874 [A/G] rs1434035 4 179530781 [T/C] rs4993972 4 179534988 [T/C] rs1036313 4 179535767 [A/C] rs17066480 4 179535956 [A/C] rs17066485 4 179536869 [A/G] rs17066498 4 179537855 [T/G] rs12331446 4 179538235 [T/C] rs5012200 4 179539753 [T/C] rs2715490 4 179541008 [T/C] rs2715491 4 179541036 [A/G] rs2715493 4 179541387 [A/G] rs17066521 4 179544637 [A/G] rs17066523 4 179544731 [T/G] rs12644125 4 179545940 [T/C] rs2890028 4 179547537 [A/C] rs2570725 4 179549418 [T/C] rs10434287 4 179549653 [A/G] rs4484343 4 179550103 [T/C] rs7661561 4 179550271 [A/G] rs12498819 4 179557134 [T/C] rs1583358 4 179563805 [A/G] rs1897760 4 179564248 [T/C] rs1434046 4 179573368 [A/G] rs10007324 4 179576074 [A/G] rs2570731 4 179584676 [T/C] rs10014516 4 179594357 [A/G] rs346101 4 179604212 [A/G] rs118806 4 179609480 [A/G] rs427796 4 179612525 [A/C] rs4862035 4 179614998 [A/G] rs17066635 4 179615916 [A/G] rs379519 4 179619524 [A/G] rs390455 4 179620557 [A/C] rs17066644 4 179620725 [T/G] rs423481 4 179625163 [T/C] rs10520412 4 179627762 [A/C] rs17731793 4 179629091 [A/G] rs2122136 4 179629221 [A/G] rs7666980 4 179633509 [A/G] rs17066688 4 179640780 [T/G] rs4861516 4 179661007 [A/G] rs346116 4 179662868 [A/G] rs418063 4 179665370 [A/G] rs377641 4 179665417 [T/C] rs17732937 4 179677801 [T/G] rs12647667 4 179678752 [T/C] rs4862126 4 179681882 [T/G] rs346119 4 179683403 [T/C] rs346127 4 179687948 [A/G] rs1448958 4 179692090 [T/C] rs4862146 4 179696460 [T/C] rs4862147 4 179698359 [A/G] rs7679972 4 179699093 [T/C] rs895873 4 179700959 [T/G] rs12508820 4 179702044 [A/G] rs11937114 4 179704645 [T/G] rs12504394 4 179704824 [A/G] rs1947202 4 179705308 [A/G] rs1448954 4 179724943 [T/C] rs4862165 4 179729425 [A/C] rs6843842 4 179750895 [T/C] rs7684851 4 179759509 [A/G] rs2166984 4 179760962 [T/C] rs4861574 4 179769492 [A/G] rs1348365 4 179802170 [A/C] rs9312236 4 179825640 [T/C] rs12502810 4 179833516 [A/G] rs6847330 4 179837718 [A/G] rs1373044 4 179849372 [T/C] rs11733087 4 179865606 [T/C] rs11929794 4 179872123 [A/C] rs10014264 4 179894901 [A/G] rs9998128 4 179896707 [A/G] rs10033034 4 179899458 [A/G] rs1348368 4 179899843 [A/G] rs10005809 4 179900768 [T/C] rs930972 4 179917392 [A/G] rs2044868 4 179921499 [A/G] rs7689898 4 179925680 [T/C] rs9995115 4 179926087 [A/C] rs17736809 4 179929126 [A/G] rs6833369 4 179929454 [A/C] rs13144575 4 179932194 [T/C] rs7687736 4 179937829 [A/C] rs6841573 4 179938777 [T/C] rs13137879 4 179940301 [T/G] rs2167373 4 179942389 [T/G] rs17799333 4 179944405 [T/G] rs7698185 4 179944540 [A/C] rs17066974 4 179947803 [T/C] rs7694613 4 179961720 [A/G] rs9312239 4 179962359 [T/G] rs17067013 4 179963088 [A/C] rs10009907 4 179965986 [A/C] rs1823603 4 179973430 [T/C] rs11736034 4 179974064 [T/G] rs1542280 4 179977587 [A/G] rs7671216 4 179983413 [T/C] rs12499500 4 179989221 [A/G] rs10520417 4 179992133 [A/G] rs1993095 4 180000268 [A/G] rs11724611 4 180002879 [T/C] rs17801260 4 180005125 [A/G] rs11734391 4 180012674 [T/C] rs13105244 4 180013203 [A/C] rs11131908 4 180014056 [T/G] rs1451407 4 180014143 [T/G] rs17067096 4 180014954 [A/G] rs1975651 4 180024042 [A/G] rs2197086 4 180032069 [T/C] rs7699104 4 180032926 [A/C] rs13126556 4 180036877 [T/C] rs2028492 4 180039967 [T/C] rs17067100 4 180040368 [T/C] rs17801853 4 180045846 [A/G] rs10004699 4 180047257 [A/G] rs17067123 4 180048362 [T/C] rs12643053 4 180051555 [A/C] rs13145669 4 180053797 [T/C] rs17067153 4 180055500 [A/G] rs1451420 4 180056687 [A/G] rs10011636 4 180063431 [T/C] rs1036767 4 180068417 [A/G] rs1016186 4 180072512 [A/G] rs1016184 4 180072951 [A/G] rs11939017 4 180085436 [A/G] rs17067173 4 180085873 [A/C] rs2383273 4 180095990 [T/G] rs7671333 4 180106072 [A/G] rs4862780 4 180109258 [A/G] rs17746595 4 180116455 [A/G] rs11934681 4 180121844 [A/G] rs1350327 4 180126785 [A/G] rs1379410 4 180131863 [A/G] rs1457402 4 180133742 [T/C] rs9991397 4 180137681 [A/G] rs4621480 4 180137800 [T/C] rs17803697 4 180147019 [T/C] rs2383278 4 180148587 [A/G] rs2383279 4 180148617 [T/C] rs10015629 4 180149016 [T/C] rs4146838 4 180151019 [T/G] rs12641267 4 180157413 [A/G] rs17747864 4 180165656 [T/G] rs10000174 4 180168625 [A/C] rs7682192 4 180173268 [A/C] rs13108774 4 180173785 [A/C] rs11131921 4 180179576 [T/C] rs10005160 4 180182483 [A/G] rs17067290 4 180186551 [A/G] rs6850582 4 180187024 [T/C] rs1457413 4 180188121 [A/G] rs10007980 4 180193895 [A/G] rs6828433 4 180193914 [A/G] rs6812195 4 180203808 [A/G] rs7670049 4 180206478 [A/G] rs10010601 4 180207412 [T/C] rs11943704 4 180207805 [T/C] rs7667180 4 180211211 [A/C] rs10434252 4 180230319 [T/C] rs13136851 4 180240950 [A/G] rs17067359 4 180241033 [A/G] rs1455689 4 180246936 [T/G] rs6552356 4 180248838 [A/G] rs17817727 4 180250564 [T/C] rs13146351 4 180250778 [T/G] rs17067392 4 180250837 [T/G] rs921839 4 180251982 [T/C] rs7665006 4 180253471 [A/G] rs6826259 4 180257370 [T/C] rs7654367 4 180263649 [A/G] rs1017671 4 180267949 [T/C] rs11933503 4 180269114 [T/C] rs12511057 4 180271128 [A/G] rs10019140 4 180275389 [A/G] rs1455681 4 180275433 [A/G] rs17768364 4 180279328 [T/C] rs17067488 4 180280410 [A/G] rs980165 4 180282887 [T/C] rs6828941 4 180284473 [A/G] rs6811542 4 180284798 [T/C] rs1455699 4 180285200 [A/C] rs10032019 4 180291239 [T/G] rs13118455 4 180291324 [A/G] rs4861773 4 180293616 [A/G] rs17090630 4 180298293 [A/G] rs1378554 4 180302451 [T/C] rs10002760 4 180305067 [T/C] rs1455698 4 180306130 [T/C] rs6812281 4 180312809 [T/G] rs6841508 4 180313511 [A/G] rs4861775 4 180316651 [A/C] rs6841214 4 180319376 [A/G] rs7688643 4 180319752 [T/C] rs12508123 4 180320695 [T/C] rs17090633 4 180324614 [T/G] rs6837023 4 180330521 [A/G] rs9312251 4 180332717 [A/C] rs13122924 4 180334106 [A/G] rs1401916 4 180334183 [A/G] rs1378547 4 180335990 [T/C] rs10009088 4 180336832 [A/G] rs1455659 4 180337114 [A/C] rs10031494 4 180337189 [A/C] rs11939068 4 180339842 [T/C] rs1455661 4 180344099 [T/C] rs4861401 4 180347106 [A/G] rs7658508 4 180347365 [A/G] rs17821431 4 180348448 [T/C] rs6552362 4 180351563 [A/G] rs4861781 4 180352288 [A/G] rs1378552 4 180356846 [T/C] rs2605047 4 180361361 [T/G] rs2605050 4 180362145 [A/G] rs12643739 4 180365721 [A/G] rs17770817 4 180365895 [T/G] rs2716816 4 180383312 [T/C] rs767002 4 180387187 [T/G] rs13107405 4 180389661 [T/C] rs6823606 4 180393970 [A/G] rs6826419 4 180412136 [T/C] rs9991285 4 180414351 [A/G] rs1455693 4 180417262 [A/G] rs2254490 4 180418475 [T/G] rs13129106 4 180419383 [T/C] rs2605070 4 180420134 [T/G] rs2681358 4 180433430 [T/C] rs2681357 4 180436364 [T/C] rs1464292 4 180442301 [A/G] rs4861784 4 180446118 [T/C] rs10017041 4 180466309 [T/C] rs10005349 4 180466423 [A/G] rs6852751 4 180466511 [T/C] rs2584396 4 180467353 [T/G] rs3911604 4 180467437 [A/G] rs3907136 4 180472146 [T/G] rs3911610 4 180472174 [T/C] rs2716771 4 180472339 [A/G] rs2716772 4 180472353 [A/C] rs17067795 4 180476903 [T/C] rs3911612 4 180493646 [A/G] rs2333688 4 180497015 [T/G] rs2716785 4 180498452 [T/C] rs2333689 4 180499234 [T/G] rs2584414 4 180500797 [T/C] rs2611020 4 180501487 [A/G] rs6552374 4 180504324 [T/C] rs2920105 4 180505632 [T/C] rs2716798 4 180509267 [T/G] rs2716799 4 180509927 [T/G] rs2716800 4 180510815 [A/G] rs2611035 4 180512146 [A/C] rs2584430 4 180512607 [T/G] rs10009213 4 180512644 [T/G] rs3902658 4 180514510 [T/C] rs3907138 4 180516403 [A/G] rs2584434 4 180518801 [T/C] rs2716805 4 180519077 [T/C] rs4345226 4 180521957 [A/G] rs2584437 4 180522174 [A/G] rs6827730 4 180524520 [A/G] rs17831521 4 180528017 [A/G] rs2611043 4 180528263 [A/C] rs6816822 4 180531692 [T/C] rs10520430 4 180536545 [T/G] rs17067866 4 180537212 [T/C] rs13146175 4 180537663 [A/G] rs3849602 4 180542136 [T/C] rs3849603 4 180542333 [T/C] rs3849606 4 180548076 [T/C] rs4526010 4 180551100 [T/C] rs6854193 4 180564205 [T/C] rs10520432 4 180564815 [T/C] rs7659991 4 180570932 [T/C] rs6836146 4 180579444 [A/C] rs12509486 4 180582498 [T/C] rs6840953 4 180586598 [T/C] rs10032248 4 180588881 [T/G] rs17067909 4 180589341 [T/C] rs2703825 4 180591326 [A/C] rs2584393 4 180591910 [A/G] rs3849612 4 180596542 [A/C] rs6552386 4 180608477 [T/C] rs982088 4 180608655 [A/G] rs12500438 4 180613345 [T/C] rs17498828 4 180615657 [A/G] rs1020237 4 180619408 [A/C] rs4861798 4 180624051 [A/G] rs4373197 4 180627328 [A/G] rs10084772 4 180635834 [T/C] rs6852457 4 180652005 [T/C] rs13122669 4 180652782 [A/C] rs12502245 4 180659401 [A/C] rs17068069 4 180659403 [T/G] rs1380000 4 180661580 [T/G] rs10050025 4 180663940 [A/G] rs13113541 4 180664123 [T/C] rs17090640 4 180667647 [A/G] rs11724099 4 180668187 [T/G] rs10520433 4 180669418 [T/C] rs17746764 4 180671987 [T/C] rs6851499 4 180672548 [T/C] rs2100686 4 180673271 [A/G] rs11736914 4 180673823 [T/C] rs1903032 4 180678164 [A/G] rs13125519 4 180678226 [A/C] rs17068136 4 180683092 [T/C] rs17068139 4 180683418 [T/C] rs17068140 4 180683541 [A/G] rs17803891 4 180684491 [A/G] rs11131944 4 180687498 [A/G] rs6844851 4 180688000 [T/C] rs17747662 4 180693794 [T/G] rs7678609 4 180696728 [A/G] rs1017710 4 180700264 [T/C] rs12510224 4 180702862 [T/G] rs7674308 4 180704767 [T/C] rs11495908 4 180704918 [A/G] rs970588 4 180710395 [T/C] rs17068192 4 180711597 [T/C] rs10035040 4 180714806 [A/G] rs1903027 4 180715010 [T/C] rs17068194 4 180715058 [A/G] rs13115756 4 180716739 [A/G] rs9998237 4 180718982 [T/C] rs11729049 4 180719585 [A/G] rs1870350 4 180725001 [T/C] rs1379986 4 180743647 [T/C] rs6838358 4 180744856 [A/G] rs13101669 4 180745286 [T/C] rs17068207 4 180745339 [T/C] rs1458669 4 180747463 [A/G] rs1379983 4 180757043 [A/G] rs7685478 4 180758188 [T/C] rs6552396 4 180764869 [A/C] rs10520438 4 180764928 [A/G] rs17068232 4 180770819 [A/G] rs986247 4 180772704 [T/C] rs6832008 4 180774423 [A/G] rs13435610 4 180787794 [T/G] rs12651279 4 180790098 [A/G] rs922031 4 180791236 [A/C] rs17068292 4 180794840 [T/C] rs7654672 4 180798886 [A/C] rs7655189 4 180798964 [A/G] rs10520440 4 180799005 [T/G] rs6826314 4 180801466 [A/G] rs17068316 4 180802030 [A/C] rs1072776 4 180803490 [T/C] rs1458664 4 180818705 [T/C] rs6552399 4 180819627 [T/C] rs17068350 4 180819809 [A/G] rs1947622 4 180822313 [A/C] rs11934076 4 180823827 [T/C] rs1870347 4 180824638 [A/G] rs6820592 4 180825044 [A/G] rs1545671 4 180834630 [T/C] rs12512992 4 180844991 [T/C] rs13112173 4 180846512 [A/G] rs977860 4 180849794 [T/C] rs10780062 4 180856616 [A/G] rs9991082 4 180857874 [A/G] rs1458656 4 180859131 [A/G] rs10000486 4 180859149 [A/G] rs17068418 4 180862232 [T/C] rs2125431 4 180867238 [A/G] rs6836502 4 180875233 [A/C] rs7675742 4 180877617 [T/C] rs1814673 4 180878172 [A/G] rs4861822 4 180880956 [A/G] rs6810891 4 180893766 [A/C] rs12510169 4 180894794 [A/G] rs7674405 4 180896929 [A/C] rs1994813 4 180899782 [A/C] rs17068502 4 180901257 [A/G] rs6836406 4 180902914 [A/G] rs4861824 4 180903852 [A/G] rs13111060 4 180909740 [A/G] rs17068534 4 180911019 [A/G] rs6552405 4 180911596 [T/C] rs9991368 4 180915780 [A/C] rs9991928 4 180916219 [T/G] rs6858037 4 180920056 [T/C] rs4861826 4 180920998 [A/C] rs10019132 4 180922702 [A/G] rs13123422 4 180923802 [T/C] rs7698405 4 180926735 [T/G] rs6835516 4 180929339 [T/C] rs6552407 4 180929612 [A/G] rs4241716 4 180931381 [T/C] rs2309139 4 180933174 [A/G] rs6837073 4 180933347 [A/C] rs4521383 4 180934921 [A/G] rs13114766 4 180935476 [T/C] rs2871129 4 180942234 [A/G] rs1316917 4 180942572 [T/C] rs4254817 4 180942678 [T/C] rs10013059 4 180951070 [A/G] rs2309129 4 180953886 [A/C] rs13327938 4 180954083 [T/C] rs17771724 4 180955602 [A/G] rs2309124 4 180958428 [A/C] rs1112857 4 180959787 [T/C] rs6829907 4 180962074 [T/G] rs1994816 4 180968431 [A/G] rs1665841 4 180982097 [T/C] rs7690743 4 180988794 [T/C] rs7680285 4 180991444 [A/G] rs1665831 4 180998616 [T/C] rs1689004 4 181008167 [T/C] rs6830355 4 181011016 [T/C] rs12499924 4 181022656 [T/C] rs7656301 4 181027678 [T/G] rs7679909 4 181028368 [A/G] rs7697007 4 181028790 [A/G] rs720778 4 181031805 [A/G] rs13148326 4 181032789 [A/G] rs1979068 4 181035645 [A/G] rs1689020 4 181038957 [A/C] rs1665844 4 181039757 [A/C] rs1689015 4 181042988 [T/C] rs13146117 4 181045298 [A/C] rs9990459 4 181046018 [T/C] rs1689014 4 181046865 [A/G] rs13135628 4 181048589 [T/C] rs1665851 4 181048849 [A/G] rs10520442 4 181051943 [A/C] rs1689021 4 181056626 [A/C] rs1447317 4 181066033 [T/G] rs1447320 4 181075687 [T/C] rs13129209 4 181076187 [T/C] rs11131975 4 181080486 [T/C] rs13121605 4 181084084 [A/G] rs17068788 4 181088534 [A/G] rs12642635 4 181095016 [A/G] rs7677721 4 181098462 [A/G] rs1900567 4 181101157 [A/G] rs17068825 4 181101509 [A/G] rs2166701 4 181102208 [A/G] rs6836062 4 181108510 [A/G] rs10027059 4 181118760 [A/G] rs17068866 4 181119137 [T/C] rs1868056 4 181124250 [A/C] rs6855724 4 181124269 [T/C] rs11734697 4 181125964 [A/G] rs10007350 4 181126498 [A/G] rs9312259 4 181126541 [A/G] rs1447325 4 181136629 [A/C] rs7655191 4 181137134 [A/G] rs17068948 4 181137418 [T/C] rs2053745 4 181138753 [A/G] rs17068958 4 181139421 [T/C] rs7663206 4 181148678 [T/C] rs1447323 4 181152554 [A/G] rs17068995 4 181152961 [T/C] rs10020349 4 181153885 [A/G] rs7697719 4 181154351 [A/G] rs4861844 4 181157746 [T/C] rs10520443 4 181158380 [A/G] rs17069022 4 181161490 [A/G] rs11734278 4 181167766 [A/G] rs17069038 4 181169328 [A/C] rs34136869 4 181181237 [A/G] rs11131981 4 181186334 [T/C] rs7667016 4 181193110 [T/G] rs17069051 4 181196155 [T/G] rs10018538 4 181205991 [T/C] rs17777325 4 181207294 [T/C] rs17069068 4 181210711 [T/C] rs7696117 4 181211523 [A/G] rs17069075 4 181214528 [A/C] rs7671393 4 181215239 [A/G] rs6834475 4 181215806 [A/G] rs12501188 4 181221012 [T/C] rs17069124 4 181221342 [T/C] rs13109268 4 181222881 [T/C] rs17069165 4 181224923 [T/G] rs17834570 4 181225219 [A/C] rs13130442 4 181225524 [T/C] rs17069175 4 181226698 [A/G] rs4991519 4 181227321 [A/G] rs10866234 4 181231080 [A/G] rs13106873 4 181235156 [A/G] rs2871184 4 181239345 [T/C] rs13150189 4 181239467 [A/G] rs4290930 4 181239651 [A/G] rs13105027 4 181240076 [A/G] rs6839892 4 181243214 [T/G] rs17069214 4 181247001 [T/C] rs6847807 4 181247685 [A/G] rs2309330 4 181251312 [A/G] rs6552415 4 181253016 [A/G] rs7688867 4 181253362 [T/C] rs4861849 4 181259377 [T/C] rs6830593 4 181263217 [A/G] rs11723234 4 181265740 [A/G] rs13113937 4 181266001 [T/C] rs17779404 4 181271289 [T/G] rs2309337 4 181271864 [T/G] rs17069255 4 181272381 [A/G] rs4241719 4 181273127 [T/C] rs13141204 4 181275147 [A/C] rs10520445 4 181276302 [T/C] rs2309249 4 181288170 [T/C] rs13136634 4 181289806 [A/C] rs7667245 4 181290296 [A/G] rs4560455 4 181292279 [A/G] rs28627320 4 181294474 [A/C] rs7699693 4 181295223 [A/C] rs11934651 4 181295874 [A/C] rs12649854 4 181297475 [A/G] rs2309241 4 181301107 [A/G] rs10032868 4 181303512 [A/G] rs10020466 4 181306647 [A/G] rs10013756 4 181310122 [A/G] rs10780063 4 181310204 [A/G] rs4437296 4 181310570 [T/C] rs6811892 4 181312837 [A/G] rs11734423 4 181313921 [T/C] rs4473690 4 181315369 [T/G] rs6858814 4 181316366 [T/C] rs6833224 4 181316450 [T/C] rs7659432 4 181318838 [A/G] rs17069334 4 181321511 [T/C] rs13127344 4 181321999 [T/C] rs17069342 4 181327110 [T/G] rs2309244 4 181327429 [T/C] rs2309246 4 181327662 [T/C] rs2871159 4 181328600 [T/C] rs6552422 4 181329037 [T/C] rs11936982 4 181333249 [A/G] rs12509071 4 181342591 [T/C] rs2677008 4 181343571 [T/C] rs9990567 4 181346824 [A/G] rs17793705 4 181347530 [A/G] rs1320084 4 181350463 [A/C] rs1320083 4 181350614 [T/C] rs2677005 4 181351303 [T/C] rs7678786 4 181351635 [T/C] rs2309341 4 181353732 [A/G] rs4597870 4 181353789 [T/C] rs4241721 4 181356882 [T/C] rs17069404 4 181358136 [A/G] rs17794036 4 181358718 [A/C] rs2727427 4 181361148 [T/C] rs13127074 4 181361180 [A/G] rs4552520 4 181366289 [T/C] rs2546589 4 181368684 [A/G] rs2546588 4 181370064 [A/G] rs7674341 4 181375630 [A/G] rs2727438 4 181380227 [A/C] rs2546581 4 181382631 [A/C] rs2727439 4 181386404 [A/C] rs17069436 4 181399345 [A/G] rs2727444 4 181401306 [A/C] rs2546575 4 181405666 [A/G] rs7687661 4 181411378 [A/G] rs2546571 4 181421221 [T/C] rs2546614 4 181426359 [A/G] rs2546606 4 181437203 [A/C] rs6829918 4 181438804 [A/G] rs2546595 4 181440620 [T/G] rs6843673 4 181440776 [T/C] rs6845332 4 181441363 [A/G] rs2059117 4 181441802 [T/G] rs2059116 4 181441904 [T/C] rs13134793 4 181448254 [T/C] rs11943526 4 181449355 [A/G] rs3113753 4 181450318 [T/G] rs1422738 4 181450417 [T/C] rs17069618 4 181451934 [A/G] rs17180827 4 181454233 [A/G] rs17795466 4 181456588 [T/C] rs6853596 4 181460127 [A/G] rs9684754 4 181461281 [T/C] rs7662339 4 181462101 [A/G] rs12502732 4 181462408 [T/C] rs7669248 4 181463189 [T/G] rs7669469 4 181463308 [A/G] rs17069681 4 181468667 [A/G] rs3095972 4 181468882 [A/C] rs3095971 4 181468920 [A/G] rs998760 4 181469160 [A/G] rs3113741 4 181470273 [T/C] rs6851088 4 181471913 [A/G] rs12331673 4 181472405 [T/C] rs11943826 4 181474231 [A/G] rs17796537 4 181474291 [T/C] rs17069754 4 181476452 [T/C] rs1422506 4 181476804 [A/G] rs1559103 4 181479147 [A/G] rs17069770 4 181479706 [A/G] rs1030188 4 181479865 [A/G] rs13134598 4 181480238 [A/G] rs17796970 4 181485416 [A/G] rs7656346 4 181489069 [A/G] rs3095968 4 181492183 [T/C] rs3113749 4 181492677 [T/G] rs6552431 4 181493355 [A/G] rs6846354 4 181493608 [A/G] rs749463 4 181494406 [T/C] rs13114558 4 181497819 [T/C] rs7669125 4 181498188 [T/C] rs6851035 4 181499684 [T/C] rs6857566 4 181500662 [A/G] rs3095966 4 181501862 [A/G] rs1422505 4 181504039 [T/C] rs1035423 4 181518101 [T/C] rs3113752 4 181519492 [A/G] rs3113757 4 181520702 [A/G] rs17798302 4 181529714 [T/G] rs17069887 4 181533003 [A/C] rs3113765 4 181535808 [A/G] rs2059096 4 181536607 [T/C] rs2309360 4 181539774 [A/G] rs3113773 4 181540757 [A/G] rs2446802 4 181546303 [A/G] rs10000265 4 181555711 [A/G] rs2546286 4 181559236 [T/C] rs6823471 4 181563204 [A/G] rs2613041 4 181563321 [T/C] rs2546275 4 181567271 [A/G] rs4861441 4 181571062 [T/C] rs2613047 4 181571097 [A/C] rs1422513 4 181571542 [A/G] rs17069934 4 181571618 [T/C] rs10032205 4 181572734 [T/C] rs2546267 4 181572822 [T/C] rs1422511 4 181574201 [T/C] rs2613055 4 181576122 [A/G] rs10049679 4 181576712 [T/G] rs2194101 4 181577045 [A/G] rs2112580 4 181577800 [T/C] rs13114018 4 181580617 [T/C] rs17069961 4 181582856 [T/C] rs2546262 4 181582986 [A/G] rs11132009 4 181583727 [T/C] rs2546260 4 181584314 [A/G] rs1422509 4 181585352 [A/G] rs17806047 4 181591556 [A/G] rs2613072 4 181598141 [A/G] rs11132010 4 181600151 [T/C] rs2546245 4 181603477 [A/G] rs2161326 4 181608225 [A/G] rs7667149 4 181608833 [A/G] rs2216624 4 181612806 [T/C] rs11132014 4 181626744 [T/G] rs2545255 4 181629090 [T/C] rs1363207 4 181636440 [T/C] rs2545308 4 181637915 [A/G] rs6853667 4 181637973 [A/C] rs6552438 4 181638467 [A/G] rs17807368 4 181639976 [A/G] rs17070051 4 181640911 [T/C] rs11934851 4 181644985 [T/C] rs1421998 4 181647206 [A/G] rs2545288 4 181648742 [A/G] rs12643977 4 181663616 [A/C] rs11734848 4 181680688 [A/C] rs2613007 4 181682943 [A/G] rs918402 4 181691738 [A/C] rs3101265 4 181699644 [A/G] rs2024530 4 181707386 [A/G] rs2545306 4 181720229 [A/G] rs2250756 4 181720516 [A/G] rs2613029 4 181727899 [A/G] rs2613032 4 181729352 [A/G] rs7693824 4 181730895 [T/C] rs10031426 4 181734569 [A/G] rs4861444 4 181734640 [A/G] rs17070118 4 181748551 [T/C] rs17203326 4 181752254 [A/G] rs10746544 4 181754567 [T/C] rs10866239 4 181756792 [A/G] rs7657018 4 181757422 [A/G] rs4306994 4 181758795 [A/G] rs12648100 4 181782574 [T/C] rs12644875 4 181782616 [T/C] rs6832395 4 181782692 [A/G] rs17070257 4 181783984 [T/C] rs11722768 4 181785074 [A/G] rs6854060 4 181785938 [T/G] rs6854130 4 181786172 [A/C] rs7694302 4 181796228 [A/G] rs7659727 4 181797596 [A/G] rs7692001 4 181801052 [A/G] rs6850503 4 181808235 [A/G] rs10866240 4 181810029 [A/C] rs13122971 4 181810622 [T/C] rs17070275 4 181813489 [T/G] rs12504749 4 181814242 [T/C] rs2309396 4 181814803 [A/G] rs6813148 4 181814917 [A/G] rs1589580 4 181821983 [T/C] rs1533873 4 181825165 [A/G] rs12507955 4 181826016 [A/G] rs4861884 4 181826838 [A/C] rs17070332 4 181834100 [A/G] rs17070354 4 181850257 [T/C] rs10015408 4 181851323 [T/C] rs17070369 4 181861300 [T/C] rs10866243 4 181867512 [T/C] rs6820051 4 181868940 [A/G] rs13115400 4 181885905 [A/G] rs10018261 4 181888903 [A/G] rs11727972 4 181892753 [A/G] rs11931741 4 181895905 [A/G] rs13435468 4 181898870 [T/G] rs7688750 4 181904385 [T/G] rs2056490 4 181905572 [A/G] rs10016729 4 181907769 [A/G] rs1916109 4 181910926 [A/C] rs1969399 4 181912806 [A/G] rs6858275 4 181914603 [A/G] rs6817295 4 181915930 [A/G] rs11132035 4 181919047 [A/C] rs11942320 4 181920297 [A/G] rs11132037 4 181920483 [A/G] rs13353673 4 181923958 [T/C] rs6843038 4 181925065 [T/C] rs11946898 4 181926518 [T/G] rs11132039 4 181927704 [T/G] rs10022243 4 181928515 [T/C] rs17070458 4 181929211 [A/G] rs12647680 4 181931789 [T/G] rs12648536 4 181932885 [T/C] rs12642493 4 181933056 [A/G] rs7663613 4 181934106 [A/G] rs1357353 4 181935405 [A/G] rs17070467 4 181941847 [A/G] rs17070468 4 181942406 [A/C] rs9997006 4 181944160 [T/G] rs7659915 4 181945777 [A/G] rs13121678 4 181957456 [A/G] rs13120104 4 181979722 [T/C] rs10019828 4 181982520 [T/G] rs6856731 4 181987292 [A/C] NR_033918 LINC00290 Silent rs12645608 4 182007048 [A/C] NR_033918 LINC00290 Silent rs7659755 4 182009132 [A/G] NR_033918 LINC00290 Silent rs9312270 4 182024045 [A/G] NR_033918 LINC00290 Silent rs11132044 4 182029163 [A/G] NR_033918 LINC00290 Silent rs13117129 4 182032424 [T/C] NR_033918 LINC00290 Silent rs4861905 4 182033941 [T/G] NR_033918 LINC00290 Silent rs7435210 4 182046294 [A/G] NR_033918 LINC00290 Silent rs10020564 4 182048302 [T/C] NR_033918 LINC00290 Silent rs7440625 4 182048692 [A/G] NR_033918 LINC00290 Silent rs4488971 4 182053380 [A/G] NR_033918 LINC00290 Silent rs998399 4 182054829 [T/C] NR_033918 LINC00290 Silent rs6852438 4 182061996 [T/C] NR_033918 LINC00290 Silent rs4861466 4 182064722 [A/G] NR_033918 LINC00290 Silent rs6824538 4 182065258 [A/G] NR_033918 LINC00290 Silent rs6825217 4 182065314 [A/G] NR_033918 LINC00290 Silent rs4349637 4 182065498 [A/C] NR_033918 LINC00290 Silent rs12650765 4 182065770 [A/G] NR_033918 LINC00290 Silent rs6552486 4 182066869 [A/G] NR_033918 LINC00290 Silent rs12498222 4 182067359 [A/G] NR_033918 LINC00290 Silent rs6552487 4 182068097 [T/C] NR_033918 LINC00290 Silent rs17070655 4 182068819 [A/G] NR_033918 LINC00290 Silent rs6828131 4 182070568 [A/C] NR_033918 LINC00290 Silent rs10520466 4 182072085 [T/C] NR_033918 LINC00290 Silent rs10520467 4 182072142 [A/G] NR_033918 LINC00290 Silent rs12503294 4 182077475 [T/G] NR_033918 LINC00290 Silent rs12507155 4 182078896 [A/C] NR_033918 LINC00290 Silent rs7688965 4 182089409 [A/G] rs12504486 4 182090083 [T/G] rs6844876 4 182092437 [T/G] rs1993327 4 182094811 [A/G] rs17828403 4 182095358 [T/G] rs4861919 4 182098564 [A/G] rs17232135 4 182101091 [T/G] rs10018288 4 182101689 [A/G] rs17828571 4 182101765 [A/G] rs9991738 4 182104055 [T/C] rs4422449 4 182105473 [A/C] rs17070731 4 182110328 [A/G] rs1454711 4 182111358 [A/G] rs1902112 4 182117057 [T/C] rs6845037 4 182118509 [T/C] rs9999847 4 182120631 [T/C] rs5019445 4 182126122 [A/G] rs9995325 4 182131530 [A/G] rs10520469 4 182133522 [A/G] rs1869606 4 182135395 [T/G] rs4861926 4 182136694 [T/G] rs6836317 4 182137188 [A/G] rs9994253 4 182140400 [T/C] rs4861928 4 182153124 [A/G] rs17070824 4 182154578 [A/G] rs10012888 4 182155026 [T/C] rs9999734 4 182157912 [A/G] rs6810865 4 182158275 [A/G] rs17070835 4 182159150 [A/G] rs4861929 4 182164515 [T/C] rs9992143 4 182167822 [T/C] rs17070839 4 182170424 [A/G] rs17240040 4 182171041 [T/C] rs7669856 4 182178058 [A/G] rs2034775 4 182178122 [T/C] rs11727860 4 182179570 [T/C] rs17070889 4 182179788 [A/G] rs7438836 4 182181119 [T/C] rs6849417 4 182182652 [T/C] NR_149139 LINC02500 EXON Silent rs10520473 4 182183915 [A/G] NR_149139 LINC02500 Silent rs17070908 4 182185835 [A/G] NR_149139 LINC02500 Silent rs6844811 4 182185950 [A/G] NR_149139 LINC02500 Silent rs1031500 4 182187373 [A/G] rs17240768 4 182189284 [T/G] rs7666029 4 182192995 [T/C] rs11930417 4 182195518 [A/C] rs1454694 4 182197947 [T/C] rs1563213 4 182199391 [A/G] rs1031501 4 182199523 [A/G] rs17070953 4 182200609 [A/G] rs4861931 4 182204531 [A/G] rs4861938 4 182210944 [A/C] rs1454696 4 182211159 [T/C] rs7681232 4 182213030 [A/G] rs9996848 4 182214915 [A/C] rs6817589 4 182216904 [A/C] rs10018479 4 182218143 [T/G] rs17071008 4 182221687 [T/G] rs2309470 4 182222033 [T/C] rs2309467 4 182222287 [A/C] rs17183114 4 182222727 [T/G] rs11930570 4 182226071 [A/G] rs10027292 4 182226435 [T/C] rs17183352 4 182227059 [A/G] rs13121655 4 182228434 [A/G] rs10520475 4 182231482 [T/C] rs1115988 4 182234393 [A/G] rs17071059 4 182234443 [T/C] rs9994198 4 182235447 [T/C] rs17071066 4 182237515 [T/C] rs7654697 4 182239040 [A/G] rs1584937 4 182247565 [T/C] rs6552489 4 182249501 [A/G] rs1563219 4 182256121 [A/G] rs17071132 4 182259455 [T/G] rs11723033 4 182262320 [A/G] rs7675654 4 182266682 [A/G] rs7674604 4 182271880 [A/G] rs10520476 4 182274315 [A/G] rs11729166 4 182276030 [T/C] rs2309460 4 182278111 [A/G] rs1987162 4 182278636 [A/G] rs17071170 4 182279787 [A/G] rs12647115 4 182280205 [A/G] rs4861945 4 182280270 [T/C] rs17185924 4 182280855 [A/G] rs4621476 4 182280863 [T/C] rs17071183 4 182282929 [A/G] rs4283709 4 182283087 [A/G] rs4861947 4 182284224 [A/C] rs6829606 4 182284314 [A/C] rs7657136 4 182285215 [T/C] rs6836888 4 182285422 [T/C] rs17071211 4 182286222 [T/G] rs7692027 4 182287004 [A/G] rs6552495 4 182288767 [T/C] rs12641677 4 182290596 [A/G] rs7657701 4 182292032 [A/G] rs7682400 4 182292227 [T/C] rs10520479 4 182292713 [T/C] rs17071237 4 182294897 [T/G] rs6834709 4 182295274 [A/C] rs10520478 4 182295676 [T/C] rs13145131 4 182297666 [T/C] rs2309472 4 182300733 [A/G] rs4522908 4 182304873 [T/G] rs6838270 4 182307648 [A/G] rs4479746 4 182311928 [A/G] rs13129340 4 182317147 [T/G] rs1030790 4 182318445 [T/C] rs11132055 4 182322805 [T/G] rs17071292 4 182327465 [T/C] rs724658 4 182327838 [A/C] rs724657 4 182327868 [A/G] rs724659 4 182327943 [A/G] rs6857563 4 182329791 [T/G] rs6857599 4 182329856 [T/G] rs6552500 4 182342069 [T/C] rs1369480 4 182342334 [T/C] rs1369479 4 182342394 [A/G] rs7692661 4 182345272 [T/C] rs1897994 4 182346097 [T/C] rs4861475 4 182347670 [T/C] rs17195559 4 182347745 [A/G] rs13112319 4 182348386 [T/C] rs892862 4 182350247 [A/C] rs4549433 4 182350796 [T/C] rs17195902 4 182353549 [T/C] rs6827352 4 182354145 [A/C] rs6828912 4 182362615 [T/G] rs11723828 4 182363381 [A/C] rs17071491 4 182366956 [A/G] rs1991989 4 182367808 [A/G] rs10002388 4 182370185 [A/G] rs17071527 4 182371433 [T/C] rs4861960 4 182372333 [T/C] rs4861962 4 182374325 [T/C] rs1435499 4 182376357 [A/C] rs10027214 4 182377628 [A/C] rs1435501 4 182383645 [A/C] rs7676405 4 182384993 [A/G] rs7695194 4 182387603 [A/G] rs1991988 4 182391631 [T/C] rs1991987 4 182391672 [A/G] rs28437883 4 182391939 [A/G] rs12645810 4 182396195 [A/G] rs7687690 4 182396586 [T/G] rs17198106 4 182396724 [T/C] rs4861966 4 182397058 [A/G] rs4861967 4 182398593 [T/C] rs981847 4 182399556 [T/C] rs17251860 4 182403395 [A/G] rs1561000 4 182403824 [T/G] rs6822070 4 182405735 [A/G] rs17252128 4 182407529 [A/G] rs4861970 4 182407681 [T/G] rs12649512 4 182410954 [T/G] rs4861477 4 182411580 [A/C] rs10520489 4 182412992 [A/G] rs17199337 4 182413696 [A/G] rs4861973 4 182415937 [T/C] rs4861975 4 182416097 [A/C] rs10006195 4 182420303 [T/C] rs7654623 4 182421815 [A/C] rs7661191 4 182422900 [A/G] rs930308 4 182426033 [T/C] rs11731430 4 182429303 [T/C] rs920083 4 182431113 [A/G] rs13107304 4 182432295 [A/C] rs4861977 4 182433238 [A/G] rs10520484 4 182433814 [A/C] rs1435497 4 182434469 [T/C] rs17071683 4 182438604 [T/G] rs11939305 4 182444131 [A/G] rs974578 4 182447323 [T/C] rs1439276 4 182450706 [A/G] rs4861981 4 182453413 [T/C] rs1439274 4 182454357 [A/G] rs17071724 4 182458937 [T/C] rs12650613 4 182459990 [A/C] rs7680020 4 182461424 [T/C] rs7663547 4 182461858 [T/C] rs7697865 4 182463503 [T/C] rs9998972 4 182463971 [A/C] rs12331810 4 182464909 [A/G] rs10005266 4 182465917 [A/G] rs4861982 4 182466644 [T/G] rs11132072 4 182467304 [A/G] rs17071811 4 182467989 [A/G] rs11132079 4 182470191 [T/C] rs17071826 4 182470210 [T/C] rs11944460 4 182470792 [T/C] rs13140378 4 182471822 [A/G] rs4861482 4 182472171 [T/C] rs4362864 4 182472791 [T/C] rs13103500 4 182473726 [T/G] rs13103727 4 182473823 [A/G] rs11934219 4 182477095 [T/G] rs2043893 4 182477386 [A/G] rs1025758 4 182480385 [T/G] rs2309504 4 182482693 [T/C] rs7440035 4 182482973 [T/G] rs1439283 4 182484769 [T/C] rs6845687 4 182487135 [T/C] rs6845256 4 182490447 [T/C] rs6845276 4 182490475 [T/C] rs4861485 4 182493718 [A/G] rs12511842 4 182507266 [A/G] rs10520496 4 182514392 [A/G] rs6849949 4 182520502 [T/C] rs11132083 4 182522272 [A/C] rs17210704 4 182523766 [A/C] rs1439279 4 182528430 [A/G] rs9799857 4 182537718 [T/G] rs17071911 4 182538969 [T/C] rs17071912 4 182539137 [T/C] rs10002408 4 182543945 [T/C] rs11721527 4 182544354 [T/C] rs745704 4 182544544 [T/C] rs745705 4 182544594 [A/G] rs715745 4 182548076 [A/G] rs6815916 4 182553043 [A/G] rs17211911 4 182564825 [A/C] rs7662677 4 182565693 [A/G] rs1971822 4 182566129 [T/C] rs17212220 4 182569100 [T/C] rs17212276 4 182571325 [T/G] rs10520501 4 182572102 [T/G] rs11727308 4 182572180 [A/G] rs6552517 4 182576586 [T/C] rs4590086 4 182578680 [A/G] rs6856771 4 182581686 [T/C] rs7658791 4 182582942 [A/C] rs4861488 4 182584177 [A/G] rs1439272 4 182584331 [A/G] rs6835945 4 182585855 [T/C] rs1439273 4 182588504 [T/C] rs10471178 4 182589046 [T/C] rs13144599 4 182591864 [T/C] rs1439281 4 182592079 [T/G] rs17279486 4 182592541 [T/C] rs17279535 4 182592981 [T/C] rs13133342 4 182594449 [A/G] rs4861998 4 182594688 [T/C] rs17072040 4 182597939 [T/C] rs6847130 4 182598039 [A/G] rs1371215 4 182601609 [T/C] rs6844975 4 182602940 [A/G] rs7666018 4 182606762 [A/G] rs4527522 4 182611537 [T/C] rs12503151 4 182612164 [T/G] rs2309573 4 182614559 [T/G] rs17072125 4 182616401 [T/C] rs7689930 4 182621264 [A/G] rs17072140 4 182621558 [T/G] rs17280931 4 182622759 [T/C] rs10520505 4 182626599 [A/G] rs10520506 4 182626706 [A/G] rs4861491 4 182627579 [A/G] rs2309534 4 182631262 [A/G] rs17215232 4 182632276 [A/G] rs17281245 4 182635289 [T/C] rs13143181 4 182637590 [T/C] rs17215414 4 182639404 [A/G] rs12502114 4 182641214 [A/G] rs2309541 4 182643207 [A/G] rs13113072 4 182646450 [A/G] rs2309544 4 182648949 [T/C] rs2309545 4 182649354 [T/C] rs17072184 4 182655999 [T/C] rs11934518 4 182662286 [T/C] rs6855392 4 182669719 [T/C] rs6552521 4 182669892 [A/G] rs2309550 4 182673224 [A/G] rs7656889 4 182677604 [A/G] rs10520510 4 182686437 [T/C] rs10520509 4 182686491 [T/C] rs17072241 4 182689025 [A/G] rs17072249 4 182691071 [A/G] rs12508055 4 182692368 [A/G] rs12505558 4 182696987 [A/G] rs7659598 4 182699379 [A/G] rs6855088 4 182704551 [A/G] rs11733364 4 182710802 [A/G] rs10013118 4 182711326 [T/G] rs4241739 4 182712956 [A/G] rs4541554 4 182713919 [T/C] rs17072280 4 182714961 [A/G] rs4074866 4 182716439 [T/G] rs6552523 4 182720291 [T/C] rs7665942 4 182724616 [A/G] rs17072291 4 182724752 [A/G] rs6815030 4 182727134 [T/C] rs17283383 4 182727482 [A/C] rs4862004 4 182733126 [A/G] rs4333223 4 182733805 [A/G] rs10012329 4 182740613 [T/C] rs7687804 4 182742349 [T/C] NR_147188 TEMN3-AS1 Silent rs11728634 4 182744106 [A/C] NR_147188 TEMN3-AS1 Silent rs17217936 4 182744561 [T/C] NR_147188 TEMN3-AS1 Silent rs7681861 4 182744904 [A/C] NR_147188 TEMN3-AS1 Silent rs7434383 4 182747639 [A/G] NR_147188 TEMN3-AS1 Silent rs4862009 4 182748140 [A/G] NR_147188 TEMN3-AS1 Silent rs17072369 4 182748677 [T/C] NR_147188 TEMN3-AS1 Silent rs4458490 4 182749521 [T/C] NR_147188 TEMN3-AS1 Silent rs4519836 4 182749549 [T/G] NR_147188 TEMN3-AS1 Silent rs12505472 4 182749585 [T/C] NR_147188 TEMN3-AS1 Silent rs749752 4 182754966 [A/C] rs10001447 4 182756765 [T/C] rs2048917 4 182757120 [T/C] rs10461322 4 182764613 [T/G] rs12508245 4 182770248 [A/C] rs7679999 4 182770862 [T/C] rs11931121 4 182775986 [A/G] rs10016994 4 182776413 [T/C] rs7655087 4 182777782 [T/G] rs6838314 4 182780188 [A/G] rs1914369 4 182780568 [A/G] rs2063954 4 182781422 [A/G] rs10520515 4 182781950 [T/C] rs17072409 4 182782507 [A/C] rs6823165 4 182784916 [T/C] rs10018081 4 182792074 [A/C] rs965523 4 182794879 [A/G] rs1400625 4 182798961 [T/C] rs11724059 4 182805092 [A/G] rs12644818 4 182805286 [T/G] rs2138743 4 182817317 [T/C] rs1400624 4 182817468 [T/C] rs1517298 4 182821968 [A/G] rs2048914 4 182825247 [A/G] rs11930332 4 182827787 [T/C] rs17072509 4 182828390 [A/G] rs17286513 4 182830928 [T/C] rs6824345 4 182834128 [T/C] rs17072515 4 182835130 [A/G] rs2199118 4 182847338 [A/G] rs1458889 4 182854996 [T/C] rs6813301 4 182859352 [A/C] rs11945595 4 182860907 [T/C] rs763482 4 182863097 [A/G] rs9993255 4 182868840 [A/G] rs4861497 4 182879932 [A/C] rs11944284 4 182880942 [T/C] rs9685589 4 182884590 [A/G] rs13141696 4 182886016 [T/C] rs9992244 4 182888219 [T/G] rs2063956 4 182895078 [A/G] rs7676827 4 182911139 [T/C] rs17288133 4 182913820 [A/G] rs17072625 4 182914650 [A/G] rs11938148 4 182914694 [T/C] rs17222326 4 182916588 [T/C] rs7697411 4 182917804 [A/C] rs12503812 4 182918564 [A/G] rs11946900 4 182919753 [A/G] rs7667255 4 182921858 [T/C] rs2100696 4 182932076 [T/C] rs2100695 4 182932198 [A/G] rs12645487 4 182932763 [A/G] rs977361 4 182933601 [T/C] rs9799641 4 182937043 [T/C] rs6816160 4 182942414 [A/G] rs9993807 4 182951552 [A/G] rs10866251 4 182959299 [T/C] rs1979296 4 182959578 [A/C] rs17072678 4 182964412 [A/G] rs7693462 4 182965163 [A/G] rs898129 4 182970006 [T/C] rs10001867 4 182972106 [T/C] rs10866253 4 182973237 [T/C] rs6812990 4 182975220 [T/C] rs335074 4 182975418 [T/G] rs17072702 4 182976765 [T/C] rs17072710 4 182983862 [A/G] rs6812461 4 182983955 [A/G] rs6824246 4 182988669 [T/G] rs2597144 4 182988914 [T/C] rs17072729 4 182989346 [T/C] rs10520518 4 182990553 [T/C] rs2609554 4 182990909 [A/G] rs17072756 4 182995164 [T/C] rs10026007 4 182995319 [A/G] rs2597125 4 182996793 [T/G] rs17303659 4 182998238 [T/C] rs1868642 4 182998270 [T/C] rs1868641 4 182998326 [T/C] rs10024819 4 183000121 [T/G] rs17303841 4 183000252 [T/C] rs13135549 4 183000925 [T/C] rs6552541 4 183004954 [A/G] rs17072794 4 183006470 [T/C] rs11132111 4 183007676 [A/G] rs2034975 4 183007922 [A/G] rs6839797 4 183008572 [T/C] rs6840333 4 183008639 [A/G] rs10440484 4 183011216 [A/G] rs4862025 4 183013816 [A/G] rs13140052 4 183013983 [A/G] rs335109 4 183014495 [A/G] rs749763 4 183018034 [A/G] rs335101 4 183021079 [A/G] rs335100 4 183021166 [T/C] rs6858183 4 183023753 [A/G] rs10022206 4 183023943 [T/C] rs6810793 4 183023981 [T/G] rs1470681 4 183026790 [T/G] rs13152542 4 183028134 [A/G] rs17304841 4 183029476 [A/G] rs6815885 4 183030136 [A/G] rs898131 4 183030731 [T/C] rs1458893 4 183033029 [T/C] rs17226385 4 183034755 [T/G] rs11724181 4 183035530 [T/C] rs7661253 4 183039092 [T/C] rs1450150 4 183039938 [A/G] rs3919765 4 183040169 [T/C] rs6825212 4 183040330 [T/C] rs7662442 4 183042695 [A/G] rs1114531 4 183044054 [T/C] rs7669814 4 183044215 [T/C] rs335068 4 183047903 [A/G] rs335067 4 183048696 [T/C] rs1450141 4 183060694 [A/G] NR_027107,NR_125905 LOC90768,LOC90768 EXON Silent,Silent rs1125145 4 183061232 [A/G] NR_027107,NR_125905 LOC90768,LOC90768 EXON Silent,Silent rs2309626 4 183063011 [A/C] NR_027107,NR_125905 LOC90768,LOC90768 EXON Silent,Silent rs9312290 4 183067139 [A/G] rs4862031 4 183068987 [A/G] rs4861498 4 183069376 [C/G] rs7681106 4 183072277 [T/C] rs876836 4 183077514 [T/G] rs7695632 4 183078161 [T/C] rs12640278 4 183081780 [A/G] rs12504374 4 183086701 [A/G] rs896028 4 183087547 [T/C] rs13126808 4 183091203 [T/C] rs1450149 4 183094353 [T/C] rs6815953 4 183109012 [T/G] rs1450146 4 183111871 [A/C] rs17307191 4 183114014 [A/G] rs13115107 4 183117920 [A/G] rs2726802 4 183121231 [T/C] rs17307378 4 183121623 [A/G] rs7349674 4 183123850 [T/C] rs11132117 4 183124933 [A/G] rs1450144 4 183125630 [T/C] rs17235541 4 183129070 [A/C] rs1031312 4 183132256 [A/G] rs1031313 4 183132303 [T/C] rs1031314 4 183132425 [A/G] rs4861499 4 183132543 [A/G] rs17072860 4 183136858 [A/G] rs17308154 4 183137216 [A/G] rs2726807 4 183137398 [T/C] rs6818957 4 183137612 [A/G] rs13152117 4 183138649 [A/G] rs2249112 4 183141735 [T/C] rs896024 4 183143114 [A/G] rs10015135 4 183143126 [T/C] rs2726821 4 183151151 [T/C] rs4241744 4 183157313 [A/G] rs4241745 4 183157458 [T/C] rs17072904 4 183157856 [A/G] rs4861500 4 183160086 [A/C] rs7663302 4 183161287 [A/C] rs7694663 4 183162284 [T/C] rs7656126 4 183166980 [T/G] NM_001080477 TENM3 Silent rs7687160 4 183170004 [A/G] NM_001080477 TENM3 Silent rs11724819 4 183172201 [T/C] NM_001080477 TENM3 Silent rs2726824 4 183174982 [T/C] NM_001080477 TENM3 Silent rs12640203 4 183176671 [A/C] NM_001080477 TENM3 Silent rs11736246 4 183178219 [T/C] NM_001080477 TENM3 Silent rs11940750 4 183182681 [A/G] NM_001080477 TENM3 Silent rs12648007 4 183184352 [T/G] NM_001080477 TENM3 Silent rs10011107 4 183187854 [A/G] NM_001080477 TENM3 Silent rs6825349 4 183193206 [T/C] NM_001080477 TENM3 Silent rs2063905 4 183198752 [T/G] NM_001080477 TENM3 Silent rs11732877 4 183206596 [A/G] NM_001080477 TENM3 Silent rs11943823 4 183207870 [A/G] NM_001080477 TENM3 Silent rs7684652 4 183209554 [A/C] NM_001080477 TENM3 Silent rs938526 4 183213736 [T/C] NM_001080477 TENM3 Silent rs6552549 4 183229221 [A/C] NM_001080477 TENM3 Silent rs17073038 4 183232270 [T/C] NM_001080477 TENM3 Silent rs2675539 4 183237479 [A/C] NM_001080477 TENM3 Silent rs2675534 4 183239761 [A/G] NM_001080477 TENM3 Silent rs2726822 4 183244218 [A/C] NM_001080477 TENM3 Silent rs2675531 4 183247111 [T/C] NM_001080477 TENM3 Silent rs2726805 4 183247601 [A/G] NM_001080477 TENM3 Silent rs957053 4 183248389 [A/C] NM_001080477 TENM3 Silent rs6845440 4 183248852 [T/C] NM_001080477 TENM3 Silent rs955638 4 183254661 [A/G] NM_001080477 TENM3 Silent rs1516537 4 183255434 [A/G] NM_001080477 TENM3 Silent rs7668966 4 183256787 [T/C] NM_001080477 TENM3 Silent rs7669582 4 183256975 [A/G] NM_001080477 TENM3 Silent rs10520528 4 183260601 [T/G] NM_001080477 TENM3 Silent rs1516530 4 183260894 [T/C] NM_001080477 TENM3 Silent rs9992416 4 183269989 [T/C] NM_001080477 TENM3 Silent rs4861505 4 183271349 [T/G] NM_001080477 TENM3 Silent rs2168682 4 183271631 [T/C] NM_001080477 TENM3 Silent rs13148469 4 183272312 [T/C] NM_001080477 TENM3 Silent rs6814097 4 183272589 [A/G] NM_001080477 TENM3 Silent rs35124573 4 183276790 [T/C] NM_001080477 TENM3 Silent rs6813422 4 183285393 [T/C] NM_001080477 TENM3 Silent rs6825098 4 183286640 [A/C] NM_001080477 TENM3 Silent rs13137861 4 183289625 [T/C] NM_001080477 TENM3 Silent rs13435448 4 183291465 [T/C] NM_001080477 TENM3 Silent rs6552560 4 183292629 [T/C] NM_001080477 TENM3 Silent rs930878 4 183296575 [T/G] NM_001080477 TENM3 Silent rs2309656 4 183299086 [T/C] NM_001080477 TENM3 Silent rs17073211 4 183299318 [T/G] NM_001080477 TENM3 Silent rs4862049 4 183301064 [T/G] NM_001080477 TENM3 Silent rs1878221 4 183302059 [T/C] NM_001080477 TENM3 Silent rs17073223 4 183309211 [T/G] NM_001080477 TENM3 Silent rs2045405 4 183313353 [T/C] NM_001080477 TENM3 Silent rs11935545 4 183314283 [T/C] NM_001080477 TENM3 Silent rs13109717 4 183314359 [T/C] NM_001080477 TENM3 Silent rs10520529 4 183315919 [A/G] NM_001080477 TENM3 Silent rs1516538 4 183321916 [T/G] NM_001080477 TENM3 Silent rs6823473 4 183323457 [T/C] NM_001080477 TENM3 Silent rs17253954 4 183324280 [T/G] NM_001080477 TENM3 Silent rs6830860 4 183327907 [A/G] NM_001080477 TENM3 Silent rs17073255 4 183330031 [T/C] NM_001080477 TENM3 Silent rs10050018 4 183349618 [T/C] NM_001080477 TENM3 Silent rs6822105 4 183361857 [A/G] NM_001080477 TENM3 Silent rs17073286 4 183364714 [T/C] NM_001080477 TENM3 Silent rs12498833 4 183365002 [A/G] NM_001080477 TENM3 Silent rs12505033 4 183367131 [T/C] NM_001080477 TENM3 Silent rs11736941 4 183368769 [T/C] NM_001080477 TENM3 Silent rs727695 4 183373146 [A/G] NM_001080477 TENM3 Silent rs13132492 4 183373593 [A/G] NM_001080477 TENM3 Silent rs2063906 4 183376566 [A/G] NM_001080477 TENM3 Silent rs6830998 4 183380952 [A/G] NM_001080477 TENM3 Silent rs10012537 4 183381596 [T/G] NM_001080477 TENM3 Silent rs9312297 4 183382591 [T/C] NM_001080477 TENM3 Silent rs4861512 4 183391730 [A/G] NM_001080477 TENM3 Silent rs13135084 4 183396702 [A/G] NM_001080477 TENM3 Silent rs9654295 4 183399876 [A/G] NM_001080477 TENM3 Silent rs961533 4 183404353 [T/C] NM_001080477 TENM3 Silent rs2124983 4 183404747 [A/G] NM_001080477 TENM3 Silent rs10461323 4 183405200 [T/C] NM_001080477 TENM3 Silent rs11132133 4 183405506 [A/G] NM_001080477 TENM3 Silent rs4626248 4 183405866 [A/G] NM_001080477 TENM3 Silent rs1350319 4 183407652 [T/C] NM_001080477 TENM3 Silent rs1350318 4 183407913 [T/G] NM_001080477 TENM3 Silent rs2198923 4 183408872 [T/C] NM_001080477 TENM3 Silent rs13145928 4 183409136 [A/G] NM_001080477 TENM3 Silent rs2309731 4 183412942 [T/C] NM_001080477 TENM3 Silent rs7668237 4 183415338 [A/G] NM_001080477 TENM3 Silent rs6838995 4 183417126 [A/G] NM_001080477 TENM3 Silent rs13107205 4 183417526 [A/G] NM_001080477 TENM3 Silent rs978520 4 183417581 [A/G] NM_001080477 TENM3 Silent rs10034371 4 183422459 [A/G] NM_001080477 TENM3 Silent rs13105695 4 183422869 [A/G] NM_001080477 TENM3 Silent rs6856951 4 183424808 [A/G] NM_001080477 TENM3 Silent rs4862073 4 183427057 [A/G] NM_001080477 TENM3 Silent rs10520533 4 183428859 [A/G] NM_001080477 TENM3 Silent rs10022832 4 183437511 [A/G] NM_001080477 TENM3 Silent rs7657508 4 183438470 [A/G] NM_001080477 TENM3 Silent rs11736841 4 183439439 [T/C] NM_001080477 TENM3 Silent rs6552568 4 183449806 [T/C] NM_001080477 TENM3 Silent rs7671649 4 183450690 [T/C] NM_001080477 TENM3 Silent rs869240 4 183452259 [A/G] NM_001080477 TENM3 Silent rs11731599 4 183454132 [A/G] NM_001080477 TENM3 Silent rs2309692 4 183454812 [A/G] NM_001080477 TENM3 Silent rs13110757 4 183458613 [A/G] NM_001080477 TENM3 Silent rs6812487 4 183460719 [A/G] NM_001080477 TENM3 Silent rs6840083 4 183464677 [A/G] NM_001080477 TENM3 Silent rs6812970 4 183468125 [T/C] NM_001080477 TENM3 Silent rs4428328 4 183472582 [A/G] NM_001080477 TENM3 Silent rs13144500 4 183475934 [A/C] NM_001080477 TENM3 Silent rs7674760 4 183476247 [A/G] NM_001080477 TENM3 Silent rs10013166 4 183477329 [A/G] NM_001080477 TENM3 Silent rs17258085 4 183479255 [T/C] NM_001080477 TENM3 Silent rs11937236 4 183481315 [A/G] NM_001080477 TENM3 Silent rs7670152 4 183484147 [T/G] NM_001080477 TENM3 Silent rs17258176 4 183486609 [A/G] NM_001080477 TENM3 Silent rs9996737 4 183497776 [T/G] NM_001080477 TENM3 Silent rs10020119 4 183500457 [T/G] NM_001080477 TENM3 Silent rs6552578 4 183501781 [A/G] NM_001080477 TENM3 Silent rs10520536 4 183503611 [A/G] NM_001080477 TENM3 Silent rs13145682 4 183504017 [T/C] NM_001080477 TENM3 Silent rs13136589 4 183506166 [T/C] NM_001080477 TENM3 Silent rs7694288 4 183506861 [A/G] NM_001080477 TENM3 Silent rs10033526 4 183516599 [A/C] NM_001080477 TENM3 Silent rs9985535 4 183518246 [A/G] NM_001080477 TENM3 Silent rs6833629 4 183521798 [A/G] NM_001080477 TENM3 Silent rs11132137 4 183525697 [T/C] NM_001080477 TENM3 Silent rs6814485 4 183526414 [A/G] NM_001080477 TENM3 Silent rs13109227 4 183529154 [A/C] NM_001080477 TENM3 Silent rs6818350 4 183532267 [A/C] NM_001080477 TENM3 Silent rs17324394 4 183533788 [T/C] NM_001080477 TENM3 Silent rs12499296 4 183536086 [A/G] NM_001080477 TENM3 Silent rs6843930 4 183541307 [A/G] NM_001080477 TENM3 Silent rs12648727 4 183543569 [A/G] NM_001080477 TENM3 Silent rs11132138 4 183543770 [T/C] NM_001080477 TENM3 Silent rs6552585 4 183545589 [T/C] NM_001080477 TENM3 Silent rs12504411 4 183546180 [T/G] NM_001080477 TENM3 Silent rs7693901 4 183550589 [T/C] NM_001080477 TENM3 Silent rs1554037 4 183550637 [A/G] NM_001080477 TENM3 Silent rs6841261 4 183553052 [A/G] NM_001080477 TENM3 Silent rs12639914 4 183553276 [A/G] NM_001080477 TENM3 Silent rs1013096 4 183553837 [A/G] NM_001080477 TENM3 Silent rs17325360 4 183556869 [A/G] NM_001080477 TENM3 Silent rs10520539 4 183556999 [T/C] NM_001080477 TENM3 Silent rs7688538 4 183559306 [T/C] NM_001080477 TENM3 Silent rs4507403 4 183559425 [T/C] NM_001080477 TENM3 Silent rs11930604 4 183561942 [T/C] NM_001080477 TENM3 Silent rs11722354 4 183565618 [T/C] NM_001080477 TENM3 Silent rs6552587 4 183567188 [T/G] NM_001080477 TENM3 Silent rs6850978 4 183572390 [T/C] NM_001080477 TENM3 Silent rs1514473 4 183574444 [T/C] NM_001080477 TENM3 Silent rs17073713 4 183574838 [A/G] NM_001080477 TENM3 Silent rs11937177 4 183576221 [A/G] NM_001080477 TENM3 Silent rs9312302 4 183578598 [A/G] NM_001080477 TENM3 Silent rs4386638 4 183581152 [A/G] NM_001080477 TENM3 Silent rs10428431 4 183583762 [T/G] NM_001080477 TENM3 Silent rs17073734 4 183584040 [A/G] NM_001080477 TENM3 Silent rs12648977 4 183589823 [T/C] NM_001080477 TENM3 Silent rs2309774 4 183590236 [A/C] NM_001080477 TENM3 Silent rs2309760 4 183591332 [A/G] NM_001080477 TENM3 Silent rs11132145 4 183591707 [T/C] NM_001080477 TENM3 Silent rs2309759 4 183593318 [A/G] NM_001080477 TENM3 Silent rs4535369 4 183594938 [A/G] NM_001080477 TENM3 Silent rs4618351 4 183604892 [A/G] NM_001080477 TENM3 Silent rs11938233 4 183605088 [A/G] NM_001080477 TENM3 Silent rs7697828 4 183608189 [A/G] NM_001080477 TENM3 Silent rs6845497 4 183611553 [A/G] NM_001080477 TENM3 Silent rs7694547 4 183612535 [T/G] NM_001080477 TENM3 Silent rs17073853 4 183613352 [T/C] NM_001080477 TENM3 Silent rs17073855 4 183613431 [A/G] NM_001080477 TENM3 Silent rs1987079 4 183616911 [A/G] NM_001080477 TENM3 Silent rs4241748 4 183618777 [T/C] NM_001080477 TENM3 Silent rs10434298 4 183622901 [T/C] NM_001080477 TENM3 Silent rs6858496 4 183626332 [T/C] NM_001080477 TENM3 Silent rs6841510 4 183628586 [A/G] NM_001080477 TENM3 Silent rs12498650 4 183628872 [A/G] NM_001080477 TENM3 Silent rs17073904 4 183632213 [T/G] NM_001080477 TENM3 Silent rs6827132 4 183633697 [T/C] NM_001080477 TENM3 Silent rs13101364 4 183640777 [A/G] NM_001080477 TENM3 Silent rs11721401 4 183647869 [A/G] NM_001080477 TENM3 Silent rs13340295 4 183650100 [A/G] NM_001080477 TENM3 Silent rs6829893 4 183651765 [A/G] NM_001080477 TENM3 Silent rs13435237 4 183654099 [A/G] NM_001080477 TENM3 Silent rs6833719 4 183655548 [T/C] NM_001080477 TENM3 Silent rs4241750 4 183655636 [T/C] NM_001080477 TENM3 Silent rs4557308 4 183655750 [A/G] NM_001080477 TENM3 Silent rs10021016 4 183661413 [A/G] NM_001080477 TENM3 Silent rs12648546 4 183661673 [A/C] NM_001080477 TENM3 Silent rs11734588 4 183662527 [A/G] NM_001080477 TENM3 Silent rs6552603 4 183663175 [T/G] NM_001080477 TENM3 Silent rs7654255 4 183664522 [T/C] NM_001080477 TENM3 EXON Synonymous_Y1193Y rs7690035 4 183666740 [A/G] NM_001080477 TENM3 Silent rs33914616 4 183675227 [T/C] NM_001080477 TENM3 Silent rs11736855 4 183677453 [T/C] NM_001080477 TENM3 Silent rs10028158 4 183680961 [A/G] NM_001080477 TENM3 Silent rs4862091 4 183684204 [T/C] NM_001080477 TENM3 Silent rs11727669 4 183684925 [T/G] NM_001080477 TENM3 Silent rs17074036 4 183685402 [A/G] NM_001080477 TENM3 Silent rs17264104 4 183686235 [A/C] NM_001080477 TENM3 Silent rs17074039 4 183689445 [T/C] NM_001080477 TENM3 Silent rs17074042 4 183689629 [A/G] NM_001080477 TENM3 Silent rs17074044 4 183689666 [A/G] NM_001080477 TENM3 Silent rs17330237 4 183692079 [A/G] NM_001080477 TENM3 Silent rs4577620 4 183692580 [A/G] NM_001080477 TENM3 Silent rs4467618 4 183692641 [A/G] NM_001080477 TENM3 Silent rs12500335 4 183707781 [A/G] NM_001080477 TENM3 Silent rs12508106 4 183707836 [A/G] NM_001080477 TENM3 Silent rs10006225 4 183708996 [T/G] NM_001080477 TENM3 Silent rs17074066 4 183709536 [T/C] NM_001080477 TENM3 Silent rs3805200 4 183709842 [A/G] NM_001080477 TENM3 Silent rs6842610 4 183715225 [T/G] NM_001080477 TENM3 Silent rs2309772 4 183716648 [A/C] NM_001080477 TENM3 Silent rs2309777 4 183722743 [T/C] NM_001080477 TENM3 EXON Silent rs17267298 4 183730650 [T/C] rs13124391 4 183731737 [T/G] rs6858295 4 183735049 [T/C] rs4862103 4 183735309 [A/G] rs4241754 4 183744704 [T/C] rs13133452 4 183750550 [T/C] rs6854616 4 183761427 [A/G] rs4862116 4 183763618 [A/G] rs6822595 4 183768698 [A/G] rs4862117 4 183769467 [T/G] rs7680411 4 183771387 [T/C] rs10025192 4 183775313 [T/C] rs13118559 4 183778572 [T/C] rs11736797 4 183778788 [T/C] rs4862122 4 183782993 [T/C] rs4861534 4 183791706 [A/G] rs17074159 4 183792885 [T/C] rs11132155 4 183793275 [T/C] rs17265016 4 183796259 [A/G] rs11132156 4 183797355 [T/C] rs17271644 4 183809272 [T/C] rs6829021 4 183810141 [A/G] rs6834938 4 183810813 [T/C] rs6835318 4 183810865 [A/G] rs7278 4 183811487 [A/G] NM_001351745,NM_001351753,NM_001351744,NM_001351750,NM_001351747,NM_001012732,NM_001921,NM_001351743,NM_001351748 DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7277 4 183811513 [T/C] NM_001351745,NM_001351753,NM_001351744,NM_001351750,NM_001351747,NM_001012732,NM_001921,NM_001351743,NM_001351748 DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3190314 4 183812287 [A/G] NM_001351745,NM_001351753,NM_001351744,NM_001351750,NM_001351747,NM_001012732,NM_001921,NM_001351743,NM_001351748 DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9542 4 183812351 [T/C] NM_001351745,NM_001351753,NM_001351744,NM_001351750,NM_001351747,NM_001012732,NM_001921,NM_001351743,NM_001351748 DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2515683 4 183813147 [T/C] NM_001351745,NM_001351753,NM_001351744,NM_001351750,NM_001351747,NM_001012732,NM_001921,NM_001351743,NM_001351748 DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12507552 4 183813425 [T/C] NM_001351745,NM_001351753,NM_001351744,NM_001351750,NM_001351747,NM_001012732,NM_001921,NM_001351743,NM_001351748 DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17331744 4 183815561 [T/C] NM_001351745,NM_001351753,NM_001351744,NM_001351750,NM_001351747,NM_001012732,NM_001921,NM_001351743,NM_001351748 DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6834019 4 183817659 [A/C] NM_001351745,NM_001351753,NM_001351744,NM_001351750,NM_001351747,NM_001012732,NM_001921,NM_001351743,NM_001351748 DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6831306 4 183819095 [T/C] NM_001351745,NM_001351753,NM_001351744,NM_001351750,NM_001351747,NM_001012732,NM_001921,NM_001351743,NM_001351748 DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13114435 4 183821662 [T/C] NM_001351745,NM_001351753,NM_001351744,NM_001351750,NM_001351747,NM_001012732,NM_001921,NM_001351743,NM_001351748 DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13101260 4 183823597 [A/G] NM_001351745,NM_001351753,NM_001351744,NM_001351750,NM_001351747,NM_001012732,NM_001921,NM_001351743,NM_001351748 DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10016530 4 183824984 [A/C] NM_001351745,NM_001351753,NM_001351744,NM_001351750,NM_001351747,NM_001012732,NM_001921,NM_001351743,NM_001351748 DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13111117 4 183825476 [A/G] NM_001351745,NM_001351753,NM_001351744,NM_001351750,NM_001351747,NM_001012732,NM_001921,NM_001351743,NM_001351748 DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6823077 4 183833942 [A/C] NM_001351745,NM_001351753,NM_001351744,NM_001351750,NM_001351747,NM_001012732,NM_001921,NM_001351743,NM_001351748 DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD,DCTD Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs5016499 4 183840898 [T/G] rs13117933 4 183849072 [A/G] rs10520544 4 183849605 [T/G] rs11737887 4 183850395 [T/C] rs4131396 4 183858411 [T/C] rs17074303 4 183868015 [T/C] rs4607268 4 183872630 [A/G] rs4453974 4 183873241 [T/C] rs7655196 4 183880034 [A/G] rs2714510 4 183880263 [T/C] rs6830570 4 183892717 [T/G] rs2709350 4 183896828 [T/C] rs1454371 4 183907715 [T/C] rs4069861 4 183916674 [T/G] rs1377943 4 183929581 [T/C] rs9998545 4 183931994 [T/C] rs2278924 4 183932844 [T/G] rs17074373 4 183934000 [T/C] rs2714546 4 183934023 [A/G] rs17334067 4 183934142 [T/C] rs2714545 4 183935289 [T/C] rs7660903 4 183942308 [T/C] rs17274861 4 183944066 [A/G] rs1902044 4 183947384 [T/C] rs747368 4 183951585 [T/C] rs2603348 4 183957884 [T/G] rs2016910 4 183959226 [T/G] NR_003612 FAM92A1P2 EXON Silent rs4450975 4 183963607 [T/C] rs6850320 4 183989102 [A/G] rs10520548 4 183994213 [T/C] rs6825466 4 183995589 [T/C] rs11736402 4 184010717 [A/G] rs936044 4 184040122 [T/C] NM_024949 WWC2 Silent rs6846985 4 184060896 [A/G] NM_024949 WWC2 Silent rs11935093 4 184063608 [T/G] NM_024949 WWC2 Silent rs10520545 4 184070426 [T/G] NM_024949 WWC2 Silent rs4469120 4 184098334 [A/G] NM_024949 WWC2 Silent rs6845251 4 184122020 [T/C] NM_024949 WWC2 Silent rs4615211 4 184124987 [T/C] NM_024949 WWC2 Silent rs6831552 4 184127332 [T/C] NM_024949 WWC2 Silent rs1877290 4 184132563 [T/G] NM_024949 WWC2 Silent rs12643595 4 184139997 [T/C] NM_024949 WWC2 Silent rs6855711 4 184144709 [T/G] NM_024949 WWC2 Silent rs17074498 4 184148366 [A/G] NM_024949 WWC2 Silent rs7688139 4 184155515 [T/G] NM_024949,NR_126473 WWC2,WWC2-AS1 Silent,Silent rs17290885 4 184168117 [T/C] NM_024949 WWC2 Silent rs10020261 4 184171187 [T/C] NM_024949 WWC2 Silent rs6841933 4 184173041 [A/G] NM_024949 WWC2 Silent rs7695317 4 184179699 [A/G] NM_024949 WWC2 Silent rs7438080 4 184183588 [A/G] NM_024949 WWC2 Silent rs6812460 4 184188404 [A/G] NM_024949 WWC2 Silent rs3926627 4 184189952 [A/G] NM_024949 WWC2 Silent rs1473070 4 184192037 [T/C] NM_024949 WWC2 Silent rs9996190 4 184196516 [T/G] NM_024949 WWC2 Silent rs13116042 4 184197313 [T/C] NM_024949 WWC2 Silent rs12643425 4 184201182 [T/G] NM_024949 WWC2 Silent rs11132173 4 184201909 [A/G] NM_024949 WWC2 Silent rs11132174 4 184202148 [T/G] NM_024949 WWC2 Silent rs17291855 4 184206296 [A/G] NM_024949 WWC2 Silent rs955748 4 184215675 [A/G] NM_024949 WWC2 Silent rs2175476 4 184215832 [A/G] NM_024949 WWC2 Silent rs6811091 4 184221172 [A/G] NM_024949 WWC2 Silent rs17074589 4 184224437 [A/G] NM_024949 WWC2 Silent rs11929772 4 184225421 [A/G] NM_024949 WWC2 Silent rs11730648 4 184226187 [A/G] NM_024949 WWC2 Silent rs2309875 4 184227066 [T/C] NM_024949 WWC2 Silent rs1397942 4 184228248 [A/G] NM_024949 WWC2 Silent rs10003798 4 184230630 [T/C] NM_024949 WWC2 Silent rs6849819 4 184232252 [A/G] NM_024949 WWC2 Silent rs907360 4 184234587 [T/C] NM_024949 WWC2 Silent rs13141994 4 184235796 [A/G] NM_024949 WWC2 Silent rs4862155 4 184236868 [A/G] NM_024949 WWC2 EXON Missense_A1189T rs7688467 4 184243528 [A/G] NM_001185149 CLDN24 EXON Missense_L18F rs2048472 4 184249490 [T/C] rs35432122 4 184251370 [T/C] rs907365 4 184252789 [T/G] rs4616804 4 184259614 [A/G] rs10029290 4 184270907 [A/C] rs7669080 4 184271019 [A/G] rs4861543 4 184276454 [T/C] rs17074631 4 184277307 [A/G] rs907364 4 184278868 [T/G] rs7687627 4 184279303 [A/C] rs4861544 4 184279613 [A/G] rs868083 4 184280695 [T/C] rs868082 4 184280944 [A/G] rs9992054 4 184281811 [T/C] rs9995832 4 184283411 [T/G] rs13151481 4 184285017 [T/C] rs6552661 4 184285089 [T/C] rs6820687 4 184285671 [T/C] rs1106052 4 184289319 [T/C] rs6821104 4 184292528 [T/C] rs4862171 4 184292904 [A/G] rs6847638 4 184292928 [T/C] rs17074696 4 184293030 [T/C] rs6834774 4 184294510 [T/C] rs11931607 4 184296685 [T/C] rs955229 4 184296883 [T/C] rs4602536 4 184298419 [A/G] rs17074703 4 184300125 [T/C] rs17293543 4 184302049 [A/G] rs1467097 4 184302372 [T/C] rs17293620 4 184302549 [T/G] rs12641554 4 184302684 [A/G] rs1588571 4 184305340 [T/C] rs1511674 4 184306513 [A/G] rs17074720 4 184311757 [A/G] rs11132179 4 184311806 [A/G] rs7699622 4 184315862 [A/G] rs17294373 4 184323148 [T/C] rs17074737 4 184323266 [T/C] rs17074740 4 184323983 [A/C] rs4862177 4 184325258 [T/C] rs4862179 4 184325450 [A/G] rs11725216 4 184334102 [T/C] rs4415002 4 184335306 [T/C] rs6552667 4 184338589 [T/C] rs6858319 4 184345714 [A/G] rs4241767 4 184353138 [T/C] rs6842529 4 184356197 [A/G] rs13111484 4 184356574 [A/C] rs4485840 4 184359288 [T/C] rs4862197 4 184362046 [T/C] rs4861551 4 184362068 [T/C] rs3187025 4 184369040 [A/G] NM_001317343,NM_017632 CDKN2AIP,CDKN2AIP EXON Silent,Silent rs6844630 4 184373811 [A/G] rs6816216 4 184376851 [A/C] rs4241775 4 184384311 [A/G] rs4273514 4 184389698 [T/C] rs10007707 4 184394392 [A/G] rs4862210 4 184399833 [T/C] rs7677714 4 184412581 [T/C] rs6850330 4 184415303 [A/C] rs11723316 4 184415338 [A/C] rs11943515 4 184416995 [A/G] NR_033995 LOC389247 Silent rs8872 4 184426387 [T/C] NM_001564 ING2 EXON Synonymous_A13A rs4862213 4 184428744 [A/G] NM_001564,NM_001291959 ING2,ING2 Silent,Silent rs6830958 4 184429659 [A/G] NM_001564,NM_001291959 ING2,ING2 Silent,Silent rs10013043 4 184431293 [A/C] NM_001564,NM_001291959 ING2,ING2 Silent,Silent rs10024955 4 184434622 [A/G] rs6838723 4 184438322 [A/G] rs13141754 4 184441694 [A/G] rs11732255 4 184441917 [T/G] rs7658620 4 184447081 [A/G] rs4440262 4 184454079 [T/G] rs7670109 4 184454194 [A/G] rs4524431 4 184458946 [A/G] rs4550975 4 184462577 [T/C] rs7699347 4 184463695 [A/G] rs10017798 4 184465856 [T/G] rs4426827 4 184468253 [A/G] rs11726805 4 184471255 [T/C] rs4862223 4 184473333 [A/C] rs4292366 4 184478353 [T/G] rs6841041 4 184479380 [A/C] rs6811805 4 184481702 [A/G] rs7694722 4 184487521 [A/G] rs11723412 4 184494270 [T/C] rs10009455 4 184494883 [A/G] rs7662749 4 184501675 [T/C] rs11132193 4 184503980 [A/G] rs13127102 4 184504511 [T/C] rs4861562 4 184507283 [T/C] rs10011527 4 184507881 [T/C] rs4394039 4 184510402 [T/C] rs7656979 4 184517243 [A/G] rs12641020 4 184523965 [T/C] rs7674701 4 184525386 [A/C] rs9884125 4 184526440 [A/G] rs4543168 4 184529029 [T/G] rs7671807 4 184529969 [A/C] rs13118994 4 184530109 [T/C] rs4624699 4 184534704 [T/C] rs4566695 4 184534983 [T/G] rs13128324 4 184535274 [A/G] rs12510912 4 184536452 [A/G] rs12504367 4 184537343 [A/G] rs12504410 4 184537463 [A/G] rs7656347 4 184540054 [A/C] rs11132199 4 184542062 [T/C] rs13124076 4 184546565 [A/G] rs6830164 4 184551432 [T/C] rs7679973 4 184569516 [T/C] NM_001307922,NM_152682 RWDD4,RWDD4 Silent,Silent rs6552695 4 184571085 [A/G] NM_001307922,NM_152682 RWDD4,RWDD4 Silent,Silent rs4547833 4 184572036 [T/C] NM_001307922,NM_152682 RWDD4,RWDD4 Silent,Silent rs6832981 4 184572951 [A/G] NM_001307922,NM_152682 RWDD4,RWDD4 Silent,Silent rs10033002 4 184573379 [A/G] NM_001307922,NM_152682 RWDD4,RWDD4 Silent,Silent rs9790676 4 184575568 [T/C] NM_001307922,NM_152682 RWDD4,RWDD4 Silent,Silent rs6838230 4 184577177 [T/C] NM_001307922,NM_152682 RWDD4,RWDD4 Silent,Silent rs5019706 4 184577348 [A/G] NM_001307922,NM_152682 RWDD4,RWDD4 Silent,Silent rs4400034 4 184586738 [T/G] NM_021942,NM_199053 TRAPPC11,TRAPPC11 Silent,Silent rs4282227 4 184588121 [T/C] NM_021942,NM_199053 TRAPPC11,TRAPPC11 Silent,Silent rs7684339 4 184590150 [T/C] NM_021942,NM_199053 TRAPPC11,TRAPPC11 Silent,Silent rs11132206 4 184606653 [A/G] NM_021942,NM_199053 TRAPPC11,TRAPPC11 Silent,Silent rs10018951 4 184609373 [T/C] NM_021942,NM_199053 TRAPPC11,TRAPPC11 Silent,Silent rs10019182 4 184609457 [A/G] NM_021942,NM_199053 TRAPPC11,TRAPPC11 Silent,Silent rs13149502 4 184610208 [T/C] NM_021942,NM_199053 TRAPPC11,TRAPPC11 Silent,Silent rs4862234 4 184614874 [T/C] NM_021942,NM_199053 TRAPPC11,TRAPPC11 EXON Synonymous_T790T,Synonymous_T790T rs4583804 4 184628710 [A/C] NM_021942,NM_199053 TRAPPC11,TRAPPC11 Silent,Silent rs9312318 4 184629794 [A/G] NM_021942,NM_199053 TRAPPC11,TRAPPC11 Silent,Silent rs13146475 4 184631294 [A/G] NM_021942,NM_199053 TRAPPC11,TRAPPC11 Silent,Silent rs12642166 4 184634741 [A/G] NM_021942,NM_199053 TRAPPC11,TRAPPC11 EXON Silent,Silent rs4241780 4 184638760 [T/C] rs4327526 4 184639740 [A/G] rs4862241 4 184641445 [T/C] rs10000388 4 184648954 [T/C] rs12499750 4 184651150 [A/G] rs11735908 4 184655041 [A/G] rs13132455 4 184659447 [T/C] rs4132292 4 184660531 [T/C] rs4130368 4 184668956 [A/G] rs6552702 4 184673268 [A/G] rs4862250 4 184686219 [A/C] rs4862251 4 184687644 [T/C] rs10028767 4 184688001 [T/G] rs4538533 4 184689409 [A/G] rs4568278 4 184689417 [A/G] rs13117971 4 184692389 [T/C] rs4129955 4 184694074 [T/C] rs10018596 4 184694959 [T/C] rs4368651 4 184697378 [A/G] rs6845392 4 184697574 [T/G] rs13142457 4 184704385 [T/C] rs4370182 4 184712051 [T/G] rs9990869 4 184720139 [T/C] NR_132761 STOX2 Silent rs10019343 4 184721809 [A/G] NR_132761 STOX2 Silent rs930306 4 184725906 [T/C] NR_132761 STOX2 Silent rs11722400 4 184727641 [A/C] NR_132761 STOX2 Silent rs7659026 4 184728682 [T/C] NR_132761 STOX2 Silent rs7659056 4 184728730 [T/C] NR_132761 STOX2 Silent rs7666373 4 184730177 [A/C] NR_132761 STOX2 Silent rs17075058 4 184749270 [A/G] NR_132761 STOX2 Silent rs17075077 4 184754273 [A/G] NR_132761 STOX2 Silent rs13106255 4 184762700 [A/G] NR_132761 STOX2 Silent rs7695711 4 184767521 [T/C] NR_132761 STOX2 Silent rs6813846 4 184770923 [A/G] NR_132761 STOX2 Silent rs6552711 4 184779187 [T/G] NR_132761 STOX2 Silent rs892836 4 184781037 [A/G] NR_132761 STOX2 Silent rs6852989 4 184781947 [T/G] NR_132761 STOX2 Silent rs13150058 4 184782619 [T/G] NR_132761 STOX2 Silent rs4416516 4 184783233 [T/C] NR_132761 STOX2 Silent rs6824804 4 184784920 [A/G] NR_132761 STOX2 Silent rs13435909 4 184787159 [A/G] NR_132761 STOX2 Silent rs17075108 4 184789877 [A/G] NR_132761 STOX2 Silent rs11729441 4 184790301 [A/G] NR_132761 STOX2 Silent rs11737799 4 184790373 [T/C] NR_132761 STOX2 Silent rs2164303 4 184794696 [T/C] NR_132761 STOX2 Silent rs7678253 4 184796501 [A/G] NR_132761 STOX2 Silent rs7688995 4 184799985 [T/C] NR_132761 STOX2 Silent rs7657089 4 184805900 [T/C] NR_132761 STOX2 Silent rs1469809 4 184808546 [A/G] NR_132761 STOX2 Silent rs2871381 4 184811318 [A/G] NR_132761 STOX2 Silent rs1369445 4 184813876 [A/G] NR_132761 STOX2 Silent rs12507827 4 184822388 [A/G] NR_132761 STOX2 Silent rs17075136 4 184825696 [A/G] NR_132761 STOX2 Silent rs1560982 4 184826026 [A/G] NR_132761 STOX2 Silent rs1978777 4 184836189 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs2309942 4 184839829 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs6552719 4 184841111 [T/C] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs6818342 4 184841970 [T/C] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs7696821 4 184848691 [T/C] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs17363081 4 184848958 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs892835 4 184849456 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs6552722 4 184852627 [A/C] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs2309944 4 184858078 [T/C] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs4861584 4 184865121 [T/C] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs12502711 4 184866656 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs6853748 4 184870145 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs2871385 4 184875120 [A/C] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs10213203 4 184876413 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs9999145 4 184882782 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs4861596 4 184886694 [A/C] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs2309949 4 184902533 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs4862279 4 184905482 [A/C] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs12513114 4 184905863 [T/C] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs7685679 4 184906674 [T/C] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs4397039 4 184911340 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs17090673 4 184918852 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs12498735 4 184921299 [T/C] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs3749534 4 184922669 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs10212888 4 184924281 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs10213018 4 184925991 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs7655396 4 184928980 [T/C] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs4861597 4 184931818 [A/G] NR_132761,NM_020225 STOX2,STOX2 EXON Silent,Synonymous_T609T rs3811775 4 184936790 [A/G] NR_132761,NM_020225 STOX2,STOX2 Silent,Silent rs3749531 4 184943274 [T/G] NR_132761,NM_020225 STOX2,STOX2 EXON Silent,Silent rs7690914 4 184952005 [A/G] rs6552733 4 184952645 [A/C] rs4862292 4 184958217 [T/C] rs4391081 4 184974318 [T/C] rs11725377 4 184974967 [T/C] rs4862298 4 184988203 [T/C] rs12650935 4 184989565 [A/G] rs4862299 4 184990090 [A/G] rs6552744 4 184993366 [T/C] rs11939877 4 184995011 [T/C] rs4862305 4 184996810 [A/G] rs6829678 4 185001631 [T/C] rs6552748 4 185002243 [A/C] rs7690586 4 185009856 [A/G] rs4479748 4 185012398 [T/C] NM_153343 ENPP6 EXON Missense_S419G rs6819770 4 185016399 [T/C] NM_153343 ENPP6 Silent rs4488969 4 185018446 [T/C] NM_153343 ENPP6 EXON Missense_D357N rs7669472 4 185019266 [T/C] NM_153343 ENPP6 Silent rs6810830 4 185023528 [T/C] NM_153343 ENPP6 Silent rs12501526 4 185023826 [T/G] NM_153343 ENPP6 Silent rs11132222 4 185024257 [A/G] NM_153343 ENPP6 Silent rs11132224 4 185026377 [T/C] NM_153343 ENPP6 Silent rs10010069 4 185027064 [T/C] NM_153343 ENPP6 Silent rs4241784 4 185032985 [T/G] NM_153343 ENPP6 Silent rs4862310 4 185034183 [T/G] NM_153343 ENPP6 Silent rs4861602 4 185042789 [A/G] NM_153343 ENPP6 Silent rs17486603 4 185062681 [T/C] NM_153343 ENPP6 Silent rs4554119 4 185062880 [T/C] NM_153343 ENPP6 Silent rs4421030 4 185066950 [A/C] NM_153343 ENPP6 Silent rs4862319 4 185070555 [T/G] NM_153343 ENPP6 Silent rs4862321 4 185071227 [T/C] NM_153343 ENPP6 Silent rs4241790 4 185072020 [A/C] NM_153343 ENPP6 Silent rs13147555 4 185074686 [A/C] NM_153343 ENPP6 Silent rs9992036 4 185076246 [A/G] NM_153343 ENPP6 Silent rs7689119 4 185076530 [A/G] NM_153343 ENPP6 Silent rs1921564 4 185078076 [A/G] NM_153343 ENPP6 Silent rs2310044 4 185086713 [A/G] NM_153343 ENPP6 Silent rs1921561 4 185088648 [T/C] NM_153343 ENPP6 Silent rs1921560 4 185088697 [T/G] NM_153343 ENPP6 Silent rs9637691 4 185091025 [T/C] NM_153343 ENPP6 Silent rs11722344 4 185091885 [T/C] NM_153343 ENPP6 Silent rs6810545 4 185094473 [A/G] NM_153343 ENPP6 Silent rs11132230 4 185095230 [T/C] NM_153343 ENPP6 Silent rs2178570 4 185096468 [A/G] NM_153343 ENPP6 Silent rs6842767 4 185104471 [A/G] NM_153343 ENPP6 Silent rs6552765 4 185109553 [A/G] NM_153343 ENPP6 Silent rs10520559 4 185111580 [T/C] NM_153343 ENPP6 Silent rs4452474 4 185111634 [A/C] NM_153343 ENPP6 Silent rs11929900 4 185116050 [T/C] NM_153343 ENPP6 Silent rs11930046 4 185116224 [A/G] NM_153343 ENPP6 Silent rs4862330 4 185117077 [T/C] NM_153343 ENPP6 Silent rs17584314 4 185121167 [T/C] NM_153343 ENPP6 Silent rs17075449 4 185121577 [T/C] NM_153343 ENPP6 Silent rs4862338 4 185121619 [T/C] NM_153343 ENPP6 Silent rs12647212 4 185123138 [A/G] NM_153343 ENPP6 Silent rs17075459 4 185123650 [T/C] NM_153343 ENPP6 Silent rs1882331 4 185123766 [T/C] NM_153343 ENPP6 Silent rs4862339 4 185124123 [A/G] NM_153343 ENPP6 Silent rs10005433 4 185125620 [A/C] NM_153343 ENPP6 Silent rs10011933 4 185127748 [T/C] NM_153343 ENPP6 Silent rs17679896 4 185128095 [T/C] NM_153343 ENPP6 Silent rs11724229 4 185128641 [A/G] NM_153343 ENPP6 Silent rs1921563 4 185137228 [A/G] NM_153343 ENPP6 Silent rs1882328 4 185137253 [T/C] NM_153343 ENPP6 Silent rs6819977 4 185137596 [A/C] NM_153343 ENPP6 Silent rs11132235 4 185142116 [T/C] rs6853677 4 185148372 [A/G] rs1217965 4 185149599 [A/G] rs12644741 4 185150443 [A/G] rs938016 4 185152834 [T/C] rs17584650 4 185160596 [A/G] rs1217960 4 185162040 [T/C] rs1217957 4 185164636 [T/C] rs7696184 4 185165607 [T/C] rs1217945 4 185170812 [A/G] rs2248232 4 185172565 [A/G] rs2703731 4 185173385 [T/G] rs13138586 4 185173887 [A/G] rs6825291 4 185173993 [T/C] rs3946906 4 185175421 [T/C] rs2457671 4 185176066 [A/C] rs2175292 4 185176608 [T/C] rs938015 4 185176699 [T/C] rs13143328 4 185177783 [T/C] rs13143366 4 185177832 [T/G] rs12503492 4 185179394 [A/G] rs2665721 4 185181393 [T/C] rs11727655 4 185182695 [T/C] rs6856666 4 185183535 [T/C] rs877378 4 185186535 [A/G] rs4862347 4 185191779 [A/G] rs793913 4 185192543 [T/C] rs793911 4 185193099 [A/G] rs793908 4 185194074 [T/G] rs7670891 4 185196778 [A/G] rs812666 4 185197061 [A/G] rs17487801 4 185203124 [A/G] rs3796693 4 185205186 [A/G] rs3796692 4 185205210 [T/C] rs1217969 4 185209537 [A/G] rs12650772 4 185215134 [A/G] rs2703737 4 185217303 [A/G] rs6552771 4 185217356 [A/G] rs4862356 4 185220262 [A/G] rs6841399 4 185221748 [A/G] rs1467069 4 185222701 [T/C] rs10029721 4 185226573 [A/G] rs10008153 4 185227184 [T/C] rs12506922 4 185234505 [T/G] rs6819481 4 185238400 [T/C] rs12650550 4 185241316 [T/C] rs12641965 4 185241610 [A/C] rs999759 4 185245514 [T/C] rs793890 4 185248266 [A/G] rs793892 4 185249147 [T/C] rs13149699 4 185251371 [A/G] rs793899 4 185252818 [T/C] rs793882 4 185256315 [T/C] rs6552774 4 185257159 [A/G] rs4269220 4 185259670 [T/G] rs793878 4 185262740 [T/G] NR_040108 LINC02363 EXON Silent rs793879 4 185263811 [A/G] NR_040108 LINC02363 Silent rs793880 4 185265401 [A/G] NR_040108 LINC02363 Silent rs712032 4 185273483 [A/G] NR_040108 LINC02363 Silent rs4326049 4 185278885 [A/G] rs4590089 4 185279284 [T/C] rs6834535 4 185280853 [T/C] rs4861621 4 185284684 [A/G] rs17624012 4 185286768 [A/G] NR_125933,NR_125934 LINC02362,LINC02362 EXON Silent,Silent rs11727845 4 185287351 [T/G] NR_125933,NR_125934 LINC02362,LINC02362 Silent,Silent rs12512537 4 185287522 [A/G] NR_125933,NR_125934 LINC02362,LINC02362 Silent,Silent rs17051405 4 185287935 [A/G] NR_125933,NR_125934 LINC02362,LINC02362 Silent,Silent rs4642292 4 185290163 [T/C] NR_125933,NR_125934 LINC02362,LINC02362 Silent,Silent rs1935847 4 185299681 [T/C] NR_125933,NR_125934 LINC02362,LINC02362 Silent,Silent rs12505296 4 185299830 [T/C] NR_125933,NR_125934 LINC02362,LINC02362 Silent,Silent rs6831978 4 185303451 [A/G] NR_125933,NR_125934 LINC02362,LINC02362 EXON Silent,Silent rs1105207 4 185304463 [T/C] rs4629495 4 185305366 [T/C] rs11732927 4 185307045 [T/C] rs2282458 4 185307660 [A/C] rs6817412 4 185308459 [A/G] rs3775543 4 185310218 [T/C] NM_002199 IRF2 EXON Synonymous_G248G rs13119453 4 185311570 [A/G] NM_002199 IRF2 Silent rs6856910 4 185312355 [T/C] NM_002199 IRF2 Silent rs793779 4 185312684 [T/C] NM_002199 IRF2 Silent rs3756089 4 185315792 [T/C] NM_002199 IRF2 Silent rs965225 4 185316897 [T/C] NM_002199 IRF2 Silent rs11132242 4 185321941 [A/G] NM_002199 IRF2 Silent rs3756090 4 185322520 [A/G] NM_002199 IRF2 Silent rs724528 4 185323726 [A/G] NM_002199 IRF2 Silent rs7655371 4 185324939 [T/C] NM_002199 IRF2 Silent rs6812958 4 185325242 [A/G] NM_002199 IRF2 Silent rs17075783 4 185325492 [T/C] NM_002199 IRF2 Silent rs3775553 4 185328817 [A/G] NM_002199 IRF2 Silent rs2241500 4 185329052 [A/G] NM_002199 IRF2 Silent rs17686080 4 185330598 [T/C] NM_002199 IRF2 Silent rs6816525 4 185330651 [A/G] NM_002199 IRF2 Silent rs17624154 4 185330669 [T/C] NM_002199 IRF2 Silent rs7685555 4 185331345 [T/C] NM_002199 IRF2 Silent rs3775556 4 185331977 [A/G] NM_002199 IRF2 Silent rs1425552 4 185332571 [T/C] NM_002199 IRF2 Silent rs10009261 4 185333030 [T/C] NM_002199 IRF2 Silent rs13115095 4 185336262 [A/G] NM_002199 IRF2 Silent rs7677486 4 185336852 [T/C] NM_002199 IRF2 Silent rs2288247 4 185338921 [T/C] NM_002199 IRF2 Silent rs890193 4 185343635 [T/C] NM_002199 IRF2 Silent rs6827018 4 185344606 [A/G] NM_002199 IRF2 Silent rs11945823 4 185344657 [T/C] NM_002199 IRF2 Silent rs6827840 4 185344932 [T/C] NM_002199 IRF2 Silent rs10011243 4 185346090 [A/G] NM_002199 IRF2 Silent rs11726275 4 185348916 [A/G] NM_002199 IRF2 Silent rs3756094 4 185350934 [A/G] NM_002199 IRF2 Silent rs744038 4 185352413 [T/C] NM_002199 IRF2 Silent rs12504466 4 185353799 [T/C] NM_002199 IRF2 Silent rs3756095 4 185354298 [T/C] NM_002199 IRF2 Silent rs3756097 4 185354354 [T/C] NM_002199 IRF2 Silent rs7685698 4 185355556 [T/C] NM_002199 IRF2 Silent rs11723606 4 185359278 [T/C] NM_002199 IRF2 Silent rs13116389 4 185359416 [T/G] NM_002199 IRF2 Silent rs3775567 4 185361242 [T/C] NM_002199 IRF2 Silent rs793794 4 185363037 [A/G] NM_002199 IRF2 Silent rs7657540 4 185363829 [T/C] NM_002199 IRF2 Silent rs3775572 4 185369452 [A/G] NM_002199 IRF2 Silent rs3775574 4 185370066 [A/G] NM_002199 IRF2 Silent rs793806 4 185378160 [A/C] NM_002199 IRF2 Silent rs793803 4 185381055 [T/C] NM_002199 IRF2 Silent rs793798 4 185382061 [T/C] NM_002199 IRF2 Silent rs3775580 4 185383746 [T/C] NM_002199 IRF2 Silent rs3775582 4 185388487 [A/G] NM_002199 IRF2 Silent rs1863315 4 185395385 [T/C] NM_002199 IRF2 Silent rs1863314 4 185397811 [T/C] rs1059492 4 185398115 [A/C] rs7658103 4 185400748 [A/G] rs12172979 4 185406285 [T/C] rs7696696 4 185406638 [A/G] rs2014472 4 185412322 [A/G] rs17488695 4 185424289 [A/G] rs17585837 4 185425574 [T/C] rs6816265 4 185425853 [A/G] rs1077767 4 185434005 [T/C] NR_147158 LINC02427 Silent rs17585851 4 185434615 [T/C] NR_147158 LINC02427 Silent rs6849842 4 185436255 [A/G] NR_147158 LINC02427 Silent rs4862374 4 185436378 [A/G] NR_147158 LINC02427 Silent rs12646629 4 185440669 [A/G] NR_147158 LINC02427 Silent rs6552787 4 185449260 [T/C] NR_147158 LINC02427 Silent rs13111483 4 185458566 [A/G] NR_147158 LINC02427 Silent rs1918633 4 185461350 [A/G] rs6854047 4 185462993 [T/C] rs4862378 4 185467264 [T/C] rs10023706 4 185467652 [A/G] rs766908 4 185468885 [A/G] rs2059516 4 185469914 [T/C] rs28538637 4 185472199 [A/G] rs7655550 4 185473157 [A/G] rs4862379 4 185474558 [A/G] rs7682529 4 185477454 [A/G] rs965938 4 185481019 [A/G] rs6844313 4 185482878 [A/G] rs4862385 4 185490816 [T/C] rs10520563 4 185491838 [A/G] rs2114005 4 185496578 [A/G] rs6838378 4 185510238 [A/G] NR_131967 LINC02365 Silent rs1976955 4 185514341 [T/C] NR_131967 LINC02365 Silent rs3970313 4 185520068 [A/G] NR_131967 LINC02365 Silent rs12501768 4 185531158 [A/G] NR_131967 LINC02365 Silent rs2178094 4 185532342 [T/C] NR_131967 LINC02365 Silent rs7675251 4 185533691 [T/C] NR_131967 LINC02365 Silent rs4862396 4 185543672 [T/C] NR_131967,NR_131965,NR_131966 LINC02365,LINC02365,LINC02365 Silent,Silent,Silent rs1049253 4 185548951 [A/G] NM_032991,NM_004346,NM_001354777,NM_001354784,NM_001354779,NM_001354783,NM_001354781,NM_001354782,NM_001354780 CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs8549 4 185549008 [T/C] NM_032991,NM_004346,NM_001354777,NM_001354784,NM_001354779,NM_001354783,NM_001354781,NM_001354782,NM_001354780 CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4647698 4 185549217 [T/C] NM_032991,NM_004346,NM_001354777,NM_001354784,NM_001354779,NM_001354783,NM_001354781,NM_001354782,NM_001354780 CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4647694 4 185550122 [T/G] NM_032991,NM_004346,NM_001354777,NM_001354784,NM_001354779,NM_001354783,NM_001354781,NM_001354782,NM_001354780 CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1049210 4 185552225 [A/C] NM_032991,NM_004346,NM_001354777,NM_001354784,NM_001354779,NM_001354783,NM_001354781,NM_001354782,NM_001354780 CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3 EXON Missense_E190D,Missense_E190D,Missense_E190D,Silent,Missense_E164D,Silent,Silent,Silent,Missense_E164D rs2705897 4 185553098 [T/G] NM_032991,NM_004346,NM_001354777,NM_001354784,NM_001354779,NM_001354783,NM_001354781,NM_001354782,NM_001354780 CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2720376 4 185554300 [T/C] NM_032991,NM_004346,NM_001354777,NM_001354784,NM_001354779,NM_001354783,NM_001354781,NM_001354782,NM_001354780 CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2019978 4 185557581 [A/C] NM_032991,NM_004346,NM_001354777,NM_001354784,NM_001354779,NM_001354783,NM_001354781,NM_001354782,NM_001354780 CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4647610 4 185567931 [T/C] NM_032991,NM_004346,NM_001354777,NM_001354784,NM_001354779,NM_001354783,NM_001354781,NM_001354782,NM_001354780 CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4647603 4 185569730 [T/C] NM_032991,NM_004346,NM_001354777,NM_001354784,NM_001354779,NM_001354783,NM_001354781,NM_001354782,NM_001354780 CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3,CASP3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12108497 4 185571557 [T/C] NM_001345897,NM_001300768,NM_001345892,NM_001345891,NR_144314,NM_001345901,NM_001300767,NM_001345893,NM_001345900,NM_001345895,NM_001345898,NM_001345899,NM_001345894,NR_144312,NM_152683,NM_001345896,NR_144313 PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10011005 4 185581754 [A/G] NM_001345897,NM_001300768,NM_001345892,NM_001345891,NR_144314,NM_001345901,NM_001300767,NM_001345893,NM_001345900,NM_001345895,NM_001345898,NM_001345899,NM_001345894,NR_144312,NM_152683,NM_001345896,NR_144313 PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1405940 4 185591481 [T/C] NM_001345897,NM_001300768,NM_001345892,NM_001345891,NR_144314,NM_001345901,NM_001300767,NM_001345893,NM_001345900,NM_001345895,NM_001345898,NM_001345899,NM_001345894,NR_144312,NM_152683,NM_001345896,NR_144313 PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2696051 4 185604780 [T/G] NM_001345897,NM_001300768,NM_001345892,NM_001345891,NR_144314,NM_001345901,NM_001300767,NM_001345893,NM_001345900,NM_001345895,NM_001345898,NM_001345899,NM_001345894,NR_144312,NM_152683,NM_001345896,NR_144313 PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2178095 4 185609790 [A/G] NM_001345897,NM_001300768,NM_001345892,NM_001345891,NR_144314,NM_001345901,NM_001300767,NM_001345893,NM_001345900,NM_001345895,NM_001345898,NM_001345899,NM_001345894,NR_144312,NM_152683,NM_001345896,NR_144313 PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10013501 4 185614475 [T/C] NM_001345897,NM_001300768,NM_001345892,NM_001345891,NR_144314,NM_001345901,NM_001300767,NM_001345893,NM_001345900,NM_001345895,NM_001345898,NM_001345899,NM_001345894,NR_144312,NM_152683,NM_001345896,NR_144313 PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs14969 4 185615764 [A/C] NM_001345897,NM_001300768,NM_001345892,NM_001345891,NR_144314,NM_001345901,NM_001300767,NM_001345893,NM_001345900,NM_001345895,NM_001345898,NM_001345899,NM_001345894,NR_144312,NM_152683,NM_001345896,NR_144313,NM_024629,NR_104593 PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,CENPU,CENPU EXON Missense_T273K,Missense_T504K,Missense_T517K,Missense_T518K,Silent,Missense_T273K,Missense_T376K,Missense_T517K,Missense_T330K,Missense_T505K,Missense_T272K,Missense_T421K,Missense_T286K,Silent,Missense_T505K,Missense_T504K,Silent,Silent,Silent rs3184982 4 185615768 [T/G] NM_001345897,NM_001300768,NM_001345892,NM_001345891,NR_144314,NM_001345901,NM_001300767,NM_001345893,NM_001345900,NM_001345895,NM_001345898,NM_001345899,NM_001345894,NR_144312,NM_152683,NM_001345896,NR_144313,NM_024629,NR_104593 PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,PRIMPOL,CENPU,CENPU EXON Synonymous_G274G,Synonymous_G505G,Synonymous_G518G,Synonymous_G519G,Silent,Synonymous_G274G,Synonymous_G377G,Synonymous_G518G,Synonymous_G331G,Synonymous_G506G,Synonymous_G273G,Synonymous_G422G,Synonymous_G287G,Silent,Synonymous_G506G,Synonymous_G505G,Silent,Silent,Silent rs13478 4 185616438 [T/C] NM_024629,NR_104593 CENPU,CENPU EXON Silent,Silent rs6552804 4 185637699 [A/G] NM_024629,NR_104593 CENPU,CENPU EXON Missense_I157T,Silent rs2130392 4 185639169 [A/G] NM_024629,NR_104593 CENPU,CENPU Silent,Silent rs10025167 4 185649551 [A/C] NM_024629,NR_104593 CENPU,CENPU Silent,Silent rs6818447 4 185650154 [A/G] NM_024629,NR_104593 CENPU,CENPU EXON Synonymous_F44F,Silent rs1401357 4 185650821 [A/C] NM_024629,NR_104593 CENPU,CENPU Silent,Silent rs2871418 4 185654723 [T/C] NM_024629,NR_104593 CENPU,CENPU Silent,Silent rs6851816 4 185654837 [T/C] NM_024629,NR_104593 CENPU,CENPU Silent,Silent rs7699623 4 185655676 [T/C] rs4862411 4 185664774 [T/C] rs12513029 4 185665118 [A/G] rs2171838 4 185667404 [T/C] rs7676174 4 185667887 [T/C] rs755535 4 185668375 [A/G] rs11934173 4 185674313 [A/C] rs12644905 4 185676683 [T/C] rs1056896 4 185677363 [T/C] NM_001286710,NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1,ACSL1 EXON Silent,Silent,Silent,Silent,Silent rs8086 4 185677421 [T/C] NM_001286710,NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1,ACSL1 EXON Silent,Silent,Silent,Silent,Silent rs2292899 4 185678110 [A/G] NM_001286710,NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1,ACSL1 EXON Silent,Silent,Silent,Silent,Silent rs3749233 4 185687233 [T/C] NM_001286710,NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1,ACSL1 Silent,Silent,Silent,Silent,Silent rs3749232 4 185687373 [A/C] NM_001286710,NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1,ACSL1 Silent,Silent,Silent,Silent,Silent rs4862415 4 185688754 [T/C] NM_001286710,NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1,ACSL1 Silent,Silent,Silent,Silent,Silent rs4862417 4 185690601 [A/G] NM_001286710,NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1,ACSL1 Silent,Silent,Silent,Silent,Silent rs7691972 4 185694697 [A/G] NM_001286710,NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1,ACSL1 Silent,Silent,Silent,Silent,Silent rs4069938 4 185700776 [T/G] NM_001286710,NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1,ACSL1 Silent,Silent,Silent,Silent,Silent rs1803898 4 185701549 [T/G] NM_001286710,NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1,ACSL1 EXON Synonymous_I138I,Synonymous_I138I,Synonymous_I138I,Silent,Silent rs2102862 4 185705006 [A/G] NM_001286710,NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1,ACSL1 Silent,Silent,Silent,Silent,Silent rs7681334 4 185710859 [A/G] NM_001286710,NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1,ACSL1 Silent,Silent,Silent,Silent,Silent rs11132255 4 185718727 [A/G] NM_001286710,NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1,ACSL1 Silent,Silent,Silent,Silent,Silent rs6552828 4 185725416 [A/G] NM_001286710,NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1,ACSL1 Silent,Silent,Silent,Silent,Silent rs902177 4 185728839 [T/C] NM_001995,NM_001286708,NM_001286711,NM_001286712 ACSL1,ACSL1,ACSL1,ACSL1 Silent,Silent,Silent,Silent rs13120078 4 185731442 [A/G] NM_001995,NM_001286708,NM_001286711 ACSL1,ACSL1,ACSL1 Silent,Silent,Silent rs9997745 4 185737843 [A/G] NM_001995,NM_001286711 ACSL1,ACSL1 Silent,Silent rs1554336 4 185744820 [T/C] NM_001995,NM_001286711 ACSL1,ACSL1 Silent,Silent rs12503643 4 185746088 [T/G] NM_001995,NM_001286711 ACSL1,ACSL1 Silent,Silent rs10027540 4 185750840 [A/G] rs10033885 4 185753007 [A/C] rs6827693 4 185755328 [T/G] rs4862428 4 185767176 [A/G] NR_132989 MIR3945HG Silent rs4862432 4 185771979 [A/G] NR_132989 MIR3945HG Silent rs6852527 4 185772925 [A/G] NR_132989 MIR3945HG Silent rs6552833 4 185773528 [A/G] NR_132989 MIR3945HG Silent rs13144344 4 185776616 [A/G] NR_132989 MIR3945HG Silent rs12650715 4 185776850 [A/G] rs4862439 4 185781300 [T/C] rs13142179 4 185781717 [T/C] rs4862448 4 185788486 [T/C] rs4862450 4 185788762 [T/G] rs4862451 4 185789995 [A/G] rs7670324 4 185791901 [T/C] rs6853755 4 185801346 [T/C] rs13434707 4 185801567 [A/G] rs11734276 4 185802696 [T/C] rs11723505 4 185804364 [T/C] rs11736582 4 185804494 [A/G] rs6832271 4 185805191 [T/C] rs13143841 4 185808270 [T/G] rs6822813 4 185808934 [T/C] rs6849202 4 185809272 [T/C] rs6828840 4 185809643 [A/G] rs6835984 4 185810760 [A/G] rs4862455 4 185821036 [A/G] rs6552840 4 185828677 [A/G] rs4392546 4 185830781 [T/C] rs4496623 4 185835029 [A/G] rs10005243 4 185845735 [A/G] rs6835458 4 185847793 [A/G] rs4318691 4 185848004 [T/C] rs10001154 4 185849906 [T/C] rs7682801 4 185853636 [A/G] rs10446837 4 185859682 [A/G] rs12641377 4 185861258 [A/G] rs4862466 4 185864741 [T/C] rs4370185 4 185869216 [T/C] rs6830291 4 185870383 [T/C] rs9992806 4 185872178 [A/G] rs12502026 4 185874623 [A/G] rs4861647 4 185874675 [T/C] rs11734892 4 185875614 [A/G] rs6822322 4 185876135 [T/C] rs6822805 4 185876473 [A/G] rs6854741 4 185877029 [T/G] rs13143382 4 185877443 [A/G] rs6419946 4 185882454 [T/G] rs10866272 4 185884206 [A/G] rs4355430 4 185885897 [T/C] rs9993348 4 185894655 [A/G] rs10866273 4 185905754 [A/G] rs6843954 4 185907334 [A/G] rs4862478 4 185907997 [A/G] rs6820983 4 185916343 [T/C] rs11132270 4 185925922 [A/C] rs11722349 4 185928446 [T/C] rs4631092 4 185928896 [T/G] rs7664096 4 185929997 [T/C] rs16813 4 185930269 [T/C] rs1486664 4 185935020 [A/G] rs13119549 4 185935259 [T/C] rs901434 4 185941196 [A/G] NM_001300782,NM_001300781 HELT,HELT Silent,Silent rs11727431 4 185943413 [T/C] rs6854448 4 185943856 [A/G] rs6851788 4 185946538 [T/C] rs752632 4 185957817 [T/C] rs1012518 4 185965017 [T/C] rs4862495 4 185973097 [A/C] NR_147059 LINC02436 Silent rs728756 4 185977068 [T/G] NR_147059 LINC02436 Silent rs4415003 4 185977226 [T/C] NR_147059 LINC02436 Silent rs4577622 4 185977354 [T/C] NR_147059 LINC02436 Silent rs6852910 4 185979170 [A/G] NR_147059 LINC02436 Silent rs6853461 4 185979298 [T/C] NR_147059 LINC02436 Silent rs6844558 4 185981436 [T/C] NR_147059 LINC02436 Silent rs4861655 4 185983220 [A/G] NR_147059 LINC02436 Silent rs4862499 4 185997791 [A/G] NR_147059 LINC02436 Silent rs10023344 4 185999348 [T/C] NR_147059 LINC02436 Silent rs6819903 4 186003688 [A/C] NR_147059 LINC02436 Silent rs4862502 4 186007879 [A/G] NR_147059 LINC02436 Silent rs4861656 4 186008402 [T/C] NR_147059 LINC02436 Silent rs1545951 4 186012601 [T/C] NR_147059 LINC02436 Silent rs11132275 4 186013276 [A/G] NR_147059 LINC02436 Silent rs7667259 4 186016584 [T/C] NR_147059 LINC02436 Silent rs13120719 4 186019565 [T/C] NR_147059 LINC02436 Silent rs13121592 4 186019962 [A/C] NR_147059 LINC02436 Silent rs2310156 4 186022884 [T/C] NR_147059 LINC02436 Silent rs12512707 4 186026909 [T/C] NR_147059 LINC02436 Silent rs11132277 4 186027524 [T/C] NR_147059 LINC02436 Silent rs2310155 4 186029032 [A/C] rs6552864 4 186031823 [A/G] rs1872719 4 186034134 [A/G] rs3912538 4 186037329 [A/G] rs7661225 4 186038657 [A/G] rs9884823 4 186038842 [A/G] rs10026207 4 186039201 [A/C] rs6853087 4 186044138 [T/C] rs10002793 4 186045532 [T/C] rs1486668 4 186045738 [A/G] rs6818704 4 186046473 [A/G] rs28678870 4 186055546 [T/C] rs12506141 4 186059893 [T/C] rs28442214 4 186060360 [T/C] rs10024068 4 186063341 [A/G] rs3733653 4 186069917 [A/C] NM_001151 SLC25A4 EXON Silent rs2046535 4 186070432 [T/C] NM_001151 SLC25A4 EXON Silent rs7675110 4 186071068 [A/G] NM_001151 SLC25A4 EXON Silent rs11729551 4 186071932 [A/G] rs11729626 4 186072110 [A/G] rs13145878 4 186078324 [T/C] rs6850094 4 186086046 [T/C] NM_020827 CFAP97 Silent rs6839413 4 186090818 [T/C] NM_020827,NM_001292033 CFAP97,CFAP97 EXON Silent,Silent rs6814673 4 186091191 [T/C] NM_020827,NM_001292033 CFAP97,CFAP97 EXON Silent,Silent rs6855305 4 186097045 [T/C] NM_020827,NM_001292033 CFAP97,CFAP97 EXON Synonymous_P405P,Synonymous_P405P rs1133657 4 186111639 [T/C] NM_020827,NM_001292033 CFAP97,CFAP97 EXON Missense_T238A,Missense_T238A rs3108237 4 186112111 [A/G] NM_020827,NM_001292033 CFAP97,CFAP97 EXON Synonymous_P80P,Synonymous_P80P rs1534140 4 186117162 [T/C] NM_020827,NM_001292033 CFAP97,CFAP97 Silent,Silent rs3108244 4 186125842 [A/G] NM_001317781 SNX25 Silent rs2177796 4 186131934 [T/G] NM_001317781 SNX25 Silent rs2310159 4 186134204 [A/G] NM_001317781 SNX25 Silent rs3112898 4 186142979 [T/C] NM_001317781 SNX25 Silent rs7675903 4 186159445 [A/C] NM_001317781 SNX25 Silent rs7698980 4 186175197 [A/G] NM_001317781 SNX25 Silent rs3112854 4 186175566 [A/G] NM_001317781 SNX25 Silent rs3108227 4 186178278 [T/G] NM_001317781 SNX25 Silent rs2280665 4 186185293 [A/G] NM_001317781 SNX25 Silent rs7672656 4 186189511 [T/C] NM_001317781 SNX25 Silent rs3108224 4 186196453 [A/G] NM_001317781 SNX25 Silent rs1534146 4 186197070 [T/C] NM_001317781 SNX25 Silent rs2692596 4 186204090 [T/C] NM_001317781 SNX25 Silent rs12641710 4 186205791 [T/C] NM_001317781 SNX25 Silent rs11725533 4 186209273 [A/G] NM_001317781 SNX25 Silent rs1288547 4 186216136 [A/G] NM_001317781 SNX25 Silent rs1288569 4 186230276 [T/C] NM_001317781 SNX25 Silent rs10000719 4 186242233 [T/C] NM_001317781 SNX25 Silent rs1288572 4 186252138 [T/C] NM_001317781 SNX25 Silent rs3733644 4 186254126 [A/G] NM_001317781 SNX25 Silent rs3756275 4 186267751 [A/G] NM_001317781 SNX25 EXON Missense_I586V rs10000918 4 186268576 [A/G] NM_001317781 SNX25 Silent rs10030392 4 186271154 [A/G] NM_001317781 SNX25 Silent rs3822302 4 186272773 [T/C] NM_001317781 SNX25 Silent rs1031128 4 186281755 [T/C] NM_001317781 SNX25 Silent rs7664573 4 186288846 [T/G] NM_018409 LRP2BP Silent rs4862522 4 186292169 [T/C] NM_018409 LRP2BP Silent rs3756276 4 186292826 [A/C] NM_018409 LRP2BP Silent rs3797026 4 186294198 [T/C] NM_018409 LRP2BP EXON Synonymous_G205G rs1288549 4 186299519 [A/C] NM_018409 LRP2BP EXON Silent rs3797032 4 186299656 [A/G] NM_018409 LRP2BP EXON Silent rs10018215 4 186302406 [T/G] rs11944575 4 186304749 [A/G] rs6818425 4 186309757 [T/C] rs6845326 4 186313557 [A/G] rs4862523 4 186316633 [A/G] rs4862524 4 186316829 [A/G] rs1443903 4 186322002 [T/G] NR_144317,NM_018359,NR_028085 UFSP2,UFSP2,UFSP2 Silent,Silent,Silent rs6815168 4 186325429 [T/C] NR_144317,NM_018359,NR_028085 UFSP2,UFSP2,UFSP2 Silent,Silent,Silent rs2289722 4 186336465 [T/C] NR_144317,NM_018359,NR_028085 UFSP2,UFSP2,UFSP2 EXON Silent,Synonymous_Q176Q,Silent rs10032989 4 186336583 [A/G] NR_144317,NM_018359,NR_028085 UFSP2,UFSP2,UFSP2 Silent,Silent,Silent rs2028701 4 186346239 [A/C] NR_144317,NM_018359,NR_028085 UFSP2,UFSP2,UFSP2 Silent,Silent,Silent rs12500107 4 186350063 [T/C] rs11934546 4 186351612 [T/C] NM_001346007,NM_001114357 C4orf47,C4orf47 Silent,Silent rs7672394 4 186353670 [T/G] NM_001346007,NM_001114357 C4orf47,C4orf47 Silent,Silent rs7697970 4 186357523 [C/G] NM_001346007,NM_001114357 C4orf47,C4orf47 Silent,Silent rs12650364 4 186365998 [A/G] NM_001346007,NM_001114357 C4orf47,C4orf47 Silent,Silent rs11737048 4 186366615 [T/G] NM_001346007,NM_001114357,NM_152775,NM_001145411 C4orf47,C4orf47,CCDC110,CCDC110 EXON Silent,Silent,Silent,Silent rs6838700 4 186372826 [A/C] NM_152775,NM_001145411 CCDC110,CCDC110 Silent,Silent rs13102235 4 186373316 [A/G] NM_152775,NM_001145411 CCDC110,CCDC110 Silent,Silent rs10022110 4 186375488 [A/G] NM_152775,NM_001145411 CCDC110,CCDC110 Silent,Silent rs4279261 4 186378790 [T/C] NM_152775,NM_001145411 CCDC110,CCDC110 Silent,Silent rs6827370 4 186379735 [T/C] NM_152775,NM_001145411 CCDC110,CCDC110 EXON Missense_Q669R,Missense_Q632R rs11132306 4 186380515 [A/G] NM_152775,NM_001145411 CCDC110,CCDC110 EXON Missense_S409F,Missense_S372F rs7699687 4 186381115 [T/G] NM_152775,NM_001145411 CCDC110,CCDC110 EXON Missense_P209Q,Missense_P172Q rs11132309 4 186382206 [A/G] NM_152775,NM_001145411 CCDC110,CCDC110 EXON Synonymous_D115D,Silent rs4862534 4 186383240 [T/G] NM_152775,NM_001145411 CCDC110,CCDC110 Silent,Silent rs4314326 4 186383415 [T/C] NM_152775,NM_001145411 CCDC110,CCDC110 Silent,Silent rs6849514 4 186386587 [T/C] NM_152775,NM_001145411 CCDC110,CCDC110 Silent,Silent rs6857096 4 186388073 [A/G] NM_152775,NM_001145411 CCDC110,CCDC110 Silent,Silent rs9998424 4 186390753 [A/G] NM_152775,NM_001145411 CCDC110,CCDC110 Silent,Silent rs4862535 4 186397351 [A/C] rs4241798 4 186400228 [T/C] rs6846185 4 186401713 [T/C] rs1385581 4 186414626 [A/G] rs4635850 4 186423637 [A/G] NM_001114107,NM_014476,NM_001257962,NR_047562,NM_001257963 PDLIM3,PDLIM3,PDLIM3,PDLIM3,PDLIM3 EXON Synonymous_V254V,Synonymous_V302V,Synonymous_V214V,Silent,Synonymous_V135V rs12644280 4 186423655 [A/G] NM_001114107,NM_014476,NM_001257962,NR_047562,NM_001257963 PDLIM3,PDLIM3,PDLIM3,PDLIM3,PDLIM3 Silent,Silent,Silent,Silent,Silent rs6552886 4 186424667 [A/G] NM_001114107,NM_014476,NM_001257962,NR_047562,NM_001257963 PDLIM3,PDLIM3,PDLIM3,PDLIM3,PDLIM3 Silent,Silent,Silent,Silent,Silent rs11937705 4 186429897 [T/C] NM_001114107,NM_014476,NM_001257962,NR_047562,NM_001257963 PDLIM3,PDLIM3,PDLIM3,PDLIM3,PDLIM3 Silent,Silent,Silent,Silent,Silent rs10446841 4 186430436 [A/G] NM_001114107,NM_014476,NM_001257962,NR_047562,NM_001257963 PDLIM3,PDLIM3,PDLIM3,PDLIM3,PDLIM3 Silent,Silent,Silent,Silent,Silent rs7691287 4 186448369 [T/C] NM_001114107,NM_014476,NM_001257962,NR_047562,NM_001257963 PDLIM3,PDLIM3,PDLIM3,PDLIM3,PDLIM3 Silent,Silent,Silent,Silent,Silent rs3792700 4 186449651 [A/G] NM_001114107,NM_014476,NM_001257962,NR_047562,NM_001257963 PDLIM3,PDLIM3,PDLIM3,PDLIM3,PDLIM3 Silent,Silent,Silent,Silent,Silent rs3762920 4 186459026 [A/G] rs2310322 4 186467147 [A/G] rs7680845 4 186467810 [A/G] rs11132321 4 186468992 [A/G] rs1158465 4 186469493 [A/G] rs12649063 4 186470421 [T/C] rs931305 4 186474700 [A/G] rs11935679 4 186483220 [A/G] rs11132328 4 186485293 [A/G] rs10050296 4 186488443 [T/G] rs13102445 4 186488834 [T/C] rs10003413 4 186489396 [T/G] rs10866278 4 186499546 [T/C] rs2310320 4 186501965 [T/C] rs1872445 4 186504058 [T/C] rs13123635 4 186504441 [A/G] rs6823490 4 186506165 [A/C] rs10009018 4 186507021 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1046236 4 186507187 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7674108 4 186507280 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10031753 4 186507409 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6854874 4 186512433 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9991125 4 186518902 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6823956 4 186519992 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10012577 4 186522043 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6818789 4 186522953 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10049785 4 186523612 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4861672 4 186524787 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2171046 4 186525914 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13144963 4 186528433 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12503636 4 186529468 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10008758 4 186529560 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9312336 4 186531693 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10019065 4 186533350 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10002478 4 186534984 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12502295 4 186535247 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13144235 4 186537232 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10026821 4 186540503 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10030246 4 186541887 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13435845 4 186542593 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13119106 4 186545719 [T/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10006389 4 186550283 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1471794 4 186551624 [T/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13138440 4 186553480 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1471795 4 186555742 [T/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13144135 4 186558150 [T/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3816807 4 186558860 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2306707 4 186559109 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4862556 4 186563188 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3736194 4 186566987 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7663196 4 186570521 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6821894 4 186571441 [T/C] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6848934 4 186575288 [A/G] NM_001145673,NM_003603,NM_001270771,NM_001145675,NM_021069,NM_001145671,NM_001145670,NM_001145674,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11934819 4 186579041 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4241809 4 186581859 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1021217 4 186584255 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6822552 4 186586768 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9312338 4 186589959 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7686233 4 186590237 [T/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4599460 4 186593410 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4862559 4 186593672 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4340826 4 186594332 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13140168 4 186597950 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4862562 4 186602210 [A/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7653904 4 186607977 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11132333 4 186608071 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13150700 4 186610123 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6823546 4 186611663 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12512174 4 186612732 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7687550 4 186615022 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10434304 4 186615500 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12507995 4 186616234 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs955264 4 186618175 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs955263 4 186618304 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1547909 4 186622179 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs904451 4 186630946 [A/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6825114 4 186636564 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11132340 4 186638655 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4862566 4 186641002 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13131324 4 186641213 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10017683 4 186641563 [T/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11736488 4 186642895 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10011292 4 186648646 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12650192 4 186650946 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3796644 4 186652292 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs950590 4 186654377 [T/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2276911 4 186658094 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7669883 4 186660076 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1027521 4 186661203 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7667992 4 186663336 [T/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs904448 4 186663425 [A/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7679506 4 186664542 [T/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7678763 4 186670089 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7654366 4 186670339 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2173479 4 186671479 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12503317 4 186671599 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10027307 4 186674804 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4543173 4 186677253 [A/G] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1039237 4 186688767 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7655720 4 186692629 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7693361 4 186694576 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4487396 4 186695208 [T/C] NM_001145673,NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2310357 4 186697494 [T/C] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs12640132 4 186698737 [T/C] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs10028428 4 186699584 [T/C] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs979922 4 186701046 [T/G] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs6830250 4 186707604 [T/C] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs6858040 4 186710312 [A/G] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs4862571 4 186714004 [A/C] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs7684943 4 186715008 [A/G] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs13146524 4 186716550 [T/C] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs10021308 4 186716984 [A/G] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs9998709 4 186717043 [A/G] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs13126725 4 186717589 [A/G] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs1995193 4 186719815 [A/G] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs4861680 4 186721885 [A/G] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs11132349 4 186722819 [T/C] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs11132350 4 186725449 [T/G] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs878357 4 186730448 [T/C] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs4861681 4 186731313 [T/C] NM_003603,NM_001270771,NM_021069,NM_001145671,NM_001145670,NM_001145672 SORBS2,SORBS2,SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent,Silent,Silent rs1566347 4 186732566 [T/C] NM_003603,NM_001270771,NM_021069,NM_001145670 SORBS2,SORBS2,SORBS2,SORBS2 Silent,Silent,Silent,Silent rs6858186 4 186734480 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs12502302 4 186735780 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs7673778 4 186738016 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs4861682 4 186739072 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs13132552 4 186744774 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs13112696 4 186745734 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs11732469 4 186746561 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs1039238 4 186746956 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs11132355 4 186747070 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs6814512 4 186747694 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs13111004 4 186751133 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs4862577 4 186751341 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs9994285 4 186758065 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs10028944 4 186760232 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs7674180 4 186760957 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs1499010 4 186761638 [A/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs7694456 4 186764476 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs11724690 4 186764747 [T/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs6552928 4 186769051 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs6848278 4 186775572 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs1566355 4 186776464 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs10020233 4 186782009 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs2648126 4 186782291 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs2648117 4 186787096 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs11940126 4 186790909 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs2648112 4 186791290 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs2648111 4 186791524 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs4862580 4 186793887 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs4861688 4 186794072 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs7679935 4 186796587 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs10002028 4 186796912 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs11721899 4 186799239 [T/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs9994907 4 186800037 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs4343763 4 186801590 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs13132627 4 186802492 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs6552934 4 186807834 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs4862585 4 186809714 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs4862586 4 186809838 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs10031442 4 186816480 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs7693781 4 186821893 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs12641600 4 186839888 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs7680928 4 186840924 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs7656290 4 186840968 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs7656287 4 186840999 [A/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs13140248 4 186842789 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs2034787 4 186843924 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs4862596 4 186846999 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs7687824 4 186851062 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs6552938 4 186855364 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs10033624 4 186861791 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs10866286 4 186866070 [T/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs959585 4 186868062 [A/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs1551438 4 186872505 [A/G] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs1031505 4 186873844 [A/C] NM_001270771,NM_021069 SORBS2,SORBS2 Silent,Silent rs959621 4 186881436 [A/G] rs959622 4 186881570 [A/C] rs7694098 4 186881988 [T/G] rs10155470 4 186882290 [T/C] rs1454746 4 186884336 [A/G] rs830829 4 186893350 [T/G] rs7676342 4 186901587 [A/G] rs4862611 4 186902860 [T/C] rs4862612 4 186903129 [T/C] rs11724833 4 186910924 [T/C] rs830838 4 186913109 [T/C] rs7681323 4 186915297 [A/G] rs6852642 4 186917039 [A/G] rs830841 4 186917269 [T/C] rs830842 4 186917931 [T/C] rs13113778 4 186921897 [A/G] rs2049044 4 186923601 [T/C] rs11132376 4 186928529 [T/C] rs713542 4 186929424 [A/C] rs2008461 4 186929646 [T/G] rs2603731 4 186932780 [T/C] rs7679967 4 186935500 [T/C] rs12643213 4 186942380 [A/G] rs1401573 4 186943462 [T/C] rs6815342 4 186944931 [T/C] rs12648771 4 186953813 [T/C] rs11725282 4 186957112 [T/C] rs6814242 4 186959365 [A/G] rs10029377 4 186960627 [T/C] rs9996894 4 186961015 [T/C] rs7699825 4 186961525 [T/C] rs7691384 4 186972741 [T/C] rs7678294 4 186979699 [A/G] rs956239 4 186983342 [T/C] rs5743305 4 186989333 [T/A] rs5743309 4 186990345 [A/C] NM_003265 TLR3 EXON Silent rs11721827 4 186991137 [A/C] NM_003265 TLR3 Silent rs7657186 4 186994039 [A/G] NM_003265 TLR3 Silent rs13126816 4 186994178 [A/G] NM_003265 TLR3 Silent rs3775296 4 186997767 [A/C] NM_003265 TLR3 EXON Silent rs3775291 4 187004074 [T/C] NM_003265 TLR3 EXON Missense_L412F rs10025405 4 187006806 [A/G] rs4862633 4 187009972 [T/C] rs4608848 4 187010104 [T/C] rs6857595 4 187011126 [T/C] rs1519309 4 187015089 [T/C] rs6848963 4 187016610 [A/C] rs1983369 4 187019433 [T/C] rs9312342 4 187021315 [T/C] rs1401570 4 187029821 [T/G] rs1715052 4 187038546 [A/G] rs1715051 4 187038801 [T/G] rs7665411 4 187042798 [T/G] rs10030678 4 187043908 [A/G] rs1706145 4 187044161 [T/G] rs9998530 4 187047812 [A/G] rs7656677 4 187054136 [T/C] rs4862644 4 187057812 [T/C] rs13105400 4 187059563 [T/G] rs7660462 4 187059719 [T/C] rs7660915 4 187060065 [A/C] rs7668227 4 187061084 [A/G] rs13141920 4 187064553 [T/G] rs7684126 4 187072383 [T/C] NM_001006655,NM_001350178,NM_001350179,NM_015398 FAM149A,FAM149A,FAM149A,FAM149A Silent,Silent,Silent,Silent rs2276914 4 187072932 [A/G] NM_001006655,NM_001350178,NM_001350179,NM_015398 FAM149A,FAM149A,FAM149A,FAM149A Silent,Silent,Silent,Silent rs4862650 4 187074833 [A/G] NM_001006655,NM_001350178,NM_001350179,NM_015398 FAM149A,FAM149A,FAM149A,FAM149A EXON Missense_K41E,Missense_K41E,Missense_K41E,Missense_K41E rs4862652 4 187076793 [A/G] NM_001006655,NM_001350178,NM_001350179,NM_015398 FAM149A,FAM149A,FAM149A,FAM149A Silent,Silent,Silent,Silent rs4862653 4 187077206 [A/G] NM_001006655,NM_001350178,NM_001350179,NM_015398 FAM149A,FAM149A,FAM149A,FAM149A EXON Missense_K146E,Missense_K146E,Missense_K146E,Missense_K146E rs2276924 4 187078785 [A/G] NM_001006655,NM_001350178,NM_001350179,NM_015398 FAM149A,FAM149A,FAM149A,FAM149A EXON Missense_H214R,Missense_H214R,Missense_H214R,Missense_H214R rs2276920 4 187078938 [A/G] NM_001006655,NM_001350178,NM_001350179,NM_015398 FAM149A,FAM149A,FAM149A,FAM149A Silent,Silent,Silent,Silent rs1877321 4 187079017 [A/G] NM_001006655,NM_001350178,NM_001350179,NM_015398 FAM149A,FAM149A,FAM149A,FAM149A Silent,Silent,Silent,Silent rs13141433 4 187079384 [T/C] NM_001006655,NM_001350178,NM_001350179,NM_015398 FAM149A,FAM149A,FAM149A,FAM149A Silent,Silent,Silent,Silent rs6818265 4 187088410 [T/G] NM_001006655,NM_001350178,NM_001350179,NM_015398 FAM149A,FAM149A,FAM149A,FAM149A EXON Missense_L457V,Missense_L456V,Missense_L456V,Missense_L457V rs2036912 4 187099043 [A/G] rs4862658 4 187099609 [A/G] rs6816903 4 187100384 [T/C] rs10027488 4 187107849 [A/G] rs7689823 4 187109866 [A/G] rs1877319 4 187110782 [A/G] NR_046264 FLJ38576 EXON Silent rs10866290 4 187114479 [T/C] NM_207352 CYP4V2 Silent rs7684025 4 187116227 [A/G] NM_207352 CYP4V2 Silent rs4862662 4 187118662 [T/G] NM_207352 CYP4V2 Silent rs13146272 4 187120211 [A/C] NM_207352 CYP4V2 EXON Missense_Q259K rs7687961 4 187122009 [A/C] NM_207352 CYP4V2 Silent rs3736455 4 187122319 [T/G] NM_207352 CYP4V2 EXON Synonymous_A270A rs3736456 4 187122355 [T/C] NM_207352 CYP4V2 EXON Synonymous_C282C rs10029149 4 187126449 [T/C] NM_207352 CYP4V2 EXON Synonymous_D361D rs1473597 4 187127817 [A/G] NM_207352 CYP4V2 Silent rs2102575 4 187131504 [A/G] NM_207352 CYP4V2 Silent rs6842047 4 187133576 [A/C] NM_207352 CYP4V2 EXON Silent rs1511800 4 187135556 [T/C] rs4253236 4 187148071 [T/C] rs4253238 4 187148387 [T/C] rs4253239 4 187148475 [T/C] rs1912826 4 187149540 [A/G] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 Silent,Silent,Silent rs1511802 4 187150806 [T/C] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 Silent,Silent,Silent rs4253351 4 187159600 [A/G] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 Silent,Silent,Silent rs4253259 4 187162048 [T/G] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 Silent,Silent,Silent rs4253292 4 187168866 [A/G] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 Silent,Silent,Silent rs4253373 4 187171404 [A/C] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 EXON Missense_H202Q,Missense_H164Q,Silent rs2278542 4 187171427 [A/C] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 EXON Missense_A210E,Missense_A172E,Silent rs4253301 4 187173012 [T/G] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 EXON Missense_S381A,Missense_S343A,Missense_S179A rs4253308 4 187174363 [A/C] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 Silent,Silent,Silent rs4253315 4 187175457 [T/C] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 Silent,Silent,Silent rs4253316 4 187175753 [A/C] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 EXON Missense_Q442P,Missense_Q404P,Missense_Q240P rs3775302 4 187177814 [A/G] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 Silent,Silent,Silent rs4253325 4 187178473 [A/G] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 EXON Missense_R560Q,Silent,Missense_R358Q rs925453 4 187179210 [T/C] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 EXON Synonymous_N587N,Missense_W503R,Synonymous_N385N rs3087505 4 187179486 [A/G] NM_000892,NM_001318394,NM_001318396 KLKB1,KLKB1,KLKB1 EXON Silent,Silent,Silent rs3756009 4 187186111 [A/G] rs3822056 4 187187005 [T/G] rs3733403 4 187187135 [C/G] NM_001354804,NM_000128 F11,F11 EXON Silent,Silent rs925451 4 187187569 [A/G] NM_001354804,NM_000128 F11,F11 Silent,Silent rs4253405 4 187190810 [A/G] NM_001354804,NM_000128 F11,F11 Silent,Silent rs2036914 4 187192481 [T/C] NM_001354804,NM_000128 F11,F11 Silent,Silent rs4253840 4 187196760 [T/C] NM_000128 F11 Silent rs4253418 4 187199497 [A/G] NM_000128 F11 Silent rs4253419 4 187199888 [A/G] NM_000128 F11 Silent rs2241817 4 187201001 [A/G] NM_000128 F11 Silent rs5974 4 187201211 [A/G] NM_000128 F11 EXON Synonymous_T267T rs5967 4 187201527 [T/G] NM_000128 F11 EXON Missense_C339F rs4253421 4 187204937 [A/G] NM_000128 F11 Silent rs5970 4 187205301 [T/C] NM_000128 F11 EXON Synonymous_G397G rs4253426 4 187206783 [T/G] NM_000128 F11 Silent rs2289252 4 187207381 [T/C] NM_000128,NR_033900 F11,F11-AS1 EXON Silent,Silent rs5975 4 187208968 [T/C] NM_000128,NR_033900 F11,F11-AS1 EXON Synonymous_D569D,Silent rs5966 4 187209559 [A/G] NM_000128,NR_033900 F11,F11-AS1 Silent,Silent rs5971 4 187209702 [T/G] NM_000128,NR_033900 F11,F11-AS1 EXON Synonymous_R604R,Silent rs5976 4 187209729 [A/G] NM_000128,NR_033900 F11,F11-AS1 EXON Synonymous_E613E,Silent rs4253429 4 187210033 [A/G] NM_000128,NR_033900 F11,F11-AS1 EXON Silent,Silent rs4253430 4 187210064 [C/G] NM_000128,NR_033900 F11,F11-AS1 EXON Silent,Silent rs4253865 4 187210090 [A/G] NM_000128,NR_033900 F11,F11-AS1 EXON Silent,Silent rs1062547 4 187210247 [A/T] NM_000128,NR_033900 F11,F11-AS1 EXON Silent,Silent rs4253431 4 187210620 [A/G] NM_000128,NR_033900 F11,F11-AS1 EXON Silent,Silent rs11938564 4 187212134 [T/G] NR_033900 F11-AS1 EXON Silent rs6843926 4 187213027 [T/C] NR_033900 F11-AS1 Silent rs13145616 4 187215016 [A/C] NR_033900 F11-AS1 Silent rs13136269 4 187217008 [T/C] NR_033900 F11-AS1 Silent rs12507040 4 187217373 [A/G] NR_033900 F11-AS1 Silent rs12511874 4 187217560 [T/C] NR_033900 F11-AS1 Silent rs4572916 4 187223583 [A/C] NR_033900 F11-AS1 Silent rs1008728 4 187226673 [T/C] NR_033900 F11-AS1 Silent rs13133050 4 187230737 [A/C] NR_033900 F11-AS1 Silent rs12331264 4 187233838 [T/C] NR_033900 F11-AS1 Silent rs6854650 4 187235953 [T/C] NR_033900 F11-AS1 Silent rs10020303 4 187235998 [A/G] NR_033900 F11-AS1 Silent rs6839415 4 187237305 [T/C] NR_033900 F11-AS1 Silent rs6552971 4 187238388 [A/G] NR_033900 F11-AS1 Silent rs6552972 4 187238404 [T/C] NR_033900 F11-AS1 Silent rs7687352 4 187239747 [A/G] NR_033900 F11-AS1 Silent rs9993749 4 187239849 [T/G] NR_033900 F11-AS1 Silent rs7700014 4 187241497 [T/C] NR_033900 F11-AS1 Silent rs7349633 4 187247089 [T/G] NR_033900 F11-AS1 Silent rs11132389 4 187251860 [A/G] NR_033900 F11-AS1 Silent rs6829128 4 187257004 [T/C] NR_033900 F11-AS1 Silent rs13148903 4 187257576 [A/G] NR_033900 F11-AS1 Silent rs13150348 4 187258118 [T/C] NR_033900 F11-AS1 Silent rs10032695 4 187262489 [T/G] NR_033900 F11-AS1 Silent rs4861710 4 187263675 [T/C] NR_033900 F11-AS1 Silent rs12331550 4 187264414 [A/G] NR_033900 F11-AS1 Silent rs7672650 4 187271047 [T/C] NR_033900 F11-AS1 Silent rs10020635 4 187280138 [T/C] NR_033900 F11-AS1 Silent rs9918008 4 187282857 [A/G] NR_033900 F11-AS1 Silent rs11132390 4 187283915 [T/C] NR_033900 F11-AS1 Silent rs6816112 4 187285215 [A/G] NR_033900 F11-AS1 Silent rs1901314 4 187286307 [T/C] NR_033900 F11-AS1 Silent rs1868893 4 187287475 [T/C] NR_033900 F11-AS1 Silent rs4862682 4 187289668 [A/G] NR_033900 F11-AS1 Silent rs10014510 4 187292020 [A/G] NR_033900 F11-AS1 Silent rs9997314 4 187297232 [T/C] NR_033900 F11-AS1 Silent rs4862684 4 187299297 [A/G] NR_033900 F11-AS1 Silent rs4862687 4 187301857 [A/G] NR_033900 F11-AS1 Silent rs6817039 4 187313377 [A/G] NR_033900 F11-AS1 Silent rs12331403 4 187314751 [A/G] NR_033900 F11-AS1 Silent rs2889188 4 187315811 [A/G] NR_033900 F11-AS1 Silent rs10018544 4 187318091 [A/G] NR_033900 F11-AS1 Silent rs2167370 4 187329245 [T/C] NR_033900 F11-AS1 Silent rs6842991 4 187330513 [T/C] NR_033900 F11-AS1 Silent rs11945366 4 187331659 [A/G] NR_033900 F11-AS1 Silent rs6826848 4 187340605 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs11931790 4 187340688 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs2060767 4 187341533 [A/G] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs7669240 4 187347487 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 EXON Silent,Silent rs7691259 4 187347655 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 EXON Silent,Silent rs4862695 4 187358040 [A/G] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs10454254 4 187360776 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs6844494 4 187361302 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs10434307 4 187361370 [A/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs969372 4 187365460 [A/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs1812785 4 187365581 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs2084729 4 187365864 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs11132396 4 187365960 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs9999651 4 187366649 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs1037354 4 187367404 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs7654929 4 187367442 [A/G] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs1868894 4 187369734 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs11723365 4 187371043 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs2375775 4 187372264 [A/G] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs4241830 4 187375370 [A/G] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs1839746 4 187376559 [T/G] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs7670038 4 187378007 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs10004538 4 187378920 [A/G] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs12506228 4 187382294 [A/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs6846710 4 187382542 [A/G] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs11723770 4 187387204 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs10003777 4 187388958 [A/G] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs1901317 4 187390680 [A/G] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs1376535 4 187390722 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs1376534 4 187390861 [A/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs6832915 4 187391215 [A/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs6830267 4 187403169 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs10866292 4 187404608 [T/G] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs11723176 4 187411297 [A/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs6854525 4 187411620 [A/G] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs921453 4 187411802 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs2375799 4 187414115 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs11729609 4 187421810 [T/C] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs6553000 4 187421850 [A/G] NR_033900,NR_033901 F11-AS1,F11-AS1 Silent,Silent rs10022244 4 187424564 [T/C] rs11736645 4 187427709 [A/G] rs11734081 4 187431073 [A/G] rs7699670 4 187437315 [A/G] rs10049809 4 187444718 [T/C] rs4862705 4 187445552 [A/G] rs7440284 4 187449434 [T/C] rs6553008 4 187455946 [T/C] NM_005958 MTNR1A Silent rs6553010 4 187456343 [A/G] NM_005958 MTNR1A Silent rs11943499 4 187460652 [T/C] NM_005958 MTNR1A Silent rs2165666 4 187461706 [A/G] NM_005958 MTNR1A Silent rs13140444 4 187465729 [T/C] NM_005958 MTNR1A Silent rs13113549 4 187465991 [A/G] NM_005958 MTNR1A Silent rs2119883 4 187469075 [T/C] NM_005958 MTNR1A Silent rs7687823 4 187482867 [A/G] rs13131052 4 187485933 [T/G] rs4862713 4 187487805 [A/G] rs6850080 4 187490395 [T/C] rs1867070 4 187491445 [T/C] rs11930659 4 187492881 [A/G] rs10001487 4 187508057 [A/G] rs3822059 4 187509217 [T/C] NM_005245 FAT1 EXON Silent rs7675885 4 187509321 [A/C] NM_005245 FAT1 EXON Silent rs7680937 4 187509492 [T/C] NM_005245 FAT1 EXON Silent rs3775307 4 187510280 [A/G] NM_005245 FAT1 EXON Synonymous_P4411P rs3775309 4 187513585 [T/G] NM_005245 FAT1 Silent rs1280092 4 187515047 [T/C] NM_005245 FAT1 Silent rs1298865 4 187516880 [A/G] NM_005245 FAT1 EXON Synonymous_S4367S rs2306989 4 187518871 [A/G] NM_005245 FAT1 EXON Synonymous_A4111A rs2306990 4 187518976 [T/C] NM_005245 FAT1 Silent rs10009030 4 187521037 [A/C] NM_005245 FAT1 Silent rs2637777 4 187525020 [A/C] NM_005245 FAT1 EXON Missense_S3554A rs1280103 4 187526002 [A/C] NM_005245 FAT1 Silent rs2584344 4 187527472 [A/G] NM_005245 FAT1 Silent rs2584345 4 187527818 [T/C] NM_005245 FAT1 Silent rs28647489 4 187531022 [A/G] NM_005245 FAT1 EXON Missense_V3334A rs2249916 4 187534363 [A/G] NM_005245 FAT1 EXON Synonymous_N3121N rs2249917 4 187534375 [A/G] NM_005245 FAT1 EXON Synonymous_D3117D rs1280099 4 187538330 [A/G] NM_005245 FAT1 EXON Synonymous_A2968A rs3733405 4 187539217 [A/G] NM_005245 FAT1 EXON Synonymous_N2841N rs726575 4 187539323 [T/C] NM_005245 FAT1 EXON Missense_S2806N rs3733406 4 187539588 [T/C] NM_005245 FAT1 EXON Missense_I2718V rs11931107 4 187540996 [T/C] NM_005245 FAT1 EXON Synonymous_P2248P rs3733407 4 187541761 [A/G] NM_005245 FAT1 EXON Synonymous_T1993T rs2099854 4 187542316 [T/C] NM_005245 FAT1 EXON Synonymous_V1808V rs6836935 4 187542927 [T/C] NM_005245 FAT1 EXON Missense_N1605D rs2304867 4 187549428 [T/C] NM_005245 FAT1 EXON Missense_A1564T rs10008621 4 187550697 [T/C] NM_005245 FAT1 Silent rs328420 4 187555387 [A/C] NM_005245 FAT1 Silent rs189031 4 187556139 [A/G] NM_005245 FAT1 Silent rs328418 4 187557893 [T/C] NM_005245 FAT1 EXON Missense_H1273R rs7663350 4 187561798 [T/C] NM_005245 FAT1 Silent rs328431 4 187573918 [T/C] NM_005245 FAT1 Silent rs1388297 4 187574398 [T/C] NM_005245 FAT1 Silent rs7672047 4 187580706 [T/C] NM_005245 FAT1 Silent rs12646129 4 187582660 [T/C] NM_005245 FAT1 Silent rs167853 4 187585952 [T/C] NM_005245 FAT1 Silent rs2130910 4 187586210 [T/C] NM_005245 FAT1 Silent rs10155467 4 187587980 [T/C] NM_005245 FAT1 Silent rs2130909 4 187588477 [A/G] NM_005245 FAT1 Silent rs2375889 4 187588695 [T/C] NM_005245 FAT1 Silent rs162182 4 187589603 [T/C] NM_005245 FAT1 Silent rs10025804 4 187590946 [T/C] NM_005245 FAT1 Silent rs4862723 4 187591526 [T/C] NM_005245 FAT1 Silent rs327080 4 187593959 [T/C] NM_005245 FAT1 Silent rs455600 4 187601962 [T/C] NM_005245 FAT1 Silent rs10020743 4 187614434 [T/C] NM_005245 FAT1 Silent rs6818461 4 187621281 [A/G] NM_005245 FAT1 Silent rs907986 4 187621568 [A/C] NM_005245 FAT1 Silent rs455219 4 187622064 [A/G] NM_005245 FAT1 Silent rs13123522 4 187627160 [T/C] NM_005245 FAT1 Silent rs11939575 4 187627792 [T/C] NM_005245 FAT1 EXON Missense_R1064G rs367863 4 187629140 [C/G] NM_005245 FAT1 EXON Missense_F614L rs3733413 4 187629538 [T/C] NM_005245 FAT1 EXON Missense_V482I rs3733414 4 187629770 [A/C] NM_005245 FAT1 EXON Missense_S404R rs3733415 4 187630590 [A/G] NM_005245 FAT1 EXON Missense_A131V rs327095 4 187638636 [A/C] NM_005245 FAT1 Silent rs327102 4 187640836 [T/C] NM_005245 FAT1 Silent rs7673895 4 187652655 [T/G] rs11132407 4 187656456 [T/G] rs7698262 4 187661911 [T/C] rs6553019 4 187668795 [A/G] rs6553020 4 187668886 [T/C] rs925642 4 187678866 [T/C] rs3733416 4 187680241 [A/G] rs7660386 4 187688114 [A/G] rs6856002 4 187693326 [T/C] rs9995398 4 187695564 [T/C] rs161711 4 187696656 [A/G] rs6833702 4 187696768 [T/C] rs6834299 4 187697015 [T/C] rs13145229 4 187701648 [T/C] rs6847347 4 187707798 [T/C] rs766685 4 187712375 [A/G] rs11733039 4 187714691 [A/C] rs11132408 4 187716010 [T/G] rs12640954 4 187718537 [A/G] rs11132409 4 187722479 [T/C] rs7657648 4 187724314 [T/G] rs1019895 4 187729614 [T/C] rs7689213 4 187730631 [A/G] rs9992417 4 187745843 [T/C] rs10028835 4 187747224 [T/C] rs1583219 4 187751154 [T/C] rs13105379 4 187754871 [A/G] rs4862735 4 187756317 [T/G] rs10000282 4 187759002 [T/C] rs10033282 4 187759082 [A/G] rs11132410 4 187774488 [T/C] rs1431929 4 187775324 [A/G] rs443846 4 187779084 [T/C] rs322442 4 187788311 [A/G] rs322447 4 187792665 [T/G] rs172818 4 187797022 [A/C] rs322453 4 187799603 [A/G] rs4862740 4 187802501 [A/G] rs170427 4 187804194 [A/G] rs736879 4 187813409 [T/C] rs736880 4 187813575 [A/C] rs397321 4 187815647 [A/G] rs4862742 4 187817303 [A/G] rs10030988 4 187818100 [T/C] rs9685837 4 187818466 [A/G] rs578135 4 187821208 [T/C] rs9991793 4 187825117 [A/G] rs322398 4 187828093 [T/C] rs1895844 4 187833759 [T/C] rs322429 4 187836373 [T/C] rs10018164 4 187843726 [A/G] rs10033110 4 187845057 [T/C] rs6815445 4 187845789 [A/G] rs6829485 4 187848075 [A/G] rs7682123 4 187851288 [T/C] rs7657521 4 187851352 [T/C] rs999319 4 187854369 [T/G] rs728664 4 187855418 [T/C] rs1158815 4 187857192 [A/G] rs754548 4 187860363 [A/G] rs13137204 4 187864673 [A/G] rs13143485 4 187870988 [A/G] rs9312351 4 187871454 [T/C] rs9998558 4 187874691 [A/G] rs7658351 4 187875680 [T/G] rs7696677 4 187880098 [T/C] rs13152414 4 187894710 [A/G] rs6836076 4 187899660 [A/C] rs6858853 4 187903412 [T/G] rs6835681 4 187903476 [T/C] rs13131381 4 187912810 [T/C] rs10471185 4 187915635 [A/G] rs966575 4 187916373 [T/C] rs966576 4 187916415 [A/G] rs10026367 4 187916497 [T/C] rs11935239 4 187916576 [A/C] rs6829136 4 187926758 [T/G] rs6851529 4 187932470 [T/C] rs6856787 4 187932716 [T/C] rs7687629 4 187946831 [T/C] rs1559779 4 187949161 [T/C] rs715070 4 187954207 [A/G] rs7665944 4 187965051 [A/G] rs6835306 4 187966612 [T/C] rs13126183 4 187969016 [A/G] rs6814129 4 187969329 [A/G] rs6814850 4 187969452 [A/G] rs4476657 4 187978589 [A/G] rs4333244 4 187979306 [T/C] rs7441526 4 187979630 [A/G] rs4507419 4 187979712 [T/C] rs3923586 4 187980711 [T/C] rs4862758 4 187981262 [T/C] rs13141650 4 187999052 [T/C] rs4861739 4 188000355 [A/G] rs13104006 4 188000653 [T/G] rs7662795 4 188004538 [A/C] rs2029257 4 188005948 [T/G] rs1038598 4 188007418 [A/C] rs6818214 4 188009643 [A/G] rs7665787 4 188013721 [T/C] rs6553034 4 188013766 [A/G] rs1487599 4 188015375 [T/C] rs6836337 4 188015715 [T/C] rs6553036 4 188019647 [T/C] rs2129654 4 188021294 [A/G] rs11132424 4 188021812 [T/C] rs7659108 4 188021950 [A/G] rs13129961 4 188022194 [A/G] rs7692060 4 188026750 [T/G] rs11933149 4 188027586 [A/G] rs1487590 4 188030901 [A/G] rs6831979 4 188032844 [T/C] rs2376075 4 188040526 [T/C] rs4862774 4 188041074 [A/C] rs2029259 4 188047143 [A/C] rs10018611 4 188050164 [T/C] rs6858203 4 188051175 [A/G] rs10024641 4 188051690 [A/G] rs6826891 4 188056826 [T/C] rs4611977 4 188061467 [T/C] rs13145604 4 188071834 [T/G] rs1487582 4 188073672 [A/G] rs10016164 4 188073853 [A/G] rs882227 4 188077812 [A/G] rs11730573 4 188079254 [A/G] rs11132427 4 188079777 [A/G] rs10021692 4 188080985 [A/G] rs6815262 4 188081872 [A/C] rs4862782 4 188092843 [T/C] rs10003140 4 188095514 [T/C] rs6826520 4 188099394 [T/C] rs1027058 4 188100049 [T/C] rs3860698 4 188100664 [A/G] rs10000307 4 188103937 [T/C] rs931370 4 188105792 [A/C] rs13145216 4 188106544 [A/G] rs10012982 4 188107815 [T/C] rs1979570 4 188108024 [A/G] rs1038599 4 188110164 [A/C] rs4472191 4 188114093 [T/C] rs7692743 4 188114879 [A/G] rs13121701 4 188115905 [A/G] rs1021287 4 188116718 [A/G] rs7684803 4 188117428 [T/C] rs6811993 4 188125082 [T/C] NR_147159 LINC02374 Silent rs7674650 4 188127832 [T/C] NR_147159 LINC02374 Silent rs6845980 4 188131680 [A/G] NR_147159 LINC02374 Silent rs1565106 4 188136307 [A/G] rs7699015 4 188138856 [T/C] rs1532024 4 188148405 [A/G] rs7695955 4 188157742 [T/C] rs1532021 4 188159641 [T/C] rs6816228 4 188160927 [T/C] rs6831858 4 188166889 [A/G] rs4321687 4 188172182 [A/G] rs6553050 4 188185489 [T/C] rs13131356 4 188186007 [T/C] rs10461324 4 188186955 [A/C] rs7695747 4 188191315 [A/G] rs4478240 4 188191516 [T/C] rs4862792 4 188201350 [T/G] rs13126689 4 188209801 [T/C] rs4308418 4 188213866 [T/C] rs6553055 4 188219193 [A/C] rs9993067 4 188223037 [T/C] rs2045725 4 188223165 [T/G] rs976000 4 188227951 [T/C] NR_038931 LOC339975 Silent rs6836534 4 188230701 [T/C] NR_038931 LOC339975 EXON Silent rs10031096 4 188250769 [T/C] NR_038931 LOC339975 Silent rs1319774 4 188258978 [T/C] NR_038931 LOC339975 Silent rs1156741 4 188265382 [A/G] NR_038931 LOC339975 Silent rs7679761 4 188268391 [T/C] NR_038931 LOC339975 Silent rs1870852 4 188280616 [T/C] NR_038931 LOC339975 Silent rs2376165 4 188284813 [A/G] NR_038931 LOC339975 Silent rs13107031 4 188289740 [A/C] NR_038931 LOC339975 Silent rs11132443 4 188292015 [A/C] NR_038931,NR_149103 LOC339975,LINC02514 Silent,Silent rs3911752 4 188294980 [A/G] NR_038931 LOC339975 Silent rs12505423 4 188295836 [A/G] NR_038931 LOC339975 Silent rs7692616 4 188297923 [T/C] NR_038931 LOC339975 Silent rs7684641 4 188302273 [A/G] NR_038931 LOC339975 Silent rs10018680 4 188311821 [T/C] NR_038931 LOC339975 Silent rs4862801 4 188317381 [T/G] NR_038931 LOC339975 Silent rs4862802 4 188317437 [A/G] NR_038931 LOC339975 Silent rs2217486 4 188332196 [T/C] NR_038931 LOC339975 Silent rs11132449 4 188345346 [T/G] NR_038931 LOC339975 Silent rs1431005 4 188345368 [A/G] NR_038931 LOC339975 Silent rs11724481 4 188351787 [A/C] NR_038931 LOC339975 Silent rs11132451 4 188364027 [T/C] NR_038931 LOC339975 Silent rs12641785 4 188364088 [A/G] NR_038931 LOC339975 Silent rs1864603 4 188365395 [T/G] NR_038931 LOC339975 Silent rs12508101 4 188369068 [A/C] NR_038931 LOC339975 Silent rs12651353 4 188376505 [T/G] NR_038931 LOC339975 Silent rs6553069 4 188381449 [A/G] NR_038931 LOC339975 Silent rs10034118 4 188386016 [T/C] NR_038931 LOC339975 Silent rs7691606 4 188391246 [T/C] NR_038931 LOC339975 Silent rs13141517 4 188394768 [A/G] NR_038931 LOC339975 Silent rs4862809 4 188398663 [T/C] NR_038931 LOC339975 Silent rs4862810 4 188398695 [T/C] NR_038931 LOC339975 Silent rs13133599 4 188399309 [A/G] NR_038931 LOC339975 Silent rs13133236 4 188399321 [T/C] NR_038931 LOC339975 Silent rs7667497 4 188406503 [A/G] NR_038931 LOC339975 Silent rs10027738 4 188411479 [A/G] NR_038931 LOC339975 Silent rs10021479 4 188416501 [A/G] NR_038931 LOC339975 Silent rs1367555 4 188420909 [A/G] NR_038931 LOC339975 Silent rs10001779 4 188423355 [A/G] NR_038931 LOC339975 Silent rs4861749 4 188426129 [T/C] NR_038931 LOC339975 Silent rs10026177 4 188428740 [A/G] rs10032833 4 188431411 [T/C] rs11929993 4 188432233 [T/C] rs28475332 4 188434677 [A/G] rs13122177 4 188439795 [A/G] rs10032493 4 188461119 [A/C] NR_110436 LINC02492 Silent rs6857356 4 188469538 [A/G] NR_110436 LINC02492 Silent rs4862815 4 188479049 [T/G] NR_110436 LINC02492 Silent rs1532857 4 188479688 [T/C] NR_110436 LINC02492 Silent rs1553566 4 188480913 [T/C] NR_110436 LINC02492 Silent rs7677258 4 188486138 [T/C] NR_110436 LINC02492 Silent rs6812381 4 188493082 [A/G] NR_110436 LINC02492 Silent rs11734029 4 188498590 [T/C] NR_110436 LINC02492 Silent rs871603 4 188499628 [T/C] NR_110436 LINC02492 Silent rs6826401 4 188509004 [T/C] NR_110436 LINC02492 Silent rs1505505 4 188522356 [A/G] NR_110436 LINC02492 Silent rs1553562 4 188524389 [A/G] NR_110436 LINC02492 Silent rs13147499 4 188526344 [A/G] NR_110436 LINC02492 Silent rs13150936 4 188531799 [A/C] NR_110436 LINC02492 Silent rs1876072 4 188536462 [A/G] NR_110436 LINC02492 Silent rs1354634 4 188547880 [T/C] NR_110436 LINC02492 Silent rs11943288 4 188548117 [T/C] NR_110436 LINC02492 Silent rs2279883 4 188554682 [T/C] NR_110436 LINC02492 Silent rs1505509 4 188570203 [A/G] NR_110436 LINC02492 Silent rs10028895 4 188575728 [T/C] NR_110436 LINC02492 Silent rs10866300 4 188576298 [T/C] NR_110436 LINC02492 Silent rs2292161 4 188581325 [A/G] NR_110436 LINC02492 Silent rs9992899 4 188583907 [T/C] NR_110436 LINC02492 Silent rs11929702 4 188586853 [A/C] NR_110436 LINC02492 Silent rs1466956 4 188590603 [A/G] NR_110436 LINC02492 Silent rs11930461 4 188590745 [A/C] NR_110436 LINC02492 Silent rs7684752 4 188597930 [T/C] rs6826851 4 188608123 [A/G] rs7687115 4 188608857 [A/G] rs9992966 4 188615607 [T/C] rs9993712 4 188616420 [T/C] rs10026452 4 188627935 [T/C] rs12648438 4 188628654 [A/C] rs4266338 4 188632948 [T/C] rs6844220 4 188645813 [A/G] rs10008174 4 188646845 [T/G] rs7438821 4 188650233 [T/G] rs11723292 4 188652223 [T/C] rs6553094 4 188658741 [A/G] rs13139954 4 188661045 [A/G] rs13151215 4 188665614 [T/C] rs13114385 4 188669480 [A/C] rs7658700 4 188675224 [T/C] rs9992060 4 188680866 [T/C] rs13148546 4 188690307 [A/C] rs7683009 4 188698095 [T/C] rs10006997 4 188701437 [T/G] rs4861758 4 188707091 [T/G] rs6849009 4 188716736 [T/C] rs4318702 4 188717853 [T/C] rs4470690 4 188721512 [A/C] rs4481281 4 188721544 [T/C] rs6845047 4 188724806 [T/C] rs10017989 4 188730709 [T/C] rs10028606 4 188731055 [A/C] rs9996150 4 188734615 [A/G] rs6829286 4 188735086 [T/C] rs6816835 4 188736913 [A/G] rs4862831 4 188744214 [A/G] rs13125278 4 188744789 [T/C] rs4566706 4 188746046 [A/G] rs13120072 4 188770791 [T/C] rs12648158 4 188786838 [T/C] rs4377642 4 188792218 [T/C] rs4862838 4 188801533 [A/G] rs12644677 4 188802381 [A/G] rs13139939 4 188804628 [T/C] rs4618368 4 188805951 [T/C] rs4315850 4 188815970 [T/G] rs12643580 4 188821578 [T/G] rs10866303 4 188829088 [A/G] rs11132490 4 188834175 [A/C] rs13121765 4 188836402 [T/G] rs4862840 4 188840051 [A/G] rs6813823 4 188842209 [A/G] rs6553113 4 188843305 [T/C] rs10866305 4 188844211 [A/G] rs7667835 4 188848924 [T/G] rs6821751 4 188851691 [T/C] rs10018412 4 188856373 [T/C] rs11936270 4 188856430 [A/C] rs2131290 4 188859908 [A/G] rs7696985 4 188865510 [T/C] rs12644789 4 188887420 [T/C] rs4861762 4 188892958 [T/G] rs6835160 4 188894402 [T/C] rs6553120 4 188898937 [A/G] rs13146799 4 188899298 [T/C] rs7439650 4 188904235 [A/G] rs1105763 4 188905061 [T/C] rs6553122 4 188909667 [T/C] rs6836268 4 188911842 [T/C] rs28628755 4 188915984 [T/C] rs4862848 4 188921440 [A/G] NM_174900,NM_001304358 ZFP42,ZFP42 Silent,Silent rs6815391 4 188924979 [T/C] NM_174900,NM_001304358 ZFP42,ZFP42 EXON Silent,Silent rs6553126 4 188932750 [T/C] rs6840208 4 188933651 [A/G] rs952727 4 188935105 [T/C] rs952726 4 188935183 [T/C] rs6553129 4 188935662 [A/G] rs11733349 4 188936629 [T/C] rs6553132 4 188939849 [T/C] rs2131288 4 188943843 [A/G] rs2131287 4 188943890 [A/C] rs6553136 4 188945315 [A/G] rs6553138 4 188953780 [T/G] rs6853977 4 188956686 [T/C] rs2889360 4 188957800 [T/G] rs11937365 4 188958509 [T/C] rs11729469 4 188959641 [T/C] rs2376393 4 188959863 [A/G] rs10004698 4 188961336 [A/G] rs7437246 4 188962325 [T/C] rs1586887 4 188963197 [A/G] rs4440286 4 188963851 [A/G] rs2068445 4 188965567 [A/G] rs6553144 4 188965971 [A/G] rs12501116 4 188971489 [A/G] rs6847145 4 188978587 [T/C] rs1540663 4 188981386 [A/G] rs11132507 4 188985493 [T/C] rs11132508 4 188985500 [T/C] rs9997579 4 188990434 [T/C] rs4611976 4 188990955 [T/G] rs12644540 4 188998692 [T/C] rs6853509 4 188999227 [T/C] rs4299646 4 189007284 [A/G] rs6849766 4 189010521 [A/G] rs12647135 4 189011174 [A/C] rs2279551 4 189012809 [T/C] NM_173553,NM_001303419 TRIML2,TRIML2 EXON Synonymous_S344S,Synonymous_S369S rs10004012 4 189018613 [A/G] NM_173553,NM_001303419 TRIML2,TRIML2 Silent,Silent rs902910 4 189020348 [A/G] NM_173553,NM_001303419 TRIML2,TRIML2 Silent,Silent rs4862860 4 189022420 [A/G] NM_173553,NM_001303419 TRIML2,TRIML2 Silent,Silent rs9684216 4 189031028 [A/G] rs10015609 4 189034513 [T/C] rs13116982 4 189036322 [A/G] rs6553155 4 189045617 [A/G] rs6419960 4 189055298 [A/G] rs7376389 4 189057415 [A/G] rs7441586 4 189059078 [T/C] rs34645730 4 189059174 [T/C] rs11938607 4 189060431 [T/C] rs13131525 4 189061106 [A/G] NM_178556 TRIML1 EXON Missense_E132K rs6553160 4 189062214 [T/C] NM_178556 TRIML1 Silent rs11940071 4 189064988 [T/G] NM_178556 TRIML1 Silent rs7694050 4 189065934 [A/G] NM_178556 TRIML1 Silent rs11733655 4 189069181 [T/C] rs11723187 4 189070726 [A/G] rs11132521 4 189081654 [A/G] rs4349672 4 189088220 [T/C] rs4863142 4 189092589 [A/G] rs4863164 4 189092903 [A/G] rs12501503 4 189095240 [A/C] rs4323178 4 189095790 [T/G] rs6827299 4 189098744 [T/C] rs7375996 4 189101482 [A/G] rs7665403 4 189101773 [T/C] rs4492063 4 189115231 [A/G] rs6818741 4 189119202 [T/C] rs6857559 4 189120911 [T/C] rs4863348 4 189120984 [A/G] rs7376568 4 189133207 [T/G] rs6813871 4 189134108 [T/C] rs4863386 4 189138814 [A/C] rs7677236 4 189139258 [A/G] rs7682583 4 189139613 [A/G] rs10001461 4 189143475 [A/G] rs3924963 4 189144799 [T/C] rs4863391 4 189148200 [T/C] rs12650036 4 189150117 [A/G] rs6553184 4 189150656 [A/G] rs4279287 4 189151984 [A/G] rs4863421 4 189158163 [A/G] rs4863079 4 189166087 [T/C] rs4476671 4 189171046 [T/C] rs4551004 4 189175651 [A/G] rs13145617 4 189181266 [A/G] rs12374353 4 189188139 [T/C] rs7375584 4 189189170 [A/G] rs4863124 4 189189273 [T/C] rs7378399 4 189194661 [A/G] rs4077675 4 189196692 [T/G] rs11132538 4 189205404 [T/C] rs7654820 4 189213140 [A/G] rs7661001 4 189213925 [A/C] rs10006245 4 189214720 [A/G] rs4618385 4 189216438 [T/G] rs7666115 4 189218156 [T/C] rs11735401 4 189220431 [A/G] rs6830572 4 189221207 [A/G] rs10017800 4 189223524 [A/G] rs4862987 4 189227731 [A/G] rs6553193 4 189229216 [A/G] rs7696358 4 189229584 [A/G] rs11724270 4 189230337 [T/C] rs6828177 4 189233294 [A/G] rs7671200 4 189233358 [T/G] rs12647565 4 189236548 [T/C] rs12639689 4 189240218 [A/G] rs12501166 4 189246406 [T/G] rs11935681 4 189247480 [T/C] rs11930915 4 189247773 [A/G] rs11931980 4 189254197 [A/G] rs7375343 4 189260808 [A/G] rs4863305 4 189262246 [A/C] rs6841379 4 189265168 [A/G] rs6553197 4 189266054 [T/C] rs952719 4 189271272 [T/G] rs12501958 4 189282465 [T/G] rs11132547 4 189285725 [A/C] rs11728000 4 189288209 [T/C] rs1507074 4 189288591 [T/C] rs4863321 4 189293076 [A/G] rs6553200 4 189295229 [T/C] rs314077 4 189296002 [T/C] rs1606234 4 189296032 [A/G] rs314078 4 189296076 [A/C] rs11726434 4 189296513 [A/G] rs11938549 4 189300955 [T/C] rs2055918 4 189300970 [A/C] rs6553201 4 189303096 [T/C] rs7669530 4 189303437 [A/G] rs12505859 4 189305026 [A/G] rs12499318 4 189306182 [A/G] rs314054 4 189306960 [A/G] rs12510602 4 189310768 [T/C] rs2019991 4 189313568 [T/C] rs2376746 4 189313688 [T/G] rs13104957 4 189314208 [T/G] rs10028269 4 189315208 [T/G] rs314102 4 189321030 [A/G] rs314104 4 189326076 [T/C] rs12648353 4 189331063 [A/G] rs10009683 4 189333660 [A/G] rs12512320 4 189333901 [A/G] rs12504808 4 189334307 [T/C] rs314034 4 189334992 [A/G] rs2292432 4 189338040 [A/G] rs2292433 4 189338469 [T/C] rs10008710 4 189338814 [T/C] rs4362867 4 189339341 [A/G] rs713508 4 189341977 [T/G] rs4395553 4 189342143 [T/C] rs713507 4 189342369 [A/G] rs1857955 4 189342799 [T/C] rs11132551 4 189343008 [T/C] rs13434896 4 189344762 [A/C] rs7690014 4 189344863 [T/C] rs993424 4 189347578 [T/C] rs869570 4 189351268 [T/C] rs12505646 4 189355668 [T/C] rs10026052 4 189362292 [A/G] rs13107630 4 189365509 [T/C] rs2292434 4 189371244 [A/G] rs436141 4 189376479 [T/C] rs425974 4 189377718 [A/C] NR_033869 LINC01060 Silent rs372298 4 189379520 [T/C] NR_033869 LINC01060 Silent rs10019893 4 189384671 [A/C] NR_033869 LINC01060 Silent rs314065 4 189388320 [T/G] NR_033869 LINC01060 Silent rs13114765 4 189390949 [T/G] NR_033869 LINC01060 Silent rs9996809 4 189394485 [A/G] NR_033869 LINC01060 Silent rs11734013 4 189402063 [A/G] NR_033869 LINC01060 Silent rs2089408 4 189402769 [A/G] NR_033869 LINC01060 Silent rs1911504 4 189404004 [A/G] NR_033869 LINC01060 Silent rs11132554 4 189404814 [T/C] NR_033869 LINC01060 Silent rs6855687 4 189412980 [A/G] NR_033869 LINC01060 Silent rs12648691 4 189414006 [A/G] NR_033869 LINC01060 Silent rs12510507 4 189414658 [T/C] NR_033869 LINC01060 Silent rs6833998 4 189416683 [A/G] NR_033869 LINC01060 Silent rs1976536 4 189417612 [T/C] NR_033869 LINC01060 Silent rs6812291 4 189419282 [A/G] NR_033869 LINC01060 Silent rs4863330 4 189430792 [A/G] NR_033869 LINC01060 Silent rs1395612 4 189433290 [A/G] NR_033869 LINC01060 Silent rs931887 4 189433525 [A/G] NR_033869 LINC01060 Silent rs931885 4 189433594 [T/C] NR_033869 LINC01060 Silent rs10011727 4 189434690 [T/C] NR_033869 LINC01060 Silent rs10018170 4 189436829 [T/C] NR_033869 LINC01060 Silent rs11132556 4 189436841 [T/C] NR_033869 LINC01060 Silent rs7671323 4 189437449 [T/C] NR_033869 LINC01060 Silent rs4863333 4 189439821 [T/G] NR_033869 LINC01060 Silent rs7677233 4 189439872 [A/G] NR_033869 LINC01060 Silent rs10033480 4 189447377 [A/G] NR_033869 LINC01060 Silent rs6553202 4 189449669 [A/G] NR_033869 LINC01060 Silent rs7654439 4 189455974 [A/C] NR_033869 LINC01060 Silent rs7679676 4 189456233 [T/G] NR_033869 LINC01060 Silent rs1511805 4 189457782 [T/C] NR_033869 LINC01060 Silent rs4863340 4 189463597 [A/C] NR_033869 LINC01060 Silent rs10866310 4 189466381 [T/C] NR_033869 LINC01060 Silent rs10023035 4 189470223 [T/G] NR_033869 LINC01060 Silent rs13130582 4 189470492 [T/C] NR_033869 LINC01060 Silent rs9994095 4 189475324 [T/C] NR_033869 LINC01060 Silent rs6826087 4 189475684 [A/G] NR_033869 LINC01060 Silent rs2376964 4 189478215 [A/G] NR_033869 LINC01060 Silent rs7667826 4 189488132 [T/C] NR_033869 LINC01060 Silent rs7700176 4 189489351 [A/G] NR_033869 LINC01060 Silent rs6830571 4 189492177 [T/C] NR_033869 LINC01060 Silent rs12645101 4 189495641 [T/C] NR_033869 LINC01060 Silent rs7666129 4 189498064 [T/C] NR_033869 LINC01060 Silent rs12643289 4 189499145 [T/C] NR_033869 LINC01060 Silent rs12640778 4 189499621 [T/C] NR_033869 LINC01060 Silent rs12640838 4 189499865 [A/C] NR_033869 LINC01060 Silent rs11132562 4 189500458 [A/G] NR_033869 LINC01060 Silent rs4863049 4 189501949 [A/G] NR_033869 LINC01060 Silent rs7663546 4 189502823 [A/C] NR_033869 LINC01060 Silent rs11735644 4 189507018 [T/C] NR_033869 LINC01060 Silent rs4863054 4 189508238 [A/G] NR_033869 LINC01060 Silent rs4863057 4 189508492 [A/G] NR_033869 LINC01060 Silent rs12512555 4 189510469 [A/C] NR_033869 LINC01060 Silent rs13128985 4 189519649 [A/G] NR_033869 LINC01060 Silent rs4863354 4 189522110 [T/C] NR_033869 LINC01060 Silent rs4549442 4 189522393 [A/G] NR_033869 LINC01060 Silent rs2377343 4 189524738 [T/C] rs12501064 4 189525837 [A/G] rs4241895 4 189528831 [T/C] rs11735471 4 189536624 [T/C] rs2010907 4 189540683 [A/G] rs6817256 4 189541364 [T/C] rs1382425 4 189541446 [A/C] rs11735347 4 189542277 [T/G] rs12510167 4 189544738 [A/C] rs456469 4 189544807 [A/G] rs10866311 4 189545795 [T/C] rs458862 4 189545959 [T/C] rs11729434 4 189547648 [A/G] rs690149 4 189548540 [T/C] rs690143 4 189548599 [T/G] rs464270 4 189554217 [T/C] rs10024926 4 189557313 [A/G] rs13110503 4 189557490 [T/C] rs4403095 4 189558299 [T/C] rs734521 4 189558312 [A/C] rs11132565 4 189563127 [T/C] rs6834498 4 189565170 [T/C] rs360117 4 189571541 [T/C] rs6553217 4 189578979 [T/C] rs1879985 4 189580139 [T/C] rs7686384 4 189584353 [T/C] rs899273 4 189584904 [T/C] rs7659062 4 189587079 [T/C] rs7659814 4 189587367 [A/G] rs1478563 4 189589490 [T/C] rs7662358 4 189590859 [A/C] rs4863376 4 189592930 [A/G] rs4863380 4 189600713 [T/C] rs1038095 4 189608461 [A/G] rs10434313 4 189616701 [A/G] rs6815218 4 189628999 [T/C] rs6818117 4 189633448 [T/G] rs6837842 4 189636244 [T/C] rs13106691 4 189636722 [T/C] rs1461776 4 189639545 [A/G] rs13111649 4 189642697 [A/C] rs6832545 4 189643752 [T/C] rs7681177 4 189653624 [A/G] rs930995 4 189654390 [T/C] rs6553229 4 189660025 [C/G] rs6553230 4 189660276 [A/G] rs7685306 4 189663354 [T/C] rs11132580 4 189665842 [A/C] rs1350865 4 189668536 [A/G] rs13133211 4 189672283 [T/C] rs2377333 4 189673054 [A/G] rs6849122 4 189673094 [T/C] rs2377334 4 189673284 [A/G] rs6827397 4 189676850 [T/C] rs4254824 4 189680142 [A/G] rs12502652 4 189680843 [A/G] rs13146779 4 189683163 [T/C] rs4863387 4 189687397 [T/C] rs1350864 4 189688859 [A/C] rs13143885 4 189689395 [T/C] rs10000370 4 189690332 [A/G] rs10000272 4 189690383 [T/C] rs11724214 4 189701600 [A/G] NR_149102 LINC02508 Silent rs1461780 4 189713163 [T/C] rs7660712 4 189728235 [T/G] rs3911069 4 189737788 [A/C] rs1073671 4 189742516 [T/C] rs9999605 4 189749745 [A/G] rs2377459 4 189756948 [A/G] rs2377462 4 189757132 [T/C] rs13150491 4 189759434 [T/C] rs4359959 4 189759591 [T/C] rs6553238 4 189759697 [T/C] rs4460045 4 189759885 [A/G] rs1947186 4 189762669 [A/G] rs6840969 4 189763385 [T/C] rs6834584 4 189765784 [T/C] rs7661693 4 189766744 [T/G] rs1448738 4 189785918 [A/G] rs6815501 4 189791103 [T/C] rs4526017 4 189792929 [A/G] rs6828833 4 189792991 [T/C] rs10434316 4 189797616 [A/C] rs10434317 4 189797770 [A/G] rs10434319 4 189798780 [A/G] rs2218692 4 189800486 [T/G] rs2376962 4 189805789 [A/G] rs2122061 4 189806380 [T/C] rs12498968 4 189812524 [T/C] rs6553246 4 189813964 [T/C] rs1597230 4 189814241 [A/C] rs10471186 4 189817730 [T/C] rs7669213 4 189818663 [T/C] rs13120352 4 189819886 [A/C] rs1448742 4 189824882 [A/G] rs11733637 4 189827490 [A/G] rs7682983 4 189828192 [T/G] rs1448726 4 189831920 [A/G] rs11737696 4 189832743 [T/G] rs6838391 4 189842118 [A/G] rs13107204 4 189842681 [T/C] rs7677253 4 189844501 [T/C] rs9312388 4 189847976 [A/G] rs10001577 4 189850773 [T/C] rs3860664 4 189851017 [A/G] rs4863076 4 189861178 [T/G] rs6853039 4 189861553 [T/C] rs12647666 4 189862164 [T/G] rs3860668 4 189868753 [T/G] rs11937288 4 189870956 [A/C] rs10027878 4 189876706 [A/G] rs7658965 4 189881357 [A/G] rs3860674 4 189882597 [T/C] rs6840831 4 189884512 [A/C] rs12507360 4 189885883 [T/C] rs3849635 4 189887863 [T/G] rs7662770 4 189891709 [A/G] rs6820632 4 189892200 [A/G] rs11941699 4 189896929 [A/G] rs10012177 4 189906617 [A/G] rs11132593 4 189910956 [A/G] rs10007514 4 189914135 [T/C] rs6827781 4 189917515 [T/G] rs4863432 4 189924789 [A/G] rs13117955 4 189926941 [T/G] rs10018868 4 189931630 [T/G] rs1908801 4 189939769 [A/G] rs11132597 4 189942126 [A/C] rs1390881 4 189949002 [A/G] rs11941513 4 189949645 [A/C] rs10020429 4 189950397 [A/G] rs7656029 4 189950840 [A/G] rs13126066 4 189951379 [A/G] rs10004274 4 189952149 [A/G] rs1463792 4 189957977 [T/G] rs6838005 4 189958110 [T/C] rs2029952 4 189962722 [A/C] rs4632707 4 189964583 [A/G] rs1390887 4 189965785 [A/G] rs1982946 4 189967275 [A/C] rs7688840 4 189969670 [T/C] rs6825584 4 189982824 [A/C] rs7676159 4 189984206 [A/C] rs4863449 4 189987905 [T/C] rs4863450 4 189988249 [T/C] rs4863452 4 189989962 [A/G] rs1353581 4 189989989 [A/G] rs10016346 4 189996454 [T/C] rs1948573 4 189998904 [T/C] rs1496937 4 190004805 [A/G] rs1353582 4 190006491 [A/G] rs1353583 4 190006628 [T/C] rs2889670 4 190008231 [A/G] rs11931092 4 190010270 [T/C] rs7700119 4 190020650 [A/G] rs6857536 4 190033466 [T/C] rs6841266 4 190034291 [T/C] rs6835666 4 190036900 [T/G] rs2889668 4 190037254 [T/G] rs2377560 4 190037266 [A/C] rs2132663 4 190037550 [T/C] rs9631786 4 190042584 [A/G] rs7690324 4 190044374 [T/G] rs7695418 4 190044666 [T/G] rs4285137 4 190050735 [A/G] rs9993186 4 190056070 [A/C] rs6845602 4 190056255 [A/G] rs6852474 4 190057227 [A/G] rs13135232 4 190064912 [T/G] rs6822346 4 190065197 [A/G] rs6834497 4 190066616 [T/C] rs4302526 4 190069486 [A/G] rs11944137 4 190069501 [T/C] rs4241915 4 190070914 [A/G] rs11737011 4 190071985 [A/G] rs4863105 4 190080067 [A/G] rs13106777 4 190085731 [A/G] rs9996363 4 190087087 [A/G] rs10019172 4 190087210 [T/G] rs7677465 4 190087776 [T/C] rs7699928 4 190088167 [T/C] rs6848521 4 190093246 [T/C] rs4241857 4 190098562 [T/C] rs9312393 4 190101262 [A/C] rs6855006 4 190103064 [A/G] rs12650063 4 190111329 [A/G] rs11132619 4 190117114 [A/G] rs12647051 4 190118066 [T/C] rs6822278 4 190122932 [A/G] rs7437007 4 190126642 [T/C] rs11732071 4 190129325 [T/C] rs4863119 4 190129958 [T/G] rs4388153 4 190130152 [T/G] rs4863120 4 190130349 [T/C] rs11932479 4 190132623 [A/G] rs6833202 4 190137076 [A/C] rs10866319 4 190146555 [T/C] rs11940741 4 190147729 [T/C] rs10446846 4 190148795 [A/C] rs6856264 4 190150616 [A/G] rs4339259 4 190151383 [A/C] rs4434303 4 190158729 [T/C] rs4249884 4 190170631 [T/C] rs3922497 4 190170679 [A/G] rs4400040 4 190176475 [T/C] rs6553297 4 190181541 [A/C] rs9998868 4 190188452 [A/G] rs11721813 4 190189043 [T/C] rs6553301 4 190204029 [A/G] rs7667607 4 190206038 [T/C] rs4241871 4 190209288 [A/G] rs10006955 4 190223523 [T/C] rs6842514 4 190243940 [A/G] rs11132639 4 190256110 [T/G] rs6841296 4 190256300 [A/G] rs4863138 4 190261652 [A/G] rs4608851 4 190262811 [T/C] rs6828995 4 190262923 [T/C] rs13129984 4 190264846 [T/C] rs10032784 4 190268759 [T/C] rs10001776 4 190276865 [A/G] rs11930136 4 190278973 [A/G] rs9991497 4 190278985 [A/G] rs1037644 4 190290460 [A/G] rs11943937 4 190292844 [A/G] rs1563455 4 190293157 [T/G] rs870190 4 190294537 [T/C] rs4863145 4 190296345 [T/G] rs4863155 4 190300221 [A/G] rs876623 4 190306460 [A/C] rs1107680 4 190307284 [A/G] rs1563452 4 190311936 [T/G] rs11132649 4 190317498 [A/G] rs6553315 4 190328590 [T/C] rs1456340 4 190331143 [T/C] rs4863170 4 190333580 [T/C] rs1350180 4 190336803 [T/G] rs10034049 4 190338123 [T/G] rs872030 4 190341415 [T/C] rs9994370 4 190344851 [T/C] rs1869943 4 190346910 [T/G] rs11725224 4 190347036 [A/C] rs2054178 4 190347676 [A/G] rs6823300 4 190350300 [T/C] rs4148 4 190351843 [T/C] rs7680130 4 190355589 [A/G] rs1456354 4 190357461 [A/G] rs1125808 4 190360400 [T/C] rs6553316 4 190361647 [T/C] rs10007036 4 190371697 [A/G] rs867016 4 190374703 [A/G] rs12646102 4 190389490 [A/G] rs1840714 4 190394124 [T/C] rs12504268 4 190394821 [T/C] rs4862968 4 190407970 [T/G] rs9312400 4 190413642 [T/C] rs6838957 4 190414241 [A/G] rs11132664 4 190414910 [T/C] rs7686524 4 190427447 [A/G] rs1551137 4 190438606 [A/G] rs1597619 4 190448383 [T/C] rs9985694 4 190459134 [A/G] rs6826535 4 190467123 [A/G] rs11933070 4 190481771 [T/C] rs11724261 4 190522201 [A/G] rs4092077 4 190543118 [T/C] rs11729484 4 190552585 [T/C] rs11132733 4 190641170 [T/C] rs1915856 4 190685303 [A/G] rs2251432 4 190688592 [A/G] NR_149039 FRG1-DT Silent rs10011787 4 190690358 [A/C] NR_149039 FRG1-DT Silent rs7684487 4 190690945 [T/C] NR_149039 FRG1-DT Silent rs2256056 4 190703063 [T/G] NR_149039 FRG1-DT Silent rs1317423 4 190706132 [T/C] NR_149039 FRG1-DT Silent rs2140052 4 190708721 [T/C] NR_149039 FRG1-DT Silent rs2140051 4 190708873 [A/G] NR_149039 FRG1-DT Silent rs1996801 4 190710253 [T/C] NR_149039 FRG1-DT Silent rs11132766 4 190723160 [T/C] NR_149039 FRG1-DT Silent rs11732701 4 190723387 [A/G] NR_149039 FRG1-DT Silent rs2739553 4 190734306 [A/G] NR_149039 FRG1-DT Silent rs2293132 4 190742692 [T/C] NR_149039 FRG1-DT Silent rs6844114 4 190745892 [A/G] NR_149039 FRG1-DT Silent rs2685823 4 190748138 [A/G] NR_149039 FRG1-DT Silent rs2338111 4 190749996 [A/C] NR_149039 FRG1-DT Silent rs6553383 4 190753064 [T/C] NR_149039 FRG1-DT Silent rs2685875 4 190763337 [A/G] NR_149039 FRG1-DT Silent rs11931018 4 190763591 [A/G] NR_149039 FRG1-DT Silent rs6553385 4 190764527 [T/G] NR_149039 FRG1-DT Silent rs2739584 4 190777761 [T/C] NR_149039 FRG1-DT Silent rs13119686 4 190783028 [A/G] NR_149039 FRG1-DT Silent rs17080259 4 190838050 [T/C] NR_149039,NR_149038 FRG1-DT,FRG1-DT Silent,Silent rs1138726 4 190862083 [T/C] NM_004477 FRG1 EXON Silent rs4145513 4 190862103 [T/C] NM_004477 FRG1 EXON Silent rs4263440 4 190862126 [A/G] NM_004477 FRG1 EXON Silent rs12646565 4 190872778 [T/C] NM_004477 FRG1 Silent rs11736960 4 190880409 [A/G] NM_004477 FRG1 Silent rs2077107 4 190903688 [T/C] rs6838769 4 190915650 [A/G] rs2205338 4 190920523 [A/G] rs10015934 4 190922257 [T/C] rs2411553 4 190925357 [T/C] rs909274 4 190936728 [A/G] rs3903261 4 190963766 [T/C] rs10814410 9 46587 [T/C] rs7024750 9 78775 [A/G] NR_121190 PGM5P3-AS1 Silent rs2992854 9 185632 [A/C] rs3951559 9 188894 [A/G] rs3008128 9 191843 [A/G] rs10964134 9 204201 [A/G] rs478882 9 205964 [A/G] rs10757083 9 206132 [A/C] rs631411 9 209325 [T/C] rs584922 9 212761 [A/G] rs680654 9 213149 [A/G] NM_152569 C9orf66 EXON Silent rs2236547 9 214864 [T/C] NM_152569 C9orf66 EXON Missense_R178Q rs636922 9 215269 [A/C] NM_152569,NM_203447 C9orf66,DOCK8 EXON Missense_L43R,Silent rs4741635 9 217597 [A/G] NM_203447 DOCK8 Silent rs1536608 9 223613 [T/G] NM_203447 DOCK8 Silent rs541645 9 224227 [A/C] NM_203447 DOCK8 Silent rs12339394 9 227980 [A/G] NM_203447 DOCK8 Silent rs12338838 9 228848 [T/C] NM_203447 DOCK8 Silent rs10965205 9 229734 [T/G] NM_203447 DOCK8 Silent rs10965206 9 229826 [A/G] NM_203447 DOCK8 Silent rs496152 9 236828 [A/G] NM_203447 DOCK8 Silent rs10117655 9 238370 [A/G] NM_203447 DOCK8 Silent rs552848 9 238389 [A/G] NM_203447 DOCK8 Silent rs10965586 9 240571 [A/G] NM_203447 DOCK8 Silent rs661356 9 244457 [A/G] NM_203447 DOCK8 Silent rs7861294 9 248030 [T/G] NM_203447 DOCK8 Silent rs785838 9 248749 [T/C] NM_203447 DOCK8 Silent rs1336563 9 249281 [A/G] NM_203447 DOCK8 Silent rs13300102 9 250453 [A/G] NM_203447 DOCK8 Silent rs11792508 9 253594 [T/G] NM_203447 DOCK8 Silent rs492887 9 257973 [A/G] NM_203447 DOCK8 Silent rs573851 9 266505 [A/C] NM_203447 DOCK8 Silent rs526509 9 268740 [T/G] NM_203447 DOCK8 Silent rs554243 9 269510 [A/G] NM_203447 DOCK8 Silent rs589230 9 270422 [T/C] NM_203447 DOCK8 Silent rs10967209 9 271132 [A/G] NM_203447 DOCK8 Silent rs16926375 9 271228 [A/G] NM_203447 DOCK8 Silent rs682251 9 271455 [T/C] NM_203447 DOCK8 Silent rs10812374 9 272191 [T/C] NM_203447 DOCK8 Silent rs540909 9 273160 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10757606 9 274108 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs636918 9 274641 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs12347003 9 278018 [T/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs535474 9 279149 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10967642 9 279753 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs785850 9 281976 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10968012 9 286102 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs3209441 9 286491 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 EXON Missense_D63N,Silent,Silent rs529208 9 286593 [A/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 EXON Missense_P97T,Missense_P29T,Missense_P29T rs10968160 9 288611 [A/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs6476030 9 289061 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs7030730 9 290670 [A/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs17664531 9 290841 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs16929599 9 290844 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs943628 9 293360 [T/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs17664774 9 298719 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs785857 9 299315 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10757845 9 303639 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10757847 9 303727 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs13288618 9 304957 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10123577 9 305667 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs4741772 9 306906 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs4741775 9 307266 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs11789099 9 312134 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 EXON Missense_E237K,Missense_E169K,Missense_E169K rs12339042 9 312264 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs7024448 9 316515 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs12350941 9 317269 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs1980876 9 318153 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs4294238 9 318207 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs1556022 9 326767 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10970611 9 329462 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10970638 9 329830 [A/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10813766 9 331490 [T/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10970979 9 334337 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 EXON Missense_N413S,Missense_N345S,Missense_N345S rs12335694 9 334708 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs17722518 9 335387 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs7854418 9 335545 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs12377330 9 336026 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs4741814 9 336186 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs12347078 9 344508 [A/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs13292760 9 345900 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs1410216 9 347559 [A/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs13289414 9 348772 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs7855377 9 349518 [A/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs7855392 9 349557 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs11794685 9 349926 [A/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10971986 9 351793 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs943625 9 354334 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs1887528 9 354680 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs4741827 9 355718 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs4741828 9 355793 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10972190 9 356655 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs12551785 9 357653 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10972266 9 359338 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs4741833 9 362209 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs750587 9 362917 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs16935330 9 366216 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs11791465 9 366281 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10814269 9 366911 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10972564 9 367030 [T/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10972587 9 368030 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 EXON Synonymous_Y564Y,Synonymous_Y496Y,Synonymous_Y496Y rs17673268 9 368128 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 EXON Missense_A597V,Missense_A529V,Missense_A529V rs913703 9 370244 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 EXON Synonymous_K604K,Synonymous_K536K,Synonymous_K536K rs751352 9 370439 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs4436173 9 372341 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10973014 9 376538 [T/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs12348944 9 377066 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 EXON Synonymous_S765S,Synonymous_S697S,Synonymous_S697S rs954872 9 384134 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs954871 9 384150 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10814626 9 388167 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10491685 9 388900 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10814632 9 389285 [T/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs7028802 9 390228 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs2297075 9 390512 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 EXON Synonymous_T972T,Synonymous_T872T,Synonymous_T904T rs1571485 9 395025 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10739001 9 395250 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10973946 9 396232 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10973952 9 396293 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10814731 9 396380 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs7034926 9 396835 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 EXON Synonymous_F1007F,Synonymous_F907F,Synonymous_F939F rs16937932 9 396836 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 EXON Missense_R1008W,Missense_R908W,Missense_R940W rs12346176 9 398673 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs4741867 9 407227 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs12235927 9 413241 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10758556 9 419153 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10217719 9 422157 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs7853977 9 423052 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs6476809 9 423994 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs6476810 9 424327 [T/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10814854 9 424875 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10733505 9 425228 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs12353411 9 426215 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs12351212 9 427385 [T/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs2297082 9 428706 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs1329376 9 431860 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs7025078 9 432918 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10758582 9 433048 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs7040842 9 433347 [A/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs4740757 9 438295 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10974442 9 438779 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10758602 9 440683 [T/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs1887958 9 442030 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10974488 9 444116 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs4741955 9 447887 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs16908874 9 447960 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs4741958 9 448429 [A/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10974514 9 449373 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs2031946 9 449700 [T/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10491684 9 449798 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 EXON Synonymous_P1944P,Synonymous_P1844P,Synonymous_P1876P rs10814967 9 450420 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs16909299 9 452926 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs12682895 9 457305 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs7853027 9 459024 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10758625 9 460072 [T/C] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs10814999 9 460877 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 Silent,Silent,Silent rs3780338 9 464920 [A/G] NM_203447,NM_001190458,NM_001193536 DOCK8,DOCK8,DOCK8 EXON Silent,Silent,Silent rs4742002 9 466816 [A/G] rs10974637 9 468705 [T/C] rs1329381 9 469245 [T/G] rs10974644 9 469265 [T/G] rs13290574 9 469626 [A/G] rs10815034 9 469767 [A/C] rs913700 9 470086 [A/C] rs7867447 9 473379 [T/G] NM_001256876 KANK1 Silent rs7850568 9 474239 [A/G] NM_001256876 KANK1 Silent rs2282039 9 478153 [T/G] NM_001256876 KANK1 Silent rs2282038 9 478530 [A/G] NM_001256876 KANK1 Silent rs4742040 9 483018 [A/C] NM_001256876 KANK1 Silent rs2360717 9 483798 [T/C] NM_001256876 KANK1 Silent rs3739593 9 484336 [T/C] NM_001256876 KANK1 Silent rs4742043 9 484745 [A/G] NM_001256876 KANK1 Silent rs4742044 9 484786 [A/G] NM_001256876 KANK1 Silent rs10758653 9 489338 [A/G] NM_001256876 KANK1 Silent rs1007937 9 493247 [T/C] NM_001256876 KANK1 Silent rs7036591 9 500810 [A/G] NM_001256876 KANK1 Silent rs10118798 9 500979 [T/C] NM_001256876 KANK1 Silent rs10119358 9 503735 [T/C] NM_001256876 KANK1 Silent rs1410968 9 512589 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12343458 9 516413 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12343559 9 516638 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16917368 9 517563 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1928415 9 517715 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7026716 9 518675 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815156 9 518755 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2026075 9 520886 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16917912 9 521172 [A/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7853150 9 523495 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7856134 9 525814 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10974992 9 527180 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7024942 9 529916 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9408615 9 534065 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11789442 9 535866 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10120392 9 537358 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9299011 9 541031 [A/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742073 9 542531 [A/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16919380 9 544405 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9408628 9 544519 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7040388 9 544956 [A/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9299012 9 545680 [A/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10758683 9 546198 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16924533 9 548464 [A/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2279619 9 549518 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2804288 9 552324 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2641987 9 553248 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2641984 9 555653 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2641983 9 555772 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9632892 9 556399 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3739592 9 557617 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2804261 9 558343 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2804262 9 559714 [A/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2804264 9 564373 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16919733 9 564836 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2885157 9 569038 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs881985 9 569992 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2029726 9 571192 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7030028 9 571196 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10491600 9 582347 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9299021 9 582371 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7033716 9 585409 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2804280 9 589511 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11795359 9 589875 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2642006 9 590454 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16920619 9 590735 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10491598 9 592889 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17347399 9 594579 [A/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12346314 9 598223 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2642005 9 601493 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1532310 9 602986 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7850218 9 607738 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2804309 9 608622 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7046746 9 613571 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7028675 9 613908 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7041522 9 616783 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975462 9 623848 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10122300 9 625737 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16921323 9 626096 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12338965 9 628788 [A/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975480 9 629437 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6477056 9 634160 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7047127 9 635677 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16921551 9 641073 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16921577 9 641609 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16921797 9 649553 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9407334 9 651461 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975590 9 652957 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7851766 9 653505 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7021495 9 654101 [A/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742197 9 658446 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9408655 9 659722 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815440 9 661057 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742207 9 665516 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975653 9 666389 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975657 9 666970 [A/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11791986 9 674275 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742220 9 675419 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12685890 9 676704 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742226 9 678088 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12352279 9 678837 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1885925 9 679728 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1885924 9 679901 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975792 9 680323 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975803 9 680585 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7035584 9 680667 [A/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815466 9 680714 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9408671 9 680763 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17431629 9 680791 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1323263 9 680905 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9408674 9 681645 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9408678 9 686170 [A/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7034698 9 687205 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7044480 9 687265 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2361111 9 687592 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9299038 9 689340 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11999989 9 689740 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17432514 9 693182 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs732119 9 695607 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7854502 9 696683 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7029407 9 702412 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7019865 9 706479 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7848576 9 707463 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs912174 9 712156 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 EXON Missense_S464A,Missense_S306A,Missense_S464A,Missense_S464A,Missense_S464A,Missense_S464A,Missense_S464A,Missense_S306A,Missense_S306A,Missense_S306A,Missense_S306A,Missense_S306A,Missense_S306A,Missense_S306A,Silent,Missense_S306A,Missense_S306A,Missense_S306A,Missense_S306A rs11789987 9 712599 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 EXON Synonymous_N611N,Synonymous_N453N,Synonymous_N611N,Synonymous_N611N,Synonymous_N611N,Synonymous_N611N,Synonymous_N611N,Synonymous_N453N,Synonymous_N453N,Synonymous_N453N,Synonymous_N453N,Synonymous_N453N,Synonymous_N453N,Synonymous_N453N,Silent,Synonymous_N453N,Synonymous_N453N,Synonymous_N453N,Synonymous_N453N rs3824421 9 712757 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 EXON Missense_A664V,Missense_A506V,Missense_A664V,Missense_A664V,Missense_A664V,Missense_A664V,Missense_A664V,Missense_A506V,Missense_A506V,Missense_A506V,Missense_A506V,Missense_A506V,Missense_A506V,Missense_A506V,Silent,Missense_A506V,Missense_A506V,Missense_A506V,Missense_A506V rs3824420 9 712766 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 EXON Missense_R667H,Missense_R509H,Missense_R667H,Missense_R667H,Missense_R667H,Missense_R667H,Missense_R667H,Missense_R509H,Missense_R509H,Missense_R509H,Missense_R509H,Missense_R509H,Missense_R509H,Missense_R509H,Silent,Missense_R509H,Missense_R509H,Missense_R509H,Missense_R509H rs4740866 9 716570 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7043585 9 720179 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742292 9 720832 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815523 9 721717 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2885163 9 722946 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815530 9 724217 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10758839 9 724287 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12685329 9 725147 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12352313 9 730054 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 EXON Missense_N901S,Missense_N743S,Missense_N901S,Missense_N901S,Missense_N901S,Missense_N901S,Missense_N901S,Missense_N743S,Missense_N743S,Missense_N743S,Missense_N743S,Missense_N743S,Missense_N743S,Missense_N743S,Silent,Missense_N743S,Missense_N743S,Missense_N743S,Missense_N743S rs10815567 9 733049 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10429625 9 734679 [T/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2296052 9 738238 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2296051 9 738434 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 EXON Synonymous_N1161N,Synonymous_N1003N,Synonymous_N1161N,Synonymous_N1081N,Synonymous_N1143N,Synonymous_N1161N,Synonymous_N1161N,Synonymous_N1003N,Synonymous_N905N,Synonymous_N923N,Synonymous_N1003N,Synonymous_N985N,Synonymous_N985N,Synonymous_N985N,Silent,Synonymous_N923N,Synonymous_N1003N,Synonymous_N923N,Synonymous_N1003N rs10491590 9 738940 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7027152 9 741001 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12377726 9 742884 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815596 9 743046 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17369029 9 745289 [T/C] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3739586 9 745413 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16923293 9 745502 [A/G] NM_001256876,NM_001354333,NM_001354334,NM_001354331,NM_001354332,NM_015158,NM_001256877,NM_001354335,NM_001354336,NM_001354339,NM_001354337,NM_001354340,NM_001354338,NM_001354344,NR_148869,NM_001354342,NM_153186,NM_001354343,NM_001354341 KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1,KANK1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815610 9 750247 [A/G] rs962817 9 750892 [A/G] rs7865413 9 751359 [T/C] rs12001766 9 751935 [T/G] rs16923428 9 752420 [A/C] rs4742339 9 753218 [A/G] rs7858284 9 754527 [T/C] rs12005362 9 755034 [T/C] rs1885927 9 756415 [A/G] rs1917 9 761569 [T/C] rs6477206 9 761813 [A/C] rs7469926 9 762970 [T/C] rs17436244 9 764128 [T/G] rs11534212 9 770667 [T/C] rs2370197 9 776349 [A/G] rs10976526 9 781115 [A/G] rs10815670 9 783574 [A/G] rs11794001 9 783717 [A/G] rs1853426 9 784064 [T/C] rs16923832 9 786833 [A/G] rs6477235 9 787050 [A/G] rs4742390 9 788730 [A/G] rs10758904 9 791067 [A/C] rs10758905 9 791133 [A/G] rs10481615 9 791858 [T/C] rs17371714 9 792777 [T/C] rs16924003 9 794761 [T/C] rs10815704 9 798773 [A/G] rs7019952 9 800919 [A/G] rs1323267 9 801602 [T/C] rs2370200 9 802801 [A/G] rs4742419 9 804436 [T/C] rs7035551 9 811618 [A/G] rs4742429 9 816742 [T/C] rs10815756 9 818693 [T/C] rs4141756 9 822594 [T/C] rs16924473 9 823287 [A/C] rs16924495 9 824574 [A/G] rs10976808 9 824661 [T/C] rs4742450 9 826701 [A/C] rs4742452 9 828348 [T/C] rs7037561 9 832711 [A/G] rs16924648 9 833828 [A/G] rs17372837 9 839141 [T/C] rs12340997 9 840501 [T/C] rs912062 9 841152 [A/C] rs13295838 9 843382 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 EXON Silent,Silent rs7044108 9 843707 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs4338164 9 843763 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs7862426 9 844001 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs7040024 9 845516 [A/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs16924786 9 846480 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs1407808 9 847292 [T/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs2146532 9 847547 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs4740943 9 853004 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs7029148 9 855091 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10739166 9 857511 [T/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs755383 9 863635 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs749427 9 864122 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs4742515 9 866617 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs4742516 9 866725 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs4538942 9 870027 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs6477322 9 872418 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs7047524 9 874129 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs2370214 9 875364 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs912058 9 875947 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10977244 9 876308 [T/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs1998437 9 877032 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs7875857 9 877871 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10733547 9 880777 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10977270 9 883226 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs16925374 9 892241 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs7859987 9 897949 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs7875002 9 900015 [A/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs2057429 9 902302 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10816007 9 902888 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10977402 9 905068 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs4742545 9 907561 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs2370218 9 907988 [T/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs6477367 9 910485 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs16925796 9 910700 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs1322984 9 916220 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs9299086 9 917214 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs2370220 9 917667 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs11791208 9 923342 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10739185 9 923402 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10977534 9 924525 [T/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10977581 9 930033 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10816063 9 930145 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10816069 9 932251 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10816070 9 932504 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs7863679 9 932875 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10977617 9 934261 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs7856742 9 939156 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10491584 9 939653 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10977752 9 953280 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10759073 9 953465 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10491582 9 953599 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs364477 9 955794 [T/C] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs10123824 9 958073 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs279904 9 960479 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs279903 9 962184 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 Silent,Silent rs4742608 9 969044 [A/G] NM_021951,NM_001363767 DMRT1,DMRT1 EXON Silent,Silent rs408200 9 972476 [T/C] rs279910 9 975112 [A/G] rs279888 9 978833 [A/G] NM_021240 DMRT3 Silent rs12005831 9 985569 [A/G] NM_021240 DMRT3 Silent rs279880 9 986085 [A/G] NM_021240 DMRT3 Silent rs279879 9 987678 [T/C] NM_021240 DMRT3 Silent rs7871877 9 988376 [T/C] NM_021240 DMRT3 Silent rs10978001 9 990076 [A/G] NM_021240 DMRT3 EXON Missense_A164T rs7021244 9 990840 [T/C] NM_021240 DMRT3 EXON Synonymous_V418V rs7047346 9 1000520 [A/G] rs12238866 9 1001309 [T/G] rs7033404 9 1001397 [A/G] rs12343006 9 1002280 [T/C] rs10738147 9 1012154 [T/C] rs1588303 9 1016842 [A/G] rs1509198 9 1019132 [A/G] rs10958885 9 1019207 [T/G] rs10756003 9 1021801 [T/C] rs10738153 9 1022010 [T/C] rs10756006 9 1024471 [A/G] rs4741013 9 1032153 [T/C] rs1016565 9 1032567 [A/G] rs2279989 9 1041524 [A/G] rs2279988 9 1042166 [T/G] rs6474536 9 1043752 [T/C] rs4740448 9 1047343 [A/G] rs7869989 9 1050981 [T/G] NM_006557,NM_001130865,NM_181872 DMRT2,DMRT2,DMRT2 Silent,Silent,Silent rs6474550 9 1052722 [T/G] NM_006557,NM_001130865,NM_181872 DMRT2,DMRT2,DMRT2 Silent,Silent,Silent rs869939 9 1053465 [A/C] NM_006557,NM_001130865,NM_181872 DMRT2,DMRT2,DMRT2 Silent,Silent,Silent rs2275516 9 1053910 [T/G] NM_006557,NM_001130865,NM_181872 DMRT2,DMRT2,DMRT2 Silent,Silent,Silent rs10959107 9 1054991 [A/G] NM_006557,NM_001130865,NM_181872 DMRT2,DMRT2,DMRT2 Silent,Silent,Silent rs7854435 9 1056101 [T/G] NM_006557,NM_001130865,NM_181872 DMRT2,DMRT2,DMRT2 EXON Silent,Silent,Silent rs9140 9 1057318 [A/G] NM_006557,NM_001130865,NM_181872 DMRT2,DMRT2,DMRT2 EXON Silent,Silent,Silent rs4741030 9 1057351 [A/C] NM_006557,NM_001130865,NM_181872 DMRT2,DMRT2,DMRT2 EXON Silent,Silent,Silent rs10809097 9 1057797 [A/G] rs10809101 9 1058914 [A/G] rs10122013 9 1062925 [T/C] rs959481 9 1062999 [A/G] rs7039375 9 1064985 [T/C] rs7857644 9 1069663 [T/C] rs10738171 9 1070591 [T/C] rs12351002 9 1070843 [T/C] rs7043337 9 1071814 [A/G] rs17795247 9 1073148 [T/G] rs10959226 9 1076795 [A/G] rs17641200 9 1077862 [T/C] rs4497022 9 1080866 [A/G] rs7859614 9 1081038 [A/G] rs10809172 9 1081794 [T/C] rs16928735 9 1082486 [A/G] rs10156555 9 1082544 [A/G] rs4741056 9 1085999 [T/C] rs12353456 9 1087874 [T/C] rs7020419 9 1089920 [A/G] rs10738191 9 1090529 [A/G] rs10809197 9 1090566 [T/C] rs10738192 9 1090919 [A/G] rs12335942 9 1093303 [T/C] rs1396633 9 1094644 [T/C] rs1396634 9 1094973 [T/C] rs10959331 9 1095101 [A/G] rs1509186 9 1095922 [A/G] rs1355142 9 1100738 [T/C] rs10809246 9 1102058 [T/C] rs10756149 9 1102943 [T/C] rs10809249 9 1103477 [T/C] rs10118075 9 1107806 [T/C] rs12341902 9 1113854 [T/C] rs4146595 9 1116335 [A/G] rs4741086 9 1117945 [A/C] rs7025111 9 1118896 [A/G] rs10959548 9 1121085 [T/C] rs7861975 9 1121353 [T/C] rs10809358 9 1123530 [T/C] rs4740471 9 1124087 [A/G] rs10809367 9 1125972 [A/G] rs10959588 9 1127279 [T/C] rs7859005 9 1128641 [A/G] rs4237127 9 1129674 [A/G] rs4741117 9 1130580 [A/G] rs10118481 9 1141314 [A/G] rs953166 9 1142276 [A/G] rs2375254 9 1142653 [A/G] rs12553921 9 1152096 [T/C] rs1337619 9 1152396 [A/G] rs10809481 9 1153978 [A/G] rs10738237 9 1158171 [T/C] rs4741151 9 1158199 [A/G] rs10809512 9 1163465 [A/G] rs16930383 9 1164410 [A/G] rs2375256 9 1169485 [A/G] rs2152850 9 1170012 [A/G] rs7848270 9 1170227 [A/G] rs10960072 9 1174357 [T/C] rs1538160 9 1175664 [A/G] rs13297826 9 1183695 [T/C] rs12342237 9 1183870 [T/C] rs10125101 9 1184213 [A/G] rs16930858 9 1185525 [A/G] rs17641744 9 1189365 [A/G] rs1933040 9 1196570 [A/G] rs7029687 9 1197071 [A/G] rs10809638 9 1197632 [T/G] rs10960353 9 1197716 [A/G] rs10809642 9 1199448 [T/C] rs7863802 9 1200011 [A/G] rs10960360 9 1200108 [A/G] rs12341136 9 1200946 [A/G] rs12342106 9 1201156 [A/G] rs10960372 9 1201248 [A/G] rs10809650 9 1202371 [A/G] rs12353067 9 1202824 [T/C] rs16925544 9 1204386 [A/G] rs10960412 9 1207469 [T/G] rs12343642 9 1209190 [T/C] rs10809665 9 1209265 [A/G] rs10809682 9 1213024 [A/G] rs12236917 9 1216007 [A/G] rs3920797 9 1216635 [T/C] rs10809695 9 1218440 [T/C] rs10960472 9 1218605 [T/G] rs10960475 9 1218816 [T/C] rs10960480 9 1219329 [T/C] rs12339290 9 1221729 [T/C] rs6474685 9 1221840 [T/C] rs12345035 9 1222087 [A/G] rs7874807 9 1222118 [A/G] rs10738265 9 1223322 [T/C] rs17709273 9 1230377 [A/G] rs10756345 9 1230994 [T/C] rs10756347 9 1231408 [T/C] rs13293948 9 1235507 [T/G] rs10429609 9 1235703 [A/C] rs945862 9 1235993 [A/G] rs12346252 9 1239644 [A/G] rs4741213 9 1239776 [A/G] rs1556786 9 1241530 [T/C] rs4741218 9 1243842 [T/G] rs9298675 9 1252572 [A/G] rs7851845 9 1256220 [T/C] rs10491875 9 1258510 [T/C] rs7037665 9 1265994 [A/C] rs10809798 9 1267493 [A/C] rs882092 9 1270676 [T/C] rs885043 9 1270931 [A/C] rs1582167 9 1275707 [A/G] rs7871622 9 1279854 [A/G] rs1415612 9 1281453 [A/G] rs10960773 9 1282293 [A/G] rs10809833 9 1283014 [T/C] rs1890810 9 1285567 [A/G] rs7848287 9 1285715 [T/C] rs10960798 9 1288255 [T/G] rs1538157 9 1288320 [T/C] rs7870599 9 1288574 [A/G] rs4314695 9 1290551 [A/G] rs4373571 9 1291196 [T/C] rs9298685 9 1293445 [A/G] rs10122927 9 1294000 [T/C] rs4618752 9 1294441 [T/G] rs16926992 9 1294588 [T/C] rs9969818 9 1294789 [A/C] rs7872312 9 1297287 [A/G] rs1340015 9 1298566 [A/G] rs7021504 9 1303774 [T/G] rs7864098 9 1304815 [A/G] rs1340005 9 1305268 [T/C] rs1340010 9 1308288 [T/C] rs7028809 9 1309997 [T/C] rs4741252 9 1310080 [T/C] rs7048584 9 1310475 [A/G] rs7041725 9 1311050 [T/G] rs16927344 9 1311310 [A/G] rs10809892 9 1315843 [T/G] rs10809893 9 1315952 [T/C] rs7044362 9 1316816 [A/G] rs10960938 9 1317163 [A/G] rs7853956 9 1319316 [A/G] rs17740968 9 1320351 [A/G] rs7869745 9 1321518 [A/G] rs10809905 9 1321793 [A/G] rs10491865 9 1322136 [A/G] rs9792626 9 1322730 [T/G] rs4740541 9 1323164 [T/C] rs1340007 9 1324127 [A/G] rs1538714 9 1324647 [A/G] rs12351304 9 1327672 [A/G] rs16927623 9 1328424 [A/G] rs10491864 9 1328742 [A/G] rs10809918 9 1330623 [A/G] rs7875816 9 1331350 [A/G] rs999924 9 1332257 [A/G] rs10809921 9 1334190 [T/G] rs10960986 9 1334808 [A/G] rs4741290 9 1336460 [T/C] rs7855990 9 1337835 [A/G] rs12345947 9 1339942 [A/G] rs10756470 9 1340735 [T/C] rs10961025 9 1342328 [T/C] rs2226014 9 1342763 [T/C] rs10809943 9 1346388 [A/C] rs12684796 9 1347094 [A/G] rs7037591 9 1347581 [T/G] rs7866259 9 1350453 [T/C] rs7031390 9 1351141 [T/C] rs7021191 9 1353353 [T/C] rs7871293 9 1354036 [T/C] rs12348229 9 1354391 [T/C] rs1412252 9 1355029 [A/G] rs1538721 9 1355061 [A/G] rs10961058 9 1355390 [T/C] rs9406460 9 1356482 [T/C] rs12352331 9 1358025 [A/G] rs682927 9 1358244 [T/G] rs650902 9 1358574 [T/C] rs16928128 9 1360104 [A/G] rs10961113 9 1362503 [A/G] rs2375528 9 1367182 [A/G] rs646785 9 1373944 [T/C] rs12346472 9 1378772 [A/G] rs17743398 9 1383446 [T/C] rs998573 9 1383919 [A/G] rs10961225 9 1385087 [T/C] rs10961233 9 1386018 [A/G] rs627024 9 1387193 [T/C] rs677079 9 1387954 [A/C] rs590938 9 1391887 [A/G] rs10961278 9 1393733 [A/G] rs12341621 9 1399761 [A/G] rs659105 9 1403492 [T/C] rs6474798 9 1403749 [A/C] rs6474799 9 1404008 [T/G] rs12115530 9 1404690 [A/G] rs10810061 9 1405732 [T/C] rs1412248 9 1411571 [A/C] rs7873128 9 1413376 [A/G] rs10119492 9 1413700 [A/G] rs16928755 9 1416909 [T/C] rs10961374 9 1417295 [A/G] rs10120239 9 1417953 [A/G] rs10961410 9 1428059 [A/C] rs10961423 9 1429660 [T/G] rs880013 9 1435496 [T/C] rs876977 9 1436134 [T/C] rs876976 9 1436383 [T/G] rs1412260 9 1438677 [T/G] rs9406475 9 1444746 [T/C] rs604829 9 1446149 [A/G] rs4741361 9 1446459 [A/G] rs10122783 9 1447011 [A/G] rs9407572 9 1448247 [T/C] rs13294519 9 1449084 [A/G] rs10756548 9 1449326 [T/C] rs7037453 9 1450274 [A/C] rs7036822 9 1450428 [A/G] rs1332004 9 1453731 [A/G] rs4142436 9 1454200 [T/C] rs10810165 9 1455409 [T/G] rs10961539 9 1457305 [T/C] rs2210421 9 1460365 [A/C] rs10961548 9 1460427 [A/C] rs10124818 9 1463618 [A/G] rs1339488 9 1463904 [T/C] rs7857963 9 1464762 [A/G] rs10961586 9 1466336 [T/C] rs16929726 9 1468035 [T/C] rs16929773 9 1468923 [A/G] rs7868180 9 1471838 [T/C] rs7041813 9 1472542 [A/G] rs10961637 9 1474523 [A/G] rs10119014 9 1475567 [T/C] rs12343051 9 1481609 [A/G] rs4741416 9 1484527 [A/G] rs7859959 9 1486723 [T/G] rs7864191 9 1487108 [T/C] rs2375535 9 1488208 [T/C] rs10124962 9 1488355 [A/C] rs10961710 9 1488655 [T/G] rs10961719 9 1489454 [T/C] rs7854400 9 1490577 [A/G] rs10810253 9 1490830 [A/C] rs12379509 9 1491213 [A/G] rs10961743 9 1492266 [A/G] rs7846887 9 1495780 [A/C] rs4740589 9 1496230 [A/G] rs10756623 9 1499001 [A/G] rs1331999 9 1499641 [T/G] rs2095023 9 1501815 [A/G] rs10961794 9 1501977 [A/G] rs7025212 9 1502113 [T/C] rs1576748 9 1503356 [A/G] rs955956 9 1505268 [A/G] rs1331998 9 1505457 [A/G] rs10756631 9 1506101 [T/C] rs16930214 9 1507712 [A/G] rs1412254 9 1510230 [A/C] rs10491858 9 1510495 [A/G] rs7872925 9 1510568 [A/G] rs7019932 9 1511184 [T/C] rs9918936 9 1511341 [A/G] rs10961842 9 1512169 [T/G] rs10491857 9 1512232 [T/C] rs10810330 9 1512369 [T/C] rs6474880 9 1513074 [T/C] rs1999435 9 1513849 [T/G] rs2050757 9 1513917 [A/G] rs7855148 9 1516528 [A/C] rs7022816 9 1519043 [A/G] rs10756653 9 1520317 [A/G] rs10961887 9 1520618 [T/G] rs7856537 9 1521178 [T/C] rs9886784 9 1521204 [A/C] rs10961888 9 1521294 [A/G] rs7048299 9 1523296 [A/G] rs10810355 9 1526250 [T/C] rs1888838 9 1526834 [A/G] rs10961907 9 1527191 [A/G] rs10961908 9 1527227 [T/C] rs10961911 9 1527703 [A/G] rs944608 9 1528388 [A/G] rs1114132 9 1533064 [A/C] rs1745886 9 1533757 [T/C] rs1796902 9 1534205 [T/G] rs7046508 9 1538884 [A/G] rs7045593 9 1540499 [A/G] rs7033311 9 1544425 [T/C] rs17723131 9 1550403 [T/C] rs2486442 9 1553462 [A/G] rs771918 9 1554468 [A/G] rs771922 9 1555134 [A/C] rs7873915 9 1556054 [A/G] rs771927 9 1556594 [A/G] rs771667 9 1565742 [A/G] rs12551843 9 1567276 [T/C] rs771663 9 1568904 [T/G] rs771662 9 1568941 [T/C] rs2785727 9 1577505 [T/C] rs7874725 9 1583103 [A/G] rs771912 9 1591811 [A/C] rs7873584 9 1591888 [A/C] rs1923924 9 1592554 [T/C] rs10810459 9 1596030 [T/C] rs1853418 9 1598874 [T/G] rs1853419 9 1599073 [T/C] rs9298744 9 1599200 [T/C] rs10283925 9 1600210 [A/G] rs702160 9 1603814 [A/G] rs1969771 9 1605103 [A/G] rs702167 9 1605827 [A/G] rs702171 9 1606680 [A/G] rs702172 9 1607013 [T/C] rs697047 9 1607940 [A/G] rs702176 9 1610367 [A/G] rs7030942 9 1610861 [A/G] rs702177 9 1614282 [A/G] rs702179 9 1616251 [T/C] rs1535593 9 1616513 [T/G] rs945657 9 1616918 [A/G] rs10962274 9 1617716 [A/C] rs1537966 9 1625303 [A/G] rs12685706 9 1626977 [A/G] rs702188 9 1628468 [A/G] rs771668 9 1629344 [A/G] rs702189 9 1630823 [A/G] rs9407731 9 1632203 [A/G] rs7869423 9 1634618 [T/C] rs2066118 9 1635485 [T/C] rs7871104 9 1637873 [T/G] rs771889 9 1639619 [A/G] rs796424 9 1639935 [A/G] rs7847664 9 1641933 [T/C] rs10126007 9 1644465 [T/C] rs13289158 9 1654030 [A/G] rs771901 9 1654460 [T/C] rs12005872 9 1658021 [T/C] rs10962452 9 1658210 [T/C] rs2181515 9 1659913 [T/C] rs2476245 9 1661432 [A/G] rs2476244 9 1661825 [A/G] rs1885917 9 1663954 [T/C] rs2485175 9 1666693 [A/G] rs10962498 9 1667544 [T/C] rs2485178 9 1667575 [A/C] rs10962501 9 1668272 [A/G] rs12683735 9 1668830 [T/G] rs10962521 9 1674726 [T/C] rs1323235 9 1675540 [A/G] rs4740636 9 1676766 [T/C] rs945663 9 1678482 [A/G] rs10124068 9 1679714 [A/G] rs523006 9 1683466 [T/C] rs10962562 9 1683580 [A/G] rs7868531 9 1685315 [A/G] rs2760397 9 1685649 [A/G] rs10810620 9 1686322 [A/G] rs4740637 9 1688398 [T/C] rs1323243 9 1689357 [T/C] rs12004591 9 1691125 [T/C] rs7039730 9 1697268 [A/C] rs2485153 9 1699307 [A/G] rs10962687 9 1700272 [A/G] rs10962731 9 1702573 [A/G] rs771386 9 1704023 [A/C] rs7852382 9 1705519 [T/C] rs7029758 9 1707496 [A/G] rs12377978 9 1707684 [A/C] rs10962807 9 1708902 [T/C] rs510169 9 1709013 [A/G] rs512774 9 1709308 [A/G] rs7038689 9 1709649 [A/C] rs10962824 9 1711307 [A/G] rs10962829 9 1712303 [T/C] rs7020929 9 1712434 [A/G] rs496867 9 1712474 [A/G] rs574865 9 1712562 [T/C] rs1038050 9 1714233 [T/C] rs508876 9 1715155 [T/C] rs507970 9 1715256 [T/C] rs7020507 9 1715820 [A/G] rs10962856 9 1717031 [A/G] rs2095614 9 1717960 [A/G] rs1809342 9 1718076 [T/C] rs1382183 9 1718324 [A/C] rs2616833 9 1720593 [T/C] rs2616832 9 1720702 [T/G] rs2616829 9 1721778 [T/G] rs10810734 9 1722019 [A/C] rs521124 9 1725777 [T/C] rs10962915 9 1731076 [T/C] rs6475120 9 1732880 [A/G] rs519864 9 1734768 [T/C] rs9298771 9 1739568 [T/G] rs4741586 9 1740278 [T/C] rs2077415 9 1742374 [T/C] rs12344952 9 1745174 [A/G] rs4571782 9 1746224 [A/G] rs4297077 9 1746287 [T/C] rs7849487 9 1757274 [T/G] rs4741603 9 1759486 [A/C] rs12338079 9 1759736 [A/G] rs486815 9 1759811 [T/C] rs10810799 9 1761505 [T/C] rs4741604 9 1762597 [T/C] rs9695411 9 1768866 [A/G] rs10963188 9 1773538 [T/G] rs12340930 9 1775749 [A/G] rs12003026 9 1783885 [T/C] rs7035491 9 1784090 [A/G] rs13288107 9 1784948 [T/C] rs494566 9 1785717 [T/C] rs7028588 9 1786335 [T/C] rs7048135 9 1786681 [T/G] rs3847223 9 1790488 [T/G] rs3847224 9 1790489 [T/C] rs12553036 9 1791880 [A/C] rs2068428 9 1792147 [T/C] rs7852096 9 1793162 [T/C] rs3912096 9 1793408 [A/G] rs10756919 9 1794330 [A/C] rs3847226 9 1795468 [T/C] rs4741606 9 1795548 [A/C] rs7849474 9 1797019 [A/G] rs3847227 9 1798170 [A/G] rs16934185 9 1798324 [A/G] rs3847228 9 1798805 [T/C] rs16934200 9 1799943 [T/C] rs12347707 9 1800027 [T/C] rs3847229 9 1801822 [A/G] rs10810883 9 1809976 [T/C] rs10117983 9 1815727 [T/C] rs10114291 9 1815851 [T/C] rs10756927 9 1816322 [T/G] rs12346108 9 1816832 [T/G] rs1382189 9 1818518 [A/G] rs12686439 9 1826357 [A/G] rs10283612 9 1830286 [A/C] rs10283769 9 1830840 [T/C] rs10963540 9 1835334 [A/G] rs10116883 9 1836746 [A/G] rs10963567 9 1839259 [T/C] rs12005947 9 1840337 [A/C] rs10810952 9 1840933 [A/G] rs7019171 9 1842265 [A/G] rs973493 9 1845151 [T/G] rs7847373 9 1845946 [A/G] rs7019385 9 1849664 [A/G] rs7867368 9 1859272 [T/C] rs7860714 9 1866537 [A/G] rs10963646 9 1866814 [A/G] rs10963648 9 1867013 [T/C] rs10963660 9 1868585 [A/G] rs17724855 9 1872957 [A/G] rs7048797 9 1875165 [A/G] rs7022128 9 1876048 [A/C] rs10963717 9 1876496 [A/G] rs10811009 9 1876592 [A/G] rs7862396 9 1878648 [T/C] rs12336414 9 1881069 [T/C] rs16935270 9 1883292 [T/G] rs10963744 9 1883627 [T/C] rs2039317 9 1884163 [A/G] rs10811026 9 1884934 [A/C] rs4741619 9 1887124 [T/G] rs4741620 9 1887281 [A/G] rs12345586 9 1888205 [T/C] rs10122055 9 1900689 [T/C] rs4741629 9 1908927 [A/G] rs10811093 9 1909586 [A/G] rs4551422 9 1915483 [A/G] rs10811114 9 1919833 [A/G] rs10512035 9 1923359 [A/C] rs7045641 9 1926729 [T/C] rs7047972 9 1945517 [A/G] rs7030343 9 1950813 [A/G] rs10964130 9 1950944 [T/G] rs3935923 9 1953290 [A/G] rs3935922 9 1953536 [A/G] rs7857865 9 1957974 [A/G] rs7020398 9 1958885 [A/C] rs1538533 9 1960788 [A/G] rs10964196 9 1962977 [A/G] rs10757069 9 1963237 [A/G] rs4562384 9 1965945 [T/C] rs4014085 9 1966130 [A/C] rs10118156 9 1968085 [T/G] rs1572748 9 1969329 [T/C] rs16936187 9 1979053 [A/G] rs1416621 9 1979764 [T/C] rs7858803 9 1980819 [A/C] rs7847882 9 1980918 [T/G] rs10120400 9 1981634 [A/G] rs16936230 9 1981979 [A/G] rs7027936 9 1982607 [T/C] rs7864828 9 1989033 [A/G] rs7872017 9 1992516 [A/G] rs10964314 9 1994144 [A/G] rs10964319 9 1994871 [T/G] rs17529312 9 1997332 [T/C] rs7852330 9 1998493 [T/C] rs10119055 9 1999277 [A/G] rs10964337 9 2000062 [A/G] rs4741636 9 2013580 [T/C] rs7040790 9 2013962 [T/G] rs10964427 9 2018825 [A/C] NM_001289397,NM_139045,NM_003070 SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent rs6475412 9 2024076 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs16936751 9 2028237 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10964461 9 2028382 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10964466 9 2028942 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10964471 9 2029199 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 EXON Synonymous_T59T,Synonymous_T59T,Synonymous_T59T,Synonymous_T59T rs7864163 9 2029454 [A/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10114878 9 2030300 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10964500 9 2034440 [A/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs7862617 9 2034908 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs12554293 9 2036252 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10964527 9 2039973 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10964528 9 2039983 [A/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs7865562 9 2040973 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs3793482 9 2042083 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10122060 9 2048361 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs7028212 9 2048876 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs7036529 9 2052014 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs3750417 9 2054409 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs3829069 9 2056563 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs6475447 9 2058133 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs3793486 9 2059341 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10811361 9 2062014 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs7853411 9 2062213 [T/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs7035898 9 2064795 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs13300103 9 2066976 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs12002861 9 2067703 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10121854 9 2068747 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs4741641 9 2072356 [T/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs12348671 9 2072470 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs13288443 9 2073292 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 EXON Synonymous_P609P,Synonymous_P609P,Synonymous_P609P,Synonymous_P609P rs2066111 9 2073839 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs2066110 9 2074070 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs7035071 9 2079250 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10123771 9 2081292 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10811409 9 2089841 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs12349588 9 2090897 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs17725419 9 2091914 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs7851746 9 2094590 [T/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs3793489 9 2095771 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs2275419 9 2097585 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10811426 9 2100396 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10757167 9 2106705 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs12336319 9 2109792 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs1962292 9 2110581 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs3793495 9 2111748 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10511434 9 2114024 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs1572744 9 2115271 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs6475500 9 2116037 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 EXON Synonymous_E1166E,Synonymous_E1224E,Synonymous_E1224E,Synonymous_E1224E rs7020980 9 2116414 [T/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs2001776 9 2120825 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10757185 9 2121371 [T/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10757188 9 2122780 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs7866316 9 2123435 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs3829070 9 2123639 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10811481 9 2124140 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs3829072 9 2127796 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs7847382 9 2128262 [T/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10964907 9 2129798 [T/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs6475524 9 2131534 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10757211 9 2136820 [T/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs13283799 9 2137725 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs7868484 9 2141357 [A/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10811530 9 2142191 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs2376308 9 2143221 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs2376305 9 2143543 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10964978 9 2148213 [A/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10811540 9 2151194 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs17386332 9 2154771 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs3793503 9 2155164 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs7025777 9 2157572 [T/G] NM_001289397,NM_139045,NM_003070,NM_001289396 SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent rs10965030 9 2157934 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent rs3793504 9 2160105 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2274095 9 2161949 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10491695 9 2165758 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3793508 9 2167498 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3829074 9 2167664 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3793514 9 2170884 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16937826 9 2172011 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10965085 9 2172103 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7858891 9 2172726 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7048976 9 2173296 [T/G] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12345422 9 2173478 [A/C] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1886261 9 2173590 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2376230 9 2173752 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10757230 9 2175247 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9298820 9 2177391 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10491697 9 2177492 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1547635 9 2180149 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2281786 9 2182062 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11787578 9 2184301 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7871591 9 2184771 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7860758 9 2184925 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2147263 9 2187750 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10116703 9 2188383 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7859695 9 2190296 [A/G] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10965149 9 2191189 [T/G] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3818384 9 2191246 [T/C] NM_001289397,NM_139045,NM_003070,NM_001289396,NM_001289398,NM_001289399,NM_001289400 SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2,SMARCA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11789313 9 2193975 [A/G] rs4741652 9 2194227 [T/C] rs1535844 9 2194805 [A/G] rs7022827 9 2194911 [T/G] rs10965167 9 2195420 [T/C] rs7865072 9 2195846 [A/G] rs10757258 9 2196183 [T/G] rs1886263 9 2196566 [A/G] rs1886264 9 2196734 [T/C] rs7031622 9 2196932 [T/C] rs7874004 9 2197557 [T/C] rs10965177 9 2198627 [A/G] rs12345888 9 2198823 [A/G] rs7049212 9 2203544 [A/G] rs6475600 9 2203938 [T/C] rs7044370 9 2205924 [A/G] rs10965207 9 2208793 [T/C] rs7026521 9 2208810 [A/G] rs942401 9 2210547 [T/C] rs942402 9 2210583 [T/C] rs7863990 9 2210993 [T/C] rs1535842 9 2212546 [A/G] rs1535841 9 2212574 [A/C] rs7037884 9 2213818 [T/G] rs13440237 9 2214417 [T/C] rs1075039 9 2214693 [A/G] rs12350147 9 2217178 [A/C] rs7025331 9 2220211 [T/C] rs2093833 9 2220796 [T/C] rs10757276 9 2220915 [T/C] rs7858672 9 2224135 [T/G] rs7024071 9 2227217 [T/G] rs10491702 9 2227837 [A/C] rs10491703 9 2227896 [T/C] rs7045699 9 2228689 [A/G] rs10491704 9 2228755 [T/C] rs2093835 9 2229335 [T/G] rs2093836 9 2229436 [A/C] rs4741655 9 2229694 [T/C] rs4741656 9 2231490 [A/G] rs16938096 9 2234069 [T/C] rs942404 9 2234367 [A/C] rs4741657 9 2239429 [T/C] rs10965321 9 2241091 [A/G] rs4741658 9 2241994 [A/G] rs16938123 9 2243374 [A/G] rs2181829 9 2245401 [A/G] rs6475635 9 2247072 [T/C] rs10965339 9 2247904 [T/C] rs7044488 9 2250385 [T/C] rs7041362 9 2250413 [A/G] rs10965349 9 2252454 [T/C] rs10811711 9 2252617 [T/G] rs942397 9 2253087 [A/G] rs942398 9 2253678 [T/G] rs7042935 9 2254498 [A/C] rs1555646 9 2255397 [T/C] rs16938145 9 2256092 [T/C] rs7847256 9 2261052 [T/C] rs10125336 9 2263591 [T/C] rs12552398 9 2264009 [T/G] rs7872273 9 2267871 [A/G] rs7023476 9 2270046 [T/C] rs17471115 9 2270173 [A/G] rs17405547 9 2271325 [T/G] rs12337716 9 2271526 [T/C] rs10811756 9 2272512 [A/G] rs10123928 9 2274492 [A/G] rs7869041 9 2275029 [A/G] rs1324208 9 2282951 [A/G] rs10811770 9 2285443 [A/G] rs9644866 9 2290590 [T/C] rs744216 9 2291635 [T/C] rs6475688 9 2293921 [A/C] rs12001751 9 2295279 [T/C] rs1555644 9 2295503 [A/C] rs12554219 9 2299042 [T/G] rs10965506 9 2299220 [T/G] rs13292475 9 2300565 [T/C] rs12684262 9 2301610 [A/G] rs10965522 9 2301692 [T/C] rs7032999 9 2302693 [T/G] rs7036558 9 2303095 [T/C] rs10965543 9 2305679 [A/G] rs10965569 9 2312205 [T/C] rs10448215 9 2320311 [A/G] rs12553062 9 2321242 [T/C] rs7021419 9 2322572 [T/C] rs12380394 9 2323909 [T/G] rs16938404 9 2324558 [A/G] rs17473202 9 2324646 [A/G] rs1002780 9 2325739 [T/C] rs1571837 9 2329724 [A/C] rs10125660 9 2330643 [A/G] rs1109816 9 2334748 [A/G] rs7871010 9 2337135 [T/C] rs6475728 9 2338786 [A/G] rs4741676 9 2340310 [A/C] rs1331817 9 2342136 [A/G] rs10965875 9 2358639 [T/C] rs4475544 9 2361503 [T/C] rs10123371 9 2361656 [T/C] rs2225500 9 2363667 [A/G] rs2183810 9 2363874 [A/G] rs2889297 9 2374102 [A/G] rs1113842 9 2379343 [A/G] rs1113841 9 2379389 [T/C] rs7031062 9 2379493 [T/C] rs1331824 9 2380408 [A/G] rs1331825 9 2380595 [T/C] rs1023197 9 2381672 [T/C] rs4741690 9 2382247 [T/C] rs11794776 9 2384754 [A/G] rs10491708 9 2385314 [T/G] rs10966074 9 2385584 [A/G] rs4740678 9 2386539 [A/G] rs999644 9 2387137 [T/C] rs1571838 9 2388044 [A/G] rs12342955 9 2388302 [A/G] rs16905627 9 2389032 [A/G] rs10811970 9 2391261 [A/C] rs959379 9 2394917 [T/C] rs7025116 9 2396673 [A/C] rs7870386 9 2397564 [A/G] rs11793711 9 2407101 [A/G] rs7038629 9 2408770 [T/C] rs7030433 9 2409096 [T/G] rs7025994 9 2411572 [T/C] rs1571840 9 2412296 [A/G] rs2376120 9 2414600 [A/G] rs872039 9 2419538 [A/G] rs914491 9 2419927 [A/G] rs16906059 9 2421084 [A/G] rs9696013 9 2421690 [T/C] rs10812032 9 2425428 [A/C] rs10812034 9 2425663 [A/G] rs10966251 9 2426100 [T/G] rs7048743 9 2426985 [A/G] rs10812036 9 2428377 [T/C] rs10757470 9 2428842 [T/C] rs2210396 9 2429859 [T/C] rs2376117 9 2430911 [A/G] rs1155008 9 2431272 [A/C] rs10966259 9 2432562 [A/G] rs2889293 9 2435209 [A/G] rs12338622 9 2437565 [T/C] rs962606 9 2442052 [T/C] rs10757471 9 2447910 [T/G] rs10757474 9 2451856 [T/G] rs10812051 9 2456676 [T/C] rs1158989 9 2459387 [A/G] rs954624 9 2459760 [A/C] rs10491712 9 2460468 [T/C] rs7850160 9 2465097 [T/C] rs10115153 9 2466509 [A/C] rs7859658 9 2468221 [A/G] rs914492 9 2468858 [A/G] rs1331458 9 2469509 [T/C] rs2150720 9 2469742 [A/G] rs4741713 9 2470058 [A/G] rs7041090 9 2472026 [T/C] rs6475804 9 2472410 [A/G] rs2150721 9 2475688 [A/G] rs12352307 9 2476620 [A/G] rs12348238 9 2476954 [A/G] rs2376112 9 2482283 [A/C] rs2889291 9 2482545 [T/G] rs10966459 9 2487356 [T/C] rs10966485 9 2490339 [T/C] rs4237145 9 2493123 [T/C] rs1002393 9 2493381 [T/G] rs1002394 9 2493528 [A/G] rs4559295 9 2495675 [T/C] rs875587 9 2495694 [T/C] rs1571812 9 2495870 [A/C] rs872257 9 2496567 [A/G] rs10812126 9 2499251 [T/C] rs7848645 9 2499273 [T/C] rs6475827 9 2499345 [A/G] rs10812133 9 2500687 [A/G] rs1105016 9 2500856 [T/C] rs17479130 9 2501314 [T/C] rs10812141 9 2503034 [T/G] rs10738699 9 2503549 [T/C] rs944546 9 2505393 [A/G] rs4741719 9 2506794 [T/C] rs4741720 9 2508256 [T/C] rs4741721 9 2508296 [T/C] rs11999258 9 2508727 [A/G] rs1970074 9 2509947 [T/C] rs7042212 9 2515607 [T/G] rs10966757 9 2522475 [A/G] rs4740687 9 2522863 [A/G] rs7864837 9 2524146 [A/G] rs7864942 9 2527980 [A/G] rs7857522 9 2530047 [T/C] rs693007 9 2531098 [T/C] rs963197 9 2533445 [T/C] rs10491717 9 2533850 [A/G] rs10491718 9 2534202 [A/G] rs1996055 9 2534779 [A/G] rs655568 9 2535524 [T/C] rs656414 9 2535695 [A/G] NR_015375 VLDLR-AS1 EXON Silent rs475384 9 2535913 [T/C] NR_015375 VLDLR-AS1 EXON Silent rs2297352 9 2535947 [A/C] NR_015375 VLDLR-AS1 EXON Silent rs499532 9 2536241 [T/C] NR_015375 VLDLR-AS1 Silent rs7864004 9 2536666 [A/G] NR_015375 VLDLR-AS1 Silent rs10812210 9 2536828 [A/C] NR_015375 VLDLR-AS1 Silent rs559776 9 2538201 [A/G] NR_015375 VLDLR-AS1 Silent rs591642 9 2538431 [A/C] NR_015375 VLDLR-AS1 Silent rs13299915 9 2538476 [A/G] NR_015375 VLDLR-AS1 Silent rs2297350 9 2539222 [A/C] NR_015375 VLDLR-AS1 Silent rs482376 9 2539495 [T/C] NR_015375 VLDLR-AS1 EXON Silent rs620949 9 2540365 [A/G] NR_015375 VLDLR-AS1 Silent rs10966854 9 2541567 [T/C] NR_015375 VLDLR-AS1 Silent rs496896 9 2543888 [A/C] NR_015375 VLDLR-AS1 Silent rs1512712 9 2544610 [T/G] NR_015375 VLDLR-AS1 Silent rs4741729 9 2547156 [A/G] NR_015375 VLDLR-AS1 Silent rs4741730 9 2547785 [T/G] NR_015375 VLDLR-AS1 Silent rs4741732 9 2548026 [A/G] NR_015375 VLDLR-AS1 Silent rs1398433 9 2549364 [A/G] NR_015375 VLDLR-AS1 Silent rs520752 9 2550811 [T/C] NR_015375 VLDLR-AS1 Silent rs12348301 9 2551526 [T/G] NR_015375 VLDLR-AS1 Silent rs10966901 9 2551594 [A/G] NR_015375 VLDLR-AS1 Silent rs12340965 9 2557592 [A/G] NR_015375 VLDLR-AS1 Silent rs542859 9 2558513 [T/G] NR_015375 VLDLR-AS1 Silent rs1590979 9 2559492 [T/C] NR_015375 VLDLR-AS1 Silent rs1707299 9 2563876 [T/C] NR_015375 VLDLR-AS1 Silent rs1512715 9 2565685 [T/G] NR_015375 VLDLR-AS1 Silent rs7858086 9 2568043 [A/G] NR_015375 VLDLR-AS1 Silent rs7866017 9 2569631 [T/C] NR_015375 VLDLR-AS1 Silent rs10738726 9 2569655 [A/G] NR_015375 VLDLR-AS1 Silent rs7860538 9 2573499 [T/G] NR_015375 VLDLR-AS1 Silent rs7847026 9 2574919 [T/C] NR_015375 VLDLR-AS1 Silent rs10757565 9 2580421 [A/G] NR_015375 VLDLR-AS1 Silent rs10967052 9 2582380 [T/C] NR_015375 VLDLR-AS1 Silent rs544804 9 2593108 [A/C] NR_015375 VLDLR-AS1 Silent rs986567 9 2593528 [A/G] NR_015375 VLDLR-AS1 Silent rs1454637 9 2596569 [T/C] NR_015375 VLDLR-AS1 Silent rs1156847 9 2596783 [T/G] NR_015375 VLDLR-AS1 Silent rs7040200 9 2597250 [A/G] NR_015375 VLDLR-AS1 Silent rs10812321 9 2598844 [A/G] NR_015375 VLDLR-AS1 Silent rs882259 9 2599564 [T/C] NR_015375 VLDLR-AS1 Silent rs728841 9 2600052 [A/G] NR_015375 VLDLR-AS1 Silent rs729367 9 2600253 [A/G] NR_015375 VLDLR-AS1 Silent rs10812325 9 2602831 [T/C] NR_015375 VLDLR-AS1 Silent rs10812326 9 2603361 [A/G] NR_015375 VLDLR-AS1 Silent rs12350335 9 2605023 [A/G] NR_015375 VLDLR-AS1 Silent rs10812332 9 2607430 [A/G] NR_015375 VLDLR-AS1 Silent rs9969780 9 2614294 [T/C] NR_015375 VLDLR-AS1 Silent rs11790563 9 2616042 [T/C] NR_015375 VLDLR-AS1 Silent rs10967186 9 2617099 [T/C] NR_015375 VLDLR-AS1 Silent rs10967188 9 2617165 [T/G] NR_015375 VLDLR-AS1 Silent rs4741745 9 2618721 [A/G] NR_015375 VLDLR-AS1 Silent rs4741746 9 2618969 [T/C] NR_015375 VLDLR-AS1 Silent rs1454626 9 2621030 [A/C] NR_015375 VLDLR-AS1 Silent rs35209383 9 2621177 [T/G] NR_015375 VLDLR-AS1 Silent rs34881325 9 2622134 [T/C] NR_015375,NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR-AS1,VLDLR,VLDLR,VLDLR,VLDLR EXON Silent,Silent,Silent,Silent,Silent rs2219143 9 2622278 [A/G] NR_015375,NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR-AS1,VLDLR,VLDLR,VLDLR,VLDLR EXON Silent,Silent,Silent,Silent,Silent rs7032549 9 2623615 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs13290598 9 2624433 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs1545565 9 2624874 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs10967213 9 2625172 [T/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs1545568 9 2626313 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs4741748 9 2626851 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs10967228 9 2629324 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs35881329 9 2629328 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs2375994 9 2631092 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs10812378 9 2633460 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs10812379 9 2633548 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs10812380 9 2633562 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs34307867 9 2633921 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs7035616 9 2636161 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs10812382 9 2636492 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs4740698 9 2637551 [T/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs35486699 9 2640605 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs3780181 9 2640759 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs10967306 9 2640805 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs34761707 9 2643496 [A/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR EXON Missense_P262H,Missense_P221H,Missense_P221H,Missense_P262H rs35782329 9 2643832 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs11789583 9 2644954 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs34753566 9 2645651 [A/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR EXON Missense_L464I,Missense_L423I,Missense_L423I,Missense_L464I rs35724190 9 2646530 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR EXON Missense_I561V,Missense_I520V,Missense_I520V,Missense_I561V rs6475888 9 2647760 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs35948251 9 2648223 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR EXON Missense_R613H,Missense_R572H,Missense_R572H,Missense_R613H rs6148 9 2648773 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR EXON Synonymous_Q689Q,Synonymous_Q648Q,Synonymous_Q648Q,Synonymous_Q689Q rs7865617 9 2649217 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs7043949 9 2651809 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs35334949 9 2651909 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR EXON Missense_V763I,Missense_V722I,Missense_V750I,Missense_V791I rs6145 9 2651962 [T/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs17712698 9 2652301 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs35075133 9 2652589 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs34745933 9 2653719 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR Silent,Silent,Silent,Silent rs35412127 9 2653914 [C/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR EXON Silent,Silent,Silent,Silent rs10967349 9 2654402 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR EXON Silent,Silent,Silent,Silent rs8210 9 2654419 [T/C] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR EXON Silent,Silent,Silent,Silent rs7040916 9 2655520 [A/G] NM_001018056,NM_001322226,NM_001322225,NM_003383 VLDLR,VLDLR,VLDLR,VLDLR EXON Silent,Silent,Silent,Silent rs1877480 9 2658311 [T/C] rs11790283 9 2658587 [A/G] rs7045124 9 2661766 [A/C] rs1470943 9 2668085 [A/G] rs4741756 9 2668187 [A/C] rs7859818 9 2674110 [A/G] rs11794349 9 2679427 [A/G] rs10125071 9 2679579 [T/C] rs7870360 9 2681430 [T/C] rs11794855 9 2682322 [T/G] rs10967515 9 2684117 [T/C] rs10738760 9 2691186 [A/G] rs10812474 9 2691446 [A/G] rs10122587 9 2691951 [T/C] rs748786 9 2694436 [T/C] rs930811 9 2696555 [A/G] rs1884441 9 2699004 [A/G] rs7034098 9 2699606 [A/G] rs1454629 9 2700620 [T/C] rs7019428 9 2701429 [A/C] rs7855332 9 2702703 [T/G] rs7032456 9 2704399 [A/G] rs1412693 9 2705874 [T/C] rs897165 9 2710537 [T/C] rs9969833 9 2716921 [A/G] rs7859993 9 2718654 [A/G] NM_133497 KCNV2 EXON Synonymous_V305V rs16909365 9 2720701 [T/C] NM_133497 KCNV2 Silent rs10812526 9 2721249 [A/G] NM_133497 KCNV2 Silent rs12351591 9 2724996 [T/G] NM_133497 KCNV2 Silent rs1006698 9 2725283 [A/C] NM_133497 KCNV2 Silent rs7028045 9 2730819 [T/C] rs10967775 9 2730988 [T/G] rs12352612 9 2731519 [A/G] rs12336382 9 2732014 [T/C] rs13294756 9 2734038 [A/G] rs7048820 9 2735053 [T/C] rs7029249 9 2735415 [A/G] rs1470945 9 2737697 [A/G] rs4741760 9 2739846 [T/C] rs10738768 9 2741196 [A/G] rs2034764 9 2742771 [T/C] rs10967908 9 2744472 [T/C] rs1547501 9 2746270 [A/G] rs10967915 9 2746465 [A/G] rs10812577 9 2746548 [T/C] rs7852307 9 2746594 [T/C] rs1378062 9 2751726 [A/G] rs12352144 9 2752954 [T/G] rs2375957 9 2753505 [A/G] rs7857841 9 2756756 [A/C] rs7854358 9 2759058 [T/C] rs10967974 9 2761993 [A/G] rs958505 9 2762721 [A/C] rs2168134 9 2765753 [T/C] rs1060812 9 2783788 [T/C] rs3739459 9 2783928 [A/G] rs10757686 9 2787856 [A/C] rs1454635 9 2790307 [T/C] rs6476022 9 2795953 [A/G] rs7037204 9 2797082 [A/G] rs870652 9 2800854 [A/C] rs7032686 9 2801858 [T/G] rs12171 9 2804393 [A/G] NM_014878 PUM3 EXON Synonymous_L629L rs7850317 9 2809548 [A/C] NM_014878 PUM3 Silent rs10812738 9 2817887 [A/G] NM_014878 PUM3 Silent rs7861549 9 2824677 [A/G] NM_014878 PUM3 Silent rs10968361 9 2825965 [T/G] NM_014878 PUM3 Silent rs10757715 9 2827752 [T/C] NM_014878 PUM3 Silent rs10125846 9 2831891 [T/C] NM_014878 PUM3 Silent rs10217194 9 2833267 [T/C] NM_014878 PUM3 Silent rs10968457 9 2838470 [T/C] NM_014878 PUM3 EXON Missense_S13N rs10116824 9 2840829 [T/G] NM_014878 PUM3 Silent rs16910644 9 2844261 [A/C] rs4741769 9 2847195 [A/G] rs10123121 9 2848800 [A/G] rs12001239 9 2851026 [T/C] rs7026256 9 2852747 [T/C] rs10968651 9 2864428 [T/C] rs10968653 9 2864819 [T/G] rs7848307 9 2871439 [T/C] rs7037565 9 2890451 [T/C] rs7031610 9 2892642 [A/C] rs13297517 9 2900843 [T/C] rs10968825 9 2901350 [T/G] rs7021223 9 2909883 [A/C] rs10429543 9 2911368 [A/G] rs7865808 9 2913620 [A/G] rs10117905 9 2916741 [T/C] rs1501576 9 2918656 [T/C] rs10969013 9 2929424 [A/G] rs10121692 9 2931315 [T/C] rs13292810 9 2931341 [A/G] rs13285246 9 2932710 [T/C] rs7875771 9 2933001 [T/C] rs10813032 9 2933171 [T/C] rs10114469 9 2933816 [A/G] rs10123521 9 2933896 [A/C] rs10969031 9 2934146 [T/C] rs10156534 9 2936864 [A/G] rs3847230 9 2937654 [T/C] rs10757834 9 2942047 [A/G] rs10813072 9 2949336 [A/G] rs17799828 9 2949580 [T/G] rs7861555 9 2949812 [A/G] rs3913466 9 2951475 [T/G] rs10813084 9 2951623 [A/G] rs3913468 9 2954622 [T/G] rs10122676 9 2957018 [T/C] rs7846783 9 2958182 [A/G] rs10969226 9 2963074 [A/G] rs10969227 9 2963183 [A/G] rs3858034 9 2964750 [A/G] rs10969237 9 2964981 [T/C] rs3858035 9 2968044 [A/C] rs1393037 9 2968451 [A/G] rs12345004 9 2972431 [T/G] rs4741790 9 2977388 [A/G] rs7045640 9 2978377 [A/C] rs7044150 9 2982931 [T/C] rs7033160 9 2984428 [T/C] rs1393040 9 2985743 [A/G] rs3847233 9 2987835 [A/G] rs4741798 9 2989907 [A/G] rs4740708 9 2993975 [T/C] rs7041442 9 2994084 [T/C] rs12340058 9 3005693 [T/C] rs7040143 9 3010878 [A/G] rs4741800 9 3011021 [A/C] rs7855587 9 3011890 [T/G] rs17657377 9 3012175 [T/C] rs7031274 9 3012276 [A/G] rs10123800 9 3012372 [T/C] rs10813222 9 3015465 [A/G] rs4741801 9 3022592 [T/C] rs7033621 9 3030814 [A/G] rs2376770 9 3034077 [T/C] rs7860862 9 3037903 [T/G] rs6476195 9 3044447 [A/G] rs6476196 9 3044503 [A/G] rs3904467 9 3046849 [A/G] rs3904463 9 3049080 [T/G] rs13298031 9 3050066 [T/C] rs2327695 9 3050940 [A/G] rs1332739 9 3058362 [A/G] rs2327717 9 3061261 [T/C] rs4404971 9 3061937 [T/G] rs10757975 9 3064335 [A/G] rs3847252 9 3065603 [A/G] rs2327719 9 3066302 [T/G] rs3904474 9 3070489 [T/C] rs3904473 9 3073208 [T/C] rs7875899 9 3076710 [A/G] rs10511442 9 3077843 [T/C] rs3899009 9 3080838 [A/G] rs11789022 9 3080970 [T/G] rs3847257 9 3081886 [T/G] rs10813363 9 3088774 [A/G] rs17727514 9 3096420 [A/G] rs12377888 9 3096561 [T/C] rs7045303 9 3096871 [A/G] rs7021672 9 3097453 [T/C] rs10120262 9 3097671 [A/C] rs4741806 9 3099009 [A/C] rs10757995 9 3099351 [A/G] rs4364680 9 3100071 [T/C] rs3843576 9 3100566 [A/G] rs17800615 9 3101606 [T/G] rs9696699 9 3101626 [T/C] rs10970000 9 3106474 [A/C] rs2078432 9 3121992 [A/G] rs626533 9 3126263 [A/G] rs506826 9 3128374 [T/C] rs657877 9 3130428 [A/G] rs1571974 9 3131352 [T/C] rs928449 9 3136949 [T/C] rs662562 9 3137117 [A/G] rs494408 9 3140096 [A/C] rs1983765 9 3151278 [T/C] rs10813578 9 3153178 [A/G] rs1570286 9 3154319 [T/C] rs12380711 9 3154726 [A/C] rs10970366 9 3155802 [T/G] rs12236890 9 3157137 [T/C] rs10970390 9 3160003 [A/G] rs10970400 9 3161180 [A/G] rs6476300 9 3168100 [A/G] rs10813625 9 3169779 [T/C] rs1322228 9 3169820 [A/C] rs2380720 9 3170977 [T/C] rs10813628 9 3176796 [T/C] rs7862467 9 3181278 [T/G] rs7036970 9 3182850 [A/G] NR_121585 LINC01231 Silent rs4740717 9 3183137 [T/G] NR_121585 LINC01231 Silent rs10970516 9 3184864 [A/C] NR_121585 LINC01231 Silent rs7875874 9 3184967 [T/G] NR_121585 LINC01231 Silent rs10970529 9 3189170 [T/C] NR_121585 LINC01231 Silent rs10970548 9 3192508 [T/C] NR_121585 LINC01231 Silent rs12342853 9 3192845 [A/G] NR_121585 LINC01231 Silent rs17801047 9 3192985 [A/G] NR_121585 LINC01231 Silent rs1322231 9 3193321 [T/G] NR_121585 LINC01231 Silent rs2093451 9 3193862 [A/G] NR_121585 LINC01231 Silent rs12236127 9 3194613 [A/C] NR_121585 LINC01231 Silent rs4741815 9 3197716 [T/C] NR_121585 LINC01231 Silent rs7873419 9 3202370 [A/G] rs1541125 9 3204080 [A/C] rs10813672 9 3204115 [T/C] rs7868169 9 3207669 [T/G] rs10116401 9 3208361 [T/C] rs580157 9 3208472 [A/C] rs580944 9 3208516 [T/C] rs12006318 9 3209349 [A/C] rs17658489 9 3220602 [C/G] NM_134428,NM_001282116 RFX3,RFX3 EXON Silent,Silent rs1281813 9 3221674 [T/C] NM_134428,NM_001282116 RFX3,RFX3 EXON Silent,Silent rs10813760 9 3223166 [T/C] NM_134428,NM_001282116 RFX3,RFX3 EXON Silent,Silent rs16915985 9 3223441 [A/G] NM_134428,NM_001282116 RFX3,RFX3 EXON Silent,Silent rs687511 9 3225765 [T/C] NM_134428,NM_001282116 RFX3,RFX3 Silent,Silent rs684434 9 3226462 [T/G] NM_134428,NM_001282116 RFX3,RFX3 Silent,Silent rs643429 9 3228700 [A/C] NM_134428,NM_001282116 RFX3,RFX3 Silent,Silent rs16916097 9 3233344 [T/C] NM_134428,NM_001282116 RFX3,RFX3 Silent,Silent rs620745 9 3236394 [A/G] NM_134428,NM_001282116 RFX3,RFX3 Silent,Silent rs832307 9 3237890 [T/C] NM_134428,NM_001282116 RFX3,RFX3 Silent,Silent rs7856125 9 3239762 [T/C] NM_134428,NM_001282116 RFX3,RFX3 Silent,Silent rs515065 9 3242834 [T/C] NM_134428,NM_001282116 RFX3,RFX3 Silent,Silent rs535614 9 3246491 [A/C] NM_134428,NM_001282116 RFX3,RFX3 Silent,Silent rs636548 9 3248543 [T/G] NM_134428,NM_001282116,NM_002919 RFX3,RFX3,RFX3 Silent,Silent,Silent rs12002102 9 3249106 [T/G] NM_134428,NM_001282116,NM_002919 RFX3,RFX3,RFX3 Silent,Silent,Silent rs594370 9 3255945 [T/G] NM_134428,NM_001282116,NM_002919 RFX3,RFX3,RFX3 Silent,Silent,Silent rs502828 9 3262622 [A/G] NM_134428,NM_001282116,NM_002919 RFX3,RFX3,RFX3 Silent,Silent,Silent rs577299 9 3267584 [T/C] NM_134428,NM_001282116,NM_002919 RFX3,RFX3,RFX3 Silent,Silent,Silent rs2304929 9 3277260 [A/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs10511446 9 3277834 [T/C] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs2991328 9 3284500 [T/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs2991288 9 3286217 [T/C] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs2991292 9 3290569 [A/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs2986687 9 3301887 [A/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs7034430 9 3303963 [T/C] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs10971255 9 3306221 [A/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs2986697 9 3307745 [A/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs3012708 9 3322283 [A/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs17659039 9 3326992 [T/C] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs2986676 9 3327260 [A/C] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs12002029 9 3332626 [T/C] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs2991317 9 3332974 [A/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs10971452 9 3334185 [A/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs10121595 9 3335679 [T/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs10971465 9 3338749 [A/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs7036456 9 3344786 [A/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs2991321 9 3345623 [A/C] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs3012675 9 3349487 [T/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs3012677 9 3353579 [A/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs13296217 9 3363069 [T/C] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs10511447 9 3364535 [T/C] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs2920359 9 3370160 [T/C] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs13286511 9 3377723 [T/C] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs12341437 9 3378048 [T/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs1373051 9 3380518 [T/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs9408238 9 3381239 [A/C] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs10971685 9 3384794 [A/C] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs17659225 9 3389223 [T/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs13283163 9 3389660 [A/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs16917918 9 3394094 [T/G] NM_134428,NM_001282116,NM_002919,NM_001282117 RFX3,RFX3,RFX3,RFX3 Silent,Silent,Silent,Silent rs3739461 9 3395848 [T/C] NM_134428,NM_001282116,NM_001282117 RFX3,RFX3,RFX3 Silent,Silent,Silent rs12341737 9 3408858 [A/G] NM_134428,NM_001282116,NM_001282117 RFX3,RFX3,RFX3 Silent,Silent,Silent rs11795111 9 3416639 [A/G] NM_134428,NM_001282116,NM_001282117 RFX3,RFX3,RFX3 Silent,Silent,Silent rs7854273 9 3427166 [T/C] NM_134428,NM_001282116,NM_001282117 RFX3,RFX3,RFX3 Silent,Silent,Silent rs7042511 9 3428971 [T/G] NM_134428,NM_001282116,NM_001282117 RFX3,RFX3,RFX3 Silent,Silent,Silent rs10972006 9 3430684 [T/C] NM_134428,NM_001282116,NM_001282117 RFX3,RFX3,RFX3 Silent,Silent,Silent rs7864440 9 3432447 [T/C] NM_134428,NM_001282116,NM_001282117 RFX3,RFX3,RFX3 Silent,Silent,Silent rs7864459 9 3440355 [T/G] NM_134428,NM_001282116,NM_001282117 RFX3,RFX3,RFX3 Silent,Silent,Silent rs12001407 9 3441334 [A/C] NM_134428,NM_001282116,NM_001282117 RFX3,RFX3,RFX3 Silent,Silent,Silent rs10758256 9 3446277 [T/G] NM_134428,NM_001282116,NM_001282117 RFX3,RFX3,RFX3 Silent,Silent,Silent rs7852899 9 3454967 [A/G] NM_134428,NM_001282116,NM_001282117 RFX3,RFX3,RFX3 Silent,Silent,Silent rs12236983 9 3468075 [T/C] NM_134428,NM_001282116,NM_001282117 RFX3,RFX3,RFX3 Silent,Silent,Silent rs7026025 9 3479911 [A/G] NM_134428,NM_001282116,NM_001282117 RFX3,RFX3,RFX3 Silent,Silent,Silent rs881167 9 3496660 [A/C] NM_134428,NM_001282116 RFX3,RFX3 Silent,Silent rs12340274 9 3500471 [A/C] NM_134428,NM_001282116 RFX3,RFX3 Silent,Silent rs10814189 9 3508131 [A/G] NM_134428,NM_001282116 RFX3,RFX3 Silent,Silent rs7046581 9 3517672 [A/G] NM_134428,NM_001282116 RFX3,RFX3 Silent,Silent rs10814219 9 3536260 [A/C] rs10814233 9 3547259 [T/C] rs951777 9 3573936 [T/C] rs2488292 9 3574369 [T/C] rs7026527 9 3575331 [T/G] rs2184239 9 3576434 [A/G] rs10758318 9 3578094 [T/C] rs10814271 9 3579891 [A/G] rs10758319 9 3579989 [T/C] rs1001388 9 3584207 [T/C] rs1001389 9 3584543 [A/C] rs10972572 9 3585271 [T/C] rs10814278 9 3589867 [T/C] rs10814280 9 3590468 [A/G] rs10814284 9 3593961 [A/G] rs10972598 9 3594049 [T/C] rs7860641 9 3595084 [A/G] rs11787813 9 3599498 [A/G] rs10758333 9 3601355 [A/G] rs1334069 9 3602018 [A/G] rs7856970 9 3603238 [T/C] rs10972661 9 3607242 [T/C] rs9283000 9 3628376 [T/C] rs17728981 9 3631008 [A/G] rs10814372 9 3639538 [T/C] rs10972874 9 3646026 [T/G] rs1537524 9 3649190 [T/C] rs1548299 9 3650174 [A/C] rs12379966 9 3650939 [A/G] rs10814387 9 3651396 [T/G] rs17729056 9 3670015 [A/G] NR_121586 RFX3-AS1 Silent rs2380874 9 3670864 [T/C] NR_121586 RFX3-AS1 Silent rs10511452 9 3673041 [T/C] NR_121586 RFX3-AS1 Silent rs7041297 9 3676408 [T/C] NR_121586 RFX3-AS1 Silent rs7040514 9 3676560 [A/G] NR_121586 RFX3-AS1 Silent rs10973024 9 3677809 [T/G] NR_121586 RFX3-AS1 Silent rs10814428 9 3678039 [T/C] NR_121586 RFX3-AS1 Silent rs10738972 9 3681072 [A/G] NR_121586 RFX3-AS1 Silent rs7040907 9 3684027 [T/C] NR_121586 RFX3-AS1 Silent rs2039470 9 3684635 [A/C] NR_121586 RFX3-AS1 Silent rs11794229 9 3684798 [T/C] NR_121586 RFX3-AS1 Silent rs10758400 9 3686568 [A/G] NR_121586 RFX3-AS1 Silent rs10973079 9 3687942 [A/C] NR_121586 RFX3-AS1 Silent rs7466772 9 3688348 [A/G] NR_121586 RFX3-AS1 Silent rs11789122 9 3689790 [T/C] NR_121586 RFX3-AS1 Silent rs6476583 9 3692923 [A/G] rs10118534 9 3697324 [T/C] rs13283774 9 3698029 [T/G] rs7035633 9 3701629 [A/G] rs7038842 9 3701667 [T/C] rs10511453 9 3701912 [A/G] rs933036 9 3705373 [A/G] rs7872019 9 3707775 [A/G] rs7871296 9 3710068 [T/C] rs7031446 9 3714403 [T/C] rs3954950 9 3716878 [T/C] rs13283466 9 3723221 [A/G] rs4741847 9 3726443 [A/G] rs10973251 9 3729674 [A/C] rs10973279 9 3735490 [A/G] rs7875110 9 3741507 [A/G] rs10511454 9 3743938 [A/C] rs12348858 9 3743985 [T/C] rs7046742 9 3744144 [A/G] rs4147122 9 3746413 [A/C] rs4740731 9 3747376 [T/G] rs1360433 9 3749196 [T/C] rs4626661 9 3755135 [A/G] rs7868939 9 3755938 [A/C] rs11791065 9 3756613 [A/G] rs4740732 9 3756990 [T/C] rs13286706 9 3757758 [A/G] rs2183689 9 3758867 [A/G] rs4740734 9 3761548 [A/G] rs954980 9 3761909 [A/G] rs927584 9 3765198 [T/C] rs6476642 9 3765395 [T/C] rs10814589 9 3772674 [A/G] rs12351927 9 3773699 [A/G] rs1455181 9 3774843 [A/C] rs1455180 9 3775583 [A/G] rs10814596 9 3777523 [A/G] rs10758451 9 3779330 [A/G] rs7039314 9 3781983 [T/C] rs10973533 9 3786161 [A/G] rs7047408 9 3791433 [T/G] rs10973579 9 3793026 [A/G] rs2124210 9 3801316 [A/C] rs7033413 9 3808284 [A/G] rs1537162 9 3809726 [T/C] rs10973640 9 3810196 [T/G] rs7870234 9 3810281 [T/C] rs2380902 9 3817537 [T/C] rs1411880 9 3823277 [A/G] rs7049103 9 3824004 [A/G] rs2297324 9 3825328 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 EXON Silent,Silent rs3739619 9 3825946 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 EXON Silent,Silent rs3739618 9 3826081 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 EXON Silent,Silent rs10116901 9 3826440 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 EXON Silent,Silent rs12376878 9 3826710 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 EXON Silent,Silent rs10973690 9 3827075 [C/G] NM_001042413,NM_152629 GLIS3,GLIS3 EXON Silent,Silent rs1331260 9 3827120 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 EXON Silent,Silent rs734752 9 3827824 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 EXON Silent,Silent rs12001442 9 3828696 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7029652 9 3829212 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs16919734 9 3830772 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs9644834 9 3832812 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7024250 9 3833480 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10973736 9 3838888 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10973737 9 3838929 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs4612398 9 3840882 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs1378325 9 3842939 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10973755 9 3843017 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs12685627 9 3844565 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10973760 9 3845784 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7046660 9 3848687 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs11788034 9 3851002 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10758497 9 3851138 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs4741860 9 3853657 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10758498 9 3854070 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs2281731 9 3855616 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs12338464 9 3861266 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10973877 9 3862693 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7867243 9 3864491 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10739002 9 3865097 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs16919809 9 3865283 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs6476722 9 3866849 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs1475223 9 3869844 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10814737 9 3879097 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10973995 9 3880627 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10973996 9 3880643 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs895229 9 3883042 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs1869690 9 3891863 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs1547127 9 3895172 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10974064 9 3897225 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10122183 9 3898987 [A/G] NM_001042413,NM_152629,NR_026663 GLIS3,GLIS3,GLIS3-AS1 Silent,Silent,Silent rs6476759 9 3900782 [T/C] NM_001042413,NM_152629,NR_026663 GLIS3,GLIS3,GLIS3-AS1 Silent,Silent,Silent rs10974067 9 3900982 [T/C] NM_001042413,NM_152629,NR_026663 GLIS3,GLIS3,GLIS3-AS1 EXON Silent,Silent,Silent rs10974071 9 3901415 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs702268 9 3908403 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs16919945 9 3908583 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs453166 9 3909453 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs519644 9 3910136 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs570649 9 3911976 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10974127 9 3915436 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs487735 9 3920688 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs573520 9 3921040 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs624290 9 3928115 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs681080 9 3931626 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs587571 9 3932521 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs581222 9 3934738 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7870379 9 3935560 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs662234 9 3936301 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs663967 9 3936686 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10974212 9 3937288 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10974235 9 3939705 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs477188 9 3940622 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs12344176 9 3940862 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs564618 9 3940874 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs533520 9 3941973 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs12554821 9 3942136 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs1445339 9 3943449 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs1445338 9 3946361 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs1017568 9 3948365 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs17701244 9 3949244 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs592310 9 3952421 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10974256 9 3952892 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs12238888 9 3957866 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs11791772 9 3958355 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs528938 9 3958518 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10814808 9 3958553 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs16920144 9 3958783 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs2839895 9 3959104 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs635171 9 3961492 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs2182633 9 3962727 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs789263 9 3962983 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs510807 9 3965689 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs509879 9 3965805 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs12552476 9 3967645 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10974265 9 3967758 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs661726 9 3969423 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs663542 9 3969842 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs675148 9 3970103 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7045016 9 3971303 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs585217 9 3971746 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10758547 9 3971787 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs657821 9 3975129 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs627947 9 3981076 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs12351382 9 3981646 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs657076 9 3983003 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7850708 9 3985549 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10814812 9 3985733 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs494215 9 3986123 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs635884 9 3986952 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs12002193 9 3989603 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs500044 9 4002823 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs16920327 9 4005108 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs702263 9 4005592 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs660812 9 4008954 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs474921 9 4012497 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs564816 9 4015370 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10814814 9 4019700 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs627938 9 4020748 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs559433 9 4021386 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs12344339 9 4023999 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs12342127 9 4026129 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs17703489 9 4028842 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs16920428 9 4030806 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs16920433 9 4032693 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs606215 9 4032747 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7853251 9 4034898 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10814817 9 4035710 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs515380 9 4036449 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs16920450 9 4036616 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs571317 9 4037925 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs895236 9 4038228 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs601370 9 4038257 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs2380931 9 4038998 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs614782 9 4039027 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs4741875 9 4039637 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs501461 9 4039727 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs632562 9 4040641 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs676472 9 4043590 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7847440 9 4045796 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs1536468 9 4046569 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs4741877 9 4046886 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10733504 9 4047947 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs6476798 9 4048636 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10814822 9 4050630 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs11791472 9 4051387 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs6476800 9 4051921 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7863393 9 4055471 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10118502 9 4056636 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10974307 9 4058403 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs12350548 9 4058413 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7864487 9 4059114 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7035962 9 4064137 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10758550 9 4065171 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10758551 9 4068002 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs2027394 9 4069657 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs12337254 9 4070648 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7870442 9 4071952 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7019763 9 4076442 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10814830 9 4078864 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs4741887 9 4079470 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs3925024 9 4080699 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7028492 9 4080755 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7875452 9 4080780 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7030223 9 4083297 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7027277 9 4083587 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs6476804 9 4083665 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10814832 9 4084390 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10814834 9 4086370 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs1556987 9 4086553 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs2380935 9 4088131 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7849831 9 4088648 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10814835 9 4088934 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10974326 9 4089046 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10814837 9 4090601 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs17273930 9 4090724 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs2755087 9 4091519 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs484781 9 4093295 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs646827 9 4094202 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs565114 9 4094225 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs564275 9 4094321 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs806034 9 4096451 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs4740750 9 4097131 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs806032 9 4097344 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs487732 9 4099510 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs483774 9 4099988 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs806031 9 4100236 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10974334 9 4102339 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10814843 9 4103200 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10739033 9 4103703 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10974337 9 4103815 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs4741891 9 4104139 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs2064986 9 4106866 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs12345723 9 4109656 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10814846 9 4109906 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10814848 9 4110947 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs537484 9 4117602 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs6415788 9 4118111 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 EXON Missense_P456Q,Missense_P301Q rs13301186 9 4119049 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs806050 9 4121399 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs499357 9 4122302 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs7872188 9 4124377 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs806046 9 4127491 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs1340252 9 4131657 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs806060 9 4133799 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs611698 9 4136715 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs10974343 9 4139276 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs2791757 9 4143590 [A/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs2755084 9 4143674 [T/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs13299873 9 4145545 [A/G] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs13299289 9 4145587 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs6476808 9 4146903 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs982820 9 4149475 [T/C] NM_001042413,NM_152629 GLIS3,GLIS3 Silent,Silent rs927320 9 4156206 [A/G] NM_001042413 GLIS3 Silent rs7026219 9 4157226 [A/G] NM_001042413 GLIS3 Silent rs10758559 9 4159313 [T/G] NM_001042413 GLIS3 Silent rs1983753 9 4160364 [A/G] NM_001042413 GLIS3 Silent rs4741897 9 4162147 [A/G] NM_001042413 GLIS3 Silent rs7847753 9 4163904 [T/C] NM_001042413 GLIS3 Silent rs10758561 9 4165934 [A/G] NM_001042413 GLIS3 Silent rs4740753 9 4169816 [T/C] NM_001042413 GLIS3 Silent rs7853833 9 4170113 [T/C] NM_001042413 GLIS3 Silent rs7865812 9 4170979 [A/C] NM_001042413 GLIS3 Silent rs10739036 9 4171953 [T/C] NM_001042413 GLIS3 Silent rs10974362 9 4172087 [A/G] NM_001042413 GLIS3 Silent rs927316 9 4172899 [T/C] NM_001042413 GLIS3 Silent rs7044458 9 4175223 [A/C] NM_001042413 GLIS3 Silent rs10814856 9 4175324 [T/C] NM_001042413 GLIS3 Silent rs4741904 9 4176178 [T/C] NM_001042413 GLIS3 Silent rs11790620 9 4177109 [T/C] NM_001042413 GLIS3 Silent rs714867 9 4177749 [A/G] NM_001042413 GLIS3 Silent rs2380941 9 4178016 [A/G] NM_001042413 GLIS3 Silent rs7045544 9 4179609 [A/G] NM_001042413 GLIS3 Silent rs16920867 9 4180007 [T/C] NM_001042413 GLIS3 Silent rs10814859 9 4180887 [T/C] NM_001042413 GLIS3 Silent rs13287438 9 4182500 [A/G] NM_001042413 GLIS3 Silent rs7040304 9 4183103 [T/C] NM_001042413 GLIS3 Silent rs10119355 9 4183453 [T/C] NM_001042413 GLIS3 Silent rs10814865 9 4184508 [A/G] NM_001042413 GLIS3 Silent rs10123353 9 4185934 [A/G] NM_001042413 GLIS3 Silent rs10814871 9 4193350 [T/G] NM_001042413 GLIS3 Silent rs4741910 9 4193531 [A/G] NM_001042413 GLIS3 Silent rs10814874 9 4194762 [A/G] NM_001042413 GLIS3 Silent rs7341838 9 4198077 [A/C] NM_001042413 GLIS3 Silent rs4741914 9 4200150 [A/C] NM_001042413 GLIS3 Silent rs10974390 9 4203214 [A/G] NM_001042413 GLIS3 Silent rs2093322 9 4203442 [A/C] NM_001042413 GLIS3 Silent rs2068911 9 4205498 [T/G] NM_001042413 GLIS3 Silent rs7048915 9 4206388 [A/G] NM_001042413 GLIS3 Silent rs6476823 9 4206671 [A/G] NM_001042413 GLIS3 Silent rs6476824 9 4206769 [A/G] NM_001042413 GLIS3 Silent rs7864894 9 4207526 [T/C] NM_001042413 GLIS3 Silent rs7850913 9 4207680 [A/G] NM_001042413 GLIS3 Silent rs10974395 9 4208429 [T/C] NM_001042413 GLIS3 Silent rs7030766 9 4209053 [A/G] NM_001042413 GLIS3 Silent rs12337783 9 4211589 [A/G] NM_001042413 GLIS3 Silent rs12554508 9 4212601 [T/C] NM_001042413 GLIS3 Silent rs13292114 9 4214311 [A/G] NM_001042413 GLIS3 Silent rs12006019 9 4215542 [T/C] NM_001042413 GLIS3 Silent rs736893 9 4217028 [A/G] NM_001042413 GLIS3 Silent rs10758578 9 4218178 [A/G] NM_001042413 GLIS3 Silent rs10121596 9 4218631 [T/G] NM_001042413 GLIS3 Silent rs732957 9 4219259 [T/G] NM_001042413 GLIS3 Silent rs7873463 9 4221298 [A/C] NM_001042413 GLIS3 Silent rs16920948 9 4226502 [T/G] NM_001042413 GLIS3 Silent rs10814891 9 4226630 [T/C] NM_001042413 GLIS3 Silent rs2890551 9 4228550 [T/C] NM_001042413 GLIS3 Silent rs4741926 9 4232824 [A/C] NM_001042413 GLIS3 Silent rs10491551 9 4232871 [A/G] NM_001042413 GLIS3 Silent rs10814895 9 4234586 [T/C] NM_001042413 GLIS3 Silent rs10974406 9 4237041 [T/C] NM_001042413 GLIS3 Silent rs11999791 9 4239545 [A/G] NM_001042413 GLIS3 Silent rs10120959 9 4240743 [T/C] NM_001042413 GLIS3 Silent rs911491 9 4242464 [T/C] NM_001042413 GLIS3 Silent rs911490 9 4243162 [A/G] NM_001042413 GLIS3 Silent rs10739037 9 4244197 [A/C] NM_001042413 GLIS3 Silent rs6476830 9 4257339 [T/C] NM_001042413 GLIS3 Silent rs10122830 9 4258586 [A/G] NM_001042413 GLIS3 Silent rs12378556 9 4261496 [A/G] NM_001042413 GLIS3 Silent rs12380197 9 4262516 [A/G] NM_001042413 GLIS3 Silent rs7037716 9 4265363 [T/C] NM_001042413 GLIS3 Silent rs10974423 9 4265865 [A/G] NM_001042413 GLIS3 Silent rs7045959 9 4267787 [T/G] NM_001042413 GLIS3 Silent rs10511458 9 4269407 [A/G] NM_001042413 GLIS3 Silent rs10814906 9 4270669 [A/G] NM_001042413 GLIS3 Silent rs10758589 9 4270682 [T/C] NM_001042413 GLIS3 Silent rs4740762 9 4272041 [T/C] NM_001042413 GLIS3 Silent rs10758590 9 4277721 [T/C] NM_001042413 GLIS3 Silent rs3892341 9 4283597 [T/G] NM_001042413 GLIS3 Silent rs10974436 9 4284369 [A/G] NM_001042413 GLIS3 Silent rs6476837 9 4287179 [A/C] NM_001042413 GLIS3 Silent rs7034200 9 4289050 [A/C] NM_001042413 GLIS3 Silent rs2380950 9 4289747 [T/G] NM_001042413 GLIS3 Silent rs10116772 9 4290541 [A/C] NM_001042413 GLIS3 Silent rs6476842 9 4291268 [T/C] NM_001042413 GLIS3 Silent rs10974438 9 4291928 [A/C] NM_001042413 GLIS3 Silent rs7043265 9 4292012 [T/C] NM_001042413 GLIS3 Silent rs10758594 9 4295583 [A/G] NM_001042413 GLIS3 Silent rs4741942 9 4300862 [T/C] rs7861665 9 4302988 [T/C] rs7018983 9 4303682 [T/C] rs4740766 9 4304915 [A/G] rs16921094 9 4305320 [A/G] rs10814919 9 4305959 [A/G] rs10814921 9 4307572 [T/C] rs12377521 9 4307589 [T/C] rs10739044 9 4307733 [A/G] rs10974448 9 4308010 [A/C] rs4567095 9 4309006 [T/C] rs12336107 9 4310558 [A/G] rs6476846 9 4311777 [T/C] rs10974450 9 4311864 [T/C] rs6476847 9 4311892 [T/C] rs7038304 9 4314752 [A/G] rs10739046 9 4316336 [A/C] rs10733510 9 4316407 [A/C] rs10814929 9 4316859 [T/G] rs10974453 9 4317128 [T/G] rs12345136 9 4317466 [A/G] rs960485 9 4317825 [T/C] rs10814931 9 4319915 [T/C] rs11789633 9 4321558 [T/C] rs10814934 9 4323880 [A/C] rs10814935 9 4324137 [A/G] rs10758606 9 4326425 [A/G] rs10122246 9 4327048 [T/C] rs10435804 9 4327105 [T/C] rs12351393 9 4327938 [A/G] rs10974470 9 4328940 [A/G] rs10974471 9 4329033 [T/G] rs3895473 9 4329209 [A/G] rs10814941 9 4329354 [A/G] rs10814942 9 4330843 [T/C] rs12378782 9 4331717 [T/C] rs13286735 9 4331760 [A/C] rs4305953 9 4332667 [T/G] rs4741961 9 4334606 [T/C] rs4131424 9 4335668 [A/G] rs10974480 9 4338987 [A/G] rs10814943 9 4340081 [T/C] rs7040026 9 4341704 [T/C] rs4740770 9 4344768 [A/C] rs12376666 9 4345431 [T/G] rs13295703 9 4345557 [A/C] rs10758609 9 4345582 [T/C] rs10974484 9 4347606 [T/C] rs10974487 9 4350760 [A/C] rs10974489 9 4352222 [A/C] rs10814947 9 4356048 [A/G] rs12005536 9 4357693 [T/G] rs4237154 9 4358255 [A/G] rs17741020 9 4359689 [T/C] rs6476853 9 4360058 [T/C] rs4284081 9 4362167 [A/C] rs10758611 9 4362624 [A/G] rs10733512 9 4364108 [T/C] rs4304371 9 4364438 [A/C] rs10739052 9 4366058 [A/C] rs16921207 9 4366159 [T/C] rs10814948 9 4368838 [T/C] rs17717668 9 4371339 [T/C] rs2210105 9 4371844 [T/G] rs6476856 9 4372189 [T/C] rs4741967 9 4374278 [T/C] rs6476858 9 4378727 [A/G] rs3931525 9 4380096 [A/C] rs10115587 9 4380523 [A/G] rs4474078 9 4383219 [A/G] rs10739055 9 4383842 [T/C] rs10739056 9 4384289 [T/C] rs4317631 9 4392649 [A/G] rs10511457 9 4394771 [T/C] rs4401921 9 4400991 [T/C] rs7849712 9 4404373 [T/C] rs4237157 9 4410854 [T/G] rs7851353 9 4411383 [A/G] rs4741985 9 4412152 [A/G] rs10122237 9 4412949 [T/C] rs10758621 9 4413449 [T/C] rs13295153 9 4415824 [A/C] rs4740779 9 4417219 [T/G] rs10974525 9 4417406 [A/G] rs12236350 9 4417649 [T/C] rs10814969 9 4419154 [T/C] rs7039988 9 4420767 [A/G] rs13293594 9 4420971 [A/C] rs4741987 9 4423776 [T/C] rs10974528 9 4423789 [A/G] rs10974530 9 4425033 [T/G] rs16921295 9 4426991 [A/G] rs10974533 9 4428615 [T/C] rs4562386 9 4429166 [T/C] rs10814970 9 4429762 [T/C] rs17753881 9 4430975 [T/C] rs2225360 9 4438240 [T/C] rs10814971 9 4438264 [A/G] rs7874211 9 4438435 [A/G] rs1590929 9 4441054 [A/G] rs4741989 9 4441460 [T/C] rs10974540 9 4442884 [A/G] rs4625083 9 4443086 [T/C] rs7855993 9 4446307 [A/G] rs10814973 9 4447405 [A/G] rs10491737 9 4447601 [T/C] rs10974547 9 4455794 [T/G] rs10814978 9 4456373 [A/G] rs4333659 9 4457091 [A/G] rs7046512 9 4458297 [T/C] rs13297783 9 4458374 [A/G] rs6476867 9 4460786 [T/C] rs7048574 9 4461536 [T/C] rs4741996 9 4462265 [A/G] rs10974552 9 4463421 [T/C] rs954864 9 4476238 [A/G] rs10814983 9 4479464 [T/G] rs4740788 9 4481668 [T/C] rs10491734 9 4482706 [T/C] rs10491733 9 4483189 [T/C] rs2150192 9 4487024 [A/G] rs2183472 9 4487374 [A/G] rs1360329 9 4489494 [T/G] rs7021409 9 4499361 [T/C] NM_004170 SLC1A1 Silent rs10974577 9 4499426 [A/C] NM_004170 SLC1A1 Silent rs7023050 9 4501492 [A/G] NM_004170 SLC1A1 Silent rs10758624 9 4502575 [A/G] NM_004170 SLC1A1 Silent rs10814995 9 4505544 [A/C] NM_004170 SLC1A1 Silent rs16921385 9 4507513 [A/G] NM_004170 SLC1A1 Silent rs10974584 9 4509590 [T/C] NM_004170 SLC1A1 Silent rs7041093 9 4512200 [T/C] NM_004170 SLC1A1 Silent rs10974587 9 4515470 [T/C] NM_004170 SLC1A1 Silent rs12351328 9 4515982 [T/C] NM_004170 SLC1A1 Silent rs17755777 9 4516768 [T/C] NM_004170 SLC1A1 Silent rs10116014 9 4521856 [A/G] NM_004170 SLC1A1 Silent rs7864309 9 4526525 [T/C] NM_004170 SLC1A1 Silent rs4742004 9 4526642 [T/C] NM_004170 SLC1A1 Silent rs10815004 9 4526796 [A/G] NM_004170 SLC1A1 Silent rs6476874 9 4527201 [A/C] NM_004170 SLC1A1 Silent rs17756150 9 4527624 [T/C] NM_004170 SLC1A1 Silent rs6476875 9 4529671 [T/C] NM_004170 SLC1A1 Silent rs7848533 9 4539377 [A/C] NM_004170 SLC1A1 Silent rs10974611 9 4541368 [T/C] NM_004170 SLC1A1 Silent rs16921457 9 4545973 [A/G] NM_004170 SLC1A1 Silent rs10815016 9 4545998 [T/C] NM_004170 SLC1A1 Silent rs10758631 9 4546319 [A/C] NM_004170 SLC1A1 Silent rs10815017 9 4546594 [T/C] NM_004170 SLC1A1 Silent rs10739065 9 4550752 [A/C] NM_004170 SLC1A1 Silent rs7856675 9 4555305 [A/G] NM_004170 SLC1A1 Silent rs3780415 9 4555573 [T/C] NM_004170 SLC1A1 Silent rs10974619 9 4556448 [T/C] NM_004170 SLC1A1 Silent rs4742007 9 4559775 [T/C] NM_004170 SLC1A1 Silent rs10974624 9 4561374 [T/C] NM_004170 SLC1A1 Silent rs9407286 9 4561426 [T/C] NM_004170 SLC1A1 Silent rs2228622 9 4564432 [A/G] NM_004170 SLC1A1 EXON Synonymous_T138T rs7022772 9 4566210 [A/C] NM_004170 SLC1A1 Silent rs11792309 9 4566863 [T/C] NM_004170 SLC1A1 Silent rs7864496 9 4571728 [T/C] NM_004170 SLC1A1 Silent rs3780412 9 4572480 [T/C] NM_004170 SLC1A1 Silent rs301430 9 4576680 [T/C] NM_004170 SLC1A1 EXON Synonymous_T370T rs1471786 9 4576774 [A/G] NM_004170 SLC1A1 Silent rs159914 9 4577130 [T/C] NM_004170 SLC1A1 Silent rs6476879 9 4577346 [A/C] NM_004170 SLC1A1 Silent rs188537 9 4577932 [A/C] NM_004170 SLC1A1 Silent rs301433 9 4580651 [A/G] NM_004170 SLC1A1 Silent rs184204 9 4588577 [T/C] rs16921557 9 4597439 [A/C] NR_148445,NR_148444 SPATA6L,SPATA6L Silent,Silent rs2771 9 4598379 [A/G] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3739642 9 4600804 [T/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780407 9 4602356 [A/G] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12004824 9 4604004 [T/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs301453 9 4604807 [T/G] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4740791 9 4611901 [T/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3824441 9 4615020 [T/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10974657 9 4622453 [T/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L EXON Silent,Silent,Missense_R152G,Missense_R210G,Missense_R243G,Missense_R257G,Missense_R257G,Silent,Missense_R134G,Silent,Missense_R185G,Missense_R120G,Silent,Silent,Missense_R134G rs4742027 9 4629595 [T/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815039 9 4630675 [A/G] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10974672 9 4630762 [T/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815041 9 4633229 [A/G] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10974682 9 4633488 [A/G] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16921669 9 4635232 [A/G] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10974691 9 4636840 [T/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12337028 9 4639262 [T/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10974698 9 4640162 [A/G] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742035 9 4640212 [T/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815044 9 4640712 [A/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815051 9 4644477 [T/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs301468 9 4645935 [A/G] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1385456 9 4651478 [A/G] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs392979 9 4654195 [T/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7869370 9 4655980 [A/G] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2146423 9 4657040 [A/G] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1385452 9 4658449 [T/G] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7047933 9 4659111 [T/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs301489 9 4661853 [T/C] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs301488 9 4662065 [A/G] NR_148445,NR_148444,NM_001353488,NM_001353487,NM_001353486,NM_001353484,NM_001353485,NR_148448,NM_001353489,NR_148443,NM_001039395,NM_001353491,NR_148447,NR_148446,NM_001353490 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs301487 9 4662369 [A/C] NR_148445,NR_148444,NM_001353486,NM_001353484,NM_001353485,NR_148443,NM_001039395,NM_001353491,NR_148446,NM_203453 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,PLPP6 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1485202 9 4664749 [T/C] NR_148445,NR_148444,NM_001353486,NM_001353484,NM_001353485,NR_148443,NM_001039395,NM_001353491,NR_148446,NM_203453 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,PLPP6 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2295963 9 4664852 [A/G] NR_148445,NR_148444,NM_001353486,NM_001353484,NM_001353485,NR_148443,NM_001039395,NM_001353491,NR_148446,NM_203453 SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,SPATA6L,PLPP6 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1385453 9 4671022 [A/G] rs6476893 9 4671409 [A/C] rs10117826 9 4675844 [A/G] rs10974724 9 4677454 [T/G] NR_121597,NR_121598 CDC37L1-DT,CDC37L1-DT Silent,Silent rs7848725 9 4678754 [A/G] NR_121597,NR_121598 CDC37L1-DT,CDC37L1-DT Silent,Silent rs3758244 9 4679304 [G/C] NR_121597,NR_121598 CDC37L1-DT,CDC37L1-DT Silent,Silent rs2295964 9 4679906 [A/G] NM_017913 CDC37L1 Silent rs301486 9 4680653 [A/G] NM_017913 CDC37L1 Silent rs3824440 9 4691570 [T/C] NM_017913 CDC37L1 Silent rs3780397 9 4691765 [A/G] NM_017913 CDC37L1 Silent rs12685759 9 4695004 [A/C] NM_017913 CDC37L1 Silent rs7874378 9 4695068 [A/G] NM_017913 CDC37L1 Silent rs2295970 9 4696919 [T/C] NM_017913 CDC37L1 Silent rs10122598 9 4698594 [A/C] NM_017913 CDC37L1 Silent rs3852397 9 4699811 [T/C] NM_017913 CDC37L1 Silent rs16921877 9 4703921 [A/G] NM_017913 CDC37L1 Silent rs1331191 9 4704420 [A/G] NM_017913 CDC37L1 Silent rs2181341 9 4706214 [T/C] NM_017913 CDC37L1 EXON Silent rs3174298 9 4706366 [T/C] NM_017913 CDC37L1 EXON Silent rs1048020 9 4709784 [A/G] NM_001199853,NM_001199852,NM_001199855,NM_001199856,NM_016282 AK3,AK3,AK3,AK3,AK3 EXON Silent,Silent,Silent,Silent,Silent rs12351140 9 4712407 [A/G] NM_001199853,NM_001199852,NM_001199855,NM_001199856,NM_016282 AK3,AK3,AK3,AK3,AK3 EXON Silent,Silent,Silent,Silent,Silent rs296827 9 4713213 [T/G] NM_001199853,NM_001199852,NM_001199855,NM_001199856,NM_016282 AK3,AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent,Silent rs403860 9 4715847 [T/C] NM_001199853,NM_001199852,NM_001199855,NM_001199856,NM_016282 AK3,AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent,Silent rs12684167 9 4716078 [T/G] NM_001199853,NM_001199852,NM_001199855,NM_001199856,NM_016282 AK3,AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent,Silent rs463684 9 4717365 [A/C] NM_001199853,NM_001199852,NM_001199855,NM_001199856,NM_016282 AK3,AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent,Silent rs7856334 9 4717384 [A/G] NM_001199853,NM_001199852,NM_001199855,NM_001199856,NM_016282 AK3,AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent,Silent rs456374 9 4718907 [T/C] NM_001199853,NM_001199852,NM_001199855,NM_001199856,NM_016282 AK3,AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent,Silent rs465793 9 4718921 [A/C] NM_001199853,NM_001199852,NM_001199855,NM_001199856,NM_016282 AK3,AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent,Silent rs16921966 9 4719031 [A/G] NM_001199853,NM_001199852,NM_001199855,NM_001199856,NM_016282 AK3,AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent,Silent rs458853 9 4720263 [T/C] NM_001199853,NM_001199852,NM_001199855,NM_001199856,NM_016282 AK3,AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent,Silent rs10118291 9 4721900 [A/G] NM_001199853,NM_001199852,NM_001199855,NM_001199856,NM_016282 AK3,AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent,Silent rs2274821 9 4722462 [A/C] NM_001199853,NM_001199852,NM_001199855,NM_001199856,NM_016282 AK3,AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent,Silent rs2039300 9 4725823 [T/C] NM_001199853,NM_001199852,NM_001199855,NM_001199856,NM_016282 AK3,AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent,Silent rs429491 9 4730743 [A/C] NM_001199853,NM_001199852,NM_001199855,NM_016282 AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent rs439486 9 4731040 [T/C] NM_001199853,NM_001199852,NM_001199855,NM_016282 AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent rs12350463 9 4733379 [A/G] NM_001199853,NM_001199852,NM_001199855,NM_016282 AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent rs412899 9 4736508 [T/C] NM_001199853,NM_001199852,NM_001199855,NM_016282 AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent rs435100 9 4737890 [A/C] NM_001199853,NM_001199852,NM_001199855,NM_016282 AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent rs1756867 9 4740648 [T/C] NM_001199853,NM_001199852,NM_001199855,NM_016282 AK3,AK3,AK3,AK3 Silent,Silent,Silent,Silent rs3808857 9 4741883 [T/C] NM_001199853 AK3 Silent rs378117 9 4742323 [A/G] rs12352353 9 4743341 [A/G] rs12352385 9 4743477 [A/C] rs396861 9 4743626 [A/G] rs4742045 9 4746363 [T/G] rs11790285 9 4749459 [A/C] rs10974763 9 4750996 [T/C] rs4742046 9 4751056 [T/G] rs296871 9 4751171 [T/C] rs914285 9 4751227 [T/C] rs10217272 9 4756508 [T/C] rs10123382 9 4757649 [A/G] rs1756871 9 4758022 [A/G] rs12349032 9 4762215 [A/G] rs385893 9 4763176 [T/C] rs409950 9 4763368 [A/C] rs10815074 9 4766022 [T/C] rs420470 9 4767341 [T/C] rs10974772 9 4767677 [T/C] rs407504 9 4769647 [T/C] rs1756875 9 4770942 [T/C] rs296862 9 4773074 [T/C] rs172459 9 4775634 [A/G] rs7025754 9 4784933 [T/C] rs420565 9 4785307 [T/C] rs296854 9 4786985 [A/C] rs4740801 9 4790165 [A/G] rs423955 9 4792339 [T/C] rs10974788 9 4795595 [T/G] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs7851250 9 4796225 [T/C] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs10974795 9 4806233 [T/C] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs10758654 9 4808069 [T/C] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs841986 9 4809158 [T/G] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs377186 9 4819421 [A/G] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs7038267 9 4821348 [A/C] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs16922127 9 4823425 [T/G] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs404464 9 4824003 [T/C] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs7871570 9 4826618 [T/C] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs531122 9 4830849 [A/G] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs439975 9 4832888 [T/C] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs7036729 9 4833305 [A/G] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs458552 9 4833437 [T/C] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs466547 9 4834034 [A/G] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs2296769 9 4834299 [T/G] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs457287 9 4834394 [A/G] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs3780359 9 4835574 [A/G] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs7860776 9 4836566 [A/G] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs10974807 9 4836621 [T/C] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs7861943 9 4836811 [T/C] NM_001286700,NM_005772,NM_001286699 RCL1,RCL1,RCL1 Silent,Silent,Silent rs295263 9 4840063 [T/C] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 Silent,Silent,Silent,Silent rs10815093 9 4842061 [T/C] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 Silent,Silent,Silent,Silent rs2236495 9 4844214 [T/C] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 Silent,Silent,Silent,Silent rs159432 9 4844459 [A/G] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 Silent,Silent,Silent,Silent rs295259 9 4844507 [T/G] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 Silent,Silent,Silent,Silent rs2236497 9 4844704 [T/C] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 Silent,Silent,Silent,Silent rs295258 9 4845242 [A/G] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 Silent,Silent,Silent,Silent rs295254 9 4848630 [A/G] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 Silent,Silent,Silent,Silent rs159433 9 4848875 [T/G] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 Silent,Silent,Silent,Silent rs10115106 9 4851515 [A/G] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 Silent,Silent,Silent,Silent rs12341473 9 4851867 [A/G] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 Silent,Silent,Silent,Silent rs457417 9 4855514 [A/C] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 Silent,Silent,Silent,Silent rs1887430 9 4856234 [A/G] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 Silent,Silent,Silent,Silent rs15583 9 4860300 [A/G] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 EXON Silent,Silent,Silent,Silent rs1260073 9 4860569 [A/G] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 EXON Silent,Silent,Silent,Silent rs295918 9 4860943 [A/G] NM_001286700,NM_005772,NM_001286699,NM_001286701 RCL1,RCL1,RCL1,RCL1 EXON Silent,Silent,Silent,Silent rs4740804 9 4861479 [T/C] rs10758661 9 4863952 [A/G] rs7041623 9 4864891 [A/G] rs7032487 9 4866010 [T/G] rs7850837 9 4866840 [T/C] rs13290894 9 4867085 [A/G] rs10974824 9 4869801 [T/G] rs10815099 9 4876202 [T/C] rs913259 9 4876997 [T/G] rs10117338 9 4883257 [T/C] rs10758662 9 4883937 [T/C] rs12001532 9 4884050 [T/C] rs10117872 9 4888355 [T/C] rs9969783 9 4888441 [A/C] rs10815102 9 4892863 [A/G] rs10974837 9 4895391 [A/G] rs6476919 9 4895668 [T/C] rs7022229 9 4902707 [A/G] rs6476924 9 4903289 [T/G] rs12006302 9 4903818 [T/G] rs10815105 9 4904969 [T/G] rs17803986 9 4905038 [A/G] rs7870918 9 4907617 [A/C] rs2381180 9 4908182 [A/G] rs7864244 9 4909719 [T/C] rs715769 9 4921639 [A/G] rs1410004 9 4921824 [T/C] rs10815121 9 4926113 [T/C] rs7864128 9 4930006 [A/C] rs10974859 9 4930487 [A/C] rs7023498 9 4934896 [T/G] rs10815126 9 4934926 [A/G] rs11792962 9 4935078 [A/C] rs1571221 9 4935926 [T/C] rs16922344 9 4937331 [T/C] rs7025867 9 4937872 [T/C] rs2381181 9 4938232 [T/C] rs1327489 9 4939569 [T/C] rs10974873 9 4943454 [T/C] rs7021993 9 4946989 [T/G] rs7037047 9 4955050 [A/G] rs10974886 9 4956411 [A/G] rs10974888 9 4957902 [T/C] rs7847898 9 4958341 [A/G] rs6476931 9 4959024 [T/C] rs2381194 9 4959331 [A/G] rs10974892 9 4964774 [A/G] rs17662327 9 4967587 [T/C] rs7850675 9 4967950 [A/C] rs7870381 9 4970909 [A/C] rs7862852 9 4972398 [T/C] rs1327495 9 4974441 [A/G] rs1887427 9 4979730 [A/G] rs10758669 9 4981602 [A/C] rs1887429 9 4984549 [T/G] rs2274471 9 4985879 [A/G] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent rs4372063 9 5003338 [A/G] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent rs7030260 9 5008070 [A/C] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent rs11998810 9 5012037 [T/C] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent rs7034753 9 5021514 [A/G] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent rs7851556 9 5022807 [T/C] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent rs1536800 9 5055434 [T/C] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11998913 9 5058048 [A/G] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815149 9 5063701 [T/C] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17490221 9 5072602 [T/A] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 EXON Missense_D584E,Missense_D584E,Missense_D179E,Missense_D584E,Missense_D179E,Missense_D584E,Missense_D435E rs10974947 9 5072846 [A/G] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent VG09S32163 9 5073770 [T/G] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 EXON Missense_V617F,Missense_V617F,Missense_V212F,Missense_V617F,Missense_V212F,Missense_V617F,Missense_V468F rs7034539 9 5081585 [A/G] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2230724 9 5081780 [A/G] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 EXON Synonymous_L830L,Synonymous_L830L,Synonymous_L425L,Synonymous_L830L,Synonymous_L425L,Synonymous_L830L,Synonymous_L681L rs1410779 9 5083173 [T/C] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780372 9 5097544 [T/C] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7870694 9 5100628 [T/C] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780379 9 5112519 [A/G] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs28407218 9 5113313 [A/G] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs36100013 9 5113479 [A/G] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3824433 9 5113577 [T/C] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs884132 9 5114522 [A/G] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12005968 9 5126542 [T/G] NM_001322195,NM_001322194,NM_001322199,NM_001322196,NM_001322198,NM_004972,NM_001322204 JAK2,JAK2,JAK2,JAK2,JAK2,JAK2,JAK2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1410780 9 5140115 [T/C] rs10815167 9 5150058 [A/G] rs10974985 9 5156061 [T/C] rs12003883 9 5162710 [T/C] rs7029084 9 5174638 [T/C] NM_007179 INSL6 Silent rs7047795 9 5181467 [T/C] NM_007179 INSL6 Silent rs7036536 9 5181610 [T/C] NM_007179 INSL6 Silent rs7045342 9 5183892 [T/C] NM_007179 INSL6 Silent rs10758677 9 5188078 [A/G] rs11999802 9 5189773 [T/G] rs2031903 9 5191297 [T/C] rs7037554 9 5191468 [T/C] rs2224571 9 5196253 [A/C] rs16922779 9 5200127 [A/G] rs16922783 9 5200208 [A/G] rs7858039 9 5205920 [A/C] rs10975003 9 5213687 [T/C] rs10975011 9 5223201 [T/C] rs10114531 9 5229116 [A/G] rs2104166 9 5230447 [T/C] rs10118434 9 5238460 [T/C] rs6476953 9 5248742 [T/C] rs1121521 9 5252031 [T/G] rs1121522 9 5252074 [A/G] rs1575284 9 5267043 [T/G] rs16922908 9 5270239 [A/G] rs2381216 9 5270603 [T/C] rs12683801 9 5272381 [T/C] rs7861755 9 5273180 [T/C] rs10975037 9 5274464 [A/G] rs12684204 9 5274648 [A/G] rs2146043 9 5277261 [A/G] rs13288217 9 5277752 [A/G] rs2381217 9 5289943 [A/G] rs10975041 9 5291710 [A/G] rs1407374 9 5292257 [T/C] rs7047392 9 5297563 [A/G] rs10975043 9 5299385 [A/C] rs10975044 9 5302095 [G/C] NM_001329191,NM_134441,NM_005059 RLN2,RLN2,RLN2 Silent,Silent,Silent rs3758239 9 5306824 [A/G] rs4742078 9 5315460 [A/C] rs7848509 9 5317534 [T/C] rs10491649 9 5318770 [A/C] rs4740810 9 5322687 [A/C] rs6476962 9 5324922 [A/G] rs2273782 9 5335470 [T/C] NM_006911 RLN1 EXON Synonymous_Q113Q rs1322220 9 5340596 [T/C] rs12343004 9 5354156 [T/C] rs10815188 9 5354681 [T/C] rs7862502 9 5356333 [A/G] rs10123951 9 5356674 [A/G] rs17429567 9 5357608 [A/G] rs2181146 9 5360293 [T/G] NM_018465 PLGRKT Silent rs2236320 9 5362028 [A/C] NM_018465 PLGRKT Silent rs7874937 9 5364592 [T/C] NM_018465 PLGRKT Silent rs10975080 9 5373441 [A/C] NM_018465 PLGRKT Silent rs10975083 9 5377177 [A/G] NM_018465 PLGRKT Silent rs2381277 9 5381870 [A/G] NM_018465 PLGRKT Silent rs16923101 9 5382192 [A/G] NM_018465 PLGRKT Silent rs7027829 9 5384832 [A/C] NM_018465 PLGRKT Silent rs10815201 9 5385642 [T/G] NM_018465 PLGRKT Silent rs10975086 9 5385783 [T/G] NM_018465 PLGRKT Silent rs10975087 9 5386384 [T/G] NM_018465 PLGRKT Silent rs10815203 9 5389075 [T/C] NM_018465 PLGRKT Silent rs10975090 9 5389652 [T/C] NM_018465 PLGRKT Silent rs3739636 9 5392199 [A/G] NM_018465 PLGRKT Silent rs3739637 9 5392243 [A/G] NM_018465 PLGRKT Silent rs7046325 9 5394099 [A/G] NM_018465 PLGRKT Silent rs10283595 9 5407628 [A/C] NM_018465 PLGRKT Silent rs10283755 9 5407803 [T/C] NM_018465 PLGRKT Silent rs1535453 9 5410624 [T/C] NM_018465 PLGRKT Silent rs1535454 9 5410723 [T/C] NM_018465 PLGRKT Silent rs10815211 9 5412546 [T/C] NM_018465 PLGRKT Silent rs10975105 9 5415874 [T/C] NM_018465 PLGRKT Silent rs11789768 9 5417680 [T/C] NM_018465 PLGRKT Silent rs10815213 9 5418191 [T/C] NM_018465 PLGRKT Silent rs10815214 9 5418334 [T/C] NM_018465 PLGRKT Silent rs10491647 9 5423103 [A/G] NM_018465 PLGRKT Silent rs1322250 9 5435709 [T/C] NM_018465 PLGRKT Silent rs2295870 9 5436461 [A/C] NM_018465 PLGRKT Silent rs911760 9 5438435 [A/C] rs911761 9 5439946 [T/C] rs822349 9 5442487 [T/C] rs4742095 9 5445990 [T/G] rs10975121 9 5446078 [A/G] rs822335 9 5448218 [T/C] rs1329947 9 5449336 [A/C] rs822339 9 5453172 [A/G] NM_014143,NM_001314029,NR_052005,NM_001267706 CD274,CD274,CD274,CD274 Silent,Silent,Silent,Silent rs4742097 9 5455632 [T/C] NM_014143,NM_001314029,NR_052005,NM_001267706 CD274,CD274,CD274,CD274 Silent,Silent,Silent,Silent rs17804441 9 5457733 [T/C] NM_014143,NM_001314029,NR_052005,NM_001267706 CD274,CD274,CD274,CD274 Silent,Silent,Silent,Silent rs10481593 9 5458095 [A/G] NM_014143,NM_001314029,NR_052005,NM_001267706 CD274,CD274,CD274,CD274 Silent,Silent,Silent,Silent rs1411262 9 5459419 [T/C] NM_014143,NM_001314029,NR_052005,NM_001267706 CD274,CD274,CD274,CD274 Silent,Silent,Silent,Silent rs17718883 9 5462876 [G/C] NM_014143,NM_001314029,NR_052005,NM_001267706 CD274,CD274,CD274,CD274 EXON Missense_P146R,Missense_P146R,Silent,Missense_P32R rs10125854 9 5464065 [A/G] NM_014143,NR_052005,NM_001267706 CD274,CD274,CD274 Silent,Silent,Silent rs2890658 9 5465130 [A/C] NM_014143,NR_052005,NM_001267706 CD274,CD274,CD274 Silent,Silent,Silent rs16923173 9 5465262 [A/G] NM_014143,NR_052005,NM_001267706 CD274,CD274,CD274 Silent,Silent,Silent rs2297137 9 5465732 [A/G] NM_014143,NR_052005,NM_001267706 CD274,CD274,CD274 Silent,Silent,Silent rs2297136 9 5467955 [A/G] NM_014143,NR_052005,NM_001267706 CD274,CD274,CD274 EXON Silent,Silent,Silent rs4143815 9 5468257 [C/G] NM_014143,NR_052005,NM_001267706 CD274,CD274,CD274 EXON Silent,Silent,Silent rs4742100 9 5470954 [A/C] rs10815236 9 5483659 [T/C] rs11790653 9 5484418 [T/C] rs10815237 9 5485166 [A/G] rs10122714 9 5485241 [A/G] rs10125503 9 5485307 [A/G] rs1556188 9 5486106 [A/G] rs10435744 9 5486856 [A/G] rs12338205 9 5493994 [A/G] rs7034893 9 5494438 [T/C] rs12376596 9 5497531 [A/G] rs10975148 9 5500300 [A/G] rs10975152 9 5502492 [A/C] rs3808847 9 5509091 [T/C] rs16923189 9 5510644 [A/G] NM_025239 PDCD1LG2 EXON Silent rs16923193 9 5512459 [T/C] NM_025239 PDCD1LG2 Silent rs16923195 9 5512522 [T/G] NM_025239 PDCD1LG2 Silent rs16923198 9 5512786 [A/C] NM_025239 PDCD1LG2 Silent rs1360238 9 5514372 [A/C] NM_025239 PDCD1LG2 Silent rs12001295 9 5518260 [T/C] NM_025239 PDCD1LG2 Silent rs16923201 9 5523773 [T/C] NM_025239 PDCD1LG2 Silent rs4237162 9 5526124 [T/C] NM_025239 PDCD1LG2 Silent rs4742104 9 5532871 [T/C] NM_025239 PDCD1LG2 Silent rs10435814 9 5533831 [T/C] NM_025239 PDCD1LG2 Silent rs10435815 9 5534087 [T/G] NM_025239 PDCD1LG2 Silent rs4143813 9 5534243 [T/C] NM_025239 PDCD1LG2 Silent rs10975175 9 5544405 [A/G] NM_025239 PDCD1LG2 Silent rs7028800 9 5546496 [A/C] NM_025239 PDCD1LG2 Silent rs7869201 9 5551261 [T/C] NM_025239 PDCD1LG2 Silent rs10975176 9 5551385 [A/G] NM_025239 PDCD1LG2 Silent rs7871338 9 5555023 [A/C] NM_025239 PDCD1LG2 Silent rs1009759 9 5556786 [A/G] NM_025239 PDCD1LG2 Silent rs7854413 9 5557708 [T/C] NM_025239 PDCD1LG2 EXON Missense_I241T rs10975179 9 5559893 [T/C] NM_025239 PDCD1LG2 Silent rs7858319 9 5564748 [A/C] NM_025239 PDCD1LG2 Silent rs7031529 9 5568222 [T/C] NM_025239 PDCD1LG2 Silent rs7025291 9 5579041 [A/C] rs7024586 9 5579213 [A/G] rs1536927 9 5581140 [T/G] rs10975190 9 5593419 [T/G] rs7862541 9 5604769 [T/C] rs10815252 9 5607230 [A/G] rs10975196 9 5607774 [A/C] rs7036748 9 5608026 [A/G] rs12342482 9 5609159 [A/C] rs4740819 9 5610320 [T/C] rs4740820 9 5610381 [T/C] rs4740821 9 5610501 [T/C] rs7037208 9 5611912 [A/G] rs10975202 9 5621588 [T/C] rs10122199 9 5625118 [A/G] rs7858030 9 5631097 [T/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs4740823 9 5632721 [A/G] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs7019690 9 5639227 [A/G] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs7860397 9 5644555 [A/G] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs7849484 9 5666181 [T/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs16923368 9 5690079 [A/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs10975244 9 5692233 [T/G] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs2760415 9 5696021 [T/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs16923398 9 5700676 [A/G] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs7047997 9 5703394 [T/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs7028052 9 5703443 [A/G] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs10975255 9 5712626 [A/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs17292138 9 5715597 [A/G] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs10975258 9 5719116 [A/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs10975262 9 5722220 [T/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs10815274 9 5728968 [A/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs4742118 9 5731062 [A/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs4742120 9 5742085 [T/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs7869667 9 5742450 [T/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs10815278 9 5747187 [T/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs10975270 9 5748218 [A/G] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs2031179 9 5750198 [A/G] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs7030124 9 5756067 [T/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs3739646 9 5762600 [A/G] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 EXON Synonymous_R647R,Synonymous_R684R,Synonymous_R684R rs1543527 9 5762894 [A/G] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs754241 9 5765984 [T/C] NM_001206557,NM_020829,NM_001135920 RIC1,RIC1,RIC1 Silent,Silent,Silent rs3739648 9 5774225 [T/G] NM_001206557,NM_020829 RIC1,RIC1 EXON Synonymous_T1380T,Synonymous_T1417T rs16923507 9 5777553 [T/C] rs13287822 9 5784120 [A/G] rs1028702 9 5786850 [A/G] NM_024896 ERMP1 EXON Silent rs1342854 9 5791151 [A/G] NM_024896 ERMP1 Silent rs10975282 9 5792106 [T/C] NM_024896 ERMP1 Silent rs10975283 9 5792156 [A/G] NM_024896 ERMP1 Silent rs3824444 9 5801121 [A/G] NM_024896 ERMP1 Silent rs2797512 9 5807444 [T/G] NM_024896 ERMP1 Silent rs11999400 9 5811658 [T/C] NM_024896 ERMP1 Silent rs10975302 9 5820306 [A/G] NM_024896 ERMP1 Silent rs7861988 9 5820878 [T/C] NM_024896 ERMP1 Silent rs10975303 9 5825768 [A/G] NM_024896 ERMP1 Silent rs10975309 9 5833337 [A/G] rs7047575 9 5841438 [A/G] rs10758710 9 5845105 [T/C] rs4289865 9 5850834 [T/C] rs1418746 9 5854501 [T/C] rs6477005 9 5856209 [T/G] rs7041923 9 5859800 [A/G] rs7044017 9 5861604 [A/G] rs1418742 9 5864988 [T/C] rs4740826 9 5870703 [T/C] rs10115023 9 5872531 [A/G] rs10758713 9 5872949 [A/G] rs10739078 9 5875294 [A/C] rs6477016 9 5875690 [A/C] rs11791517 9 5877948 [T/C] rs10758715 9 5882401 [T/C] rs10758717 9 5884281 [T/C] rs2233173 9 5890270 [T/C] rs2233178 9 5892525 [T/C] NM_005511 MLANA EXON Synonymous_H17H rs1052994 9 5894344 [A/G] NM_005511 MLANA Silent rs10975339 9 5895586 [T/C] NM_005511 MLANA Silent rs7034210 9 5895854 [T/C] NM_005511 MLANA Silent rs16923640 9 5898829 [A/G] NM_005511 MLANA Silent rs4554522 9 5899749 [T/C] NM_005511 MLANA Silent rs10815303 9 5901100 [T/C] NM_005511 MLANA Silent rs1056796 9 5909152 [T/G] NM_005511 MLANA EXON Silent rs1056798 9 5909259 [T/C] NM_005511 MLANA EXON Silent rs10758719 9 5913668 [A/G] rs10975346 9 5915835 [T/C] rs12344502 9 5918374 [A/G] rs17579502 9 5920886 [A/G] NM_001017969 KIAA2026 EXON Missense_L1704F rs1478938 9 5931216 [T/C] NM_001017969 KIAA2026 Silent rs10815311 9 5932616 [T/C] NM_001017969 KIAA2026 Silent rs10975360 9 5939792 [T/C] NM_001017969 KIAA2026 Silent rs12342282 9 5943849 [T/G] NM_001017969 KIAA2026 Silent rs10815315 9 5944012 [T/C] NM_001017969 KIAA2026 Silent rs1984272 9 5956318 [A/G] NM_001017969 KIAA2026 Silent rs13289592 9 5966898 [T/C] NM_001017969 KIAA2026 Silent rs7030731 9 5969517 [T/C] NM_001017969 KIAA2026 Silent rs10815327 9 5971977 [A/G] NM_001017969 KIAA2026 Silent rs7044750 9 5983655 [A/G] NM_001017969 KIAA2026 Silent rs343477 9 6009761 [A/G] rs7425 9 6011335 [T/C] NM_001243202,NM_001243203,NM_012416 RANBP6,RANBP6,RANBP6 EXON Silent,Silent,Silent rs10758736 9 6011757 [A/G] NM_001243202,NM_001243203,NM_012416 RANBP6,RANBP6,RANBP6 EXON Silent,Silent,Silent rs343500 9 6015011 [T/C] NM_001243202,NM_001243203,NM_012416 RANBP6,RANBP6,RANBP6 EXON Silent,Silent,Synonymous_T199T rs6477029 9 6027931 [T/C] rs12378118 9 6033278 [A/G] rs899381 9 6034076 [T/C] rs11506678 9 6040282 [A/C] rs10815345 9 6042708 [A/G] rs10975412 9 6049547 [A/G] rs10975416 9 6051924 [T/G] rs10815347 9 6064103 [A/G] rs10739083 9 6067122 [T/C] rs1478940 9 6068048 [A/C] rs343494 9 6070342 [T/C] rs7872100 9 6071843 [T/C] rs343476 9 6072597 [T/C] rs343473 9 6074936 [A/G] rs340933 9 6085078 [T/G] rs10120134 9 6088457 [A/G] rs4740837 9 6089527 [T/C] rs340892 9 6098662 [T/G] rs340890 9 6100169 [T/C] rs7042561 9 6111473 [A/G] rs10975438 9 6113103 [T/C] rs6477037 9 6118174 [T/C] rs10975444 9 6119329 [A/G] rs693838 9 6122556 [T/C] rs6477040 9 6133074 [T/C] rs376382 9 6134999 [T/C] rs544253 9 6142157 [A/C] rs413382 9 6142948 [A/C] rs10815358 9 6144065 [A/G] rs387149 9 6145022 [T/C] rs12349559 9 6145491 [T/C] rs10975463 9 6149006 [A/G] rs10117792 9 6158778 [T/C] rs10124250 9 6161686 [T/C] rs10119713 9 6163823 [A/G] rs7863536 9 6164771 [A/C] rs2079 9 6166653 [A/G] rs10118918 9 6170162 [T/G] rs4742165 9 6176770 [T/G] rs2890704 9 6184165 [T/C] rs13291323 9 6185360 [T/C] rs1412426 9 6188652 [A/C] rs2150970 9 6201364 [A/G] rs992969 9 6209697 [A/G] rs3939286 9 6210099 [T/C] rs7848215 9 6213468 [T/C] rs2066362 9 6219176 [T/G] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046 IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1891385 9 6219845 [A/C] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046 IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16924144 9 6221246 [T/C] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046 IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11794419 9 6222110 [T/C] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046 IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs996029 9 6222302 [T/G] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046 IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10435816 9 6225535 [A/G] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046 IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2210463 9 6227752 [A/G] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046 IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16924159 9 6229417 [A/G] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046 IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16924161 9 6230912 [T/C] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046 IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12551256 9 6231239 [A/G] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046 IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815388 9 6232242 [T/C] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046 IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975501 9 6233221 [A/C] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046 IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742170 9 6242950 [T/C] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046,NM_001314045 IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7037276 9 6247430 [T/C] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046,NM_001314045 IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975516 9 6247693 [A/G] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046,NM_001314045 IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1330383 9 6251507 [T/G] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046,NM_001314045,NM_001353802 IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975519 9 6253571 [T/C] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046,NM_001314045,NM_001353802 IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33 EXON Synonymous_Y157Y,Synonymous_Y163Y,Synonymous_Y163Y,Synonymous_Y121Y,Synonymous_Y121Y,Synonymous_Y37Y,Synonymous_Y157Y,Synonymous_Y163Y,Synonymous_Y122Y rs1332290 9 6255881 [T/G] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046,NM_001314045,NM_001353802 IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1048274 9 6256292 [A/G] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046,NM_001314045,NM_001353802 IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16924243 9 6257054 [T/C] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046,NM_001314045,NM_001353802 IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12000491 9 6257367 [T/C] NM_001314047,NM_001314044,NM_033439,NM_001314048,NM_001199640,NM_001199641,NM_001314046,NM_001314045,NM_001353802 IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33,IL33 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7861831 9 6264463 [T/C] rs2026991 9 6266440 [A/G] rs10815398 9 6272766 [A/C] rs2169285 9 6280786 [A/G] rs10815402 9 6293715 [A/G] rs17756142 9 6301578 [A/C] rs12237914 9 6306896 [A/G] rs10975539 9 6308729 [T/C] rs16924328 9 6324744 [T/C] rs2295843 9 6328871 [A/G] NM_001001875,NM_001001874,NM_033516 TPD52L3,TPD52L3,TPD52L3 EXON Synonymous_Q92Q,Synonymous_Q92Q,Synonymous_Q92Q rs1052335 9 6330380 [A/C] NM_001001875,NM_001001874,NM_033516 TPD52L3,TPD52L3,TPD52L3 EXON Silent,Silent,Silent rs7035756 9 6331274 [A/G] NM_001001874 TPD52L3 EXON Silent rs2890707 9 6331324 [A/G] NM_001001874 TPD52L3 EXON Silent rs16924356 9 6331610 [A/G] NM_001001874 TPD52L3 EXON Silent rs731585 9 6342328 [A/G] rs2381438 9 6342855 [A/G] rs16924428 9 6351111 [A/G] rs12000850 9 6358174 [T/G] rs7025295 9 6395247 [T/C] rs4742194 9 6401077 [A/G] rs10739097 9 6407843 [T/C] rs10125313 9 6408429 [T/C] rs7042490 9 6412271 [A/G] rs10975580 9 6414839 [A/G] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs10975583 9 6416844 [T/C] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs1156747 9 6423233 [A/G] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs7043824 9 6427721 [T/C] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs4742202 9 6430598 [A/G] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs10739104 9 6432353 [T/G] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs7033570 9 6440123 [A/G] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs12554047 9 6450183 [A/G] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs401733 9 6455048 [T/C] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs524888 9 6459274 [T/C] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs16924591 9 6462585 [T/C] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs12346455 9 6469651 [A/G] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs6477087 9 6472714 [A/C] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs7860627 9 6473630 [A/G] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs10115883 9 6479626 [A/G] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs10739105 9 6490248 [A/G] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs13285035 9 6491371 [T/C] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs16924634 9 6495789 [A/C] NM_152896,NR_046386 UHRF2,UHRF2 Silent,Silent rs33962342 9 6506038 [T/C] NM_152896,NR_046386 UHRF2,UHRF2 EXON Synonymous_C756C,Silent rs36108024 9 6507024 [T/C] NM_152896,NR_046386 UHRF2,UHRF2 EXON Silent,Silent rs10975612 9 6508149 [A/C] rs12350309 9 6523011 [A/G] rs10975629 9 6532344 [A/G] rs7848919 9 6532477 [A/G] NM_000170 GLDC EXON Silent rs2282160 9 6534845 [T/C] NM_000170 GLDC Silent rs2282158 9 6535057 [T/C] NM_000170 GLDC Silent rs3765555 9 6535975 [T/G] NM_000170 GLDC Silent rs12346479 9 6536953 [A/G] NM_000170 GLDC Silent rs12348822 9 6538372 [A/G] NM_000170 GLDC Silent rs6477088 9 6538417 [A/G] NM_000170 GLDC Silent rs4742213 9 6539087 [T/G] NM_000170 GLDC Silent rs2297442 9 6540540 [T/C] NM_000170 GLDC Silent rs4419859 9 6544766 [T/C] NM_000170 GLDC Silent rs12347456 9 6549727 [T/C] NM_000170 GLDC Silent rs16924682 9 6552278 [T/G] NM_000170 GLDC Silent rs4740848 9 6554558 [A/G] NM_000170 GLDC Silent rs1929933 9 6555079 [A/G] NM_000170 GLDC Silent rs10815443 9 6555183 [T/C] NM_000170 GLDC Silent rs10125618 9 6555311 [A/G] NM_000170 GLDC Silent rs10975640 9 6555417 [T/G] NM_000170 GLDC Silent rs4333664 9 6556948 [T/C] NM_000170 GLDC Silent rs7870809 9 6567841 [A/C] NM_000170 GLDC Silent rs10815447 9 6571569 [A/G] NM_000170 GLDC Silent rs10815450 9 6581461 [A/G] NM_000170 GLDC Silent rs16924717 9 6585463 [A/G] NM_000170 GLDC Silent rs7021684 9 6587454 [A/G] NM_000170 GLDC Silent rs11789777 9 6594978 [T/C] NM_000170 GLDC Silent rs7040427 9 6602066 [A/G] NM_000170 GLDC Silent rs7030760 9 6602821 [T/C] NM_000170 GLDC Silent rs7035481 9 6604213 [A/G] NM_000170 GLDC Silent rs10125015 9 6609578 [A/G] NM_000170 GLDC Silent rs10120677 9 6618004 [A/C] NM_000170 GLDC Silent rs10124449 9 6618018 [T/C] NM_000170 GLDC Silent rs2118653 9 6620059 [A/G] NM_000170 GLDC Silent rs2578268 9 6624484 [T/C] NM_000170 GLDC Silent rs2773507 9 6628916 [T/C] NM_000170 GLDC Silent rs934854 9 6631611 [A/G] NM_000170 GLDC Silent rs934855 9 6631702 [T/G] NM_000170 GLDC Silent rs7031908 9 6635045 [A/G] NM_000170 GLDC Silent rs1755606 9 6641802 [A/G] NM_000170 GLDC Silent rs1755617 9 6644932 [T/C] NM_000170 GLDC Silent rs2578286 9 6648607 [T/G] rs2988418 9 6650885 [A/G] rs2578283 9 6652997 [A/G] rs10975714 9 6654000 [T/C] rs11999442 9 6654050 [A/G] rs10815461 9 6654203 [T/C] rs7031325 9 6655056 [T/C] rs10758801 9 6657192 [T/C] rs7868175 9 6658080 [A/G] rs2918182 9 6664282 [A/G] rs1624139 9 6664902 [A/G] rs1658972 9 6665010 [T/C] rs820505 9 6669474 [A/C] rs12347930 9 6673285 [A/G] rs7871969 9 6673465 [T/C] rs10975734 9 6673700 [A/G] rs1759414 9 6673830 [A/C] rs2578275 9 6673957 [A/G] rs12003721 9 6679992 [T/C] rs1759402 9 6680477 [T/G] rs7046643 9 6682871 [A/G] rs17501756 9 6684955 [T/G] rs1094038 9 6695397 [A/C] rs1094039 9 6695472 [T/C] rs1094040 9 6695502 [T/G] rs10739110 9 6697128 [T/C] rs820496 9 6703997 [A/C] rs820493 9 6704475 [A/G] rs2996060 9 6722102 [A/G] NM_001146696 KDM4C Silent rs2990659 9 6722212 [A/G] NM_001146696 KDM4C Silent rs4742247 9 6726613 [T/C] NM_001146696 KDM4C Silent rs2988413 9 6739489 [A/C] NM_001146696 KDM4C Silent rs4008332 9 6743440 [T/C] NM_001146696 KDM4C Silent rs7036872 9 6744721 [T/C] NM_001146696 KDM4C Silent rs16924852 9 6759209 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6477107 9 6760919 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12001316 9 6763072 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975823 9 6764157 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2990658 9 6769653 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7861972 9 6769692 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3858052 9 6770741 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12345872 9 6774846 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2779736 9 6779505 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742263 9 6782225 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11794756 9 6785243 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7031834 9 6786734 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13297144 9 6788085 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975830 9 6790972 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6477109 9 6794938 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11998950 9 6811507 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304341,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12004793 9 6818197 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4740861 9 6818299 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7048549 9 6820190 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7861898 9 6827316 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7038349 9 6830208 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12553351 9 6838348 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10733530 9 6838545 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975841 9 6838925 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7846927 9 6841480 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16924883 9 6845517 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6477117 9 6845561 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975851 9 6846877 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4465021 9 6847072 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742269 9 6849317 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975854 9 6849405 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7018851 9 6850376 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10118127 9 6851118 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12352882 9 6855838 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975858 9 6858156 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12002100 9 6867766 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975867 9 6869872 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12343971 9 6873125 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815473 9 6876538 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs35732562 9 6878215 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2381512 9 6882169 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1417292 9 6883802 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10117958 9 6888611 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7036701 9 6892618 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6477122 9 6895374 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12380608 9 6900255 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7033444 9 6901428 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12349786 9 6905429 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10120163 9 6908557 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12235748 9 6910916 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7018886 9 6915393 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1578324 9 6917477 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975897 9 6917615 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11792447 9 6925663 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7043262 9 6926738 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4740862 9 6928064 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975903 9 6928789 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7031406 9 6932013 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2153498 9 6936215 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975922 9 6940401 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12342436 9 6942605 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11790720 9 6943805 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12683541 9 6944415 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742272 9 6946719 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12351930 9 6947175 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975931 9 6951639 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7019108 9 6953554 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12352785 9 6956850 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7865491 9 6967846 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs702279 9 6969634 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6477134 9 6974101 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2792232 9 6975623 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11791347 9 6978180 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16925027 9 6978321 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1323410 9 6978691 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs818910 9 6982356 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs818909 9 6983331 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815499 9 6984172 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C EXON Synonymous_Q396Q,Silent,Silent,Synonymous_Q374Q,Silent,Silent,Silent,Synonymous_Q374Q,Silent,Synonymous_Q374Q,Synonymous_Q374Q,Synonymous_Q193Q,Silent,Silent,Synonymous_Q374Q rs2296067 9 6984236 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C EXON Missense_D418N,Silent,Silent,Missense_D396N,Silent,Silent,Silent,Missense_D396N,Silent,Missense_D396N,Missense_D396N,Missense_D215N,Silent,Silent,Missense_D396N rs16925068 9 6984781 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2381526 9 6985602 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2381530 9 6986190 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1323398 9 6987663 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2760650 9 6988475 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2760657 9 6990364 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs752646 9 6992425 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7848022 9 6993811 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2760660 9 6993848 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815504 9 6994542 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975955 9 6996653 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7847191 9 6996934 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs818891 9 6997099 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs946929 9 6997639 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11790877 9 6998948 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10122718 9 6999846 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815506 9 7000206 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2792240 9 7000595 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2792238 9 7000769 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs818887 9 7002389 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10975965 9 7004340 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1093707 9 7006539 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs818876 9 7007046 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2890733 9 7008732 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs818879 9 7012612 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NR_130707,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12379204 9 7014879 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs818882 9 7015330 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7853037 9 7017391 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7852014 9 7022554 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12342947 9 7026860 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7045222 9 7027194 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7851112 9 7029050 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10758821 9 7030268 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12554351 9 7032644 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16925141 9 7032930 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7858552 9 7036325 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10976002 9 7038043 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7027561 9 7044255 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1407858 9 7046703 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1417290 9 7046917 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C EXON Missense_K794R,Silent,Missense_K335R,Missense_K772R,Missense_K335R,Missense_K335R,Missense_K772R,Silent,Missense_K772R,Missense_K772R,Missense_K517R,Silent,Silent,Missense_K772R rs7031625 9 7050939 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7019027 9 7051826 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7019042 9 7051859 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3087995 9 7056157 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2381541 9 7057701 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10976011 9 7057742 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10491779 9 7058108 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742295 9 7058374 [A/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10976014 9 7060854 [T/C] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742298 9 7064934 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742299 9 7065141 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742301 9 7065665 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1570508 9 7075305 [T/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1570512 9 7076463 [A/G] NM_001146696,NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001146695,NM_001304340,NR_148680,NR_148677,NM_001353998 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Missense_S782N rs6477148 9 7079643 [T/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16925298 9 7081674 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7863122 9 7081886 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10429452 9 7084213 [A/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10118608 9 7091794 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7033001 9 7092759 [T/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742308 9 7093871 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7849812 9 7094860 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10976036 9 7095864 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17456897 9 7096061 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7861286 9 7097123 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12351031 9 7097281 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13297081 9 7098109 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742309 9 7099205 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16925350 9 7101393 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3763651 9 7103816 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C EXON Silent,Synonymous_D415D,Synonymous_D852D,Synonymous_D415D,Synonymous_D415D,Synonymous_D852D,Silent,Synonymous_D852D,Synonymous_D597D,Silent,Silent rs4740872 9 7105223 [T/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10976040 9 7106795 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7860449 9 7109651 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7861396 9 7109706 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10448243 9 7112808 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7037866 9 7113967 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7023789 9 7117478 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3802401 9 7118990 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1323409 9 7121748 [A/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10758834 9 7122722 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10976050 9 7122872 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10976051 9 7124297 [T/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742314 9 7124815 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7041376 9 7129452 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7033490 9 7130475 [T/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10976056 9 7130628 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12343146 9 7131844 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1535625 9 7132826 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2890741 9 7135196 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2381567 9 7135405 [T/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10758836 9 7135540 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12005620 9 7135716 [T/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10739116 9 7136345 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2224762 9 7137500 [A/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10976062 9 7138349 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815528 9 7139775 [A/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1885975 9 7143431 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12335888 9 7145264 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs722628 9 7146888 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10976070 9 7150975 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs913581 9 7150997 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11789237 9 7153009 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12001158 9 7155356 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7032509 9 7163530 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7046542 9 7163686 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10815532 9 7164061 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10976080 9 7164382 [A/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10511462 9 7166090 [A/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1887870 9 7167481 [T/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10115707 9 7169311 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7022348 9 7170006 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3750489 9 7170121 [T/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3829103 9 7170165 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7040123 9 7170742 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7022054 9 7173500 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7022345 9 7173752 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs913588 9 7174673 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C EXON Silent,Missense_V602I,Silent,Missense_V635I,Missense_V602I,Missense_V1072I,Silent,Missense_V1039I,Missense_V784I,Silent,Silent rs913589 9 7174773 [A/G] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10976088 9 7174813 [T/A] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs913590 9 7174898 [A/C] NR_148678,NM_001354000,NM_001304339,NM_001353999,NM_001354001,NM_001353997,NR_148679,NM_015061,NM_001304340,NR_148680,NR_148677 KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C,KDM4C EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7045956 9 7175734 [T/C] rs2820934 9 7176125 [A/G] rs10976092 9 7177936 [A/G] rs12340864 9 7185027 [A/G] rs1958344 9 7187799 [T/G] rs2820917 9 7192313 [A/G] rs10815541 9 7194214 [A/G] rs10511463 9 7194521 [A/G] rs2820914 9 7195408 [A/G] rs2770759 9 7197023 [T/C] rs2820910 9 7197796 [T/C] rs10976120 9 7201988 [A/G] rs2183118 9 7203306 [A/G] rs16925577 9 7204762 [A/G] rs2770765 9 7205742 [T/C] rs2820898 9 7209258 [A/C] rs12375454 9 7209423 [T/C] rs6477174 9 7210615 [A/G] rs13301012 9 7212446 [A/G] rs10815554 9 7213187 [T/C] rs2183121 9 7214749 [T/C] rs913578 9 7214782 [T/C] rs913579 9 7216180 [A/G] rs10976129 9 7222495 [A/C] rs2149538 9 7222742 [A/C] rs2820957 9 7225030 [T/G] rs10976131 9 7226519 [T/C] rs2770701 9 7226794 [A/G] rs2820956 9 7226997 [A/G] rs10815558 9 7227918 [T/C] rs10120788 9 7231323 [A/G] rs10976135 9 7231559 [T/C] rs7019840 9 7234651 [T/C] rs1018654 9 7236712 [A/G] rs2770705 9 7238701 [A/C] rs12346103 9 7238825 [T/C] rs2381573 9 7239198 [A/C] rs10815565 9 7239370 [A/G] rs10976140 9 7240918 [T/C] rs16925635 9 7241270 [T/G] rs16925637 9 7242537 [A/G] rs11794497 9 7244151 [A/G] rs2820962 9 7244823 [A/G] rs7028940 9 7245009 [A/G] rs2770710 9 7245314 [T/C] rs10976145 9 7245681 [T/C] rs12551734 9 7248916 [A/G] rs7856490 9 7250826 [A/C] rs4742321 9 7255930 [A/G] rs966015 9 7257213 [A/G] rs10976157 9 7257340 [T/C] rs2494244 9 7258526 [A/G] rs10976161 9 7259614 [A/G] rs2820950 9 7260390 [T/C] rs2770719 9 7263472 [A/G] rs2820949 9 7264558 [A/G] rs10976166 9 7266283 [A/G] rs4740874 9 7267176 [T/C] rs10733533 9 7267702 [T/C] rs1928199 9 7270158 [A/G] rs1928200 9 7270363 [T/G] rs2820944 9 7272542 [T/C] rs7859003 9 7272552 [T/C] rs10815578 9 7273950 [A/G] rs1887867 9 7274696 [T/C] rs17528044 9 7275995 [A/C] rs4486259 9 7276387 [T/C] rs7034160 9 7276798 [A/G] rs10815582 9 7284763 [T/C] rs10758855 9 7285207 [A/C] rs2770725 9 7285885 [T/C] rs10976178 9 7286273 [T/C] rs4742322 9 7286599 [T/G] rs10976182 9 7291256 [T/C] rs10976183 9 7291584 [T/C] rs10758857 9 7291611 [A/G] rs11794291 9 7295783 [A/G] rs10815583 9 7296644 [T/C] rs16925803 9 7301900 [T/C] rs7039269 9 7304762 [A/G] rs10815590 9 7309750 [A/G] rs7034937 9 7313773 [T/C] rs12380136 9 7313822 [T/G] rs12006541 9 7315798 [T/C] rs12555938 9 7316085 [A/G] rs1926393 9 7316589 [T/C] rs7028391 9 7319116 [A/G] rs10976233 9 7320871 [A/G] rs10976239 9 7321919 [T/C] rs2148348 9 7325093 [T/C] rs1926387 9 7328880 [A/G] rs7873956 9 7330152 [A/G] rs10976248 9 7335597 [T/C] rs731253 9 7335949 [A/C] rs12347615 9 7336443 [A/G] rs6477186 9 7338263 [A/G] rs7035555 9 7338345 [T/C] rs12351222 9 7338432 [T/G] rs10976253 9 7338609 [T/C] rs1926381 9 7339425 [A/G] rs10815597 9 7340826 [A/G] rs6477187 9 7341123 [T/G] rs12005581 9 7341260 [A/G] rs7856288 9 7342059 [A/G] rs17601822 9 7342797 [A/G] rs1952178 9 7343188 [T/C] rs1926380 9 7343325 [A/C] rs1926379 9 7344034 [A/G] rs10511465 9 7346029 [T/C] rs746084 9 7347596 [A/G] rs9695318 9 7348292 [A/G] rs7024562 9 7348662 [T/G] rs10976259 9 7351874 [A/G] rs1926374 9 7355129 [A/C] rs12554101 9 7357693 [T/G] rs4742336 9 7360902 [T/C] rs10976265 9 7361202 [T/G] rs7853490 9 7366297 [A/G] rs7869986 9 7366709 [A/G] rs7849548 9 7370679 [T/C] rs11792571 9 7370794 [T/G] rs1926363 9 7371646 [T/G] rs1926361 9 7372732 [T/C] rs4740882 9 7373020 [A/G] rs4740884 9 7373868 [A/C] rs7865621 9 7374332 [A/C] rs7865746 9 7374476 [A/C] rs7855413 9 7375169 [A/G] rs1926359 9 7375925 [A/G] rs4360345 9 7378095 [A/G] rs7871958 9 7379168 [A/G] rs7872098 9 7379273 [A/C] rs16925989 9 7381341 [T/C] rs6477190 9 7381520 [A/G] rs6477191 9 7382274 [T/C] rs7862635 9 7382363 [A/G] rs10976270 9 7383445 [T/G] rs12684148 9 7383823 [A/G] rs7041418 9 7387537 [T/C] rs7041546 9 7387603 [T/C] rs10815605 9 7387954 [T/C] rs4742341 9 7388656 [A/G] rs10815606 9 7390508 [A/C] rs7862381 9 7391634 [A/G] rs10120589 9 7391855 [A/G] rs7033457 9 7393934 [T/C] rs2148356 9 7395038 [A/G] rs4740888 9 7396956 [T/C] rs943174 9 7399175 [A/G] rs4620331 9 7400754 [T/C] rs7467398 9 7402208 [A/G] rs943172 9 7403305 [A/G] rs2997547 9 7405366 [A/G] rs2997552 9 7405911 [T/G] rs2997578 9 7408763 [A/G] rs2997584 9 7411160 [A/G] rs1926415 9 7413841 [T/C] rs1926410 9 7415094 [T/G] rs2997544 9 7415340 [T/G] rs16935865 9 7416419 [T/A] rs1926403 9 7426221 [A/G] rs13294039 9 7436205 [T/C] rs7857046 9 7437070 [T/C] rs7875445 9 7437154 [T/C] rs2997550 9 7446748 [A/C] rs16926110 9 7448042 [T/C] rs16926115 9 7448841 [T/G] rs2997564 9 7454698 [T/G] rs2997565 9 7454719 [A/G] rs2997573 9 7462598 [T/C] rs2803469 9 7465205 [T/C] rs1926389 9 7467366 [T/C] rs2986261 9 7467934 [A/G] rs943170 9 7468664 [T/C] rs2986262 9 7468720 [A/C] rs1926371 9 7470753 [T/G] rs1887084 9 7472554 [A/G] rs2381609 9 7472661 [T/C] rs2986267 9 7473692 [A/G] rs10124650 9 7474066 [T/G] rs2986276 9 7478718 [T/C] rs7866956 9 7480873 [A/G] rs10976314 9 7485142 [A/C] rs16926236 9 7487847 [A/C] rs10976317 9 7487974 [A/G] rs10815617 9 7489047 [T/C] rs4742351 9 7489720 [T/C] rs16926241 9 7491136 [T/C] rs10119703 9 7493198 [T/C] rs2381616 9 7496902 [T/C] rs10119450 9 7497427 [A/C] rs7029335 9 7497932 [A/G] rs17613065 9 7500653 [A/C] rs12553976 9 7500665 [T/C] rs7019330 9 7500955 [A/G] rs10815619 9 7501258 [A/G] rs4329320 9 7503054 [T/C] rs7021631 9 7503994 [T/C] rs7853724 9 7504790 [T/C] rs7041658 9 7505644 [T/C] rs1986733 9 7505902 [A/G] rs12237671 9 7506212 [T/C] rs4740890 9 7508229 [T/G] rs17613887 9 7510496 [A/G] rs7019104 9 7510851 [A/C] rs10511474 9 7511166 [T/C] rs7873050 9 7512186 [T/G] rs2381623 9 7512409 [T/C] rs10511475 9 7512595 [A/G] rs10511476 9 7512610 [A/G] rs17542133 9 7512820 [A/C] rs2381624 9 7513175 [A/G] rs10758869 9 7513262 [A/G] rs10511478 9 7514442 [T/C] rs10511479 9 7514825 [T/C] rs4623493 9 7515370 [T/C] rs2381626 9 7517429 [T/G] rs2381628 9 7518656 [T/C] rs7466961 9 7519263 [A/G] rs7865752 9 7520035 [T/C] rs12352345 9 7520697 [T/C] rs7870059 9 7521177 [T/C] rs4606115 9 7521577 [T/C] rs10976357 9 7530883 [T/C] rs7025720 9 7532386 [T/C] rs4740893 9 7533050 [A/G] rs4742366 9 7533529 [T/C] rs6477214 9 7534603 [T/C] rs10815631 9 7535872 [T/C] rs2890755 9 7539001 [A/G] rs10976375 9 7539474 [T/C] rs2381635 9 7539567 [T/C] rs12349302 9 7540496 [T/G] rs7849878 9 7541338 [T/G] rs10976380 9 7541473 [A/G] rs12348699 9 7542487 [T/C] rs10976384 9 7542967 [A/G] rs12353094 9 7543336 [A/G] rs10739135 9 7544922 [A/C] rs4742374 9 7546436 [T/C] rs2381634 9 7547443 [A/G] rs4740896 9 7557664 [T/C] rs7855527 9 7558182 [A/G] rs4400445 9 7558261 [T/C] rs10976396 9 7558769 [T/C] rs12376869 9 7560568 [T/C] rs2381640 9 7560779 [T/C] rs4740897 9 7561271 [T/C] rs10117858 9 7561756 [T/C] rs2381642 9 7563692 [A/G] rs10815639 9 7567326 [A/G] rs725988 9 7570610 [A/G] rs10117057 9 7577893 [A/G] rs4742378 9 7578222 [T/C] rs1485184 9 7579004 [A/G] rs2381645 9 7580951 [A/G] rs4742380 9 7581533 [T/G] rs10976420 9 7582234 [T/C] rs7873807 9 7582632 [A/G] rs7873817 9 7582673 [A/G] rs7036891 9 7583375 [A/G] rs4740900 9 7584003 [A/G] rs10125595 9 7585382 [T/C] rs1385447 9 7585409 [T/C] rs10976421 9 7587282 [A/G] rs4740901 9 7587716 [A/C] rs10758888 9 7591465 [A/G] rs3852399 9 7592407 [A/G] rs16926462 9 7601812 [A/G] rs11790721 9 7602153 [A/C] rs10815645 9 7604410 [A/C] rs10976444 9 7606348 [T/C] rs10815647 9 7607425 [T/C] rs10976450 9 7612143 [T/C] rs10976453 9 7613834 [A/C] rs10815648 9 7617978 [T/C] rs3912454 9 7625060 [A/C] rs7867163 9 7633155 [T/C] rs10976463 9 7636050 [A/G] rs7865284 9 7636071 [A/G] rs1564845 9 7638453 [T/C] rs10976470 9 7641251 [A/C] rs7864806 9 7641620 [A/G] rs3005752 9 7642033 [T/G] rs10976473 9 7646850 [T/C] rs2930713 9 7649442 [T/G] rs2930724 9 7656388 [T/G] rs2930727 9 7656826 [T/C] rs2930732 9 7658953 [A/G] rs2930736 9 7662501 [T/C] rs10976483 9 7662660 [A/C] rs11792985 9 7664428 [A/G] rs10976486 9 7665194 [T/C] rs9942919 9 7665856 [A/G] rs3005761 9 7666387 [T/C] rs3124028 9 7668843 [T/G] rs10815654 9 7672125 [A/G] rs10976492 9 7673654 [A/G] rs7046958 9 7677811 [A/G] rs936769 9 7681711 [T/C] rs10976498 9 7682063 [T/G] rs842304 9 7682601 [A/C] rs4740904 9 7682860 [A/G] rs328847 9 7684244 [T/C] rs12376595 9 7685789 [A/C] rs10117896 9 7687255 [A/G] rs842302 9 7688633 [T/C] rs10283667 9 7688878 [A/G] rs12553528 9 7689040 [T/C] rs1332911 9 7689651 [A/G] rs7046363 9 7690568 [T/C] rs12002314 9 7694465 [A/G] rs842301 9 7694484 [T/C] rs12553833 9 7695593 [T/C] rs328838 9 7703280 [A/C] rs1332905 9 7706762 [T/C] rs170620 9 7707372 [A/G] rs328864 9 7711440 [A/G] rs328863 9 7711546 [T/C] rs4742386 9 7711758 [A/G] rs1905761 9 7712116 [T/C] rs842296 9 7720636 [T/C] rs186629 9 7725346 [A/G] rs328862 9 7725409 [A/C] rs328860 9 7725912 [A/G] rs1332900 9 7726450 [A/G] rs328857 9 7726901 [T/C] rs702283 9 7727062 [A/G] rs842300 9 7727088 [A/G] rs17546550 9 7729573 [A/G] rs7854298 9 7730729 [T/C] rs12344462 9 7734480 [T/C] rs17629093 9 7735283 [T/C] rs1412770 9 7736266 [A/G] rs1332906 9 7742476 [A/G] rs1332924 9 7755443 [A/G] rs7021164 9 7757657 [A/G] rs7863770 9 7757891 [T/C] rs10815672 9 7758579 [A/G] rs11791458 9 7759020 [T/C] rs10119431 9 7759331 [A/G] rs16926737 9 7759917 [T/C] rs1576939 9 7764226 [A/G] rs1576938 9 7764377 [A/G] rs1360585 9 7769626 [T/C] rs9407382 9 7770233 [A/G] rs10758900 9 7770942 [T/G] rs4742408 9 7773723 [A/C] rs7044932 9 7773856 [A/G] rs4742409 9 7774180 [A/C] rs9407384 9 7775651 [A/G] rs7863054 9 7780159 [T/C] rs7035746 9 7780854 [T/G] rs327752 9 7782594 [A/G] rs182753 9 7783210 [T/G] rs3904482 9 7784512 [T/C] rs7035953 9 7787532 [T/C] rs12347887 9 7789577 [A/G] rs6477238 9 7790322 [A/G] rs327756 9 7790940 [T/C] rs4740914 9 7791704 [A/G] rs10815682 9 7792318 [A/C] rs327755 9 7792599 [A/C] rs327754 9 7792930 [T/C] rs327753 9 7793309 [T/C] rs10976578 9 7795050 [A/G] rs10976580 9 7796237 [A/G] rs2990600 9 7796329 [T/G] rs14059 9 7799606 [A/C] NM_001318058,NM_033428,NM_001318059 DMAC1,DMAC1,DMAC1 EXON Synonymous_L43L,Synonymous_L43L,Synonymous_L43L rs2297554 9 7799787 [T/C] NM_001318058,NM_033428,NM_001318059 DMAC1,DMAC1,DMAC1 EXON Silent,Silent,Silent rs9407389 9 7802252 [T/C] rs10123827 9 7804131 [T/C] rs4740916 9 7806697 [T/C] rs12057040 9 7812484 [A/G] rs13297065 9 7813034 [A/G] rs1332916 9 7814465 [A/G] rs1360583 9 7815105 [A/G] rs7849315 9 7815375 [A/G] rs9407390 9 7815985 [T/G] rs10123429 9 7818641 [A/C] rs9407391 9 7819715 [A/G] rs10976603 9 7820080 [A/G] rs1930503 9 7820315 [A/G] rs9408714 9 7820479 [T/G] rs10815687 9 7821493 [T/C] rs2184034 9 7822486 [T/C] rs928459 9 7824326 [T/C] rs9408716 9 7824725 [T/C] rs10976606 9 7826827 [T/C] rs1360582 9 7827205 [T/G] rs9299057 9 7829623 [A/C] rs3847266 9 7833215 [T/C] rs12236892 9 7834442 [T/C] rs10976614 9 7842130 [T/C] rs10976617 9 7842694 [T/C] rs10976618 9 7843141 [T/C] rs12351950 9 7843368 [T/G] rs7042604 9 7852471 [A/G] rs2890765 9 7853855 [A/G] rs7847381 9 7856992 [T/C] rs16926807 9 7857217 [A/C] rs10976635 9 7868691 [T/C] rs10815701 9 7871163 [A/G] rs4595180 9 7871453 [T/C] rs10758911 9 7871717 [A/G] rs10815702 9 7873630 [T/C] rs12156604 9 7874458 [A/G] rs7874427 9 7874526 [A/G] rs10758913 9 7887951 [T/C] rs7028816 9 7889991 [A/G] rs17630650 9 7891408 [T/G] rs10511487 9 7895438 [T/C] rs10758914 9 7897865 [A/G] rs10732363 9 7898810 [A/G] rs10122520 9 7898998 [A/G] rs4302898 9 7901308 [A/G] rs10815705 9 7902402 [T/G] rs10976654 9 7902733 [A/G] rs10815710 9 7906830 [A/G] rs12347060 9 7906933 [A/C] rs10815712 9 7907459 [T/C] rs16926845 9 7908874 [T/C] rs10976659 9 7909429 [A/G] rs7849795 9 7909576 [T/G] rs13297029 9 7910358 [T/G] rs10815713 9 7911344 [T/C] rs10976664 9 7912161 [A/G] rs2890768 9 7913952 [A/G] rs10815714 9 7914008 [T/C] rs1998371 9 7915771 [A/C] rs2224601 9 7918996 [A/G] rs2208742 9 7919153 [T/C] rs7868745 9 7922071 [T/C] rs4740922 9 7924047 [A/C] rs1535480 9 7925381 [T/G] rs11999820 9 7925745 [A/C] rs7863870 9 7928341 [T/G] rs2093483 9 7929372 [A/G] rs875917 9 7930092 [T/C] rs16926885 9 7930520 [A/G] rs10976676 9 7932619 [A/G] rs10976678 9 7935323 [T/C] rs10815718 9 7935389 [T/C] rs2065113 9 7938226 [A/G] rs10758915 9 7938795 [T/G] rs10815721 9 7945146 [A/G] rs7868963 9 7947001 [A/G] rs1322468 9 7949546 [A/C] rs10815723 9 7951024 [T/C] rs10815725 9 7951684 [A/C] rs4742424 9 7955178 [A/C] rs10976692 9 7962765 [A/G] rs2065119 9 7966280 [A/G] rs1407467 9 7968906 [T/G] rs10514819 9 7978514 [T/C] rs2025192 9 7979082 [T/C] rs10976702 9 7979694 [A/G] rs1322473 9 7979832 [T/C] rs7875477 9 7980064 [A/G] rs7871884 9 7983044 [A/G] rs1407469 9 7985651 [A/G] rs1322474 9 7987272 [T/G] rs1322475 9 7988643 [A/G] rs11999299 9 7993836 [T/C] rs764310 9 7994225 [A/G] rs764308 9 7994349 [A/G] rs10976710 9 7994891 [T/C] rs2025193 9 7995103 [T/C] rs12348891 9 7999201 [A/C] rs12348939 9 7999346 [A/G] rs9408721 9 8009428 [A/G] rs12337889 9 8009807 [T/C] rs7030273 9 8010899 [T/C] rs4740924 9 8011107 [A/G] rs10758920 9 8011265 [A/G] rs12685956 9 8012608 [T/C] rs10976719 9 8012773 [A/G] rs9299059 9 8014674 [T/C] rs1322458 9 8021344 [T/C] rs1407461 9 8023123 [T/G] rs7849676 9 8025789 [A/G] rs7024333 9 8029327 [A/G] rs7027896 9 8029507 [T/C] rs10976737 9 8040076 [T/G] rs2146180 9 8045606 [A/G] rs1575326 9 8058763 [A/C] rs7357637 9 8059266 [A/G] rs1322467 9 8063984 [A/G] rs6477256 9 8065584 [A/G] rs10976748 9 8073094 [T/C] rs10815746 9 8074897 [A/G] rs2381700 9 8075119 [T/C] rs16927027 9 8075139 [A/G] rs7846713 9 8079286 [T/C] rs10976758 9 8087483 [T/C] rs975299 9 8087860 [T/G] rs4742447 9 8089306 [A/G] rs7020343 9 8090327 [T/C] rs7020466 9 8090430 [T/C] rs10976762 9 8092506 [A/G] rs10976763 9 8093826 [T/C] rs10815753 9 8093954 [A/G] rs11999343 9 8094390 [T/G] rs6477258 9 8095638 [T/C] rs10815757 9 8097977 [T/C] rs10815759 9 8102543 [T/G] rs7862526 9 8106282 [T/G] rs10976775 9 8108652 [T/C] rs9650711 9 8108790 [A/G] rs10121636 9 8110767 [T/C] rs10758936 9 8114588 [A/G] rs989726 9 8115492 [A/G] rs12336338 9 8116662 [A/C] rs10976780 9 8117656 [T/C] rs7048333 9 8119459 [T/C] rs16927126 9 8120905 [T/C] rs7034109 9 8121487 [T/C] rs10976786 9 8121725 [A/C] rs16927134 9 8123423 [T/G] rs10441691 9 8125336 [A/G] rs10758939 9 8125410 [A/G] rs1578118 9 8131068 [A/G] rs7855517 9 8132822 [A/G] rs1361317 9 8133055 [T/G] rs911763 9 8133859 [T/G] rs941904 9 8136132 [T/C] rs16927158 9 8138580 [A/G] rs964222 9 8139013 [A/G] rs12238899 9 8141003 [T/C] rs7875279 9 8142392 [T/C] rs7466234 9 8143737 [A/G] rs10976799 9 8144973 [A/G] rs10976802 9 8147857 [A/G] rs1361315 9 8156271 [T/G] rs9696734 9 8157022 [T/C] rs10815774 9 8157313 [A/G] rs13287364 9 8160714 [A/G] rs10976812 9 8161572 [A/G] rs4742463 9 8161748 [T/C] rs17631170 9 8165056 [A/G] rs12555677 9 8165192 [T/C] rs13299501 9 8165446 [T/G] rs11794801 9 8169035 [T/C] rs10976815 9 8169707 [A/C] rs13292463 9 8170945 [A/G] rs10739149 9 8171386 [T/C] rs12237835 9 8172046 [A/C] rs7049111 9 8172988 [T/C] rs12336957 9 8173378 [A/C] rs1538518 9 8174284 [A/G] rs10733542 9 8175757 [A/C] rs10739150 9 8176226 [T/G] rs10733543 9 8176622 [T/C] rs12347722 9 8178632 [A/G] rs4130580 9 8179325 [T/C] rs10976822 9 8180646 [T/C] rs10976823 9 8180709 [T/G] rs10976826 9 8181494 [A/G] rs10739153 9 8181848 [T/C] rs12003225 9 8182214 [A/G] rs10976830 9 8184461 [A/G] rs10976831 9 8185170 [A/C] rs7860133 9 8188463 [A/G] rs10976839 9 8193646 [A/G] rs7044355 9 8196511 [A/G] rs1781276 9 8206576 [T/C] rs1538523 9 8206769 [A/G] rs2185233 9 8208014 [A/G] rs7869678 9 8208407 [A/G] rs9299064 9 8208999 [T/C] rs10815790 9 8209809 [T/C] rs4008257 9 8213656 [A/C] rs10815791 9 8215609 [T/C] rs3847274 9 8219852 [A/G] rs4127335 9 8220067 [T/G] rs4742469 9 8221247 [A/G] rs7867627 9 8223541 [A/G] rs10976860 9 8227101 [T/C] rs10815796 9 8227693 [A/G] rs13287379 9 8229283 [A/G] rs1781263 9 8230268 [A/G] rs1984216 9 8230433 [A/G] rs12238157 9 8231452 [A/G] rs7038843 9 8231940 [A/G] rs1339287 9 8233804 [T/C] rs1768574 9 8234235 [A/G] rs1768575 9 8235513 [A/G] rs10815798 9 8235633 [A/G] rs6477284 9 8235673 [T/C] rs9407406 9 8239748 [T/G] rs10976869 9 8241238 [A/G] rs17550688 9 8241736 [A/C] rs7043322 9 8241845 [T/C] rs12238640 9 8241971 [A/G] rs3842929 9 8242654 [A/G] rs3847275 9 8243576 [T/C] rs1416592 9 8247628 [T/C] rs1344183 9 8253019 [T/C] rs7861890 9 8255046 [A/G] rs10733544 9 8255691 [A/G] rs10815803 9 8257725 [A/G] rs10815806 9 8258063 [A/G] rs7048696 9 8258921 [A/G] rs10976889 9 8260565 [T/C] rs10815807 9 8260602 [T/C] rs884540 9 8260902 [A/G] rs3858055 9 8261021 [A/C] rs3847279 9 8261551 [A/G] rs3847280 9 8261820 [A/G] rs3847281 9 8261910 [A/G] rs7045605 9 8262469 [T/G] rs10976896 9 8264662 [A/G] rs12346800 9 8265726 [A/C] rs1027582 9 8267854 [A/G] rs10976907 9 8268343 [A/C] rs7025712 9 8269073 [T/C] rs3847282 9 8269791 [A/G] rs12005381 9 8270002 [A/G] rs10815816 9 8270830 [T/G] rs7864066 9 8277169 [T/G] rs1500304 9 8279622 [T/G] rs12340115 9 8281308 [A/G] rs12343846 9 8283676 [T/C] rs1472535 9 8284560 [A/G] rs7872172 9 8284965 [T/G] rs7862136 9 8285325 [A/G] rs1500309 9 8296344 [A/C] rs970347 9 8299968 [A/G] rs10976929 9 8301561 [A/G] rs12336333 9 8302687 [T/G] rs10976939 9 8310575 [T/C] rs1155271 9 8312169 [T/C] rs10114301 9 8312318 [T/G] rs7867924 9 8318851 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1353983 9 8318948 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7873084 9 8319806 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7848626 9 8322288 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10976958 9 8329288 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10739155 9 8330652 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs16927547 9 8332307 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7032880 9 8337939 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs3780336 9 8338690 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs3847286 9 8338878 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815825 9 8344187 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10511491 9 8345923 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7848705 9 8346265 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815828 9 8348602 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7864233 9 8355415 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1818072 9 8360320 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977002 9 8366920 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1500321 9 8367795 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12554953 9 8368253 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977007 9 8368980 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1500323 9 8370763 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs4742488 9 8371405 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977013 9 8373105 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7038767 9 8373735 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12342923 9 8375333 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1039336 9 8376287 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs2291958 9 8376899 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1392521 9 8379313 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1500325 9 8379838 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7031533 9 8381851 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12375761 9 8382718 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1875238 9 8382720 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1500326 9 8382966 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977022 9 8385838 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs989813 9 8385969 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977023 9 8388220 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1500327 9 8390467 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1500328 9 8390505 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977035 9 8393528 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7851088 9 8395367 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1021719 9 8395913 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1909756 9 8396388 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1500334 9 8396543 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10116650 9 8397775 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10124689 9 8399766 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815854 9 8401031 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7876037 9 8403640 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7042145 9 8404095 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs3739577 9 8404987 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977054 9 8405543 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1500336 9 8406003 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815855 9 8408453 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12156512 9 8408724 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs3903826 9 8408803 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977059 9 8409329 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7856797 9 8411848 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10511494 9 8416196 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977081 9 8423755 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815867 9 8428249 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12348387 9 8428332 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815868 9 8428492 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs9792404 9 8429048 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs4742502 9 8430033 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs942176 9 8430742 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs2381798 9 8431163 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7866424 9 8432073 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs16927848 9 8432349 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7040015 9 8432653 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977093 9 8432782 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7027844 9 8433160 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7047641 9 8433698 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs2381800 9 8435110 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs2890794 9 8435525 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815873 9 8436194 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977103 9 8436963 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977109 9 8441203 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815875 9 8441646 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815876 9 8445288 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7855100 9 8445864 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs2890795 9 8447732 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1323587 9 8448426 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs16927892 9 8448775 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815877 9 8450441 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815878 9 8451191 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977117 9 8451755 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12375674 9 8452953 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1323588 9 8453781 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7031287 9 8454566 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7870456 9 8454921 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs6477310 9 8456247 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10122691 9 8458811 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs2296097 9 8460178 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs2281747 9 8465598 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD EXON Synonymous_A783A,Synonymous_A1194A,Synonymous_A780A,Synonymous_A783A,Synonymous_A773A,Synonymous_A778A rs13301764 9 8467855 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12340424 9 8468567 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977131 9 8469173 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7862199 9 8470572 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1359120 9 8470974 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12346891 9 8471712 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs13283150 9 8473337 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977144 9 8474233 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12340876 9 8476994 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs2381804 9 8478068 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815884 9 8480144 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815885 9 8480428 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs13294270 9 8480519 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10117986 9 8482408 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs16928002 9 8484039 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12344148 9 8484240 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD EXON Synonymous_R687R,Synonymous_R1098R,Synonymous_R684R,Synonymous_R687R,Synonymous_R677R,Synonymous_R682R rs3824417 9 8485928 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD EXON Silent,Synonymous_I963I,Silent,Silent,Silent,Silent rs2296101 9 8489006 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10120463 9 8490886 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7858815 9 8494221 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7025468 9 8495756 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10124277 9 8499295 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7035558 9 8500472 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs6477312 9 8501698 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs13296910 9 8502071 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7868790 9 8505087 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1998516 9 8508148 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1535678 9 8509378 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs16928072 9 8509880 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1998517 9 8512133 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1323578 9 8513123 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10124872 9 8515987 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815897 9 8517383 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10120190 9 8517545 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7026388 9 8518143 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD EXON Synonymous_A416A,Synonymous_A416A,Synonymous_A413A,Synonymous_A416A,Synonymous_A406A,Synonymous_A410A rs3763653 9 8518395 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD EXON Synonymous_T332T,Synonymous_T332T,Synonymous_T329T,Synonymous_T332T,Synonymous_T322T,Synonymous_T326T rs7039690 9 8520287 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10511499 9 8521121 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs6477314 9 8522326 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977176 9 8524448 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs2273998 9 8524854 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10758982 9 8533412 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7046918 9 8534385 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs2184978 9 8538919 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7856850 9 8546095 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7864527 9 8553569 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10217447 9 8554938 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7026937 9 8558331 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs13294631 9 8562080 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12235202 9 8565148 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977207 9 8569186 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1337811 9 8574577 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977210 9 8578261 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12683419 9 8580675 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12340105 9 8582187 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977213 9 8582229 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs13293506 9 8584312 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7861140 9 8585188 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs2184979 9 8590341 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7020239 9 8595338 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs9792470 9 8598737 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs9792461 9 8603606 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7853846 9 8608068 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs16928196 9 8608349 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977230 9 8610513 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1361117 9 8615045 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs16928221 9 8619879 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10758985 9 8620382 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1512381 9 8635810 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs16928234 9 8645448 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7041298 9 8649429 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1028018 9 8659757 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1025547 9 8664838 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12683865 9 8669129 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10815923 9 8669273 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7859849 9 8670737 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977243 9 8672042 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs16924692 9 8672923 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs16928255 9 8678991 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10511506 9 8682672 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7021243 9 8692722 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1434264 9 8693517 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10125358 9 8694330 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs16928280 9 8695233 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs12685924 9 8695439 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1368981 9 8696227 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs4442186 9 8700193 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10481623 9 8700396 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10758987 9 8702964 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1543083 9 8703025 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1550002 9 8704192 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7867247 9 8705964 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs4742531 9 8706540 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs17653604 9 8710180 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10758988 9 8712365 [A/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1821429 9 8715082 [A/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs17575409 9 8718703 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs7866922 9 8719261 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977260 9 8720393 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs10977261 9 8722635 [T/G] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1473822 9 8726153 [T/C] NM_130391,NM_002839,NM_001040712,NM_130392,NM_001171025,NM_130393 PTPRD,PTPRD,PTPRD,PTPRD,PTPRD,PTPRD Silent,Silent,Silent,Silent,Silent,Silent rs1434250 9 8736813 [T/G] NM_002839 PTPRD Silent rs6477333 9 8737316 [A/G] NM_002839 PTPRD Silent rs4742533 9 8738267 [T/C] NM_002839 PTPRD Silent rs10465099 9 8739061 [T/C] NM_002839 PTPRD Silent rs2033554 9 8741389 [T/G] NM_002839 PTPRD Silent rs10977272 9 8743598 [T/G] NM_002839 PTPRD Silent rs7038493 9 8745520 [A/G] NM_002839 PTPRD Silent rs7869843 9 8746568 [A/G] NM_002839 PTPRD Silent rs7039134 9 8749552 [A/G] NM_002839 PTPRD Silent rs12338284 9 8751968 [A/G] NM_002839 PTPRD Silent rs7873178 9 8752743 [A/G] NM_002839 PTPRD Silent rs10733548 9 8754549 [T/C] NM_002839 PTPRD Silent rs10117781 9 8757828 [A/C] NM_002839 PTPRD Silent rs10117784 9 8757841 [T/C] NM_002839 PTPRD Silent rs7021320 9 8771874 [A/C] NM_002839 PTPRD Silent rs1036327 9 8774025 [T/C] NM_002839 PTPRD Silent rs1036331 9 8774381 [T/G] NM_002839 PTPRD Silent rs9299072 9 8777779 [T/G] NM_002839 PTPRD Silent rs10977298 9 8778606 [T/C] NM_002839 PTPRD Silent rs16928439 9 8780293 [T/C] NM_002839 PTPRD Silent rs10977299 9 8784855 [T/C] NM_002839 PTPRD Silent rs13440123 9 8785993 [A/G] NM_002839 PTPRD Silent rs13283979 9 8786827 [A/G] NM_002839 PTPRD Silent rs3802396 9 8787733 [T/C] NM_002839 PTPRD Silent rs7862354 9 8791925 [T/C] NM_002839 PTPRD Silent rs12348514 9 8791981 [T/G] NM_002839 PTPRD Silent rs2082633 9 8794314 [A/G] NM_002839 PTPRD Silent rs765800 9 8794775 [A/G] NM_002839 PTPRD Silent rs7032107 9 8795072 [A/C] NM_002839 PTPRD Silent rs1550004 9 8796449 [T/C] NM_002839 PTPRD Silent rs9299075 9 8798347 [A/G] NM_002839 PTPRD Silent rs10123595 9 8799819 [T/C] NM_002839 PTPRD Silent rs4562389 9 8805462 [T/C] NM_002839 PTPRD Silent rs6477355 9 8809042 [A/G] NM_002839 PTPRD Silent rs10733549 9 8812415 [T/C] NM_002839 PTPRD Silent rs7855709 9 8812871 [T/C] NM_002839 PTPRD Silent rs10815954 9 8813497 [T/G] NM_002839 PTPRD Silent rs10815957 9 8815247 [T/C] NM_002839 PTPRD Silent rs10815959 9 8816479 [A/G] NM_002839 PTPRD Silent rs1434273 9 8817060 [T/C] NM_002839 PTPRD Silent rs1434274 9 8817244 [T/C] NM_002839 PTPRD Silent rs10815964 9 8826108 [A/G] NM_002839 PTPRD Silent rs7863174 9 8827680 [A/G] NM_002839 PTPRD Silent rs10815966 9 8828693 [A/G] NM_002839 PTPRD Silent rs10977313 9 8828849 [T/G] NM_002839 PTPRD Silent rs10815967 9 8829390 [A/C] NM_002839 PTPRD Silent rs10758997 9 8829567 [T/C] NM_002839 PTPRD Silent rs1434256 9 8830796 [T/C] NM_002839 PTPRD Silent rs7030557 9 8831995 [A/G] NM_002839 PTPRD Silent rs11791648 9 8832025 [A/G] NM_002839 PTPRD Silent rs7048621 9 8832038 [T/C] NM_002839 PTPRD Silent rs2570299 9 8840840 [A/G] NM_002839 PTPRD Silent rs2570961 9 8845429 [A/G] NM_002839 PTPRD Silent rs1865343 9 8845598 [A/G] NM_002839 PTPRD Silent rs1865341 9 8845911 [T/C] NM_002839 PTPRD Silent rs2570960 9 8846052 [A/G] NM_002839 PTPRD Silent rs1975197 9 8846955 [A/G] NM_002839 PTPRD Silent rs2117100 9 8847013 [T/C] NM_002839 PTPRD Silent rs2117099 9 8847233 [A/G] NM_002839 PTPRD Silent rs4742544 9 8848290 [T/C] NM_002839 PTPRD Silent rs10123580 9 8850237 [T/C] NM_002839 PTPRD Silent rs10759003 9 8851012 [A/G] NM_002839 PTPRD Silent rs2570301 9 8852226 [A/G] NM_002839 PTPRD Silent rs10977321 9 8852668 [T/C] NM_002839 PTPRD Silent rs3891649 9 8853690 [T/C] NM_002839 PTPRD Silent rs7466280 9 8854069 [A/G] NM_002839 PTPRD Silent rs10759006 9 8855603 [T/C] NM_002839 PTPRD Silent rs751372 9 8856908 [T/C] NM_002839 PTPRD Silent rs13284801 9 8857079 [T/G] NM_002839 PTPRD Silent rs10815977 9 8860355 [A/G] NM_002839,NR_121600,NR_121599 PTPRD,PTPRD-AS1,PTPRD-AS1 Silent,Silent,Silent rs10977327 9 8865925 [A/G] NM_002839 PTPRD Silent rs723145 9 8867519 [A/G] NM_002839 PTPRD Silent rs2217711 9 8868177 [T/C] NM_002839 PTPRD Silent rs10815979 9 8868774 [T/C] NM_002839 PTPRD Silent rs12002381 9 8870553 [T/C] NM_002839 PTPRD Silent rs10759008 9 8873348 [A/G] NM_002839 PTPRD Silent rs10759009 9 8873449 [A/G] NM_002839 PTPRD Silent rs10977332 9 8875659 [A/G] NM_002839 PTPRD Silent rs10759013 9 8875954 [A/C] NM_002839 PTPRD Silent rs12000930 9 8877814 [T/C] NM_002839 PTPRD Silent rs17584499 9 8879118 [T/C] NM_002839 PTPRD Silent rs7023424 9 8879472 [A/G] NM_002839 PTPRD Silent rs10815983 9 8881741 [A/G] NM_002839 PTPRD Silent rs13287579 9 8884015 [A/G] NM_002839 PTPRD Silent rs10815984 9 8884844 [T/C] NM_002839 PTPRD Silent rs10815986 9 8885169 [A/G] NM_002839 PTPRD Silent rs10759014 9 8885476 [A/G] NM_002839 PTPRD Silent rs10511512 9 8889419 [A/C] NM_002839 PTPRD Silent rs2890841 9 8890725 [T/C] NM_002839 PTPRD Silent rs7867067 9 8890946 [A/G] NM_002839 PTPRD Silent rs10815989 9 8891463 [A/G] NM_002839 PTPRD Silent rs7850165 9 8893834 [A/G] NM_002839 PTPRD Silent rs7853293 9 8894013 [A/G] NM_002839 PTPRD Silent rs10977337 9 8894070 [T/C] NM_002839 PTPRD Silent rs2196066 9 8894910 [A/C] NM_002839 PTPRD Silent rs1368680 9 8895687 [T/C] NM_002839 PTPRD Silent rs7866753 9 8897215 [T/C] NM_002839 PTPRD Silent rs6477360 9 8897230 [T/C] NM_002839 PTPRD Silent rs11794550 9 8897676 [A/G] NM_002839 PTPRD Silent rs10511511 9 8900067 [T/C] NM_002839 PTPRD Silent rs7856948 9 8900641 [A/G] NM_002839 PTPRD Silent rs17585256 9 8901157 [T/G] NM_002839 PTPRD Silent rs12554855 9 8901169 [A/C] NM_002839 PTPRD Silent rs1433540 9 8901682 [T/G] NM_002839 PTPRD Silent rs10759016 9 8906136 [T/C] NM_002839 PTPRD Silent rs10815996 9 8915142 [T/C] NM_002839 PTPRD Silent rs10046838 9 8916449 [A/G] NM_002839 PTPRD Silent rs16928621 9 8921426 [A/C] NM_002839 PTPRD Silent rs4740969 9 8922286 [A/G] NM_002839 PTPRD Silent rs10977362 9 8922467 [A/G] NM_002839 PTPRD Silent rs7858751 9 8923010 [T/C] NM_002839 PTPRD Silent rs7858252 9 8923351 [A/G] NM_002839 PTPRD Silent rs16928627 9 8923381 [T/C] NM_002839 PTPRD Silent rs7020371 9 8923715 [T/C] NM_002839 PTPRD Silent rs1368684 9 8924538 [T/C] NM_002839 PTPRD Silent rs9644893 9 8925157 [A/C] NM_002839 PTPRD Silent rs10977363 9 8926071 [A/C] NM_002839 PTPRD Silent rs1897676 9 8926956 [T/C] NM_002839 PTPRD Silent rs10759020 9 8936967 [T/G] NM_002839 PTPRD Silent rs1433548 9 8937116 [T/C] NM_002839 PTPRD Silent rs10511514 9 8937478 [T/C] NM_002839 PTPRD Silent rs1368687 9 8939271 [T/C] NM_002839 PTPRD Silent rs7047447 9 8940141 [T/C] NM_002839 PTPRD Silent rs12344877 9 8941521 [T/C] NM_002839 PTPRD Silent rs10759021 9 8941696 [A/G] NM_002839 PTPRD Silent rs9696786 9 8950179 [T/C] NM_002839 PTPRD Silent rs10816018 9 8951749 [T/C] NM_002839 PTPRD Silent rs7848109 9 8953425 [T/G] NM_002839 PTPRD Silent rs7852703 9 8955010 [A/C] NM_002839 PTPRD Silent rs10977400 9 8955509 [A/G] NM_002839 PTPRD Silent rs4526401 9 8956534 [T/C] NM_002839 PTPRD Silent rs7037483 9 8960011 [A/G] NM_002839 PTPRD Silent rs7851829 9 8960329 [A/G] NM_002839 PTPRD Silent rs1433552 9 8967563 [T/C] NM_002839 PTPRD Silent rs10816022 9 8970493 [T/C] NM_002839 PTPRD Silent rs13289308 9 8971666 [T/C] NM_002839 PTPRD Silent rs7022702 9 8976241 [A/G] NM_002839 PTPRD Silent rs17586734 9 8977444 [A/G] NM_002839 PTPRD Silent rs12554851 9 8980881 [T/C] NM_002839 PTPRD Silent rs1036278 9 8981644 [A/C] NM_002839 PTPRD Silent rs10511516 9 8982308 [A/G] NM_002839 PTPRD Silent rs10816027 9 8982620 [A/C] NM_002839 PTPRD Silent rs4742554 9 8984469 [T/G] NM_002839 PTPRD Silent rs10977424 9 8985404 [A/G] NM_002839 PTPRD Silent rs9299083 9 8987930 [T/C] NM_002839 PTPRD Silent rs2039331 9 8988375 [T/C] NM_002839 PTPRD Silent rs9299084 9 8993027 [T/C] NM_002839 PTPRD Silent rs1331665 9 8996113 [T/G] NM_002839 PTPRD Silent rs10977429 9 8996408 [T/C] NM_002839 PTPRD Silent rs10977432 9 8999697 [T/C] NM_002839 PTPRD Silent rs973117 9 9000033 [A/C] NM_002839 PTPRD Silent rs7871755 9 9000709 [A/C] NM_002839 PTPRD Silent rs10511519 9 9001207 [T/C] NM_002839 PTPRD Silent rs10816028 9 9001239 [T/C] NM_002839 PTPRD Silent rs10511520 9 9001538 [T/C] NM_002839 PTPRD Silent rs12006331 9 9003758 [T/G] NM_002839 PTPRD Silent rs17587560 9 9004122 [A/G] NM_002839 PTPRD Silent rs1331662 9 9010662 [T/C] NM_002839 PTPRD Silent rs7046257 9 9011209 [A/G] NM_002839 PTPRD Silent rs613613 9 9014274 [T/C] NM_002839 PTPRD Silent rs440238 9 9016071 [A/C] NM_002839 PTPRD Silent rs420441 9 9017136 [T/C] NM_002839 PTPRD Silent rs17587734 9 9018296 [A/G] NM_002839 PTPRD Silent rs7029807 9 9018656 [T/G] NM_002839 PTPRD Silent rs378363 9 9020223 [T/C] NM_002839 PTPRD Silent rs1041506 9 9022772 [A/G] NM_002839 PTPRD Silent rs324494 9 9023450 [T/G] NM_002839 PTPRD Silent rs7875273 9 9023522 [T/C] NM_002839 PTPRD Silent rs324493 9 9024060 [A/G] NM_002839 PTPRD Silent rs540259 9 9026157 [T/C] NM_002839 PTPRD Silent rs167785 9 9026854 [T/C] NM_002839 PTPRD Silent rs1348641 9 9027495 [T/C] NM_002839 PTPRD Silent rs324495 9 9029463 [A/G] NM_002839 PTPRD Silent rs226361 9 9029847 [A/G] NM_002839 PTPRD Silent rs368381 9 9030732 [A/G] NM_002839 PTPRD Silent rs10120940 9 9030773 [A/C] NM_002839 PTPRD Silent rs382364 9 9031563 [T/C] NM_002839 PTPRD Silent rs1889817 9 9031977 [A/G] NM_002839 PTPRD Silent rs182719 9 9032105 [A/G] NM_002839 PTPRD Silent rs895173 9 9032560 [T/C] NM_002839 PTPRD Silent rs172862 9 9032872 [T/C] NM_002839 PTPRD Silent rs1999740 9 9033824 [A/G] NM_002839 PTPRD Silent rs324517 9 9037625 [T/G] NM_002839 PTPRD Silent rs324519 9 9038430 [T/C] NM_002839 PTPRD Silent rs1331660 9 9039222 [A/G] NM_002839 PTPRD Silent rs324524 9 9040946 [A/G] NM_002839 PTPRD Silent rs10739183 9 9041579 [T/C] NM_002839 PTPRD Silent rs324526 9 9042075 [T/C] NM_002839 PTPRD Silent rs324527 9 9042311 [T/C] NM_002839 PTPRD Silent rs7034007 9 9042383 [A/G] NM_002839 PTPRD Silent rs324529 9 9042840 [A/G] NM_002839 PTPRD Silent rs88818 9 9043421 [T/G] NM_002839 PTPRD Silent rs324533 9 9045011 [A/G] NM_002839 PTPRD Silent rs1118100 9 9047488 [T/C] NM_002839 PTPRD Silent rs13285004 9 9048128 [T/C] NM_002839 PTPRD Silent rs7035296 9 9049813 [A/C] NM_002839 PTPRD Silent rs10759035 9 9052619 [A/G] NM_002839 PTPRD Silent rs12685303 9 9052964 [A/G] NM_002839 PTPRD Silent rs12005189 9 9054075 [T/C] NM_002839 PTPRD Silent rs2225482 9 9054313 [T/C] NM_002839 PTPRD Silent rs1412096 9 9054913 [A/C] NM_002839 PTPRD Silent rs10977457 9 9055544 [A/G] NM_002839 PTPRD Silent rs10816040 9 9057632 [A/G] NM_002839 PTPRD Silent rs17665194 9 9059182 [T/C] NM_002839 PTPRD Silent rs324498 9 9059545 [A/G] NM_002839 PTPRD Silent rs12555043 9 9060444 [A/G] NM_002839 PTPRD Silent rs12006155 9 9061331 [T/C] NM_002839 PTPRD Silent rs324501 9 9061819 [A/G] NM_002839 PTPRD Silent rs10977464 9 9064311 [T/C] NM_002839 PTPRD Silent rs10759037 9 9064330 [T/C] NM_002839 PTPRD Silent rs7026475 9 9065478 [A/G] NM_002839 PTPRD Silent rs16928863 9 9065718 [A/G] NM_002839 PTPRD Silent rs324506 9 9066755 [A/G] NM_002839 PTPRD Silent rs408960 9 9069839 [T/C] NM_002839 PTPRD Silent rs324513 9 9070768 [A/G] NM_002839 PTPRD Silent rs12339518 9 9071242 [A/G] NM_002839 PTPRD Silent rs634921 9 9072276 [A/C] NM_002839 PTPRD Silent rs324482 9 9073241 [T/C] NM_002839 PTPRD Silent rs324484 9 9074042 [A/G] NM_002839 PTPRD Silent rs324486 9 9074830 [A/G] NM_002839 PTPRD Silent rs324475 9 9077607 [T/G] NM_002839 PTPRD Silent rs324479 9 9079771 [A/G] NM_002839 PTPRD Silent rs324480 9 9079956 [T/C] NM_002839 PTPRD Silent rs369166 9 9086923 [A/G] NM_002839 PTPRD Silent rs10977480 9 9092671 [A/G] NM_002839 PTPRD Silent rs10977482 9 9093111 [A/G] NM_002839 PTPRD Silent rs472324 9 9094805 [A/G] NM_002839 PTPRD Silent rs324542 9 9102409 [T/C] NM_002839 PTPRD Silent rs10977497 9 9104869 [A/G] NM_002839 PTPRD Silent rs324544 9 9108336 [T/C] NM_002839 PTPRD Silent rs9299087 9 9109538 [T/C] NM_002839 PTPRD Silent rs10816047 9 9109843 [A/G] NM_002839 PTPRD Silent rs17589981 9 9119229 [T/C] NM_002839 PTPRD Silent rs324540 9 9119349 [T/C] NM_002839 PTPRD Silent rs10120781 9 9125205 [T/C] NM_002839 PTPRD Silent rs10115009 9 9128478 [T/C] NM_002839 PTPRD Silent rs10124317 9 9130204 [T/G] NM_002839 PTPRD Silent rs10511521 9 9133196 [T/C] NM_002839 PTPRD Silent rs9299088 9 9139360 [A/G] NM_002839 PTPRD Silent rs957155 9 9142828 [T/C] NM_002839 PTPRD Silent rs10816049 9 9144085 [T/C] NM_002839 PTPRD Silent rs1992672 9 9145908 [T/C] NM_002839 PTPRD Silent rs10121402 9 9146300 [T/C] NM_002839 PTPRD Silent rs1999741 9 9149128 [T/C] NM_002839 PTPRD Silent rs10977530 9 9149546 [A/G] NM_002839 PTPRD Silent rs2381968 9 9150790 [T/G] NM_002839 PTPRD Silent rs7861959 9 9151280 [A/G] NM_002839 PTPRD Silent rs12003392 9 9151640 [T/C] NM_002839 PTPRD Silent rs7854497 9 9153346 [A/G] NM_002839 PTPRD Silent rs6477369 9 9155409 [T/C] NM_002839 PTPRD Silent rs7036801 9 9155721 [T/C] NM_002839 PTPRD Silent rs7040160 9 9156055 [T/C] NM_002839 PTPRD Silent rs12375909 9 9158221 [T/C] NM_002839 PTPRD Silent rs12003567 9 9161679 [T/C] NM_002839 PTPRD Silent rs2890854 9 9161898 [T/C] NM_002839 PTPRD Silent rs10816054 9 9162042 [T/C] NM_002839 PTPRD Silent rs1445206 9 9164473 [A/G] NM_002839 PTPRD Silent rs16929002 9 9166711 [A/G] NM_002839 PTPRD Silent rs10977545 9 9169458 [A/C] NM_002839 PTPRD Silent rs968079 9 9173304 [A/G] NM_002839 PTPRD Silent rs1968589 9 9177013 [T/C] NM_002839 PTPRD Silent rs1348644 9 9178137 [A/G] NM_002839 PTPRD Silent rs2381970 9 9180827 [T/C] NM_002839 PTPRD Silent rs1889820 9 9181361 [T/G] NM_002839 PTPRD Silent rs1445213 9 9182216 [A/G] NM_002839 PTPRD Silent rs1445212 9 9183618 [T/C] NM_002839 PTPRD Silent rs10816060 9 9184911 [T/C] NM_002839 PTPRD Silent rs945464 9 9186346 [T/C] NM_002839 PTPRD Silent rs10977555 9 9187539 [A/G] NM_002839 PTPRD Silent rs1959404 9 9188865 [A/G] NM_002839 PTPRD Silent rs12000334 9 9195240 [T/C] NM_002839 PTPRD Silent rs2028779 9 9195415 [A/C] NM_002839 PTPRD Silent rs2028780 9 9195670 [T/C] NM_002839 PTPRD Silent rs10977564 9 9196661 [A/G] NM_002839 PTPRD Silent rs13440065 9 9197160 [T/C] NM_002839 PTPRD Silent rs10435819 9 9197298 [A/G] NM_002839 PTPRD Silent rs1157067 9 9197812 [T/G] NM_002839 PTPRD Silent rs9987697 9 9202754 [T/G] NM_002839 PTPRD Silent rs10977567 9 9202872 [T/C] NM_002839 PTPRD Silent rs1982319 9 9204531 [T/C] NM_002839 PTPRD Silent rs13283501 9 9211973 [T/G] NM_002839 PTPRD Silent rs4596705 9 9214833 [T/G] NM_002839 PTPRD Silent rs13299658 9 9215776 [A/G] NM_002839 PTPRD Silent rs7034934 9 9216473 [A/G] NM_002839 PTPRD Silent rs4620334 9 9221800 [A/G] NM_002839 PTPRD Silent rs13294494 9 9222258 [T/C] NM_002839 PTPRD Silent rs4357351 9 9223809 [T/C] NM_002839 PTPRD Silent rs7035832 9 9225919 [T/C] NM_002839 PTPRD Silent rs4621866 9 9228094 [T/C] NM_002839 PTPRD Silent rs12336488 9 9228107 [T/C] NM_002839 PTPRD Silent rs17667884 9 9229566 [T/C] NM_002839 PTPRD Silent rs7018892 9 9230415 [A/G] NM_002839 PTPRD Silent rs6477375 9 9230674 [A/G] NM_002839 PTPRD Silent rs10977596 9 9231566 [T/G] NM_002839 PTPRD Silent rs4742569 9 9235200 [T/C] NM_002839 PTPRD Silent rs4742571 9 9235372 [A/C] NM_002839 PTPRD Silent rs4742578 9 9238929 [A/C] NM_002839 PTPRD Silent rs10816071 9 9241520 [A/C] NM_002839 PTPRD Silent rs4568657 9 9246647 [T/C] NM_002839 PTPRD Silent rs10977614 9 9247105 [A/C] NM_002839 PTPRD Silent rs11791447 9 9249795 [T/C] NM_002839 PTPRD Silent rs7032620 9 9249912 [T/C] NM_002839 PTPRD Silent rs6477382 9 9252865 [A/G] NM_002839 PTPRD Silent rs4560852 9 9258729 [T/C] NM_002839 PTPRD Silent rs6477383 9 9258963 [A/G] NM_002839 PTPRD Silent rs17605087 9 9260044 [T/C] NM_002839 PTPRD Silent rs4626664 9 9261737 [A/G] NM_002839 PTPRD Silent rs11792302 9 9261826 [T/C] NM_002839 PTPRD Silent rs4626665 9 9262323 [A/G] NM_002839 PTPRD Silent rs7863177 9 9263980 [T/C] NM_002839 PTPRD Silent rs10816077 9 9264439 [T/G] NM_002839 PTPRD Silent rs9299090 9 9264932 [T/C] NM_002839 PTPRD Silent rs4363255 9 9269284 [T/C] NM_002839 PTPRD Silent rs10816081 9 9270436 [A/G] NM_002839 PTPRD Silent rs4289870 9 9271454 [A/G] NM_002839 PTPRD Silent rs16929125 9 9272114 [A/G] NM_002839 PTPRD Silent rs4302899 9 9272841 [A/G] NM_002839 PTPRD Silent rs10977627 9 9273681 [T/C] NM_002839 PTPRD Silent rs4563945 9 9277320 [A/G] NM_002839 PTPRD Silent rs4492438 9 9282982 [A/G] NM_002839 PTPRD Silent rs10122609 9 9283557 [T/C] NM_002839 PTPRD Silent rs4146134 9 9287321 [T/C] NM_002839 PTPRD Silent rs4146135 9 9287406 [A/G] NM_002839 PTPRD Silent rs12350625 9 9290343 [T/G] NM_002839 PTPRD Silent rs10977642 9 9292356 [T/G] NM_002839 PTPRD Silent rs11795233 9 9292430 [T/G] NM_002839 PTPRD Silent rs1412886 9 9294332 [T/C] NM_002839 PTPRD Silent rs2151324 9 9295875 [A/C] NM_002839 PTPRD Silent rs1981049 9 9297697 [T/C] NM_002839 PTPRD Silent rs1157904 9 9300084 [T/G] NM_002839 PTPRD Silent rs12156461 9 9301290 [A/C] NM_002839 PTPRD Silent rs1333103 9 9303510 [A/G] NM_002839 PTPRD Silent rs1547288 9 9310461 [A/G] NM_002839 PTPRD Silent rs10977651 9 9311838 [T/C] NM_002839 PTPRD Silent rs9408754 9 9321951 [A/C] NM_002839 PTPRD Silent rs7039887 9 9322503 [T/G] NM_002839 PTPRD Silent rs4562383 9 9326943 [A/C] NM_002839 PTPRD Silent rs10816093 9 9327082 [A/G] NM_002839 PTPRD Silent rs2780069 9 9328048 [T/G] NM_002839 PTPRD Silent rs1332800 9 9337454 [A/G] NM_002839 PTPRD Silent rs1332797 9 9338113 [T/G] NM_002839 PTPRD Silent rs4742585 9 9340617 [T/C] NM_002839 PTPRD Silent rs9408761 9 9340687 [A/G] NM_002839 PTPRD Silent rs16929199 9 9347789 [T/C] NM_002839 PTPRD Silent rs1332802 9 9348102 [T/C] NM_002839 PTPRD Silent rs10816097 9 9348853 [T/C] NM_002839 PTPRD Silent rs7858684 9 9349832 [T/C] NM_002839 PTPRD Silent rs10977673 9 9350608 [T/G] NM_002839 PTPRD Silent rs2151325 9 9351184 [A/G] NM_002839 PTPRD Silent rs9407423 9 9352465 [T/C] NM_002839 PTPRD Silent rs10977679 9 9352861 [A/G] NM_002839 PTPRD Silent rs12349439 9 9354757 [T/C] NM_002839 PTPRD Silent rs1889107 9 9357065 [A/G] NM_002839 PTPRD Silent rs13296976 9 9357444 [A/G] NM_002839 PTPRD Silent rs10125869 9 9357877 [T/C] NM_002839 PTPRD Silent rs1855217 9 9363616 [T/C] NM_002839 PTPRD Silent rs3904501 9 9364637 [T/G] NM_002839 PTPRD Silent rs17606608 9 9374664 [T/C] NM_002839 PTPRD Silent rs2780078 9 9377679 [A/C] NM_002839 PTPRD Silent rs10435830 9 9380781 [A/G] NM_002839 PTPRD Silent rs10977690 9 9381760 [T/C] NM_002839 PTPRD Silent rs10977709 9 9385640 [T/C] NM_002839 PTPRD Silent rs4742590 9 9387487 [T/C] NM_002839 PTPRD Silent rs11793389 9 9388678 [T/C] NM_002839 PTPRD Silent rs10977713 9 9389169 [T/C] NM_002839 PTPRD Silent rs10816114 9 9389992 [T/G] NM_002839 PTPRD Silent rs10816119 9 9392168 [T/C] NM_002839 PTPRD Silent rs2382004 9 9392387 [T/G] NM_002839 PTPRD Silent rs7857734 9 9393275 [A/G] NM_002839 PTPRD Silent rs11795240 9 9393744 [A/G] NM_002839 PTPRD Silent rs2151322 9 9394684 [T/C] NM_002839 PTPRD Silent rs16929280 9 9394902 [A/G] NM_002839 PTPRD Silent rs2184077 9 9395077 [T/C] NM_002839 PTPRD Silent rs7848297 9 9397312 [T/C] NM_002839 PTPRD Silent rs1332798 9 9399018 [T/C] NM_002839 PTPRD Silent rs1412722 9 9400177 [A/C] NM_002839 PTPRD Silent rs10759063 9 9404813 [A/G] NM_002839 PTPRD Silent rs10816124 9 9404896 [A/C] NM_002839 PTPRD Silent rs10759064 9 9405003 [A/G] NM_002839 PTPRD Silent rs10122096 9 9405431 [A/G] NM_002839 PTPRD Silent rs10977735 9 9409606 [T/G] NM_002839 PTPRD Silent rs2065514 9 9412518 [T/C] NM_002839 PTPRD Silent rs10816126 9 9413834 [T/C] NM_002839 PTPRD Silent rs1333111 9 9416962 [A/G] NM_002839 PTPRD Silent rs928476 9 9417343 [T/C] NM_002839 PTPRD Silent rs16929315 9 9417430 [T/C] NM_002839 PTPRD Silent rs1333113 9 9418277 [T/C] NM_002839 PTPRD Silent rs4342663 9 9422159 [T/C] NM_002839 PTPRD Silent rs1412727 9 9423523 [A/G] NM_002839 PTPRD Silent rs11792435 9 9423558 [A/G] NM_002839 PTPRD Silent rs3858066 9 9425605 [T/C] NM_002839 PTPRD Silent rs17829640 9 9433131 [A/G] NM_002839 PTPRD Silent rs7044915 9 9436044 [T/C] NM_002839 PTPRD Silent rs16929369 9 9436595 [A/G] NM_002839 PTPRD Silent rs1412877 9 9437369 [T/C] NM_002839 PTPRD Silent rs1412875 9 9437436 [A/G] NM_002839 PTPRD Silent rs1412873 9 9437674 [T/C] NM_002839 PTPRD Silent rs4142435 9 9439700 [A/G] NM_002839 PTPRD Silent rs10977747 9 9440057 [T/C] NM_002839 PTPRD Silent rs16929395 9 9440664 [A/C] NM_002839 PTPRD Silent rs1360593 9 9440838 [A/G] NM_002839 PTPRD Silent rs1360592 9 9440925 [T/C] NM_002839 PTPRD Silent rs1360591 9 9441003 [T/C] NM_002839 PTPRD Silent rs12376687 9 9442794 [A/C] NM_002839 PTPRD Silent rs1332211 9 9443985 [T/C] NM_002839 PTPRD Silent rs1332810 9 9454258 [A/G] NM_002839 PTPRD Silent rs10977771 9 9455222 [T/C] NM_002839 PTPRD Silent rs987353 9 9456615 [A/G] NM_002839 PTPRD Silent rs1333108 9 9459099 [A/G] NM_002839 PTPRD Silent rs10759075 9 9461717 [A/G] NM_002839 PTPRD Silent rs10491613 9 9464561 [T/G] NM_002839 PTPRD Silent rs12338165 9 9465911 [T/C] NM_002839 PTPRD Silent rs10816135 9 9469877 [A/G] NM_002839 PTPRD Silent rs7027963 9 9472132 [A/G] NM_002839 PTPRD Silent rs2026984 9 9472883 [T/C] NM_002839 PTPRD Silent rs16929560 9 9474970 [A/C] NM_002839 PTPRD Silent rs10115772 9 9475072 [A/C] NM_002839 PTPRD Silent rs10977801 9 9475644 [T/C] NM_002839 PTPRD Silent rs10759077 9 9476195 [A/G] NM_002839 PTPRD Silent rs13287051 9 9476543 [T/C] NM_002839 PTPRD Silent rs10977816 9 9483287 [T/C] NM_002839 PTPRD Silent rs2382017 9 9483573 [T/C] NM_002839 PTPRD Silent rs1332195 9 9483973 [A/G] NM_002839 PTPRD Silent rs10217784 9 9487652 [T/C] NM_002839 PTPRD Silent rs12339036 9 9488626 [A/G] NM_002839 PTPRD Silent rs10977821 9 9489220 [T/C] NM_002839 PTPRD Silent rs6477398 9 9494729 [A/G] NM_002839 PTPRD Silent rs4551426 9 9495226 [A/G] NM_002839 PTPRD Silent rs2382019 9 9499126 [A/G] NM_002839 PTPRD Silent rs10977825 9 9502055 [A/G] NM_002839 PTPRD Silent rs1332199 9 9503477 [T/C] NM_002839 PTPRD Silent rs12337005 9 9504430 [T/C] NM_002839 PTPRD Silent rs10977827 9 9506273 [A/G] NM_002839 PTPRD Silent rs16929628 9 9506433 [A/G] NM_002839 PTPRD Silent rs668205 9 9516348 [A/C] NM_002839 PTPRD Silent rs16929647 9 9517332 [A/C] NM_002839 PTPRD Silent rs828836 9 9518199 [T/G] NM_002839 PTPRD Silent rs7044063 9 9519701 [A/G] NM_002839 PTPRD Silent rs632770 9 9525866 [T/C] NM_002839 PTPRD Silent rs694959 9 9526811 [A/C] NM_002839 PTPRD Silent rs7049205 9 9530755 [T/C] NM_002839 PTPRD Silent rs2038963 9 9533062 [T/C] NM_002839 PTPRD Silent rs7047252 9 9534643 [T/C] NM_002839 PTPRD Silent rs828825 9 9537965 [A/G] NM_002839 PTPRD Silent rs625165 9 9538589 [T/C] NM_002839 PTPRD Silent rs626804 9 9539114 [T/C] NM_002839 PTPRD Silent rs16929713 9 9540141 [T/C] NM_002839 PTPRD Silent rs669190 9 9548257 [A/G] NM_002839 PTPRD Silent rs17179053 9 9553037 [T/C] NM_002839 PTPRD Silent rs828828 9 9556992 [T/C] NM_002839 PTPRD Silent rs647190 9 9568362 [T/C] NM_002839 PTPRD Silent rs16929763 9 9568591 [T/C] NM_002839 PTPRD Silent rs679640 9 9581738 [T/C] NM_002839 PTPRD Silent rs16929848 9 9588157 [A/G] NM_002839 PTPRD Silent rs610789 9 9588336 [A/G] NM_002839 PTPRD Silent rs1412398 9 9599213 [T/C] NM_002839 PTPRD Silent rs664869 9 9600239 [T/G] NM_002839 PTPRD Silent rs16929890 9 9600700 [A/G] NM_002839 PTPRD Silent rs17785914 9 9601885 [T/C] NM_002839 PTPRD Silent rs1326772 9 9602686 [A/C] NM_002839 PTPRD Silent rs10977869 9 9604060 [A/C] NM_002839 PTPRD Silent rs7029761 9 9605832 [T/G] NM_002839 PTPRD Silent rs10977874 9 9609283 [T/C] NM_002839 PTPRD Silent rs10491608 9 9616646 [T/C] NM_002839 PTPRD Silent rs17786597 9 9620141 [T/G] NM_002839 PTPRD Silent rs16929917 9 9621379 [T/C] NM_002839 PTPRD Silent rs16929919 9 9621487 [A/G] NM_002839 PTPRD Silent rs1831033 9 9624597 [T/G] NM_002839 PTPRD Silent rs10977896 9 9630855 [T/G] NM_002839 PTPRD Silent rs10977897 9 9632921 [A/G] NM_002839 PTPRD Silent rs10816151 9 9638432 [A/C] NM_002839 PTPRD Silent rs7864331 9 9640335 [T/G] NM_002839 PTPRD Silent rs10816156 9 9643972 [T/C] NM_002839 PTPRD Silent rs10759083 9 9647916 [T/C] NM_002839 PTPRD Silent rs17183242 9 9649668 [T/C] NM_002839 PTPRD Silent rs16930006 9 9664440 [A/G] NM_002839 PTPRD Silent rs7854287 9 9667071 [A/G] NM_002839 PTPRD Silent rs2821477 9 9673320 [A/G] NM_002839 PTPRD Silent rs7039700 9 9683443 [T/C] NM_002839 PTPRD Silent rs1934269 9 9684129 [A/G] NM_002839 PTPRD Silent rs7856030 9 9685304 [T/G] NM_002839 PTPRD Silent rs4742610 9 9687487 [T/C] NM_002839 PTPRD Silent rs9657637 9 9701254 [T/C] NM_002839 PTPRD Silent rs9657638 9 9701354 [T/C] NM_002839 PTPRD Silent rs10511526 9 9701768 [T/C] NM_002839 PTPRD Silent rs13289361 9 9707824 [T/C] NM_002839 PTPRD Silent rs4628308 9 9708107 [A/C] NM_002839 PTPRD Silent rs10733553 9 9709405 [A/G] NM_002839 PTPRD Silent rs4391483 9 9711904 [A/G] NM_002839 PTPRD Silent rs16930096 9 9714838 [A/G] NM_002839 PTPRD Silent rs10511528 9 9718066 [T/C] NM_002839 PTPRD Silent rs4273904 9 9724976 [A/G] NM_002839 PTPRD Silent rs10816169 9 9729134 [T/C] NM_002839 PTPRD Silent rs1934268 9 9730366 [T/C] NM_002839 PTPRD Silent rs6477416 9 9730473 [A/G] NM_002839 PTPRD Silent rs2761762 9 9733974 [A/G] NM_002839 PTPRD Silent rs10977936 9 9734267 [T/G] NM_002839 PTPRD Silent rs1323800 9 9736054 [T/C] NM_002839 PTPRD Silent rs1408123 9 9736252 [T/C] NM_002839 PTPRD Silent rs1768885 9 9740949 [T/G] NM_002839 PTPRD Silent rs1359176 9 9750139 [T/C] NM_002839 PTPRD Silent rs1768891 9 9751345 [A/G] NM_002839 PTPRD Silent rs1408122 9 9756868 [A/G] NM_002839 PTPRD Silent rs1174581 9 9763352 [T/C] NM_002839 PTPRD Silent rs768225 9 9770741 [T/C] NM_002839 PTPRD Silent rs10977968 9 9772397 [A/G] NM_002839 PTPRD Silent rs10977970 9 9774194 [T/C] NM_002839 PTPRD Silent rs2821498 9 9777072 [T/C] NM_002839 PTPRD Silent rs2761723 9 9778653 [T/G] NM_002839 PTPRD Silent rs1746793 9 9782303 [A/G] NM_002839 PTPRD Silent rs1746794 9 9782351 [T/C] NM_002839 PTPRD Silent rs4740988 9 9783693 [T/C] NM_002839 PTPRD Silent rs16930279 9 9784730 [T/C] NM_002839 PTPRD Silent rs2382056 9 9785685 [A/G] NM_002839 PTPRD Silent rs10977976 9 9787587 [A/G] NM_002839 PTPRD Silent rs7870880 9 9789086 [T/G] NM_002839 PTPRD Silent rs17232558 9 9789202 [T/C] NM_002839 PTPRD Silent rs1174590 9 9790222 [A/G] NM_002839 PTPRD Silent rs2821487 9 9793342 [A/C] NM_002839 PTPRD Silent rs10977989 9 9798092 [A/C] NM_002839 PTPRD Silent rs1746799 9 9800624 [T/C] NM_002839,NR_135135 PTPRD,LOC105375972 EXON Silent,Silent rs1323802 9 9801153 [T/C] NM_002839,NR_135135 PTPRD,LOC105375972 Silent,Silent rs2296170 9 9803954 [T/C] NM_002839 PTPRD Silent rs2821491 9 9804718 [T/C] NM_002839 PTPRD Silent rs4740990 9 9805134 [T/C] NM_002839 PTPRD Silent rs4742622 9 9805193 [A/G] NM_002839 PTPRD Silent rs10977997 9 9805496 [T/C] NM_002839 PTPRD Silent rs1408133 9 9808653 [A/G] NM_002839 PTPRD Silent rs7851409 9 9809180 [T/G] NM_002839 PTPRD Silent rs1746805 9 9812870 [T/C] NM_002839 PTPRD Silent rs2761741 9 9816063 [A/G] NM_002839 PTPRD Silent rs2250434 9 9817393 [T/C] NM_002839 PTPRD Silent rs912356 9 9818094 [T/C] NM_002839 PTPRD Silent rs10125401 9 9829018 [A/G] NM_002839 PTPRD Silent rs7868673 9 9830675 [A/G] NM_002839 PTPRD Silent rs1570591 9 9831068 [T/G] NM_002839 PTPRD Silent rs1570592 9 9831209 [A/G] NM_002839 PTPRD Silent rs10816202 9 9836246 [A/C] NM_002839 PTPRD Silent rs7851513 9 9842176 [A/C] NM_002839 PTPRD Silent rs10978028 9 9843265 [T/G] NM_002839 PTPRD Silent rs10816206 9 9848393 [T/G] NM_002839 PTPRD Silent rs4740993 9 9851382 [T/C] NM_002839 PTPRD Silent rs9407448 9 9852100 [A/G] NM_002839 PTPRD Silent rs7037023 9 9853357 [T/C] NM_002839 PTPRD Silent rs7033762 9 9853397 [A/G] NM_002839 PTPRD Silent rs10978043 9 9860402 [T/C] NM_002839 PTPRD Silent rs16874 9 9860735 [T/C] NM_002839 PTPRD Silent rs9407450 9 9860872 [A/C] NM_002839 PTPRD Silent rs10816216 9 9861006 [T/G] NM_002839 PTPRD Silent rs9408797 9 9862282 [T/C] NM_002839 PTPRD Silent rs4742630 9 9863227 [T/G] NM_002839 PTPRD Silent rs10125073 9 9863613 [T/C] NM_002839 PTPRD Silent rs11999955 9 9864454 [T/G] NM_002839 PTPRD Silent rs10491917 9 9868467 [A/G] NM_002839 PTPRD Silent rs10978060 9 9881511 [A/G] NM_002839 PTPRD Silent rs12002239 9 9882163 [A/G] NM_002839 PTPRD Silent rs10117984 9 9884561 [T/C] NM_002839 PTPRD Silent rs10491915 9 9885376 [T/C] NM_002839 PTPRD Silent rs7873669 9 9886403 [A/C] NM_002839 PTPRD Silent rs4742634 9 9890962 [T/C] NM_002839 PTPRD Silent rs7872069 9 9890993 [T/C] NM_002839 PTPRD Silent rs10978065 9 9893002 [A/G] NM_002839 PTPRD Silent rs10978066 9 9893071 [A/G] NM_002839 PTPRD Silent rs7874380 9 9895814 [T/C] NM_002839 PTPRD Silent rs10491914 9 9896971 [T/C] NM_002839 PTPRD Silent rs10117170 9 9898870 [T/G] NM_002839 PTPRD Silent rs10117851 9 9899274 [T/C] NM_002839 PTPRD Silent rs16930522 9 9904274 [A/G] NM_002839 PTPRD Silent rs10978074 9 9904481 [T/C] NM_002839 PTPRD Silent rs13284014 9 9904498 [A/C] NM_002839 PTPRD Silent rs7862769 9 9905178 [A/G] NM_002839 PTPRD Silent rs11999385 9 9905809 [T/C] NM_002839 PTPRD Silent rs10816223 9 9906970 [T/C] NM_002839 PTPRD Silent rs4740998 9 9907987 [T/C] NM_002839 PTPRD Silent rs10978077 9 9908296 [A/G] NM_002839 PTPRD Silent rs10759100 9 9908722 [T/C] NM_002839 PTPRD Silent rs10978078 9 9908821 [T/C] NM_002839 PTPRD Silent rs10759101 9 9909726 [A/G] NM_002839 PTPRD Silent rs10978079 9 9909795 [A/G] NM_002839 PTPRD Silent rs12348066 9 9910028 [T/C] NM_002839 PTPRD Silent rs10978080 9 9910993 [T/C] NM_002839 PTPRD Silent rs16930559 9 9911283 [T/C] NM_002839 PTPRD Silent rs10816226 9 9912338 [T/C] NM_002839 PTPRD Silent rs10816229 9 9912827 [A/C] NM_002839 PTPRD Silent rs10978082 9 9913373 [A/C] NM_002839 PTPRD Silent rs10978083 9 9914428 [T/C] NM_002839 PTPRD Silent rs4461956 9 9915186 [A/C] NM_002839 PTPRD Silent rs7867164 9 9916467 [T/C] NM_002839 PTPRD Silent rs2382062 9 9918634 [A/G] NM_002839 PTPRD Silent rs4742640 9 9918976 [T/G] NM_002839 PTPRD Silent rs10816232 9 9919035 [T/C] NM_002839 PTPRD Silent rs10816235 9 9920242 [T/G] NM_002839 PTPRD Silent rs10816236 9 9920345 [A/G] NM_002839 PTPRD Silent rs7849581 9 9924724 [T/C] NM_002839 PTPRD Silent rs12683380 9 9929916 [A/G] NM_002839 PTPRD Silent rs12001690 9 9930744 [T/C] NM_002839 PTPRD Silent rs2382082 9 9937753 [A/G] NM_002839 PTPRD Silent rs7859469 9 9939693 [A/G] NM_002839 PTPRD Silent rs7849423 9 9939766 [T/C] NM_002839 PTPRD Silent rs4636255 9 9940329 [A/G] NM_002839 PTPRD Silent rs10978118 9 9940389 [T/C] NM_002839 PTPRD Silent rs7467612 9 9940521 [A/G] NM_002839 PTPRD Silent rs16930650 9 9943040 [T/C] NM_002839 PTPRD Silent rs10491910 9 9943196 [T/G] NM_002839 PTPRD Silent rs6477426 9 9943289 [A/G] NM_002839 PTPRD Silent rs16930657 9 9943710 [T/G] NM_002839 PTPRD Silent rs10759112 9 9945265 [A/C] NM_002839 PTPRD Silent rs10978121 9 9945648 [T/C] NM_002839 PTPRD Silent rs10978127 9 9948303 [A/G] NM_002839 PTPRD Silent rs10978130 9 9951874 [A/G] NM_002839 PTPRD Silent rs16930664 9 9954379 [T/G] NM_002839 PTPRD Silent rs7860466 9 9957301 [T/G] NM_002839 PTPRD Silent rs12349928 9 9957866 [A/C] NM_002839 PTPRD Silent rs7851920 9 9960401 [A/C] NM_002839 PTPRD Silent rs2382087 9 9960537 [A/G] NM_002839 PTPRD Silent rs10978137 9 9961495 [T/G] NM_002839 PTPRD Silent rs7027476 9 9961522 [A/G] NM_002839 PTPRD Silent rs7860014 9 9962204 [T/C] NM_002839 PTPRD Silent rs7470838 9 9962381 [A/G] NM_002839 PTPRD Silent rs10491907 9 9963943 [A/C] NM_002839 PTPRD Silent rs7873262 9 9965824 [T/C] NM_002839 PTPRD Silent rs10739206 9 9968038 [T/C] NM_002839 PTPRD Silent rs7870939 9 9970747 [A/G] NM_002839 PTPRD Silent rs2382089 9 9972321 [T/C] NM_002839 PTPRD Silent rs10115147 9 9972784 [A/C] NM_002839 PTPRD Silent rs7873526 9 9974152 [A/G] NM_002839 PTPRD Silent rs6477436 9 9977113 [A/G] NM_002839 PTPRD Silent rs9299106 9 9979990 [T/C] NM_002839 PTPRD Silent rs10978155 9 10000548 [A/G] NM_002839 PTPRD Silent rs10978156 9 10000931 [T/C] NM_002839 PTPRD Silent rs10816275 9 10004946 [A/C] NM_002839 PTPRD Silent rs16930778 9 10005176 [T/C] NM_002839 PTPRD Silent rs13283706 9 10008130 [A/C] NM_002839 PTPRD Silent rs2382104 9 10008726 [T/G] NM_002839 PTPRD Silent rs10809004 9 10010180 [T/C] NM_002839 PTPRD Silent rs4333667 9 10018121 [A/G] NM_002839 PTPRD Silent rs10809012 9 10023441 [A/G] NM_002839 PTPRD Silent rs727756 9 10025975 [A/G] NM_002839 PTPRD Silent rs1217003 9 10030458 [A/G] NM_002839 PTPRD Silent rs1441400 9 10030499 [A/G] NM_002839 PTPRD Silent rs291270 9 10043674 [A/G] NM_002839 PTPRD Silent rs291267 9 10044092 [A/G] NM_002839 PTPRD Silent rs7868769 9 10044783 [A/G] NM_002839 PTPRD Silent rs2136530 9 10047844 [T/C] NM_002839 PTPRD Silent rs1995845 9 10050872 [A/G] NM_002839 PTPRD Silent rs442100 9 10054740 [A/G] NM_002839 PTPRD Silent rs447910 9 10054994 [A/G] NM_002839 PTPRD Silent rs6474531 9 10056666 [T/C] NM_002839 PTPRD Silent rs428721 9 10057995 [T/G] NM_002839 PTPRD Silent rs399780 9 10061106 [A/G] NM_002839 PTPRD Silent rs417403 9 10061712 [A/C] NM_002839 PTPRD Silent rs368297 9 10063148 [T/C] NM_002839 PTPRD Silent rs565315 9 10064950 [T/C] NM_002839 PTPRD Silent rs1848753 9 10065206 [T/C] NM_002839 PTPRD Silent rs16930968 9 10066608 [T/C] NM_002839 PTPRD Silent rs10958865 9 10070622 [T/C] NM_002839 PTPRD Silent rs9298651 9 10076276 [A/G] NM_002839 PTPRD Silent rs7023147 9 10077180 [A/C] NM_002839 PTPRD Silent rs10511531 9 10077962 [A/G] NM_002839 PTPRD Silent rs10809027 9 10087429 [T/G] NM_002839 PTPRD Silent rs364297 9 10091133 [A/G] NM_002839 PTPRD Silent rs403114 9 10101169 [A/G] NM_002839 PTPRD Silent rs440834 9 10101415 [A/C] NM_002839 PTPRD Silent rs450485 9 10101925 [A/G] NM_002839 PTPRD Silent rs12554847 9 10107399 [A/G] NM_002839 PTPRD Silent rs2890901 9 10112766 [T/C] NM_002839 PTPRD Silent rs291296 9 10113900 [A/G] NM_002839 PTPRD Silent rs725261 9 10114943 [T/C] NM_002839 PTPRD Silent rs10118866 9 10119157 [T/G] NM_002839 PTPRD Silent rs294868 9 10124920 [T/C] NM_002839 PTPRD Silent rs7043462 9 10127876 [T/C] NM_002839 PTPRD Silent rs150409 9 10128645 [T/C] NM_002839 PTPRD Silent rs10958899 9 10128701 [A/G] NM_002839 PTPRD Silent rs10958904 9 10129732 [A/G] NM_002839 PTPRD Silent rs291304 9 10130219 [T/C] NM_002839 PTPRD Silent rs10119277 9 10130546 [T/C] NM_002839 PTPRD Silent rs10958908 9 10132437 [A/G] NM_002839 PTPRD Silent rs11525900 9 10139153 [T/C] NM_002839 PTPRD Silent rs294845 9 10139580 [T/C] NM_002839 PTPRD Silent rs12552479 9 10144584 [T/C] NM_002839 PTPRD Silent rs9721595 9 10145099 [A/G] NM_002839 PTPRD Silent rs16931167 9 10145186 [T/C] NM_002839 PTPRD Silent rs291288 9 10145460 [A/G] NM_002839 PTPRD Silent rs16931176 9 10146521 [T/G] NM_002839 PTPRD Silent rs7850213 9 10147116 [A/G] NM_002839 PTPRD Silent rs291289 9 10148779 [T/C] NM_002839 PTPRD Silent rs13297654 9 10158866 [T/C] NM_002839 PTPRD Silent rs1304641 9 10162452 [T/C] NM_002839 PTPRD Silent rs7032659 9 10167327 [A/G] NM_002839 PTPRD Silent rs10809034 9 10171341 [T/C] NM_002839 PTPRD Silent rs10119783 9 10173689 [A/G] NM_002839 PTPRD Silent rs16931225 9 10175819 [A/G] NM_002839 PTPRD Silent rs17620334 9 10175938 [T/C] NM_002839 PTPRD Silent rs10117980 9 10178560 [T/C] NM_002839 PTPRD Silent rs10958936 9 10178870 [A/G] NM_002839 PTPRD Silent rs294848 9 10184746 [T/C] NM_002839 PTPRD Silent rs294852 9 10185596 [T/C] NM_002839 PTPRD Silent rs1322163 9 10187598 [A/G] NM_002839 PTPRD Silent rs294856 9 10192290 [A/C] NM_002839 PTPRD Silent rs294857 9 10192858 [T/G] NM_002839 PTPRD Silent rs294830 9 10196809 [T/C] NM_002839 PTPRD Silent rs294829 9 10197122 [A/G] NM_002839 PTPRD Silent rs294814 9 10202765 [A/G] NM_002839 PTPRD Silent rs410601 9 10204129 [T/C] NM_002839 PTPRD Silent rs1322133 9 10205835 [A/G] NM_002839 PTPRD Silent rs2498596 9 10211759 [A/G] NM_002839 PTPRD Silent rs911692 9 10212865 [T/C] NM_002839 PTPRD Silent rs2498598 9 10214007 [T/C] NM_002839 PTPRD Silent rs2475324 9 10215130 [T/C] NM_002839 PTPRD Silent rs1322135 9 10216328 [A/G] NM_002839 PTPRD Silent rs6474533 9 10217811 [A/G] NM_002839 PTPRD Silent rs7846730 9 10225500 [T/C] NM_002839 PTPRD Silent rs1885431 9 10225533 [T/C] NM_002839 PTPRD Silent rs16925550 9 10227095 [A/G] NM_002839 PTPRD Silent rs4143460 9 10228203 [T/C] NM_002839 PTPRD Silent rs10958962 9 10229902 [T/C] NM_002839 PTPRD Silent rs1322137 9 10230744 [T/G] NM_002839 PTPRD Silent rs7871439 9 10233188 [A/G] NM_002839 PTPRD Silent rs1322142 9 10233361 [A/G] NM_002839 PTPRD Silent rs10738156 9 10237682 [T/G] NM_002839 PTPRD Silent rs12353282 9 10238391 [A/C] NM_002839 PTPRD Silent rs10217306 9 10238994 [T/C] NM_002839 PTPRD Silent rs2382198 9 10239309 [A/G] NM_002839 PTPRD Silent rs2145990 9 10240296 [A/C] NM_002839 PTPRD Silent rs1570267 9 10240428 [T/C] NM_002839 PTPRD Silent rs9298652 9 10246635 [T/C] NM_002839 PTPRD Silent rs12236941 9 10252022 [T/C] NM_002839 PTPRD Silent rs4741024 9 10254449 [T/C] NM_002839 PTPRD Silent rs16925616 9 10257609 [A/G] NM_002839 PTPRD Silent rs13294419 9 10258144 [A/G] NM_002839 PTPRD Silent rs2475335 9 10260263 [T/C] NM_002839 PTPRD Silent rs2475339 9 10262484 [T/C] NM_002839 PTPRD Silent rs2498627 9 10263407 [T/C] NM_002839 PTPRD Silent rs13285525 9 10265282 [T/G] NM_002839 PTPRD Silent rs2475348 9 10266608 [T/C] NM_002839 PTPRD Silent rs12164236 9 10266820 [T/C] NM_002839 PTPRD Silent rs2475354 9 10268794 [T/G] NM_002839 PTPRD Silent rs2475357 9 10270339 [T/G] NM_002839 PTPRD Silent rs1322155 9 10270636 [A/G] NM_002839 PTPRD Silent rs1323505 9 10273068 [A/G] NM_002839 PTPRD Silent rs1323504 9 10273124 [A/G] NM_002839 PTPRD Silent rs7861410 9 10273253 [A/C] NM_002839 PTPRD Silent rs7865468 9 10274080 [A/G] NM_002839 PTPRD Silent rs12002909 9 10274655 [A/G] NM_002839 PTPRD Silent rs1359095 9 10276100 [T/C] NM_002839 PTPRD Silent rs10959002 9 10277054 [T/C] NM_002839 PTPRD Silent rs10959007 9 10277319 [A/C] NM_002839 PTPRD Silent rs16925679 9 10277602 [T/C] NM_002839 PTPRD Silent rs10738159 9 10278722 [A/G] NM_002839 PTPRD Silent rs10959013 9 10282750 [A/G] NM_002839 PTPRD Silent rs10959018 9 10284628 [T/G] NM_002839 PTPRD Silent rs7875861 9 10285562 [T/C] NM_002839 PTPRD Silent rs12344926 9 10286986 [A/G] NM_002839 PTPRD Silent rs1323499 9 10287901 [T/C] NM_002839 PTPRD Silent rs616040 9 10295912 [T/G] NM_002839 PTPRD Silent rs633062 9 10297439 [A/G] NM_002839 PTPRD Silent rs10809062 9 10298444 [A/G] NM_002839 PTPRD Silent rs10809063 9 10298970 [T/C] NM_002839 PTPRD Silent rs661198 9 10299084 [A/G] NM_002839 PTPRD Silent rs12238349 9 10309001 [A/G] NM_002839 PTPRD Silent rs589991 9 10309897 [T/C] NM_002839 PTPRD Silent rs605318 9 10311000 [A/G] NM_002839 PTPRD Silent rs16925800 9 10315193 [A/C] NM_002839 PTPRD Silent rs635580 9 10315723 [T/C] NM_002839 PTPRD Silent rs603924 9 10317212 [T/C] NM_002839 PTPRD Silent rs587791 9 10318490 [T/G] NM_002839 PTPRD Silent rs12003120 9 10318512 [T/C] NM_002839 PTPRD Silent rs10959051 9 10330850 [A/G] NM_002839 PTPRD Silent rs10959053 9 10333382 [A/G] NM_002839 PTPRD Silent rs1590347 9 10335382 [T/C] NM_002839 PTPRD Silent rs10959055 9 10341531 [A/G] NM_002839 PTPRD Silent rs10809071 9 10341540 [T/C] NM_002839 PTPRD Silent rs7871892 9 10342442 [T/G] NM_002839 PTPRD Silent rs12552756 9 10342841 [A/C] NM_002839 PTPRD Silent rs10959061 9 10346862 [A/G] NM_002839 PTPRD Silent rs7852334 9 10348659 [A/G] NM_002839 PTPRD Silent rs10809075 9 10352639 [T/C] NM_002839 PTPRD Silent rs17703834 9 10354430 [A/G] NM_002839 PTPRD Silent rs16925863 9 10354770 [T/C] NM_002839 PTPRD Silent rs10125156 9 10355941 [A/G] NM_002839 PTPRD Silent rs9298656 9 10357348 [A/G] NM_002839 PTPRD Silent rs10756029 9 10358672 [T/C] NM_002839 PTPRD Silent rs10959075 9 10362221 [A/C] NM_002839 PTPRD Silent rs10959076 9 10362315 [T/C] NM_002839 PTPRD Silent rs13286001 9 10362373 [A/G] NM_002839 PTPRD Silent rs7033338 9 10364655 [T/C] NM_002839 PTPRD Silent rs16925876 9 10365636 [T/C] NM_002839 PTPRD Silent rs12551331 9 10366812 [T/C] NM_002839 PTPRD Silent rs1359091 9 10367106 [T/G] NM_002839 PTPRD Silent rs7034193 9 10368596 [A/G] NM_002839 PTPRD Silent rs10738162 9 10369161 [T/C] NM_002839 PTPRD Silent rs4595175 9 10369718 [A/C] NM_002839 PTPRD Silent rs1535658 9 10371281 [A/G] NM_002839 PTPRD Silent rs16925900 9 10372488 [A/G] NM_002839 PTPRD Silent rs10959080 9 10373600 [T/C] NM_002839 PTPRD Silent rs1570524 9 10374386 [A/C] NM_002839 PTPRD Silent rs7864680 9 10374460 [A/G] NM_002839 PTPRD Silent rs6474539 9 10374705 [T/G] NM_002839 PTPRD Silent rs10959084 9 10381819 [T/G] NM_002839 PTPRD Silent rs12006444 9 10386641 [A/C] NM_002839 PTPRD Silent rs10959087 9 10387436 [A/G] NM_002839 PTPRD Silent rs16925941 9 10389285 [A/C] NM_002839 PTPRD Silent rs10959088 9 10390416 [T/C] NM_002839 PTPRD Silent rs10809084 9 10391459 [T/G] NM_002839 PTPRD Silent rs10756031 9 10391604 [A/C] NM_002839 PTPRD Silent rs10959090 9 10395912 [A/G] NM_002839 PTPRD Silent rs2382208 9 10404336 [T/C] NM_002839 PTPRD Silent rs7855950 9 10409555 [T/C] NM_002839 PTPRD Silent rs1359098 9 10411393 [A/G] NM_002839 PTPRD Silent rs10809092 9 10421687 [T/C] NM_002839 PTPRD Silent rs7849858 9 10423598 [A/G] NM_002839 PTPRD Silent rs12344987 9 10423799 [T/C] NM_002839 PTPRD Silent rs12346029 9 10424164 [T/C] NM_002839 PTPRD Silent rs592714 9 10428780 [A/G] NM_002839 PTPRD Silent rs12001636 9 10430089 [A/G] NM_002839 PTPRD Silent rs649891 9 10430602 [T/C] NM_002839 PTPRD Silent rs619126 9 10432920 [T/C] NM_002839 PTPRD Silent rs618288 9 10436451 [A/G] NM_002839 PTPRD Silent rs620558 9 10436921 [A/G] NM_002839 PTPRD Silent rs16926027 9 10443488 [T/C] NM_002839 PTPRD Silent rs1565898 9 10448624 [T/C] NM_002839 PTPRD Silent rs13287491 9 10457788 [T/C] NM_002839 PTPRD Silent rs13297915 9 10459930 [A/G] NM_002839 PTPRD Silent rs7850565 9 10462105 [T/C] NM_002839 PTPRD Silent rs10124165 9 10463261 [T/C] NM_002839 PTPRD Silent rs1537812 9 10464815 [T/C] NM_002839 PTPRD Silent rs4740452 9 10465127 [A/G] NM_002839 PTPRD Silent rs4740453 9 10465615 [T/C] NM_002839 PTPRD Silent rs12343415 9 10468666 [A/C] NM_002839 PTPRD Silent rs12352981 9 10470220 [T/C] NM_002839 PTPRD Silent rs16926062 9 10473380 [T/C] NM_002839 PTPRD Silent rs2784624 9 10478387 [A/G] NM_002839 PTPRD Silent rs976831 9 10479527 [T/C] NM_002839 PTPRD Silent rs2784623 9 10479816 [A/G] NM_002839 PTPRD Silent rs10756041 9 10479902 [T/C] NM_002839 PTPRD Silent rs1855850 9 10480030 [T/C] NM_002839 PTPRD Silent rs1853231 9 10481115 [A/G] NM_002839 PTPRD Silent rs1853232 9 10481205 [T/C] NM_002839 PTPRD Silent rs7870466 9 10481639 [A/C] NM_002839 PTPRD Silent rs2784607 9 10484849 [A/G] NM_002839 PTPRD Silent rs833408 9 10490752 [T/C] NM_002839 PTPRD Silent rs833438 9 10495432 [A/G] NM_002839 PTPRD Silent rs1555483 9 10497345 [A/G] NM_002839 PTPRD Silent rs2181156 9 10501953 [T/G] NM_002839 PTPRD Silent rs833417 9 10505161 [A/G] NM_002839 PTPRD Silent rs10959130 9 10506167 [A/G] NM_002839 PTPRD Silent rs12379948 9 10512117 [T/G] NM_002839 PTPRD Silent rs2784598 9 10512307 [T/C] NM_002839 PTPRD Silent rs10115302 9 10516888 [T/C] NM_002839 PTPRD Silent rs833403 9 10523334 [A/G] NM_002839 PTPRD Silent rs4461952 9 10523685 [T/C] NM_002839 PTPRD Silent rs702128 9 10523720 [T/C] NM_002839 PTPRD Silent rs10959147 9 10526845 [A/G] NM_002839 PTPRD Silent rs833425 9 10527045 [T/C] NM_002839 PTPRD Silent rs702130 9 10530844 [T/C] NM_002839 PTPRD Silent rs10959149 9 10530953 [A/G] NM_002839 PTPRD Silent rs10756060 9 10531641 [A/G] NM_002839 PTPRD Silent rs833432 9 10532820 [T/C] NM_002839 PTPRD Silent rs833435 9 10534642 [T/C] NM_002839 PTPRD Silent rs2784609 9 10538067 [T/G] NM_002839 PTPRD Silent rs10959161 9 10543899 [A/C] NM_002839 PTPRD Silent rs2181158 9 10546257 [T/G] NM_002839 PTPRD Silent rs1008981 9 10546814 [T/C] NM_002839 PTPRD Silent rs833455 9 10547481 [T/C] NM_002839 PTPRD Silent rs10959163 9 10548301 [T/G] NM_002839 PTPRD Silent rs2784611 9 10551203 [A/G] NM_002839 PTPRD Silent rs1885508 9 10552890 [A/C] NM_002839 PTPRD Silent rs833411 9 10555358 [A/G] NM_002839 PTPRD Silent rs833412 9 10555471 [T/G] NM_002839 PTPRD Silent rs833416 9 10558102 [T/G] NM_002839 PTPRD Silent rs2757873 9 10560924 [A/G] NM_002839 PTPRD Silent rs10756061 9 10561180 [T/C] NM_002839 PTPRD Silent rs2038592 9 10561818 [T/C] NM_002839 PTPRD Silent rs1322310 9 10562824 [A/C] NM_002839 PTPRD Silent rs1475111 9 10564866 [A/C] NM_002839 PTPRD Silent rs7465708 9 10565658 [A/C] NM_002839 PTPRD Silent rs10959172 9 10569790 [T/C] NM_002839 PTPRD Silent rs988954 9 10572234 [A/C] NM_002839 PTPRD Silent rs17203683 9 10572433 [T/C] NM_002839 PTPRD Silent rs7025985 9 10572534 [A/G] NM_002839 PTPRD Silent rs1322314 9 10574347 [A/G] NM_002839 PTPRD Silent rs4741037 9 10575273 [A/C] NM_002839 PTPRD Silent rs7039334 9 10575728 [A/G] NM_002839 PTPRD Silent rs10756063 9 10577775 [T/C] NM_002839 PTPRD Silent rs10738168 9 10580326 [T/G] NM_002839 PTPRD Silent rs7868480 9 10581178 [A/C] NM_002839 PTPRD Silent rs10959175 9 10581373 [A/G] NM_002839 PTPRD Silent rs10959176 9 10581485 [A/C] NM_002839 PTPRD Silent rs1322280 9 10582246 [T/C] NM_002839 PTPRD Silent rs12683583 9 10583223 [T/C] NM_002839 PTPRD Silent rs1160259 9 10585399 [A/G] NM_002839 PTPRD Silent rs13298283 9 10586527 [A/C] NM_002839 PTPRD Silent rs10115631 9 10589257 [A/G] NM_002839 PTPRD Silent rs1322291 9 10592492 [T/C] NM_002839 PTPRD Silent rs10756066 9 10595208 [A/C] NM_002839 PTPRD Silent rs1407398 9 10596853 [T/C] NM_002839 PTPRD Silent rs10809130 9 10598429 [T/C] NM_002839 PTPRD Silent rs16926174 9 10601936 [T/C] NM_002839 PTPRD Silent rs977124 9 10602787 [A/C] NM_002839 PTPRD Silent rs2382220 9 10603102 [A/G] NM_002839 PTPRD Silent rs985563 9 10603845 [T/G] NM_002839 PTPRD Silent rs7863685 9 10620453 [A/C] rs1407402 9 10620520 [T/G] rs10756070 9 10626531 [T/G] rs7048007 9 10635719 [A/G] rs1040910 9 10637778 [T/C] rs7040199 9 10642041 [T/C] rs2208707 9 10649660 [A/G] rs7868009 9 10651724 [T/C] rs4131202 9 10653484 [T/C] rs10756076 9 10655642 [A/G] rs4372056 9 10656930 [A/G] rs10809150 9 10661677 [A/G] rs4427223 9 10663815 [A/G] rs7045753 9 10668198 [T/C] rs7029106 9 10673850 [A/G] rs4443711 9 10674573 [T/C] rs4992817 9 10678556 [T/C] rs10738180 9 10679889 [T/C] rs7852800 9 10679912 [A/G] rs947215 9 10681522 [T/C] rs7023148 9 10684803 [A/C] rs13285976 9 10684841 [A/G] rs10511552 9 10686202 [A/G] rs10809156 9 10690633 [T/G] rs7857207 9 10691050 [A/G] rs10756099 9 10692461 [A/G] rs11787634 9 10696313 [T/G] rs3923120 9 10699855 [T/G] rs10465037 9 10714842 [T/C] rs10756104 9 10723877 [A/G] rs16926356 9 10727372 [A/G] rs2382234 9 10735803 [T/C] rs10959258 9 10736580 [A/G] rs1154843 9 10737038 [T/C] rs16926393 9 10740979 [A/G] rs10809183 9 10749312 [T/G] rs1831295 9 10752338 [A/G] rs10809185 9 10753219 [T/C] rs10511554 9 10753557 [T/C] rs13283737 9 10754695 [A/G] rs7023802 9 10758044 [T/C] rs10738187 9 10767678 [A/G] rs10959282 9 10770620 [T/C] rs16926439 9 10773858 [A/G] rs13288186 9 10776453 [T/G] rs10959288 9 10777503 [T/C] rs10809190 9 10784500 [T/C] rs10117531 9 10790580 [T/C] rs10959301 9 10792826 [T/C] rs10959310 9 10810659 [T/G] rs7852827 9 10816593 [T/C] rs7022854 9 10830012 [A/G] rs10809209 9 10834971 [T/C] rs3904270 9 10856892 [T/C] rs3899613 9 10858265 [A/G] rs2890930 9 10861806 [A/C] rs3858019 9 10862544 [A/G] rs7850706 9 10867150 [A/G] rs10809233 9 10868263 [T/C] rs3858023 9 10878677 [A/C] rs2382245 9 10878948 [T/C] rs954492 9 10880887 [A/C] rs7873741 9 10883851 [A/G] rs12376782 9 10884836 [T/C] rs7867915 9 10894863 [A/G] rs10959357 9 10903674 [A/G] rs16926616 9 10904815 [T/C] rs10511558 9 10906334 [A/G] rs10809238 9 10909144 [T/G] rs985337 9 10921838 [T/C] rs1536997 9 10923290 [A/G] rs10959370 9 10923969 [T/G] rs10959372 9 10924493 [A/G] rs7466612 9 10925989 [A/G] rs7021524 9 10928314 [T/C] rs7863959 9 10928755 [T/C] rs4740464 9 10929786 [A/C] rs10756144 9 10931501 [A/G] rs10738194 9 10931959 [T/G] rs10959381 9 10936135 [A/G] rs7875099 9 10936687 [A/C] rs4378061 9 10940127 [T/C] rs7848707 9 10942628 [T/C] rs10959388 9 10943698 [A/G] rs1888189 9 10948272 [T/C] rs10809261 9 10957549 [T/C] rs7858983 9 10962971 [A/G] rs16926676 9 10970004 [A/C] rs16926678 9 10970165 [A/G] rs10959419 9 10972504 [T/G] rs17805859 9 10972566 [A/C] rs10448153 9 10975246 [A/G] rs1330254 9 10984840 [T/C] rs1330257 9 10990046 [A/G] rs1330259 9 10990841 [T/C] rs1330261 9 10991139 [A/G] rs913923 9 10996025 [A/G] rs7853830 9 10998674 [T/C] rs928546 9 11003940 [A/C] rs4381046 9 11004888 [A/G] rs10959456 9 11012926 [A/G] rs11791663 9 11013198 [T/G] rs7047902 9 11015940 [T/G] rs10756160 9 11016456 [T/C] rs955045 9 11017859 [T/C] rs12346562 9 11018077 [A/C] rs10809292 9 11019709 [T/G] rs10756163 9 11021845 [A/G] rs10959464 9 11022051 [A/G] rs10959466 9 11022581 [T/C] rs10959468 9 11024400 [T/G] rs10959470 9 11028959 [T/C] rs10117437 9 11031788 [A/G] rs1155586 9 11034658 [A/C] rs10809302 9 11036869 [T/C] rs7044282 9 11039639 [T/C] rs10959478 9 11042142 [T/C] rs10733217 9 11042650 [A/G] rs10959486 9 11050999 [A/G] rs4097990 9 11063519 [A/G] rs7866912 9 11070565 [A/C] rs6474617 9 11070804 [A/G] rs10959509 9 11073873 [T/C] rs6474620 9 11075271 [T/C] rs10809326 9 11075596 [T/C] rs7858670 9 11075772 [A/G] rs1334045 9 11083426 [T/C] rs10121358 9 11083979 [T/G] rs1931401 9 11091254 [T/C] rs7044787 9 11101956 [A/G] rs5023022 9 11104105 [T/C] rs1334038 9 11105401 [T/C] rs10959531 9 11108517 [A/G] rs7042371 9 11111096 [A/C] rs7868584 9 11114436 [T/G] rs10809343 9 11114781 [T/C] rs12377914 9 11116389 [T/C] rs7863726 9 11122042 [A/C] rs10809352 9 11127388 [A/G] rs10809353 9 11129139 [T/C] rs1931405 9 11129613 [A/G] rs2184258 9 11131170 [T/C] rs9298665 9 11135805 [T/C] rs7870863 9 11136285 [A/C] rs7866090 9 11140883 [A/G] rs10959563 9 11141099 [A/G] rs10809356 9 11141424 [A/G] rs10959565 9 11143413 [A/G] rs10116927 9 11143915 [T/C] rs944997 9 11144684 [T/C] rs10959567 9 11144781 [A/G] rs10959573 9 11155468 [T/C] rs11999125 9 11156238 [T/C] rs6474635 9 11167194 [T/C] rs7037473 9 11173836 [T/G] rs10959581 9 11174994 [A/G] rs10733227 9 11177986 [A/C] rs10959584 9 11178159 [T/C] rs12375980 9 11178672 [A/G] rs10756199 9 11181745 [T/C] rs2200787 9 11187028 [T/C] rs10809375 9 11191795 [A/G] rs10959606 9 11192810 [A/G] rs10125755 9 11194115 [A/G] rs7465994 9 11194132 [T/C] rs10733228 9 11200231 [T/C] rs1931388 9 11203149 [A/G] rs10738221 9 11207994 [T/C] rs10511566 9 11218042 [T/C] rs11788082 9 11218170 [A/G] rs10123231 9 11226399 [A/C] rs10809396 9 11235661 [T/C] rs10119093 9 11246297 [T/C] rs1387292 9 11254070 [T/C] rs10959672 9 11257448 [A/G] rs10756216 9 11262339 [T/C] rs1352519 9 11270533 [A/G] rs10959676 9 11274798 [T/C] rs1489177 9 11275227 [T/C] rs10959682 9 11277879 [T/C] rs1489175 9 11278380 [T/G] rs11496296 9 11305052 [T/C] rs10756234 9 11316481 [T/C] rs10959723 9 11327345 [T/G] rs10116684 9 11329927 [T/G] rs12376216 9 11337156 [T/C] rs4741148 9 11339109 [T/C] rs10959734 9 11343385 [A/G] rs12552533 9 11345138 [T/G] rs1414202 9 11359656 [T/C] rs1335445 9 11359686 [T/G] rs10809441 9 11366549 [T/C] rs12378446 9 11369213 [T/C] rs16927457 9 11374073 [T/G] rs10124748 9 11381692 [A/G] rs1335477 9 11396601 [T/C] rs1335475 9 11398305 [A/G] rs4483255 9 11402634 [T/G] rs10738232 9 11403465 [T/C] rs1582078 9 11404656 [T/C] rs10959776 9 11408052 [T/C] rs1577436 9 11414180 [T/C] rs1335467 9 11419061 [T/G] rs2105054 9 11425445 [T/C] rs1414213 9 11427927 [T/C] rs10959797 9 11431990 [A/G] rs16927540 9 11432276 [T/C] rs10959800 9 11434678 [A/G] rs4524893 9 11439075 [T/C] rs10809476 9 11440848 [A/C] rs1414207 9 11440880 [T/C] rs10809477 9 11441728 [A/C] rs7848864 9 11444251 [T/C] rs7038987 9 11448773 [A/G] rs1023298 9 11449612 [T/C] rs9406428 9 11463799 [T/C] rs950868 9 11465606 [A/C] rs10809488 9 11467111 [A/G] rs10959841 9 11469190 [T/C] rs10756254 9 11471766 [T/C] rs10738236 9 11487579 [A/G] rs725910 9 11488348 [T/C] rs7030303 9 11490767 [T/C] rs10959862 9 11494328 [A/C] rs1596341 9 11499438 [A/G] rs7023912 9 11501459 [T/C] rs13284347 9 11511359 [A/G] rs968995 9 11514645 [A/G] rs10114729 9 11519008 [A/G] rs7871636 9 11525541 [T/C] rs10809510 9 11530473 [T/C] rs10959916 9 11549041 [T/C] rs10959919 9 11549994 [A/G] rs11792400 9 11551772 [T/C] rs10959923 9 11552356 [A/G] rs12349156 9 11553641 [T/C] rs12341457 9 11558301 [A/G] rs10809521 9 11558362 [T/C] rs1348384 9 11560184 [T/C] rs7047379 9 11561438 [T/C] rs10959951 9 11574204 [T/C] rs10119906 9 11574930 [T/C] rs10809526 9 11578233 [T/G] rs10959970 9 11586357 [A/C] rs1116978 9 11590844 [A/C] rs7026627 9 11602294 [T/G] rs10117313 9 11605039 [A/G] rs10511567 9 11606348 [T/C] rs1838132 9 11609469 [T/C] rs4741169 9 11609873 [T/C] rs2821181 9 11613259 [T/C] rs2586330 9 11613559 [A/C] rs1822387 9 11617265 [T/C] rs12236939 9 11618203 [T/C] rs10960058 9 11645495 [A/G] rs4741174 9 11649257 [A/G] rs10738244 9 11656743 [T/C] rs12351495 9 11659198 [T/C] rs958842 9 11676507 [A/C] rs7033859 9 11683177 [T/C] rs2821204 9 11683901 [T/C] rs2821203 9 11683979 [T/C] rs12378383 9 11684502 [A/G] rs2586335 9 11693400 [A/G] rs1470308 9 11695108 [A/G] rs7018532 9 11695785 [T/C] rs13296683 9 11700487 [A/G] rs13300485 9 11704697 [T/C] rs10756267 9 11711459 [A/G] rs455131 9 11714572 [T/C] rs1486803 9 11716862 [T/C] rs4741178 9 11725843 [A/G] rs4741179 9 11727020 [T/C] rs10809575 9 11743752 [T/G] rs10809576 9 11743846 [A/C] rs1564999 9 11747149 [T/C] rs1486806 9 11747626 [T/C] rs10960164 9 11747876 [A/G] rs956095 9 11749911 [A/G] rs10960174 9 11753695 [A/G] rs1979548 9 11759484 [T/C] rs10429595 9 11775361 [A/G] rs12376679 9 11780023 [T/C] rs10809590 9 11782345 [A/G] rs1825739 9 11787410 [T/C] rs10960221 9 11787966 [A/C] rs7867311 9 11790536 [A/C] rs1160534 9 11798994 [A/G] rs12341074 9 11806107 [A/G] rs11999415 9 11813213 [A/G] rs11999438 9 11813382 [A/G] rs1601615 9 11813745 [T/C] rs2129385 9 11814915 [T/C] rs10960270 9 11818115 [A/G] rs10960278 9 11820083 [A/G] rs10738253 9 11825229 [T/C] rs16928154 9 11827745 [A/G] rs10960295 9 11829232 [A/G] rs10732328 9 11835471 [T/C] rs10756295 9 11838399 [A/G] rs2200545 9 11844287 [A/G] rs12342107 9 11847376 [A/G] rs10960316 9 11848378 [T/C] rs16928182 9 11850283 [A/G] rs1948080 9 11852043 [T/G] rs6474675 9 11857464 [A/C] rs11999029 9 11860446 [A/G] rs973330 9 11861962 [A/G] rs4425849 9 11869293 [A/G] rs10809634 9 11880490 [T/C] rs7049164 9 11880552 [A/G] rs10809637 9 11883299 [T/G] rs12006517 9 11884852 [A/G] rs1486802 9 11885258 [T/C] rs10960350 9 11886098 [A/C] rs17832803 9 11887764 [A/C] rs4401971 9 11890045 [A/G] rs12553961 9 11891381 [T/G] rs11532849 9 11893047 [T/G] rs12683024 9 11903938 [T/C] rs10809648 9 11917701 [A/G] rs1999377 9 11919732 [T/C] rs10960376 9 11929890 [T/C] rs10960378 9 11930638 [A/G] rs4642743 9 11936751 [A/G] rs10960385 9 11937390 [T/C] rs10960393 9 11949207 [A/G] rs1929412 9 11951222 [A/C] rs1929409 9 11952643 [A/C] rs1929408 9 11952796 [A/G] rs10960397 9 11953279 [T/C] rs10809655 9 11958106 [A/C] rs7037332 9 11960277 [A/C] rs4407997 9 11963439 [A/G] rs12001579 9 11965111 [A/G] rs10960403 9 11967114 [T/C] rs10121921 9 11969789 [A/G] rs16928287 9 11970867 [T/G] rs10756311 9 11974458 [A/G] rs16928298 9 11976830 [T/C] rs10960417 9 11988769 [A/G] rs6474681 9 11995297 [T/G] rs4512479 9 11996831 [A/G] rs10809663 9 12000099 [A/G] rs10809666 9 12003252 [T/C] rs7048594 9 12005070 [A/G] rs12001461 9 12007658 [T/C] rs10756313 9 12013711 [A/G] rs1446255 9 12020873 [A/G] rs7851270 9 12022175 [A/G] rs12339814 9 12046842 [A/G] rs12238357 9 12048206 [A/G] rs9886865 9 12051998 [T/C] rs9969851 9 12054659 [A/C] rs7040466 9 12056279 [T/C] rs10960455 9 12058197 [T/G] rs11789947 9 12061324 [T/C] rs1374177 9 12065319 [A/G] rs12686721 9 12067552 [A/C] rs7863023 9 12067914 [T/G] rs4449884 9 12078499 [T/G] rs10960462 9 12082380 [A/C] rs7859230 9 12084080 [A/G] rs7036903 9 12085717 [T/G] rs10960466 9 12092193 [A/G] rs10809694 9 12092895 [A/G] rs13297287 9 12093072 [A/C] rs10738261 9 12095022 [A/G] rs1446268 9 12098000 [A/G] rs10960477 9 12099118 [A/C] rs2382310 9 12100880 [A/C] rs1348742 9 12101436 [A/G] rs12000494 9 12106293 [A/G] rs11515183 9 12107758 [A/G] rs12351590 9 12108916 [A/G] rs7468068 9 12112566 [T/C] rs10435753 9 12113011 [A/C] rs10960488 9 12124410 [A/G] rs10960493 9 12131415 [A/C] rs1114756 9 12133321 [T/G] rs791773 9 12139870 [A/G] rs10960499 9 12144717 [T/G] rs7048056 9 12149367 [T/G] rs1446264 9 12152990 [A/C] rs10809701 9 12156819 [T/G] rs10117456 9 12161870 [T/G] rs10809703 9 12162328 [T/C] rs10115948 9 12163583 [T/G] rs10960502 9 12165072 [T/C] rs7025259 9 12165758 [T/G] rs10809708 9 12168247 [T/C] rs1339264 9 12177583 [T/C] rs1999977 9 12178059 [A/C] rs10114299 9 12182768 [T/G] rs4285563 9 12185185 [T/G] rs10809716 9 12192428 [A/G] rs10738266 9 12194296 [T/C] rs2066096 9 12194855 [A/G] rs2066097 9 12195026 [A/G] rs1339272 9 12197936 [A/G] rs7852109 9 12200957 [A/G] rs7870825 9 12201384 [T/C] rs16928550 9 12201866 [T/G] rs1010663 9 12213414 [A/G] rs16928562 9 12213879 [T/G] rs10733241 9 12216024 [T/C] rs7875540 9 12216756 [A/G] rs10960535 9 12224275 [A/G] rs10960537 9 12227068 [A/G] rs16928577 9 12229079 [A/G] rs10116548 9 12234642 [T/C] rs946452 9 12234969 [T/C] rs1339284 9 12237417 [A/G] rs10960540 9 12237630 [T/C] rs10960541 9 12239604 [A/G] rs2382337 9 12240518 [A/G] rs10809740 9 12241585 [A/G] rs4741216 9 12243007 [A/G] rs4477124 9 12247973 [T/C] rs4008045 9 12248419 [T/G] rs756156 9 12253933 [T/C] rs7860853 9 12255238 [T/C] rs12340485 9 12256058 [T/G] rs11791609 9 12256453 [A/G] rs1339278 9 12257514 [T/C] rs4740521 9 12261388 [A/G] rs1416576 9 12263833 [T/G] rs871981 9 12266760 [T/G] rs10809744 9 12267132 [A/G] rs1538515 9 12267378 [T/C] rs6474694 9 12272705 [A/G] rs7874304 9 12272744 [T/C] rs10960561 9 12275924 [A/G] rs17262250 9 12276668 [A/C] rs10809747 9 12277388 [T/C] rs951176 9 12278150 [A/G] rs1999216 9 12281372 [T/C] rs10809748 9 12284611 [A/G] rs10283912 9 12285170 [T/C] rs1106474 9 12287518 [T/G] rs1416581 9 12287727 [T/C] rs7042930 9 12287892 [T/G] rs7873941 9 12288602 [T/G] rs11794979 9 12290837 [T/G] rs7031915 9 12297444 [T/C] rs9919013 9 12300395 [T/C] rs7043787 9 12305664 [A/G] rs16928666 9 12306626 [A/G] rs10809751 9 12317717 [A/G] rs7040701 9 12318093 [T/C] rs10960592 9 12319300 [A/G] rs7871859 9 12328006 [T/C] rs6474701 9 12333231 [A/C] rs16928712 9 12350523 [A/G] rs1928873 9 12350564 [T/C] rs7869172 9 12350993 [A/G] rs4741220 9 12351048 [T/C] rs16928719 9 12351464 [A/G] rs10960614 9 12352035 [A/G] rs10960615 9 12352439 [A/G] rs10960616 9 12352971 [A/G] rs7863513 9 12352992 [T/C] rs1331350 9 12356017 [A/G] rs4628342 9 12359563 [A/G] rs7866997 9 12362466 [T/G] rs1412074 9 12363134 [A/G] rs1331359 9 12363456 [A/G] rs12338989 9 12364718 [A/C] rs7854195 9 12366560 [A/G] rs12686127 9 12366893 [A/G] rs7854844 9 12366992 [T/C] rs1929425 9 12367988 [T/C] rs10809762 9 12370395 [T/C] rs1331367 9 12381912 [T/C] rs1952692 9 12382539 [A/C] rs10123440 9 12383180 [A/G] rs7469693 9 12387932 [A/G] rs1928868 9 12388022 [T/C] rs1360461 9 12397405 [T/G] rs2777007 9 12397876 [A/G] rs10756369 9 12401666 [A/G] rs1331346 9 12404591 [T/C] rs10116714 9 12407578 [A/G] rs7044903 9 12416079 [A/G] rs7871312 9 12421476 [T/C] rs12683218 9 12421929 [A/G] rs10491747 9 12425767 [A/G] rs7856061 9 12433463 [T/G] rs1999380 9 12442019 [A/C] rs7860071 9 12443586 [A/G] rs1537181 9 12445143 [A/G] rs10756372 9 12448743 [T/C] rs10809779 9 12452348 [A/G] rs4740523 9 12453240 [A/G] rs10117083 9 12453538 [A/G] rs2065367 9 12456328 [T/C] rs10960672 9 12456576 [T/G] rs4008031 9 12460256 [A/G] rs2026326 9 12463411 [A/G] rs2150696 9 12464876 [A/G] rs11787776 9 12469893 [A/G] rs10756373 9 12470048 [A/C] rs1331371 9 12479157 [A/G] rs1576659 9 12483221 [A/G] rs791654 9 12490247 [A/G] rs791658 9 12493565 [T/C] rs791660 9 12494501 [T/C] rs7020220 9 12495309 [T/C] rs2022314 9 12496752 [A/G] rs7467390 9 12497036 [A/G] rs2021997 9 12499211 [A/C] rs791662 9 12501498 [A/G] rs4741226 9 12502531 [T/C] rs16929075 9 12509667 [A/G] rs791667 9 12510515 [A/G] rs1325129 9 12512973 [T/C] rs1041102 9 12513587 [A/G] rs1408803 9 12514323 [T/C] rs791669 9 12515876 [A/G] rs10960688 9 12517689 [T/C] rs791674 9 12518862 [T/G] rs10960694 9 12521469 [T/C] rs791681 9 12522037 [A/G] rs1325132 9 12525999 [A/G] rs702131 9 12526192 [A/G] rs791688 9 12527414 [T/C] rs791695 9 12529952 [A/G] rs16929115 9 12531493 [T/G] rs791700 9 12532584 [A/C] rs1570781 9 12537279 [A/G] rs12235745 9 12540358 [A/G] rs12000969 9 12541971 [A/G] rs10756376 9 12564122 [A/G] rs1325149 9 12570945 [A/C] rs16923032 9 12574724 [T/G] rs10960708 9 12578438 [T/G] rs10809797 9 12581270 [T/C] rs1325154 9 12582565 [T/C] rs10429629 9 12582787 [T/G] rs10124604 9 12585186 [A/G] rs10809800 9 12589981 [T/C] rs4428755 9 12593124 [A/C] rs1359442 9 12594030 [A/G] rs10756380 9 12594967 [A/G] rs13283146 9 12599561 [T/C] rs10809802 9 12599803 [T/C] rs1408790 9 12602681 [A/G] rs10960718 9 12606092 [A/G] rs1325116 9 12608432 [T/C] rs7874576 9 12610410 [A/G] rs10809806 9 12611123 [A/G] rs1359444 9 12612897 [A/G] rs12350416 9 12619787 [T/C] rs10738286 9 12619795 [T/G] rs10960723 9 12622878 [A/C] rs1408793 9 12628213 [A/C] rs10124166 9 12637846 [A/G] rs10960736 9 12641987 [T/C] rs2031454 9 12642366 [A/G] rs6474720 9 12643558 [A/G] rs1155509 9 12647332 [T/G] rs9657586 9 12650288 [T/C] rs1408794 9 12651340 [A/G] rs1408795 9 12651413 [T/G] rs996697 9 12652983 [T/C] rs10435754 9 12657603 [T/C] rs2209275 9 12663234 [T/G] rs11787985 9 12663561 [T/C] rs1325127 9 12668328 [T/C] rs9298679 9 12669346 [A/G] rs1041105 9 12671059 [T/C] rs1408798 9 12671856 [T/C] rs1408799 9 12672097 [T/C] rs1408801 9 12672320 [A/G] rs16929340 9 12674124 [T/C] rs10960751 9 12675264 [T/C] rs7847593 9 12683639 [A/C] rs11791497 9 12687872 [A/C] rs2762458 9 12692280 [A/G] rs2075508 9 12698363 [T/C] NM_000550 TYRP1 Silent rs2762462 9 12699776 [T/C] NM_000550 TYRP1 Silent rs2209277 9 12706236 [T/C] NM_000550,NR_125775 TYRP1,LURAP1L-AS1 Silent,Silent rs2209278 9 12706652 [T/C] NM_000550,NR_125775 TYRP1,LURAP1L-AS1 Silent,Silent rs10960756 9 12707206 [A/G] NM_000550,NR_125775 TYRP1,LURAP1L-AS1 Silent,Silent rs10809828 9 12707861 [A/G] NM_000550,NR_125775 TYRP1,LURAP1L-AS1 Silent,Silent rs683 9 12709305 [A/C] NM_000550,NR_125775 TYRP1,LURAP1L-AS1 EXON Silent,Silent rs910 9 12710035 [A/C] NM_000550,NR_125775 TYRP1,LURAP1L-AS1 EXON Silent,Silent rs1063380 9 12710090 [T/C] NM_000550,NR_125775 TYRP1,LURAP1L-AS1 EXON Silent,Silent rs1137134 9 12712157 [A/G] NR_125775 LURAP1L-AS1 Silent rs3891858 9 12716172 [A/G] NR_125775 LURAP1L-AS1 Silent rs7871257 9 12722357 [A/G] NR_125775 LURAP1L-AS1 Silent rs7025758 9 12730636 [A/C] NR_125775 LURAP1L-AS1 Silent rs2382364 9 12734504 [A/C] NR_125775 LURAP1L-AS1 Silent rs970946 9 12738690 [A/C] NR_125775 LURAP1L-AS1 Silent rs7019486 9 12748633 [T/C] NR_125775 LURAP1L-AS1 Silent rs10125771 9 12757058 [A/G] NR_125775 LURAP1L-AS1 Silent rs10960779 9 12758881 [A/G] NR_125775 LURAP1L-AS1 Silent rs10809837 9 12759352 [T/C] NR_125775 LURAP1L-AS1 Silent rs1041174 9 12763001 [T/G] NR_125775 LURAP1L-AS1 Silent rs10960783 9 12763809 [A/G] NR_125775 LURAP1L-AS1 Silent rs10119113 9 12765117 [T/G] NR_125775 LURAP1L-AS1 Silent rs1326795 9 12770108 [T/C] NR_125775 LURAP1L-AS1 Silent rs1887175 9 12770868 [A/C] NR_125775 LURAP1L-AS1 Silent rs1887177 9 12771222 [T/G] NR_125775 LURAP1L-AS1 Silent rs7855624 9 12773263 [A/C] NR_125775 LURAP1L-AS1 Silent rs1326796 9 12774019 [T/C] NR_125775 LURAP1L-AS1 Silent rs3750502 9 12776516 [A/C] NR_125775,NM_203403 LURAP1L-AS1,LURAP1L Silent,Silent rs3750503 9 12776630 [T/C] NR_125775,NM_203403 LURAP1L-AS1,LURAP1L Silent,Silent rs1326800 9 12778224 [T/C] NR_125775,NM_203403 LURAP1L-AS1,LURAP1L Silent,Silent rs16929519 9 12778271 [T/C] NR_125775,NM_203403 LURAP1L-AS1,LURAP1L Silent,Silent rs10809843 9 12780670 [T/C] NR_125775,NM_203403 LURAP1L-AS1,LURAP1L Silent,Silent rs7042370 9 12785073 [T/C] NR_125775,NM_203403 LURAP1L-AS1,LURAP1L Silent,Silent rs7029119 9 12791031 [T/C] NR_125775,NM_203403 LURAP1L-AS1,LURAP1L Silent,Silent rs1887174 9 12794833 [A/G] NR_125775,NM_203403 LURAP1L-AS1,LURAP1L Silent,Silent rs1041177 9 12795698 [T/C] NR_125775,NM_203403 LURAP1L-AS1,LURAP1L Silent,Silent rs16929574 9 12796718 [T/C] NR_125775,NM_203403 LURAP1L-AS1,LURAP1L Silent,Silent rs9298684 9 12801148 [A/G] NR_125775,NM_203403 LURAP1L-AS1,LURAP1L Silent,Silent rs4111024 9 12813037 [A/C] NR_125775,NM_203403 LURAP1L-AS1,LURAP1L Silent,Silent rs6474732 9 12815091 [A/C] NM_203403 LURAP1L Silent rs16929608 9 12816521 [A/C] NM_203403 LURAP1L Silent rs6474734 9 12818455 [T/G] NM_203403 LURAP1L Silent rs7846724 9 12818692 [A/G] NM_203403 LURAP1L Silent rs16929629 9 12822458 [A/G] NM_203403 LURAP1L EXON Silent rs17285931 9 12822487 [T/C] NM_203403 LURAP1L EXON Silent rs16929630 9 12822678 [T/C] NM_203403 LURAP1L EXON Silent rs10809848 9 12829714 [T/C] rs617572 9 12830070 [A/G] rs16929654 9 12837082 [A/G] rs652278 9 12839484 [T/C] rs10960816 9 12842241 [T/C] rs495637 9 12842366 [T/G] rs620255 9 12844891 [T/C] rs16923061 9 12846053 [A/G] rs483855 9 12846491 [T/C] rs645121 9 12852488 [T/G] rs13297189 9 12853276 [A/G] rs7868380 9 12855260 [T/C] rs662135 9 12856773 [T/C] rs4406510 9 12860574 [T/C] rs13291898 9 12861280 [A/C] rs7030039 9 12870440 [T/C] rs637582 9 12874703 [T/C] rs558579 9 12875204 [A/G] rs6474741 9 12886899 [A/C] rs1929918 9 12890233 [T/C] rs2183864 9 12897342 [A/G] rs7032650 9 12899790 [A/G] rs1332083 9 12900789 [T/C] rs1332085 9 12904223 [T/C] rs10960828 9 12905153 [A/C] rs10435758 9 12906962 [T/G] rs13292327 9 12907048 [A/G] rs13293601 9 12907902 [A/C] rs10809858 9 12908303 [A/G] rs10756424 9 12908447 [T/G] rs1332053 9 12910124 [A/G] rs10448182 9 12910295 [T/C] rs10960834 9 12913298 [T/G] rs10809860 9 12914345 [A/C] rs1984050 9 12917048 [T/G] rs10125252 9 12920004 [A/G] rs1888859 9 12921644 [T/G] rs2065423 9 12922330 [A/G] rs10511575 9 12924111 [A/G] rs7020025 9 12924582 [A/G] rs7020076 9 12924863 [A/G] rs10511576 9 12925921 [A/G] rs1412294 9 12926360 [T/G] rs1412296 9 12926571 [T/G] rs1332057 9 12928475 [A/G] rs16929942 9 12931403 [A/G] rs10960847 9 12942956 [T/C] rs4740537 9 12954308 [T/C] rs10809863 9 12956312 [A/G] rs10448183 9 12957884 [A/G] rs10809865 9 12959188 [T/C] rs4741264 9 12960088 [T/C] rs1536791 9 12971966 [A/G] rs1536792 9 12972382 [A/G] rs13289590 9 12982583 [T/C] rs10491615 9 12984009 [T/G] rs1412301 9 12985487 [T/C] rs1332071 9 12988126 [A/G] rs1887884 9 12995112 [T/C] rs12000151 9 13001691 [A/G] rs1360517 9 13007129 [T/C] rs1332074 9 13011270 [A/G] rs10756439 9 13014232 [A/G] rs12351740 9 13020010 [T/C] rs10514822 9 13025284 [T/G] rs10809876 9 13027530 [A/G] rs4741270 9 13028726 [T/C] rs9792560 9 13029816 [A/G] rs7848632 9 13030676 [A/C] rs7029019 9 13032490 [A/C] rs10435759 9 13033268 [T/C] rs17542206 9 13044407 [T/G] rs10960908 9 13046042 [A/C] rs1360059 9 13048141 [A/C] rs12352060 9 13050957 [T/C] rs10960916 9 13052570 [A/G] rs4741277 9 13055896 [T/G] rs1328900 9 13063205 [A/G] rs7861153 9 13063892 [A/G] rs999648 9 13064793 [T/C] rs10809894 9 13071072 [T/C] rs10960928 9 13077072 [A/G] rs10738320 9 13088211 [A/G] rs12346832 9 13092076 [T/C] rs10960942 9 13093345 [A/G] rs10756449 9 13095872 [T/C] rs10514824 9 13099797 [A/G] rs10733253 9 13105638 [T/C] rs722651 9 13106335 [A/G] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ EXON Silent,Silent,Silent,Silent rs3264 9 13106598 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ EXON Silent,Silent,Silent,Silent rs10217351 9 13107679 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs7871226 9 13108231 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs3765550 9 13108794 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs2274647 9 13115422 [T/G] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs10960954 9 13120380 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs9886797 9 13124767 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs10809906 9 13133479 [A/G] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs10809911 9 13147764 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs10756457 9 13150531 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ EXON Synonymous_K1203K,Synonymous_K1203K,Synonymous_K1203K,Synonymous_K1203K rs1331670 9 13158958 [A/G] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs2225483 9 13164434 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs12351444 9 13171410 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs1999394 9 13171466 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs1331673 9 13171577 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs2274856 9 13176312 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ EXON Synonymous_S918S,Synonymous_S918S,Synonymous_S918S,Synonymous_S918S rs1331675 9 13177389 [A/G] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs10756461 9 13185149 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs4741289 9 13190163 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ EXON Missense_E702K,Missense_E702K,Missense_E702K,Missense_E702K rs10809915 9 13209807 [A/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs17273416 9 13214871 [A/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs1412112 9 13217885 [T/G] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs11790910 9 13221628 [A/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs17273542 9 13224491 [A/G] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ EXON Missense_S92L,Missense_S92L,Missense_S92L,Missense_S92L rs7875612 9 13251770 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs11793993 9 13265893 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs10809923 9 13267800 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs10809924 9 13269740 [T/C] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs1330136 9 13273293 [A/G] NM_003829,NM_001261407,NM_001261406,NM_001330637 MPDZ,MPDZ,MPDZ,MPDZ Silent,Silent,Silent,Silent rs10961005 9 13282447 [A/G] rs10809933 9 13300367 [A/G] rs13439896 9 13300442 [A/G] rs13291386 9 13315466 [A/G] rs7036858 9 13317775 [T/C] rs10756472 9 13319020 [T/C] rs12001862 9 13319122 [T/C] rs1038978 9 13323468 [A/G] rs7032201 9 13330233 [T/C] rs11794329 9 13345642 [A/C] rs10961028 9 13348599 [T/C] rs1169239 9 13350478 [T/C] rs1147779 9 13352297 [A/G] rs1147782 9 13352941 [A/G] rs1811647 9 13354300 [T/C] rs1186041 9 13357550 [A/G] rs10511579 9 13362974 [A/G] rs1169237 9 13364677 [A/G] rs7038474 9 13365816 [A/G] rs12341870 9 13375758 [A/G] rs928174 9 13380289 [A/C] rs928175 9 13380507 [T/C] rs10114398 9 13383165 [T/G] rs7045869 9 13388038 [T/C] rs10961039 9 13396958 [T/C] rs12339589 9 13398587 [A/G] rs7027951 9 13405961 [A/C] rs10809945 9 13413469 [A/G] NR_033863 LINC01235 Silent rs12000439 9 13422337 [T/C] NR_033863 LINC01235 Silent rs16930323 9 13440728 [T/C] rs10491751 9 13444932 [A/G] rs12336696 9 13450490 [T/C] rs2184230 9 13451243 [A/G] rs1556577 9 13453984 [T/G] rs966701 9 13457640 [T/G] rs4740551 9 13458523 [A/G] rs10756475 9 13466310 [T/C] rs12238169 9 13466329 [T/G] rs983618 9 13467026 [T/G] rs10809954 9 13468616 [A/G] rs12237974 9 13469565 [T/G] rs2182906 9 13469705 [A/G] rs10961084 9 13485035 [A/G] rs2890969 9 13491120 [A/G] rs1889297 9 13492623 [T/C] rs10961091 9 13498835 [T/C] rs10738335 9 13503997 [T/C] rs1333996 9 13504924 [T/C] rs10809958 9 13507764 [A/G] rs3737150 9 13508282 [A/G] rs12684544 9 13510394 [T/G] rs4741307 9 13511067 [T/C] rs1543713 9 13520190 [A/G] rs10961109 9 13526525 [T/G] rs10961110 9 13528833 [A/G] rs933034 9 13530711 [A/G] rs974350 9 13531732 [T/C] rs2018555 9 13532846 [A/C] rs7039074 9 13536161 [T/C] rs874867 9 13536352 [A/G] rs12004672 9 13539278 [A/G] rs7855886 9 13542480 [T/G] rs1333989 9 13546652 [T/G] rs10491754 9 13548060 [A/C] rs7042381 9 13549596 [T/C] rs10961135 9 13553285 [T/C] rs11999938 9 13555912 [T/G] rs7018619 9 13556275 [T/C] rs10491757 9 13560266 [A/G] rs10961141 9 13560795 [A/G] rs10491758 9 13564273 [T/C] rs10961147 9 13565582 [T/G] rs1324186 9 13568063 [T/C] rs10756482 9 13571341 [T/C] rs9969775 9 13571933 [A/C] rs7847125 9 13577494 [T/C] rs7864760 9 13578387 [A/G] rs7018881 9 13586599 [T/C] rs10961156 9 13590418 [A/G] rs10756485 9 13590443 [T/C] rs10961157 9 13590687 [T/C] rs13299116 9 13591906 [T/C] rs1029139 9 13592377 [T/C] rs10123222 9 13592766 [A/G] rs10123240 9 13592808 [A/G] rs10123887 9 13593125 [A/G] rs1408320 9 13598413 [T/C] rs1590408 9 13600898 [T/C] rs10961165 9 13602338 [T/C] rs10961168 9 13603327 [A/G] rs10809998 9 13606721 [T/C] rs12336782 9 13609119 [T/C] rs1359253 9 13609898 [T/G] rs4278236 9 13609910 [T/C] rs10738339 9 13610778 [T/C] rs1324192 9 13612345 [A/G] rs7019262 9 13614384 [A/G] rs16930557 9 13614760 [T/C] rs10217675 9 13615461 [T/G] rs2382402 9 13616003 [T/C] rs1324193 9 13616063 [A/C] rs1535836 9 13616431 [A/G] rs10810000 9 13617635 [T/C] rs12006531 9 13618021 [A/G] rs12341613 9 13619784 [T/C] rs10961177 9 13621142 [A/G] rs1853609 9 13630162 [T/C] rs13440249 9 13631992 [A/G] rs12352645 9 13635181 [A/G] rs16930601 9 13639416 [A/G] rs16930619 9 13647404 [T/G] rs10810001 9 13648463 [T/C] rs12002470 9 13653594 [A/G] rs10961187 9 13657571 [A/G] rs8192964 9 13660128 [T/G] rs8192966 9 13660943 [T/C] rs642806 9 13671296 [A/G] rs7872836 9 13673697 [A/G] rs571485 9 13674291 [T/G] rs8192978 9 13675500 [A/C] rs688703 9 13677557 [A/G] rs613444 9 13682827 [A/G] rs522594 9 13682981 [A/G] rs16930712 9 13686028 [T/C] rs4740554 9 13688437 [A/C] rs518054 9 13689066 [T/G] rs571221 9 13690235 [T/C] rs1590404 9 13697152 [A/C] rs562328 9 13703826 [T/C] rs1998584 9 13704539 [T/C] rs1324171 9 13705584 [T/G] rs626778 9 13705679 [A/C] rs992457 9 13705882 [T/C] rs612828 9 13706483 [A/G] rs610593 9 13706973 [T/C] rs524126 9 13708607 [T/C] rs504659 9 13711595 [T/C] rs10120807 9 13730047 [A/G] rs4741325 9 13730340 [T/G] rs979203 9 13730665 [A/G] rs12339356 9 13732363 [T/C] rs2382407 9 13734430 [T/C] rs1556491 9 13736662 [T/C] rs717605 9 13736965 [T/G] rs7040897 9 13737420 [A/C] rs4741326 9 13737975 [A/C] rs10810012 9 13738362 [A/G] rs969544 9 13741905 [A/G] rs11792535 9 13743830 [A/G] rs1887456 9 13744658 [T/G] rs10961216 9 13745502 [A/G] rs10810013 9 13746595 [A/C] rs930543 9 13749977 [A/G] rs10738341 9 13751127 [A/G] rs12347123 9 13759474 [T/G] rs10756494 9 13759929 [A/C] rs10961227 9 13762898 [A/G] rs10756497 9 13763734 [T/C] rs966992 9 13765292 [T/C] rs10810025 9 13765759 [T/C] rs10961229 9 13768750 [T/C] rs1034167 9 13770466 [A/G] rs1034164 9 13771744 [A/G] rs10756500 9 13772055 [A/G] rs1562045 9 13774329 [A/G] rs1359848 9 13774683 [T/C] rs10810029 9 13775193 [T/C] rs7030346 9 13777299 [T/C] rs10756504 9 13779856 [T/C] rs10756505 9 13780058 [T/C] rs10810035 9 13787648 [A/G] rs10756511 9 13790202 [T/C] rs1854163 9 13791531 [A/G] rs7858704 9 13798727 [T/C] rs10961259 9 13799421 [A/G] rs10756514 9 13799717 [T/C] rs1610343 9 13802044 [T/G] rs1410035 9 13803088 [T/C] rs4741336 9 13806091 [T/C] rs2120390 9 13807633 [T/C] rs894822 9 13809735 [A/G] rs987416 9 13812037 [T/G] rs7866165 9 13812685 [T/G] rs986974 9 13815721 [T/C] rs966480 9 13824130 [A/G] rs11788150 9 13825565 [A/C] rs2078639 9 13828594 [T/C] rs17818373 9 13829452 [T/C] rs1410040 9 13830766 [A/G] rs726353 9 13832491 [T/G] rs9407545 9 13832587 [T/C] rs17219480 9 13836332 [T/C] rs10961271 9 13839436 [A/C] rs12003992 9 13844771 [A/G] rs10491766 9 13846800 [T/C] rs7019634 9 13848797 [T/C] rs16930965 9 13851118 [A/G] rs9407554 9 13851999 [A/G] rs10961283 9 13852782 [A/G] rs7036600 9 13854370 [A/C] rs12237041 9 13854965 [A/C] rs13295592 9 13856937 [T/C] rs17221355 9 13857272 [T/C] rs13300184 9 13857339 [T/C] rs16931028 9 13857405 [A/G] rs16931031 9 13857580 [A/G] rs12341720 9 13859052 [T/C] rs7028624 9 13859987 [A/G] rs16931045 9 13861427 [T/G] rs10117920 9 13864265 [A/G] rs12341611 9 13864770 [T/C] rs7858214 9 13865260 [T/C] rs2224553 9 13867306 [T/C] rs10810049 9 13868750 [T/G] rs12006148 9 13871187 [A/G] rs12004949 9 13872331 [T/C] rs2382423 9 13873487 [T/G] rs10961291 9 13876562 [A/G] rs953747 9 13876844 [T/G] rs12344958 9 13879572 [A/C] rs9407563 9 13879604 [A/G] rs7036035 9 13880787 [T/C] rs1576066 9 13887476 [T/C] rs9969743 9 13891525 [T/C] rs1831087 9 13892287 [T/C] rs7034760 9 13896279 [A/G] rs13292371 9 13898481 [A/C] rs10121526 9 13898615 [A/G] rs1923352 9 13898956 [A/G] rs10217667 9 13902048 [T/C] rs10961296 9 13904860 [A/G] rs16931104 9 13908368 [T/C] rs16931115 9 13911893 [A/G] rs12335400 9 13912195 [A/G] rs10113975 9 13912482 [A/C] rs1969938 9 13917482 [T/C] rs16931122 9 13919229 [T/C] rs10961300 9 13921272 [T/G] rs16931137 9 13921556 [A/G] rs7850903 9 13921788 [T/C] rs10961303 9 13926247 [A/G] rs2382427 9 13928028 [T/C] NR_038194 LINC00583 EXON Silent rs10123937 9 13929064 [A/G] NR_038194 LINC00583 Silent rs10117560 9 13930857 [T/C] NR_038194 LINC00583 Silent rs17277138 9 13933371 [A/C] NR_038194 LINC00583 Silent rs16931157 9 13937099 [T/C] NR_038194 LINC00583 Silent rs13285663 9 13937519 [A/G] NR_038194 LINC00583 Silent rs16931161 9 13943319 [A/G] NR_038194 LINC00583 Silent rs17277593 9 13950593 [A/G] rs16931165 9 13953898 [T/G] rs13290672 9 13959282 [T/C] rs12335962 9 13960309 [T/G] rs7856131 9 13961462 [T/C] rs7855714 9 13968369 [T/C] rs7869403 9 13968491 [A/G] rs1590263 9 13970315 [A/G] rs16923127 9 13974077 [T/C] rs1609801 9 13974667 [T/C] rs7037099 9 13979872 [A/C] rs7048074 9 13980085 [T/C] rs10810064 9 13982131 [A/C] rs7870444 9 13986066 [T/C] rs755267 9 13986757 [T/C] rs16931196 9 13988925 [T/C] rs7025591 9 13989084 [A/C] rs10810073 9 13992283 [T/C] rs1322130 9 14003679 [T/C] rs12005778 9 14004053 [T/C] rs7018490 9 14005103 [A/C] rs7019866 9 14005900 [A/G] rs2181073 9 14010270 [T/C] rs10961326 9 14010321 [T/C] rs10961329 9 14012093 [A/G] rs16931224 9 14012301 [A/G] rs7848517 9 14012596 [T/C] rs7039809 9 14013955 [A/G] rs12001724 9 14014614 [T/G] rs7857245 9 14014968 [T/C] rs16931233 9 14016560 [T/G] rs1853195 9 14020982 [T/G] rs16931250 9 14021767 [A/G] rs1977235 9 14021990 [A/G] rs12351326 9 14023577 [A/G] rs7022407 9 14025101 [T/C] rs12550926 9 14025508 [A/C] rs10810080 9 14026089 [T/C] rs16931256 9 14026510 [A/C] rs16931261 9 14028713 [A/G] rs6474805 9 14029188 [A/C] rs10961344 9 14030100 [A/G] rs10961346 9 14030444 [A/G] rs10810082 9 14030829 [A/C] rs10961347 9 14031216 [T/C] rs3899674 9 14032023 [A/G] rs3920568 9 14036242 [A/G] rs10810084 9 14036271 [T/C] rs1853197 9 14037831 [A/C] rs10756524 9 14043162 [A/C] rs16931284 9 14043253 [A/C] rs10756525 9 14044604 [T/C] rs10756526 9 14045245 [T/G] rs7874668 9 14045745 [A/G] rs10961355 9 14045800 [T/C] rs9792570 9 14056264 [A/G] rs7872771 9 14057173 [A/G] rs1156572 9 14058402 [A/G] rs10116586 9 14058548 [A/C] rs1407345 9 14063510 [A/G] rs506325 9 14063719 [T/C] rs7039300 9 14064741 [T/G] rs10283831 9 14064891 [T/C] rs564854 9 14065522 [A/C] rs512477 9 14067281 [A/G] rs10961361 9 14070422 [A/G] rs569114 9 14072370 [A/G] rs516325 9 14074022 [T/C] rs10961364 9 14074099 [T/G] rs16931322 9 14078878 [A/G] rs480700 9 14079067 [T/C] rs484555 9 14085583 [A/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB EXON Silent,Silent,Silent,Silent rs7858 9 14087769 [T/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB EXON Silent,Silent,Silent,Silent rs548824 9 14088789 [T/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs7863561 9 14090542 [A/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs542733 9 14098867 [T/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs508940 9 14107096 [T/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs510970 9 14109456 [T/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs571693 9 14110242 [T/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs573057 9 14113903 [A/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs498010 9 14116484 [T/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs580501 9 14117221 [A/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs10810092 9 14119583 [A/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs2307079 9 14120803 [T/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs7031859 9 14124696 [A/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs7032297 9 14124748 [A/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs10114939 9 14135399 [T/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs3780582 9 14136495 [T/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs2382437 9 14139828 [T/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs7042365 9 14144821 [A/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs7031735 9 14145487 [T/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs10756531 9 14152436 [A/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs723968 9 14154231 [T/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs10810096 9 14154697 [T/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs7863447 9 14155418 [A/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs7044402 9 14157468 [A/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs2382443 9 14159460 [T/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs10810099 9 14161927 [A/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs10961399 9 14164250 [T/C] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs12377502 9 14171645 [A/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs6474821 9 14172048 [A/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs10810102 9 14180401 [A/G] NM_005596,NM_001282787,NM_001190737,NM_001190738 NFIB,NFIB,NFIB,NFIB Silent,Silent,Silent,Silent rs2890982 9 14181653 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs16931436 9 14185939 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs4375095 9 14187523 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs2382451 9 14189188 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10756538 9 14194856 [T/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs2382454 9 14196340 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10738355 9 14197498 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10810110 9 14199422 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10810113 9 14200005 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs12551619 9 14205169 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs12339675 9 14206835 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10961424 9 14208724 [A/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs12340584 9 14210653 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10961426 9 14211843 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs12682686 9 14213974 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10511593 9 14215878 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs7048086 9 14219691 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs2382444 9 14221591 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10810119 9 14226139 [A/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10961436 9 14229179 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10961439 9 14233159 [T/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10961440 9 14234315 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs7040053 9 14235002 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10961441 9 14236134 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10756542 9 14237649 [A/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs1322985 9 14238793 [A/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs1555553 9 14241817 [T/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10810120 9 14244376 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs1322986 9 14244413 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs7030457 9 14245551 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10961450 9 14247488 [A/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs7866589 9 14247788 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs7027899 9 14248934 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs7874591 9 14249488 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs3761668 9 14250285 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10435726 9 14251917 [T/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs4740564 9 14260684 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs1322990 9 14262699 [T/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10122910 9 14264717 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs7846889 9 14267601 [T/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10961455 9 14269256 [A/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs1061820 9 14269556 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs1322991 9 14270342 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs1033837 9 14274950 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs4740567 9 14281896 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs6474827 9 14286126 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10738358 9 14286997 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10810124 9 14290978 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10810126 9 14292207 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10124289 9 14292640 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10961466 9 14292880 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs12685327 9 14293115 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10810127 9 14294350 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs17213362 9 14294980 [T/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10429540 9 14297978 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs11999144 9 14300901 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs2382468 9 14303061 [T/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs7021322 9 14303488 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10810130 9 14304973 [A/T] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs17213755 9 14309552 [A/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10810131 9 14310504 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs10961473 9 14312724 [T/C] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB Silent,Silent,Silent rs2273933 9 14313712 [T/G] NM_005596,NM_001190737,NM_001190738 NFIB,NFIB,NFIB EXON Silent,Silent,Silent rs7874736 9 14316570 [A/G] NM_001190738 NFIB Silent rs7040685 9 14323346 [T/G] NM_001190738 NFIB Silent rs7048960 9 14334138 [T/C] NM_001190738 NFIB Silent rs10810132 9 14338470 [A/C] NM_001190738 NFIB Silent rs13295646 9 14342890 [A/G] NM_001190738 NFIB Silent rs598296 9 14343670 [T/C] NM_001190738 NFIB Silent rs2025318 9 14346131 [T/G] NM_001190738 NFIB Silent rs877571 9 14347811 [A/C] NM_001190738 NFIB Silent rs877569 9 14348563 [A/G] NM_001190738 NFIB Silent rs13289800 9 14348827 [A/G] NM_001190738 NFIB Silent rs13290272 9 14350469 [T/C] NM_001190738 NFIB Silent rs10961483 9 14352457 [A/G] NM_001190738 NFIB Silent rs7864996 9 14356795 [A/C] NM_001190738 NFIB Silent rs13296301 9 14358681 [T/G] NM_001190738 NFIB Silent rs12379369 9 14359000 [T/C] NM_001190738 NFIB Silent rs10756546 9 14364590 [T/C] NM_001190738 NFIB Silent rs683474 9 14365269 [T/C] NM_001190738 NFIB Silent rs2021306 9 14365307 [A/G] NM_001190738 NFIB Silent rs471088 9 14367505 [A/G] NM_001190738 NFIB Silent rs10961490 9 14370172 [T/C] NM_001190738 NFIB Silent rs4741365 9 14376009 [A/G] NM_001190738 NFIB Silent rs4741366 9 14376038 [T/C] NM_001190738 NFIB Silent rs2382469 9 14378712 [A/C] NM_001190738 NFIB Silent rs509609 9 14378776 [A/G] NM_001190738 NFIB Silent rs1108676 9 14379104 [A/C] NM_001190738 NFIB Silent rs568008 9 14380528 [T/C] NM_001190738 NFIB Silent rs630973 9 14380945 [T/G] NM_001190738 NFIB Silent rs7867427 9 14383296 [T/C] NM_001190738 NFIB Silent rs17708974 9 14383316 [A/C] NM_001190738 NFIB Silent rs679613 9 14384950 [A/G] NM_001190738 NFIB Silent rs10810134 9 14384976 [A/G] NM_001190738 NFIB Silent rs2382470 9 14387817 [A/G] NM_001190738 NFIB Silent rs717932 9 14389011 [T/C] NM_001190738 NFIB Silent rs2382474 9 14391869 [T/G] NM_001190738 NFIB Silent rs2208919 9 14392785 [T/C] NM_001190738 NFIB Silent rs10810136 9 14393854 [A/G] NM_001190738 NFIB Silent rs6474832 9 14394325 [T/C] NM_001190738 NFIB Silent rs2076872 9 14395035 [A/G] NM_001190738 NFIB Silent rs1807429 9 14395595 [T/G] NM_001190738 NFIB Silent rs10481545 9 14396833 [T/C] NM_001190738 NFIB Silent rs10810137 9 14398201 [T/C] NM_001190738 NFIB Silent rs17709614 9 14401281 [T/C] rs1323349 9 14401932 [A/C] rs7873382 9 14402446 [T/C] rs7042750 9 14405158 [T/C] rs1323350 9 14405297 [T/C] rs11788403 9 14405555 [T/G] rs1570499 9 14405801 [A/C] rs10961505 9 14410591 [T/C] rs4740570 9 14411546 [T/C] rs4741374 9 14412287 [T/C] rs10756549 9 14419053 [T/C] rs10810142 9 14419092 [T/C] rs10738360 9 14419894 [T/C] rs7875762 9 14422035 [A/G] rs2025319 9 14422868 [A/G] rs2031195 9 14424929 [A/G] rs1028704 9 14426289 [A/C] rs990938 9 14427560 [T/C] rs990937 9 14427727 [A/G] rs4741377 9 14429307 [T/C] rs373034 9 14430286 [A/G] rs303737 9 14430328 [T/C] rs991115 9 14432097 [T/C] rs501360 9 14433910 [A/G] rs958957 9 14434284 [A/G] rs508259 9 14437476 [T/C] rs303733 9 14437943 [A/G] rs303727 9 14440552 [A/G] rs215498 9 14440739 [T/G] rs1323351 9 14442265 [T/C] rs551112 9 14443468 [A/C] rs10491775 9 14443784 [A/C] rs1323339 9 14444316 [T/G] rs1556032 9 14446001 [T/C] rs567977 9 14447233 [T/C] rs10810148 9 14447766 [A/G] rs535076 9 14448497 [T/C] rs10810150 9 14452729 [T/C] rs17761983 9 14453076 [A/C] rs7021022 9 14456012 [T/C] rs4741378 9 14456738 [A/G] rs527093 9 14457263 [T/C] rs6474837 9 14460872 [T/C] rs913416 9 14464744 [T/C] rs913412 9 14465710 [A/G] rs877451 9 14465961 [T/G] rs303724 9 14468137 [A/G] rs1998495 9 14468321 [T/C] rs303723 9 14469146 [A/G] rs16931824 9 14469419 [T/C] rs516641 9 14470759 [T/C] rs10961534 9 14470833 [A/G] rs10491773 9 14472090 [A/G] rs1323344 9 14473378 [T/G] rs303721 9 14473556 [T/C] rs501463 9 14475352 [T/C] rs4141905 9 14478588 [T/C] rs487674 9 14479228 [A/C] rs186228 9 14479361 [T/C] rs392125 9 14480141 [T/C] rs16931840 9 14488950 [A/G] rs439269 9 14491347 [T/C] rs10961542 9 14493251 [T/C] rs1323348 9 14494388 [T/C] rs7875078 9 14494845 [A/C] rs4741384 9 14496808 [T/C] rs191006 9 14498336 [T/C] rs7852071 9 14508360 [A/G] rs7023433 9 14511645 [A/C] rs4741388 9 14514366 [T/C] rs1318729 9 14515364 [T/C] rs4741389 9 14517555 [T/C] rs10756570 9 14518646 [T/C] rs873553 9 14518829 [A/C] rs7851867 9 14518985 [A/G] rs1106726 9 14519301 [T/C] rs13288173 9 14520560 [T/C] rs913417 9 14520611 [A/G] rs1328003 9 14523803 [T/C] rs927969 9 14524438 [A/C] rs16931893 9 14524741 [T/C] rs4741390 9 14524784 [A/G] rs913418 9 14525980 [T/C] rs10961553 9 14527083 [T/G] rs10810172 9 14529623 [T/C] rs12376530 9 14529836 [A/C] rs7042232 9 14533251 [A/G] rs6474842 9 14533865 [T/C] rs7046317 9 14534103 [A/G] rs10756571 9 14534505 [T/C] rs1556028 9 14534704 [T/C] rs7020007 9 14535343 [T/C] rs10810175 9 14535957 [A/G] rs12379841 9 14536315 [A/G] rs2039051 9 14536379 [T/C] rs10961558 9 14538577 [A/G] rs10961560 9 14539758 [A/G] rs4741397 9 14540362 [A/G] rs7847421 9 14540539 [A/G] rs7847342 9 14540625 [A/C] rs7847828 9 14540818 [A/G] rs7850989 9 14541236 [T/C] rs16931920 9 14543181 [A/C] rs11789001 9 14543216 [T/C] rs927971 9 14543548 [T/C] rs2149104 9 14544555 [A/G] rs7850284 9 14544731 [T/C] rs10810178 9 14547556 [T/C] rs12002454 9 14547633 [T/C] rs3736996 9 14548852 [T/C] rs10491772 9 14550138 [A/G] rs1536647 9 14552292 [T/G] rs7047109 9 14555896 [T/C] rs10756576 9 14556659 [A/G] rs10961571 9 14557806 [T/C] rs16931972 9 14557911 [T/C] rs4741405 9 14560916 [T/C] rs1556029 9 14562630 [T/C] rs10961578 9 14563533 [A/C] rs10491771 9 14564090 [T/C] rs717329 9 14564976 [T/C] rs10961582 9 14565982 [A/C] rs7867360 9 14566116 [T/C] rs7040652 9 14566406 [T/G] rs16932018 9 14567981 [A/C] rs12352208 9 14573137 [A/G] rs10116154 9 14573613 [T/C] rs7029906 9 14585052 [T/G] rs12238310 9 14588049 [T/C] rs10961601 9 14589694 [T/C] rs7857143 9 14590805 [T/C] rs2225163 9 14592180 [A/C] rs10756583 9 14594350 [T/C] rs11794863 9 14594501 [T/G] rs11793843 9 14596263 [T/C] rs4741409 9 14604569 [T/G] rs7850166 9 14604822 [T/C] rs4741410 9 14605043 [T/C] rs12337747 9 14606281 [T/G] rs1343705 9 14610866 [A/G] rs10810184 9 14613104 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10738372 9 14615350 [T/C] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12236525 9 14616590 [T/C] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10961620 9 14616757 [T/C] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7044386 9 14616829 [T/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10810186 9 14617069 [T/C] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3802482 9 14618856 [T/C] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10961621 9 14620540 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7874535 9 14622952 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12005035 9 14624243 [A/C] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7873022 9 14625979 [T/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10120588 9 14645813 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7849273 9 14648118 [T/C] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10961636 9 14649728 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7851730 9 14650684 [T/C] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11790280 9 14651283 [T/C] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10119411 9 14656681 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10756597 9 14657139 [A/C] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16932127 9 14660055 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10481503 9 14660700 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6474850 9 14662459 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10961649 9 14670949 [T/C] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2890992 9 14672267 [T/C] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10810211 9 14676870 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10810212 9 14677538 [T/C] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17216147 9 14678017 [T/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4571826 9 14678115 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10810213 9 14679206 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17288444 9 14686308 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10810220 9 14689088 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10756603 9 14689191 [T/C] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10756604 9 14692676 [A/G] NR_148716,NR_148717,NM_001354120,NR_148715,NR_148718,NM_001354123,NM_001354118,NM_001354124,NM_001354129,NM_001354126,NM_001354119,NM_001354127,NM_001354128,NM_001354130,NM_178566,NM_001354125,NM_001354121,NR_148714,NM_001354122 ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21,ZDHHC21 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2890989 9 14694211 [A/G] rs2382479 9 14694302 [T/C] rs4326470 9 14694536 [A/C] rs1858633 9 14696674 [T/G] rs7021169 9 14701230 [A/C] rs12685826 9 14701616 [A/G] rs7024505 9 14712257 [A/C] rs3819004 9 14720057 [T/C] NM_005454 CER1 EXON Silent rs3747532 9 14722477 [G/C] NM_005454 CER1 EXON Missense_A65G rs10115703 9 14722616 [A/G] NM_005454 CER1 EXON Missense_R19W rs7035643 9 14723637 [T/G] rs10810226 9 14724502 [T/C] rs11794846 9 14726304 [A/G] rs12345917 9 14728730 [A/G] rs1494338 9 14730124 [T/C] rs10511595 9 14730234 [T/C] rs13287172 9 14733642 [A/C] rs1494341 9 14733912 [A/G] rs1048070 9 14735053 [T/C] NM_001177704,NM_144966 FREM1,FREM1 EXON Silent,Silent rs7047712 9 14735187 [T/C] NM_001177704,NM_144966 FREM1,FREM1 EXON Silent,Silent rs10756607 9 14735610 [T/C] NM_001177704,NM_144966 FREM1,FREM1 EXON Silent,Silent rs10961689 9 14737506 [T/G] NM_001177704,NM_144966 FREM1,FREM1 EXON Missense_Q679P,Missense_Q2143P rs8181217 9 14740682 [A/G] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs4124592 9 14746261 [T/G] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs2270529 9 14747133 [T/C] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs4741426 9 14747412 [A/G] NM_001177704,NM_144966 FREM1,FREM1 EXON Synonymous_V489V,Synonymous_V1953V rs10117516 9 14749434 [T/C] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs2890993 9 14751872 [T/G] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs2035987 9 14754010 [A/G] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs10738377 9 14757744 [A/C] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs7864052 9 14757877 [A/C] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs7045154 9 14759725 [A/G] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs13294547 9 14761002 [A/G] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs1724 9 14761226 [T/C] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs10124839 9 14761260 [A/C] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs7858690 9 14761788 [T/C] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs12685742 9 14762700 [T/C] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs16932272 9 14763056 [T/C] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs7039708 9 14763855 [A/G] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs923926 9 14765030 [T/C] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs6474855 9 14767916 [A/G] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs17219005 9 14770658 [T/G] NM_001177704,NM_144966 FREM1,FREM1 EXON Synonymous_I204I,Synonymous_I1668I rs7860370 9 14770825 [T/C] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs954117 9 14771517 [A/G] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs954116 9 14771575 [T/C] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs7849041 9 14771864 [T/C] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs7028801 9 14773370 [A/G] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs6474858 9 14774967 [A/G] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs1874108 9 14775779 [A/G] NM_001177704,NM_144966 FREM1,FREM1 Silent,Silent rs1032474 9 14775853 [A/G] NM_001177704,NM_144966 FREM1,FREM1 EXON Synonymous_D133D,Synonymous_D1597D rs10733289 9 14775859 [A/G] NM_001177704,NM_144966 FREM1,FREM1 EXON Synonymous_A131A,Synonymous_A1595A rs1494354 9 14782497 [T/G] NM_144966 FREM1 Silent rs10961704 9 14782934 [T/C] NM_144966 FREM1 Silent rs12683551 9 14783623 [T/C] NM_144966 FREM1 Silent rs10810239 9 14784665 [A/G] NM_144966 FREM1 Silent rs10810240 9 14784778 [T/G] NM_144966 FREM1 Silent rs7027322 9 14785224 [A/G] NM_144966 FREM1 Silent rs7025956 9 14788407 [T/C] NM_144966 FREM1 Silent rs16932282 9 14788886 [T/C] NM_144966 FREM1 Silent rs10810242 9 14789400 [A/C] NM_144966 FREM1 Silent rs1494348 9 14790363 [T/C] NM_144966 FREM1 Silent rs2291680 9 14791007 [T/C] NM_144966 FREM1 Silent rs12338615 9 14795265 [A/G] NM_144966 FREM1 Silent rs10961709 9 14795358 [A/C] NM_144966 FREM1 Silent rs1908303 9 14797143 [T/G] NM_144966 FREM1 Silent rs9886892 9 14797880 [T/G] NM_144966 FREM1 Silent rs10124784 9 14798176 [A/G] NM_144966 FREM1 Silent rs10738379 9 14800779 [A/C] NM_144966 FREM1 Silent rs10738380 9 14801687 [T/C] NM_144966 FREM1 EXON Synonymous_A1219A rs12350382 9 14802948 [A/G] NM_144966 FREM1 Silent rs17220118 9 14804141 [T/G] NM_144966 FREM1 Silent rs10810248 9 14804733 [T/C] NM_144966 FREM1 Silent rs12683064 9 14806902 [A/G] NM_144966 FREM1 Silent rs12347233 9 14807194 [A/C] NM_144966 FREM1 Silent rs10810251 9 14808325 [T/C] NM_144966 FREM1 Silent rs12347393 9 14810847 [T/G] NM_144966 FREM1 Silent rs7862726 9 14811303 [T/C] NM_144966 FREM1 Silent rs10961726 9 14813976 [T/C] NM_144966 FREM1 Silent rs7023244 9 14819370 [T/G] NM_144966 FREM1 EXON Missense_S803Y rs10961730 9 14819813 [A/C] NM_144966 FREM1 Silent rs2779502 9 14820223 [T/C] NM_144966 FREM1 Silent rs7025001 9 14821333 [T/C] NM_144966 FREM1 Silent rs2779503 9 14821819 [A/G] NM_144966 FREM1 Silent rs1494346 9 14822726 [T/C] NM_144966 FREM1 Silent rs12235714 9 14823221 [T/G] NM_144966 FREM1 EXON Synonymous_G758G rs12236053 9 14824799 [A/G] NM_144966 FREM1 EXON Synonymous_S691S rs2818939 9 14826616 [T/C] NM_144966 FREM1 Silent rs7868862 9 14830821 [T/C] NM_144966 FREM1 Silent rs10810258 9 14830989 [A/G] NM_144966 FREM1 Silent rs2642406 9 14831233 [T/C] NM_144966 FREM1 Silent rs9792613 9 14832349 [T/C] NM_144966 FREM1 Silent rs10961741 9 14832445 [T/C] NM_144966 FREM1 Silent rs10046797 9 14833003 [A/C] NM_144966 FREM1 Silent rs2779508 9 14833488 [A/C] NM_144966 FREM1 Silent rs12555189 9 14834172 [T/G] NM_144966 FREM1 Silent rs1855139 9 14835055 [A/G] NM_144966 FREM1 Silent rs10961746 9 14835081 [A/G] NM_144966 FREM1 Silent rs2779509 9 14838860 [A/G] NM_144966 FREM1 Silent rs1353223 9 14842557 [T/C] NM_144966 FREM1 EXON Missense_I499V rs10810269 9 14844777 [T/C] NM_144966 FREM1 Silent rs2779500 9 14846036 [C/G] NM_144966 FREM1 EXON Missense_V439L rs1021493 9 14848892 [A/G] NM_144966 FREM1 Silent rs12236064 9 14849216 [T/C] NM_144966 FREM1 Silent rs16932354 9 14850256 [T/C] NM_144966 FREM1 Silent rs2779499 9 14850816 [A/G] NM_144966 FREM1 Silent rs2818940 9 14851617 [T/C] NM_144966 FREM1 Silent rs729492 9 14851703 [A/G] NM_144966 FREM1 Silent rs729491 9 14851841 [T/C] NM_144966 FREM1 Silent rs1889053 9 14856284 [T/C] NM_144966 FREM1 Silent rs950739 9 14857740 [T/C] NM_144966 FREM1 EXON Synonymous_R213R rs10511599 9 14858083 [T/C] NM_144966 FREM1 Silent rs1889051 9 14864321 [A/G] NM_144966 FREM1 Silent rs16932379 9 14866251 [A/G] NM_144966 FREM1 Silent rs10116665 9 14866364 [A/G] NM_144966 FREM1 Silent rs16932386 9 14867958 [A/G] NM_144966 FREM1 Silent rs7860346 9 14869179 [A/C] NM_144966 FREM1 EXON Silent rs6474865 9 14869861 [A/G] NM_144966 FREM1 Silent rs10810279 9 14878094 [A/G] NM_144966 FREM1 Silent rs10810280 9 14878376 [A/G] NM_144966 FREM1 Silent rs7862716 9 14880667 [T/C] NM_144966 FREM1 Silent rs10810283 9 14884447 [A/G] NM_144966 FREM1 Silent rs1996893 9 14890268 [T/C] NM_144966 FREM1 Silent rs10810285 9 14891670 [T/C] NM_144966 FREM1 Silent rs10961773 9 14892993 [A/C] NM_144966 FREM1 Silent rs7044651 9 14898142 [T/C] NM_144966 FREM1 Silent rs10961780 9 14898161 [T/G] NM_144966 FREM1 Silent rs10810289 9 14899708 [T/C] NM_144966 FREM1 Silent rs4740593 9 14900356 [T/C] NM_144966 FREM1 Silent rs4741443 9 14900565 [T/C] NM_144966 FREM1 Silent rs1984063 9 14901322 [T/C] NM_144966 FREM1 Silent rs12337423 9 14903275 [T/C] NM_144966 FREM1 Silent rs10961785 9 14903800 [T/C] NM_144966 FREM1 Silent rs940120 9 14906868 [A/G] NM_144966 FREM1 Silent rs7034380 9 14908056 [T/G] NM_144966 FREM1 Silent rs3850442 9 14919539 [A/G] rs1916314 9 14925706 [T/C] rs10961795 9 14929835 [T/G] rs12348103 9 14941672 [T/C] rs3861706 9 14947472 [T/C] rs9969815 9 14949190 [A/G] rs2381973 9 14955988 [T/C] rs6415721 9 14964952 [T/C] rs10961817 9 14982751 [A/G] rs1880013 9 14985047 [A/C] rs10810310 9 14989877 [T/C] rs4548277 9 14993419 [T/G] NR_003920 LOC389705 EXON Silent rs7018678 9 14996243 [A/G] NR_003920 LOC389705 Silent rs1916309 9 15005594 [A/G] NR_003920 LOC389705 Silent rs1403561 9 15011825 [A/G] NR_003920 LOC389705 Silent rs16932518 9 15017840 [T/G] NR_003920 LOC389705 Silent rs4741446 9 15047588 [A/G] rs4445325 9 15055607 [A/G] rs7031476 9 15057624 [A/G] rs7040444 9 15059821 [T/G] rs6474884 9 15060291 [T/C] rs4146765 9 15066819 [T/G] rs4146764 9 15066888 [T/C] rs7849283 9 15067831 [A/G] rs7859597 9 15075185 [A/G] rs10756644 9 15076859 [T/C] rs10961867 9 15078013 [T/G] rs1936718 9 15078522 [A/G] rs10511608 9 15078990 [A/G] rs10961870 9 15079847 [A/G] rs10738386 9 15081438 [T/G] rs16932587 9 15082933 [T/C] rs4741452 9 15084766 [T/C] rs4364728 9 15085796 [A/G] rs10961876 9 15086021 [A/C] rs10124119 9 15086653 [T/C] rs7047010 9 15087382 [T/C] rs4741454 9 15090559 [A/C] rs4741455 9 15091826 [T/C] rs10481554 9 15103918 [A/G] rs7871542 9 15111167 [A/G] rs1780155 9 15115717 [T/C] rs2800605 9 15116228 [A/G] rs2761137 9 15122969 [T/C] rs1323594 9 15124737 [T/G] rs1780160 9 15127943 [T/C] rs1780157 9 15131912 [A/G] rs7860820 9 15133642 [A/G] rs2761112 9 15138120 [A/C] rs1590349 9 15141249 [A/G] rs2800575 9 15145385 [T/G] rs4741469 9 15150372 [T/C] rs7042519 9 15153096 [T/C] rs12551441 9 15153943 [A/G] rs12352518 9 15154363 [T/C] rs2800577 9 15154607 [A/G] rs2096366 9 15157746 [A/C] rs1780159 9 15157977 [T/C] rs9792685 9 15158063 [A/C] rs9298726 9 15159378 [T/C] rs932712 9 15159928 [A/G] rs10961905 9 15169211 [T/C] rs1746331 9 15170552 [T/C] rs971835 9 15175798 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs10738389 9 15179840 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs2761134 9 15186030 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs1407977 9 15188106 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B EXON Missense_I420V,Missense_I407V,Missense_I351V,Missense_I418V,Missense_I255V rs10810360 9 15188743 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs12554907 9 15191599 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs486612 9 15193089 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs7860410 9 15193713 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs10733291 9 15199085 [T/G] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs517928 9 15201410 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs527705 9 15201720 [A/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs693196 9 15202417 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs569078 9 15205014 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs1215177 9 15207485 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs12343442 9 15212216 [T/G] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs472622 9 15215002 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs11791131 9 15216292 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs7870690 9 15218947 [A/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs475957 9 15229622 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs16932848 9 15229766 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs7866474 9 15231634 [T/G] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs591647 9 15235893 [A/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs513270 9 15240033 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs619105 9 15240454 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs12377170 9 15240912 [T/G] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs1215128 9 15243411 [A/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs519664 9 15246652 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339,NM_001168342 TTC39B,TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent,Silent rs10961940 9 15258381 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs7864179 9 15259432 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs10961946 9 15264197 [A/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs7023109 9 15268991 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs10810367 9 15270247 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs9632874 9 15270875 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs7870745 9 15271933 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs16932898 9 15274373 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs7873299 9 15275697 [T/G] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs10122040 9 15279214 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs641579 9 15284100 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs10810368 9 15286744 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs1122677 9 15289941 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs16932948 9 15289986 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs638491 9 15290012 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs7875255 9 15290174 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs7022687 9 15291691 [A/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs585002 9 15293513 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs10114494 9 15295073 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs570474 9 15295505 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs4741484 9 15296119 [A/G] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs11792305 9 15299590 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs583204 9 15299715 [T/G] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs3866794 9 15300116 [T/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs4008004 9 15300968 [A/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs2849049 9 15301428 [A/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs686030 9 15304782 [A/C] NM_152574,NM_001168340,NM_001168341,NM_001168339 TTC39B,TTC39B,TTC39B,TTC39B Silent,Silent,Silent,Silent rs491322 9 15308154 [A/G] rs2245641 9 15309928 [A/C] rs2616752 9 15310704 [T/C] rs682553 9 15319412 [T/C] rs682092 9 15319506 [A/G] rs652185 9 15321542 [A/G] rs12554359 9 15330631 [A/G] rs10124733 9 15333006 [A/G] rs2798748 9 15333788 [T/G] rs688254 9 15335853 [T/C] rs16933006 9 15335914 [A/C] rs10511609 9 15335996 [A/G] rs12554331 9 15337857 [A/G] rs540457 9 15337952 [A/C] rs10961970 9 15339722 [A/G] rs10756657 9 15340686 [T/C] rs518519 9 15342231 [A/C] rs1215129 9 15343613 [A/G] rs498404 9 15347022 [T/G] rs1215134 9 15347518 [T/C] rs1215125 9 15349196 [T/C] rs473315 9 15349934 [A/G] rs7870630 9 15350556 [T/C] rs680686 9 15351450 [A/G] rs681093 9 15351505 [T/C] rs632317 9 15355480 [T/G] rs519761 9 15357041 [T/C] rs641274 9 15357727 [A/C] rs10961982 9 15359217 [T/C] rs10810383 9 15367759 [T/C] rs1105191 9 15370575 [A/G] rs10961996 9 15370832 [A/G] rs10961997 9 15371675 [A/C] rs2804982 9 15378449 [T/C] rs1891847 9 15380657 [A/G] rs2798750 9 15382572 [A/G] rs4741495 9 15384135 [T/C] rs12339025 9 15385568 [A/G] rs12375629 9 15386433 [T/C] rs10962014 9 15386490 [A/G] rs10962015 9 15387949 [A/G] rs2490855 9 15389610 [T/G] rs2040071 9 15393381 [A/G] rs2798716 9 15397969 [A/C] rs6474915 9 15415461 [A/G] rs10117968 9 15420805 [T/G] rs2175259 9 15421423 [T/C] rs10738395 9 15429539 [A/G] NM_001039697 SNAPC3 Silent rs1123038 9 15431326 [T/C] NM_001039697 SNAPC3 Silent rs907076 9 15443430 [T/C] NM_001039697 SNAPC3 Silent rs3087653 9 15459821 [A/C] NM_001039697 SNAPC3 EXON Missense_E398A rs12093 9 15461506 [T/C] NM_001039697 SNAPC3 EXON Silent rs16933270 9 15466905 [A/G] NM_033222,NM_001128217 PSIP1,PSIP1 Silent,Silent rs909323 9 15467175 [T/G] NM_033222,NM_001128217 PSIP1,PSIP1 Silent,Silent rs10810390 9 15471054 [A/G] NM_033222,NM_001128217,NM_001317900,NM_021144,NM_001317898 PSIP1,PSIP1,PSIP1,PSIP1,PSIP1 EXON Silent,Silent,Silent,Silent,Silent rs7862428 9 15482976 [T/C] NM_033222,NM_001128217,NM_001317900,NM_021144,NM_001317898 PSIP1,PSIP1,PSIP1,PSIP1,PSIP1 Silent,Silent,Silent,Silent,Silent rs1033056 9 15483211 [A/G] NM_033222,NM_001128217,NM_001317900,NM_021144,NM_001317898 PSIP1,PSIP1,PSIP1,PSIP1,PSIP1 Silent,Silent,Silent,Silent,Silent rs16933329 9 15496377 [A/G] NM_033222,NM_001128217,NM_001317900,NM_021144,NM_001317898 PSIP1,PSIP1,PSIP1,PSIP1,PSIP1 Silent,Silent,Silent,Silent,Silent rs12336509 9 15501753 [T/C] NM_033222,NM_001128217,NM_001317900,NM_021144,NM_001317898 PSIP1,PSIP1,PSIP1,PSIP1,PSIP1 Silent,Silent,Silent,Silent,Silent rs7857933 9 15516375 [A/G] rs12006227 9 15517096 [A/G] rs10125713 9 15517742 [A/G] rs7856710 9 15521362 [A/G] rs1397213 9 15524911 [T/C] rs7871956 9 15530283 [A/G] rs2457637 9 15533394 [T/C] rs6474929 9 15533415 [A/C] rs10962059 9 15536429 [A/G] rs10119257 9 15552399 [T/C] rs2821545 9 15564904 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs4740615 9 15574853 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs192466 9 15585395 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs4741510 9 15591372 [A/T] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 EXON Missense_S121T,Missense_S28T,Missense_S121T rs2055772 9 15602101 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs3129709 9 15609608 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs276438 9 15612830 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs276437 9 15614344 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs405352 9 15623462 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs4740619 9 15634326 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs12340969 9 15645713 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1553727 9 15656806 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs10756688 9 15660497 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs6474941 9 15661859 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1355171 9 15681694 [A/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs10733295 9 15681901 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs2175083 9 15696281 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1396707 9 15705395 [T/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs4741534 9 15715215 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs10962128 9 15726057 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs6474957 9 15735854 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs7467207 9 15746302 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs6474967 9 15760988 [T/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1592099 9 15765856 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1539171 9 15776138 [T/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1970498 9 15776290 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1539172 9 15784631 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 EXON Missense_K1069R,Missense_K984R,Missense_K1077R rs955193 9 15788170 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs7853304 9 15788187 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs2105317 9 15799343 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs12002511 9 15811988 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs9406537 9 15815246 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs7019205 9 15823667 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs4741545 9 15830506 [T/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs12000772 9 15845388 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs7852250 9 15849304 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1341740 9 15850604 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1578558 9 15855317 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs10810456 9 15869845 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs770204 9 15870465 [A/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs7867018 9 15872875 [T/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1169470 9 15876247 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs9406556 9 15889411 [T/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs770218 9 15891314 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1169478 9 15895539 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1773062 9 15896393 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1341729 9 15898228 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1891210 9 15900348 [T/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs7035363 9 15901751 [T/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs3008702 9 15909450 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs10810478 9 15921354 [A/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs1328285 9 15922137 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs3008683 9 15923770 [T/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs16933805 9 15925200 [T/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs7469281 9 15937691 [A/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs12684785 9 15942554 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs2987070 9 15942765 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs10756727 9 15958806 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs4741552 9 15959700 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs3008751 9 15967745 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs3008750 9 15967923 [T/C] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 Silent,Silent,Silent rs10756728 9 15973288 [A/G] NM_173550,NM_001348002,NM_001355547 CCDC171,CCDC171,CCDC171 EXON Silent,Silent,Silent rs10756730 9 15975069 [T/C] rs1927699 9 15986487 [A/G] rs3008731 9 16003441 [A/G] rs12003855 9 16004670 [A/G] rs3008725 9 16009322 [A/G] rs2987081 9 16012046 [T/C] rs10962251 9 16012225 [A/C] rs10810516 9 16020997 [T/C] rs16933967 9 16022910 [A/G] rs10756734 9 16026444 [T/C] rs10810517 9 16026664 [T/C] rs7848880 9 16028693 [A/G] rs1887667 9 16033109 [T/G] rs1410454 9 16042193 [A/C] rs1328297 9 16046371 [A/G] rs3008694 9 16046463 [A/G] rs10962263 9 16046983 [A/G] rs1328299 9 16047293 [T/G] rs10733307 9 16051490 [T/C] rs1556045 9 16053710 [A/G] rs1014308 9 16053792 [A/G] rs10962266 9 16054048 [T/C] rs2987089 9 16056836 [A/G] rs3008709 9 16057378 [A/C] rs2987093 9 16060417 [T/C] rs2026662 9 16060746 [A/G] rs10114770 9 16061329 [T/C] rs9886829 9 16061960 [A/G] rs9298745 9 16063191 [A/C] rs17784100 9 16064646 [A/G] rs10511612 9 16066169 [T/C] rs6475004 9 16069629 [T/G] rs4961643 9 16070094 [A/G] rs11999147 9 16073639 [A/G] rs10962269 9 16074726 [A/G] rs1887677 9 16079296 [A/G] rs11789353 9 16081108 [A/G] rs11789951 9 16082467 [A/G] rs10511613 9 16083133 [A/G] rs10962272 9 16084769 [T/C] rs7023221 9 16085262 [T/C] rs4532696 9 16087903 [A/G] rs28454876 9 16091590 [T/C] rs2891006 9 16092087 [T/C] rs9695323 9 16092485 [T/C] rs943784 9 16096547 [T/C] rs12005226 9 16098105 [T/C] rs867780 9 16103333 [T/C] rs765509 9 16106801 [T/G] rs10962284 9 16108051 [A/G] rs4961466 9 16110293 [T/G] rs16934049 9 16110623 [T/G] rs7873155 9 16118758 [T/G] rs7028308 9 16123596 [T/C] rs7036825 9 16125443 [A/C] rs7863615 9 16130937 [T/C] rs12553725 9 16131805 [A/G] rs10962290 9 16133853 [A/C] rs12341724 9 16135924 [A/C] rs10738431 9 16136054 [T/C] rs10810530 9 16145299 [T/C] rs1410448 9 16147687 [T/C] rs7872685 9 16150498 [A/G] rs2067789 9 16151623 [T/C] rs2067790 9 16151659 [T/C] rs7023487 9 16152308 [A/C] rs7851897 9 16152635 [T/C] rs7022227 9 16155473 [T/C] rs729119 9 16155596 [A/C] rs10962302 9 16160638 [A/G] rs11999148 9 16161217 [T/G] rs4961664 9 16161233 [T/C] rs10962304 9 16162546 [A/G] rs10962305 9 16163344 [A/G] rs9298746 9 16168116 [A/G] rs1328293 9 16172580 [T/G] rs12238080 9 16177206 [T/C] rs7029038 9 16178112 [T/G] rs16934192 9 16185090 [T/G] rs10113994 9 16185621 [A/G] rs16934196 9 16186417 [A/G] rs1999472 9 16186705 [A/G] rs7852086 9 16189987 [T/G] rs10962321 9 16190403 [A/G] rs4961665 9 16191258 [T/G] rs16934202 9 16191512 [A/G] rs16934205 9 16195381 [T/C] rs12002003 9 16196717 [A/G] rs7871208 9 16199819 [T/C] rs7856829 9 16201094 [A/G] rs16934226 9 16201347 [A/G] rs7872577 9 16201392 [T/G] rs16934229 9 16201612 [A/G] rs7034501 9 16202988 [T/C] rs885290 9 16203309 [A/G] rs2151061 9 16205165 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs10122810 9 16206138 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs16934247 9 16206430 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs4961669 9 16206695 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs1332488 9 16207279 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs12350437 9 16207913 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs1115245 9 16209181 [A/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs1412539 9 16210163 [T/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs1412538 9 16210295 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs1412537 9 16210330 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs10962333 9 16210610 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs7044238 9 16211137 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs12554091 9 16211712 [T/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs10511616 9 16212766 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs10125444 9 16212992 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs16934264 9 16215744 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs17725257 9 16216102 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs1412536 9 16216437 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs7040148 9 16217587 [T/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs7023845 9 16217690 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs16934273 9 16218382 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs12004126 9 16221343 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs12004220 9 16221771 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs11793155 9 16221932 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs7038757 9 16222474 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs16934286 9 16230184 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs7861430 9 16230349 [A/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs9407727 9 16231174 [T/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs9407728 9 16231861 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs10810534 9 16233085 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs1576840 9 16234356 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs4961681 9 16236676 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs10810537 9 16237614 [A/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs16934302 9 16241198 [T/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs7875247 9 16242088 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs7864095 9 16243361 [A/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs7850689 9 16243514 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs1412535 9 16244120 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs2021322 9 16244199 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs10738433 9 16245170 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs2151065 9 16245716 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs7863065 9 16246539 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs1571907 9 16247466 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs6415726 9 16247629 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs4961685 9 16249141 [A/G] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs2151064 9 16249878 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs2095074 9 16251695 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs885386 9 16252410 [T/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs12683780 9 16252807 [A/C] NM_001271829,NR_073471,NM_001364979 C9orf92,C9orf92,C9orf92 Silent,Silent,Silent rs7027156 9 16253904 [A/G] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs3898525 9 16255704 [A/G] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs10810541 9 16256275 [A/G] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs7040587 9 16256964 [A/G] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs1888952 9 16258118 [A/G] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs1888951 9 16260837 [T/G] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs7034609 9 16260884 [A/G] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs9406600 9 16261940 [T/C] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs9298751 9 16263887 [T/C] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs1571906 9 16264733 [T/G] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs12005048 9 16265063 [A/G] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs7857514 9 16266732 [T/C] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs7033852 9 16267557 [A/G] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs7856337 9 16271779 [T/C] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs4335227 9 16273781 [T/C] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs6475020 9 16275107 [A/G] NR_073471,NM_001364979 C9orf92,C9orf92 Silent,Silent rs9406606 9 16277713 [T/C] rs1332478 9 16278130 [A/C] rs1105177 9 16280194 [T/C] rs7026127 9 16283279 [A/C] rs7858291 9 16284231 [T/C] rs10962366 9 16286587 [T/C] rs9406607 9 16287839 [T/C] rs9407735 9 16287981 [T/C] rs6475025 9 16289428 [T/C] rs7850784 9 16289910 [A/G] rs9407736 9 16291556 [A/G] rs1360549 9 16292669 [A/C] rs9406613 9 16296851 [A/G] rs7036684 9 16303495 [A/C] rs10962371 9 16305615 [A/G] rs7018975 9 16306523 [A/C] rs6475034 9 16306543 [T/C] rs7043435 9 16308000 [T/C] rs12376143 9 16308805 [T/C] rs9406618 9 16309527 [T/C] rs9407751 9 16310723 [T/G] rs6475036 9 16313409 [T/C] rs7867771 9 16314909 [T/C] rs16934430 9 16315833 [T/G] rs7034935 9 16316899 [T/C] rs7853960 9 16318055 [A/G] rs7026479 9 16318314 [T/C] rs12552591 9 16318869 [A/G] rs914656 9 16321008 [A/G] rs16934439 9 16321578 [T/G] rs12686344 9 16324236 [A/G] rs7857417 9 16324261 [A/G] rs7872913 9 16324374 [T/C] rs12002852 9 16326380 [A/G] rs11788833 9 16328103 [T/C] rs4961697 9 16328605 [A/G] rs12347671 9 16328688 [A/G] rs1888955 9 16329537 [T/C] rs9407756 9 16331304 [T/G] rs7019421 9 16334412 [T/C] rs12683609 9 16334761 [A/C] rs10810557 9 16336250 [T/C] rs7033184 9 16337744 [A/G] rs4961699 9 16339369 [A/G] rs4961701 9 16339512 [A/G] rs4961702 9 16340357 [A/G] rs11794667 9 16342065 [A/G] rs13298313 9 16342994 [T/C] rs7035494 9 16343135 [A/G] rs10962386 9 16345371 [A/G] rs12338843 9 16346254 [A/G] rs12380074 9 16348639 [A/G] rs7030722 9 16349135 [A/G] rs4961706 9 16349953 [T/G] rs4961707 9 16350160 [T/G] rs4961708 9 16350474 [A/G] rs4526456 9 16353534 [A/G] rs4961479 9 16354862 [A/G] rs4961480 9 16354904 [T/C] rs7861586 9 16355626 [A/G] rs6475044 9 16355870 [T/C] rs16934512 9 16358278 [A/C] rs4961485 9 16360889 [T/C] rs4961712 9 16360934 [T/C] rs9407760 9 16363460 [T/C] rs7019169 9 16364351 [A/C] rs9407761 9 16364612 [T/C] rs12000507 9 16364727 [T/C] rs10962397 9 16364925 [T/C] rs10511618 9 16366266 [T/C] rs10962398 9 16366496 [A/G] rs7864648 9 16368732 [T/G] rs10123982 9 16369067 [T/C] rs10962402 9 16372094 [A/G] rs10123044 9 16373545 [T/C] rs9298759 9 16375403 [A/G] rs9298760 9 16376437 [T/C] rs9407764 9 16377360 [T/C] rs4620378 9 16384212 [T/C] rs4612476 9 16388447 [A/C] rs4495533 9 16388491 [A/G] rs7033140 9 16390697 [A/G] rs4442246 9 16391294 [A/G] rs7041706 9 16392810 [A/G] rs7023798 9 16395766 [A/C] rs10962417 9 16397614 [A/G] rs4287030 9 16398267 [A/G] rs7036631 9 16398279 [A/G] rs17797890 9 16399927 [T/C] rs2209867 9 16402878 [A/G] rs9407773 9 16404794 [A/C] rs9406646 9 16405573 [T/C] rs2182901 9 16406897 [A/G] rs9406647 9 16407821 [A/C] rs7025750 9 16408042 [T/C] rs717267 9 16408826 [A/G] rs7853747 9 16411463 [T/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 EXON Silent,Silent,Silent rs16934619 9 16412868 [T/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 EXON Silent,Silent,Silent rs7035049 9 16413779 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 EXON Silent,Silent,Silent rs16934621 9 16414756 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 EXON Silent,Silent,Silent rs2296864 9 16415459 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 EXON Silent,Silent,Silent rs10511621 9 16423164 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10511619 9 16424985 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs16934644 9 16426951 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7859226 9 16430599 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs6475053 9 16432118 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7867445 9 16432426 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs3739715 9 16435714 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 EXON Synonymous_L826L,Synonymous_L784L,Synonymous_L731L rs3739714 9 16435848 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 EXON Missense_T782A,Missense_T740A,Missense_T687A rs4961490 9 16436544 [A/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 EXON Missense_L550V,Missense_L508V,Missense_L455V rs4545191 9 16446091 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7046026 9 16449673 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs12338207 9 16449788 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810564 9 16450274 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1927621 9 16453551 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7864652 9 16456759 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1927640 9 16456965 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10115759 9 16458889 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1887620 9 16459175 [T/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10733310 9 16464980 [T/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs2274557 9 16473118 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7046884 9 16476144 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7868285 9 16480296 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs4961719 9 16482083 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs997693 9 16484731 [T/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs997694 9 16484870 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs943750 9 16486142 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7872124 9 16488167 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1927633 9 16489981 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs12056994 9 16492516 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1927631 9 16500789 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7043485 9 16505902 [T/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7849139 9 16507737 [A/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10962471 9 16518030 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7044658 9 16519571 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs12345513 9 16520103 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10962472 9 16520681 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs4961492 9 16520958 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7031782 9 16525841 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs17811225 9 16526653 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs16934786 9 16526910 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs16934787 9 16527027 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs3814111 9 16527354 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7867633 9 16527829 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs4961722 9 16529174 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10962474 9 16529554 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7866317 9 16532764 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10962477 9 16538942 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs2891071 9 16540987 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs2149157 9 16547743 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs2149158 9 16547755 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs6475059 9 16554405 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7862158 9 16561617 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10962493 9 16572137 [A/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1927618 9 16572826 [A/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs12352543 9 16573685 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs12003277 9 16575774 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10123558 9 16578434 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1415476 9 16587648 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10511622 9 16596071 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs12004893 9 16601082 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs16934855 9 16609109 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1337391 9 16611692 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs13290470 9 16619529 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1337387 9 16628401 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs17739929 9 16628828 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs950359 9 16629024 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810580 9 16629923 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7039706 9 16645242 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10962519 9 16656587 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1415471 9 16656653 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10756776 9 16658392 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810584 9 16658915 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10115913 9 16659259 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7860104 9 16661210 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7046154 9 16664759 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs12344619 9 16669114 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1337395 9 16669912 [A/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810585 9 16671045 [T/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs13285378 9 16671729 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810586 9 16673676 [A/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7871223 9 16676486 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs4961729 9 16676601 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7875154 9 16677221 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10738445 9 16680138 [A/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10962540 9 16682689 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs4961731 9 16683543 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10511624 9 16695690 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs12375507 9 16699832 [A/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs16934920 9 16702394 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7038172 9 16708269 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10738451 9 16713666 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1330303 9 16715826 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10962549 9 16719445 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7869097 9 16719631 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs4961737 9 16721067 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810597 9 16722304 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs2282071 9 16727619 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1856132 9 16730653 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1330302 9 16730753 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1970285 9 16738889 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7034961 9 16744613 [T/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1330298 9 16755121 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810618 9 16761648 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1330300 9 16762537 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810619 9 16763140 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7850168 9 16766118 [A/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7859111 9 16768707 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10962579 9 16772380 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810621 9 16776500 [A/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10123118 9 16778780 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10962589 9 16783380 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10122736 9 16783482 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810627 9 16786071 [A/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7860932 9 16786898 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810628 9 16787406 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs3927536 9 16787670 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810632 9 16789024 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10756815 9 16789081 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs4961496 9 16789652 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs4961760 9 16789878 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10962594 9 16791743 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10120562 9 16793104 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7858031 9 16794734 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs11999769 9 16794763 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810635 9 16795241 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10962599 9 16795286 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs16935073 9 16795790 [A/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs4961497 9 16797461 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10962604 9 16799569 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs12236540 9 16803158 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7861591 9 16804447 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs12351269 9 16806521 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs2243699 9 16806790 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs11788776 9 16810347 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7852779 9 16812767 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10962619 9 16815861 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs3936215 9 16816755 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810639 9 16824430 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7043062 9 16825110 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7046369 9 16831375 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7030528 9 16831748 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs4995398 9 16838211 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810642 9 16841515 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810643 9 16841628 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs4961499 9 16844949 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1339548 9 16846323 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs1339550 9 16854839 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10756819 9 16858084 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7861573 9 16862280 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs12683636 9 16862691 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs2153271 9 16864521 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs7019402 9 16869240 [T/C] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810649 9 16870421 [A/G] NM_017637,NM_001317939,NM_001317940 BNC2,BNC2,BNC2 Silent,Silent,Silent rs10810656 9 16877758 [T/C] rs7868212 9 16881914 [A/G] rs1890640 9 16882186 [T/C] rs12006360 9 16887073 [T/C] rs4436220 9 16894953 [T/C] rs10733325 9 16895610 [T/C] rs10962673 9 16898229 [A/G] rs10733333 9 16903446 [A/G] rs7033354 9 16904846 [T/C] rs10810666 9 16911666 [T/C] rs3814112 9 16914967 [T/C] rs3814113 9 16915021 [T/C] rs10810681 9 16929803 [A/G] rs10962718 9 16931342 [T/C] rs10962719 9 16931410 [T/C] rs10962725 9 16933037 [A/G] rs7019530 9 16936082 [A/G] rs7035981 9 16936283 [T/C] rs10810685 9 16937341 [A/G] rs4551457 9 16937515 [A/G] rs7875833 9 16941006 [T/G] rs1538589 9 16942901 [T/C] rs1538590 9 16943046 [T/C] rs6475098 9 16948004 [T/G] rs10756848 9 16948706 [T/C] rs10962763 9 16950860 [A/C] rs4961428 9 16951644 [A/G] rs10962765 9 16955672 [T/C] rs16935175 9 16955901 [T/C] rs11999020 9 16958312 [A/G] rs7042688 9 16959184 [A/C] rs16935195 9 16961911 [A/G] rs11791614 9 16963863 [A/G] rs10511629 9 16969197 [A/G] rs10511628 9 16969505 [A/G] rs4961513 9 16971165 [A/G] rs953586 9 16974716 [T/G] rs3933182 9 16979089 [A/G] rs1032217 9 16982584 [A/G] rs10810702 9 16983321 [A/G] rs10962794 9 16984995 [T/C] rs1487511 9 16986264 [A/G] rs1487509 9 16986415 [T/C] rs10962795 9 16987379 [A/C] rs406268 9 16997535 [T/C] rs374785 9 16998247 [T/C] rs448034 9 16998460 [A/G] rs1487504 9 17000855 [A/G] rs10962808 9 17002275 [A/G] rs10810705 9 17004418 [T/C] rs263628 9 17008137 [A/G] rs7850290 9 17009347 [T/C] rs263655 9 17009481 [A/G] rs10962814 9 17010201 [T/C] rs7469906 9 17010426 [A/G] rs1386570 9 17011346 [A/C] rs1487500 9 17012877 [A/G] rs263650 9 17012980 [T/G] rs1487499 9 17014026 [A/G] rs13299954 9 17015692 [T/G] rs263648 9 17015867 [A/C] rs381306 9 17017284 [A/C] rs263640 9 17019121 [A/G] rs263636 9 17022423 [A/G] rs263635 9 17022777 [A/C] rs450114 9 17024496 [T/C] rs263569 9 17030146 [A/G] rs263576 9 17034019 [T/G] rs263585 9 17041557 [A/G] rs366216 9 17053484 [A/C] rs2492870 9 17058576 [T/C] rs2129626 9 17071162 [A/C] rs263561 9 17078922 [A/C] rs10962860 9 17082040 [T/C] rs10962862 9 17088668 [A/G] rs2200599 9 17105586 [A/G] rs2029247 9 17117875 [T/C] rs16935340 9 17118007 [T/C] rs972464 9 17120621 [T/C] rs411167 9 17130360 [T/C] rs398527 9 17133559 [A/G] rs4493995 9 17134245 [A/G] rs16935364 9 17143709 [T/C] NM_001286984,NM_017738,NM_001286985,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN,CNTLN,CNTLN Silent,Silent,Silent,Silent,Silent rs2779771 9 17147361 [A/G] NM_001286984,NM_017738,NM_001286985,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN,CNTLN,CNTLN Silent,Silent,Silent,Silent,Silent rs2815179 9 17147702 [A/C] NM_001286984,NM_017738,NM_001286985,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN,CNTLN,CNTLN Silent,Silent,Silent,Silent,Silent rs9407787 9 17158245 [T/C] NM_001286984,NM_017738,NM_001286985,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN,CNTLN,CNTLN Silent,Silent,Silent,Silent,Silent rs10511633 9 17161527 [T/G] NM_001286984,NM_017738,NM_001286985,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN,CNTLN,CNTLN Silent,Silent,Silent,Silent,Silent rs6475111 9 17162413 [T/C] NM_001286984,NM_017738,NM_001286985,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN,CNTLN,CNTLN Silent,Silent,Silent,Silent,Silent rs2815175 9 17165698 [A/G] NM_001286984,NM_017738,NM_001286985,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN,CNTLN,CNTLN Silent,Silent,Silent,Silent,Silent rs7037191 9 17167963 [T/C] NM_001286984,NM_017738,NM_001286985,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN,CNTLN,CNTLN EXON Silent,Silent,Silent,Silent,Silent rs2815173 9 17181174 [T/G] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs2779761 9 17181689 [A/G] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs10962896 9 17190094 [T/C] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs4961534 9 17208589 [A/G] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs10962912 9 17219242 [T/C] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs16935412 9 17229028 [A/G] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs4961535 9 17230848 [A/G] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs4458955 9 17233530 [T/C] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs1582029 9 17243746 [T/C] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs6475125 9 17250170 [A/G] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs1591138 9 17261209 [A/G] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs10962988 9 17269437 [T/G] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs654521 9 17271858 [A/G] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs3808795 9 17273731 [A/G] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN EXON Missense_T284A,Missense_T284A,Missense_T284A rs2027014 9 17276104 [T/C] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs2779773 9 17278584 [A/G] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs13292550 9 17278726 [A/G] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs870270 9 17280616 [A/G] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs601960 9 17296630 [A/G] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN Silent,Silent,Silent rs646025 9 17300938 [A/C] NM_017738,NM_001114395,NM_001365029 CNTLN,CNTLN,CNTLN EXON Silent,Silent,Silent rs12004593 9 17303013 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs2780204 9 17305351 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs1759458 9 17307204 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs6475128 9 17309813 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs4621917 9 17318681 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs10963033 9 17322582 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs10963040 9 17334075 [T/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs3824393 9 17339585 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs3808782 9 17340864 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN EXON Missense_R562C,Missense_R562C rs10963050 9 17345018 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs2044119 9 17349864 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs10963072 9 17378776 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs10121841 9 17384923 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs1442522 9 17391531 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs7035276 9 17394536 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN EXON Missense_T695I,Missense_T695I rs3739489 9 17394996 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN EXON Synonymous_H848H,Synonymous_H848H rs4961557 9 17398404 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs4961559 9 17400701 [T/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs10963084 9 17404464 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs2593396 9 17417026 [T/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs1442514 9 17419319 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs1372698 9 17429714 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs1953105 9 17430610 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs10120156 9 17431760 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs1967357 9 17436662 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs11792612 9 17442000 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs1160340 9 17444294 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs4961441 9 17444478 [T/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs4961563 9 17444567 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs2593397 9 17451550 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs2004280 9 17451970 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs2593382 9 17454799 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs2197152 9 17457854 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs10756881 9 17463615 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs1837944 9 17466468 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs16935681 9 17470126 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs2441997 9 17474085 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs10756885 9 17480669 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs2383022 9 17485598 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs3780256 9 17486802 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs2383024 9 17487945 [T/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs2243877 9 17488111 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs10738478 9 17493937 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs4466495 9 17496114 [A/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs16935729 9 17500284 [T/C] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs16935740 9 17502006 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs2248136 9 17502205 [T/G] NM_017738,NM_001365029 CNTLN,CNTLN Silent,Silent rs3808777 9 17503073 [T/G] NM_017738,NM_001365029 CNTLN,CNTLN EXON Silent,Silent rs2593352 9 17503407 [A/G] NM_017738,NM_001365029 CNTLN,CNTLN EXON Silent,Silent rs12377369 9 17505228 [A/G] rs10963119 9 17507277 [A/G] rs12337784 9 17509083 [T/G] rs2593362 9 17511064 [A/G] rs7350278 9 17524038 [T/G] rs2593371 9 17531968 [T/C] rs11790958 9 17534540 [T/C] rs7866802 9 17539320 [T/C] rs1885170 9 17564267 [T/C] rs2754341 9 17572069 [T/C] rs7029216 9 17581039 [A/G] NM_003026 SH3GL2 Silent rs7047611 9 17585896 [A/G] NM_003026 SH3GL2 Silent rs10810812 9 17586101 [A/G] NM_003026 SH3GL2 Silent rs3780252 9 17589821 [T/G] NM_003026 SH3GL2 Silent rs4961575 9 17591830 [A/G] NM_003026 SH3GL2 Silent rs3808772 9 17598287 [T/C] NM_003026 SH3GL2 Silent rs2208485 9 17599212 [A/G] NM_003026 SH3GL2 Silent rs1010547 9 17599511 [A/G] NM_003026 SH3GL2 Silent rs3808769 9 17600659 [T/C] NM_003026 SH3GL2 Silent rs1535346 9 17602001 [T/G] NM_003026 SH3GL2 Silent rs1543479 9 17604934 [T/C] NM_003026 SH3GL2 Silent rs10115064 9 17605449 [T/C] NM_003026 SH3GL2 Silent rs3808762 9 17609045 [A/G] NM_003026 SH3GL2 Silent rs2145659 9 17609302 [A/G] NM_003026 SH3GL2 Silent rs1885166 9 17610211 [T/C] NM_003026 SH3GL2 Silent rs3808756 9 17613834 [A/G] NM_003026 SH3GL2 Silent rs3808755 9 17616193 [T/C] NM_003026 SH3GL2 Silent rs3824389 9 17616494 [A/G] NM_003026 SH3GL2 Silent rs3780247 9 17618048 [T/G] NM_003026 SH3GL2 Silent rs3808752 9 17621918 [T/C] NM_003026 SH3GL2 Silent rs1555422 9 17621965 [A/C] NM_003026 SH3GL2 Silent rs3808750 9 17622213 [A/G] NM_003026 SH3GL2 Silent rs9407817 9 17622897 [A/G] NM_003026 SH3GL2 Silent rs3824388 9 17624902 [A/G] NM_003026 SH3GL2 Silent rs2208494 9 17625002 [A/G] NM_003026 SH3GL2 Silent rs3808747 9 17626616 [T/C] NM_003026 SH3GL2 Silent rs3808745 9 17627988 [A/G] NM_003026 SH3GL2 Silent rs4504735 9 17630500 [T/C] NM_003026 SH3GL2 Silent rs3808742 9 17630591 [A/G] NM_003026 SH3GL2 Silent rs975697 9 17631186 [A/G] NM_003026 SH3GL2 Silent rs1998247 9 17631552 [A/C] NM_003026 SH3GL2 Silent rs2224448 9 17633023 [A/G] NM_003026 SH3GL2 Silent rs3808734 9 17633059 [A/G] NM_003026 SH3GL2 Silent rs2208496 9 17633232 [T/C] NM_003026 SH3GL2 Silent rs4961580 9 17634332 [A/G] NM_003026 SH3GL2 Silent rs6475158 9 17635712 [A/G] NM_003026 SH3GL2 Silent rs3808731 9 17637196 [A/G] NM_003026 SH3GL2 Silent rs2038521 9 17640022 [T/C] NM_003026 SH3GL2 Silent rs10963179 9 17640642 [T/C] NM_003026 SH3GL2 Silent rs3808727 9 17649842 [A/C] NM_003026 SH3GL2 Silent rs7039627 9 17650027 [T/C] NM_003026 SH3GL2 Silent rs7350202 9 17651870 [A/G] NM_003026 SH3GL2 Silent rs1536065 9 17655744 [A/G] NM_003026 SH3GL2 Silent rs10810817 9 17657019 [T/C] NM_003026 SH3GL2 Silent rs7866898 9 17657363 [T/G] NM_003026 SH3GL2 Silent rs7875763 9 17661406 [A/G] NM_003026 SH3GL2 Silent rs10963190 9 17662411 [A/G] NM_003026 SH3GL2 Silent rs3808720 9 17664191 [T/C] NM_003026 SH3GL2 Silent rs7047514 9 17673601 [A/G] NM_003026 SH3GL2 Silent rs16935873 9 17673923 [A/G] NM_003026 SH3GL2 Silent rs1570782 9 17684818 [A/C] NM_003026 SH3GL2 Silent rs10117362 9 17687412 [A/G] NM_003026 SH3GL2 Silent rs10118522 9 17690052 [T/G] NM_003026 SH3GL2 Silent rs3808713 9 17690836 [A/G] NM_003026 SH3GL2 Silent rs3808707 9 17694913 [A/G] NM_003026 SH3GL2 Silent rs3808703 9 17697735 [A/G] NM_003026 SH3GL2 Silent rs717373 9 17699909 [T/C] NM_003026 SH3GL2 Silent rs717372 9 17699981 [T/C] NM_003026 SH3GL2 Silent rs11791082 9 17700029 [A/G] NM_003026 SH3GL2 Silent rs998599 9 17700366 [A/G] NM_003026 SH3GL2 Silent rs16935912 9 17703386 [A/G] NM_003026 SH3GL2 Silent rs10491539 9 17708814 [T/G] NM_003026 SH3GL2 Silent rs2209437 9 17710407 [T/C] NM_003026 SH3GL2 Silent rs10756902 9 17710876 [A/G] NM_003026 SH3GL2 Silent rs3824379 9 17717228 [A/G] NM_003026 SH3GL2 Silent rs6475168 9 17717690 [T/C] NM_003026 SH3GL2 Silent rs7865066 9 17718918 [A/G] NM_003026 SH3GL2 Silent rs7850335 9 17720175 [T/C] NM_003026 SH3GL2 Silent rs10114474 9 17720884 [T/G] NM_003026 SH3GL2 Silent rs10756904 9 17726844 [T/G] NM_003026 SH3GL2 Silent rs1536078 9 17732138 [T/C] NM_003026 SH3GL2 Silent rs2383044 9 17735707 [A/G] NM_003026 SH3GL2 Silent rs2209440 9 17736342 [T/G] NM_003026 SH3GL2 Silent rs720268 9 17738857 [T/C] NM_003026 SH3GL2 Silent rs2383045 9 17739006 [T/C] NM_003026 SH3GL2 Silent rs4324999 9 17745053 [A/C] NM_003026 SH3GL2 Silent rs4338205 9 17746447 [A/G] NM_003026 SH3GL2 Silent rs3780226 9 17747173 [A/C] NM_003026 SH3GL2 Silent rs3808681 9 17750886 [T/C] NM_003026 SH3GL2 Silent rs2383047 9 17751559 [T/C] NM_003026 SH3GL2 Silent rs12376522 9 17756105 [T/C] NM_003026 SH3GL2 Silent rs3824371 9 17757573 [T/C] NM_003026 SH3GL2 Silent rs3824370 9 17758945 [A/C] NM_003026 SH3GL2 Silent rs10810848 9 17759497 [T/C] NM_003026 SH3GL2 Silent rs9407838 9 17760260 [T/C] NM_003026 SH3GL2 Silent rs1886589 9 17761379 [T/C] NM_003026 SH3GL2 Silent rs7020594 9 17762204 [T/C] NM_003026 SH3GL2 Silent rs7036989 9 17762217 [T/C] NM_003026 SH3GL2 Silent rs9406699 9 17765633 [T/C] NM_003026 SH3GL2 Silent rs4961593 9 17770090 [T/C] NM_003026 SH3GL2 Silent rs2224954 9 17771828 [A/C] NM_003026 SH3GL2 Silent rs9407852 9 17772029 [A/G] NM_003026 SH3GL2 Silent rs4302941 9 17772909 [A/G] NM_003026 SH3GL2 Silent rs10738489 9 17774662 [T/C] NM_003026 SH3GL2 Silent rs2209429 9 17775367 [T/C] NM_003026 SH3GL2 Silent rs9407863 9 17777485 [A/G] NM_003026 SH3GL2 Silent rs9407874 9 17788028 [T/C] NM_003026 SH3GL2 Silent rs9407881 9 17792845 [A/G] NM_003026 SH3GL2 Silent rs10963272 9 17793818 [A/G] NM_003026 SH3GL2 Silent rs9406736 9 17793903 [T/C] NM_003026 SH3GL2 Silent rs12552857 9 17794877 [T/C] NM_003026 SH3GL2 Silent rs7860861 9 17795169 [A/G] NM_003026 SH3GL2 Silent rs1049430 9 17796668 [T/G] NM_003026 SH3GL2 EXON Silent rs11791520 9 17801555 [A/G] rs4961598 9 17810983 [A/C] rs10810853 9 17814272 [T/C] rs7847005 9 17814761 [A/G] rs4961449 9 17815641 [A/G] rs7863227 9 17818646 [T/C] rs10120630 9 17819429 [A/C] rs7849308 9 17820465 [A/G] rs7869721 9 17825216 [A/C] rs10756917 9 17829258 [A/C] rs7029727 9 17829334 [A/G] rs10963299 9 17833057 [T/C] rs12682702 9 17836749 [A/G] rs6475180 9 17842652 [A/G] rs7853030 9 17849283 [T/C] rs5022716 9 17849996 [T/C] rs10116691 9 17853786 [T/C] rs6475184 9 17857109 [A/G] rs10963309 9 17866989 [A/G] rs7035861 9 17869637 [T/G] rs4474113 9 17874093 [A/G] rs4335230 9 17878879 [T/C] rs10963315 9 17880109 [A/G] rs10963317 9 17880914 [A/G] rs4524895 9 17889538 [A/G] rs4961604 9 17892368 [T/C] rs10733342 9 17895450 [A/G] rs4961454 9 17897525 [A/C] rs4284125 9 17899606 [T/C] rs10810866 9 17902936 [T/C] rs16936077 9 17904496 [T/C] rs2383053 9 17916555 [T/G] rs2891114 9 17918806 [A/G] rs12551822 9 17923017 [T/C] rs4325000 9 17931364 [A/G] rs1755288 9 17936628 [T/C] rs12684916 9 17937036 [A/G] rs12684923 9 17937168 [A/G] rs13287394 9 17937391 [T/C] rs1755289 9 17938351 [T/C] rs1778168 9 17940353 [A/G] rs4517213 9 17943442 [A/G] rs884097 9 17948600 [T/G] rs7867106 9 17951118 [T/C] rs12552709 9 17952583 [A/G] rs1620986 9 17961642 [A/C] rs1778185 9 17961773 [T/C] rs1329917 9 17962477 [A/C] rs1618634 9 17962581 [T/G] rs2772686 9 17963004 [A/G] rs2811806 9 17964514 [T/C] rs1778170 9 17967886 [A/G] rs2248505 9 17972059 [T/C] rs2840787 9 17976625 [T/C] rs2772695 9 17985166 [A/G] rs1755294 9 17985909 [T/C] rs2891117 9 17987408 [T/C] rs2253259 9 17988492 [A/C] rs2026764 9 17990785 [T/C] rs11789653 9 17993589 [A/C] rs7850890 9 17993668 [T/G] rs10963386 9 17999021 [A/G] rs10963391 9 18002205 [T/C] rs12346508 9 18003633 [T/G] rs10810880 9 18005075 [A/G] rs10511650 9 18005255 [T/C] rs10810882 9 18009671 [T/G] rs953923 9 18010619 [A/G] rs16936214 9 18010779 [T/C] rs7041139 9 18013733 [T/C] rs1329931 9 18016234 [T/C] rs1411250 9 18017007 [T/C] rs7027669 9 18017562 [A/G] rs10810886 9 18018207 [A/G] rs11792843 9 18023764 [T/C] rs10810888 9 18023977 [A/G] rs11789500 9 18028358 [A/C] rs10963401 9 18032367 [T/C] rs10963402 9 18032732 [T/C] rs10756924 9 18034266 [T/C] rs7034015 9 18036892 [A/G] rs1360235 9 18038013 [A/G] rs10810892 9 18044104 [A/C] rs10810893 9 18044532 [T/C] rs10963408 9 18044802 [A/G] rs10963411 9 18046233 [T/C] rs10810894 9 18046709 [T/C] rs10511649 9 18051005 [A/G] rs12002358 9 18054030 [A/G] rs7866191 9 18055440 [T/C] rs16936281 9 18058912 [T/C] rs10963421 9 18059000 [T/G] rs6475196 9 18061140 [A/C] rs7860145 9 18066074 [T/C] rs768703 9 18070475 [A/C] rs7860016 9 18071787 [A/G] rs7041361 9 18073936 [A/G] rs10738497 9 18074369 [T/C] rs12000388 9 18075710 [T/C] rs12156463 9 18080592 [A/C] rs1329924 9 18082567 [T/C] rs1329923 9 18082704 [T/C] rs10756929 9 18083153 [T/C] rs10963442 9 18090973 [T/C] rs10963443 9 18091440 [T/G] rs12348651 9 18093377 [T/C] rs7031350 9 18101081 [A/G] rs16936307 9 18101779 [A/C] rs11999221 9 18103264 [A/G] rs1411799 9 18106940 [T/C] rs12238245 9 18107808 [A/C] rs473309 9 18109831 [A/G] rs549861 9 18110037 [T/C] rs569644 9 18111646 [A/C] rs492960 9 18112889 [A/G] rs1556352 9 18115934 [A/G] rs4618799 9 18119661 [A/G] rs565342 9 18121492 [A/G] rs7852679 9 18122560 [A/G] rs16935857 9 18123222 [A/G] rs7864916 9 18125480 [A/G] rs579392 9 18125966 [T/C] rs17775838 9 18126900 [T/C] rs10810904 9 18127068 [A/G] rs10963462 9 18130036 [T/G] rs10963464 9 18130563 [A/G] rs2156684 9 18130574 [A/G] rs1360413 9 18132972 [T/C] rs763976 9 18134914 [A/C] rs4961625 9 18138042 [A/G] rs1360412 9 18139364 [A/G] rs11788314 9 18140689 [T/C] rs983230 9 18140836 [T/G] rs7034973 9 18142416 [T/C] rs7849137 9 18142898 [T/G] rs1411792 9 18149174 [A/G] rs1537136 9 18151987 [A/G] rs1411790 9 18154099 [A/C] rs12378327 9 18155747 [A/G] rs10810913 9 18161098 [A/G] rs2183645 9 18163165 [T/C] rs10963480 9 18163621 [T/C] rs10810914 9 18164545 [A/G] rs960232 9 18166112 [T/C] rs12006002 9 18166899 [T/C] rs10963486 9 18166934 [T/C] rs10810918 9 18170133 [T/C] rs1411795 9 18174349 [T/C] rs7025808 9 18177395 [A/G] rs10756945 9 18177598 [T/C] rs11789984 9 18182792 [A/G] rs2026903 9 18184051 [T/G] rs10810920 9 18185683 [T/C] rs7031744 9 18187403 [T/C] rs7032289 9 18187805 [T/C] rs4961627 9 18190434 [T/C] rs2187455 9 18193796 [A/G] rs7027648 9 18195685 [A/G] rs12378891 9 18199327 [A/G] rs10963511 9 18205105 [T/C] rs10963518 9 18208852 [A/G] rs10963523 9 18212306 [T/C] rs4424360 9 18214878 [T/C] rs1944765 9 18216312 [A/G] rs1944764 9 18216477 [T/C] rs10963526 9 18221377 [T/C] rs10756949 9 18224660 [T/C] rs1944751 9 18224772 [A/G] rs1944752 9 18231265 [A/G] rs7048005 9 18233494 [A/G] rs7038985 9 18238314 [T/C] rs10963534 9 18243696 [A/C] rs1944745 9 18244652 [T/C] rs2891126 9 18246545 [T/C] rs11790387 9 18248172 [T/C] rs17199255 9 18250459 [A/G] rs10810935 9 18251855 [A/G] rs10511645 9 18256588 [A/G] rs7846812 9 18258312 [T/G] rs2244327 9 18259760 [A/G] rs2819204 9 18261124 [T/C] rs2809854 9 18261485 [A/G] rs10117703 9 18265138 [A/G] rs2585578 9 18267185 [T/C] rs13286417 9 18268581 [T/C] rs7852708 9 18270369 [A/G] rs7861151 9 18272700 [A/G] rs7024439 9 18277618 [A/G] rs10810942 9 18280143 [A/G] rs7862129 9 18290410 [A/G] rs10963559 9 18291313 [A/G] rs10511641 9 18292118 [A/G] rs7849559 9 18294234 [A/G] rs7865006 9 18294429 [T/C] rs2891122 9 18295768 [T/C] rs10124717 9 18296065 [A/C] rs7865911 9 18298313 [T/C] rs7865940 9 18298447 [A/G] rs10963560 9 18300778 [A/G] rs4610856 9 18301116 [A/G] rs10810948 9 18301195 [A/C] rs4546750 9 18301446 [A/G] rs10963564 9 18302439 [A/G] rs12002789 9 18303691 [A/C] rs7023546 9 18317731 [T/C] rs4436218 9 18323073 [A/G] rs10756956 9 18323742 [A/G] rs4129608 9 18327215 [A/G] rs10810957 9 18332000 [T/C] rs16936603 9 18333039 [A/G] rs7021177 9 18334961 [T/G] rs4961638 9 18343434 [A/G] rs10156465 9 18343563 [T/C] rs12115643 9 18346755 [A/C] rs13286935 9 18347557 [T/C] rs4007665 9 18349993 [A/C] rs7047314 9 18358128 [A/G] rs9407897 9 18359014 [A/C] rs10511652 9 18362865 [A/G] rs1411153 9 18363377 [A/C] rs7020284 9 18364503 [T/C] rs9406744 9 18365045 [T/C] rs13284884 9 18368546 [T/G] rs10810961 9 18371966 [A/G] rs2809862 9 18372052 [A/G] rs2791443 9 18374849 [T/C] rs12337847 9 18375279 [T/G] rs9298792 9 18380943 [T/C] rs9407902 9 18383380 [A/G] rs10120545 9 18386757 [T/C] rs1329719 9 18387361 [A/G] rs7390284 9 18389998 [T/G] rs7389852 9 18390077 [A/G] rs2791445 9 18390666 [A/G] rs2791446 9 18392900 [T/G] rs2809861 9 18393875 [T/G] rs4961644 9 18395376 [A/G] rs1329718 9 18401585 [A/G] rs2153417 9 18403928 [A/G] rs17203690 9 18405209 [A/G] rs11789720 9 18407439 [A/G] rs10810964 9 18407521 [T/C] rs4961646 9 18408771 [A/C] rs2809856 9 18408970 [A/G] rs1591928 9 18411779 [T/C] rs10810967 9 18420347 [T/C] rs12348931 9 18422610 [A/G] rs12554111 9 18424272 [T/G] rs10125605 9 18425935 [A/G] rs7037636 9 18426053 [A/G] rs7873681 9 18428324 [A/G] rs2066151 9 18430297 [T/C] rs1329725 9 18430609 [A/G] rs12353438 9 18438047 [T/G] rs11789537 9 18438196 [T/C] rs5026813 9 18442710 [T/G] rs6475216 9 18444138 [T/C] rs17205381 9 18446300 [A/G] rs1888065 9 18446682 [A/G] rs1340043 9 18458068 [T/C] rs4961649 9 18463476 [T/C] rs16936735 9 18465292 [T/C] rs10123481 9 18465657 [T/C] rs1888067 9 18470996 [T/C] rs10511638 9 18472546 [A/G] rs13286264 9 18474280 [G/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 EXON Missense_A17G,Missense_A17G rs4961652 9 18485434 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs17207339 9 18486761 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs4961653 9 18494532 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs12000949 9 18495515 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1538999 9 18498954 [T/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10511659 9 18506190 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10810974 9 18512570 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs12002347 9 18513871 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10963622 9 18516637 [T/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs13298611 9 18516996 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1341061 9 18519699 [T/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1928535 9 18527831 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1341059 9 18528775 [T/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10963625 9 18530339 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs16936827 9 18530890 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs7863071 9 18531748 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs16936832 9 18533257 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 EXON Synonymous_G68G,Synonymous_G68G rs10810981 9 18533731 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs13295269 9 18537444 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs6475227 9 18538877 [T/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs7388822 9 18540040 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1341065 9 18541136 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs6475228 9 18541710 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs12376289 9 18542869 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs7042159 9 18545209 [A/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs16936853 9 18568527 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs13294657 9 18572900 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10756976 9 18574806 [A/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10732338 9 18575898 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10119114 9 18576556 [T/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs6475232 9 18580905 [T/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs7875881 9 18582065 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs7040072 9 18583822 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1576897 9 18590952 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs776794 9 18592374 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs949682 9 18595548 [T/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs4433237 9 18598470 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10810992 9 18599029 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs13301913 9 18600470 [A/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10756981 9 18601460 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs2184002 9 18601564 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1539000 9 18602403 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1889007 9 18606825 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10963668 9 18613798 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs16936905 9 18614351 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10810995 9 18614724 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs7868185 9 18615434 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1889005 9 18617617 [T/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1889006 9 18617804 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10963675 9 18619044 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10963676 9 18622043 [T/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1582017 9 18628672 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10963680 9 18629283 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1576900 9 18629792 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10963684 9 18631044 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10481564 9 18632108 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1332712 9 18632128 [A/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10963688 9 18632537 [T/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs13287455 9 18636050 [T/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10963691 9 18636286 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs17229989 9 18636986 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs776757 9 18637552 [T/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10811002 9 18637737 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1412671 9 18638143 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs12352788 9 18638517 [A/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs776755 9 18639300 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 EXON Missense_S242N,Missense_S242N rs702207 9 18639484 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10963695 9 18640364 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs11795307 9 18640431 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs7863100 9 18640590 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs776754 9 18641667 [T/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs776785 9 18651444 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs702203 9 18653324 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs947144 9 18653380 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs776782 9 18653773 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs4977520 9 18655961 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs4977522 9 18656065 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs776778 9 18657019 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs16936951 9 18657061 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs776777 9 18657487 [A/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs776776 9 18657558 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs776773 9 18659794 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs776771 9 18662292 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs776770 9 18663543 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs12352272 9 18664041 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs702202 9 18664420 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1332708 9 18666780 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10811008 9 18671467 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1332706 9 18672095 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs1360567 9 18675325 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs16936958 9 18675469 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs2487477 9 18676496 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs7045779 9 18676945 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10963718 9 18679376 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs10963719 9 18680586 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs776761 9 18680771 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs2811802 9 18682318 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs6475237 9 18683172 [A/G] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs2482972 9 18683680 [T/C] NM_001040272,NM_052866 ADAMTSL1,ADAMTSL1 Silent,Silent rs944720 9 18689243 [A/G] NM_001040272 ADAMTSL1 Silent rs2570569 9 18700566 [A/G] NM_001040272 ADAMTSL1 Silent rs521911 9 18708175 [T/G] NM_001040272 ADAMTSL1 Silent rs547927 9 18708788 [T/C] NM_001040272 ADAMTSL1 Silent rs518607 9 18709694 [A/G] NM_001040272 ADAMTSL1 Silent rs517764 9 18709767 [T/C] NM_001040272 ADAMTSL1 Silent rs530120 9 18717903 [A/G] NM_001040272 ADAMTSL1 Silent rs4977338 9 18718086 [T/G] NM_001040272 ADAMTSL1 Silent rs4977340 9 18718280 [A/G] NM_001040272 ADAMTSL1 Silent rs482009 9 18720104 [A/C] NM_001040272 ADAMTSL1 Silent rs522039 9 18723628 [A/G] NM_001040272 ADAMTSL1 Silent rs578602 9 18723698 [T/G] NM_001040272 ADAMTSL1 Silent rs574090 9 18724225 [A/C] NM_001040272 ADAMTSL1 Silent rs944716 9 18727082 [A/G] NM_001040272 ADAMTSL1 Silent rs532543 9 18727548 [A/G] NM_001040272 ADAMTSL1 Silent rs563805 9 18728689 [A/C] NM_001040272 ADAMTSL1 Silent rs476104 9 18730826 [A/G] NM_001040272 ADAMTSL1 Silent rs748108 9 18731160 [T/G] NM_001040272 ADAMTSL1 Silent rs944717 9 18732114 [T/G] NM_001040272 ADAMTSL1 Silent rs576026 9 18733462 [A/G] NM_001040272 ADAMTSL1 Silent rs568116 9 18738576 [A/G] NM_001040272 ADAMTSL1 Silent rs2482970 9 18739843 [T/C] NM_001040272 ADAMTSL1 Silent rs564014 9 18742434 [T/C] NM_001040272 ADAMTSL1 Silent rs10963743 9 18742990 [T/C] NM_001040272 ADAMTSL1 Silent rs1332704 9 18744966 [T/C] NM_001040272 ADAMTSL1 Silent rs1549989 9 18746561 [A/C] NM_001040272 ADAMTSL1 Silent rs1433808 9 18751126 [A/G] NM_001040272 ADAMTSL1 Silent rs7043157 9 18751638 [A/G] NM_001040272 ADAMTSL1 Silent rs2507122 9 18752860 [T/C] NM_001040272 ADAMTSL1 Silent rs10733356 9 18754211 [T/C] NM_001040272 ADAMTSL1 Silent rs2164000 9 18758205 [T/C] NM_001040272 ADAMTSL1 Silent rs10429480 9 18759822 [A/C] NM_001040272 ADAMTSL1 Silent rs4246839 9 18760031 [T/G] NM_001040272 ADAMTSL1 Silent rs11794380 9 18760665 [A/G] NM_001040272 ADAMTSL1 Silent rs1978746 9 18761099 [A/C] NM_001040272 ADAMTSL1 Silent rs1433810 9 18767301 [A/G] NM_001040272 ADAMTSL1 Silent rs10118309 9 18767830 [A/G] NM_001040272 ADAMTSL1 Silent rs1991883 9 18768201 [T/C] NM_001040272 ADAMTSL1 Silent rs12353465 9 18769219 [A/C] NM_001040272 ADAMTSL1 Silent rs7869627 9 18772370 [T/C] NM_001040272 ADAMTSL1 Silent rs4295757 9 18776116 [A/C] NM_001040272 ADAMTSL1 Silent rs2289006 9 18778319 [A/C] NM_001040272 ADAMTSL1 Silent rs11789625 9 18778885 [T/C] NM_001040272 ADAMTSL1 Silent rs12377348 9 18779938 [A/G] NM_001040272 ADAMTSL1 Silent rs1549988 9 18781154 [T/G] NM_001040272 ADAMTSL1 Silent rs7047163 9 18782512 [A/G] NM_001040272 ADAMTSL1 Silent rs10811032 9 18782704 [T/C] NM_001040272 ADAMTSL1 Silent rs715212 9 18786181 [A/C] NM_001040272 ADAMTSL1 Silent rs12379407 9 18786812 [T/C] NM_001040272 ADAMTSL1 Silent rs2033543 9 18787381 [A/C] NM_001040272 ADAMTSL1 Silent rs10963760 9 18787794 [A/G] NM_001040272 ADAMTSL1 Silent rs4977432 9 18789128 [T/C] NM_001040272 ADAMTSL1 Silent rs2033541 9 18789352 [A/G] NM_001040272 ADAMTSL1 Silent rs10963764 9 18791355 [T/C] NM_001040272 ADAMTSL1 Silent rs12343403 9 18791888 [T/C] NM_001040272 ADAMTSL1 Silent rs10963766 9 18795058 [A/G] NM_001040272 ADAMTSL1 Silent rs2289005 9 18795304 [T/C] NM_001040272 ADAMTSL1 Silent rs7847591 9 18795679 [A/G] NM_001040272 ADAMTSL1 Silent rs1433825 9 18796886 [T/G] NM_001040272 ADAMTSL1 Silent rs2289003 9 18797256 [A/G] NM_001040272 ADAMTSL1 Silent rs10963767 9 18797920 [T/C] NM_001040272 ADAMTSL1 Silent rs1433819 9 18798603 [A/G] NM_001040272 ADAMTSL1 Silent rs10963769 9 18801305 [T/C] NM_001040272 ADAMTSL1 Silent rs4977444 9 18804418 [T/G] NM_001040272 ADAMTSL1 Silent rs10963773 9 18805813 [T/C] NM_001040272 ADAMTSL1 Silent rs7870115 9 18806093 [A/G] NM_001040272 ADAMTSL1 Silent rs4977446 9 18806927 [T/G] NM_001040272 ADAMTSL1 Silent rs4977447 9 18806999 [A/G] NM_001040272 ADAMTSL1 Silent rs4977448 9 18807071 [T/G] NM_001040272 ADAMTSL1 Silent rs7854121 9 18809482 [A/G] NM_001040272 ADAMTSL1 Silent rs2148847 9 18810029 [T/C] NM_001040272 ADAMTSL1 Silent rs10963779 9 18811047 [A/G] NM_001040272 ADAMTSL1 Silent rs1433809 9 18817246 [A/C] NM_001040272 ADAMTSL1 Silent rs7874108 9 18817594 [T/C] NM_001040272 ADAMTSL1 Silent rs10156461 9 18818890 [T/C] NM_001040272 ADAMTSL1 Silent rs7021465 9 18818973 [A/G] NM_001040272 ADAMTSL1 Silent rs1980867 9 18819568 [T/G] NM_001040272 ADAMTSL1 Silent rs7019448 9 18823505 [T/C] NM_001040272 ADAMTSL1 Silent rs934469 9 18826500 [T/C] NM_001040272 ADAMTSL1 Silent rs10963786 9 18826610 [A/G] NM_001040272 ADAMTSL1 Silent rs718452 9 18827034 [T/C] NM_001040272 ADAMTSL1 Silent rs16937127 9 18830444 [A/G] NM_001040272 ADAMTSL1 Silent rs7858256 9 18831022 [T/C] NM_001040272 ADAMTSL1 Silent rs7858859 9 18831340 [A/G] NM_001040272 ADAMTSL1 Silent rs7859001 9 18831444 [A/G] NM_001040272 ADAMTSL1 Silent rs10122919 9 18832027 [T/C] NM_001040272 ADAMTSL1 Silent rs10811043 9 18832659 [A/G] NM_001040272 ADAMTSL1 Silent rs7039188 9 18833014 [A/G] NM_001040272 ADAMTSL1 Silent rs10963788 9 18833547 [T/C] NM_001040272 ADAMTSL1 Silent rs1347265 9 18835308 [A/C] NM_001040272 ADAMTSL1 Silent rs7859917 9 18847325 [T/C] NM_001040272 ADAMTSL1 Silent rs1368771 9 18848066 [A/G] NM_001040272 ADAMTSL1 Silent rs1001379 9 18848686 [A/C] NM_001040272 ADAMTSL1 Silent rs12003140 9 18849098 [T/C] NM_001040272 ADAMTSL1 Silent rs1814370 9 18853257 [T/G] NM_001040272 ADAMTSL1 Silent rs11791292 9 18853327 [T/G] NM_001040272 ADAMTSL1 Silent rs10963805 9 18856967 [A/G] NM_001040272 ADAMTSL1 Silent rs10963806 9 18857005 [T/C] NM_001040272 ADAMTSL1 Silent rs10811051 9 18861021 [T/C] NM_001040272 ADAMTSL1 Silent rs12685549 9 18865803 [A/G] NM_001040272 ADAMTSL1 Silent rs1897725 9 18866563 [T/C] NM_001040272 ADAMTSL1 Silent rs10963814 9 18872273 [A/C] NM_001040272 ADAMTSL1 Silent rs7047294 9 18877987 [A/C] NM_001040272 ADAMTSL1 Silent rs2082580 9 18878842 [A/G] NM_001040272 ADAMTSL1 Silent rs7850792 9 18880709 [T/C] NM_001040272 ADAMTSL1 Silent rs1368772 9 18882562 [T/C] NM_001040272 ADAMTSL1 Silent rs2209778 9 18883301 [A/G] NM_001040272 ADAMTSL1 Silent rs2099392 9 18884432 [T/G] NM_001040272 ADAMTSL1 Silent rs4977265 9 18885598 [T/C] NM_001040272 ADAMTSL1 Silent rs2082581 9 18886370 [T/C] NM_001040272 ADAMTSL1 Silent rs7030565 9 18891040 [A/G] NM_001040272 ADAMTSL1 Silent rs934480 9 18891487 [A/C] NM_001040272 ADAMTSL1 Silent rs2164001 9 18891793 [A/G] NM_001040272 ADAMTSL1 Silent rs7031396 9 18891910 [A/G] NM_001040272 ADAMTSL1 Silent rs10811055 9 18894714 [T/C] NM_001040272 ADAMTSL1 Silent rs2082582 9 18896061 [A/G] NM_001040272 ADAMTSL1 Silent rs1327504 9 18903330 [T/C] NM_001040272 ADAMTSL1 Silent rs7467533 9 18903625 [A/C] NM_001040272 ADAMTSL1 Silent rs7864878 9 18905289 [A/G] NM_001040272 ADAMTSL1 Silent rs13285304 9 18905525 [T/G] NM_001040272 ADAMTSL1 Silent rs945440 9 18907551 [T/C] NM_001040272 ADAMTSL1 Silent rs945441 9 18907769 [A/G] NM_001040272 ADAMTSL1 Silent rs16937177 9 18909597 [A/G] NM_001040272 ADAMTSL1 EXON Silent rs10117672 9 18909703 [A/G] NM_001040272 ADAMTSL1 EXON Silent rs11794832 9 18910581 [T/C] NM_001040272 ADAMTSL1 EXON Silent rs16937178 9 18911029 [T/C] rs17808244 9 18913052 [T/C] rs10811060 9 18913080 [A/G] rs10811061 9 18914103 [A/G] rs7860467 9 18914729 [A/C] rs12345835 9 18916311 [A/C] rs1932458 9 18917251 [T/C] rs2182729 9 18917347 [T/C] rs2148850 9 18917483 [T/C] rs4540491 9 18918845 [T/C] rs10811063 9 18921386 [T/G] rs731529 9 18924136 [A/G] rs7022140 9 18924463 [A/G] rs4977266 9 18925343 [A/C] rs7031603 9 18926997 [A/G] rs4977467 9 18927177 [A/C] rs945442 9 18927768 [A/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 EXON Silent,Silent,Silent rs945443 9 18927818 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 EXON Silent,Silent,Silent rs1052448 9 18928039 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 EXON Silent,Silent,Silent rs7871217 9 18929692 [A/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs4977469 9 18930880 [T/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs1932456 9 18932805 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs4977474 9 18934303 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs10963844 9 18935680 [T/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs1977445 9 18937624 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs945445 9 18939948 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs10757004 9 18940950 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs7032675 9 18944389 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs7864679 9 18945868 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs7045203 9 18947253 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs4977476 9 18948086 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs7021572 9 18950895 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 EXON Missense_K27E,Silent,Missense_K27E rs12115446 9 18952553 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs4977477 9 18953625 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs2039010 9 18955861 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs1006120 9 18956317 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs6475276 9 18958107 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs10511666 9 18969422 [A/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs7024351 9 18972801 [T/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs7856285 9 18973653 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs6475294 9 18973918 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs6475295 9 18974072 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs6475298 9 18978625 [A/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs7037837 9 18984007 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs12552916 9 18986580 [A/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs10511667 9 18989696 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs4506313 9 18990027 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs7038838 9 18993933 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs10963898 9 18995323 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs7858618 9 19007561 [T/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs10811094 9 19009041 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs10811095 9 19010440 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs10811097 9 19010867 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs16937267 9 19011300 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs10811099 9 19017723 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs10963906 9 19017868 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs12349207 9 19019820 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs10511668 9 19022470 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs10963912 9 19022995 [A/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs7028384 9 19026350 [T/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs10757024 9 19030014 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs10963919 9 19031231 [A/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 Silent,Silent,Silent rs17810415 9 19032907 [A/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 EXON Silent,Silent,Silent rs10963921 9 19033006 [T/G] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 EXON Silent,Silent,Silent rs10963922 9 19033058 [A/C] NM_153707,NM_001287049,NM_001287050 SAXO1,SAXO1,SAXO1 EXON Silent,Silent,Silent rs10125646 9 19045502 [A/G] NM_001287049 SAXO1 Silent rs7022613 9 19051208 [T/C] rs7031392 9 19053247 [T/C] NM_017645,NM_001270890 HAUS6,HAUS6 EXON Silent,Silent rs10511671 9 19058821 [A/G] NM_017645,NM_001270890 HAUS6,HAUS6 EXON Synonymous_F648F,Synonymous_F613F rs4977494 9 19059678 [A/G] NM_017645,NM_001270890 HAUS6,HAUS6 Silent,Silent rs7467618 9 19065295 [T/C] NM_017645,NM_001270890 HAUS6,HAUS6 Silent,Silent rs10811110 9 19069911 [T/C] NM_017645,NM_001270890 HAUS6,HAUS6 Silent,Silent rs17238021 9 19074740 [A/G] NM_017645,NM_001270890 HAUS6,HAUS6 Silent,Silent rs10963938 9 19074820 [T/C] NM_017645,NM_001270890 HAUS6,HAUS6 Silent,Silent rs10963949 9 19084444 [T/G] NM_017645,NM_001270890 HAUS6,HAUS6 Silent,Silent rs2171957 9 19086979 [T/C] NM_017645,NM_001270890 HAUS6,HAUS6 Silent,Silent rs7860122 9 19087429 [A/G] NM_017645,NM_001270890 HAUS6,HAUS6 Silent,Silent rs7467137 9 19091387 [T/C] NM_017645,NM_001270890 HAUS6,HAUS6 Silent,Silent rs6415731 9 19098712 [A/G] NM_017645,NM_001270890 HAUS6,HAUS6 Silent,Silent rs7865126 9 19102828 [T/C] NM_017645,NM_001270890 HAUS6,HAUS6 EXON Silent,Silent rs12554335 9 19108827 [A/G] rs12338361 9 19111637 [T/C] rs12237614 9 19115088 [T/C] rs2229536 9 19116543 [A/G] NM_001122,NR_038064 PLIN2,PLIN2 EXON Synonymous_I339I,Silent rs3802335 9 19126476 [T/C] NM_001122,NR_038064 PLIN2,PLIN2 Silent,Silent rs3824369 9 19126565 [T/C] NM_001122,NR_038064 PLIN2,PLIN2 Silent,Silent rs3808657 9 19127877 [T/G] rs2046841 9 19132051 [A/G] rs10757028 9 19133732 [A/G] rs10963987 9 19142014 [A/C] rs10963994 9 19144191 [T/C] rs4977499 9 19145435 [A/G] rs882881 9 19149599 [A/G] rs4977502 9 19151845 [T/G] rs2451646 9 19152187 [A/G] rs10964006 9 19154572 [A/G] rs10964007 9 19155134 [T/C] rs3004297 9 19156784 [T/G] rs10964015 9 19161239 [A/G] rs3003715 9 19162016 [T/C] rs2503349 9 19163207 [T/C] rs13295225 9 19171247 [A/G] rs10964024 9 19174259 [T/C] rs10964025 9 19176406 [T/C] rs2503351 9 19182893 [A/G] rs13299148 9 19184484 [A/C] rs2451649 9 19186670 [T/C] rs13288647 9 19191447 [A/G] rs4977286 9 19192694 [T/C] rs12350228 9 19198294 [A/C] rs457062 9 19201738 [T/C] rs4262389 9 19205996 [T/C] rs461567 9 19206930 [T/C] rs4083651 9 19211852 [A/G] rs7846835 9 19219638 [A/C] rs10757033 9 19223304 [T/G] rs10123714 9 19231643 [T/C] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs4977291 9 19234830 [T/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs1329731 9 19234908 [A/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs1854551 9 19235270 [A/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs16937415 9 19236489 [A/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs4977517 9 19239168 [A/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs7027485 9 19244788 [A/C] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs10811150 9 19253268 [T/C] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs2383089 9 19258183 [A/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs10757049 9 19281501 [A/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs10122709 9 19290143 [T/C] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs7037101 9 19294397 [A/C] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs16937434 9 19297751 [A/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs7851902 9 19298581 [A/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs7044252 9 19299234 [T/C] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C EXON Missense_V372A,Missense_V372A,Silent rs7022273 9 19303086 [T/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs10757052 9 19308145 [T/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs13298053 9 19319689 [T/C] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs2256093 9 19326053 [T/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs11791904 9 19335160 [A/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs7849286 9 19343216 [A/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs2666797 9 19343291 [T/C] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs17818730 9 19346710 [A/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C EXON Missense_T1315A,Missense_T1266A,Silent rs6475322 9 19346941 [A/C] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C EXON Missense_N1392H,Missense_N1343H,Silent rs4578040 9 19359195 [A/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs7863119 9 19364042 [A/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs10114375 9 19370108 [T/G] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs10117525 9 19370343 [T/C] NM_001330640,NM_017925,NR_073201 DENND4C,DENND4C,DENND4C Silent,Silent,Silent rs10119465 9 19376144 [T/C] rs6475326 9 19386565 [T/C] rs12006065 9 19388116 [A/G] rs7048650 9 19397040 [A/G] rs12340464 9 19398565 [A/G] rs2383094 9 19400351 [T/C] rs4418423 9 19403973 [A/G] rs10757058 9 19419528 [T/C] NM_001010887 ACER2 Silent rs10118089 9 19420040 [T/C] NM_001010887 ACER2 Silent rs7039309 9 19426464 [T/C] NM_001010887 ACER2 Silent rs7023819 9 19426904 [A/G] NM_001010887 ACER2 Silent rs10125228 9 19428721 [A/G] NM_001010887 ACER2 Silent rs958841 9 19437713 [A/G] NM_001010887 ACER2 Silent rs10811184 9 19438279 [T/G] NM_001010887 ACER2 Silent rs10964139 9 19442558 [A/G] NM_001010887 ACER2 Silent rs10757059 9 19446663 [A/C] NM_001010887 ACER2 Silent rs12343276 9 19451807 [A/C] NM_001010887 ACER2 EXON Silent rs7022373 9 19452990 [T/C] rs7045369 9 19454906 [A/G] rs7027520 9 19457585 [A/G] rs960908 9 19458939 [T/C] rs12336251 9 19465900 [A/C] rs7021552 9 19468530 [T/G] rs10964151 9 19468696 [A/G] rs10964155 9 19469713 [T/C] rs11790131 9 19469846 [T/G] rs10964157 9 19470147 [T/C] rs12335928 9 19470804 [A/G] rs11792752 9 19472460 [A/C] rs10964160 9 19472784 [A/G] rs17566007 9 19476532 [T/C] rs6475332 9 19477947 [A/G] rs12346257 9 19478972 [T/C] rs7045446 9 19479033 [T/C] rs10121834 9 19479201 [T/C] rs7046383 9 19479536 [T/G] rs10964178 9 19486059 [A/G] rs10117909 9 19492973 [A/G] rs4977544 9 19509905 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 EXON Silent,Silent rs7864646 9 19510856 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 EXON Silent,Silent rs7867513 9 19511096 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 EXON Silent,Silent rs4977545 9 19512746 [T/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 EXON Silent,Silent rs7022987 9 19514307 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 EXON Silent,Silent rs2225143 9 19517795 [T/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs4977303 9 19523984 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs4977547 9 19526674 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs4977548 9 19526712 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs2209802 9 19528751 [A/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs3780218 9 19531262 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs10811199 9 19532826 [T/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs10738542 9 19551434 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs1006240 9 19551907 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs4977557 9 19554109 [T/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs16937601 9 19555377 [T/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs12340099 9 19556699 [A/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs12349316 9 19556835 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs7036497 9 19570345 [T/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs731407 9 19572704 [A/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs12684123 9 19575310 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs11790824 9 19576362 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs2383101 9 19576949 [T/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 EXON Synonymous_R401R,Synonymous_R384R rs3780215 9 19579427 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs7848995 9 19582883 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs10811214 9 19586463 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs2383103 9 19591153 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs2209797 9 19591691 [T/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs9792664 9 19593235 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs1885219 9 19598020 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs12000488 9 19598186 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs10964233 9 19599114 [T/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs10964234 9 19600362 [T/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs2180940 9 19604078 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs2180939 9 19606810 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs10964236 9 19608329 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs4977230 9 19613009 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs2208552 9 19614952 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs4977308 9 19622268 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 EXON Synonymous_P320P,Synonymous_P320P rs10757082 9 19623126 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs718623 9 19628633 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs12686805 9 19635062 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs10811219 9 19637920 [A/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs16937677 9 19642563 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs2208553 9 19645715 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs2208554 9 19646058 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs7870850 9 19649738 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs16937678 9 19652765 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs16937679 9 19652826 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs17492143 9 19655267 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs16937690 9 19656396 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs10738546 9 19657975 [A/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs4977232 9 19659564 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs4977233 9 19659652 [A/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs7045004 9 19660187 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs766576 9 19660406 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs12686758 9 19661573 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs2208557 9 19661935 [A/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs7040903 9 19666510 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs7035054 9 19668550 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs2383113 9 19678269 [A/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs13299310 9 19682676 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs1885233 9 19690739 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs13287081 9 19692697 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs12682926 9 19696452 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs7862478 9 19698751 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs12000690 9 19700975 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs7869055 9 19705396 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs7869360 9 19712170 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs7855757 9 19712378 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs12000054 9 19713500 [T/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs2208549 9 19728716 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs1182653 9 19729664 [T/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs1182654 9 19731896 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs1182657 9 19733052 [A/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs1182665 9 19736871 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs10757087 9 19740788 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs10964263 9 19742145 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs957910 9 19746160 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs11790276 9 19751159 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs1182672 9 19751357 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs1327407 9 19752860 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs10514825 9 19754476 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs11788522 9 19755034 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs16937762 9 19756086 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs1007910 9 19758207 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs1007907 9 19760153 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs6475366 9 19769000 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs1327409 9 19771890 [T/C] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs4977324 9 19779172 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 Silent,Silent rs1536517 9 19786217 [A/G] NM_020344,NM_001193288 SLC24A2,SLC24A2 EXON Synonymous_I216I,Synonymous_I216I rs1409954 9 19787182 [A/G] rs2383122 9 19787952 [A/G] rs3808653 9 19788166 [A/G] rs1409955 9 19790795 [T/C] rs1831083 9 19792882 [A/G] rs1327413 9 19797850 [A/G] rs10811244 9 19801918 [T/G] rs10811245 9 19803724 [A/G] rs3928332 9 19826404 [T/C] rs1536521 9 19827259 [T/C] rs10811249 9 19832327 [A/G] rs7032894 9 19840697 [A/G] rs10757097 9 19841897 [A/G] rs4977333 9 19842235 [A/C] rs713168 9 19847234 [A/C] rs4977334 9 19849403 [T/C] rs7849437 9 19857154 [T/C] rs10964321 9 19867614 [A/C] rs1576043 9 19868092 [A/C] rs1327404 9 19877230 [T/G] rs16937811 9 19879349 [T/C] rs7025940 9 19881264 [T/C] rs7026700 9 19881812 [T/C] rs12377344 9 19881986 [T/C] rs7030078 9 19882045 [T/C] rs10811261 9 19882156 [A/G] rs1857438 9 19882454 [T/C] rs10964323 9 19883421 [T/C] rs2051134 9 19889326 [A/C] rs1539683 9 19897119 [T/C] rs4977348 9 19897264 [T/C] rs10811278 9 19898792 [A/G] rs10757104 9 19901220 [T/C] rs2383131 9 19902822 [T/C] rs1887393 9 19903133 [T/C] rs10738554 9 19904103 [T/C] rs16937827 9 19912414 [A/G] rs10811281 9 19913075 [T/C] rs1419258 9 19914792 [A/G] rs10964340 9 19918297 [T/C] rs7852773 9 19919331 [T/C] rs17832714 9 19932591 [A/C] rs10811285 9 19937440 [A/C] rs12338019 9 19938527 [A/G] rs10811286 9 19939119 [T/G] rs10811288 9 19939469 [A/G] rs1573224 9 19942311 [T/C] rs9774948 9 19942824 [T/C] rs7869796 9 19946627 [T/C] rs7035925 9 19948964 [A/G] rs7039172 9 19949350 [A/C] rs7021102 9 19950818 [T/C] rs10964353 9 19951575 [T/C] rs9407950 9 19958389 [A/C] rs9407951 9 19959158 [A/G] rs7863041 9 19969904 [T/C] rs9406760 9 19971287 [T/C] rs10116300 9 19974894 [A/G] rs9406764 9 19979174 [T/C] rs2154091 9 19979623 [T/C] rs1936451 9 19987053 [T/C] rs7872451 9 19989693 [T/C] rs9406768 9 19994895 [A/G] rs12057077 9 20000600 [A/C] rs7862804 9 20001782 [A/C] rs7037807 9 20005312 [T/C] rs6475389 9 20005735 [T/C] rs1112017 9 20006704 [A/G] rs1892014 9 20014872 [T/C] rs4977370 9 20016698 [T/C] rs4977371 9 20016778 [T/C] rs7860695 9 20021047 [T/C] rs10964389 9 20022425 [T/C] rs10811299 9 20022680 [T/C] rs10964392 9 20025247 [A/C] rs10964393 9 20027231 [A/C] rs10964394 9 20028769 [C/G] rs10964396 9 20030553 [T/G] rs7851611 9 20031656 [T/C] rs12341973 9 20032728 [T/C] rs4246835 9 20033087 [A/G] rs6475394 9 20033977 [T/C] rs9792640 9 20035279 [A/G] rs9792484 9 20035364 [T/C] rs10964399 9 20038436 [A/G] rs7041787 9 20039441 [A/G] rs10964401 9 20045332 [T/G] rs12348353 9 20046681 [A/C] rs7026909 9 20048229 [T/C] rs12684532 9 20058939 [T/G] rs10964409 9 20059283 [T/G] rs7020837 9 20064974 [A/G] rs7037514 9 20068518 [T/C] rs4977378 9 20072686 [A/C] rs4246838 9 20072967 [A/G] rs3933328 9 20083157 [A/G] rs12342499 9 20084210 [A/G] rs4977384 9 20084264 [A/G] rs2383134 9 20093557 [A/G] rs10811316 9 20095103 [A/G] rs7871772 9 20096390 [T/C] rs5025178 9 20097117 [T/C] rs951303 9 20101645 [A/G] rs1333787 9 20111554 [T/C] rs10811319 9 20123538 [A/C] rs950020 9 20124467 [A/C] rs10964441 9 20131746 [A/G] rs7855796 9 20136893 [A/C] rs4977246 9 20144936 [T/C] rs2039461 9 20145988 [T/C] rs994975 9 20153762 [T/G] rs7019466 9 20159208 [A/G] rs7863754 9 20168739 [T/C] rs11562206 9 20171664 [T/C] rs7870612 9 20175694 [A/G] rs4478647 9 20176715 [A/G] rs1413254 9 20178680 [T/C] rs869149 9 20179356 [A/C] rs10738560 9 20180241 [T/G] rs1889245 9 20180613 [T/C] rs1889246 9 20180680 [T/C] rs13284316 9 20186459 [T/C] rs321205 9 20187462 [A/G] rs1889247 9 20187574 [T/C] rs1413255 9 20188704 [T/C] rs4977390 9 20190821 [T/C] rs4556171 9 20190838 [A/G] rs1456959 9 20196466 [T/C] rs403468 9 20209017 [T/C] rs415026 9 20209723 [A/G] rs1333790 9 20209879 [T/C] rs10964477 9 20216063 [T/C] rs2034875 9 20219315 [A/G] rs7027828 9 20224476 [A/G] rs10511678 9 20238152 [A/G] rs10964494 9 20239894 [T/C] rs7867635 9 20241069 [T/C] rs7853226 9 20241907 [A/G] rs1379216 9 20244920 [T/C] rs7046901 9 20246894 [A/G] rs10964496 9 20248264 [A/G] rs1456962 9 20250993 [T/G] rs1379219 9 20251081 [A/G] rs7049073 9 20252120 [A/C] rs7049230 9 20252271 [A/G] rs7039444 9 20253425 [T/C] rs1551534 9 20255355 [A/G] rs4977400 9 20255922 [A/G] rs7018634 9 20259528 [A/C] rs4977404 9 20260160 [A/G] rs12345147 9 20262063 [A/C] rs4977406 9 20267556 [A/G] rs13287033 9 20269201 [T/C] rs7848583 9 20270393 [A/G] rs1551535 9 20270444 [A/C] rs4977407 9 20270528 [T/G] rs1456961 9 20271492 [T/G] rs1031602 9 20272411 [T/C] rs13440226 9 20272442 [T/C] rs1840789 9 20273783 [T/C] rs7019257 9 20273793 [T/C] rs10811339 9 20274450 [T/C] rs4146635 9 20274698 [A/G] rs7868882 9 20275143 [A/G] rs12683533 9 20282519 [A/C] rs10811340 9 20283406 [A/G] rs10811342 9 20285162 [A/C] rs12353526 9 20286678 [T/C] rs717081 9 20287139 [T/C] rs717082 9 20287282 [A/G] rs7867670 9 20287612 [A/G] rs7026582 9 20287948 [T/C] rs882123 9 20289153 [A/G] rs897703 9 20289426 [T/C] rs10757131 9 20292245 [A/G] rs7021788 9 20295863 [A/G] rs12341095 9 20301704 [A/G] rs17262780 9 20304873 [T/G] rs16938009 9 20308956 [A/G] rs224025 9 20309831 [T/C] rs224022 9 20313099 [A/G] rs224018 9 20316240 [T/C] rs7023422 9 20318797 [A/G] rs7044062 9 20319623 [T/G] rs224016 9 20322257 [T/C] rs7048991 9 20322932 [T/C] rs224015 9 20323424 [T/C] rs224008 9 20324812 [T/C] rs10964534 9 20327754 [A/G] rs3739934 9 20331681 [A/G] rs10435776 9 20333293 [T/C] rs16938023 9 20336146 [A/G] rs7856579 9 20337131 [A/G] rs3824576 9 20341702 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 EXON Silent,Silent rs4977421 9 20341734 [A/C] NM_004529,NM_001286691 MLLT3,MLLT3 EXON Silent,Silent rs10964538 9 20342044 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 EXON Silent,Silent rs10757132 9 20342556 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 EXON Silent,Silent rs7862166 9 20347240 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs7866409 9 20350254 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs7870252 9 20351075 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs7037813 9 20353227 [T/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs2301548 9 20354575 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs2301550 9 20354796 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs7866741 9 20357805 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs7847028 9 20361231 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10453171 9 20379884 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs1413554 9 20391116 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10964552 9 20405630 [A/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs16938058 9 20411354 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10811349 9 20418323 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs7041793 9 20428137 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs6475430 9 20430468 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs16938065 9 20455616 [T/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs4977256 9 20464018 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs3904577 9 20464362 [A/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10964566 9 20465928 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs12344417 9 20469336 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs3934325 9 20471312 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs12350051 9 20475176 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs12003960 9 20477061 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs3893395 9 20478188 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs6475434 9 20482380 [A/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs6475438 9 20484509 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs6475439 9 20484604 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs6475448 9 20497142 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs1411726 9 20498930 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs1411727 9 20498974 [T/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10964583 9 20508503 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10811359 9 20514400 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs12682705 9 20518923 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs7868240 9 20519521 [T/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs7854782 9 20521543 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10757135 9 20527695 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs1537073 9 20528546 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10117696 9 20533643 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs11792012 9 20542139 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10964600 9 20549744 [A/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs4977427 9 20551111 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs1111766 9 20553571 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs1537069 9 20560683 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs1360378 9 20563799 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs12380857 9 20578041 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10811371 9 20581841 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10811372 9 20581910 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10757140 9 20585867 [A/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs12006514 9 20587397 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs7025895 9 20590209 [A/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs6475464 9 20597576 [A/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs636100 9 20599426 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs668703 9 20601177 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs2775264 9 20603364 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10964636 9 20605854 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs623828 9 20606428 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs2780840 9 20608377 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs2188230 9 20608912 [T/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10115725 9 20610476 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs2780839 9 20610914 [A/C] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs10811376 9 20617114 [A/G] NM_004529,NM_001286691 MLLT3,MLLT3 Silent,Silent rs2073854 9 20623446 [T/G] rs2519454 9 20625228 [A/G] rs2188229 9 20625875 [A/G] rs2780838 9 20629336 [T/C] rs1548378 9 20629553 [A/C] rs1548377 9 20631633 [T/C] rs1889225 9 20636973 [T/C] rs6475467 9 20638248 [T/C] rs2383141 9 20641181 [A/C] rs10811380 9 20641792 [T/C] rs4129311 9 20642438 [T/C] rs6475468 9 20648623 [A/G] rs10811383 9 20652174 [A/G] rs7859426 9 20665071 [T/C] NM_017794 FOCAD Silent rs4596728 9 20670187 [A/G] NM_017794 FOCAD Silent rs7872857 9 20670573 [A/G] NM_017794 FOCAD Silent rs7867822 9 20676454 [A/G] NM_017794 FOCAD Silent rs10964662 9 20690387 [A/G] NM_017794 FOCAD Silent rs10964665 9 20700838 [A/G] NM_017794 FOCAD Silent rs1332311 9 20701305 [T/G] NM_017794 FOCAD Silent rs1332312 9 20703928 [A/G] NM_017794 FOCAD Silent rs10811394 9 20704320 [T/C] NM_017794 FOCAD Silent rs17832026 9 20704772 [T/C] NM_017794 FOCAD Silent rs1930050 9 20710798 [A/G] NM_017794 FOCAD Silent rs12376200 9 20710896 [A/G] NM_017794 FOCAD Silent rs16938133 9 20711350 [T/C] NM_017794 FOCAD Silent rs2039391 9 20714014 [T/C] NM_017794 FOCAD Silent rs12684948 9 20716880 [T/C] NM_017794 FOCAD Silent rs12683110 9 20717020 [A/G] NM_017794 FOCAD Silent rs7046563 9 20723087 [A/C] NM_017794 FOCAD Silent rs1888920 9 20726571 [T/G] NM_017794 FOCAD Silent rs1556476 9 20735234 [A/G] NM_017794 FOCAD Silent rs10511689 9 20737847 [A/C] NM_017794 FOCAD Silent rs7031527 9 20739042 [A/G] NM_017794 FOCAD Silent rs7030093 9 20740671 [T/C] NM_017794 FOCAD Silent rs7034088 9 20741355 [T/C] NM_017794 FOCAD Silent rs883601 9 20742770 [T/C] NM_017794 FOCAD Silent rs914605 9 20742963 [A/G] NM_017794 FOCAD Silent rs7043296 9 20747070 [A/G] NM_017794 FOCAD Silent rs1332322 9 20749871 [A/C] NM_017794 FOCAD Silent rs17685780 9 20754419 [T/C] NM_017794 FOCAD Silent rs1475660 9 20756547 [A/G] NM_017794 FOCAD Silent rs10964685 9 20756763 [A/G] NM_017794 FOCAD Silent rs17832189 9 20762926 [T/C] NM_017794 FOCAD Silent rs16938162 9 20763840 [T/C] NM_017794 FOCAD Silent rs10511687 9 20764870 [T/C] NM_017794 FOCAD EXON Missense_L166S rs10811399 9 20766254 [A/G] NM_017794 FOCAD Silent rs10441706 9 20770031 [A/G] NM_017794 FOCAD EXON Missense_V234I rs10964692 9 20771153 [A/G] NM_017794 FOCAD Silent rs12551126 9 20776743 [A/C] NM_017794 FOCAD Silent rs4978125 9 20779843 [T/C] NM_017794 FOCAD Silent rs7027599 9 20782100 [T/C] NM_017794 FOCAD Silent rs17685984 9 20786691 [A/G] NM_017794 FOCAD Silent rs10964702 9 20789869 [A/G] NM_017794 FOCAD Silent rs7036612 9 20793269 [A/G] NM_017794 FOCAD Silent rs10964709 9 20801654 [A/G] NM_017794 FOCAD Silent rs10511682 9 20811421 [A/G] NM_017794 FOCAD Silent rs17832431 9 20820329 [A/G] NM_017794 FOCAD EXON Missense_I523V rs1556475 9 20821287 [T/C] NM_017794 FOCAD Silent rs3898946 9 20822078 [A/G] NM_017794 FOCAD Silent rs17759424 9 20823314 [A/C] NM_017794 FOCAD Silent rs7851807 9 20825682 [A/G] NM_017794 FOCAD Silent rs2026994 9 20834837 [A/G] NM_017794 FOCAD Silent rs7870627 9 20840838 [A/G] NM_017794 FOCAD Silent rs4977780 9 20862515 [A/C] NM_017794 FOCAD Silent rs10964742 9 20866982 [A/G] NM_017794 FOCAD EXON Missense_E721K rs2383154 9 20867809 [A/G] NM_017794 FOCAD Silent rs2383155 9 20868172 [A/G] NM_017794 FOCAD Silent rs11789503 9 20872842 [T/C] NM_017794 FOCAD Silent rs1986633 9 20876259 [A/G] NM_017794 FOCAD Silent rs1986632 9 20876513 [A/C] NM_017794 FOCAD Silent rs2891154 9 20883241 [T/C] NM_017794 FOCAD Silent rs7044578 9 20886882 [T/C] NM_017794 FOCAD Silent rs10811422 9 20890466 [A/G] NM_017794 FOCAD Silent rs7853915 9 20891171 [A/G] NM_017794 FOCAD Silent rs12236288 9 20898233 [T/C] NM_017794 FOCAD Silent rs4288451 9 20908374 [A/G] NM_017794 FOCAD Silent rs12375887 9 20910537 [T/C] NM_017794 FOCAD Silent rs7044452 9 20923579 [T/C] NM_017794 FOCAD Silent rs10964759 9 20925921 [A/G] NM_017794 FOCAD Silent rs9406776 9 20928323 [T/C] NM_017794 FOCAD Silent rs9407968 9 20929977 [A/C] NM_017794 FOCAD Silent rs2383171 9 20932868 [T/G] NM_017794 FOCAD Silent rs12552707 9 20944558 [A/G] NM_017794 FOCAD Silent rs3206852 9 20953049 [A/G] NM_017794 FOCAD EXON Missense_T1373A rs4977848 9 20953750 [A/G] NM_017794 FOCAD Silent rs10964769 9 20963374 [A/G] NM_017794 FOCAD Silent rs7873691 9 20966250 [T/C] NM_017794 FOCAD Silent rs4977863 9 20975121 [A/G] NM_017794 FOCAD Silent rs10811445 9 20978306 [A/G] NM_017794 FOCAD Silent rs10738571 9 20994176 [T/C] NM_017794 FOCAD Silent rs10757171 9 20998354 [A/G] rs4278230 9 20999646 [A/G] rs12004236 9 21002225 [A/C] rs3884620 9 21003372 [A/G] rs4129714 9 21005744 [T/C] NM_001321883,NM_001010915,NM_001321903 HACD4,HACD4,HACD4 EXON Silent,Silent,Silent rs1134090 9 21006934 [A/G] NM_001321883,NM_001010915,NM_001321903 HACD4,HACD4,HACD4 EXON Silent,Silent,Silent rs7041474 9 21007935 [A/G] NM_001321883,NM_001010915,NM_001321903 HACD4,HACD4,HACD4 Silent,Silent,Silent rs10511697 9 21011722 [A/G] NM_001321883,NM_001010915,NM_001321903 HACD4,HACD4,HACD4 Silent,Silent,Silent rs7873640 9 21015651 [T/G] NM_001321883,NM_001010915,NM_001321903 HACD4,HACD4,HACD4 Silent,Silent,Silent rs2275886 9 21017743 [T/C] NM_001321883,NM_001010915,NM_001321903 HACD4,HACD4,HACD4 Silent,Silent,Silent rs2275887 9 21017828 [A/G] NM_001321883,NM_001010915,NM_001321903 HACD4,HACD4,HACD4 Silent,Silent,Silent rs2275888 9 21017884 [T/C] NM_001321883,NM_001010915,NM_001321903 HACD4,HACD4,HACD4 Silent,Silent,Silent rs7874876 9 21019817 [T/C] NM_001321883,NM_001010915,NM_001321903 HACD4,HACD4,HACD4 Silent,Silent,Silent rs2298260 9 21029330 [T/C] NM_001321883,NM_001010915,NM_001321903 HACD4,HACD4,HACD4 EXON Silent,Missense_T36A,Missense_T36A rs10738578 9 21037771 [T/C] rs10811457 9 21046482 [T/G] rs10757178 9 21046674 [T/C] rs17692145 9 21046790 [T/G] rs7033704 9 21051966 [A/C] rs10964817 9 21056085 [T/C] rs1539741 9 21058908 [A/G] rs1539743 9 21059531 [A/G] rs1857651 9 21060974 [T/C] rs2383176 9 21061642 [A/G] rs10811460 9 21062144 [A/G] rs1539744 9 21065299 [A/G] rs1424860 9 21073945 [T/C] rs10811464 9 21076087 [A/G] rs1051922 9 21077716 [A/G] NM_002176 IFNB1 EXON Synonymous_Y51Y rs9333358 9 21078952 [T/C] rs10811465 9 21080518 [T/C] rs10811466 9 21082814 [T/C] rs10757181 9 21093083 [A/C] rs4977948 9 21094151 [T/G] rs17692260 9 21094833 [A/G] rs10964832 9 21095633 [T/C] rs10757182 9 21097135 [A/G] rs12349659 9 21098843 [A/G] rs10757183 9 21099471 [T/G] rs1892130 9 21102280 [T/C] rs10757184 9 21105078 [A/G] rs4977959 9 21105154 [A/G] rs11795225 9 21106901 [A/G] rs2113718 9 21108817 [A/G] rs2032061 9 21114105 [A/G] rs10811474 9 21114237 [A/G] rs1364614 9 21115002 [A/G] rs4255228 9 21117059 [A/G] rs9886796 9 21121917 [A/G] rs1016129 9 21122681 [A/G] rs10964854 9 21129246 [A/G] rs1593270 9 21129719 [A/G] rs7854237 9 21132664 [A/G] rs7029734 9 21133196 [A/G] rs1345975 9 21139896 [T/C] rs10757189 9 21142604 [A/G] rs7046606 9 21149963 [T/C] rs7855438 9 21150650 [A/C] rs17759921 9 21151016 [T/C] rs10964862 9 21151553 [A/C] rs10811482 9 21153985 [A/G] rs10757193 9 21157373 [A/G] rs10283629 9 21157695 [A/G] rs10964871 9 21163761 [A/G] rs2939 9 21166004 [A/G] NM_002175 IFNA21 EXON Silent rs7037868 9 21170595 [A/G] rs7022884 9 21177609 [T/G] rs1477478 9 21178332 [T/C] rs2019226 9 21179174 [A/G] rs2007448 9 21196356 [A/G] rs12348971 9 21198384 [A/C] rs4977686 9 21199680 [T/G] rs7019230 9 21203153 [T/C] rs2015345 9 21214877 [T/G] rs9333362 9 21215326 [A/G] rs3919593 9 21216728 [T/C] NM_002173 IFNA16 EXON Silent rs12004698 9 21226832 [A/G] rs7033839 9 21234721 [A/G] rs4628333 9 21238962 [A/G] rs1330320 9 21255150 [A/G] rs1475547 9 21285389 [T/C] rs1330311 9 21289069 [T/C] rs4978097 9 21294921 [A/G] rs10120117 9 21295318 [A/G] rs1330312 9 21295828 [T/C] rs4978107 9 21300864 [A/G] rs7021906 9 21304057 [A/G] rs28383775 9 21304245 [A/G] rs12156640 9 21306241 [A/G] rs7031048 9 21306318 [A/G] rs10117202 9 21323089 [T/G] rs913931 9 21327141 [A/G] rs16938346 9 21332295 [A/C] NM_018847 KLHL9 EXON Silent rs7863385 9 21335404 [A/C] NM_018847 KLHL9 EXON Silent rs16938347 9 21337927 [T/C] rs10119678 9 21340786 [A/C] rs614541 9 21352862 [T/C] rs597408 9 21361957 [A/G] rs2480927 9 21366894 [T/C] rs596180 9 21370864 [T/C] rs13286246 9 21371264 [A/G] rs647167 9 21381286 [T/G] rs615544 9 21383734 [A/C] rs10120977 9 21384363 [A/G] NM_000605 IFNA2 EXON Silent rs1224391 9 21391698 [T/C] rs591537 9 21395611 [T/C] rs10121687 9 21397773 [T/C] rs10757218 9 21398147 [A/G] rs16938383 9 21398625 [A/G] rs4978113 9 21401106 [T/C] rs16938392 9 21403636 [A/G] rs10757219 9 21405363 [A/G] rs16938396 9 21410090 [T/C] NM_002170 IFNA8 EXON Silent rs16938398 9 21411213 [T/C] rs9333353 9 21411631 [A/G] rs1332180 9 21413085 [A/G] rs7025006 9 21415687 [A/G] rs2104880 9 21419723 [T/C] rs1332179 9 21420677 [A/G] rs1591032 9 21423520 [T/C] rs7043990 9 21428770 [T/C] rs16938360 9 21435859 [T/C] rs1332190 9 21438684 [A/G] rs10491569 9 21456776 [A/G] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs16938422 9 21470520 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs7861480 9 21470997 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs2383192 9 21471726 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs2039381 9 21481483 [A/G] NR_152877,NR_027054,NR_152879,NR_152878,NM_176891 MIR31HG,MIR31HG,MIR31HG,MIR31HG,IFNE EXON Silent,Silent,Silent,Silent,Nonsense_Q71X rs1125488 9 21481556 [T/G] NR_152877,NR_027054,NR_152879,NR_152878,NM_176891 MIR31HG,MIR31HG,MIR31HG,MIR31HG,IFNE EXON Silent,Silent,Silent,Silent,Missense_Q46H rs10757222 9 21485974 [T/G] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs12554691 9 21492506 [A/G] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs4978121 9 21494300 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs2383194 9 21497120 [T/G] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs7849575 9 21499793 [A/G] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs4977726 9 21503812 [T/G] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs17729561 9 21503821 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs1332184 9 21504203 [A/G] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs7848909 9 21504973 [A/G] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs1537279 9 21506118 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs1537276 9 21506356 [T/G] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs1332183 9 21506986 [A/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs1537275 9 21507589 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs10491566 9 21516772 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs7026731 9 21519921 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs10811561 9 21530609 [A/G] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs2025327 9 21531629 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs12379721 9 21536423 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs10811568 9 21543444 [A/G] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs16938456 9 21547035 [A/G] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs7863623 9 21548586 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs991794 9 21551513 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs991792 9 21551647 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs1983810 9 21552654 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs1983811 9 21553004 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs9298816 9 21555283 [T/C] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs10757225 9 21555445 [T/G] NR_152877,NR_027054,NR_152879,NR_152878 MIR31HG,MIR31HG,MIR31HG,MIR31HG Silent,Silent,Silent,Silent rs7033598 9 21565674 [T/C] rs7865428 9 21566730 [A/G] rs1452653 9 21573016 [T/C] rs12685827 9 21580763 [T/C] rs7026552 9 21581712 [T/G] rs1542302 9 21588969 [A/G] rs2123340 9 21589041 [A/G] rs7032413 9 21598941 [T/C] rs12343168 9 21600424 [A/G] rs16938476 9 21601758 [T/C] rs16938481 9 21604067 [A/G] rs10965079 9 21604969 [A/G] rs12115747 9 21606566 [A/C] rs7855418 9 21606786 [T/C] rs7848640 9 21611256 [T/C] rs10123003 9 21620510 [T/G] rs10491562 9 21626200 [A/G] rs754819 9 21626573 [T/G] rs13297146 9 21626953 [T/C] rs7862733 9 21632534 [T/C] rs10115623 9 21638846 [A/G] rs13294794 9 21638902 [A/G] rs10757227 9 21641325 [T/G] rs10757229 9 21642590 [A/G] rs11788139 9 21651620 [T/C] rs16938501 9 21653928 [A/G] rs10491561 9 21658399 [A/G] rs13287480 9 21658652 [A/G] rs4512473 9 21663040 [A/G] rs12342723 9 21670461 [T/C] rs10120643 9 21672769 [A/G] rs16938525 9 21673461 [A/G] rs10965097 9 21674425 [T/C] rs1869203 9 21674949 [T/C] rs2039585 9 21675373 [A/C] rs1377195 9 21675545 [A/G] rs10965099 9 21682759 [A/G] rs16938544 9 21683198 [A/C] rs7860632 9 21683289 [A/C] rs7865502 9 21684722 [A/G] rs1869204 9 21690958 [T/G] rs12380505 9 21695893 [A/G] rs7848524 9 21701432 [T/C] rs10811586 9 21701942 [T/G] rs7874607 9 21704498 [A/G] rs896655 9 21706571 [A/G] rs2210779 9 21721615 [A/G] rs10123637 9 21721939 [T/G] rs6475564 9 21728683 [T/C] rs1335503 9 21737822 [A/G] rs1345026 9 21745756 [T/C] rs4636294 9 21747803 [A/G] rs7866787 9 21760639 [A/G] rs1414259 9 21764086 [A/C] rs7037577 9 21772037 [A/G] rs7037277 9 21772064 [A/G] rs10811615 9 21782164 [A/G] rs12380373 9 21795661 [A/G] rs7865829 9 21797135 [T/C] rs1440994 9 21801319 [T/C] rs7871477 9 21810531 [T/G] NM_002451 MTAP Silent rs6475584 9 21811027 [T/C] NM_002451 MTAP Silent rs10811624 9 21812720 [T/C] NM_002451 MTAP Silent rs2039971 9 21815166 [T/G] NM_002451 MTAP Silent rs7023329 9 21816528 [A/G] NM_002451 MTAP Silent rs7023954 9 21816758 [A/G] NM_002451 MTAP EXON Missense_V56I rs3928894 9 21818310 [T/C] NM_002451 MTAP Silent rs7867176 9 21825996 [A/G] NM_002451 MTAP Silent rs7029287 9 21826387 [T/C] NM_002451 MTAP Silent rs1544195 9 21830479 [A/G] NM_002451 MTAP Silent rs12349004 9 21833883 [A/G] NM_002451 MTAP Silent rs10811629 9 21840298 [A/G] NM_002451 MTAP Silent rs7850937 9 21846285 [A/G] NM_002451 MTAP Silent rs7851133 9 21846327 [T/C] NM_002451 MTAP Silent rs4478653 9 21853221 [T/C] NM_002451 MTAP Silent rs4636295 9 21854199 [A/G] NM_002451 MTAP Silent rs10965163 9 21854740 [T/C] NM_002451 MTAP EXON Synonymous_R187R rs3802393 9 21855038 [A/G] NM_002451 MTAP Silent rs7871127 9 21856777 [T/C] NM_002451 MTAP Silent rs7047648 9 21857244 [A/G] NM_002451 MTAP Silent rs7047899 9 21857303 [T/C] NM_002451 MTAP Silent rs4129861 9 21861552 [T/C] NM_002451 MTAP Silent rs10117507 9 21864098 [A/G] NM_002451 MTAP EXON Silent rs3802394 9 21864535 [A/G] NM_002451 MTAP EXON Silent rs6475592 9 21865842 [T/C] NM_002451 MTAP EXON Silent rs4607709 9 21881338 [T/C] rs756641 9 21902354 [A/C] rs16938590 9 21909979 [A/G] rs10811635 9 21910698 [A/G] rs4977746 9 21920346 [T/C] rs7852128 9 21925855 [T/G] rs10965187 9 21930505 [A/G] rs12003027 9 21934442 [T/C] rs7875199 9 21936381 [T/C] rs4977750 9 21944317 [A/C] rs4382559 9 21944818 [A/G] rs10965197 9 21948666 [T/C] rs2518722 9 21952926 [T/C] rs7041637 9 21961866 [A/C] rs3731257 9 21966221 [A/G] rs3731249 9 21970916 [T/C] NM_001195132,NM_058197,NM_001363763,NM_058195,NM_000077 CDKN2A,CDKN2A,CDKN2A,CDKN2A,CDKN2A EXON Missense_A148T,Silent,Missense_A97T,Silent,Missense_A148T rs3731239 9 21974218 [A/G] NM_001195132,NM_058197,NM_001363763,NM_058195,NM_000077 CDKN2A,CDKN2A,CDKN2A,CDKN2A,CDKN2A Silent,Silent,Silent,Silent,Silent rs4074785 9 21981583 [A/G] NM_001363763,NM_058195 CDKN2A,CDKN2A Silent,Silent rs3731217 9 21984661 [A/C] NM_001363763,NM_058195 CDKN2A,CDKN2A Silent,Silent rs7036656 9 21990457 [T/C] NM_001363763,NM_058195 CDKN2A,CDKN2A Silent,Silent rs2811712 9 21998035 [A/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3218005 9 22000247 [T/C] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3217992 9 22003223 [T/C] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543,NM_004936,NM_078487 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B,CDKN2B EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1063192 9 22003367 [A/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543,NM_004936,NM_078487 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B,CDKN2B EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2285329 9 22004153 [A/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543,NM_004936,NM_078487 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B,CDKN2B EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3217986 9 22005330 [T/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543,NM_004936,NM_078487 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B,CDKN2B EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3217973 9 22009960 [A/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13298881 9 22012051 [T/C] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs545226 9 22012422 [A/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7049105 9 22028801 [A/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs564398 9 22029547 [T/C] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1333035 9 22044059 [A/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1333034 9 22044122 [T/C] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11790231 9 22053591 [A/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10120688 9 22056499 [A/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1011970 9 22062134 [T/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10811650 9 22067593 [A/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16905597 9 22068074 [A/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4977756 9 22068652 [A/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9632885 9 22072638 [A/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10757270 9 22072719 [A/G] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7855162 9 22074793 [T/C] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1412832 9 22077543 [T/C] NR_047542,NR_047541,NR_120536,NR_003529,NR_047539,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047540,NR_047533,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7855660 9 22078305 [T/C] NR_120536,NR_003529,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1547705 9 22082375 [A/C] NR_120536,NR_003529,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1333040 9 22083404 [T/C] NR_120536,NR_003529,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1537370 9 22084310 [T/C] NR_120536,NR_003529,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10757272 9 22088260 [T/C] NR_120536,NR_003529,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10757274 9 22096055 [A/G] NR_120536,NR_003529,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4977574 9 22098574 [A/G] NR_120536,NR_003529,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2891168 9 22098619 [A/G] NR_120536,NR_003529,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10965232 9 22101120 [T/C] NR_120536,NR_003529,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1333042 9 22103813 [A/G] NR_120536,NR_003529,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10738609 9 22114495 [A/G] NR_120536,NR_003529,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2383206 9 22115026 [A/G] NR_120536,NR_003529,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10965235 9 22115105 [A/C] NR_120536,NR_003529,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2383207 9 22115959 [A/G] NR_120536,NR_003529,NR_047535,NR_047534,NR_047536,NR_047537,NR_047538,NR_047532,NR_047543 CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1,CDKN2B-AS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10757281 9 22127613 [T/C] rs10811658 9 22128600 [A/G] rs10965243 9 22130065 [A/G] rs7045889 9 22133251 [A/G] rs10217762 9 22133645 [T/C] rs10811659 9 22133716 [T/C] rs10757282 9 22133984 [T/C] rs10757283 9 22134172 [T/C] rs7018475 9 22137685 [T/G] rs4977761 9 22138762 [T/C] rs2065501 9 22140224 [A/C] rs7854629 9 22141034 [A/G] rs7026735 9 22141269 [T/C] rs2065504 9 22141552 [T/G] rs2065505 9 22141790 [A/G] rs10811664 9 22142907 [A/G] rs7853656 9 22144530 [T/G] rs2065500 9 22145694 [A/G] rs10965256 9 22151465 [A/G] rs7853123 9 22153360 [A/G] rs944802 9 22155709 [T/C] rs1333052 9 22157908 [A/C] rs10757288 9 22159416 [T/C] rs10811667 9 22159982 [A/C] rs10965267 9 22161828 [T/G] rs10965269 9 22162061 [A/G] rs17694933 9 22164309 [A/G] rs10811668 9 22164991 [A/C] rs2779748 9 22166769 [T/C] rs10757292 9 22176961 [T/C] rs4977764 9 22184674 [T/C] rs2767409 9 22184997 [A/G] rs1095898 9 22189716 [T/C] rs1679029 9 22195321 [A/G] rs2219849 9 22195820 [T/C] rs12350824 9 22201586 [T/C] rs2025796 9 22202151 [A/G] rs1409772 9 22203800 [T/G] rs9696092 9 22206559 [T/C] rs1679013 9 22206987 [T/C] rs1679014 9 22207037 [T/C] rs12003808 9 22228560 [T/C] rs10811678 9 22228756 [T/C] rs7859353 9 22237616 [A/G] rs1679020 9 22245423 [A/G] rs1679022 9 22246794 [A/G] rs1679026 9 22272866 [A/G] rs11791293 9 22291214 [T/C] rs1609591 9 22291931 [A/C] rs10811685 9 22293804 [A/G] rs1575971 9 22301053 [T/C] rs1575973 9 22301383 [T/G] rs1327053 9 22321234 [A/G] rs12002955 9 22332474 [T/G] rs943394 9 22332703 [A/G] rs7856683 9 22333578 [T/C] rs716580 9 22336434 [A/G] rs1359741 9 22336954 [A/G] rs9406787 9 22340159 [T/C] rs10811697 9 22364080 [A/G] rs10757321 9 22379219 [T/G] rs944033 9 22380028 [A/G] rs944037 9 22382449 [T/C] rs4452893 9 22383816 [A/G] rs10811703 9 22385355 [A/G] rs16906022 9 22388891 [A/C] rs7024019 9 22392359 [T/C] rs9696718 9 22395664 [T/C] rs7024096 9 22399693 [T/C] rs10965342 9 22412570 [A/G] rs7875648 9 22417016 [A/G] rs7846900 9 22417552 [A/G] rs12554657 9 22423245 [A/G] rs10491848 9 22424834 [A/G] rs2891170 9 22426539 [A/G] rs16906084 9 22430804 [A/G] rs676417 9 22434723 [A/G] rs1576334 9 22442343 [T/C] rs596543 9 22442888 [T/C] rs693370 9 22446297 [A/G] rs655497 9 22446828 [A/G] rs563802 9 22451031 [A/G] NM_022160 DMRTA1 Silent rs17835669 9 22454125 [A/G] rs6475646 9 22454150 [A/G] rs10733377 9 22455518 [A/G] rs10738628 9 22456296 [A/G] rs665908 9 22460095 [A/C] rs7868400 9 22463201 [A/G] rs630871 9 22471418 [A/G] rs7039553 9 22471832 [T/C] rs16906189 9 22472068 [T/C] rs7027027 9 22472289 [T/G] rs12553590 9 22478447 [T/C] rs556958 9 22481286 [T/C] rs667115 9 22487177 [T/C] rs586716 9 22488678 [A/G] rs28808010 9 22492584 [T/C] rs7022740 9 22508807 [T/C] rs1392084 9 22510754 [A/G] rs17694987 9 22513603 [A/G] rs13284006 9 22518195 [T/G] rs2221132 9 22520468 [A/C] rs12000593 9 22523533 [A/G] rs10811719 9 22525505 [A/G] rs10965372 9 22527750 [A/C] rs7859900 9 22529933 [T/G] rs10738632 9 22531190 [A/G] rs10811721 9 22532249 [T/C] rs2891171 9 22535511 [T/C] rs10811723 9 22542285 [A/G] rs1948682 9 22543731 [A/G] rs1948678 9 22544607 [A/G] rs10811725 9 22544804 [T/C] rs4977586 9 22547508 [T/C] rs13289947 9 22551240 [A/G] rs1499543 9 22552659 [T/C] rs1158382 9 22554601 [A/G] rs9644863 9 22565072 [T/C] rs1499558 9 22583181 [T/C] rs10811743 9 22583561 [A/G] rs7469285 9 22596808 [T/C] rs10965398 9 22596867 [T/C] rs10217416 9 22598741 [A/G] rs10757346 9 22599344 [A/C] rs10965400 9 22607894 [T/C] rs11793406 9 22608275 [A/G] rs12350224 9 22612584 [T/G] rs10118516 9 22613796 [A/C] rs10757350 9 22614985 [A/G] rs2065846 9 22616426 [A/G] rs2065848 9 22617009 [A/G] rs1414696 9 22617269 [T/G] rs7024672 9 22619647 [A/G] rs10965404 9 22622698 [T/C] rs10965407 9 22624610 [A/G] rs1932605 9 22625034 [T/C] rs13290572 9 22625247 [A/G] rs7027641 9 22625577 [A/G] rs635827 9 22628385 [A/G] rs17695326 9 22634275 [A/G] rs1999760 9 22638990 [A/G] rs6475671 9 22639410 [T/G] rs10965408 9 22639567 [T/C] rs670126 9 22641126 [A/G] rs1448792 9 22641633 [A/G] rs1448789 9 22644110 [A/G] rs842837 9 22644806 [A/G] rs12553349 9 22648562 [T/C] NR_038977 LINC01239 Silent rs16906456 9 22652491 [A/G] NR_038977 LINC01239 Silent rs10965412 9 22653899 [T/G] NR_038977 LINC01239 Silent rs17695493 9 22658001 [T/C] NR_038977 LINC01239 Silent rs578315 9 22664213 [A/G] NR_038977 LINC01239 Silent rs12551699 9 22668988 [T/C] NR_038977 LINC01239 Silent rs2210865 9 22669166 [A/G] NR_038977 LINC01239 Silent rs842834 9 22673444 [T/C] NR_038977 LINC01239 Silent rs12350664 9 22690913 [A/G] NR_038977 LINC01239 Silent rs1619363 9 22699397 [T/C] NR_038977 LINC01239 Silent rs7859540 9 22700554 [T/G] NR_038977 LINC01239 Silent rs1375290 9 22706144 [A/G] NR_038977 LINC01239 Silent rs474342 9 22711948 [T/C] NR_038977 LINC01239 Silent rs565595 9 22724188 [A/G] NR_038977 LINC01239 Silent rs688581 9 22725295 [A/G] NR_038977 LINC01239 Silent rs593909 9 22730877 [A/C] NR_038977 LINC01239 Silent rs4133767 9 22731935 [A/G] NR_038977 LINC01239 Silent rs10125443 9 22739631 [T/C] NR_038977 LINC01239 Silent rs640648 9 22742136 [T/C] NR_038977 LINC01239 Silent rs842845 9 22746734 [A/C] NR_038977 LINC01239 Silent rs842846 9 22747274 [T/C] NR_038977 LINC01239 Silent rs842847 9 22748083 [A/C] NR_038977 LINC01239 Silent rs527427 9 22748466 [T/C] NR_038977 LINC01239 Silent rs644917 9 22749869 [A/G] NR_038977 LINC01239 Silent rs10123107 9 22754513 [A/G] NR_038977 LINC01239 Silent rs16906524 9 22755025 [A/G] NR_038977 LINC01239 Silent rs495897 9 22756708 [T/C] NR_038977 LINC01239 Silent rs4607705 9 22765106 [T/C] NR_038977 LINC01239 Silent rs505061 9 22767164 [A/C] NR_038977 LINC01239 Silent rs1349151 9 22767236 [A/G] NR_038977 LINC01239 Silent rs1375292 9 22767738 [T/C] NR_038977 LINC01239 Silent rs643958 9 22768289 [T/C] NR_038977 LINC01239 Silent rs10965447 9 22768666 [A/G] NR_038977 LINC01239 Silent rs10115398 9 22770044 [A/G] NR_038977 LINC01239 Silent rs10811771 9 22770886 [A/G] NR_038977 LINC01239 Silent rs593899 9 22774651 [T/C] NR_038977 LINC01239 Silent rs6475682 9 22776141 [T/C] NR_038977 LINC01239 Silent rs1098977 9 22780930 [T/C] NR_038977 LINC01239 Silent rs547279 9 22781709 [T/C] NR_038977 LINC01239 Silent rs501290 9 22784110 [A/C] NR_038977 LINC01239 Silent rs486933 9 22786315 [T/G] NR_038977 LINC01239 Silent rs7852316 9 22790288 [A/G] NR_038977 LINC01239 Silent rs10811773 9 22791520 [A/G] NR_038977 LINC01239 Silent rs586554 9 22796540 [T/C] NR_038977 LINC01239 Silent rs7032336 9 22799090 [T/C] NR_038977 LINC01239 Silent rs12555613 9 22799213 [A/G] NR_038977 LINC01239 Silent rs842853 9 22801570 [A/G] NR_038977 LINC01239 Silent rs10125975 9 22805644 [T/C] NR_038977 LINC01239 Silent rs9298841 9 22811336 [A/G] NR_038977 LINC01239 Silent rs7874413 9 22818289 [A/G] NR_038977 LINC01239 Silent rs4571809 9 22819064 [T/G] NR_038977 LINC01239 Silent rs7865016 9 22819407 [T/C] NR_038977 LINC01239 Silent rs6475687 9 22829231 [A/G] rs4369069 9 22834082 [A/G] rs7846858 9 22836549 [A/G] rs4602981 9 22841425 [A/C] rs4446815 9 22847961 [T/C] rs4977797 9 22854439 [T/C] rs10965476 9 22854786 [T/G] rs7857348 9 22856899 [A/G] rs9969855 9 22857606 [A/G] rs7041327 9 22859129 [A/G] rs13297845 9 22862721 [A/G] rs12004142 9 22866134 [T/C] rs4977798 9 22870294 [A/G] rs10965489 9 22876746 [T/C] rs10811794 9 22889619 [T/C] rs2086011 9 22890635 [A/G] rs922364 9 22894794 [A/G] rs10965505 9 22901504 [A/C] rs12336908 9 22903397 [T/C] rs13295272 9 22904005 [T/C] rs1381924 9 22905600 [A/G] rs996367 9 22906349 [A/G] rs10811800 9 22906729 [T/C] rs1381923 9 22909348 [T/G] rs1381922 9 22909498 [T/C] rs1381921 9 22909814 [T/C] rs10965517 9 22911500 [A/G] rs1954543 9 22913604 [A/G] rs1937037 9 22913891 [T/G] rs12343679 9 22915652 [A/G] rs10965520 9 22916961 [A/G] rs1463006 9 22917331 [A/G] rs10757373 9 22917801 [A/G] rs1463033 9 22919588 [T/C] rs2000341 9 22925116 [A/G] rs2383246 9 22934249 [T/C] rs1463019 9 22934328 [A/G] rs1381919 9 22937343 [T/C] rs10965529 9 22943509 [T/G] rs12341716 9 22947192 [T/C] rs10511719 9 22947998 [T/C] rs1599698 9 22956519 [T/C] rs4977810 9 22957359 [A/C] rs10965536 9 22961073 [T/C] rs10733382 9 22964237 [T/G] rs10965542 9 22966185 [T/C] rs10757377 9 22967726 [A/C] rs1463026 9 22969947 [T/C] rs7020651 9 22972837 [A/C] rs7867193 9 22982002 [T/C] rs10811812 9 22985180 [T/G] rs10811813 9 22985856 [T/C] rs10965553 9 22986069 [A/G] rs958562 9 22987003 [T/C] rs10811815 9 22987088 [A/G] rs1350996 9 22987182 [A/G] rs931026 9 22988063 [A/G] rs12238170 9 22989686 [T/C] rs12686385 9 22999426 [A/G] rs1023913 9 23003005 [T/C] rs1463009 9 23012833 [T/C] rs10123865 9 23017610 [T/C] rs1576676 9 23018731 [A/G] rs11999590 9 23023866 [A/G] rs7859974 9 23024202 [T/G] rs4977816 9 23039269 [T/G] rs10965572 9 23042805 [T/C] rs1331597 9 23050746 [A/G] rs7019344 9 23051397 [T/C] rs2383251 9 23055362 [T/C] rs12375567 9 23059458 [T/C] rs10965577 9 23059968 [A/G] rs10965580 9 23060945 [A/C] rs10965583 9 23062503 [T/C] rs12375524 9 23064815 [A/G] rs1416505 9 23073339 [T/C] rs10511716 9 23073969 [A/G] rs1416503 9 23074207 [A/G] rs2225965 9 23074432 [A/G] rs4977596 9 23078402 [A/G] rs10511715 9 23079238 [A/C] rs10811830 9 23081217 [T/C] rs12352937 9 23081882 [A/G] rs10811831 9 23082438 [T/C] rs9792672 9 23087926 [T/C] rs10965603 9 23092415 [A/G] rs1934115 9 23103266 [T/G] rs10511712 9 23117288 [T/G] rs4977824 9 23121911 [T/C] rs1538492 9 23127310 [A/G] rs4977826 9 23127562 [T/C] rs16906847 9 23127572 [A/G] rs10757391 9 23127648 [A/C] rs10757392 9 23128281 [T/C] rs1339171 9 23130500 [A/G] rs10965655 9 23132263 [T/C] rs10811853 9 23132496 [T/C] rs10757394 9 23132614 [A/G] rs10965663 9 23137966 [T/C] rs10811855 9 23138534 [A/G] rs10441708 9 23141807 [A/C] rs7873939 9 23142396 [A/C] rs10811856 9 23142874 [A/G] rs4977602 9 23156922 [T/G] rs4007613 9 23161023 [A/G] rs2789476 9 23161189 [T/C] rs1591842 9 23162207 [A/G] rs7871386 9 23166743 [T/C] rs7869437 9 23171045 [A/G] rs1105391 9 23171860 [A/C] rs1111819 9 23172096 [A/G] rs7033378 9 23176101 [T/C] rs7038289 9 23177606 [A/C] rs1227466 9 23181445 [T/C] rs1227463 9 23182825 [A/G] rs4610838 9 23183078 [A/G] rs1227458 9 23184130 [T/C] rs1227456 9 23184533 [T/C] rs10757399 9 23186453 [T/C] rs10965688 9 23188081 [A/G] rs10811866 9 23191038 [T/C] rs10811867 9 23199445 [T/G] rs1339160 9 23200026 [T/C] rs10811869 9 23200174 [T/C] rs10811872 9 23204090 [A/G] rs10120394 9 23207852 [A/G] rs10965704 9 23216803 [T/C] rs10811875 9 23219697 [A/G] rs1339140 9 23222186 [A/C] rs9298846 9 23226243 [T/C] rs10113990 9 23231298 [T/C] rs1578104 9 23242643 [A/G] rs17769769 9 23245863 [T/C] rs16906978 9 23246287 [T/C] rs1934110 9 23246526 [A/G] rs7871692 9 23254622 [A/G] rs7848673 9 23259295 [T/C] rs7868316 9 23262261 [T/C] rs6475722 9 23262705 [A/G] rs2225964 9 23267111 [T/G] rs7022904 9 23274023 [A/G] rs7864583 9 23277704 [A/G] rs10965749 9 23279847 [A/C] rs7030050 9 23284743 [T/C] rs9298848 9 23285718 [A/G] rs6475727 9 23285981 [T/C] rs10757408 9 23288364 [T/C] rs10757409 9 23289501 [A/G] rs1934107 9 23290141 [A/C] rs7047280 9 23297808 [T/C] rs10757411 9 23301612 [T/C] rs10738660 9 23307283 [A/C] rs1544161 9 23307377 [A/G] rs10965762 9 23313019 [A/C] rs10965764 9 23316148 [T/C] rs10965766 9 23320406 [T/C] rs10811886 9 23322467 [A/G] rs7873743 9 23325027 [T/C] rs10811888 9 23325084 [T/C] rs16907121 9 23341848 [A/G] rs17780168 9 23342211 [T/C] rs1929171 9 23343995 [A/C] rs11794152 9 23345347 [A/G] rs7466754 9 23353893 [T/C] rs7029374 9 23358448 [A/G] rs10965797 9 23359506 [T/C] rs1360380 9 23378488 [T/G] rs1360382 9 23379719 [A/G] rs1330924 9 23384589 [A/G] rs1888540 9 23386537 [T/C] rs1330159 9 23386738 [T/C] rs1330164 9 23387019 [T/C] rs17836155 9 23388570 [A/G] rs10965837 9 23400606 [A/G] rs4409483 9 23402710 [T/C] rs10811922 9 23403315 [A/G] rs4977613 9 23403518 [T/C] rs10811923 9 23404131 [T/C] rs7035046 9 23407386 [A/G] rs1581979 9 23407435 [A/C] rs4617240 9 23408637 [T/C] rs10511722 9 23416920 [A/C] rs10511724 9 23420202 [A/G] rs2210293 9 23422031 [A/G] rs10811927 9 23423892 [A/G] rs7873308 9 23425710 [T/C] rs7023393 9 23427158 [T/C] rs1541106 9 23430020 [T/C] rs1330927 9 23431906 [A/C] rs7030403 9 23437895 [T/C] rs7043141 9 23442387 [T/G] rs10738675 9 23442605 [A/C] rs10115057 9 23463060 [T/C] rs404479 9 23479588 [T/G] rs274929 9 23482841 [T/G] rs274931 9 23484919 [A/G] rs9696502 9 23485158 [T/G] rs274932 9 23486165 [A/G] rs10811933 9 23488018 [A/C] rs12338776 9 23498139 [T/C] rs274915 9 23513235 [A/G] NR_121602 LOC101929563 Silent rs7024090 9 23515334 [T/G] NR_121602 LOC101929563 Silent rs17836259 9 23516235 [A/G] NR_121602 LOC101929563 Silent rs10965890 9 23516288 [T/C] NR_121602 LOC101929563 Silent rs6475745 9 23517331 [A/G] NR_121602 LOC101929563 Silent rs175631 9 23523491 [A/G] NR_121602 LOC101929563 Silent rs156396 9 23529626 [A/C] NR_121602 LOC101929563 Silent rs381813 9 23530791 [A/G] NR_121602 LOC101929563 Silent rs7865248 9 23532809 [T/C] NR_121602 LOC101929563 Silent rs655258 9 23542707 [T/C] NR_121602 LOC101929563 Silent rs274958 9 23545229 [T/C] NR_121602 LOC101929563 Silent rs17780641 9 23546391 [T/C] NR_121602 LOC101929563 Silent rs11789575 9 23557134 [A/G] NR_121602 LOC101929563 Silent rs10511729 9 23557227 [T/G] NR_121602 LOC101929563 Silent rs12378826 9 23560604 [A/G] NR_121602 LOC101929563 Silent rs12552015 9 23569119 [A/C] NR_121602 LOC101929563 Silent rs17698074 9 23569870 [A/G] NR_121602 LOC101929563 Silent rs10116397 9 23570688 [T/C] NR_121602 LOC101929563 Silent rs7852159 9 23575805 [A/G] NR_121602 LOC101929563 Silent rs274946 9 23585350 [T/C] NR_121602 LOC101929563 Silent rs12348953 9 23599604 [A/G] NR_121602 LOC101929563 Silent rs10811936 9 23602407 [A/C] NR_121602 LOC101929563 Silent rs4977617 9 23603120 [T/C] NR_121602 LOC101929563 Silent rs12554747 9 23608349 [T/C] NR_121602 LOC101929563 Silent rs10965969 9 23612260 [A/G] NR_121602 LOC101929563 Silent rs7357751 9 23612594 [T/G] NR_121602 LOC101929563 Silent rs1041350 9 23613593 [T/C] NR_121602 LOC101929563 Silent rs10511731 9 23613815 [T/C] NR_121602 LOC101929563 Silent rs12348945 9 23618008 [T/G] NR_121602 LOC101929563 Silent rs7867438 9 23619623 [T/C] NR_121602 LOC101929563 Silent rs7867905 9 23619821 [A/G] NR_121602 LOC101929563 Silent rs10965977 9 23622640 [T/C] NR_121602 LOC101929563 Silent rs17780889 9 23624143 [T/C] NR_121602 LOC101929563 Silent rs10511734 9 23632441 [T/C] NR_121602 LOC101929563 Silent rs1411241 9 23634624 [T/C] NR_121602 LOC101929563 Silent rs12352157 9 23640361 [T/C] NR_121602 LOC101929563 Silent rs7039622 9 23642085 [A/G] NR_121602 LOC101929563 Silent rs4977871 9 23643682 [A/G] NR_121602 LOC101929563 Silent rs9886753 9 23645189 [T/C] NR_121602 LOC101929563 Silent rs10966007 9 23646551 [A/C] NR_121602 LOC101929563 Silent rs10966009 9 23651429 [A/G] NR_121602 LOC101929563 Silent rs16907478 9 23653899 [A/G] NR_121602 LOC101929563 Silent rs10757442 9 23655747 [A/G] NR_121602 LOC101929563 Silent rs1329035 9 23656678 [T/C] NR_121602 LOC101929563 Silent rs6475751 9 23657690 [T/C] NR_121602 LOC101929563 Silent rs6475752 9 23658011 [T/G] NR_121602 LOC101929563 Silent rs4977875 9 23659183 [A/G] NR_121602 LOC101929563 Silent rs7855153 9 23660419 [T/C] NR_121602 LOC101929563 Silent rs7873735 9 23661974 [T/C] NR_121602 LOC101929563 Silent rs10448166 9 23662907 [T/C] NR_121602 LOC101929563 EXON Silent rs4977622 9 23663533 [T/C] NR_121602 LOC101929563 Silent rs7871964 9 23664696 [T/G] NR_121602 LOC101929563 Silent rs10733391 9 23665940 [T/C] NR_121602 LOC101929563 Silent rs7858686 9 23668205 [T/C] NR_121602 LOC101929563 Silent rs10732211 9 23668266 [T/C] NR_121602 LOC101929563 Silent rs1410844 9 23670123 [A/C] NR_121602 LOC101929563 Silent rs996793 9 23676631 [A/G] rs1036105 9 23677432 [T/C] rs1036107 9 23677964 [A/C] rs17468071 9 23679836 [T/C] rs16907598 9 23680743 [A/C] rs2383268 9 23681361 [A/C] rs10966021 9 23685144 [T/C] rs10738679 9 23685236 [A/C] rs932883 9 23686123 [A/C] rs2116227 9 23687455 [A/G] rs4977884 9 23687696 [T/C] rs2043153 9 23689584 [A/C] rs4977886 9 23689717 [A/C] rs7847710 9 23692251 [A/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10733392 9 23694188 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1410840 9 23702349 [T/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1023704 9 23704310 [T/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10966032 9 23705108 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1329024 9 23706348 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1360226 9 23713284 [A/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3829088 9 23713680 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7847989 9 23718363 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4977887 9 23718520 [T/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1329041 9 23720904 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16907652 9 23723599 [A/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12347232 9 23726069 [A/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs717719 9 23731563 [A/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7861646 9 23732000 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3793577 9 23737627 [A/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3793578 9 23738335 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12236195 9 23751700 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16907695 9 23753106 [A/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1473765 9 23755232 [A/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12057071 9 23759368 [A/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3793582 9 23765046 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 EXON Synonymous_L11L,Silent,Silent,Silent,Silent,Silent,Synonymous_L11L,Silent,Silent,Synonymous_L11L,Silent,Silent,Synonymous_L11L,Silent,Synonymous_L11L,Synonymous_L11L,Synonymous_L11L,Synonymous_L11L,Silent,Silent,Synonymous_L11L,Silent,Synonymous_L11L,Silent,Synonymous_L11L,Silent,Silent rs9298850 9 23765511 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3793583 9 23773013 [A/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12346575 9 23773888 [A/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3793589 9 23782685 [A/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2195731 9 23785967 [A/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs992548 9 23787897 [A/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16907731 9 23788214 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1410846 9 23788680 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1653081 9 23790800 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1728256 9 23790801 [A/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16907769 9 23799111 [A/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16907779 9 23801446 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16907782 9 23802442 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3793595 9 23811127 [A/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3793600 9 23811671 [T/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs702223 9 23813840 [A/C] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4977892 9 23816554 [T/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17551174 9 23817548 [A/G] NM_001351464,NM_001351466,NM_001351477,NM_001351478,NM_001351470,NM_001351472,NM_001351463,NM_001351473,NM_001351476,NM_001351462,NM_001351475,NM_004432,NM_001351465,NM_001351469,NM_001351457,NM_001351456,NM_001351458,NM_001351459,NM_001351468,NM_001351474,NM_001351461,NM_001351471,NM_001351460,NM_001171195,NM_001351455,NM_001171197,NM_001351467 ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7870728 9 23829728 [T/G] NM_001351466,NM_001351462,NM_001351456,NM_001351460 ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent rs12341793 9 23829824 [A/G] NM_001351466,NM_001351462,NM_001351456,NM_001351460 ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent rs17557796 9 23830403 [A/G] NM_001351466,NM_001351462,NM_001351456,NM_001351460 ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent rs7869806 9 23831031 [A/G] NM_001351466,NM_001351462,NM_001351456,NM_001351460 ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent rs4142149 9 23831141 [A/C] NM_001351466,NM_001351462,NM_001351456,NM_001351460 ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent rs10811973 9 23831902 [A/G] NM_001351466,NM_001351462,NM_001351456,NM_001351460 ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent rs10966093 9 23832717 [T/C] NM_001351466,NM_001351462,NM_001351456,NM_001351460 ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent rs783455 9 23832770 [A/G] NM_001351466,NM_001351462,NM_001351456,NM_001351460 ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent rs13286215 9 23837464 [A/G] NM_001351466,NM_001351462,NM_001351456,NM_001351460 ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent rs10966097 9 23840388 [A/C] NM_001351466,NM_001351462,NM_001351456,NM_001351460 ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent rs10811978 9 23842612 [A/G] NM_001351466,NM_001351462,NM_001351456,NM_001351460 ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent rs9650694 9 23844194 [A/C] NM_001351466,NM_001351462,NM_001351456,NM_001351460 ELAVL2,ELAVL2,ELAVL2,ELAVL2 Silent,Silent,Silent,Silent rs10811980 9 23852266 [A/G] rs10811984 9 23859906 [T/C] rs12339691 9 23875755 [A/G] rs7847255 9 23880959 [T/C] rs1376141 9 23887854 [A/G] rs4977897 9 23889347 [A/G] rs1528049 9 23892846 [A/G] rs515951 9 23897432 [T/C] rs542527 9 23898021 [A/G] rs2383296 9 23901927 [T/G] rs896085 9 23912009 [A/C] rs10966141 9 23940420 [A/G] rs13291363 9 23940643 [A/G] rs6475768 9 23953634 [T/C] rs4977903 9 23972006 [A/G] rs1868727 9 23972117 [A/G] rs7858484 9 23978172 [A/G] rs10966159 9 23979505 [A/G] rs1901155 9 23983817 [T/G] rs1450584 9 24002013 [A/G] rs10812016 9 24007751 [A/C] rs10966173 9 24013674 [T/C] rs10125108 9 24020855 [T/G] rs7028321 9 24023816 [A/C] rs16907985 9 24025818 [T/C] rs7866846 9 24029604 [T/G] rs4615671 9 24032281 [T/C] rs4350058 9 24034072 [T/C] rs4645624 9 24034180 [A/G] rs4548269 9 24035011 [A/G] rs10114089 9 24043182 [A/G] rs12340809 9 24047161 [A/G] rs11999150 9 24052569 [T/C] rs7862410 9 24060455 [A/G] rs12683447 9 24063404 [A/C] rs10966191 9 24065751 [T/C] rs7031162 9 24066817 [T/G] rs10812022 9 24072205 [T/C] rs12238237 9 24074100 [T/C] rs12379069 9 24075368 [T/C] rs4977912 9 24091818 [T/C] rs4416909 9 24095294 [T/C] rs10966207 9 24097219 [A/C] rs1333337 9 24102399 [T/C] rs4977917 9 24105508 [A/G] rs2225614 9 24111280 [A/C] rs10966220 9 24113158 [A/G] rs10812027 9 24113936 [T/C] rs12376503 9 24121196 [A/G] rs7848340 9 24125018 [T/C] rs7862252 9 24125062 [A/G] rs12554249 9 24133577 [A/G] rs10966238 9 24133646 [A/G] rs17781302 9 24142314 [A/C] rs10812030 9 24146203 [A/G] rs2298620 9 24146436 [A/G] rs7850169 9 24152518 [A/C] rs17176112 9 24156484 [A/G] rs16923681 9 24156917 [T/C] rs7861290 9 24160321 [A/G] rs7848321 9 24164332 [A/G] rs10124866 9 24175234 [T/C] rs4977646 9 24190635 [A/G] rs7033936 9 24190647 [T/C] rs17771522 9 24192164 [T/G] rs7028478 9 24192964 [T/C] rs7031817 9 24193119 [T/C] rs4977922 9 24201121 [A/C] rs7871735 9 24205004 [T/G] rs17195961 9 24212352 [A/C] rs480502 9 24231246 [T/C] rs718339 9 24233393 [T/C] rs4977927 9 24234492 [T/G] rs10046801 9 24244259 [A/G] rs12336381 9 24244920 [A/G] rs10812040 9 24254082 [A/G] rs17771619 9 24262091 [T/C] rs1410964 9 24272883 [A/G] rs637658 9 24284921 [T/G] rs7031702 9 24290018 [T/C] rs7868331 9 24292583 [A/G] rs6475790 9 24298508 [A/C] rs10966279 9 24317138 [A/G] rs17198062 9 24322545 [T/C] rs12345327 9 24332121 [A/G] rs16908250 9 24335841 [T/C] rs10491801 9 24346050 [A/G] rs12345755 9 24350071 [T/C] rs829750 9 24351770 [T/C] rs16908321 9 24375619 [T/C] rs7039851 9 24399969 [A/C] rs16908354 9 24422937 [A/G] rs2383452 9 24428103 [A/G] rs7871454 9 24428896 [A/G] rs13294480 9 24460541 [T/G] rs4618784 9 24467698 [A/G] rs7852101 9 24471843 [A/C] rs10757476 9 24479050 [T/C] rs10812053 9 24482743 [T/C] rs16908399 9 24488294 [T/C] rs11788362 9 24493958 [T/C] rs10812054 9 24495241 [A/G] rs12002240 9 24498325 [T/C] rs7855944 9 24502737 [A/C] rs12003151 9 24505123 [T/G] rs1411215 9 24515111 [T/C] rs16908429 9 24522869 [T/C] rs2257210 9 24527357 [A/G] rs16908449 9 24530857 [T/C] rs10966331 9 24536825 [T/C] rs7018556 9 24538944 [T/C] rs16908477 9 24540910 [A/G] rs6475797 9 24545513 [A/G] NM_001365008,NM_001271706 IZUMO3,IZUMO3 EXON Synonymous_P45P,Synonymous_P45P rs16908488 9 24547244 [A/G] rs7037337 9 24553608 [T/G] rs2149913 9 24573717 [A/G] rs1759039 9 24587252 [A/G] rs7018906 9 24595311 [T/C] rs1162608 9 24605821 [A/G] rs13284068 9 24611322 [T/G] rs1333490 9 24613381 [T/C] rs10812061 9 24616032 [T/C] rs1162610 9 24625115 [A/G] rs12341864 9 24625154 [A/G] rs1329851 9 24626089 [A/C] rs2772571 9 24631812 [A/C] rs1360563 9 24651946 [A/G] rs7852034 9 24654575 [A/G] rs6475805 9 24658725 [T/C] rs10966380 9 24670982 [T/C] rs10966381 9 24671257 [A/C] rs1332677 9 24671602 [A/C] rs1981037 9 24671671 [T/C] rs10966384 9 24672959 [T/C] rs10122018 9 24677263 [A/C] rs12004244 9 24683161 [T/C] rs10966398 9 24687157 [T/C] rs11792697 9 24689992 [A/G] rs1332678 9 24696280 [A/G] rs10966405 9 24698546 [A/G] rs10966415 9 24708079 [A/G] rs12347223 9 24710280 [A/G] rs10966430 9 24716478 [A/G] rs10812089 9 24721911 [A/C] rs11789683 9 24724747 [A/C] rs7870157 9 24725459 [T/C] rs1412647 9 24727049 [A/G] rs16908770 9 24727103 [A/G] rs10123962 9 24730644 [A/G] rs2056416 9 24731623 [T/C] rs16908797 9 24733492 [T/G] rs914713 9 24737563 [A/C] rs7859091 9 24740388 [T/C] rs7873039 9 24740580 [A/C] rs4977954 9 24741297 [T/G] rs10966438 9 24744456 [T/C] rs10114014 9 24745655 [A/G] rs11998852 9 24745911 [A/C] rs7865352 9 24754015 [T/C] rs10124916 9 24756027 [T/G] rs13295819 9 24756335 [T/C] rs7468674 9 24757755 [A/G] rs4319186 9 24768179 [T/C] rs4284108 9 24770615 [A/G] rs10966450 9 24770659 [T/C] rs12379038 9 24770750 [A/G] rs7847436 9 24771352 [A/G] rs4246858 9 24771431 [T/C] rs10116739 9 24771927 [T/G] rs4145038 9 24775586 [A/G] rs17699672 9 24777099 [A/G] rs4625115 9 24781165 [T/C] rs10123842 9 24781300 [T/C] rs12337557 9 24782317 [A/G] rs9298853 9 24783531 [A/G] rs10812095 9 24785247 [A/G] rs10966460 9 24786605 [A/G] rs10732345 9 24788179 [A/G] rs10732346 9 24788197 [T/C] rs1926677 9 24794512 [A/G] rs12551729 9 24795767 [T/C] rs7025209 9 24797747 [A/G] rs9406815 9 24799884 [A/C] rs11795390 9 24805161 [A/G] rs10966479 9 24805660 [A/G] rs17699890 9 24816304 [T/G] rs17772558 9 24820998 [A/C] rs9408006 9 24821064 [A/G] rs17772576 9 24821079 [T/C] rs7039242 9 24821877 [A/G] rs10115985 9 24823390 [A/G] rs10966490 9 24823420 [A/G] rs2026590 9 24833789 [T/G] rs10122826 9 24836923 [A/G] rs9406825 9 24837092 [A/G] rs7867489 9 24837608 [T/C] rs2038965 9 24838852 [T/C] rs6475823 9 24845142 [T/C] rs973778 9 24848892 [A/C] rs7861757 9 24850287 [A/G] rs7024994 9 24855304 [A/G] rs16908910 9 24864882 [A/G] rs7871116 9 24868290 [T/C] rs7863590 9 24875821 [A/G] rs7875618 9 24878417 [A/G] rs7866172 9 24881879 [A/G] rs7873820 9 24883179 [A/C] rs9408015 9 24883440 [T/G] rs10812114 9 24884969 [A/G] rs6475824 9 24886291 [T/C] rs10118854 9 24895221 [T/C] rs7045754 9 24895412 [A/G] rs7046259 9 24895992 [T/C] rs1926671 9 24898858 [A/G] rs7022130 9 24902466 [A/G] rs12686755 9 24905439 [A/G] rs4316218 9 24906802 [T/C] rs1318995 9 24911674 [T/G] rs7849819 9 24912753 [T/C] rs10966561 9 24916557 [A/G] rs10812137 9 24920900 [A/G] rs2126176 9 24922485 [T/C] rs10966571 9 24924449 [T/C] rs7023908 9 24925470 [A/G] rs10966576 9 24932377 [T/C] rs10812142 9 24942014 [A/G] rs1461333 9 24946349 [A/G] rs7856326 9 24956623 [T/C] rs1381151 9 24957550 [A/G] rs10114899 9 24959557 [A/G] rs7851190 9 24960893 [T/C] rs10738700 9 24973797 [A/G] rs7038176 9 24976322 [A/G] rs1461338 9 24977201 [A/G] rs7021001 9 24979796 [A/G] rs10757505 9 24984658 [A/G] rs10812151 9 24985359 [A/G] rs1461340 9 24985660 [A/G] rs10757506 9 24985964 [A/G] rs10812152 9 24988020 [T/C] rs1461331 9 24996421 [T/G] rs10966629 9 24998099 [A/G] rs10812156 9 24998156 [T/C] rs7854450 9 24998417 [T/C] rs1125516 9 24999327 [T/C] rs10812158 9 25003295 [A/G] rs7857156 9 25004127 [A/G] rs964084 9 25005553 [A/G] rs7046929 9 25008242 [A/G] rs10124126 9 25010710 [T/G] rs12338934 9 25024880 [A/C] rs1563950 9 25027430 [T/C] rs17782547 9 25029042 [A/G] rs13286283 9 25029338 [A/G] rs9298861 9 25035251 [A/G] rs7045381 9 25039803 [T/C] rs2614166 9 25047283 [A/G] rs754636 9 25049507 [T/C] rs1381148 9 25049865 [T/C] rs10812169 9 25068476 [T/C] rs2764738 9 25070448 [T/G] rs10966726 9 25090139 [A/G] rs10812183 9 25093183 [A/G] rs3118242 9 25095279 [T/G] rs7852447 9 25098890 [A/G] rs7467005 9 25100472 [T/C] rs12003680 9 25108905 [A/G] rs12004121 9 25112660 [T/G] rs1925478 9 25117372 [A/G] rs12343490 9 25121123 [A/G] rs1886709 9 25122214 [A/G] rs3126961 9 25127661 [T/C] rs3118272 9 25133468 [T/C] rs3118280 9 25139818 [A/G] rs3126975 9 25142445 [A/G] rs3118292 9 25143480 [A/G] rs3118318 9 25157678 [T/C] rs1952053 9 25163771 [T/C] rs10966772 9 25170008 [A/G] rs7034635 9 25176251 [A/G] rs12337176 9 25178084 [T/C] rs1886716 9 25178540 [T/C] rs7033077 9 25188506 [A/G] rs9406859 9 25193401 [A/G] rs7022191 9 25194951 [T/C] rs7039724 9 25195023 [A/G] rs7871597 9 25196181 [A/G] rs1126130 9 25209347 [A/G] rs1412517 9 25212649 [A/G] rs1332437 9 25218359 [A/C] rs11999262 9 25223189 [A/G] rs9408080 9 25227233 [T/C] rs9408081 9 25227443 [T/G] rs10966805 9 25227846 [A/G] rs10812206 9 25233401 [T/C] rs10966810 9 25233460 [T/C] rs10966811 9 25233484 [A/G] rs7027321 9 25241082 [T/G] rs10738708 9 25241316 [A/C] rs10738710 9 25262246 [T/C] rs1625700 9 25263760 [T/C] rs1758734 9 25263918 [A/G] rs10966827 9 25274932 [A/G] rs10812209 9 25275213 [A/G] rs7857330 9 25275893 [A/G] rs1332438 9 25276559 [T/C] rs10119338 9 25276679 [A/C] rs1758742 9 25279649 [T/G] rs10966831 9 25281072 [A/C] rs1758743 9 25281553 [A/G] rs10966833 9 25281912 [T/C] rs10757517 9 25283201 [T/C] rs12344022 9 25285326 [T/C] rs1799615 9 25287180 [A/C] rs10118157 9 25287440 [A/G] rs13289926 9 25292157 [T/C] rs12554573 9 25294481 [T/C] rs4977974 9 25294701 [T/C] rs10966845 9 25296601 [T/C] rs1668962 9 25298264 [T/C] rs17782830 9 25299770 [A/G] rs1332440 9 25301050 [A/G] rs17176169 9 25303763 [A/C] rs2084743 9 25306889 [A/G] rs1751817 9 25307811 [A/G] rs1668984 9 25308896 [A/G] rs1751813 9 25314595 [T/C] rs1855074 9 25316440 [T/C] rs1327392 9 25322181 [T/C] rs1372875 9 25323165 [T/C] rs1372873 9 25325829 [T/G] rs1372872 9 25325895 [A/G] rs1327385 9 25330810 [A/G] rs1751811 9 25334987 [T/G] rs1668986 9 25336447 [A/G] rs1758726 9 25352201 [T/C] rs980462 9 25353887 [A/G] rs7862611 9 25359869 [T/C] rs967671 9 25363830 [T/C] rs10122848 9 25368388 [T/G] rs3849934 9 25377010 [A/G] rs16909339 9 25378030 [A/G] rs10081789 9 25382232 [T/G] rs1576033 9 25384487 [T/G] rs10757521 9 25385317 [T/C] rs1576031 9 25389512 [T/C] rs10121903 9 25390183 [A/G] rs17701704 9 25396789 [A/G] rs945811 9 25398069 [A/G] rs2031735 9 25412587 [T/C] rs1831078 9 25416556 [T/G] rs1576038 9 25416962 [T/C] rs1831077 9 25426760 [A/C] rs4977977 9 25427205 [A/G] rs13287690 9 25432727 [T/G] rs13289164 9 25436091 [T/G] rs12380757 9 25440150 [A/G] rs7035858 9 25440872 [T/C] rs10966910 9 25442538 [T/C] rs12001757 9 25449612 [T/G] rs7856650 9 25451196 [T/C] rs7861656 9 25452963 [A/G] rs10966921 9 25457130 [A/G] rs10812251 9 25461099 [A/C] rs10812252 9 25462188 [T/C] rs1576026 9 25463339 [T/C] rs10966922 9 25465749 [T/C] rs7028841 9 25472081 [T/C] rs6475844 9 25477492 [A/G] rs2225105 9 25480909 [T/C] rs7857140 9 25481661 [T/C] rs10966932 9 25485676 [T/C] rs7024522 9 25487360 [A/G] rs10757544 9 25491653 [T/C] rs10966934 9 25496361 [T/C] rs1591029 9 25498831 [T/C] rs1360523 9 25499528 [T/G] rs10966937 9 25500174 [T/C] rs1332173 9 25500238 [A/G] rs1576786 9 25502753 [A/G] rs1332175 9 25503034 [A/G] rs16909495 9 25503991 [T/C] rs4275297 9 25509545 [T/C] rs1576789 9 25512096 [A/G] rs10812261 9 25512140 [A/G] rs6475847 9 25512506 [A/G] rs2383542 9 25514397 [A/C] rs6475848 9 25517233 [T/G] rs10966943 9 25522087 [T/C] rs17774840 9 25523107 [A/G] rs10966946 9 25527600 [A/C] rs12003047 9 25527621 [T/C] rs10966951 9 25531189 [T/C] rs7861477 9 25531427 [T/C] rs4977676 9 25532512 [T/C] rs1537259 9 25535835 [T/C] rs12004657 9 25539330 [A/C] rs12002354 9 25540603 [A/G] rs944637 9 25544991 [T/G] rs4631560 9 25545690 [T/C] rs12686619 9 25547130 [A/G] rs12238726 9 25547657 [T/G] rs1412378 9 25548004 [T/C] rs17774954 9 25548319 [A/G] rs4977992 9 25548513 [T/C] rs10812270 9 25551426 [T/G] rs7028018 9 25551627 [A/G] rs17783673 9 25552106 [A/G] rs17177122 9 25552267 [A/G] rs1332160 9 25552702 [A/C] rs1412382 9 25554326 [A/C] rs2498725 9 25557615 [A/G] rs1929973 9 25561285 [A/G] rs1412385 9 25562454 [T/G] rs2498738 9 25562784 [A/G] rs2482527 9 25564648 [A/G] rs2498716 9 25564892 [T/C] rs7848711 9 25565442 [T/G] rs2498717 9 25567130 [A/G] rs10757553 9 25576240 [A/C] rs10757554 9 25576545 [A/C] rs12340663 9 25587832 [T/C] rs12684364 9 25594961 [T/C] rs10966975 9 25598014 [T/C] rs4451410 9 25598674 [T/C] rs4246861 9 25599995 [T/C] rs10738725 9 25603439 [T/C] rs10123020 9 25604885 [A/G] rs10966982 9 25606107 [A/C] rs4433235 9 25607913 [T/G] rs10812278 9 25608174 [A/G] rs7032627 9 25610272 [A/G] rs6475857 9 25612202 [T/G] rs10511761 9 25612704 [T/G] rs10966996 9 25616984 [A/G] rs7036377 9 25618052 [A/G] rs7036435 9 25618261 [T/C] rs10967005 9 25627885 [A/G] rs10967006 9 25628210 [A/G] rs4478657 9 25628819 [A/G] rs10812286 9 25629550 [A/G] rs17177480 9 25630951 [A/G] rs10511762 9 25631130 [T/C] rs4531139 9 25636098 [T/C] rs7864401 9 25639747 [T/C] rs4431675 9 25640498 [A/G] rs4512475 9 25643882 [T/G] rs7871606 9 25646816 [T/C] rs7036161 9 25648199 [A/G] rs10967022 9 25648783 [T/C] rs4335219 9 25648883 [T/C] rs4361838 9 25651865 [A/G] rs4534200 9 25652508 [T/C] rs4144933 9 25652937 [T/C] rs7047552 9 25656011 [A/G] rs10117752 9 25658015 [T/C] rs4978003 9 25658076 [A/C] rs12001336 9 25658472 [T/C] rs10967030 9 25659418 [T/C] rs10124907 9 25659637 [A/G] rs4978005 9 25661720 [A/G] rs11999484 9 25667662 [A/G] rs4260970 9 25667695 [A/G] rs12348 9 25677215 [T/C] NM_001004125 TUSC1 EXON Silent rs1128953 9 25677349 [A/C] NM_001004125 TUSC1 EXON Silent rs11999257 9 25679242 [A/G] rs4574937 9 25683220 [A/G] rs13301551 9 25683697 [T/C] rs10967037 9 25689954 [A/G] rs9942969 9 25689989 [A/G] rs4461986 9 25690311 [A/C] rs7031899 9 25691032 [T/C] rs10757564 9 25692824 [A/G] rs4131608 9 25694413 [A/C] rs7033322 9 25695333 [A/C] rs12554383 9 25700484 [T/G] rs1937940 9 25700669 [T/C] rs12005755 9 25713816 [T/C] rs1231330 9 25717386 [A/G] rs12352086 9 25717537 [A/G] rs13286578 9 25719019 [A/G] rs1937955 9 25721500 [A/G] rs7857572 9 25722702 [A/C] rs1231336 9 25727225 [T/C] rs4335220 9 25728739 [T/C] rs10812304 9 25730285 [T/C] rs10117434 9 25733727 [T/C] rs757099 9 25737567 [T/C] rs17039 9 25737868 [A/G] rs1937932 9 25739645 [T/G] rs1231339 9 25740863 [A/C] rs10491876 9 25743020 [A/G] rs1231345 9 25745122 [A/G] rs1231346 9 25745702 [T/G] rs1231353 9 25748799 [A/G] rs1231360 9 25750661 [T/C] rs17290832 9 25751461 [T/C] rs1231362 9 25752310 [A/G] rs1231365 9 25752734 [A/G] rs10967064 9 25753324 [T/G] rs1231373 9 25755422 [T/C] rs1231375 9 25755952 [T/C] rs1634404 9 25772172 [A/G] rs10967072 9 25775262 [A/C] rs1147808 9 25775447 [T/C] rs2522032 9 25783111 [T/C] NR_121604 LINC01241 Silent rs1220090 9 25787040 [T/G] NR_121604 LINC01241 Silent rs1220087 9 25788721 [T/C] NR_121604 LINC01241 Silent rs1220081 9 25792486 [A/C] NR_121604 LINC01241 Silent rs1220078 9 25794090 [A/G] NR_121604 LINC01241 Silent rs1220091 9 25795808 [A/G] NR_121604 LINC01241 Silent rs1235054 9 25800000 [T/C] NR_121604 LINC01241 Silent rs7849755 9 25805162 [A/G] NR_121604 LINC01241 Silent rs1782030 9 25808485 [T/C] NR_121604 LINC01241 Silent rs1220073 9 25812031 [A/G] NR_121604 LINC01241 Silent rs1220071 9 25815074 [T/C] rs989053 9 25815700 [A/G] rs7025024 9 25816219 [A/G] rs10967086 9 25816366 [A/G] rs975346 9 25816707 [T/C] rs1892406 9 25819089 [A/G] rs1220064 9 25825595 [A/G] rs10114570 9 25830482 [T/C] rs1220052 9 25830763 [T/C] rs12337680 9 25831583 [T/C] rs9408099 9 25833408 [A/G] rs10967091 9 25833731 [T/G] rs1220074 9 25837224 [A/C] rs1220044 9 25839353 [A/G] rs16909835 9 25840113 [A/G] rs1843463 9 25845171 [T/C] rs1147813 9 25859709 [T/C] rs10812316 9 25872205 [T/C] rs6475870 9 25878901 [T/C] rs2171099 9 25889362 [T/G] rs993233 9 25890226 [A/G] rs993232 9 25890597 [A/G] rs836954 9 25897335 [T/C] rs16909867 9 25899227 [T/G] rs1219937 9 25901396 [A/G] rs1219936 9 25901711 [A/G] rs1219935 9 25902763 [T/C] rs7864880 9 25909114 [A/G] rs7026829 9 25913301 [T/C] rs1219938 9 25917668 [T/C] rs1219942 9 25919851 [T/C] rs666778 9 25923262 [T/C] rs658858 9 25929148 [A/G] rs541805 9 25934932 [A/G] rs10967133 9 25942793 [A/G] rs10812327 9 25944009 [T/C] rs12348340 9 25950814 [A/G] rs6475872 9 25953815 [T/C] rs1855027 9 25954098 [T/G] rs9886671 9 25955007 [T/C] rs1332339 9 25956931 [T/C] rs10453196 9 25966740 [A/G] rs844356 9 25971497 [T/C] rs473107 9 25973166 [A/C] rs1332348 9 25973292 [A/C] rs475033 9 25979514 [A/G] rs2778457 9 25988943 [T/C] rs671089 9 26003296 [T/C] rs1332340 9 26005487 [T/C] rs12342124 9 26014220 [T/C] rs2383609 9 26014600 [T/C] rs10738742 9 26020806 [T/C] rs9942876 9 26022050 [T/C] rs877755 9 26028352 [T/C] rs12551101 9 26034790 [T/C] rs17494475 9 26035315 [T/C] rs10757585 9 26038217 [A/G] rs10757587 9 26038747 [A/G] rs13293014 9 26044500 [T/C] rs7019491 9 26058260 [A/G] rs10967180 9 26058823 [A/C] rs957252 9 26059028 [A/C] rs10812339 9 26059720 [T/C] rs9406901 9 26062582 [A/G] rs16910121 9 26062842 [A/G] rs12352102 9 26066243 [A/G] rs2383614 9 26068261 [A/C] NM_001004352 LOC100506422 Silent rs946035 9 26069415 [T/C] NM_001004352 LOC100506422 Silent rs4978040 9 26078764 [T/C] NM_001004352 LOC100506422 Silent rs12342356 9 26083996 [A/G] NM_001004352 LOC100506422 Silent rs10812346 9 26086274 [A/G] NM_001004352 LOC100506422 Silent rs10967194 9 26087714 [T/C] NM_001004352 LOC100506422 Silent rs7046442 9 26087907 [A/C] NM_001004352 LOC100506422 Silent rs7854360 9 26100957 [A/G] NM_001004352 LOC100506422 Silent rs10967199 9 26102954 [T/C] NM_001004352 LOC100506422 Silent rs4977692 9 26110570 [A/G] NM_001004352 LOC100506422 Silent rs12350333 9 26110869 [A/G] NM_001004352 LOC100506422 Silent rs6475882 9 26112447 [A/G] NM_001004352 LOC100506422 Silent rs16910176 9 26117767 [T/C] NM_001004352 LOC100506422 EXON Silent rs6475884 9 26121103 [A/C] rs10117168 9 26122149 [A/C] rs7035912 9 26125099 [A/G] rs7030771 9 26127824 [T/C] rs1434863 9 26128568 [A/G] rs10812354 9 26133821 [A/C] rs1434880 9 26134368 [A/C] rs10757596 9 26136235 [A/C] rs2250791 9 26136894 [A/C] rs4978050 9 26149006 [T/C] rs2787165 9 26151961 [T/C] rs2571525 9 26153793 [A/G] rs1434876 9 26155175 [A/C] rs10119966 9 26155894 [T/G] rs985134 9 26156363 [T/C] rs10121215 9 26169347 [A/G] rs10757598 9 26178732 [A/G] rs1434860 9 26179065 [T/C] rs1836463 9 26180249 [A/G] rs10812357 9 26181177 [T/C] rs2571519 9 26184917 [T/C] rs1821553 9 26187635 [A/G] rs10812358 9 26188498 [T/C] rs1933276 9 26189592 [T/C] rs10967221 9 26190234 [A/G] rs10757601 9 26191012 [A/C] rs2787179 9 26192902 [T/C] rs2787180 9 26194166 [T/C] rs10967222 9 26195519 [T/C] rs1369198 9 26195613 [T/C] rs2152969 9 26196672 [A/G] rs2068369 9 26200057 [A/G] rs13293826 9 26201458 [T/G] rs1369212 9 26202481 [T/C] rs10511766 9 26203244 [T/C] rs12684405 9 26205604 [T/C] rs2217796 9 26205694 [A/G] rs1434883 9 26207267 [A/G] rs4977694 9 26208776 [T/C] rs7850733 9 26210141 [A/G] rs10511767 9 26210349 [T/C] rs10967234 9 26210446 [T/G] rs4978054 9 26211820 [A/G] rs10757602 9 26222987 [T/C] rs1369207 9 26225232 [T/C] rs717704 9 26226392 [T/C] rs10967253 9 26233664 [T/C] rs1434857 9 26241359 [T/C] rs10156483 9 26244255 [T/C] rs1932713 9 26248035 [A/G] rs623893 9 26257238 [T/C] rs443014 9 26261340 [A/G] rs432623 9 26269799 [A/G] rs990328 9 26273358 [A/G] rs17784656 9 26273887 [A/G] rs514616 9 26275374 [T/C] rs693087 9 26275493 [T/G] rs1897888 9 26275964 [T/C] rs7470949 9 26276367 [A/G] rs2618024 9 26276392 [T/C] rs7847611 9 26285086 [T/C] rs353436 9 26289217 [T/C] rs2571510 9 26292267 [T/C] rs10967292 9 26294087 [T/C] rs589340 9 26296319 [T/C] rs17776101 9 26297312 [T/C] rs367832 9 26297693 [T/C] rs10511771 9 26298134 [T/C] rs2618032 9 26298970 [A/G] rs17719825 9 26302964 [A/G] rs11793655 9 26307529 [A/G] rs10967301 9 26313753 [A/C] rs2618012 9 26313814 [A/G] rs10967303 9 26316310 [T/C] rs989494 9 26317242 [A/C] rs1336467 9 26317307 [T/C] rs2618014 9 26317973 [A/C] rs2785103 9 26318151 [A/C] rs2785102 9 26318333 [T/C] rs10967307 9 26318387 [A/G] rs7864136 9 26322639 [T/C] rs1414924 9 26324013 [T/C] rs1336461 9 26328954 [T/C] rs2618011 9 26329422 [T/G] rs1336466 9 26333942 [T/C] rs2785113 9 26334802 [A/C] rs10115021 9 26357953 [A/C] rs915508 9 26359485 [T/C] rs2484918 9 26364526 [T/C] rs406058 9 26371680 [A/G] rs958843 9 26376870 [A/C] rs2769970 9 26381874 [T/C] rs400528 9 26382205 [A/G] rs694150 9 26384371 [A/G] rs2618022 9 26391495 [A/C] rs2152634 9 26392058 [A/G] rs1887720 9 26394003 [T/C] rs3896192 9 26397837 [A/G] rs16910426 9 26403617 [T/G] rs367129 9 26409664 [T/C] rs10812392 9 26410031 [T/C] rs1855980 9 26414780 [T/C] rs12005563 9 26419434 [A/G] rs454086 9 26425046 [T/C] rs10967335 9 26433194 [T/C] rs10812394 9 26433751 [A/C] rs7034296 9 26438146 [T/C] rs1571363 9 26440477 [A/G] rs7864971 9 26444583 [A/G] rs10967346 9 26449874 [A/G] rs6475895 9 26453356 [A/G] rs6475897 9 26453723 [A/G] rs1328425 9 26457170 [T/C] rs7044844 9 26458557 [T/C] rs4576502 9 26463378 [A/G] rs2094537 9 26486471 [T/G] rs12554403 9 26489225 [T/C] rs10967370 9 26500046 [T/C] rs1854313 9 26506732 [A/C] rs12339423 9 26507211 [T/C] rs17753877 9 26511000 [T/C] rs7867285 9 26511835 [T/C] rs1359967 9 26515052 [T/C] rs7867988 9 26515617 [A/G] rs4333705 9 26516013 [A/G] rs10967379 9 26516909 [T/C] rs10511789 9 26518883 [A/C] rs12000866 9 26523911 [T/C] rs4111166 9 26524416 [T/C] rs10511788 9 26526249 [T/C] rs12002423 9 26526309 [A/G] rs12004473 9 26526453 [T/C] rs2225078 9 26528575 [T/C] rs10429615 9 26530126 [A/G] rs10967384 9 26530632 [T/C] rs4606151 9 26531228 [T/C] rs10967386 9 26535790 [A/G] rs17692319 9 26538665 [T/C] rs994390 9 26538805 [A/C] rs13294038 9 26546431 [T/C] rs10429492 9 26547991 [T/C] rs6475913 9 26549553 [T/C] rs17754132 9 26551026 [T/C] rs10757612 9 26551726 [A/C] rs6475914 9 26553400 [T/G] rs2383698 9 26555763 [A/C] rs1926757 9 26556311 [T/C] rs1983901 9 26561000 [A/G] rs1328426 9 26565214 [A/C] rs1887221 9 26565913 [A/C] rs1117679 9 26567999 [T/G] rs17754201 9 26569013 [A/G] rs12550891 9 26569055 [T/C] rs7847445 9 26570613 [A/G] rs4977704 9 26571260 [T/C] rs12379692 9 26571285 [A/C] rs2148601 9 26572110 [A/C] rs10118162 9 26572537 [A/G] rs4978082 9 26576086 [A/C] rs964855 9 26576117 [T/C] rs996414 9 26580067 [A/G] rs1926771 9 26582104 [T/C] rs10511787 9 26582312 [A/C] rs10812417 9 26593785 [A/G] rs12379432 9 26595257 [A/G] rs10812418 9 26595380 [T/C] rs12379448 9 26595512 [T/C] rs1926768 9 26596397 [A/G] rs17692544 9 26597540 [T/C] rs4316219 9 26598313 [A/G] rs10812420 9 26600187 [A/C] rs10967431 9 26601230 [A/G] rs913161 9 26603243 [A/C] rs10812423 9 26605757 [T/C] rs1926760 9 26608337 [T/C] rs10812426 9 26609613 [T/C] rs7869769 9 26612557 [T/G] rs10967440 9 26612670 [T/C] rs10812428 9 26614847 [T/C] rs7849701 9 26618389 [A/C] rs10757619 9 26623297 [T/C] rs7868631 9 26624871 [T/G] rs1998909 9 26626081 [A/G] rs10967447 9 26628498 [A/G] rs1926775 9 26629083 [T/C] rs1926773 9 26629382 [A/G] rs913163 9 26631112 [T/C] rs10812432 9 26633841 [A/G] rs7851334 9 26636413 [A/G] rs2164097 9 26637253 [A/C] rs10967453 9 26641557 [T/C] rs1369052 9 26642033 [A/G] rs11794586 9 26643035 [T/C] rs10511783 9 26649956 [T/C] rs989947 9 26650017 [A/G] rs4978089 9 26651364 [A/G] rs10967458 9 26652538 [A/C] rs10812438 9 26653154 [A/C] rs10967459 9 26657127 [A/C] rs10121064 9 26658407 [T/C] rs10967460 9 26658658 [A/G] rs1033991 9 26659562 [T/C] rs10812442 9 26665482 [A/C] rs1434479 9 26668917 [T/C] rs12351975 9 26673735 [T/C] rs980876 9 26674986 [A/G] rs10738754 9 26678360 [T/C] rs10812443 9 26681499 [T/C] rs10812444 9 26684083 [T/C] rs13289242 9 26684890 [T/C] rs12553807 9 26684901 [T/G] rs10812445 9 26685529 [A/G] rs10812447 9 26687936 [T/C] rs13295742 9 26689442 [T/C] rs7871815 9 26694184 [A/G] rs13296414 9 26698331 [A/C] rs12708266 9 26698644 [A/C] rs10967482 9 26699111 [A/G] rs12115390 9 26705815 [T/C] rs10115168 9 26706278 [T/C] rs12376450 9 26707333 [A/C] rs1434482 9 26708668 [T/C] rs1865368 9 26709294 [A/G] rs10757623 9 26713335 [T/G] rs2060409 9 26714614 [T/C] rs10967491 9 26717062 [A/G] rs10117522 9 26719332 [T/C] rs7045601 9 26722736 [A/G] rs10812450 9 26722838 [T/C] rs7868048 9 26728455 [A/G] rs10967496 9 26730057 [A/G] rs1918350 9 26734671 [T/C] rs12347998 9 26735409 [A/G] rs10967503 9 26736051 [A/G] rs10812452 9 26736162 [A/G] rs10967507 9 26742892 [A/G] rs765888 9 26743022 [A/C] rs1434478 9 26749094 [T/C] rs10757627 9 26750142 [T/C] rs9694997 9 26750721 [T/C] rs4978100 9 26751013 [T/C] rs7026561 9 26751543 [T/G] rs7041124 9 26751666 [A/G] rs10283761 9 26755930 [T/C] rs1369050 9 26760477 [A/G] rs1469773 9 26766179 [T/C] rs7853898 9 26767510 [A/G] rs12350711 9 26767842 [T/C] rs12555089 9 26767853 [T/C] rs7046166 9 26770030 [T/C] rs1880947 9 26772805 [T/C] rs2383716 9 26777330 [T/C] rs6475937 9 26783996 [T/C] rs10812464 9 26785338 [T/G] rs12341895 9 26785713 [A/C] rs10511775 9 26788498 [T/C] rs10511774 9 26790633 [A/G] rs10116852 9 26796160 [A/G] rs1336335 9 26796472 [T/G] rs10967540 9 26797676 [A/G] rs12338262 9 26800359 [A/C] rs12339392 9 26804802 [T/C] rs1336336 9 26808023 [T/C] rs10812467 9 26810177 [T/C] rs10812476 9 26834139 [T/G] rs7872881 9 26838839 [T/G] rs10967557 9 26839219 [A/C] rs1336332 9 26843342 [A/G] NM_024828,NM_001167575 CAAP1,CAAP1 Silent,Silent rs10967566 9 26851480 [T/C] NM_024828,NM_001167575 CAAP1,CAAP1 Silent,Silent rs7036871 9 26866642 [T/C] NM_024828,NM_001167575 CAAP1,CAAP1 Silent,Silent rs12350072 9 26867333 [T/C] NM_024828,NM_001167575 CAAP1,CAAP1 Silent,Silent rs7018943 9 26869532 [T/C] NM_024828,NM_001167575 CAAP1,CAAP1 Silent,Silent rs7873073 9 26891902 [T/G] NM_024828,NM_001167575 CAAP1,CAAP1 Silent,Silent rs7038314 9 26893662 [A/G] rs7038218 9 26893731 [T/C] rs7018962 9 26899690 [T/G] rs10114508 9 26902593 [T/C] rs16910873 9 26904699 [T/G] NM_001031689,NM_001321546 PLAA,PLAA EXON Silent,Silent rs12000745 9 26905183 [T/G] NM_001031689,NM_001321546 PLAA,PLAA EXON Silent,Silent rs10812494 9 26911025 [T/C] NM_001031689,NM_001321546 PLAA,PLAA Silent,Silent rs7871286 9 26917718 [T/C] NM_001031689,NM_001321546 PLAA,PLAA Silent,Silent rs10120342 9 26919607 [T/G] NM_001031689,NM_001321546 PLAA,PLAA Silent,Silent rs7042173 9 26922017 [A/C] NM_001031689,NM_001321546 PLAA,PLAA Silent,Silent rs10757635 9 26931255 [A/G] NM_001031689,NM_001321546 PLAA,PLAA Silent,Silent rs12003612 9 26940723 [T/C] NM_001031689,NM_001321546 PLAA,PLAA Silent,Silent rs10511795 9 26953102 [T/C] NM_001099223,NM_001099222 IFT74,IFT74 Silent,Silent rs10812503 9 26960085 [A/G] NM_001099223,NM_001099222,NM_025103,NM_001349928,NM_001099224 IFT74,IFT74,IFT74,IFT74,IFT74 Silent,Silent,Silent,Silent,Silent rs10812505 9 26978170 [A/G] NM_001099223,NM_001099222,NM_025103,NM_001349928,NM_001099224 IFT74,IFT74,IFT74,IFT74,IFT74 EXON Missense_I55M,Missense_I55M,Missense_I55M,Missense_I55M,Missense_I55M rs10967649 9 26993755 [T/G] NM_001099223,NM_001099222,NM_025103,NM_001349928,NM_001099224,NM_022901 IFT74,IFT74,IFT74,IFT74,IFT74,LRRC19 EXON Silent,Silent,Silent,Silent,Silent,Silent rs10812509 9 26993889 [T/C] NM_001099223,NM_001099222,NM_025103,NM_001349928,NM_001099224,NM_022901 IFT74,IFT74,IFT74,IFT74,IFT74,LRRC19 EXON Silent,Silent,Silent,Silent,Silent,Silent rs10967657 9 27006575 [A/G] NM_001099223,NM_001099222,NM_025103,NM_001349928,NM_001099224 IFT74,IFT74,IFT74,IFT74,IFT74 Silent,Silent,Silent,Silent,Silent rs17756299 9 27009738 [A/C] NM_001099223,NM_001099222,NM_025103,NM_001349928,NM_001099224 IFT74,IFT74,IFT74,IFT74,IFT74 Silent,Silent,Silent,Silent,Silent rs7857669 9 27032385 [A/G] NM_001099223,NM_001099222,NM_025103,NM_001349928,NM_001099224 IFT74,IFT74,IFT74,IFT74,IFT74 Silent,Silent,Silent,Silent,Silent rs10812520 9 27047246 [T/C] NM_001099223,NM_001099222,NM_025103,NM_001349928 IFT74,IFT74,IFT74,IFT74 Silent,Silent,Silent,Silent rs16910953 9 27047460 [T/C] NM_001099223,NM_001099222,NM_025103,NM_001349928 IFT74,IFT74,IFT74,IFT74 Silent,Silent,Silent,Silent rs1413824 9 27050593 [A/C] NM_001099223,NM_001099222,NM_025103,NM_001349928 IFT74,IFT74,IFT74,IFT74 Silent,Silent,Silent,Silent rs3429 9 27062721 [T/C] NM_001099223,NM_001099222,NM_025103,NM_001349928 IFT74,IFT74,IFT74,IFT74 EXON Missense_T597I,Missense_T597I,Missense_T597I,Silent rs10967689 9 27066281 [A/G] rs16910976 9 27081879 [A/C] rs10967701 9 27083814 [T/C] rs10812525 9 27084462 [A/G] rs2782434 9 27095072 [T/C] rs1161603 9 27098940 [A/G] rs596427 9 27099244 [A/G] rs10967716 9 27107349 [T/C] rs10967717 9 27108433 [A/G] rs657867 9 27108975 [T/C] rs615375 9 27112311 [T/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs10738763 9 27115768 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs621786 9 27118807 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs666812 9 27120369 [T/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs603085 9 27123260 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs4242698 9 27124745 [A/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs7044842 9 27132514 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs16911047 9 27133016 [A/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs7032817 9 27133385 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs17694796 9 27134636 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs10511799 9 27134868 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs7042119 9 27135831 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs7042267 9 27135962 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs669441 9 27137242 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs12001452 9 27144516 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs12005388 9 27144863 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs4878149 9 27149669 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs7034505 9 27151394 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs7862217 9 27151645 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs7035021 9 27151706 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs4601425 9 27152292 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs664461 9 27152308 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs600728 9 27153866 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs507441 9 27153874 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs1413825 9 27161811 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs506685 9 27163395 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs7036743 9 27164220 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs1107774 9 27164846 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs671804 9 27165030 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs10967750 9 27166159 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs3818283 9 27169124 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs565586 9 27170934 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs7871318 9 27171311 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs10812529 9 27171373 [T/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs3739542 9 27172838 [A/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs3824410 9 27173062 [T/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs666478 9 27173180 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs12554799 9 27173704 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs2208637 9 27176554 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs2224530 9 27176886 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs7047856 9 27179075 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs541615 9 27179530 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs669102 9 27182802 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs10967760 9 27182825 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs16911136 9 27184714 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs17834811 9 27185762 [T/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs581724 9 27187422 [T/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs2152066 9 27188862 [T/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs1334811 9 27190655 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK EXON Missense_V443I,Missense_V339I,Missense_V486I rs481294 9 27190890 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs2224529 9 27192036 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs4879250 9 27193503 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs491892 9 27193541 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs578327 9 27193847 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs3780315 9 27196290 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs10812532 9 27197282 [T/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs7027984 9 27199373 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs4242670 9 27200738 [A/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs692946 9 27201830 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs1413829 9 27201968 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs7876024 9 27202663 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs639225 9 27202870 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK EXON Synonymous_S611S,Synonymous_S507S,Synonymous_S654S rs638203 9 27203134 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs2756900 9 27203625 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs542913 9 27205021 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK EXON Synonymous_R731R,Synonymous_R627R,Synonymous_R774R rs510101 9 27206307 [A/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs641848 9 27208857 [T/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs10757641 9 27212360 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs1111782 9 27212966 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs3737188 9 27213580 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK EXON Synonymous_Y949Y,Synonymous_Y844Y,Synonymous_Y992Y rs3737187 9 27213772 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs534129 9 27214719 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs536078 9 27214972 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs2756901 9 27218053 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs3736819 9 27219058 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs2273719 9 27220066 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK EXON Synonymous_G998G,Synonymous_G893G,Synonymous_G1041G rs2273718 9 27220094 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK EXON Synonymous_L1008L,Synonymous_L903L,Synonymous_L1051L rs7024846 9 27226947 [T/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs2273717 9 27228022 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs10812540 9 27228564 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs1555454 9 27228754 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs2273715 9 27229141 [T/C] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK Silent,Silent,Silent rs857 9 27229786 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK EXON Silent,Silent,Silent rs9987817 9 27230152 [A/G] NM_001290077,NM_001290078,NM_000459 TEK,TEK,TEK EXON Silent,Silent,Silent rs1407300 9 27230196 [T/C] rs1322048 9 27232748 [T/C] rs7858722 9 27233157 [T/C] rs4878368 9 27233367 [A/G] rs7035592 9 27234029 [A/G] rs2057362 9 27247314 [T/C] NR_026679 LINC00032 Silent rs7042745 9 27248177 [A/G] NR_026679 LINC00032 Silent rs10120928 9 27253049 [A/G] NR_026679 LINC00032 Silent rs997675 9 27258216 [A/G] NR_026679 LINC00032 Silent rs17695332 9 27259071 [A/G] NR_026679 LINC00032 Silent rs12348317 9 27260594 [A/G] NR_026679 LINC00032 Silent rs1853186 9 27261030 [A/G] NR_026679 LINC00032 Silent rs744121 9 27261943 [T/C] NR_026679 LINC00032 EXON Silent rs967144 9 27263515 [T/C] NR_026679 LINC00032 Silent rs10812546 9 27264215 [T/C] NR_026679 LINC00032 Silent rs10967828 9 27264539 [T/G] NR_026679 LINC00032 Silent rs12683092 9 27271360 [A/G] NR_026679 LINC00032 Silent rs10967844 9 27274370 [A/G] NR_026679 LINC00032 Silent rs13288748 9 27274428 [A/G] NR_026679 LINC00032 Silent rs10967849 9 27278084 [T/C] NR_026679 LINC00032 Silent rs4878384 9 27280676 [A/G] NR_026679 LINC00032 Silent rs17695487 9 27282942 [T/G] rs10967856 9 27283020 [T/C] rs1126107 9 27284363 [T/C] rs2038571 9 27288113 [T/C] NM_001161585,NM_020641 EQTN,EQTN Silent,Silent rs2383722 9 27288895 [T/G] NM_001161585,NM_020641 EQTN,EQTN Silent,Silent rs10967862 9 27289110 [A/C] NM_001161585,NM_020641 EQTN,EQTN Silent,Silent rs1980661 9 27289812 [T/C] NM_001161585,NM_020641 EQTN,EQTN Silent,Silent rs2383724 9 27290984 [T/C] NM_001161585,NM_020641 EQTN,EQTN Silent,Silent rs3739534 9 27292279 [A/G] NM_001161585,NM_020641 EQTN,EQTN Silent,Silent rs7873922 9 27293009 [T/C] NM_001161585,NM_020641 EQTN,EQTN Silent,Silent rs3824406 9 27296705 [A/G] NM_001161585,NM_020641 EQTN,EQTN EXON Synonymous_D36D,Synonymous_D36D rs7875191 9 27297301 [A/G] rs10967868 9 27297876 [A/G] rs10217315 9 27298500 [A/G] rs17778819 9 27299620 [T/C] rs6475985 9 27301693 [A/G] rs16911369 9 27305461 [A/G] rs6475988 9 27307857 [T/C] rs10967875 9 27309659 [T/C] rs7848125 9 27313439 [T/C] rs10967882 9 27315514 [T/C] rs10217619 9 27316971 [T/C] rs7049080 9 27325452 [T/C] NM_024761 MOB3B EXON Silent rs3410 9 27326060 [A/G] NM_024761 MOB3B EXON Silent rs3409 9 27326088 [A/C] NM_024761 MOB3B EXON Silent rs1555453 9 27326780 [T/G] NM_024761 MOB3B EXON Silent rs2181029 9 27326904 [A/G] NM_024761 MOB3B EXON Silent rs3739531 9 27328964 [T/C] NM_024761 MOB3B EXON Silent rs1984008 9 27329792 [T/C] NM_024761 MOB3B EXON Silent rs3739530 9 27330514 [A/G] NM_024761 MOB3B EXON Silent rs6475989 9 27331324 [T/C] NM_024761 MOB3B Silent rs10967894 9 27332818 [A/G] NM_024761 MOB3B Silent rs1571649 9 27332892 [A/G] NM_024761 MOB3B Silent rs10812569 9 27333155 [T/C] NM_024761 MOB3B Silent rs10738769 9 27334289 [A/G] NM_024761 MOB3B Silent rs10967899 9 27335339 [A/G] NM_024761 MOB3B Silent rs16911416 9 27336207 [A/G] NM_024761 MOB3B Silent rs10967901 9 27338480 [T/C] NM_024761 MOB3B Silent rs10812570 9 27340967 [T/C] NM_024761 MOB3B Silent rs7041639 9 27341338 [A/G] NM_024761 MOB3B Silent rs7852428 9 27344591 [A/G] NM_024761 MOB3B Silent rs7867777 9 27344662 [T/C] NM_024761 MOB3B Silent rs13298013 9 27346374 [A/C] NM_024761 MOB3B Silent rs12005912 9 27349562 [T/C] NM_024761 MOB3B Silent rs12003803 9 27349580 [T/C] NM_024761 MOB3B Silent rs1888380 9 27353460 [A/G] NM_024761 MOB3B Silent rs7044577 9 27354556 [A/C] NM_024761 MOB3B Silent rs10812573 9 27358115 [A/G] NM_024761 MOB3B Silent rs7849799 9 27361872 [A/G] NM_024761 MOB3B Silent rs12349361 9 27361993 [A/G] NM_024761 MOB3B Silent rs7034798 9 27364824 [A/C] NM_024761 MOB3B Silent rs1330921 9 27367278 [A/G] NM_024761 MOB3B Silent rs4483251 9 27371123 [A/G] NM_024761 MOB3B Silent rs1111764 9 27372924 [T/C] NM_024761 MOB3B Silent rs10967916 9 27375843 [A/G] NM_024761 MOB3B Silent rs1330920 9 27378301 [A/G] NM_024761 MOB3B Silent rs12346755 9 27384204 [T/C] NM_024761 MOB3B Silent rs1110155 9 27386505 [T/G] NM_024761 MOB3B Silent rs7021452 9 27389824 [T/C] NM_024761 MOB3B Silent rs11791484 9 27398306 [T/C] NM_024761 MOB3B Silent rs1888382 9 27401297 [A/G] NM_024761 MOB3B Silent rs2150336 9 27402961 [A/G] NM_024761 MOB3B Silent rs11787669 9 27407914 [A/G] NM_024761 MOB3B Silent rs11788670 9 27412769 [A/G] NM_024761 MOB3B Silent rs17696142 9 27428550 [A/G] NM_024761 MOB3B Silent rs1161680 9 27430232 [T/C] NM_024761 MOB3B Silent rs4878454 9 27436033 [A/C] NM_024761 MOB3B Silent rs2589053 9 27441537 [T/C] NM_024761 MOB3B Silent rs2589054 9 27443802 [A/G] NM_024761 MOB3B Silent rs1058326 9 27447089 [A/G] NM_024761 MOB3B Silent rs10967939 9 27447337 [A/G] NM_024761 MOB3B Silent rs1822725 9 27447434 [A/G] NM_024761 MOB3B Silent rs944404 9 27450211 [T/C] NM_024761 MOB3B Silent rs4879507 9 27451482 [T/C] NM_024761 MOB3B Silent rs765709 9 27451960 [A/C] NM_024761 MOB3B Silent rs10812599 9 27453327 [T/C] NM_024761 MOB3B Silent rs10967945 9 27455823 [T/C] NM_024761 MOB3B Silent rs7021930 9 27456928 [A/G] NM_024761 MOB3B Silent rs725804 9 27458939 [A/C] NM_024761 MOB3B Silent rs10757663 9 27467670 [A/G] NM_024761 MOB3B Silent rs10511816 9 27468461 [A/C] NM_024761 MOB3B Silent rs7040436 9 27471387 [T/G] NM_024761 MOB3B Silent rs10967951 9 27473099 [T/C] NM_024761 MOB3B Silent rs10967952 9 27474214 [T/C] NM_024761 MOB3B Silent rs1822723 9 27478052 [T/C] NM_024761 MOB3B Silent rs16911545 9 27483012 [A/G] NM_024761 MOB3B Silent rs895023 9 27483959 [A/G] NM_024761 MOB3B Silent rs17835770 9 27484575 [T/C] NM_024761 MOB3B Silent rs17779457 9 27488092 [T/G] NM_024761 MOB3B Silent rs868857 9 27488906 [A/G] NM_024761 MOB3B Silent rs7033736 9 27489121 [T/C] NM_024761 MOB3B Silent rs868856 9 27489251 [A/G] NM_024761 MOB3B Silent rs7046653 9 27490967 [A/G] NM_024761 MOB3B Silent rs2492813 9 27497792 [T/C] NM_024761 MOB3B Silent rs1977661 9 27502986 [A/C] NM_024761 MOB3B Silent rs2166128 9 27508687 [T/C] NM_024761 MOB3B Silent rs10812605 9 27510360 [T/C] NM_024761 MOB3B Silent rs2484314 9 27511284 [T/G] NM_024761 MOB3B Silent rs774351 9 27516640 [A/C] NM_024761 MOB3B Silent rs11792285 9 27519173 [T/C] NM_024761 MOB3B Silent rs10967971 9 27522870 [T/C] NM_024761 MOB3B Silent rs700782 9 27526047 [T/C] NM_024761,NM_020124 MOB3B,IFNK EXON Silent,Silent rs3739527 9 27526480 [A/C] NM_024761,NM_020124 MOB3B,IFNK EXON Silent,Silent rs903603 9 27529316 [A/G] NM_024761 MOB3B Silent rs13290599 9 27533001 [T/G] rs12115245 9 27533151 [T/C] rs4879541 9 27533452 [T/C] rs2814707 9 27536397 [T/C] rs10812611 9 27542261 [T/C] rs3849942 9 27543281 [T/C] rs10812612 9 27545545 [T/C] rs13691 9 27546890 [A/G] NM_001256054,NM_018325 C9orf72,C9orf72 EXON Silent,Silent rs3739526 9 27547313 [T/G] NM_001256054,NM_018325 C9orf72,C9orf72 EXON Silent,Silent rs2643806 9 27548637 [A/G] NM_001256054,NM_018325 C9orf72,C9orf72 EXON Missense_L393F,Missense_L393F rs10117558 9 27550437 [T/G] NM_001256054,NM_018325 C9orf72,C9orf72 Silent,Silent rs12349820 9 27553876 [T/C] NM_001256054,NM_018325 C9orf72,C9orf72 Silent,Silent rs10122902 9 27556780 [A/G] NM_001256054,NM_018325 C9orf72,C9orf72 EXON Synonymous_S290S,Synonymous_S290S rs1565948 9 27559733 [A/G] NM_001256054,NM_018325 C9orf72,C9orf72 Silent,Silent rs3849944 9 27560594 [T/C] NM_001256054,NM_018325,NM_145005 C9orf72,C9orf72,C9orf72 EXON Silent,Silent,Silent rs12347222 9 27560965 [T/G] NM_001256054,NM_018325,NM_145005 C9orf72,C9orf72,C9orf72 EXON Silent,Silent,Silent rs774359 9 27561049 [T/C] NM_001256054,NM_018325,NM_145005 C9orf72,C9orf72,C9orf72 EXON Silent,Silent,Silent rs17769294 9 27561628 [T/C] NM_001256054,NM_018325,NM_145005 C9orf72,C9orf72,C9orf72 EXON Missense_N207S,Missense_N207S,Missense_N207S rs2453554 9 27561800 [T/C] NM_001256054,NM_018325,NM_145005 C9orf72,C9orf72,C9orf72 Silent,Silent,Silent rs2453555 9 27563868 [A/G] NM_001256054,NM_018325,NM_145005 C9orf72,C9orf72,C9orf72 Silent,Silent,Silent rs10757668 9 27567145 [T/C] NM_001256054,NM_018325,NM_145005 C9orf72,C9orf72,C9orf72 EXON Silent,Silent,Silent rs4879572 9 27570051 [A/G] NM_001256054,NM_018325,NM_145005 C9orf72,C9orf72,C9orf72 Silent,Silent,Silent rs2282241 9 27572255 [A/C] NM_001256054,NM_018325,NM_145005 C9orf72,C9orf72,C9orf72 Silent,Silent,Silent rs1948522 9 27575785 [T/C] rs1982915 9 27579560 [A/G] rs12350076 9 27580674 [A/C] rs2783010 9 27581239 [T/C] rs10967992 9 27581980 [T/G] rs12002175 9 27582128 [T/G] rs7868845 9 27584530 [T/C] rs2453556 9 27586162 [A/G] rs702231 9 27588731 [A/C] rs1082112 9 27591569 [A/C] rs10757671 9 27599202 [A/G] rs2477518 9 27599746 [T/C] rs10968001 9 27600645 [T/C] rs480866 9 27601332 [T/C] rs633583 9 27602921 [A/G] rs615849 9 27606780 [T/C] rs813504 9 27609207 [A/G] rs810174 9 27609514 [A/G] rs17779794 9 27610116 [T/C] rs2889829 9 27610657 [A/G] rs504532 9 27615794 [T/C] rs7041638 9 27619290 [A/C] rs10812622 9 27620642 [A/C] rs10968015 9 27621563 [A/G] rs10968017 9 27627074 [T/G] rs536635 9 27627362 [A/G] rs10968018 9 27627785 [A/G] rs11789024 9 27629693 [T/C] rs4879626 9 27630050 [A/G] rs10968022 9 27630126 [A/G] rs4878512 9 27630418 [A/G] rs12555345 9 27630562 [T/C] rs7847656 9 27644077 [T/C] rs2643801 9 27652540 [T/C] rs536246 9 27653714 [T/C] rs2643800 9 27657713 [T/G] rs10511813 9 27664162 [T/C] rs595432 9 27666190 [T/G] rs3904255 9 27670083 [T/G] rs9695050 9 27671898 [T/C] rs1330204 9 27674224 [T/G] rs10968047 9 27674432 [A/G] rs12235880 9 27674777 [T/C] rs7036816 9 27678194 [A/G] rs4436203 9 27679922 [A/G] rs6476005 9 27683762 [T/G] rs10757678 9 27688488 [A/C] rs7039566 9 27696928 [A/G] rs12342010 9 27697177 [T/C] rs7033375 9 27700428 [T/G] rs13291888 9 27702989 [T/C] rs10968078 9 27703432 [T/C] rs10511809 9 27703855 [T/C] rs944183 9 27704877 [T/C] rs6476012 9 27706404 [A/G] rs1411381 9 27707461 [T/G] rs1411379 9 27707666 [A/G] rs17697408 9 27711260 [T/G] rs12555932 9 27711270 [A/G] rs1360267 9 27715940 [A/G] rs951970 9 27722059 [T/C] rs2026147 9 27723713 [A/G] rs2026146 9 27723858 [T/G] rs10757683 9 27724415 [A/G] rs10732349 9 27725305 [A/G] rs4242689 9 27726731 [T/C] rs4559330 9 27726758 [T/C] rs11998938 9 27727763 [T/G] rs4425847 9 27729356 [A/G] rs1857079 9 27733472 [T/C] rs10968089 9 27745466 [A/C] rs1411373 9 27746785 [A/G] rs1774037 9 27749775 [T/G] rs10968093 9 27753227 [A/G] rs10812662 9 27756019 [A/C] rs7851492 9 27766802 [T/C] rs10511806 9 27777614 [A/G] rs12344477 9 27778743 [T/C] rs10968110 9 27792965 [T/C] rs10968114 9 27800007 [A/C] rs7863376 9 27801225 [A/G] rs10968119 9 27803120 [T/G] rs10968120 9 27804540 [T/C] rs10511805 9 27804697 [T/C] rs10968122 9 27808448 [T/G] rs10812667 9 27819540 [T/C] rs17770626 9 27821606 [A/G] rs12238023 9 27824816 [T/C] rs7851811 9 27824832 [T/C] rs10116939 9 27836272 [T/C] rs11999840 9 27838705 [A/C] rs7035013 9 27839530 [T/G] rs11789249 9 27839795 [A/G] rs12376417 9 27840808 [T/C] rs1342095 9 27840948 [A/G] rs7865479 9 27845760 [T/C] rs11795165 9 27848430 [A/G] rs10812673 9 27850239 [A/G] rs947521 9 27856707 [T/C] rs4581139 9 27860390 [T/C] rs10968155 9 27863830 [A/G] rs1004158 9 27865600 [A/G] rs10968157 9 27866582 [A/C] rs2383733 9 27869510 [A/G] rs4878610 9 27872054 [T/C] rs7865942 9 27872232 [A/G] rs10968164 9 27872621 [T/C] rs6476027 9 27874679 [T/C] rs2795345 9 27875173 [A/G] rs2795344 9 27875247 [A/C] rs2778430 9 27878335 [T/C] rs10481575 9 27880815 [A/G] rs2383741 9 27885011 [A/G] rs7469938 9 27894033 [T/C] rs1316922 9 27894682 [A/G] rs1316921 9 27894751 [T/C] rs1930021 9 27895371 [T/C] rs10491821 9 27895649 [T/C] rs1930023 9 27899045 [T/C] rs10968179 9 27899983 [A/C] rs7861173 9 27904779 [T/G] rs10812687 9 27912332 [A/G] rs7873614 9 27914251 [A/G] rs10968196 9 27924051 [A/G] rs7863803 9 27924555 [A/G] rs7030798 9 27926593 [T/G] rs1930037 9 27926612 [A/G] rs10812695 9 27927133 [T/G] rs10491825 9 27930953 [T/C] rs10968202 9 27931179 [A/G] rs10968205 9 27933183 [T/C] rs7022216 9 27933837 [A/C] rs16912014 9 27934607 [T/C] rs1930042 9 27938780 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 EXON Silent,Silent,Silent,Silent rs9644872 9 27945758 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 EXON Silent,Silent,Silent,Silent rs3739601 9 27948427 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 EXON Silent,Silent,Silent,Silent rs10757699 9 27950863 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12003996 9 27962010 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12338581 9 27962075 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968239 9 27972112 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812712 9 27973766 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968242 9 27974507 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12338322 9 27974577 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968243 9 27974789 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968246 9 27977762 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4142124 9 27979665 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7018499 9 27980241 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1930003 9 27980402 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968258 9 27992290 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1930014 9 27997217 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1197944 9 28001944 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7037139 9 28002083 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1197920 9 28002851 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812720 9 28004967 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7028286 9 28007069 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968272 9 28007239 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4880001 9 28011383 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968281 9 28013298 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16912255 9 28015851 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1343453 9 28020746 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1197913 9 28022473 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1197918 9 28023564 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968288 9 28024155 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs869994 9 28024647 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs869995 9 28024654 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2778426 9 28027280 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12684725 9 28028549 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812728 9 28031714 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968293 9 28034028 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1343457 9 28035209 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968295 9 28035596 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7875743 9 28036634 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1930018 9 28036991 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs944646 9 28037082 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1147815 9 28037375 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16912333 9 28037486 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1452352 9 28037611 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1452353 9 28040937 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1198002 9 28041638 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16912396 9 28043199 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1198006 9 28043247 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1198009 9 28044739 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12115635 9 28045814 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968302 9 28045852 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs17511658 9 28045924 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1198010 9 28046213 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1343456 9 28049518 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1147819 9 28050596 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1147820 9 28050777 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812732 9 28053556 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs6476034 9 28053878 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968311 9 28054492 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968314 9 28055616 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12553579 9 28055877 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1901565 9 28055900 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1901566 9 28056067 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968316 9 28056106 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2167643 9 28058180 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2123204 9 28058435 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812736 9 28064690 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2123205 9 28064791 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7853840 9 28068081 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7858580 9 28069562 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7042653 9 28070283 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968329 9 28072851 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7857347 9 28074530 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7033571 9 28075173 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7849984 9 28076254 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16912472 9 28082935 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1839967 9 28083672 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs896585 9 28086281 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2167644 9 28086344 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968337 9 28086683 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4305993 9 28088526 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7847672 9 28093874 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968347 9 28104987 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812741 9 28106898 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs17771324 9 28111873 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7034231 9 28119512 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs17698657 9 28119660 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1452333 9 28120384 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1452335 9 28123402 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1452338 9 28127342 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12349818 9 28129536 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs6476037 9 28129815 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1343452 9 28136460 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12552434 9 28140215 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs17698804 9 28140436 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4573372 9 28141923 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12684801 9 28143059 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2198292 9 28145962 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812745 9 28152658 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812748 9 28158881 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2044961 9 28164645 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2044962 9 28173138 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1452348 9 28176868 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1319535 9 28181085 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs6476041 9 28185536 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7040482 9 28186091 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7045929 9 28187972 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4878817 9 28188444 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16912561 9 28194546 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968379 9 28195206 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968384 9 28198828 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs17771757 9 28199845 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812754 9 28202675 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10511824 9 28205162 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968386 9 28205326 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12682967 9 28207637 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1562972 9 28208463 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7861219 9 28209655 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968388 9 28210699 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4604546 9 28215694 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs13296178 9 28215883 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968391 9 28216153 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4574938 9 28218512 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10511827 9 28221514 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10511825 9 28222606 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4399024 9 28222934 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7357773 9 28227167 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7865194 9 28231047 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7857732 9 28236666 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968404 9 28237928 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10757722 9 28248076 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7044982 9 28250940 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4130944 9 28251169 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs13440274 9 28251718 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7038123 9 28252086 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4279684 9 28254742 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4554572 9 28256245 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4559331 9 28257148 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12057041 9 28257665 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7871342 9 28257737 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812768 9 28263705 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10733429 9 28269335 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs13298436 9 28272794 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968427 9 28273920 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs13301122 9 28276698 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7871547 9 28280654 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs13286682 9 28286225 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812774 9 28294231 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4266734 9 28296644 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968463 9 28297807 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968467 9 28298064 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7855717 9 28299438 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812775 9 28301145 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7027752 9 28301355 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1953003 9 28305521 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs13299028 9 28309788 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs6476055 9 28313126 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2383771 9 28316539 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs3849954 9 28318817 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7860817 9 28321635 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs6476056 9 28327563 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1332286 9 28328038 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1999423 9 28329088 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16912709 9 28333478 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7847504 9 28334137 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs13291498 9 28336185 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs13298550 9 28337698 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs9792406 9 28338911 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10491897 9 28339748 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1360507 9 28340158 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968521 9 28340971 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968522 9 28341892 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12347591 9 28342014 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1331885 9 28342179 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10491895 9 28355201 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7032657 9 28358436 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12551713 9 28358520 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16912725 9 28359782 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs3842979 9 28359979 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs3843937 9 28360213 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs3849956 9 28360711 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16912739 9 28364240 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4879240 9 28365308 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4278232 9 28366398 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7856324 9 28366643 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1331891 9 28367812 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs6476060 9 28368404 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16912763 9 28370761 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12684059 9 28371227 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2383769 9 28372519 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10491894 9 28376487 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1412423 9 28377370 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10757736 9 28378229 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7028019 9 28380167 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1571846 9 28381681 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1331879 9 28381857 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs944594 9 28382153 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1331880 9 28382826 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2150862 9 28383008 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1412226 9 28385612 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7865192 9 28386208 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812795 9 28390177 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968554 9 28391010 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968555 9 28391518 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7019284 9 28394358 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812802 9 28395585 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968556 9 28395773 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7028515 9 28396747 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16912848 9 28398051 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1331903 9 28398636 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4878360 9 28398726 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2183828 9 28399683 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2183829 9 28399778 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1009216 9 28400166 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1002406 9 28400172 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812804 9 28400551 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1929807 9 28402387 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10125103 9 28402960 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7020846 9 28403443 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs6476065 9 28403813 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1331909 9 28407379 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1331910 9 28407568 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7858089 9 28409300 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16912913 9 28410650 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968572 9 28410944 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2183825 9 28412375 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2150855 9 28412544 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968574 9 28413315 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968576 9 28414339 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968577 9 28415512 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10757740 9 28415970 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7849276 9 28417572 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2183826 9 28419193 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7041128 9 28420020 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs874183 9 28426078 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7855030 9 28427576 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs11999408 9 28427729 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812826 9 28437141 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7021018 9 28440394 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10491888 9 28442343 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1331919 9 28445047 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812831 9 28450213 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968607 9 28458823 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7044907 9 28463701 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1888814 9 28470551 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1981007 9 28475532 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10757744 9 28477082 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs979525 9 28480661 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16913186 9 28486163 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7469495 9 28487096 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7874051 9 28490184 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16913201 9 28490459 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7867540 9 28492928 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968622 9 28499876 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968623 9 28500104 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16913251 9 28502193 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7034070 9 28503578 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs6476078 9 28509666 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7857851 9 28509969 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10491886 9 28517001 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16913267 9 28518270 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10757754 9 28520208 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10757755 9 28521811 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12005012 9 28539581 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12003711 9 28542803 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs17832109 9 28550930 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10491884 9 28562149 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10491883 9 28562256 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10118366 9 28563341 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10117773 9 28566849 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812844 9 28568013 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7038354 9 28569575 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1521731 9 28570652 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812846 9 28571014 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7855874 9 28572086 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1115012 9 28577961 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2383772 9 28578198 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2204076 9 28587832 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs2891316 9 28587994 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16913363 9 28595770 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs11998883 9 28599107 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7852443 9 28601794 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7045520 9 28606526 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968668 9 28607069 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968671 9 28609758 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12347952 9 28613702 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10812853 9 28616672 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968679 9 28619450 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968689 9 28626824 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10511828 9 28628500 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs893496 9 28645019 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs6476084 9 28645626 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1155414 9 28647749 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7855149 9 28649685 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968702 9 28649864 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7046685 9 28659143 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12341535 9 28663042 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs11793079 9 28677376 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs12345065 9 28680131 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs16913525 9 28687561 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs10968724 9 28693005 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs723979 9 28697679 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7850649 9 28701333 [A/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs4879261 9 28705607 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1583667 9 28705864 [A/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs7024629 9 28715676 [T/C] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 Silent,Silent,Silent,Silent rs1438478 9 28719213 [T/G] NM_001354575,NM_001354574,NM_152570,NM_001258282 LINGO2,LINGO2,LINGO2,LINGO2 EXON Silent,Silent,Silent,Silent rs16913556 9 28720007 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10968740 9 28722712 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7041270 9 28728183 [A/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs4879262 9 28732830 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs321747 9 28734729 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7851298 9 28736988 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs321757 9 28742352 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs12337454 9 28746938 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10968749 9 28752484 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs16913617 9 28752971 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs321736 9 28753619 [T/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs321738 9 28754535 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs321739 9 28755357 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs321741 9 28756883 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10812871 9 28757900 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10968754 9 28758532 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs188904 9 28758535 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs321746 9 28759983 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs4879265 9 28771619 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs824249 9 28772999 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs824251 9 28773458 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs824252 9 28773602 [A/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10968765 9 28773625 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10491623 9 28775609 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs866630 9 28779376 [A/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10812875 9 28781231 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs824264 9 28782175 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs16913661 9 28783523 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs702237 9 28783632 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs824265 9 28784343 [A/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs824242 9 28787049 [T/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs1389729 9 28793773 [T/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10968773 9 28795700 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs1494337 9 28796648 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs824222 9 28799706 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs16913686 9 28801138 [T/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs824230 9 28804098 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7038242 9 28805269 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs16923882 9 28806129 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs824232 9 28809763 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7852834 9 28812865 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs824236 9 28816121 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs1389728 9 28817957 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs1327362 9 28819784 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs17374075 9 28826452 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs824270 9 28827591 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs824272 9 28828789 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs702246 9 28839438 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs702248 9 28842326 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs13293352 9 28843891 [A/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs1952277 9 28849378 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs16913751 9 28853125 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs866632 9 28855071 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs702252 9 28855630 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs914822 9 28867478 [T/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs320947 9 28869800 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs320955 9 28879500 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7854994 9 28885610 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs4471128 9 28887332 [A/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7046727 9 28895042 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs1368992 9 28895878 [A/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10757769 9 28905235 [A/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs13300441 9 28911017 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs2995889 9 28927193 [T/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs16913934 9 28929089 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs1964389 9 28934898 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7871600 9 28940111 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs13285474 9 28942538 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10491632 9 28942608 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7039434 9 28951731 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs12380760 9 28957553 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs4879290 9 28959079 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs13287598 9 28960723 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7046309 9 28965438 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10968843 9 28970237 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs1434302 9 28975706 [T/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10968854 9 28977705 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10812910 9 28979255 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs4879297 9 28981481 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs928484 9 29003807 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs16914202 9 29013529 [A/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs12683606 9 29015933 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs6476118 9 29017258 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs2210558 9 29018854 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10968884 9 29020053 [A/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs12376696 9 29024733 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7847631 9 29024894 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10968899 9 29032248 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs13287118 9 29034430 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10968907 9 29042229 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10812937 9 29052442 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7468614 9 29054853 [A/T] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs13293280 9 29074499 [A/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs1418344 9 29084708 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs13302466 9 29088460 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs1954280 9 29088547 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10968935 9 29092556 [A/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7019031 9 29112301 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7847094 9 29119535 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs1361708 9 29126329 [A/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs1418358 9 29132164 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10812990 9 29133769 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs1418352 9 29150822 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7870900 9 29153469 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs16914352 9 29154876 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10123671 9 29161218 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs17527268 9 29162369 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10968988 9 29166390 [T/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs17527789 9 29174711 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10757817 9 29192125 [T/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs10491658 9 29198885 [A/C] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs7024949 9 29198980 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs2066346 9 29203366 [A/G] NM_001354575,NM_001354574,NM_001258282 LINGO2,LINGO2,LINGO2 Silent,Silent,Silent rs1928658 9 29214289 [T/C] rs1010587 9 29218907 [T/G] rs10813028 9 29223296 [T/C] rs4879321 9 29226705 [A/C] rs16914502 9 29226761 [A/G] rs10757820 9 29227533 [A/G] rs10757821 9 29230848 [T/G] rs16914523 9 29231781 [A/G] rs10813031 9 29233374 [A/G] rs7864149 9 29234349 [A/G] rs7045302 9 29236498 [T/C] rs2383795 9 29243318 [A/G] rs10491659 9 29244165 [T/G] rs10969027 9 29244767 [T/C] rs1928691 9 29247354 [T/C] rs9298904 9 29248171 [T/C] rs2891324 9 29249698 [A/G] rs10969037 9 29258978 [A/G] rs7852004 9 29261935 [A/G] rs1928676 9 29262510 [T/C] rs10813035 9 29263492 [A/G] rs10119913 9 29264328 [A/C] rs10813039 9 29266639 [A/G] rs7035258 9 29267427 [T/C] rs1928669 9 29269462 [A/C] rs10757826 9 29270224 [A/G] rs7020596 9 29276550 [T/C] rs10116577 9 29281634 [T/C] rs10757831 9 29282192 [T/C] rs7864608 9 29285982 [T/C] rs16914634 9 29291279 [T/C] rs10491661 9 29296753 [T/C] rs10813048 9 29297803 [T/C] rs4879332 9 29299060 [A/C] rs1928663 9 29302701 [A/G] rs10813050 9 29308040 [T/C] rs1928661 9 29309713 [A/G] rs12682678 9 29313166 [T/C] rs10491662 9 29315618 [T/C] rs1169758 9 29317769 [A/G] rs1169757 9 29318382 [T/G] rs12378755 9 29318695 [A/G] rs2183831 9 29323125 [T/C] rs1169753 9 29325150 [A/G] rs1928652 9 29325412 [A/C] rs7023568 9 29326375 [T/G] rs1169751 9 29331710 [A/G] rs10969086 9 29334138 [A/G] rs7040052 9 29335831 [A/G] rs16914695 9 29336303 [A/G] rs4529540 9 29336679 [A/G] rs10969087 9 29337965 [T/C] rs9695393 9 29349856 [A/G] rs10757841 9 29350462 [A/C] rs1004617 9 29350850 [T/C] rs1929831 9 29363582 [A/G] rs10969106 9 29364327 [T/G] rs2150865 9 29364847 [T/C] rs10969108 9 29368665 [T/G] rs4879335 9 29374906 [T/C] rs12686399 9 29393359 [A/C] rs4487868 9 29398399 [T/C] rs10969120 9 29400712 [A/C] rs17533687 9 29402291 [A/G] rs12379537 9 29403851 [A/G] rs16914740 9 29404372 [T/G] rs16914744 9 29404859 [A/C] rs10969132 9 29408135 [T/G] rs13292178 9 29408855 [T/G] rs10969138 9 29409914 [A/G] rs10491665 9 29411568 [A/C] rs10757851 9 29412843 [A/G] rs10813080 9 29419802 [A/C] rs1408512 9 29426093 [T/C] rs2891328 9 29426335 [A/G] rs1575599 9 29431179 [T/C] rs1999426 9 29435030 [T/C] rs13287338 9 29435969 [T/C] rs7043013 9 29436763 [T/C] rs13291586 9 29436823 [A/C] rs7848886 9 29438676 [A/G] rs12379607 9 29440074 [T/G] rs7022573 9 29440562 [T/C] rs7856020 9 29445609 [A/C] rs17535735 9 29445887 [A/G] rs7849929 9 29447139 [T/G] rs7041148 9 29448530 [T/C] rs4879352 9 29457656 [T/C] rs13285271 9 29465624 [A/G] rs12554780 9 29470565 [T/C] rs13295051 9 29472650 [A/G] rs10491670 9 29473498 [A/G] rs10969197 9 29473782 [A/G] rs13440118 9 29476774 [A/G] rs10813104 9 29476855 [T/G] rs7025913 9 29480065 [A/G] rs7040084 9 29483651 [A/G] rs1590444 9 29486705 [A/C] rs10738817 9 29489987 [A/G] rs16914896 9 29500071 [T/C] rs7864125 9 29500531 [A/G] rs12057038 9 29501683 [A/G] rs7026384 9 29508543 [T/C] rs571210 9 29516586 [T/C] rs11536732 9 29516728 [A/C] rs603216 9 29520544 [A/G] rs12380193 9 29533691 [A/C] rs621211 9 29535541 [T/C] rs640850 9 29536618 [A/G] rs681870 9 29539147 [A/G] rs10733440 9 29539183 [T/C] rs1889055 9 29539919 [A/G] rs10738821 9 29540105 [T/C] rs665477 9 29544132 [T/G] rs13290799 9 29545875 [T/C] rs683471 9 29546888 [A/G] rs482067 9 29548583 [T/C] rs10969232 9 29556315 [A/C] rs10813121 9 29556577 [A/G] rs646439 9 29556765 [A/C] rs490511 9 29565060 [T/C] rs10969259 9 29569571 [A/G] rs489383 9 29572017 [A/G] rs488550 9 29572075 [T/C] rs10491680 9 29574928 [T/C] rs483312 9 29575467 [A/G] rs507354 9 29577475 [A/G] rs7856040 9 29584528 [T/C] rs7864533 9 29586738 [T/G] rs12238051 9 29587032 [A/G] rs2184023 9 29588006 [A/G] rs510290 9 29591047 [A/G] rs560764 9 29592836 [T/G] rs558097 9 29593098 [A/G] rs1482071 9 29594380 [A/C] rs503350 9 29594461 [T/C] rs670205 9 29595350 [A/G] rs580215 9 29595826 [T/G] rs1482069 9 29596265 [A/G] rs10757893 9 29599001 [A/G] rs4879368 9 29599326 [A/G] rs12345603 9 29601893 [T/C] rs12352146 9 29606866 [T/G] rs10969287 9 29614435 [A/G] rs10757894 9 29616943 [A/G] rs10969289 9 29618472 [T/C] rs1930395 9 29626137 [T/G] rs7044847 9 29630811 [A/G] rs1889056 9 29631459 [T/C] rs601162 9 29632142 [A/G] rs2128184 9 29636965 [T/C] rs12552131 9 29639093 [A/G] rs12379623 9 29639398 [A/G] rs7847579 9 29640181 [T/G] rs577266 9 29640242 [A/C] rs10813149 9 29647032 [T/C] rs7044773 9 29651607 [T/G] rs7863931 9 29653136 [T/C] rs10969313 9 29659560 [T/C] rs7048366 9 29661276 [A/G] rs10813150 9 29663089 [A/G] rs7047143 9 29664382 [T/C] rs2086573 9 29666098 [A/C] rs10117742 9 29675907 [A/G] rs1114433 9 29678424 [A/G] rs16915158 9 29678786 [T/C] rs10114966 9 29679114 [T/C] rs7030681 9 29685128 [T/G] rs6476148 9 29685572 [T/C] rs12553141 9 29691094 [T/C] rs4574931 9 29699426 [A/G] rs12555325 9 29706139 [A/G] rs2383834 9 29713272 [T/C] rs12375805 9 29715833 [T/C] rs13285631 9 29718934 [T/G] rs7859217 9 29729921 [A/G] rs6476151 9 29730581 [T/C] rs10757901 9 29732140 [A/C] rs12344997 9 29736012 [A/G] rs10757903 9 29737005 [A/G] rs928636 9 29739205 [A/G] rs7849069 9 29739622 [A/G] rs1335172 9 29740463 [T/C] rs1932131 9 29748884 [A/G] rs1932133 9 29750167 [A/C] rs10813161 9 29751705 [T/C] rs4437734 9 29753393 [A/G] rs4471130 9 29753415 [A/G] rs12343946 9 29756657 [T/C] rs972133 9 29758063 [A/C] rs1932134 9 29760044 [A/G] rs1467825 9 29761393 [T/C] rs10969375 9 29783989 [T/C] rs10969376 9 29785304 [T/C] rs10813168 9 29788364 [A/C] rs10738825 9 29788387 [T/C] rs950316 9 29789814 [A/G] rs4879382 9 29791410 [A/C] rs2184513 9 29791863 [A/C] rs10969381 9 29796667 [A/G] rs10969382 9 29800646 [T/C] rs10969385 9 29803895 [A/G] rs1360798 9 29813230 [A/C] rs7022877 9 29815766 [T/C] rs10117882 9 29816084 [A/G] rs1414029 9 29816465 [A/G] rs12352814 9 29823067 [T/C] rs10738827 9 29824057 [T/C] rs16915329 9 29826163 [A/G] rs10969398 9 29830336 [T/C] rs10969399 9 29830721 [T/C] rs1543729 9 29831400 [A/G] rs12345817 9 29833969 [T/G] rs2152210 9 29845253 [A/C] rs7025492 9 29849587 [T/G] rs12347202 9 29861353 [A/G] rs10813187 9 29869252 [T/C] rs4567127 9 29874745 [A/G] rs10813194 9 29881379 [A/G] rs4376570 9 29887284 [T/C] rs12377173 9 29888477 [A/C] rs7871951 9 29894841 [T/G] rs10969441 9 29900225 [A/G] rs6476171 9 29903903 [A/G] rs7048031 9 29904043 [A/C] rs6476173 9 29911013 [A/G] rs9408158 9 29919239 [T/C] rs10448227 9 29921183 [T/C] rs9408160 9 29927537 [A/G] rs12345491 9 29928182 [T/C] rs11999742 9 29931372 [T/C] rs10969455 9 29932578 [A/G] rs2492624 9 29938824 [A/G] rs2502106 9 29938935 [T/C] rs2492626 9 29939556 [T/C] rs4415403 9 29940394 [A/G] rs10813204 9 29942472 [T/C] rs9408166 9 29943307 [A/G] rs10813205 9 29943652 [T/C] rs7020357 9 29950775 [A/G] rs10969475 9 29951544 [T/C] rs10511835 9 29958595 [A/G] rs7029617 9 29961076 [T/C] rs16915458 9 29963072 [A/G] rs7027471 9 29964976 [T/C] rs10813211 9 29976426 [T/C] rs12236822 9 29978410 [A/C] rs17783091 9 29981863 [A/G] rs10969493 9 29983603 [T/C] rs6476179 9 29985815 [T/C] rs9298912 9 29985893 [T/C] rs2813927 9 29986250 [T/C] rs2360192 9 29989597 [A/G] rs10121528 9 29991337 [A/C] rs16915477 9 29991403 [T/C] rs10969497 9 29993527 [A/G] rs7866321 9 29997053 [A/G] rs9408174 9 30002855 [T/C] rs9298914 9 30006830 [T/G] rs1962543 9 30009444 [T/C] rs10511841 9 30019155 [T/C] rs9406958 9 30022860 [A/G] rs2813932 9 30026310 [A/G] rs7032287 9 30030188 [T/C] rs10757934 9 30036300 [A/G] rs10969514 9 30036427 [A/G] rs12375503 9 30038860 [T/C] rs2248860 9 30039545 [A/G] rs12056983 9 30040011 [A/G] rs2804511 9 30043590 [A/G] rs2813941 9 30057012 [A/G] rs13299989 9 30064199 [T/C] rs9406965 9 30064376 [T/C] rs10969535 9 30064499 [A/G] rs10969539 9 30067745 [A/C] rs2360145 9 30068009 [T/G] rs10969547 9 30075086 [A/C] rs2360149 9 30078773 [T/C] rs1984299 9 30080099 [A/G] rs10969554 9 30087981 [A/G] rs1780063 9 30089859 [A/G] rs1633490 9 30094419 [T/C] rs2804505 9 30101419 [T/G] rs2245665 9 30103515 [T/C] rs1780055 9 30106229 [A/G] rs1510909 9 30122786 [T/C] rs11999687 9 30133378 [A/C] rs4878424 9 30138908 [A/G] rs1018254 9 30143230 [T/C] rs7872835 9 30158784 [T/C] rs13290342 9 30175188 [A/C] rs2800343 9 30181745 [T/C] rs7868434 9 30187798 [T/C] rs1419375 9 30194560 [A/G] rs2800328 9 30207721 [T/C] rs1510913 9 30207872 [A/G] rs2769635 9 30212447 [A/G] rs2769643 9 30219494 [T/C] rs1543047 9 30222006 [A/C] rs12349102 9 30235654 [A/G] rs9696659 9 30240159 [T/G] rs12339642 9 30247932 [A/G] rs7021842 9 30253168 [T/C] rs1328165 9 30255328 [A/G] rs10813235 9 30257784 [T/C] rs7867533 9 30257830 [T/G] rs1576160 9 30260156 [T/C] rs1576876 9 30265455 [T/C] rs1360555 9 30272267 [T/C] rs1412626 9 30272455 [A/G] rs12338157 9 30276852 [T/C] rs12336564 9 30280905 [A/G] rs2149165 9 30282776 [A/G] rs10511857 9 30286600 [T/C] rs10124607 9 30297393 [T/C] rs12005673 9 30297661 [T/C] rs10125266 9 30303562 [A/C] rs7024169 9 30308963 [A/G] rs2225172 9 30310098 [T/C] rs9298919 9 30318865 [T/C] rs10969620 9 30323457 [A/G] rs16915873 9 30326044 [T/G] rs3853264 9 30326115 [A/G] rs3853265 9 30329054 [A/G] rs10969638 9 30358123 [T/C] rs12347656 9 30359613 [A/C] rs7029121 9 30360841 [A/G] rs16915923 9 30362055 [A/C] rs10969641 9 30366782 [T/C] rs3904444 9 30375986 [A/G] rs1502888 9 30378901 [A/G] rs10511860 9 30381063 [T/C] rs12553003 9 30398351 [A/G] NR_046204 LINC01242 Silent rs10813243 9 30399295 [T/G] NR_046204 LINC01242 Silent rs6476201 9 30401266 [T/G] NR_046204 LINC01242 Silent rs12338659 9 30403716 [T/G] NR_046204 LINC01242 Silent rs10813246 9 30403952 [A/G] NR_046204 LINC01242 Silent rs3853269 9 30409103 [T/C] rs12351836 9 30413575 [A/G] rs10118094 9 30430337 [T/G] rs12005810 9 30434989 [T/C] rs10969671 9 30438383 [T/C] rs3853275 9 30443903 [A/G] rs1502895 9 30446066 [A/G] rs10757953 9 30447342 [A/G] rs10969681 9 30448896 [A/G] rs3866499 9 30453151 [T/C] rs4879437 9 30458347 [A/G] rs10813259 9 30467137 [A/G] rs10813260 9 30467975 [A/G] rs10738838 9 30468541 [A/G] rs12338721 9 30470839 [A/C] rs7020697 9 30471240 [T/C] rs10813262 9 30484037 [T/G] rs10757958 9 30486331 [T/C] rs4532690 9 30493749 [T/C] rs4878432 9 30500252 [A/G] rs17775810 9 30504349 [T/C] rs10969704 9 30504425 [A/G] rs10813280 9 30521752 [A/C] rs10813281 9 30524250 [T/C] rs12006042 9 30535023 [T/C] rs10117990 9 30555391 [A/C] rs10969757 9 30584575 [T/C] rs1104787 9 30591737 [A/G] rs10757981 9 30598864 [A/G] rs10969777 9 30604262 [A/G] rs12380109 9 30613669 [T/C] rs10969796 9 30619070 [T/C] rs10757983 9 30620840 [A/G] rs10813324 9 30621116 [A/C] rs3849883 9 30639205 [A/G] rs12004245 9 30641824 [T/C] rs12344302 9 30645432 [A/G] rs13302787 9 30645756 [T/G] rs7867594 9 30646764 [T/C] rs10969808 9 30646780 [T/C] rs1033216 9 30647718 [T/G] rs17784643 9 30649713 [A/G] rs7857459 9 30656199 [A/G] rs10125968 9 30666675 [T/G] rs9650700 9 30668911 [A/G] rs10738851 9 30669429 [A/G] rs12337598 9 30677333 [T/C] rs3849892 9 30679704 [T/C] rs7033615 9 30687072 [T/C] rs7872163 9 30695029 [A/G] rs7027645 9 30698142 [T/C] rs10969834 9 30713637 [T/C] rs10511863 9 30728974 [T/C] rs12350524 9 30743422 [A/G] rs13439969 9 30753828 [A/C] rs10969854 9 30753998 [T/C] rs12339715 9 30754785 [A/G] rs16916281 9 30768128 [A/G] rs2791599 9 30770699 [T/G] rs2249529 9 30782465 [T/C] rs1888892 9 30795437 [A/G] rs10969868 9 30797625 [A/G] rs2502921 9 30804872 [A/G] rs10969875 9 30822433 [T/C] rs1115506 9 30825690 [T/C] rs1115507 9 30825999 [A/G] rs10969885 9 30840471 [T/C] rs17776734 9 30864788 [A/C] rs7863381 9 30872374 [T/G] rs12235303 9 30882214 [A/G] rs10969931 9 30883545 [A/G] rs2210441 9 30883856 [T/C] rs10969943 9 30889977 [T/C] rs10969958 9 30903823 [T/C] rs10969963 9 30907219 [A/G] rs10969964 9 30907279 [A/G] rs17785384 9 30907897 [A/G] rs10969969 9 30909009 [T/C] rs1332240 9 30915973 [A/C] rs10813381 9 30918764 [A/G] rs10969976 9 30923793 [A/C] rs952695 9 30925753 [T/C] rs10969982 9 30934859 [T/G] rs16916378 9 30938018 [A/G] rs1332234 9 30953341 [A/G] rs7021156 9 30955393 [A/C] rs7867525 9 30970211 [A/G] rs11790297 9 30974923 [A/G] rs10970001 9 30975578 [A/C] rs2888998 9 30979640 [A/G] rs4626692 9 30981578 [T/C] rs7024400 9 30982465 [T/C] rs7024630 9 30982620 [T/C] rs12001624 9 30983100 [T/C] rs10813392 9 30988320 [T/C] rs10813395 9 30990917 [T/C] rs10156409 9 30995741 [A/G] rs10813399 9 30997203 [T/C] rs10813415 9 31004169 [A/G] rs13290998 9 31018578 [A/G] rs10970058 9 31021219 [T/C] rs2778413 9 31021567 [T/C] rs12343404 9 31021638 [T/G] rs7036584 9 31022187 [A/G] rs10813420 9 31023908 [T/C] rs10757998 9 31024144 [A/G] rs7049218 9 31025113 [A/G] rs2992117 9 31027115 [T/C] rs10757999 9 31027597 [A/G] rs16916442 9 31027880 [A/G] rs17720893 9 31029867 [A/G] rs10970060 9 31030749 [T/C] rs10970061 9 31030836 [A/G] rs17720922 9 31030917 [T/C] rs12338719 9 31037099 [A/G] rs12000796 9 31038399 [A/G] rs13293430 9 31050747 [T/G] rs7862915 9 31055720 [T/C] rs4504716 9 31062352 [T/C] rs10970083 9 31063444 [A/G] rs12552052 9 31064657 [T/C] rs3936927 9 31066983 [T/C] rs1414017 9 31078030 [A/G] rs17777591 9 31078653 [A/C] rs10813447 9 31084302 [A/G] rs13301262 9 31085518 [T/C] rs10738859 9 31085736 [T/G] rs6476259 9 31089681 [T/C] rs13285414 9 31100668 [A/G] rs6476261 9 31101278 [A/G] rs12347592 9 31102874 [A/C] rs16916510 9 31104948 [A/G] rs1360797 9 31105113 [A/G] rs1475793 9 31107451 [T/C] rs10813464 9 31107892 [A/G] rs10970110 9 31108083 [T/C] rs975177 9 31111743 [T/C] rs2184505 9 31116343 [A/G] rs12553076 9 31116823 [A/G] rs2225740 9 31121425 [T/G] rs1335157 9 31123932 [A/G] rs12347937 9 31125355 [T/C] rs11795104 9 31125524 [T/C] rs16916555 9 31136986 [T/G] rs10813477 9 31146393 [T/C] rs1335160 9 31152444 [T/C] rs10758029 9 31163494 [A/C] rs10970179 9 31165480 [T/C] rs10758031 9 31174646 [A/C] rs10970183 9 31178755 [T/C] rs11793357 9 31182134 [T/C] rs4878464 9 31182384 [T/C] rs7862164 9 31189546 [A/G] rs10465068 9 31193338 [T/C] rs12003551 9 31205534 [T/C] rs10738867 9 31209669 [A/G] rs10813516 9 31222420 [A/C] rs13291610 9 31233122 [A/G] rs13292646 9 31233220 [T/C] rs1360665 9 31236422 [A/C] rs2065579 9 31241652 [A/G] rs2050239 9 31242351 [A/C] rs7025164 9 31248679 [T/C] rs12344989 9 31253291 [A/G] rs12337164 9 31254719 [A/G] rs10970246 9 31255726 [T/C] rs10758046 9 31262671 [T/G] rs13293735 9 31263902 [T/C] rs7036237 9 31265278 [A/G] rs1012450 9 31266515 [A/C] rs1158566 9 31269291 [T/G] rs11791890 9 31271770 [A/C] rs12555645 9 31282032 [A/G] rs10465074 9 31287949 [A/G] rs10813525 9 31288508 [A/G] rs10970259 9 31290253 [A/G] rs10970260 9 31291138 [A/C] rs10758050 9 31307968 [T/G] rs3900585 9 31312460 [A/G] rs7020872 9 31314587 [T/C] rs7038347 9 31318420 [A/G] rs10970286 9 31324237 [T/C] rs10813534 9 31325092 [T/C] rs10125602 9 31340536 [T/C] rs6476284 9 31347460 [T/C] rs10813550 9 31351194 [A/G] rs10758055 9 31359237 [T/C] rs1888329 9 31372120 [T/C] NR_135134 LINC01243 EXON Silent rs10121900 9 31376925 [T/G] NR_135134 LINC01243 Silent rs10970317 9 31381021 [A/G] NR_135134 LINC01243 Silent rs7857709 9 31394025 [A/G] rs13296212 9 31394143 [T/C] rs7873690 9 31394275 [T/C] rs1382291 9 31396488 [T/C] rs7857257 9 31397676 [T/C] rs12235995 9 31399459 [A/G] rs7025296 9 31405730 [A/G] rs11793707 9 31408125 [T/C] rs7868129 9 31419228 [T/G] rs7866477 9 31424013 [T/C] rs10758063 9 31439249 [A/G] rs10970340 9 31446429 [A/G] rs10813582 9 31446639 [A/G] rs7856016 9 31446664 [T/C] rs12341631 9 31451670 [T/C] rs10813591 9 31454538 [A/G] rs10970374 9 31470393 [T/C] rs10120052 9 31471679 [A/C] rs10813601 9 31472633 [T/C] rs2447721 9 31473208 [A/G] rs10970378 9 31479215 [A/G] rs1929104 9 31494101 [A/G] rs13297113 9 31500197 [A/C] rs10465076 9 31524219 [T/C] rs16917077 9 31532212 [T/C] rs2502176 9 31533362 [T/C] rs12342878 9 31538491 [T/G] rs6476293 9 31540596 [A/G] rs10511880 9 31540903 [A/G] rs4504728 9 31547550 [T/C] rs7034481 9 31553846 [A/G] rs12337314 9 31555977 [A/G] rs6476296 9 31567404 [T/C] rs16917154 9 31568046 [A/G] rs10970427 9 31573759 [T/C] rs4570254 9 31586876 [T/C] rs4242684 9 31591132 [T/C] rs16917200 9 31602656 [A/G] rs7035270 9 31608609 [A/G] rs1412339 9 31612603 [T/C] rs16924096 9 31614031 [T/C] rs1412341 9 31619571 [T/C] rs11791319 9 31620128 [T/C] rs7851583 9 31628475 [A/C] rs17179862 9 31629459 [A/G] rs781098 9 31629602 [T/C] rs781099 9 31629682 [T/C] rs781101 9 31629777 [A/G] rs17265305 9 31636424 [T/C] rs4879530 9 31636880 [T/C] rs431008 9 31643058 [A/G] rs4879531 9 31645637 [T/C] rs7857381 9 31647645 [A/G] rs895288 9 31656498 [A/G] rs2044401 9 31669518 [A/G] rs10970475 9 31671441 [T/C] rs410684 9 31673588 [T/C] rs10970476 9 31674177 [T/C] rs11790434 9 31682902 [T/C] rs13297624 9 31704278 [T/C] rs12552096 9 31705959 [T/C] rs12552555 9 31713085 [T/C] rs10970502 9 31714812 [T/C] rs288901 9 31729270 [A/G] rs10758078 9 31745109 [T/C] rs1445648 9 31745845 [T/C] rs288884 9 31748036 [A/G] rs10970527 9 31791211 [A/C] rs12347528 9 31799491 [A/C] rs10813645 9 31811400 [A/G] rs1928091 9 31811669 [A/G] rs928031 9 31817321 [T/C] rs780750 9 31819858 [T/C] rs10970532 9 31820755 [A/G] rs7026194 9 31822916 [T/C] rs780757 9 31825468 [A/G] rs780758 9 31825662 [T/C] rs1328740 9 31825872 [T/C] rs10813647 9 31832821 [A/G] rs10738875 9 31836370 [T/C] rs10511886 9 31836555 [T/C] rs10511887 9 31837334 [A/G] rs997609 9 31842496 [T/C] rs16917452 9 31846527 [T/G] rs1576269 9 31849082 [A/C] rs10970559 9 31849851 [T/C] rs7870196 9 31856797 [A/G] rs10813650 9 31868612 [A/G] rs10970568 9 31871335 [T/C] rs10511888 9 31872062 [A/G] rs943927 9 31872624 [T/G] rs6476305 9 31879919 [T/C] rs17191070 9 31892857 [T/C] rs2375725 9 31894436 [T/C] rs7024321 9 31894764 [T/G] rs10970585 9 31895373 [A/G] rs10125694 9 31912519 [T/C] rs10813661 9 31915424 [T/C] rs16917527 9 31924230 [A/C] rs1887874 9 31925048 [A/G] rs4879543 9 31930090 [T/C] rs1602261 9 31938495 [T/C] rs2200964 9 31951536 [T/C] rs13284518 9 31955694 [A/G] rs7025945 9 31970850 [A/G] rs1038268 9 31977623 [A/G] rs2375811 9 31989998 [A/G] rs10813695 9 32002358 [T/C] rs10970672 9 32009054 [A/G] rs10970690 9 32021156 [T/C] rs7024840 9 32035845 [A/C] rs10970699 9 32036357 [A/G] rs6476322 9 32041861 [A/G] rs12685181 9 32057858 [A/G] rs385280 9 32061188 [A/C] rs10813717 9 32068378 [A/G] rs10970734 9 32071372 [A/G] rs1038270 9 32071702 [A/C] rs1508318 9 32078175 [T/C] rs10435795 9 32081117 [T/C] rs7048642 9 32081823 [A/G] rs10758102 9 32081832 [A/G] rs9886775 9 32087232 [T/G] rs10738877 9 32094230 [T/C] rs1508310 9 32104829 [T/C] rs10970780 9 32105254 [A/G] rs6476341 9 32105784 [A/G] rs10813743 9 32110072 [T/C] rs1842636 9 32110777 [A/G] rs16917898 9 32116520 [A/G] rs7849297 9 32117175 [A/G] rs7038301 9 32117710 [T/C] rs12000809 9 32117729 [A/G] rs11790716 9 32119934 [A/C] rs2495643 9 32120093 [T/G] rs10758117 9 32121610 [A/G] rs2174915 9 32122888 [A/C] rs10970789 9 32125244 [A/G] rs2819851 9 32125843 [A/G] rs10970792 9 32127249 [T/C] rs10970796 9 32128828 [T/C] rs2843575 9 32134018 [T/C] rs7859569 9 32137678 [A/G] rs7859572 9 32137688 [A/G] rs2819846 9 32138539 [T/G] rs906585 9 32143671 [T/C] rs10970821 9 32163518 [A/C] rs10758121 9 32165673 [A/G] rs906584 9 32169408 [T/G] rs1567256 9 32169502 [T/C] rs1567255 9 32169647 [A/C] rs1567253 9 32169982 [A/G] rs7854381 9 32171850 [A/G] rs2819842 9 32173751 [A/G] rs16917960 9 32176843 [A/G] rs10970826 9 32176938 [T/C] rs1508332 9 32177577 [T/C] rs1508334 9 32179169 [T/G] rs10970828 9 32181180 [A/G] rs2843582 9 32181573 [T/C] rs1331250 9 32191942 [A/G] rs1929351 9 32192407 [A/C] rs1556395 9 32203380 [T/C] rs1331240 9 32205704 [T/C] rs7853053 9 32211402 [A/G] rs12379725 9 32223204 [A/G] rs13301455 9 32231421 [A/G] rs1331248 9 32234067 [T/C] rs1331249 9 32239114 [A/G] rs10970862 9 32239645 [T/C] rs17285159 9 32243981 [A/G] rs1999368 9 32246791 [A/G] rs10970866 9 32249231 [A/G] rs10970869 9 32255125 [A/G] rs10511898 9 32257426 [T/C] rs10114714 9 32257573 [T/C] rs12346810 9 32258150 [A/G] rs1411872 9 32258600 [T/C] rs10116526 9 32259801 [A/G] rs12336397 9 32262917 [A/G] rs1537156 9 32267867 [A/G] rs7848402 9 32270454 [A/G] rs7849010 9 32270816 [T/C] rs7024902 9 32271795 [A/C] rs7037573 9 32274310 [T/C] rs1547699 9 32275256 [A/G] rs10970892 9 32276752 [T/G] rs3928808 9 32278891 [T/C] rs10970899 9 32282978 [A/C] rs7039600 9 32283644 [T/C] rs1331226 9 32292317 [T/G] rs10511900 9 32295707 [A/G] rs11792665 9 32302837 [T/C] rs1331231 9 32305904 [A/C] rs992710 9 32310726 [A/G] rs1121130 9 32314084 [A/G] rs1411866 9 32316967 [T/C] rs7027564 9 32319302 [T/G] rs12555218 9 32319516 [A/G] rs2094703 9 32319634 [A/G] rs7856471 9 32328019 [T/C] rs7033286 9 32331188 [A/C] rs10970923 9 32331414 [T/C] rs10117454 9 32332855 [T/C] rs11999411 9 32333058 [T/C] rs16918170 9 32333630 [T/C] rs10970932 9 32341611 [A/G] rs4598348 9 32343182 [T/C] rs10970934 9 32344707 [A/C] rs10511903 9 32344825 [T/C] rs10813796 9 32359091 [A/G] rs10970941 9 32361569 [A/G] rs10970945 9 32372280 [A/G] rs7855483 9 32372462 [T/C] rs9792540 9 32374666 [T/C] rs1023087 9 32376618 [T/G] rs10813801 9 32378956 [A/G] rs1023085 9 32381785 [T/C] rs10813803 9 32381910 [T/C] rs7047398 9 32382071 [A/G] rs879450 9 32383600 [T/C] rs867469 9 32383708 [A/G] rs10813805 9 32392611 [A/G] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs1041321 9 32394422 [T/C] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs7847742 9 32395013 [T/C] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs10813808 9 32397920 [T/C] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs7033149 9 32398234 [T/G] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs6476361 9 32401610 [A/G] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs10970961 9 32403290 [T/C] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs4442231 9 32410850 [T/C] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs4879584 9 32412622 [T/C] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs10970969 9 32416386 [T/C] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs2026739 9 32418237 [T/G] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs10970972 9 32424210 [T/C] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs7025336 9 32424645 [T/G] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 EXON Missense_E390D,Missense_E390D,Missense_E390D rs10813814 9 32424893 [A/G] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs13293491 9 32425270 [A/G] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs3780473 9 32425910 [A/G] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 EXON Synonymous_E421E,Synonymous_E421E,Synonymous_E421E rs2375965 9 32427600 [A/G] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs4879586 9 32427874 [A/C] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs13290492 9 32428442 [T/C] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs12555576 9 32431306 [A/G] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs1467712 9 32432681 [T/G] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs10758139 9 32435676 [A/G] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs10813816 9 32437249 [T/C] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs10813818 9 32449244 [T/C] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 Silent,Silent,Silent rs12985 9 32450187 [T/C] NM_001278352,NM_002197,NM_001362840 ACO1,ACO1,ACO1 EXON Silent,Silent,Silent rs7042042 9 32451144 [A/G] rs17288914 9 32452627 [T/C] rs10970986 9 32453278 [T/C] rs7045087 9 32455262 [T/C] rs12006123 9 32456017 [A/G] NM_014314 DDX58 EXON Silent rs12555727 9 32456656 [A/G] NM_014314 DDX58 EXON Silent rs10738889 9 32458053 [A/G] NM_014314 DDX58 Silent rs10738890 9 32458081 [T/C] NM_014314 DDX58 Silent rs3205166 9 32459450 [T/G] NM_014314 DDX58 EXON Synonymous_V800V rs9650702 9 32461331 [A/G] NM_014314 DDX58 Silent rs944582 9 32465770 [A/G] NM_014314 DDX58 Silent rs883948 9 32466278 [A/G] NM_014314 DDX58 Silent rs10813821 9 32467129 [A/G] NM_014314 DDX58 Silent rs4384073 9 32474690 [A/G] NM_014314 DDX58 Silent rs7037171 9 32487010 [T/C] NM_014314 DDX58 Silent rs2274863 9 32487521 [T/C] NM_014314 DDX58 EXON Synonymous_T441T rs12001044 9 32487912 [T/C] NM_014314 DDX58 Silent rs10971001 9 32488421 [A/G] NM_014314 DDX58 Silent rs639949 9 32490675 [T/G] NM_014314 DDX58 Silent rs17289927 9 32492352 [T/C] NM_014314 DDX58 Silent rs10813826 9 32497007 [T/C] NM_014314 DDX58 Silent rs582647 9 32501547 [T/C] NM_014314 DDX58 Silent rs10971005 9 32502413 [T/G] NM_014314 DDX58 Silent rs7026407 9 32502525 [T/G] NM_014314 DDX58 Silent rs669260 9 32503440 [T/C] NM_014314 DDX58 Silent rs621277 9 32516864 [A/G] NM_014314 DDX58 Silent rs10738891 9 32519154 [T/G] NM_014314 DDX58 Silent rs11795343 9 32523737 [T/C] NM_014314 DDX58 Silent rs17290242 9 32524298 [A/G] NM_014314 DDX58 Silent rs626214 9 32532469 [A/C] rs7025666 9 32533829 [T/C] rs657454 9 32534851 [A/G] rs597131 9 32537141 [T/G] rs12348985 9 32539717 [T/C] rs3814518 9 32541535 [A/G] NM_001195622,NM_005802 TOPORS,TOPORS EXON Synonymous_L931L,Synonymous_L996L rs10971019 9 32542204 [A/G] NM_001195622,NM_005802 TOPORS,TOPORS EXON Synonymous_S708S,Synonymous_S773S rs28372759 9 32552683 [T/C] NM_001349118,NM_001349119,NR_146061,NR_146063 SMIM27,SMIM27,SMIM27,SMIM27 Silent,Silent,Silent,Silent rs6476369 9 32555049 [A/C] NR_146061,NR_146063,NM_182739,NM_001199987,NM_002493 SMIM27,SMIM27,NDUFB6,NDUFB6,NDUFB6 Silent,Silent,Silent,Silent,Silent rs10813835 9 32559114 [T/C] NR_146061,NR_146063,NM_182739,NM_001199987,NM_002493 SMIM27,SMIM27,NDUFB6,NDUFB6,NDUFB6 Silent,Silent,Silent,Silent,Silent rs637421 9 32569145 [T/C] NM_182739,NM_001199987,NM_002493 NDUFB6,NDUFB6,NDUFB6 Silent,Silent,Silent rs12000260 9 32586822 [T/G] rs10971038 9 32592503 [A/G] rs688958 9 32592639 [A/G] rs2050455 9 32596952 [A/C] rs540467 9 32601501 [T/C] rs7046331 9 32607492 [A/G] rs2196271 9 32611604 [T/C] rs616239 9 32614523 [T/G] rs10813840 9 32618055 [T/C] rs750970 9 32618885 [A/G] rs10813841 9 32619211 [T/C] rs10813843 9 32625622 [T/C] rs10971047 9 32631369 [T/C] NM_153809 TAF1L EXON Synonymous_T1403T rs10971048 9 32639519 [A/G] rs10971049 9 32642224 [A/C] rs16918411 9 32668703 [T/C] rs10813852 9 32670310 [T/C] rs6476371 9 32671032 [T/C] rs2117523 9 32675417 [T/C] rs4879591 9 32696996 [T/C] rs1329005 9 32698601 [A/G] rs892751 9 32701046 [A/G] rs7846828 9 32701164 [T/C] rs7862812 9 32701552 [T/G] rs7031021 9 32707775 [T/C] rs1328994 9 32717013 [T/C] rs1326917 9 32717956 [A/G] rs1328996 9 32720834 [A/G] rs4879604 9 32721882 [T/C] rs1571126 9 32722172 [T/C] rs12003519 9 32722999 [A/G] rs3849901 9 32723639 [T/C] rs10971100 9 32724225 [A/G] rs10813864 9 32724290 [T/C] rs7021315 9 32724790 [T/G] rs10971105 9 32725612 [A/G] rs7025476 9 32725773 [A/C] rs12337921 9 32735066 [A/G] rs10813868 9 32738005 [T/C] rs10813869 9 32738041 [T/G] rs960083 9 32739599 [T/C] rs1410831 9 32741428 [A/G] rs12551778 9 32748365 [A/G] rs7848558 9 32754309 [A/G] rs7849269 9 32754685 [A/G] rs10758161 9 32755028 [T/C] rs10813873 9 32759228 [T/G] rs11999320 9 32764431 [T/C] rs11788663 9 32765337 [A/G] rs664241 9 32769523 [T/C] rs630276 9 32773035 [T/G] rs17312997 9 32780525 [T/C] rs640747 9 32780898 [T/C] rs10971127 9 32782328 [A/G] rs1810807 9 32784838 [T/C] NM_212558 TMEM215 EXON Synonymous_C219C rs10971128 9 32785076 [T/C] NM_212558 TMEM215 EXON Silent rs644337 9 32785399 [T/C] NM_212558 TMEM215 EXON Silent rs300637 9 32786653 [T/G] NM_212558 TMEM215 EXON Silent rs10813876 9 32788611 [T/C] NM_212558 TMEM215 EXON Silent rs300629 9 32797839 [A/G] rs2439760 9 32802703 [T/C] rs12002929 9 32802996 [T/C] rs10971142 9 32803092 [A/C] rs2767018 9 32810595 [T/C] rs606902 9 32821457 [T/C] rs10971156 9 32824325 [T/C] rs1822234 9 32827302 [T/C] rs10971159 9 32830551 [A/G] rs12552521 9 32831188 [A/G] rs12555111 9 32831281 [A/G] rs596443 9 32834922 [T/G] rs12684467 9 32850506 [A/G] rs10971163 9 32853105 [A/G] rs10971164 9 32854057 [T/C] rs1442286 9 32855756 [T/C] rs7875919 9 32857801 [T/C] rs10813878 9 32859234 [T/C] rs1359719 9 32861992 [T/C] rs4879619 9 32862544 [T/G] rs16918694 9 32865017 [T/C] rs10971169 9 32866253 [T/C] rs10118347 9 32870406 [T/C] rs10758165 9 32870789 [T/G] rs4879621 9 32873495 [A/G] rs1867027 9 32876777 [A/G] rs7865934 9 32876932 [T/C] rs10813887 9 32879341 [A/G] rs10971175 9 32880323 [T/C] rs12683296 9 32883747 [A/G] rs7847699 9 32884738 [A/C] rs10122775 9 32884983 [T/C] rs1888871 9 32886639 [A/G] rs1348255 9 32886717 [T/C] rs10511913 9 32889200 [A/G] rs10118059 9 32889948 [T/C] rs4879635 9 32899807 [A/G] rs1470217 9 32903868 [A/G] rs7042500 9 32907608 [A/G] rs10971207 9 32909543 [T/C] rs10971212 9 32911250 [T/C] rs1442284 9 32912345 [T/C] rs13289434 9 32917428 [A/G] rs4879641 9 32921928 [T/G] rs10465023 9 32923132 [T/C] rs16918866 9 32923482 [T/G] rs12555433 9 32923966 [T/G] rs12552198 9 32925505 [A/G] rs10733465 9 32932194 [T/C] rs10971234 9 32940248 [A/G] rs13294594 9 32948338 [T/C] rs16918917 9 32957444 [T/C] rs4879653 9 32970518 [T/C] rs10971259 9 32978806 [T/C] NM_175069,NM_001195248,NM_001195251,NR_036579,NM_001195250,NM_001195252,NM_001195254,NM_001195249,NR_036578,NR_036576,NR_036577,NM_175073 APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1016674 9 32982687 [T/C] NM_175069,NM_001195248,NM_001195251,NR_036579,NM_001195250,NM_001195252,NM_001195254,NM_001195249,NR_036578,NR_036576,NR_036577,NM_175073 APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3824457 9 32984072 [T/C] NM_175069,NM_001195248,NM_001195251,NR_036579,NM_001195250,NM_001195252,NM_001195254,NM_001195249,NR_036578,NR_036576,NR_036577,NM_175073 APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10813916 9 32990132 [T/C] NM_175069,NM_001195248,NM_001195251,NR_036579,NM_001195250,NM_001195252,NM_001195254,NM_001195249,NR_036578,NR_036576,NR_036577,NM_175073 APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2183870 9 32994500 [T/G] NM_175069,NM_001195248,NM_001195251,NR_036579,NM_001195250,NM_001195252,NM_001195254,NM_001195249,NR_036578,NR_036576,NR_036577,NM_175073 APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX,APTX Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10124051 9 33007411 [T/C] rs10971306 9 33008056 [A/G] rs17226825 9 33010337 [T/C] rs10971335 9 33019435 [T/C] rs10758179 9 33023833 [T/C] rs3818644 9 33025113 [A/C] rs20583 9 33026572 [T/C] NM_001314039,NM_001539 DNAJA1,DNAJA1 EXON Silent,Synonymous_A30A rs2274769 9 33026638 [A/G] NM_001314039,NM_001539 DNAJA1,DNAJA1 Silent,Silent rs10448231 9 33034051 [A/G] NM_001314039,NM_001539 DNAJA1,DNAJA1 Silent,Silent rs1330692 9 33034665 [T/C] NM_001314039,NM_001539 DNAJA1,DNAJA1 Silent,Silent rs16918958 9 33036928 [A/C] NM_001314039,NM_001539 DNAJA1,DNAJA1 Silent,Silent rs10758180 9 33045147 [A/G] NM_018225 SMU1 EXON Silent rs10971368 9 33050343 [T/C] NM_018225 SMU1 Silent rs12379261 9 33058162 [T/C] NM_018225 SMU1 Silent rs10971389 9 33081123 [T/C] rs12552290 9 33082969 [T/C] rs10758185 9 33084384 [T/C] rs10813942 9 33092835 [A/C] rs13300152 9 33097996 [A/G] rs10971406 9 33099668 [T/C] rs544723 9 33103173 [T/G] rs10813946 9 33104524 [A/G] rs1013217 9 33104540 [T/C] rs750592 9 33106619 [A/C] rs16918997 9 33111348 [A/G] NM_001497 B4GALT1 EXON Silent rs16918998 9 33111788 [T/C] NM_001497 B4GALT1 EXON Silent rs16918999 9 33112623 [A/C] NM_001497 B4GALT1 EXON Silent rs10971412 9 33113066 [A/G] NM_001497 B4GALT1 EXON Silent rs7019896 9 33113196 [T/G] NM_001497 B4GALT1 EXON Silent rs7019909 9 33113322 [T/C] NM_001497 B4GALT1 EXON Silent rs2031902 9 33117524 [T/C] NM_001497 B4GALT1 Silent rs3818593 9 33120706 [A/G] NM_001497 B4GALT1 Silent rs12342831 9 33124872 [T/C] NM_001497 B4GALT1 Silent rs4879666 9 33125279 [A/G] NM_001497 B4GALT1 Silent rs10758192 9 33131651 [A/G] NM_001497 B4GALT1 Silent rs3824459 9 33134617 [T/C] NM_001497 B4GALT1 Silent rs1411609 9 33137303 [T/C] NM_001497 B4GALT1 Silent rs10813958 9 33165985 [A/G] NM_001497 B4GALT1 Silent rs7863609 9 33173556 [T/G] NR_108110,NR_108109,NR_108108 B4GALT1-AS1,B4GALT1-AS1,B4GALT1-AS1 Silent,Silent,Silent rs7854765 9 33180228 [A/G] rs10813960 9 33180362 [T/C] rs7038463 9 33186156 [T/C] rs1702956 9 33192940 [A/G] rs1702962 9 33193935 [A/C] rs478689 9 33200956 [A/C] rs545575 9 33203602 [A/G] rs976164 9 33204104 [A/G] rs12351178 9 33205183 [A/G] rs4879670 9 33205408 [T/C] rs4879671 9 33206375 [T/C] rs10758198 9 33210959 [A/G] rs10813965 9 33212335 [A/G] rs1622785 9 33214128 [A/G] rs7855674 9 33215611 [A/G] rs1702639 9 33215662 [T/G] rs1702645 9 33218297 [T/C] rs539826 9 33218668 [T/C] rs830574 9 33228189 [T/C] rs699217 9 33232197 [A/G] rs3866501 9 33232374 [T/C] rs706107 9 33240225 [A/G] NM_014471 SPINK4 EXON Missense_V7I rs480583 9 33245076 [A/G] NM_014471 SPINK4 Silent rs12350735 9 33250767 [A/G] rs16919125 9 33252803 [A/C] NM_004323,NM_001172415,NM_001349286,NM_001349299 BAG1,BAG1,BAG1,BAG1 EXON Silent,Silent,Silent,Silent rs706118 9 33256179 [T/G] NM_004323,NM_001172415,NM_001349286,NM_001349299 BAG1,BAG1,BAG1,BAG1 Silent,Silent,Silent,Silent rs3758271 9 33263208 [T/C] NM_004323,NM_001172415,NM_001349286,NM_001349299 BAG1,BAG1,BAG1,BAG1 Silent,Silent,Silent,Silent rs3758270 9 33263674 [A/G] NM_004323,NM_001172415,NM_001349286,NM_001349299 BAG1,BAG1,BAG1,BAG1 Silent,Silent,Silent,Silent rs831271 9 33270748 [T/G] NM_016410,NM_001195536 CHMP5,CHMP5 Silent,Silent rs7031547 9 33276316 [A/G] NM_016410,NM_001195536 CHMP5,CHMP5 Silent,Silent rs1197969 9 33279542 [T/C] NM_016410,NM_001195536 CHMP5,CHMP5 Silent,Silent rs830576 9 33290532 [A/G] NM_002504,NM_001318758,NM_147134 NFX1,NFX1,NFX1 EXON Silent,Silent,Silent rs706127 9 33303900 [A/G] NM_002504,NM_001318758,NM_147134 NFX1,NFX1,NFX1 Silent,Silent,Silent rs10511908 9 33309913 [T/C] NM_002504,NM_001318758,NM_147134 NFX1,NFX1,NFX1 Silent,Silent,Silent rs2292243 9 33328812 [A/G] NM_002504,NM_001318758,NM_147134 NFX1,NFX1,NFX1 Silent,Silent,Silent rs4879686 9 33343397 [T/G] NM_002504,NM_001318758,NM_147134 NFX1,NFX1,NFX1 Silent,Silent,Silent rs706134 9 33345616 [A/G] NM_002504,NM_001318758,NM_147134 NFX1,NFX1,NFX1 Silent,Silent,Silent rs4878534 9 33354937 [A/G] NM_002504,NM_001318758 NFX1,NFX1 Silent,Silent rs12237401 9 33367088 [T/C] NM_002504,NM_001318758 NFX1,NFX1 Silent,Silent rs2274866 9 33367584 [A/C] NM_002504,NM_001318758 NFX1,NFX1 EXON Missense_P1086Q,Missense_P1087Q rs2230122 9 33369943 [A/G] NM_002504,NM_001318758 NFX1,NFX1 EXON Synonymous_E1110E,Synonymous_E1111E rs4879696 9 33398606 [A/G] NM_001318157,NM_001318158,NM_001318156,NR_134514,NM_001170,NR_134515,NR_134513 AQP7,AQP7,AQP7,AQP7,AQP7,AQP7,AQP7 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3758267 9 33404808 [T/C] rs7029953 9 33406297 [A/G] rs12351969 9 33406907 [A/G] rs10813971 9 33407780 [T/C] rs17337873 9 33408019 [A/G] rs2777738 9 33414173 [T/C] rs3892492 9 33415974 [A/G] rs10758202 9 33420008 [A/G] rs7022937 9 33420062 [A/G] rs7022959 9 33420204 [T/C] rs10813974 9 33420448 [A/G] rs17253315 9 33420467 [T/G] rs4878538 9 33425385 [A/G] rs4878539 9 33427091 [T/C] rs3860985 9 33430585 [A/G] rs3849904 9 33434026 [T/C] rs6476410 9 33434153 [T/C] rs10813979 9 33436612 [A/G] rs34239839 9 33437244 [T/G] rs34146771 9 33439132 [A/G] rs3892777 9 33439148 [A/G] rs12237858 9 33439738 [A/C] rs567691 9 33439829 [T/C] rs10971513 9 33441527 [A/C] NM_004925,NM_001318144 AQP3,AQP3 EXON Silent,Silent rs16919255 9 33441826 [A/C] NM_004925,NM_001318144 AQP3,AQP3 EXON Silent,Silent rs2231235 9 33442272 [A/G] NM_004925,NM_001318144 AQP3,AQP3 Silent,Silent rs2228332 9 33442952 [A/G] NM_004925,NM_001318144 AQP3,AQP3 EXON Synonymous_F130F,Synonymous_F130F rs34942735 9 33443872 [T/C] NM_004925,NM_001318144 AQP3,AQP3 EXON Missense_V43M,Missense_V43M rs34391490 9 33444861 [T/C] NM_004925,NM_001318144 AQP3,AQP3 Silent,Silent rs12555686 9 33447547 [T/G] NM_004925,NM_001318144 AQP3,AQP3 EXON Silent,Silent rs34552278 9 33447553 [A/G] NM_004925,NM_001318144 AQP3,AQP3 EXON Silent,Silent rs17553719 9 33447579 [T/C] NM_004925,NM_001318144 AQP3,AQP3 EXON Silent,Silent rs2777753 9 33451136 [A/C] rs505698 9 33457653 [T/C] rs3860989 9 33460141 [A/C] rs10971520 9 33460846 [T/C] rs12683438 9 33461299 [A/G] rs1060037 9 33461574 [T/C] NM_139235,NM_022917 NOL6,NOL6 EXON Silent,Silent rs2785210 9 33465182 [A/G] NM_139235,NM_022917 NOL6,NOL6 Silent,Silent rs3739680 9 33465928 [T/C] NM_139235,NM_022917 NOL6,NOL6 Silent,Silent rs3739681 9 33466219 [A/C] NM_139235,NM_022917 NOL6,NOL6 EXON Silent,Synonymous_V738V rs2275228 9 33467577 [T/C] NM_139235,NM_022917 NOL6,NOL6 Silent,Silent rs3860990 9 33467595 [T/C] NM_139235,NM_022917 NOL6,NOL6 Silent,Silent rs11795028 9 33468682 [T/C] NM_139235,NM_022917 NOL6,NOL6 Silent,Silent rs2777747 9 33469191 [T/C] NM_139235,NM_022917 NOL6,NOL6 Silent,Silent rs2777746 9 33469406 [T/C] NM_139235,NM_022917 NOL6,NOL6 Silent,Silent rs2777744 9 33473893 [T/G] NM_139235,NM_022917 NOL6,NOL6 EXON Silent,Silent rs7022355 9 33487023 [A/G] rs10758211 9 33518281 [T/C] rs7866888 9 33524775 [A/C] NM_001353432 ANKRD18B Silent rs4120127 9 33525447 [A/G] NM_001353432 ANKRD18B Silent rs10120325 9 33527793 [T/G] NM_001353432 ANKRD18B Silent rs2477414 9 33554121 [T/C] NM_001353432 ANKRD18B Silent rs7853994 9 33572347 [T/C] NM_001353432 ANKRD18B EXON Missense_L1023P rs12378940 9 33573212 [A/G] NM_001353432 ANKRD18B EXON Missense_R1035K rs4556170 9 33576514 [A/G] rs1853722 9 33576579 [T/C] rs10971588 9 33587366 [T/G] rs855471 9 33609013 [T/C] rs10971602 9 33611709 [T/C] rs855495 9 33613660 [T/G] rs855498 9 33613835 [A/G] rs855500 9 33614214 [T/C] rs855508 9 33617310 [T/C] rs855514 9 33618936 [A/G] rs855523 9 33624429 [A/C] NR_003573 ANXA2P2 EXON Silent rs10971607 9 33625360 [T/C] NR_003573 ANXA2P2 EXON Silent rs10814017 9 33629249 [T/C] rs855533 9 33633838 [T/C] rs855534 9 33635164 [T/C] rs12002477 9 33641436 [A/G] rs1101845 9 33643569 [A/G] rs1856202 9 33661286 [A/G] rs1977008 9 33663511 [T/C] rs855465 9 33676027 [A/C] NR_023917 PTENP1 EXON Silent rs855428 9 33694709 [T/C] rs1765372 9 33699373 [T/G] rs855434 9 33700901 [T/C] rs855436 9 33702339 [A/G] rs855441 9 33731480 [A/G] rs10814040 9 33738727 [T/C] rs10758224 9 33739343 [A/G] rs10971679 9 33751865 [A/C] NM_001197097,NM_007343,NM_001197098 PRSS3,PRSS3,PRSS3 Silent,Silent,Silent rs10971687 9 33761112 [T/C] NM_001197097,NM_007343,NM_001197098 PRSS3,PRSS3,PRSS3 Silent,Silent,Silent rs864427 9 33771241 [T/C] NM_001197097,NM_007343,NM_001197098 PRSS3,PRSS3,PRSS3 Silent,Silent,Silent rs1765310 9 33773364 [A/G] NM_001197097,NM_007343,NM_001197098 PRSS3,PRSS3,PRSS3 Silent,Silent,Silent rs706140 9 33784344 [T/C] NM_001197097,NM_007343,NM_001197098 PRSS3,PRSS3,PRSS3 Silent,Silent,Silent rs3925857 9 33785963 [A/G] NM_001197097,NM_007343,NM_001197098 PRSS3,PRSS3,PRSS3 Silent,Silent,Silent rs760098 9 33792265 [A/G] NM_001197097,NM_007343,NM_001197098 PRSS3,PRSS3,PRSS3 Silent,Silent,Silent rs216345 9 33799370 [T/C] rs10971709 9 33804813 [T/C] rs4602979 9 33810791 [A/C] rs216364 9 33818257 [T/C] NM_017811 UBE2R2 Silent rs2486675 9 33845079 [T/G] NM_017811 UBE2R2 Silent rs4515641 9 33846422 [A/G] NM_017811 UBE2R2 Silent rs7037238 9 33849949 [A/G] NM_017811 UBE2R2 Silent rs16934986 9 33852486 [T/C] NM_017811 UBE2R2 Silent rs2050789 9 33880690 [A/G] NM_017811 UBE2R2 Silent rs13302810 9 33888000 [A/C] NM_017811 UBE2R2 Silent rs10081727 9 33888490 [T/G] NM_017811 UBE2R2 Silent rs10971789 9 33915558 [T/C] NM_017811 UBE2R2 Silent rs4817 9 33917498 [T/C] NM_017811 UBE2R2 EXON Silent rs16935278 9 33919176 [A/C] NM_017811 UBE2R2 EXON Silent rs16935280 9 33921176 [T/C] rs11848 9 33921919 [T/C] NM_018449,NM_001282529,NM_001282530 UBAP2,UBAP2,UBAP2 EXON Silent,Silent,Silent rs2277178 9 33921933 [A/G] NM_018449,NM_001282529,NM_001282530 UBAP2,UBAP2,UBAP2 EXON Silent,Silent,Silent rs307690 9 33928426 [T/C] NM_018449,NM_001282529,NM_001282530 UBAP2,UBAP2,UBAP2 Silent,Silent,Silent rs307687 9 33929685 [A/C] NM_018449,NM_001282529,NM_001282530 UBAP2,UBAP2,UBAP2 Silent,Silent,Silent rs307649 9 33932702 [T/G] NM_018449,NM_001282529,NM_001282530 UBAP2,UBAP2,UBAP2 Silent,Silent,Silent rs12377078 9 33934821 [A/C] NM_018449,NM_001282529 UBAP2,UBAP2 Silent,Silent rs307652 9 33935736 [A/G] NM_018449,NM_001282529 UBAP2,UBAP2 Silent,Silent rs307658 9 33941759 [T/C] NM_018449,NM_001282529 UBAP2,UBAP2 EXON Missense_N606S,Missense_N339S rs10971809 9 33944622 [A/G] NM_018449,NM_001282529 UBAP2,UBAP2 EXON Missense_P429L,Missense_P162L rs16935299 9 33952629 [T/C] NM_018449,NM_001282529 UBAP2,UBAP2 Silent,Silent rs7869836 9 33956619 [A/G] NM_018449,NM_001282529 UBAP2,UBAP2 Silent,Silent rs307661 9 33960152 [T/G] NM_018449,NM_001282529 UBAP2,UBAP2 Silent,Silent rs10113865 9 33960219 [T/C] NM_018449,NM_001282529 UBAP2,UBAP2 Silent,Silent rs3739690 9 33971740 [A/G] NM_018449,NM_001282529 UBAP2,UBAP2 EXON Synonymous_P196P,Silent rs834029 9 33976715 [T/C] NM_018449,NM_001282529 UBAP2,UBAP2 Silent,Silent rs932969 9 34001455 [T/C] NM_018449,NM_001282529 UBAP2,UBAP2 Silent,Silent rs1785506 9 34017106 [T/C] NM_018449,NM_001282529 UBAP2,UBAP2 EXON Missense_R14Q,Silent rs7853333 9 34065659 [A/G] rs7871764 9 34071541 [T/G] rs10441723 9 34082144 [T/C] rs10971900 9 34085077 [T/G] rs7036030 9 34085859 [T/C] rs1052656 9 34087360 [T/C] NM_015397 DCAF12 EXON Silent rs11793082 9 34088701 [T/C] NM_015397 DCAF12 Silent rs7853415 9 34095717 [T/C] NM_015397 DCAF12 Silent rs4879741 9 34104443 [T/C] NM_015397 DCAF12 Silent rs10511915 9 34107310 [A/G] NM_015397 DCAF12 Silent rs1378 9 34107504 [T/C] NM_015397 DCAF12 EXON Synonymous_R131R rs11788468 9 34115076 [T/C] NM_015397 DCAF12 Silent rs2275003 9 34124860 [A/G] NM_015397 DCAF12 Silent rs2297609 9 34126788 [T/G] rs10971942 9 34127763 [A/C] rs7848924 9 34152277 [A/G] rs12376762 9 34159144 [A/G] rs7042499 9 34162975 [A/G] rs7018487 9 34167733 [T/G] rs2769710 9 34170980 [A/G] rs1041251 9 34187354 [T/C] NM_001171203,NM_001171202,NM_001171201,NM_016525,NR_033243,NM_001171204 UBAP1,UBAP1,UBAP1,UBAP1,UBAP1,UBAP1 Silent,Silent,Silent,Silent,Silent,Silent rs10971988 9 34197250 [T/C] NM_001171203,NM_001171202,NM_001171201,NM_016525,NR_033243,NM_001171204 UBAP1,UBAP1,UBAP1,UBAP1,UBAP1,UBAP1 Silent,Silent,Silent,Silent,Silent,Silent rs2094998 9 34198916 [T/G] NM_001171203,NM_001171202,NM_001171201,NM_016525,NR_033243,NM_001171204 UBAP1,UBAP1,UBAP1,UBAP1,UBAP1,UBAP1 Silent,Silent,Silent,Silent,Silent,Silent rs4879760 9 34208138 [A/G] NM_001171203,NM_001171202,NM_001171201,NM_016525,NR_033243,NM_001171204 UBAP1,UBAP1,UBAP1,UBAP1,UBAP1,UBAP1 Silent,Silent,Silent,Silent,Silent,Silent rs10971998 9 34209859 [T/C] NM_001171203,NM_001171202,NM_001171201,NM_016525,NR_033243,NM_001171204 UBAP1,UBAP1,UBAP1,UBAP1,UBAP1,UBAP1 Silent,Silent,Silent,Silent,Silent,Silent rs16935434 9 34210316 [A/G] NM_001171203,NM_001171202,NM_001171201,NM_016525,NR_033243,NM_001171204 UBAP1,UBAP1,UBAP1,UBAP1,UBAP1,UBAP1 Silent,Silent,Silent,Silent,Silent,Silent rs4319185 9 34210872 [T/C] NM_001171203,NM_001171202,NM_001171201,NM_016525,NR_033243,NM_001171204 UBAP1,UBAP1,UBAP1,UBAP1,UBAP1,UBAP1 Silent,Silent,Silent,Silent,Silent,Silent rs10972003 9 34213548 [T/C] NM_001171203,NM_001171202,NM_001171201,NM_016525,NR_033243,NM_001171204 UBAP1,UBAP1,UBAP1,UBAP1,UBAP1,UBAP1 Silent,Silent,Silent,Silent,Silent,Silent rs10972013 9 34237044 [T/C] NM_001171203,NM_001171202,NM_001171201,NM_016525,NR_033243,NM_001171204 UBAP1,UBAP1,UBAP1,UBAP1,UBAP1,UBAP1 Silent,Silent,Silent,Silent,Silent,Silent rs12335617 9 34240205 [T/G] NM_001171203,NM_001171202,NM_001171201,NM_016525,NR_033243,NM_001171204 UBAP1,UBAP1,UBAP1,UBAP1,UBAP1,UBAP1 Silent,Silent,Silent,Silent,Silent,Silent rs4008745 9 34244227 [A/G] NM_001171203,NM_001171202,NM_001171201,NM_016525,NR_033243,NM_001171204 UBAP1,UBAP1,UBAP1,UBAP1,UBAP1,UBAP1 Silent,Silent,Silent,Silent,Silent,Silent rs10972019 9 34245568 [T/C] NM_001171203,NM_001171202,NM_001171201,NM_016525,NR_033243,NM_001171204 UBAP1,UBAP1,UBAP1,UBAP1,UBAP1,UBAP1 Silent,Silent,Silent,Silent,Silent,Silent rs1049567 9 34252127 [T/C] NM_001171203,NM_001171202,NM_001171201,NM_016525,NR_033243,NM_001171204 UBAP1,UBAP1,UBAP1,UBAP1,UBAP1,UBAP1 EXON Silent,Silent,Silent,Silent,Silent,Silent rs17258783 9 34253097 [T/C] NM_194313 KIF24 EXON Silent rs4574933 9 34253488 [A/G] NM_194313 KIF24 EXON Silent rs10972023 9 34253720 [T/C] NM_194313 KIF24 EXON Silent rs10814083 9 34256347 [T/C] NM_194313 KIF24 EXON Synonymous_G1086G rs2890545 9 34277053 [T/C] NM_194313 KIF24 Silent rs17350373 9 34284944 [A/G] NM_194313 KIF24 Silent rs11790773 9 34290407 [T/C] NM_194313 KIF24 Silent rs10972043 9 34300938 [T/C] NM_194313 KIF24 Silent rs10972047 9 34310357 [A/G] NM_194313 KIF24 Silent rs10972048 9 34310927 [T/C] NM_194313 KIF24 EXON Missense_M140V rs9696517 9 34316467 [A/G] NM_194313 KIF24 Silent rs7040339 9 34327530 [T/C] NM_194313 KIF24 Silent rs11788425 9 34333855 [A/G] NM_001161,NM_147172,NM_147173,NM_001244390 NUDT2,NUDT2,NUDT2,NUDT2 Silent,Silent,Silent,Silent rs16935536 9 34334126 [A/G] NM_001161,NM_147172,NM_147173,NM_001244390 NUDT2,NUDT2,NUDT2,NUDT2 Silent,Silent,Silent,Silent rs10972067 9 34342634 [A/G] NM_001161,NM_147172,NM_147173,NM_001244390 NUDT2,NUDT2,NUDT2,NUDT2 Silent,Silent,Silent,Silent rs10972072 9 34348743 [A/C] rs10511918 9 34365357 [T/C] rs10972084 9 34373041 [T/C] NM_020702 MYORG Silent rs3737242 9 34379692 [T/C] NM_147169,NM_147168,NM_032596,NM_001252195 C9orf24,C9orf24,C9orf24,C9orf24 EXON Missense_C61Y,Synonymous_V112V,Synonymous_V247V,Missense_C114Y rs3808876 9 34382726 [A/G] NM_032596 C9orf24 Silent rs10972090 9 34386011 [T/C] NM_032596 C9orf24 Silent rs10758257 9 34387524 [A/C] NM_032596 C9orf24 Silent rs4879784 9 34390330 [T/G] NM_032596 C9orf24 Silent rs7043224 9 34393422 [T/G] NM_032596 C9orf24 Silent rs3933343 9 34395816 [A/C] NM_032596 C9orf24 Silent rs4879785 9 34396346 [A/G] NM_032596 C9orf24 Silent rs1002352 9 34399002 [A/C] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A EXON Silent,Silent,Silent,Silent,Silent,Silent rs885048 9 34399338 [A/G] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A EXON Silent,Silent,Silent,Silent,Silent,Silent rs2275262 9 34401764 [T/C] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A Silent,Silent,Silent,Silent,Silent,Silent rs10115705 9 34406384 [A/G] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A Silent,Silent,Silent,Silent,Silent,Silent rs946847 9 34408204 [T/G] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A Silent,Silent,Silent,Silent,Silent,Silent rs11788070 9 34415648 [T/C] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A Silent,Silent,Silent,Silent,Silent,Silent rs10972104 9 34419581 [T/C] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A Silent,Silent,Silent,Silent,Silent,Silent rs11788370 9 34421215 [T/C] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A Silent,Silent,Silent,Silent,Silent,Silent rs13297645 9 34422185 [A/G] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A Silent,Silent,Silent,Silent,Silent,Silent rs4590517 9 34423498 [T/C] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A Silent,Silent,Silent,Silent,Silent,Silent rs10814110 9 34423806 [T/C] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A Silent,Silent,Silent,Silent,Silent,Silent rs10972107 9 34426982 [A/G] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A Silent,Silent,Silent,Silent,Silent,Silent rs4256660 9 34431079 [T/C] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A Silent,Silent,Silent,Silent,Silent,Silent rs2077403 9 34437469 [A/G] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A Silent,Silent,Silent,Silent,Silent,Silent rs10814111 9 34457852 [A/C] NM_001184941,NM_001184942,NM_147202,NM_001184940,NM_001184945,NM_001184943 FAM219A,FAM219A,FAM219A,FAM219A,FAM219A,FAM219A Silent,Silent,Silent,Silent,Silent,Silent rs10125115 9 34464433 [T/C] NM_001281428,NM_012144 DNAI1,DNAI1 Silent,Silent rs10117513 9 34466845 [A/C] NM_001281428,NM_012144 DNAI1,DNAI1 Silent,Silent rs10972129 9 34467119 [A/G] NM_001281428,NM_012144 DNAI1,DNAI1 Silent,Silent rs4879795 9 34469025 [A/G] NM_001281428,NM_012144 DNAI1,DNAI1 Silent,Silent rs16931549 9 34485237 [T/C] NM_001281428,NM_012144 DNAI1,DNAI1 EXON Missense_A60V,Missense_A60V rs3818577 9 34489437 [A/G] NM_001281428,NM_012144 DNAI1,DNAI1 EXON Synonymous_E126E,Synonymous_E126E rs3793472 9 34492213 [A/G] NM_001281428,NM_012144 DNAI1,DNAI1 Silent,Silent rs11793196 9 34500821 [A/G] NM_001281428,NM_012144 DNAI1,DNAI1 EXON Missense_V339I,Missense_V335I rs10814116 9 34500879 [T/C] NM_001281428,NM_012144 DNAI1,DNAI1 Silent,Silent rs10511917 9 34504634 [A/G] NM_001281428,NM_012144 DNAI1,DNAI1 Silent,Silent rs4879801 9 34509746 [A/G] NM_001281428,NM_012144 DNAI1,DNAI1 Silent,Silent rs17353380 9 34512893 [A/G] NM_001281428,NM_012144 DNAI1,DNAI1 Silent,Silent VG09S31849 9 34513163 [A/G] NM_001281428,NM_012144 DNAI1,DNAI1 EXON Missense_G519S,Missense_G515S rs12002889 9 34515101 [A/G] NM_001281428,NM_012144 DNAI1,DNAI1 Silent,Silent rs12001113 9 34515328 [T/C] NM_001281428,NM_012144 DNAI1,DNAI1 Silent,Silent rs1111375 9 34521148 [A/G] NM_198573 ENHO EXON Silent rs35331204 9 34526441 [T/C] rs10114507 9 34536873 [T/C] rs4878578 9 34540065 [T/C] rs4879803 9 34545932 [T/G] rs4395980 9 34548009 [T/C] rs10814119 9 34550295 [T/C] rs4879804 9 34550830 [A/G] rs1077962 9 34554634 [A/G] NM_001842,NM_147164,NM_001207011 CNTFR,CNTFR,CNTFR Silent,Silent,Silent rs7044318 9 34554999 [T/C] NM_001842,NM_147164,NM_001207011 CNTFR,CNTFR,CNTFR Silent,Silent,Silent rs12552724 9 34555481 [T/C] NM_001842,NM_147164,NM_001207011 CNTFR,CNTFR,CNTFR Silent,Silent,Silent rs12553466 9 34557313 [A/G] NM_001842,NM_147164,NM_001207011 CNTFR,CNTFR,CNTFR Silent,Silent,Silent rs10972149 9 34561160 [A/G] NM_001842,NM_147164,NM_001207011 CNTFR,CNTFR,CNTFR Silent,Silent,Silent rs10814123 9 34561808 [T/C] NM_001842,NM_147164,NM_001207011 CNTFR,CNTFR,CNTFR Silent,Silent,Silent rs4879805 9 34564274 [A/G] NM_001842,NM_147164,NM_001207011 CNTFR,CNTFR,CNTFR Silent,Silent,Silent rs10738931 9 34565781 [A/G] NM_001842,NM_147164,NM_001207011 CNTFR,CNTFR,CNTFR Silent,Silent,Silent rs3802428 9 34567200 [A/C] NM_001842,NM_147164,NM_001207011 CNTFR,CNTFR,CNTFR Silent,Silent,Silent rs10758268 9 34572767 [T/G] NM_001842,NM_147164,NM_001207011,NR_024369 CNTFR,CNTFR,CNTFR,CNTFR-AS1 Silent,Silent,Silent,Silent rs1571401 9 34572815 [T/C] NM_001842,NM_147164,NM_001207011,NR_024369 CNTFR,CNTFR,CNTFR,CNTFR-AS1 Silent,Silent,Silent,Silent rs4879806 9 34575810 [A/G] NM_001842,NM_147164,NM_001207011,NR_024369 CNTFR,CNTFR,CNTFR,CNTFR-AS1 Silent,Silent,Silent,Silent rs1080750 9 34581525 [T/C] NM_001842,NM_147164,NM_001207011,NR_024369 CNTFR,CNTFR,CNTFR,CNTFR-AS1 Silent,Silent,Silent,Silent rs3763615 9 34584105 [T/C] NM_001842,NM_147164,NM_001207011 CNTFR,CNTFR,CNTFR Silent,Silent,Silent rs3763613 9 34584319 [T/G] NM_001842,NM_147164,NM_001207011 CNTFR,CNTFR,CNTFR Silent,Silent,Silent rs7037232 9 34587485 [T/C] NM_001842,NM_147164,NM_001207011 CNTFR,CNTFR,CNTFR Silent,Silent,Silent rs7036351 9 34592699 [T/C] rs16931689 9 34607766 [A/G] rs7032127 9 34610330 [T/C] rs12003899 9 34610643 [T/C] NM_148178,NM_148179 RPP25L,RPP25L EXON Silent,Silent rs10972167 9 34619262 [A/G] NM_001281427,NM_007234,NM_001281425,NM_001281426,NM_024348 DCTN3,DCTN3,DCTN3,DCTN3,DCTN3 Silent,Silent,Silent,Silent,Silent rs10814127 9 34619397 [A/G] NM_001281427,NM_007234,NM_001281425,NM_001281426,NM_024348 DCTN3,DCTN3,DCTN3,DCTN3,DCTN3 Silent,Silent,Silent,Silent,Silent rs10972168 9 34619621 [A/G] NM_001281427,NM_007234,NM_001281425,NM_001281426,NM_024348 DCTN3,DCTN3,DCTN3,DCTN3,DCTN3 Silent,Silent,Silent,Silent,Silent rs10972170 9 34619888 [T/C] NM_001281427,NM_007234,NM_001281425,NM_001281426,NM_024348 DCTN3,DCTN3,DCTN3,DCTN3,DCTN3 Silent,Silent,Silent,Silent,Silent rs10814129 9 34623718 [A/G] NM_001017363 ARID3C Silent rs10972175 9 34625409 [A/G] NM_001017363 ARID3C Silent rs12343216 9 34626819 [T/C] NM_001017363 ARID3C Silent rs12553321 9 34627333 [T/C] NM_001017363 ARID3C Silent rs10046843 9 34631159 [T/C] rs11791806 9 34633529 [T/C] rs12115673 9 34636112 [T/C] NM_001282205,NM_147157,NM_001282206,NM_001282208,NM_001282209,NM_005866,NR_104108,NM_001282207 SIGMAR1,SIGMAR1,SIGMAR1,SIGMAR1,SIGMAR1,SIGMAR1,SIGMAR1,SIGMAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10814130 9 34637991 [A/C] rs2277202 9 34648020 [A/G] NM_001258332,NM_000155 GALT,GALT Silent,Silent rs2070075 9 34648418 [T/C] NM_001258332,NM_000155 GALT,GALT EXON Synonymous_L109L,Synonymous_L218L rs1055607 9 34649050 [A/G] NM_001258332,NM_000155 GALT,GALT EXON Synonymous_T183T,Synonymous_T292T rs2070074 9 34649442 [A/G] NM_001258332,NM_000155 GALT,GALT EXON Missense_N205D,Missense_N314D rs1061758 9 34652330 [A/G] NM_001142784 IL11RA Silent rs11575585 9 34653994 [A/G] NM_001142784,NR_052010 IL11RA,IL11RA EXON Silent,Silent rs3808868 9 34654142 [T/G] NM_001142784,NR_052010 IL11RA,IL11RA Silent,Silent rs2812357 9 34655436 [T/C] NM_001142784,NR_052010 IL11RA,IL11RA Silent,Silent rs11575580 9 34660864 [T/C] NM_001142784,NR_052010 IL11RA,IL11RA EXON Missense_R395W,Silent rs11336 9 34661678 [T/C] NM_001142784,NR_052010 IL11RA,IL11RA EXON Silent,Silent rs11575584 9 34661994 [A/G] NM_006664 CCL27 EXON Missense_L96F rs11575594 9 34662048 [T/C] NM_006664 CCL27 EXON Missense_I78V rs913835 9 34664488 [A/G] NM_001320037,NR_135148,NM_001320038 LOC730098,LOC730098,LOC730098 EXON Silent,Silent,Silent rs2492365 9 34672119 [T/C] rs2772554 9 34680853 [A/C] rs2772559 9 34686157 [T/C] rs7032259 9 34700716 [T/C] rs10972201 9 34707373 [A/G] rs10972203 9 34708899 [A/G] rs2812378 9 34710260 [A/G] rs11574914 9 34710338 [A/G] rs2812377 9 34710450 [A/C] rs10124246 9 34713129 [T/G] rs16931802 9 34718166 [T/C] rs10814138 9 34723035 [A/C] rs2297132 9 34723181 [A/G] NM_001141917 FAM205A EXON Silent rs7035198 9 34727831 [A/G] NM_001141917 FAM205A Silent rs2812344 9 34730015 [T/C] rs7024727 9 34730395 [T/G] rs2812373 9 34741752 [T/C] rs12346708 9 34759890 [T/G] rs36091416 9 34768441 [A/G] rs13293020 9 34768693 [T/C] rs13294495 9 34770746 [A/C] rs277580 9 34771875 [A/G] rs277579 9 34772268 [A/G] rs277595 9 34778450 [A/G] rs277608 9 34783711 [A/G] rs277607 9 34784168 [A/G] rs277606 9 34785308 [T/C] rs277604 9 34786159 [A/G] rs4879828 9 34795035 [T/G] rs2890604 9 34799535 [T/C] rs1411207 9 34803230 [T/C] rs277558 9 34807277 [A/G] rs10814157 9 34811270 [A/G] rs7850527 9 34812795 [A/G] rs277583 9 34823809 [T/C] rs4879832 9 34830432 [T/C] NR_024481 FAM205BP EXON Silent rs3802426 9 34836905 [A/G] NR_024481 FAM205BP Silent rs924565 9 34839291 [A/G] rs10814165 9 34843372 [A/G] rs1566598 9 34866054 [T/C] rs16932009 9 34866726 [T/C] rs1566595 9 34866989 [T/C] rs1948745 9 34867913 [A/G] rs1115604 9 34871878 [T/C] rs276671 9 34895598 [A/C] NM_001309427,NM_001309426 FAM205C,FAM205C EXON Missense_V41G,Missense_V41G rs276672 9 34895767 [A/G] NM_001309427,NM_001309426 FAM205C,FAM205C EXON Silent,Silent rs2782403 9 34910344 [A/G] rs7033016 9 34911879 [T/C] rs686400 9 34911949 [T/C] rs2050362 9 34914379 [A/G] rs4879836 9 34918201 [A/G] rs2173897 9 34920429 [T/C] rs16935687 9 34922680 [A/G] rs10972262 9 34935155 [T/G] rs7041922 9 34938198 [T/C] rs10283808 9 34942073 [T/C] rs7031962 9 34957613 [A/G] NM_001304333,NR_136307,NM_001347982 PHF24,PHF24,PHF24 EXON Silent,Silent,Silent rs7874491 9 34966220 [T/C] NM_001304333,NR_136307,NM_001347982,NM_001347983,NR_136308,NM_015297 PHF24,PHF24,PHF24,PHF24,PHF24,PHF24 Silent,Silent,Silent,Silent,Silent,Silent rs16932097 9 34970197 [T/C] NM_001304333,NR_136307,NM_001347982,NM_001347983,NR_136308,NM_015297 PHF24,PHF24,PHF24,PHF24,PHF24,PHF24 Silent,Silent,Silent,Silent,Silent,Silent rs3739873 9 34978431 [A/G] NM_001304333,NR_136307,NM_001347982,NM_001347983,NR_136308,NM_015297 PHF24,PHF24,PHF24,PHF24,PHF24,PHF24 EXON Silent,Silent,Silent,Silent,Silent,Silent rs2298311 9 34979935 [T/C] NM_001304333,NR_136307,NM_001347982,NM_001347983,NR_136308,NM_015297 PHF24,PHF24,PHF24,PHF24,PHF24,PHF24 EXON Silent,Silent,Silent,Silent,Silent,Silent rs16932121 9 34980373 [A/C] NM_001304333,NR_136307,NM_001347982,NM_001347983,NR_136308,NM_015297 PHF24,PHF24,PHF24,PHF24,PHF24,PHF24 EXON Silent,Silent,Silent,Silent,Silent,Silent rs3739875 9 34980998 [A/C] NM_001304333,NR_136307,NM_001347982,NM_001347983,NR_136308,NM_015297 PHF24,PHF24,PHF24,PHF24,PHF24,PHF24 EXON Silent,Silent,Silent,Silent,Silent,Silent rs3849915 9 34982200 [T/C] NM_001304333,NR_136307,NM_001347982,NM_001347983,NR_136308,NM_015297 PHF24,PHF24,PHF24,PHF24,PHF24,PHF24 EXON Silent,Silent,Silent,Silent,Silent,Silent rs3849916 9 34982317 [T/C] NM_001304333,NR_136307,NM_001347982,NM_001347983,NR_136308,NM_015297 PHF24,PHF24,PHF24,PHF24,PHF24,PHF24 EXON Silent,Silent,Silent,Silent,Silent,Silent rs3088305 9 34982343 [A/G] NM_001304333,NR_136307,NM_001347982,NM_001347983,NR_136308,NM_015297 PHF24,PHF24,PHF24,PHF24,PHF24,PHF24 EXON Silent,Silent,Silent,Silent,Silent,Silent rs13293550 9 34983190 [T/C] rs4879847 9 34983974 [T/C] rs3808867 9 34989545 [T/C] rs4879849 9 34996014 [A/C] NM_001349724,NM_001135004,NM_012266,NM_001349723,NM_001349725,NM_001135005 DNAJB5,DNAJB5,DNAJB5,DNAJB5,DNAJB5,DNAJB5 Silent,Silent,Silent,Silent,Silent,Silent rs9608 9 34998003 [A/G] NM_001349724,NM_001135004,NM_012266,NM_001349723,NM_001349725,NM_001135005 DNAJB5,DNAJB5,DNAJB5,DNAJB5,DNAJB5,DNAJB5 EXON Silent,Silent,Silent,Silent,Silent,Silent rs10814192 9 34999992 [A/G] rs10972278 9 35000289 [A/G] rs10972281 9 35010738 [T/C] rs4879852 9 35011305 [T/C] rs10972291 9 35031343 [A/G] rs10491510 9 35040245 [T/C] rs10972297 9 35041604 [T/C] NM_001040412,NM_001040411 C9orf131,C9orf131 Silent,Silent rs615474 9 35043291 [T/G] NM_001040412,NM_001040411,NM_001040410,NM_203299,NM_001287391 C9orf131,C9orf131,C9orf131,C9orf131,C9orf131 EXON Missense_W174L,Missense_W149L,Missense_W187L,Missense_W222L,Missense_W149L rs3739871 9 35045372 [T/C] NM_001040412,NM_001040411,NM_001040410,NM_203299,NM_001287391 C9orf131,C9orf131,C9orf131,C9orf131,C9orf131 EXON Missense_P868S,Missense_P843S,Missense_P881S,Missense_P916S,Missense_P843S rs3824552 9 35045693 [A/C] NM_001040412,NM_001040411,NM_001040410,NM_203299,NM_001287391 C9orf131,C9orf131,C9orf131,C9orf131,C9orf131 EXON Synonymous_R975R,Synonymous_R950R,Synonymous_R988R,Synonymous_R1023R,Synonymous_R950R rs7048389 9 35049508 [T/C] rs642296 9 35051269 [T/C] rs565070 9 35054586 [A/G] rs595429 9 35055669 [T/C] rs514492 9 35062972 [T/C] NM_007126,NM_001354928,NM_001354927 VCP,VCP,VCP Silent,Silent,Silent rs10972300 9 35068201 [T/C] NM_007126,NM_001354928,NM_001354927 VCP,VCP,VCP Silent,Silent,Silent rs2073576 9 35068948 [T/C] NM_007126,NM_001354928,NM_001354927 VCP,VCP,VCP Silent,Silent,Silent rs17885597 9 35073329 [T/C] rs17878564 9 35073854 [T/C] NM_004629 FANCG EXON Silent rs587118 9 35074917 [T/C] NM_004629 FANCG Silent rs4986939 9 35075969 [A/G] NM_004629 FANCG EXON Missense_S378L rs4986940 9 35076517 [A/G] NM_004629 FANCG EXON Missense_P330S rs2237857 9 35076755 [A/G] NM_004629 FANCG EXON Missense_T297I rs527459 9 35088142 [A/G] rs556766 9 35089048 [A/C] NM_032634,NM_001201484,NM_152850 PIGO,PIGO,PIGO EXON Silent,Silent,Silent rs12006467 9 35090720 [T/C] NM_032634,NM_001201484,NM_152850 PIGO,PIGO,PIGO Silent,Silent,Silent rs527365 9 35098155 [T/C] rs664357 9 35100002 [T/C] NM_001287032,NM_001287031,NM_001287033,NM_013442 STOML2,STOML2,STOML2,STOML2 EXON Silent,Silent,Silent,Silent rs666549 9 35100468 [T/C] NM_001287032,NM_001287031,NM_001287033,NM_013442 STOML2,STOML2,STOML2,STOML2 Silent,Silent,Silent,Silent rs586017 9 35100569 [A/G] NM_001287032,NM_001287031,NM_001287033,NM_013442 STOML2,STOML2,STOML2,STOML2 Silent,Silent,Silent,Silent rs2298309 9 35102743 [T/C] NM_001287032,NM_001287031,NM_001287033,NM_013442 STOML2,STOML2,STOML2,STOML2 EXON Silent,Synonymous_V41V,Silent,Synonymous_V41V rs10972316 9 35106987 [T/C] NM_001317991,NM_025182,NR_134455 FAM214B,FAM214B,FAM214B Silent,Silent,Silent rs7039828 9 35107858 [T/C] NM_001317991,NM_025182,NR_134455 FAM214B,FAM214B,FAM214B EXON Synonymous_S138S,Synonymous_S138S,Silent rs944700 9 35109949 [A/G] NM_001317991,NM_025182,NR_134455 FAM214B,FAM214B,FAM214B Silent,Silent,Silent rs10972320 9 35112406 [A/G] NM_025182,NR_134455 FAM214B,FAM214B Silent,Silent rs7852999 9 35114394 [A/G] NM_025182,NR_134455 FAM214B,FAM214B Silent,Silent rs10123856 9 35114614 [A/G] NM_025182,NR_134455 FAM214B,FAM214B Silent,Silent rs10972321 9 35116932 [A/G] rs1571953 9 35121795 [T/C] rs2381298 9 35123369 [A/G] rs4879869 9 35141508 [T/C] rs10972341 9 35141705 [A/G] rs10972351 9 35149993 [A/G] rs13293564 9 35166763 [T/G] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs4879876 9 35171905 [A/G] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs7865406 9 35177345 [A/G] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs3904435 9 35191713 [T/C] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs11531752 9 35192366 [T/C] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs10972381 9 35208145 [T/C] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs10972390 9 35231047 [T/C] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs10118130 9 35250666 [A/G] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs10114937 9 35271817 [T/C] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs10758303 9 35289544 [A/G] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs4419897 9 35290205 [A/G] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs10217739 9 35293752 [T/C] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs10972428 9 35302950 [T/C] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs572527 9 35307408 [A/C] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs2069008 9 35343563 [A/C] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs10814231 9 35361044 [A/G] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs12352480 9 35364353 [A/G] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs12684897 9 35369125 [T/C] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs7024251 9 35369888 [A/G] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs2149368 9 35374982 [A/G] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs2281999 9 35381504 [T/C] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs12339582 9 35398900 [T/G] NM_001330653,NM_006377 UNC13B,UNC13B EXON Missense_E1232D,Missense_E1232D rs4878613 9 35400272 [A/G] NM_001330653,NM_006377 UNC13B,UNC13B Silent,Silent rs12726 9 35404840 [A/G] NM_001330653,NM_006377 UNC13B,UNC13B EXON Silent,Silent rs12238748 9 35410334 [T/C] NR_003582,NR_110320,NR_003581 ATP8B5P,ATP8B5P,ATP8B5P Silent,Silent,Silent rs4878615 9 35413694 [T/C] NR_003582,NR_110320,NR_003581 ATP8B5P,ATP8B5P,ATP8B5P Silent,Silent,Silent rs10972462 9 35427324 [A/G] NR_003582,NR_110320,NR_003581 ATP8B5P,ATP8B5P,ATP8B5P Silent,Silent,Silent rs7864635 9 35444482 [T/C] NR_003582,NR_110320,NR_003581 ATP8B5P,ATP8B5P,ATP8B5P Silent,Silent,Silent rs9298963 9 35446386 [T/G] NR_003582,NR_110320,NR_003581 ATP8B5P,ATP8B5P,ATP8B5P Silent,Silent,Silent rs16932435 9 35450097 [A/G] NR_003582,NR_110320,NR_003581 ATP8B5P,ATP8B5P,ATP8B5P EXON Silent,Silent,Silent rs4879899 9 35452398 [A/C] NR_003581 ATP8B5P Silent rs1971100 9 35460769 [T/G] NR_003581 ATP8B5P Silent rs9298964 9 35465408 [A/G] NR_003581 ATP8B5P Silent rs7040391 9 35480564 [T/C] NR_003581 ATP8B5P Silent rs7875285 9 35482075 [T/C] NR_003581 ATP8B5P EXON Silent rs10972487 9 35482149 [T/C] NR_003581 ATP8B5P EXON Silent rs7018605 9 35482764 [T/G] NR_003581 ATP8B5P EXON Silent rs10972488 9 35489274 [A/C] rs7870832 9 35497219 [T/C] NM_001330740,NM_014806,NR_052015 RUSC2,RUSC2,RUSC2 Silent,Silent,Silent rs1890591 9 35500545 [A/G] NM_001330740,NM_014806,NR_052015 RUSC2,RUSC2,RUSC2 Silent,Silent,Silent rs10972498 9 35514653 [T/C] NM_001330740,NM_014806,NR_052015 RUSC2,RUSC2,RUSC2 Silent,Silent,Silent rs4879901 9 35518997 [T/C] NM_001330740,NM_014806,NR_052015 RUSC2,RUSC2,RUSC2 Silent,Silent,Silent rs7047617 9 35522318 [T/C] NM_001330740,NM_014806,NR_052015 RUSC2,RUSC2,RUSC2 Silent,Silent,Silent rs2115983 9 35526605 [T/G] NM_001330740,NM_014806,NR_052015 RUSC2,RUSC2,RUSC2 Silent,Silent,Silent rs10972503 9 35532053 [T/C] NM_001330740,NM_014806,NR_052015 RUSC2,RUSC2,RUSC2 Silent,Silent,Silent rs10972504 9 35532091 [A/G] NM_001330740,NM_014806,NR_052015 RUSC2,RUSC2,RUSC2 Silent,Silent,Silent rs7041770 9 35533348 [T/C] NM_001330740,NM_014806,NR_052015 RUSC2,RUSC2,RUSC2 Silent,Silent,Silent rs10814252 9 35551434 [A/G] NM_001330740,NM_014806,NR_052015,NM_001135999 RUSC2,RUSC2,RUSC2,RUSC2 Silent,Silent,Silent,Silent rs1890590 9 35557696 [T/G] NM_001330740,NM_014806,NR_052015,NM_001135999 RUSC2,RUSC2,RUSC2,RUSC2 Silent,Silent,Silent,Silent rs17371767 9 35557734 [A/G] NM_001330740,NM_014806,NR_052015,NM_001135999 RUSC2,RUSC2,RUSC2,RUSC2 Silent,Silent,Silent,Silent rs12338773 9 35559905 [T/C] NM_001330740,NM_014806,NR_052015,NM_001135999 RUSC2,RUSC2,RUSC2,RUSC2 Silent,Silent,Silent,Silent rs755774 9 35562549 [A/G] NM_001164310,NM_001287239,NM_001099951,NM_001287238 FAM166B,FAM166B,FAM166B,FAM166B EXON Synonymous_C189C,Silent,Silent,Silent rs4879907 9 35566752 [T/C] rs1991624 9 35574609 [T/G] rs10758312 9 35578001 [A/G] rs7849006 9 35592324 [A/C] rs10814259 9 35601967 [A/C] rs2275422 9 35606884 [A/G] NM_001318230,NM_006285 TESK1,TESK1 EXON Missense_C15Y,Synonymous_L147L rs3750429 9 35610055 [T/C] NM_001782 CD72 EXON Silent rs4879913 9 35610912 [A/G] NM_001782 CD72 Silent rs34791102 9 35612978 [A/G] NM_001782 CD72 EXON Missense_P234L rs16932509 9 35615581 [T/C] NM_001782 CD72 Silent rs10814260 9 35618523 [A/G] rs10972530 9 35628739 [A/G] rs10972531 9 35631423 [T/C] rs1890592 9 35635683 [T/G] rs10972540 9 35641859 [T/C] rs17466775 9 35643558 [A/G] rs2153240 9 35648008 [A/G] rs3138083 9 35648950 [A/G] rs3138082 9 35649216 [T/C] rs2297880 9 35650458 [A/G] NM_014450 SIT1 Silent rs10441725 9 35659591 [T/C] NM_001195201,NM_001195200,NM_174923,NM_001195217,NM_032818 CCDC107,CCDC107,CCDC107,CCDC107,ARHGEF39 EXON Silent,Silent,Silent,Silent,Silent rs2275420 9 35660901 [T/C] NM_001195201,NM_001195200,NM_174923,NM_001195217,NM_032818 CCDC107,CCDC107,CCDC107,CCDC107,ARHGEF39 EXON Silent,Silent,Missense_S190F,Silent,Silent rs1339374 9 35660990 [A/G] NM_001195201,NM_001195200,NM_174923,NM_001195217,NM_032818 CCDC107,CCDC107,CCDC107,CCDC107,ARHGEF39 EXON Silent,Missense_I193V,Missense_I220V,Silent,Silent rs10441686 9 35661088 [A/G] NM_001195201,NM_001195200,NM_174923,NM_001195217,NM_032818 CCDC107,CCDC107,CCDC107,CCDC107,ARHGEF39 EXON Silent,Synonymous_R225R,Synonymous_R252R,Silent,Silent rs10972554 9 35661379 [A/G] NM_001195201,NM_001195200,NM_174923,NM_001195217,NM_032818 CCDC107,CCDC107,CCDC107,CCDC107,ARHGEF39 EXON Silent,Silent,Silent,Silent,Silent rs2297879 9 35662251 [T/C] NM_032818 ARHGEF39 EXON Missense_H306R rs1934158 9 35671627 [T/G] rs2071675 9 35673891 [A/G] rs2071676 9 35674053 [A/G] NM_001216 CA9 EXON Missense_V33M rs2857802 9 35679061 [T/C] NM_001216 CA9 Silent rs3829078 9 35679251 [A/G] NM_001216 CA9 EXON Missense_Q326R rs3750433 9 35680564 [A/G] NM_001216 CA9 Silent rs1538535 9 35681299 [T/C] rs4879924 9 35681368 [T/C] rs17259350 9 35682585 [T/C] NM_001301226,NM_213674 TPM2,TPM2 Silent,Silent rs760402 9 35686376 [A/G] NM_001301226,NM_213674,NM_001301227,NM_003289 TPM2,TPM2,TPM2,TPM2 Silent,Silent,Silent,Silent rs2145925 9 35689373 [T/C] NM_001301226,NM_213674,NM_001301227,NM_003289 TPM2,TPM2,TPM2,TPM2 Silent,Silent,Silent,Silent rs2756892 9 35690310 [T/C] rs1885373 9 35696802 [T/C] rs2295794 9 35700150 [T/C] NM_006289 TLN1 Silent rs4879926 9 35700837 [T/C] NM_006289 TLN1 Silent rs867194 9 35705086 [A/G] NM_006289 TLN1 Silent rs28664652 9 35706334 [T/C] NM_006289 TLN1 EXON Synonymous_P1740P rs2295795 9 35712003 [A/G] NM_006289 TLN1 EXON Missense_S1227L rs3763630 9 35731004 [T/C] NM_006289 TLN1 Silent rs12340601 9 35733970 [A/C] NM_006368 CREB3 Silent rs10814274 9 35734956 [T/C] NM_006368 CREB3 Silent rs34745689 9 35736099 [T/C] NM_006368 CREB3 EXON Synonymous_N222N rs13287359 9 35737006 [A/G] NM_001330660,NM_020944 GBA2,GBA2 EXON Silent,Silent rs1570246 9 35748806 [T/G] NM_001330660,NM_020944 GBA2,GBA2 EXON Silent,Silent rs1570248 9 35751221 [T/C] NM_001080496 RGP1 Silent rs1570249 9 35752252 [A/G] NM_001080496 RGP1 Silent rs3750436 9 35753170 [A/C] NM_001080496,NM_001044264 RGP1,MSMP EXON Silent,Missense_G116V rs1951432 9 35757075 [A/G] rs10814275 9 35758578 [A/G] rs4878628 9 35766561 [T/C] rs7020142 9 35778800 [T/C] rs10972581 9 35779571 [T/C] rs7847621 9 35780220 [A/G] rs12337802 9 35789720 [T/C] rs3750438 9 35792249 [T/C] rs3793543 9 35798710 [A/G] NM_003995 NPR2 Silent rs10758325 9 35804149 [A/G] NM_003995 NPR2 Silent rs2281645 9 35809328 [A/G] NM_003995,NM_172312 NPR2,SPAG8 Silent,Silent rs878749 9 35812623 [T/G] rs4879929 9 35815356 [T/C] rs13292880 9 35817579 [A/C] NR_052026,NM_001012446 FAM221B,FAM221B EXON Silent,Silent rs2281646 9 35818647 [A/G] NR_052026,NM_001012446 FAM221B,FAM221B Silent,Silent rs734158 9 35823009 [T/C] NR_052026,NM_001012446 FAM221B,FAM221B Silent,Silent rs4879930 9 35825413 [T/C] NR_052026,NM_001012446 FAM221B,FAM221B Silent,Silent rs10738948 9 35833448 [T/C] NM_016446,NM_001042589,NM_001042590,NM_001363620,NM_001363625,NM_001363621,NM_001363622 TMEM8B,TMEM8B,TMEM8B,TMEM8B,TMEM8B,TMEM8B,TMEM8B Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2236292 9 35841071 [T/C] NM_016446,NM_001042589,NM_001042590,NM_001363620,NM_001363625,NM_001363621,NM_001363622 TMEM8B,TMEM8B,TMEM8B,TMEM8B,TMEM8B,TMEM8B,TMEM8B Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2236293 9 35841783 [A/G] NM_016446,NM_001042589,NM_001042590,NM_001363620,NM_001363625,NM_001363621,NM_001363622 TMEM8B,TMEM8B,TMEM8B,TMEM8B,TMEM8B,TMEM8B,TMEM8B EXON Silent,Silent,Missense_R434Q,Missense_R434Q,Silent,Silent,Silent rs13284995 9 35842854 [T/C] NM_016446,NM_001042589,NM_001042590,NM_001363620,NM_001363625,NM_001363621,NM_001363622 TMEM8B,TMEM8B,TMEM8B,TMEM8B,TMEM8B,TMEM8B,TMEM8B Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7035913 9 35854437 [A/C] NM_001042589,NM_001042590,NM_001363622 TMEM8B,TMEM8B,TMEM8B EXON Silent,Silent,Silent rs17204908 9 35854565 [T/C] NM_001042589,NM_001042590,NM_001363622 TMEM8B,TMEM8B,TMEM8B EXON Silent,Silent,Silent rs12345598 9 35855218 [T/G] NM_001042590,NM_001363622 TMEM8B,TMEM8B EXON Silent,Silent rs10814287 9 35860483 [T/C] NR_024006 LINC00950 EXON Silent rs11791889 9 35860942 [A/G] NR_024006 LINC00950 EXON Silent rs12552435 9 35864274 [A/G] NR_024006 LINC00950 EXON Silent rs10814288 9 35867901 [A/G] rs7039312 9 35881628 [T/C] rs4879938 9 35887412 [T/C] rs12000024 9 35892051 [A/G] rs10972610 9 35893292 [A/G] rs6476493 9 35894737 [T/C] rs12376357 9 35895999 [T/C] rs2890719 9 35903317 [A/G] rs1467577 9 35903370 [A/G] rs10814295 9 35905761 [T/C] rs2025175 9 35905966 [A/G] rs10972619 9 35908488 [A/G] rs10814297 9 35910945 [A/G] NM_001348107 SPAAR EXON Silent rs4483242 9 35918778 [T/C] rs2025174 9 35920856 [A/G] rs7046469 9 35923384 [T/G] rs2065107 9 35927129 [T/C] rs7042035 9 35931381 [A/C] rs10814300 9 35933323 [T/C] rs10814301 9 35935138 [A/C] rs10814303 9 35935963 [T/G] rs10491553 9 35941789 [A/C] rs13283964 9 35942521 [T/C] rs723425 9 35952224 [T/C] rs7857956 9 35953318 [T/G] rs10738950 9 35953983 [T/C] rs7034414 9 35954375 [A/G] rs12346655 9 35956713 [A/G] rs2233568 9 35957355 [A/G] NM_019897 OR2S2 EXON Synonymous_T247T rs732233 9 35961915 [A/G] rs4878636 9 35962782 [T/C] rs10972648 9 35966699 [A/G] rs10758338 9 35968663 [A/G] rs13292355 9 35970516 [T/C] rs12352266 9 35971579 [T/C] rs7048672 9 35975125 [A/C] rs10972658 9 35978258 [T/G] rs10972659 9 35978321 [A/C] rs7874748 9 35978632 [T/C] rs10814308 9 35983405 [T/C] rs12004566 9 35988418 [T/C] rs16932816 9 35991104 [T/C] rs16932818 9 35991115 [A/G] rs1408466 9 35992302 [T/C] rs10738955 9 35993376 [T/C] rs1535912 9 35994554 [T/G] rs7028770 9 35995777 [A/C] rs7048994 9 35996326 [T/C] rs1324461 9 35998220 [A/G] rs1324459 9 35998726 [T/C] rs10972680 9 36002881 [A/G] rs942480 9 36005428 [A/G] rs2017241 9 36013929 [T/C] rs2077559 9 36014850 [A/G] rs7029221 9 36018310 [T/G] rs6476506 9 36018752 [T/C] rs7027417 9 36023246 [A/G] rs7871017 9 36023347 [T/C] rs10814320 9 36023728 [A/G] rs7863810 9 36025452 [A/G] rs12339284 9 36028399 [A/G] rs10814323 9 36031610 [A/G] rs7873354 9 36036003 [T/C] rs7024649 9 36038361 [T/C] NM_021111,NM_001316345,NM_001316347,NM_001316346,NM_001316348 RECK,RECK,RECK,RECK,RECK Silent,Silent,Silent,Silent,Silent rs10972705 9 36040713 [A/G] NM_021111,NM_001316345,NM_001316347,NM_001316346,NM_001316348 RECK,RECK,RECK,RECK,RECK Silent,Silent,Silent,Silent,Silent rs6476514 9 36046596 [A/G] NM_021111,NM_001316345,NM_001316347,NM_001316346,NM_001316348 RECK,RECK,RECK,RECK,RECK Silent,Silent,Silent,Silent,Silent rs1324457 9 36050506 [T/G] NM_021111,NM_001316345,NM_001316347,NM_001316346,NM_001316348 RECK,RECK,RECK,RECK,RECK Silent,Silent,Silent,Silent,Silent rs7035468 9 36060451 [A/G] NM_021111,NM_001316345,NM_001316347,NM_001316346,NM_001316348 RECK,RECK,RECK,RECK,RECK Silent,Silent,Silent,Silent,Silent rs1408469 9 36066220 [A/C] NM_021111,NM_001316345,NM_001316347,NM_001316346,NM_001316348 RECK,RECK,RECK,RECK,RECK Silent,Silent,Silent,Silent,Silent rs6476519 9 36066385 [A/G] NM_021111,NM_001316345,NM_001316347,NM_001316346,NM_001316348 RECK,RECK,RECK,RECK,RECK Silent,Silent,Silent,Silent,Silent rs1324465 9 36077871 [T/C] NM_021111,NM_001316345,NM_001316347,NM_001316346,NM_001316348 RECK,RECK,RECK,RECK,RECK Silent,Silent,Silent,Silent,Silent rs16932912 9 36087876 [A/G] NM_021111,NM_001316345 RECK,RECK EXON Missense_V275I,Missense_V147I rs3736884 9 36091257 [T/C] NM_021111,NM_001316345 RECK,RECK EXON Synonymous_S334S,Synonymous_S206S rs7033405 9 36093204 [T/G] NM_021111,NM_001316345 RECK,RECK Silent,Silent rs4879952 9 36095505 [A/G] NM_021111,NM_001316345 RECK,RECK Silent,Silent rs6476527 9 36099871 [T/C] NM_021111,NM_001316345 RECK,RECK Silent,Silent rs7029444 9 36101562 [A/G] NM_021111,NM_001316345 RECK,RECK Silent,Silent rs11788747 9 36105264 [A/G] NM_021111,NM_001316345 RECK,RECK EXON Synonymous_P520P,Synonymous_P392P rs10972726 9 36109947 [A/C] NM_021111,NM_001316345 RECK,RECK Silent,Silent rs13283904 9 36113712 [T/C] NM_021111,NM_001316345 RECK,RECK Silent,Silent rs7875409 9 36128544 [A/G] rs7033900 9 36130245 [A/G] rs7869658 9 36132335 [A/G] rs10972754 9 36135424 [T/C] rs752353 9 36137346 [A/G] NR_104639,NM_001287010,NR_104638,NM_001287011,NR_104640,NR_104641,NM_001287012,NR_104637,NM_022343,NM_001287014,NM_001287013 GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs752351 9 36137513 [A/C] NR_104639,NM_001287010,NR_104638,NM_001287011,NR_104640,NR_104641,NM_001287012,NR_104637,NM_022343,NM_001287014,NM_001287013 GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11791833 9 36140115 [T/C] NR_104639,NM_001287010,NR_104638,NM_001287011,NR_104640,NR_104641,NM_001287012,NR_104637,NM_022343,NM_001287014,NM_001287013 GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17835038 9 36141514 [T/C] NR_104639,NM_001287010,NR_104638,NM_001287011,NR_104640,NR_104641,NM_001287012,NR_104637,NM_022343,NM_001287014,NM_001287013 GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1571268 9 36141635 [A/G] NR_104639,NM_001287010,NR_104638,NM_001287011,NR_104640,NR_104641,NM_001287012,NR_104637,NM_022343,NM_001287014,NM_001287013 GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16932990 9 36143566 [A/G] NR_104639,NM_001287010,NR_104638,NM_001287011,NR_104640,NR_104641,NM_001287012,NR_104637,NM_022343,NM_001287014,NM_001287013 GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12347093 9 36145427 [T/C] NR_104639,NM_001287010,NR_104638,NM_001287011,NR_104640,NR_104641,NM_001287012,NR_104637,NM_022343,NM_001287014,NM_001287013 GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7022784 9 36147128 [T/C] NR_104639,NM_001287010,NR_104638,NM_001287011,NR_104640,NR_104641,NM_001287012,NR_104637,NM_022343,NM_001287014,NM_001287013 GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16932994 9 36147871 [T/C] NR_104639,NM_001287010,NR_104638,NM_001287011,NR_104640,NR_104641,NM_001287012,NR_104637,NM_022343,NM_001287014,NM_001287013 GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2 EXON Silent,Synonymous_N34N,Silent,Synonymous_N34N,Silent,Silent,Synonymous_N34N,Silent,Synonymous_N34N,Silent,Synonymous_N49N rs10814339 9 36154678 [A/C] NR_104639,NM_001287010,NR_104638,NM_001287011,NR_104640,NR_104641,NM_001287012,NR_104637,NM_022343,NM_001287014,NM_001287013 GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10972763 9 36159456 [T/C] NR_104639,NM_001287010,NR_104638,NM_001287011,NR_104640,NR_104641,NM_001287012,NR_104637,NM_022343,NM_001287014,NM_001287013 GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17778964 9 36160040 [A/G] NR_104639,NM_001287010,NR_104638,NM_001287011,NR_104640,NR_104641,NM_001287012,NR_104637,NM_022343,NM_001287014,NM_001287013 GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2,GLIPR2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7038327 9 36168940 [A/G] rs10972770 9 36169187 [A/C] rs3739610 9 36169494 [A/G] NM_005893 CCIN EXON Silent rs3739609 9 36169598 [T/C] NM_005893 CCIN EXON Synonymous_S33S rs12237915 9 36173934 [T/C] rs10972784 9 36186264 [T/C] rs1999005 9 36190198 [T/G] rs2274523 9 36191004 [T/C] NR_132349,NM_007096,NM_001184762,NM_001311206,NM_001311205,NM_001311204,NM_001184761,NM_001311203,NM_001833,NM_001184760,NM_001076677 CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13287406 9 36200678 [T/C] NR_132349,NM_007096,NM_001184762,NM_001311206,NM_001311205,NM_001311204,NM_001184761,NM_001311203,NM_001833,NM_001184760,NM_001076677 CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4879960 9 36203718 [T/C] NR_132349,NM_007096,NM_001184762,NM_001311206,NM_001311205,NM_001311204,NM_001184761,NM_001311203,NM_001833,NM_001184760,NM_001076677 CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2025879 9 36204455 [T/C] NR_132349,NM_007096,NM_001184762,NM_001311206,NM_001311205,NM_001311204,NM_001184761,NM_001311203,NM_001833,NM_001184760,NM_001076677 CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16933076 9 36207967 [T/C] NR_132349,NM_007096,NM_001184762,NM_001311206,NM_001311205,NM_001311204,NM_001184761,NM_001311203,NM_001833,NM_001184760,NM_001076677 CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1053414 9 36211827 [T/C] NR_132349,NM_007096,NM_001184762,NM_001311206,NM_001311205,NM_001311204,NM_001184761,NM_001311203,NM_001833,NM_001184760,NM_001076677 CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA,CLTA EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1043313 9 36214971 [A/G] NM_001190384,NM_001190388,NM_001190383,NM_001128227,NM_005476 GNE,GNE,GNE,GNE,GNE EXON Silent,Silent,Silent,Silent,Silent rs623166 9 36220436 [A/G] NM_001190384,NM_001190388,NM_001190383,NM_001128227,NM_005476 GNE,GNE,GNE,GNE,GNE Silent,Silent,Silent,Silent,Silent rs10758350 9 36223654 [A/G] NM_001190384,NM_001190388,NM_001190383,NM_001128227,NM_005476 GNE,GNE,GNE,GNE,GNE Silent,Silent,Silent,Silent,Silent rs4879961 9 36231483 [T/C] NM_001190384,NM_001190388,NM_001190383,NM_001128227,NM_005476 GNE,GNE,GNE,GNE,GNE Silent,Silent,Silent,Silent,Silent rs10738958 9 36232413 [T/C] NM_001190384,NM_001190388,NM_001190383,NM_001128227,NM_005476 GNE,GNE,GNE,GNE,GNE Silent,Silent,Silent,Silent,Silent rs7019324 9 36234439 [T/G] NM_001190384,NM_001190388,NM_001190383,NM_001128227,NM_005476 GNE,GNE,GNE,GNE,GNE Silent,Silent,Silent,Silent,Silent rs7871216 9 36245759 [A/G] NM_001190384,NM_001190388,NM_001190383,NM_001128227,NM_005476 GNE,GNE,GNE,GNE,GNE Silent,Silent,Silent,Silent,Silent rs7047950 9 36246044 [A/G] NM_001190384,NM_001190388,NM_001190383,NM_001128227,NM_005476 GNE,GNE,GNE,GNE,GNE EXON Synonymous_I141I,Synonymous_I195I,Synonymous_I200I,Synonymous_I231I,Synonymous_I200I rs4878646 9 36248825 [A/G] NM_001190384,NM_001190388,NM_001190383,NM_001128227,NM_005476 GNE,GNE,GNE,GNE,GNE Silent,Silent,Silent,Silent,Silent rs10758352 9 36250665 [T/C] NM_001190384,NM_001190388,NM_001190383,NM_001128227,NM_005476 GNE,GNE,GNE,GNE,GNE Silent,Silent,Silent,Silent,Silent rs10814362 9 36257992 [T/G] NM_001190384,NM_001190388,NM_001190383,NM_001128227,NM_005476 GNE,GNE,GNE,GNE,GNE Silent,Silent,Silent,Silent,Silent rs7036270 9 36261111 [A/G] NM_001190388,NM_001128227 GNE,GNE Silent,Silent rs10972815 9 36264542 [A/C] NM_001190388,NM_001128227 GNE,GNE Silent,Silent rs12379203 9 36276024 [A/G] NM_001190388,NM_001128227 GNE,GNE Silent,Silent rs4879980 9 36291214 [T/C] rs4879983 9 36295756 [A/C] rs7043864 9 36296476 [T/C] rs10814373 9 36306809 [A/C] rs10123040 9 36307043 [T/C] rs10972843 9 36310642 [T/C] rs7038460 9 36314530 [T/C] rs7043543 9 36315900 [A/G] rs12379853 9 36318240 [T/C] rs12685361 9 36321726 [A/G] rs10972856 9 36322621 [T/C] rs7045875 9 36328849 [T/C] rs10972860 9 36331532 [T/C] rs7034595 9 36338022 [A/G] NM_022781,NM_194329,NM_194328,NM_194332,NM_194330 RNF38,RNF38,RNF38,RNF38,RNF38 EXON Silent,Silent,Silent,Silent,Silent rs7863199 9 36338955 [T/C] NM_022781,NM_194329,NM_194328,NM_194332,NM_194330 RNF38,RNF38,RNF38,RNF38,RNF38 EXON Silent,Silent,Silent,Silent,Silent rs10814376 9 36343164 [T/C] NM_022781,NM_194329,NM_194328,NM_194332,NM_194330 RNF38,RNF38,RNF38,RNF38,RNF38 Silent,Silent,Silent,Silent,Silent rs12347593 9 36346527 [T/C] NM_022781,NM_194329,NM_194328,NM_194332,NM_194330 RNF38,RNF38,RNF38,RNF38,RNF38 Silent,Silent,Silent,Silent,Silent rs10758371 9 36349660 [A/G] NM_022781,NM_194329,NM_194328,NM_194332,NM_194330 RNF38,RNF38,RNF38,RNF38,RNF38 Silent,Silent,Silent,Silent,Silent rs7854992 9 36350665 [T/C] NM_022781,NM_194329,NM_194328,NM_194332,NM_194330 RNF38,RNF38,RNF38,RNF38,RNF38 Silent,Silent,Silent,Silent,Silent rs10814377 9 36351800 [T/C] NM_022781,NM_194329,NM_194328,NM_194332,NM_194330 RNF38,RNF38,RNF38,RNF38,RNF38 Silent,Silent,Silent,Silent,Silent rs12376663 9 36359376 [A/G] NM_022781,NM_194329,NM_194328,NM_194332,NM_194330 RNF38,RNF38,RNF38,RNF38,RNF38 Silent,Silent,Silent,Silent,Silent rs7039144 9 36362002 [T/C] NM_022781,NM_194329,NM_194328,NM_194332,NM_194330 RNF38,RNF38,RNF38,RNF38,RNF38 Silent,Silent,Silent,Silent,Silent rs10972872 9 36367338 [A/G] NM_022781,NM_194329,NM_194328,NM_194332,NM_194330 RNF38,RNF38,RNF38,RNF38,RNF38 Silent,Silent,Silent,Silent,Silent rs12376699 9 36382790 [A/G] NM_022781,NM_194329,NM_194328,NM_194332,NM_194330 RNF38,RNF38,RNF38,RNF38,RNF38 Silent,Silent,Silent,Silent,Silent rs16933266 9 36386218 [T/C] NM_022781,NM_194329,NM_194328,NM_194332,NM_194330 RNF38,RNF38,RNF38,RNF38,RNF38 Silent,Silent,Silent,Silent,Silent rs2243808 9 36398245 [A/G] NM_022781,NM_194329,NM_194328,NM_194332,NM_194330 RNF38,RNF38,RNF38,RNF38,RNF38 Silent,Silent,Silent,Silent,Silent rs954779 9 36419529 [A/G] rs10511928 9 36437700 [A/C] rs12553273 9 36456543 [A/G] rs10511929 9 36458793 [T/C] rs10118394 9 36463744 [T/C] rs10814392 9 36481391 [T/C] rs13291966 9 36488261 [A/C] rs389722 9 36490467 [A/G] rs329376 9 36500619 [A/C] rs10814393 9 36503255 [T/C] rs329366 9 36507639 [T/C] rs426361 9 36525772 [A/G] rs7029237 9 36530955 [A/G] rs7863577 9 36539122 [A/C] rs373510 9 36550835 [T/G] rs444543 9 36565438 [T/C] rs13440297 9 36583668 [T/G] NM_001256688,NR_046337,NM_001256685,NM_014791,NM_001256691,NM_001256692,NM_001256689,NM_001256690,NM_001256693,NM_001256687 MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK EXON Nonsense_E35X,Silent,Nonsense_E35X,Nonsense_E35X,Silent,Silent,Silent,Silent,Silent,Nonsense_E35X rs7019260 9 36623287 [T/C] NM_001256688,NR_046337,NM_001256685,NM_014791,NM_001256691,NM_001256692,NM_001256689,NM_001256690,NM_001256693,NM_001256687 MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7039344 9 36633004 [A/C] NM_001256688,NR_046337,NM_001256685,NM_014791,NM_001256691,NM_001256692,NM_001256689,NM_001256690,NM_001256693,NM_001256687 MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2151643 9 36633854 [A/G] NM_001256688,NR_046337,NM_001256685,NM_014791,NM_001256691,NM_001256692,NM_001256689,NM_001256690,NM_001256693,NM_001256687 MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2265346 9 36635409 [T/G] NM_001256688,NR_046337,NM_001256685,NM_014791,NM_001256691,NM_001256692,NM_001256689,NM_001256690,NM_001256693,NM_001256687 MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780350 9 36639442 [A/G] NM_001256688,NR_046337,NM_001256685,NM_014791,NM_001256691,NM_001256692,NM_001256689,NM_001256690,NM_001256693,NM_001256687 MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13298120 9 36640907 [T/C] NM_001256688,NR_046337,NM_001256685,NM_014791,NM_001256691,NM_001256692,NM_001256689,NM_001256690,NM_001256693,NM_001256687 MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2483641 9 36642362 [T/C] NM_001256688,NR_046337,NM_001256685,NM_014791,NM_001256691,NM_001256692,NM_001256689,NM_001256690,NM_001256693,NM_001256687 MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10814422 9 36647786 [A/G] NM_001256688,NR_046337,NM_001256685,NM_014791,NM_001256691,NM_001256692,NM_001256689,NM_001256690,NM_001256693,NM_001256687 MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10973013 9 36655648 [T/C] NM_001256688,NR_046337,NM_001256685,NM_014791,NM_001256691,NM_001256692,NM_001256689,NM_001256690,NM_001256693,NM_001256687 MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11999329 9 36658287 [A/G] NM_001256688,NR_046337,NM_001256685,NM_014791,NM_001256691,NM_001256692,NM_001256689,NM_001256690,NM_001256693,NM_001256687 MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2274473 9 36674842 [T/C] NM_001256688,NR_046337,NM_001256685,NM_014791,NM_001256691,NM_001256692,NM_001256689,NM_001256690,NM_001256693,NM_001256687 MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK,MELK EXON Synonymous_N491N,Silent,Synonymous_N521N,Synonymous_N562N,Synonymous_N482N,Synonymous_N431N,Synonymous_N530N,Synonymous_N491N,Synonymous_N368N,Synonymous_N514N rs10046792 9 36687106 [A/G] rs4504731 9 36691231 [T/C] rs10814430 9 36693098 [A/G] rs10511931 9 36697735 [A/G] rs2094394 9 36702096 [A/G] rs4880002 9 36702485 [A/G] rs16924367 9 36708464 [T/G] rs10117534 9 36709347 [A/G] rs7019018 9 36718171 [T/C] rs10511932 9 36718368 [A/G] rs7863614 9 36718812 [T/C] rs7848373 9 36718844 [A/G] rs12379827 9 36719751 [A/G] rs11792514 9 36722345 [T/G] rs16933492 9 36722854 [T/C] rs11794314 9 36725914 [A/G] rs10973043 9 36727013 [A/G] rs12552072 9 36727388 [T/C] rs1887432 9 36731326 [T/C] rs10738975 9 36732969 [T/C] rs10738976 9 36736811 [T/C] rs7857754 9 36738641 [A/G] rs7873864 9 36740957 [A/G] rs10116484 9 36741027 [T/C] rs752358 9 36744729 [T/G] rs752357 9 36744752 [T/C] rs6476575 9 36748641 [T/C] rs10814443 9 36754763 [A/G] rs1536544 9 36756622 [A/G] rs1887438 9 36757802 [A/G] rs10973061 9 36765045 [A/G] rs10814447 9 36776224 [T/C] rs2148844 9 36778585 [T/C] rs2381583 9 36782013 [T/C] rs10973075 9 36785184 [A/G] rs10973078 9 36788414 [T/C] rs1176839 9 36789967 [T/C] rs727653 9 36790042 [T/C] rs3849922 9 36790902 [T/C] rs10973080 9 36791430 [T/G] rs10973081 9 36791532 [T/C] rs2800247 9 36793445 [T/C] rs7025013 9 36797328 [T/G] rs13292929 9 36798025 [T/C] rs10758401 9 36798742 [A/G] rs10814455 9 36808003 [T/C] rs2851701 9 36809712 [A/G] rs7850874 9 36812517 [T/C] rs1176844 9 36814647 [T/C] rs11791373 9 36815627 [T/C] rs2800256 9 36816714 [T/G] rs2851696 9 36819706 [T/C] rs2851695 9 36820262 [A/G] rs2800266 9 36820604 [T/G] rs7848675 9 36824086 [A/C] rs2800252 9 36830616 [T/G] rs10973101 9 36836758 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780134 9 36839673 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3739437 9 36840446 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4880018 9 36843844 [A/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780136 9 36845973 [A/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7044118 9 36847139 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7465717 9 36848921 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7852051 9 36851358 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17391260 9 36852316 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4510947 9 36854541 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4326462 9 36855486 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10511934 9 36856268 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2005154 9 36856828 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10814462 9 36859519 [A/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10758407 9 36861137 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10973109 9 36861407 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4880020 9 36863670 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16933658 9 36866070 [A/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7850607 9 36872314 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12684931 9 36876541 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4074255 9 36878774 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10973115 9 36879510 [A/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10758411 9 36880930 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2277143 9 36882141 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780138 9 36885406 [T/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780140 9 36885450 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780142 9 36885598 [T/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3824339 9 36885746 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780143 9 36885919 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7045259 9 36886065 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780144 9 36887241 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4581141 9 36887510 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4268201 9 36888148 [T/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9298973 9 36888975 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11999298 9 36894151 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10973120 9 36895382 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1573257 9 36896143 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3758161 9 36901044 [T/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1936637 9 36901161 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3824341 9 36904177 [A/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10973122 9 36904278 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7034991 9 36905150 [A/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10123925 9 36906843 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10973124 9 36909773 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3758163 9 36911573 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7868521 9 36913074 [T/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4880034 9 36913925 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12349215 9 36919993 [A/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12553834 9 36922489 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780151 9 36926028 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7032626 9 36927364 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4878670 9 36932412 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13288123 9 36934760 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3758165 9 36936360 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10973133 9 36939356 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7047533 9 36941292 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780160 9 36942624 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7853360 9 36943396 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16933784 9 36944882 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12345085 9 36946136 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4880042 9 36950301 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10511936 9 36951035 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4407980 9 36952743 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12351115 9 36956031 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11790931 9 36957379 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10973140 9 36957447 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7876045 9 36957633 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10814484 9 36958016 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1888016 9 36958317 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10758418 9 36960765 [T/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7858508 9 36962064 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10973145 9 36968384 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10121384 9 36968880 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10814496 9 36975108 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13292007 9 36977212 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7043127 9 36977798 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780169 9 36979395 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7019007 9 36980920 [T/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7045954 9 36983604 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10814498 9 36985143 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4880048 9 36989054 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7868665 9 36989746 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10125775 9 36993071 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs883966 9 36993868 [A/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3758171 9 36997417 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1329573 9 36998993 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4880050 9 36999024 [T/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3824344 9 37000687 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7020413 9 37002115 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7852624 9 37003075 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6476606 9 37005561 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4880051 9 37007475 [T/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs999511 9 37010668 [T/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs959396 9 37011289 [A/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2381595 9 37017666 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2297106 9 37020388 [T/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2297105 9 37020622 [A/C] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3013739 9 37031876 [A/G] NM_001280548,NM_001280556,NR_103999,NM_001280555,NM_016734,NM_001280553,NM_001280549,NM_001280554,NM_001280552,NM_001280551,NR_104000,NM_001280547,NM_001280550 PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5,PAX5 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2282079 9 37036247 [A/G] rs4880052 9 37036285 [A/G] rs4256662 9 37038258 [T/G] rs4483247 9 37045825 [A/G] rs1411060 9 37046091 [A/C] rs10973177 9 37055109 [A/G] rs10973183 9 37066231 [T/C] rs7854002 9 37070398 [T/C] rs4132811 9 37075859 [A/G] rs7034554 9 37081301 [A/G] NR_036592 EBLN3P Silent rs7848138 9 37097670 [A/C] rs12000191 9 37119528 [A/G] rs12376809 9 37125911 [T/C] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs10973229 9 37139899 [A/G] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs17385566 9 37163530 [T/C] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs13285022 9 37182050 [T/C] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs10814515 9 37193871 [A/G] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs10973250 9 37198176 [T/C] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs7043643 9 37201664 [A/G] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs7861986 9 37206365 [A/G] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs1472169 9 37209396 [T/C] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs6476618 9 37210264 [T/C] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs7848459 9 37213151 [A/G] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs7041839 9 37218231 [A/G] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs2029647 9 37223751 [T/C] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs489657 9 37256393 [T/G] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs13296908 9 37258237 [A/G] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs13296785 9 37258316 [T/C] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs10973274 9 37259118 [T/C] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs10973276 9 37260487 [A/G] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs308495 9 37277603 [T/G] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs308494 9 37277831 [T/C] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs10973289 9 37289932 [A/C] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs10814518 9 37302155 [T/C] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs17409989 9 37320849 [A/G] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs186299 9 37356403 [A/G] NR_110317,NM_032226,NM_001289119,NM_001289120,NM_001289121 ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7,ZCCHC7 Silent,Silent,Silent,Silent,Silent rs997318 9 37364094 [T/C] rs10814520 9 37364675 [A/G] rs308504 9 37370553 [T/C] rs927928 9 37375126 [A/G] rs3780335 9 37376587 [T/C] rs553850 9 37377959 [A/G] rs2768654 9 37378628 [A/G] rs503897 9 37382099 [A/G] rs7871498 9 37384977 [A/G] rs7025491 9 37387177 [T/C] rs7025809 9 37387218 [T/G] rs7026066 9 37387456 [A/G] rs10814529 9 37390630 [A/G] rs765567 9 37390964 [T/C] rs744985 9 37392087 [A/G] rs12555254 9 37393048 [A/C] rs4878685 9 37394542 [T/C] rs471579 9 37395039 [T/G] rs16934059 9 37395138 [A/C] rs7873371 9 37397532 [A/G] rs2768653 9 37399384 [T/C] rs2087358 9 37404949 [A/G] rs7047872 9 37406391 [T/C] rs6476628 9 37411833 [T/G] rs1571231 9 37411834 [A/G] rs6476629 9 37412704 [T/C] rs17411255 9 37413003 [T/C] rs10814535 9 37418935 [T/C] rs7856656 9 37421065 [T/C] rs2768659 9 37426152 [A/G] NM_012203 GRHPR Silent rs309460 9 37429497 [T/C] NM_012203 GRHPR Silent rs309458 9 37429814 [A/G] NM_012203 GRHPR EXON Synonymous_A193A rs309456 9 37431973 [T/C] NM_012203 GRHPR Silent rs309455 9 37432264 [T/C] NM_012203 GRHPR Silent rs309453 9 37433556 [T/C] NM_012203 GRHPR Silent rs7867764 9 37436105 [A/G] NM_012203 GRHPR Silent rs2840246 9 37438526 [T/C] NM_014872 ZBTB5 EXON Silent rs7039333 9 37439351 [T/G] NM_014872 ZBTB5 EXON Silent rs17502738 9 37441650 [T/C] NM_014872 ZBTB5 EXON Missense_D300G rs10973340 9 37444994 [A/G] NM_014872 ZBTB5 Silent rs11789963 9 37448509 [T/C] NM_014872 ZBTB5 Silent rs309444 9 37454874 [A/G] NM_014872 ZBTB5 Silent rs10973346 9 37458143 [T/C] NM_014872 ZBTB5 Silent rs7049017 9 37464909 [T/C] NM_014872 ZBTB5 Silent rs913280 9 37483309 [T/C] rs913279 9 37483388 [T/C] rs4618787 9 37485017 [T/G] rs10973360 9 37486383 [A/G] NM_022490,NM_001282766 POLR1E,POLR1E Silent,Silent rs1571234 9 37486603 [A/G] NM_022490,NM_001282766 POLR1E,POLR1E Silent,Silent rs2296774 9 37487667 [T/C] NM_022490,NM_001282766 POLR1E,POLR1E Silent,Silent rs10758432 9 37488009 [T/C] NM_022490,NM_001282766 POLR1E,POLR1E Silent,Silent rs16934150 9 37488243 [T/C] NM_022490,NM_001282766 POLR1E,POLR1E Silent,Silent rs1887455 9 37488725 [A/C] NM_022490,NM_001282766 POLR1E,POLR1E Silent,Silent rs3758223 9 37489298 [T/C] NM_022490,NM_001282766 POLR1E,POLR1E Silent,Silent rs10973368 9 37492656 [A/G] NM_022490,NM_001282766 POLR1E,POLR1E EXON Missense_V116I,Missense_V46I rs3739576 9 37492679 [T/G] NM_022490,NM_001282766 POLR1E,POLR1E EXON Synonymous_A123A,Synonymous_A53A rs3739575 9 37492721 [A/G] NM_022490,NM_001282766 POLR1E,POLR1E Silent,Silent rs754950 9 37493114 [A/G] NM_022490,NM_001282766 POLR1E,POLR1E Silent,Silent rs10814567 9 37493548 [A/G] NM_022490,NM_001282766 POLR1E,POLR1E Silent,Silent rs10758434 9 37493588 [T/C] NM_022490,NM_001282766 POLR1E,POLR1E EXON Synonymous_T145T,Synonymous_T75T rs16934203 9 37495899 [T/C] NM_022490,NM_001282766 POLR1E,POLR1E EXON Missense_A223V,Missense_A153V rs2277161 9 37500895 [T/C] NM_022490,NM_001282766 POLR1E,POLR1E EXON Synonymous_T315T,Synonymous_T245T rs17412622 9 37501752 [T/C] NM_022490,NM_001282766 POLR1E,POLR1E EXON Synonymous_T337T,Synonymous_T267T rs7867180 9 37501807 [A/G] NM_022490,NM_001282766 POLR1E,POLR1E EXON Missense_V356M,Missense_V286M rs10814571 9 37503087 [A/G] NM_022490,NM_001282766 POLR1E,POLR1E EXON Missense_R383K,Missense_R313K rs11794762 9 37506966 [A/G] rs10114371 9 37508302 [T/C] rs1006763 9 37509875 [T/C] rs12237351 9 37512808 [T/C] NM_012166 FBXO10 Silent rs10973394 9 37522672 [A/G] NM_012166 FBXO10 Silent rs927930 9 37536998 [T/C] NM_012166 FBXO10 Silent rs7044153 9 37537557 [A/G] NM_012166 FBXO10 EXON Synonymous_A323A rs12337272 9 37542954 [A/G] NM_012166 FBXO10 Silent rs10125441 9 37547256 [T/C] NM_012166 FBXO10 Silent rs13291473 9 37551276 [T/C] NM_012166 FBXO10 Silent rs10973409 9 37552338 [T/G] NM_012166 FBXO10 Silent rs7039920 9 37557720 [T/C] NM_012166 FBXO10 Silent rs10118277 9 37558780 [A/C] NM_012166 FBXO10 Silent rs10814578 9 37565522 [T/C] NM_012166 FBXO10 Silent rs10758440 9 37573330 [A/C] NM_012166 FBXO10 Silent rs9644884 9 37583429 [T/C] rs4621903 9 37587742 [T/C] rs13296887 9 37589346 [A/C] NM_001001790,NM_001134485,NM_001134484 TOMM5,TOMM5,TOMM5 Silent,Silent,Silent rs10758442 9 37591236 [T/G] NM_001001790,NM_001134485,NM_001134484 TOMM5,TOMM5,TOMM5 Silent,Silent,Silent rs7021977 9 37592452 [A/G] NM_001001790,NM_001134485,NM_001134484 TOMM5,TOMM5,TOMM5 EXON Synonymous_S26S,Synonymous_S26S,Synonymous_S26S rs3802416 9 37592607 [A/G] NM_001001790,NM_001134485,NM_001134484 TOMM5,TOMM5,TOMM5 EXON Silent,Silent,Silent rs13283323 9 37611238 [T/C] rs12339112 9 37626975 [T/C] rs10123280 9 37627872 [A/G] rs17505776 9 37629310 [A/C] rs10973443 9 37631583 [A/G] rs999988 9 37635299 [T/C] rs10973446 9 37638744 [A/G] rs9919069 9 37638972 [T/C] rs12344736 9 37641706 [A/C] rs2182318 9 37641833 [T/C] rs875780 9 37647741 [A/G] rs7021824 9 37650203 [T/C] rs7027222 9 37651804 [A/G] NM_014907 FRMPD1 Silent rs12684941 9 37654930 [A/G] NM_014907 FRMPD1 Silent rs1886909 9 37656212 [A/G] NM_014907 FRMPD1 Silent rs10973458 9 37656636 [A/C] NM_014907 FRMPD1 Silent rs6476655 9 37657011 [A/G] NM_014907 FRMPD1 Silent rs1325916 9 37660696 [T/C] NM_014907 FRMPD1 Silent rs6476656 9 37663810 [A/G] NM_014907 FRMPD1 Silent rs10973475 9 37666361 [T/C] NM_014907 FRMPD1 Silent rs10814594 9 37666667 [T/C] NM_014907 FRMPD1 Silent rs16934357 9 37676472 [T/C] NM_014907 FRMPD1 Silent rs13302352 9 37683465 [T/C] NM_014907 FRMPD1 Silent rs7469365 9 37684753 [A/G] NM_014907 FRMPD1 Silent rs13298495 9 37686417 [A/G] NM_014907 FRMPD1 Silent rs10814601 9 37689623 [T/C] NM_014907 FRMPD1 Silent rs10973491 9 37690945 [T/G] NM_014907 FRMPD1 Silent rs3747539 9 37692654 [A/C] NM_014907 FRMPD1 EXON Missense_T6P rs3747540 9 37692733 [T/C] NM_014907 FRMPD1 EXON Missense_S32L rs7028875 9 37694070 [A/G] NM_014907 FRMPD1 Silent rs10511942 9 37702874 [T/C] NM_014907 FRMPD1 Silent rs6476659 9 37707274 [T/G] NM_014907 FRMPD1 Silent rs2296556 9 37707441 [A/G] NM_014907 FRMPD1 EXON Missense_A44T rs6476660 9 37708840 [T/C] NM_014907 FRMPD1 Silent rs2296553 9 37711594 [A/C] NM_014907 FRMPD1 Silent rs7039767 9 37712391 [T/C] NM_014907 FRMPD1 Silent rs1952125 9 37715724 [T/G] NM_014907 FRMPD1 Silent rs10738986 9 37719473 [A/G] NM_014907 FRMPD1 Silent rs4878173 9 37723330 [A/G] NM_014907 FRMPD1 Silent rs10814609 9 37724195 [A/G] NM_014907 FRMPD1 Silent rs2274324 9 37731007 [T/C] NM_014907 FRMPD1 EXON Synonymous_D255D rs2026546 9 37733013 [T/G] NM_014907 FRMPD1 Silent rs750693 9 37733925 [T/C] NM_014907 FRMPD1 Silent rs10758456 9 37739932 [A/G] NM_014907 FRMPD1 Silent rs2281872 9 37740637 [T/C] NM_014907 FRMPD1 EXON Synonymous_A704A rs3747541 9 37745413 [A/G] NM_014907 FRMPD1 EXON Synonymous_E1128E rs10973517 9 37747985 [A/G] rs10511944 9 37749213 [A/G] rs10973520 9 37751219 [T/C] rs7873428 9 37752907 [T/C] rs7873440 9 37752947 [T/C] rs7861041 9 37753058 [A/G] rs10973524 9 37755620 [T/C] NM_001286954,NM_001286951,NM_001286950,NM_144964,NM_001286953,NM_001286952,NR_104612 TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1409145 9 37761044 [T/C] NM_001286954,NM_001286951,NM_001286950,NM_144964,NM_001286953,NM_001286952,NR_104612 TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10115653 9 37768742 [A/G] NM_001286954,NM_001286951,NM_001286950,NM_144964,NM_001286953,NM_001286952,NR_104612 TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7035295 9 37771325 [A/C] NM_001286954,NM_001286951,NM_001286950,NM_144964,NM_001286953,NM_001286952,NR_104612 TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10973537 9 37774893 [A/G] NM_001286954,NM_001286951,NM_001286950,NM_144964,NM_001286953,NM_001286952,NR_104612 TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4878174 9 37775467 [T/C] NM_001286954,NM_001286951,NM_001286950,NM_144964,NM_001286953,NM_001286952,NR_104612 TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12337034 9 37776283 [T/C] NM_001286954,NM_001286951,NM_001286950,NM_144964,NM_001286953,NM_001286952,NR_104612 TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B,TRMT10B EXON Missense_V131A,Missense_V147A,Missense_V191A,Missense_V242A,Missense_V131A,Missense_V164A,Silent rs1059059 9 37780558 [A/C] NM_001002269,NM_016042 EXOSC3,EXOSC3 EXON Silent,Silent rs3208406 9 37780831 [A/G] NM_001002269,NM_016042 EXOSC3,EXOSC3 EXON Silent,Missense_Y225H rs10814620 9 37788911 [T/C] rs927631 9 37796342 [A/G] rs10120822 9 37797412 [T/C] rs872778 9 37806245 [T/C] NM_001286810,NM_024345 DCAF10,DCAF10 Silent,Silent rs2841954 9 37814873 [T/C] NM_001286810,NM_024345 DCAF10,DCAF10 Silent,Silent rs2841946 9 37820416 [A/G] NM_001286810,NM_024345 DCAF10,DCAF10 Silent,Silent rs10973569 9 37824303 [A/G] NM_001286810,NM_024345 DCAF10,DCAF10 Silent,Silent rs10118319 9 37829600 [T/C] NM_001286810,NM_024345 DCAF10,DCAF10 Silent,Silent rs10115457 9 37861794 [A/C] NM_001286810,NM_024345 DCAF10,DCAF10 EXON Silent,Silent rs7859075 9 37865943 [A/G] NM_001286810,NM_024345 DCAF10,DCAF10 EXON Silent,Silent rs10511954 9 37866551 [T/C] NM_001286810,NM_024345 DCAF10,DCAF10 EXON Silent,Silent rs7873455 9 37874090 [T/C] rs13294843 9 37886429 [A/G] NR_024872,NR_024873 SLC25A51,SLC25A51 Silent,Silent rs2025440 9 37889241 [T/C] NR_024872,NR_024873,NM_033412 SLC25A51,SLC25A51,SLC25A51 Silent,Silent,Silent rs2025439 9 37889858 [T/C] NR_024872,NR_024873,NM_033412 SLC25A51,SLC25A51,SLC25A51 Silent,Silent,Silent rs10973607 9 37911531 [T/C] rs3747547 9 37916408 [T/C] NM_003028 SHB EXON Silent rs2281784 9 37919743 [T/C] NM_003028 SHB EXON Silent rs1082865 9 37932314 [T/C] NM_003028 SHB Silent rs776023 9 37934140 [T/C] NM_003028 SHB Silent rs776022 9 37934780 [T/C] NM_003028 SHB Silent rs12005004 9 37937639 [T/C] NM_003028 SHB Silent rs776019 9 37939673 [T/G] NM_003028 SHB Silent rs776015 9 37942152 [A/C] NM_003028 SHB Silent rs7027014 9 37943571 [T/C] NM_003028 SHB Silent rs735740 9 37944427 [A/G] NM_003028 SHB Silent rs7864512 9 37949638 [A/G] NM_003028 SHB Silent rs2103241 9 37950936 [T/C] NM_003028 SHB Silent rs2091415 9 37951176 [T/C] NM_003028 SHB Silent rs16934664 9 37952192 [A/G] NM_003028 SHB Silent rs7044060 9 37956271 [A/G] NM_003028 SHB Silent rs3802414 9 37974481 [T/G] NM_003028 SHB Silent rs1138374 9 37974743 [T/C] NM_003028 SHB EXON Synonymous_S310S rs2149547 9 37990801 [A/G] NM_003028 SHB Silent rs11789441 9 37993303 [T/G] NM_003028 SHB Silent rs10973634 9 37995845 [T/C] NM_003028 SHB Silent rs10973635 9 37996724 [T/G] NM_003028 SHB Silent rs12345885 9 38003567 [T/C] NM_003028 SHB Silent rs4878737 9 38020544 [T/G] NM_003028 SHB Silent rs16934720 9 38022195 [A/G] NM_003028 SHB Silent rs7856790 9 38023500 [A/G] NM_003028 SHB Silent rs943936 9 38027644 [T/C] NM_003028 SHB Silent rs7025303 9 38040095 [T/C] NM_003028 SHB Silent rs4878743 9 38058424 [T/C] NM_003028 SHB Silent rs12351815 9 38062427 [T/C] NM_003028 SHB Silent rs1928251 9 38074715 [T/C] rs4262388 9 38081261 [T/C] rs7037490 9 38085784 [A/G] rs1928233 9 38089638 [A/G] rs7024427 9 38089969 [T/C] rs7021766 9 38090793 [T/C] rs4878750 9 38098363 [T/C] rs12552637 9 38114557 [T/C] rs11791344 9 38125272 [T/C] rs4878753 9 38128597 [A/G] rs7039254 9 38129670 [T/G] rs885431 9 38135564 [A/G] rs943934 9 38138880 [T/C] rs4878754 9 38138947 [A/C] rs10973681 9 38140772 [A/G] rs10814661 9 38141369 [A/G] rs1928242 9 38144829 [T/C] rs943935 9 38150167 [T/G] rs10973683 9 38151268 [A/C] rs7859035 9 38154137 [A/G] rs12004825 9 38159475 [A/G] rs12344175 9 38160747 [A/G] rs10441687 9 38164364 [T/C] rs2165776 9 38165646 [A/G] rs10758476 9 38168321 [A/G] rs12235873 9 38176640 [A/G] rs4242645 9 38178570 [T/C] rs10758477 9 38179054 [A/G] rs4878759 9 38182929 [T/C] rs4878761 9 38186096 [T/C] rs10973694 9 38187008 [A/G] rs12003607 9 38187416 [T/C] rs894520 9 38189527 [T/C] rs4878763 9 38190816 [A/G] rs4878764 9 38191117 [A/G] rs10118655 9 38196563 [A/G] rs12352894 9 38197384 [T/C] rs10973703 9 38198629 [T/C] rs2810747 9 38199821 [A/G] rs2053553 9 38205001 [A/G] rs12003798 9 38205577 [A/G] rs920706 9 38207733 [T/C] rs10118416 9 38208693 [A/G] rs2810729 9 38209247 [T/C] rs920707 9 38210621 [T/C] rs2810726 9 38214047 [T/C] rs13300331 9 38225264 [T/C] rs4878187 9 38227021 [T/C] rs4271056 9 38232043 [T/C] rs894525 9 38233891 [A/C] rs1006087 9 38235659 [A/G] rs2810723 9 38244221 [T/C] rs2585692 9 38250950 [A/G] rs10511947 9 38251684 [A/G] rs4388534 9 38252526 [T/C] rs7045845 9 38254018 [T/G] rs2810762 9 38257360 [T/C] rs10973716 9 38258023 [T/C] rs2810760 9 38260952 [T/C] rs1923425 9 38272467 [A/C] rs570941 9 38273626 [T/G] rs4878190 9 38278291 [A/G] rs189315 9 38280691 [T/C] rs17443417 9 38282317 [A/G] rs4878777 9 38282692 [T/G] rs12238450 9 38284646 [A/G] rs341485 9 38285290 [T/C] rs12551041 9 38286537 [A/C] rs10973730 9 38289065 [A/C] rs1348335 9 38290172 [T/C] rs4878191 9 38290694 [A/C] rs189312 9 38292733 [T/C] rs10973731 9 38293885 [A/C] rs10758485 9 38296262 [A/G] rs10973734 9 38296609 [A/G] rs2840227 9 38297774 [A/G] rs726363 9 38298233 [A/G] rs763935 9 38298279 [T/C] rs1442977 9 38299419 [A/C] rs7023239 9 38300657 [T/G] rs4878782 9 38303243 [T/C] rs1885490 9 38309332 [A/G] rs1885492 9 38309523 [T/C] rs560512 9 38312365 [A/G] rs4878783 9 38316331 [A/C] rs341466 9 38318134 [A/C] rs4878784 9 38328183 [A/G] rs16935064 9 38330114 [A/G] rs11792523 9 38333064 [A/G] rs10973753 9 38335032 [T/C] rs1885493 9 38335475 [A/G] rs1555481 9 38337291 [T/G] rs10732359 9 38342744 [T/C] rs7866655 9 38344729 [T/C] rs10814680 9 38355452 [A/G] rs17444315 9 38355790 [T/C] rs4878790 9 38357065 [A/G] rs1923431 9 38360333 [T/C] rs10973759 9 38360890 [A/G] rs4878791 9 38361379 [T/C] rs1004604 9 38362171 [T/C] rs1033794 9 38365696 [T/G] rs911755 9 38371434 [T/C] rs6476690 9 38372888 [A/C] rs4878795 9 38376173 [T/G] rs4878797 9 38380350 [A/C] rs10973770 9 38380389 [A/G] rs10973772 9 38381308 [T/G] rs7848268 9 38382340 [A/G] rs11790480 9 38384578 [A/G] rs1555480 9 38386351 [T/C] rs10738997 9 38390937 [T/C] rs7040397 9 38392256 [A/G] rs4646769 9 38392938 [T/C] NM_000692 ALDH1B1 Silent rs4646770 9 38393171 [A/G] NM_000692 ALDH1B1 Silent rs4242647 9 38393209 [T/C] NM_000692 ALDH1B1 Silent rs7846941 9 38394563 [A/G] NM_000692 ALDH1B1 Silent rs4646771 9 38394806 [T/C] NM_000692 ALDH1B1 Silent rs4646772 9 38394961 [T/G] NM_000692 ALDH1B1 Silent rs2073477 9 38395928 [T/C] NM_000692 ALDH1B1 EXON Synonymous_T61T rs2228093 9 38396002 [T/C] NM_000692 ALDH1B1 EXON Missense_A86V rs2073478 9 38396065 [T/G] NM_000692 ALDH1B1 EXON Missense_R107L rs4646773 9 38396350 [T/C] NM_000692 ALDH1B1 EXON Missense_T202I rs3043 9 38397355 [G/C] NM_000692 ALDH1B1 EXON Silent rs7859877 9 38397915 [A/G] NM_000692 ALDH1B1 EXON Silent rs4646774 9 38398826 [A/G] rs7853954 9 38399721 [T/G] rs4878805 9 38404105 [T/C] rs4878807 9 38404260 [T/C] rs7865905 9 38404352 [T/C] rs4878808 9 38404579 [T/C] rs4878809 9 38405834 [A/G] rs11791018 9 38406458 [T/C] rs11361 9 38406590 [A/G] NM_001007563 IGFBPL1 EXON Silent rs1475102 9 38407090 [T/C] NM_001007563 IGFBPL1 EXON Silent rs7021469 9 38407767 [A/C] NM_001007563 IGFBPL1 EXON Silent rs1923424 9 38407860 [A/C] NM_001007563 IGFBPL1 EXON Silent rs4878811 9 38408525 [A/C] NM_001007563 IGFBPL1 EXON Silent rs2038589 9 38408592 [T/C] NM_001007563 IGFBPL1 EXON Silent rs7857243 9 38409081 [A/G] NM_001007563 IGFBPL1 EXON Silent rs7029786 9 38409232 [A/G] NM_001007563 IGFBPL1 Silent rs4086036 9 38417990 [A/G] NM_001007563 IGFBPL1 Silent rs1467574 9 38421975 [A/G] NM_001007563 IGFBPL1 Silent rs2381871 9 38426961 [T/C] rs12684944 9 38427185 [T/C] rs998226 9 38427593 [A/G] rs7046458 9 38430109 [T/C] rs10973813 9 38431667 [A/G] rs1022772 9 38435825 [T/G] rs10973819 9 38436525 [A/G] rs769153 9 38436992 [T/G] rs4298574 9 38440543 [T/C] rs4480202 9 38440859 [T/C] rs12551371 9 38445742 [A/G] rs4424353 9 38450984 [T/C] rs1110183 9 38456365 [A/G] rs4394481 9 38456840 [A/G] rs10973834 9 38457824 [T/C] rs2799731 9 38466944 [A/C] rs1891920 9 38468570 [T/G] rs2996504 9 38474204 [T/C] rs10814700 9 38478011 [T/G] rs2799740 9 38478777 [T/C] rs10973853 9 38483399 [T/G] rs10115535 9 38502355 [T/C] rs2996368 9 38522055 [A/C] rs2993164 9 38522203 [A/G] rs7871044 9 38528689 [A/G] rs2993156 9 38531889 [T/C] rs10973874 9 38533004 [T/C] rs7855657 9 38533468 [T/C] rs10973883 9 38541855 [A/G] NR_047651 FAM95C Silent rs2993129 9 38563171 [T/C] rs10814720 9 38572216 [T/C] NM_147195,NM_001331100 ANKRD18A,ANKRD18A Silent,Silent rs2381858 9 38615175 [A/C] NM_147195,NM_001331100 ANKRD18A,ANKRD18A Silent,Silent rs10973939 9 38626309 [T/C] rs10973948 9 38633652 [A/G] rs10973951 9 38636463 [A/G] rs12340088 9 38639318 [T/G] rs10973953 9 38639853 [A/G] rs945844 9 38641335 [A/G] rs12708274 9 38641599 [A/G] rs883954 9 38642154 [A/G] rs11790597 9 38646995 [T/C] rs1890112 9 38648775 [A/C] rs10758511 9 38650244 [T/C] rs10758513 9 38652915 [T/C] rs11792859 9 38652961 [A/G] rs16931666 9 38654225 [T/C] rs3005838 9 38654385 [T/C] rs16931661 9 38654738 [T/C] rs9407070 9 38654814 [A/G] rs6476727 9 38655153 [A/G] rs1577869 9 38655269 [T/C] rs1577868 9 38655438 [T/G] rs9298981 9 38655835 [T/C] rs3124041 9 38657104 [A/G] rs17456345 9 38657144 [T/C] rs3124044 9 38660694 [A/G] rs7031991 9 38661416 [A/G] rs7850704 9 38666106 [T/C] rs12337426 9 38667363 [T/C] rs12555495 9 38668070 [A/G] rs12352401 9 38668792 [A/G] rs2993177 9 38669062 [A/G] rs7048582 9 38670778 [T/C] rs7850196 9 38671574 [T/G] rs4074217 9 38671889 [A/G] rs13294686 9 38673236 [A/G] rs12686391 9 38673327 [T/C] rs7873962 9 38673606 [T/G] rs16931494 9 38673912 [A/C] rs12006317 9 38674186 [A/G] rs13285740 9 38675083 [A/C] rs7039377 9 38675465 [A/G] rs10973967 9 38677071 [A/G] rs10814734 9 38677136 [A/C] rs10973968 9 38677513 [A/C] rs7875312 9 38677737 [A/G] rs7849958 9 38678740 [A/C] rs4641154 9 38679722 [A/G] rs4242651 9 38680826 [T/C] rs4878845 9 38683660 [A/C] rs13292644 9 38685261 [T/C] rs4593645 9 38685643 [A/C] rs10739004 9 38687510 [T/C] rs4878219 9 38693047 [T/C] rs10973981 9 38699239 [T/C] rs10511950 9 38699876 [T/C] rs10758517 9 38700361 [A/G] rs12353084 9 38704570 [A/C] rs4557782 9 38704680 [T/C] rs10511952 9 38705208 [A/G] rs16935357 9 38708759 [T/C] rs10973988 9 38709952 [A/G] rs10116668 9 38711068 [A/C] rs12686281 9 38713081 [T/C] rs4129107 9 38714729 [T/C] rs10511953 9 38715865 [T/C] rs7848575 9 38718308 [T/G] rs4878849 9 38719533 [T/C] rs17536503 9 38720168 [A/G] rs12682690 9 38720627 [T/C] rs10758522 9 38733080 [T/C] rs10814752 9 38736897 [T/C] rs10974006 9 38738294 [T/G] rs10974007 9 38738620 [T/C] rs7873278 9 38740012 [A/C] rs7864522 9 38741712 [T/C] rs7025213 9 38742787 [A/C] rs11788708 9 38743702 [T/G] rs9407079 9 38743727 [T/C] rs11788266 9 38746404 [A/G] rs7470425 9 38747064 [T/C] rs7469548 9 38751317 [T/C] rs10758523 9 38752068 [T/C] rs10814755 9 38753508 [A/G] rs10974023 9 38753875 [A/G] rs7468058 9 38756606 [A/G] rs10116618 9 38769003 [T/C] rs10758527 9 38770134 [A/G] rs10814762 9 38771460 [A/G] rs7037234 9 38771831 [T/G] rs7853023 9 38772575 [A/G] rs10974037 9 38773251 [A/G] rs6476761 9 39004140 [T/C] rs428437 9 39076028 [A/G] NM_033655 CNTNAP3 Silent rs7852039 9 39103743 [T/C] NM_033655 CNTNAP3 EXON Missense_R845H rs10974171 9 39141699 [A/C] NM_033655 CNTNAP3 Silent rs10974177 9 39170879 [T/C] NM_033655 CNTNAP3 Silent rs10122337 9 39179289 [T/C] NM_033655 CNTNAP3 Silent rs4409505 9 39249923 [A/G] NM_033655 CNTNAP3 Silent rs7470874 9 39267386 [T/C] NM_033655 CNTNAP3 Silent rs28448571 9 40507792 [T/C] rs2476831 9 40714011 [A/G] rs1360542 9 40776064 [T/C] NR_134255,NM_033160,NM_001317916 ZNF658,ZNF658,ZNF658 Silent,Silent,Silent rs7022725 9 40782561 [T/C] NR_134255,NM_033160,NM_001317916 ZNF658,ZNF658,ZNF658 Silent,Silent,Silent rs4339692 9 40784448 [A/G] NR_134255,NM_033160,NM_001317916 ZNF658,ZNF658,ZNF658 Silent,Silent,Silent rs28762375 9 40800551 [T/C] rs3124913 9 41290880 [T/C] rs2721390 9 41451854 [T/G] rs12376355 9 41867190 [A/G] rs28814072 9 41981757 [A/G] NR_003670 FGF7P3 Silent rs7022910 9 42112677 [T/C] rs12342998 9 42153919 [T/C] rs9413149 9 42173523 [A/C] rs11262566 9 42231938 [A/G] rs7861819 9 42253033 [T/C] rs28719003 9 42337663 [A/G] rs10123921 9 43127335 [T/C] NM_001012419,NM_001012421 ANKRD20A3,ANKRD20A2 Silent,Silent rs28552539 9 43314125 [A/C] rs10441809 9 43581253 [A/C] rs4031759 9 44057312 [T/C] rs28683530 9 44218056 [A/C] rs10909782 9 44401981 [T/C] NR_126050 LOC103908605 EXON Silent rs28728452 9 44779633 [T/C] rs11263321 9 44863631 [A/G] rs10121167 9 44865026 [T/G] rs6606438 9 44866028 [T/C] rs10752557 9 44881336 [A/C] rs10114349 9 44887313 [A/G] rs4126931 9 46279935 [T/C] rs1621732 9 46386250 [A/G] NR_103714 FAM27E2 EXON Silent rs10217124 9 46936811 [A/G] rs12555033 9 46944322 [A/G] rs4599924 9 47020969 [T/G] rs7855071 9 65629772 [A/G] rs2507413 9 66288522 [A/G] rs11793784 9 66456196 [A/G] rs9330057 9 67051352 [A/C] rs2506447 9 67066659 [T/C] rs10797110 9 67273324 [T/C] NR_002817 AQP7P1 Silent rs1756227 9 67693021 [T/C] rs637218 9 67747964 [A/G] rs3126276 9 67769435 [T/C] rs3126277 9 67769541 [T/C] rs3126280 9 67783601 [A/G] rs4123092 9 67836968 [T/C] rs28702009 9 67965636 [T/G] NM_032250,NM_001012419 ANKRD20A1,ANKRD20A3 Silent,Silent rs28451650 9 67965668 [A/C] NM_032250,NM_001012419 ANKRD20A1,ANKRD20A3 Silent,Silent rs28437453 9 67966514 [T/C] NM_032250,NM_001012419 ANKRD20A1,ANKRD20A3 Silent,Silent rs10908023 9 68167130 [T/C] rs11262889 9 68299120 [A/C] rs4342723 9 68373702 [T/C] rs34953946 9 68434298 [A/C] NR_033907 FRG1JP Silent rs35284732 9 68440324 [A/G] NR_033907 FRG1JP Silent rs4275319 9 68513625 [A/G] rs2810204 9 69108060 [A/G] NR_156730,NR_002836 FRG1HP,PGM5P2 Silent,Silent rs4634774 9 69194231 [A/G] NR_147036 LOC440896 Silent rs1876779 9 69355037 [A/G] rs1858130 9 69410435 [A/C] NR_146419,NM_001098805 ANKRD20A4-ANKRD20A20P,ANKRD20A4 Silent,Silent rs12351779 9 69546317 [T/G] rs2265945 9 70126786 [T/G] rs4538982 9 70580311 [T/C] rs2251501 9 70913399 [T/C] NM_201453,NM_001291821 CBWD3,CBWD3 Silent,Silent rs12376223 9 70922571 [A/G] rs449851 9 70984372 [A/G] NM_021965 PGM5 Silent rs11141466 9 71019573 [T/C] NM_021965 PGM5 Silent rs7033627 9 71033538 [T/C] NM_021965 PGM5 Silent rs7852479 9 71034203 [T/C] NM_021965 PGM5 Silent rs10868795 9 71040170 [A/C] NM_021965 PGM5 Silent rs7020465 9 71041878 [A/G] NM_021965 PGM5 Silent rs10735596 9 71044126 [T/C] NM_021965 PGM5 Silent rs1158127 9 71058191 [A/G] NM_021965 PGM5 Silent rs10868856 9 71071933 [A/G] NM_021965 PGM5 Silent rs10868877 9 71082682 [T/C] NM_021965 PGM5 Silent rs10868879 9 71083458 [A/G] NM_021965 PGM5 Silent rs7039149 9 71093854 [A/G] NM_021965 PGM5 Silent rs10868913 9 71098987 [A/G] NM_021965 PGM5 Silent rs10868922 9 71100140 [A/C] NM_021965 PGM5 Silent rs7022220 9 71106512 [T/C] NM_021965 PGM5 Silent rs424970 9 71113835 [T/C] NM_021965 PGM5 Silent rs12685375 9 71114312 [T/C] NM_021965 PGM5 Silent rs7039076 9 71115991 [T/C] NM_021965 PGM5 Silent rs928049 9 71120013 [T/C] NM_021965 PGM5 Silent rs10780986 9 71123747 [A/G] NM_021965 PGM5 Silent rs2131355 9 71128144 [T/C] NM_021965 PGM5 Silent rs11142714 9 71131098 [T/C] NM_021965 PGM5 Silent rs10780999 9 71137232 [T/C] NM_021965 PGM5 Silent rs10781002 9 71138802 [A/G] NM_021965 PGM5 Silent rs265077 9 71146533 [A/G] rs265076 9 71151234 [T/G] rs398222 9 71153062 [A/G] NM_153237 TMEM252 Silent rs10120859 9 71156295 [T/C] rs11789244 9 71156380 [A/G] rs10869020 9 71156551 [A/G] rs11142838 9 71160278 [T/C] NR_109769 LINC01506 Silent rs17085775 9 71167878 [T/C] rs3920702 9 71170130 [A/G] rs10869043 9 71171819 [A/C] rs10869048 9 71178178 [A/C] rs4382540 9 71183181 [T/C] rs7046236 9 71184769 [T/C] rs954453 9 71186301 [T/C] rs4143074 9 71189353 [T/C] rs17388292 9 71189502 [A/G] rs10869061 9 71190659 [A/G] rs11143002 9 71192508 [A/G] rs11143005 9 71193270 [T/G] rs2026349 9 71193615 [A/C] rs4745127 9 71196376 [T/C] rs1411996 9 71199545 [T/C] rs7871664 9 71199866 [T/C] rs17052441 9 71210358 [A/G] rs10511959 9 71210894 [A/G] rs2183738 9 71211200 [T/C] rs7032966 9 71211602 [T/C] rs1125350 9 71213397 [A/G] rs1331472 9 71214885 [T/C] rs1411998 9 71215869 [A/C] rs952436 9 71219086 [T/C] rs2026348 9 71219289 [A/G] rs4271029 9 71222430 [A/G] rs4285547 9 71223294 [T/C] rs10869119 9 71224928 [A/C] rs2003195 9 71225132 [T/C] rs7864204 9 71229179 [A/G] rs7851511 9 71233266 [A/G] rs7859798 9 71235229 [A/G] rs944550 9 71241117 [A/C] rs10869160 9 71241343 [A/G] rs17480362 9 71243554 [T/C] rs4744669 9 71244025 [T/C] rs10869163 9 71245156 [A/G] rs10869167 9 71247375 [T/C] rs4347049 9 71250999 [T/C] rs12349475 9 71253821 [T/C] rs4744671 9 71253918 [T/C] rs12004348 9 71260553 [T/C] rs1888723 9 71265112 [A/G] rs7024606 9 71267754 [A/C] rs1556533 9 71273949 [A/G] rs10869192 9 71280103 [A/G] rs7858883 9 71291630 [T/C] rs1014237 9 71301557 [T/G] rs12338099 9 71305001 [T/G] rs10869200 9 71309707 [T/C] rs10735616 9 71313742 [T/C] rs7023009 9 71318128 [T/G] rs1107108 9 71318817 [T/C] rs2151418 9 71324475 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs4534183 9 71325908 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10121993 9 71328378 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10125301 9 71331990 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs4745223 9 71334809 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs4745228 9 71344802 [T/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs4745230 9 71345123 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs11143568 9 71346288 [T/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs4745231 9 71346717 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs17057092 9 71347362 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs13296679 9 71347988 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7044422 9 71352493 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10781142 9 71353056 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10735624 9 71354184 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7044045 9 71355133 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7866673 9 71357605 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10869263 9 71364769 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs4744689 9 71365013 [A/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs11143622 9 71370051 [T/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10735625 9 71370174 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs1336492 9 71376291 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs945573 9 71383888 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7031263 9 71384758 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7035163 9 71386041 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10781151 9 71386755 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10511964 9 71387764 [A/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs4623507 9 71392876 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs12349968 9 71396426 [A/G] NM_001278253,NM_003558,NM_138333 PIP5K1B,PIP5K1B,FAM122A EXON Silent,Silent,Silent rs975123 9 71396746 [A/G] NM_001278253,NM_003558,NM_138333 PIP5K1B,PIP5K1B,FAM122A EXON Silent,Silent,Silent rs1412988 9 71397734 [A/G] NM_001278253,NM_003558,NM_138333 PIP5K1B,PIP5K1B,FAM122A EXON Silent,Silent,Silent rs2017 9 71397747 [T/C] NM_001278253,NM_003558,NM_138333 PIP5K1B,PIP5K1B,FAM122A EXON Silent,Silent,Silent rs12341286 9 71408647 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs2039624 9 71417919 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs17391596 9 71421343 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10511963 9 71421359 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs11143793 9 71425223 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs1556751 9 71433212 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs1889150 9 71443540 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs4376559 9 71444189 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10448338 9 71452275 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs4745321 9 71453443 [A/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7871676 9 71454316 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10869400 9 71457602 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7874714 9 71460428 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10781232 9 71464932 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7041004 9 71470111 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs12339863 9 71471494 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs6560397 9 71471912 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7043727 9 71472782 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7863342 9 71473803 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs11144027 9 71475381 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs945572 9 71480934 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs2152647 9 71482288 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs4744726 9 71484028 [T/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs1414950 9 71497556 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs953036 9 71509599 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs6560420 9 71512668 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs883951 9 71514547 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs883952 9 71514651 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7855908 9 71517082 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7865397 9 71517261 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10781264 9 71519136 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7024695 9 71521810 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs17058884 9 71527774 [T/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10114114 9 71530957 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7859638 9 71533367 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10869538 9 71539731 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7875472 9 71540231 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10781283 9 71546444 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs17406856 9 71549395 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7030009 9 71551140 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs4745402 9 71554159 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10746974 9 71555522 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs3829061 9 71557341 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs12342490 9 71559537 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10123076 9 71559726 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs11144442 9 71562055 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs1576586 9 71567239 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10114872 9 71574757 [A/G] NM_001278253,NM_003558,NR_110647 PIP5K1B,PIP5K1B,LOC101927069 Silent,Silent,Silent rs11144523 9 71575180 [T/C] NM_001278253,NM_003558,NR_110647 PIP5K1B,PIP5K1B,LOC101927069 Silent,Silent,Silent rs10124169 9 71576640 [A/G] NM_001278253,NM_003558,NR_110647 PIP5K1B,PIP5K1B,LOC101927069 Silent,Silent,Silent rs7020192 9 71577792 [T/C] NM_001278253,NM_003558,NR_110647 PIP5K1B,PIP5K1B,LOC101927069 Silent,Silent,Silent rs10781306 9 71591393 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7048825 9 71595965 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs12378665 9 71597840 [T/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7031059 9 71598339 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs2297231 9 71606315 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs883751 9 71612891 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs2871223 9 71615766 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs1888330 9 71617269 [T/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10781329 9 71618245 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs10869686 9 71620614 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs7019661 9 71621276 [A/G] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs1541083 9 71621922 [A/C] NM_001278253,NM_003558 PIP5K1B,PIP5K1B Silent,Silent rs872077 9 71624695 [A/G] rs28461568 9 71626508 [A/T] rs11144762 9 71627283 [T/C] rs12345886 9 71627525 [T/G] NM_002732 PRKACG EXON Silent rs3730386 9 71628207 [C/G] NM_002732 PRKACG EXON Missense_H268D rs10735644 9 71629284 [A/G] rs4745514 9 71629914 [T/C] rs34539730 9 71630576 [T/C] rs4745517 9 71630663 [T/C] rs10869721 9 71630841 [A/G] rs4745520 9 71631733 [A/C] rs10869745 9 71642499 [A/G] rs9314845 9 71643131 [T/C] rs3763608 9 71647375 [T/C] rs3763609 9 71647410 [T/C] rs7046232 9 71648083 [A/G] rs12000125 9 71649464 [T/C] rs1800651 9 71651605 [A/G] NM_000144,NM_181425 FXN,FXN Silent,Silent rs3793451 9 71659280 [T/C] NM_000144,NM_181425 FXN,FXN Silent,Silent rs3829062 9 71668197 [T/C] NM_000144,NM_181425 FXN,FXN Silent,Silent rs2309394 9 71671116 [A/G] NM_000144,NM_181425 FXN,FXN Silent,Silent rs3793455 9 71673030 [T/C] NM_000144,NM_181425 FXN,FXN Silent,Silent rs3793465 9 71679438 [A/G] NM_000144,NM_181425 FXN,FXN Silent,Silent rs9314854 9 71686181 [T/C] NM_000144,NM_181425 FXN,FXN Silent,Silent rs7870295 9 71686476 [A/G] NM_000144,NM_181425 FXN,FXN Silent,Silent rs10890 9 71687924 [T/C] NM_000144,NM_181425 FXN,FXN EXON Silent,Silent rs4744807 9 71688300 [A/G] NM_000144,NM_181425 FXN,FXN EXON Silent,Silent rs4744808 9 71688311 [T/C] NM_000144,NM_181425 FXN,FXN EXON Silent,Silent rs11145043 9 71688476 [T/G] NM_000144,NM_181425 FXN,FXN EXON Silent,Silent rs4745580 9 71689756 [T/C] NM_000144,NM_181425 FXN,FXN EXON Silent,Silent rs6560551 9 71698202 [A/G] rs11145103 9 71698581 [A/C] rs7027499 9 71707902 [A/G] rs7851458 9 71709115 [T/C] rs11790543 9 71712224 [T/C] rs11145193 9 71712736 [T/C] rs11145194 9 71712866 [T/C] rs4744826 9 71719618 [T/C] rs7870657 9 71724126 [A/G] rs11145330 9 71733603 [A/C] rs6560585 9 71747395 [A/G] NM_001170414 TJP2 Silent rs7875573 9 71753270 [A/G] NM_001170414 TJP2 Silent rs17061543 9 71755629 [A/G] NM_001170414 TJP2 Silent rs11145422 9 71755705 [T/C] NM_001170414 TJP2 Silent rs13286409 9 71759542 [T/C] NM_001170414 TJP2 Silent rs10781440 9 71762766 [A/G] NM_001170414 TJP2 Silent rs5006364 9 71765617 [T/C] NM_001170414 TJP2 Silent rs4745646 9 71769323 [T/C] NM_001170414 TJP2 Silent rs1416738 9 71787927 [T/C] NM_001170414 TJP2 Silent rs17061953 9 71791043 [A/G] NM_001170414,NM_201629,NM_004817 TJP2,TJP2,TJP2 Silent,Silent,Silent rs1538583 9 71791547 [A/G] NM_001170414,NM_201629,NM_004817 TJP2,TJP2,TJP2 Silent,Silent,Silent rs3002378 9 71802285 [A/G] NM_001170414,NM_201629,NM_004817 TJP2,TJP2,TJP2 Silent,Silent,Silent rs7043149 9 71813571 [T/C] NM_001170414,NM_201629,NM_004817 TJP2,TJP2,TJP2 Silent,Silent,Silent rs4338173 9 71820740 [T/C] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 Silent,Silent,Silent,Silent,Silent rs11137572 9 71838080 [A/G] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 Silent,Silent,Silent,Silent,Silent rs2486448 9 71838985 [T/G] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 Silent,Silent,Silent,Silent,Silent rs17062682 9 71840396 [A/C] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 Silent,Silent,Silent,Silent,Silent rs17062695 9 71841018 [A/G] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 EXON Synonymous_L356L,Synonymous_L379L,Synonymous_L379L,Synonymous_L383L,Synonymous_L410L rs11137588 9 71842391 [T/C] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 Silent,Silent,Silent,Silent,Silent rs2309428 9 71843023 [A/C] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 EXON Missense_D459E,Missense_D482E,Missense_D482E,Missense_D486E,Missense_D513E rs955792 9 71846783 [T/C] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 Silent,Silent,Silent,Silent,Silent rs10867187 9 71849766 [T/C] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 Silent,Silent,Silent,Silent,Silent rs10746573 9 71850141 [A/C] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 Silent,Silent,Silent,Silent,Silent rs2275431 9 71850853 [A/G] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 Silent,Silent,Silent,Silent,Silent rs2309421 9 71852760 [A/G] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 Silent,Silent,Silent,Silent,Silent rs2498421 9 71855357 [A/G] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 Silent,Silent,Silent,Silent,Silent rs2486456 9 71858517 [T/C] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 Silent,Silent,Silent,Silent,Silent rs3750551 9 71862129 [A/G] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 Silent,Silent,Silent,Silent,Silent rs3812536 9 71869473 [A/G] NM_001170414,NM_201629,NM_004817,NM_001170415,NM_001170416 TJP2,TJP2,TJP2,TJP2,TJP2 EXON Silent,Silent,Silent,Silent,Silent rs11137746 9 71871790 [A/G] rs7032186 9 71872188 [A/G] rs2039785 9 71873762 [A/C] rs2039787 9 71875458 [T/C] rs11789945 9 71877579 [A/C] rs1538579 9 71883224 [T/C] rs12350141 9 71886979 [A/G] rs2095875 9 71887136 [T/C] rs7868867 9 71888362 [A/C] rs1538581 9 71891756 [A/G] rs17063341 9 71898527 [T/C] rs6559428 9 71901883 [T/C] rs12001191 9 71907945 [A/G] rs7034960 9 71908061 [A/G] rs11138012 9 71916472 [T/C] NR_047671 BANCR Silent rs4744873 9 71917575 [A/G] NR_047671 BANCR Silent rs11138031 9 71918264 [T/C] NR_047671 BANCR Silent rs6559453 9 71926658 [T/C] rs1572762 9 71926960 [A/G] rs1962383 9 71927067 [A/G] rs10780297 9 71935577 [A/C] rs10867357 9 71939431 [A/G] rs1334310 9 71950492 [A/G] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs7041728 9 71953195 [A/C] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs1970162 9 71953719 [A/G] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs10780308 9 71954614 [A/C] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs7033857 9 71962528 [T/C] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs11138262 9 71962651 [A/G] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs7861316 9 71968730 [A/G] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs7466730 9 71973203 [T/C] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs4421413 9 71973435 [T/G] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs4620342 9 71975598 [T/G] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs11138342 9 71985151 [A/G] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs10780321 9 71986805 [A/C] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs4351475 9 71990645 [T/C] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs10867423 9 71991799 [T/G] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs17064047 9 71992403 [T/C] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs6559503 9 71993138 [A/G] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs10780333 9 71998391 [T/G] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 Silent,Silent,Silent rs11138396 9 72000789 [A/G] NM_001127608,NM_001347995,NM_004816 FAM189A2,FAM189A2,FAM189A2 EXON Missense_R261K,Missense_R414K,Missense_R261K rs7033674 9 72008141 [A/G] rs1929896 9 72010915 [T/C] rs11138435 9 72011075 [T/C] rs10867453 9 72016960 [T/G] rs2777877 9 72018961 [A/G] rs2253885 9 72027018 [T/G] rs10113929 9 72027641 [T/G] rs2777860 9 72028323 [A/G] rs11138566 9 72036369 [T/C] rs1757957 9 72042096 [A/C] rs7851002 9 72045565 [T/G] NM_001163 APBA1 EXON Silent rs12351346 9 72045879 [T/C] NM_001163 APBA1 EXON Silent rs1217339 9 72047599 [A/G] NM_001163 APBA1 Silent rs2781530 9 72056397 [T/C] NM_001163 APBA1 Silent rs1806760 9 72058006 [T/C] NM_001163 APBA1 Silent rs2026384 9 72066646 [A/C] NM_001163 APBA1 Silent rs7870154 9 72067786 [T/C] NM_001163 APBA1 Silent rs7869375 9 72067942 [A/G] NM_001163 APBA1 Silent rs4744899 9 72076547 [A/G] NM_001163 APBA1 Silent rs2781536 9 72077866 [T/G] NM_001163 APBA1 Silent rs1761285 9 72080317 [T/C] NM_001163 APBA1 Silent rs1631780 9 72080464 [A/G] NM_001163 APBA1 Silent rs870694 9 72081462 [T/C] NM_001163 APBA1 Silent rs10867613 9 72082970 [A/C] NM_001163 APBA1 Silent rs4744901 9 72087236 [T/C] NM_001163 APBA1 Silent rs2781541 9 72090480 [A/G] NM_001163 APBA1 Silent rs2777862 9 72091104 [T/G] NM_001163 APBA1 Silent rs12001157 9 72100118 [A/G] NM_001163 APBA1 Silent rs7857219 9 72101672 [T/C] NM_001163 APBA1 Silent rs10867647 9 72106629 [A/G] NM_001163 APBA1 Silent rs11138927 9 72107335 [T/C] NM_001163 APBA1 Silent rs10867672 9 72113501 [A/G] NM_001163 APBA1 Silent rs2150878 9 72115231 [A/G] NM_001163 APBA1 Silent rs2309481 9 72115498 [T/C] NM_001163 APBA1 Silent rs7043410 9 72115711 [A/G] NM_001163 APBA1 Silent rs11139063 9 72132199 [A/G] NM_001163 APBA1 Silent rs10481751 9 72134376 [T/G] NM_001163 APBA1 Silent rs12378318 9 72136263 [T/C] NM_001163 APBA1 Silent rs1412243 9 72147700 [T/G] NM_001163 APBA1 Silent rs7851858 9 72148492 [T/C] NM_001163 APBA1 Silent rs1029064 9 72152776 [A/G] NM_001163 APBA1 Silent rs7036538 9 72157077 [T/C] NM_001163 APBA1 Silent rs7858171 9 72160174 [A/C] NM_001163 APBA1 Silent rs1330327 9 72163388 [A/G] NM_001163 APBA1 Silent rs11139300 9 72166621 [A/G] NM_001163 APBA1 Silent rs7864493 9 72167347 [A/G] NM_001163 APBA1 Silent rs12000908 9 72169491 [A/G] NM_001163 APBA1 Silent rs1999215 9 72169944 [A/G] NM_001163 APBA1 Silent rs1970017 9 72174392 [T/C] NM_001163 APBA1 Silent rs11139338 9 72174528 [T/G] NM_001163 APBA1 Silent rs12004586 9 72181521 [A/G] NM_001163 APBA1 Silent rs1330334 9 72204608 [T/G] NM_001163 APBA1 Silent rs12115441 9 72209932 [A/G] NM_001163 APBA1 Silent rs17082946 9 72210569 [T/C] NM_001163 APBA1 Silent rs7853648 9 72213799 [A/G] NM_001163 APBA1 Silent rs10746682 9 72230645 [T/C] NM_001163 APBA1 Silent rs1576508 9 72231803 [T/C] NM_001163 APBA1 Silent rs13288998 9 72233182 [T/G] NM_001163 APBA1 Silent rs10511967 9 72239879 [T/C] NM_001163 APBA1 Silent rs975645 9 72243177 [T/C] NM_001163 APBA1 Silent rs10867845 9 72252269 [A/G] NM_001163 APBA1 Silent rs4629937 9 72252915 [T/C] NM_001163 APBA1 Silent rs7851932 9 72258604 [T/C] NM_001163 APBA1 Silent rs7868291 9 72262481 [T/C] NM_001163 APBA1 Silent rs11139651 9 72273898 [T/C] NM_001163 APBA1 Silent rs10867879 9 72291978 [T/C] rs10867916 9 72303882 [A/G] rs11139900 9 72315423 [T/G] rs7851707 9 72318624 [T/C] rs10867932 9 72322433 [A/G] rs12353216 9 72326135 [A/G] NM_001099666 PTAR1 EXON Silent rs11139923 9 72327557 [A/G] NM_001099666 PTAR1 EXON Silent rs7857137 9 72328727 [A/G] NM_001099666 PTAR1 EXON Silent rs11139997 9 72338610 [T/C] NM_001099666 PTAR1 Silent rs1411411 9 72342930 [A/C] NM_001099666 PTAR1 Silent rs10511969 9 72362158 [T/C] NM_001099666 PTAR1 Silent rs11793130 9 72363992 [T/C] NM_001099666 PTAR1 Silent rs2297172 9 72373346 [A/G] NM_001099666 PTAR1 Silent rs11140189 9 72377357 [T/C] rs1536993 9 72383476 [T/C] rs11521712 9 72398515 [A/G] rs1576483 9 72400437 [T/C] rs6559749 9 72403792 [A/G] rs1819414 9 72405717 [A/G] rs10868073 9 72408691 [T/C] rs17517599 9 72410323 [A/G] rs10119569 9 72411019 [T/C] rs7022623 9 72413613 [A/G] rs9314727 9 72417239 [A/G] rs12349363 9 72418151 [A/G] rs11140368 9 72422919 [T/C] rs2871266 9 72424523 [T/G] rs2183380 9 72425204 [T/C] rs11791776 9 72427015 [T/C] rs4744942 9 72427483 [A/C] rs7863087 9 72429750 [T/C] rs10124812 9 72432080 [T/C] rs7047711 9 72435492 [T/C] NR_038833 C9orf135-DT Silent rs10868131 9 72440451 [T/C] NM_001308086,NM_001308084,NR_131756,NM_001010940,NR_131757,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent,Silent rs10511971 9 72440740 [A/G] NM_001308086,NM_001308084,NR_131756,NM_001010940,NR_131757,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent,Silent rs1330239 9 72441391 [T/C] NM_001308086,NM_001308084,NR_131756,NM_001010940,NR_131757,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent,Silent rs10511972 9 72442540 [T/C] NM_001308086,NM_001308084,NR_131756,NM_001010940,NR_131757,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent,Silent rs4439190 9 72446051 [T/C] NM_001308086,NM_001308084,NR_131756,NM_001010940,NR_131757,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent,Silent rs10521434 9 72448995 [T/C] NM_001308086,NM_001308084,NR_131756,NM_001010940,NR_131757,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent,Silent rs12685383 9 72456491 [A/G] NM_001308086,NM_001308084,NR_131756,NM_001010940,NR_131757,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent,Silent rs1493050 9 72460608 [A/G] NM_001308086,NM_001308084,NR_131756,NM_001010940,NR_131757,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent,Silent rs1389128 9 72464074 [A/C] NM_001308086,NM_001308084,NR_131756,NM_001010940,NR_131757,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent,Silent rs10511973 9 72466275 [A/G] NM_001308086,NM_001308084,NR_131756,NM_001010940,NR_131757,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent,Silent rs10780682 9 72472831 [T/C] NM_001308086,NM_001308084,NR_131756,NM_001010940,NR_131757,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 EXON Synonymous_T30T,Synonymous_T129T,Silent,Synonymous_T129T,Silent,Synonymous_T30T rs7848117 9 72478692 [T/C] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs2035921 9 72479046 [A/G] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs10868224 9 72479663 [T/G] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs766003 9 72480440 [A/G] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs7869694 9 72484697 [A/G] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs12235696 9 72486904 [T/C] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs13284442 9 72488417 [T/C] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs17085936 9 72488442 [A/G] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs4237236 9 72501591 [T/C] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs1027285 9 72505980 [A/G] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs12378305 9 72512292 [T/C] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs10217478 9 72512898 [A/G] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs1907965 9 72513240 [A/G] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs10868248 9 72514177 [A/G] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs10746753 9 72515602 [T/C] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs11140842 9 72519172 [T/C] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs10511974 9 72520270 [A/G] NM_001308086,NM_001308084,NR_131756,NM_001010940,NM_001308085 C9orf135,C9orf135,C9orf135,C9orf135,C9orf135 Silent,Silent,Silent,Silent,Silent rs11140860 9 72523914 [A/C] rs17520192 9 72527688 [A/G] rs10511975 9 72530831 [T/G] rs6559850 9 72531390 [T/C] rs7852214 9 72532067 [T/C] rs12684384 9 72532478 [A/G] rs10511976 9 72535613 [T/C] rs7870323 9 72552407 [A/G] rs7032845 9 72562231 [A/G] rs1493048 9 72562779 [A/G] rs10868315 9 72565221 [A/G] rs1389119 9 72566736 [T/C] rs7041366 9 72569410 [T/C] rs12236860 9 72579310 [A/G] rs4744581 9 72581578 [T/C] rs10511977 9 72590450 [T/G] rs11141099 9 72591329 [A/G] rs11141100 9 72591525 [A/G] rs11141106 9 72593325 [T/G] rs902964 9 72597565 [A/G] rs10868350 9 72598602 [A/C] rs12004635 9 72605832 [A/C] rs10868355 9 72609439 [A/C] rs1565691 9 72609532 [T/C] rs10868358 9 72611680 [T/G] rs10521436 9 72611707 [A/C] rs10868365 9 72621005 [T/G] rs12554412 9 72629662 [T/C] rs12238553 9 72633252 [A/C] rs10868393 9 72634148 [T/G] rs4446788 9 72637119 [A/C] rs12376586 9 72648582 [A/G] rs2975926 9 72648997 [T/C] rs17444393 9 72649864 [T/C] rs11141404 9 72658280 [A/C] rs2997657 9 72662689 [T/C] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs12352964 9 72667128 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs6559939 9 72672537 [T/C] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs2997664 9 72676057 [T/C] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs2997668 9 72679678 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs2997674 9 72683911 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs12686668 9 72696962 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs2997685 9 72707609 [T/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs4237238 9 72710563 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs12000536 9 72712920 [A/C] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs2975881 9 72721009 [T/C] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs3015211 9 72722780 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs1927103 9 72722865 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs2975886 9 72723209 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 EXON Silent,Synonymous_E77E,Synonymous_E77E rs2997708 9 72726356 [A/C] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs2078391 9 72726597 [T/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs3015224 9 72728388 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs4744977 9 72728822 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs10511980 9 72738339 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs10511981 9 72739478 [T/C] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs4744982 9 72749590 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs7856528 9 72765006 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs10780851 9 72766144 [T/C] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs1927117 9 72766414 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs10125454 9 72767405 [A/G] NR_125850,NM_153267,NM_001347990 MAMDC2,MAMDC2,MAMDC2 Silent,Silent,Silent rs10780871 9 72783608 [T/C] NR_125850,NM_153267,NM_001347990,NR_040076 MAMDC2,MAMDC2,MAMDC2,MAMDC2-AS1 Silent,Silent,Silent,Silent rs4744587 9 72785653 [T/G] NR_125850,NM_153267,NM_001347990,NR_040076 MAMDC2,MAMDC2,MAMDC2,MAMDC2-AS1 Silent,Silent,Silent,Silent rs10521438 9 72786881 [A/G] NR_125850,NM_153267,NM_001347990,NR_040076 MAMDC2,MAMDC2,MAMDC2,MAMDC2-AS1 Silent,Silent,Silent,Silent rs1927133 9 72788372 [T/G] NR_125850,NM_153267,NM_001347990,NR_040076 MAMDC2,MAMDC2,MAMDC2,MAMDC2-AS1 Silent,Silent,Silent,Silent rs10114223 9 72792945 [C/G] NR_125850,NM_153267 MAMDC2,MAMDC2 Silent,Silent rs2282068 9 72873252 [A/G] NR_039990 SMC5-AS1 Silent rs1180109 9 72885267 [T/C] NM_015110 SMC5 Silent rs1180116 9 72897434 [A/G] NM_015110 SMC5 EXON Missense_V306I rs1180117 9 72897440 [T/C] NM_015110 SMC5 EXON Missense_C308R rs11142348 9 72897970 [A/G] NM_015110 SMC5 Silent rs10868798 9 72902503 [A/G] NM_015110 SMC5 Silent rs10125617 9 72918167 [T/C] NM_015110 SMC5 Silent rs7049118 9 72951417 [A/G] NM_015110 SMC5 Silent rs3739772 9 72968740 [A/G] NM_015110 SMC5 EXON Silent rs12684881 9 72977345 [T/C] rs10491653 9 72978218 [T/C] rs12347747 9 72979121 [T/C] rs10868811 9 72979246 [T/C] rs4745008 9 72989832 [A/G] rs10780926 9 72993185 [A/G] rs11142387 9 72998332 [A/C] rs11142388 9 72998425 [T/C] rs10780928 9 73009913 [A/G] NM_001206 KLF9 Silent rs7034715 9 73017053 [T/G] NM_001206 KLF9 Silent rs11142402 9 73021070 [T/G] NM_001206 KLF9 Silent rs1056448 9 73028766 [T/C] NM_001206 KLF9 EXON Silent rs10868824 9 73029831 [A/G] rs10868828 9 73038018 [A/G] rs6560132 9 73040468 [T/C] rs915490 9 73065727 [A/G] rs13299473 9 73070585 [T/G] rs7853214 9 73079531 [A/G] rs7873409 9 73080367 [T/G] rs4745013 9 73087603 [A/G] rs2184754 9 73094035 [A/G] rs963266 9 73094295 [A/C] rs11142467 9 73095886 [A/C] rs7029925 9 73101159 [T/C] rs3923699 9 73102824 [T/C] rs17054772 9 73103998 [T/G] rs4548247 9 73104819 [A/G] rs11792173 9 73108351 [T/C] rs7865838 9 73109347 [A/G] rs915488 9 73113806 [A/G] rs7856388 9 73115774 [T/G] rs11999226 9 73120468 [A/C] rs7037072 9 73121298 [A/G] rs10780936 9 73121323 [A/G] rs7854475 9 73125015 [T/G] rs17054874 9 73127939 [T/G] rs10868848 9 73131895 [T/C] rs4436186 9 73133551 [A/G] rs7046672 9 73138287 [T/C] rs4744600 9 73147528 [T/C] rs17535907 9 73149151 [A/G] rs7853385 9 73149897 [T/C] rs17535963 9 73150873 [T/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 EXON Missense_N1554T,Missense_N1556T,Missense_N1566T,Missense_N1569T,Missense_N1707T,Missense_N1579T,Missense_N1544T rs13440436 9 73151110 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 EXON Missense_T1475I,Missense_T1477I,Missense_T1487I,Missense_T1490I,Missense_T1628I,Missense_T1500I,Missense_T1465I rs7033976 9 73151715 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 EXON Synonymous_L1273L,Synonymous_L1275L,Synonymous_L1285L,Synonymous_L1288L,Synonymous_L1426L,Synonymous_L1298L,Synonymous_L1263L rs3739776 9 73151970 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 EXON Synonymous_S1188S,Synonymous_S1190S,Synonymous_S1200S,Synonymous_S1203S,Synonymous_S1341S,Synonymous_S1213S,Synonymous_S1178S rs12338410 9 73161554 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1414850 9 73162236 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2277188 9 73164637 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1889915 9 73164712 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10780947 9 73165078 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6560143 9 73168680 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10511984 9 73170295 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10746847 9 73170382 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4352910 9 73172801 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7021166 9 73173781 [T/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17055312 9 73182122 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10746850 9 73183281 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13290576 9 73191729 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10868854 9 73193371 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10780950 9 73193428 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17055326 9 73193462 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1317103 9 73195703 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17458750 9 73196666 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4744604 9 73199483 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11790957 9 73200907 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10735599 9 73203612 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7865858 9 73204431 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11142498 9 73210302 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4744607 9 73213735 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4615645 9 73218656 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10114679 9 73224560 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3763619 9 73225802 [T/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4269601 9 73227543 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11142508 9 73231662 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7849400 9 73234066 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11142515 9 73239062 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10868861 9 73239605 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11142518 9 73245200 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11142521 9 73248523 [T/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4322073 9 73250037 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12351775 9 73255554 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 EXON Synonymous_D303D,Synonymous_D303D,Synonymous_D303D,Synonymous_D328D,Synonymous_D456D,Synonymous_D328D,Synonymous_D303D rs7849603 9 73261860 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7027906 9 73281358 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7854748 9 73284190 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4465028 9 73287076 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1011308 9 73288256 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1934474 9 73293499 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12345213 9 73294910 [T/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4617221 9 73305723 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10780959 9 73307490 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7023662 9 73309867 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7860377 9 73312129 [A/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11142555 9 73315567 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11142556 9 73315772 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11142561 9 73357667 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12335434 9 73369501 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7875157 9 73369582 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7849151 9 73369687 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4745035 9 73375005 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10868882 9 73378890 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12003443 9 73388919 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs879857 9 73389934 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10868885 9 73391084 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1328148 9 73392983 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6560153 9 73397090 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10435960 9 73398448 [A/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1831143 9 73399750 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7040905 9 73402201 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11142594 9 73405244 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10118380 9 73405864 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1028879 9 73406551 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10868890 9 73408518 [T/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11142598 9 73408650 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7048454 9 73409336 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17055833 9 73412162 [T/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1328153 9 73416062 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17055851 9 73416273 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1410373 9 73416797 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13285335 9 73417675 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7873697 9 73420493 [A/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7863403 9 73421171 [T/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs995903 9 73422925 [A/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs540651 9 73425400 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10868894 9 73427233 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17554439 9 73428066 [A/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7022747 9 73435028 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4526420 9 73436971 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7038646 9 73437824 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7863095 9 73440705 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7862322 9 73440813 [T/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10117842 9 73441437 [A/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2011851 9 73442413 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1034538 9 73442724 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17470402 9 73444920 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10081686 9 73446373 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2039641 9 73448760 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1890017 9 73453045 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7022926 9 73462784 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11142623 9 73470611 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1337026 9 73470756 [T/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10868916 9 73472360 [A/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1415225 9 73472818 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17555916 9 73473596 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11142627 9 73474633 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10511988 9 73476497 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17556165 9 73477141 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12553375 9 73478213 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12003687 9 73480240 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1337024 9 73480626 [A/G] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1415221 9 73480718 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12378024 9 73482440 [T/C] NM_020952,NM_206945,NM_024971,NM_206947,NM_001007471,NM_206946,NM_206944,NM_206948,NM_001007470 TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3,TRPM3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3812530 9 73485048 [A/G] NM_001007471 TRPM3 Silent rs7856482 9 73485446 [A/G] NM_001007471 TRPM3 Silent rs13293998 9 73488564 [T/C] NM_001007471 TRPM3 Silent rs9792446 9 73490171 [A/G] NM_001007471 TRPM3 Silent rs9792690 9 73490284 [T/C] NM_001007471 TRPM3 Silent rs4532663 9 73492507 [A/G] NM_001007471 TRPM3 Silent rs1890016 9 73493728 [A/G] NM_001007471 TRPM3 Silent rs11142635 9 73494438 [T/C] NM_001007471 TRPM3 Silent rs13283806 9 73494939 [T/C] NM_001007471 TRPM3 Silent rs17471974 9 73496967 [T/G] NM_001007471 TRPM3 Silent rs7021176 9 73497518 [A/G] NM_001007471 TRPM3 Silent rs11142636 9 73500481 [A/G] NM_001007471 TRPM3 Silent rs7851915 9 73500857 [T/C] NM_001007471 TRPM3 Silent rs10780982 9 73502424 [T/G] NM_001007471 TRPM3 Silent rs1361028 9 73502636 [A/G] NM_001007471 TRPM3 Silent rs13285568 9 73504145 [A/C] NM_001007471 TRPM3 Silent rs1337033 9 73507057 [A/G] NM_001007471 TRPM3 Silent rs10511992 9 73507096 [T/C] NM_001007471 TRPM3 Silent rs11142639 9 73508497 [A/G] NM_001007471 TRPM3 Silent rs7046928 9 73508552 [T/C] NM_001007471 TRPM3 Silent rs13287493 9 73508693 [T/C] NM_001007471 TRPM3 Silent rs17472220 9 73509677 [T/C] NM_001007471 TRPM3 Silent rs2993013 9 73510880 [A/C] NM_001007471 TRPM3 Silent rs7868945 9 73514958 [A/G] NM_001007471 TRPM3 Silent rs10868926 9 73515771 [T/C] NM_001007471 TRPM3 Silent rs4143736 9 73517105 [A/G] NM_001007471 TRPM3 Silent rs10868928 9 73525515 [T/C] NM_001007471 TRPM3 Silent rs1337036 9 73527458 [A/G] NM_001007471 TRPM3 Silent rs9696174 9 73532529 [T/C] NM_001007471 TRPM3 Silent rs3010419 9 73536416 [A/G] NM_001007471 TRPM3 Silent rs7849064 9 73538154 [A/G] NM_001007471 TRPM3 Silent rs3010421 9 73539365 [T/C] NM_001007471 TRPM3 Silent rs1337009 9 73540269 [A/C] NM_001007471 TRPM3 Silent rs1415219 9 73547108 [T/C] NM_001007471 TRPM3 Silent rs1337013 9 73547773 [T/C] NM_001007471 TRPM3 Silent rs12347867 9 73557169 [A/G] NM_001007471 TRPM3 Silent rs1981161 9 73563097 [A/C] NM_001007471 TRPM3 Silent rs12377705 9 73564396 [A/G] NM_001007471 TRPM3 Silent rs2993000 9 73567734 [A/G] NM_001007471 TRPM3 Silent rs2993001 9 73567782 [A/G] NM_001007471 TRPM3 Silent rs945688 9 73574860 [T/C] NM_001007471 TRPM3 Silent rs1108226 9 73575662 [T/C] NM_001007471 TRPM3 Silent rs2993003 9 73577326 [A/G] NM_001007471 TRPM3 Silent rs7863158 9 73583539 [A/G] NM_001007471 TRPM3 Silent rs2993008 9 73586356 [T/C] NM_001007471 TRPM3 Silent rs3010434 9 73586559 [T/C] NM_001007471 TRPM3 Silent rs7857794 9 73587520 [A/G] NM_001007471 TRPM3 Silent rs12351733 9 73590123 [A/G] NM_001007471 TRPM3 Silent rs10868934 9 73590376 [T/C] NM_001007471 TRPM3 Silent rs3010438 9 73593866 [T/C] NM_001007471 TRPM3 Silent rs1558924 9 73598308 [T/C] NM_001007471 TRPM3 Silent rs10868936 9 73598428 [T/C] NM_001007471 TRPM3 Silent rs1558926 9 73598465 [A/G] NM_001007471 TRPM3 Silent rs10868937 9 73598950 [A/G] NM_001007471 TRPM3 Silent rs13293692 9 73599125 [T/G] NM_001007471 TRPM3 Silent rs7857162 9 73599501 [T/C] NM_001007471 TRPM3 Silent rs719788 9 73600430 [A/C] NM_001007471 TRPM3 Silent rs1558928 9 73602628 [A/G] NM_001007471 TRPM3 Silent rs12554003 9 73610288 [T/C] NM_001007471 TRPM3 Silent rs11142667 9 73614737 [T/C] NM_001007471 TRPM3 Silent rs2909292 9 73615374 [T/C] NM_001007471 TRPM3 Silent rs13298352 9 73621122 [T/G] NM_001007471 TRPM3 Silent rs978790 9 73632244 [T/C] NM_001007471 TRPM3 Silent rs495259 9 73632464 [A/G] NM_001007471 TRPM3 Silent rs12551768 9 73633405 [T/C] NM_001007471 TRPM3 Silent rs11142672 9 73644816 [A/G] NM_001007471 TRPM3 Silent rs1411164 9 73655072 [A/C] NM_001007471 TRPM3 Silent rs6560173 9 73656077 [A/G] NM_001007471 TRPM3 Silent rs672801 9 73674356 [A/C] NM_001007471 TRPM3 Silent rs523734 9 73680233 [T/C] NM_001007471 TRPM3 Silent rs11142684 9 73691183 [T/C] NM_001007471 TRPM3 Silent rs552849 9 73695760 [T/C] NM_001007471 TRPM3 Silent rs13285838 9 73697886 [T/G] NM_001007471 TRPM3 Silent rs656875 9 73702948 [A/G] NM_001007471 TRPM3 Silent rs667136 9 73709579 [A/G] NM_001007471 TRPM3 Silent rs7026563 9 73711655 [T/C] NM_001007471 TRPM3 Silent rs1329748 9 73718807 [A/G] NM_001007471 TRPM3 Silent rs972386 9 73722116 [T/C] NM_001007471 TRPM3 Silent rs17056295 9 73728358 [A/G] NM_001007471 TRPM3 Silent rs662975 9 73742312 [A/G] rs2183301 9 73746381 [A/G] rs7046666 9 73753420 [A/C] rs10868959 9 73753735 [A/G] rs10732700 9 73753749 [T/C] rs1888076 9 73755434 [A/C] rs4744622 9 73757570 [A/C] rs10746858 9 73759434 [T/G] rs12349882 9 73762488 [T/C] rs12686625 9 73765910 [T/C] rs17056365 9 73768548 [A/G] rs10868962 9 73769283 [T/G] rs11142707 9 73775105 [T/C] rs2031976 9 73775928 [A/G] rs11142708 9 73778502 [A/G] rs6560182 9 73782712 [A/G] rs7040038 9 73786741 [A/G] rs10868969 9 73796648 [T/C] rs1329767 9 73798371 [A/C] rs4745065 9 73799703 [A/C] rs10512009 9 73801266 [T/C] rs7862138 9 73801739 [A/G] rs17056479 9 73820503 [T/G] rs7018911 9 73828288 [T/C] rs4745072 9 73833825 [A/G] rs6560191 9 73836535 [T/C] rs2209912 9 73846442 [A/G] rs11142747 9 73850169 [T/C] rs11142750 9 73856839 [T/G] rs9785312 9 73859086 [A/C] rs4745077 9 73861353 [T/C] rs17056622 9 73873692 [T/C] rs11142760 9 73877070 [T/C] rs10781005 9 73879320 [T/C] rs10781009 9 73886505 [T/C] rs11142771 9 73888408 [T/C] rs7031863 9 73891675 [T/C] rs7850256 9 73894279 [T/C] rs7022575 9 73895545 [A/C] rs10869010 9 73896545 [T/G] rs13285637 9 73902148 [A/G] rs1504388 9 73902470 [A/G] rs1532803 9 73903664 [T/C] rs11142786 9 73907625 [T/C] rs1604856 9 73909625 [T/C] rs13300497 9 73909781 [A/G] rs17533283 9 73909871 [A/G] rs11142792 9 73914256 [T/C] rs11142794 9 73914605 [T/G] rs1566837 9 73915883 [A/G] rs7023772 9 73920359 [T/C] rs2134860 9 73920739 [A/C] rs4142472 9 73925831 [A/G] rs1472730 9 73929083 [T/C] rs4744628 9 73931778 [A/G] rs17617904 9 73935165 [T/C] rs10781013 9 73935754 [A/G] rs17617922 9 73936166 [T/C] rs11792896 9 73940190 [T/C] rs1897258 9 73953144 [A/G] rs7852227 9 73958026 [A/G] rs11142806 9 73967943 [A/G] rs11142807 9 73970949 [A/C] rs4744630 9 73973798 [T/C] rs4744631 9 73977066 [A/G] rs10512007 9 73995267 [T/C] rs12352829 9 74006667 [A/G] rs1074670 9 74016773 [A/G] rs1891301 9 74018496 [T/C] rs10118280 9 74021451 [A/G] rs7852943 9 74036883 [A/G] rs12344569 9 74037537 [T/C] rs1935338 9 74039166 [T/C] rs4469528 9 74042233 [T/C] rs10869019 9 74042353 [T/C] rs12375722 9 74050819 [T/C] rs10116204 9 74052978 [T/C] rs12238624 9 74059199 [T/C] rs4745087 9 74061310 [T/C] rs12002628 9 74067610 [T/C] rs1821070 9 74070471 [A/C] rs7034150 9 74072841 [A/G] rs10869025 9 74080676 [T/C] rs11507232 9 74085486 [A/G] rs11142845 9 74096528 [T/C] rs10869028 9 74101337 [T/C] rs10869029 9 74103833 [T/C] rs4549848 9 74104808 [A/G] rs2309966 9 74115344 [A/C] rs1891296 9 74119863 [T/C] rs2309968 9 74122340 [A/C] rs10869031 9 74130286 [T/G] rs11142863 9 74135468 [T/C] rs11791628 9 74136094 [A/G] rs11142873 9 74151806 [T/C] rs2309974 9 74152609 [T/C] rs2309975 9 74154710 [A/G] rs10124132 9 74157998 [T/C] rs7042172 9 74158641 [A/G] rs17056975 9 74158862 [A/G] rs2309979 9 74167402 [T/C] rs10746878 9 74171129 [T/C] rs7876052 9 74172458 [T/C] rs2309982 9 74174742 [A/G] rs1962243 9 74175428 [A/G] rs2309983 9 74175647 [T/C] rs2232139 9 74176418 [T/G] rs7043834 9 74176852 [A/G] rs10124877 9 74179834 [A/G] rs11142892 9 74181734 [T/C] rs4606122 9 74186310 [T/C] rs11142895 9 74192592 [T/C] rs1410983 9 74194133 [T/C] rs13287882 9 74199338 [T/C] rs9314788 9 74199813 [T/C] rs2210016 9 74200674 [A/G] rs11142904 9 74202802 [T/C] rs11142906 9 74204367 [T/C] rs10869044 9 74205232 [T/C] rs11142907 9 74207521 [A/C] rs12353518 9 74208282 [A/G] rs4069914 9 74228247 [A/G] rs1329411 9 74229859 [A/G] rs868147 9 74244432 [A/G] rs11142927 9 74244754 [T/C] rs13293927 9 74245097 [A/G] rs10781030 9 74245141 [A/G] rs6560217 9 74245268 [T/C] rs4745104 9 74246308 [T/C] rs4745106 9 74248170 [A/C] rs1928423 9 74250387 [A/C] rs2201127 9 74254313 [T/C] rs2871401 9 74257162 [A/C] rs2087716 9 74258824 [A/G] rs10781032 9 74260812 [A/G] rs10746883 9 74261572 [T/C] rs2131039 9 74262200 [T/C] rs1410989 9 74265535 [A/G] rs11142947 9 74266320 [A/G] rs6560223 9 74268686 [A/G] rs970481 9 74270167 [A/G] rs970480 9 74270232 [T/C] rs11142949 9 74272001 [A/G] rs7854239 9 74277315 [A/G] rs11142952 9 74278480 [T/C] rs4745109 9 74279487 [T/C] rs4745111 9 74281371 [T/C] rs11142955 9 74283609 [T/C] rs1887971 9 74285850 [A/G] rs4745112 9 74292618 [T/C] rs10511999 9 74296497 [A/C] rs10511998 9 74297245 [A/G] rs6560226 9 74298720 [A/G] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 EXON Silent,Silent,Silent rs7031344 9 74299442 [A/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 EXON Silent,Silent,Silent rs2310021 9 74300640 [A/G] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs4745114 9 74304506 [A/G] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs17475375 9 74305020 [T/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 EXON Missense_G642D,Missense_G1217D,Missense_G1280D rs2297089 9 74305098 [T/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 EXON Missense_S616N,Missense_S1191N,Missense_S1254N rs3780605 9 74308389 [T/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs4745115 9 74311310 [T/G] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs4745116 9 74311872 [T/G] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs1293 9 74312747 [A/G] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs17057129 9 74313429 [A/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs11142963 9 74318137 [T/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs17057133 9 74319677 [T/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 EXON Missense_I372V,Missense_I947V,Missense_I1010V rs12341685 9 74321381 [T/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs7046059 9 74324149 [A/G] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs1010434 9 74325433 [T/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs3739781 9 74326961 [A/G] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs7037458 9 74327419 [A/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs2307005 9 74332784 [T/G] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs11142978 9 74340910 [A/G] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs25694 9 74345158 [A/G] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 EXON Silent,Synonymous_T532T,Synonymous_T595T rs7030493 9 74348424 [T/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs2274698 9 74350002 [A/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs25690 9 74355028 [A/G] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 EXON Silent,Synonymous_T385T,Synonymous_T385T rs3753006 9 74355185 [T/G] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs25688 9 74360234 [T/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 EXON Silent,Missense_R245K,Missense_R245K rs7859152 9 74373298 [T/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs2310024 9 74374194 [T/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs7030211 9 74378277 [T/C] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs12555916 9 74381599 [A/G] NM_001349784,NM_001135820,NM_013390 CEMIP2,CEMIP2,CEMIP2 Silent,Silent,Silent rs1404195 9 74384876 [T/C] rs4745122 9 74392687 [A/C] rs4745123 9 74393843 [A/G] rs990449 9 74401123 [T/C] rs10511995 9 74410755 [A/C] rs11143006 9 74414358 [A/C] rs1464758 9 74427419 [T/C] rs1815118 9 74437600 [A/G] rs2310041 9 74445353 [T/C] rs7025473 9 74463295 [A/G] rs1568788 9 74474118 [A/G] rs10122259 9 74477182 [T/C] rs1404190 9 74491379 [T/G] NM_016014,NM_001025780 ABHD17B,ABHD17B Silent,Silent rs7871375 9 74502009 [T/C] NM_016014,NM_001025780 ABHD17B,ABHD17B Silent,Silent rs10746893 9 74505254 [A/G] NM_016014,NM_001025780 ABHD17B,ABHD17B Silent,Silent rs10781048 9 74527096 [T/C] NM_182505 C9orf85 Silent rs13299567 9 74532618 [A/G] NM_182505 C9orf85 Silent rs4744648 9 74534600 [T/C] NM_182505 C9orf85 Silent rs17491074 9 74552234 [A/G] NM_182505 C9orf85 Silent rs11143035 9 74556808 [A/G] NM_182505 C9orf85 Silent rs10120169 9 74561883 [A/G] NM_182505 C9orf85 Silent rs11143040 9 74575181 [T/C] NM_182505 C9orf85 Silent rs10781055 9 74588595 [T/C] rs7030498 9 74599651 [A/G] rs7046123 9 74600212 [A/C] rs10869073 9 74600517 [T/C] rs2147241 9 74602933 [T/C] rs10869076 9 74607151 [A/G] rs942391 9 74610494 [A/G] rs11787649 9 74612197 [T/C] rs942390 9 74619041 [A/G] rs12682751 9 74621568 [T/C] rs13285788 9 74622195 [T/C] rs10869078 9 74626896 [A/G] rs956090 9 74630070 [T/G] rs2147244 9 74637129 [A/G] rs4745150 9 74642649 [A/G] rs4745152 9 74649339 [A/G] rs9314790 9 74653124 [T/C] rs1806868 9 74664333 [T/C] rs1570638 9 74667770 [T/C] NM_001128618 C9orf57 Silent rs4744654 9 74668310 [T/C] NM_001128618 C9orf57 Silent rs7039742 9 74668581 [T/C] NM_001128618 C9orf57 Silent rs7047632 9 74674427 [A/C] NM_001128618 C9orf57 Silent rs12345527 9 74675604 [T/C] rs10869092 9 74679126 [T/G] rs7030573 9 74679454 [T/C] rs10869094 9 74683057 [A/G] rs10781064 9 74695444 [A/C] rs10746902 9 74698289 [A/C] rs10735611 9 74724989 [T/C] rs10435966 9 74728011 [T/C] rs4416886 9 74733695 [T/C] NM_001242507 GDA Silent rs4744660 9 74733832 [A/C] NM_001242507 GDA Silent rs9314794 9 74737437 [T/C] NM_001242507 GDA Silent rs4745160 9 74739999 [T/C] NM_001242507 GDA Silent rs4745167 9 74745434 [A/C] NM_001242507 GDA Silent rs10869127 9 74747787 [T/G] NM_001242507 GDA Silent rs12004332 9 74752849 [T/C] NM_001242507 GDA Silent rs10781076 9 74756542 [T/C] NM_001242507 GDA Silent rs10511997 9 74760556 [A/G] NM_001242507 GDA Silent rs4745173 9 74761921 [T/C] NM_001242507 GDA Silent rs28723000 9 74763225 [A/G] NM_001242507 GDA Silent rs7036479 9 74763415 [T/C] NM_001242507 GDA Silent rs7021424 9 74763426 [A/G] NM_001242507 GDA Silent rs4540461 9 74773148 [A/G] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10869134 9 74776701 [A/G] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10869137 9 74779404 [T/G] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10869142 9 74797309 [T/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4484759 9 74800525 [T/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10781084 9 74814458 [T/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10781085 9 74814485 [A/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17494172 9 74819084 [A/G] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11143168 9 74821250 [T/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11143170 9 74825707 [T/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7030035 9 74827066 [T/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7861301 9 74828339 [A/G] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17494333 9 74828973 [A/G] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs5025470 9 74832555 [T/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10869148 9 74834384 [T/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10869149 9 74836247 [T/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13295564 9 74842516 [T/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10869150 9 74845989 [A/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4347048 9 74852304 [A/G] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13298009 9 74852965 [T/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11143193 9 74853935 [T/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4130866 9 74858118 [T/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2208744 9 74865077 [A/C] NM_001242507,NR_147240,NM_001242505,NM_004293,NM_001242506,NM_001351572,NM_001351571,NM_001351573 GDA,GDA,GDA,GDA,GDA,GDA,GDA,GDA EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7029217 9 74870018 [T/C] rs11143202 9 74871708 [T/C] rs969460 9 74874951 [T/C] rs10869157 9 74878937 [A/C] rs1322480 9 74879449 [A/G] rs11143216 9 74882572 [A/C] rs7863783 9 74884103 [T/C] rs11143224 9 74885915 [A/G] rs11143230 9 74887703 [A/C] rs7859318 9 74888969 [A/G] rs7875593 9 74892709 [A/G] rs881510 9 74892832 [A/G] rs2871427 9 74893024 [A/G] rs1998372 9 74894172 [T/C] rs11143233 9 74897034 [A/G] rs4997577 9 74897271 [A/G] rs4745182 9 74907597 [T/C] rs7846745 9 74909843 [T/C] rs12378224 9 74913868 [A/C] rs10746908 9 74921643 [T/C] NR_110952,NR_110953 LINC01504,LINC01504 Silent,Silent rs911861 9 74921883 [T/C] NR_110952,NR_110953 LINC01504,LINC01504 Silent,Silent rs1322484 9 74923489 [A/G] NR_110952,NR_110953 LINC01504,LINC01504 Silent,Silent rs17057618 9 74925179 [A/C] NR_110952,NR_110953 LINC01504,LINC01504 Silent,Silent rs4745183 9 74927609 [T/C] NR_110952,NR_110953 LINC01504,LINC01504 Silent,Silent rs9411042 9 74932819 [A/G] NR_110952 LINC01504 Silent rs2104188 9 74938125 [T/C] NR_110952 LINC01504 Silent rs13439944 9 74940364 [A/G] NR_110952 LINC01504 Silent rs9411047 9 74944437 [T/C] NR_110952 LINC01504 Silent rs11143267 9 74948556 [A/G] NR_110952 LINC01504 Silent rs1547097 9 74952524 [T/C] NR_110952 LINC01504 Silent rs7849626 9 74956781 [A/C] NR_110952 LINC01504 EXON Silent rs12349878 9 74968193 [T/C] NM_001278244,NM_001278245,NM_006007,NM_001102421,NM_001278243,NM_001102420 ZFAND5,ZFAND5,ZFAND5,ZFAND5,ZFAND5,ZFAND5 EXON Silent,Silent,Silent,Silent,Silent,Silent rs3398 9 74969076 [A/G] NM_001278244,NM_001278245,NM_006007,NM_001102421,NM_001278243,NM_001102420 ZFAND5,ZFAND5,ZFAND5,ZFAND5,ZFAND5,ZFAND5 EXON Silent,Silent,Silent,Silent,Silent,Silent rs969 9 74969864 [T/C] NM_001278244,NM_001278245,NM_006007,NM_001102421,NM_001278243,NM_001102420 ZFAND5,ZFAND5,ZFAND5,ZFAND5,ZFAND5,ZFAND5 EXON Silent,Silent,Silent,Silent,Silent,Silent rs17057662 9 74972397 [T/G] NM_001278244,NM_001278245,NM_006007,NM_001102421,NM_001278243,NM_001102420 ZFAND5,ZFAND5,ZFAND5,ZFAND5,ZFAND5,ZFAND5 Silent,Silent,Silent,Silent,Silent,Silent rs1853276 9 74975711 [T/C] NM_001278244,NM_001278245,NM_006007,NM_001102421,NM_001278243,NM_001102420 ZFAND5,ZFAND5,ZFAND5,ZFAND5,ZFAND5,ZFAND5 Silent,Silent,Silent,Silent,Silent,Silent rs2984524 9 74989643 [T/C] rs2984519 9 74997987 [A/G] rs3012511 9 75012258 [A/G] rs7027119 9 75021841 [A/C] rs17057698 9 75021851 [A/G] rs7846808 9 75027824 [T/G] rs10781101 9 75046564 [T/C] rs12340416 9 75054615 [T/C] rs6560275 9 75059164 [T/C] rs17057755 9 75072188 [T/C] rs11143303 9 75078002 [A/C] rs10511996 9 75081322 [A/C] rs10869180 9 75092054 [T/G] rs7023338 9 75096601 [A/G] rs12005469 9 75096610 [A/G] rs10121019 9 75099616 [T/C] rs7040392 9 75112780 [T/C] rs7857674 9 75123453 [T/G] rs10124859 9 75129891 [T/C] rs10869183 9 75135825 [T/C] rs13291144 9 75135912 [T/C] rs7022441 9 75136789 [A/G] NM_138691 TMC1 EXON Silent rs12353502 9 75139296 [A/G] NM_138691 TMC1 Silent rs12351107 9 75144147 [T/C] NM_138691 TMC1 Silent rs3935574 9 75148230 [T/G] NM_138691 TMC1 Silent rs7875995 9 75172587 [T/C] NM_138691 TMC1 Silent rs7856874 9 75177017 [A/G] NM_138691 TMC1 Silent rs7851121 9 75187959 [A/G] NM_138691 TMC1 Silent rs7864744 9 75188225 [T/G] NM_138691 TMC1 Silent rs9942926 9 75188446 [A/G] NM_138691 TMC1 Silent rs12344734 9 75193543 [A/C] NM_138691 TMC1 Silent rs12344850 9 75193817 [T/C] NM_138691 TMC1 Silent rs7026124 9 75194978 [T/C] NM_138691 TMC1 Silent rs7853366 9 75200657 [A/G] NM_138691 TMC1 Silent rs7029452 9 75207329 [A/G] NM_138691 TMC1 Silent rs7045535 9 75210243 [T/C] NM_138691 TMC1 Silent rs13285932 9 75211603 [T/C] NM_138691 TMC1 Silent rs1899937 9 75218470 [T/G] NM_138691 TMC1 Silent rs920901 9 75229248 [A/G] NM_138691 TMC1 Silent rs10217204 9 75231217 [A/G] NM_138691 TMC1 Silent rs7026304 9 75231370 [A/G] NM_138691 TMC1 EXON Silent rs10156444 9 75232433 [A/G] NM_138691 TMC1 Silent rs11143354 9 75246292 [A/G] NM_138691 TMC1 Silent rs11143358 9 75253092 [T/C] NM_138691 TMC1 Silent rs17058062 9 75262770 [A/G] NM_138691 TMC1 Silent rs1663762 9 75276898 [A/G] NM_138691 TMC1 Silent rs12339514 9 75284559 [A/C] NM_138691 TMC1 Silent rs1417614 9 75295593 [T/C] NM_138691 TMC1 Silent rs1444832 9 75307719 [T/C] NM_138691 TMC1 Silent rs1796993 9 75315438 [A/G] NM_138691 TMC1 EXON Missense_E81K rs12552056 9 75316142 [T/G] NM_138691 TMC1 Silent rs2793162 9 75331221 [T/C] NM_138691 TMC1 Silent rs2487464 9 75343789 [T/C] NM_138691 TMC1 Silent rs2589632 9 75349586 [A/G] NM_138691 TMC1 Silent rs1341032 9 75352123 [T/C] NM_138691 TMC1 Silent rs2589628 9 75354330 [A/G] NM_138691 TMC1 Silent rs10481772 9 75365926 [T/C] NM_138691 TMC1 Silent rs1550760 9 75375810 [T/G] NM_138691 TMC1 Silent rs7863483 9 75382598 [T/C] NM_138691 TMC1 Silent rs1341033 9 75391254 [T/C] NM_138691 TMC1 Silent rs13285263 9 75400088 [A/C] NM_138691 TMC1 Silent rs17058153 9 75407159 [T/C] NM_138691 TMC1 EXON Missense_M486T rs2994693 9 75414490 [A/G] NM_138691 TMC1 Silent rs17641064 9 75415331 [T/C] NM_138691 TMC1 Silent rs11999588 9 75444298 [T/C] NM_138691 TMC1 Silent rs4330753 9 75445904 [A/C] NM_138691 TMC1 Silent rs13285182 9 75452560 [A/G] rs7027182 9 75459316 [T/C] rs3905336 9 75470360 [T/C] rs1991095 9 75488122 [A/G] NR_121181,NR_121120,NR_121180 LINC01474,LINC01474,LINC01474 Silent,Silent,Silent rs660519 9 75498014 [T/C] rs13292949 9 75500490 [T/G] rs11999628 9 75507239 [T/G] rs10869198 9 75507770 [T/C] rs618596 9 75510629 [T/C] rs617590 9 75510887 [T/C] rs7873724 9 75512127 [A/G] rs348479 9 75512300 [T/G] rs12002950 9 75513378 [T/G] rs348480 9 75513722 [T/C] rs12342202 9 75513903 [A/G] rs348481 9 75514436 [T/C] rs348483 9 75515114 [T/C] rs17058197 9 75515133 [T/C] rs348484 9 75515325 [A/G] rs348485 9 75515454 [T/C] rs4646548 9 75515546 [A/G] rs8188000 9 75515669 [T/C] NM_000689 ALDH1A1 EXON Silent rs8187998 9 75516062 [T/C] NM_000689 ALDH1A1 EXON Silent rs8187995 9 75516731 [A/G] NM_000689 ALDH1A1 Silent rs12000845 9 75517062 [T/C] NM_000689 ALDH1A1 Silent rs8187993 9 75517433 [T/A] NM_000689 ALDH1A1 Silent rs4646547 9 75517582 [A/C] NM_000689 ALDH1A1 Silent rs8187991 9 75517583 [A/G] NM_000689 ALDH1A1 Silent rs8187989 9 75518018 [A/C] NM_000689 ALDH1A1 Silent rs8187988 9 75518097 [T/G] NM_000689 ALDH1A1 Silent rs2113458 9 75519371 [T/C] NM_000689 ALDH1A1 Silent rs8187986 9 75519946 [A/C] NM_000689 ALDH1A1 Silent rs348471 9 75519975 [A/G] NM_000689 ALDH1A1 Silent rs348472 9 75521060 [A/G] NM_000689 ALDH1A1 Silent rs17058219 9 75521188 [T/C] NM_000689 ALDH1A1 Silent rs8187984 9 75521325 [T/C] NM_000689 ALDH1A1 Silent rs1330291 9 75521702 [T/C] NM_000689 ALDH1A1 Silent rs8187981 9 75521938 [T/C] NM_000689 ALDH1A1 Silent rs8187980 9 75521961 [T/C] NM_000689 ALDH1A1 Silent rs8187979 9 75522147 [A/G] NM_000689 ALDH1A1 Silent rs17058224 9 75522835 [A/C] NM_000689 ALDH1A1 Silent rs1888203 9 75523857 [T/C] NM_000689 ALDH1A1 Silent rs348474 9 75523871 [T/C] NM_000689 ALDH1A1 Silent rs348475 9 75525879 [A/G] NM_000689 ALDH1A1 Silent rs8187976 9 75525939 [A/G] NM_000689 ALDH1A1 Silent rs348476 9 75526517 [T/C] NM_000689 ALDH1A1 Silent rs8187974 9 75526866 [A/C] NM_000689 ALDH1A1 Silent rs8187973 9 75527088 [A/G] NM_000689 ALDH1A1 Silent rs8187971 9 75527842 [A/G] NM_000689 ALDH1A1 Silent rs348477 9 75528762 [A/G] NM_000689 ALDH1A1 Silent rs8187968 9 75528958 [A/G] NM_000689 ALDH1A1 Silent rs8187966 9 75529087 [T/G] NM_000689 ALDH1A1 Silent rs13296621 9 75529096 [A/G] NM_000689 ALDH1A1 Silent rs8187965 9 75529173 [A/G] NM_000689 ALDH1A1 Silent rs7871253 9 75529423 [A/G] NM_000689 ALDH1A1 Silent rs8187964 9 75529470 [T/C] NM_000689 ALDH1A1 Silent rs8187961 9 75529783 [T/C] NM_000689 ALDH1A1 Silent rs348458 9 75529888 [T/C] NM_000689 ALDH1A1 Silent rs8187959 9 75529941 [A/G] NM_000689 ALDH1A1 Silent rs4744674 9 75530921 [C/G] NM_000689 ALDH1A1 Silent rs1411425 9 75531371 [T/G] NM_000689 ALDH1A1 Silent rs1424488 9 75532604 [A/G] NM_000689 ALDH1A1 Silent rs8187955 9 75532967 [T/C] NM_000689 ALDH1A1 Silent rs610529 9 75533324 [A/G] NM_000689 ALDH1A1 Silent rs2161810 9 75534262 [A/G] NM_000689 ALDH1A1 Silent rs8187952 9 75534604 [A/G] NM_000689 ALDH1A1 Silent rs8187951 9 75534663 [A/C] NM_000689 ALDH1A1 Silent rs348460 9 75534760 [T/G] NM_000689 ALDH1A1 Silent rs8187950 9 75535038 [A/G] NM_000689 ALDH1A1 Silent rs8187949 9 75535052 [A/G] NM_000689 ALDH1A1 Silent rs8187948 9 75535218 [A/G] NM_000689 ALDH1A1 Silent rs8187947 9 75535227 [A/C] NM_000689 ALDH1A1 Silent rs11143418 9 75536654 [A/G] NM_000689 ALDH1A1 Silent rs10869199 9 75536786 [A/G] NM_000689 ALDH1A1 Silent rs8187945 9 75537298 [A/G] NM_000689 ALDH1A1 Silent rs8187944 9 75537406 [A/G] NM_000689 ALDH1A1 Silent rs348459 9 75537590 [T/C] NM_000689 ALDH1A1 Silent rs8187941 9 75538122 [T/C] NM_000689 ALDH1A1 Silent rs8187940 9 75538278 [T/C] NM_000689 ALDH1A1 Silent rs4646544 9 75538297 [T/G] NM_000689 ALDH1A1 Silent rs8187939 9 75538302 [T/C] NM_000689 ALDH1A1 Silent rs8187936 9 75538725 [A/C] NM_000689 ALDH1A1 Silent rs3739962 9 75539077 [A/G] NM_000689 ALDH1A1 Silent rs13302421 9 75540027 [A/C] NM_000689 ALDH1A1 Silent rs2161811 9 75540187 [A/G] NM_000689 ALDH1A1 Silent rs8187930 9 75540393 [T/G] NM_000689 ALDH1A1 Silent rs8187929 9 75540504 [A/T] NM_000689 ALDH1A1 EXON Missense_I177F rs2288086 9 75540572 [A/G] NM_000689 ALDH1A1 Silent rs8187928 9 75540828 [T/C] NM_000689 ALDH1A1 Silent rs8187926 9 75541723 [T/C] NM_000689 ALDH1A1 Silent rs2303317 9 75541942 [T/G] NM_000689 ALDH1A1 Silent rs8187925 9 75541962 [A/C] NM_000689 ALDH1A1 Silent rs7043217 9 75542895 [A/G] NM_000689 ALDH1A1 Silent rs11143419 9 75543046 [G/C] NM_000689 ALDH1A1 Silent rs8187924 9 75543243 [A/G] NM_000689 ALDH1A1 Silent rs8187923 9 75543480 [T/C] NM_000689 ALDH1A1 Silent rs2017362 9 75544391 [T/C] NM_000689 ALDH1A1 Silent rs1364457 9 75544523 [A/C] NM_000689 ALDH1A1 Silent rs8187919 9 75544797 [A/G] NM_000689 ALDH1A1 Silent rs4237253 9 75544932 [T/C] NM_000689 ALDH1A1 Silent rs4237254 9 75545060 [T/G] NM_000689 ALDH1A1 Silent rs4237255 9 75545140 [T/G] NM_000689 ALDH1A1 Silent rs4646543 9 75545456 [T/C] NM_000689 ALDH1A1 Silent rs3815836 9 75545638 [A/C] NM_000689 ALDH1A1 Silent rs13959 9 75545882 [A/G] NM_000689 ALDH1A1 EXON Synonymous_S75S rs8187914 9 75546055 [T/C] NM_000689 ALDH1A1 Silent rs959669 9 75546165 [A/G] NM_000689 ALDH1A1 Silent rs8187912 9 75547252 [T/C] NM_000689 ALDH1A1 Silent rs8187911 9 75547278 [T/C] NM_000689 ALDH1A1 Silent rs4646541 9 75547581 [A/G] NM_000689 ALDH1A1 Silent rs348463 9 75547612 [T/C] NM_000689 ALDH1A1 Silent rs8187910 9 75549810 [T/C] NM_000689 ALDH1A1 Silent rs12683230 9 75550383 [T/C] NM_000689 ALDH1A1 Silent rs8187907 9 75550468 [T/C] NM_000689 ALDH1A1 Silent rs7851899 9 75550675 [A/G] NM_000689 ALDH1A1 Silent rs7852860 9 75550741 [A/C] NM_000689 ALDH1A1 Silent rs8187905 9 75551011 [A/C] NM_000689 ALDH1A1 Silent rs8187904 9 75551220 [A/G] NM_000689 ALDH1A1 Silent rs2773806 9 75551300 [T/C] NM_000689 ALDH1A1 Silent rs8187903 9 75551878 [T/C] NM_000689 ALDH1A1 Silent rs186997 9 75551910 [T/C] NM_000689 ALDH1A1 Silent rs8187902 9 75551996 [T/C] NM_000689 ALDH1A1 Silent rs2210103 9 75552133 [A/G] NM_000689 ALDH1A1 Silent rs8187901 9 75552391 [T/C] NM_000689 ALDH1A1 Silent rs8187900 9 75552472 [A/C] NM_000689 ALDH1A1 Silent rs348455 9 75552899 [A/G] NM_000689 ALDH1A1 Silent rs1330286 9 75552953 [G/C] NM_000689 ALDH1A1 Silent rs348454 9 75553212 [A/G] NM_000689 ALDH1A1 Silent rs348450 9 75554224 [T/C] NM_000689 ALDH1A1 Silent rs7027604 9 75554952 [A/C] NM_000689 ALDH1A1 Silent rs348449 9 75554982 [A/G] NM_000689 ALDH1A1 Silent rs8187896 9 75555531 [T/C] NM_000689 ALDH1A1 Silent rs8187895 9 75556909 [A/G] NM_000689 ALDH1A1 Silent rs1469167 9 75557007 [T/C] NM_000689 ALDH1A1 Silent rs1330285 9 75557728 [A/G] NM_000689 ALDH1A1 Silent rs8187894 9 75558766 [T/C] NM_000689 ALDH1A1 Silent rs8187893 9 75558799 [T/C] NM_000689 ALDH1A1 Silent rs2309779 9 75559038 [G/C] NM_000689 ALDH1A1 Silent rs647880 9 75559818 [T/C] NM_000689 ALDH1A1 Silent rs8187890 9 75559849 [T/C] NM_000689 ALDH1A1 Silent rs8187889 9 75560001 [A/G] NM_000689 ALDH1A1 Silent rs12000418 9 75560677 [T/C] NM_000689 ALDH1A1 Silent rs1928848 9 75561149 [A/G] NM_000689 ALDH1A1 Silent rs8187884 9 75561786 [A/C] NM_000689 ALDH1A1 Silent rs8187882 9 75562021 [T/G] NM_000689 ALDH1A1 Silent rs12684937 9 75562401 [A/G] NM_000689 ALDH1A1 Silent rs1424482 9 75563557 [T/C] NM_000689 ALDH1A1 Silent rs8187876 9 75564954 [T/C] NM_000689 ALDH1A1 Silent rs4567103 9 75565006 [T/A] NM_000689 ALDH1A1 Silent rs8187875 9 75565350 [T/C] NM_000689 ALDH1A1 Silent rs8187874 9 75565492 [A/C] NM_000689 ALDH1A1 Silent rs8187873 9 75565508 [T/C] NM_000689 ALDH1A1 Silent rs8187872 9 75565926 [T/C] NM_000689 ALDH1A1 Silent rs8187871 9 75565990 [T/C] NM_000689 ALDH1A1 Silent rs8187869 9 75566364 [T/C] NM_000689 ALDH1A1 Silent rs4646539 9 75567287 [A/G] NM_000689 ALDH1A1 Silent rs348445 9 75568803 [A/G] rs8187865 9 75569366 [A/G] rs8187864 9 75569482 [A/G] rs694564 9 75572106 [T/C] rs1330284 9 75576214 [A/G] rs7030453 9 75590794 [A/G] rs1364454 9 75593837 [A/G] rs7858367 9 75594556 [T/G] rs7849271 9 75597830 [A/G] rs7856728 9 75602903 [A/G] rs10869208 9 75608626 [T/C] rs1582620 9 75615188 [T/C] rs1424484 9 75624687 [A/G] rs1593197 9 75633424 [T/G] rs7028573 9 75636267 [A/G] rs2226111 9 75637712 [T/G] rs4745209 9 75640105 [T/C] rs11143438 9 75649046 [A/G] rs1418182 9 75663004 [T/C] rs17058377 9 75669183 [T/C] rs11143450 9 75669943 [A/G] rs10869215 9 75675129 [A/G] rs12348634 9 75694366 [T/C] rs7046288 9 75703530 [T/C] rs2153769 9 75706106 [T/C] rs2871480 9 75710330 [A/C] rs4744679 9 75715402 [A/C] rs1342020 9 75719701 [A/G] rs2039979 9 75720079 [T/G] rs2310329 9 75721449 [A/G] rs4744681 9 75721599 [T/C] rs1935314 9 75729671 [T/C] rs17058479 9 75730317 [A/G] rs7875996 9 75730662 [A/G] rs1935316 9 75732302 [T/C] rs11143481 9 75735898 [T/C] rs4745216 9 75744157 [A/C] rs11143486 9 75744524 [T/C] rs11788407 9 75745448 [T/C] rs12345770 9 75747374 [T/C] rs10869227 9 75757209 [T/C] rs11143503 9 75761043 [T/C] rs2795107 9 75763159 [T/C] rs2795108 9 75765478 [T/C] rs2795116 9 75773161 [A/G] NM_000700 ANXA1 Silent rs12000840 9 75774574 [T/G] NM_000700 ANXA1 Silent rs2795118 9 75778370 [A/G] NM_000700 ANXA1 Silent rs1342018 9 75782131 [A/G] NM_000700 ANXA1 Silent rs1342017 9 75782510 [A/G] NM_000700 ANXA1 Silent rs2811226 9 75784264 [A/G] NM_000700 ANXA1 Silent rs4745219 9 75788656 [T/C] rs7357731 9 75789935 [A/G] rs10781126 9 75792301 [A/G] rs11143520 9 75792846 [A/G] rs17058589 9 75793444 [T/C] rs4256646 9 75797835 [A/G] rs10869237 9 75800805 [T/C] rs4581120 9 75810204 [T/C] rs10746916 9 75810296 [A/G] rs4581121 9 75810393 [T/C] rs7848091 9 75813393 [T/C] rs17653504 9 75816850 [T/C] rs10869241 9 75817746 [T/C] rs7034411 9 75819224 [T/C] rs13290663 9 75819755 [T/C] rs10746917 9 75819945 [A/G] rs11143537 9 75820728 [A/G] rs12002154 9 75821365 [A/G] rs12005995 9 75824531 [A/G] rs10735621 9 75828161 [A/G] rs11143541 9 75837087 [T/G] rs9657736 9 75840034 [A/G] rs17058651 9 75858136 [T/C] rs10429583 9 75866968 [T/C] rs12001114 9 75872324 [A/G] rs7018507 9 75877116 [A/G] rs17058682 9 75895599 [A/G] rs7860450 9 75897972 [A/G] rs12343428 9 75900508 [A/G] rs10781135 9 75905148 [T/C] rs6560328 9 75906409 [A/G] rs12346494 9 75917152 [A/C] rs17058729 9 75921571 [T/G] rs1414158 9 75922132 [T/C] rs17058735 9 75922205 [T/C] rs10465189 9 75932178 [A/G] rs17058741 9 75936857 [A/G] rs954227 9 75956329 [T/C] rs1932202 9 75970379 [T/C] rs1414165 9 75975477 [T/C] rs7863241 9 75978400 [T/G] rs11143574 9 75979673 [A/G] rs1932201 9 75987179 [T/C] rs10735622 9 75991893 [A/G] rs10114105 9 76002121 [T/C] rs1335385 9 76017507 [T/C] rs17058849 9 76038127 [A/G] rs11143592 9 76045309 [T/C] rs280563 9 76054140 [T/C] rs1908811 9 76078682 [A/G] rs278747 9 76089602 [A/G] rs278738 9 76098252 [A/C] rs278736 9 76105546 [T/C] rs12115369 9 76107080 [T/G] rs7869926 9 76110354 [A/G] rs11143600 9 76115057 [T/C] rs11794852 9 76118698 [A/G] rs182183 9 76121101 [T/C] rs1390947 9 76125591 [A/C] rs993350 9 76126194 [T/C] rs407979 9 76150496 [A/G] rs10781146 9 76152918 [T/C] rs395937 9 76155313 [A/G] rs11789773 9 76157130 [A/C] rs12552642 9 76157987 [T/C] rs278717 9 76159447 [T/C] rs278727 9 76161901 [A/G] rs278729 9 76161967 [A/G] rs452974 9 76164687 [A/C] rs275528 9 76175652 [T/C] rs157117 9 76184436 [A/G] rs12339193 9 76185813 [T/C] rs17659570 9 76187476 [A/G] rs17059048 9 76188256 [A/C] rs10512023 9 76189863 [T/C] rs10512024 9 76191829 [A/G] rs157109 9 76198452 [T/G] rs2492825 9 76203946 [A/G] rs10217425 9 76204270 [T/C] rs275515 9 76204511 [A/G] rs7870301 9 76205632 [T/C] rs9314809 9 76207300 [A/G] rs1948203 9 76223251 [T/C] rs1505518 9 76224560 [A/G] rs17660640 9 76228755 [A/G] rs10512026 9 76228813 [T/G] rs7857209 9 76231486 [T/C] rs156762 9 76232053 [T/C] rs276781 9 76237760 [T/C] rs1398307 9 76242155 [T/C] rs156768 9 76246287 [A/G] rs1606326 9 76246845 [T/G] rs156772 9 76249347 [T/C] rs7850741 9 76253327 [A/G] rs1505517 9 76255260 [T/G] rs1352514 9 76256736 [A/C] rs2502788 9 76258721 [A/G] rs2490201 9 76292139 [A/C] rs11143650 9 76294389 [T/G] rs12350509 9 76295599 [T/C] rs11143657 9 76300013 [A/C] rs12352528 9 76301643 [T/C] rs11143663 9 76313134 [A/G] rs11143667 9 76321504 [A/G] rs1938287 9 76321671 [T/C] rs17059293 9 76325130 [A/G] rs13288902 9 76334135 [A/G] rs2171659 9 76343174 [T/C] rs12345517 9 76344038 [A/G] rs12003936 9 76350903 [T/G] rs1387289 9 76353087 [A/G] rs17605754 9 76355713 [A/G] rs1116198 9 76364970 [T/C] rs7466235 9 76366889 [A/C] rs11999541 9 76370298 [T/C] rs10869280 9 76371678 [A/G] rs1350503 9 76372107 [T/G] rs2007888 9 76375693 [A/G] rs7865076 9 76379534 [A/G] rs10869282 9 76381922 [T/C] rs2061398 9 76385522 [T/C] rs2125391 9 76389514 [A/G] rs4745257 9 76392885 [A/C] rs12352620 9 76397650 [T/C] rs1458490 9 76412152 [T/C] rs1458495 9 76427979 [A/C] rs17607547 9 76433395 [T/C] rs11999227 9 76433950 [T/C] rs12156550 9 76444334 [T/G] rs17059475 9 76446415 [A/G] rs4745262 9 76448339 [A/G] rs10869292 9 76480444 [T/C] rs898048 9 76510172 [T/C] rs1379907 9 76517066 [T/C] rs17059634 9 76539678 [A/G] rs7024811 9 76559485 [A/G] rs10869299 9 76560279 [T/C] rs10781171 9 76565484 [A/C] rs2029574 9 76576244 [T/C] rs12341498 9 76589084 [A/C] rs1491457 9 76596401 [A/G] rs11143754 9 76622068 [A/C] rs726900 9 76638581 [T/G] rs11143764 9 76648938 [T/C] rs12003009 9 76657755 [T/C] rs3012803 9 76659915 [T/C] rs2046913 9 76669299 [T/G] rs1032366 9 76670504 [T/C] rs10114881 9 76676071 [T/C] rs3012844 9 76679339 [T/C] rs3012830 9 76700000 [T/C] rs7020553 9 76710284 [A/C] rs4425827 9 76726435 [A/G] rs12238881 9 76727344 [A/G] rs12551119 9 76731402 [A/G] rs4745283 9 76732506 [A/G] rs10781187 9 76732765 [A/C] rs4288440 9 76740830 [A/G] rs4745285 9 76741048 [A/G] rs4745286 9 76741242 [T/C] rs7847369 9 76743899 [T/G] rs10869330 9 76744909 [A/C] rs11143804 9 76753271 [T/G] rs10781189 9 76755616 [T/C] rs4483218 9 76758064 [T/C] rs11143810 9 76764649 [A/G] rs10781190 9 76765949 [T/C] rs11143814 9 76766914 [T/C] rs12553320 9 76767313 [T/C] rs9314820 9 76775785 [T/G] rs10746936 9 76786297 [T/C] rs966266 9 76787591 [A/G] rs2045191 9 76793127 [T/C] rs10746938 9 76795159 [T/C] rs4543604 9 76810697 [T/C] rs4745304 9 76845371 [A/G] rs11143866 9 76853728 [T/C] rs17611237 9 76861089 [T/C] rs2889274 9 76872628 [T/C] rs13286134 9 76880794 [A/G] rs670010 9 76881401 [A/G] rs7022880 9 76886080 [T/C] rs2604271 9 76891412 [T/C] rs11143894 9 76905350 [A/C] rs11143896 9 76909190 [A/G] rs11143904 9 76916282 [A/C] rs10746953 9 76917840 [T/C] rs11143908 9 76921043 [T/C] rs11143913 9 76924650 [A/C] rs10869386 9 76926329 [T/C] rs11143917 9 76935726 [A/G] rs3925038 9 76936512 [T/C] rs2991751 9 76936998 [T/C] rs2991753 9 76938649 [T/C] rs11143921 9 76939127 [T/C] rs4237265 9 76944002 [T/C] rs12002539 9 76944989 [T/C] rs10491923 9 76949180 [T/C] rs7034999 9 76951346 [A/C] rs7040408 9 76955137 [T/C] rs1953287 9 76956283 [A/G] rs4255204 9 76960254 [A/G] rs7863592 9 76960437 [A/G] rs17060189 9 76962240 [T/C] rs11143935 9 76966194 [T/C] rs11143937 9 76967832 [T/C] rs17060197 9 76969241 [A/G] rs17277553 9 76970791 [T/C] rs3903098 9 76974920 [A/G] rs17060208 9 76976022 [T/C] rs11143944 9 76980484 [A/G] rs11143948 9 76994882 [T/C] NR_121182 LOC101927358 Silent rs11792875 9 77004242 [A/G] rs11143958 9 77010681 [A/G] rs4554546 9 77023144 [A/G] rs10869398 9 77034979 [A/G] rs17060276 9 77038959 [A/G] rs915291 9 77051764 [T/C] rs10125552 9 77097516 [T/C] NR_125791 RORB-AS1 Silent rs10869406 9 77114274 [A/G] NM_006914 RORB Silent rs13291991 9 77136979 [A/G] NM_006914 RORB Silent rs1018584 9 77138246 [A/C] NM_006914 RORB Silent rs10869412 9 77140951 [T/C] NM_006914 RORB Silent rs7870498 9 77146468 [A/G] NM_006914 RORB Silent rs7042950 9 77149837 [A/G] NM_006914 RORB Silent rs1323370 9 77157976 [A/C] NM_006914 RORB Silent rs17611535 9 77158236 [T/C] NM_006914 RORB Silent rs10217594 9 77159265 [T/C] NM_006914 RORB Silent rs10781235 9 77159715 [T/C] NM_006914 RORB Silent rs4745340 9 77164006 [A/C] NM_006914 RORB Silent rs17060345 9 77167502 [T/C] NM_006914 RORB Silent rs17612183 9 77187780 [T/C] NM_006914 RORB Silent rs17612218 9 77188885 [A/G] NM_006914 RORB Silent rs1323354 9 77192841 [T/C] NM_006914 RORB Silent rs10512036 9 77194528 [A/G] NM_006914 RORB Silent rs10781238 9 77194612 [T/C] NM_006914 RORB Silent rs1359073 9 77199157 [T/C] NM_006914 RORB Silent rs4744720 9 77206232 [A/G] NM_006914 RORB Silent rs7875098 9 77207987 [A/G] NM_006914 RORB Silent rs6560402 9 77216897 [T/C] NM_006914 RORB Silent rs11144020 9 77218345 [A/C] NM_006914 RORB Silent rs1323364 9 77222828 [A/G] NM_006914 RORB Silent rs10869428 9 77224088 [T/C] NM_006914 RORB Silent rs17613014 9 77224424 [T/C] NM_006914 RORB Silent rs10119947 9 77229161 [A/G] NM_006914 RORB Silent rs17691363 9 77232494 [A/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs10869430 9 77236263 [A/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs10869431 9 77238103 [A/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs1831121 9 77241777 [T/C] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs17691614 9 77245873 [A/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs7032677 9 77247597 [A/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs11144032 9 77254334 [A/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs2273975 9 77257346 [A/G] NM_006914,NM_001365023 RORB,RORB EXON Synonymous_R84R,Synonymous_R95R rs11144033 9 77258265 [A/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs1318794 9 77264428 [T/C] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs1319551 9 77264546 [T/C] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs12352112 9 77267620 [T/C] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs10869433 9 77268666 [T/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs11144039 9 77269060 [T/C] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs17060398 9 77272296 [A/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs7865407 9 77275913 [T/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs12001830 9 77279806 [T/C] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs10121918 9 77280145 [A/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs11144051 9 77282470 [A/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs1327837 9 77283889 [A/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs1323368 9 77288320 [A/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs1327836 9 77292289 [T/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs7027406 9 77298117 [T/C] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs17060408 9 77299044 [T/C] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs11144062 9 77299740 [A/G] NM_006914,NM_001365023 RORB,RORB Silent,Silent rs1410227 9 77305480 [A/G] NM_001365023 RORB EXON Silent rs1410226 9 77305695 [A/C] NM_001365023 RORB EXON Silent rs1410225 9 77308710 [A/G] rs499922 9 77312690 [T/C] rs525065 9 77313531 [A/C] rs577787 9 77315134 [T/C] rs1327834 9 77318073 [A/C] rs519067 9 77323772 [T/G] rs2245644 9 77324251 [T/C] rs11144073 9 77329367 [T/C] rs546542 9 77332549 [T/C] rs1536613 9 77332745 [A/G] rs2209820 9 77333181 [A/G] rs1327831 9 77336810 [T/C] rs11144075 9 77339291 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 EXON Silent,Silent,Silent rs1759831 9 77349845 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs35804026 9 77352340 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs7872289 9 77354944 [T/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs877809 9 77357968 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs2254229 9 77358430 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs500102 9 77358745 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs476673 9 77361384 [A/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs11787707 9 77366199 [A/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs12002738 9 77373129 [A/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs2274925 9 77376633 [A/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 EXON Synonymous_N1583N,Synonymous_N1583N,Synonymous_N1588N rs2274924 9 77376647 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 EXON Missense_K1579E,Missense_K1579E,Missense_K1584E rs3750425 9 77377410 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 EXON Missense_V1388I,Missense_V1388I,Missense_V1393I rs11144082 9 77393689 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs6560408 9 77396655 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs13290391 9 77400865 [T/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 EXON Missense_F943L,Missense_F943L,Missense_F948L rs11144083 9 77403203 [A/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs11144085 9 77404435 [A/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs2151424 9 77406281 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs4145894 9 77407636 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 EXON Synonymous_Q809Q,Synonymous_Q809Q,Synonymous_Q814Q rs7859201 9 77415284 [A/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 EXON Synonymous_L703L,Synonymous_L703L,Synonymous_L708L rs11144089 9 77416972 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 EXON Synonymous_L612L,Synonymous_L612L,Synonymous_L617L rs7848706 9 77417489 [A/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs17060535 9 77423730 [A/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs12551151 9 77424957 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs4745361 9 77441137 [T/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs7045949 9 77442616 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs17060568 9 77443424 [A/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs7852719 9 77445250 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs7867868 9 77446874 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs12343109 9 77450937 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs1475717 9 77454140 [T/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs12378991 9 77472066 [A/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs6560417 9 77475588 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs2184118 9 77476386 [A/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs9650770 9 77486459 [A/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs7858012 9 77494156 [T/C] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 Silent,Silent,Silent rs1333342 9 77502160 [A/G] NM_001177310,NM_001177311,NM_017662 TRPM6,TRPM6,TRPM6 EXON Silent,Missense_T2I,Silent rs1333343 9 77502322 [T/C] NM_001177310,NM_017662 TRPM6,TRPM6 Silent,Silent rs17060609 9 77513590 [T/C] rs11144144 9 77516005 [A/G] rs2800249 9 77516923 [A/G] rs13298337 9 77520324 [T/C] rs2800265 9 77520677 [A/G] rs2769064 9 77523690 [T/C] rs2769050 9 77530589 [T/C] rs1176828 9 77534116 [T/C] rs7029929 9 77535512 [A/G] rs13299921 9 77535672 [T/C] rs1359879 9 77536753 [T/C] rs4745367 9 77543548 [T/C] rs10118224 9 77545238 [T/C] rs7045757 9 77551462 [T/C] rs1176816 9 77551617 [A/G] rs11144166 9 77561136 [A/C] rs2769058 9 77563087 [T/C] NM_017998 C9orf40 EXON Synonymous_Q154Q rs10869460 9 77573159 [T/G] NR_121183 C9orf41-AS1 Silent rs7867200 9 77585644 [A/G] NR_121183 C9orf41-AS1 Silent rs11144177 9 77595402 [T/G] NR_121183 C9orf41-AS1 Silent rs13340643 9 77595948 [A/T] NR_121183,NR_135282,NM_152420,NM_001320497 C9orf41-AS1,CARNMT1,CARNMT1,CARNMT1 EXON Silent,Silent,Silent,Silent rs10869464 9 77597362 [A/C] NR_121183,NR_135282,NM_152420,NM_001320497 C9orf41-AS1,CARNMT1,CARNMT1,CARNMT1 EXON Silent,Silent,Silent,Silent rs1779988 9 77598195 [A/G] NR_121183,NR_135282,NM_152420,NM_001320497 C9orf41-AS1,CARNMT1,CARNMT1,CARNMT1 EXON Silent,Silent,Silent,Silent rs11144179 9 77608145 [A/G] NR_121183,NR_135282,NM_152420,NM_001320497 C9orf41-AS1,CARNMT1,CARNMT1,CARNMT1 Silent,Silent,Silent,Silent rs10781258 9 77618438 [A/C] NR_135282,NM_152420,NM_001320497 CARNMT1,CARNMT1,CARNMT1 Silent,Silent,Silent rs11144184 9 77624761 [T/C] NR_135282,NM_152420,NM_001320497 CARNMT1,CARNMT1,CARNMT1 Silent,Silent,Silent rs10869474 9 77641451 [A/C] NR_135282,NM_152420,NM_001320497 CARNMT1,CARNMT1,CARNMT1 Silent,Silent,Silent rs10781262 9 77650696 [A/G] rs10869476 9 77652455 [A/G] rs7850614 9 77653755 [A/C] rs773139 9 77662999 [A/G] rs11144203 9 77670081 [T/C] rs11144207 9 77675778 [A/C] NM_001330679,NM_001330678 NMRK1,NMRK1 EXON Silent,Silent rs11519 9 77676285 [T/G] NM_001330679,NM_001330678,NM_001127603,NM_017881 NMRK1,NMRK1,NMRK1,NMRK1 EXON Silent,Silent,Silent,Silent rs3780175 9 77682437 [T/C] NM_001330679,NM_001330678,NM_001127603,NM_017881 NMRK1,NMRK1,NMRK1,NMRK1 Silent,Silent,Silent,Silent rs7021664 9 77683026 [T/C] NM_001330679,NM_001330678,NM_001127603,NM_017881 NMRK1,NMRK1,NMRK1,NMRK1 Silent,Silent,Silent,Silent rs7021926 9 77683225 [T/C] NM_001330679,NM_001330678,NM_001127603,NM_017881 NMRK1,NMRK1,NMRK1,NMRK1 Silent,Silent,Silent,Silent rs13289688 9 77684439 [A/G] NM_001330679,NM_001330678,NM_001127603,NM_017881 NMRK1,NMRK1,NMRK1,NMRK1 Silent,Silent,Silent,Silent rs3752955 9 77684690 [A/C] NM_001330679,NM_001330678,NM_001127603,NM_017881 NMRK1,NMRK1,NMRK1,NMRK1 EXON Synonymous_T123T,Synonymous_T123T,Silent,Synonymous_T119T rs7857408 9 77690463 [T/C] NM_001330679,NM_001330678,NM_001127603,NM_017881 NMRK1,NMRK1,NMRK1,NMRK1 Silent,Silent,Silent,Silent rs2376397 9 77690749 [T/C] NM_001330679,NM_001330678,NM_001127603,NM_017881 NMRK1,NMRK1,NMRK1,NMRK1 Silent,Silent,Silent,Silent rs4442208 9 77693316 [T/C] NM_001330679,NM_001330678,NM_001127603,NM_017881 NMRK1,NMRK1,NMRK1,NMRK1 EXON Silent,Silent,Silent,Silent rs11144217 9 77696677 [T/C] NM_001330679,NM_001330678,NM_001127603,NM_017881 NMRK1,NMRK1,NMRK1,NMRK1 Silent,Silent,Silent,Silent rs11144218 9 77696918 [T/C] NM_001330679,NM_001330678,NM_001127603,NM_017881 NMRK1,NMRK1,NMRK1,NMRK1 Silent,Silent,Silent,Silent rs2273765 9 77697526 [A/C] NM_001330679,NM_001330678,NM_001127603,NM_017881 NMRK1,NMRK1,NMRK1,NMRK1 Silent,Silent,Silent,Silent rs10869495 9 77699899 [T/C] NM_001330679,NM_001330678,NM_001127603,NM_017881 NMRK1,NMRK1,NMRK1,NMRK1 Silent,Silent,Silent,Silent rs10869496 9 77700084 [A/C] NM_001330679,NM_001330678,NM_001127603,NM_017881 NMRK1,NMRK1,NMRK1,NMRK1 Silent,Silent,Silent,Silent rs10869497 9 77705570 [T/C] NM_012383 OSTF1 Silent rs2376398 9 77706944 [T/C] NM_012383 OSTF1 Silent rs7042557 9 77708218 [T/C] NM_012383 OSTF1 Silent rs10123421 9 77713279 [A/G] NM_012383 OSTF1 Silent rs11144228 9 77716145 [T/C] NM_012383 OSTF1 Silent rs1033777 9 77722267 [T/C] NM_012383 OSTF1 Silent rs7848243 9 77725030 [T/C] NM_012383 OSTF1 Silent rs10869504 9 77726636 [A/G] NM_012383 OSTF1 Silent rs3780180 9 77727884 [T/C] NM_012383 OSTF1 Silent rs10869507 9 77737029 [A/G] NM_012383 OSTF1 Silent rs6560421 9 77744416 [A/G] NM_012383 OSTF1 Silent rs2295861 9 77745424 [T/C] NM_012383 OSTF1 Silent rs2295862 9 77745504 [A/G] NM_012383 OSTF1 EXON Missense_N48S rs7040349 9 77748151 [A/G] NM_012383 OSTF1 Silent rs7872448 9 77748968 [T/C] NM_012383 OSTF1 Silent rs10869509 9 77749569 [T/C] NM_012383 OSTF1 Silent rs11144246 9 77750789 [A/G] NM_012383 OSTF1 Silent rs1009282 9 77752967 [A/G] NM_012383 OSTF1 Silent rs2273770 9 77755469 [T/C] NM_012383 OSTF1 Silent rs7862075 9 77758636 [T/C] NM_012383 OSTF1 Silent rs4376557 9 77760543 [A/G] NM_012383 OSTF1 Silent rs2146044 9 77761642 [T/C] NM_012383 OSTF1 EXON Synonymous_D210D rs1407376 9 77762449 [A/G] rs13290703 9 77763300 [A/G] rs7041918 9 77763924 [A/G] rs17704078 9 77764011 [T/C] rs7859631 9 77767024 [A/G] rs10869516 9 77767571 [T/C] rs773024 9 77770054 [A/G] rs1081875 9 77780144 [T/C] rs1081877 9 77782517 [T/C] rs11144271 9 77785171 [T/C] rs10283463 9 77789607 [A/G] rs10283465 9 77789735 [T/G] rs12341208 9 77806643 [A/G] rs9775775 9 77807211 [A/G] rs17060946 9 77808519 [A/G] rs10781268 9 77809042 [A/C] rs7030420 9 77809075 [A/G] rs12348213 9 77809291 [A/G] rs10781269 9 77812173 [A/G] rs10283844 9 77813220 [T/C] rs1999462 9 77813584 [T/C] rs10781270 9 77813720 [A/G] rs10124785 9 77814984 [A/G] rs13294304 9 77817068 [A/G] rs1332349 9 77825733 [A/C] rs12550903 9 77830570 [T/C] rs1930069 9 77830922 [T/C] rs1332366 9 77832575 [A/G] rs1412461 9 77833663 [A/G] rs11559396 9 77835651 [T/C] rs6560430 9 77846356 [A/C] rs4629935 9 77848630 [A/G] rs4342676 9 77848711 [A/G] rs4614064 9 77848790 [T/C] rs7032088 9 77849725 [A/G] rs7852833 9 77851696 [T/C] rs11144325 9 77852292 [A/G] rs2095060 9 77852659 [A/G] rs2095057 9 77853236 [A/G] rs10869533 9 77854544 [A/C] rs10869534 9 77854711 [T/G] rs12000663 9 77857783 [T/C] rs1537295 9 77858306 [T/C] rs10119763 9 77858578 [T/G] rs7854525 9 77877793 [T/G] rs7037086 9 77881317 [A/G] rs10869542 9 77895520 [T/C] rs12340376 9 77898266 [T/C] rs7861441 9 77905427 [A/G] rs7028291 9 77933300 [T/C] rs4332197 9 77936388 [A/C] rs10115058 9 77965572 [T/C] rs2376734 9 77976700 [A/G] rs11144406 9 77988254 [A/G] rs11144407 9 77988304 [A/G] rs1409937 9 77991404 [A/G] rs12004565 9 77992822 [A/G] rs2094372 9 77996459 [T/G] rs12377787 9 77996819 [A/G] rs7867522 9 77999354 [T/G] rs10869554 9 78005255 [T/C] rs1327377 9 78012662 [T/G] rs10781285 9 78012950 [A/C] rs7019425 9 78019028 [T/G] rs7022486 9 78024439 [T/C] rs17712651 9 78027655 [A/G] rs489332 9 78028346 [T/C] rs569406 9 78029345 [T/C] rs1327378 9 78029927 [T/C] rs1327379 9 78030021 [T/C] rs477651 9 78032390 [A/G] rs1887375 9 78035226 [A/G] rs11144428 9 78038069 [T/C] rs473299 9 78042927 [A/G] rs551421 9 78045277 [A/G] rs7854515 9 78052850 [T/C] rs13287590 9 78056969 [A/G] rs17713515 9 78061074 [T/C] rs1327371 9 78064806 [A/G] rs891370 9 78066726 [A/G] rs13301187 9 78068052 [A/C] rs500859 9 78068102 [A/G] rs9314833 9 78068222 [T/C] rs578023 9 78069403 [T/G] rs516609 9 78069679 [T/C] rs2078096 9 78070574 [A/G] rs10123838 9 78071910 [T/C] rs1359806 9 78080515 [A/G] rs4744750 9 78084508 [T/C] rs2009306 9 78085490 [T/C] rs524346 9 78089813 [A/G] rs11144436 9 78091442 [A/G] rs477986 9 78091722 [T/C] rs7042130 9 78092155 [T/G] rs7028332 9 78092361 [A/G] rs969312 9 78096565 [A/G] rs522560 9 78099292 [A/G] rs1327369 9 78108869 [A/G] rs529872 9 78111609 [T/C] rs2778899 9 78113669 [T/G] rs12551990 9 78113689 [A/G] rs549347 9 78118063 [A/G] rs10512042 9 78119359 [A/G] NR_031679 MIR548H3 Silent rs10512043 9 78120328 [T/G] NR_031679 MIR548H3 Silent rs576367 9 78123330 [A/C] NR_031679 MIR548H3 Silent rs1591079 9 78126270 [T/C] NR_031679 MIR548H3 Silent rs12156469 9 78127980 [T/C] NR_031679 MIR548H3 Silent rs928423 9 78141623 [T/C] NR_031679 MIR548H3 Silent rs1332518 9 78143128 [A/G] NR_031679 MIR548H3 Silent rs12000133 9 78144832 [T/G] NR_031679 MIR548H3 Silent rs12002365 9 78146907 [T/C] NR_031679 MIR548H3 Silent rs4745416 9 78147051 [T/C] NR_031679 MIR548H3 Silent rs10512045 9 78155439 [A/C] NR_031679 MIR548H3 Silent rs10781292 9 78157110 [T/C] NR_031679 MIR548H3 Silent rs11144480 9 78158285 [A/G] NR_031679 MIR548H3 Silent rs1010568 9 78158939 [T/G] NR_031679 MIR548H3 Silent rs10116662 9 78163305 [T/C] NR_031679 MIR548H3 Silent rs4451372 9 78165213 [T/G] NR_031679 MIR548H3 Silent rs10869587 9 78171186 [T/C] NR_031679 MIR548H3 Silent rs10435971 9 78183488 [A/G] NR_031679 MIR548H3 Silent rs12340637 9 78185039 [A/G] NR_031679 MIR548H3 Silent rs10869590 9 78191069 [A/G] NR_031679 MIR548H3 Silent rs7872039 9 78193142 [A/G] NR_031679 MIR548H3 Silent rs10869593 9 78206328 [T/C] NR_031679 MIR548H3 Silent rs7045152 9 78206459 [T/C] NR_031679 MIR548H3 Silent rs11144502 9 78207219 [A/G] NR_031679 MIR548H3 Silent rs7019700 9 78208290 [A/G] NR_031679 MIR548H3 Silent rs7864568 9 78212428 [A/G] NR_031679 MIR548H3 Silent rs10118286 9 78212566 [A/G] NR_031679 MIR548H3 Silent rs11144509 9 78215299 [A/G] NR_031679 MIR548H3 Silent rs10114227 9 78215586 [T/C] NR_031679 MIR548H3 Silent rs11144511 9 78218231 [T/C] NR_031679 MIR548H3 Silent rs11144513 9 78221432 [T/C] NR_031679 MIR548H3 Silent rs13300641 9 78222406 [T/C] NR_031679 MIR548H3 Silent rs12683806 9 78223506 [T/C] NR_031679 MIR548H3 Silent rs1328556 9 78224432 [T/C] NR_031679 MIR548H3 Silent rs11144516 9 78228430 [A/C] NR_031679 MIR548H3 Silent rs914660 9 78230339 [A/G] NR_031679 MIR548H3 Silent rs10869601 9 78230797 [T/C] NR_031679 MIR548H3 Silent rs11144526 9 78239754 [A/G] NR_031679 MIR548H3 Silent rs13290264 9 78240443 [A/G] NR_031679 MIR548H3 Silent rs7026536 9 78243639 [T/C] NR_031679 MIR548H3 Silent rs10869608 9 78243859 [T/C] NR_031679 MIR548H3 Silent rs11144540 9 78249553 [A/G] NR_031679 MIR548H3 Silent rs17645740 9 78250722 [A/C] NR_031679 MIR548H3 Silent rs1328570 9 78251232 [T/C] NR_031679 MIR548H3 Silent rs1328569 9 78251528 [T/C] NR_031679 MIR548H3 Silent rs11144543 9 78259163 [T/C] NR_031679 MIR548H3 Silent rs7030860 9 78259536 [T/C] NR_031679 MIR548H3 Silent rs7031657 9 78260121 [T/C] NR_031679 MIR548H3 Silent rs1359999 9 78260618 [T/C] NR_031679 MIR548H3 Silent rs943860 9 78260714 [A/G] NR_031679 MIR548H3 Silent rs6560465 9 78262577 [T/C] NR_031679 MIR548H3 Silent rs12344781 9 78263056 [T/C] NR_031679 MIR548H3 Silent rs2094583 9 78263400 [A/G] NR_031679 MIR548H3 Silent rs3939133 9 78263565 [T/C] NR_031679 MIR548H3 Silent rs1328565 9 78266575 [A/G] NR_031679 MIR548H3 Silent rs10869620 9 78267055 [T/C] NR_031679 MIR548H3 Silent rs7038116 9 78267078 [A/G] NR_031679 MIR548H3 Silent rs1887796 9 78267235 [A/C] NR_031679 MIR548H3 Silent rs9696683 9 78268985 [A/G] NR_031679 MIR548H3 Silent rs1927986 9 78271704 [A/G] NR_031679 MIR548H3 Silent rs4745430 9 78272025 [T/C] NR_031679 MIR548H3 Silent rs4745431 9 78272095 [T/C] NR_031679 MIR548H3 Silent rs4442209 9 78273456 [A/G] NR_031679 MIR548H3 Silent rs1014766 9 78274889 [A/G] NR_031679 MIR548H3 Silent rs11144561 9 78276017 [T/C] NR_031679 MIR548H3 Silent rs2094588 9 78277767 [T/C] NR_031679 MIR548H3 Silent rs7857624 9 78279942 [T/C] NR_031679 MIR548H3 Silent rs11144565 9 78282011 [T/C] NR_031679 MIR548H3 Silent rs1571413 9 78282779 [T/C] NR_031679 MIR548H3 Silent rs1571414 9 78282994 [A/G] NR_031679 MIR548H3 Silent rs943863 9 78283997 [T/C] NR_031679 MIR548H3 Silent rs11144566 9 78284116 [A/C] NR_031679 MIR548H3 Silent rs943864 9 78284173 [A/G] NR_031679 MIR548H3 Silent rs943865 9 78284451 [T/C] NR_031679 MIR548H3 Silent rs11144569 9 78286685 [A/C] NR_031679 MIR548H3 Silent rs1410579 9 78286736 [A/G] NR_031679 MIR548H3 Silent rs7026438 9 78289296 [A/G] NR_031679 MIR548H3 Silent rs7031238 9 78289935 [A/C] NR_031679 MIR548H3 Silent rs7866089 9 78291861 [T/G] NR_031679 MIR548H3 Silent rs10869631 9 78294845 [A/G] NR_031679 MIR548H3 Silent rs12001533 9 78296308 [T/G] NR_031679 MIR548H3 Silent rs7856004 9 78301522 [T/G] NR_031679 MIR548H3 Silent rs4745436 9 78302645 [A/G] NR_031679 MIR548H3 Silent rs1013792 9 78306320 [T/C] NR_031679 MIR548H3 Silent rs1328549 9 78306554 [T/G] NR_031679 MIR548H3 Silent rs1410569 9 78306600 [T/C] NR_031679 MIR548H3 Silent rs17061560 9 78307440 [A/G] NR_031679 MIR548H3 Silent rs4745437 9 78308057 [T/C] NR_031679 MIR548H3 Silent rs1359998 9 78308605 [T/C] NR_031679 MIR548H3 Silent rs7863282 9 78308750 [T/G] NR_031679 MIR548H3 Silent rs1328550 9 78309287 [T/C] NR_031679 MIR548H3 Silent rs10746980 9 78313509 [T/C] NR_031679 MIR548H3 Silent rs1328554 9 78313939 [A/C] NR_031679 MIR548H3 Silent rs7874982 9 78314854 [A/C] NR_031679 MIR548H3 Silent rs7044203 9 78315752 [T/C] NR_031679 MIR548H3 Silent rs518417 9 78322176 [T/G] NR_031679 MIR548H3 Silent rs693362 9 78325082 [A/G] NR_031679 MIR548H3 Silent rs2479837 9 78328761 [A/C] NR_031679 MIR548H3 Silent rs11144589 9 78330608 [A/C] NR_031679 MIR548H3 Silent rs17663620 9 78331051 [A/G] NR_031679 MIR548H3 Silent rs795085 9 78331204 [A/C] NR_031679 MIR548H3 Silent rs473295 9 78331945 [A/G] NR_031679 MIR548H3 Silent rs4744765 9 78332861 [T/G] NR_031679 MIR548H3 Silent rs2986388 9 78332998 [T/C] NR_031679 MIR548H3 Silent rs4744766 9 78333017 [A/G] NR_031679 MIR548H3 Silent rs489571 9 78333685 [T/C] NR_031679 MIR548H3 Silent rs17061627 9 78336697 [T/C] NR_031679 MIR548H3 Silent rs2149385 9 78339768 [T/C] rs487502 9 78342898 [T/C] rs7038479 9 78345727 [A/G] rs2479843 9 78347251 [T/G] rs10869637 9 78348570 [T/C] rs7025497 9 78350057 [A/G] rs561412 9 78350484 [A/G] rs11144603 9 78351260 [A/C] rs1359715 9 78354076 [T/C] rs1328560 9 78355920 [A/G] rs7043104 9 78356438 [A/G] rs7041935 9 78368000 [T/C] rs1751250 9 78369830 [A/G] rs1753320 9 78369864 [T/C] rs1753321 9 78369986 [T/G] rs528408 9 78371410 [A/C] rs7860318 9 78372907 [T/C] rs1926728 9 78391161 [A/G] rs1359716 9 78397226 [T/C] rs4745444 9 78407484 [T/C] rs1409689 9 78412423 [A/C] rs7856261 9 78416165 [A/G] rs10869646 9 78416519 [A/C] rs11144624 9 78416549 [A/G] rs11144627 9 78425373 [A/G] rs12344488 9 78425925 [A/G] rs9918954 9 78428857 [T/C] rs2025767 9 78430918 [T/C] rs1326914 9 78438434 [T/C] rs11793539 9 78439746 [A/G] rs6560469 9 78450924 [A/G] rs4745450 9 78452816 [T/C] rs10869656 9 78454330 [T/C] rs7027513 9 78456306 [A/G] rs10869657 9 78458130 [A/G] rs1831037 9 78458935 [T/C] rs2148588 9 78465639 [T/C] rs7030848 9 78473260 [A/G] rs10125361 9 78474999 [T/C] rs11144655 9 78479072 [T/G] rs1326904 9 78479975 [T/C] rs1934737 9 78485374 [A/G] rs1934735 9 78485754 [T/C] rs1544181 9 78489484 [A/G] rs7866449 9 78495438 [T/C] rs10869664 9 78496742 [T/G] rs12156495 9 78497134 [A/G] rs7862766 9 78497266 [T/G] rs2377423 9 78502734 [T/C] rs12336209 9 78504196 [A/G] rs3814115 9 78504729 [T/C] rs7040769 9 78506187 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 EXON Synonymous_C30C,Silent,Synonymous_C30C rs2050833 9 78509414 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs7027130 9 78510036 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs7031971 9 78511363 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs4745464 9 78512019 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs4744774 9 78515871 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs4744775 9 78518859 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869665 9 78518999 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1006279 9 78527549 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1006280 9 78529571 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs12115679 9 78529986 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs4554552 9 78536089 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10512051 9 78536862 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2377426 9 78546389 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10120870 9 78546411 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869666 9 78548556 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869667 9 78551222 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs11144690 9 78556095 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs4584211 9 78557137 [A/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869672 9 78562669 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs4504704 9 78567264 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs17061821 9 78570116 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2066188 9 78570960 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1340503 9 78571504 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs11144698 9 78573139 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs4745478 9 78575644 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1340510 9 78576644 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10781320 9 78579094 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10781321 9 78579268 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869673 9 78580233 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs914256 9 78581439 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10512052 9 78583187 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs11144702 9 78583414 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs11144705 9 78590288 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10781322 9 78590669 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2153496 9 78594609 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs7847011 9 78596109 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1340508 9 78598605 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs6560480 9 78599133 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2789610 9 78608872 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1416556 9 78613185 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs6560483 9 78615371 [T/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs12000040 9 78619829 [A/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2789607 9 78621536 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1416553 9 78622348 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs17061934 9 78626324 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1538505 9 78631286 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1339251 9 78636676 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10781324 9 78639196 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10781325 9 78640399 [T/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10781328 9 78641311 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs12342299 9 78642228 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs12554374 9 78642567 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs12350428 9 78643712 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs12686149 9 78647201 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs11144723 9 78649934 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869682 9 78651290 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10521467 9 78651491 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs7033416 9 78651988 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1029040 9 78653823 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1029037 9 78653976 [A/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1023181 9 78654101 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs6560488 9 78655927 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs6560490 9 78656338 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2777020 9 78657751 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs11144728 9 78659547 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2185230 9 78659798 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2153228 9 78663605 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs9886813 9 78664405 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs13291278 9 78670516 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1258094 9 78673593 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2153227 9 78683749 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869685 9 78684215 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2297344 9 78686818 [T/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs871449 9 78687998 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10512053 9 78688079 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1339254 9 78688289 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10781331 9 78689238 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1475615 9 78690471 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869688 9 78690813 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs7027736 9 78703073 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1029036 9 78705681 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1571792 9 78706282 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869692 9 78708179 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10781332 9 78713300 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs12001902 9 78715080 [T/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1416548 9 78718544 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869695 9 78718893 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1339230 9 78719646 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869696 9 78721540 [A/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs7860650 9 78721689 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2297343 9 78722328 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs4744780 9 78723048 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs914366 9 78723206 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs914365 9 78723307 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869699 9 78726242 [T/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1571790 9 78729176 [T/A] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1571791 9 78729213 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs7046252 9 78730136 [A/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1467773 9 78733068 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs990657 9 78738971 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10119550 9 78739959 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs11144756 9 78740235 [A/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs7037905 9 78741027 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1339236 9 78742125 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs7035578 9 78745177 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs6560502 9 78745460 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10746992 9 78746781 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs4745507 9 78751632 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1416552 9 78751683 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs13283154 9 78752764 [A/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1416325 9 78755492 [T/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs6560506 9 78757167 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869708 9 78757975 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1331384 9 78759288 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs9314838 9 78762118 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs4745511 9 78762295 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs4391491 9 78762796 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs17776673 9 78768830 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs883830 9 78770335 [A/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2377525 9 78772523 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs12236697 9 78773209 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2297342 9 78773953 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 EXON Synonymous_S495S,Silent,Synonymous_S495S rs1888705 9 78775570 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869713 9 78776057 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1411956 9 78777937 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs6560507 9 78779832 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869715 9 78780475 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs7037635 9 78780578 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1331386 9 78781260 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10124834 9 78785098 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs12353075 9 78786880 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869720 9 78788473 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs17062174 9 78788543 [A/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2377527 9 78791189 [T/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10781344 9 78791312 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs12684735 9 78792438 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs1571793 9 78793274 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2377528 9 78793895 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs7045212 9 78795051 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2270570 9 78796522 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs2279659 9 78800114 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs17062197 9 78800281 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869723 9 78800989 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs11144786 9 78801100 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs7872680 9 78802474 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs7046850 9 78803466 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10521468 9 78803512 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 EXON Synonymous_C767C,Silent,Synonymous_C767C rs10869726 9 78804704 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869727 9 78804842 [A/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 Silent,Silent,Silent rs10869729 9 78808493 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 EXON Silent,Silent,Silent rs11793906 9 78810203 [A/G] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 EXON Silent,Silent,Silent rs966097 9 78810344 [T/C] NM_001190482,NR_120409,NM_006200 PCSK5,PCSK5,PCSK5 EXON Silent,Silent,Silent rs10869730 9 78810887 [A/C] NM_001190482 PCSK5 Silent rs10869731 9 78811377 [T/C] NM_001190482 PCSK5 Silent rs7031594 9 78811935 [T/C] NM_001190482 PCSK5 Silent rs10746995 9 78815368 [T/C] NM_001190482 PCSK5 Silent rs7026021 9 78816016 [T/C] NM_001190482 PCSK5 Silent rs11144794 9 78816092 [A/G] NM_001190482 PCSK5 Silent rs12379097 9 78817288 [T/C] NM_001190482 PCSK5 Silent rs4745528 9 78820927 [A/G] NM_001190482 PCSK5 Silent rs990559 9 78823996 [T/G] NM_001190482 PCSK5 Silent rs1039034 9 78826932 [A/C] NM_001190482 PCSK5 Silent rs10781347 9 78834472 [T/C] NM_001190482 PCSK5 Silent rs10869736 9 78836985 [T/C] NM_001190482 PCSK5 Silent rs10781349 9 78843635 [T/C] NM_001190482 PCSK5 Silent rs1979737 9 78845010 [T/C] NM_001190482 PCSK5 Silent rs10869741 9 78849238 [A/G] NM_001190482 PCSK5 Silent rs1353343 9 78851588 [T/C] NM_001190482 PCSK5 Silent rs13293615 9 78852069 [T/G] NM_001190482 PCSK5 Silent rs2007744 9 78854312 [T/G] NM_001190482 PCSK5 Silent rs17720899 9 78856589 [T/C] NM_001190482 PCSK5 Silent rs1908495 9 78859359 [T/C] NM_001190482 PCSK5 Silent rs2261557 9 78863548 [T/C] NM_001190482 PCSK5 Silent rs1587103 9 78865300 [A/G] NM_001190482 PCSK5 Silent rs2643328 9 78867869 [T/C] NM_001190482 PCSK5 Silent rs10781353 9 78868816 [T/C] NM_001190482 PCSK5 Silent rs1002420 9 78869524 [A/C] NM_001190482 PCSK5 Silent rs2261722 9 78869581 [A/G] NM_001190482 PCSK5 Silent rs2842472 9 78872846 [A/G] NM_001190482 PCSK5 Silent rs1353342 9 78874769 [A/C] NM_001190482 PCSK5 Silent rs2643322 9 78885928 [A/G] NM_001190482 PCSK5 Silent rs2490588 9 78887992 [A/C] NM_001190482 PCSK5 Silent rs1994964 9 78888137 [A/G] NM_001190482 PCSK5 Silent rs10781356 9 78889021 [T/C] NM_001190482 PCSK5 Silent rs3915861 9 78892526 [A/G] NM_001190482 PCSK5 Silent rs1603199 9 78897735 [A/C] NM_001190482 PCSK5 Silent rs9314843 9 78899083 [A/C] NM_001190482 PCSK5 Silent rs10115735 9 78900161 [T/G] NM_001190482 PCSK5 Silent rs1495257 9 78901112 [T/C] NM_001190482 PCSK5 Silent rs2260411 9 78902949 [T/C] NM_001190482 PCSK5 Silent rs2842486 9 78903962 [T/C] NM_001190482 PCSK5 Silent rs903549 9 78904272 [A/G] NM_001190482 PCSK5 Silent rs903547 9 78904508 [A/C] NM_001190482 PCSK5 Silent rs17721076 9 78904950 [T/C] NM_001190482 PCSK5 Silent rs2842483 9 78906150 [A/G] NM_001190482 PCSK5 Silent rs7021909 9 78907594 [A/G] NM_001190482 PCSK5 Silent rs10115184 9 78907662 [A/C] NM_001190482 PCSK5 Silent rs2260649 9 78908826 [A/G] NM_001190482 PCSK5 Silent rs10869747 9 78910401 [A/G] NM_001190482 PCSK5 Silent rs7039902 9 78912008 [A/G] NM_001190482 PCSK5 Silent rs7025902 9 78912017 [A/G] NM_001190482 PCSK5 Silent rs2842478 9 78913563 [T/G] NM_001190482 PCSK5 Silent rs1078868 9 78915454 [A/G] NM_001190482 PCSK5 Silent rs11788518 9 78917378 [T/C] NM_001190482 PCSK5 Silent rs2490591 9 78919387 [T/G] NM_001190482 PCSK5 Silent rs6560511 9 78925282 [A/G] NM_001190482 PCSK5 Silent rs976825 9 78928591 [A/G] NM_001190482 PCSK5 Silent rs7022994 9 78929063 [A/C] NM_001190482 PCSK5 Silent rs2055164 9 78929086 [T/C] NM_001190482 PCSK5 Silent rs2258063 9 78930965 [A/G] NM_001190482 PCSK5 Silent rs2258131 9 78931893 [A/G] NM_001190482 PCSK5 Silent rs1027384 9 78932693 [A/G] NM_001190482 PCSK5 Silent rs11144827 9 78933874 [A/G] NM_001190482 PCSK5 Silent rs1110222 9 78936358 [A/G] NM_001190482 PCSK5 EXON Missense_G1275D rs11144829 9 78936564 [A/G] NM_001190482 PCSK5 Silent rs2842468 9 78937619 [T/C] NM_001190482 PCSK5 Silent rs2842467 9 78938628 [A/G] NM_001190482 PCSK5 Silent rs2803433 9 78940026 [A/G] NM_001190482 PCSK5 Silent rs2259969 9 78942956 [A/G] NM_001190482 PCSK5 EXON Synonymous_S1430S rs11144834 9 78947200 [A/G] NM_001190482 PCSK5 Silent rs7026762 9 78949109 [T/C] NM_001190482 PCSK5 Silent rs2803439 9 78950203 [A/G] NM_001190482 PCSK5 Silent rs1390143 9 78956690 [A/C] NM_001190482 PCSK5 Silent rs12003309 9 78957136 [A/G] NM_001190482 PCSK5 Silent rs10781357 9 78958599 [A/G] NM_001190482 PCSK5 Silent rs10869756 9 78959341 [T/C] NM_001190482 PCSK5 Silent rs2842495 9 78959679 [A/G] NM_001190482 PCSK5 Silent rs11144848 9 78961388 [A/G] NM_001190482 PCSK5 Silent rs13300668 9 78962285 [A/G] NM_001190482 PCSK5 Silent rs2803405 9 78962759 [T/C] NM_001190482 PCSK5 Silent rs2257220 9 78965993 [A/G] NM_001190482 PCSK5 Silent rs10869765 9 78971232 [A/G] NM_001190482 PCSK5 Silent rs7034265 9 78971253 [T/C] NM_001190482 PCSK5 Silent rs7850726 9 78973085 [A/G] NM_001190482 PCSK5 Silent rs2377637 9 78975569 [A/G] NM_001190482 PCSK5 EXON Silent rs13288756 9 78976710 [T/C] NM_001190482 PCSK5 EXON Silent rs17777982 9 78977268 [A/G] rs2490572 9 78987645 [T/G] rs2501936 9 78987999 [A/G] rs2490573 9 78989528 [A/G] rs2490574 9 78989956 [A/G] rs1961995 9 78993077 [T/C] rs7038009 9 78994056 [T/C] rs11144870 9 79004213 [T/C] NM_018339 RFK Silent rs2490582 9 79009106 [A/C] NM_018339 RFK EXON Silent rs6560514 9 79015381 [T/C] rs7035385 9 79019066 [T/C] rs2501920 9 79020386 [T/C] rs10869770 9 79032236 [T/C] rs7847608 9 79032427 [T/C] rs12216907 9 79036059 [A/G] rs11144898 9 79046297 [T/G] rs11144899 9 79048714 [A/C] rs10869779 9 79055143 [A/G] rs12378119 9 79056003 [A/G] rs11144905 9 79065299 [A/C] NM_001097634 GCNT1 Silent rs10114264 9 79068627 [A/G] NM_001097634 GCNT1 Silent rs10735646 9 79078038 [A/C] NM_001097634,NM_001097633,NM_001490 GCNT1,GCNT1,GCNT1 Silent,Silent,Silent rs1998587 9 79078703 [T/C] NM_001097634,NM_001097633,NM_001490 GCNT1,GCNT1,GCNT1 Silent,Silent,Silent rs7032380 9 79085839 [T/C] NM_001097634,NM_001097633,NM_001490 GCNT1,GCNT1,GCNT1 Silent,Silent,Silent rs785936 9 79093664 [A/G] NM_001097634,NM_001097633,NM_001490,NM_001097635 GCNT1,GCNT1,GCNT1,GCNT1 Silent,Silent,Silent,Silent rs4745552 9 79097144 [T/C] NM_001097634,NM_001097633,NM_001490,NM_001097635 GCNT1,GCNT1,GCNT1,GCNT1 Silent,Silent,Silent,Silent rs785915 9 79100981 [A/G] NM_001097634,NM_001097633,NM_001490,NM_001097635 GCNT1,GCNT1,GCNT1,GCNT1 Silent,Silent,Silent,Silent rs684271 9 79102496 [T/C] NM_001097634,NM_001097633,NM_001490,NM_001097635 GCNT1,GCNT1,GCNT1,GCNT1 Silent,Silent,Silent,Silent rs619429 9 79111675 [A/C] NM_001097634,NM_001097633,NM_001490,NM_001097635 GCNT1,GCNT1,GCNT1,GCNT1 Silent,Silent,Silent,Silent rs4532668 9 79115844 [A/C] NM_001097634,NM_001097633,NM_001490,NM_001097635,NM_001097636 GCNT1,GCNT1,GCNT1,GCNT1,GCNT1 EXON Silent,Silent,Silent,Silent,Silent rs1969980 9 79116108 [A/C] NM_001097634,NM_001097633,NM_001490,NM_001097635,NM_001097636 GCNT1,GCNT1,GCNT1,GCNT1,GCNT1 Silent,Silent,Silent,Silent,Silent rs2282683 9 79117751 [A/G] NM_001097634,NM_001097633,NM_001490,NM_001097635,NM_001097636 GCNT1,GCNT1,GCNT1,GCNT1,GCNT1 EXON Missense_I152V,Missense_I152V,Missense_I152V,Missense_I152V,Missense_I152V rs1057406 9 79118329 [A/G] NM_001097634,NM_001097633,NM_001490,NM_001097635,NM_001097636 GCNT1,GCNT1,GCNT1,GCNT1,GCNT1 EXON Synonymous_L344L,Synonymous_L344L,Synonymous_L344L,Synonymous_L344L,Synonymous_L344L rs707739 9 79118903 [A/C] NM_001097634,NM_001097633,NM_001490,NM_001097635,NM_001097636 GCNT1,GCNT1,GCNT1,GCNT1,GCNT1 EXON Silent,Silent,Silent,Silent,Silent rs683969 9 79119752 [T/C] NM_001097634,NM_001097633,NM_001490,NM_001097635,NM_001097636 GCNT1,GCNT1,GCNT1,GCNT1,GCNT1 EXON Silent,Silent,Silent,Silent,Silent rs785907 9 79121085 [T/G] NM_001097634,NM_001097633,NM_001490,NM_001097635,NM_001097636 GCNT1,GCNT1,GCNT1,GCNT1,GCNT1 EXON Silent,Silent,Silent,Silent,Silent rs1547140 9 79123201 [A/G] rs11144933 9 79123715 [A/G] rs7026142 9 79125260 [A/C] rs17180166 9 79126033 [T/G] rs680448 9 79126953 [A/G] rs543677 9 79134925 [A/G] rs540427 9 79146227 [T/G] rs621293 9 79148376 [T/C] rs652061 9 79150662 [A/G] rs1886268 9 79156769 [T/C] rs673624 9 79159083 [A/G] rs927632 9 79159993 [T/G] rs2771026 9 79160759 [T/C] rs13290974 9 79164646 [A/G] rs13298775 9 79174014 [T/C] rs785896 9 79179861 [A/G] rs7857967 9 79186052 [T/G] rs7042923 9 79188714 [T/G] rs7043420 9 79189090 [A/G] rs2031908 9 79190847 [A/G] rs4237274 9 79198957 [T/C] rs4504705 9 79199853 [A/G] rs2149589 9 79201074 [A/G] rs13291560 9 79203526 [A/G] rs7873112 9 79207324 [A/C] rs2007778 9 79212638 [T/C] rs12345265 9 79217151 [A/G] rs6420275 9 79219334 [A/G] rs7038278 9 79221312 [A/G] rs11144971 9 79223252 [T/C] rs7027116 9 79224492 [T/C] rs812533 9 79225259 [T/C] rs11144978 9 79225328 [A/C] rs3087612 9 79228352 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3802494 9 79228752 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7865529 9 79230108 [T/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs700800 9 79230242 [A/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7865889 9 79230395 [T/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10512062 9 79230575 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1329020 9 79232203 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs786318 9 79233313 [T/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs786319 9 79233633 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17062775 9 79234071 [T/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs700802 9 79234712 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs890152 9 79234786 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs786320 9 79236165 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1536821 9 79236274 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7867457 9 79237318 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs700809 9 79240050 [T/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs786315 9 79241173 [A/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7035759 9 79243280 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs561450 9 79251229 [T/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3739518 9 79253347 [T/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs605523 9 79254447 [T/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10119882 9 79259447 [T/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs512951 9 79259850 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11144992 9 79263092 [T/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7859873 9 79268693 [T/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7018789 9 79272580 [A/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7862059 9 79282119 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17062868 9 79282170 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs666721 9 79282589 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12004137 9 79292138 [T/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs644893 9 79293847 [T/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs514208 9 79293941 [T/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10119188 9 79298047 [A/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs680949 9 79298133 [T/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10123752 9 79298723 [T/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs570222 9 79302025 [A/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs520365 9 79304043 [T/G] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs678943 9 79305709 [T/C] NM_001308047,NM_001308050,NR_131751,NM_001308051,NM_015225,NM_001308048,NM_001308049,NM_001330680 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1536820 9 79307633 [T/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs700757 9 79310246 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs506965 9 79310655 [A/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10521474 9 79318119 [T/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs4745571 9 79318367 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Missense_N2721S,Silent,Missense_N2721S,Missense_N2721S rs560094 9 79318471 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Synonymous_L2686L,Silent,Synonymous_L2686L,Synonymous_L2686L rs561970 9 79318677 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Missense_S2618G,Silent,Missense_S2618G,Missense_S2618G rs620985 9 79318921 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Synonymous_C2536C,Silent,Synonymous_C2536C,Synonymous_C2536C rs620552 9 79318998 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Missense_S2511P,Silent,Missense_S2511P,Missense_S2511P rs3739524 9 79320095 [T/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Missense_L2365F,Silent,Missense_L2365F,Missense_L2365F rs512110 9 79320640 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Missense_A2184T,Silent,Missense_A2184T,Missense_A2184T rs517634 9 79321276 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Missense_T1972A,Silent,Missense_T1972A,Missense_T1972A rs577993 9 79321871 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Synonymous_T1773T,Silent,Synonymous_T1773T,Synonymous_T1773T rs683866 9 79322068 [T/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Missense_H1708N,Silent,Missense_H1708N,Missense_H1708N rs680775 9 79322674 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Missense_C1506R,Silent,Missense_C1506R,Missense_C1506R rs680729 9 79322720 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Synonymous_D1490D,Silent,Synonymous_D1490D,Synonymous_D1490D rs530978 9 79324179 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Missense_T1004M,Silent,Missense_T1004M,Missense_T1004M rs12238013 9 79324439 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Synonymous_D917D,Silent,Synonymous_D917D,Synonymous_D917D rs611461 9 79325615 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 EXON Synonymous_S525S,Silent,Synonymous_S525S,Synonymous_S525S rs12349122 9 79328397 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs9785303 9 79328461 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs17180962 9 79330077 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs890150 9 79333056 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10869801 9 79335621 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs11145032 9 79348193 [A/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs7040264 9 79349008 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs7856888 9 79351237 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs1078986 9 79353911 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10869812 9 79360937 [T/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs11145038 9 79361021 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs2225245 9 79370447 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs9314856 9 79371206 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs1425284 9 79372502 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs4327916 9 79375225 [A/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10521471 9 79381463 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048,NR_015342,NR_132313,NR_132312 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PCA3,PCA3,PCA3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs566234 9 79384370 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048,NR_015342,NR_132313,NR_132312 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PCA3,PCA3,PCA3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs627587 9 79385980 [A/C] NM_001308047,NR_131751,NM_015225,NM_001308048,NR_015342,NR_132313,NR_132312 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PCA3,PCA3,PCA3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs615037 9 79386445 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048,NR_015342,NR_132313,NR_132312 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PCA3,PCA3,PCA3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1936283 9 79390020 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048,NR_015342,NR_132313,NR_132312 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PCA3,PCA3,PCA3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12379174 9 79392249 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048,NR_015342,NR_132313,NR_132312 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PCA3,PCA3,PCA3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12350478 9 79394369 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048,NR_015342,NR_132313,NR_132312 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PCA3,PCA3,PCA3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7861307 9 79395872 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048,NR_015342,NR_132313,NR_132312 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PCA3,PCA3,PCA3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7864683 9 79396072 [T/G] NM_001308047,NR_131751,NM_015225,NM_001308048,NR_015342,NR_132313,NR_132312 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PCA3,PCA3,PCA3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10121266 9 79397265 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048,NR_015342,NR_132313,NR_132312 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PCA3,PCA3,PCA3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12237165 9 79400055 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048,NR_015342,NR_132313,NR_132312 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PCA3,PCA3,PCA3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs954974 9 79400295 [T/G] NM_001308047,NR_131751,NM_015225,NM_001308048,NR_015342,NR_132313,NR_132312 PRUNE2,PRUNE2,PRUNE2,PRUNE2,PCA3,PCA3,PCA3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3924629 9 79402584 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10869820 9 79404589 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs7854027 9 79404749 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs11145066 9 79405428 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10781380 9 79408144 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10781381 9 79412910 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs11145077 9 79420249 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs1343396 9 79424168 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10521470 9 79425692 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10124357 9 79429800 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs3905245 9 79432780 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs1343394 9 79435440 [T/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs7867090 9 79436617 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10869828 9 79437798 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10869829 9 79438813 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs4744812 9 79442798 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10869830 9 79444014 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10869832 9 79445633 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs2000289 9 79450930 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10869838 9 79451775 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs7853555 9 79453107 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs12003722 9 79454353 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10781386 9 79455225 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs1936285 9 79459024 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs12685440 9 79459478 [T/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs17785193 9 79460804 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs6560554 9 79467016 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs1361856 9 79467204 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs1361857 9 79467459 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs6560555 9 79469334 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs4745588 9 79471562 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs12238848 9 79471995 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10116340 9 79477693 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs1125469 9 79500154 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs11145117 9 79504068 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs944561 9 79505493 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs944559 9 79505647 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs2377811 9 79508251 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs7031918 9 79511499 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs2154044 9 79515295 [T/C] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs7035057 9 79518215 [A/G] NM_001308047,NR_131751,NM_015225,NM_001308048 PRUNE2,PRUNE2,PRUNE2,PRUNE2 Silent,Silent,Silent,Silent rs10869843 9 79521736 [A/G] rs3843581 9 79524756 [T/C] rs17787855 9 79526812 [T/C] rs10869844 9 79528772 [T/C] rs1929533 9 79530722 [A/G] rs10121560 9 79537871 [A/G] rs6560565 9 79546523 [A/G] rs10116164 9 79548154 [A/G] rs1011711 9 79550279 [T/C] rs12003945 9 79554513 [A/G] rs12380765 9 79557185 [T/C] rs10217550 9 79561569 [T/G] rs13285464 9 79566864 [A/G] rs7035636 9 79566889 [A/G] rs7027830 9 79569218 [A/G] rs7857541 9 79571921 [T/C] rs11145148 9 79571944 [A/G] rs2183770 9 79574979 [A/G] rs7852521 9 79576188 [T/C] rs7856464 9 79577007 [T/C] rs1929540 9 79578016 [T/C] rs4745601 9 79581742 [T/C] rs1929539 9 79582862 [A/C] rs7856621 9 79584585 [A/C] rs4744815 9 79589352 [A/C] rs11145168 9 79592158 [A/G] rs11145170 9 79592957 [A/G] rs7033468 9 79594546 [T/C] rs10869856 9 79599678 [T/C] rs11145189 9 79603916 [T/G] rs1929538 9 79604018 [T/G] rs1929536 9 79605912 [A/C] rs7853173 9 79607007 [A/G] rs7048169 9 79608487 [A/C] rs7030774 9 79611749 [T/C] rs7858152 9 79612186 [A/G] rs4745607 9 79615741 [T/C] rs4745608 9 79623442 [T/C] rs7027412 9 79629068 [A/G] rs10869866 9 79629718 [T/G] rs12339279 9 79633464 [T/G] rs7044545 9 79636426 [A/G] rs2860108 9 79637519 [T/G] rs7864598 9 79643960 [T/C] rs1928481 9 79646546 [A/C] rs10118945 9 79653957 [T/C] rs11145226 9 79655428 [A/G] rs4744818 9 79658445 [T/C] rs2183767 9 79661589 [T/G] rs11145236 9 79663576 [T/C] rs11145238 9 79664633 [T/C] rs11145239 9 79664647 [T/C] rs4012486 9 79665627 [T/C] rs11145242 9 79666892 [T/C] rs1556152 9 79667495 [T/C] rs10435941 9 79669104 [A/G] rs11145243 9 79669154 [A/G] rs11145246 9 79671228 [A/G] rs11145251 9 79674044 [A/C] rs12352362 9 79677419 [T/C] rs13302493 9 79687816 [A/G] rs11145266 9 79689203 [A/G] rs11145269 9 79691650 [T/C] rs12345375 9 79691690 [A/G] rs10869887 9 79693492 [T/C] rs7029178 9 79695482 [A/G] rs7870404 9 79699406 [A/G] rs7857478 9 79699486 [A/G] rs10156664 9 79700008 [A/G] rs10781417 9 79702675 [T/C] rs10781419 9 79706374 [T/C] rs4361823 9 79707908 [T/C] rs10869896 9 79714137 [T/C] rs7020571 9 79724774 [T/G] rs4484766 9 79726518 [T/G] rs7036418 9 79733481 [T/C] rs4634718 9 79741569 [T/C] rs1953018 9 79747317 [A/G] rs17063363 9 79757557 [A/G] rs12683654 9 79757559 [A/G] rs12345013 9 79761711 [A/G] rs10118161 9 79763338 [T/C] rs4548251 9 79763758 [T/G] rs17723771 9 79773586 [A/G] rs10512064 9 79776332 [A/G] rs7869194 9 79778247 [T/C] rs12156556 9 79783751 [T/G] rs11790663 9 79786834 [A/G] rs17785751 9 79790425 [T/C] rs1054368 9 79791793 [T/C] NR_026668 VPS13A-AS1 EXON Silent rs12338283 9 79802986 [A/G] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs12684856 9 79818630 [A/G] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs10869910 9 79824002 [T/C] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs3802497 9 79835101 [T/C] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs11145347 9 79846516 [T/C] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs2377903 9 79866051 [T/C] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs17063441 9 79866977 [T/C] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs2150904 9 79873690 [A/G] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs17063468 9 79888146 [A/G] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs10781429 9 79888932 [A/C] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs11145366 9 79897117 [A/G] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A EXON Synonymous_P1015P,Synonymous_P1015P,Synonymous_P1015P,Synonymous_P1015P rs12342114 9 79901703 [T/C] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs7033706 9 79906751 [A/G] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs17063524 9 79919647 [A/G] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs9696759 9 79935018 [A/G] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs17423984 9 79936415 [A/G] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A EXON Synonymous_T1861T,Synonymous_T1822T,Synonymous_T1861T,Synonymous_T1861T rs12001097 9 79941851 [A/G] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs17424026 9 79946961 [T/C] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A EXON Synonymous_Y2009Y,Synonymous_Y1970Y,Synonymous_Y2009Y,Synonymous_Y2009Y rs7025532 9 79954545 [T/C] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A EXON Synonymous_D2164D,Synonymous_D2125D,Synonymous_D2164D,Synonymous_D2164D rs10781433 9 79973725 [T/G] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs7041310 9 79978900 [A/G] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs3737289 9 79986057 [A/G] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A EXON Synonymous_G3023G,Synonymous_G2984G,Synonymous_G3023G,Synonymous_G3023G rs2275548 9 79989953 [A/G] NM_001018038,NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A,VPS13A Silent,Silent,Silent,Silent rs12349390 9 79998341 [T/C] NM_001018037,NM_015186,NM_033305 VPS13A,VPS13A,VPS13A Silent,Silent,Silent rs7034531 9 80002460 [T/G] NM_001018037,NM_033305 VPS13A,VPS13A Silent,Silent rs4012460 9 80004213 [T/C] NM_001018037,NM_033305 VPS13A,VPS13A Silent,Silent rs4744831 9 80010025 [A/G] NM_001018037,NM_033305 VPS13A,VPS13A Silent,Silent rs17063594 9 80014376 [A/G] NM_001018037,NM_033305 VPS13A,VPS13A Silent,Silent rs12347526 9 80017018 [T/C] NM_001018037,NM_033305 VPS13A,VPS13A Silent,Silent rs2274486 9 80030829 [T/G] NM_001018037,NM_033305 VPS13A,VPS13A Silent,Silent rs12343797 9 80031144 [A/G] NM_001018037,NM_033305 VPS13A,VPS13A EXON Silent,Silent rs3177 9 80032108 [A/G] NM_001018037,NM_033305 VPS13A,VPS13A EXON Silent,Silent rs17063627 9 80039658 [A/G] NM_004297 GNA14 Silent rs7860724 9 80041641 [A/C] NM_004297 GNA14 Silent rs10747015 9 80041884 [A/G] NM_004297 GNA14 Silent rs2296781 9 80044056 [A/G] NM_004297 GNA14 Silent rs12348357 9 80044563 [A/G] NM_004297 GNA14 Silent rs28395813 9 80046326 [A/G] NM_004297 GNA14 EXON Synonymous_F168F rs1801258 9 80049298 [T/C] NM_004297 GNA14 EXON Synonymous_S150S rs12683817 9 80050810 [A/C] NM_004297 GNA14 Silent rs1327546 9 80053953 [A/G] NM_004297 GNA14 Silent rs1036955 9 80057559 [T/C] NM_004297 GNA14 Silent rs1034014 9 80057994 [A/G] NM_004297 GNA14 Silent rs10781437 9 80058577 [A/C] NM_004297 GNA14 Silent rs11145426 9 80059966 [A/G] NM_004297 GNA14 Silent rs12553676 9 80060071 [T/C] NM_004297 GNA14 Silent rs7039129 9 80060712 [T/C] NM_004297 GNA14 Silent rs12342328 9 80064749 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs12336835 9 80066047 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs4745639 9 80066070 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs12336869 9 80066118 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs10869926 9 80066813 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs3780289 9 80070911 [T/C] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs12352752 9 80070995 [T/C] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs7032444 9 80071833 [T/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs1547190 9 80075134 [T/C] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs3780293 9 80076247 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs3824405 9 80076442 [T/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs7862678 9 80077675 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs734468 9 80078016 [T/C] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs11145434 9 80080976 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs2165962 9 80081202 [A/C] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs990000 9 80086534 [T/C] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs994362 9 80087031 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs7034010 9 80102376 [T/C] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs7029884 9 80109669 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs10781441 9 80110333 [T/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs2889774 9 80112213 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs7047853 9 80115740 [T/C] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs1888980 9 80122834 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs7039992 9 80123488 [T/C] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs11788546 9 80123765 [T/C] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs6560604 9 80124780 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs7041488 9 80124810 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs7852777 9 80124903 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs10121037 9 80125661 [T/C] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs11145450 9 80125731 [T/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs11145452 9 80126898 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs17195438 9 80130546 [T/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs636562 9 80134405 [A/G] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs3780296 9 80137434 [T/C] NM_004297,NR_121184 GNA14,GNA14-AS1 Silent,Silent rs11145462 9 80143110 [A/G] NM_004297 GNA14 Silent rs12346870 9 80144099 [A/G] NM_004297 GNA14 EXON Synonymous_D65D rs4745641 9 80145512 [A/C] NM_004297 GNA14 Silent rs10781444 9 80149172 [T/C] NM_004297 GNA14 Silent rs10869935 9 80149187 [T/C] NM_004297 GNA14 Silent rs1443864 9 80159865 [A/G] NM_004297 GNA14 Silent rs1373254 9 80160010 [T/C] NM_004297 GNA14 Silent rs7046214 9 80162570 [A/C] NM_004297 GNA14 Silent rs11145473 9 80162994 [A/C] NM_004297 GNA14 Silent rs6560606 9 80163049 [A/C] NM_004297 GNA14 Silent rs10869944 9 80164601 [T/C] NM_004297 GNA14 Silent rs7040864 9 80165255 [A/G] NM_004297 GNA14 Silent rs10869945 9 80168128 [T/C] NM_004297 GNA14 Silent rs7035476 9 80169316 [A/G] NM_004297 GNA14 Silent rs10781447 9 80177345 [A/G] NM_004297 GNA14 Silent rs10781448 9 80177554 [T/C] NM_004297 GNA14 Silent rs7860549 9 80180741 [A/G] NM_004297 GNA14 Silent rs10781449 9 80181725 [A/C] NM_004297 GNA14 Silent rs7849646 9 80181751 [T/C] NM_004297 GNA14 Silent rs961572 9 80185929 [T/G] NM_004297 GNA14 Silent rs2440229 9 80186307 [T/G] NM_004297 GNA14 Silent rs1443868 9 80191419 [A/G] NM_004297 GNA14 Silent rs1626834 9 80194682 [T/C] NM_004297 GNA14 Silent rs716080 9 80196611 [T/G] NM_004297 GNA14 Silent rs1772921 9 80196839 [T/G] NM_004297 GNA14 Silent rs755486 9 80198591 [A/G] NM_004297 GNA14 Silent rs1162211 9 80201301 [T/C] NM_004297 GNA14 Silent rs1144434 9 80205948 [T/C] NM_004297 GNA14 Silent rs1144430 9 80209125 [A/G] NM_004297 GNA14 Silent rs1147182 9 80209604 [T/C] NM_004297 GNA14 Silent rs10120776 9 80210750 [T/C] NM_004297 GNA14 Silent rs17788791 9 80213743 [A/G] NM_004297 GNA14 Silent rs1932074 9 80217685 [A/G] NM_004297 GNA14 Silent rs2184481 9 80219681 [T/C] NM_004297 GNA14 Silent rs1953330 9 80221466 [T/G] NM_004297 GNA14 Silent rs2225741 9 80223608 [T/C] NM_004297 GNA14 Silent rs2210755 9 80223823 [T/C] NM_004297 GNA14 Silent rs3905108 9 80226683 [T/C] NM_004297 GNA14 Silent rs12339543 9 80230606 [T/G] NM_004297 GNA14 Silent rs13288161 9 80236438 [T/C] NM_004297 GNA14 Silent rs12344547 9 80244830 [T/G] NM_004297 GNA14 Silent rs7864216 9 80248577 [A/G] NM_004297 GNA14 Silent rs7851160 9 80248797 [A/G] NM_004297 GNA14 Silent rs13289616 9 80248895 [A/G] NM_004297 GNA14 Silent rs11145503 9 80259039 [A/G] NM_004297 GNA14 Silent rs11145504 9 80260083 [T/C] NM_004297 GNA14 Silent rs1122838 9 80263100 [A/G] NM_004297 GNA14 EXON Silent rs10117101 9 80263790 [A/G] rs2236542 9 80263849 [T/C] rs11145506 9 80264584 [T/C] rs35727218 9 80277522 [A/C] rs7027458 9 80279958 [A/C] rs6560609 9 80286142 [T/C] rs11145517 9 80287843 [A/G] rs10869955 9 80293657 [A/C] rs34782998 9 80294359 [T/C] rs2889830 9 80333685 [A/G] NM_002072 GNAQ EXON Silent rs2026000 9 80334981 [A/G] NM_002072 GNAQ EXON Silent rs3780297 9 80342602 [T/C] NM_002072 GNAQ Silent rs2839899 9 80350999 [A/G] NM_002072 GNAQ Silent rs4744849 9 80355515 [T/C] NM_002072 GNAQ Silent rs10869963 9 80364115 [A/C] NM_002072 GNAQ Silent rs10869964 9 80366259 [T/C] NM_002072 GNAQ Silent rs11145552 9 80369188 [T/C] NM_002072 GNAQ Silent rs10747022 9 80371529 [T/C] NM_002072 GNAQ Silent rs11145558 9 80381887 [T/C] NM_002072 GNAQ Silent rs1328531 9 80389921 [T/C] NM_002072 GNAQ Silent rs2118021 9 80414763 [A/G] NM_002072 GNAQ Silent rs1410551 9 80444279 [T/C] NM_002072 GNAQ Silent rs7040165 9 80450215 [T/C] NM_002072 GNAQ Silent rs10869977 9 80457276 [A/G] NM_002072 GNAQ Silent rs17786782 9 80458763 [T/C] NM_002072 GNAQ Silent rs7048503 9 80469561 [A/G] NM_002072 GNAQ Silent rs7048811 9 80469747 [T/G] NM_002072 GNAQ Silent rs11145589 9 80472931 [T/C] NM_002072 GNAQ Silent rs10735654 9 80480997 [T/G] NM_002072 GNAQ Silent rs12352936 9 80485033 [A/G] NM_002072 GNAQ Silent rs1410556 9 80485795 [A/C] NM_002072 GNAQ Silent rs1410555 9 80485900 [T/G] NM_002072 GNAQ Silent rs2209911 9 80487849 [A/G] NM_002072 GNAQ Silent rs10869981 9 80489603 [T/C] NM_002072 GNAQ Silent rs12555424 9 80491636 [T/C] NM_002072 GNAQ Silent rs11145603 9 80496768 [T/C] NM_002072 GNAQ Silent rs10781468 9 80500405 [T/C] NM_002072 GNAQ Silent rs2296937 9 80506587 [T/C] NM_002072 GNAQ Silent rs10781471 9 80515456 [T/G] NM_002072 GNAQ Silent rs4641131 9 80544252 [A/G] NM_002072 GNAQ Silent rs11145626 9 80561271 [A/C] NM_002072 GNAQ Silent rs7035689 9 80561672 [A/G] NM_002072 GNAQ Silent rs10869995 9 80580046 [T/C] NM_002072 GNAQ Silent rs17064001 9 80584749 [A/C] NM_002072 GNAQ Silent rs17064005 9 80589760 [A/G] NM_002072 GNAQ Silent rs7846810 9 80602561 [T/C] NM_002072 GNAQ Silent rs1075369 9 80613593 [T/C] NM_002072 GNAQ Silent rs10870004 9 80618079 [A/G] NM_002072 GNAQ Silent rs4745686 9 80618374 [A/G] NM_002072 GNAQ Silent rs4745687 9 80619811 [A/G] NM_002072 GNAQ Silent rs11145654 9 80628858 [T/C] NM_002072 GNAQ Silent rs10870007 9 80630123 [T/C] NM_002072 GNAQ Silent rs1041584 9 80638165 [T/C] NM_002072 GNAQ Silent rs10870014 9 80650658 [A/C] rs4745694 9 80665785 [T/C] rs7850444 9 80666802 [T/C] rs12353270 9 80668796 [T/C] rs10870028 9 80687873 [A/G] rs950141 9 80704731 [T/G] rs7037675 9 80712566 [T/G] rs10512069 9 80717576 [T/C] rs10781492 9 80718596 [A/G] rs7039240 9 80722684 [T/C] rs7039739 9 80723135 [T/C] rs9969693 9 80724067 [T/G] rs11145699 9 80727620 [A/G] rs11145712 9 80742806 [T/C] rs10512071 9 80746139 [A/G] rs1999437 9 80746584 [A/C] rs10116595 9 80747853 [T/C] rs7854825 9 80747897 [T/C] rs7869891 9 80747989 [A/G] rs7032687 9 80757982 [A/G] rs12351282 9 80763430 [A/G] rs10870056 9 80767173 [A/C] rs7023397 9 80772413 [A/G] rs357631 9 80782539 [T/C] rs12347357 9 80786799 [A/G] rs357642 9 80793672 [T/C] rs7047353 9 80805624 [A/G] rs11145739 9 80807868 [A/G] rs10747028 9 80813104 [A/C] rs10870064 9 80813860 [A/G] rs12238895 9 80827249 [A/G] rs876400 9 80834899 [T/C] rs876399 9 80835033 [T/C] rs10217530 9 80839235 [T/G] rs1571869 9 80842398 [T/C] rs7861244 9 80845906 [A/G] rs4877498 9 80847924 [A/G] rs1571777 9 80854344 [T/G] NM_001349838,NM_001349840,NM_001330693,NM_001330691,NM_032171,NM_001349839,NM_001098802,NM_001330694 CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11137568 9 80854608 [A/G] NM_001349838,NM_001349840,NM_001330693,NM_001330691,NM_032171,NM_001349839,NM_001098802,NM_001330694 CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1929402 9 80863088 [A/G] NM_001349838,NM_001349840,NM_001330693,NM_001330691,NM_032171,NM_001349839,NM_001098802,NM_001330694 CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10867167 9 80865783 [A/G] NM_001349838,NM_001349840,NM_001330693,NM_001330691,NM_032171,NM_001349839,NM_001098802,NM_001330694 CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9696234 9 80868153 [T/C] NM_001349838,NM_001349840,NM_001330693,NM_001330691,NM_032171,NM_001349839,NM_001098802,NM_001330694 CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78 EXON Missense_F404S,Missense_F405S,Missense_F404S,Missense_F404S,Missense_F405S,Missense_F405S,Missense_F405S,Missense_F404S rs17787781 9 80868859 [A/G] NM_001349838,NM_001349840,NM_001330693,NM_001330691,NM_032171,NM_001349839,NM_001098802,NM_001330694 CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12555718 9 80874338 [T/C] NM_001349838,NM_001349840,NM_001330693,NM_001330691,NM_032171,NM_001349839,NM_001098802,NM_001330694 CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1057650 9 80879149 [T/C] NM_001349838,NM_001349840,NM_001330693,NM_001330691,NM_032171,NM_001349839,NM_001098802,NM_001330694 CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78,CEP78 EXON Synonymous_I514I,Synonymous_I515I,Synonymous_I514I,Synonymous_I514I,Synonymous_I515I,Synonymous_I515I,Synonymous_I515I,Synonymous_I514I rs17064276 9 80895853 [A/G] rs10867169 9 80896890 [T/C] rs11137586 9 80901335 [T/G] rs10429454 9 80906946 [A/G] rs17725890 9 80911234 [A/G] rs3824548 9 80911421 [T/G] rs4877550 9 80916382 [A/G] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs3739472 9 80917070 [T/C] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs3758200 9 80918333 [A/G] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs3758201 9 80918420 [T/C] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs7849813 9 80918995 [T/G] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs944514 9 80920757 [T/C] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs10116267 9 80921732 [T/C] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs3739476 9 80923250 [T/C] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs10867178 9 80924008 [A/C] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs7874921 9 80925219 [T/C] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs7875271 9 80927235 [A/G] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs17064306 9 80927815 [A/G] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs7858423 9 80930439 [T/C] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs3780193 9 80932515 [A/C] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs7043123 9 80932887 [T/C] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs10735532 9 80933020 [T/C] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs11137606 9 80935799 [T/C] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs11137607 9 80938001 [A/G] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs3758203 9 80943271 [A/C] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs10780231 9 80943620 [T/C] NM_058179,NM_021154 PSAT1,PSAT1 Silent,Silent rs17064358 9 80944254 [G/C] NM_058179,NM_021154 PSAT1,PSAT1 EXON Silent,Silent rs2776859 9 80946291 [T/C] rs7468433 9 80958478 [T/G] rs2776861 9 80958634 [T/C] rs2788867 9 80958922 [T/C] rs11137617 9 80961655 [A/G] rs17790192 9 80965822 [T/C] rs10521484 9 80966396 [A/G] rs4069725 9 80968185 [A/G] rs10867186 9 80968877 [T/C] rs11137621 9 80972768 [A/G] rs3010744 9 80981110 [A/G] rs2989577 9 80983748 [T/C] rs11137631 9 80985484 [T/C] rs10123128 9 80985638 [A/G] rs7024405 9 80998764 [A/G] rs7868305 9 81002554 [A/C] rs10867190 9 81004205 [A/G] rs10867191 9 81004253 [A/G] rs7027964 9 81012358 [T/G] rs7849881 9 81016144 [A/G] rs7019259 9 81038220 [A/G] rs11137677 9 81047298 [T/C] rs7848904 9 81054215 [T/C] rs7020236 9 81055568 [A/G] rs4498630 9 81057409 [T/G] rs12376992 9 81059643 [T/C] rs10780236 9 81064328 [T/G] rs17081556 9 81069805 [T/C] rs7863422 9 81071842 [A/G] rs3010671 9 81078138 [A/C] rs10125737 9 81083897 [A/G] rs3010681 9 81089830 [A/G] rs7855727 9 81091143 [T/C] rs3010690 9 81094291 [T/G] rs7872028 9 81096795 [T/C] rs2938889 9 81098829 [A/C] rs1394933 9 81100971 [T/G] rs2938900 9 81101590 [A/C] rs2998680 9 81102028 [A/G] rs2998683 9 81106266 [A/G] rs2135238 9 81106476 [A/G] rs2938923 9 81111931 [A/C] rs3010702 9 81116860 [A/G] rs10867212 9 81119846 [A/G] rs3010713 9 81120990 [T/C] rs11137705 9 81121019 [A/G] rs3849862 9 81121174 [T/C] rs3010716 9 81123772 [A/G] rs10867213 9 81132551 [T/G] rs3913784 9 81135377 [T/C] rs1032889 9 81148338 [A/G] rs3010737 9 81152970 [T/C] rs1472773 9 81154501 [T/C] rs7027911 9 81158113 [A/G] rs3009696 9 81158443 [T/C] rs17726343 9 81159309 [T/C] rs1566977 9 81161599 [T/C] rs1105025 9 81162746 [T/C] rs10867216 9 81164099 [A/G] rs3009698 9 81167717 [A/G] rs1505618 9 81168218 [A/G] rs1394926 9 81169107 [T/G] rs2047995 9 81169950 [T/C] rs1466959 9 81171898 [T/C] rs11792922 9 81174574 [A/G] rs870541 9 81178322 [A/G] rs870542 9 81178478 [T/C] rs870543 9 81178617 [T/C] rs883883 9 81179936 [A/G] rs884585 9 81180304 [A/G] rs11137740 9 81188738 [A/G] rs11790951 9 81189439 [A/G] rs9695134 9 81190597 [T/G] rs12551231 9 81191252 [A/C] rs1505641 9 81194641 [A/G] rs10217196 9 81196523 [T/G] rs1505637 9 81196948 [A/G] rs12339181 9 81213820 [T/C] rs769290 9 81217496 [T/C] rs6559399 9 81217634 [A/C] rs12377760 9 81218981 [A/G] rs234804 9 81219689 [T/C] rs10867222 9 81221330 [T/C] rs11137759 9 81223723 [T/C] rs1859061 9 81225091 [A/G] rs234798 9 81226171 [A/G] rs7856547 9 81226596 [T/C] rs4877771 9 81229089 [T/G] rs234795 9 81231055 [A/G] rs234792 9 81240595 [A/G] rs2188902 9 81250966 [A/G] rs2106804 9 81254538 [T/C] rs10867228 9 81259195 [T/C] rs4637921 9 81261677 [A/G] rs7870042 9 81265380 [T/G] rs3009691 9 81272770 [T/C] rs13297134 9 81275274 [T/G] rs2905478 9 81284527 [T/C] rs3008200 9 81285865 [T/C] rs6559401 9 81289385 [T/G] rs2905481 9 81301082 [T/G] rs1757947 9 81315526 [T/G] rs2521904 9 81328432 [A/G] rs6559402 9 81331339 [T/C] rs1634349 9 81333004 [A/G] rs7868916 9 81337236 [A/G] rs1757945 9 81339569 [A/G] rs1929883 9 81344701 [A/G] rs1619442 9 81348300 [T/C] rs1757950 9 81356557 [T/G] rs17788537 9 81356984 [A/G] rs11137821 9 81359983 [A/G] rs10867255 9 81365721 [A/G] rs10867258 9 81370463 [T/C] rs10512079 9 81372519 [A/G] rs10867263 9 81372838 [A/G] rs6559406 9 81378381 [A/G] rs12554407 9 81381363 [T/C] rs7030787 9 81384173 [A/G] rs1929889 9 81384366 [A/G] rs12347476 9 81385545 [A/G] rs11137830 9 81387331 [T/C] rs12340892 9 81387648 [A/G] rs4529531 9 81391164 [T/C] rs12337210 9 81392372 [T/C] rs7848869 9 81394118 [T/G] rs10867271 9 81394862 [A/G] rs10867272 9 81394990 [A/G] rs13299822 9 81398486 [T/G] rs10117274 9 81399854 [T/C] rs10867274 9 81402187 [A/G] rs12349155 9 81402625 [T/C] rs7022062 9 81403141 [T/C] rs11137843 9 81404818 [A/G] rs1929871 9 81404992 [A/G] rs4300072 9 81407851 [T/C] rs3897787 9 81409486 [T/G] rs1929877 9 81414687 [A/G] rs7851210 9 81420820 [T/C] rs6559412 9 81422195 [A/C] rs880403 9 81426189 [A/G] rs12348374 9 81429025 [A/G] rs10780261 9 81434850 [T/C] rs7045330 9 81435312 [T/C] rs11137859 9 81436632 [T/G] rs7867205 9 81436959 [A/G] rs10116105 9 81438539 [T/C] rs11137862 9 81442685 [T/C] rs6559415 9 81443855 [A/G] rs1958925 9 81447644 [A/G] rs1543690 9 81451697 [T/G] rs11137867 9 81455618 [T/C] rs10867289 9 81460812 [A/G] rs12378461 9 81474084 [A/C] rs11137879 9 81476382 [A/G] rs7046415 9 81480696 [A/G] rs11137922 9 81493973 [T/C] rs11137930 9 81497316 [T/C] rs7028992 9 81497488 [T/C] rs10283740 9 81500880 [T/C] rs7028820 9 81506587 [A/G] rs4877311 9 81508579 [A/G] rs10867297 9 81509121 [T/C] rs7867093 9 81518152 [T/G] rs10125496 9 81535490 [A/C] rs10125637 9 81535908 [A/G] rs10780277 9 81552231 [A/G] rs11137960 9 81553066 [A/G] rs1438806 9 81553828 [A/G] rs10512076 9 81554948 [A/C] rs1438805 9 81555504 [T/G] rs1999497 9 81560828 [A/G] rs1930385 9 81566582 [T/C] rs11137969 9 81568457 [T/C] rs7860309 9 81569012 [T/C] rs2218075 9 81569998 [A/C] rs10512074 9 81572766 [A/G] rs10867313 9 81572966 [A/G] rs10867315 9 81574729 [A/G] rs7852123 9 81576070 [A/G] rs10118058 9 81589458 [A/G] rs10867325 9 81591540 [A/G] rs2033817 9 81594461 [A/C] rs4637922 9 81596162 [T/C] rs7852195 9 81606411 [T/C] rs10120084 9 81609142 [A/G] rs10512072 9 81620737 [A/G] rs11137990 9 81622277 [T/C] rs11788493 9 81623111 [A/G] rs11137996 9 81626352 [T/C] rs1341082 9 81627699 [T/C] rs8181181 9 81628077 [A/C] rs1036598 9 81628944 [T/C] rs12376398 9 81629264 [T/C] rs10867328 9 81632946 [T/G] rs11137998 9 81633695 [T/C] rs1014331 9 81634304 [A/C] rs7859992 9 81635735 [A/G] rs10867331 9 81642434 [T/G] rs17082060 9 81642927 [T/G] rs6559441 9 81646444 [T/C] rs6559443 9 81647793 [A/C] rs7874846 9 81648357 [T/C] rs10867333 9 81651602 [T/C] rs10122426 9 81651946 [A/G] rs10512080 9 81657195 [A/G] rs1417653 9 81659736 [T/C] rs6559445 9 81669140 [A/G] rs4242641 9 81671791 [T/G] rs1341086 9 81673370 [A/G] rs7038375 9 81675754 [T/C] rs7031319 9 81678250 [A/G] rs17082093 9 81679224 [T/C] rs4877387 9 81679875 [T/C] rs17082096 9 81680447 [A/G] rs7871268 9 81680914 [A/G] rs12004686 9 81682751 [T/C] rs4556164 9 81687620 [T/C] rs1361537 9 81692440 [T/C] rs17082098 9 81692943 [A/G] rs11138049 9 81696557 [T/C] rs2066259 9 81706625 [A/G] rs7866466 9 81709503 [A/G] rs1544315 9 81720891 [A/C] rs10780291 9 81725579 [T/C] rs11138074 9 81729460 [T/C] rs12001272 9 81738012 [T/G] rs2236578 9 81739976 [T/C] rs11138084 9 81743062 [T/C] rs11138085 9 81745376 [T/C] rs12552083 9 81745871 [T/C] rs10780292 9 81747584 [A/G] rs12686333 9 81754788 [A/G] NR_109771 LOC101927450 Silent rs6559456 9 81757988 [A/G] NR_109771 LOC101927450 Silent rs11138089 9 81758498 [T/C] NR_109771 LOC101927450 Silent rs7023500 9 81758706 [T/C] NR_109771 LOC101927450 Silent rs7023856 9 81758804 [A/G] NR_109771 LOC101927450 Silent rs9314676 9 81759693 [T/C] NR_109771 LOC101927450 Silent rs11138092 9 81760880 [A/C] rs10867350 9 81762607 [T/C] rs11790699 9 81765660 [A/C] rs10732690 9 81766500 [T/C] rs12378835 9 81768535 [A/G] rs4294266 9 81771012 [T/C] rs1032404 9 81771711 [T/C] rs12682880 9 81775281 [A/G] rs10512082 9 81775361 [A/G] rs1341090 9 81775520 [A/G] rs1027263 9 81776086 [T/C] rs1873738 9 81777861 [T/C] rs12554475 9 81778487 [T/C] rs732027 9 81781384 [T/C] rs1361536 9 81782185 [A/G] rs2378309 9 81784956 [A/G] rs1341088 9 81786242 [A/G] rs7850379 9 81791960 [T/C] rs17791273 9 81800073 [A/G] rs7025892 9 81801506 [A/C] rs10465174 9 81808197 [A/C] rs4877474 9 81810992 [A/G] rs4877475 9 81811031 [T/C] rs10122209 9 81812343 [A/G] rs902908 9 81814421 [A/G] rs7872379 9 81816784 [A/G] rs2493600 9 81821091 [T/C] rs11138128 9 81821747 [T/C] rs7846875 9 81824781 [A/G] rs273464 9 81829336 [T/C] rs4877476 9 81830910 [A/C] rs17791387 9 81834426 [A/G] rs273465 9 81835737 [A/C] rs273466 9 81836415 [A/G] rs273469 9 81837195 [T/C] rs17791393 9 81837587 [A/G] rs2769957 9 81839609 [A/G] rs273453 9 81843768 [T/C] rs190640 9 81847769 [T/C] rs273432 9 81866882 [T/G] rs1887719 9 81869419 [A/G] rs11792810 9 81870379 [T/C] rs1753061 9 81870811 [A/G] rs113123 9 81871500 [A/G] rs10746589 9 81872880 [A/G] rs12351466 9 81873321 [A/G] rs273471 9 81874005 [T/C] rs273472 9 81876910 [A/G] rs273473 9 81877286 [A/G] rs4877480 9 81881142 [T/C] rs4486277 9 81882407 [A/G] rs1492611 9 81890076 [T/C] rs10780298 9 81894224 [A/C] rs273449 9 81896716 [A/C] rs273450 9 81897650 [T/C] rs17791483 9 81898980 [A/G] rs17789673 9 81904763 [A/G] rs17791513 9 81905590 [A/G] rs7027362 9 81908179 [A/C] rs1688964 9 81911067 [A/G] rs11138141 9 81916079 [T/C] rs273438 9 81918369 [A/G] rs10512085 9 81924713 [A/G] rs166648 9 81926600 [T/G] rs7026633 9 81928572 [T/C] rs12380408 9 81929517 [T/C] rs10867361 9 81932554 [A/G] rs4877483 9 81936632 [T/G] rs12006184 9 81946034 [T/C] rs4143031 9 81946719 [A/C] rs12683085 9 81951578 [A/G] rs12683067 9 81951599 [T/C] rs7020903 9 81953539 [A/G] rs7021045 9 81953661 [A/G] rs7849719 9 81953998 [A/G] rs4877490 9 81963332 [T/C] rs7043897 9 81966076 [T/C] rs12551528 9 81969812 [A/G] rs7026908 9 81972841 [A/C] rs7859622 9 81974200 [A/G] rs12344408 9 81975178 [A/G] rs10780304 9 81975570 [T/C] rs10780305 9 81978708 [A/G] rs4877493 9 81979548 [T/G] rs10867369 9 81980758 [T/C] rs11138168 9 81983320 [T/C] rs12338373 9 81988322 [T/C] rs12341040 9 81990313 [A/G] rs11138176 9 81994252 [T/C] rs12345803 9 81999215 [A/G] rs2378367 9 82001689 [T/C] rs10867378 9 82004814 [A/G] rs2378373 9 82010265 [A/G] rs10867379 9 82012607 [T/C] rs17800992 9 82015733 [A/G] rs17082349 9 82015765 [T/C] rs10119759 9 82018583 [T/G] rs9314677 9 82018917 [T/C] rs2378377 9 82019860 [A/G] rs1987186 9 82027171 [A/G] rs4556160 9 82032352 [T/C] rs2378380 9 82032456 [T/C] rs9410806 9 82032914 [T/C] rs12554999 9 82042491 [A/C] rs16857 9 82048009 [T/C] rs1578263 9 82051231 [A/C] rs11138220 9 82060528 [T/G] rs11138231 9 82066164 [A/G] rs10491790 9 82080249 [A/G] rs10867389 9 82083763 [T/C] rs10117770 9 82086682 [T/C] rs10117809 9 82086816 [T/C] rs11138252 9 82087111 [T/G] rs7030540 9 82088036 [T/C] rs10491791 9 82096194 [A/G] rs13286432 9 82098952 [A/G] rs12336218 9 82099407 [A/G] rs7867387 9 82116941 [A/G] rs10867395 9 82118185 [T/C] rs1890836 9 82119180 [A/C] rs7870740 9 82121219 [T/G] rs11138270 9 82121684 [T/C] rs7859384 9 82122285 [A/G] rs10867396 9 82122617 [A/G] rs12347524 9 82127183 [T/C] rs10867398 9 82130427 [T/C] rs1417080 9 82130861 [T/C] rs11138277 9 82132941 [T/C] rs12002743 9 82138503 [A/G] rs12351223 9 82140447 [T/C] rs1572803 9 82144364 [A/G] rs7870915 9 82148988 [T/C] rs1538752 9 82152549 [T/C] rs6559483 9 82157404 [T/C] rs7048062 9 82159036 [T/C] rs13291796 9 82165005 [A/G] rs12348335 9 82167845 [T/C] rs10491794 9 82168805 [A/C] rs7037685 9 82169035 [A/C] rs7855614 9 82179241 [T/C] rs7031185 9 82179623 [A/G] rs2807304 9 82185354 [A/G] rs2807302 9 82197735 [A/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11138303 9 82215659 [T/C] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11999556 9 82217647 [T/C] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2807310 9 82225053 [A/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11138311 9 82229981 [T/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7044519 9 82233842 [T/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7029276 9 82234395 [T/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4242612 9 82237934 [T/C] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12337384 9 82243701 [T/C] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9886703 9 82246351 [T/A] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13440432 9 82246520 [T/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11138314 9 82251896 [A/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12553469 9 82263667 [T/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2027006 9 82268575 [A/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7022420 9 82272674 [A/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2027005 9 82275591 [T/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4877146 9 82280362 [T/C] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12342140 9 82282697 [T/C] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7859802 9 82298288 [A/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11138329 9 82298324 [A/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12349682 9 82302985 [A/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7025437 9 82308670 [A/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4242613 9 82311832 [A/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7039267 9 82312046 [A/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11138337 9 82316246 [T/C] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11138340 9 82329295 [T/C] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12345782 9 82330095 [A/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7022923 9 82333000 [A/G] NM_001351552,NM_001282748,NM_001282749,NM_001282753,NM_001351558,NM_001351541,NM_007005,NM_001351542,NR_104239,NM_001351564,NM_001282760,NM_001351562,NM_001351550,NM_001351560,NM_001351547,NM_001351543,NM_001351556,NM_001351563,NM_001351546 TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4,TLE4 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4355856 9 82342503 [T/C] rs2027007 9 82345399 [A/G] rs7023371 9 82352046 [T/C] rs6559497 9 82352255 [T/C] rs10867418 9 82354524 [T/C] rs2149882 9 82354924 [A/G] rs11138350 9 82359588 [T/C] rs4144534 9 82361923 [A/C] rs10867419 9 82362167 [T/C] rs1329743 9 82364676 [T/C] rs10746599 9 82374355 [A/G] rs12003302 9 82375469 [A/G] rs1329742 9 82376584 [T/C] rs1411160 9 82377154 [A/G] rs1888073 9 82377443 [T/G] rs1475673 9 82379253 [A/G] rs10867421 9 82383308 [A/G] rs6559502 9 82392719 [A/G] rs4475583 9 82395528 [T/C] rs977219 9 82399186 [A/G] rs12344214 9 82429313 [A/G] rs12345318 9 82429923 [A/G] rs7039148 9 82430122 [A/G] rs11138361 9 82432302 [A/G] rs12349080 9 82432747 [T/G] rs7037957 9 82433182 [T/C] rs11138362 9 82437835 [T/C] rs4877152 9 82438585 [T/G] rs4273932 9 82439058 [T/C] rs11138364 9 82443844 [T/G] NR_121213 LINC01507 Silent rs11138368 9 82449195 [T/C] NR_121213 LINC01507 Silent rs7873885 9 82455838 [T/C] NR_121213 LINC01507 Silent rs4877517 9 82456587 [T/C] NR_121213 LINC01507 Silent rs7035737 9 82457398 [A/G] NR_121213 LINC01507 Silent rs11138373 9 82457493 [A/G] NR_121213 LINC01507 Silent rs12342683 9 82462882 [A/C] NR_121213 LINC01507 Silent rs7858020 9 82462958 [A/G] NR_121213 LINC01507 Silent rs10512094 9 82465583 [T/C] NR_121213 LINC01507 Silent rs6559507 9 82472582 [T/C] NR_121213 LINC01507 Silent rs11138385 9 82473507 [T/C] NR_121213 LINC01507 Silent rs4877153 9 82474979 [T/G] NR_121213 LINC01507 Silent rs7039360 9 82478788 [T/C] NR_121213 LINC01507 Silent rs10118001 9 82483396 [T/C] NR_121213 LINC01507 Silent rs3894377 9 82485633 [T/C] NR_121213 LINC01507 Silent rs12345503 9 82488433 [A/C] NR_121213 LINC01507 Silent rs12337277 9 82488497 [T/C] NR_121213 LINC01507 Silent rs2274733 9 82489613 [T/G] NR_121213 LINC01507 Silent rs4877518 9 82489957 [T/C] NR_121213 LINC01507 Silent rs17728874 9 82494427 [A/G] NR_121213 LINC01507 Silent rs6559511 9 82495376 [T/C] NR_121213 LINC01507 Silent rs1483023 9 82495768 [A/G] NR_121213 LINC01507 Silent rs267583 9 82503489 [A/G] NR_121213 LINC01507 Silent rs4877521 9 82510157 [A/C] NR_121213 LINC01507 Silent rs7021014 9 82517423 [T/G] NR_121213 LINC01507 Silent rs12553223 9 82523992 [T/C] NR_121213 LINC01507 Silent rs267571 9 82533026 [T/C] NR_121213 LINC01507 Silent rs267574 9 82535883 [A/G] NR_121213 LINC01507 Silent rs11138411 9 82536522 [A/C] NR_121213 LINC01507 Silent rs10746608 9 82536663 [A/C] NR_121213 LINC01507 Silent rs12238216 9 82541282 [T/C] NR_121213 LINC01507 Silent rs388621 9 82542041 [T/G] NR_121213 LINC01507 Silent rs267587 9 82547473 [T/G] NR_121213 LINC01507 Silent rs10867442 9 82551242 [A/C] NR_121213 LINC01507 Silent rs10867444 9 82555561 [A/G] NR_121213 LINC01507 Silent rs7469786 9 82558699 [T/C] NR_121213 LINC01507 Silent rs1329579 9 82559959 [T/G] NR_121213 LINC01507 Silent rs17729039 9 82562184 [T/G] NR_121213 LINC01507 Silent rs7865149 9 82565120 [A/G] NR_121213 LINC01507 Silent rs962883 9 82572208 [A/G] NR_121213 LINC01507 Silent rs11138425 9 82572623 [A/G] NR_121213 LINC01507 Silent rs7853567 9 82579569 [A/G] NR_121213 LINC01507 Silent rs17801845 9 82579689 [A/G] NR_121213 LINC01507 Silent rs12686796 9 82582453 [A/G] NR_121213 LINC01507 Silent rs4877524 9 82582993 [A/G] NR_121213 LINC01507 Silent rs4877525 9 82583014 [T/C] NR_121213 LINC01507 Silent rs1329580 9 82586369 [A/C] NR_121213 LINC01507 Silent rs913757 9 82588226 [A/C] NR_121213 LINC01507 Silent rs11138436 9 82592333 [T/C] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs877950 9 82593704 [A/G] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs7851008 9 82596501 [A/G] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs7024109 9 82597404 [A/G] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs13297228 9 82598756 [A/G] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs7859610 9 82598985 [A/G] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs10780347 9 82602724 [T/C] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs10867451 9 82603623 [A/G] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs7048183 9 82607865 [A/G] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs11138445 9 82609762 [A/G] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs1329576 9 82609825 [T/C] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs6559520 9 82612334 [A/G] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs10780348 9 82613329 [A/G] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs12336334 9 82613387 [A/G] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs11138447 9 82613770 [T/G] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs10746614 9 82616777 [A/G] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs11138454 9 82623065 [A/G] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs1410499 9 82636239 [T/C] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs1328430 9 82646539 [T/C] NR_121213,NR_121212 LINC01507,LINC01507 Silent,Silent rs1410502 9 82654332 [A/G] rs11138465 9 82662587 [T/C] rs10867455 9 82663163 [A/G] rs1074662 9 82664645 [T/C] rs12347897 9 82672704 [A/G] rs7026368 9 82675016 [A/G] rs10283736 9 82676470 [T/C] rs13299280 9 82690543 [A/G] rs12004243 9 82691005 [A/C] rs10746617 9 82695996 [A/G] rs1887722 9 82699351 [A/G] rs7035691 9 82700374 [T/C] rs11138484 9 82703907 [A/G] rs12005290 9 82705241 [T/C] rs4877158 9 82706489 [A/C] rs7865549 9 82713213 [A/G] rs12686238 9 82716095 [A/G] rs10867459 9 82721529 [A/G] rs11138492 9 82726068 [A/C] rs7850306 9 82727367 [A/G] rs7867554 9 82750377 [T/C] rs10114675 9 82759463 [A/G] rs7044051 9 82759818 [A/G] rs4607700 9 82762576 [A/C] rs11138518 9 82768721 [A/G] rs1034053 9 82770941 [T/C] rs11138521 9 82772034 [T/C] rs11138522 9 82772815 [T/C] rs11138527 9 82776693 [T/C] rs17176689 9 82780965 [T/C] rs11788986 9 82781519 [T/C] rs7863707 9 82782923 [A/G] rs11787922 9 82788836 [T/G] rs11787929 9 82789034 [T/C] rs4877161 9 82794251 [T/G] rs10156438 9 82796396 [A/G] rs11138539 9 82796707 [A/G] rs10867476 9 82805488 [A/G] rs1329559 9 82811242 [T/G] rs13294474 9 82815148 [T/C] rs1329555 9 82819611 [T/C] rs1329554 9 82820878 [T/C] rs659968 9 82829118 [A/G] rs17082967 9 82850749 [T/G] rs17082971 9 82851561 [T/C] rs552594 9 82853486 [A/G] rs12553692 9 82855536 [T/G] rs7033100 9 82857894 [A/G] rs10123588 9 82862960 [T/G] rs517274 9 82864918 [A/G] rs17082992 9 82867847 [A/G] rs589737 9 82873587 [T/C] rs587379 9 82874140 [A/G] rs10867485 9 82875336 [A/G] rs604948 9 82879127 [T/C] rs2695 9 82884577 [T/C] rs953506 9 82886345 [A/G] rs602630 9 82889273 [A/G] rs12004190 9 82897180 [T/C] rs1329408 9 82899293 [A/G] rs10780367 9 82900888 [A/G] rs11138590 9 82903566 [T/C] rs7034213 9 82913245 [A/C] rs6559541 9 82916993 [T/C] rs1333937 9 82917653 [T/C] rs11793341 9 82922380 [A/G] rs7044696 9 82926278 [A/G] rs10867496 9 82929577 [A/G] rs1572145 9 82931943 [T/C] rs915004 9 82932712 [A/C] rs1333936 9 82934337 [T/C] rs1333934 9 82935097 [A/C] rs10867499 9 82940654 [A/G] rs17180299 9 82944202 [A/G] rs10119341 9 82944269 [T/C] rs10122600 9 82949474 [A/G] rs1577101 9 82949861 [T/C] rs11138611 9 82950716 [T/G] rs7041680 9 82954954 [A/G] rs10746630 9 82956688 [T/C] rs11787758 9 82962544 [T/C] rs1889283 9 82965051 [T/C] rs7047495 9 82966983 [A/G] rs6559543 9 82968379 [A/G] rs1333940 9 82971893 [A/G] rs17083204 9 82975319 [A/G] rs11138628 9 82976239 [T/C] rs17083209 9 82976555 [T/C] rs10491946 9 82977316 [A/G] rs928537 9 82980785 [T/C] rs7027955 9 82981744 [T/C] rs10746633 9 82985544 [A/C] rs7849222 9 82988782 [T/C] rs4877167 9 82989464 [T/C] rs11138638 9 82990664 [T/G] rs4877557 9 82991662 [T/C] rs10746634 9 82993027 [A/G] rs4278224 9 82993629 [A/G] rs1544230 9 82994364 [A/G] rs2378475 9 82996676 [T/C] rs1541958 9 82999854 [T/C] rs12351772 9 83000227 [T/C] rs7861030 9 83000507 [T/C] rs4877564 9 83001846 [T/C] rs17083249 9 83003091 [A/G] rs17083258 9 83010685 [A/C] rs7864141 9 83013727 [A/G] rs10867523 9 83016971 [A/G] rs10867524 9 83018572 [A/G] rs7044726 9 83021383 [A/C] rs11138651 9 83021572 [T/C] rs991677 9 83024270 [A/G] rs1347374 9 83025449 [T/C] rs7047256 9 83027012 [A/C] rs7029470 9 83029869 [A/G] rs2082710 9 83034282 [A/G] rs4877571 9 83034992 [A/G] rs2378477 9 83035360 [T/C] rs11999186 9 83038535 [T/G] rs11138655 9 83039827 [A/G] rs4877574 9 83040540 [T/G] rs1109201 9 83041867 [A/G] rs1109202 9 83041919 [T/C] rs892686 9 83043376 [A/G] rs11138657 9 83044011 [T/C] rs4144881 9 83044079 [T/C] rs1419273 9 83044102 [A/G] rs1419274 9 83046008 [A/C] rs11138659 9 83048003 [T/C] rs10512102 9 83048441 [A/G] rs10512103 9 83048528 [T/C] rs10867535 9 83055876 [A/G] rs1857469 9 83065765 [T/C] rs7872658 9 83066545 [T/C] rs12238292 9 83069568 [T/C] rs11138672 9 83070204 [A/G] rs11138673 9 83070605 [A/G] rs7860480 9 83070979 [T/C] rs11998832 9 83071931 [A/G] rs4877174 9 83072844 [A/G] rs2378479 9 83073408 [T/G] rs2164186 9 83077768 [A/G] rs2196244 9 83081971 [A/G] rs7862553 9 83083647 [T/C] rs7020677 9 83085633 [A/G] rs17083422 9 83088437 [T/C] rs4612444 9 83089867 [T/C] rs1550051 9 83090265 [A/G] rs11138688 9 83095955 [T/C] rs10867550 9 83096573 [A/G] rs11138689 9 83096816 [T/C] rs10867551 9 83099363 [T/C] rs4877578 9 83099364 [T/G] rs17256174 9 83100591 [A/G] rs10119230 9 83101100 [A/G] rs17256298 9 83104358 [A/C] rs978282 9 83105091 [A/G] rs10867555 9 83107844 [T/C] rs2378481 9 83109040 [T/G] rs10780407 9 83110616 [T/C] rs10780408 9 83111427 [A/G] rs17341528 9 83111466 [A/G] rs11138696 9 83113022 [A/G] rs7034862 9 83113481 [A/G] rs10465167 9 83115815 [A/G] rs1972804 9 83118945 [A/G] rs11138702 9 83120662 [T/C] rs17341942 9 83121611 [T/C] rs2164183 9 83127968 [T/G] rs7019895 9 83128214 [T/C] rs10735546 9 83137302 [A/G] rs7851229 9 83139208 [T/C] rs4877582 9 83141248 [A/G] rs2149342 9 83156867 [T/G] rs4394477 9 83162551 [T/G] rs4590514 9 83162993 [T/G] rs12554921 9 83163922 [A/G] rs7022798 9 83169108 [A/G] rs2209907 9 83169355 [A/G] rs10780428 9 83169672 [T/G] rs10867574 9 83169994 [A/G] rs2296935 9 83171575 [A/G] rs1328500 9 83172180 [T/G] rs10114594 9 83172912 [T/C] rs11791976 9 83173323 [A/G] rs10867575 9 83174096 [T/C] rs928012 9 83174331 [T/C] rs12002329 9 83174758 [T/C] rs11138731 9 83175451 [T/C] rs2225205 9 83187487 [A/C] rs10780435 9 83197939 [T/C] rs6559559 9 83198003 [T/C] rs1328521 9 83199814 [T/G] rs7849462 9 83202032 [T/G] rs17258867 9 83205767 [A/G] rs12551055 9 83207932 [A/G] rs1410550 9 83210614 [A/C] rs1410542 9 83217377 [A/G] rs11138755 9 83221548 [A/G] rs7031624 9 83222111 [T/C] rs12004417 9 83223431 [A/C] rs10867594 9 83232362 [T/C] rs13299090 9 83235117 [T/C] rs10123659 9 83235735 [T/G] rs724372 9 83238535 [T/C] rs10117818 9 83240134 [A/G] rs1328515 9 83241416 [T/C] rs11138767 9 83246133 [T/G] rs4877600 9 83246314 [T/C] rs7019006 9 83247124 [T/G] rs13284117 9 83247711 [T/C] rs10453249 9 83249863 [T/G] rs7040874 9 83252173 [T/C] rs10867599 9 83252509 [T/C] rs11793167 9 83254196 [T/C] rs10867602 9 83259922 [A/C] rs12347101 9 83262428 [T/C] rs12336241 9 83264458 [T/C] rs10867605 9 83279833 [A/G] rs4877611 9 83284684 [A/G] rs4877612 9 83284737 [A/G] rs11138807 9 83290499 [A/C] rs10123247 9 83293714 [T/C] rs12351852 9 83301132 [A/G] rs9695862 9 83306095 [A/C] rs4287017 9 83309521 [A/G] rs7036247 9 83311139 [T/C] rs7022280 9 83316482 [T/G] rs10746668 9 83316951 [T/G] rs17231264 9 83318011 [A/C] rs4142488 9 83320009 [A/G] rs17083946 9 83328730 [T/C] rs10491932 9 83333000 [A/G] rs7855923 9 83333731 [T/C] rs10115500 9 83340723 [T/C] rs1412288 9 83367434 [A/C] rs17083997 9 83367779 [A/G] rs7865140 9 83373425 [A/G] rs12002026 9 83383795 [T/G] rs10867619 9 83387588 [T/C] rs7866547 9 83391430 [A/G] rs4268198 9 83397162 [A/C] rs6559588 9 83397674 [A/G] rs7019400 9 83398603 [T/C] rs1576757 9 83399798 [A/C] rs12346044 9 83404085 [A/G] rs17299918 9 83404401 [T/C] rs10491936 9 83408197 [T/C] rs1359249 9 83412886 [T/C] rs11138854 9 83415561 [T/C] rs12552397 9 83424663 [A/G] rs10735555 9 83429265 [A/G] rs4284104 9 83429615 [A/G] rs4877622 9 83439786 [A/C] rs12000148 9 83441767 [T/C] rs11794073 9 83445616 [A/G] rs728242 9 83447633 [A/G] rs12002342 9 83454689 [T/C] rs7035022 9 83455332 [A/G] rs10435943 9 83457320 [A/G] rs1041039 9 83462500 [T/C] rs17084245 9 83463277 [A/G] rs10746670 9 83465888 [A/G] rs10491940 9 83485092 [A/G] rs11138885 9 83488864 [T/C] rs17242765 9 83490167 [T/C] rs11138887 9 83490812 [T/C] rs11138889 9 83491705 [A/G] rs7863013 9 83493622 [T/C] rs12379326 9 83499061 [T/C] rs10491942 9 83501237 [A/G] rs6559594 9 83501287 [T/C] rs11138895 9 83503203 [A/C] rs10780467 9 83503893 [T/C] rs7025679 9 83513137 [A/C] rs9314695 9 83514230 [T/C] rs10122814 9 83524227 [T/C] rs2209263 9 83526643 [T/C] rs12552136 9 83539913 [A/G] rs1853607 9 83540744 [T/G] rs11138911 9 83541272 [T/C] rs10491943 9 83543246 [A/G] rs716421 9 83547790 [T/C] rs10780472 9 83549419 [T/C] rs715976 9 83549681 [A/G] rs10867651 9 83550453 [T/C] rs10491944 9 83553517 [A/G] rs7859443 9 83559923 [T/C] rs11138936 9 83561050 [T/C] rs10867654 9 83562465 [A/G] rs11138939 9 83567044 [T/C] rs727433 9 83579776 [A/C] rs9314697 9 83583372 [A/G] rs17245550 9 83587426 [A/G] rs10512111 9 83591485 [A/G] rs17084435 9 83592401 [T/C] rs12000341 9 83594111 [A/G] rs10123083 9 83599708 [A/G] rs12344028 9 83603221 [A/G] rs1984064 9 83603802 [T/C] rs11138958 9 83604324 [T/C] rs2378554 9 83615318 [T/C] rs884065 9 83615409 [A/G] rs2378556 9 83620771 [T/C] rs7038882 9 83637462 [A/G] rs1332854 9 83637927 [A/G] rs12347424 9 83638764 [A/C] rs10867678 9 83643130 [A/G] rs1556447 9 83643410 [A/C] rs1572003 9 83643525 [T/G] rs4877200 9 83651543 [T/C] rs12004880 9 83653077 [A/G] rs1332865 9 83655465 [A/C] rs2151225 9 83661308 [A/G] rs7863653 9 83669782 [T/C] rs1186145 9 83670423 [A/G] rs7022470 9 83675496 [A/G] rs1186462 9 83686226 [T/C] rs4527956 9 83690939 [T/C] rs1537342 9 83691262 [A/C] rs1332879 9 83691628 [T/C] rs2779622 9 83693384 [T/G] rs7047671 9 83693947 [A/C] rs2225495 9 83695176 [T/C] rs2779625 9 83695647 [A/G] rs2779627 9 83699819 [T/C] rs10867692 9 83701040 [A/C] rs7856684 9 83701931 [A/G] rs11139023 9 83705606 [T/C] rs11139027 9 83710943 [T/C] rs12237634 9 83712029 [A/G] rs4390020 9 83714890 [T/C] rs4877203 9 83719971 [T/G] rs1929715 9 83720918 [T/C] rs7862233 9 83721188 [A/G] rs10867699 9 83721515 [T/C] rs3927559 9 83726045 [T/C] rs3927561 9 83726176 [T/C] rs11139034 9 83727201 [T/C] rs957692 9 83733322 [A/C] rs7026961 9 83738285 [T/C] rs7860605 9 83751479 [T/C] rs17084584 9 83751955 [T/C] rs7470833 9 83752021 [A/G] rs11790515 9 83759957 [A/G] rs1999415 9 83763114 [A/G] rs2809849 9 83763800 [T/C] rs2777673 9 83774420 [A/G] rs2777674 9 83774885 [A/G] rs2809845 9 83776258 [T/G] rs2777678 9 83790397 [T/C] rs10780493 9 83796167 [A/G] rs10115607 9 83799212 [A/G] rs4378037 9 83808939 [T/C] rs11139068 9 83811684 [T/C] rs10114161 9 83822268 [A/G] rs7869606 9 83838856 [A/G] rs4258072 9 83839273 [A/G] rs4614076 9 83848710 [T/G] rs7867933 9 83850716 [A/G] rs17084654 9 83856150 [T/C] rs10125589 9 83857814 [T/C] rs4484778 9 83858558 [A/G] rs4526433 9 83861324 [A/G] rs12000290 9 83865218 [A/G] rs10125662 9 83867125 [A/G] rs4517197 9 83868297 [T/G] rs9987634 9 83872854 [A/G] rs12377896 9 83873695 [A/G] rs10867720 9 83874230 [A/G] rs7037283 9 83880284 [T/C] rs11139105 9 83882277 [A/C] rs17271965 9 83887652 [A/C] rs7033981 9 83887790 [T/C] rs6559617 9 83890416 [T/C] rs10114445 9 83892569 [A/G] rs10780502 9 83893170 [T/C] rs4428744 9 83898946 [A/C] rs7042916 9 83898995 [A/G] rs13298109 9 83909232 [A/C] rs11139132 9 83915924 [A/G] rs11139145 9 83923806 [T/C] rs4639587 9 83928428 [A/G] rs7869128 9 83928740 [A/C] rs10867734 9 83933198 [A/G] rs10119867 9 83941281 [T/G] rs1888172 9 83950452 [A/G] rs1330210 9 83950550 [A/G] rs10780510 9 83959411 [T/C] rs10867740 9 83963524 [A/C] rs4452888 9 83974745 [T/C] rs10867741 9 83975947 [T/C] rs11139170 9 83977478 [T/C] rs11792869 9 83978906 [T/C] rs2183369 9 83984974 [T/C] rs7043176 9 83985310 [T/C] rs11139174 9 83985424 [A/G] rs11139175 9 83986104 [T/C] rs12115572 9 83987167 [T/C] rs7874548 9 83988392 [A/G] rs10867745 9 83989882 [A/G] rs11139182 9 83993434 [A/C] rs1329387 9 83998047 [T/C] rs12376965 9 83998114 [T/C] rs3906153 9 84006993 [A/G] rs3860892 9 84007124 [T/C] rs3860894 9 84007235 [A/G] rs7869726 9 84007864 [T/C] rs10780512 9 84008633 [A/G] rs3908631 9 84009625 [T/C] rs7866986 9 84011111 [T/C] rs10780513 9 84012054 [T/G] rs10122399 9 84013017 [T/G] rs10867751 9 84013508 [T/C] rs11139214 9 84020189 [T/C] rs11139218 9 84023250 [T/C] rs11139219 9 84023759 [T/C] rs9918949 9 84026512 [T/C] rs12345913 9 84029173 [A/C] rs10118881 9 84029999 [T/C] rs12339226 9 84030732 [T/C] rs7028565 9 84033464 [A/G] rs7036348 9 84034924 [A/C] rs11794168 9 84035574 [A/C] rs6559627 9 84053760 [T/C] rs12344650 9 84055480 [A/G] rs12348817 9 84059393 [A/G] rs11139263 9 84070398 [A/G] rs1329383 9 84070426 [T/C] rs11139265 9 84073624 [T/C] rs7862405 9 84074754 [T/C] rs10217345 9 84077767 [A/G] rs663838 9 84088631 [T/C] rs7871047 9 84090670 [T/G] rs10123329 9 84102451 [A/G] rs12377364 9 84103358 [T/G] rs10512118 9 84105189 [T/C] rs584846 9 84113944 [A/C] rs602405 9 84115380 [A/G] rs495519 9 84116843 [A/G] rs524783 9 84117747 [T/G] rs594548 9 84124991 [T/G] rs12336229 9 84139376 [A/G] rs10115264 9 84140380 [T/C] rs1576733 9 84141525 [A/C] rs11139298 9 84144714 [A/C] rs12376717 9 84146693 [A/G] rs11139301 9 84148456 [T/C] rs7045463 9 84152604 [T/G] rs4877214 9 84160842 [A/C] rs7043518 9 84164493 [A/G] rs815863 9 84165251 [A/G] rs815866 9 84170326 [A/C] rs815867 9 84170701 [A/G] rs7029222 9 84173486 [A/G] rs11139315 9 84181238 [T/G] rs944591 9 84182228 [A/G] rs7045345 9 84182613 [A/G] rs10867775 9 84183227 [A/C] rs10780519 9 84183462 [T/C] rs12377054 9 84185097 [A/G] rs10780521 9 84185365 [T/C] rs11139321 9 84187401 [A/C] rs10780522 9 84191049 [A/G] rs7027019 9 84191267 [T/C] rs11139324 9 84191525 [A/G] rs1412224 9 84192036 [T/C] rs17084936 9 84193897 [A/G] rs4877217 9 84195189 [A/G] rs10481754 9 84196490 [T/C] rs11139328 9 84197169 [A/G] rs2796460 9 84201594 [A/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs2796462 9 84202226 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs2777772 9 84204332 [T/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs911639 9 84204374 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs2796466 9 84204779 [T/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs6559629 9 84207360 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs2796471 9 84207857 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs2777774 9 84208347 [A/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs7860224 9 84210148 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs7860431 9 84210209 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs7036755 9 84210838 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs864179 9 84211820 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs1573078 9 84212536 [A/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs7018978 9 84213955 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs7039820 9 84214974 [T/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs3897745 9 84215944 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs815845 9 84216090 [A/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs10867778 9 84222230 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs815847 9 84222618 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs870713 9 84227158 [A/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs7028704 9 84230322 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs7029058 9 84233764 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs7045319 9 84233782 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs10867781 9 84233892 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs1888812 9 84236729 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs7856380 9 84236942 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs10867783 9 84238812 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs11139346 9 84241442 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs11139349 9 84244131 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs7856583 9 84244444 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs12379295 9 84245004 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs1342478 9 84247426 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs10780524 9 84247453 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs10867784 9 84249963 [A/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs11139351 9 84252359 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs10867787 9 84254819 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs12551040 9 84256984 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs11999426 9 84261124 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs4877669 9 84262485 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs10867791 9 84262687 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs2796449 9 84270400 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs2627002 9 84275014 [A/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs10119841 9 84281312 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs12003063 9 84281816 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs2591 9 84288353 [T/C] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs3739581 9 84289295 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs10867795 9 84297696 [A/G] NM_005077,NM_001303103,NM_001303104 TLE1,TLE1,TLE1 Silent,Silent,Silent rs3814535 9 84304985 [A/G] NR_109772 LOC101927502 Silent rs1484113 9 84305732 [T/G] NR_109772 LOC101927502 Silent rs2796441 9 84308948 [A/G] NR_109772 LOC101927502 Silent rs7018614 9 84314437 [T/G] NR_109772 LOC101927502 Silent rs7020734 9 84319890 [T/C] NR_109772 LOC101927502 Silent rs11787711 9 84323545 [A/G] NR_109772 LOC101927502 Silent rs4877223 9 84323900 [A/G] NR_109772 LOC101927502 Silent rs2627013 9 84327210 [A/G] NR_109772 LOC101927502 Silent rs7023749 9 84333124 [T/C] NR_109772 LOC101927502 Silent rs3860897 9 84344542 [T/G] NR_109772 LOC101927502 Silent rs4434691 9 84348762 [A/C] NR_109772 LOC101927502 Silent rs10512121 9 84352443 [T/G] NR_109772 LOC101927502 Silent rs11139391 9 84353330 [A/G] NR_109772 LOC101927502 Silent rs7041897 9 84358072 [A/G] NR_109772 LOC101927502 Silent rs12683003 9 84365210 [T/C] NR_109772 LOC101927502 Silent rs7864030 9 84369450 [A/G] NR_109772 LOC101927502 Silent rs13287994 9 84370124 [A/C] NR_109772 LOC101927502 Silent rs1007995 9 84371927 [A/G] NR_109772 LOC101927502 Silent rs12377016 9 84373428 [T/G] NR_109772 LOC101927502 Silent rs1010745 9 84386712 [A/G] NR_109772 LOC101927502 Silent rs11139407 9 84386769 [A/G] NR_109772 LOC101927502 Silent rs17085042 9 84389168 [A/C] NR_109772 LOC101927502 Silent rs7847362 9 84389731 [A/C] NR_109772 LOC101927502 Silent rs10867812 9 84389914 [T/C] NR_109772 LOC101927502 Silent rs10081631 9 84391174 [T/C] NR_109772 LOC101927502 EXON Silent rs637736 9 84392044 [A/G] rs676113 9 84399614 [T/C] rs564171 9 84402241 [A/G] rs609658 9 84408808 [T/C] rs7030006 9 84410212 [A/G] rs630561 9 84414429 [T/G] rs669223 9 84419758 [T/G] rs7048179 9 84431758 [A/G] rs2281936 9 84437960 [T/C] rs10121323 9 84441027 [A/G] rs10441783 9 84444308 [A/G] rs12351774 9 84445182 [A/G] rs11139438 9 84445414 [T/C] rs2031757 9 84451844 [T/C] rs10867818 9 84454027 [T/C] rs7874530 9 84455672 [T/C] rs10780536 9 84456361 [A/G] rs478787 9 84457989 [A/G] rs7867888 9 84458091 [A/G] rs11139442 9 84458774 [T/G] rs478381 9 84459072 [T/C] rs1854158 9 84460636 [T/C] rs10867821 9 84460855 [T/C] rs17370182 9 84461318 [A/C] rs4999155 9 84462943 [T/C] rs7024973 9 84473474 [A/G] rs7037280 9 84481989 [T/C] rs2378592 9 84495227 [A/G] rs7847877 9 84498795 [T/G] rs2184427 9 84510772 [T/C] rs12351812 9 84519154 [T/C] rs10217389 9 84528161 [A/G] rs11795190 9 84564258 [T/C] NM_207416 SPATA31D3 EXON Silent rs6559647 9 84565837 [T/C] rs7866133 9 84573066 [A/C] rs12236406 9 84580411 [T/C] rs11139464 9 84589488 [A/G] rs11139465 9 84589869 [A/C] rs4877228 9 84600972 [A/G] rs12376340 9 84602453 [T/C] rs1999661 9 84603019 [T/C] rs11789866 9 84604024 [T/G] NM_001001670 SPATA31D1 Silent rs10118455 9 84605293 [A/G] NM_001001670 SPATA31D1 Silent rs10867827 9 84618966 [A/G] rs12344007 9 84642933 [T/C] rs12342760 9 84672279 [T/C] rs7867431 9 84686091 [A/T] rs7034868 9 84697395 [A/G] rs1319017 9 84736303 [A/G] rs12338960 9 84743408 [A/G] rs11139500 9 84763025 [T/C] rs4877686 9 84765612 [A/G] rs2767719 9 84789243 [A/G] rs11139516 9 84812176 [T/C] rs12345577 9 84818814 [T/C] rs2209725 9 84828677 [T/C] rs2788099 9 84843011 [T/C] rs12000571 9 84891965 [A/C] rs1933577 9 84894926 [A/G] rs11139535 9 84919492 [T/C] rs11794308 9 84929102 [A/G] rs7859493 9 84935895 [T/C] rs10512124 9 84950712 [A/G] rs1933580 9 84951226 [T/C] rs10119281 9 84982726 [A/G] rs6559659 9 84982792 [T/C] rs12352042 9 85000366 [A/G] rs10123160 9 85027979 [A/C] rs12551702 9 85036598 [A/G] rs7049209 9 85036817 [T/C] rs6559663 9 85039435 [T/G] rs11999685 9 85060949 [T/C] rs7031935 9 85067584 [A/G] rs12684844 9 85072253 [A/G] rs12685656 9 85080395 [A/G] rs7046558 9 85088990 [A/C] rs1411661 9 85097651 [T/G] rs11139579 9 85101768 [T/G] rs1411664 9 85106906 [A/G] rs7875416 9 85107147 [A/G] rs955975 9 85117420 [A/G] rs928223 9 85128341 [A/C] rs1330828 9 85134671 [A/G] rs7043482 9 85135915 [A/C] rs10780547 9 85139211 [A/G] rs6559670 9 85147648 [A/G] rs11139601 9 85147773 [T/C] rs2378640 9 85150039 [T/G] rs7019706 9 85153087 [T/G] rs11139606 9 85161570 [A/G] rs10867852 9 85163682 [T/C] rs11139607 9 85166081 [T/C] rs10780548 9 85167648 [A/G] rs1009037 9 85168377 [T/C] rs7035264 9 85168848 [A/G] rs17085582 9 85171613 [A/C] rs1933015 9 85175417 [A/G] rs7030914 9 85181786 [T/C] rs1933016 9 85182996 [T/C] rs7036580 9 85186899 [T/C] rs7022118 9 85187051 [T/G] rs7864333 9 85187079 [A/G] rs7019337 9 85190433 [A/G] rs11139631 9 85197241 [T/G] rs11139635 9 85200045 [A/G] rs10118901 9 85206133 [T/C] rs7028728 9 85209810 [A/G] rs17085618 9 85210881 [A/G] rs11139649 9 85216270 [T/C] rs11139654 9 85220698 [T/C] rs10512130 9 85227767 [T/C] rs17085644 9 85228687 [A/G] rs7873931 9 85237252 [T/C] rs10441790 9 85246766 [T/G] rs7031058 9 85256142 [A/G] rs11139665 9 85261201 [T/G] rs1537302 9 85267179 [A/G] rs12057032 9 85272505 [T/C] rs17085684 9 85282258 [T/C] rs10867868 9 85288781 [T/C] rs7875440 9 85290284 [A/G] rs1571905 9 85296585 [A/G] rs7025180 9 85297244 [T/C] rs11139689 9 85303653 [A/G] rs668853 9 85311147 [T/C] rs10119442 9 85314307 [A/G] rs493701 9 85321895 [A/G] rs509091 9 85326428 [T/C] rs12236312 9 85329887 [T/C] rs581729 9 85332687 [T/C] rs11139709 9 85338256 [T/G] rs11139710 9 85339429 [T/C] rs609444 9 85347613 [T/G] rs11139720 9 85353762 [A/G] rs7043569 9 85359511 [A/G] rs11791304 9 85359985 [A/C] rs11139727 9 85362958 [A/G] rs11139732 9 85365505 [A/G] rs11139754 9 85374993 [T/G] rs11139766 9 85390604 [T/C] rs932638 9 85391686 [A/C] rs7859706 9 85391724 [A/G] rs7875501 9 85391790 [T/C] rs1570228 9 85394979 [A/G] rs11139775 9 85395554 [A/G] rs11788842 9 85397699 [T/C] rs4877709 9 85400266 [A/G] rs963727 9 85406002 [A/G] rs1998304 9 85409526 [T/C] rs10867884 9 85410090 [T/C] rs35433085 9 85412760 [T/C] rs1040870 9 85415537 [T/C] rs1005796 9 85417267 [T/C] rs12342232 9 85421474 [T/C] rs11139797 9 85425162 [T/G] rs1885348 9 85428983 [A/C] rs10491544 9 85430415 [A/G] rs2378645 9 85430642 [A/G] rs987371 9 85432032 [A/C] rs11792316 9 85434314 [A/G] rs6559685 9 85436498 [A/G] rs7874804 9 85437593 [A/G] rs4877240 9 85440941 [T/C] rs10867893 9 85443579 [A/G] rs2208619 9 85444907 [A/G] rs11139822 9 85451313 [A/G] rs10867903 9 85451416 [T/G] rs12349496 9 85452097 [T/C] rs13440407 9 85453867 [T/C] rs10514829 9 85454114 [T/C] rs2224524 9 85458060 [A/G] rs2208622 9 85459107 [T/C] rs10867906 9 85460807 [A/G] rs12335900 9 85460852 [T/C] rs10491542 9 85467302 [A/G] rs12002556 9 85478265 [T/C] rs12684912 9 85478756 [T/C] rs12683498 9 85481263 [A/G] rs9987635 9 85489244 [A/C] rs10867909 9 85490188 [A/G] rs11139849 9 85490520 [T/C] rs12235637 9 85492701 [T/C] rs10867910 9 85493025 [T/G] rs4357374 9 85495552 [A/G] rs7875448 9 85495968 [A/C] rs7038698 9 85506296 [A/C] rs10867914 9 85509355 [A/C] rs10746692 9 85511305 [A/C] rs11139863 9 85511504 [A/G] rs7026976 9 85521271 [A/G] rs4554557 9 85524530 [T/G] rs4604527 9 85524569 [T/C] rs11139868 9 85527035 [T/C] rs3897456 9 85527950 [A/G] rs12340476 9 85540229 [A/C] rs7860062 9 85547017 [A/G] rs17745151 9 85552173 [A/G] rs7032152 9 85557505 [A/G] rs7029717 9 85559944 [T/C] rs17085888 9 85564404 [A/G] rs11139881 9 85570577 [A/G] rs10867918 9 85574053 [T/C] rs10780559 9 85577007 [A/G] rs4620356 9 85579528 [A/C] rs2999948 9 85590972 [T/C] rs10735559 9 85596321 [T/C] NM_152573 RASEF EXON Silent rs4385545 9 85601796 [A/C] NM_152573 RASEF Silent rs4355855 9 85601818 [A/G] NM_152573 RASEF Silent rs2279814 9 85608152 [A/G] NM_152573 RASEF Silent rs10867921 9 85609781 [A/G] NM_152573 RASEF Silent rs6559694 9 85613043 [A/G] NM_152573 RASEF Silent rs4348583 9 85623560 [T/C] NM_152573 RASEF Silent rs4146960 9 85627408 [A/G] NM_152573 RASEF EXON Missense_R262C rs7019227 9 85639259 [A/G] NM_152573 RASEF Silent rs10867929 9 85643603 [T/C] NM_152573 RASEF Silent rs1125915 9 85650916 [T/C] NM_152573 RASEF Silent rs1948797 9 85657836 [T/C] NM_152573 RASEF Silent rs17085989 9 85661953 [A/G] NM_152573 RASEF Silent rs10116216 9 85663674 [A/G] NM_152573 RASEF Silent rs1995423 9 85680418 [A/G] rs7024275 9 85698493 [A/C] rs1502687 9 85702264 [A/G] rs7855133 9 85704334 [A/C] rs11536913 9 85704575 [T/C] rs7020876 9 85715039 [T/C] rs6559697 9 85715943 [T/C] rs1995424 9 85719699 [A/G] rs4311721 9 85721071 [A/G] rs2378646 9 85721119 [T/C] rs11795101 9 85725775 [A/C] rs17307723 9 85735656 [T/C] rs7862814 9 85736106 [A/G] rs11139921 9 85748119 [A/G] rs6559700 9 85751913 [A/G] rs1502680 9 85756459 [T/C] rs1502681 9 85756528 [T/C] rs10780572 9 85760746 [A/G] rs17308295 9 85764146 [T/C] rs11139927 9 85764196 [A/G] rs7040878 9 85765521 [T/C] rs952744 9 85766721 [T/C] rs7043147 9 85778241 [A/G] rs7860585 9 85781109 [A/G] rs11139935 9 85781504 [A/C] rs11139936 9 85781709 [T/G] rs4322086 9 85787718 [A/G] rs1575506 9 85788822 [A/G] rs12555032 9 85788944 [A/G] rs17308435 9 85793511 [T/C] rs17080551 9 85794098 [A/G] rs11139942 9 85797104 [T/C] rs13290606 9 85797799 [T/C] rs12336763 9 85797854 [T/C] rs11139944 9 85798722 [A/G] rs11139945 9 85798771 [A/G] rs7869902 9 85798903 [T/C] rs1323763 9 85799271 [T/C] rs10867947 9 85806577 [T/C] rs17400083 9 85808051 [T/C] rs4282648 9 85808708 [T/G] rs10780576 9 85808730 [T/C] rs7046769 9 85808790 [A/G] rs10115371 9 85810910 [A/G] rs11139953 9 85811540 [T/C] rs1323766 9 85811825 [A/G] rs7864580 9 85812142 [A/C] rs17400257 9 85812953 [A/C] rs11139955 9 85813385 [T/C] rs8181176 9 85813465 [A/G] rs6559711 9 85813844 [A/G] rs12682758 9 85821621 [T/C] rs12335503 9 85826840 [T/C] rs1323771 9 85833127 [A/G] rs11139974 9 85833585 [T/C] rs1408101 9 85834349 [T/G] rs10114830 9 85835108 [A/C] rs11139976 9 85835157 [A/G] rs10867954 9 85845746 [T/C] rs10867956 9 85847317 [A/G] rs11139984 9 85849031 [A/C] rs10780579 9 85849458 [T/C] rs4877740 9 85851830 [T/G] rs10117817 9 85855600 [T/C] rs1048228 9 85859648 [T/G] NM_001244961,NM_001244959,NM_001244962,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3,FRMD3 EXON Silent,Silent,Silent,Silent,Silent rs10867964 9 85861561 [T/C] NM_001244961,NM_001244959,NM_001244962,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3,FRMD3 EXON Silent,Silent,Silent,Silent,Silent rs10114696 9 85863091 [A/G] NM_001244961,NM_001244959,NM_001244962,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3,FRMD3 EXON Synonymous_Y318Y,Synonymous_Y512Y,Synonymous_Y169Y,Synonymous_Y468Y,Synonymous_Y512Y rs4877747 9 85863174 [A/C] NM_001244961,NM_001244959,NM_001244962,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3,FRMD3 EXON Missense_D291Y,Missense_D485Y,Missense_D142Y,Missense_D441Y,Missense_D485Y rs4877748 9 85865631 [T/C] NM_001244961,NM_001244959,NM_001244962,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent,Silent rs4877750 9 85872664 [T/C] NM_001244961,NM_001244959,NM_001244962,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent,Silent rs13294854 9 85872940 [T/C] NM_001244961,NM_001244959,NM_001244962,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent,Silent rs2889953 9 85874113 [A/G] NM_001244961,NM_001244959,NM_001244962,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent,Silent rs12339855 9 85876399 [A/G] NM_001244961,NM_001244959,NM_001244962,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent,Silent rs10867967 9 85876633 [A/G] NM_001244961,NM_001244959,NM_001244962,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent,Silent rs12336597 9 85876870 [T/C] NM_001244961,NM_001244959,NM_001244962,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent,Silent rs1323781 9 85879636 [T/C] NM_001244961,NM_001244959,NM_001244962,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent,Silent rs9695210 9 85881204 [A/G] NM_001244961,NM_001244959,NM_001244962,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent,Silent rs13296597 9 85882323 [T/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs10512138 9 85883879 [T/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs4877751 9 85885299 [A/G] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs13298532 9 85891266 [T/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs10867970 9 85895419 [A/G] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs2209186 9 85904384 [A/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs2378658 9 85904778 [A/G] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs1535753 9 85905060 [A/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs10117251 9 85909882 [T/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs1570582 9 85910512 [A/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs11140009 9 85910642 [T/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs1535750 9 85910950 [A/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs11140010 9 85912228 [T/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs1359168 9 85914243 [A/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs11140018 9 85925309 [T/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs2031261 9 85927157 [A/G] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs10867985 9 85927600 [T/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs1408106 9 85929821 [T/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs10123088 9 85930972 [T/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs17086147 9 85932455 [T/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs4361831 9 85937637 [A/G] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs3903842 9 85942341 [A/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs10867988 9 85943575 [A/G] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs10867991 9 85944604 [T/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs10867992 9 85944803 [T/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs17086156 9 85945797 [T/C] NM_001244961,NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3,FRMD3 Silent,Silent,Silent,Silent rs12555197 9 85947759 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs7861973 9 85949206 [A/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs10780595 9 85951471 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs2889243 9 85954902 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs4242620 9 85955438 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs3860902 9 85959871 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs10780596 9 85960840 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs2375885 9 85963579 [T/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs2277176 9 85964563 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs2277175 9 85964735 [A/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs3889596 9 85969893 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs11140046 9 85970165 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs7035160 9 85977276 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs10868000 9 85980087 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs11140056 9 85981967 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs1556149 9 85986905 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs3739657 9 85987935 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs3739656 9 85988205 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs4877757 9 85989187 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs10512140 9 85997312 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs4084066 9 85998802 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs6559721 9 86000430 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs7870557 9 86001996 [A/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs17086209 9 86003591 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs3739655 9 86004436 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs10117284 9 86007105 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs11140065 9 86007259 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs6559722 9 86011428 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs4145729 9 86014433 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs10868004 9 86016834 [T/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs17086223 9 86020127 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs7035287 9 86021132 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs3860916 9 86021400 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs10119608 9 86022007 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs10512141 9 86024195 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs7039438 9 86029329 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs11140072 9 86031577 [A/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs12343136 9 86036512 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs3860918 9 86038298 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs3889637 9 86038847 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs11140081 9 86041189 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs11140082 9 86041302 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs10217669 9 86042009 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs7019130 9 86042288 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs4877761 9 86044173 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs11140087 9 86045746 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs11140088 9 86048288 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs3860922 9 86048883 [T/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs7875766 9 86052275 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs2375919 9 86055337 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs11999447 9 86056670 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs11140090 9 86057113 [T/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs4145727 9 86058964 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs10868009 9 86061834 [A/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs4877767 9 86069237 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs11140102 9 86071342 [A/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs4014024 9 86075411 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs11140109 9 86078128 [T/C] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs7855690 9 86080928 [T/G] NM_001244959,NM_001244960,NM_174938 FRMD3,FRMD3,FRMD3 Silent,Silent,Silent rs7019064 9 86086115 [A/G] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs7850633 9 86086600 [T/C] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs17086298 9 86086887 [T/C] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs12000033 9 86088061 [A/G] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs10746709 9 86088871 [T/C] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs7032223 9 86089295 [A/C] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs12348445 9 86092096 [T/C] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs17086319 9 86093237 [T/C] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs5014093 9 86093654 [A/G] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs10868019 9 86099092 [T/C] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs10746712 9 86100539 [T/G] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs12350888 9 86102626 [A/G] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs7873385 9 86102933 [A/G] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs6559728 9 86103862 [A/G] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs3860935 9 86105137 [T/C] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs3860938 9 86108027 [T/G] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs3860941 9 86108665 [A/G] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs11140123 9 86111068 [A/C] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs12551103 9 86111242 [T/C] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs7863524 9 86112734 [T/G] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs12552693 9 86117401 [T/C] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs7043959 9 86127539 [A/G] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs17086403 9 86135188 [T/G] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs7849075 9 86149610 [T/C] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs7863215 9 86149786 [A/G] NM_001244959,NM_174938 FRMD3,FRMD3 Silent,Silent rs1888746 9 86155392 [T/C] rs2210381 9 86156348 [T/G] rs13289150 9 86164428 [A/G] rs6559732 9 86168692 [T/C] rs3934902 9 86177401 [A/G] rs7025704 9 86178646 [T/C] rs4451390 9 86179563 [T/C] rs11793821 9 86184504 [A/G] rs4877258 9 86185455 [T/C] rs7032583 9 86191111 [T/C] rs12341482 9 86195933 [A/G] rs2780991 9 86199324 [T/G] rs1572134 9 86200547 [T/C] rs12001341 9 86203246 [A/G] rs17086501 9 86203301 [A/G] rs17321848 9 86206343 [T/G] rs10113885 9 86216008 [T/C] rs2811897 9 86216100 [A/G] rs2780984 9 86217059 [T/G] rs2780983 9 86217430 [T/C] rs10868031 9 86220040 [A/G] rs11790364 9 86221436 [A/G] rs7865279 9 86226119 [A/G] rs7848656 9 86229249 [T/G] rs949864 9 86231370 [A/C] rs2780982 9 86232809 [T/C] rs2780980 9 86234596 [A/G] rs2282221 9 86242901 [A/G] NM_001256915,NR_046422,NR_046421,NM_001001551,NM_001351535 IDNK,IDNK,IDNK,IDNK,IDNK Silent,Silent,Silent,Silent,Silent rs2282222 9 86242994 [T/G] NM_001256915,NR_046422,NR_046421,NM_001001551,NM_001351535 IDNK,IDNK,IDNK,IDNK,IDNK EXON Silent,Silent,Silent,Silent,Silent rs2811907 9 86244359 [T/C] NM_001256915,NR_046422,NR_046421,NM_001001551,NM_001351535 IDNK,IDNK,IDNK,IDNK,IDNK Silent,Silent,Silent,Silent,Silent rs2811913 9 86253482 [T/C] NM_001256915,NR_046422,NR_046421,NM_001001551,NM_001351535 IDNK,IDNK,IDNK,IDNK,IDNK Silent,Silent,Silent,Silent,Silent rs1052690 9 86258685 [A/C] NM_001256915,NR_046422,NR_046421,NM_001001551,NM_001351535 IDNK,IDNK,IDNK,IDNK,IDNK EXON Missense_K139T,Silent,Silent,Missense_K185T,Missense_K139T rs9410586 9 86260234 [A/G] rs2811921 9 86265425 [T/C] rs2781006 9 86273487 [T/C] rs7866234 9 86278817 [A/C] NM_013438,NM_053067 UBQLN1,UBQLN1 EXON Synonymous_L530L,Synonymous_L502L rs12344615 9 86281195 [A/G] NM_013438,NM_053067 UBQLN1,UBQLN1 Silent,Silent rs2058912 9 86281995 [A/G] NM_013438,NM_053067 UBQLN1,UBQLN1 Silent,Silent rs2811929 9 86283423 [A/G] NM_013438,NM_053067 UBQLN1,UBQLN1 Silent,Silent rs1044175 9 86284178 [A/C] NM_013438,NM_053067 UBQLN1,UBQLN1 EXON Synonymous_L390L,Synonymous_L390L rs11140212 9 86297669 [T/C] NM_013438,NM_053067 UBQLN1,UBQLN1 Silent,Silent rs4877796 9 86304008 [T/G] NM_013438,NM_053067 UBQLN1,UBQLN1 Silent,Silent rs17086576 9 86305360 [T/C] NM_013438,NM_053067 UBQLN1,UBQLN1 Silent,Silent rs12115755 9 86309269 [T/C] NM_013438,NM_053067 UBQLN1,UBQLN1 Silent,Silent rs3814507 9 86323309 [T/C] NR_135839,NR_135840 LOC105376114,LOC105376114 EXON Silent,Silent rs11793897 9 86332843 [T/C] rs7020313 9 86347254 [T/C] rs7047832 9 86359578 [T/C] NM_025211,NM_001135953 GKAP1,GKAP1 Silent,Silent rs10868053 9 86368105 [A/G] NM_025211,NM_001135953 GKAP1,GKAP1 Silent,Silent rs7047907 9 86368660 [A/G] NM_025211,NM_001135953 GKAP1,GKAP1 Silent,Silent rs10868054 9 86369356 [A/G] NM_025211,NM_001135953 GKAP1,GKAP1 Silent,Silent rs7855177 9 86381582 [A/G] NM_025211,NM_001135953 GKAP1,GKAP1 Silent,Silent rs11140240 9 86381814 [A/G] NM_025211,NM_001135953 GKAP1,GKAP1 Silent,Silent rs11140241 9 86383740 [T/C] NM_025211,NM_001135953 GKAP1,GKAP1 EXON Missense_H244R,Silent rs7021357 9 86399815 [T/C] NM_025211,NM_001135953 GKAP1,GKAP1 Silent,Silent rs4297107 9 86404584 [T/C] NM_025211,NM_001135953 GKAP1,GKAP1 Silent,Silent rs9314723 9 86426620 [T/C] NM_025211,NM_001135953 GKAP1,GKAP1 Silent,Silent rs7021609 9 86443840 [T/G] rs7027121 9 86448944 [A/G] rs7853625 9 86488586 [T/C] NM_001354071,NM_001354070,NM_017576,NM_001271927,NM_001271928,NM_001354069 KIF27,KIF27,KIF27,KIF27,KIF27,KIF27 Silent,Silent,Silent,Silent,Silent,Silent rs13290882 9 86497334 [A/G] NM_001354071,NM_001354070,NM_017576,NM_001271927,NM_001271928,NM_001354069 KIF27,KIF27,KIF27,KIF27,KIF27,KIF27 Silent,Silent,Silent,Silent,Silent,Silent rs1034187 9 86514207 [A/G] NM_001354071,NM_001354070,NM_017576,NM_001271927,NM_001271928,NM_001354069 KIF27,KIF27,KIF27,KIF27,KIF27,KIF27 Silent,Silent,Silent,Silent,Silent,Silent rs12001918 9 86518796 [T/C] NM_001354071,NM_001354070,NM_017576,NM_001271927,NM_001271928,NM_001354069 KIF27,KIF27,KIF27,KIF27,KIF27,KIF27 EXON Silent,Silent,Missense_I213V,Missense_I213V,Missense_I213V,Missense_I213V rs7857619 9 86525399 [T/G] NM_001354071,NM_001354070,NM_017576,NM_001271927,NM_001271928,NM_001354069 KIF27,KIF27,KIF27,KIF27,KIF27,KIF27 Silent,Silent,Silent,Silent,Silent,Silent rs10868072 9 86534480 [T/C] NM_001354071,NM_001354070,NM_017576,NM_001271927,NM_001271928,NM_001354069 KIF27,KIF27,KIF27,KIF27,KIF27,KIF27 Silent,Silent,Silent,Silent,Silent,Silent rs11140294 9 86534759 [T/C] NM_001354071,NM_001354070,NM_017576,NM_001271927,NM_001271928,NM_001354069 KIF27,KIF27,KIF27,KIF27,KIF27,KIF27 Silent,Silent,Silent,Silent,Silent,Silent rs12552069 9 86535730 [A/G] NM_001354071,NM_001354070,NM_017576,NM_001271927,NM_001271928,NM_001354069 KIF27,KIF27,KIF27,KIF27,KIF27,KIF27 Silent,Silent,Silent,Silent,Silent,Silent rs4298563 9 86539603 [T/C] rs10124390 9 86549939 [A/C] rs3180887 9 86553589 [A/G] NM_032307,NM_001317997 C9orf64,C9orf64 EXON Silent,Silent rs11140304 9 86558270 [A/G] NM_032307,NM_001317997 C9orf64,C9orf64 Silent,Silent rs7025244 9 86559359 [A/G] NM_032307,NM_001317997 C9orf64,C9orf64 Silent,Silent rs36082863 9 86559713 [A/G] NM_032307,NM_001317997 C9orf64,C9orf64 EXON Synonymous_L263L,Synonymous_L122L rs11140305 9 86561633 [T/C] NM_032307,NM_001317997 C9orf64,C9orf64 Silent,Silent rs1572031 9 86571798 [T/G] NM_001317997 C9orf64 Silent rs11140316 9 86593443 [T/C] NM_001318188,NM_031263,NM_001318186,NM_031262,NM_001318187,NM_002140 HNRNPK,HNRNPK,HNRNPK,HNRNPK,HNRNPK,HNRNPK Silent,Silent,Silent,Silent,Silent,Silent rs17086750 9 86593815 [T/G] NM_001318188,NM_031263,NM_001318186,NM_031262,NM_001318187,NM_002140 HNRNPK,HNRNPK,HNRNPK,HNRNPK,HNRNPK,HNRNPK Silent,Silent,Silent,Silent,Silent,Silent rs296887 9 86595070 [T/C] NM_001318188,NM_031263,NM_001318186,NM_031262,NM_001318187,NM_002140 HNRNPK,HNRNPK,HNRNPK,HNRNPK,HNRNPK,HNRNPK EXON Silent,Silent,Silent,Silent,Silent,Silent rs296888 9 86595498 [A/G] NM_031262,NM_002140,NM_001358294 HNRNPK,HNRNPK,RMI1 EXON Silent,Silent,Silent rs1982151 9 86617265 [A/G] NM_001358294,NM_001358292,NM_001358293,NM_024945,NM_001358291 RMI1,RMI1,RMI1,RMI1,RMI1 EXON Missense_N455S,Missense_N455S,Missense_N455S,Missense_N455S,Missense_N455S rs2118168 9 86618233 [A/C] NM_001358294,NM_001358292,NM_001358293,NM_024945,NM_001358291 RMI1,RMI1,RMI1,RMI1,RMI1 EXON Silent,Silent,Silent,Silent,Silent rs4877815 9 86623268 [A/G] rs6559758 9 86625243 [A/G] rs10868083 9 86646572 [T/G] rs11793330 9 86666444 [A/G] rs973460 9 86667098 [A/G] rs11140345 9 86669330 [A/G] rs11140350 9 86676854 [T/G] rs10868091 9 86679251 [T/C] NR_110995 LOC101927575 Silent rs1898321 9 86682315 [T/C] NR_110995 LOC101927575 EXON Silent rs11140355 9 86687791 [A/G] NR_110995 LOC101927575 Silent rs12000600 9 86690657 [A/G] NR_110995 LOC101927575 EXON Silent rs7857500 9 86691975 [T/C] NR_110995 LOC101927575 Silent rs2118166 9 86693470 [T/C] NR_110995 LOC101927575 Silent rs11795036 9 86693912 [A/T] NR_110995 LOC101927575 Silent rs12339554 9 86696287 [T/C] NR_110995 LOC101927575 Silent rs10868094 9 86696749 [A/G] NR_110995 LOC101927575 Silent rs17086797 9 86700593 [A/G] NR_110995 LOC101927575 Silent rs4471123 9 86700737 [A/G] NR_110995 LOC101927575 Silent rs11788077 9 86700760 [A/G] NR_110995 LOC101927575 Silent rs4449867 9 86700822 [A/G] NR_110995 LOC101927575 Silent rs11140361 9 86701021 [A/G] NR_110995 LOC101927575 Silent rs7029403 9 86707888 [A/G] NR_110995 LOC101927575 Silent rs12349329 9 86708868 [T/C] NR_110995 LOC101927575 Silent rs17086818 9 86709041 [T/C] NR_110995 LOC101927575 Silent rs7032296 9 86713990 [A/G] rs7032430 9 86714002 [A/C] rs7853970 9 86715566 [T/C] rs10868097 9 86716873 [A/G] rs893150 9 86718822 [A/G] rs1529952 9 86719547 [T/C] rs10868100 9 86721015 [A/C] rs11789466 9 86721077 [A/G] rs6559768 9 86721929 [T/C] rs11140381 9 86724391 [T/C] rs11140383 9 86725070 [A/G] rs7848501 9 86735718 [A/G] rs11140391 9 86736004 [T/C] rs2889956 9 86736068 [A/G] rs2118169 9 86742278 [A/G] rs7028167 9 86743347 [A/C] rs13284104 9 86743543 [A/G] rs7357702 9 86744106 [A/G] rs11140398 9 86749003 [A/G] rs2799850 9 86750762 [T/C] rs11140400 9 86750781 [A/G] rs10512144 9 86751792 [T/C] rs7029843 9 86757023 [T/C] rs1246267 9 86758069 [A/G] rs1246264 9 86761781 [T/C] rs1273061 9 86763217 [T/C] rs1246274 9 86770003 [A/G] rs7027670 9 86770610 [A/G] rs996503 9 86771168 [T/C] rs963761 9 86772993 [T/C] rs1147187 9 86774339 [A/G] rs1147189 9 86774848 [T/C] rs6559770 9 86776381 [T/C] rs2250159 9 86777046 [T/C] rs2250005 9 86778137 [T/C] rs2249998 9 86778277 [T/C] rs1932652 9 86778415 [A/G] rs2246348 9 86786231 [A/G] rs2246240 9 86787001 [T/C] rs10868107 9 86788022 [A/G] rs2245993 9 86789200 [A/C] rs11140416 9 86789306 [A/G] rs2245980 9 86789462 [A/G] rs7039156 9 86791333 [T/G] rs7042904 9 86792058 [T/C] rs10868111 9 86793008 [A/C] rs2256603 9 86794631 [T/G] rs17425371 9 86795274 [T/C] rs3893387 9 86796094 [T/C] rs2265721 9 86802590 [T/C] rs1272566 9 86806595 [A/G] rs2251760 9 86811147 [T/C] rs2251530 9 86812940 [A/G] rs11140439 9 86818413 [A/G] rs12336636 9 86818665 [A/G] rs2484894 9 86820581 [T/C] rs7466124 9 86824068 [A/G] rs7861108 9 86826872 [A/C] rs7874528 9 86830499 [T/G] rs4877822 9 86831182 [A/G] rs4877271 9 86831936 [A/G] rs7045243 9 86834719 [A/G] rs6559774 9 86836666 [A/G] rs4877823 9 86838505 [T/C] rs10780656 9 86841402 [T/C] rs956727 9 86846933 [A/G] rs7024751 9 86853384 [A/G] rs4877824 9 86855859 [A/G] rs4877826 9 86857433 [T/C] rs4877827 9 86859971 [T/C] rs883431 9 86867036 [T/C] rs1015951 9 86868157 [T/C] rs11140471 9 86868447 [A/G] rs17086979 9 86868638 [A/G] rs10512146 9 86870757 [A/C] rs12683783 9 86870808 [T/C] rs11140476 9 86872684 [A/G] rs4877829 9 86873532 [A/G] rs12684950 9 86876931 [A/G] rs7857113 9 86878682 [A/G] rs12348345 9 86879344 [A/G] rs11140482 9 86880493 [T/C] rs10780659 9 86881490 [A/C] rs2184747 9 86884890 [A/G] rs11790651 9 86886897 [T/G] rs1332538 9 86888818 [T/C] rs12003423 9 86889644 [A/G] rs7851917 9 86890073 [A/C] rs10868132 9 86890592 [T/G] rs17426961 9 86890758 [T/C] rs10868134 9 86892119 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 EXON Silent,Silent,Silent rs17087039 9 86892606 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 EXON Silent,Silent,Silent rs11140490 9 86893313 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4316212 9 86893729 [A/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4436199 9 86893734 [T/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs10121999 9 86896198 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs12686790 9 86896586 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs13286567 9 86897558 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4877833 9 86900016 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs11140494 9 86900332 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 EXON Silent,Synonymous_H525H,Synonymous_H525H rs7853066 9 86900613 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7853758 9 86900926 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 EXON Silent,Synonymous_L461L,Synonymous_L461L rs4585823 9 86904185 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs9695529 9 86904335 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7042987 9 86904754 [T/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs10441793 9 86905035 [T/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7043492 9 86905096 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 EXON Silent,Synonymous_S374S,Synonymous_S374S rs12350045 9 86905439 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4877834 9 86905551 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7047315 9 86906008 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs6559779 9 86906107 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7864584 9 86906932 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs11568418 9 86907624 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 EXON Silent,Missense_I328V,Missense_I328V rs7357642 9 86907673 [A/T] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs9695936 9 86907750 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7042416 9 86908480 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs12343928 9 86908830 [A/T] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs10868137 9 86909082 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7030202 9 86909399 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs885003 9 86909435 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs885004 9 86909550 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs3812512 9 86911824 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs3812511 9 86912628 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs3812510 9 86912815 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs11140500 9 86913781 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs11791990 9 86914268 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs17087049 9 86914372 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs11140503 9 86914503 [T/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 EXON Silent,Missense_P221Q,Missense_P221Q rs11999726 9 86915156 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7861242 9 86915542 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4877835 9 86916851 [T/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs12342617 9 86916910 [T/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4877836 9 86917088 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4877837 9 86917382 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7867504 9 86920236 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 EXON Silent,Synonymous_T89T,Synonymous_T89T rs12337391 9 86920321 [A/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs12685409 9 86920632 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4242626 9 86920711 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs12379208 9 86921361 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs12379481 9 86921564 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs10868142 9 86921615 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs13288052 9 86922777 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs11795099 9 86924704 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs9792674 9 86925655 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs11140507 9 86925748 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs10780660 9 86925846 [T/A] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs9792596 9 86925874 [T/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs10780661 9 86926307 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs11140508 9 86926892 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs11140510 9 86928133 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs10780662 9 86928403 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7863627 9 86928497 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs11140511 9 86928905 [A/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4877842 9 86929380 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7853499 9 86930823 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs12335576 9 86930977 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7853538 9 86931003 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs10780663 9 86931062 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs11140519 9 86932764 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs12347156 9 86932859 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs17336552 9 86933046 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7035188 9 86933405 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs10122651 9 86933884 [A/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs10868145 9 86933934 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs10868146 9 86934074 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs10868147 9 86934277 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs12340619 9 86934696 [G/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs11140521 9 86935306 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs11140522 9 86935429 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs11140525 9 86937315 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4877845 9 86939823 [A/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7033971 9 86940014 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs13283683 9 86941443 [C/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4305983 9 86944451 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4242627 9 86944921 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs13285844 9 86945393 [A/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs17343066 9 86946073 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4877847 9 86946417 [A/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs980292 9 86946607 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4266723 9 86948616 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs13283321 9 86949847 [A/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs10868149 9 86949973 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4877848 9 86950870 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4877850 9 86951615 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs17087134 9 86952770 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4618776 9 86952945 [A/T] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7022853 9 86953046 [A/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs17428030 9 86953621 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7043257 9 86953674 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs4877851 9 86954132 [A/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7027983 9 86954466 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7031197 9 86954717 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs12346493 9 86954799 [A/G] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs3812509 9 86955157 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 Silent,Silent,Silent rs7035753 9 86955682 [T/C] NR_037638,NM_022127,NM_001199633 SLC28A3,SLC28A3,SLC28A3 EXON Silent,Silent,Silent rs17343456 9 86956612 [A/G] NM_022127 SLC28A3 Silent rs7854119 9 86957209 [T/C] NM_022127 SLC28A3 Silent rs12335486 9 86958566 [A/G] NM_022127 SLC28A3 Silent rs12335567 9 86958726 [A/G] NM_022127 SLC28A3 Silent rs10780664 9 86960060 [A/C] NM_022127 SLC28A3 Silent rs12351012 9 86960066 [T/C] NM_022127 SLC28A3 Silent rs12346191 9 86960121 [T/C] NM_022127 SLC28A3 Silent rs7851030 9 86960337 [A/G] NM_022127 SLC28A3 Silent rs12347587 9 86961343 [T/G] NM_022127 SLC28A3 Silent rs12348567 9 86961522 [C/G] NM_022127 SLC28A3 Silent rs12348550 9 86961626 [T/C] NM_022127 SLC28A3 Silent rs17087143 9 86962866 [A/C] NM_022127 SLC28A3 Silent rs11140540 9 86963524 [T/C] NM_022127 SLC28A3 Silent rs7860537 9 86963692 [T/G] NM_022127 SLC28A3 Silent rs13297855 9 86964575 [T/C] NM_022127 SLC28A3 Silent rs13298157 9 86964656 [A/G] NM_022127 SLC28A3 Silent rs11140543 9 86966200 [T/C] NM_022127 SLC28A3 Silent rs11140544 9 86966759 [T/G] NM_022127 SLC28A3 Silent rs17087148 9 86969052 [A/G] NM_022127 SLC28A3 Silent rs10868152 9 86970543 [T/C] NM_022127 SLC28A3 Silent rs7024793 9 86971134 [A/G] NM_022127 SLC28A3 Silent rs4877854 9 86971246 [T/C] NM_022127 SLC28A3 Silent rs12552512 9 86972086 [T/C] NM_022127 SLC28A3 Silent rs10115380 9 86972649 [T/C] NM_022127 SLC28A3 Silent rs7033918 9 86973500 [T/C] NM_022127 SLC28A3 Silent rs6559783 9 86975499 [A/G] NM_022127 SLC28A3 Silent rs12336027 9 86976543 [G/C] NM_022127 SLC28A3 Silent rs17087151 9 86978338 [T/G] NM_022127 SLC28A3 Silent rs17087152 9 86978392 [T/C] NM_022127 SLC28A3 Silent rs10868153 9 86983368 [T/G] NM_022127 SLC28A3 EXON Silent rs12378361 9 86983672 [T/G] rs11140555 9 86991225 [T/C] rs7021071 9 86994670 [A/G] rs11140557 9 86994945 [A/G] rs12555868 9 87000794 [T/C] rs586046 9 87004182 [A/G] rs12004770 9 87004892 [A/G] rs12379161 9 87008860 [A/G] rs10780674 9 87013515 [A/G] rs11140582 9 87015151 [T/C] rs7042275 9 87026298 [T/G] rs12340455 9 87035345 [A/C] rs17087215 9 87036462 [A/G] rs10780677 9 87050410 [T/C] rs7870219 9 87050694 [A/G] rs13286078 9 87056301 [A/C] rs17087228 9 87057020 [T/C] rs7868516 9 87062568 [A/G] rs17087262 9 87075033 [A/G] rs1332535 9 87075137 [T/G] rs7875211 9 87082451 [A/G] rs1326930 9 87085182 [T/C] rs2778944 9 87086912 [T/C] rs4877276 9 87089546 [T/C] rs7034008 9 87091511 [A/C] rs12004826 9 87092975 [A/C] rs13292359 9 87096223 [A/G] rs7872425 9 87097373 [T/G] rs4433222 9 87097512 [A/C] rs11140629 9 87099638 [T/G] rs11140631 9 87106841 [T/C] rs1409706 9 87107049 [A/G] rs13290191 9 87114620 [T/C] rs12004605 9 87118778 [T/C] rs12685148 9 87125877 [T/C] rs10868171 9 87127736 [T/C] rs10868175 9 87130393 [T/C] rs7871278 9 87135644 [A/G] rs1926746 9 87143351 [A/C] rs11507096 9 87154874 [T/C] rs7859601 9 87160854 [A/G] rs11140663 9 87167205 [A/G] rs7849491 9 87168860 [T/C] rs1347857 9 87173097 [T/G] rs1347858 9 87173333 [A/C] rs12115546 9 87177985 [A/G] rs1866439 9 87179264 [A/G] rs11792906 9 87182696 [T/C] rs11140676 9 87190178 [A/G] rs2118819 9 87193728 [T/C] rs2218090 9 87200556 [A/G] rs9886924 9 87201325 [T/C] rs11788721 9 87203787 [T/C] rs7021722 9 87208419 [T/C] rs715243 9 87216845 [A/C] rs4111912 9 87217628 [A/G] rs12001901 9 87218231 [T/C] rs10868213 9 87221357 [A/C] rs1020120 9 87226088 [T/C] rs10122112 9 87227397 [A/G] rs4877869 9 87231641 [A/G] rs10868215 9 87234111 [T/C] rs12005792 9 87236739 [T/C] rs11789677 9 87238610 [A/G] rs11140693 9 87239147 [A/G] rs11140694 9 87240130 [T/C] rs11140695 9 87240403 [A/C] rs17087472 9 87246051 [A/G] rs11140704 9 87248164 [A/G] rs11140705 9 87248623 [A/G] rs11140707 9 87250190 [A/G] rs985543 9 87251183 [A/G] rs10868220 9 87251376 [A/G] rs10124751 9 87252641 [A/G] rs17087514 9 87253419 [A/G] rs1187333 9 87266352 [A/G] rs11140714 9 87266700 [A/G] rs1439054 9 87267699 [A/G] rs11140720 9 87272824 [A/C] rs1147199 9 87275895 [A/G] rs1307279 9 87281307 [T/C] rs1212171 9 87282527 [T/C] rs3758317 9 87282615 [T/C] rs1439050 9 87288193 [T/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1187350 9 87295237 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1619120 9 87302196 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1187343 9 87308783 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1187337 9 87316037 [T/C] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs13290917 9 87321367 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs12683368 9 87340841 [T/C] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs3824518 9 87344369 [T/C] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1419245 9 87346919 [T/C] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs7044057 9 87348718 [A/C] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs3780632 9 87352788 [T/C] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs11140745 9 87355358 [T/C] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1573219 9 87387622 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs10465180 9 87392582 [T/C] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs4877880 9 87392708 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1778970 9 87395810 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1662697 9 87395876 [T/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs17080621 9 87398104 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1662695 9 87405212 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1443440 9 87406168 [T/C] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1899640 9 87409025 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs17087710 9 87409862 [T/C] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1187287 9 87414794 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1187286 9 87415028 [T/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1187280 9 87416825 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs716893 9 87419117 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs3739804 9 87421631 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent,Silent,Silent rs1047896 9 87425973 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 EXON Silent,Silent,Silent,Silent,Silent,Silent rs2013566 9 87426298 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 EXON Silent,Silent,Silent,Silent,Silent,Silent rs1624327 9 87429290 [A/G] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 EXON Silent,Silent,Silent,Silent,Silent,Silent rs3654 9 87430491 [T/C] NM_001291937,NM_006180,NM_001018066,NM_001018065,NM_001007097,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2,NTRK2,NTRK2 EXON Silent,Silent,Silent,Silent,Silent,Silent rs10512154 9 87441475 [A/G] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent rs10780687 9 87442302 [A/G] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent rs2083828 9 87447045 [A/C] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent rs1867283 9 87450766 [A/G] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent rs7855888 9 87452058 [T/C] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent rs11140783 9 87454817 [T/C] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent rs4486281 9 87455347 [A/G] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent rs11791654 9 87465791 [T/G] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent rs1838158 9 87473009 [A/G] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent rs10868231 9 87474397 [A/G] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent rs10116287 9 87477274 [T/G] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent rs7048015 9 87478135 [A/C] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent rs7873546 9 87482723 [T/G] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent rs4877289 9 87484613 [A/G] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 Silent,Silent,Silent,Silent rs3780634 9 87488718 [A/G] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 EXON Silent,Silent,Silent,Silent rs10780691 9 87491253 [T/C] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 EXON Silent,Silent,Silent,Silent rs3739806 9 87491621 [T/C] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 EXON Silent,Silent,Silent,Silent rs1221 9 87492610 [T/C] NM_006180,NM_001018066,NM_001018065,NM_001018064 NTRK2,NTRK2,NTRK2,NTRK2 EXON Silent,Silent,Silent,Silent rs9314736 9 87499252 [T/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs12685376 9 87505172 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs11140799 9 87506932 [T/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs11791891 9 87512412 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs11140803 9 87512669 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs4304401 9 87530511 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs10868238 9 87530935 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs6559836 9 87533389 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs10512157 9 87533427 [A/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs11788989 9 87541540 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs1545285 9 87542369 [T/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs7045900 9 87542728 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs17087884 9 87548647 [A/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs12340212 9 87551964 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs7858142 9 87552575 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs6559838 9 87553563 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs7855989 9 87556420 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs2808707 9 87558294 [T/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs10512158 9 87560184 [T/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs1078947 9 87563252 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs2289658 9 87563370 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs2289656 9 87563562 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs1002261 9 87566307 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs7026337 9 87568014 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs7046974 9 87570862 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs2586566 9 87570912 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs2277192 9 87573977 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs2277193 9 87574009 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs11140810 9 87574808 [T/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs6559840 9 87575500 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs17087959 9 87575920 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs1899637 9 87576008 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs2034107 9 87580367 [T/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs984430 9 87582827 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs3860945 9 87585624 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs7026417 9 87589165 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs4877894 9 87590382 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs10868241 9 87593028 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs4361832 9 87595734 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs4504715 9 87600078 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs10512159 9 87608999 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs4419891 9 87609384 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs17088001 9 87610439 [T/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs12341232 9 87612473 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs1948308 9 87616257 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs923559 9 87616532 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs7036165 9 87618012 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs4394478 9 87618385 [A/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs13440094 9 87619071 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs17418241 9 87625848 [T/C] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs1387924 9 87632993 [T/G] NM_006180,NM_001018064 NTRK2,NTRK2 Silent,Silent rs1073049 9 87647100 [T/C] rs11140831 9 87647454 [A/G] rs10435949 9 87651621 [T/G] rs10780697 9 87654393 [T/C] rs681329 9 87659399 [A/G] rs474899 9 87660797 [A/C] rs475335 9 87676586 [T/G] rs7042038 9 87694716 [T/C] rs17348377 9 87696145 [T/C] rs615189 9 87697154 [T/C] rs544862 9 87699138 [A/G] rs2780936 9 87699646 [A/G] rs11999991 9 87701841 [T/G] rs11140851 9 87703126 [A/G] rs630426 9 87704881 [A/G] rs1809699 9 87705388 [A/G] rs7044762 9 87707585 [A/G] rs7034839 9 87710734 [A/C] rs622445 9 87718566 [A/G] rs4877295 9 87726012 [T/C] rs7868560 9 87728550 [T/G] rs902396 9 87744368 [A/G] rs7852361 9 87752417 [T/C] rs10116398 9 87757443 [A/G] rs7865394 9 87759067 [T/C] rs10868257 9 87761907 [T/C] rs6559849 9 87766276 [A/G] rs1931101 9 87769185 [A/G] rs12004450 9 87769748 [T/C] rs496239 9 87771842 [T/G] rs526454 9 87772807 [A/G] rs620420 9 87778956 [T/C] rs665889 9 87782211 [T/C] rs4877909 9 87784527 [T/C] rs4877910 9 87785672 [T/C] rs1387927 9 87788048 [A/G] rs13289484 9 87788660 [T/G] rs329200 9 87795226 [A/G] rs1887618 9 87796745 [A/G] rs329202 9 87799182 [T/C] rs329219 9 87802989 [A/G] rs329206 9 87806205 [A/G] rs329209 9 87808147 [T/C] rs11140885 9 87808253 [T/C] rs752184 9 87811640 [T/C] rs7850866 9 87820596 [A/G] rs1931114 9 87822415 [A/C] rs1931093 9 87832469 [A/G] rs11140892 9 87834342 [T/C] rs7030902 9 87835091 [A/G] rs11140900 9 87844016 [T/C] rs1931094 9 87844548 [A/G] rs11140902 9 87845035 [T/C] rs766348 9 87847392 [A/G] rs7868742 9 87849648 [A/G] rs7018725 9 87855507 [A/G] rs913444 9 87861650 [A/G] rs7862326 9 87864354 [A/G] rs10122948 9 87875615 [A/G] rs1927605 9 87877165 [T/C] rs2841502 9 87890350 [T/C] rs1927602 9 87892071 [A/C] rs10118819 9 87893574 [T/C] rs2841445 9 87897177 [A/C] rs2841473 9 87903467 [T/G] rs2769612 9 87909739 [T/C] rs17088419 9 87910924 [T/C] rs1983944 9 87917458 [T/C] rs4877913 9 87922664 [A/G] rs2841486 9 87926046 [A/G] rs12551160 9 87928035 [A/G] rs2841498 9 87930045 [A/C] rs2841500 9 87930294 [A/C] rs7029815 9 87930435 [A/G] rs7026075 9 87937563 [T/C] rs6559860 9 87944048 [T/C] rs4877915 9 87948558 [T/G] rs4439204 9 87952694 [A/G] rs4877920 9 87960028 [A/G] rs7030964 9 87966658 [T/C] rs10122851 9 87983336 [A/G] rs12004989 9 87984163 [T/C] rs2814734 9 87992789 [A/C] rs7860844 9 87994507 [A/C] rs2814737 9 87995971 [T/C] rs2841443 9 87996304 [A/G] rs2592991 9 88000506 [A/C] rs895606 9 88003668 [A/G] rs17425572 9 88006338 [A/G] rs1867957 9 88009872 [A/C] rs1867956 9 88009912 [A/G] rs1447029 9 88010388 [T/C] rs1447027 9 88011840 [A/G] rs1374507 9 88012713 [T/C] rs2841451 9 88013822 [A/G] rs2593016 9 88013998 [T/G] rs2841452 9 88014485 [A/C] rs2841454 9 88015543 [T/C] rs12685505 9 88017606 [T/C] rs4877928 9 88018061 [A/G] rs2841455 9 88018856 [T/G] rs10512167 9 88024130 [A/G] rs2814732 9 88031251 [A/G] rs12236186 9 88042156 [T/C] rs13292809 9 88043188 [A/G] rs17088670 9 88043476 [A/G] rs7028056 9 88043805 [T/C] rs10868292 9 88044756 [T/C] rs2256555 9 88047238 [A/G] rs2593005 9 88055204 [A/C] rs11140970 9 88059730 [T/G] rs11140975 9 88069076 [A/C] rs12553871 9 88069314 [A/C] rs11140976 9 88070889 [T/C] rs10868296 9 88071696 [A/G] rs6559867 9 88086685 [A/G] rs11140985 9 88087511 [T/C] rs10868306 9 88098058 [T/C] rs11140989 9 88098490 [T/C] rs1992812 9 88099866 [T/C] rs7042753 9 88101673 [T/C] rs1447025 9 88104161 [T/G] rs10114046 9 88105301 [A/G] rs9314742 9 88111373 [A/G] rs7041064 9 88113727 [A/G] rs10512168 9 88116256 [A/G] rs876927 9 88117073 [T/G] rs4588941 9 88118172 [A/G] rs935466 9 88118237 [A/G] rs7854574 9 88122906 [A/G] rs7043100 9 88122937 [T/C] rs3860946 9 88123347 [A/G] rs10115062 9 88123838 [T/C] rs10746763 9 88131557 [A/C] rs12343187 9 88133513 [A/G] rs1250792 9 88137639 [A/G] rs11141010 9 88138617 [A/G] rs10780727 9 88140497 [T/G] rs7032476 9 88141571 [A/G] rs7850808 9 88143119 [T/C] rs2278111 9 88149101 [T/C] rs883916 9 88149430 [A/G] rs7863811 9 88149573 [A/G] rs7863713 9 88153227 [T/C] rs17088766 9 88154909 [A/G] rs2059403 9 88154941 [A/G] rs11141016 9 88159352 [A/C] rs17349624 9 88160238 [T/C] rs11141018 9 88164213 [A/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs10780728 9 88167035 [A/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs10120410 9 88171820 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs10780729 9 88180032 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs10115559 9 88191184 [T/G] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs4645620 9 88204998 [T/G] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs1469202 9 88205819 [A/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs1571119 9 88215534 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs1819284 9 88226038 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs618242 9 88234954 [A/G] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs10117805 9 88242953 [A/G] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs590506 9 88244337 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs12346022 9 88251643 [A/G] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs7031647 9 88277116 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs4877947 9 88279039 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs9314744 9 88279765 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs10868338 9 88299460 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs10283836 9 88307525 [A/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs7863248 9 88308127 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs17429447 9 88313539 [A/G] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs1359712 9 88316886 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs10780740 9 88331840 [T/G] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs7025831 9 88339287 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs4877950 9 88340454 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs12001865 9 88345661 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs10868342 9 88351591 [A/G] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs3916184 9 88353231 [T/C] NM_001286715,NM_015239,NM_001330701,NM_001286717 AGTPBP1,AGTPBP1,AGTPBP1,AGTPBP1 Silent,Silent,Silent,Silent rs3812508 9 88357495 [A/G] rs10868345 9 88371919 [T/G] rs12350310 9 88396422 [A/G] rs7868234 9 88455523 [A/G] NR_029410 LOC389765 Silent rs7043567 9 88460986 [A/G] rs7018466 9 88477869 [T/C] rs7847160 9 88487479 [A/G] rs7044503 9 88515756 [A/G] rs7039482 9 88518441 [T/G] rs11141141 9 88520203 [T/C] rs11141146 9 88521040 [T/C] rs570516 9 88530006 [T/C] rs2770831 9 88530616 [T/G] rs645063 9 88533596 [A/G] rs12552584 9 88533866 [A/G] rs483334 9 88538024 [A/G] rs649213 9 88538154 [T/C] rs10512169 9 88540410 [T/C] rs7854481 9 88552282 [T/C] rs11141155 9 88558068 [T/C] NM_001321881,NM_024635,NM_001321882 NAA35,NAA35,NAA35 Silent,Silent,Silent rs11141156 9 88560387 [T/G] NM_001321881,NM_024635,NM_001321882 NAA35,NAA35,NAA35 Silent,Silent,Silent rs954124 9 88563064 [A/G] NM_001321881,NM_024635,NM_001321882 NAA35,NAA35,NAA35 Silent,Silent,Silent rs13296057 9 88567760 [T/C] NM_001321881,NM_024635,NM_001321882 NAA35,NAA35,NAA35 Silent,Silent,Silent rs11141165 9 88585014 [T/C] NM_001321881,NM_024635,NM_001321882 NAA35,NAA35,NAA35 Silent,Silent,Silent rs10868357 9 88597262 [A/C] NM_001321881,NM_024635,NM_001321882 NAA35,NAA35,NAA35 Silent,Silent,Silent rs4877955 9 88605205 [T/G] NM_001321881,NM_024635,NM_001321882 NAA35,NAA35,NAA35 Silent,Silent,Silent rs10868362 9 88634662 [T/C] NM_001321881,NM_024635,NM_001321882 NAA35,NAA35,NAA35 Silent,Silent,Silent rs3750388 9 88637980 [T/G] NM_001321882 NAA35 EXON Silent rs4877959 9 88646703 [A/G] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs7046093 9 88650029 [T/C] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs12350451 9 88661486 [A/G] NM_016548,NM_177937 GOLM1,GOLM1 EXON Synonymous_D122D,Synonymous_D122D rs7031120 9 88669475 [T/G] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs10115014 9 88671087 [T/C] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs7865836 9 88679834 [A/C] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs7866281 9 88679955 [A/G] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs4333693 9 88692049 [A/C] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs3750390 9 88692336 [T/C] NM_016548,NM_177937 GOLM1,GOLM1 EXON Synonymous_Q100Q,Synonymous_Q100Q rs2183126 9 88692838 [A/G] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs7019241 9 88693460 [T/C] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs10125666 9 88693763 [A/G] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs957617 9 88698673 [T/C] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs1928228 9 88698820 [T/G] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs10868366 9 88700060 [T/G] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs10868372 9 88707692 [T/C] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs4338185 9 88709573 [A/G] NM_016548,NM_177937 GOLM1,GOLM1 Silent,Silent rs2225237 9 88715004 [A/G] NM_177937 GOLM1 EXON Silent rs7854401 9 88721252 [T/C] rs7875522 9 88729691 [T/C] rs7870214 9 88733933 [A/G] rs2770811 9 88738450 [T/C] rs10115513 9 88741540 [A/G] rs2812003 9 88743556 [A/G] NR_110996 LOC101927623 EXON Silent rs12343938 9 88748382 [T/C] NR_110996 LOC101927623 Silent rs12378988 9 88755951 [T/C] NR_110996 LOC101927623 Silent rs11141262 9 88756246 [T/C] NR_110996 LOC101927623 Silent rs11507200 9 88766713 [A/G] NR_110996 LOC101927623 Silent rs12002764 9 88778654 [T/C] rs4620358 9 88782362 [A/G] rs11141283 9 88784346 [A/G] rs7855538 9 88790268 [A/C] rs4877963 9 88794032 [T/G] rs1359170 9 88800714 [A/C] rs7028601 9 88800728 [A/G] rs7847143 9 88811119 [T/C] rs10868394 9 88824018 [A/G] rs6559913 9 88825873 [A/G] rs4316216 9 88833465 [A/G] rs7036724 9 88836286 [T/C] NM_001276366,NM_001276367,NM_001276368 C9orf153,C9orf153,C9orf153 EXON Silent,Silent,Silent rs1002960 9 88839915 [A/C] NM_001276366,NM_001276367,NM_001276368 C9orf153,C9orf153,C9orf153 Silent,Silent,Silent rs11141306 9 88844634 [T/G] NM_001276366,NM_001276367,NM_001276368 C9orf153,C9orf153,C9orf153 Silent,Silent,Silent rs942284 9 88847477 [T/C] NM_001276366,NM_001276367,NM_001276368 C9orf153,C9orf153,C9orf153 Silent,Silent,Silent rs10118760 9 88854546 [T/G] NM_001276366,NM_001276367,NM_001276368 C9orf153,C9orf153,C9orf153 Silent,Silent,Silent rs6559918 9 88856534 [A/G] NM_001276366,NM_001276367,NM_001276368 C9orf153,C9orf153,C9orf153 Silent,Silent,Silent rs10125093 9 88857199 [T/C] NM_001276366,NM_001276367,NM_001276368 C9orf153,C9orf153,C9orf153 Silent,Silent,Silent rs7848944 9 88859144 [T/C] NM_001276366,NM_001276367,NM_001276368 C9orf153,C9orf153,C9orf153 Silent,Silent,Silent rs12342629 9 88860336 [T/C] NM_001276366,NM_001276367,NM_001276368 C9orf153,C9orf153,C9orf153 Silent,Silent,Silent rs4484780 9 88860820 [T/C] NM_001276366,NM_001276367,NM_001276368 C9orf153,C9orf153,C9orf153 Silent,Silent,Silent rs11791066 9 88869630 [T/C] NM_001276366,NM_001276367,NM_001276368 C9orf153,C9orf153,C9orf153 Silent,Silent,Silent rs1547629 9 88870898 [T/C] NM_001276366,NM_001276367,NM_001276368 C9orf153,C9orf153,C9orf153 Silent,Silent,Silent rs1061946 9 88874117 [A/G] NM_001276366,NM_001276367 C9orf153,C9orf153 Silent,Silent rs4877966 9 88877447 [T/G] rs10780756 9 88902165 [A/G] rs10868406 9 88906695 [G/C] NM_001185059,NM_001330718,NM_024617,NM_001185074 TUT7,TUT7,TUT7,TUT7 Silent,Silent,Silent,Silent rs4587414 9 88910161 [T/C] NM_001185059,NM_001330718,NM_024617,NM_001185074 TUT7,TUT7,TUT7,TUT7 Silent,Silent,Silent,Silent rs10115526 9 88914554 [T/G] NM_001185059,NM_001330718,NM_024617,NM_001185074 TUT7,TUT7,TUT7,TUT7 Silent,Silent,Silent,Silent rs4877314 9 88919453 [T/C] NM_001185059,NM_001330718,NM_024617,NM_001185074 TUT7,TUT7,TUT7,TUT7 Silent,Silent,Silent,Silent rs7028494 9 88926377 [A/G] NM_001185059,NM_001330718,NM_024617,NM_001185074 TUT7,TUT7,TUT7,TUT7 Silent,Silent,Silent,Silent rs700759 9 88933672 [A/G] NM_001185059,NM_001330718,NM_024617,NM_001185074 TUT7,TUT7,TUT7,TUT7 Silent,Silent,Silent,Silent rs791313 9 88942674 [A/G] NM_001185059,NM_001330718,NM_024617,NM_001185074 TUT7,TUT7,TUT7,TUT7 Silent,Silent,Silent,Silent rs7041214 9 88943005 [T/C] NM_001185059,NM_001330718,NM_024617,NM_001185074 TUT7,TUT7,TUT7,TUT7 Silent,Silent,Silent,Silent rs10512175 9 88952313 [A/C] NM_001185059,NM_001330718,NM_024617,NM_001185074 TUT7,TUT7,TUT7,TUT7 Silent,Silent,Silent,Silent rs791323 9 88959938 [T/C] NM_001185059,NM_001330718,NM_024617,NM_001185074 TUT7,TUT7,TUT7,TUT7 EXON Synonymous_L317L,Silent,Synonymous_L317L,Synonymous_L317L rs17461620 9 88963008 [T/C] NM_001185059,NM_001330718,NM_024617,NM_001185074 TUT7,TUT7,TUT7,TUT7 Silent,Silent,Silent,Silent rs12115483 9 88975529 [T/C] rs4877971 9 88985734 [A/G] rs1114706 9 88999220 [T/G] rs11141370 9 89000219 [T/C] rs10868424 9 89001745 [T/C] rs6559926 9 89011328 [A/G] rs187136 9 89011615 [T/C] rs13284082 9 89022298 [T/C] rs11141381 9 89023508 [A/G] rs10868434 9 89025919 [T/C] rs353806 9 89026453 [A/C] rs353807 9 89026538 [T/C] rs187117 9 89029703 [T/C] rs416513 9 89030832 [T/G] rs17051878 9 89030908 [A/C] rs2889968 9 89031511 [A/G] rs806269 9 89031729 [T/C] rs11792677 9 89033309 [T/C] rs12340673 9 89035352 [A/G] rs1331844 9 89035754 [A/C] rs17051885 9 89035877 [A/G] rs354815 9 89036027 [T/C] rs1041526 9 89040610 [A/G] rs11141391 9 89041277 [T/G] rs1576728 9 89042419 [A/G] rs4877980 9 89046282 [A/G] rs184789 9 89051246 [T/C] rs189544 9 89057171 [A/G] rs410206 9 89058963 [A/G] rs9314753 9 89059014 [A/C] rs7851100 9 89060516 [T/G] rs12339414 9 89061787 [A/G] rs7038873 9 89062045 [A/G] rs1929802 9 89063984 [T/C] rs353826 9 89066329 [T/C] rs4877981 9 89066515 [T/C] rs12344100 9 89067372 [T/C] rs12346290 9 89068546 [T/G] rs12346362 9 89068752 [T/C] rs353828 9 89071733 [T/C] rs11141409 9 89071996 [T/C] rs353834 9 89073689 [A/G] rs7026472 9 89074684 [T/G] rs460811 9 89081586 [A/G] rs750186 9 89086425 [A/G] rs432957 9 89086848 [T/C] rs653030 9 89102306 [T/G] rs168493 9 89107564 [T/C] rs6559931 9 89115887 [T/C] rs7341859 9 89117014 [A/G] rs7029017 9 89126786 [A/G] rs4877322 9 89134626 [T/G] rs2148996 9 89142905 [T/G] rs7863336 9 89146457 [A/G] rs1023003 9 89147815 [A/G] rs1023004 9 89147852 [A/G] rs11792704 9 89148945 [T/C] rs7861642 9 89149329 [T/C] rs2065376 9 89157066 [A/G] rs1331433 9 89160794 [T/G] rs10491846 9 89162181 [T/C] rs10780767 9 89162323 [A/G] rs12551728 9 89166936 [T/C] rs962704 9 89167524 [T/C] rs1331436 9 89168700 [A/G] rs913357 9 89172482 [T/C] rs10868444 9 89174807 [T/C] rs17051989 9 89174943 [T/G] rs7850197 9 89177743 [A/G] rs1537190 9 89178164 [T/C] rs7026807 9 89178987 [A/G] rs2065378 9 89188290 [A/C] rs10780771 9 89191784 [A/G] rs10117819 9 89193482 [T/C] rs2183731 9 89199480 [T/G] rs2183732 9 89199498 [T/C] rs2860107 9 89212523 [T/G] rs7852670 9 89213659 [T/C] rs985863 9 89219411 [A/G] rs868823 9 89219781 [A/G] rs11141456 9 89227561 [T/C] rs10868451 9 89227755 [A/G] rs12343626 9 89230485 [A/G] rs9696070 9 89230779 [T/C] rs9695351 9 89236894 [A/G] rs4492454 9 89240136 [A/G] rs1888713 9 89240189 [A/G] rs1888714 9 89240203 [A/G] rs914394 9 89245979 [A/G] rs7851559 9 89246924 [T/C] rs1331453 9 89248754 [A/G] rs10512176 9 89252706 [T/C] rs35193745 9 89263961 [T/C] rs1411987 9 89269078 [A/G] rs11141473 9 89269261 [A/C] rs4877995 9 89271532 [T/G] rs2183730 9 89271591 [T/C] rs12683318 9 89274201 [A/G] rs7869597 9 89275786 [A/C] rs12345686 9 89278196 [A/C] rs4877329 9 89278227 [A/G] rs7853196 9 89279055 [T/C] rs932956 9 89280867 [A/G] rs11141481 9 89282468 [T/C] rs7860045 9 89285932 [A/G] rs11141482 9 89286335 [A/C] rs6559946 9 89287374 [A/C] rs1929463 9 89290300 [A/G] rs11141486 9 89293393 [A/G] rs10868464 9 89296599 [T/G] rs10868467 9 89297754 [T/G] rs10868469 9 89302560 [A/C] rs1475617 9 89305431 [T/C] rs11141494 9 89306305 [A/G] rs10780781 9 89308609 [A/C] rs4878002 9 89309429 [T/C] rs1029046 9 89314179 [T/C] rs1331443 9 89315229 [T/C] rs7032797 9 89316235 [A/G] rs10746782 9 89317479 [A/G] rs1927642 9 89321913 [A/C] rs755056 9 89323257 [A/C] rs7047160 9 89327965 [T/C] rs2378715 9 89331137 [A/G] rs4878010 9 89336987 [T/C] rs12348171 9 89345014 [T/C] rs7864375 9 89347214 [T/C] rs10046817 9 89351232 [A/G] rs932858 9 89351788 [T/C] rs1571333 9 89356423 [A/G] rs4877333 9 89365547 [T/C] rs11141530 9 89365622 [A/G] rs10514832 9 89368334 [A/G] rs2274558 9 89371743 [T/C] rs2274559 9 89372582 [A/G] rs2274561 9 89372790 [A/G] rs994029 9 89375314 [T/C] rs10868482 9 89377344 [T/G] rs10746786 9 89378267 [A/G] rs11141538 9 89378977 [A/G] rs12351577 9 89382631 [A/G] rs12338073 9 89382759 [T/C] rs7043314 9 89394222 [T/C] rs7852002 9 89402003 [T/C] rs1328175 9 89402721 [T/G] rs7036971 9 89404665 [A/G] rs7851591 9 89408927 [A/C] rs10514834 9 89415661 [T/C] rs7048294 9 89419847 [T/C] rs374503 9 89422169 [T/C] rs4877337 9 89429681 [A/G] rs12236362 9 89429897 [A/G] rs452723 9 89432027 [T/G] rs11141559 9 89436746 [A/G] rs10868488 9 89437343 [T/C] rs4878016 9 89439307 [A/G] rs4242637 9 89440597 [A/G] rs10868490 9 89440695 [T/C] rs10780795 9 89443026 [T/C] rs11141567 9 89443078 [A/C] rs1028880 9 89444725 [A/G] rs1977459 9 89445581 [A/G] rs10780796 9 89448000 [T/C] rs7021048 9 89453847 [T/C] rs10746789 9 89456443 [A/G] rs7032556 9 89468654 [A/G] rs13302123 9 89472439 [T/C] rs7048161 9 89474289 [T/C] rs10868498 9 89478860 [A/G] rs1169848 9 89481996 [T/G] rs1328169 9 89484280 [A/G] rs10868499 9 89488447 [A/G] rs7018734 9 89501366 [A/G] rs10868500 9 89505042 [T/C] rs12352609 9 89505232 [T/C] rs10780800 9 89509444 [T/G] rs10868502 9 89512335 [T/C] rs7021050 9 89514067 [A/C] rs10512177 9 89519033 [T/C] rs10780802 9 89521299 [T/G] rs11141591 9 89525066 [A/G] rs11141592 9 89525449 [A/G] rs11141607 9 89530641 [T/C] rs7036455 9 89554097 [T/C] rs12350534 9 89558064 [T/C] rs12342165 9 89561919 [T/C] NM_002048 GAS1 EXON Silent rs1927081 9 89567590 [A/G] NR_049794 GAS1RR Silent rs10868508 9 89570731 [T/C] NR_049794 GAS1RR Silent rs9792548 9 89573083 [A/G] NR_049794 GAS1RR Silent rs12555168 9 89574128 [T/C] NR_049794 GAS1RR Silent rs7034424 9 89574902 [T/C] NR_049794 GAS1RR Silent rs1927084 9 89575478 [A/G] NR_049794 GAS1RR Silent rs7862522 9 89575529 [T/C] NR_049794 GAS1RR Silent rs10119026 9 89576961 [T/G] NR_049794 GAS1RR Silent rs7849517 9 89579246 [A/C] NR_049794 GAS1RR Silent rs11141634 9 89579576 [A/G] NR_049794 GAS1RR Silent rs12555841 9 89584572 [A/G] NR_049794 GAS1RR Silent rs10448319 9 89589210 [T/G] NR_049794 GAS1RR Silent rs12379195 9 89593328 [A/G] NR_049794 GAS1RR Silent rs11141638 9 89593967 [A/G] NR_049794 GAS1RR Silent rs4878029 9 89594294 [A/G] NR_049794 GAS1RR Silent rs10114955 9 89597085 [T/C] NR_049794 GAS1RR Silent rs7047338 9 89600651 [A/G] NR_049794 GAS1RR Silent rs6559958 9 89605153 [T/C] NR_049794 GAS1RR Silent rs1927070 9 89606711 [T/C] NR_049794 GAS1RR Silent rs13296748 9 89606981 [T/C] NR_049794 GAS1RR Silent rs10868521 9 89607073 [T/C] NR_049794 GAS1RR Silent rs10868522 9 89607469 [A/G] NR_049794 GAS1RR Silent rs4493983 9 89608864 [A/C] NR_049794 GAS1RR Silent rs7863740 9 89614276 [T/C] NR_049794 GAS1RR EXON Silent rs7031306 9 89619991 [T/C] rs1927087 9 89620854 [A/G] rs17052425 9 89622864 [A/G] rs12375908 9 89627102 [T/C] NR_027471 LOC440173 Silent rs7022771 9 89627369 [A/C] NR_027471 LOC440173 Silent rs12553476 9 89633112 [A/G] NR_027471 LOC440173 Silent rs2045536 9 89636829 [T/C] NR_027471 LOC440173 Silent rs1599045 9 89641577 [T/C] NR_027471 LOC440173 Silent rs7873337 9 89650543 [T/C] NR_027471 LOC440173 Silent rs6559962 9 89652307 [T/C] NR_027471 LOC440173 Silent rs7023578 9 89655363 [A/G] NR_027471 LOC440173 Silent rs7870183 9 89655704 [T/C] NR_027471 LOC440173 Silent rs4242638 9 89670005 [A/G] rs4878036 9 89670188 [T/C] rs13302497 9 89673000 [A/G] rs17382423 9 89673026 [T/C] rs7873966 9 89678531 [A/G] rs4878043 9 89687854 [T/C] rs1028863 9 89688153 [A/G] rs10125983 9 89696011 [T/C] rs13292789 9 89704509 [A/G] rs1012593 9 89709884 [T/C] rs7863730 9 89711103 [T/G] rs10122325 9 89711358 [A/G] rs7858361 9 89722325 [T/G] rs7874988 9 89726511 [T/C] rs7045583 9 89737701 [A/G] rs10115421 9 89738445 [T/G] rs277742 9 89745271 [T/G] rs277736 9 89753471 [A/C] rs277733 9 89754133 [A/G] rs13295659 9 89763278 [T/C] rs166750 9 89765887 [A/G] NM_001001709 C9orf170 Silent rs277763 9 89766465 [T/C] NM_001001709 C9orf170 Silent rs463064 9 89772284 [A/G] NM_001001709 C9orf170 EXON Silent rs277755 9 89772413 [A/C] NM_001001709 C9orf170 EXON Silent rs277754 9 89772708 [T/C] NM_001001709 C9orf170 EXON Silent rs277753 9 89773016 [T/C] NM_001001709 C9orf170 EXON Silent rs277750 9 89775429 [A/G] rs7868122 9 89777497 [T/C] rs277747 9 89782806 [A/G] rs277722 9 89801126 [A/G] rs277714 9 89803351 [T/C] rs12554839 9 89809139 [T/G] rs1885782 9 89817082 [A/G] rs427361 9 89820895 [A/G] rs373546 9 89821219 [T/C] rs12336476 9 89821983 [T/G] rs450652 9 89824013 [A/G] rs12235447 9 89827518 [A/G] rs278709 9 89833267 [A/G] rs7863624 9 89836173 [A/G] rs17052579 9 89838126 [T/C] rs10113878 9 89843781 [A/G] rs11141716 9 89844462 [T/G] rs2031126 9 89844907 [A/G] rs10465182 9 89845133 [T/C] rs10512182 9 89849237 [T/C] rs11141719 9 89854486 [T/C] rs7862236 9 89854595 [T/G] rs10122994 9 89858267 [A/G] rs7026586 9 89862258 [A/G] rs12348439 9 89869968 [T/C] rs10868546 9 89872124 [T/G] rs7024533 9 89873773 [T/C] rs7025731 9 89874518 [A/G] rs1969763 9 89874893 [T/G] rs1969762 9 89874932 [A/G] rs1570421 9 89878104 [T/C] rs4877347 9 89880234 [A/G] rs7859923 9 89888137 [A/G] rs2889975 9 89890786 [A/G] rs10125155 9 89893787 [T/C] rs7041849 9 89898642 [T/C] rs7020248 9 89902954 [T/C] rs1923797 9 89903208 [A/G] rs7020618 9 89903221 [T/C] rs4878051 9 89905542 [T/C] rs4878052 9 89905888 [T/C] rs10746796 9 89910813 [T/C] rs17472787 9 89917347 [A/G] rs1885783 9 89919913 [T/G] rs944655 9 89922395 [T/C] rs7858308 9 89922889 [T/G] rs10868554 9 89924306 [A/G] rs10868555 9 89924898 [A/C] rs10780823 9 89931500 [T/G] rs1923789 9 89934837 [A/C] rs4878057 9 89936504 [A/C] rs1923786 9 89939154 [T/C] rs6559979 9 89940123 [T/C] rs1923783 9 89941523 [T/G] rs10780825 9 89942866 [A/C] rs10868558 9 89944405 [A/G] rs7026815 9 89946647 [T/C] rs7874448 9 89951180 [T/G] rs1888924 9 89951915 [T/G] rs11141752 9 89954522 [A/G] rs4878060 9 89955458 [T/G] rs11141754 9 89958743 [A/G] rs1923782 9 89959135 [T/C] rs4877351 9 89959906 [T/C] rs4878063 9 89961029 [T/C] rs912067 9 89961776 [T/C] rs1923800 9 89963474 [A/G] rs4878066 9 89965089 [T/G] rs10746798 9 89967335 [T/G] rs10868564 9 89967771 [T/C] rs1930056 9 89970895 [T/G] rs1930057 9 89979884 [T/C] rs2378733 9 89985014 [A/G] rs7861579 9 89985250 [T/G] rs11141771 9 89991119 [T/C] rs1958938 9 89996566 [T/G] rs10125807 9 89997130 [A/G] rs1930055 9 90001560 [T/C] rs10868569 9 90002875 [A/G] rs12376350 9 90002911 [T/C] rs4878073 9 90004329 [A/G] rs4144392 9 90006563 [A/G] rs10868572 9 90007371 [A/G] rs1958937 9 90007462 [A/G] rs7044399 9 90008584 [A/C] rs12344505 9 90012840 [T/C] rs10746805 9 90013672 [T/C] rs10780833 9 90013698 [T/G] rs4878075 9 90018842 [A/G] rs7039493 9 90020128 [A/G] rs10746806 9 90034195 [A/G] rs2183939 9 90034729 [T/C] rs2314 9 90036219 [T/C] rs4579610 9 90041160 [T/C] rs7870463 9 90043880 [A/G] rs6559987 9 90045801 [T/G] rs7025941 9 90046983 [T/C] rs4878077 9 90049204 [A/G] rs10512185 9 90051391 [T/C] rs10868585 9 90052125 [T/C] rs2149809 9 90052537 [T/C] rs10780837 9 90054710 [A/G] rs10868588 9 90054745 [A/G] rs11141813 9 90063194 [T/C] rs10868592 9 90066956 [T/C] rs17475756 9 90067655 [A/G] rs10124291 9 90068509 [T/C] rs7849703 9 90073584 [T/C] rs1928474 9 90079395 [A/G] rs4457416 9 90081038 [A/G] rs1411090 9 90085205 [T/G] rs10780842 9 90095024 [T/G] rs10868605 9 90095233 [T/C] rs2094707 9 90098265 [A/G] rs11141844 9 90101096 [T/C] rs7043393 9 90101620 [A/G] rs3758308 9 90110124 [T/C] rs2058882 9 90114746 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs11141855 9 90119401 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs7855878 9 90123213 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs10125534 9 90125129 [T/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs10122321 9 90125146 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs1475524 9 90132563 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs1556 9 90133673 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs17399090 9 90135027 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs1105384 9 90136246 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs871495 9 90137616 [T/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs10780849 9 90137909 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs10746816 9 90138130 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs11141862 9 90139441 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs17477673 9 90140505 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs11793890 9 90142383 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs4878089 9 90143575 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs11998833 9 90145334 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs10512186 9 90145381 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs7040394 9 90146658 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs12686192 9 90148464 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3028 9 90151362 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs4877365 9 90155692 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs1014306 9 90157451 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs7036781 9 90159903 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs7036598 9 90160010 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs12378686 9 90163570 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs7866648 9 90165926 [A/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs1983973 9 90168002 [T/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs11141878 9 90169540 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs6560001 9 90170231 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs10512187 9 90170885 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs11141879 9 90170988 [T/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs7852430 9 90171408 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs17479142 9 90172040 [A/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs1861832 9 90174169 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs1571515 9 90177252 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs12001404 9 90178124 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs888336 9 90179619 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs9314763 9 90183367 [A/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs12340431 9 90184453 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3128519 9 90186205 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs11141899 9 90186976 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs4878104 9 90192991 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs888333 9 90195672 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs4877367 9 90198251 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs7043056 9 90202347 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs17053163 9 90203221 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs1473180 9 90206006 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs17053193 9 90208532 [A/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3095748 9 90209137 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs12551072 9 90210508 [T/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3124236 9 90211490 [A/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3739784 9 90216094 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3124237 9 90218218 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs7027958 9 90218347 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3095747 9 90218678 [T/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs13288561 9 90220370 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs11141911 9 90223085 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs2111554 9 90224267 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs1015477 9 90225414 [A/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs4877368 9 90229573 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs7869944 9 90232402 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs11141914 9 90234714 [A/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs13283404 9 90235142 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs11141915 9 90235794 [A/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs4878112 9 90240377 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3095755 9 90240813 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs10746822 9 90242810 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3124238 9 90246317 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs1861829 9 90250053 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs2378753 9 90258153 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs1927976 9 90258633 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs2274609 9 90260556 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3118867 9 90261695 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs2274606 9 90262425 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3118870 9 90264023 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3818584 9 90265015 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 EXON Synonymous_D536D,Synonymous_D536D,Synonymous_D536D,Synonymous_D536D rs10868642 9 90265697 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3128471 9 90274869 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs11141934 9 90276666 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3118848 9 90278786 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs12335796 9 90280569 [T/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs10115182 9 90282249 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs721936 9 90283149 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3750539 9 90283509 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3750538 9 90283514 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 EXON Synonymous_D642D,Synonymous_D642D,Synonymous_D642D,Synonymous_D642D rs11141937 9 90284962 [T/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs4878117 9 90285464 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs10868644 9 90289936 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3118850 9 90290816 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3118851 9 90291121 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs11141941 9 90291303 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3118853 9 90293349 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3128479 9 90297680 [A/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs1927971 9 90307057 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3128489 9 90308000 [T/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3128494 9 90312577 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs2274601 9 90313449 [T/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs7025760 9 90317668 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3793647 9 90318855 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3793646 9 90319365 [T/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3118862 9 90319906 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs1927973 9 90320954 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 Silent,Silent,Silent,Silent rs3118863 9 90321583 [T/C] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 EXON Synonymous_R1199R,Synonymous_R1199R,Synonymous_R1199R,Synonymous_R1199R rs1056719 9 90322023 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 EXON Missense_S1346N,Missense_S1346N,Missense_S1346N,Missense_S1346N rs13283425 9 90323220 [A/G] NM_001288731,NM_001288730,NM_004938,NM_001288729 DAPK1,DAPK1,DAPK1,DAPK1 EXON Silent,Silent,Silent,Silent rs7028853 9 90323587 [T/C] rs3118866 9 90324200 [A/G] rs4877369 9 90324869 [T/C] rs3128499 9 90327095 [A/G] rs4877370 9 90328478 [A/G] rs3128506 9 90334530 [T/C] rs3118869 9 90340863 [A/C] rs2378757 9 90343780 [A/C] NM_001257972,NM_001912,NM_001257973,NM_145918,NM_001257971 CTSL,CTSL,CTSL,CTSL,CTSL Silent,Silent,Silent,Silent,Silent rs2296958 9 90344316 [T/C] NM_001257972,NM_001912,NM_001257973,NM_145918,NM_001257971 CTSL,CTSL,CTSL,CTSL,CTSL Silent,Silent,Silent,Silent,Silent rs3128511 9 90347450 [T/G] rs7870268 9 90355120 [T/G] rs3118839 9 90362777 [T/C] rs3118840 9 90363086 [A/G] rs1927982 9 90364627 [T/C] rs17053425 9 90365913 [A/G] rs10780872 9 90366905 [A/G] rs9410948 9 90366947 [T/G] rs9410619 9 90368104 [T/C] rs2149383 9 90370106 [T/G] rs943856 9 90370511 [T/C] rs4598339 9 90380485 [T/C] rs4878122 9 90383163 [A/G] rs9410624 9 90384418 [T/C] rs7037401 9 90387296 [T/G] rs9285055 9 90390559 [A/G] NR_027917 CTSL3P Silent rs4878130 9 90392042 [A/G] NR_027917 CTSL3P Silent rs7848164 9 90392406 [A/C] NR_027917 CTSL3P Silent rs10123732 9 90395684 [A/G] NR_027917 CTSL3P Silent rs9410632 9 90400909 [T/C] NR_027917 CTSL3P Silent rs7866968 9 90401796 [A/G] NR_027917 CTSL3P EXON Silent rs6560027 9 90401861 [A/G] rs4878132 9 90403094 [T/G] rs12684240 9 90404087 [A/G] rs9410964 9 90405210 [A/C] rs7039252 9 90408599 [A/G] rs7044255 9 90410305 [T/C] rs9410636 9 90425335 [T/C] rs6420260 9 90428537 [A/G] rs11141976 9 90431177 [A/G] rs11141977 9 90432159 [A/G] rs7867409 9 90432515 [A/G] rs11794730 9 90440658 [T/G] rs11141981 9 90442020 [T/C] rs7025119 9 90448266 [T/C] rs10116815 9 90450644 [T/C] rs7850237 9 90453619 [T/C] rs7045334 9 90455686 [T/C] rs7018666 9 90462253 [A/G] NR_033405 CTSLP8 EXON Silent rs11141992 9 90466696 [A/C] rs3935944 9 90470780 [A/G] rs11142008 9 90481245 [T/C] rs10868664 9 90482495 [A/G] rs12001141 9 90487391 [T/C] NR_149022 LOC497256 Silent rs4072799 9 90487924 [T/G] NR_149022 LOC497256 Silent rs10868668 9 90493423 [T/C] NR_149022 LOC497256 Silent rs10780878 9 90494889 [T/G] NR_149022 LOC497256 Silent rs6560041 9 90495370 [T/C] NR_149022 LOC497256 Silent rs12346877 9 90496987 [T/C] NR_149022 LOC497256 Silent rs7850542 9 90500405 [A/C] NR_149022,NM_178828 LOC497256,SPATA31E1 EXON Silent,Missense_T335P rs4076795 9 90501448 [A/C] NR_149022,NM_178828 LOC497256,SPATA31E1 EXON Silent,Missense_D682E rs11142017 9 90503451 [A/G] NR_149022,NM_178828 LOC497256,SPATA31E1 EXON Silent,Missense_R1350H rs12238266 9 90503734 [T/C] NR_149022,NM_178828 LOC497256,SPATA31E1 EXON Silent,Synonymous_A1444A rs12553713 9 90512396 [A/G] NR_149022 LOC497256 Silent rs12552120 9 90514482 [T/C] NR_149022 LOC497256 Silent rs7470248 9 90515619 [A/G] NR_149022 LOC497256 Silent rs472627 9 90570335 [T/C] rs655500 9 90571740 [T/G] rs668108 9 90581425 [A/G] NM_001170640,NM_001170639,NM_012119,NM_001039803,NM_178432 CDK20,CDK20,CDK20,CDK20,CDK20 EXON Silent,Silent,Silent,Silent,Silent rs1167 9 90581746 [T/C] NM_001170640,NM_001170639,NM_012119,NM_001039803,NM_178432 CDK20,CDK20,CDK20,CDK20,CDK20 EXON Silent,Silent,Silent,Silent,Silent rs3750492 9 90582224 [A/G] NM_001170640,NM_001170639,NM_012119,NM_001039803,NM_178432 CDK20,CDK20,CDK20,CDK20,CDK20 EXON Silent,Silent,Silent,Silent,Silent rs560019 9 90583521 [T/C] NM_001170640,NM_001170639,NM_012119,NM_001039803,NM_178432 CDK20,CDK20,CDK20,CDK20,CDK20 Silent,Silent,Silent,Silent,Silent rs28364963 9 90584110 [T/C] NM_001170640,NM_001170639,NM_012119,NM_001039803,NM_178432 CDK20,CDK20,CDK20,CDK20,CDK20 EXON Missense_R219G,Missense_K260R,Missense_K260R,Missense_K281R,Missense_K273R rs2271992 9 90584478 [T/C] NM_001170640,NM_001170639,NM_012119,NM_001039803,NM_178432 CDK20,CDK20,CDK20,CDK20,CDK20 Silent,Silent,Silent,Silent,Silent rs622418 9 90586043 [A/G] NM_001170640,NM_001170639,NM_012119,NM_001039803,NM_178432 CDK20,CDK20,CDK20,CDK20,CDK20 Silent,Silent,Silent,Silent,Silent rs9410653 9 90586221 [A/G] NM_001170640,NM_001170639,NM_012119,NM_001039803,NM_178432 CDK20,CDK20,CDK20,CDK20,CDK20 EXON Synonymous_H73H,Synonymous_H73H,Synonymous_H73H,Synonymous_H73H,Synonymous_H86H rs665983 9 90588903 [T/C] NM_001170640,NM_001170639,NM_012119,NM_001039803,NM_178432 CDK20,CDK20,CDK20,CDK20,CDK20 EXON Synonymous_E41E,Synonymous_E41E,Synonymous_E41E,Synonymous_E41E,Synonymous_E54E rs572992 9 90590650 [A/C] rs3898637 9 90601003 [A/G] rs473082 9 90603115 [A/C] rs10868677 9 90611872 [T/C] rs652529 9 90613915 [A/G] rs7043672 9 90621460 [A/G] rs13296013 9 90627994 [A/G] rs7864469 9 90630239 [T/G] rs10115989 9 90641936 [A/G] rs10780886 9 90645727 [T/C] rs11142050 9 90646449 [A/G] rs7038292 9 90647962 [T/C] rs1331220 9 90648222 [A/G] rs12683872 9 90648841 [A/G] rs10780887 9 90650132 [A/C] rs10125370 9 90650880 [A/G] rs12003735 9 90653725 [A/G] rs11142061 9 90658646 [A/G] rs7871733 9 90664979 [T/C] rs7048705 9 90665712 [T/C] rs11142070 9 90667427 [T/C] rs9969798 9 90668342 [T/C] rs10868691 9 90669303 [T/C] rs2026920 9 90669897 [A/G] rs538970 9 90674178 [A/G] rs10868700 9 90688689 [A/C] NR_135138,NR_135137 LOC102724156,LOC102724156 Silent,Silent rs11142081 9 90689210 [T/G] NR_135138,NR_135137 LOC102724156,LOC102724156 Silent,Silent rs11142085 9 90696337 [A/G] rs2104827 9 90697532 [T/G] rs12001770 9 90697669 [T/C] rs4877394 9 90703042 [T/C] rs7020924 9 90710965 [A/G] rs11142112 9 90720715 [A/C] rs12237927 9 90721446 [A/G] rs11142115 9 90722248 [A/G] rs12342357 9 90759374 [T/C] rs4877406 9 90760805 [T/C] rs10512193 9 90762031 [T/C] rs2150921 9 90763539 [T/C] rs11142135 9 90765354 [T/C] rs10868717 9 90766450 [A/C] rs12551927 9 90772863 [A/G] rs1888875 9 90776494 [T/G] rs13294398 9 90777213 [A/G] rs11142139 9 90777797 [T/C] rs7865830 9 90780166 [A/G] rs7863242 9 90780784 [T/C] rs12685151 9 90789245 [A/G] rs2814851 9 90792721 [A/G] rs2778019 9 90792863 [T/C] rs2814848 9 90796268 [A/G] rs11142151 9 90796678 [A/G] rs2578245 9 90799534 [A/C] rs7034024 9 90801739 [A/C] rs17080774 9 90802614 [T/G] rs7865433 9 90802721 [A/C] rs17053864 9 90803472 [A/G] rs4877127 9 90808582 [T/G] rs2814828 9 90811182 [T/C] rs7045211 9 90816711 [A/G] rs2814837 9 90817188 [A/G] rs2814839 9 90819763 [T/C] rs2492849 9 90820013 [A/C] rs2482488 9 90821421 [A/G] rs2578240 9 90826765 [A/G] rs17053965 9 90831332 [T/C] rs2814845 9 90832856 [T/C] rs2578247 9 90834581 [T/C] rs2578246 9 90835589 [A/G] rs17053978 9 90839031 [A/G] rs10780905 9 90841066 [A/G] rs10780907 9 90842594 [A/C] rs1550286 9 90847356 [T/C] rs17053983 9 90848786 [A/G] rs747021 9 90850936 [T/C] rs17053995 9 90851591 [A/G] rs17054006 9 90852161 [A/G] rs7028051 9 90857957 [T/C] rs17054025 9 90865387 [A/G] rs1438467 9 90865441 [A/G] rs11142202 9 90866595 [A/G] rs10780914 9 90867612 [A/G] rs6560070 9 90868617 [A/G] rs2099632 9 90869047 [A/G] rs893494 9 90875879 [A/G] rs3937594 9 90882154 [T/C] rs10746839 9 90883630 [A/G] rs4877434 9 90891114 [T/G] rs4877435 9 90891529 [T/C] rs10780919 9 90893431 [A/G] rs4877132 9 90895184 [A/G] rs7851719 9 90896018 [A/G] rs10868746 9 90896077 [A/G] rs7867717 9 90899627 [A/G] rs4515651 9 90905263 [T/C] rs7870611 9 90905665 [T/C] rs6560071 9 90908761 [A/C] rs7868935 9 90917641 [T/C] rs12377675 9 90925255 [A/G] rs11142238 9 90925394 [A/C] rs11142239 9 90927030 [T/G] rs10868754 9 90927206 [A/G] rs12340650 9 90931980 [T/C] rs7043994 9 90936207 [A/G] rs12005022 9 90939033 [A/G] rs10125017 9 90945833 [T/C] rs7046181 9 90948749 [T/C] rs12348836 9 90955547 [A/C] rs10121008 9 90966143 [T/C] rs7848669 9 90977673 [A/G] rs3750493 9 91002287 [A/G] rs7870182 9 91006481 [A/G] NM_006717 SPIN1 Silent rs11142277 9 91008303 [A/G] NM_006717 SPIN1 Silent rs10123897 9 91024421 [T/G] NM_006717 SPIN1 Silent rs1183948 9 91025781 [A/C] NM_006717 SPIN1 Silent rs1056657 9 91028857 [T/C] NM_006717 SPIN1 Silent rs12344848 9 91051184 [T/C] NM_006717 SPIN1 Silent rs3010859 9 91099778 [A/G] rs12337803 9 91104414 [A/G] rs11142322 9 91109302 [T/G] rs11142324 9 91109498 [A/G] rs17054177 9 91121886 [T/C] rs13301050 9 91150775 [A/G] NM_145283,NM_001161625 NXNL2,NXNL2 Silent,Silent rs12685193 9 91152492 [T/G] NM_145283,NM_001161625 NXNL2,NXNL2 Silent,Silent rs10868791 9 91154126 [A/G] NM_145283,NM_001161625 NXNL2,NXNL2 Silent,Silent rs7860074 9 91161674 [T/C] NM_145283 NXNL2 Silent rs13292086 9 91175742 [T/C] NM_145283 NXNL2 Silent rs11142341 9 91175857 [T/C] NM_145283 NXNL2 Silent rs7049021 9 91178068 [T/G] NM_145283 NXNL2 Silent rs12346988 9 91183368 [T/C] NM_145283 NXNL2 Silent rs6560097 9 91186956 [T/C] NM_145283 NXNL2 Silent rs4263860 9 91189922 [A/C] NM_145283 NXNL2 Silent rs4269628 9 91190077 [T/C] NM_145283 NXNL2 EXON Silent rs4877453 9 91197917 [A/G] rs7864277 9 91200144 [A/C] rs4877455 9 91200373 [A/G] rs4877136 9 91203868 [A/G] rs6560099 9 91210293 [T/C] rs4877459 9 91211783 [A/C] rs4242609 9 91219303 [A/G] rs4877464 9 91229667 [T/C] rs10512195 9 91254321 [A/G] rs17054259 9 91255143 [A/G] rs4075961 9 91256579 [T/C] rs4626701 9 91259439 [T/C] rs17054265 9 91260562 [T/C] rs7869919 9 91260612 [T/G] rs7048023 9 91262215 [T/C] rs4543636 9 91262296 [A/G] rs7855348 9 91268541 [T/C] rs4308832 9 91271165 [T/C] rs28429278 9 91272494 [A/G] rs9777071 9 91281294 [A/G] rs11516165 9 91290319 [T/C] rs7044739 9 91293114 [T/C] rs7872811 9 91293885 [T/C] rs9410306 9 91295698 [T/C] rs9410313 9 91296517 [T/C] rs17054328 9 91311747 [T/C] rs4559317 9 91313899 [A/G] rs4495506 9 91317827 [T/G] rs9410282 9 91318984 [T/C] rs17080818 9 91328607 [A/C] rs4877047 9 91330562 [A/G] rs9410457 9 91334787 [A/G] rs7042278 9 91337035 [T/C] rs4877059 9 91344293 [T/G] rs4295735 9 91344487 [A/C] rs4609263 9 91344655 [A/C] rs4877066 9 91348970 [T/C] rs1857490 9 91359502 [A/G] rs7869563 9 91362843 [T/C] rs4247466 9 91365367 [T/C] rs1857496 9 91368043 [A/G] rs4877092 9 91369668 [T/G] rs17054421 9 91370155 [T/C] rs17054423 9 91371086 [T/C] rs7848002 9 91377556 [A/G] rs7867153 9 91377672 [A/G] rs7863022 9 91383554 [T/C] rs4877107 9 91383601 [T/C] rs7048152 9 91386221 [T/C] rs7851181 9 91392349 [A/G] rs7038959 9 91397359 [T/C] rs9410340 9 91399821 [A/C] rs9410344 9 91401893 [T/C] rs7867530 9 91415414 [A/C] rs1288652 9 91416645 [A/G] rs2818251 9 91423470 [A/G] rs2653814 9 91423611 [T/G] rs7036143 9 91425294 [A/G] rs9410214 9 91434617 [T/G] rs879850 9 91438244 [T/C] rs9410375 9 91444623 [T/C] rs1779307 9 91449366 [A/C] rs2818249 9 91456777 [A/G] rs10780205 9 91457113 [T/C] rs2174057 9 91460248 [T/C] rs11137433 9 91485533 [T/G] rs7863591 9 91485589 [A/C] rs868073 9 91486658 [T/C] rs10867126 9 91487768 [A/G] rs987824 9 91488725 [T/C] rs6559300 9 91489053 [T/C] rs905363 9 91494640 [A/C] rs1393570 9 91502970 [A/G] rs11137438 9 91503849 [A/G] rs11137439 9 91505370 [T/C] rs905359 9 91506609 [T/G] rs10867131 9 91511000 [T/C] rs4128575 9 91528751 [T/C] rs1156619 9 91530173 [A/C] rs6559311 9 91535231 [A/C] rs10511956 9 91535461 [A/G] rs17054591 9 91535469 [A/G] rs1502693 9 91538158 [A/G] rs7036574 9 91539876 [T/C] rs1875620 9 91540059 [A/G] rs7019570 9 91541169 [A/G] rs9410425 9 91562311 [A/G] rs11137465 9 91562375 [A/G] rs9410427 9 91562866 [A/G] rs9410429 9 91563034 [T/C] rs6559318 9 91569331 [T/G] rs11137468 9 91570795 [T/C] rs12338537 9 91575235 [A/G] rs4294262 9 91575778 [A/C] rs7854677 9 91578102 [A/C] rs6559328 9 91581627 [A/C] rs4570242 9 91587228 [A/G] rs7869712 9 91591582 [A/G] rs11137472 9 91591680 [A/G] rs11137475 9 91594443 [T/G] rs4075163 9 91599103 [A/C] rs11791652 9 91602796 [T/C] rs7022664 9 91604994 [A/G] rs6559331 9 91607869 [T/C] NM_001001938,NM_001142413,NM_005226 C9orf47,C9orf47,S1PR3 EXON Silent,Silent,Silent rs10867149 9 91608628 [T/C] NM_001001938,NM_001142413,NM_005226 C9orf47,C9orf47,S1PR3 EXON Silent,Silent,Silent rs3934594 9 91610543 [A/G] NM_001001938,NM_001142413,NM_005226 C9orf47,C9orf47,S1PR3 EXON Silent,Silent,Silent rs11137481 9 91610595 [T/G] NM_001001938,NM_001142413,NM_005226 C9orf47,C9orf47,S1PR3 EXON Silent,Silent,Silent rs7045576 9 91610929 [A/G] NM_001001938,NM_001142413,NM_005226 C9orf47,C9orf47,S1PR3 EXON Silent,Silent,Silent rs7038457 9 91613066 [T/C] NM_005226 S1PR3 Silent rs7853537 9 91618102 [A/G] NM_005226 S1PR3 EXON Silent rs9314668 9 91620124 [A/G] rs7865979 9 91621197 [A/G] NM_016848 SHC3 EXON Silent rs3750396 9 91622177 [A/G] NM_016848 SHC3 EXON Silent rs9410438 9 91622691 [A/G] NM_016848 SHC3 EXON Silent rs2150611 9 91623709 [A/G] NM_016848 SHC3 EXON Silent rs1125467 9 91623811 [A/G] NM_016848 SHC3 EXON Silent rs944482 9 91625979 [T/C] NM_016848 SHC3 EXON Silent rs10120429 9 91627531 [A/C] NM_016848 SHC3 EXON Silent rs944483 9 91628546 [A/C] NM_016848 SHC3 Silent rs1331180 9 91630548 [T/G] NM_016848 SHC3 Silent rs2316280 9 91635785 [T/C] NM_016848 SHC3 Silent rs10780221 9 91637304 [A/G] NM_016848 SHC3 Silent rs7029876 9 91638212 [A/C] NM_016848 SHC3 Silent rs12115280 9 91641563 [T/C] NM_016848 SHC3 Silent rs9410448 9 91645705 [A/G] NM_016848 SHC3 Silent rs4877041 9 91653749 [A/G] NM_016848 SHC3 Silent rs12337493 9 91654117 [A/G] NM_016848 SHC3 Silent rs3750399 9 91656963 [T/C] NM_016848 SHC3 EXON Synonymous_P446P rs4877042 9 91660158 [T/C] NM_016848 SHC3 Silent rs6559335 9 91662534 [A/G] NM_016848 SHC3 Silent rs11137495 9 91666385 [T/G] NM_016848 SHC3 Silent rs7855350 9 91666487 [A/G] NM_016848 SHC3 Silent rs7021743 9 91666812 [A/C] NM_016848 SHC3 Silent rs2297313 9 91669362 [A/G] NM_016848 SHC3 Silent rs4242599 9 91669947 [A/G] NM_016848 SHC3 Silent rs9410307 9 91672117 [T/C] NM_016848 SHC3 Silent rs11789781 9 91676380 [T/C] NM_016848 SHC3 Silent rs9410453 9 91677941 [T/C] NM_016848 SHC3 Silent rs9410455 9 91680600 [A/G] NM_016848 SHC3 Silent rs17054717 9 91690472 [A/G] NM_016848 SHC3 Silent rs7021961 9 91691091 [T/C] NM_016848 SHC3 Silent rs7037454 9 91710338 [A/C] NM_016848 SHC3 Silent rs1331190 9 91720619 [T/C] NM_016848 SHC3 Silent rs1331189 9 91720645 [T/C] NM_016848 SHC3 Silent rs4876968 9 91726877 [A/G] NM_016848 SHC3 Silent rs2183665 9 91729926 [T/C] NM_016848 SHC3 Silent rs11137521 9 91760103 [A/G] NM_016848 SHC3 Silent rs4534195 9 91768648 [T/C] NM_016848 SHC3 Silent rs4876971 9 91771148 [A/G] NM_016848 SHC3 Silent rs10867158 9 91771642 [A/G] NM_016848 SHC3 Silent rs1411835 9 91775882 [A/G] NM_016848 SHC3 Silent rs13285368 9 91801585 [T/C] rs11137533 9 91805113 [A/G] rs4877062 9 91820998 [A/G] rs17437738 9 91838806 [T/C] rs11137545 9 91841972 [A/G] rs17437920 9 91864233 [A/G] rs4877068 9 91871356 [A/G] rs10441779 9 91878702 [T/C] rs1980888 9 91900556 [A/G] rs1556046 9 91908783 [A/C] rs11137559 9 91920946 [A/G] rs3211650 9 91925227 [T/C] rs3211661 9 91925715 [T/C] rs3211663 9 91926088 [T/C] rs3211667 9 91926700 [A/G] NM_001827 CKS2 Silent rs3211703 9 91932309 [T/C] rs28365780 9 91933352 [T/C] rs3763616 9 91934787 [A/G] NM_001354697,NM_001354698,NM_001282689,NM_001354702,NM_001282688,NM_001354696,NM_024077,NM_001282690 SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12353122 9 91938574 [A/G] NM_001354697,NM_001354698,NM_001282689,NM_001354702,NM_001282688,NM_001354696,NM_024077,NM_001282690 SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7851988 9 91953252 [T/C] NM_001354697,NM_001354698,NM_001282689,NM_001354702,NM_001282688,NM_001354696,NM_024077,NM_001282690 SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7470318 9 91960826 [T/C] NM_001354697,NM_001354698,NM_001282689,NM_001354702,NM_001282688,NM_001354696,NM_024077,NM_001282690 SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11516154 9 91962908 [T/G] NM_001354697,NM_001354698,NM_001282689,NM_001354702,NM_001282688,NM_001354696,NM_024077,NM_001282690 SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs28570640 9 91973613 [T/C] NM_001354697,NM_001354698,NM_001282689,NM_001354702,NM_001282688,NM_001354696,NM_024077,NM_001282690 SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2,SECISBP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7469894 9 91975148 [T/C] rs4876978 9 91976520 [T/C] NM_001142287 SEMA4D EXON Silent rs4876979 9 91978159 [T/C] NM_001142287 SEMA4D Silent rs13283164 9 91979438 [A/G] NM_001142287 SEMA4D Silent rs1134004 9 91981877 [T/C] NM_001142287 SEMA4D Silent rs7856532 9 91984571 [T/G] NM_001142287 SEMA4D Silent rs4877077 9 91989539 [T/C] NM_001142287 SEMA4D Silent rs34731447 9 91990950 [A/G] NM_001142287 SEMA4D Silent rs36050908 9 91991069 [T/C] NM_001142287 SEMA4D Silent rs7469438 9 91997938 [T/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs28402866 9 92002060 [T/C] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs6559349 9 92007225 [T/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs6559350 9 92010796 [T/C] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs7045789 9 92016916 [A/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs9410475 9 92021256 [A/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs9410321 9 92030186 [T/C] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs4074459 9 92034938 [T/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs4132699 9 92036427 [A/C] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs11265876 9 92039416 [T/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs10512197 9 92040475 [T/C] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs10797126 9 92043184 [A/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs4078338 9 92047433 [T/C] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs4602991 9 92047502 [T/C] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs4073713 9 92052258 [A/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs7041468 9 92053124 [A/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs9330435 9 92062038 [A/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs4075521 9 92064548 [T/C] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs7871577 9 92067803 [A/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs9410486 9 92069671 [A/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs11999884 9 92070391 [A/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs4360376 9 92074429 [A/C] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs4560885 9 92076340 [T/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs11265908 9 92077132 [T/C] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs17054916 9 92081623 [A/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs7859211 9 92093576 [A/G] NM_001142287,NM_006378 SEMA4D,SEMA4D Silent,Silent rs4405007 9 92100804 [T/C] rs9695510 9 92105483 [T/C] rs13298567 9 92111105 [A/G] rs10908892 9 92111838 [T/G] rs11265780 9 92116564 [T/C] rs10908893 9 92117102 [T/C] rs1571534 9 92117752 [A/G] rs11265783 9 92121724 [T/C] rs2988071 9 92125867 [A/G] rs17531113 9 92127779 [A/G] rs2149879 9 92128645 [A/G] rs12349546 9 92129573 [A/G] rs17054953 9 92141629 [T/C] rs13290596 9 92143868 [T/C] rs3002331 9 92148993 [A/G] rs1983976 9 92154969 [T/C] rs12000581 9 92156146 [T/G] rs9695328 9 92157176 [T/C] rs2480490 9 92158225 [T/C] rs913807 9 92158829 [A/C] rs12345210 9 92167606 [T/C] rs10908894 9 92170123 [A/G] rs6559362 9 92173910 [A/C] rs7042552 9 92186458 [T/C] rs12336313 9 92191274 [T/C] rs10797116 9 92191467 [T/C] rs11265820 9 92193006 [T/C] rs12343854 9 92196438 [A/C] rs10908898 9 92196724 [T/G] rs2031970 9 92204172 [T/C] rs7871395 9 92209587 [T/C] rs1475537 9 92212750 [T/C] rs1055595 9 92213923 [T/G] rs1007966 9 92213967 [A/G] rs1571536 9 92215638 [T/C] rs3138489 9 92218862 [A/C] rs3138505 9 92220760 [A/G] NM_006705 GADD45G EXON Missense_G112S rs3138509 9 92221637 [A/G] rs3138513 9 92222495 [T/C] rs10908903 9 92228559 [T/G] rs870926 9 92231020 [A/G] rs10908904 9 92231894 [A/C] rs7851960 9 92234041 [T/C] rs7872758 9 92235788 [A/G] rs7850947 9 92237200 [A/G] rs10908905 9 92238244 [T/C] rs7851166 9 92239995 [A/C] rs10124343 9 92248027 [A/C] rs10908907 9 92249584 [A/G] rs4877115 9 92250365 [T/G] rs4876989 9 92254212 [T/C] rs4877116 9 92254248 [A/G] rs7033919 9 92260403 [A/G] NR_024280 UNQ6494 Silent rs1411156 9 92261864 [T/C] NR_024280 UNQ6494 Silent rs6559371 9 92270655 [T/G] NR_024280 UNQ6494 Silent rs10908909 9 92273175 [T/C] NR_024280 UNQ6494 Silent rs7848364 9 92276116 [T/C] NR_024280 UNQ6494 Silent rs2329385 9 92276855 [A/C] NR_024280 UNQ6494 Silent rs1109998 9 92277210 [A/G] NR_024280 UNQ6494 Silent rs4877120 9 92279448 [T/G] NR_024280 UNQ6494 Silent rs11265860 9 92281255 [T/C] NR_024280 UNQ6494 Silent rs4876993 9 92281403 [T/C] NR_024280 UNQ6494 Silent rs10908911 9 92285084 [A/C] NR_024280 UNQ6494 Silent rs4876951 9 92290874 [A/G] NR_024280 UNQ6494 Silent rs10120215 9 92301054 [T/C] NR_024280 UNQ6494 Silent rs4074312 9 92301982 [T/G] NR_024280 UNQ6494 Silent rs11265870 9 92308660 [T/G] NR_024280 UNQ6494 Silent rs7856520 9 92309394 [T/C] NR_024280 UNQ6494 Silent rs10114707 9 92309687 [A/G] NR_024280 UNQ6494 Silent rs4242594 9 92310657 [A/C] NR_024280 UNQ6494 Silent rs4262393 9 92310811 [T/G] NR_024280 UNQ6494 Silent rs10119599 9 92312427 [A/C] NR_024280 UNQ6494 Silent rs12001539 9 92313974 [A/G] NR_024280 UNQ6494 Silent rs11265877 9 92319527 [A/G] NR_024280 UNQ6494 Silent rs10908921 9 92321289 [A/G] NR_024280 UNQ6494 Silent rs7870403 9 92321663 [A/G] NR_024280 UNQ6494 Silent rs6559283 9 92327475 [T/C] NR_024280 UNQ6494 Silent rs11265882 9 92328208 [T/C] NR_024280 UNQ6494 Silent rs11790339 9 92336018 [T/C] rs10118363 9 92339924 [A/C] rs12115250 9 92444702 [A/G] rs10797129 9 92444823 [A/G] rs12376091 9 92448136 [T/C] rs9722251 9 92449055 [A/C] rs9696601 9 92454568 [A/G] rs9722389 9 92456953 [T/C] rs11265920 9 92457327 [T/G] rs10908933 9 92459463 [A/G] rs9330440 9 92464383 [T/C] rs11265930 9 92467404 [A/C] rs9777548 9 92485878 [A/G] rs10797131 9 92486638 [A/G] rs10116554 9 92489679 [A/G] rs10908940 9 92492597 [A/G] rs9330447 9 92494316 [T/C] rs9696730 9 92494807 [T/C] rs10908943 9 92495076 [T/C] rs11265957 9 92498089 [T/C] rs11265961 9 92499064 [A/C] rs12003053 9 92499739 [T/G] rs11265963 9 92499771 [T/C] rs9775766 9 92500586 [T/C] rs9330449 9 92501369 [T/C] rs9775506 9 92501780 [T/C] rs9330451 9 92503272 [T/C] rs12342215 9 92509057 [T/C] rs9777581 9 92510619 [A/G] rs9330454 9 92515514 [A/G] rs10122995 9 92524438 [T/C] rs10114488 9 92526756 [T/C] rs34688910 9 92528104 [T/C] rs28375233 9 92679169 [T/C] rs16905869 9 92679450 [A/G] rs7029990 9 92681245 [A/C] rs16905894 9 92684163 [T/G] rs7021867 9 92685454 [A/C] rs4744475 9 92686142 [A/G] rs10991825 9 92691598 [T/C] rs10820846 9 92693362 [A/G] rs10761114 9 92693434 [T/C] rs10992228 9 92700500 [A/G] rs10992338 9 92704074 [A/G] rs4744157 9 92709313 [T/C] rs2196923 9 92711789 [A/G] rs7045961 9 92713999 [T/G] rs16905942 9 92716596 [A/G] rs7035196 9 92722593 [A/G] rs10993172 9 92723125 [T/C] rs7030989 9 92725441 [T/C] rs10993333 9 92727048 [A/G] rs10993342 9 92727336 [T/G] rs6479587 9 92728873 [A/C] rs10821475 9 92739891 [T/C] NR_109791 LOC101927847 Silent rs2890110 9 92742478 [T/C] NR_109791 LOC101927847 Silent rs1443358 9 92745240 [T/C] NR_109791 LOC101927847 Silent rs12685019 9 92748385 [T/C] NR_109791 LOC101927847 Silent rs12351881 9 92754276 [A/G] rs10821487 9 92755133 [A/C] rs7866392 9 92763235 [A/G] rs1036699 9 92765694 [A/G] rs10993701 9 92769678 [A/C] rs535599 9 92773125 [T/C] rs620311 9 92773905 [A/C] rs652454 9 92776497 [T/C] rs652913 9 92776614 [T/C] rs601472 9 92776695 [T/C] rs535414 9 92789486 [A/G] NR_038882 MIR4290HG Silent rs10820827 9 92792098 [T/C] NR_038882 MIR4290HG Silent rs10991758 9 92793780 [A/G] NR_038882 MIR4290HG Silent rs10991761 9 92794117 [A/G] NR_038882 MIR4290HG Silent rs684476 9 92794619 [T/C] NR_038882 MIR4290HG Silent rs10991799 9 92804166 [T/C] rs10122211 9 92809471 [A/G] rs997758 9 92814420 [A/G] rs997759 9 92814783 [T/G] rs10761113 9 92816727 [A/G] rs599721 9 92817191 [A/G] rs544950 9 92830743 [T/C] rs287860 9 92838827 [A/G] rs1887903 9 92841388 [T/G] rs645706 9 92847174 [T/C] rs11792411 9 92848755 [A/G] rs4744088 9 92850878 [A/G] rs1329045 9 92852199 [A/C] rs7874990 9 92852944 [T/C] rs12115490 9 92853543 [T/C] rs10123553 9 92855420 [T/C] rs10992049 9 92855977 [T/C] rs423239 9 92856946 [T/C] rs10761128 9 92858197 [T/C] rs16906191 9 92859704 [T/C] rs4744096 9 92862486 [T/C] rs10992083 9 92863041 [T/C] rs4743853 9 92867363 [A/G] rs16906203 9 92869370 [T/C] rs1854444 9 92870113 [T/C] rs1329047 9 92870296 [T/C] rs7852983 9 92870425 [T/C] rs7860989 9 92872227 [T/C] rs7851675 9 92872306 [A/C] rs17460947 9 92872751 [T/C] rs4744106 9 92873665 [A/G] rs7042866 9 92875390 [A/C] rs7848094 9 92876060 [T/C] rs4743859 9 92876666 [A/G] rs10992192 9 92887130 [A/G] rs2081670 9 92887231 [T/C] rs964912 9 92891077 [A/G] rs16906228 9 92891674 [A/C] rs17445269 9 92891865 [A/G] rs10992211 9 92892015 [A/G] rs4744117 9 92896723 [A/G] rs7867301 9 92897297 [A/G] rs10481717 9 92897338 [T/C] rs7875016 9 92898149 [T/G] rs12352194 9 92898177 [A/G] rs10992247 9 92900609 [A/G] rs7025302 9 92903522 [A/G] rs10820944 9 92903671 [T/C] rs12337287 9 92906025 [A/C] rs7860895 9 92907061 [T/C] rs10820953 9 92907960 [T/C] rs10820958 9 92909654 [A/G] rs10992278 9 92910367 [A/C] rs7468504 9 92925179 [T/C] rs10992326 9 92927997 [T/C] rs4744131 9 92931861 [T/G] rs1412126 9 92939476 [A/C] rs7048754 9 92941210 [T/C] rs1854923 9 92943286 [A/G] rs10761166 9 92946648 [A/G] rs1539519 9 92950272 [T/C] rs1854924 9 92960794 [A/G] rs12347445 9 92961558 [T/C] rs2114518 9 92962076 [T/C] rs6479430 9 92962977 [T/G] rs10992452 9 92963339 [A/C] rs7023271 9 92967125 [T/C] rs12345191 9 92992878 [A/G] rs7023466 9 93005808 [A/G] rs10821091 9 93008041 [T/C] rs7043530 9 93010541 [T/C] rs7865330 9 93015989 [T/C] rs1777018 9 93025338 [T/C] rs1777019 9 93025656 [T/C] rs2380291 9 93029002 [T/C] rs11792210 9 93029282 [A/G] rs12346947 9 93031263 [T/C] rs1410856 9 93033040 [T/C] rs10992761 9 93036856 [T/C] rs2771091 9 93039369 [T/C] rs2380292 9 93046322 [T/C] rs1777003 9 93049422 [T/C] rs2771095 9 93051826 [A/G] rs2771098 9 93058963 [A/G] rs10217176 9 93065137 [T/G] NR_109795 LINC01508 Silent rs2798018 9 93067019 [T/C] NR_109795 LINC01508 Silent rs2771102 9 93067144 [T/C] NR_109795 LINC01508 Silent rs1754069 9 93067790 [T/C] NR_109795 LINC01508 Silent rs729009 9 93071368 [T/C] NR_109795 LINC01508 Silent rs1318387 9 93071559 [A/G] NR_109795 LINC01508 Silent rs1777011 9 93074228 [A/G] NR_109795 LINC01508 Silent rs2771090 9 93080054 [A/G] NR_109795 LINC01508 Silent rs2246522 9 93080194 [A/G] NR_109795 LINC01508 Silent rs16906332 9 93081851 [A/G] NR_109795 LINC01508 Silent rs16936969 9 93083867 [A/C] NR_109795 LINC01508 Silent rs10993008 9 93085382 [A/G] NR_109795 LINC01508 Silent rs16906336 9 93088115 [T/C] NR_109795 LINC01508 Silent rs6479525 9 93093378 [A/G] NR_109795 LINC01508 Silent rs1777045 9 93095891 [A/C] NR_109795 LINC01508 Silent rs2798032 9 93098295 [A/G] NR_109795 LINC01508 Silent rs1590811 9 93099104 [A/G] NR_109795 LINC01508 Silent rs12348363 9 93100550 [T/C] NR_109795 LINC01508 Silent rs1012161 9 93102793 [A/G] NR_109795 LINC01508 Silent rs979464 9 93103388 [A/G] NR_109795 LINC01508 Silent rs7048728 9 93104329 [T/C] NR_109795 LINC01508 Silent rs1329092 9 93105008 [T/C] NR_109795 LINC01508 Silent rs979814 9 93106543 [A/G] NR_109795 LINC01508 Silent rs979816 9 93106801 [T/C] NR_109795 LINC01508 Silent rs874977 9 93111241 [T/C] NR_109795 LINC01508 Silent rs748121 9 93112028 [T/C] NR_109795 LINC01508 Silent rs1623337 9 93129283 [A/G] NR_109795 LINC01508 Silent rs12004191 9 93130383 [T/C] NR_109795 LINC01508 Silent rs1777052 9 93130796 [T/C] NR_109795 LINC01508 Silent rs7020862 9 93140338 [T/C] NR_109795 LINC01508 Silent rs1648477 9 93141541 [T/C] NR_109795 LINC01508 Silent rs1889204 9 93148230 [A/G] NR_109795 LINC01508 Silent rs1426506 9 93148579 [T/C] NR_109795 LINC01508 Silent rs10739979 9 93152933 [A/G] NR_109795 LINC01508 Silent rs2004205 9 93154530 [T/C] NR_109795 LINC01508 Silent rs4534243 9 93157619 [A/C] NR_109795 LINC01508 Silent rs10993323 9 93158434 [A/G] NR_109795 LINC01508 Silent rs1576290 9 93162602 [A/G] NR_109795 LINC01508 Silent rs2162333 9 93163805 [A/G] NR_109795 LINC01508 Silent rs10993355 9 93168446 [T/C] NR_109795 LINC01508 Silent rs10821400 9 93169441 [A/G] NR_109795 LINC01508 Silent rs4744418 9 93183404 [T/C] NR_109795 LINC01508 Silent rs10993452 9 93187329 [T/C] NR_109795 LINC01508 Silent rs10821428 9 93187808 [T/C] NR_109795 LINC01508 Silent rs10821444 9 93192521 [A/G] NR_109795 LINC01508 Silent rs6479594 9 93193062 [T/C] NR_109795 LINC01508 Silent rs10821452 9 93199571 [A/G] rs10117791 9 93200337 [A/G] rs17450197 9 93205277 [A/G] rs7858582 9 93214896 [T/C] rs4743992 9 93219568 [T/C] rs10761383 9 93222465 [T/G] rs1549508 9 93225765 [T/C] NR_034157 LINC01501 EXON Silent rs10821466 9 93227637 [T/G] NR_034157 LINC01501 Silent rs16906607 9 93229317 [A/G] NR_034157 LINC01501 Silent rs1426507 9 93231161 [A/G] NR_034157 LINC01501 Silent rs1365369 9 93236549 [T/G] NR_034157 LINC01501 Silent rs1863559 9 93240193 [A/G] NR_034157 LINC01501 Silent rs10761389 9 93246553 [A/G] NR_034157 LINC01501 Silent rs12339486 9 93248431 [A/G] NR_034157 LINC01501 Silent rs4743995 9 93252163 [A/G] NR_034157 LINC01501 Silent rs7862334 9 93256092 [T/C] NR_034157 LINC01501 Silent rs16906632 9 93260040 [A/G] NR_034157 LINC01501 Silent rs12353086 9 93265378 [A/C] NR_034157 LINC01501 Silent rs1346211 9 93266508 [T/C] NR_034157 LINC01501 Silent rs10993564 9 93272277 [T/C] NR_034157 LINC01501 Silent rs4744469 9 93284804 [A/G] NR_034157 LINC01501 Silent rs10993570 9 93285878 [T/C] NR_034157 LINC01501 Silent rs7341780 9 93289273 [A/C] NR_034157 LINC01501 Silent rs7870746 9 93289728 [A/G] NR_034157 LINC01501 Silent rs12685637 9 93297966 [T/C] NR_034157 LINC01501 Silent rs690211 9 93309082 [A/C] NR_034157 LINC01501 Silent rs12002017 9 93316821 [A/C] NR_034157 LINC01501 Silent rs10993593 9 93331003 [T/C] NR_034157 LINC01501 Silent rs4743997 9 93332475 [A/C] NR_034157 LINC01501 Silent rs690140 9 93333075 [T/C] NR_034157 LINC01501 Silent rs1331497 9 93343832 [A/C] NR_034157 LINC01501 Silent rs690552 9 93344344 [A/C] NR_034157 LINC01501 Silent rs16906689 9 93348404 [A/G] rs2613339 9 93348786 [A/G] rs525843 9 93350920 [T/C] rs555362 9 93351868 [T/C] rs690567 9 93353987 [T/G] rs7856157 9 93357338 [T/C] rs689917 9 93359512 [A/G] rs690150 9 93359638 [A/G] rs563242 9 93362120 [T/C] rs12004340 9 93366369 [A/G] rs7868194 9 93369784 [A/G] rs1542479 9 93373049 [A/G] NM_017594 DIRAS2 EXON Silent rs3827821 9 93374507 [A/G] NM_017594 DIRAS2 EXON Silent rs2231776 9 93375696 [A/G] NM_017594 DIRAS2 EXON Synonymous_A138A rs690111 9 93377290 [T/G] NM_017594 DIRAS2 Silent rs1017753 9 93377901 [T/C] NM_017594 DIRAS2 Silent rs16906717 9 93379328 [A/G] NM_017594 DIRAS2 Silent rs690232 9 93382438 [A/G] NM_017594 DIRAS2 Silent rs563726 9 93387516 [T/C] NM_017594 DIRAS2 Silent rs1331501 9 93392332 [T/C] NM_017594 DIRAS2 Silent rs16906722 9 93396081 [T/C] NM_017594 DIRAS2 Silent rs16906728 9 93397205 [A/G] NM_017594 DIRAS2 Silent rs4744473 9 93402190 [T/G] NM_017594 DIRAS2 Silent rs1412005 9 93409161 [T/G] rs689687 9 93410201 [T/C] rs1331507 9 93412927 [A/G] rs10993618 9 93413258 [A/G] rs4744000 9 93418243 [T/C] rs2892176 9 93428196 [A/G] rs753593 9 93434093 [T/C] rs1173099 9 93441674 [A/C] rs1173100 9 93443531 [A/G] rs1173102 9 93445063 [T/C] rs10993628 9 93445145 [A/G] rs1173104 9 93445335 [T/G] rs16906767 9 93455943 [T/C] rs4744486 9 93459305 [T/C] rs1173107 9 93461649 [A/G] rs10993639 9 93466631 [A/G] rs1172896 9 93469911 [T/G] rs4744489 9 93471627 [A/G] rs7033823 9 93474143 [T/G] rs2613319 9 93476005 [A/C] rs12336030 9 93482553 [A/C] rs2810919 9 93486569 [T/C] rs34993748 9 93514742 [T/C] rs1148851 9 93526206 [A/G] rs914926 9 93526329 [A/C] rs10821495 9 93530889 [T/G] rs1148853 9 93530909 [A/G] rs290265 9 93538038 [A/G] rs291007 9 93539879 [A/G] rs290275 9 93546691 [A/G] rs4744498 9 93547691 [A/G] rs10993688 9 93550754 [A/G] rs290267 9 93552550 [T/C] rs10993693 9 93557698 [A/G] rs2774237 9 93558346 [T/G] rs290991 9 93561450 [T/G] rs10821507 9 93561614 [T/G] rs290986 9 93563536 [A/G] rs1333633 9 93567572 [A/G] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs7868795 9 93570012 [A/G] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs7036417 9 93570505 [T/C] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs3789889 9 93571341 [A/G] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs7020331 9 93572543 [A/G] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs290240 9 93573542 [A/G] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs12550873 9 93573597 [T/C] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs290237 9 93574650 [T/C] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs10993697 9 93575966 [T/C] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs10993698 9 93577781 [T/G] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs4744505 9 93579997 [A/G] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs1333630 9 93581182 [T/C] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs914925 9 93584793 [A/G] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs1081767 9 93586759 [T/C] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs187306 9 93587089 [T/C] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs12337607 9 93589112 [A/G] NM_001135052,NM_003177,NM_001174168 SYK,SYK,SYK Silent,Silent,Silent rs290974 9 93590403 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs290213 9 93595807 [T/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs290212 9 93596067 [T/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs1025325 9 93597669 [T/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs10993705 9 93598856 [T/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs4744512 9 93599890 [T/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs1864202 9 93601955 [T/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs17489214 9 93603138 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs10993707 9 93605269 [T/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs10993708 9 93606091 [A/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs7855964 9 93606103 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs2278278 9 93608739 [A/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs2035073 9 93609419 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs4744514 9 93610761 [T/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs10993713 9 93612959 [T/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs7032304 9 93615496 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs7863711 9 93616303 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs16905730 9 93617445 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs10993725 9 93618236 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs10124093 9 93619736 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs12001366 9 93622150 [A/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs1760125 9 93622835 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs10993728 9 93623238 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs10821515 9 93624896 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs4529574 9 93626241 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs4744516 9 93627484 [T/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs2991216 9 93628027 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs7864625 9 93633948 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs290229 9 93634413 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs10512202 9 93635975 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs290227 9 93636664 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs2290890 9 93637015 [T/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK EXON Synonymous_P332P,Synonymous_P355P,Synonymous_P332P,Synonymous_P355P rs2290887 9 93640009 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK EXON Synonymous_L423L,Synonymous_L446L,Synonymous_L423L,Synonymous_L446L rs2306041 9 93641175 [T/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK EXON Synonymous_Y484Y,Synonymous_Y507Y,Synonymous_Y484Y,Synonymous_Y507Y rs2306040 9 93641199 [T/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK EXON Synonymous_L492L,Synonymous_L515L,Synonymous_L492L,Synonymous_L515L rs10761395 9 93642897 [T/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs1755938 9 93644948 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs290256 9 93651615 [T/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs290255 9 93651657 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs10993746 9 93653237 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs2613320 9 93654090 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs1172665 9 93654504 [A/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs1172663 9 93654697 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs726757 9 93655385 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK Silent,Silent,Silent,Silent rs1049164 9 93658206 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK EXON Silent,Silent,Silent,Silent rs158688 9 93658854 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK EXON Silent,Silent,Silent,Silent rs12344755 9 93658952 [T/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK EXON Silent,Silent,Silent,Silent rs158687 9 93658978 [A/G] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK EXON Silent,Silent,Silent,Silent rs10512203 9 93659034 [A/C] NM_001135052,NM_003177,NM_001174168,NM_001174167 SYK,SYK,SYK,SYK EXON Silent,Silent,Silent,Silent rs1551747 9 93661352 [T/C] rs1760118 9 93662205 [A/G] rs10993751 9 93662641 [A/G] rs10993752 9 93662762 [T/C] rs4744520 9 93663201 [A/G] rs7864740 9 93663561 [T/C] rs10993755 9 93665389 [A/G] rs2774241 9 93665453 [A/C] rs291765 9 93667010 [T/C] rs1585461 9 93667457 [T/C] rs10125876 9 93667894 [T/C] rs291768 9 93668008 [T/G] rs10993760 9 93668751 [A/G] rs10993761 9 93668891 [A/G] rs1675315 9 93671163 [A/G] rs7035017 9 93677731 [T/C] rs7865699 9 93678172 [T/C] rs291753 9 93681295 [A/G] rs10991692 9 93685457 [T/C] rs1460829 9 93688438 [A/G] rs10991696 9 93689819 [T/C] rs169744 9 93692552 [A/G] rs10123208 9 93692988 [T/G] rs10117309 9 93693246 [T/C] rs192650 9 93695725 [A/G] rs1675305 9 93697190 [A/G] rs1675306 9 93697223 [A/C] rs291748 9 93701052 [A/G] rs10991704 9 93704904 [T/G] rs10991705 9 93704926 [A/G] rs296663 9 93710061 [A/G] rs296655 9 93711881 [T/C] rs12341958 9 93712104 [A/G] rs17569206 9 93712701 [T/C] rs296650 9 93714080 [T/C] rs177040 9 93714388 [T/C] rs10991719 9 93716229 [A/G] rs10991722 9 93718266 [A/G] rs10739911 9 93719846 [T/G] rs426365 9 93723833 [T/C] rs382847 9 93724431 [T/C] rs368754 9 93724516 [A/C] rs7032584 9 93724845 [T/C] rs169851 9 93727745 [A/G] rs296690 9 93728360 [A/G] rs749101 9 93729125 [T/C] rs192703 9 93730292 [T/C] rs12352804 9 93731058 [A/G] rs10820820 9 93731198 [T/C] rs7865547 9 93736643 [T/G] rs296711 9 93739202 [T/C] rs296713 9 93740708 [T/C] rs9696872 9 93741233 [T/C] rs296724 9 93745381 [T/C] rs7047670 9 93752522 [A/G] rs296610 9 93763731 [T/G] rs296646 9 93774385 [T/C] rs7852422 9 93775677 [T/C] rs296630 9 93787482 [T/C] rs10121342 9 93791410 [A/G] rs12685800 9 93793696 [A/G] rs1551746 9 93800017 [T/G] rs10761105 9 93804208 [T/C] rs7027785 9 93824836 [A/G] rs7025659 9 93828321 [A/C] NR_033912 LOC100129316 EXON Silent rs296648 9 93829019 [A/G] NR_033912 LOC100129316 EXON Silent rs10820828 9 93834060 [T/C] NR_033912 LOC100129316 Silent rs296614 9 93837417 [A/G] rs3853607 9 93837497 [T/C] rs296639 9 93840659 [T/C] rs7859968 9 93840753 [A/C] rs296638 9 93842021 [A/C] rs296636 9 93843942 [T/C] rs296634 9 93844314 [A/G] rs395612 9 93849856 [T/C] rs393369 9 93851440 [T/C] rs430794 9 93852815 [T/G] rs582337 9 93853457 [A/G] rs365426 9 93858333 [T/C] rs296620 9 93861920 [T/C] rs296618 9 93862080 [A/G] rs773280 9 93867445 [A/C] rs773283 9 93874879 [A/G] rs2296751 9 93881354 [T/G] NR_135306 LINC00484 EXON Silent rs2274464 9 93887045 [A/G] NR_135306 LINC00484 Silent rs7036424 9 93893941 [A/G] NR_135306 LINC00484 Silent rs10820830 9 93899625 [A/C] NR_135306 LINC00484 Silent rs7033430 9 93901159 [T/G] NR_135306 LINC00484 Silent rs7034207 9 93901785 [T/G] NR_135306 LINC00484 Silent rs4604577 9 93904257 [A/G] NR_135306 LINC00484 Silent rs10991781 9 93909589 [A/G] NR_135306 LINC00484 Silent rs943502 9 93920745 [A/G] NR_135306 LINC00484 Silent rs16907199 9 93923617 [T/C] NR_135306 LINC00484 Silent rs12351170 9 93925207 [A/G] NR_135306 LINC00484 Silent rs1887369 9 93926928 [T/C] NR_135306 LINC00484 Silent rs16907201 9 93927913 [A/G] NR_135306 LINC00484 Silent rs10991797 9 93930671 [A/G] NR_135306 LINC00484 Silent rs10820838 9 93930913 [A/G] NR_135306 LINC00484 Silent rs4744038 9 93934851 [A/G] NR_135306 LINC00484 Silent rs773519 9 93944244 [T/C] NR_135306 LINC00484 Silent rs10991808 9 93946379 [T/C] rs10991816 9 93950513 [A/G] rs10991818 9 93951043 [T/C] rs10991820 9 93952940 [T/C] rs10512206 9 93961118 [A/G] rs7025775 9 93963953 [A/G] rs7025567 9 93969769 [A/G] rs12236197 9 93971858 [A/G] rs16907277 9 93972658 [A/G] rs773507 9 93974553 [T/G] rs773506 9 93975471 [A/G] rs9785225 9 93982492 [A/G] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs773515 9 93982932 [T/C] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs773518 9 93997764 [T/G] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs7857616 9 94004897 [T/C] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs16907311 9 94019410 [T/G] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs10991853 9 94023575 [A/G] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs7043552 9 94025991 [A/G] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs1615811 9 94029256 [A/G] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs12238387 9 94034568 [A/G] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs2482340 9 94037842 [A/G] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs2482338 9 94037873 [T/C] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs10512209 9 94047814 [T/C] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs10991869 9 94049879 [T/C] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs298728 9 94062978 [T/C] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs10991880 9 94076827 [A/C] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs7874056 9 94087622 [T/G] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH EXON Synonymous_I161I,Silent,Synonymous_I52I,Synonymous_I52I,Synonymous_I52I rs7870604 9 94096215 [T/C] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs7868771 9 94108757 [A/G] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs12552364 9 94120749 [T/C] NM_001698,NM_001306190,NM_001351431,NM_001351432,NM_001351433 AUH,AUH,AUH,AUH,AUH Silent,Silent,Silent,Silent,Silent rs774224 9 94141918 [A/C] rs10991917 9 94153503 [T/C] rs16907447 9 94154803 [T/C] rs10991921 9 94157846 [A/G] rs894962 9 94161700 [T/C] rs883121 9 94162081 [A/G] rs7024443 9 94164373 [A/C] rs1758695 9 94165889 [T/G] rs1619450 9 94169155 [A/G] rs28569137 9 94170311 [T/C] rs3747840 9 94171628 [T/C] NM_005384,NM_001290000,NM_001289999 NFIL3,NFIL3,NFIL3 EXON Synonymous_X463X,Synonymous_X463X,Synonymous_X463X rs7021746 9 94176261 [A/G] NM_005384,NM_001290000,NM_001289999 NFIL3,NFIL3,NFIL3 Silent,Silent,Silent rs2482357 9 94179978 [A/G] NM_005384,NM_001290000,NM_001289999 NFIL3,NFIL3,NFIL3 Silent,Silent,Silent rs2440592 9 94181951 [A/G] NM_005384,NM_001290000,NM_001289999 NFIL3,NFIL3,NFIL3 Silent,Silent,Silent rs2482704 9 94182363 [T/G] NM_005384,NM_001290000,NM_001289999 NFIL3,NFIL3,NFIL3 Silent,Silent,Silent rs13297268 9 94188141 [A/G] rs10820853 9 94190241 [A/G] rs7032571 9 94190673 [A/G] rs1467780 9 94192804 [T/C] rs774227 9 94193941 [A/G] rs809568 9 94199485 [A/G] rs2482709 9 94199559 [T/C] rs11535536 9 94202927 [A/G] rs1412470 9 94214002 [T/C] rs1981030 9 94217301 [T/C] rs7867022 9 94221535 [T/C] rs10820857 9 94222921 [A/G] rs12345170 9 94229429 [T/G] rs6479339 9 94236664 [T/C] rs12685188 9 94240052 [A/C] rs10991949 9 94245194 [A/G] rs16907524 9 94245669 [A/G] rs4743836 9 94246676 [T/C] rs4744055 9 94249082 [T/C] rs1571892 9 94258836 [A/C] rs7032300 9 94259474 [C/G] rs7035655 9 94260376 [A/G] rs6479342 9 94261753 [A/C] rs12350612 9 94264346 [A/G] rs12350727 9 94264616 [A/G] rs768056 9 94266286 [T/C] rs16907551 9 94267243 [T/C] rs7868550 9 94269967 [A/G] rs7025323 9 94270414 [T/G] rs7038274 9 94273334 [A/G] rs10820865 9 94279402 [T/C] rs7856591 9 94281499 [T/G] rs10820870 9 94291378 [T/C] rs12344821 9 94299460 [T/G] rs10481715 9 94310766 [A/G] rs9409602 9 94312726 [T/C] rs10991978 9 94313839 [A/C] rs6479358 9 94314110 [T/C] rs1546101 9 94320054 [A/G] rs10991990 9 94331204 [T/C] rs10991991 9 94331504 [T/C] rs1388966 9 94333426 [A/G] rs902923 9 94333599 [T/C] rs902921 9 94333889 [T/C] rs9409609 9 94339510 [A/G] rs9409610 9 94341698 [A/G] rs4744064 9 94342486 [T/C] rs10991994 9 94342986 [T/C] rs10991995 9 94343125 [T/C] rs7033293 9 94363366 [A/G] rs1027269 9 94368561 [T/C] rs4744070 9 94369120 [T/G] rs1319000 9 94370675 [T/C] rs7032779 9 94372455 [A/G] rs7850575 9 94373024 [A/G] rs10512215 9 94374714 [A/G] rs1021439 9 94379035 [A/G] rs1021441 9 94379459 [T/G] rs4744084 9 94387597 [T/G] rs9695578 9 94391746 [A/G] rs12339155 9 94394640 [T/C] rs12340405 9 94395522 [T/C] rs1492682 9 94396059 [A/G] rs7852614 9 94396366 [A/C] rs10992022 9 94396676 [A/G] rs12344333 9 94398543 [T/C] NR_037472 MIR3910-1 EXON Silent rs4744087 9 94398847 [A/G] rs2131304 9 94403445 [A/C] rs10992024 9 94405452 [A/G] rs10992026 9 94405559 [A/G] rs1492685 9 94406084 [T/C] rs9409636 9 94406606 [T/C] rs10992029 9 94408117 [A/C] rs7851193 9 94408473 [A/G] rs9409449 9 94412540 [A/C] rs2076773 9 94414784 [A/G] rs9299395 9 94417069 [T/G] rs7032274 9 94420140 [T/C] rs17506543 9 94422821 [T/G] rs9299396 9 94427820 [T/C] rs10992039 9 94428149 [T/G] rs10046802 9 94437294 [T/C] rs1388967 9 94441201 [T/C] rs10992043 9 94441745 [A/G] rs10820896 9 94444830 [T/C] rs2892376 9 94445809 [A/G] rs2387871 9 94445943 [A/G] rs12115281 9 94448777 [T/C] rs1201041 9 94454217 [A/G] rs10992053 9 94455171 [A/G] rs923769 9 94456714 [T/C] rs12348947 9 94458669 [A/G] rs10820899 9 94482041 [A/G] rs7466603 9 94483198 [T/C] rs10992058 9 94483759 [A/G] rs1135150 9 94485232 [A/G] NM_004560 ROR2 EXON Silent rs10761129 9 94486321 [T/C] NM_004560 ROR2 EXON Missense_V819I rs2230577 9 94486622 [A/G] NM_004560 ROR2 EXON Synonymous_P718P rs10992065 9 94487459 [T/C] NM_004560 ROR2 Silent rs4073735 9 94488415 [T/C] NM_004560 ROR2 Silent rs10992066 9 94489212 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs4237215 9 94497680 [A/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs9409651 9 94498550 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs16907720 9 94499797 [A/G] NM_004560,NM_001318204 ROR2,ROR2 EXON Synonymous_D166D,Synonymous_D166D rs10992075 9 94501891 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs9409653 9 94506153 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs3935601 9 94508700 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs16907725 9 94510145 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10739919 9 94514322 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs4467996 9 94517715 [A/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs3824426 9 94518789 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs17585941 9 94525991 [A/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs4452868 9 94527657 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10992085 9 94528401 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs9409461 9 94530989 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7026175 9 94532382 [A/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10992087 9 94533121 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs3802377 9 94538167 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs4467997 9 94539018 [A/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10992097 9 94542019 [A/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7029673 9 94542162 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs17514461 9 94543673 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs3935382 9 94546564 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs4378021 9 94547058 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs2103301 9 94561730 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7029814 9 94562681 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs16907793 9 94564762 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs12337908 9 94566701 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs16907798 9 94567537 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7867961 9 94570125 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10992120 9 94572614 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10992121 9 94573753 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7041224 9 94577828 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs4743855 9 94581258 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs11790808 9 94588498 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs12551140 9 94589135 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7867707 9 94597646 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs17587223 9 94600207 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs12003273 9 94601233 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs12002478 9 94603970 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs2141368 9 94609451 [A/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10992132 9 94614626 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10992142 9 94625960 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7850118 9 94626543 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs12552858 9 94629592 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10992144 9 94631630 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs11789730 9 94631730 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs11792818 9 94633130 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs12554669 9 94634668 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs1528363 9 94639795 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs1881389 9 94640621 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs4744110 9 94642450 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10761133 9 94646958 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7858435 9 94651415 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10992151 9 94652613 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10512219 9 94656016 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs4430151 9 94662474 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs3905385 9 94668733 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7866188 9 94681588 [A/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10116326 9 94682964 [G/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs16907979 9 94683050 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs2001917 9 94685926 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7045073 9 94686736 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs1892263 9 94687601 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10992161 9 94687927 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7032998 9 94692480 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7034006 9 94696779 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7037255 9 94696954 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7038397 9 94697108 [A/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7038823 9 94697487 [T/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7863425 9 94705717 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs7048699 9 94708403 [A/G] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs9774945 9 94710847 [A/C] NM_004560,NM_001318204 ROR2,ROR2 Silent,Silent rs10820926 9 94713368 [T/C] rs10761137 9 94728959 [T/C] rs10992183 9 94733613 [A/G] rs10992190 9 94758241 [A/G] rs6479395 9 94758498 [T/C] rs7867394 9 94763136 [A/G] rs7045602 9 94764233 [T/C] rs7018784 9 94765564 [T/G] rs6479397 9 94769170 [A/G] rs7039002 9 94775387 [A/G] rs7944 9 94794302 [T/C] NM_006415,NM_001281303 SPTLC1,SPTLC1 EXON Silent,Silent rs12006507 9 94796416 [A/G] NM_006415,NM_001281303 SPTLC1,SPTLC1 Silent,Silent rs10820934 9 94796491 [T/C] NM_006415,NM_001281303 SPTLC1,SPTLC1 Silent,Silent rs3847308 9 94800146 [T/G] NM_006415,NM_001281303 SPTLC1,SPTLC1 Silent,Silent rs7858659 9 94822146 [A/C] NM_006415,NM_001281303 SPTLC1,SPTLC1 Silent,Silent rs10992224 9 94841258 [A/G] NM_006415,NM_001281303 SPTLC1,SPTLC1 Silent,Silent rs16908135 9 94842715 [T/C] NM_006415,NM_001281303,NM_178324 SPTLC1,SPTLC1,SPTLC1 Silent,Silent,Silent rs7029539 9 94864322 [A/G] NM_006415,NM_001281303,NM_178324 SPTLC1,SPTLC1,SPTLC1 Silent,Silent,Silent rs7858974 9 94880110 [A/G] rs7024547 9 94882488 [T/C] rs10992236 9 94883070 [T/C] rs7048339 9 94883880 [A/G] rs12349856 9 94885207 [A/G] rs2274921 9 94907008 [A/G] NR_027341 LINC00475 Silent rs2282199 9 94909375 [A/G] NR_027341 LINC00475 Silent rs7044976 9 94909996 [A/G] NR_027341 LINC00475 Silent rs7874985 9 94919766 [A/G] NR_027341 LINC00475 Silent rs10465156 9 94920495 [A/G] NR_027341 LINC00475 EXON Silent rs1970119 9 94922307 [A/C] rs6479409 9 94927187 [A/G] rs7035248 9 94927564 [A/G] rs7849530 9 94927735 [A/G] rs10992261 9 94935527 [T/C] rs4744122 9 94939615 [T/C] rs4743863 9 94944778 [T/C] rs4743864 9 94947595 [A/G] NM_001350291 PRSS47 EXON Silent rs11793122 9 94949715 [A/G] NM_001350291 PRSS47 Silent rs7023755 9 94949905 [T/G] NM_001350291 PRSS47 Silent rs11790258 9 94951235 [T/C] NM_001350291 PRSS47 Silent rs3858097 9 94951819 [A/G] NM_001350291 PRSS47 Silent rs10123080 9 94962103 [T/C] rs3780346 9 94974188 [A/G] NM_002161,NM_013417,NR_073446 IARS,IARS,IARS Silent,Silent,Silent rs556155 9 94985637 [T/C] NM_002161,NM_013417,NR_073446 IARS,IARS,IARS EXON Missense_K1182E,Missense_K1182E,Silent rs895639 9 95007976 [T/C] NM_002161,NM_013417,NR_073446 IARS,IARS,IARS Silent,Silent,Silent rs16908234 9 95009786 [A/G] NM_002161,NM_013417,NR_073446 IARS,IARS,IARS EXON Synonymous_Y888Y,Synonymous_Y888Y,Silent rs2295940 9 95036903 [T/C] NM_002161,NM_013417,NR_073446 IARS,IARS,IARS Silent,Silent,Silent rs10820964 9 95041636 [A/G] NM_002161,NM_013417,NR_073446 IARS,IARS,IARS Silent,Silent,Silent rs10119535 9 95044229 [A/G] NM_002161,NM_013417,NR_073446 IARS,IARS,IARS Silent,Silent,Silent rs10739927 9 95052081 [T/G] NM_002161,NM_013417,NR_073446 IARS,IARS,IARS Silent,Silent,Silent rs3758230 9 95056446 [T/C] rs710163 9 95059804 [A/G] NM_017948,NM_001256394,NM_001330722,NR_046106 NOL8,NOL8,NOL8,NOL8 EXON Silent,Silent,Silent,Silent rs9409664 9 95070095 [A/G] NM_017948,NM_001256394,NM_001330722,NR_046106 NOL8,NOL8,NOL8,NOL8 Silent,Silent,Silent,Silent rs17518956 9 95070787 [A/G] NM_017948,NM_001256394,NM_001330722,NR_046106 NOL8,NOL8,NOL8,NOL8 Silent,Silent,Silent,Silent rs7872423 9 95083516 [T/C] NM_017948,NM_001256394,NM_001330722,NR_046106 NOL8,NOL8,NOL8,NOL8 Silent,Silent,Silent,Silent rs10123342 9 95087824 [T/G] NM_017948,NM_001256394,NM_001330722,NR_046106,NM_001286969,NM_001012267 NOL8,NOL8,NOL8,NOL8,CENPP,CENPP EXON Silent,Silent,Silent,Silent,Silent,Silent rs10992308 9 95096811 [A/G] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs10992312 9 95105638 [A/G] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs7026361 9 95138564 [T/G] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs1121978 9 95140351 [T/G] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs13283617 9 95144650 [T/G] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs1380 9 95147434 [T/C] NM_001286969,NM_001012267,NM_014057,NM_033014,NM_024416 CENPP,CENPP,OGN,OGN,OGN EXON Silent,Silent,Silent,Silent,Silent rs10992321 9 95156475 [T/G] NM_001286969,NM_001012267,NM_014057,NM_033014,NM_024416 CENPP,CENPP,OGN,OGN,OGN Silent,Silent,Silent,Silent,Silent rs10992322 9 95159196 [A/G] NM_001286969,NM_001012267,NM_014057,NM_033014,NM_024416 CENPP,CENPP,OGN,OGN,OGN Silent,Silent,Silent,Silent,Silent rs2147060 9 95160477 [T/C] NM_001286969,NM_001012267,NM_014057,NM_033014,NM_024416 CENPP,CENPP,OGN,OGN,OGN Silent,Silent,Silent,Silent,Silent rs7032623 9 95171150 [A/G] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs10761156 9 95171852 [T/C] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs34154100 9 95177276 [A/C] NM_001286969,NM_001012267,NM_005014 CENPP,CENPP,OMD EXON Silent,Silent,Silent rs10992331 9 95182419 [T/C] NM_001286969,NM_001012267,NM_005014 CENPP,CENPP,OMD Silent,Silent,Silent rs10992332 9 95184788 [A/G] NM_001286969,NM_001012267,NM_005014 CENPP,CENPP,OMD Silent,Silent,Silent rs10992333 9 95185280 [A/G] NM_001286969,NM_001012267,NM_005014 CENPP,CENPP,OMD Silent,Silent,Silent rs10733744 9 95193001 [T/C] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs10125510 9 95196273 [T/C] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs17519719 9 95218599 [A/G] NM_001286969,NM_001012267,NM_001193335,NM_017680 CENPP,CENPP,ASPN,ASPN EXON Silent,Silent,Silent,Silent rs8067 9 95218829 [T/G] NM_001286969,NM_001012267,NM_001193335,NM_017680 CENPP,CENPP,ASPN,ASPN EXON Silent,Silent,Silent,Silent rs3174352 9 95219248 [A/G] NM_001286969,NM_001012267,NM_001193335,NM_017680 CENPP,CENPP,ASPN,ASPN EXON Silent,Silent,Silent,Silent rs10992348 9 95221475 [T/C] NM_001286969,NM_001012267,NM_001193335,NM_017680 CENPP,CENPP,ASPN,ASPN Silent,Silent,Silent,Silent rs13301537 9 95229047 [A/G] NM_001286969,NM_001012267,NM_001193335,NM_017680 CENPP,CENPP,ASPN,ASPN Silent,Silent,Silent,Silent rs3739606 9 95237222 [T/G] NM_001286969,NM_001012267,NM_001193335,NM_017680 CENPP,CENPP,ASPN,ASPN Silent,Silent,Silent,Silent rs10116241 9 95240546 [T/C] NM_001286969,NM_001012267,NM_001193335,NM_017680 CENPP,CENPP,ASPN,ASPN Silent,Silent,Silent,Silent rs331377 9 95243549 [A/G] NM_001286969,NM_001012267,NM_001193335,NM_017680 CENPP,CENPP,ASPN,ASPN Silent,Silent,Silent,Silent rs4744134 9 95246833 [A/G] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs331380 9 95256519 [T/C] NM_001286969,NM_001012267,NM_001197296 CENPP,CENPP,ECM2 Silent,Silent,Silent rs10429459 9 95258119 [A/G] NM_001286969,NM_001012267,NM_001197296,NM_001197295,NM_001393 CENPP,CENPP,ECM2,ECM2,ECM2 EXON Silent,Silent,Silent,Silent,Silent rs2296665 9 95271861 [T/C] NM_001286969,NM_001012267,NM_001197296,NM_001197295,NM_001393 CENPP,CENPP,ECM2,ECM2,ECM2 Silent,Silent,Silent,Silent,Silent rs2296667 9 95274338 [A/G] NM_001286969,NM_001012267,NM_001197296,NM_001197295,NM_001393 CENPP,CENPP,ECM2,ECM2,ECM2 EXON Silent,Silent,Synonymous_S353S,Synonymous_S353S,Synonymous_S375S rs2296668 9 95279588 [A/G] NM_001286969,NM_001012267,NM_001197296,NM_001197295,NM_001393 CENPP,CENPP,ECM2,ECM2,ECM2 Silent,Silent,Silent,Silent,Silent rs968040 9 95279985 [A/C] NM_001286969,NM_001012267,NM_001197296,NM_001197295,NM_001393 CENPP,CENPP,ECM2,ECM2,ECM2 EXON Silent,Silent,Synonymous_P155P,Synonymous_P155P,Synonymous_P155P rs10491806 9 95284212 [A/G] NM_001286969,NM_001012267,NM_001197296,NM_001197295,NM_001393 CENPP,CENPP,ECM2,ECM2,ECM2 Silent,Silent,Silent,Silent,Silent rs9299405 9 95284873 [A/G] NM_001286969,NM_001012267,NM_001197296,NM_001197295,NM_001393 CENPP,CENPP,ECM2,ECM2,ECM2 EXON Silent,Silent,Synonymous_S92S,Synonymous_S92S,Synonymous_S92S rs10120210 9 95284982 [T/G] NM_001286969,NM_001012267,NM_001197296,NM_001197295,NM_001393 CENPP,CENPP,ECM2,ECM2,ECM2 EXON Silent,Silent,Missense_Q56P,Missense_Q56P,Missense_Q56P rs10118939 9 95293641 [C/G] NM_001286969,NM_001012267,NM_001197296,NM_001197295,NM_001393 CENPP,CENPP,ECM2,ECM2,ECM2 Silent,Silent,Silent,Silent,Silent rs7036459 9 95309243 [T/C] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs10992367 9 95323135 [T/C] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs1536423 9 95323669 [T/C] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs7865019 9 95325631 [A/G] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs2131918 9 95353785 [T/C] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs7863882 9 95360764 [A/G] NM_001286969,NM_001012267 CENPP,CENPP Silent,Silent rs1874128 9 95362665 [A/G] NM_001286969,NM_001012267,NM_001286971 CENPP,CENPP,CENPP EXON Silent,Silent,Silent rs10992383 9 95366010 [T/C] NM_001286969,NM_001012267,NM_001286971 CENPP,CENPP,CENPP Silent,Silent,Silent rs7862970 9 95369531 [A/G] NM_001286969,NM_001012267,NM_001286971 CENPP,CENPP,CENPP Silent,Silent,Silent rs10992384 9 95372761 [A/G] NM_001286969,NM_001012267,NM_001286971 CENPP,CENPP,CENPP Silent,Silent,Silent rs1980705 9 95374368 [T/C] NM_001286969,NM_001012267,NM_001286971 CENPP,CENPP,CENPP Silent,Silent,Silent rs7030225 9 95378704 [A/G] NM_022755 IPPK Silent rs724102 9 95383290 [T/C] NM_022755 IPPK Silent rs1117670 9 95384198 [T/C] NM_022755 IPPK Silent rs1323523 9 95393049 [A/G] NM_022755 IPPK Silent rs2277168 9 95400370 [A/G] NM_022755 IPPK EXON Missense_R277W rs10992392 9 95419667 [A/G] NM_022755 IPPK Silent rs10992393 9 95420983 [A/G] NM_022755 IPPK Silent rs7863890 9 95425746 [A/G] NM_022755 IPPK Silent rs7849240 9 95427993 [T/C] NM_022755 IPPK Silent rs9969804 9 95429120 [A/C] NM_022755 IPPK Silent rs13285641 9 95443261 [A/G] rs10992420 9 95450808 [T/C] rs12345773 9 95461111 [T/C] rs10992427 9 95467111 [A/G] rs12686771 9 95472584 [T/C] rs556 9 95473719 [A/G] NM_001003800,NM_015250 BICD2,BICD2 EXON Silent,Silent rs3739605 9 95475937 [A/G] NM_001003800,NM_015250 BICD2,BICD2 EXON Silent,Silent rs3203916 9 95476958 [A/G] NM_001003800,NM_015250 BICD2,BICD2 EXON Silent,Silent rs10821009 9 95488414 [A/C] NM_001003800,NM_015250 BICD2,BICD2 Silent,Silent rs10821012 9 95502571 [A/G] NM_001003800,NM_015250 BICD2,BICD2 Silent,Silent rs7031163 9 95527885 [T/C] rs7043984 9 95529408 [T/C] rs10992469 9 95551617 [T/C] rs2181585 9 95551830 [A/G] rs7868651 9 95555939 [T/G] rs10992471 9 95559505 [A/G] rs1810696 9 95559852 [A/G] rs12554627 9 95560534 [A/G] rs7850075 9 95561537 [T/C] rs4141966 9 95572545 [T/G] NR_026868 ANKRD19P Silent rs10992480 9 95580376 [T/C] NR_026868 ANKRD19P Silent rs7038387 9 95583472 [T/C] NR_026868 ANKRD19P Silent rs1972214 9 95586719 [T/C] NR_026868 ANKRD19P Silent rs10821023 9 95590093 [T/G] NR_026868 ANKRD19P Silent rs7045305 9 95599825 [A/G] NR_026868 ANKRD19P EXON Silent rs3739602 9 95609564 [T/C] NM_001007101,NM_001354536,NM_001261460,NM_001354537,NM_001261459,NM_001261458,NM_031486 ZNF484,ZNF484,ZNF484,ZNF484,ZNF484,ZNF484,ZNF484 EXON Missense_G466D,Missense_G466D,Missense_G466D,Missense_G519D,Missense_G466D,Missense_G504D,Missense_G502D rs7859380 9 95616149 [T/C] NM_001007101,NM_001354536,NM_001261460,NM_001354537,NM_001261459,NM_001261458,NM_031486 ZNF484,ZNF484,ZNF484,ZNF484,ZNF484,ZNF484,ZNF484 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10761174 9 95618766 [T/C] NM_001007101,NM_001354536,NM_001261460,NM_001354537,NM_001261459,NM_001261458,NM_031486 ZNF484,ZNF484,ZNF484,ZNF484,ZNF484,ZNF484,ZNF484 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16908602 9 95620301 [T/G] NM_001007101,NM_001354536,NM_001261460,NM_001354537,NM_001261459,NM_001261458,NM_031486 ZNF484,ZNF484,ZNF484,ZNF484,ZNF484,ZNF484,ZNF484 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10739931 9 95621504 [T/C] NM_001007101,NM_001354536,NM_001261460,NM_001354537,NM_001261459,NM_001261458,NM_031486 ZNF484,ZNF484,ZNF484,ZNF484,ZNF484,ZNF484,ZNF484 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10992498 9 95624890 [A/C] NM_001007101,NM_001354536,NM_001261460,NM_001354537,NM_001261459,NM_001261458,NM_031486 ZNF484,ZNF484,ZNF484,ZNF484,ZNF484,ZNF484,ZNF484 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4744150 9 95630363 [T/C] NM_001007101,NM_001354536,NM_001261460,NM_001354537,NM_001261459,NM_001261458,NM_031486 ZNF484,ZNF484,ZNF484,ZNF484,ZNF484,ZNF484,ZNF484 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2281714 9 95647837 [A/G] NR_111003 LOC642943 EXON Silent rs10992512 9 95652951 [A/G] rs7035868 9 95683366 [T/G] rs10992535 9 95688099 [T/G] rs13294147 9 95691037 [A/G] rs10821041 9 95694499 [T/C] rs10992544 9 95696111 [A/G] rs7856228 9 95699292 [T/C] rs10992546 9 95700521 [A/C] rs10992548 9 95700701 [T/C] rs10821046 9 95708192 [T/C] rs6479442 9 95715717 [A/C] NM_001083536 FGD3 Silent rs7023321 9 95720621 [T/G] NM_001083536 FGD3 Silent rs16908676 9 95721674 [T/G] NM_001083536 FGD3 Silent rs7035881 9 95723163 [T/G] NM_001083536 FGD3 Silent rs4147166 9 95727883 [T/C] NM_001083536,NM_001286993 FGD3,FGD3 Silent,Silent rs9942965 9 95737649 [A/G] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 EXON Silent,Silent,Silent rs10992564 9 95746936 [A/G] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 Silent,Silent,Silent rs7850247 9 95747389 [T/C] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 Silent,Silent,Silent rs10992568 9 95753319 [T/C] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 Silent,Silent,Silent rs7043408 9 95766949 [T/C] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 Silent,Silent,Silent rs4744164 9 95767060 [T/C] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 Silent,Silent,Silent rs10761188 9 95770161 [A/G] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 Silent,Silent,Silent rs10761189 9 95772228 [A/G] NM_001083536,NM_001286993,NM_033086,NR_121565 FGD3,FGD3,FGD3,LOC101927954 EXON Silent,Silent,Silent,Silent rs3934851 9 95775561 [T/C] NM_001083536,NM_001286993,NM_033086,NR_121565 FGD3,FGD3,FGD3,LOC101927954 EXON Silent,Silent,Silent,Silent rs10761191 9 95781040 [T/C] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 Silent,Silent,Silent rs11790517 9 95782667 [T/C] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 EXON Synonymous_F485F,Synonymous_F485F,Synonymous_F485F rs7855476 9 95785819 [T/C] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 Silent,Silent,Silent rs7854887 9 95786065 [A/G] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 Silent,Silent,Silent rs11788432 9 95788623 [T/C] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 Silent,Silent,Silent rs10992587 9 95789769 [A/G] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 Silent,Silent,Silent rs13290740 9 95793816 [A/G] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 Silent,Silent,Silent rs7022396 9 95797446 [T/C] NM_001083536,NM_001286993,NM_033086 FGD3,FGD3,FGD3 Silent,Silent,Silent rs6479447 9 95799446 [T/C] rs11787849 9 95802287 [T/C] rs4573339 9 95806365 [A/G] rs10992608 9 95806823 [A/G] rs7027092 9 95812707 [A/G] rs4744167 9 95818641 [T/C] rs10992619 9 95823747 [T/C] NM_001287006,NM_145006,NM_001287007,NM_001287008,NM_001287005 SUSD3,SUSD3,SUSD3,SUSD3,SUSD3 Silent,Silent,Silent,Silent,Silent rs10992622 9 95830197 [A/G] NM_001287006,NM_145006,NM_001287007,NM_001287008,NM_001287005 SUSD3,SUSD3,SUSD3,SUSD3,SUSD3 Silent,Silent,Silent,Silent,Silent rs4422825 9 95832650 [A/G] NM_001287006,NM_145006,NM_001287007,NM_001287008,NM_001287005 SUSD3,SUSD3,SUSD3,SUSD3,SUSD3 Silent,Silent,Silent,Silent,Silent rs7018579 9 95834985 [A/G] NM_001287006,NM_145006,NM_001287007,NM_001287008,NM_001287005 SUSD3,SUSD3,SUSD3,SUSD3,SUSD3 Silent,Silent,Silent,Silent,Silent rs10761192 9 95839418 [A/C] NM_001287006,NM_145006,NM_001287007,NM_001287008,NM_001287005 SUSD3,SUSD3,SUSD3,SUSD3,SUSD3 Silent,Silent,Silent,Silent,Silent rs1131773 9 95840256 [A/G] NM_001287006,NM_145006,NM_001287007,NM_001287008,NM_001287005 SUSD3,SUSD3,SUSD3,SUSD3,SUSD3 EXON Missense_K136E,Missense_K136E,Missense_K73E,Missense_K73E,Missense_K123E rs9696357 9 95845152 [T/C] NM_001287006,NM_145006,NM_001287007,NM_001287008,NM_001287005 SUSD3,SUSD3,SUSD3,SUSD3,SUSD3 Silent,Silent,Silent,Silent,Silent rs10992629 9 95854444 [A/G] rs10992630 9 95855100 [A/G] rs13288200 9 95857333 [A/G] rs4237219 9 95860100 [A/G] NR_134466,NR_134465,NM_001318011,NM_001318010,NR_134468,NM_032310,NR_134464,NR_134467 CARD19,CARD19,CARD19,CARD19,CARD19,CARD19,CARD19,CARD19 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4744171 9 95860415 [A/G] NR_134466,NR_134465,NM_001318011,NM_001318010,NR_134468,NM_032310,NR_134464,NR_134467 CARD19,CARD19,CARD19,CARD19,CARD19,CARD19,CARD19,CARD19 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4744175 9 95869726 [A/G] NR_134466,NR_134465,NM_001318011,NM_001318010,NR_134468,NM_032310,NR_134464,NR_134467 CARD19,CARD19,CARD19,CARD19,CARD19,CARD19,CARD19,CARD19 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2275849 9 95869943 [T/C] NR_134466,NR_134465,NM_001318011,NM_001318010,NR_134468,NM_032310,NR_134464,NR_134467 CARD19,CARD19,CARD19,CARD19,CARD19,CARD19,CARD19,CARD19 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17593496 9 95872885 [T/C] NR_134466,NR_134465,NM_001318011,NM_001318010,NR_134468,NM_032310,NR_134464,NR_134467 CARD19,CARD19,CARD19,CARD19,CARD19,CARD19,CARD19,CARD19 EXON Silent,Silent,Synonymous_L62L,Silent,Silent,Synonymous_L62L,Silent,Silent rs12343422 9 95873388 [T/C] NR_134466,NR_134465,NM_001318011,NM_001318010,NR_134468,NM_032310,NR_134464,NR_134467 CARD19,CARD19,CARD19,CARD19,CARD19,CARD19,CARD19,CARD19 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12003264 9 95875447 [T/C] NR_134466,NR_134465,NM_001318011,NM_001318010,NR_134468,NM_032310,NR_134464,NR_134467 CARD19,CARD19,CARD19,CARD19,CARD19,CARD19,CARD19,CARD19 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2895245 9 95877110 [T/C] rs3802386 9 95879087 [T/G] rs13285107 9 95881054 [T/C] rs1954435 9 95883363 [A/G] rs2275848 9 95887320 [T/G] NM_004148 NINJ1 EXON Missense_A110D rs12235416 9 95888667 [T/C] NM_004148 NINJ1 Silent rs7025554 9 95898531 [T/C] rs10821076 9 95899771 [A/G] rs4743894 9 95905552 [A/C] rs4744180 9 95906804 [T/C] rs6479457 9 95910508 [T/C] rs4335184 9 95912016 [T/G] rs10821077 9 95917252 [T/G] rs10992658 9 95918643 [A/G] rs12378014 9 95919314 [T/C] rs2398828 9 95919865 [T/C] rs6479458 9 95930334 [A/G] rs10821080 9 95930572 [T/C] rs4743898 9 95931685 [T/C] rs2398821 9 95939766 [A/G] rs10821083 9 95951477 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs7041800 9 95951769 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs10992671 9 95952870 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs10512222 9 95953341 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs7858813 9 95955365 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs7031721 9 95955986 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs6479466 9 95958095 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs12336667 9 95962890 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs10992674 9 95963114 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs1539669 9 95971876 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs7873162 9 95983986 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs4744195 9 95985281 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs4617217 9 95988968 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs4744199 9 95990501 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs7874101 9 95991895 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs7048527 9 95993170 [A/G] NM_006648,NM_001282394 WNK2,WNK2 EXON Synonymous_T285T,Synonymous_T285T rs11787888 9 95993326 [T/C] NM_006648,NM_001282394 WNK2,WNK2 EXON Synonymous_S337S,Synonymous_S337S rs11793893 9 95994155 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs7864826 9 95994554 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs2398820 9 95996573 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs1539670 9 96000622 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs11788911 9 96000921 [A/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs7022051 9 96002983 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs12341303 9 96003435 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs12554664 9 96011635 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs12554962 9 96012145 [T/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs4744201 9 96015256 [T/C] NM_006648,NM_001282394 WNK2,WNK2 EXON Synonymous_D642D,Synonymous_D642D rs10992689 9 96017751 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs10761202 9 96019970 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs1110335 9 96022116 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs4744213 9 96038524 [T/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs1931367 9 96041713 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs2306183 9 96052179 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs1889339 9 96053928 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs1111776 9 96061269 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs16936750 9 96063456 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs12341311 9 96063653 [A/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs10992701 9 96068234 [T/G] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs16909016 9 96068328 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs10761208 9 96072452 [T/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs10761209 9 96077465 [A/C] NM_006648,NM_001282394 WNK2,WNK2 Silent,Silent rs6479474 9 96082752 [T/G] NM_006648,NM_001098808 WNK2,C9orf129 EXON Silent,Silent rs13293217 9 96082919 [A/G] NM_001098808 C9orf129 Silent rs10821109 9 96091688 [T/G] NM_001098808 C9orf129 Silent rs3933798 9 96093535 [T/C] NM_001098808 C9orf129 Silent rs4633120 9 96093865 [T/G] NM_001098808 C9orf129 Silent rs4534181 9 96093924 [A/G] NM_001098808 C9orf129 Silent rs10992707 9 96094499 [T/C] NM_001098808 C9orf129 Silent rs2991377 9 96094943 [T/C] NM_001098808 C9orf129 Silent rs2927567 9 96096243 [A/C] NM_001098808 C9orf129 Silent rs2927572 9 96099377 [A/G] NM_001098808 C9orf129 Silent rs10761215 9 96117149 [T/C] rs10761216 9 96117348 [T/C] rs4744226 9 96125819 [A/G] rs4744227 9 96126075 [T/C] rs10992715 9 96133597 [A/G] rs1931371 9 96138557 [A/G] rs7867386 9 96143058 [A/G] rs2086106 9 96144349 [T/C] rs10821119 9 96145271 [A/C] rs10739948 9 96150272 [T/C] rs11999013 9 96154352 [A/C] rs2266010 9 96158277 [T/C] rs7020852 9 96163260 [T/C] rs999326 9 96163325 [T/C] rs10761224 9 96166579 [A/G] rs10821123 9 96169561 [A/G] rs2184255 9 96176203 [A/G] rs13287066 9 96178967 [A/G] rs12379660 9 96182487 [A/G] rs944990 9 96191004 [T/C] rs2249747 9 96192620 [T/C] rs11789176 9 96196166 [T/C] rs7036984 9 96200540 [A/G] rs10821128 9 96209943 [T/C] NR_136230,NR_136237,NR_136234,NR_136232,NR_136236,NR_136233,NM_198841,NR_136229,NR_136238,NR_136231,NR_136235,NM_001322224 FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS EXON Silent,Silent,Silent,Silent,Silent,Silent,Missense_K241E,Silent,Silent,Silent,Silent,Missense_K59E rs10992740 9 96213291 [A/G] NR_136230,NR_136237,NR_136234,NR_136232,NR_136236,NR_136233,NM_198841,NR_136229,NR_136238,NR_136231,NR_136235,NM_001322224 FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1055710 9 96214928 [A/G] NR_136230,NM_198841,NR_136229,NR_136231,NM_014612,NM_001286724,NM_001286722,NM_001286723 FAM120AOS,FAM120AOS,FAM120AOS,FAM120AOS,FAM120A,FAM120A,FAM120A,FAM120A EXON Silent,Missense_L22F,Silent,Silent,Silent,Silent,Silent,Silent rs12344021 9 96220114 [T/C] NM_014612,NM_001286724,NM_001286722,NM_001286723 FAM120A,FAM120A,FAM120A,FAM120A Silent,Silent,Silent,Silent rs10512225 9 96227100 [A/G] NM_014612,NM_001286724,NM_001286722,NM_001286723 FAM120A,FAM120A,FAM120A,FAM120A Silent,Silent,Silent,Silent rs10821131 9 96228822 [T/C] NM_014612,NM_001286724,NM_001286722,NM_001286723 FAM120A,FAM120A,FAM120A,FAM120A Silent,Silent,Silent,Silent rs10821132 9 96228952 [A/G] NM_014612,NM_001286724,NM_001286722,NM_001286723 FAM120A,FAM120A,FAM120A,FAM120A Silent,Silent,Silent,Silent rs10512224 9 96229440 [T/G] NM_014612,NM_001286724,NM_001286722,NM_001286723 FAM120A,FAM120A,FAM120A,FAM120A Silent,Silent,Silent,Silent rs10992747 9 96232402 [A/G] NM_014612,NM_001286724,NM_001286722,NM_001286723 FAM120A,FAM120A,FAM120A,FAM120A Silent,Silent,Silent,Silent rs10821134 9 96238218 [T/C] NM_014612,NM_001286724,NM_001286722,NM_001286723 FAM120A,FAM120A,FAM120A,FAM120A Silent,Silent,Silent,Silent rs4744244 9 96242455 [T/C] NM_014612,NM_001286724,NM_001286722,NM_001286723 FAM120A,FAM120A,FAM120A,FAM120A Silent,Silent,Silent,Silent rs7025805 9 96243745 [A/G] NM_014612,NM_001286724,NM_001286722,NM_001286723 FAM120A,FAM120A,FAM120A,FAM120A Silent,Silent,Silent,Silent rs10821144 9 96265258 [T/C] NM_014612,NM_001286724,NM_001286722,NM_001286723 FAM120A,FAM120A,FAM120A,FAM120A Silent,Silent,Silent,Silent rs10992765 9 96270954 [A/C] NM_014612,NM_001286724,NM_001286722,NM_001286723 FAM120A,FAM120A,FAM120A,FAM120A Silent,Silent,Silent,Silent rs4744250 9 96271752 [A/G] NM_014612,NM_001286724,NM_001286722,NM_001286723 FAM120A,FAM120A,FAM120A,FAM120A Silent,Silent,Silent,Silent rs7019001 9 96291224 [A/G] NM_014612,NM_001286724,NM_001286722,NM_001286723 FAM120A,FAM120A,FAM120A,FAM120A Silent,Silent,Silent,Silent rs10821160 9 96326127 [T/C] NM_014612,NM_001286722 FAM120A,FAM120A Silent,Silent rs7023577 9 96336993 [T/C] rs1000850 9 96347718 [A/G] NM_005392 PHF2 Silent rs10123412 9 96351480 [A/G] NM_005392 PHF2 Silent rs10821166 9 96351923 [A/G] NM_005392 PHF2 Silent rs2150752 9 96353119 [T/G] NM_005392 PHF2 Silent rs10122014 9 96353485 [T/C] NM_005392 PHF2 Silent rs10116422 9 96357739 [A/C] NM_005392 PHF2 Silent rs10761239 9 96359884 [T/C] NM_005392 PHF2 Silent rs2254389 9 96366415 [A/G] NM_005392 PHF2 Silent rs2994369 9 96366513 [T/C] NM_005392 PHF2 Silent rs10123378 9 96375217 [T/C] NM_005392 PHF2 Silent rs9409478 9 96379505 [A/G] NM_005392 PHF2 Silent rs12551314 9 96379797 [A/C] NM_005392 PHF2 Silent rs7033146 9 96382100 [T/C] NM_005392 PHF2 Silent rs7033439 9 96382336 [T/C] NM_005392 PHF2 Silent rs7849752 9 96391990 [T/G] NM_005392 PHF2 Silent rs11534279 9 96401464 [A/G] NM_005392 PHF2 Silent rs10761247 9 96403367 [A/G] NM_005392 PHF2 Silent rs12235863 9 96411956 [T/C] NM_005392 PHF2 Silent rs11793637 9 96415899 [A/G] NM_005392 PHF2 Silent rs3750358 9 96425138 [T/C] NM_005392 PHF2 Silent rs10992839 9 96427505 [T/C] NM_005392 PHF2 Silent rs1132004 9 96440808 [A/C] NM_005392 PHF2 EXON Silent rs12552323 9 96442814 [A/C] rs7023781 9 96447178 [T/C] rs17535326 9 96448367 [T/C] rs4287000 9 96451784 [A/G] rs10992867 9 96461013 [A/G] rs10992869 9 96462632 [A/G] rs12683791 9 96463094 [T/C] rs4744272 9 96469075 [A/G] rs10992883 9 96483140 [T/C] rs11794188 9 96484209 [A/G] rs2398871 9 96484220 [T/C] rs10992886 9 96488780 [T/C] rs10821207 9 96488923 [T/G] rs16909421 9 96490009 [A/C] rs2255840 9 96493773 [A/C] rs7049001 9 96493970 [T/C] rs2490997 9 96522109 [T/C] rs2490996 9 96522775 [T/C] rs10761266 9 96524226 [A/G] rs12351676 9 96526835 [T/C] rs2487013 9 96531707 [A/C] rs10119990 9 96534118 [A/G] rs2490992 9 96534292 [T/C] rs12685281 9 96535981 [A/G] rs10821216 9 96544917 [T/C] rs7874836 9 96559370 [T/C] rs7027203 9 96562563 [A/C] rs10761275 9 96563349 [A/G] rs10821224 9 96564575 [A/C] rs10761280 9 96569343 [A/G] rs7854075 9 96571211 [A/G] rs4744283 9 96577178 [T/C] rs11999651 9 96578169 [A/G] rs11789114 9 96582511 [T/C] rs4744285 9 96583746 [T/G] rs3996253 9 96591066 [T/C] rs10992913 9 96591546 [T/C] rs4344139 9 96600298 [T/C] rs3957512 9 96612770 [A/G] rs10821237 9 96614312 [T/C] rs10821238 9 96617463 [T/C] rs10992927 9 96617700 [T/G] rs4428725 9 96623453 [T/G] rs4075732 9 96624526 [A/C] rs4075733 9 96624645 [T/C] rs10733750 9 96630555 [T/C] rs10115047 9 96631287 [T/C] rs10114476 9 96631459 [A/C] rs10117869 9 96631796 [A/G] rs9644971 9 96635264 [T/C] rs7855646 9 96644841 [A/G] rs11793716 9 96646070 [T/C] rs2185110 9 96648679 [A/C] rs12376257 9 96654346 [A/G] rs11794892 9 96654597 [A/G] rs10992966 9 96658325 [A/G] rs1890376 9 96661535 [A/C] rs7047570 9 96663863 [A/G] rs1890379 9 96665767 [A/G] rs10117505 9 96670213 [A/G] rs12343357 9 96671646 [T/C] rs7872495 9 96671698 [T/C] rs10119262 9 96672124 [A/G] rs13283140 9 96679166 [T/C] rs10992979 9 96679448 [A/G] rs12353447 9 96680040 [A/G] rs12380877 9 96680113 [A/G] rs4743938 9 96681388 [A/G] rs10821266 9 96682611 [A/G] rs12156596 9 96682813 [T/C] rs10992984 9 96685120 [A/G] rs12376441 9 96685308 [T/C] rs7028921 9 96691023 [A/G] rs12341268 9 96693709 [A/G] rs1933678 9 96697234 [T/C] rs10992995 9 96699676 [A/G] rs1933679 9 96709022 [A/G] rs1933680 9 96709483 [T/C] rs10821272 9 96709839 [T/C] rs11793324 9 96713690 [T/C] rs1057713 9 96714161 [A/G] NM_021570 BARX1 EXON Silent rs12684081 9 96714981 [A/G] NM_021570 BARX1 Silent rs11789015 9 96716028 [A/G] NM_021570 BARX1 Silent rs7872123 9 96716158 [T/C] NM_021570 BARX1 Silent rs1933670 9 96736704 [A/G] rs10821278 9 96740079 [A/C] rs10821279 9 96741641 [T/C] rs987511 9 96757868 [A/G] rs10993017 9 96760384 [T/C] rs1411861 9 96763614 [A/G] rs1331219 9 96766248 [A/G] rs10761312 9 96769237 [A/G] rs4743942 9 96773760 [A/G] rs7852992 9 96774518 [T/C] rs2150624 9 96776609 [T/C] rs10116489 9 96792054 [A/G] rs7047684 9 96792790 [T/C] rs10116746 9 96795797 [T/C] NM_177995,NM_001253830 PTPDC1,PTPDC1 Silent,Silent rs1766923 9 96802897 [A/G] NM_177995,NM_001253830 PTPDC1,PTPDC1 Silent,Silent rs10429556 9 96805635 [T/C] NM_177995,NM_001253830 PTPDC1,PTPDC1 Silent,Silent rs10125538 9 96821924 [T/C] NM_177995,NM_001253830 PTPDC1,PTPDC1 Silent,Silent rs1539282 9 96827424 [T/C] NM_177995,NM_001253830 PTPDC1,PTPDC1 Silent,Silent rs6479526 9 96830635 [T/C] NM_177995,NM_001253830 PTPDC1,PTPDC1 Silent,Silent rs7020044 9 96837996 [T/G] NM_177995,NM_001253830 PTPDC1,PTPDC1 Silent,Silent rs7042611 9 96842557 [A/C] NM_177995,NM_001253830 PTPDC1,PTPDC1 Silent,Silent rs4744313 9 96846061 [T/C] NM_177995,NM_001253830 PTPDC1,PTPDC1 Silent,Silent rs10993047 9 96846500 [T/C] NM_177995,NM_001253830 PTPDC1,PTPDC1 Silent,Silent rs6479527 9 96858411 [A/G] NM_177995,NM_001253830,NM_001253829,NM_152422 PTPDC1,PTPDC1,PTPDC1,PTPDC1 Silent,Silent,Silent,Silent rs10993052 9 96861798 [T/C] NM_177995,NM_001253830,NM_001253829,NM_152422 PTPDC1,PTPDC1,PTPDC1,PTPDC1 Silent,Silent,Silent,Silent rs10122334 9 96864227 [A/G] NM_177995,NM_001253830,NM_001253829,NM_152422 PTPDC1,PTPDC1,PTPDC1,PTPDC1 Silent,Silent,Silent,Silent rs10821295 9 96869147 [A/G] NM_177995,NM_001253830,NM_001253829,NM_152422 PTPDC1,PTPDC1,PTPDC1,PTPDC1 Silent,Silent,Silent,Silent rs10993058 9 96873151 [A/C] rs7875583 9 96883271 [T/C] rs3909256 9 96889505 [T/C] rs3858085 9 96893369 [A/G] rs7035599 9 96893543 [A/G] rs10821299 9 96895108 [T/G] rs10739970 9 96896292 [A/G] rs2398901 9 96897033 [A/G] rs10761317 9 96898436 [T/C] rs959802 9 96902444 [T/C] rs10993068 9 96906751 [T/C] rs13439971 9 96913764 [A/G] rs10512230 9 96916230 [T/G] rs10114341 9 96919182 [T/C] rs1362820 9 96930485 [T/C] rs2026618 9 96931807 [A/G] rs10993081 9 96939718 [A/G] NR_046165,NR_046163 LINC02603,LINC02603 EXON Silent,Silent rs10821312 9 96944581 [A/G] NR_046165,NR_046163 LINC02603,LINC02603 Silent,Silent rs10512231 9 96945748 [T/C] NR_046165,NR_046163 LINC02603,LINC02603 Silent,Silent rs10116369 9 96946670 [T/C] NR_046165,NR_046163 LINC02603,LINC02603 Silent,Silent rs7038156 9 96959415 [A/G] NR_046165,NR_046163 LINC02603,LINC02603 Silent,Silent rs7872931 9 96970197 [A/G] rs12379483 9 96973995 [T/C] rs16909728 9 96974302 [T/C] rs9409706 9 96990968 [T/C] rs2675278 9 97000398 [T/C] rs7029157 9 97000863 [T/C] rs2675275 9 97008212 [T/C] rs10993117 9 97015630 [T/C] rs9299416 9 97016558 [T/C] rs11789548 9 97017858 [A/G] rs10821325 9 97018657 [T/C] rs10993121 9 97024028 [T/C] NM_194320,NM_001301275,NM_003448 ZNF169,ZNF169,ZNF169 Silent,Silent,Silent rs3118766 9 97025298 [T/G] NM_194320,NM_001301275,NM_003448 ZNF169,ZNF169,ZNF169 Silent,Silent,Silent rs11793128 9 97040683 [A/G] NM_194320,NM_001301275,NM_003448 ZNF169,ZNF169,ZNF169 Silent,Silent,Silent rs10435926 9 97042132 [T/C] NM_194320,NM_001301275,NM_003448 ZNF169,ZNF169,ZNF169 Silent,Silent,Silent rs3118752 9 97052841 [A/G] NM_194320,NM_001301275,NM_003448 ZNF169,ZNF169,ZNF169 Silent,Silent,Silent rs3118749 9 97053678 [T/C] NM_194320,NM_001301275,NM_003448 ZNF169,ZNF169,ZNF169 Silent,Silent,Silent rs1536690 9 97055310 [T/C] NM_194320,NM_001301275,NM_003448 ZNF169,ZNF169,ZNF169 EXON Missense_P72L,Silent,Missense_P72L rs3131910 9 97056183 [A/C] NM_194320,NM_001301275,NM_003448 ZNF169,ZNF169,ZNF169 Silent,Silent,Silent rs1064560 9 97057814 [A/G] NM_194320,NM_001301275,NM_003448 ZNF169,ZNF169,ZNF169 Silent,Silent,Silent rs12343413 9 97061544 [A/G] NM_194320,NM_001301275,NM_003448 ZNF169,ZNF169,ZNF169 Silent,Silent,Silent rs9409511 9 97061577 [A/G] NM_194320,NM_001301275,NM_003448 ZNF169,ZNF169,ZNF169 Silent,Silent,Silent rs12236219 9 97062981 [T/C] NM_194320,NM_001301275,NM_003448 ZNF169,ZNF169,ZNF169 EXON Missense_R381C,Missense_R190C,Missense_R382C rs12350212 9 97063628 [C/G] NM_194320,NM_001301275,NM_003448 ZNF169,ZNF169,ZNF169 EXON Missense_Q596H,Missense_Q405H,Missense_Q597H rs7042481 9 97064273 [A/C] rs9299419 9 97066584 [T/C] rs10993161 9 97068939 [A/C] rs2479587 9 97072647 [T/G] rs9409727 9 97107088 [A/C] NR_033937 LOC100132077 Silent rs9696076 9 97123522 [A/G] rs2987202 9 97136378 [A/G] rs7019137 9 97150348 [A/G] NM_032558 MFSD14B Silent rs10993188 9 97161890 [A/G] NM_032558 MFSD14B Silent rs1752784 9 97177826 [T/C] NM_032558 MFSD14B Silent rs16910109 9 97208231 [A/G] NM_032558 MFSD14B Silent rs7037298 9 97216163 [T/G] NM_032558 MFSD14B Silent rs9409765 9 97221434 [A/G] NM_032558 MFSD14B Silent rs7863750 9 97221463 [A/G] NM_032558 MFSD14B EXON Synonymous_P430P rs9409552 9 97228918 [A/G] rs7020879 9 97242304 [T/C] rs9409562 9 97246817 [A/G] rs9409567 9 97252505 [A/G] rs7031088 9 97253578 [A/C] rs10821352 9 97257314 [A/G] rs6479549 9 97257732 [T/C] rs9409787 9 97261572 [A/G] rs12343547 9 97278389 [A/G] rs12236456 9 97279870 [T/C] rs12342274 9 97280338 [T/C] rs9299425 9 97283226 [A/G] rs2772020 9 97286964 [T/G] rs605323 9 97290466 [A/G] rs543731 9 97310865 [A/G] rs10761333 9 97312584 [A/C] rs1048510 9 97321127 [T/C] NR_121567,NR_121569,NR_121568,NR_121566,NM_003837 PCAT7,PCAT7,PCAT7,PCAT7,FBP2 EXON Silent,Silent,Silent,Silent,Silent rs1543185 9 97321172 [T/C] NR_121567,NR_121569,NR_121568,NR_121566,NM_003837 PCAT7,PCAT7,PCAT7,PCAT7,FBP2 EXON Silent,Silent,Silent,Silent,Silent rs965474 9 97324198 [A/G] NR_121567,NR_121569,NR_121568,NR_121566,NM_003837 PCAT7,PCAT7,PCAT7,PCAT7,FBP2 Silent,Silent,Silent,Silent,Silent rs6479554 9 97325998 [A/G] NR_121567,NR_121569,NR_121568,NR_121566,NM_003837 PCAT7,PCAT7,PCAT7,PCAT7,FBP2 Silent,Silent,Silent,Silent,Silent rs10761339 9 97328313 [A/G] NR_121567,NR_121569,NR_121568,NR_121566,NM_003837 PCAT7,PCAT7,PCAT7,PCAT7,FBP2 Silent,Silent,Silent,Silent,Silent rs609901 9 97330693 [T/G] NR_121567,NR_121569,NR_121568,NR_121566,NM_003837 PCAT7,PCAT7,PCAT7,PCAT7,FBP2 EXON Silent,Silent,Silent,Silent,Silent rs3852401 9 97333275 [A/G] NM_003837 FBP2 Silent rs3864790 9 97334274 [A/G] NM_003837 FBP2 Silent rs1754432 9 97337835 [T/C] NM_003837 FBP2 Silent rs7870433 9 97343620 [T/C] NM_003837 FBP2 Silent rs663385 9 97343939 [T/C] NM_003837 FBP2 Silent rs802918 9 97345467 [A/G] NM_003837 FBP2 Silent rs10739976 9 97346437 [T/C] NM_003837 FBP2 Silent rs2280303 9 97349147 [T/C] NM_003837 FBP2 Silent rs2280302 9 97349520 [T/C] NM_003837 FBP2 Silent rs2280301 9 97349591 [T/G] NM_003837 FBP2 EXON Synonymous_R111R rs548348 9 97354528 [A/G] NM_003837 FBP2 Silent rs2987900 9 97355470 [A/G] NM_003837 FBP2 Silent rs601389 9 97360148 [T/C] rs9695 9 97365642 [A/G] NM_001127628,NM_000507 FBP1,FBP1 EXON Silent,Silent rs1754436 9 97366400 [T/C] NM_001127628,NM_000507 FBP1,FBP1 Silent,Silent rs1769259 9 97369149 [T/C] NM_001127628,NM_000507 FBP1,FBP1 EXON Missense_R218K,Missense_R218K rs8192689 9 97380043 [A/G] NM_001127628,NM_000507 FBP1,FBP1 Silent,Silent rs7867069 9 97380597 [A/G] NM_001127628,NM_000507 FBP1,FBP1 Silent,Silent rs10993269 9 97388953 [T/G] NM_001127628,NM_000507 FBP1,FBP1 Silent,Silent rs4129220 9 97390098 [A/G] NM_001127628,NM_000507 FBP1,FBP1 Silent,Silent rs4129219 9 97390288 [T/C] NM_001127628,NM_000507 FBP1,FBP1 Silent,Silent rs16910850 9 97398792 [T/C] NM_001127628,NM_000507 FBP1,FBP1 Silent,Silent rs7031924 9 97403254 [A/G] rs10761350 9 97407889 [A/G] rs7035325 9 97409437 [A/G] rs10993280 9 97409771 [T/C] rs10993282 9 97412037 [T/C] rs913185 9 97415529 [A/C] rs12685159 9 97419146 [A/C] rs6479562 9 97429160 [A/G] rs10081702 9 97430831 [T/C] rs4460442 9 97443341 [A/C] rs10125337 9 97444038 [T/C] rs12335609 9 97445112 [T/C] rs10124217 9 97447430 [T/C] rs7044668 9 97459005 [A/G] rs12554486 9 97463435 [T/G] rs12349751 9 97464381 [A/G] rs12344604 9 97466882 [T/C] rs6479565 9 97476866 [A/G] rs396538 9 97487704 [A/G] rs7851726 9 97503985 [T/C] NM_001193331,NM_032823 C9orf3,C9orf3 Silent,Silent rs7866848 9 97505608 [A/G] NM_001193331,NM_032823 C9orf3,C9orf3 Silent,Silent rs3802462 9 97522464 [T/C] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 EXON Synonymous_D133D,Synonymous_D133D,Synonymous_D133D rs16911679 9 97522600 [A/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 EXON Missense_V179I,Missense_V179I,Missense_V179I rs16911681 9 97522829 [A/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 EXON Missense_R255Q,Missense_R255Q,Missense_R255Q rs12341814 9 97522915 [A/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs438742 9 97532364 [A/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs10512235 9 97549812 [A/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs4744376 9 97577092 [A/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs10732405 9 97586542 [T/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs7847277 9 97613428 [A/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs10993371 9 97618000 [T/C] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs7870679 9 97620741 [A/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs10993381 9 97639463 [T/C] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs1542107 9 97642419 [A/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs3886568 9 97645590 [T/C] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs4385527 9 97648587 [A/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs7019602 9 97651128 [T/C] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs10993387 9 97662496 [T/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs16911802 9 97666682 [T/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs10993391 9 97675840 [A/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs12235316 9 97677556 [A/G] NM_001193331,NM_032823,NM_001193329 C9orf3,C9orf3,C9orf3 Silent,Silent,Silent rs12344211 9 97691104 [T/C] NM_001193331,NM_032823,NM_001193329,NR_147614,NR_147613 C9orf3,C9orf3,C9orf3,LOC101928119,LOC101928119 EXON Silent,Silent,Silent,Silent,Silent rs2026399 9 97700731 [A/G] NM_032823,NM_001193329,NR_147614,NR_147613 C9orf3,C9orf3,LOC101928119,LOC101928119 Silent,Silent,Silent,Silent rs2095069 9 97702500 [T/C] NM_032823,NM_001193329,NR_147614,NR_147613 C9orf3,C9orf3,LOC101928119,LOC101928119 Silent,Silent,Silent,Silent rs7852735 9 97715088 [A/G] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs2404295 9 97723868 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs10993413 9 97729136 [A/G] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs16911887 9 97734605 [A/G] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs10993422 9 97735639 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs10993428 9 97738174 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs10993429 9 97739465 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs7866661 9 97749379 [T/G] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs7024881 9 97750555 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs7042271 9 97754447 [A/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs10993446 9 97759920 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs12686500 9 97760654 [A/G] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs10761364 9 97768286 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs3802456 9 97771852 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs1571897 9 97781919 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs10993456 9 97783630 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs7023719 9 97785248 [A/G] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs12684404 9 97785929 [A/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs7022739 9 97788207 [A/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs1020963 9 97789745 [A/G] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs2061799 9 97795004 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs1871220 9 97819743 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs1888944 9 97822941 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs4744435 9 97831471 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs4744436 9 97831581 [A/G] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs10761374 9 97834573 [T/C] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs10491560 9 97844513 [A/G] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs10821447 9 97845505 [A/G] NM_032823,NM_001193329 C9orf3,C9orf3 Silent,Silent rs4657 9 97849090 [A/G] NM_032823,NM_001193329 C9orf3,C9orf3 EXON Silent,Silent rs9673 9 97861437 [A/G] NM_001243743,NM_000136 FANCC,FANCC EXON Silent,Silent rs4647556 9 97862327 [A/G] NM_001243743,NM_000136 FANCC,FANCC EXON Silent,Silent rs1800367 9 97869536 [T/C] NM_001243743,NM_000136 FANCC,FANCC EXON Missense_V449M,Missense_V449M rs4647516 9 97887988 [A/C] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs4647505 9 97898072 [A/G] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs3780567 9 97898220 [A/G] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs640628 9 97913026 [A/G] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs475413 9 97920712 [T/C] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs565293 9 97923592 [A/G] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs657637 9 97928719 [A/C] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs1800360 9 97934367 [T/C] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC EXON Synonymous_Q136Q,Synonymous_Q136Q,Synonymous_Q136Q rs2297597 9 97940807 [T/C] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs16912021 9 97948882 [A/C] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs12380720 9 97989207 [T/C] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs16912035 9 97992323 [A/G] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs13292454 9 97995075 [A/G] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs1326188 9 97998601 [T/G] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs4647432 9 98004495 [A/C] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs356659 9 98006368 [T/C] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs4647382 9 98058759 [T/C] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs356665 9 98060631 [T/C] NM_001243743,NM_000136,NM_001243744 FANCC,FANCC,FANCC Silent,Silent,Silent rs4647350 9 98079803 [T/C] NM_000136,NM_001243744 FANCC,FANCC Silent,Silent rs10993512 9 98094129 [A/G] rs4743993 9 98102983 [T/C] rs6479604 9 98110248 [A/G] rs10761384 9 98122445 [T/C] rs2036516 9 98131102 [T/C] rs357547 9 98138938 [A/G] rs357542 9 98143642 [T/C] rs357539 9 98146478 [T/G] rs7860361 9 98147804 [T/C] rs12348774 9 98155862 [T/C] rs357527 9 98167811 [A/G] rs10761388 9 98171401 [A/G] rs7388704 9 98171417 [A/G] rs2026077 9 98175928 [T/G] rs357561 9 98177173 [T/C] rs16912133 9 98177956 [A/G] rs16912143 9 98181517 [A/C] rs357522 9 98189458 [A/G] rs357563 9 98204199 [T/C] rs16909859 9 98204792 [A/G] rs16909865 9 98207302 [C/G] NM_001083604,NM_001354918,NM_001083603,NM_001083606,NM_000264,NM_001083602,NR_149061,NM_001083605,NM_001083607 PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs357564 9 98209594 [A/G] NM_001083604,NM_001354918,NM_001083603,NM_001083606,NM_000264,NM_001083602,NR_149061,NM_001083605,NM_001083607 PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1 EXON Missense_P1164L,Missense_P1263L,Missense_P1314L,Missense_P1164L,Missense_P1315L,Missense_P1249L,Silent,Missense_P1164L,Missense_P1164L rs2066835 9 98220322 [A/C] NM_001083604,NM_001354918,NM_001083603,NM_001083606,NM_000264,NM_001083602,NR_149061,NM_001083605,NM_001083607 PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1 EXON Synonymous_L896L,Synonymous_L995L,Synonymous_L1046L,Synonymous_L896L,Synonymous_L1047L,Synonymous_L981L,Silent,Synonymous_L896L,Synonymous_L896L rs28441412 9 98223856 [T/C] NM_001083604,NM_001354918,NM_001083603,NM_001083606,NM_000264,NM_001083602,NR_149061,NM_001083605,NM_001083607 PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16909898 9 98231008 [A/G] NM_001083604,NM_001354918,NM_001083603,NM_001083606,NM_000264,NM_001083602,NR_149061,NM_001083605,NM_001083607,NR_038982 PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,LOC100507346 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2066836 9 98238358 [A/G] NM_001083604,NM_001354918,NM_001083603,NM_001083606,NM_000264,NM_001083602,NR_149061,NM_001083605,NM_001083607 PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1 EXON Synonymous_A411A,Synonymous_A510A,Synonymous_A561A,Synonymous_A411A,Synonymous_A562A,Synonymous_A496A,Silent,Synonymous_A411A,Synonymous_A411A rs2277183 9 98238860 [T/C] NM_001083604,NM_001354918,NM_001083603,NM_001083606,NM_000264,NM_001083602,NR_149061,NM_001083605,NM_001083607 PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2297086 9 98240120 [A/G] NM_001083604,NM_001354918,NM_001083603,NM_001083606,NM_000264,NM_001083602,NR_149061,NM_001083605,NM_001083607 PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2066839 9 98241417 [T/C] NM_001083604,NM_001354918,NM_001083603,NM_001083606,NM_000264,NM_001083602,NR_149061,NM_001083605,NM_001083607 PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1 EXON Synonymous_L209L,Synonymous_L360L,Synonymous_L359L,Synonymous_L209L,Synonymous_L360L,Synonymous_L294L,Silent,Synonymous_L209L,Synonymous_L209L rs2066832 9 98241423 [A/G] NM_001083604,NM_001354918,NM_001083603,NM_001083606,NM_000264,NM_001083602,NR_149061,NM_001083605,NM_001083607 PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1 EXON Synonymous_H207H,Synonymous_H358H,Synonymous_H357H,Synonymous_H207H,Synonymous_H358H,Synonymous_H292H,Silent,Synonymous_H207H,Synonymous_H207H rs2297087 9 98242925 [A/G] NM_001083604,NM_001354918,NM_001083603,NM_001083606,NM_000264,NM_001083602,NR_149061,NM_001083605,NM_001083607 PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4448343 9 98266370 [A/G] NM_001083604,NM_001354918,NM_001083603,NM_001083606,NM_000264,NM_001083602,NR_149061,NM_001083605,NM_001083607,NM_001354919 PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4743526 9 98266654 [A/G] NM_001083604,NM_001354918,NM_001083603,NM_001083606,NM_000264,NM_001083602,NR_149061,NM_001083605,NM_001083607,NM_001354919 PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1,PTCH1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs28412122 9 98273791 [A/G] NM_001083603,NM_001083602,NM_001354919 PTCH1,PTCH1,PTCH1 Silent,Silent,Silent rs28536742 9 98283093 [T/C] rs16909955 9 98293208 [A/G] rs10512247 9 98296403 [T/C] rs2897050 9 98302535 [T/C] rs16909975 9 98307129 [A/G] rs1329393 9 98318926 [T/C] rs576594 9 98319211 [A/G] rs7875436 9 98326767 [A/C] rs7025117 9 98340320 [T/G] rs7040739 9 98348885 [T/G] rs1806706 9 98349921 [T/C] rs4590564 9 98355001 [T/C] rs10981328 9 98355145 [T/C] rs7850157 9 98355167 [A/G] rs882130 9 98358166 [T/C] rs10115098 9 98358683 [A/C] rs1889616 9 98359188 [A/G] rs6478058 9 98360213 [T/C] rs928618 9 98362492 [T/G] rs928619 9 98362742 [T/C] rs10120219 9 98364547 [T/C] rs10818991 9 98367717 [T/C] rs2405064 9 98368445 [T/C] rs1984119 9 98368761 [T/C] rs6478154 9 98371526 [A/C] rs4743090 9 98376367 [T/C] rs7036222 9 98380588 [A/G] rs7864457 9 98381360 [A/G] rs7854560 9 98382950 [T/C] rs7860540 9 98383097 [A/G] rs4742697 9 98387529 [T/C] rs930280 9 98391111 [T/C] rs6478302 9 98392340 [T/G] rs16910070 9 98393411 [T/C] rs16910073 9 98393954 [T/G] rs10989496 9 98397006 [A/G] rs10819953 9 98398956 [A/G] rs10989747 9 98402621 [A/G] rs7027192 9 98406181 [T/C] rs9695781 9 98407526 [A/C] rs10990303 9 98410405 [T/C] rs10990614 9 98414711 [A/G] rs1582073 9 98420881 [A/G] rs10991145 9 98424542 [A/G] rs7047000 9 98426006 [T/C] rs6478489 9 98428619 [A/G] rs4743148 9 98430574 [A/G] rs10991380 9 98430835 [T/C] rs12686467 9 98431637 [A/C] rs10820751 9 98432200 [A/G] rs817171 9 98434188 [T/G] rs700998 9 98435273 [A/C] rs17372214 9 98435489 [A/C] rs354276 9 98439240 [T/C] rs915228 9 98444303 [A/G] rs458477 9 98445060 [A/G] rs817182 9 98445610 [A/G] rs817184 9 98447172 [T/G] rs1335049 9 98447883 [A/G] rs16910142 9 98451398 [T/C] rs10816456 9 98451928 [A/G] rs10978784 9 98455545 [T/C] rs2782951 9 98466346 [T/C] rs16910150 9 98468885 [A/G] rs700992 9 98473646 [T/G] rs1977620 9 98475674 [T/C] rs700990 9 98476064 [T/C] rs460175 9 98478118 [T/G] rs1967908 9 98479529 [T/C] rs354271 9 98483660 [T/C] rs817166 9 98488882 [A/G] rs2119 9 98489142 [A/G] rs17373603 9 98493505 [T/C] rs700979 9 98496651 [A/G] rs700978 9 98496807 [A/G] rs700976 9 98497395 [T/C] rs700975 9 98497814 [A/G] rs16910200 9 98501892 [T/C] rs7035549 9 98502921 [T/C] rs414610 9 98504905 [A/G] rs700966 9 98507588 [A/G] rs4743271 9 98508628 [T/C] rs4742743 9 98515578 [A/G] rs933013 9 98516196 [A/G] rs10981787 9 98516889 [T/C] rs4743293 9 98525304 [A/C] rs7042092 9 98533383 [A/C] rs4743306 9 98534372 [T/C] rs10817721 9 98534462 [T/G] rs7035466 9 98535990 [T/C] rs7031550 9 98536017 [A/G] rs7854146 9 98538954 [A/G] rs7047415 9 98541232 [T/C] rs1836406 9 98542044 [A/C] rs10759835 9 98546523 [T/G] rs1836404 9 98550264 [T/C] rs1434729 9 98550467 [A/G] rs17393861 9 98554957 [T/C] rs10983622 9 98555942 [A/G] rs10983739 9 98559246 [T/C] rs816677 9 98568543 [T/C] NR_023390 LINC00476 EXON Silent rs17303045 9 98573509 [T/C] NR_023390 LINC00476 EXON Silent rs12349304 9 98574657 [A/G] NR_023390 LINC00476 EXON Silent rs816671 9 98575014 [A/C] NR_023390 LINC00476 EXON Silent rs816685 9 98583426 [A/G] NR_023390 LINC00476 Silent rs1413178 9 98586312 [T/C] NR_023390 LINC00476 Silent rs10985233 9 98596745 [A/G] NR_023390 LINC00476 Silent rs10985499 9 98603006 [T/G] NR_023390 LINC00476 Silent rs2149564 9 98607989 [T/G] NR_023390 LINC00476 Silent rs10481647 9 98623567 [A/G] NR_023390 LINC00476 Silent rs12004422 9 98635675 [T/C] NR_023390,NR_023389 LINC00476,LINC00476 Silent,Silent rs11792298 9 98636576 [A/G] NR_023390,NR_023389 LINC00476,LINC00476 Silent,Silent rs12001 9 98637430 [T/C] NR_023390,NR_023389 LINC00476,LINC00476 EXON Silent,Silent rs589458 9 98640671 [T/C] NM_001010895,NM_020207 ERCC6L2,ERCC6L2 Silent,Silent rs4742781 9 98645674 [A/G] NM_001010895,NM_020207 ERCC6L2,ERCC6L2 Silent,Silent rs7868270 9 98648085 [A/G] NM_001010895,NM_020207 ERCC6L2,ERCC6L2 Silent,Silent rs667018 9 98663517 [A/G] NM_001010895,NM_020207 ERCC6L2,ERCC6L2 Silent,Silent rs12345187 9 98668370 [T/C] NM_001010895,NM_020207 ERCC6L2,ERCC6L2 Silent,Silent rs12684321 9 98670456 [A/C] NM_001010895,NM_020207 ERCC6L2,ERCC6L2 Silent,Silent rs2274654 9 98691137 [T/C] NM_001010895,NM_020207 ERCC6L2,ERCC6L2 EXON Missense_V592A,Missense_V592A rs16910370 9 98695299 [T/C] NM_001010895,NM_020207 ERCC6L2,ERCC6L2 Silent,Silent rs7041571 9 98697786 [T/C] NM_001010895,NM_020207 ERCC6L2,ERCC6L2 Silent,Silent rs636311 9 98698810 [T/C] NM_001010895,NM_020207 ERCC6L2,ERCC6L2 Silent,Silent rs10988792 9 98719799 [A/C] NM_001010895,NM_020207 ERCC6L2,ERCC6L2 Silent,Silent rs10819668 9 98722130 [A/G] NM_001010895,NM_020207 ERCC6L2,ERCC6L2 Silent,Silent rs16910396 9 98733782 [A/C] NM_020207 ERCC6L2 Silent rs10739787 9 98739498 [A/G] NM_020207 ERCC6L2 Silent rs4743443 9 98745485 [A/G] NM_020207 ERCC6L2 Silent rs10512244 9 98748034 [A/G] NM_020207 ERCC6L2 Silent rs690484 9 98750606 [A/G] NM_020207 ERCC6L2 Silent rs657451 9 98765778 [T/C] NM_020207 ERCC6L2 Silent rs913407 9 98770928 [T/C] NM_020207 ERCC6L2 Silent rs17305728 9 98771261 [T/C] NM_020207 ERCC6L2 Silent rs10512243 9 98775459 [A/G] NM_020207 ERCC6L2 EXON Missense_A1554T rs3802439 9 98776111 [A/G] NM_020207 ERCC6L2 EXON Silent rs2672813 9 98781179 [A/G] rs238 9 98786276 [A/G] rs7023522 9 98794448 [T/C] rs10760718 9 98794679 [A/G] rs690575 9 98800048 [T/C] rs12684445 9 98805260 [A/G] rs10819754 9 98810506 [T/C] rs4592147 9 98817497 [A/G] rs734632 9 98818646 [A/G] rs10989088 9 98823407 [A/G] rs7021333 9 98823528 [T/G] rs4743501 9 98824475 [A/C] rs7041827 9 98826252 [T/C] rs10481699 9 98826559 [A/C] rs4743505 9 98827451 [T/C] rs4743506 9 98828510 [A/G] NR_033838 LOC158435 Silent rs10739797 9 98828889 [A/G] NR_033838 LOC158435 Silent rs4075991 9 98835067 [A/G] NR_033838 LOC158435 Silent rs10989160 9 98838260 [T/C] NR_033838 LOC158435 Silent rs4422885 9 98839535 [A/G] NR_033838 LOC158435 Silent rs4237201 9 98840177 [T/C] NR_033838 LOC158435 Silent rs4562454 9 98840796 [T/C] NR_033838 LOC158435 Silent rs3925103 9 98843334 [A/C] NR_033838 LOC158435 Silent rs4291387 9 98843638 [A/G] NR_033838 LOC158435 Silent rs4743521 9 98844752 [A/G] NR_033838 LOC158435 Silent rs4743525 9 98849009 [T/C] NR_033838 LOC158435 Silent rs4443781 9 98851230 [A/G] NR_033838 LOC158435 Silent rs10760747 9 98851504 [T/C] NR_033838 LOC158435 Silent rs4620409 9 98851777 [T/C] NR_033838 LOC158435 Silent rs13296065 9 98853564 [A/G] NR_033838 LOC158435 Silent rs12338607 9 98856343 [T/C] NR_033838 LOC158435 Silent rs7862829 9 98856744 [T/C] NR_033838 LOC158435 Silent rs10760758 9 98858735 [A/G] NR_033838 LOC158435 Silent rs16910480 9 98864367 [T/C] rs10819861 9 98867813 [T/C] rs10819882 9 98874639 [A/G] NR_132344 LOC158434 Silent rs10733713 9 98877206 [T/C] NR_132344 LOC158434 Silent rs12115436 9 98879734 [A/G] rs10989347 9 98879886 [T/C] rs7865266 9 98884044 [A/G] rs4743556 9 98884945 [T/C] rs4743558 9 98885144 [A/G] rs10760787 9 98888628 [T/C] rs7041700 9 98891743 [A/G] rs7871616 9 98895004 [T/G] rs12341515 9 98904169 [A/G] rs2010398 9 98905141 [T/C] rs3892812 9 98907515 [A/G] rs4743597 9 98918219 [T/C] rs4743598 9 98918433 [A/G] rs10989494 9 98923066 [A/C] rs10819930 9 98923268 [A/G] rs10989497 9 98924140 [T/G] rs10989503 9 98925146 [T/C] rs4742865 9 98925677 [A/G] rs4743605 9 98926345 [T/C] rs10819936 9 98926420 [A/G] rs12353207 9 98928974 [A/G] rs10819946 9 98929986 [A/G] rs4743611 9 98932408 [T/C] rs7862977 9 98932749 [A/G] rs10819950 9 98935333 [A/G] rs7873726 9 98935378 [T/C] rs7857532 9 98936604 [A/G] rs7857544 9 98936624 [A/G] rs3892706 9 98938479 [T/C] rs16910583 9 98939192 [T/C] rs714676 9 98940178 [A/G] rs10819981 9 98952847 [A/G] rs7048593 9 98957977 [T/C] rs912465 9 98958949 [A/G] rs4743638 9 98962102 [A/C] rs7857474 9 98962994 [A/C] rs10117895 9 98963734 [T/C] rs4743644 9 98967342 [T/C] rs13300278 9 98968142 [T/C] rs13300603 9 98968292 [T/C] rs7869882 9 98969746 [A/G] rs10115086 9 98970911 [T/G] rs11791270 9 98972430 [A/G] rs7020106 9 98974141 [T/C] rs10820020 9 98978660 [A/G] rs412147 9 98985321 [A/G] rs2479827 9 98988429 [A/G] rs2031321 9 98991303 [T/C] rs280661 9 98991519 [A/G] rs8190581 9 98995852 [A/G] rs7048229 9 98996534 [A/G] rs407179 9 99012277 [T/C] NM_000197,NR_146524 HSD17B3,HSD17B3-AS1 EXON Silent,Silent rs2026001 9 99016095 [T/G] NM_000197 HSD17B3 Silent rs370438 9 99016896 [A/C] NM_000197 HSD17B3 Silent rs2257157 9 99018442 [A/G] NM_000197 HSD17B3 Silent rs7039978 9 99021582 [A/G] NM_000197 HSD17B3 Silent rs2476923 9 99021661 [A/G] NM_000197 HSD17B3 Silent rs280654 9 99029431 [A/G] NM_000197 HSD17B3 Silent rs11788785 9 99031628 [A/G] NM_000197 HSD17B3 Silent rs2476927 9 99038030 [A/G] NM_000197 HSD17B3 Silent rs1983828 9 99040501 [T/G] NM_000197 HSD17B3 Silent rs8190512 9 99050100 [A/C] NM_000197 HSD17B3 Silent rs2479828 9 99050794 [A/G] NM_000197 HSD17B3 Silent rs10990258 9 99052540 [T/C] NM_000197 HSD17B3 Silent rs1119864 9 99054604 [T/C] NM_000197 HSD17B3 Silent rs11788083 9 99056209 [A/G] NM_000197 HSD17B3 Silent rs7029101 9 99060612 [T/C] NM_000197 HSD17B3 Silent rs8190496 9 99061618 [A/G] NM_000197 HSD17B3 Silent rs2066480 9 99064296 [T/C] NM_000197 HSD17B3 EXON Missense_V31I rs2066476 9 99064415 [T/C] NM_000197 HSD17B3 EXON Silent rs11788621 9 99069230 [T/C] rs4743713 9 99069944 [A/C] rs4742910 9 99073152 [A/G] rs4743716 9 99075707 [T/C] rs7022202 9 99077386 [T/C] NR_104627 SLC35D2 Silent rs10990403 9 99078150 [T/C] NR_104627 SLC35D2 Silent rs12685240 9 99079114 [T/C] NR_104627 SLC35D2 Silent rs4743722 9 99081512 [A/G] NR_104627 SLC35D2 Silent rs10126039 9 99085363 [A/C] NR_104627,NM_001286990,NM_007001 SLC35D2,SLC35D2,SLC35D2 Silent,Silent,Silent rs7858292 9 99087446 [A/G] NR_104627,NM_001286990,NM_007001 SLC35D2,SLC35D2,SLC35D2 Silent,Silent,Silent rs10990503 9 99087685 [T/C] NR_104627,NM_001286990,NM_007001 SLC35D2,SLC35D2,SLC35D2 Silent,Silent,Silent rs6479272 9 99097527 [T/C] NR_104627,NM_001286990,NM_007001 SLC35D2,SLC35D2,SLC35D2 Silent,Silent,Silent rs10820410 9 99108678 [A/C] NR_104627,NM_001286990,NM_007001 SLC35D2,SLC35D2,SLC35D2 Silent,Silent,Silent rs13284545 9 99118230 [T/C] NR_104627,NM_001286990,NM_007001 SLC35D2,SLC35D2,SLC35D2 Silent,Silent,Silent rs10820507 9 99148152 [A/G] rs13300924 9 99152660 [T/C] NM_153695 ZNF367 Silent rs10990927 9 99154040 [A/G] NM_153695 ZNF367 Silent rs12002084 9 99165576 [T/C] NM_153695 ZNF367 Silent rs10820564 9 99171631 [A/G] NM_153695 ZNF367 Silent rs10760999 9 99174951 [A/G] NM_153695 ZNF367 Silent rs1885427 9 99188248 [A/G] rs10820597 9 99188347 [A/C] rs10820598 9 99189255 [A/G] rs7870106 9 99210584 [A/G] rs10991346 9 99247758 [T/C] NM_014282 HABP4 Silent rs7030316 9 99250463 [T/C] NM_014282 HABP4 EXON Synonymous_L364L rs1057687 9 99252464 [A/G] NM_014282 HABP4 EXON Silent rs13302712 9 99260928 [A/G] rs7871404 9 99262296 [A/G] rs3802442 9 99263535 [T/C] NM_033331,NM_001077181,NM_001351569,NM_001351570,NM_003671,NR_147239 CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B EXON Silent,Silent,Silent,Silent,Silent,Silent rs10118793 9 99268429 [T/C] NM_033331,NM_001077181,NM_001351569,NM_001351570,NM_003671,NR_147239 CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B Silent,Silent,Silent,Silent,Silent,Silent rs10125037 9 99285852 [T/C] NM_033331,NM_001077181,NM_001351569,NM_001351570,NM_003671,NR_147239,NM_001351568,NM_001351567 CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16911097 9 99288951 [A/G] NM_033331,NM_001077181,NM_001351569,NM_001351570,NM_003671,NR_147239,NM_001351568,NM_001351567 CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7866422 9 99294285 [A/G] NM_033331,NM_001077181,NM_001351569,NM_001351570,NM_003671,NR_147239,NM_001351568,NM_001351567 CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9969705 9 99308502 [A/G] NM_033331,NM_001077181,NM_001351569,NM_001351570,NM_003671,NR_147239,NM_001351568,NM_001351567 CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7869415 9 99311177 [A/G] NM_033331,NM_001077181,NM_001351569,NM_001351570,NM_003671,NR_147239,NM_001351568,NM_001351567 CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16911186 9 99312032 [T/C] NM_033331,NM_001077181,NM_001351569,NM_001351570,NM_003671,NR_147239,NM_001351568,NM_001351567 CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1411885 9 99324377 [T/C] NM_033331,NM_001077181,NM_001351569,NM_001351570,NM_003671,NR_147239,NM_001351568,NM_001351567 CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B,CDC14B Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7042473 9 99346570 [T/C] NM_033331,NM_003671,NR_147239,NM_001351567 CDC14B,CDC14B,CDC14B,CDC14B Silent,Silent,Silent,Silent rs10978403 9 99387997 [A/G] rs10978436 9 99400209 [T/C] rs6477597 9 99406750 [T/C] NM_153698 PRXL2C Silent rs10978444 9 99407073 [T/C] NM_153698 PRXL2C Silent rs10978447 9 99408152 [T/C] NM_153698 PRXL2C Silent rs10978455 9 99411960 [T/C] NM_153698 PRXL2C Silent rs12340043 9 99427491 [A/G] rs7045407 9 99435093 [T/G] rs2165890 9 99448564 [T/C] rs6477621 9 99452245 [T/G] rs10978609 9 99452968 [T/G] rs2083825 9 99461810 [T/C] rs7046097 9 99472234 [T/C] rs1596359 9 99487607 [T/C] rs16911482 9 99488406 [T/C] NR_026792 LOC441455 EXON Silent rs7871612 9 99489682 [T/C] NR_026792 LOC441455 EXON Silent rs10978719 9 99492593 [A/G] rs10114863 9 99509624 [T/C] rs10114918 9 99509885 [T/C] rs10124797 9 99519505 [A/G] NM_001314059,NM_001314060,NM_014930 ZNF510,ZNF510,ZNF510 EXON Silent,Silent,Silent rs16911522 9 99521123 [T/C] NM_001314059,NM_001314060,NM_014930 ZNF510,ZNF510,ZNF510 EXON Synonymous_K663K,Synonymous_K601K,Synonymous_K663K rs3780548 9 99525487 [A/G] NM_001314059,NM_001314060,NM_014930 ZNF510,ZNF510,ZNF510 EXON Missense_C89R,Missense_C27R,Missense_C89R rs2289651 9 99537071 [T/C] NM_001314059,NM_001314060,NM_014930 ZNF510,ZNF510,ZNF510 EXON Missense_Q43R,Silent,Missense_Q43R rs2289650 9 99538169 [T/C] NM_001314059,NM_001314060,NM_014930 ZNF510,ZNF510,ZNF510 Silent,Silent,Silent rs10124911 9 99567384 [A/C] rs10816602 9 99577427 [A/G] rs10979152 9 99579100 [A/G] NM_001346993,NM_001001662,NM_001346995,NM_001346991 ZNF782,ZNF782,ZNF782,ZNF782 EXON Silent,Silent,Silent,Silent rs4645656 9 99581811 [T/C] NM_001346993,NM_001001662,NM_001346995,NM_001346991 ZNF782,ZNF782,ZNF782,ZNF782 EXON Missense_R141H,Missense_R165H,Missense_R33H,Missense_R165H rs7859940 9 99584880 [A/G] NM_001346993,NM_001001662,NM_001346995,NM_001346991 ZNF782,ZNF782,ZNF782,ZNF782 Silent,Silent,Silent,Silent rs6477710 9 99585314 [T/G] NM_001346993,NM_001001662,NM_001346995,NM_001346991 ZNF782,ZNF782,ZNF782,ZNF782 Silent,Silent,Silent,Silent rs7848710 9 99589296 [T/C] NM_001346993,NM_001001662,NM_001346995,NM_001346991 ZNF782,ZNF782,ZNF782,ZNF782 Silent,Silent,Silent,Silent rs2406184 9 99605174 [T/C] NM_001346993,NM_001001662,NM_001346995,NM_001346991 ZNF782,ZNF782,ZNF782,ZNF782 Silent,Silent,Silent,Silent rs10115814 9 99606224 [T/C] NM_001346993,NM_001001662,NM_001346995,NM_001346991 ZNF782,ZNF782,ZNF782,ZNF782 Silent,Silent,Silent,Silent rs7037100 9 99606529 [T/C] NM_001346993,NM_001001662,NM_001346995,NM_001346991 ZNF782,ZNF782,ZNF782,ZNF782 Silent,Silent,Silent,Silent rs2296812 9 99619081 [T/C] rs7040493 9 99620277 [A/G] rs6477733 9 99625063 [T/G] rs10119207 9 99651444 [T/C] rs1046795 9 99655358 [T/C] rs10980069 9 99762891 [T/C] NM_001355230,NM_001355229,NM_001355228 MFSD14C,MFSD14C,MFSD14C Silent,Silent,Silent rs10123754 9 99792208 [T/C] NM_001201575,NM_001333 CTSV,CTSV EXON Silent,Silent rs16919034 9 99793583 [A/G] NM_001201575,NM_001333 CTSV,CTSV EXON Silent,Silent rs15394 9 99795125 [A/C] NM_001201575,NM_001333 CTSV,CTSV EXON Silent,Silent rs10118886 9 99798293 [T/G] NM_001201575,NM_001333 CTSV,CTSV Silent,Silent rs12236690 9 99806169 [T/C] rs10816962 9 99811206 [T/C] rs4510972 9 99814841 [T/G] rs10759417 9 99815929 [T/C] rs4743056 9 99821611 [T/C] rs11999620 9 99823590 [A/G] rs4361859 9 99824697 [A/G] rs6477872 9 99832156 [T/C] rs16924142 9 99838751 [A/G] NR_002942 GAS2L1P2 EXON Silent rs10980463 9 99838887 [A/G] NR_002942 GAS2L1P2 EXON Silent rs10119016 9 99849281 [A/G] rs3802470 9 99856397 [A/G] rs7044791 9 99873161 [T/C] rs10980643 9 99874486 [T/C] rs13283681 9 99883513 [A/G] rs4399037 9 99890895 [T/C] rs2001382 9 99895662 [T/C] rs4743059 9 99899313 [T/C] rs10980992 9 99946041 [T/C] NR_136286 ANKRD18CP Silent rs10981062 9 99957548 [T/C] NR_136286 ANKRD18CP Silent rs4743061 9 99973826 [T/C] NR_136286 ANKRD18CP Silent rs16918311 9 99973992 [A/G] NR_136286 ANKRD18CP Silent rs11791310 9 100005128 [A/G] NR_036526,NR_036529,NR_036527,NR_036528 SUGT1P4-STRA6LP,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180 Silent,Silent,Silent,Silent rs7863530 9 100016763 [T/C] NR_036526,NR_036529,NR_036527,NR_036528 SUGT1P4-STRA6LP,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180 Silent,Silent,Silent,Silent rs16918674 9 100025251 [A/G] NR_036526,NR_036529,NR_036527,NR_036528 SUGT1P4-STRA6LP,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180 Silent,Silent,Silent,Silent rs3994560 9 100038067 [T/C] NR_036526,NR_036529,NR_036527,NR_036528 SUGT1P4-STRA6LP,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180 Silent,Silent,Silent,Silent rs7855042 9 100043031 [A/G] NR_036526,NR_036529,NR_036527,NR_036528 SUGT1P4-STRA6LP,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180 Silent,Silent,Silent,Silent rs3747512 9 100043849 [A/G] NR_036526,NR_036529,NR_036527,NR_036528 SUGT1P4-STRA6LP,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180 EXON Silent,Silent,Silent,Silent rs2487874 9 100049972 [A/C] NR_036526,NR_036529,NR_036527,NR_036528 SUGT1P4-STRA6LP,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180 EXON Silent,Silent,Silent,Silent rs2818242 9 100051415 [A/C] NR_036526,NR_036529,NR_036527,NR_036528 SUGT1P4-STRA6LP,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180 Silent,Silent,Silent,Silent rs10817378 9 100054429 [T/C] NR_036526,NR_036529,NR_036527,NR_036528 SUGT1P4-STRA6LP,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180 Silent,Silent,Silent,Silent rs2290934 9 100059090 [T/C] NR_036526,NR_036529,NR_036527,NR_036528 SUGT1P4-STRA6LP,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180 EXON Silent,Silent,Silent,Silent rs1903635 9 100061226 [A/G] NR_036529,NR_036527,NR_036528 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180 Silent,Silent,Silent rs10817403 9 100072076 [A/G] NR_036529,NR_036527,NR_036528,NM_001348010,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180,CCDC180 Silent,Silent,Silent,Silent,Silent rs3747504 9 100074446 [T/C] NR_036529,NR_036527,NR_036528,NM_001348010,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180,CCDC180 EXON Silent,Silent,Silent,Synonymous_I148I,Synonymous_I148I rs7864805 9 100075521 [A/C] NR_036529,NR_036527,NR_036528,NM_001348010,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180,CCDC180 EXON Silent,Silent,Silent,Missense_P162H,Missense_P162H rs3747502 9 100076896 [A/G] NR_036529,NR_036527,NR_036528,NM_001348010,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180,CCDC180 Silent,Silent,Silent,Silent,Silent rs3747498 9 100087220 [A/G] NR_036529,NR_036527,NR_036528,NM_001348010,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180,CCDC180 Silent,Silent,Silent,Silent,Silent rs10981625 9 100088971 [A/G] NR_036529,NR_036527,NR_036528,NM_001348010,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180,CCDC180 Silent,Silent,Silent,Silent,Silent rs6478095 9 100097095 [A/G] NR_036529,NR_036527,NR_036528,NM_001348010,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180,CCDC180 Silent,Silent,Silent,Silent,Silent rs10981664 9 100097344 [T/C] NR_036529,NR_036527,NR_036528,NM_001348010,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180,CCDC180 Silent,Silent,Silent,Silent,Silent rs1947717 9 100105735 [T/C] NR_036529,NR_036527,NR_036528,NM_001348010,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180,CCDC180 EXON Silent,Silent,Silent,Synonymous_C837C,Synonymous_C840C rs10435865 9 100107236 [T/C] NR_036529,NR_036527,NR_036528,NM_001348010,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180,CCDC180 Silent,Silent,Silent,Silent,Silent rs4313271 9 100114057 [A/G] NR_036529,NR_036527,NR_036528,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180 Silent,Silent,Silent,Silent rs4743082 9 100116059 [T/G] NR_036529,NR_036527,NR_036528,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180 Silent,Silent,Silent,Silent rs3747495 9 100122291 [T/C] NR_036529,NR_036527,NR_036528,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180 EXON Silent,Silent,Silent,Missense_F1175L rs2306093 9 100133973 [A/G] NR_036529,NR_036527,NR_036528,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180 EXON Silent,Silent,Silent,Missense_D1573N rs2242187 9 100137394 [T/C] NR_036529,NR_036527,NR_036528,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180 Silent,Silent,Silent,Silent rs11581 9 100139161 [A/G] NR_036529,NR_036527,NR_036528,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180 EXON Silent,Silent,Silent,Synonymous_Q1697Q rs898870 9 100139396 [A/G] NR_036529,NR_036527,NR_036528,NM_020893 SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,SUGT1P4-STRA6LP-CCDC180,CCDC180 EXON Silent,Silent,Silent,Silent rs16919509 9 100140042 [A/C] NM_020893 CCDC180 EXON Silent rs12115447 9 100152684 [A/G] rs10817513 9 100153594 [A/C] NR_026847 LOC286359 EXON Silent rs1020884 9 100158052 [T/C] NR_026847 LOC286359 Silent rs10759658 9 100161524 [A/G] rs11791849 9 100163998 [T/C] rs1381533 9 100167429 [T/C] rs1462091 9 100169852 [A/G] rs12551443 9 100172620 [T/C] rs7853581 9 100188129 [T/C] NM_001302884,NM_014290 TDRD7,TDRD7 Silent,Silent rs16920147 9 100190973 [A/G] NM_001302884,NM_014290 TDRD7,TDRD7 Silent,Silent rs13286028 9 100192986 [T/C] NM_001302884,NM_014290 TDRD7,TDRD7 Silent,Silent rs2045732 9 100194406 [T/C] NM_001302884,NM_014290 TDRD7,TDRD7 EXON Missense_V76A,Missense_V150A rs11999505 9 100194825 [A/G] NM_001302884,NM_014290 TDRD7,TDRD7 Silent,Silent rs17423994 9 100203708 [T/G] NM_001302884,NM_014290 TDRD7,TDRD7 Silent,Silent rs4557815 9 100211869 [T/C] NM_001302884,NM_014290 TDRD7,TDRD7 Silent,Silent rs7871839 9 100220058 [A/G] NM_001302884,NM_014290 TDRD7,TDRD7 Silent,Silent rs7020902 9 100226631 [A/G] NM_001302884,NM_014290 TDRD7,TDRD7 Silent,Silent rs4742693 9 100233189 [T/C] NM_001302884,NM_014290 TDRD7,TDRD7 Silent,Silent rs10817671 9 100253819 [A/G] NM_001302884,NM_014290 TDRD7,TDRD7 Silent,Silent rs2149981 9 100269291 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs10982444 9 100270198 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs11788529 9 100270886 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs7862883 9 100279009 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs4576532 9 100280011 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs953417 9 100282313 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs10759754 9 100285297 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs10982508 9 100285653 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs7019830 9 100287073 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs2149987 9 100296219 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs913913 9 100297592 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs1007070 9 100297695 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs10982602 9 100299775 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs16921671 9 100300464 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs1571567 9 100305357 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs10817736 9 100305698 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs10817737 9 100306267 [T/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs7045553 9 100307789 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs10817739 9 100308231 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs7867486 9 100310534 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs10982661 9 100310666 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs7855669 9 100310711 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs4742698 9 100312284 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs7875496 9 100313725 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs4743106 9 100313793 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs4743107 9 100313903 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs1475545 9 100316230 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs913911 9 100318458 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs10817759 9 100319031 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs7871185 9 100319894 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs10759781 9 100324654 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs4743110 9 100326824 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs4743114 9 100327714 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs10817781 9 100330140 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs1475543 9 100333671 [A/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs1536950 9 100333772 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs2149986 9 100334586 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs913912 9 100341038 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs2805792 9 100353801 [T/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs16922319 9 100354064 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs2805785 9 100357256 [A/G] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs2773343 9 100357658 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs958346 9 100361864 [T/C] NM_001166116,NM_003275 TMOD1,TMOD1 Silent,Silent rs3802472 9 100364451 [A/C] NM_139246 TSTD2 EXON Silent rs1034100 9 100365431 [T/G] NM_139246 TSTD2 Silent rs1034099 9 100365473 [T/G] NM_139246 TSTD2 Silent rs7857174 9 100366843 [T/C] NM_139246 TSTD2 Silent rs952765 9 100367306 [T/C] NM_139246 TSTD2 Silent rs2805777 9 100381034 [T/C] NM_139246 TSTD2 Silent rs10817858 9 100388119 [T/G] NM_139246 TSTD2 EXON Missense_A109D rs2773347 9 100388197 [T/C] NM_139246 TSTD2 EXON Missense_R83Q rs12001859 9 100392928 [A/G] NM_139246 TSTD2 Silent rs2773350 9 100399132 [A/G] NM_001351506,NM_001351507,NM_002486,NM_001351505,NM_001351504 NCBP1,NCBP1,NCBP1,NCBP1,NCBP1 Silent,Silent,Silent,Silent,Silent rs715749 9 100420142 [A/G] NM_001351506,NM_001351507,NM_002486,NM_001351505,NM_001351504 NCBP1,NCBP1,NCBP1,NCBP1,NCBP1 Silent,Silent,Silent,Silent,Silent rs10116536 9 100428977 [A/G] NM_001351506,NM_001351507,NM_002486,NM_001351505,NM_001351504 NCBP1,NCBP1,NCBP1,NCBP1,NCBP1 Silent,Silent,Silent,Silent,Silent rs3176757 9 100437058 [A/G] rs3176753 9 100437443 [A/G] NR_149093,NM_000380,NR_027302,NR_149091,NR_149092,NR_149094,NM_001354975 XPA,XPA,XPA,XPA,XPA,XPA,XPA EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3176740 9 100439554 [T/C] NR_149093,NM_000380,NR_027302,NR_149091,NR_149092,NR_149094,NM_001354975 XPA,XPA,XPA,XPA,XPA,XPA,XPA Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2808667 9 100442806 [T/C] NR_149093,NM_000380,NR_027302,NR_149091,NR_149092,NR_149094,NM_001354975 XPA,XPA,XPA,XPA,XPA,XPA,XPA Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10983315 9 100451916 [T/C] NR_149093,NM_000380,NR_027302,NR_149091,NR_149092,NR_149094,NM_001354975 XPA,XPA,XPA,XPA,XPA,XPA,XPA EXON Silent,Missense_V97I,Silent,Silent,Silent,Silent,Missense_V55I rs1800975 9 100459578 [T/C] NR_149093,NM_000380,NR_027302,NR_149091,NR_149092,NR_149094,NM_001354975 XPA,XPA,XPA,XPA,XPA,XPA,XPA EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3176625 9 100460708 [T/C] rs10817938 9 100462409 [T/C] NR_147055 PTCSC2 Silent rs2808672 9 100467594 [T/C] NR_147055 PTCSC2 Silent rs2808673 9 100468218 [T/G] NR_147055 PTCSC2 Silent rs7849509 9 100480125 [T/C] NR_147055 PTCSC2 EXON Silent rs2668797 9 100482503 [A/G] NR_147055 PTCSC2 Silent rs953199 9 100482976 [A/C] NR_147055 PTCSC2 Silent rs2036958 9 100496977 [T/C] NR_147055 PTCSC2 Silent rs2668802 9 100498831 [T/C] NR_147055 PTCSC2 Silent rs2808699 9 100505830 [A/C] NR_147055 PTCSC2 Silent rs2805838 9 100507159 [T/G] NR_147055 PTCSC2 Silent rs16924016 9 100511331 [T/C] NR_147055 PTCSC2 Silent rs10818021 9 100512420 [T/C] NR_147055 PTCSC2 Silent rs10818023 9 100514919 [A/G] NR_147055 PTCSC2 Silent rs1398230 9 100520013 [T/C] NR_147055 PTCSC2 Silent rs7034310 9 100527157 [A/G] NR_147055 PTCSC2 Silent rs7357631 9 100528320 [A/G] NR_147055 PTCSC2 Silent rs1877432 9 100543880 [A/G] NR_147055 PTCSC2 Silent rs7850258 9 100549013 [A/G] NR_147055 PTCSC2 Silent rs16924202 9 100549611 [A/G] NR_147055 PTCSC2 Silent rs1443438 9 100550028 [T/C] NR_147055 PTCSC2 Silent rs12347079 9 100550227 [T/C] NR_147055 PTCSC2 Silent rs10818071 9 100550253 [A/G] NR_147055 PTCSC2 Silent rs965513 9 100556109 [A/G] NR_147055 PTCSC2 Silent rs10759944 9 100556972 [A/G] NR_147055 PTCSC2 Silent rs16924274 9 100557291 [T/C] NR_147055 PTCSC2 Silent rs7871887 9 100571442 [T/C] NR_147055 PTCSC2 Silent rs7870795 9 100574120 [T/C] NR_147055 PTCSC2 Silent rs10983871 9 100585818 [A/G] NR_147055 PTCSC2 Silent rs7848973 9 100588839 [A/G] NR_147055 PTCSC2 Silent rs10983893 9 100596165 [T/C] NR_147055 PTCSC2 Silent rs12348691 9 100608682 [A/G] NR_147055 PTCSC2 Silent rs10759960 9 100608745 [A/G] NR_147055 PTCSC2 Silent rs7043516 9 100617433 [A/C] NM_004473 FOXE1 EXON Silent rs1443435 9 100617583 [T/C] NM_004473 FOXE1 EXON Silent rs10984009 9 100618660 [A/G] NM_004473 FOXE1 EXON Silent rs925487 9 100636398 [T/C] rs10119795 9 100637339 [T/C] rs7866436 9 100650096 [A/G] rs16925130 9 100660122 [T/C] rs7040232 9 100664194 [A/G] rs6586 9 100666931 [T/C] NM_016481,NM_001330725 TRMO,TRMO EXON Silent,Silent rs1561961 9 100667599 [T/C] NM_016481,NM_001330725 TRMO,TRMO Silent,Silent rs1561958 9 100669799 [T/G] NM_016481,NM_001330725 TRMO,TRMO Silent,Silent rs2282192 9 100672338 [T/C] NM_016481,NM_001330725 TRMO,TRMO EXON Missense_V324M,Missense_V178M rs1127703 9 100675816 [A/G] NM_016481,NM_001330725 TRMO,TRMO EXON Synonymous_N92N,Silent rs10984361 9 100681490 [T/C] NM_016481,NM_001330725 TRMO,TRMO Silent,Silent rs3802475 9 100684719 [A/C] NM_016481,NM_001330725 TRMO,TRMO EXON Synonymous_V19V,Silent rs3183927 9 100684757 [A/G] NM_016481,NM_001330725 TRMO,TRMO EXON Missense_S7P,Silent rs10512256 9 100686815 [T/G] rs7030887 9 100688511 [T/C] rs1059003 9 100689693 [A/G] NM_197978,NM_018437 HEMGN,HEMGN EXON Synonymous_N476N,Synonymous_N476N rs1475696 9 100691397 [T/C] NM_197978,NM_018437 HEMGN,HEMGN Silent,Silent rs17687621 9 100721555 [T/C] rs4743149 9 100726574 [A/G] rs10116976 9 100739888 [T/C] rs1572025 9 100741115 [T/G] rs7855088 9 100742253 [T/C] rs10984649 9 100750014 [T/C] NM_006401 ANP32B Silent rs10984650 9 100750623 [T/G] NM_006401 ANP32B Silent rs7855432 9 100760113 [T/G] NM_006401 ANP32B Silent rs7041878 9 100763358 [T/C] NM_006401 ANP32B Silent rs1010777 9 100767860 [A/G] NM_006401 ANP32B Silent rs10984811 9 100784050 [A/C] rs6478537 9 100818344 [T/C] rs6478539 9 100818720 [T/C] rs3199064 9 100819070 [T/G] NM_018946 NANS EXON Silent rs13049 9 100823084 [T/C] NM_018946 NANS EXON Synonymous_A51A rs17806613 9 100828356 [T/C] NM_018946 NANS Silent rs4412474 9 100828866 [A/G] NM_018946 NANS Silent rs9918951 9 100830392 [A/G] NM_018946 NANS Silent rs7021059 9 100833709 [A/C] NM_018946 NANS Silent rs7021804 9 100834294 [T/C] NM_018946 NANS Silent rs16912590 9 100835163 [A/G] NM_018946 NANS Silent rs10818468 9 100836889 [T/C] NM_018946 NANS Silent rs6478556 9 100842005 [T/C] NM_018946 NANS Silent rs4237190 9 100843417 [A/G] NM_018946 NANS Silent rs16912622 9 100843660 [A/C] NM_018946 NANS Silent rs34342219 9 100845302 [T/C] NM_018946 NANS EXON Synonymous_L349L rs2296079 9 100857194 [T/C] NM_014788,NM_033219 TRIM14,TRIM14 EXON Missense_V219M,Missense_V219M rs1886002 9 100866639 [T/C] NM_014788,NM_033219 TRIM14,TRIM14 Silent,Silent rs7855251 9 100868189 [T/C] NM_014788,NM_033219 TRIM14,TRIM14 Silent,Silent rs10760120 9 100868900 [A/G] NM_014788,NM_033219 TRIM14,TRIM14 Silent,Silent rs9792455 9 100869920 [A/G] NM_014788,NM_033219 TRIM14,TRIM14 Silent,Silent rs2417731 9 100871717 [T/C] NM_014788,NM_033219 TRIM14,TRIM14 Silent,Silent rs12351692 9 100882441 [A/G] rs12238311 9 100884896 [A/G] NM_003389,NM_052820 CORO2A,CORO2A EXON Silent,Silent rs1891323 9 100884938 [A/G] NM_003389,NM_052820 CORO2A,CORO2A EXON Silent,Silent rs1746239 9 100885779 [T/C] NM_003389,NM_052820 CORO2A,CORO2A EXON Silent,Silent rs942165 9 100889340 [T/G] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs11794723 9 100890591 [A/G] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs735111 9 100895443 [T/C] NM_003389,NM_052820 CORO2A,CORO2A EXON Synonymous_T175T,Synonymous_T175T rs10985166 9 100896048 [T/C] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs2795487 9 100904179 [T/C] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs3780465 9 100905658 [A/G] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs2795489 9 100909931 [A/G] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs2795490 9 100909996 [T/G] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs2795491 9 100911422 [T/C] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs814027 9 100911671 [T/C] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs2795492 9 100913376 [A/G] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs2250494 9 100919318 [A/C] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs3780457 9 100922407 [A/G] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs1544205 9 100922874 [A/G] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs7862309 9 100925136 [T/C] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs10985257 9 100927255 [A/C] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs10491723 9 100927632 [A/G] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs10491724 9 100927851 [A/G] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs13300050 9 100927886 [T/C] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs2417733 9 100928982 [A/G] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs4743174 9 100930253 [T/C] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs10985279 9 100930947 [A/G] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs4610873 9 100934033 [T/G] NM_003389,NM_052820 CORO2A,CORO2A Silent,Silent rs2275710 9 100935050 [T/C] NM_003389,NM_052820 CORO2A,CORO2A EXON Silent,Silent rs2231654 9 100935526 [T/C] NM_052820 CORO2A Silent rs16913573 9 100941315 [T/C] NM_052820 CORO2A Silent rs16913581 9 100942499 [T/C] NM_052820 CORO2A Silent rs12552786 9 100943397 [A/C] NM_052820 CORO2A Silent rs10818575 9 100945146 [T/C] NM_052820 CORO2A Silent rs16913644 9 100947796 [T/C] NM_052820 CORO2A Silent rs7870439 9 100951838 [T/G] NM_052820 CORO2A Silent rs4743184 9 100955714 [A/G] rs10985391 9 100960607 [A/G] rs3739668 9 100963653 [T/C] NM_001267571,NR_051978,NM_001267572,NM_018421 TBC1D2,TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent,Silent rs3780453 9 100964651 [T/C] NM_001267571,NR_051978,NM_001267572,NM_018421 TBC1D2,TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent,Silent rs3739667 9 100965472 [T/C] NM_001267571,NR_051978,NM_001267572,NM_018421 TBC1D2,TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent,Silent rs3780447 9 100970289 [A/G] NM_001267571,NR_051978,NM_001267572,NM_018421 TBC1D2,TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent,Silent rs7045430 9 100970307 [A/G] NM_001267571,NR_051978,NM_001267572,NM_018421 TBC1D2,TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent,Silent rs7854249 9 100975694 [A/G] NM_001267571,NR_051978,NM_001267572,NM_018421 TBC1D2,TBC1D2,TBC1D2,TBC1D2 EXON Silent,Silent,Silent,Silent rs4743186 9 100976086 [A/G] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent rs12348328 9 100977139 [T/C] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent rs7041802 9 100981757 [T/G] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent rs2282432 9 100982858 [T/C] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent rs12351801 9 100984946 [T/C] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent rs10818621 9 100985312 [A/G] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent rs10985507 9 100985388 [A/G] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent rs7868451 9 100987622 [A/G] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent rs16914086 9 100988477 [A/G] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent rs1573025 9 100991430 [A/C] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 EXON Missense_G261V,Silent,Missense_G261V rs879368 9 100995758 [T/G] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 EXON Missense_P241T,Silent,Missense_P241T rs10985573 9 101002868 [T/C] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent rs4743193 9 101008541 [T/C] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent rs7853442 9 101008885 [A/G] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent rs12349672 9 101010704 [T/G] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent rs16914245 9 101014824 [T/C] NM_001267571,NR_051978,NM_018421 TBC1D2,TBC1D2,TBC1D2 Silent,Silent,Silent rs10115971 9 101024887 [A/G] rs10818693 9 101026356 [A/C] rs10985680 9 101034477 [A/G] rs10760233 9 101034626 [A/G] rs10739615 9 101040915 [A/G] rs1435259 9 101046441 [T/C] rs1435256 9 101048935 [T/C] rs10818743 9 101056009 [T/G] NM_005458 GABBR2 Silent rs10985765 9 101056122 [T/C] NM_005458 GABBR2 EXON Missense_T869A rs7850445 9 101063070 [A/G] NM_005458 GABBR2 Silent rs10985795 9 101065807 [T/C] NM_005458 GABBR2 Silent rs13290518 9 101066578 [T/G] NM_005458 GABBR2 Silent rs2304389 9 101068580 [A/G] NM_005458 GABBR2 EXON Synonymous_P684P rs10985817 9 101071090 [T/C] NM_005458 GABBR2 Silent rs3780446 9 101071562 [T/C] NM_005458 GABBR2 Silent rs12345664 9 101076088 [A/C] NM_005458 GABBR2 Silent rs13440299 9 101084042 [A/G] NM_005458 GABBR2 Silent rs7037275 9 101084087 [A/G] NM_005458 GABBR2 Silent rs11998914 9 101089739 [A/G] NM_005458 GABBR2 Silent rs3780438 9 101092018 [A/C] NM_005458 GABBR2 Silent rs16914931 9 101092316 [A/G] NM_005458 GABBR2 Silent rs16914943 9 101094353 [T/C] NM_005458 GABBR2 Silent rs879354 9 101094546 [T/C] NM_005458 GABBR2 Silent rs7871923 9 101097869 [T/C] NM_005458 GABBR2 Silent rs7874366 9 101101888 [A/G] NM_005458 GABBR2 Silent rs12236069 9 101102091 [A/G] NM_005458 GABBR2 Silent rs12553770 9 101102950 [A/G] NM_005458 GABBR2 Silent rs10760268 9 101104363 [A/G] NM_005458 GABBR2 Silent rs653873 9 101106398 [A/G] NM_005458 GABBR2 Silent rs471722 9 101113241 [T/G] NM_005458 GABBR2 Silent rs608900 9 101117385 [A/G] NM_005458 GABBR2 Silent rs514993 9 101125148 [T/C] NM_005458 GABBR2 Silent rs2572364 9 101126504 [T/G] NM_005458 GABBR2 Silent rs660148 9 101127379 [A/G] NM_005458 GABBR2 Silent rs3780429 9 101128858 [T/C] NM_005458 GABBR2 Silent rs3780428 9 101128916 [T/C] NM_005458 GABBR2 Silent rs7858926 9 101131753 [A/C] NM_005458 GABBR2 Silent rs585819 9 101132441 [T/C] NM_005458 GABBR2 Silent rs487910 9 101132481 [A/G] NM_005458 GABBR2 Silent rs583641 9 101132921 [A/C] NM_005458 GABBR2 Silent rs571569 9 101133138 [T/C] NM_005458 GABBR2 Silent rs567931 9 101133518 [T/C] NM_005458 GABBR2 Silent rs565349 9 101135075 [A/G] NM_005458 GABBR2 Silent rs10818832 9 101135643 [A/C] NM_005458 GABBR2 Silent rs661105 9 101137452 [A/G] NM_005458 GABBR2 Silent rs10818845 9 101138682 [A/G] NM_005458 GABBR2 Silent rs10760292 9 101138898 [A/G] NM_005458 GABBR2 Silent rs3780421 9 101143028 [A/G] NM_005458 GABBR2 Silent rs16915442 9 101144927 [T/C] NM_005458 GABBR2 Silent rs10986084 9 101147503 [T/C] NM_005458 GABBR2 Silent rs7034300 9 101158947 [A/G] NM_005458 GABBR2 Silent rs10986118 9 101164772 [A/G] NM_005458 GABBR2 Silent rs7020345 9 101168577 [A/G] NM_005458 GABBR2 Silent rs12235930 9 101171682 [A/G] NM_005458 GABBR2 Silent rs1537960 9 101172234 [A/G] NM_005458 GABBR2 Silent rs1537959 9 101172694 [T/C] NM_005458 GABBR2 Silent rs10818896 9 101174188 [T/C] NM_005458 GABBR2 Silent rs7022828 9 101176060 [A/G] NM_005458 GABBR2 Silent rs2900382 9 101177852 [T/C] NM_005458 GABBR2 Silent rs4743221 9 101178629 [A/C] NM_005458 GABBR2 Silent rs10986167 9 101179298 [T/C] NM_005458 GABBR2 Silent rs8181080 9 101179742 [A/G] NM_005458 GABBR2 Silent rs4743222 9 101188123 [T/C] NM_005458 GABBR2 Silent rs1537957 9 101192990 [T/C] NM_005458 GABBR2 Silent rs7466271 9 101202803 [T/C] NM_005458 GABBR2 Silent rs2491397 9 101205162 [T/C] NM_005458 GABBR2 Silent rs1415116 9 101207390 [A/C] NM_005458 GABBR2 Silent rs10986308 9 101210609 [T/C] NM_005458 GABBR2 Silent rs10818941 9 101211767 [A/G] NM_005458 GABBR2 Silent rs7042032 9 101212597 [T/C] NM_005458 GABBR2 Silent rs10818955 9 101218784 [T/C] NM_005458 GABBR2 Silent rs1930420 9 101219548 [T/C] NM_005458 GABBR2 Silent rs2808542 9 101219931 [A/G] NM_005458 GABBR2 Silent rs1930419 9 101220651 [T/C] NM_005458 GABBR2 Silent rs2808543 9 101221143 [A/G] NM_005458 GABBR2 Silent rs2808553 9 101229396 [T/C] NM_005458 GABBR2 Silent rs2151214 9 101230221 [A/C] NM_005458 GABBR2 Silent rs16916291 9 101230631 [T/C] NM_005458 GABBR2 Silent rs2779531 9 101231892 [A/G] NM_005458 GABBR2 Silent rs12554364 9 101235046 [A/G] NM_005458 GABBR2 Silent rs3750348 9 101235323 [T/C] NM_005458 GABBR2 Silent rs1930416 9 101238684 [A/C] NM_005458 GABBR2 Silent rs1930415 9 101238974 [T/C] NM_005458 GABBR2 Silent rs2779548 9 101243852 [T/C] NM_005458 GABBR2 Silent rs13295431 9 101248083 [T/C] NM_005458 GABBR2 Silent rs16916419 9 101248698 [T/G] NM_005458 GABBR2 Silent rs872091 9 101249102 [A/G] NM_005458 GABBR2 Silent rs874278 9 101249423 [A/G] NM_005458 GABBR2 Silent rs2779551 9 101253226 [T/C] NM_005458 GABBR2 Silent rs2779552 9 101254476 [A/C] NM_005458 GABBR2 Silent rs16916507 9 101258803 [A/G] NM_005458 GABBR2 Silent rs1000440 9 101258881 [T/C] NM_005458 GABBR2 Silent rs2779556 9 101265290 [A/C] NM_005458 GABBR2 Silent rs12552067 9 101266669 [A/G] NM_005458 GABBR2 Silent rs10986473 9 101267927 [T/C] NM_005458 GABBR2 Silent rs2779558 9 101269571 [T/C] NM_005458 GABBR2 Silent rs13295101 9 101270230 [T/C] NM_005458 GABBR2 Silent rs7857375 9 101277609 [A/G] NM_005458 GABBR2 Silent rs2779562 9 101277681 [T/C] NM_005458 GABBR2 Silent rs1930409 9 101278541 [T/C] NM_005458 GABBR2 Silent rs944761 9 101279351 [T/C] NM_005458 GABBR2 Silent rs16916777 9 101281175 [A/G] NM_005458 GABBR2 Silent rs2779572 9 101281710 [T/G] NM_005458 GABBR2 Silent rs7874983 9 101281729 [T/C] NM_005458 GABBR2 Silent rs2095121 9 101284111 [A/G] NM_005458 GABBR2 Silent rs10760389 9 101289991 [T/C] NM_005458 GABBR2 Silent rs10986577 9 101293382 [T/C] NM_005458 GABBR2 Silent rs4237192 9 101297144 [A/G] NM_005458 GABBR2 Silent rs11787646 9 101298707 [A/G] NM_005458 GABBR2 Silent rs2779600 9 101300786 [A/G] NM_005458 GABBR2 Silent rs2779602 9 101303077 [A/G] NM_005458 GABBR2 Silent rs2808521 9 101303770 [T/C] NM_005458 GABBR2 Silent rs2184026 9 101304348 [T/C] NM_005458 GABBR2 Silent rs10819042 9 101307334 [T/G] NM_005458 GABBR2 Silent rs1999498 9 101308111 [A/G] NM_005458 GABBR2 Silent rs16917019 9 101313371 [T/C] NM_005458 GABBR2 Silent rs2259639 9 101317401 [T/C] NM_005458 GABBR2 Silent rs2900512 9 101317921 [T/C] NM_005458 GABBR2 Silent rs884886 9 101318075 [T/G] NM_005458 GABBR2 Silent rs10986740 9 101320582 [A/G] NM_005458 GABBR2 Silent rs1167767 9 101328200 [T/G] NM_005458 GABBR2 Silent rs6478761 9 101329894 [A/C] NM_005458 GABBR2 Silent rs928425 9 101333453 [A/G] NM_005458 GABBR2 Silent rs7044074 9 101333901 [T/C] NM_005458 GABBR2 Silent rs1167769 9 101334556 [A/G] NM_005458 GABBR2 Silent rs2779523 9 101334945 [T/G] NM_005458 GABBR2 Silent rs1179740 9 101336041 [T/G] NM_005458 GABBR2 Silent rs1758799 9 101339690 [T/C] NM_005458 GABBR2 Silent rs2808534 9 101339947 [A/G] NM_005458 GABBR2 Silent rs3750344 9 101340316 [T/C] NM_005458 GABBR2 EXON Synonymous_A120A rs10986816 9 101341534 [T/C] NM_005458 GABBR2 Silent rs2779527 9 101344340 [A/G] NM_005458 GABBR2 Silent rs2778908 9 101345778 [A/G] NM_005458 GABBR2 Silent rs1167763 9 101346168 [T/C] NM_005458 GABBR2 Silent rs10123407 9 101346548 [A/C] NM_005458 GABBR2 Silent rs12337255 9 101347219 [T/C] NM_005458 GABBR2 Silent rs2779529 9 101350077 [A/C] NM_005458 GABBR2 Silent rs7860298 9 101351051 [A/G] NM_005458 GABBR2 Silent rs10986852 9 101351818 [T/C] NM_005458 GABBR2 Silent rs13301129 9 101355381 [A/G] NM_005458 GABBR2 Silent rs2808539 9 101355624 [T/C] NM_005458 GABBR2 Silent rs1999500 9 101356515 [T/C] NM_005458 GABBR2 Silent rs7035372 9 101356663 [A/G] NM_005458 GABBR2 Silent rs2808541 9 101357407 [T/C] NM_005458 GABBR2 Silent rs10819071 9 101361447 [T/C] NM_005458 GABBR2 Silent rs10819072 9 101361584 [A/C] NM_005458 GABBR2 Silent rs914662 9 101363329 [T/C] NM_005458 GABBR2 Silent rs944689 9 101366538 [T/C] NM_005458 GABBR2 Silent rs1930421 9 101375948 [A/G] NM_005458 GABBR2 Silent rs4327958 9 101377032 [T/G] NM_005458 GABBR2 Silent rs2778913 9 101379780 [T/C] NM_005458 GABBR2 Silent rs1167774 9 101382838 [T/G] NM_005458 GABBR2 Silent rs6478785 9 101384719 [T/G] NM_005458 GABBR2 Silent rs1930130 9 101385839 [T/C] NM_005458 GABBR2 Silent rs1930131 9 101389408 [T/C] NM_005458 GABBR2 Silent rs1547272 9 101392755 [T/C] NM_005458 GABBR2 Silent rs6478792 9 101401471 [A/G] NM_005458 GABBR2 Silent rs16917763 9 101403758 [A/C] NM_005458 GABBR2 Silent rs7869482 9 101404349 [A/G] NM_005458 GABBR2 Silent rs7864144 9 101406038 [A/G] NM_005458 GABBR2 Silent rs1930135 9 101411132 [T/C] NM_005458 GABBR2 Silent rs1967890 9 101417785 [A/C] NM_005458 GABBR2 Silent rs12002737 9 101427651 [A/C] NM_005458 GABBR2 Silent rs7865785 9 101427796 [A/G] NM_005458 GABBR2 Silent rs1930136 9 101433268 [T/C] NM_005458 GABBR2 Silent rs10116255 9 101436021 [A/G] NM_005458 GABBR2 Silent rs914667 9 101436463 [T/C] NM_005458 GABBR2 Silent rs1105931 9 101436894 [T/C] NM_005458 GABBR2 Silent rs1547271 9 101437009 [T/C] NM_005458 GABBR2 Silent rs4517239 9 101454321 [A/G] NM_005458 GABBR2 Silent rs10760475 9 101489665 [A/C] rs380857 9 101491066 [A/C] rs13299320 9 101493968 [T/G] rs10987565 9 101494214 [T/C] rs439347 9 101496346 [A/G] NM_173551 ANKS6 EXON Silent rs337589 9 101496508 [A/G] NM_173551 ANKS6 EXON Silent rs337587 9 101497796 [T/C] NM_173551 ANKS6 EXON Silent rs16917884 9 101507149 [A/G] NM_173551 ANKS6 Silent rs580809 9 101518442 [T/C] NM_173551 ANKS6 Silent rs422531 9 101519554 [T/C] NM_173551 ANKS6 Silent rs6415847 9 101533220 [T/C] NM_173551 ANKS6 EXON Missense_V644I rs10819300 9 101533973 [T/C] NM_173551 ANKS6 Silent rs12686258 9 101534397 [T/C] NM_173551 ANKS6 Silent rs4742741 9 101539601 [A/G] NM_173551 ANKS6 Silent rs7853904 9 101550367 [A/G] NM_173551 ANKS6 Silent rs7027771 9 101552955 [T/C] NM_173551 ANKS6 Silent rs7038640 9 101553014 [T/G] NM_173551 ANKS6 Silent rs11790900 9 101568727 [A/G] rs2295925 9 101585992 [A/G] NM_024642 GALNT12 Silent rs911928 9 101590318 [A/G] NM_024642 GALNT12 Silent rs2295926 9 101593825 [T/C] NM_024642 GALNT12 Silent rs16917929 9 101594219 [A/G] NM_024642 GALNT12 EXON Synonymous_Q299Q rs10987898 9 101595443 [T/G] NM_024642 GALNT12 Silent rs1407503 9 101598609 [A/G] NM_024642 GALNT12 Silent rs4743285 9 101599758 [A/G] NM_024642 GALNT12 Silent rs999471 9 101601645 [T/C] NM_024642 GALNT12 Silent rs10819375 9 101602944 [T/C] NM_024642 GALNT12 Silent rs10819377 9 101603712 [T/C] NM_024642 GALNT12 Silent rs10987949 9 101607247 [A/G] NM_024642 GALNT12 Silent rs10987952 9 101608025 [A/C] NM_024642 GALNT12 Silent rs7858352 9 101608643 [T/C] NM_024642 GALNT12 Silent rs7873605 9 101608735 [A/G] NM_024642 GALNT12 Silent rs2295928 9 101609706 [T/C] NM_024642 GALNT12 Silent rs2295929 9 101609768 [T/G] NM_024642 GALNT12 Silent rs1322540 9 101619191 [T/C] rs7864581 9 101619403 [A/G] rs1157248 9 101623189 [A/G] rs10987993 9 101625377 [T/C] rs7875364 9 101627022 [A/G] rs10819389 9 101629751 [T/C] rs10739724 9 101629892 [A/G] rs7855317 9 101633298 [A/G] rs2295932 9 101634716 [T/C] rs10819414 9 101639369 [A/G] rs10988060 9 101642376 [A/G] rs1407508 9 101644538 [T/C] rs16917989 9 101647469 [A/C] rs1007892 9 101649752 [T/G] rs1028653 9 101651948 [A/G] rs1028655 9 101652106 [A/G] rs16918004 9 101652655 [T/C] rs2416541 9 101655952 [A/G] rs927468 9 101661037 [A/G] rs10819451 9 101667612 [T/C] rs7470221 9 101678036 [T/C] rs10123556 9 101678096 [T/C] rs716573 9 101678273 [T/C] rs11787951 9 101680380 [T/G] rs17710605 9 101685450 [A/G] rs10819460 9 101685520 [T/C] rs1555521 9 101687361 [T/C] rs10114761 9 101688707 [A/G] rs2065598 9 101691988 [A/C] rs10819472 9 101694958 [T/G] rs17783501 9 101697289 [A/C] rs16918081 9 101697350 [T/C] rs911933 9 101707174 [T/C] NM_001855 COL15A1 Silent rs10819482 9 101707390 [T/G] NM_001855 COL15A1 Silent rs6478963 9 101708150 [T/C] NM_001855 COL15A1 Silent rs16918099 9 101715598 [A/G] NM_001855 COL15A1 Silent rs7874124 9 101720921 [T/G] NM_001855 COL15A1 Silent rs2050257 9 101727615 [A/G] NM_001855 COL15A1 Silent rs2151616 9 101729103 [A/G] NM_001855 COL15A1 Silent rs10819537 9 101734465 [T/C] NM_001855 COL15A1 Silent rs989393 9 101743336 [T/C] NM_001855 COL15A1 Silent rs2075662 9 101748234 [A/G] NM_001855 COL15A1 EXON Missense_R163H rs4742754 9 101748356 [A/G] NM_001855 COL15A1 EXON Missense_M204V rs1023249 9 101752484 [A/G] NM_001855 COL15A1 Silent rs10988510 9 101758352 [A/G] NM_001855 COL15A1 Silent rs3818760 9 101759372 [A/G] NM_001855 COL15A1 Silent rs1413299 9 101761241 [T/G] NM_001855 COL15A1 Silent rs2274963 9 101763091 [T/C] NM_001855 COL15A1 Silent rs3780622 9 101763633 [A/G] NM_001855 COL15A1 Silent rs16918128 9 101767303 [A/G] NM_001855 COL15A1 EXON Missense_A442T rs1889268 9 101767961 [T/C] NM_001855 COL15A1 Silent rs914993 9 101768916 [A/C] NM_001855 COL15A1 Silent rs4743309 9 101779824 [T/C] NM_001855 COL15A1 Silent rs10819587 9 101781301 [A/G] NM_001855 COL15A1 Silent rs1041631 9 101781858 [A/G] NM_001855 COL15A1 Silent rs4743310 9 101782535 [T/C] NM_001855 COL15A1 Silent rs3739799 9 101784777 [T/C] NM_001855 COL15A1 Silent rs12552765 9 101785207 [A/G] NM_001855 COL15A1 Silent rs7848837 9 101785558 [T/G] NM_001855 COL15A1 Silent rs7851787 9 101785633 [T/C] NM_001855 COL15A1 Silent rs4742755 9 101790933 [A/G] NM_001855 COL15A1 Silent rs12684946 9 101792716 [A/G] NM_001855 COL15A1 Silent rs7863250 9 101793834 [T/C] NM_001855 COL15A1 Silent rs976240 9 101797043 [A/G] NM_001855 COL15A1 Silent rs2075666 9 101798002 [T/C] NM_001855 COL15A1 Silent rs7854112 9 101804329 [T/C] NM_001855 COL15A1 EXON Synonymous_G838G rs928522 9 101807463 [T/C] NM_001855 COL15A1 Silent rs869776 9 101810339 [T/C] NM_001855 COL15A1 Silent rs13296166 9 101812072 [A/G] NM_001855 COL15A1 Silent rs16918167 9 101815339 [T/G] NM_001855 COL15A1 Silent rs2067986 9 101816399 [T/C] NM_001855 COL15A1 Silent rs3824511 9 101816552 [T/C] NM_001855 COL15A1 Silent rs12001981 9 101820545 [A/G] NM_001855 COL15A1 Silent rs1537506 9 101821169 [T/C] NM_001855 COL15A1 Silent rs7031588 9 101822302 [T/C] NM_001855 COL15A1 Silent rs1360686 9 101823327 [A/G] NM_001855 COL15A1 Silent rs1413298 9 101823373 [A/G] NM_001855 COL15A1 Silent rs1051105 9 101832442 [A/G] NM_001855 COL15A1 EXON Silent rs914991 9 101834340 [A/C] rs4743322 9 101835165 [A/C] rs2416666 9 101844549 [A/G] rs7874183 9 101848586 [A/G] rs7034716 9 101858382 [T/C] rs10819634 9 101860076 [T/C] rs12686783 9 101861767 [T/C] rs11568742 9 101866291 [T/C] rs10739778 9 101875789 [A/C] NM_001130916,NM_001306210,NM_004612 TGFBR1,TGFBR1,TGFBR1 Silent,Silent,Silent rs10739779 9 101882199 [A/C] NM_001130916,NM_001306210,NM_004612 TGFBR1,TGFBR1,TGFBR1 Silent,Silent,Silent rs10512263 9 101886071 [T/C] NM_001130916,NM_001306210,NM_004612 TGFBR1,TGFBR1,TGFBR1 Silent,Silent,Silent rs11568753 9 101890227 [T/C] NM_001130916,NM_001306210,NM_004612 TGFBR1,TGFBR1,TGFBR1 Silent,Silent,Silent rs10283455 9 101905643 [T/G] NM_001130916,NM_001306210,NM_004612 TGFBR1,TGFBR1,TGFBR1 Silent,Silent,Silent rs10733710 9 101907424 [A/G] NM_001130916,NM_001306210,NM_004612 TGFBR1,TGFBR1,TGFBR1 Silent,Silent,Silent rs334348 9 101912471 [A/G] NM_001130916,NM_001306210,NM_004612 TGFBR1,TGFBR1,TGFBR1 EXON Silent,Silent,Silent rs17724567 9 101914232 [A/C] NM_001130916,NM_001306210,NM_004612 TGFBR1,TGFBR1,TGFBR1 EXON Silent,Silent,Silent rs334349 9 101914387 [A/G] NM_001130916,NM_001306210,NM_004612 TGFBR1,TGFBR1,TGFBR1 EXON Silent,Silent,Silent rs3739798 9 101914812 [A/G] NM_001130916,NM_001306210,NM_004612 TGFBR1,TGFBR1,TGFBR1 EXON Silent,Silent,Silent rs7850895 9 101916076 [T/C] NM_001130916,NM_001306210,NM_004612 TGFBR1,TGFBR1,TGFBR1 EXON Silent,Silent,Silent rs1590 9 101916165 [T/G] NM_001130916,NM_001306210,NM_004612 TGFBR1,TGFBR1,TGFBR1 EXON Silent,Silent,Silent rs385057 9 101922412 [T/C] rs334362 9 101926594 [A/G] rs334363 9 101928702 [A/C] rs7035064 9 101931740 [A/G] rs7022989 9 101933170 [T/G] rs10819641 9 101936231 [T/C] rs10121020 9 101946041 [T/C] rs10988744 9 101952798 [T/C] rs12115551 9 101969058 [A/G] rs701376 9 101974824 [A/G] rs10819642 9 101976992 [T/C] rs12554447 9 101983182 [T/C] NM_033087,NR_024532 ALG2,ALG2 Silent,Silent rs7036164 9 101986627 [A/G] NM_006808 SEC61B Silent rs3780616 9 101987760 [A/G] NM_006808 SEC61B Silent rs17725608 9 101995174 [A/G] rs17725644 9 101999398 [T/G] rs1746154 9 102021226 [A/G] rs228635 9 102029791 [A/G] rs162628 9 102033964 [A/G] rs182762 9 102036913 [A/G] rs189042 9 102039043 [A/G] rs692905 9 102049363 [T/C] rs12001129 9 102054850 [A/G] rs451008 9 102056001 [T/C] rs431892 9 102056057 [T/C] rs162624 9 102059951 [A/G] rs1746147 9 102061199 [T/C] rs1699421 9 102062681 [A/G] rs1622127 9 102063150 [A/C] rs7047384 9 102066983 [T/C] rs10988763 9 102076659 [A/G] rs170463 9 102079390 [A/G] rs379029 9 102079670 [A/G] rs10760678 9 102079941 [A/G] rs4268186 9 102081002 [T/C] rs10117464 9 102084670 [A/G] rs390312 9 102086148 [A/G] rs420258 9 102092282 [A/G] rs1323468 9 102100078 [A/G] rs7042978 9 102101485 [A/G] rs17794662 9 102111011 [T/C] rs323729 9 102116594 [A/G] rs415960 9 102117925 [T/G] NR_102270,NR_102271 NAMA,NAMA Silent,Silent rs12551906 9 102119090 [A/G] NR_102270,NR_102271 NAMA,NAMA Silent,Silent rs323721 9 102123746 [T/C] NR_102270,NR_102271 NAMA,NAMA Silent,Silent rs1746153 9 102127067 [A/G] NR_102270,NR_102271 NAMA,NAMA Silent,Silent rs10819657 9 102128509 [T/C] NR_102270,NR_102271 NAMA,NAMA Silent,Silent rs7024617 9 102139440 [T/C] rs10491654 9 102139527 [T/C] rs894674 9 102143101 [T/C] rs9299331 9 102146915 [T/C] rs12555122 9 102151801 [A/G] rs10988794 9 102152364 [T/C] rs10988801 9 102159382 [A/C] rs2416771 9 102159610 [T/C] rs880597 9 102168293 [T/C] rs2034105 9 102169125 [A/C] rs4743350 9 102177648 [A/G] rs10760682 9 102179061 [A/G] rs10512264 9 102182953 [A/G] rs10760683 9 102190045 [T/C] rs10512267 9 102190129 [T/C] rs634202 9 102233287 [A/G] rs649057 9 102234323 [A/C] rs10760688 9 102247368 [A/G] rs9299333 9 102271150 [A/G] rs16918618 9 102275382 [A/G] rs10819683 9 102277921 [A/G] rs7874483 9 102278511 [T/C] rs7044788 9 102289651 [T/C] rs13298309 9 102304304 [T/C] rs11794164 9 102336962 [A/C] rs11788118 9 102337331 [A/G] rs10988865 9 102342950 [T/C] rs10819687 9 102346029 [A/C] rs7866140 9 102354364 [T/G] NR_109802 LOC101928438 Silent rs4743361 9 102374475 [A/G] NR_109802 LOC101928438 Silent rs4743363 9 102383474 [T/C] NR_109802 LOC101928438 Silent rs10819689 9 102400263 [T/C] NR_109802 LOC101928438 Silent rs7857193 9 102407049 [T/C] NR_109802 LOC101928438 Silent rs28737332 9 102426699 [A/G] NR_109802 LOC101928438 Silent rs1578463 9 102464577 [T/C] NR_109802 LOC101928438 Silent rs1147312 9 102473442 [A/C] NR_109802 LOC101928438 Silent rs10819691 9 102473991 [T/C] NR_109802 LOC101928438 Silent rs17798928 9 102502572 [A/G] NR_109802 LOC101928438 Silent rs10988890 9 102528667 [A/G] NR_109802 LOC101928438 Silent rs10819694 9 102540372 [T/C] NR_109802 LOC101928438 Silent rs7026022 9 102562216 [A/C] NR_109802 LOC101928438 Silent rs13295822 9 102575680 [A/G] NR_109802 LOC101928438 Silent rs1856928 9 102583645 [A/C] rs1405209 9 102585545 [T/C] NM_173200,NM_006981,NM_173199 NR4A3,NR4A3,NR4A3 Silent,Silent,Silent rs10988904 9 102595685 [T/C] NM_173200,NM_006981,NM_173199 NR4A3,NR4A3,NR4A3 EXON Synonymous_A412A,Synonymous_A401A,Synonymous_A401A rs2900223 9 102596321 [A/G] NM_173200,NM_006981,NM_173199 NR4A3,NR4A3,NR4A3 EXON Silent,Silent,Silent rs10988906 9 102613056 [A/C] NM_173200,NM_006981 NR4A3,NR4A3 Silent,Silent rs12344655 9 102615214 [T/C] NM_173200,NM_006981 NR4A3,NR4A3 Silent,Silent rs7847479 9 102622237 [T/C] NM_173200,NM_006981 NR4A3,NR4A3 Silent,Silent rs1131339 9 102627302 [A/G] NM_173200,NM_006981 NR4A3,NR4A3 EXON Silent,Silent rs10819700 9 102635520 [T/C] rs1962051 9 102669877 [T/G] NM_017919 STX17 Silent rs4742777 9 102679173 [T/C] NM_017919 STX17 Silent rs4428721 9 102686487 [T/C] NM_017919 STX17 Silent rs10117638 9 102687082 [T/C] NM_017919 STX17 Silent rs10124366 9 102687703 [A/G] NM_017919 STX17 Silent rs10512268 9 102714466 [A/G] NM_017919 STX17 Silent rs10760706 9 102723692 [T/C] NM_017919 STX17 Silent rs9556 9 102732237 [T/C] NM_017919 STX17 EXON Silent rs1055187 9 102733298 [T/C] NM_017919 STX17 EXON Silent rs2698999 9 102735865 [A/C] NM_017919 STX17 EXON Silent rs17738574 9 102741335 [T/C] rs2795575 9 102741475 [A/G] NM_015051 ERP44 EXON Silent rs10760708 9 102748197 [A/C] NM_015051 ERP44 Silent rs10988943 9 102773356 [T/C] NM_015051 ERP44 Silent rs10819717 9 102777978 [A/C] NM_015051 ERP44 Silent rs10156395 9 102813042 [T/C] NM_015051 ERP44 Silent rs7867803 9 102816535 [T/C] NM_015051 ERP44 Silent rs10739795 9 102826067 [T/C] NM_015051 ERP44 Silent rs16918878 9 102846630 [T/C] NM_015051 ERP44 Silent rs10988967 9 102849539 [A/C] NM_015051 ERP44 Silent rs7024375 9 102861613 [T/G] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS EXON Silent,Silent,Silent,Silent rs12346672 9 102868769 [A/G] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS Silent,Silent,Silent,Silent rs846761 9 102886948 [A/G] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS Silent,Silent,Silent,Silent rs1415927 9 102911706 [T/C] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS Silent,Silent,Silent,Silent rs10988996 9 102939193 [A/G] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS Silent,Silent,Silent,Silent rs7020780 9 102958736 [A/G] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS Silent,Silent,Silent,Silent rs1999877 9 102973719 [A/C] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS Silent,Silent,Silent,Silent rs4273907 9 102977295 [T/C] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS Silent,Silent,Silent,Silent rs2491097 9 103002451 [T/C] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS EXON Missense_S242L,Silent,Silent,Missense_S146L rs2787394 9 103007414 [T/C] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS Silent,Silent,Silent,Silent rs2787390 9 103013986 [A/G] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS Silent,Silent,Silent,Silent rs2787372 9 103050407 [T/C] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS Silent,Silent,Silent,Silent rs2787374 9 103054951 [T/C] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS EXON Synonymous_S804S,Silent,Synonymous_S478S,Synonymous_S708S rs2806700 9 103055997 [T/G] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS Silent,Silent,Silent,Silent rs10123866 9 103063645 [A/G] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS EXON Silent,Silent,Silent,Silent rs10123913 9 103063826 [T/G] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS EXON Silent,Silent,Silent,Silent rs10989049 9 103064153 [A/G] NM_014425,NR_134606,NM_001318382,NM_001318381 INVS,INVS,INVS,INVS EXON Silent,Silent,Silent,Silent rs3923501 9 103065884 [T/C] NM_001161584,NM_017746 TEX10,TEX10 Silent,Silent rs10819758 9 103085570 [T/G] NM_001161584,NM_017746 TEX10,TEX10 Silent,Silent rs6479013 9 103091805 [A/G] NM_001161584,NM_017746 TEX10,TEX10 Silent,Silent rs17740117 9 103099117 [A/G] NM_001161584,NM_017746 TEX10,TEX10 Silent,Silent rs10989072 9 103138400 [T/C] rs2026999 9 103140157 [T/C] rs10819769 9 103147531 [A/G] rs13284428 9 103149987 [T/C] rs953381 9 103151524 [T/C] rs12000794 9 103157515 [A/C] rs16919104 9 103164224 [T/C] rs10989081 9 103173304 [T/C] rs7031884 9 103174029 [A/C] rs10819774 9 103179614 [T/C] rs2026998 9 103181596 [A/C] rs5018733 9 103188632 [T/G] rs11790432 9 103191461 [A/G] NM_080655,NM_001198807,NM_001198805 MSANTD3,MSANTD3,MSANTD3 Silent,Silent,Silent rs7871912 9 103207142 [A/G] NM_080655,NM_001198807,NM_001198805,NM_001198806,NM_001198812 MSANTD3,MSANTD3,MSANTD3,MSANTD3,MSANTD3-TMEFF1 Silent,Silent,Silent,Silent,Silent rs16919111 9 103208699 [A/G] NM_080655,NM_001198807,NM_001198805,NM_001198806,NM_001198812 MSANTD3,MSANTD3,MSANTD3,MSANTD3,MSANTD3-TMEFF1 Silent,Silent,Silent,Silent,Silent rs12337571 9 103209342 [A/G] NM_080655,NM_001198807,NM_001198805,NM_001198806,NM_001198812 MSANTD3,MSANTD3,MSANTD3,MSANTD3,MSANTD3-TMEFF1 Silent,Silent,Silent,Silent,Silent rs7046659 9 103211325 [T/C] NM_080655,NM_001198807,NM_001198805,NM_001198806,NM_001198812 MSANTD3,MSANTD3,MSANTD3,MSANTD3,MSANTD3-TMEFF1 Silent,Silent,Silent,Silent,Silent rs10989097 9 103211802 [T/G] NM_080655,NM_001198807,NM_001198805,NM_001198806,NM_001198812 MSANTD3,MSANTD3,MSANTD3,MSANTD3,MSANTD3-TMEFF1 Silent,Silent,Silent,Silent,Silent rs12683548 9 103212528 [T/C] NM_080655,NM_001198807,NM_001198805,NM_001198806,NM_001198812 MSANTD3,MSANTD3,MSANTD3,MSANTD3,MSANTD3-TMEFF1 Silent,Silent,Silent,Silent,Silent rs12001823 9 103212744 [A/G] NM_080655,NM_001198807,NM_001198805,NM_001198806,NM_001198812 MSANTD3,MSANTD3,MSANTD3,MSANTD3,MSANTD3-TMEFF1 Silent,Silent,Silent,Silent,Silent rs1556487 9 103213947 [A/G] NM_080655,NM_001198807,NM_001198805,NM_001198806,NM_001198812 MSANTD3,MSANTD3,MSANTD3,MSANTD3,MSANTD3-TMEFF1 EXON Silent,Silent,Silent,Silent,Silent rs17813801 9 103218013 [T/G] NM_001198812 MSANTD3-TMEFF1 Silent rs7869933 9 103227676 [T/C] NM_001198812 MSANTD3-TMEFF1 Silent rs7041189 9 103240259 [A/G] NM_001198812,NM_003692 MSANTD3-TMEFF1,TMEFF1 Silent,Silent rs10989112 9 103252812 [T/C] NM_001198812,NM_003692 MSANTD3-TMEFF1,TMEFF1 Silent,Silent rs10819788 9 103262228 [A/G] NM_001198812,NM_003692 MSANTD3-TMEFF1,TMEFF1 Silent,Silent rs10989146 9 103299435 [A/G] NM_001198812,NM_003692 MSANTD3-TMEFF1,TMEFF1 Silent,Silent rs2274882 9 103312290 [A/C] NM_001198812,NM_003692 MSANTD3-TMEFF1,TMEFF1 Silent,Silent rs16919174 9 103314417 [T/G] NM_001198812,NM_003692 MSANTD3-TMEFF1,TMEFF1 Silent,Silent rs10989153 9 103319797 [A/G] NM_001198812,NM_003692 MSANTD3-TMEFF1,TMEFF1 Silent,Silent rs17741974 9 103324710 [T/C] NM_001198812,NM_003692 MSANTD3-TMEFF1,TMEFF1 Silent,Silent rs12005789 9 103331141 [A/G] NM_001198812,NM_003692 MSANTD3-TMEFF1,TMEFF1 Silent,Silent rs2800284 9 103338012 [T/G] NM_001198812,NM_003692 MSANTD3-TMEFF1,TMEFF1 Silent,Silent rs13295029 9 103338172 [A/G] NM_001198812,NM_003692 MSANTD3-TMEFF1,TMEFF1 Silent,Silent rs1226591 9 103340309 [T/C] rs1226588 9 103341014 [A/G] NM_001018116 CAVIN4 Silent rs2151598 9 103342983 [A/G] NM_001018116 CAVIN4 Silent rs2780958 9 103343852 [A/G] NM_001018116 CAVIN4 Silent rs11791916 9 103348998 [A/G] NM_001018116 CAVIN4 EXON Silent rs10989163 9 103349568 [A/G] NM_001018116 CAVIN4 EXON Silent rs17742650 9 103351014 [A/G] rs1226593 9 103353017 [T/G] rs10989168 9 103361114 [A/G] rs10989173 9 103364064 [T/C] rs7022319 9 103365585 [T/C] rs10989174 9 103366326 [A/G] rs4474081 9 103367615 [A/C] rs10118164 9 103370505 [A/G] rs10115383 9 103370532 [A/G] rs10760729 9 103371976 [T/C] rs4743404 9 103375024 [T/G] rs7869768 9 103377514 [A/G] rs10819800 9 103383109 [T/G] rs6479020 9 103386660 [T/G] rs7036906 9 103388556 [A/C] rs7853484 9 103391639 [T/C] rs1106382 9 103403174 [T/C] rs1936641 9 103405197 [A/G] rs4330746 9 103412206 [T/C] rs12238759 9 103427155 [T/C] rs10114244 9 103427659 [T/C] rs10114272 9 103427741 [T/C] rs1936638 9 103428300 [A/G] rs10989208 9 103433868 [T/G] rs10819806 9 103437984 [A/G] rs4512437 9 103439019 [A/G] rs10819808 9 103446253 [A/G] rs2417203 9 103448341 [A/C] rs10123021 9 103452068 [T/G] rs7875828 9 103459867 [A/C] rs13285837 9 103461210 [A/G] rs1892128 9 103474052 [A/G] rs12346541 9 103480387 [A/G] rs6479028 9 103485133 [T/G] rs7853739 9 103485819 [A/C] rs10989224 9 103486169 [T/C] rs4415379 9 103486336 [T/C] rs10521052 9 103488590 [T/G] rs7027190 9 103490384 [A/G] rs13302189 9 103493958 [A/G] rs4742792 9 103494116 [T/C] rs7854792 9 103495396 [T/C] rs10989231 9 103495889 [A/G] rs1578041 9 103513029 [A/G] rs10819824 9 103514183 [T/C] rs10739802 9 103517896 [A/G] rs7019439 9 103518490 [T/C] rs16919422 9 103520190 [T/C] rs7024267 9 103521788 [T/C] rs10819829 9 103524447 [T/C] rs10989249 9 103532305 [A/G] rs10760755 9 103534708 [T/C] rs1933794 9 103536801 [T/C] rs2211079 9 103539701 [A/G] rs10760761 9 103545694 [A/G] rs4742795 9 103545759 [A/C] rs10113967 9 103556016 [A/G] rs10739807 9 103558414 [A/G] rs12353100 9 103564103 [A/G] rs1338729 9 103571388 [A/G] rs1338736 9 103573103 [A/G] rs1538410 9 103578202 [A/G] rs7861739 9 103582699 [A/C] rs7034844 9 103585379 [A/G] rs10819849 9 103591484 [T/G] rs7868230 9 103598789 [T/G] rs10512274 9 103603201 [A/G] rs1953805 9 103603365 [A/C] rs1953807 9 103603761 [T/G] rs10819859 9 103620015 [T/C] rs16919567 9 103624177 [T/C] rs10760775 9 103644950 [T/C] rs7849545 9 103648842 [T/C] rs10819865 9 103651056 [A/G] rs1338733 9 103658148 [A/G] rs10819866 9 103660338 [A/G] rs1547689 9 103665363 [T/C] rs12552974 9 103675913 [A/G] rs13285273 9 103691860 [A/G] rs16919646 9 103694660 [A/G] rs10819885 9 103701886 [A/G] rs12551278 9 103704579 [T/C] rs10989329 9 103715080 [A/G] rs607449 9 103717654 [A/G] rs2245719 9 103728088 [T/G] rs2250068 9 103741404 [A/G] rs2486370 9 103749454 [T/G] rs7027880 9 103750927 [A/G] rs13297102 9 103763948 [A/G] rs1330193 9 103769373 [T/C] rs628371 9 103779613 [T/G] rs7864653 9 103781123 [A/G] rs16919732 9 103784962 [T/C] rs654414 9 103787416 [T/C] rs2486381 9 103790352 [T/C] rs2251885 9 103793544 [A/G] NM_207299 PLPPR1 Silent rs649414 9 103794247 [T/G] NM_207299 PLPPR1 Silent rs649892 9 103794389 [T/G] NM_207299 PLPPR1 Silent rs2252151 9 103796067 [T/C] NM_207299 PLPPR1 Silent rs12686256 9 103796590 [T/C] NM_207299 PLPPR1 Silent rs2480736 9 103797594 [A/G] NM_207299 PLPPR1 Silent rs2012728 9 103801806 [A/G] NM_207299 PLPPR1 Silent rs10989360 9 103803109 [T/C] NM_207299 PLPPR1 Silent rs2256081 9 103805207 [T/C] NM_207299 PLPPR1 Silent rs476599 9 103809117 [T/C] NM_207299 PLPPR1 Silent rs10116092 9 103811847 [T/C] NM_207299 PLPPR1 Silent rs16919778 9 103829867 [A/G] NM_207299 PLPPR1 Silent rs12344189 9 103833944 [A/G] NM_207299 PLPPR1 Silent rs495837 9 103835968 [A/G] NM_207299 PLPPR1 Silent rs10989383 9 103839683 [A/G] NM_207299 PLPPR1 Silent rs624169 9 103840814 [A/G] NM_207299 PLPPR1 Silent rs1339422 9 103848006 [T/C] NM_207299 PLPPR1 Silent rs1339424 9 103848261 [T/C] NM_207299 PLPPR1 Silent rs10989391 9 103848764 [T/C] NM_207299 PLPPR1 Silent rs10989395 9 103851372 [A/G] NM_207299 PLPPR1 Silent rs10120384 9 103857465 [T/C] NM_207299 PLPPR1 Silent rs7848935 9 103858565 [A/C] NM_207299 PLPPR1 Silent rs10819899 9 103859537 [T/C] NM_207299 PLPPR1 Silent rs2993805 9 103861352 [A/G] NM_207299 PLPPR1 Silent rs1329082 9 103864180 [T/G] NM_207299 PLPPR1 Silent rs7037253 9 103870616 [T/C] NM_207299 PLPPR1 Silent rs12236239 9 103871680 [A/G] NM_207299 PLPPR1 Silent rs716157 9 103872326 [T/G] NM_207299 PLPPR1 Silent rs7467823 9 103872681 [A/G] NM_207299 PLPPR1 Silent rs10819903 9 103873057 [T/C] NM_207299 PLPPR1 Silent rs1410854 9 103873786 [T/C] NM_207299 PLPPR1 Silent rs2993807 9 103874937 [T/C] NM_207299 PLPPR1 Silent rs10156478 9 103875396 [A/C] NM_207299 PLPPR1 Silent rs2993808 9 103876273 [A/G] NM_207299 PLPPR1 Silent rs3983746 9 103877068 [A/G] NM_207299 PLPPR1 Silent rs10760791 9 103878207 [A/G] NM_207299 PLPPR1 Silent rs10989415 9 103894388 [T/C] NM_207299 PLPPR1 Silent rs16919936 9 103897410 [A/G] NM_207299 PLPPR1 Silent rs16919946 9 103901285 [A/G] NM_207299 PLPPR1 Silent rs3118941 9 103910778 [T/G] NM_207299 PLPPR1 Silent rs1431473 9 103912602 [A/G] NM_207299 PLPPR1 Silent rs7867688 9 103919670 [T/G] NM_207299 PLPPR1 Silent rs2771064 9 103920578 [A/G] NM_207299 PLPPR1 Silent rs2987746 9 103921194 [A/G] NM_207299 PLPPR1 Silent rs16919990 9 103922841 [T/G] NM_207299 PLPPR1 Silent rs438403 9 103923185 [A/G] NM_207299 PLPPR1 Silent rs382245 9 103923601 [T/G] NM_207299 PLPPR1 Silent rs1431463 9 103927286 [T/C] NM_207299 PLPPR1 Silent rs1367754 9 103930908 [T/C] NM_207299 PLPPR1 Silent rs10989419 9 103934113 [T/C] NM_207299 PLPPR1 Silent rs1346941 9 103937432 [A/G] NM_207299 PLPPR1 Silent rs9697078 9 103939007 [T/C] NM_207299 PLPPR1 Silent rs1864662 9 103946357 [A/G] NM_207299 PLPPR1 Silent rs7029916 9 103952270 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs2987735 9 103955515 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs12347855 9 103955777 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs1346942 9 103960732 [T/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs2567310 9 103964075 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs1431478 9 103964347 [A/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs12351067 9 103968906 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs17831028 9 103969339 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs10125791 9 103969740 [T/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs7047561 9 103969852 [A/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs2987742 9 103976442 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs4147116 9 103981628 [T/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs1367756 9 103993352 [T/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs4743454 9 104010913 [T/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs10819912 9 104012075 [T/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs750662 9 104013824 [A/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs1329071 9 104020751 [T/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs12237965 9 104021756 [T/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs2033394 9 104030793 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs10989461 9 104031777 [T/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs2567312 9 104032801 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs7034058 9 104033649 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs7035407 9 104033919 [A/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs1329077 9 104034955 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs10124153 9 104039202 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs10116399 9 104047608 [A/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs7040414 9 104059627 [T/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs10512279 9 104066880 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs1418002 9 104068262 [T/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs6479048 9 104068545 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs11790209 9 104072889 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs7869625 9 104075766 [T/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs7848242 9 104078061 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs12683393 9 104079119 [A/G] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs16920154 9 104079706 [T/C] NM_207299,NM_017753 PLPPR1,PLPPR1 EXON Synonymous_P291P,Synonymous_P291P rs17765053 9 104083253 [T/C] NM_207299,NM_017753 PLPPR1,PLPPR1 Silent,Silent rs7036576 9 104086584 [A/C] NM_207299,NM_017753 PLPPR1,PLPPR1 EXON Silent,Silent rs10989474 9 104089494 [A/G] rs11790501 9 104090736 [T/C] rs7040055 9 104091467 [A/G] rs12343738 9 104091917 [T/C] rs13284177 9 104093054 [A/G] rs16920200 9 104097889 [A/C] rs12375931 9 104101542 [T/C] rs2417250 9 104108650 [A/G] rs12683543 9 104108670 [T/C] rs16920222 9 104109389 [T/C] rs1417999 9 104110677 [A/G] rs16920236 9 104110968 [A/G] rs7043029 9 104123762 [T/G] NM_001127610,NM_001701 BAAT,BAAT EXON Silent,Silent rs16936057 9 104123815 [A/G] NM_001127610,NM_001701 BAAT,BAAT EXON Silent,Silent rs2229594 9 104124664 [T/C] NM_001127610,NM_001701 BAAT,BAAT EXON Silent,Silent rs4322060 9 104126523 [A/G] NM_001127610,NM_001701 BAAT,BAAT Silent,Silent rs1341762 9 104126546 [A/C] NM_001127610,NM_001701 BAAT,BAAT Silent,Silent rs1572983 9 104133628 [T/C] NM_001127610,NM_001701 BAAT,BAAT EXON Missense_R20Q,Missense_R20Q rs1891218 9 104134777 [T/C] NM_001127610,NM_001701 BAAT,BAAT Silent,Silent rs11496612 9 104142941 [A/C] NM_001127610,NM_001701 BAAT,BAAT Silent,Silent rs10118966 9 104152155 [T/C] rs16920291 9 104160338 [T/C] NM_019051 MRPL50 Silent rs2253258 9 104161154 [A/C] NM_001278240,NM_197977,NM_001278232,NM_003452,NR_103480,NM_001278231 ZNF189,ZNF189,ZNF189,ZNF189,ZNF189,ZNF189 EXON Silent,Silent,Silent,Silent,Silent,Silent rs10819926 9 104163789 [T/C] NM_001278240,NM_197977,NM_001278232,NM_003452,NR_103480,NM_001278231 ZNF189,ZNF189,ZNF189,ZNF189,ZNF189,ZNF189 Silent,Silent,Silent,Silent,Silent,Silent rs2777336 9 104164162 [A/C] NM_001278240,NM_197977,NM_001278232,NM_003452,NR_103480,NM_001278231 ZNF189,ZNF189,ZNF189,ZNF189,ZNF189,ZNF189 Silent,Silent,Silent,Silent,Silent,Silent rs17185855 9 104165360 [T/C] NM_001278240,NM_197977,NM_001278232,NM_003452,NR_103480,NM_001278231 ZNF189,ZNF189,ZNF189,ZNF189,ZNF189,ZNF189 Silent,Silent,Silent,Silent,Silent,Silent rs1929492 9 104166322 [A/G] NM_001278240,NM_197977,NM_001278232,NM_003452,NR_103480,NM_001278231 ZNF189,ZNF189,ZNF189,ZNF189,ZNF189,ZNF189 Silent,Silent,Silent,Silent,Silent,Silent rs2777345 9 104167718 [A/G] NM_001278240,NM_197977,NM_001278232,NM_003452,NR_103480,NM_001278231 ZNF189,ZNF189,ZNF189,ZNF189,ZNF189,ZNF189 Silent,Silent,Silent,Silent,Silent,Silent rs3739719 9 104169089 [A/G] NM_001278240,NM_197977,NM_001278232,NM_003452,NR_103480,NM_001278231 ZNF189,ZNF189,ZNF189,ZNF189,ZNF189,ZNF189 Silent,Silent,Silent,Silent,Silent,Silent rs17772514 9 104171856 [T/C] NM_001278240,NM_197977,NM_001278232,NM_003452,NR_103480,NM_001278231 ZNF189,ZNF189,ZNF189,ZNF189,ZNF189,ZNF189 EXON Silent,Synonymous_D560D,Synonymous_D587D,Synonymous_D602D,Silent,Synonymous_D588D rs546577 9 104172936 [A/C] NM_001278240,NM_197977,NM_001278232,NM_003452,NR_103480,NM_001278231 ZNF189,ZNF189,ZNF189,ZNF189,ZNF189,ZNF189 EXON Silent,Silent,Silent,Silent,Silent,Silent rs17772869 9 104183885 [T/G] NM_000035 ALDOB EXON Silent rs4577 9 104184022 [A/G] NM_000035 ALDOB EXON Silent VG09S31531 9 104184173 [A/G] NM_000035 ALDOB EXON Missense_A338V VG09S52451 9 104184181 [G/C] NM_000035 ALDOB EXON Missense_N335K rs550915 9 104191392 [A/C] NM_000035 ALDOB Silent rs533017 9 104194532 [T/C] NM_000035 ALDOB Silent rs717860 9 104201312 [A/G] rs479600 9 104202803 [T/C] rs13293668 9 104203482 [A/G] rs573816 9 104204614 [T/C] rs10760796 9 104210432 [T/C] rs7035564 9 104211810 [T/C] rs13297936 9 104213311 [A/G] rs7872599 9 104222989 [A/C] rs10989518 9 104223252 [T/C] rs4742814 9 104226808 [A/G] rs9409333 9 104228493 [A/G] rs1929495 9 104234907 [A/G] NR_121573,NR_121576,NR_121574,NR_121575 TMEM246-AS1,TMEM246-AS1,TMEM246-AS1,TMEM246-AS1 Silent,Silent,Silent,Silent rs1929494 9 104236774 [A/G] NR_121573,NR_121576,NR_121574,NR_121575,NM_032342,NM_001303107,NM_001303108 TMEM246-AS1,TMEM246-AS1,TMEM246-AS1,TMEM246-AS1,TMEM246,TMEM246,TMEM246 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13292501 9 104237055 [T/C] NR_121573,NR_121576,NR_121574,NR_121575,NM_032342,NM_001303107,NM_001303108 TMEM246-AS1,TMEM246-AS1,TMEM246-AS1,TMEM246-AS1,TMEM246,TMEM246,TMEM246 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2150738 9 104240708 [A/G] NR_121573,NR_121576,NR_121574,NR_121575,NM_032342,NM_001303107,NM_001303108 TMEM246-AS1,TMEM246-AS1,TMEM246-AS1,TMEM246-AS1,TMEM246,TMEM246,TMEM246 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10819943 9 104242808 [A/G] NR_121573,NR_121576,NR_121574,NR_121575,NM_032342,NM_001303107,NM_001303108 TMEM246-AS1,TMEM246-AS1,TMEM246-AS1,TMEM246-AS1,TMEM246,TMEM246,TMEM246 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2297355 9 104243757 [A/C] NR_121573,NR_121576,NR_121574,NR_121575,NM_032342,NM_001303107,NM_001303108 TMEM246-AS1,TMEM246-AS1,TMEM246-AS1,TMEM246-AS1,TMEM246,TMEM246,TMEM246 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1929482 9 104246779 [T/C] NM_032342,NM_001303107,NM_001303108 TMEM246,TMEM246,TMEM246 Silent,Silent,Silent rs7867496 9 104253681 [A/G] rs7045287 9 104262460 [A/G] rs1929478 9 104263799 [T/C] rs1929496 9 104266953 [A/C] rs989901 9 104267265 [A/G] rs16920447 9 104268342 [A/G] rs13290720 9 104269009 [T/C] rs1323419 9 104270257 [T/C] rs1407869 9 104273901 [A/G] rs1407868 9 104274944 [A/G] rs4743466 9 104275622 [A/G] rs12684621 9 104277937 [T/G] rs11790317 9 104279275 [A/G] rs7023854 9 104291812 [T/C] rs10989551 9 104292666 [T/C] rs3818337 9 104295764 [T/G] rs16920477 9 104302625 [A/G] NM_019592 RNF20 EXON Synonymous_L90L rs7037267 9 104302958 [T/C] NM_019592 RNF20 Silent rs12684584 9 104307633 [T/C] NM_019592 RNF20 Silent rs12343288 9 104308365 [A/G] NM_019592 RNF20 Silent rs2273976 9 104309445 [T/C] NM_019592 RNF20 EXON Synonymous_Y307Y rs16920483 9 104315255 [A/G] NM_019592 RNF20 Silent rs10989553 9 104315931 [T/G] NM_019592 RNF20 Silent rs10521057 9 104324545 [A/G] NM_019592 RNF20 EXON Synonymous_P923P rs1983812 9 104333043 [T/C] NM_133445 GRIN3A EXON Silent rs10512282 9 104334333 [T/G] NM_133445 GRIN3A EXON Silent rs3824473 9 104334777 [T/C] NM_133445 GRIN3A EXON Silent rs3739722 9 104335682 [T/C] NM_133445 GRIN3A EXON Missense_R1041Q rs7859863 9 104337744 [A/G] NM_133445 GRIN3A Silent rs11791337 9 104338416 [T/C] NM_133445 GRIN3A Silent rs10081707 9 104338456 [A/G] NM_133445 GRIN3A Silent rs10123961 9 104343719 [T/G] NM_133445 GRIN3A Silent rs7873495 9 104350424 [T/C] NM_133445 GRIN3A Silent rs4743473 9 104352574 [A/G] NM_133445 GRIN3A Silent rs1407877 9 104355455 [T/C] NM_133445,NM_147180 GRIN3A,PPP3R2 EXON Silent,Silent rs3739724 9 104356439 [T/C] NM_133445,NM_147180 GRIN3A,PPP3R2 EXON Silent,Silent rs1323433 9 104358072 [T/C] NM_133445 GRIN3A Silent rs7858998 9 104359035 [T/C] NM_133445 GRIN3A Silent rs6479056 9 104359261 [A/G] NM_133445 GRIN3A Silent rs1323432 9 104362937 [A/G] NM_133445 GRIN3A Silent rs9969726 9 104368397 [T/C] NM_133445 GRIN3A Silent rs1885979 9 104371037 [T/C] NM_133445 GRIN3A Silent rs942141 9 104371736 [T/G] NM_133445 GRIN3A Silent rs9299346 9 104373787 [A/G] NM_133445 GRIN3A Silent rs7875712 9 104374738 [A/G] NM_133445 GRIN3A Silent rs9792648 9 104376601 [A/G] NM_133445 GRIN3A Silent rs10121600 9 104378003 [T/C] NM_133445 GRIN3A Silent rs10124802 9 104378328 [A/G] NM_133445 GRIN3A Silent rs10117679 9 104378479 [T/C] NM_133445 GRIN3A Silent rs10989563 9 104385711 [T/C] NM_133445 GRIN3A EXON Missense_D835N rs10989565 9 104385800 [A/G] NM_133445 GRIN3A Silent rs16920538 9 104387806 [T/C] NM_133445 GRIN3A Silent rs1570514 9 104388863 [T/G] NM_133445 GRIN3A Silent rs2417290 9 104390195 [A/C] NM_133445 GRIN3A Silent rs1004362 9 104390423 [T/C] NM_133445 GRIN3A Silent rs13292935 9 104392143 [T/C] NM_133445 GRIN3A Silent rs7027241 9 104393166 [T/C] NM_133445 GRIN3A Silent rs13289614 9 104394629 [A/C] NM_133445 GRIN3A Silent rs10989574 9 104399139 [T/C] NM_133445 GRIN3A Silent rs7856074 9 104404261 [A/G] NM_133445 GRIN3A Silent rs12342601 9 104409985 [T/C] NM_133445 GRIN3A Silent rs13296742 9 104413034 [T/C] NM_133445 GRIN3A Silent rs1924032 9 104417812 [T/C] NM_133445 GRIN3A Silent rs12685672 9 104420176 [T/C] NM_133445 GRIN3A Silent rs16920640 9 104425362 [A/G] NM_133445 GRIN3A Silent rs1323416 9 104425619 [T/C] NM_133445 GRIN3A Silent rs942142 9 104432873 [T/G] NM_133445 GRIN3A EXON Synonymous_A607A rs10512285 9 104433034 [A/G] NM_133445 GRIN3A EXON Synonymous_L554L rs13284303 9 104433347 [A/G] NM_133445 GRIN3A EXON Synonymous_I449I rs7469637 9 104437373 [T/G] NM_133445 GRIN3A Silent rs1323423 9 104439370 [T/C] NM_133445 GRIN3A Silent rs2506352 9 104443319 [T/C] NM_133445 GRIN3A Silent rs2485531 9 104445493 [A/C] NM_133445 GRIN3A Silent rs2506354 9 104449063 [T/C] NM_133445 GRIN3A EXON Synonymous_G373G rs10989591 9 104449098 [T/C] NM_133445 GRIN3A EXON Missense_V362M rs2485522 9 104454025 [T/C] NM_133445 GRIN3A Silent rs1415645 9 104459296 [A/G] NM_133445 GRIN3A Silent rs2485530 9 104473886 [T/C] NM_133445 GRIN3A Silent rs7043519 9 104474060 [A/G] NM_133445 GRIN3A Silent rs945870 9 104475496 [A/G] NM_133445 GRIN3A Silent rs10124157 9 104476819 [T/C] NM_133445 GRIN3A Silent rs7863180 9 104482845 [T/C] NM_133445 GRIN3A Silent rs2050641 9 104489367 [T/C] NM_133445 GRIN3A Silent rs7041051 9 104492591 [A/G] NM_133445 GRIN3A Silent rs1415644 9 104493766 [A/G] NM_133445 GRIN3A Silent rs4278209 9 104495190 [T/C] NM_133445 GRIN3A Silent rs7848096 9 104497569 [T/G] NM_133445 GRIN3A Silent rs12340365 9 104498664 [T/C] NM_133445 GRIN3A Silent rs2900317 9 104504756 [A/G] rs11788625 9 104514018 [T/G] rs10819985 9 104515222 [A/G] rs7864316 9 104521883 [A/G] rs4743486 9 104522208 [A/G] rs1415652 9 104525970 [A/G] rs7874128 9 104534755 [A/C] rs10819990 9 104535125 [A/G] rs11791821 9 104543022 [T/C] rs1885387 9 104550554 [A/G] rs4743489 9 104550927 [A/G] rs4742825 9 104552015 [A/G] rs16920763 9 104553765 [T/C] rs10819994 9 104554756 [A/G] rs1337706 9 104555316 [T/C] rs10989626 9 104557532 [T/G] rs10739815 9 104563211 [T/C] rs1184818 9 104563334 [A/G] rs7857093 9 104567544 [T/C] rs6479065 9 104569036 [T/G] rs7034450 9 104569198 [A/G] rs2417297 9 104570604 [A/G] rs2013563 9 104576030 [T/C] rs7873360 9 104584465 [A/G] rs10989636 9 104584492 [T/C] rs7873471 9 104584538 [T/G] rs16936082 9 104588622 [A/C] rs9409348 9 104594799 [T/C] rs1337687 9 104595324 [A/C] rs1022749 9 104595776 [T/C] rs2786717 9 104596969 [T/G] rs2181040 9 104597349 [A/G] rs7031164 9 104605562 [T/C] rs10989657 9 104613466 [T/C] rs10739816 9 104616470 [T/C] rs10820002 9 104619833 [T/C] rs7868836 9 104619905 [T/C] rs10989661 9 104622868 [A/G] rs12552818 9 104623359 [A/G] rs2181038 9 104623443 [A/C] rs17792220 9 104624002 [A/G] rs16920898 9 104625704 [A/G] rs7047881 9 104626607 [A/G] rs1012203 9 104626708 [A/G] rs1002665 9 104630136 [T/C] rs10989672 9 104637950 [T/C] rs10989674 9 104638067 [T/C] rs12236471 9 104640499 [T/G] rs9299352 9 104642966 [T/C] rs12347415 9 104644870 [T/C] rs1555461 9 104650296 [T/C] rs1743300 9 104652159 [A/G] rs11793523 9 104655954 [T/C] rs823922 9 104657274 [T/G] rs823921 9 104657657 [A/G] rs823920 9 104662585 [A/G] rs823915 9 104665751 [T/C] rs10820006 9 104666077 [A/G] rs1165806 9 104668084 [A/G] rs2224531 9 104671992 [T/G] rs10989691 9 104674217 [T/C] rs2795379 9 104675628 [T/C] rs2756919 9 104676140 [T/C] rs16920991 9 104678175 [A/G] rs11794511 9 104680797 [A/G] rs12343857 9 104681509 [T/C] rs10820007 9 104682988 [A/G] rs7042948 9 104686402 [T/G] rs7867903 9 104690092 [T/C] rs1418236 9 104705253 [A/C] rs10820015 9 104705331 [T/C] rs1418232 9 104706100 [T/G] rs3012580 9 104707762 [A/C] rs7041807 9 104708430 [A/G] rs1361665 9 104708457 [T/G] rs2995211 9 104709020 [A/G] rs10989718 9 104713471 [A/C] rs1007468 9 104728905 [T/C] rs7850788 9 104730823 [T/G] rs10820019 9 104734570 [T/G] rs12338709 9 104742729 [T/C] rs4574904 9 104747133 [T/C] rs3012585 9 104752620 [A/G] rs4743514 9 104759737 [A/G] rs10124808 9 104759787 [A/G] rs1418243 9 104760894 [A/G] rs17206790 9 104765534 [A/G] rs1418247 9 104765867 [T/G] rs2995190 9 104766075 [T/C] rs10820027 9 104768230 [A/G] rs10989766 9 104771134 [A/G] rs2995192 9 104780164 [T/G] rs1935376 9 104781700 [T/C] rs2995195 9 104782096 [A/C] rs1935383 9 104789573 [T/C] rs1342112 9 104794273 [T/C] rs7041890 9 104795624 [T/C] rs1342119 9 104799619 [A/G] rs10118278 9 104801485 [A/G] rs2442672 9 104802798 [T/G] rs12551744 9 104802828 [T/C] rs1449655 9 104808575 [A/G] rs2839950 9 104811726 [A/G] rs10820042 9 104813342 [A/G] rs10820043 9 104813822 [T/C] rs16921199 9 104819532 [T/C] rs1935373 9 104819955 [A/G] rs320296 9 104830117 [T/G] rs320294 9 104830919 [A/G] rs10820046 9 104834632 [A/G] rs1449653 9 104834950 [A/G] rs320291 9 104836267 [T/C] rs320290 9 104837536 [T/G] rs17208989 9 104840519 [A/G] rs320286 9 104841979 [T/C] rs11790712 9 104842043 [T/C] rs320284 9 104843374 [T/C] rs16921254 9 104845283 [T/C] rs10820053 9 104852073 [A/G] rs320261 9 104863013 [A/G] rs10760840 9 104863180 [A/G] rs1375707 9 104874984 [A/C] rs12377834 9 104876584 [T/C] rs7852686 9 104878135 [A/G] rs10448296 9 104879699 [A/C] rs1962673 9 104882097 [T/C] rs10820069 9 104883836 [A/G] rs1932152 9 104902874 [A/G] rs583861 9 104904232 [T/C] rs10760846 9 104904454 [T/C] rs320245 9 104906690 [A/G] rs10118990 9 104926878 [T/C] rs10989885 9 104939023 [T/C] rs10820084 9 104940829 [T/C] rs320201 9 104941304 [T/C] rs10117916 9 104942186 [A/G] rs320202 9 104943139 [T/G] rs320203 9 104943226 [A/C] rs320204 9 104943443 [T/C] rs320205 9 104943675 [T/C] rs7028042 9 104944497 [A/G] rs320213 9 104945543 [A/G] rs16921296 9 104945929 [A/G] rs320214 9 104946242 [A/G] rs320215 9 104946268 [T/C] rs9918994 9 104947395 [T/C] rs10820085 9 104949975 [T/G] rs10760848 9 104950176 [T/C] rs10739833 9 104950962 [A/G] rs10122572 9 104951839 [T/C] rs10760851 9 104954524 [T/G] rs7029138 9 104955990 [T/C] rs12336913 9 104958057 [A/G] rs10820088 9 104959452 [T/C] rs1932169 9 104960302 [A/C] rs10114523 9 104962110 [T/C] rs16921360 9 104963105 [A/G] rs10119241 9 104965221 [A/G] rs7857876 9 104965863 [A/C] rs16921368 9 104971300 [A/C] rs7040955 9 104971320 [T/C] rs1932165 9 104973626 [A/G] rs1932164 9 104973771 [A/G] rs6479093 9 104986223 [A/G] rs10989904 9 104990394 [T/G] rs7854132 9 104991230 [A/C] rs12336157 9 104991804 [T/G] rs9644962 9 104992089 [T/C] rs7861666 9 104994909 [A/G] rs1115733 9 104997660 [A/G] rs7869148 9 105000062 [A/C] rs1932158 9 105009468 [A/G] rs10989911 9 105009828 [A/C] rs10989913 9 105012777 [A/C] rs2067538 9 105012816 [A/C] rs12351019 9 105014067 [T/C] rs10820103 9 105014373 [A/G] rs912211 9 105016960 [A/G] rs10760858 9 105019080 [T/C] rs1923983 9 105021136 [A/G] rs10739836 9 105022332 [T/C] rs6479096 9 105024768 [T/C] rs12006153 9 105025138 [T/C] rs7031871 9 105026764 [T/G] rs10118114 9 105029381 [A/G] rs7036669 9 105034238 [A/G] rs1923987 9 105035936 [A/C] rs13296598 9 105036478 [A/G] rs7466994 9 105037839 [T/G] rs959065 9 105041206 [A/G] rs959066 9 105041263 [A/G] rs959068 9 105041375 [T/G] rs1040980 9 105041756 [A/G] rs10989950 9 105042090 [A/G] rs16921474 9 105042198 [A/G] rs10820120 9 105043748 [T/C] rs10820123 9 105045726 [A/C] rs7865273 9 105046060 [T/G] rs4376547 9 105050664 [T/C] rs1924004 9 105055586 [A/G] rs1924005 9 105056347 [T/C] rs2417335 9 105058421 [T/C] rs9409365 9 105058753 [A/G] rs10733718 9 105058946 [T/G] rs16921494 9 105059601 [A/G] rs10989973 9 105060163 [T/C] rs2417336 9 105063781 [T/G] rs1022838 9 105074656 [T/C] rs12005744 9 105077400 [A/G] rs4742843 9 105077531 [A/G] rs1543533 9 105077543 [T/C] rs4308791 9 105079080 [A/G] rs10990004 9 105086690 [A/C] rs9409373 9 105090815 [A/G] rs10114491 9 105093304 [A/G] rs9409038 9 105094335 [C/G] rs1924024 9 105096394 [A/G] rs1924026 9 105097068 [A/G] rs1425279 9 105108011 [A/G] rs9409041 9 105108224 [T/C] rs1477530 9 105111298 [T/G] rs7038470 9 105117488 [A/G] rs1425280 9 105120779 [T/C] rs10441769 9 105122350 [T/G] rs2417361 9 105135141 [A/G] rs9299361 9 105137537 [T/C] rs1364820 9 105143745 [A/G] rs1923975 9 105144688 [T/C] rs12005061 9 105146406 [T/G] rs10990059 9 105146568 [A/G] rs10760887 9 105146883 [A/G] rs6479112 9 105167688 [T/C] rs10733724 9 105172992 [T/C] rs10760891 9 105173098 [A/G] rs10119950 9 105175187 [A/G] rs10820177 9 105178145 [T/C] rs2031200 9 105186697 [T/C] rs10820183 9 105197759 [T/G] rs16921686 9 105202644 [T/G] rs7847867 9 105204612 [A/G] rs4410962 9 105207670 [T/C] rs7026565 9 105208847 [T/C] rs10990103 9 105214028 [T/C] rs10990106 9 105216600 [A/C] rs10760894 9 105219505 [T/C] rs10990123 9 105239171 [T/C] rs1946334 9 105246175 [T/C] rs7849848 9 105259717 [T/C] rs7868372 9 105266273 [A/C] rs7029589 9 105279735 [T/G] rs4514038 9 105292037 [A/G] NR_103830 LINC00587 Silent rs10115055 9 105298240 [T/C] NR_103830 LINC00587 Silent rs10990169 9 105305028 [A/G] NR_103830 LINC00587 Silent rs16921790 9 105306425 [T/C] NR_103830 LINC00587 Silent rs12684463 9 105309339 [T/C] NR_103830 LINC00587 Silent rs4521822 9 105315604 [T/G] NR_103830 LINC00587 Silent rs10820203 9 105323892 [A/G] NR_103830 LINC00587 Silent rs1412799 9 105323932 [A/G] NR_103830 LINC00587 Silent rs7846871 9 105325292 [T/C] NR_103830 LINC00587 Silent rs10990190 9 105329760 [T/C] NR_103830 LINC00587 Silent rs10760899 9 105342266 [A/G] NR_103830 LINC00587 Silent rs4743564 9 105347447 [A/C] NR_103830 LINC00587 Silent rs1332984 9 105350958 [A/C] NR_103830 LINC00587 Silent rs16921837 9 105353221 [A/G] NR_103830 LINC00587 Silent rs16921840 9 105355578 [T/C] NR_103830 LINC00587 Silent rs7875594 9 105371812 [A/G] NR_103830 LINC00587 Silent rs1332980 9 105376158 [A/G] NR_103830 LINC00587 Silent rs10739849 9 105376813 [T/C] NR_103830 LINC00587 Silent rs1115634 9 105390418 [A/G] NR_103830 LINC00587 Silent rs10820213 9 105395352 [T/C] NR_103830 LINC00587 Silent rs7046513 9 105399431 [T/C] NR_103830 LINC00587 Silent rs16926142 9 105400552 [T/C] NR_103830 LINC00587 Silent rs1332999 9 105408515 [T/C] NR_103830 LINC00587 Silent rs7865059 9 105412545 [T/C] NR_103830 LINC00587 Silent rs4743569 9 105414408 [A/G] NR_103830 LINC00587 Silent rs13283389 9 105414477 [A/G] NR_103830 LINC00587 Silent rs12553605 9 105420968 [T/G] rs12553989 9 105422136 [A/G] rs12553388 9 105422608 [T/C] rs10760900 9 105424988 [T/G] rs1332988 9 105425207 [T/G] rs4294244 9 105426977 [A/G] rs12686229 9 105430482 [A/G] rs4313213 9 105431576 [T/C] rs2210533 9 105442117 [A/G] rs10990238 9 105444722 [A/C] rs7866103 9 105445184 [T/C] rs10820230 9 105446609 [A/G] rs1556503 9 105454102 [A/G] rs10820241 9 105464554 [T/G] rs10820244 9 105465785 [T/C] rs4743571 9 105468208 [T/C] rs7869982 9 105474366 [A/G] rs7870093 9 105474384 [A/G] rs1576949 9 105474758 [A/G] rs16922059 9 105476561 [A/G] rs10990259 9 105482137 [T/G] rs1602690 9 105485375 [T/C] rs10820255 9 105489249 [T/C] rs7870366 9 105495207 [A/G] rs1492594 9 105495671 [T/C] rs985453 9 105496890 [T/C] rs10990268 9 105502498 [T/C] rs1492595 9 105502882 [A/G] rs1492596 9 105503137 [A/G] rs10990270 9 105503295 [T/C] rs1388919 9 105503706 [T/C] rs4743577 9 105507920 [A/G] rs4354369 9 105512975 [T/C] rs10820273 9 105518491 [A/G] rs10990300 9 105521808 [T/C] rs1580650 9 105523821 [T/C] rs7469903 9 105524913 [A/G] rs7858600 9 105526362 [A/G] rs7047925 9 105526510 [A/G] rs10820274 9 105527511 [T/G] rs10990302 9 105529745 [T/C] rs4743578 9 105534377 [A/G] rs1388920 9 105541245 [A/G] rs12237372 9 105541307 [A/G] rs1492602 9 105542534 [A/G] rs4743582 9 105545039 [A/G] rs994864 9 105545483 [T/C] rs994865 9 105545528 [T/C] rs1388921 9 105545596 [A/G] rs10820282 9 105545781 [A/G] rs7854657 9 105546074 [A/G] rs10990317 9 105546493 [T/G] rs12551330 9 105547307 [T/C] rs7869941 9 105548952 [T/C] rs12376672 9 105563495 [T/C] rs10217639 9 105566691 [T/C] rs7848024 9 105573037 [A/G] rs13294991 9 105583926 [A/C] rs1552766 9 105585487 [A/G] rs7866606 9 105585894 [T/G] rs7033449 9 105587136 [T/C] rs2812594 9 105591790 [A/G] rs10990353 9 105593380 [A/G] rs1492598 9 105595173 [A/G] rs10512305 9 105595627 [A/G] rs16922214 9 105596754 [A/G] rs4742861 9 105597227 [A/G] rs843270 9 105603760 [T/G] rs10990359 9 105608043 [A/G] rs10990361 9 105619674 [T/G] rs2639345 9 105620884 [T/C] rs843283 9 105623942 [A/C] rs1352979 9 105632182 [T/C] rs2220706 9 105633963 [T/C] rs843275 9 105634309 [T/C] rs843272 9 105635106 [T/C] rs1492600 9 105639770 [T/G] rs10990362 9 105644879 [T/C] rs11496631 9 105675653 [T/C] rs10990381 9 105685265 [A/G] rs10990384 9 105695150 [A/G] rs1935861 9 105700390 [T/C] rs10124970 9 105704669 [T/C] rs2067711 9 105706469 [T/G] rs10820319 9 105707984 [T/G] rs12005200 9 105708946 [T/C] rs10820320 9 105711552 [A/G] rs4409450 9 105725193 [A/G] rs12000047 9 105728627 [T/C] rs2211427 9 105733795 [A/G] rs10990402 9 105734158 [T/G] rs10990405 9 105740221 [T/C] rs1934995 9 105746701 [A/G] rs10124146 9 105753694 [T/C] rs10990412 9 105754930 [T/C] rs1341204 9 105755977 [T/C] rs12156626 9 105758477 [A/C] NM_001340 CYLC2 Silent rs10990416 9 105763301 [A/G] NM_001340 CYLC2 Silent rs10760932 9 105764116 [T/C] NM_001340 CYLC2 Silent rs10990423 9 105766479 [A/G] NM_001340 CYLC2 Silent rs2298052 9 105767702 [T/C] NM_001340 CYLC2 EXON Synonymous_D263D rs10119488 9 105768503 [T/C] NM_001340 CYLC2 EXON Silent rs10739862 9 105770875 [T/C] NM_001340 CYLC2 Silent rs1107540 9 105771136 [A/G] NM_001340 CYLC2 Silent rs2211279 9 105772065 [A/C] NM_001340 CYLC2 Silent rs7856837 9 105778790 [A/G] NM_001340 CYLC2 Silent rs13291989 9 105780618 [A/G] NM_001340 CYLC2 EXON Silent rs1341207 9 105785533 [A/G] rs10121525 9 105788456 [A/G] rs10512309 9 105789727 [A/G] rs947184 9 105790119 [A/G] rs11788777 9 105790199 [A/C] rs10990460 9 105794662 [T/C] rs1578450 9 105795970 [A/G] rs10820351 9 105797832 [T/G] rs1341211 9 105800243 [A/G] rs7038696 9 105803672 [T/C] rs1448594 9 105812289 [T/C] rs716450 9 105815502 [A/G] rs10990481 9 105815878 [A/G] rs1099151 9 105822396 [A/G] rs12377905 9 105827744 [A/C] rs843192 9 105827815 [T/C] rs12347896 9 105832538 [A/G] rs843167 9 105837587 [T/C] rs10990512 9 105839544 [A/C] rs843166 9 105842362 [T/C] rs843162 9 105844979 [A/C] rs10990523 9 105846496 [T/C] rs843159 9 105847351 [T/C] rs843158 9 105847555 [T/C] rs10990524 9 105848723 [A/G] rs10123704 9 105850270 [A/G] rs1375209 9 105853222 [A/G] rs10990533 9 105858882 [A/C] rs1417702 9 105864747 [A/C] rs6479155 9 105868652 [T/C] rs7048164 9 105879111 [T/C] rs1597210 9 105881438 [A/C] rs10990553 9 105882459 [A/C] rs7873512 9 105883836 [T/G] rs843180 9 105884526 [T/C] rs10990559 9 105893479 [A/G] rs10120196 9 105900043 [T/C] rs4743624 9 105900413 [T/C] rs4743626 9 105904199 [A/G] NR_121578 LINC01492 EXON Silent rs2218687 9 105920416 [A/G] NR_121578 LINC01492 Silent rs12378919 9 105923585 [T/G] NR_121578 LINC01492 Silent rs1839166 9 105937834 [A/G] NR_121578 LINC01492 Silent rs10990596 9 105939715 [T/C] NR_121578 LINC01492 Silent rs1448579 9 105940438 [T/G] NR_121578 LINC01492 Silent rs10990599 9 105942389 [A/G] NR_121578 LINC01492 Silent rs4742875 9 105942403 [A/G] NR_121578 LINC01492 Silent rs10820387 9 105946455 [A/C] NR_121578 LINC01492 Silent rs10990603 9 105947343 [A/C] NR_121578 LINC01492 Silent rs10739871 9 105951481 [A/C] NR_121578 LINC01492 Silent rs7047105 9 105951980 [A/G] NR_121578 LINC01492 Silent rs12339905 9 105955511 [T/C] NR_121578 LINC01492 Silent rs10990617 9 105964224 [T/C] NR_121578 LINC01492 Silent rs11789118 9 105964658 [T/C] NR_121578 LINC01492 Silent rs10990619 9 105965663 [A/G] NR_121578 LINC01492 Silent rs16922610 9 105965683 [A/C] NR_121578 LINC01492 Silent rs10990625 9 105969051 [T/C] NR_121578 LINC01492 Silent rs1823279 9 105969101 [A/G] NR_121578 LINC01492 Silent rs1823281 9 105969217 [A/G] NR_121578 LINC01492 Silent rs10990626 9 105971199 [T/C] NR_121578 LINC01492 Silent rs7850677 9 105971237 [A/G] NR_121578 LINC01492 Silent rs10820391 9 105971829 [A/G] NR_121578 LINC01492 Silent rs2084468 9 105971838 [A/C] NR_121578 LINC01492 Silent rs4743634 9 105977018 [T/C] NR_121578 LINC01492 Silent rs17775713 9 105977028 [T/C] NR_121578 LINC01492 Silent rs7044631 9 105983538 [A/G] NR_121578 LINC01492 Silent rs1448577 9 105983780 [T/C] NR_121578 LINC01492 Silent rs10990632 9 105983864 [T/C] NR_121578 LINC01492 Silent rs10739874 9 105991203 [T/C] NR_121578 LINC01492 Silent rs10760966 9 105993121 [A/G] NR_121578 LINC01492 Silent rs1176191 9 105993267 [T/C] NR_121578 LINC01492 Silent rs7865219 9 105999196 [T/C] NR_121578 LINC01492 Silent rs16922639 9 106004562 [T/C] NR_121578 LINC01492 Silent rs10990645 9 106005044 [T/C] NR_121578 LINC01492 Silent rs10820403 9 106006075 [A/G] NR_121578 LINC01492 Silent rs1456476 9 106009535 [T/C] NR_121578 LINC01492 Silent rs7033431 9 106013174 [T/C] NR_121578 LINC01492 Silent rs167334 9 106015010 [T/C] NR_121578 LINC01492 Silent rs10990654 9 106017371 [A/G] NR_121578 LINC01492 Silent rs303545 9 106021388 [A/G] NR_121578 LINC01492 Silent rs16922670 9 106024220 [T/C] NR_121578 LINC01492 Silent rs303585 9 106034122 [T/C] NR_121578 LINC01492 Silent rs4295718 9 106038803 [T/C] NR_121578 LINC01492 Silent rs1124647 9 106046072 [T/C] NR_121578 LINC01492 Silent rs12337792 9 106052433 [T/G] NR_121578 LINC01492 Silent rs12004858 9 106053927 [T/C] NR_121578 LINC01492 Silent rs303615 9 106060322 [A/G] NR_121578 LINC01492 Silent rs4743641 9 106067533 [T/C] NR_121578 LINC01492 Silent rs1378974 9 106068965 [T/C] NR_121578 LINC01492 Silent rs445722 9 106082463 [T/C] NR_121578 LINC01492 EXON Silent rs16922767 9 106082492 [T/C] NR_121578 LINC01492 Silent rs370386 9 106083827 [A/G] NR_121578 LINC01492 Silent rs423433 9 106087206 [A/C] NR_121578 LINC01492 Silent rs373637 9 106087352 [T/C] rs379786 9 106091787 [A/G] rs450441 9 106093936 [A/G] rs414964 9 106098966 [A/G] rs12002497 9 106100469 [T/C] rs16922813 9 106101057 [T/C] rs7037370 9 106101691 [T/C] rs303575 9 106104878 [A/G] rs11999327 9 106106116 [T/G] rs1904928 9 106120670 [A/G] rs303596 9 106122565 [A/G] rs303598 9 106123271 [A/G] rs303603 9 106124641 [A/G] rs10820413 9 106126869 [T/C] rs16922872 9 106137424 [T/C] rs303635 9 106148215 [T/G] rs16922886 9 106153263 [T/C] rs303620 9 106163708 [T/C] rs9695167 9 106169268 [A/C] rs303543 9 106173210 [T/G] rs303542 9 106173793 [A/G] rs6479168 9 106177362 [T/C] rs6479169 9 106181050 [T/C] rs16922895 9 106195084 [T/C] rs10990701 9 106205224 [A/G] rs12682841 9 106205827 [A/G] rs12683176 9 106207271 [A/G] rs1936739 9 106235615 [A/C] rs1415686 9 106236224 [A/C] rs17790711 9 106238925 [T/C] rs16922936 9 106240743 [T/C] rs10820423 9 106242831 [A/G] rs12379035 9 106243701 [A/G] rs12351109 9 106248670 [A/G] rs10820441 9 106261364 [A/G] rs840250 9 106268589 [A/C] rs13285576 9 106268919 [A/G] rs10820445 9 106270798 [A/G] rs1703481 9 106283105 [A/G] rs10760969 9 106287146 [A/G] rs2202828 9 106289427 [T/C] rs10760970 9 106295428 [T/C] rs10990763 9 106302762 [T/C] rs840256 9 106306038 [T/G] rs840255 9 106306486 [T/G] rs840241 9 106311685 [A/G] rs2786798 9 106326245 [T/C] rs1995789 9 106327061 [T/G] rs10820459 9 106331688 [T/C] rs1509040 9 106333748 [A/G] rs1577902 9 106335903 [T/C] rs1577905 9 106337200 [A/C] rs4540458 9 106344556 [A/G] rs7871238 9 106345031 [T/C] rs7865138 9 106348522 [T/G] rs7048428 9 106359311 [A/G] rs10990824 9 106375480 [A/G] rs10990825 9 106375915 [A/G] rs10990826 9 106375973 [A/G] rs10990837 9 106381192 [T/C] rs10990840 9 106385442 [A/G] rs10990842 9 106385994 [A/G] rs10760978 9 106386149 [T/G] rs7875662 9 106387226 [A/G] rs2221127 9 106391797 [T/G] rs10820503 9 106396321 [T/C] rs2055749 9 106399281 [A/C] rs11794668 9 106400878 [A/G] rs11788173 9 106407456 [A/C] rs7867943 9 106409952 [A/C] rs10990869 9 106417844 [T/C] rs11793044 9 106422027 [T/G] rs10760980 9 106423464 [A/G] rs10990877 9 106424148 [A/C] rs7860970 9 106441872 [T/C] rs17799628 9 106442996 [T/C] rs10820531 9 106459537 [A/C] rs368956 9 106459868 [A/G] rs412741 9 106460892 [A/G] rs970603 9 106464499 [A/G] rs7046913 9 106468046 [T/C] rs449475 9 106470714 [T/C] rs403258 9 106477496 [A/G] rs10990914 9 106481839 [T/C] rs4743664 9 106483432 [T/C] rs4436177 9 106487753 [T/G] rs433341 9 106493088 [A/G] rs455178 9 106498091 [A/C] rs1659546 9 106505693 [A/G] rs428072 9 106512148 [T/C] rs10990941 9 106530763 [A/G] rs10739877 9 106531629 [T/C] rs10739878 9 106535762 [A/G] rs16923311 9 106545276 [T/C] rs16923314 9 106546851 [T/C] rs16923317 9 106547099 [A/G] rs7864801 9 106554028 [A/G] rs16923334 9 106556113 [T/C] rs6479189 9 106565689 [T/C] rs1439186 9 106573399 [T/C] rs1439190 9 106581950 [A/G] rs1371169 9 106584972 [T/C] rs1439189 9 106585651 [A/G] rs7037107 9 106593860 [T/C] rs17802452 9 106600479 [T/C] rs12555838 9 106601859 [T/C] rs10512319 9 106604077 [A/G] rs7046385 9 106604233 [T/C] rs13298450 9 106610918 [A/G] rs3930054 9 106611898 [A/C] rs16923415 9 106618967 [T/C] rs7864255 9 106631068 [T/C] rs7036142 9 106631091 [A/G] rs10820559 9 106637033 [T/C] rs7037581 9 106649139 [A/G] rs920810 9 106659562 [T/C] rs920809 9 106659817 [A/C] rs9657690 9 106659985 [A/G] rs716533 9 106660496 [A/C] rs10990985 9 106665541 [T/C] rs1348451 9 106667534 [A/G] rs7025066 9 106674242 [A/G] rs7045335 9 106674435 [T/C] rs7042328 9 106674531 [A/G] rs10990991 9 106674850 [T/C] rs718856 9 106675290 [T/C] rs10760997 9 106681686 [T/C] rs10217653 9 106693503 [T/C] rs10820566 9 106694482 [A/G] rs4743670 9 106703809 [T/C] rs2197295 9 106707757 [A/C] rs10820576 9 106714767 [A/C] rs7042666 9 106715594 [T/C] rs747029 9 106719165 [T/G] rs10820583 9 106720681 [T/C] rs10512321 9 106721804 [T/C] rs10820588 9 106722204 [T/G] rs2218384 9 106723148 [T/C] rs7874564 9 106726855 [A/G] rs1348455 9 106730859 [T/G] rs10739883 9 106733485 [A/G] rs16923598 9 106736021 [A/G] rs1443843 9 106741410 [T/C] rs1822539 9 106741855 [T/C] rs535966 9 106742792 [A/G] rs10991022 9 106744641 [T/C] rs10991023 9 106745051 [A/G] rs13301641 9 106761243 [T/C] rs617010 9 106761956 [T/G] rs531262 9 106764390 [A/G] rs7857804 9 106765319 [T/C] rs687586 9 106769158 [A/C] rs1867347 9 106772759 [A/G] rs10991038 9 106780898 [A/G] rs628345 9 106786496 [A/G] rs630103 9 106786864 [A/G] rs868619 9 106791364 [T/G] rs10991043 9 106797388 [T/C] rs12115654 9 106798942 [T/G] rs1411097 9 106801089 [T/C] rs12345652 9 106801187 [T/C] rs10991055 9 106813132 [T/C] rs1411101 9 106813465 [A/G] rs4742899 9 106822968 [A/G] rs12551885 9 106828404 [T/G] rs10991090 9 106835052 [A/G] rs10991099 9 106850457 [A/G] NR_121580 SMC2-AS1 Silent rs1411105 9 106850787 [A/G] NR_121580 SMC2-AS1 Silent rs1411103 9 106854958 [T/C] rs4742901 9 106856043 [T/C] rs3818626 9 106856633 [T/C] NM_001042551,NM_001265602,NM_006444 SMC2,SMC2,SMC2 EXON Silent,Silent,Silent rs4743687 9 106856910 [T/C] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 EXON Silent,Silent,Silent,Silent rs4742906 9 106857078 [A/G] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 EXON Silent,Silent,Silent,Silent rs12236470 9 106858851 [T/G] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 Silent,Silent,Silent,Silent rs7028408 9 106859811 [A/G] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 Silent,Silent,Silent,Silent rs10991107 9 106860969 [T/C] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 Silent,Silent,Silent,Silent rs10991109 9 106865027 [A/C] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 Silent,Silent,Silent,Silent rs7860378 9 106873378 [A/C] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 Silent,Silent,Silent,Silent rs10820603 9 106877939 [A/G] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 Silent,Silent,Silent,Silent rs980249 9 106888517 [T/C] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 Silent,Silent,Silent,Silent rs6479217 9 106888978 [T/C] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 EXON Synonymous_Y836Y,Synonymous_Y836Y,Synonymous_Y836Y,Synonymous_Y836Y rs7872034 9 106896809 [A/G] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 EXON Synonymous_L1074L,Synonymous_L1074L,Synonymous_L1074L,Synonymous_L1074L rs6479222 9 106901039 [A/G] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 Silent,Silent,Silent,Silent rs16923746 9 106901506 [A/G] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 EXON Synonymous_V1168V,Synonymous_V1168V,Synonymous_V1168V,Synonymous_V1168V rs15532 9 106901877 [A/C] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 EXON Silent,Silent,Silent,Silent rs4743688 9 106902334 [T/C] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 EXON Silent,Silent,Silent,Silent rs16923750 9 106902388 [T/C] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 EXON Silent,Silent,Silent,Silent rs16923751 9 106902622 [A/G] NM_001042551,NM_001265602,NM_006444,NM_001042550 SMC2,SMC2,SMC2,SMC2 EXON Silent,Silent,Silent,Silent rs6479223 9 106921023 [T/C] rs10991137 9 106925008 [T/C] rs12351427 9 106926807 [A/C] rs12351429 9 106935585 [T/C] rs966390 9 106944031 [A/G] rs1507506 9 106956123 [A/G] rs1122879 9 106961811 [A/C] rs10991172 9 106976151 [T/C] rs1507515 9 106989653 [A/G] rs10124553 9 106993898 [A/G] rs2122582 9 107009131 [T/C] rs10120365 9 107013530 [A/G] rs4743702 9 107013881 [T/C] rs7034022 9 107021689 [T/G] rs1450679 9 107026812 [T/C] rs1597513 9 107028394 [T/C] rs1450675 9 107029309 [T/C] rs10991205 9 107038190 [T/C] NR_135141 LOC105376194 Silent rs4743703 9 107041827 [T/C] NR_135141 LOC105376194 Silent rs1507511 9 107045058 [T/G] NR_135141 LOC105376194 Silent rs1395832 9 107047590 [T/C] NR_135141 LOC105376194 Silent rs1354892 9 107050093 [T/C] rs7034055 9 107051846 [T/C] rs10521067 9 107054520 [A/G] rs3012359 9 107055840 [T/C] rs2991282 9 107056086 [A/G] rs867977 9 107056847 [T/C] rs884258 9 107057177 [T/C] rs10820631 9 107063817 [A/G] rs7847263 9 107073849 [T/G] rs7867773 9 107075223 [A/C] rs4743707 9 107076147 [A/G] rs13299767 9 107083282 [A/G] rs13291235 9 107084182 [T/C] rs1688666 9 107097929 [T/C] rs7857557 9 107100866 [T/C] rs6479233 9 107100917 [T/C] rs12238305 9 107101626 [T/C] rs10991225 9 107104909 [T/C] rs10991227 9 107108324 [T/C] rs2933323 9 107113739 [T/C] rs16923933 9 107121314 [T/C] rs3012352 9 107125805 [T/C] rs3000671 9 107128724 [A/C] rs3012353 9 107129400 [T/C] rs7048700 9 107130684 [T/C] rs7029615 9 107138679 [T/C] rs6479234 9 107154109 [A/G] rs1565603 9 107154562 [A/G] rs1565604 9 107154760 [A/G] rs10991262 9 107180109 [A/G] rs9299380 9 107199088 [T/G] rs902788 9 107227109 [T/C] rs1388752 9 107227614 [T/C] rs698459 9 107234158 [T/G] rs10820643 9 107242297 [T/C] rs10820644 9 107245354 [A/G] rs1916678 9 107246760 [A/G] rs10820650 9 107257406 [T/C] rs7849956 9 107259865 [A/G] rs2417531 9 107263182 [A/G] rs1464674 9 107265452 [T/G] rs10820661 9 107265989 [T/C] rs1403812 9 107266844 [A/G] NM_001004485 OR13F1 EXON Missense_M101V rs1403811 9 107266943 [A/G] NM_001004485 OR13F1 EXON Missense_V134I rs7030820 9 107267304 [T/C] NM_001004485 OR13F1 EXON Missense_T254M rs7025484 9 107273553 [A/G] rs2900371 9 107279558 [A/G] rs7869860 9 107280314 [A/C] rs6479245 9 107281379 [T/C] rs10761033 9 107292001 [T/C] rs1523668 9 107293126 [A/G] rs1523667 9 107293318 [T/C] rs12349993 9 107293507 [A/G] rs7872276 9 107293713 [T/G] rs12003257 9 107294021 [A/G] rs10761034 9 107294722 [T/G] rs6479247 9 107297337 [A/C] rs6479250 9 107300612 [T/G] rs10991297 9 107304806 [A/G] rs10465155 9 107311368 [A/G] rs6479251 9 107312272 [A/G] rs4742914 9 107312475 [A/G] rs10991298 9 107313406 [A/G] rs13287980 9 107324200 [A/G] rs13289787 9 107324247 [A/G] rs1403822 9 107327794 [T/C] rs7026705 9 107331504 [A/C] NM_001004483 OR13C8 EXON Missense_A19D rs10125033 9 107341255 [T/C] rs10820670 9 107341778 [A/C] rs2222490 9 107347173 [A/G] rs6479252 9 107348744 [A/G] rs10761048 9 107349640 [A/G] rs1851725 9 107360826 [A/G] NM_001004482 OR13C5 EXON Missense_M290T rs1523678 9 107360851 [T/C] NM_001004482 OR13C5 EXON Missense_I282V rs1851724 9 107360922 [A/G] NM_001004482 OR13C5 EXON Missense_M258T rs10115731 9 107370498 [A/C] rs1464670 9 107373929 [A/C] rs1523697 9 107375659 [A/C] rs1425570 9 107382410 [A/G] rs929963 9 107390277 [A/G] rs10739902 9 107401344 [A/G] rs2049347 9 107415828 [T/C] rs7872725 9 107419241 [T/C] rs6479273 9 107421824 [T/G] rs13298262 9 107422668 [A/G] rs10820704 9 107424198 [A/G] rs10820705 9 107429678 [A/G] rs7848078 9 107430373 [A/G] rs7043099 9 107436408 [T/C] rs7025373 9 107439675 [A/G] rs1582708 9 107440880 [T/C] rs10991353 9 107450409 [A/C] rs28661924 9 107455576 [A/G] rs1364946 9 107457759 [T/C] rs10761074 9 107463151 [T/C] rs10761076 9 107475166 [A/C] rs1425567 9 107476188 [T/G] rs10820714 9 107477485 [A/G] rs7027419 9 107485577 [T/C] rs1541738 9 107496150 [T/C] rs4743756 9 107505000 [T/C] rs7034016 9 107505262 [A/G] rs10761081 9 107506029 [T/C] rs10739905 9 107506122 [T/C] rs1331926 9 107506490 [T/C] rs10820720 9 107509404 [A/C] rs2417563 9 107509671 [A/G] rs2417564 9 107512888 [A/C] NM_015469,NM_001329570 NIPSNAP3A,NIPSNAP3A Silent,Silent rs4742921 9 107516115 [T/C] NM_015469,NM_001329570 NIPSNAP3A,NIPSNAP3A Silent,Silent rs10761082 9 107516169 [T/C] NM_015469,NM_001329570 NIPSNAP3A,NIPSNAP3A Silent,Silent rs12552611 9 107527830 [T/C] NR_130760,NR_130759,NM_018376 NIPSNAP3B,NIPSNAP3B,NIPSNAP3B Silent,Silent,Silent rs2487714 9 107527916 [A/G] NR_130760,NR_130759,NM_018376 NIPSNAP3B,NIPSNAP3B,NIPSNAP3B Silent,Silent,Silent rs10991376 9 107529689 [T/C] NR_130760,NR_130759,NM_018376 NIPSNAP3B,NIPSNAP3B,NIPSNAP3B Silent,Silent,Silent rs2472476 9 107531956 [T/C] NR_130760,NR_130759,NM_018376 NIPSNAP3B,NIPSNAP3B,NIPSNAP3B Silent,Silent,Silent rs2515606 9 107536895 [A/G] NR_130760,NR_130759,NM_018376 NIPSNAP3B,NIPSNAP3B,NIPSNAP3B EXON Silent,Silent,Silent rs2482430 9 107539352 [T/C] NR_130760,NR_130759,NM_018376 NIPSNAP3B,NIPSNAP3B,NIPSNAP3B EXON Silent,Silent,Silent rs2482432 9 107543172 [T/C] rs4149341 9 107544285 [T/C] NM_005502 ABCA1 EXON Silent rs363717 9 107544700 [T/C] NM_005502 ABCA1 EXON Silent rs4149339 9 107545156 [A/G] NM_005502 ABCA1 EXON Silent rs4149338 9 107545903 [A/G] NM_005502 ABCA1 EXON Silent rs2482433 9 107546901 [A/G] NM_005502 ABCA1 Silent rs1331924 9 107547622 [C/G] NM_005502 ABCA1 Silent rs2777797 9 107548375 [A/C] NM_005502 ABCA1 Silent rs2740485 9 107548493 [T/G] NM_005502 ABCA1 Silent rs2066881 9 107548566 [T/C] NM_005502 ABCA1 Silent rs4149337 9 107548818 [A/G] NM_005502 ABCA1 Silent rs4149336 9 107550639 [A/G] NM_005502 ABCA1 Silent rs2297405 9 107551247 [A/C] NM_005502 ABCA1 Silent rs2297406 9 107551538 [T/C] NM_005502 ABCA1 Silent rs4149333 9 107552924 [A/G] NM_005502 ABCA1 Silent rs2020927 9 107553185 [A/G] NM_005502 ABCA1 Silent rs10121901 9 107553524 [A/G] NM_005502 ABCA1 Silent rs2066720 9 107554069 [T/C] NM_005502 ABCA1 Silent rs4149330 9 107554744 [A/G] NM_005502 ABCA1 Silent rs2297408 9 107555306 [A/G] NM_005502 ABCA1 Silent rs4149326 9 107556349 [T/C] NM_005502 ABCA1 Silent rs4149325 9 107558983 [A/C] NM_005502 ABCA1 Silent rs4149323 9 107560291 [A/G] NM_005502 ABCA1 Silent rs2230808 9 107562804 [T/C] NM_005502 ABCA1 EXON Missense_K1587R rs2777800 9 107563269 [T/C] NM_005502 ABCA1 Silent rs2740479 9 107563437 [A/G] NM_005502 ABCA1 Silent rs1997618 9 107564369 [A/G] NM_005502 ABCA1 EXON Missense_I1555T rs1999431 9 107564676 [T/C] NM_005502 ABCA1 Silent rs914546 9 107564839 [T/C] NM_005502 ABCA1 Silent rs1883023 9 107564846 [T/C] NM_005502 ABCA1 Silent rs4149321 9 107564939 [A/G] NM_005502 ABCA1 Silent rs2066716 9 107568705 [T/C] NM_005502 ABCA1 EXON Synonymous_T1427T rs2777802 9 107569337 [T/C] NM_005502 ABCA1 Silent rs2740476 9 107570714 [C/G] NM_005502 ABCA1 Silent rs2777804 9 107571241 [T/C] NM_005502 ABCA1 Silent rs4149320 9 107573498 [A/G] NM_005502 ABCA1 Silent rs4149319 9 107573757 [A/G] NM_005502 ABCA1 Silent rs2297409 9 107576246 [A/G] NM_005502 ABCA1 Silent rs4149318 9 107577845 [A/C] NM_005502 ABCA1 Silent rs4149317 9 107577946 [A/G] NM_005502 ABCA1 Silent rs3780541 9 107578103 [A/C] NM_005502 ABCA1 Silent rs2234885 9 107578401 [T/C] NM_005502 ABCA1 Silent rs3818688 9 107580657 [A/G] NM_005502 ABCA1 Silent rs2020926 9 107580842 [T/C] NM_005502 ABCA1 Silent rs4149316 9 107581307 [T/C] NM_005502 ABCA1 Silent rs2254884 9 107581749 [A/C] NM_005502 ABCA1 Silent rs3780542 9 107582780 [A/G] NM_005502 ABCA1 Silent rs4149315 9 107584309 [T/C] NM_005502 ABCA1 Silent rs4149314 9 107584351 [T/C] NM_005502 ABCA1 Silent rs9282546 9 107584791 [T/C] NM_005502 ABCA1 EXON Synonymous_G938G rs4149313 9 107586753 [T/C] NM_005502 ABCA1 EXON Missense_I883M rs13291863 9 107587325 [A/G] NM_005502 ABCA1 Silent rs2066715 9 107588033 [T/C] NM_005502 ABCA1 EXON Missense_V825I rs3824477 9 107588328 [A/G] NM_005502 ABCA1 Silent rs4149310 9 107589134 [T/A] NM_005502 ABCA1 Silent rs2066718 9 107589255 [T/C] NM_005502 ABCA1 EXON Missense_V771M rs4149309 9 107589580 [T/A] NM_005502 ABCA1 Silent rs4149308 9 107589630 [T/C] NM_005502 ABCA1 Silent rs4149307 9 107589744 [T/C] NM_005502 ABCA1 Silent rs4149306 9 107589815 [T/C] NM_005502 ABCA1 Silent rs7031748 9 107591272 [T/G] NM_005502 ABCA1 EXON Synonymous_I680I rs2066717 9 107591478 [A/G] NM_005502 ABCA1 Silent rs9282539 9 107593983 [A/G] NM_005502 ABCA1 EXON Synonymous_S545S rs2515629 9 107594364 [A/G] NM_005502 ABCA1 Silent rs4149303 9 107594515 [A/G] NM_005502 ABCA1 Silent rs2065412 9 107598740 [T/C] NM_005502 ABCA1 Silent rs2297398 9 107598884 [T/G] NM_005502 ABCA1 Silent rs4131108 9 107599329 [T/G] NM_005502 ABCA1 EXON Missense_M415L rs2297399 9 107599390 [A/G] NM_005502 ABCA1 Silent rs2297400 9 107599481 [T/C] NM_005502 ABCA1 Silent rs2515601 9 107600193 [A/G] NM_005502 ABCA1 Silent rs4149299 9 107600251 [T/C] NM_005502 ABCA1 Silent rs6479282 9 107601512 [T/C] NM_005502 ABCA1 Silent rs2246841 9 107602666 [T/C] NM_005502 ABCA1 EXON Synonymous_G316G rs2274873 9 107602678 [A/G] NM_005502 ABCA1 EXON Synonymous_P312P rs2472385 9 107603278 [T/C] NM_005502 ABCA1 Silent rs4149297 9 107604104 [A/G] NM_005502 ABCA1 Silent rs2472449 9 107604197 [T/G] NM_005502 ABCA1 Silent rs3824479 9 107604394 [T/A] NM_005502 ABCA1 Silent rs2472448 9 107604507 [T/C] NM_005502 ABCA1 Silent rs4149296 9 107606446 [T/C] NM_005502 ABCA1 Silent rs4149295 9 107607061 [A/T] NM_005502 ABCA1 Silent rs4149294 9 107607371 [G/C] NM_005502 ABCA1 Silent rs4149292 9 107609065 [A/G] NM_005502 ABCA1 Silent rs4149290 9 107611827 [T/C] NM_005502 ABCA1 Silent rs4149288 9 107613050 [A/G] NM_005502 ABCA1 Silent rs2487039 9 107617433 [T/C] NM_005502 ABCA1 Silent rs2472384 9 107618681 [T/C] NM_005502 ABCA1 Silent rs2253304 9 107619063 [A/G] NM_005502 ABCA1 Silent rs2253182 9 107620124 [C/G] NM_005502 ABCA1 Silent rs2253175 9 107620299 [T/C] NM_005502 ABCA1 Silent rs2253174 9 107620332 [A/G] NM_005502 ABCA1 Silent rs2253172 9 107620387 [T/C] NM_005502 ABCA1 Silent rs2230806 9 107620867 [T/C] NM_005502 ABCA1 EXON Missense_R219K rs2243313 9 107621140 [A/C] NM_005502 ABCA1 Silent rs2482420 9 107621638 [A/G] NM_005502 ABCA1 Silent rs4149287 9 107621672 [A/G] NM_005502 ABCA1 Silent rs2487058 9 107623626 [T/C] NM_005502 ABCA1 Silent rs2487059 9 107623750 [T/G] NM_005502 ABCA1 Silent rs2230805 9 107624029 [T/C] NM_005502 ABCA1 EXON Synonymous_L158L rs2249891 9 107624242 [A/G] NM_005502 ABCA1 Silent rs4149286 9 107625803 [T/C] NM_005502 ABCA1 Silent rs4149285 9 107625932 [A/G] NM_005502 ABCA1 Silent rs4149284 9 107626108 [A/G] NM_005502 ABCA1 Silent rs4149283 9 107626189 [T/G] NM_005502 ABCA1 Silent rs4149282 9 107626284 [A/G] NM_005502 ABCA1 Silent rs4149281 9 107626389 [T/C] NM_005502 ABCA1 Silent rs4149280 9 107626542 [T/C] NM_005502 ABCA1 Silent rs4149279 9 107627259 [A/G] NM_005502 ABCA1 Silent rs4743764 9 107629104 [T/C] NM_005502 ABCA1 Silent rs4149278 9 107631081 [A/G] NM_005502 ABCA1 Silent rs1929842 9 107633623 [G/C] NM_005502 ABCA1 Silent rs4742927 9 107634640 [A/G] NM_005502 ABCA1 Silent rs2000069 9 107635869 [T/C] NM_005502 ABCA1 Silent rs4149275 9 107638507 [A/G] NM_005502 ABCA1 Silent rs4149274 9 107639414 [A/G] NM_005502 ABCA1 Silent rs1999429 9 107640786 [T/G] NM_005502 ABCA1 Silent rs4149273 9 107642211 [T/C] NM_005502 ABCA1 Silent rs4149272 9 107642287 [T/C] NM_005502 ABCA1 Silent rs4149271 9 107644287 [A/G] NM_005502 ABCA1 Silent rs3858075 9 107644830 [T/C] NM_005502 ABCA1 Silent rs2275542 9 107645080 [T/C] NM_005502 ABCA1 Silent rs3904998 9 107646260 [T/C] NM_005502 ABCA1 Silent rs11789603 9 107647019 [T/C] NM_005502 ABCA1 Silent rs4149269 9 107647121 [A/G] NM_005502 ABCA1 Silent rs4149268 9 107647220 [T/C] NM_005502 ABCA1 Silent rs3890182 9 107647655 [A/G] NM_005502 ABCA1 Silent rs3847300 9 107648430 [A/G] NM_005502 ABCA1 Silent rs3847303 9 107648652 [T/C] NM_005502 ABCA1 Silent rs10115928 9 107650843 [T/C] NM_005502 ABCA1 Silent rs2275543 9 107651174 [T/C] NM_005502 ABCA1 Silent rs7341705 9 107651348 [T/C] NM_005502 ABCA1 Silent rs4149267 9 107651945 [T/C] NM_005502 ABCA1 Silent rs3824481 9 107652459 [T/C] NM_005502 ABCA1 Silent rs12686004 9 107653426 [A/G] NM_005502 ABCA1 Silent rs3847304 9 107655848 [T/C] NM_005502 ABCA1 Silent rs3905000 9 107657070 [A/G] NM_005502 ABCA1 Silent rs12341993 9 107658910 [A/C] NM_005502 ABCA1 Silent rs2575875 9 107662494 [A/G] NM_005502 ABCA1 Silent rs2791950 9 107662691 [T/C] NM_005502 ABCA1 Silent rs2777788 9 107662701 [A/G] NM_005502 ABCA1 Silent rs4149266 9 107662705 [A/G] NM_005502 ABCA1 Silent rs2777792 9 107663094 [T/C] NM_005502 ABCA1 Silent rs1883025 9 107664301 [T/C] NM_005502 ABCA1 Silent rs2777793 9 107665511 [T/C] NM_005502 ABCA1 Silent rs2575876 9 107665739 [A/G] NM_005502 ABCA1 Silent rs2482424 9 107665751 [T/C] NM_005502 ABCA1 Silent rs2740486 9 107666513 [T/G] NM_005502 ABCA1 Silent rs2575878 9 107667079 [T/C] NM_005502 ABCA1 Silent rs3905001 9 107668064 [G/C] NM_005502 ABCA1 Silent rs2575879 9 107668825 [C/G] NM_005502 ABCA1 Silent rs13284054 9 107669073 [T/C] NM_005502 ABCA1 Silent rs4100654 9 107669241 [T/C] NM_005502 ABCA1 Silent rs10820743 9 107671659 [T/C] NM_005502 ABCA1 Silent rs2777795 9 107672365 [A/G] NM_005502 ABCA1 Silent rs4149265 9 107672498 [A/G] NM_005502 ABCA1 Silent rs12237054 9 107676940 [A/G] NM_005502 ABCA1 Silent rs4149264 9 107677211 [G/C] NM_005502 ABCA1 Silent rs4149263 9 107677289 [A/G] NM_005502 ABCA1 Silent rs4149261 9 107678278 [T/C] NM_005502 ABCA1 Silent rs2515618 9 107678797 [T/C] NM_005502 ABCA1 Silent rs10991408 9 107678916 [T/C] NM_005502 ABCA1 Silent rs13291117 9 107679425 [T/G] NM_005502 ABCA1 Silent rs12336969 9 107679500 [A/C] NM_005502 ABCA1 Silent rs2437811 9 107680458 [T/C] NM_005502 ABCA1 Silent rs10512337 9 107680730 [A/G] NM_005502 ABCA1 Silent rs2515617 9 107680915 [A/G] NM_005502 ABCA1 Silent rs2515616 9 107681995 [A/G] NM_005502 ABCA1 Silent rs7861459 9 107682012 [T/G] NM_005502 ABCA1 Silent rs2791952 9 107682517 [T/C] NM_005502 ABCA1 Silent rs2472508 9 107684253 [A/G] NM_005502 ABCA1 Silent rs10991411 9 107684276 [T/C] NM_005502 ABCA1 Silent rs2487049 9 107684286 [A/G] NM_005502 ABCA1 Silent rs10991415 9 107686354 [A/G] NM_005502 ABCA1 Silent rs2487052 9 107686405 [T/C] NM_005502 ABCA1 Silent rs2437817 9 107690057 [A/C] NM_005502 ABCA1 Silent rs1800977 9 107690450 [A/G] NM_005502 ABCA1 EXON Silent rs2740483 9 107690535 [G/C] rs2422493 9 107690995 [A/G] rs2043664 9 107694245 [A/G] rs2472495 9 107695396 [A/G] rs12553329 9 107698322 [A/G] rs3887137 9 107698612 [T/C] rs2437819 9 107699196 [T/G] rs7848232 9 107701183 [A/G] rs2487031 9 107704228 [A/G] rs2164560 9 107707353 [T/C] rs2472459 9 107710562 [T/C] rs12350492 9 107715566 [T/C] rs2472519 9 107715878 [A/G] rs2472516 9 107716396 [A/G] rs1561166 9 107720025 [T/C] rs4397467 9 107722578 [A/G] rs2009462 9 107724076 [A/G] rs10991432 9 107726070 [A/G] rs9919066 9 107726821 [T/C] rs12380341 9 107731568 [T/C] rs7023634 9 107731789 [A/G] rs4556142 9 107734714 [A/G] rs10991437 9 107735920 [A/C] rs1808789 9 107736034 [T/G] rs715119 9 107737393 [T/C] rs12379205 9 107739312 [T/C] rs10761089 9 107740191 [A/G] rs10991440 9 107743081 [A/G] rs4743784 9 107744661 [A/G] rs12342875 9 107744958 [T/C] rs2016226 9 107749399 [T/C] rs10991446 9 107751571 [T/C] rs7019610 9 107751593 [A/G] rs4743785 9 107754330 [T/C] rs10820754 9 107760227 [T/G] rs6479289 9 107767036 [A/G] rs13283838 9 107770227 [A/C] rs12000585 9 107770256 [A/G] rs12340129 9 107778690 [A/G] rs2417598 9 107782100 [T/C] rs4551427 9 107782109 [T/C] rs1827324 9 107784172 [A/G] rs10991473 9 107786886 [A/G] rs328875 9 107786913 [T/C] rs12336401 9 107786985 [A/G] rs328876 9 107787214 [T/C] rs328879 9 107789252 [A/G] rs328880 9 107790065 [T/C] rs498275 9 107791702 [A/G] rs12346607 9 107792622 [T/C] rs7865004 9 107793314 [A/G] rs443757 9 107793365 [T/C] rs7865251 9 107793488 [A/G] rs375920 9 107795869 [A/G] rs419490 9 107796548 [T/G] rs7850052 9 107797889 [A/G] rs328881 9 107799042 [T/C] rs4743792 9 107799223 [T/C] rs7023868 9 107802222 [T/C] rs7043894 9 107804674 [A/C] rs448085 9 107809019 [T/G] rs387394 9 107809131 [A/G] rs435986 9 107809777 [T/G] rs10820767 9 107810223 [T/G] rs446303 9 107810644 [A/G] rs1809921 9 107814671 [A/G] rs2417603 9 107814816 [A/G] rs1532677 9 107816813 [T/G] rs10991509 9 107819715 [A/G] rs10991510 9 107819733 [A/G] rs1501460 9 107821021 [T/C] rs28497830 9 107826038 [T/G] rs2937372 9 107826647 [A/C] rs882992 9 107827911 [A/G] rs11999215 9 107830552 [A/G] rs10991516 9 107833459 [A/G] rs3132117 9 107833736 [T/C] rs7047382 9 107835785 [A/G] rs3005724 9 107839290 [A/G] rs2937359 9 107839841 [T/C] rs2937352 9 107841964 [T/C] rs3005720 9 107842490 [A/G] rs10820780 9 107851745 [A/G] rs7855885 9 107856028 [T/C] rs1039407 9 107856582 [T/C] rs2173884 9 107857255 [T/C] rs3005716 9 107858481 [T/C] rs989125 9 107860817 [T/C] rs4609251 9 107861083 [A/G] rs7854755 9 107863050 [A/G] rs4742941 9 107866405 [T/G] rs4743805 9 107869834 [A/G] rs3124018 9 107869845 [A/G] rs4743806 9 107870014 [A/C] rs3124016 9 107873231 [A/G] rs10820784 9 107873320 [A/G] rs10991552 9 107877624 [T/C] rs12343892 9 107878643 [A/G] rs7861505 9 107879948 [T/C] rs7858499 9 107881736 [T/C] rs7022410 9 107893381 [A/G] rs7026498 9 107896480 [T/G] rs35211598 9 107910242 [A/G] rs10991561 9 107917632 [T/C] rs7870426 9 107920445 [T/C] rs7856399 9 107921428 [A/C] rs765399 9 107923203 [T/C] rs3005738 9 107929180 [T/G] rs13295440 9 107929206 [T/C] rs12338452 9 107931886 [T/C] rs10991567 9 107934729 [A/G] rs10991580 9 107954622 [T/C] rs12335477 9 107956549 [A/G] rs327971 9 107958534 [A/C] rs10124147 9 107959548 [A/G] rs12343550 9 107961290 [T/C] rs12350390 9 107961947 [T/C] rs7044574 9 107968330 [T/C] rs390253 9 107969815 [T/C] rs395992 9 107973277 [A/C] rs7854392 9 107974737 [A/G] rs412647 9 107975234 [A/C] rs384924 9 107986092 [T/C] rs446641 9 107988197 [T/C] rs370629 9 107989797 [A/C] rs438299 9 107990126 [A/C] rs366144 9 107990623 [T/C] rs422084 9 107990922 [T/G] rs384947 9 107991283 [T/C] rs7847744 9 107992004 [T/C] rs7044876 9 108005902 [T/G] rs327956 9 108008916 [A/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs6479304 9 108010210 [A/C] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs193008 9 108042806 [T/C] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs193007 9 108043166 [A/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs227887 9 108043636 [A/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs327984 9 108054966 [A/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs376926 9 108058559 [A/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs16924420 9 108061597 [A/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs12378850 9 108063472 [T/C] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs9644967 9 108068176 [A/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs10991618 9 108072519 [A/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs12349416 9 108083485 [A/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs10820798 9 108084792 [A/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs10991622 9 108086247 [T/C] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs4387039 9 108087370 [T/C] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs10991629 9 108094256 [T/C] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs7868841 9 108108081 [T/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs10120853 9 108111284 [A/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs7034136 9 108137135 [A/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs3199966 9 108147763 [T/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 EXON Missense_S644A,Missense_S644A,Missense_S644A rs12344130 9 108150015 [T/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs957903 9 108150827 [A/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 Silent,Silent,Silent rs2771040 9 108152199 [A/G] NM_001330731,NM_080546,NM_001286730 SLC44A1,SLC44A1,SLC44A1 EXON Silent,Silent,Silent rs2812314 9 108166606 [T/G] NM_001330731 SLC44A1 Silent rs12340765 9 108166638 [A/G] NM_001330731 SLC44A1 Silent rs16924584 9 108179115 [T/G] NM_001330731 SLC44A1 Silent rs12348331 9 108191511 [A/G] NM_001330731 SLC44A1 Silent rs2812297 9 108207197 [A/G] rs7037141 9 108209066 [T/C] rs7872832 9 108211179 [A/G] NM_001330739,NM_001287192,NM_001287191,NM_031919,NM_001145313 FSD1L,FSD1L,FSD1L,FSD1L,FSD1L Silent,Silent,Silent,Silent,Silent rs10991660 9 108218852 [A/G] NM_001330739,NM_001287192,NM_001287191,NM_031919,NM_001145313 FSD1L,FSD1L,FSD1L,FSD1L,FSD1L Silent,Silent,Silent,Silent,Silent rs10991661 9 108223786 [A/G] NM_001330739,NM_001287192,NM_001287191,NM_031919,NM_001145313 FSD1L,FSD1L,FSD1L,FSD1L,FSD1L Silent,Silent,Silent,Silent,Silent rs10991662 9 108224424 [T/G] NM_001330739,NM_001287192,NM_001287191,NM_031919,NM_001145313 FSD1L,FSD1L,FSD1L,FSD1L,FSD1L Silent,Silent,Silent,Silent,Silent rs2149593 9 108230012 [T/C] NM_001330739,NM_001287192,NM_001287191,NM_031919,NM_001145313 FSD1L,FSD1L,FSD1L,FSD1L,FSD1L Silent,Silent,Silent,Silent,Silent rs2812310 9 108240797 [A/G] NM_001330739,NM_001287192,NM_001287191,NM_001145313 FSD1L,FSD1L,FSD1L,FSD1L Silent,Silent,Silent,Silent rs2771045 9 108243493 [T/C] NM_001330739,NM_001287192,NM_001287191,NM_001145313 FSD1L,FSD1L,FSD1L,FSD1L Silent,Silent,Silent,Silent rs16924672 9 108244576 [A/G] NM_001330739,NM_001287192,NM_001287191,NM_001145313 FSD1L,FSD1L,FSD1L,FSD1L Silent,Silent,Silent,Silent rs2812312 9 108251400 [A/C] NM_001330739,NM_001287192,NM_001287191,NM_001145313 FSD1L,FSD1L,FSD1L,FSD1L Silent,Silent,Silent,Silent rs10820813 9 108276704 [T/C] NM_001330739,NM_001287192,NM_001287191,NM_001145313 FSD1L,FSD1L,FSD1L,FSD1L Silent,Silent,Silent,Silent rs1327351 9 108298183 [A/G] NM_001330739,NM_001287192,NM_001287191,NM_001145313 FSD1L,FSD1L,FSD1L,FSD1L Silent,Silent,Silent,Silent rs16924704 9 108300186 [A/G] NM_001330739,NM_001287192,NM_001287191,NM_001145313 FSD1L,FSD1L,FSD1L,FSD1L Silent,Silent,Silent,Silent rs1327353 9 108348889 [T/C] NM_001351500,NM_001351497,NR_147213,NM_001351501,NM_001198963,NM_001351499,NM_001351496,NR_147214,NM_001351498,NM_001079802,NM_001351502,NM_006731 FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2768291 9 108350181 [A/G] NM_001351500,NM_001351497,NR_147213,NM_001351501,NM_001198963,NM_001351499,NM_001351496,NR_147214,NM_001351498,NM_001079802,NM_001351502,NM_006731 FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2518129 9 108371337 [A/G] NM_001351500,NM_001351497,NR_147213,NM_001351501,NM_001198963,NM_001351499,NM_001351496,NR_147214,NM_001351498,NM_001079802,NM_001351502,NM_006731 FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2518130 9 108373054 [A/G] NM_001351500,NM_001351497,NR_147213,NM_001351501,NM_001198963,NM_001351499,NM_001351496,NR_147214,NM_001351498,NM_001079802,NM_001351502,NM_006731 FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2417625 9 108373184 [A/C] NM_001351500,NM_001351497,NR_147213,NM_001351501,NM_001198963,NM_001351499,NM_001351496,NR_147214,NM_001351498,NM_001079802,NM_001351502,NM_006731 FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4742955 9 108377097 [A/G] NM_001351500,NM_001351497,NR_147213,NM_001351501,NM_001198963,NM_001351499,NM_001351496,NR_147214,NM_001351498,NM_001079802,NM_001351502,NM_006731 FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10816284 9 108380004 [A/G] NM_001351500,NM_001351497,NR_147213,NM_001351501,NM_001198963,NM_001351499,NM_001351496,NR_147214,NM_001351498,NM_001079802,NM_001351502,NM_006731 FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17309806 9 108380355 [A/C] NM_001351500,NM_001351497,NR_147213,NM_001351501,NM_001198963,NM_001351499,NM_001351496,NR_147214,NM_001351498,NM_001079802,NM_001351502,NM_006731 FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN EXON Synonymous_L210L,Synonymous_L319L,Silent,Synonymous_L210L,Synonymous_L342L,Synonymous_L210L,Synonymous_L342L,Silent,Synonymous_L342L,Synonymous_L342L,Synonymous_L210L,Synonymous_L342L rs2768282 9 108398678 [A/G] NM_001351500,NM_001351497,NR_147213,NM_001351501,NM_001198963,NM_001351499,NM_001351496,NR_147214,NM_001351498,NM_001079802,NM_001351502,NM_006731 FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1024366 9 108399825 [T/C] NM_001351500,NM_001351497,NR_147213,NM_001351501,NM_001198963,NM_001351499,NM_001351496,NR_147214,NM_001351498,NM_001079802,NM_001351502,NM_006731 FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN,FKTN EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10978179 9 108404763 [A/G] rs1858743 9 108405344 [T/C] rs885954 9 108409400 [A/C] rs17251166 9 108409614 [T/C] rs605419 9 108413323 [A/C] rs635712 9 108415556 [T/C] rs567831 9 108417743 [A/G] rs583973 9 108418212 [A/C] rs10816292 9 108423366 [T/G] rs1463983 9 108426784 [T/C] rs1463984 9 108427062 [T/C] rs1409922 9 108428303 [A/C] rs12346758 9 108431740 [T/C] rs16924823 9 108431783 [T/C] rs9299108 9 108434007 [A/G] rs7047678 9 108442205 [A/G] rs1567368 9 108443332 [A/G] rs10816295 9 108449986 [A/C] rs7039618 9 108457806 [A/G] NM_018112 TMEM38B Silent rs3817141 9 108468129 [T/C] NM_018112 TMEM38B Silent rs10733555 9 108471563 [T/C] NM_018112 TMEM38B Silent rs10978213 9 108471885 [A/G] NM_018112 TMEM38B Silent rs10739211 9 108474679 [A/C] NM_018112 TMEM38B Silent rs9408800 9 108479126 [A/G] NM_018112 TMEM38B Silent rs10978230 9 108504621 [T/C] NM_018112 TMEM38B Silent rs12348005 9 108506720 [T/C] NM_018112 TMEM38B Silent rs10759135 9 108521693 [A/G] NM_018112 TMEM38B Silent rs10465120 9 108523710 [T/G] NM_018112 TMEM38B Silent rs1979993 9 108534505 [T/C] NM_018112 TMEM38B Silent rs10978240 9 108535272 [A/G] NM_018112 TMEM38B Silent rs3010417 9 108568402 [A/G] rs10978293 9 108583206 [T/C] rs872246 9 108592589 [A/G] rs10512341 9 108595364 [T/C] rs7872125 9 108596042 [T/C] rs17282567 9 108597465 [T/G] rs6477473 9 108603039 [A/C] rs12346407 9 108605956 [T/C] rs3105991 9 108608674 [T/C] rs1806664 9 108626502 [T/C] rs2997726 9 108626919 [A/G] rs6477476 9 108629422 [A/C] rs7872318 9 108633515 [T/C] rs3010959 9 108641808 [T/C] rs6477479 9 108642694 [A/G] rs6477480 9 108642738 [A/G] rs2417654 9 108643176 [T/G] rs13440292 9 108648392 [T/C] rs4742971 9 108655096 [T/G] rs4598317 9 108656238 [A/C] rs10115085 9 108663489 [T/C] rs7030289 9 108672309 [T/C] rs2417658 9 108674392 [T/C] rs4742974 9 108678284 [T/G] rs10124983 9 108678497 [A/C] rs2417660 9 108680292 [T/C] rs2417661 9 108681246 [A/G] rs2417662 9 108681706 [A/G] rs1987249 9 108683134 [A/C] rs1987248 9 108683365 [T/C] rs10759153 9 108684675 [A/G] rs10816354 9 108688554 [A/G] rs10978345 9 108689648 [A/G] rs4742659 9 108694397 [A/G] rs7044893 9 108700188 [A/G] rs13293907 9 108702986 [T/C] rs10816356 9 108717969 [T/G] rs10816357 9 108722123 [A/G] rs7866652 9 108732469 [T/C] rs10978362 9 108733453 [A/G] rs16925085 9 108739271 [A/G] rs17285571 9 108740616 [T/C] rs4336667 9 108740661 [A/G] rs10978363 9 108742160 [T/C] rs7870421 9 108742371 [A/G] rs12006289 9 108749726 [A/C] rs7867860 9 108759480 [T/C] rs10759158 9 108761012 [T/C] rs2417682 9 108779678 [A/G] rs9886710 9 108785618 [T/G] rs10816368 9 108791327 [T/G] rs4255200 9 108793429 [A/G] rs7468493 9 108798258 [A/G] rs4742661 9 108807861 [T/C] rs7852935 9 108808480 [T/C] rs10816370 9 108814037 [A/G] rs4418395 9 108817987 [T/C] rs10116405 9 108822093 [T/C] rs4128998 9 108823761 [A/G] rs4587393 9 108827402 [A/G] rs10978399 9 108830272 [A/G] rs13299446 9 108838212 [T/C] rs10512343 9 108839164 [A/G] rs971416 9 108846468 [A/G] rs10978413 9 108854018 [T/C] rs10978416 9 108857533 [T/G] rs9409077 9 108862046 [T/C] rs885578 9 108866460 [A/C] rs925837 9 108868577 [T/C] rs10978421 9 108869252 [T/C] rs1850356 9 108871088 [A/G] rs12349986 9 108875720 [T/C] rs1516893 9 108877645 [A/C] rs9299118 9 108878030 [A/G] rs12236453 9 108878507 [T/C] rs4742987 9 108882218 [A/G] rs1120147 9 108893840 [A/G] rs1120146 9 108893850 [T/C] rs4742988 9 108895689 [A/G] rs1400438 9 108898935 [T/C] rs9409083 9 108901466 [A/G] rs1516885 9 108902045 [T/C] rs1516882 9 108912911 [A/G] rs7038938 9 108916895 [A/G] rs12004214 9 108918909 [T/G] rs12353538 9 108923289 [T/C] rs2417687 9 108923457 [A/G] rs13300395 9 108926464 [A/G] rs7028916 9 108927068 [A/C] rs7864765 9 108949905 [T/G] rs7019548 9 108954738 [A/C] rs1114461 9 108957715 [T/G] rs2900408 9 108958893 [A/G] rs7862517 9 108981298 [A/G] rs1516888 9 108983165 [A/G] rs7030412 9 109000891 [T/C] rs12005566 9 109004064 [A/G] rs12001760 9 109004346 [A/G] rs16925314 9 109010135 [T/G] rs1484372 9 109010799 [T/G] rs2627741 9 109014185 [A/G] rs2417688 9 109018525 [T/C] rs10759172 9 109031079 [T/C] rs16936272 9 109043885 [A/G] rs12344579 9 109046007 [A/G] rs16925340 9 109047913 [T/C] rs7043293 9 109065718 [A/G] rs1484375 9 109067561 [A/G] rs12683342 9 109088848 [A/G] rs10116613 9 109089589 [A/G] rs1876376 9 109094026 [T/C] rs12686474 9 109104850 [A/G] rs6477505 9 109118797 [A/C] rs10978470 9 109136192 [T/C] rs13293802 9 109138185 [A/G] rs12001203 9 109140030 [T/C] rs955062 9 109147362 [T/C] rs10759178 9 109149614 [T/G] rs7846958 9 109150272 [A/G] rs10759179 9 109153027 [T/C] rs10816387 9 109154423 [A/G] rs7857609 9 109154569 [T/G] rs6477511 9 109155467 [A/G] rs12352728 9 109158155 [T/C] rs7866564 9 109160164 [T/G] rs10759180 9 109162816 [A/G] rs10739222 9 109164956 [T/G] rs10759181 9 109166421 [T/C] rs17218614 9 109177377 [A/G] rs4434671 9 109178575 [A/G] rs13293858 9 109179510 [T/C] rs11794472 9 109179823 [A/G] rs17291025 9 109181134 [T/G] rs902143 9 109181911 [T/C] rs7866482 9 109182762 [T/C] rs7041138 9 109184595 [T/C] rs10113989 9 109185446 [T/C] rs10114641 9 109185593 [T/C] rs7042670 9 109189050 [A/G] rs6477516 9 109189121 [A/G] rs10978480 9 109190563 [T/C] rs1352593 9 109193717 [A/G] rs13294274 9 109196180 [A/G] rs7024043 9 109197082 [A/G] rs10978485 9 109197883 [A/G] rs980616 9 109198515 [A/C] rs16925492 9 109201514 [T/C] rs4742996 9 109205296 [A/G] rs2417709 9 109211561 [A/G] rs2417710 9 109211719 [T/C] rs4742669 9 109215469 [A/G] rs12552379 9 109216259 [A/G] rs7855719 9 109218799 [T/C] rs17291806 9 109222859 [A/G] rs989980 9 109230037 [T/C] rs10512345 9 109233625 [T/C] rs13288836 9 109233842 [A/C] rs16925511 9 109240561 [A/C] rs12343588 9 109245779 [T/C] rs1387595 9 109252423 [A/G] rs12338993 9 109260333 [A/G] rs6477523 9 109265076 [T/G] rs1472029 9 109270732 [A/G] rs10978504 9 109273253 [T/C] rs9696881 9 109274146 [A/G] rs7873699 9 109274388 [T/C] rs6477524 9 109275588 [T/C] rs1602111 9 109277184 [A/C] rs7847257 9 109290849 [T/C] rs16925535 9 109291197 [T/C] rs1532115 9 109291610 [T/C] rs931425 9 109292568 [A/G] rs7018699 9 109296536 [A/C] rs7042522 9 109297588 [T/C] rs10978516 9 109298040 [T/C] rs10978518 9 109299254 [T/C] rs10978525 9 109308266 [T/G] rs7865489 9 109312922 [T/G] rs10978534 9 109317378 [T/G] rs10978535 9 109319711 [T/C] rs10759187 9 109321284 [T/C] rs962395 9 109323247 [T/G] rs6477527 9 109323457 [A/G] rs10115173 9 109325757 [A/C] rs4743005 9 109327591 [A/G] rs7024815 9 109339950 [T/C] rs1489667 9 109344847 [A/G] rs10978550 9 109345993 [T/C] rs1907438 9 109348980 [A/G] rs10759188 9 109350497 [A/G] rs7871327 9 109362226 [A/G] rs16925649 9 109363730 [A/G] rs10816399 9 109364146 [T/G] rs10816400 9 109365223 [A/G] rs12379601 9 109373732 [T/C] rs10978560 9 109379687 [A/G] NR_104145 LINC01505 Silent rs12350093 9 109386686 [A/G] NR_104145 LINC01505 Silent rs11792106 9 109389147 [A/G] NR_104145 LINC01505 Silent rs984551 9 109390820 [T/C] NR_104145 LINC01505 Silent rs2220623 9 109391774 [A/G] NR_104145 LINC01505 Silent rs7854430 9 109393045 [A/G] NR_104145 LINC01505 Silent rs7865945 9 109393881 [A/G] NR_104145 LINC01505 Silent rs12002108 9 109393957 [T/C] NR_104145 LINC01505 Silent rs1491113 9 109394613 [A/G] NR_104145 LINC01505 Silent rs7874140 9 109403237 [A/G] NR_104145 LINC01505 Silent rs7044278 9 109403758 [T/C] NR_104145 LINC01505 Silent rs12349610 9 109404422 [A/G] NR_104145 LINC01505 Silent rs2417753 9 109405667 [A/G] NR_104145 LINC01505 Silent rs7855642 9 109410667 [A/G] NR_104145 LINC01505 Silent rs2417713 9 109417359 [A/G] NR_104145 LINC01505 Silent rs10118378 9 109423202 [A/G] NR_104145 LINC01505 Silent rs10978589 9 109426449 [A/G] NR_104145 LINC01505 Silent rs7864733 9 109427261 [T/G] NR_104145 LINC01505 Silent rs12377606 9 109446277 [A/G] rs12346852 9 109458089 [T/C] rs10816421 9 109459475 [T/C] rs10759193 9 109459699 [A/G] rs12340308 9 109461883 [T/C] rs16925749 9 109465397 [T/C] rs1491103 9 109468107 [A/G] rs16925750 9 109469564 [A/G] rs2417751 9 109469833 [T/C] rs10978602 9 109470258 [A/G] rs10816422 9 109470527 [A/G] rs1491101 9 109473227 [A/G] rs10122952 9 109473787 [T/C] rs1388235 9 109475636 [A/C] rs12002898 9 109478331 [A/G] rs13291742 9 109480510 [A/G] rs3936578 9 109482027 [A/C] rs10978610 9 109485116 [T/C] rs2498861 9 109492294 [A/C] rs7041150 9 109494624 [A/C] rs7863929 9 109497528 [T/C] rs10122119 9 109503011 [T/C] rs7036275 9 109506245 [T/G] rs10978620 9 109507545 [T/C] rs1491099 9 109508320 [A/C] rs2172111 9 109513291 [T/G] rs16925815 9 109517535 [A/G] rs2451948 9 109518208 [A/G] rs725773 9 109519849 [T/C] rs716875 9 109520131 [A/G] rs2493636 9 109520821 [A/G] rs2493637 9 109521257 [T/C] rs17194561 9 109522849 [A/G] rs10978628 9 109529338 [A/G] rs7022991 9 109531515 [T/C] rs10978631 9 109531966 [T/C] rs7873059 9 109533269 [A/G] rs7858184 9 109538577 [T/G] rs7048770 9 109538962 [T/G] rs4237185 9 109542204 [T/C] rs10978639 9 109548485 [A/G] rs4128264 9 109557941 [A/G] rs10978647 9 109566506 [A/G] rs10978651 9 109579213 [T/C] rs4742675 9 109581132 [A/C] rs4625093 9 109592778 [A/G] rs9792598 9 109598171 [T/C] rs10283476 9 109614849 [T/C] rs10978661 9 109618474 [T/C] rs7850188 9 109618643 [T/C] rs7863663 9 109624255 [T/G] rs4743034 9 109632353 [A/G] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs9299129 9 109638167 [A/G] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs10978664 9 109640836 [A/G] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs6477547 9 109644865 [T/C] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs3814542 9 109653221 [T/C] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs907064 9 109658333 [T/G] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs7020870 9 109661016 [T/G] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs16925920 9 109673244 [A/G] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs1567451 9 109675354 [A/G] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs10816453 9 109676250 [A/G] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs1858231 9 109676893 [A/G] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs11789013 9 109677417 [T/C] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs10816455 9 109679767 [A/G] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs10978672 9 109682501 [A/G] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs1000152 9 109687288 [T/C] NM_001347997,NM_021224 ZNF462,ZNF462 EXON Synonymous_Y365Y,Synonymous_Y365Y rs17723637 9 109687403 [A/G] NM_001347997,NM_021224 ZNF462,ZNF462 EXON Missense_M404V,Missense_M404V rs3814540 9 109689859 [T/C] NM_001347997,NM_021224 ZNF462,ZNF462 EXON Silent,Synonymous_N1222N rs7020769 9 109697822 [A/G] NM_001347997,NM_021224 ZNF462,ZNF462 EXON Missense_K1187R,Missense_K2052R rs4743039 9 109699547 [T/C] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs7868949 9 109708207 [T/C] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs10978683 9 109715419 [T/C] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs6477551 9 109728072 [A/G] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs1510285 9 109733743 [A/G] NM_001347997,NM_021224 ZNF462,ZNF462 Silent,Silent rs10978689 9 109740520 [T/C] NM_001347997,NM_021224,NR_126029 ZNF462,ZNF462,LOC340512 Silent,Silent,Silent rs10978691 9 109741309 [A/C] NM_001347997,NM_021224,NR_126029 ZNF462,ZNF462,LOC340512 Silent,Silent,Silent rs16926038 9 109748164 [T/C] NM_001347997,NM_021224,NR_126029 ZNF462,ZNF462,LOC340512 Silent,Silent,Silent rs10978695 9 109757432 [T/G] NM_001347997,NM_021224,NR_126029 ZNF462,ZNF462,LOC340512 Silent,Silent,Silent rs1876985 9 109762044 [A/C] NM_001347997,NM_021224,NR_126029 ZNF462,ZNF462,LOC340512 Silent,Silent,Silent rs10978698 9 109764204 [T/C] NM_001347997,NM_021224,NR_126029 ZNF462,ZNF462,LOC340512 Silent,Silent,Silent rs12343909 9 109770755 [A/G] NM_001347997,NM_021224,NR_126029 ZNF462,ZNF462,LOC340512 Silent,Silent,Silent rs7853813 9 109787178 [T/C] NR_126029 LOC340512 Silent rs10816461 9 109793425 [A/G] NR_126029 LOC340512 Silent rs7390631 9 109796197 [T/G] NR_126029 LOC340512 Silent rs10759208 9 109806199 [T/C] NR_126029 LOC340512 Silent rs6477555 9 109809259 [A/G] NR_126029 LOC340512 Silent rs696562 9 109809366 [T/C] NR_126029 LOC340512 Silent rs784790 9 109812226 [A/G] NR_126029 LOC340512 Silent rs10739230 9 109813447 [T/C] NR_126029 LOC340512 Silent rs7874831 9 109815352 [A/G] NR_126029 LOC340512 Silent rs13440459 9 109819106 [T/C] NR_126029 LOC340512 Silent rs4492441 9 109819184 [T/C] NR_126029 LOC340512 Silent rs12345400 9 109819621 [A/G] NR_126029 LOC340512 Silent rs784649 9 109827660 [T/G] NR_126029 LOC340512 Silent rs1519040 9 109838977 [T/C] NR_126029 LOC340512 Silent rs10978713 9 109839490 [A/G] NR_126029 LOC340512 Silent rs4443716 9 109843602 [A/G] NR_126029 LOC340512 Silent rs7861530 9 109848914 [T/C] NR_126029 LOC340512 Silent rs1714460 9 109857771 [T/C] NR_126029 LOC340512 Silent rs16912206 9 109862984 [T/C] NR_126029 LOC340512 Silent rs784661 9 109863693 [A/G] NR_126029 LOC340512 Silent rs7029669 9 109868858 [T/C] rs7044846 9 109869532 [A/G] rs784664 9 109872374 [A/G] rs1878735 9 109873993 [A/C] rs784660 9 109880985 [T/C] rs939094 9 109881346 [T/C] rs1007061 9 109882332 [A/G] rs7848294 9 109885897 [A/G] rs12002945 9 109890250 [A/G] rs10759209 9 109890759 [A/G] rs7031681 9 109892061 [T/C] rs1105848 9 109892770 [T/C] rs10978723 9 109894432 [A/G] rs7864018 9 109895391 [T/C] rs7858186 9 109897161 [T/C] rs784683 9 109898877 [A/G] rs7026685 9 109899802 [A/G] rs9696036 9 109900756 [T/C] rs12351052 9 109903423 [T/C] rs10122653 9 109904573 [A/G] rs956578 9 109905613 [T/C] rs1714474 9 109907509 [A/G] rs1714473 9 109910721 [A/G] rs7849325 9 109911084 [A/G] rs784677 9 109912451 [T/C] rs784676 9 109912752 [A/C] rs784670 9 109915716 [T/C] rs908725 9 109916235 [A/G] rs871625 9 109921231 [A/G] rs10978733 9 109923051 [T/G] rs17195683 9 109926563 [A/G] rs10978734 9 109926894 [T/C] rs16912263 9 109928973 [A/G] rs6477562 9 109931412 [A/C] rs4443717 9 109940271 [A/G] rs10978740 9 109942554 [T/G] rs2417773 9 109943165 [T/C] rs11999603 9 109946944 [T/C] rs7032927 9 109949144 [A/G] rs1464250 9 109953472 [T/C] rs12335940 9 109954497 [A/G] rs1519039 9 109954812 [T/C] rs2203829 9 109957950 [T/C] rs12336793 9 109960553 [T/G] rs12336762 9 109960591 [T/C] rs2417775 9 109961354 [A/G] rs2680198 9 109971491 [T/G] rs2680197 9 109972066 [T/G] rs2680195 9 109973450 [A/G] rs2680208 9 109978917 [A/G] rs10978757 9 109981481 [A/G] rs13292544 9 109986449 [A/G] rs10978761 9 109986827 [T/C] rs2808374 9 109987079 [A/G] rs7859324 9 109989135 [A/C] rs1519049 9 109991942 [A/G] rs2680216 9 109995551 [T/C] rs2808363 9 109998563 [A/G] rs17724552 9 110000354 [A/G] rs10978764 9 110001533 [A/G] rs4978764 9 110002647 [A/G] rs12004883 9 110006333 [A/G] rs10978769 9 110008143 [A/G] rs12000093 9 110009895 [A/C] rs7867544 9 110013980 [T/C] rs10816477 9 110022842 [T/C] rs942291 9 110031745 [T/C] rs12345455 9 110032498 [T/G] rs10816481 9 110042484 [T/C] rs7041137 9 110044572 [T/C] rs10739235 9 110047794 [T/C] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs12005522 9 110052660 [T/C] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs10217136 9 110055279 [T/C] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs11573633 9 110055967 [A/G] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs10759222 9 110056739 [A/G] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs11573648 9 110057838 [A/G] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs11573653 9 110058358 [T/C] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs11573662 9 110063197 [T/C] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs7023656 9 110075437 [T/C] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs942292 9 110076032 [T/C] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs7025563 9 110078582 [T/C] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs7868125 9 110079186 [A/G] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs16912372 9 110079453 [A/G] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs2417784 9 110083764 [T/C] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs1805330 9 110084261 [T/C] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs1323809 9 110084832 [T/C] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs11573709 9 110085255 [A/G] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs11573721 9 110086951 [A/G] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B Silent,Silent,Silent rs10868 9 110092856 [T/C] NM_002874,NM_001244724,NM_001244713 RAD23B,RAD23B,RAD23B EXON Silent,Silent,Silent rs10816493 9 110100745 [T/C] rs817844 9 110101440 [T/G] rs817852 9 110106222 [T/C] rs716004 9 110107862 [T/C] rs10816494 9 110112190 [T/C] rs817854 9 110113919 [A/G] rs10978803 9 110114432 [A/G] rs10816499 9 110116369 [T/C] rs7866008 9 110120871 [A/G] rs10759229 9 110127130 [T/C] rs10739243 9 110130919 [T/C] rs1538985 9 110131397 [A/C] rs817861 9 110132198 [A/G] rs12375540 9 110136208 [T/C] rs1746837 9 110141811 [A/G] rs10122670 9 110142277 [T/C] rs11792269 9 110144329 [T/G] rs817870 9 110144688 [T/C] rs1771723 9 110150168 [T/C] rs1622267 9 110150659 [A/G] rs1771717 9 110151512 [A/G] rs7029300 9 110152533 [T/G] rs817829 9 110155358 [A/G] rs817827 9 110156279 [T/C] rs817826 9 110156300 [T/C] rs817824 9 110159566 [T/C] rs12004443 9 110167103 [T/C] rs9299131 9 110167168 [T/C] rs947125 9 110167768 [T/C] rs10978837 9 110168438 [A/C] rs16912495 9 110168617 [T/G] rs7861976 9 110171107 [T/C] rs4978954 9 110183891 [T/C] NR_121581 LINC01509 Silent rs4978955 9 110184048 [A/G] NR_121581 LINC01509 Silent rs1572905 9 110184645 [A/G] NR_121581 LINC01509 Silent rs12336348 9 110185695 [T/C] NR_121581 LINC01509 Silent rs13288073 9 110185887 [T/G] NR_121581 LINC01509 Silent rs10978847 9 110187151 [T/G] NR_121581 LINC01509 Silent rs10739244 9 110188197 [A/G] NR_121581 LINC01509 Silent rs17196438 9 110193442 [T/C] NR_121581 LINC01509 Silent rs10816506 9 110195120 [A/G] NR_121581 LINC01509 Silent rs947126 9 110195358 [A/G] NR_121581 LINC01509 Silent rs12379012 9 110195598 [T/C] NR_121581 LINC01509 Silent rs12342660 9 110196197 [T/C] NR_121581 LINC01509 Silent rs2417791 9 110197029 [T/C] NR_121581 LINC01509 Silent rs10759234 9 110204166 [T/G] NR_121581 LINC01509 Silent rs10978858 9 110205831 [A/G] NR_121581 LINC01509 Silent rs10816508 9 110206622 [T/C] NR_121581 LINC01509 Silent rs10978861 9 110210362 [A/G] NR_121581 LINC01509 Silent rs10759237 9 110214347 [A/G] NR_121581 LINC01509 Silent rs12555837 9 110214615 [T/C] NR_121581 LINC01509 Silent rs947122 9 110217097 [A/G] NR_121581 LINC01509 EXON Silent rs882942 9 110217742 [A/C] NR_121581 LINC01509 Silent rs7035256 9 110226138 [A/G] NR_121581 LINC01509 Silent rs1832881 9 110229609 [T/C] rs10759238 9 110231170 [A/G] rs1819730 9 110231863 [A/G] rs17725250 9 110238361 [A/G] rs1832741 9 110241529 [T/C] rs10816518 9 110243031 [A/C] rs10816519 9 110245984 [T/C] rs4448339 9 110271554 [A/C] rs10816523 9 110274062 [T/C] rs12348272 9 110275986 [T/C] rs4979041 9 110277340 [A/G] rs7041758 9 110280496 [T/C] rs10816526 9 110293247 [T/C] rs10119193 9 110296686 [T/C] rs10978905 9 110297442 [A/G] rs4979065 9 110300994 [A/G] rs2185857 9 110303463 [A/G] rs10122326 9 110311124 [A/G] rs10512383 9 110311539 [A/G] rs2258170 9 110319927 [A/G] rs2258660 9 110326874 [T/C] rs1573048 9 110328726 [A/C] rs7045952 9 110332569 [T/G] rs10978931 9 110346728 [A/G] rs11792587 9 110350727 [A/G] rs1935973 9 110354209 [A/C] rs4979136 9 110360883 [T/C] rs7034018 9 110363564 [T/C] rs7019214 9 110365337 [A/G] rs10816539 9 110369095 [T/C] rs10816540 9 110370455 [A/G] rs7869457 9 110376654 [T/C] rs10978945 9 110377174 [T/C] rs12682930 9 110379567 [T/G] rs2017419 9 110382117 [T/G] rs7022385 9 110383280 [A/G] rs1110403 9 110383583 [A/G] rs10759245 9 110384379 [T/C] rs10978947 9 110386734 [A/G] rs6477586 9 110388405 [A/C] rs10978950 9 110389815 [T/C] rs11794132 9 110396073 [T/C] rs7864185 9 110397107 [A/G] rs12001098 9 110407586 [A/G] rs12337942 9 110410967 [T/C] rs4978532 9 110416006 [A/C] rs7849612 9 110418574 [A/G] rs11790667 9 110419649 [A/G] rs10816543 9 110422723 [A/G] rs10816544 9 110422729 [A/G] rs4979219 9 110424020 [T/C] rs7040614 9 110424575 [T/C] rs12351531 9 110431994 [A/G] rs10978988 9 110432131 [A/G] rs10816550 9 110435868 [A/G] rs940290 9 110436899 [T/G] rs940289 9 110436968 [A/G] rs940288 9 110436996 [A/G] rs10978995 9 110438418 [T/C] rs10978996 9 110438441 [T/C] rs10816552 9 110438476 [T/C] rs4979249 9 110448724 [A/G] rs4978541 9 110451516 [T/C] rs10816556 9 110451579 [T/C] rs10759254 9 110451637 [T/C] rs11789097 9 110451936 [A/G] rs1403856 9 110452511 [T/C] rs1523784 9 110453475 [A/G] rs2049366 9 110454145 [A/G] rs4557764 9 110459321 [A/G] rs10512382 9 110460993 [T/C] rs12685971 9 110462320 [T/C] rs2149998 9 110462930 [T/C] rs7032602 9 110463371 [A/G] rs4979264 9 110466214 [T/G] rs6477589 9 110467351 [A/G] rs6477590 9 110467423 [A/G] rs6477591 9 110467498 [T/C] rs10979018 9 110469181 [T/C] rs1880146 9 110469925 [T/C] rs1411355 9 110472296 [T/C] rs7874022 9 110474940 [A/G] rs11789693 9 110477630 [A/C] rs10979023 9 110477887 [A/G] rs7038436 9 110480149 [A/C] rs7847467 9 110487829 [A/G] rs10217338 9 110488648 [A/G] rs12555298 9 110489551 [A/G] rs6477592 9 110489771 [T/C] rs6477593 9 110494208 [T/C] rs4979291 9 110495044 [A/C] rs7863292 9 110497235 [A/G] rs10759255 9 110497951 [T/C] rs2417804 9 110498273 [T/C] rs12347252 9 110499203 [T/C] rs1851741 9 110501437 [A/G] rs1880143 9 110503765 [T/G] rs944178 9 110504358 [T/C] rs2030641 9 110504472 [A/G] rs10979032 9 110505424 [T/G] rs7037931 9 110509904 [A/G] rs10733564 9 110510862 [T/G] rs7042939 9 110511408 [A/G] rs4978566 9 110511936 [T/C] rs7860653 9 110512551 [T/C] rs10979037 9 110514284 [T/C] rs944172 9 110517794 [T/C] rs10118459 9 110519538 [A/G] rs10512379 9 110520428 [A/G] rs12684481 9 110520534 [T/C] rs7040755 9 110522741 [A/G] rs12554139 9 110529087 [T/C] rs10759257 9 110531496 [T/C] rs2140483 9 110532522 [A/C] rs7028227 9 110534010 [T/C] rs1467311 9 110536932 [A/G] rs1411357 9 110542327 [T/G] rs1330150 9 110544407 [A/G] rs17625789 9 110544732 [A/G] rs4979374 9 110544998 [T/G] rs1330147 9 110548764 [T/G] rs953383 9 110551835 [T/C] rs1330146 9 110552239 [A/G] rs10816576 9 110553667 [A/G] rs1360257 9 110556602 [A/C] rs1411356 9 110557377 [A/G] rs10979062 9 110564032 [A/G] rs12339041 9 110570206 [A/C] rs7028182 9 110571327 [T/G] rs9632903 9 110571952 [T/C] rs7848776 9 110573303 [T/C] rs10121193 9 110581046 [A/G] rs10733565 9 110587368 [T/C] rs7875395 9 110587889 [T/C] rs10979066 9 110597519 [A/G] rs7868096 9 110610987 [A/G] rs7018799 9 110612674 [A/G] rs4979494 9 110615884 [A/G] rs10979075 9 110618805 [T/C] rs4978629 9 110628820 [T/C] rs1929281 9 110632626 [A/G] rs11794699 9 110632874 [A/G] rs10759261 9 110635349 [A/G] rs10816581 9 110635883 [T/C] rs7852099 9 110637432 [A/C] rs7045461 9 110642014 [A/G] rs7045297 9 110642150 [A/G] rs7021395 9 110645412 [T/C] rs10979082 9 110646522 [A/C] rs12335733 9 110650284 [A/G] rs944472 9 110657726 [A/G] rs1929273 9 110658115 [A/G] rs34048749 9 110660983 [A/G] rs10759262 9 110663574 [A/C] rs1929276 9 110666409 [A/G] rs12352069 9 110668222 [T/C] rs1929278 9 110668683 [A/G] rs4978649 9 110677097 [T/C] rs12348520 9 110683074 [A/G] rs7020351 9 110688674 [T/C] rs1339764 9 110688738 [A/G] rs2039802 9 110688855 [T/G] rs11790225 9 110690301 [T/C] rs1361369 9 110694926 [A/C] rs950143 9 110695062 [A/C] rs1361368 9 110696206 [A/G] rs10816591 9 110700994 [A/G] rs6477606 9 110702554 [A/G] rs1888618 9 110702983 [T/C] rs1888619 9 110703410 [A/G] rs12376694 9 110703980 [T/C] rs6477608 9 110705646 [A/G] rs10512375 9 110707050 [T/C] rs7026539 9 110707964 [T/C] rs10521087 9 110709587 [A/G] rs10739251 9 110710767 [A/C] rs10979125 9 110712028 [A/G] rs10979126 9 110712165 [A/G] rs1888621 9 110716274 [T/C] rs9792589 9 110724246 [A/G] rs10979136 9 110725754 [T/C] rs2709418 9 110729131 [A/G] rs1554279 9 110729237 [T/C] rs10979145 9 110731392 [T/C] rs13288508 9 110732326 [T/C] rs498924 9 110732838 [A/C] rs560104 9 110734905 [T/C] rs1703007 9 110735353 [T/C] rs10120991 9 110735536 [A/G] rs10512374 9 110735564 [T/C] rs1703008 9 110736719 [A/G] rs7038277 9 110736854 [T/C] rs1769657 9 110736914 [T/C] rs10521086 9 110738027 [A/G] rs10979150 9 110742521 [A/G] rs10124568 9 110743292 [A/G] rs687658 9 110743573 [T/C] rs10119946 9 110744722 [A/G] rs7029391 9 110751144 [A/G] rs592069 9 110751734 [A/G] rs1009813 9 110752106 [A/G] rs1934419 9 110754102 [T/C] rs1769652 9 110754778 [A/G] rs10979157 9 110757887 [T/C] rs673985 9 110759922 [A/G] rs4979619 9 110760598 [T/C] rs12347482 9 110761427 [T/G] rs12236795 9 110761513 [T/C] rs7341756 9 110762725 [A/G] rs10512368 9 110783036 [A/G] rs7869206 9 110787286 [A/G] rs12551076 9 110787730 [A/G] rs10816618 9 110801608 [A/C] rs1914513 9 110803324 [A/G] rs10816621 9 110808571 [T/C] rs10979181 9 110811668 [T/C] rs4978343 9 110820132 [T/G] rs10979183 9 110821050 [T/C] rs10512367 9 110826460 [T/C] rs13289116 9 110829012 [A/G] rs13291052 9 110832584 [A/G] rs10816625 9 110837073 [A/G] rs7042321 9 110841593 [A/G] rs10979187 9 110843272 [T/C] rs10816626 9 110843426 [T/C] rs10979189 9 110843804 [A/G] rs10118883 9 110843927 [A/G] rs12006421 9 110844942 [T/C] rs10512366 9 110850146 [A/G] rs7875633 9 110852176 [T/G] rs10120248 9 110857507 [A/G] rs1434851 9 110857960 [A/G] rs10979206 9 110860513 [T/C] rs1831590 9 110864014 [A/G] rs7024830 9 110867734 [A/G] rs10120623 9 110868532 [A/G] rs1412436 9 110868550 [T/C] rs10979214 9 110871414 [T/C] rs10124038 9 110872527 [A/G] rs10816631 9 110874194 [T/C] rs10979217 9 110875895 [A/G] rs837983 9 110881453 [T/C] rs667052 9 110882390 [T/C] rs630965 9 110885479 [T/C] rs1025572 9 110887234 [T/G] rs580018 9 110887934 [T/C] rs7870781 9 110891494 [T/C] rs10979227 9 110893829 [T/C] rs516327 9 110896340 [A/G] rs595811 9 110896828 [A/G] rs7863999 9 110901598 [T/C] rs567032 9 110905570 [A/G] rs665556 9 110907467 [T/C] rs10512364 9 110911316 [A/G] rs566510 9 110911435 [T/C] rs614851 9 110917627 [A/G] rs4542003 9 110923018 [T/C] rs525803 9 110923883 [T/C] rs7025273 9 110926037 [A/G] rs687992 9 110929030 [A/G] rs12376560 9 110938366 [T/C] rs637635 9 110939597 [A/G] rs503238 9 110940013 [T/C] rs666303 9 110941390 [T/C] rs10979263 9 110943815 [T/C] rs10759273 9 110946296 [A/G] rs559836 9 110946380 [T/C] rs553333 9 110947155 [T/C] rs10116029 9 110948195 [T/C] rs10113991 9 110950667 [T/G] rs10512362 9 110953051 [A/G] rs13287243 9 110954627 [T/C] rs550891 9 110954663 [T/G] rs556399 9 110955288 [A/G] rs569859 9 110959588 [A/G] rs838012 9 110969777 [A/G] rs10512361 9 110974998 [T/C] rs655655 9 110977335 [T/C] rs7026619 9 110978841 [A/C] rs672586 9 110978859 [A/G] rs2571504 9 110981431 [T/C] rs519144 9 110986403 [A/G] rs10979283 9 110987236 [T/G] rs837999 9 110989319 [A/C] rs868895 9 110989880 [T/G] rs1888913 9 110990323 [T/G] rs1819463 9 110991069 [T/C] rs10122058 9 111000640 [A/C] rs4644328 9 111008699 [T/C] rs13302091 9 111014118 [T/C] rs7043626 9 111018343 [T/G] rs7030526 9 111022525 [A/G] rs10739255 9 111023899 [T/C] rs3117888 9 111027827 [T/C] rs1330591 9 111029103 [T/C] rs2778255 9 111032311 [A/G] rs16912823 9 111033028 [T/C] rs1323397 9 111034788 [A/G] rs1575450 9 111037295 [A/G] rs12004427 9 111042233 [T/C] rs1323377 9 111043009 [T/C] rs10979301 9 111044933 [T/C] rs7029971 9 111044950 [T/G] rs7021201 9 111050366 [T/C] rs12353336 9 111050810 [T/C] rs10117055 9 111051418 [T/C] rs1570504 9 111054809 [A/C] rs1323380 9 111060921 [T/G] rs10816656 9 111062515 [A/G] rs17543333 9 111066833 [T/G] rs7854538 9 111068986 [A/C] rs12349823 9 111072668 [T/C] rs10816658 9 111074108 [T/C] rs10283642 9 111074243 [A/G] rs942137 9 111074896 [T/C] rs7033347 9 111077062 [T/C] rs4978345 9 111082271 [T/G] rs7860612 9 111085981 [T/C] rs7031855 9 111098115 [A/G] rs1323391 9 111100388 [T/C] rs1323396 9 111107191 [A/C] rs7045550 9 111109673 [T/C] rs2146786 9 111114705 [A/G] rs10979321 9 111114728 [T/C] rs16912988 9 111116866 [A/G] rs12338469 9 111118695 [T/C] rs10979326 9 111120353 [A/C] rs10979327 9 111120695 [T/G] rs16913005 9 111122112 [T/C] rs12379749 9 111123697 [T/C] rs16913008 9 111128013 [A/C] rs7043971 9 111130749 [T/C] rs1885968 9 111140133 [A/C] rs1323719 9 111142265 [A/G] rs10115131 9 111143660 [T/C] rs10816666 9 111151700 [T/C] rs10114425 9 111152200 [T/C] rs16913038 9 111153825 [T/C] rs16913043 9 111154361 [T/C] rs657749 9 111160260 [A/G] rs640278 9 111161855 [A/G] rs625616 9 111162866 [A/G] rs1211179 9 111163388 [A/G] rs1998537 9 111167197 [T/C] rs10979346 9 111175438 [T/C] rs10979347 9 111175475 [T/G] rs518095 9 111176217 [A/G] rs7856191 9 111180537 [A/G] rs2093677 9 111181099 [A/C] rs2093679 9 111182085 [T/C] rs506707 9 111182146 [T/C] rs539864 9 111197736 [A/G] rs478208 9 111201554 [T/C] rs10979352 9 111202210 [A/G] rs488085 9 111204349 [T/C] rs9644923 9 111230318 [A/G] rs9644924 9 111231987 [A/G] rs11793635 9 111232786 [A/G] rs7859673 9 111234117 [T/C] rs2417865 9 111236780 [T/C] rs7044687 9 111236905 [A/G] rs7039103 9 111238914 [T/C] rs11795133 9 111245848 [A/C] rs1408066 9 111250709 [A/G] rs10979372 9 111259345 [T/G] rs6477655 9 111275801 [T/C] rs9918937 9 111277519 [A/G] rs7042096 9 111279713 [T/C] rs7030851 9 111281164 [A/G] rs10979382 9 111281792 [A/G] rs10979383 9 111282789 [T/C] rs10816679 9 111283188 [T/C] rs7865368 9 111288037 [A/G] rs7852410 9 111291784 [T/G] rs7018616 9 111295630 [A/G] rs7044959 9 111302146 [A/G] rs4978700 9 111311096 [A/G] rs17198838 9 111313309 [T/G] rs16913269 9 111315303 [A/C] rs10979398 9 111315597 [A/G] rs16913282 9 111318495 [A/G] rs16913284 9 111319491 [T/C] rs12349538 9 111321154 [A/G] rs7856330 9 111322964 [A/G] rs871424 9 111324602 [T/C] rs7858857 9 111334514 [T/C] rs10979405 9 111335268 [T/C] rs10217573 9 111342144 [A/G] rs10217224 9 111342197 [T/G] rs1930100 9 111345751 [T/G] rs4552986 9 111345810 [T/C] rs7848857 9 111351436 [A/G] rs4978715 9 111359745 [A/C] rs1930111 9 111360801 [T/G] rs16913324 9 111362601 [A/G] rs1930108 9 111367630 [A/G] rs4623515 9 111367795 [A/G] rs959244 9 111368151 [T/C] rs4978717 9 111369668 [A/C] rs4978718 9 111369823 [T/C] rs11795397 9 111369840 [T/C] rs7857549 9 111370795 [A/C] rs10816689 9 111372759 [A/C] rs7851754 9 111376151 [T/G] rs7027855 9 111376977 [T/C] rs12340315 9 111379252 [A/G] rs1958943 9 111379330 [T/C] rs12336075 9 111382775 [A/G] rs16913355 9 111385834 [A/G] rs10979414 9 111387353 [A/G] rs13289732 9 111387462 [A/G] rs4978359 9 111388183 [A/G] rs4978720 9 111389865 [A/G] rs10979420 9 111396522 [A/G] rs10115769 9 111396742 [A/G] rs4978360 9 111397766 [A/G] rs13302880 9 111400131 [A/C] rs4978721 9 111401766 [T/C] rs4412431 9 111402410 [T/G] rs10816693 9 111404834 [T/G] rs10979424 9 111405228 [T/C] rs10979427 9 111408094 [T/C] rs1873764 9 111409524 [T/C] rs7865339 9 111413448 [A/G] rs7018492 9 111413719 [A/G] rs10979429 9 111414999 [T/G] rs937160 9 111417991 [A/G] rs3983541 9 111420155 [T/G] rs1319976 9 111423688 [A/G] rs2417919 9 111427754 [T/C] rs7034647 9 111429924 [A/G] rs2417921 9 111430589 [T/C] rs11794727 9 111435632 [A/G] rs10122249 9 111442761 [A/G] rs4978725 9 111446046 [T/C] rs13286509 9 111453191 [T/C] rs10512385 9 111455575 [A/G] rs7874723 9 111455892 [A/C] rs10759298 9 111460075 [T/G] rs7031739 9 111467834 [T/C] rs1556950 9 111468234 [T/C] rs6477669 9 111469933 [A/G] rs13299079 9 111481932 [T/C] rs10979455 9 111484899 [A/G] rs10122805 9 111485851 [T/C] rs1934460 9 111498383 [A/G] rs10816707 9 111504523 [A/G] rs4978734 9 111507261 [T/C] rs10979466 9 111509986 [T/C] rs2039810 9 111511670 [A/G] rs10816710 9 111511992 [T/C] rs10759310 9 111518150 [T/G] rs11789156 9 111520844 [A/G] rs4978735 9 111522389 [A/C] rs1538658 9 111523941 [T/C] rs4978364 9 111524704 [T/C] rs9886734 9 111528013 [A/G] rs10118705 9 111528780 [A/G] rs10739269 9 111538497 [A/G] rs870913 9 111540653 [T/C] rs1416900 9 111542647 [T/G] rs10816720 9 111542950 [A/C] rs10448261 9 111543572 [A/G] rs7019881 9 111547599 [T/G] rs7034453 9 111547669 [T/C] rs7020124 9 111547818 [T/C] rs10118169 9 111550543 [A/G] rs7047863 9 111550862 [A/G] rs10979489 9 111551344 [T/G] rs10512387 9 111551724 [A/C] rs1416898 9 111552022 [T/C] rs12377816 9 111552269 [T/C] rs10979496 9 111555057 [A/G] rs10979502 9 111563327 [T/C] rs12351756 9 111563554 [T/C] rs10979504 9 111563577 [T/C] rs16913553 9 111563971 [T/C] rs10979505 9 111564077 [T/C] rs10979523 9 111577140 [A/G] rs10816732 9 111584123 [T/C] rs6477683 9 111592442 [A/C] rs17199679 9 111593080 [A/G] rs10816733 9 111594273 [A/G] rs10816735 9 111595187 [T/C] rs1417712 9 111596085 [T/C] rs2039923 9 111598970 [T/C] rs4354381 9 111599066 [A/G] rs16913584 9 111603106 [A/G] rs10979545 9 111604933 [A/G] rs12552409 9 111605283 [T/C] rs7034770 9 111605612 [T/C] rs7024768 9 111606792 [T/G] rs7039521 9 111606875 [A/G] rs1539028 9 111608280 [A/G] rs4978368 9 111612990 [T/C] rs10979554 9 111613145 [A/C] rs10121739 9 111614992 [A/G] rs3750467 9 111617341 [A/G] NM_006686 ACTL7B EXON Synonymous_T290T rs6415805 9 111619707 [A/G] rs10816744 9 111620728 [A/G] rs10979564 9 111621439 [A/G] rs11794127 9 111622975 [A/G] rs4978746 9 111623055 [T/C] rs9299164 9 111623941 [T/C] rs10979570 9 111623989 [A/G] rs3739693 9 111625259 [A/G] NM_006687 ACTL7A EXON Synonymous_V219V rs7872727 9 111626090 [A/G] rs12351317 9 111628667 [T/C] rs10979579 9 111633720 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs2027433 9 111637304 [T/G] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs1981268 9 111637331 [A/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs7874795 9 111638684 [A/G] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs10435834 9 111640631 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs10435835 9 111640667 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs2275496 9 111641627 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs1538660 9 111641825 [A/G] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 EXON Missense_P809L,Missense_P1158L,Missense_P1044L rs7874280 9 111642535 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs10117384 9 111645198 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs6477685 9 111646406 [A/G] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs4978374 9 111646983 [A/G] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs10816756 9 111647581 [A/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs10816758 9 111648732 [A/G] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs10120358 9 111650007 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs10117105 9 111650048 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs3204145 9 111651620 [T/A] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 EXON Missense_C723S,Missense_C1072S,Missense_C958S rs12344049 9 111652477 [A/G] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs3780512 9 111654395 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs2275626 9 111659021 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs10979599 9 111659277 [T/G] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 EXON Missense_T499N,Missense_T848N,Missense_T734N rs2230793 9 111659483 [T/G] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 EXON Missense_I467L,Missense_I816L,Missense_I702L rs10979601 9 111660851 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 EXON Missense_G416E,Missense_G765E,Missense_G651E rs4978760 9 111661150 [A/G] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs10979604 9 111663754 [A/G] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 EXON Synonymous_T306T,Synonymous_T655T,Synonymous_T541T rs10979605 9 111663793 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 EXON Synonymous_T293T,Synonymous_T642T,Synonymous_T528T rs3818932 9 111664178 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs838827 9 111668652 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 EXON Missense_R176Q,Missense_R525Q,Missense_R411Q rs838826 9 111670100 [A/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs11791215 9 111673580 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs1772043 9 111678016 [A/G] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs12340246 9 111679872 [A/G] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 EXON Silent,Synonymous_L273L,Synonymous_L159L rs17853166 9 111679940 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 EXON Silent,Missense_S251G,Missense_S137G rs2275635 9 111688767 [T/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 Silent,Silent,Silent rs3737311 9 111692144 [A/G] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 EXON Silent,Missense_R70C,Silent rs2275640 9 111696214 [A/C] NM_001330749,NM_003640,NM_001318360 ELP1,ELP1,ELP1 EXON Silent,Silent,Silent rs1759842 9 111697054 [A/G] NM_017832 FAM206A Silent rs1616727 9 111697427 [A/G] NM_017832 FAM206A Silent rs13299328 9 111703561 [T/C] rs28361184 9 111704909 [A/G] NM_001286974,NM_003798 CTNNAL1,CTNNAL1 EXON Silent,Silent rs2289480 9 111705501 [A/C] NM_001286974,NM_003798 CTNNAL1,CTNNAL1 Silent,Silent rs10979624 9 111718063 [T/C] NM_001286974,NM_003798 CTNNAL1,CTNNAL1 Silent,Silent rs2304784 9 111718325 [T/C] NM_001286974,NM_003798 CTNNAL1,CTNNAL1 Silent,Silent rs16913731 9 111726070 [A/G] NM_001286974,NM_003798 CTNNAL1,CTNNAL1 Silent,Silent rs10979638 9 111744771 [A/C] NM_001286974,NM_003798 CTNNAL1,CTNNAL1 Silent,Silent rs866311 9 111746097 [T/G] NM_001286974,NM_003798 CTNNAL1,CTNNAL1 Silent,Silent rs4978381 9 111761229 [T/C] NM_001286974,NM_003798 CTNNAL1,CTNNAL1 Silent,Silent rs12555920 9 111765737 [T/C] NM_001286974,NM_003798 CTNNAL1,CTNNAL1 Silent,Silent rs11788284 9 111768728 [T/C] NM_001286974,NM_003798 CTNNAL1,CTNNAL1 Silent,Silent rs10816766 9 111774393 [T/C] NM_001286974,NM_003798 CTNNAL1,CTNNAL1 Silent,Silent rs1333344 9 111776224 [A/G] rs7776 9 111782531 [T/G] NM_032012 TMEM245 EXON Silent rs10816767 9 111782670 [A/G] NM_032012 TMEM245 EXON Silent rs10979660 9 111790432 [T/C] NM_032012 TMEM245 Silent rs7852550 9 111795565 [T/C] NM_032012 TMEM245 Silent rs2256253 9 111798751 [T/C] NM_032012 TMEM245 Silent rs489283 9 111799369 [T/G] NM_032012 TMEM245 Silent rs534286 9 111800234 [A/G] NM_032012 TMEM245 Silent rs3750453 9 111801344 [A/G] NM_032012 TMEM245 Silent rs12341137 9 111802146 [T/C] NM_032012 TMEM245 Silent rs12552449 9 111802246 [T/G] NM_032012 TMEM245 Silent rs646234 9 111807394 [A/G] NM_032012 TMEM245 Silent rs614253 9 111812825 [T/C] NM_032012 TMEM245 Silent rs1003346 9 111815340 [A/C] NM_032012 TMEM245 Silent rs11787869 9 111831600 [A/G] NM_032012 TMEM245 Silent rs7855980 9 111834983 [A/G] NM_032012 TMEM245 Silent rs10979681 9 111837094 [A/G] NM_032012 TMEM245 Silent rs523340 9 111854246 [A/G] NM_032012 TMEM245 Silent rs16913811 9 111861345 [T/C] NM_032012 TMEM245 Silent rs2271878 9 111868885 [A/G] NM_032012 TMEM245 EXON Synonymous_S234S rs2805888 9 111880736 [T/C] NM_032012 TMEM245 Silent rs6825 9 111881927 [T/C] NM_032012 TMEM245 EXON Synonymous_L89L rs10816772 9 111885869 [T/C] rs17627977 9 111886177 [A/C] rs12379316 9 111886575 [A/C] rs4978770 9 111887219 [T/G] rs1416957 9 111890197 [T/C] rs2417976 9 111890349 [A/C] rs11794020 9 111899198 [T/C] NM_014334 FRRS1L EXON Silent rs10759329 9 111899928 [A/G] NM_014334 FRRS1L Silent rs10979712 9 111915474 [T/C] NM_014334 FRRS1L Silent rs6477693 9 111918365 [A/C] NM_014334 FRRS1L Silent rs10979720 9 111920745 [A/C] NM_014334 FRRS1L Silent rs4978774 9 111925315 [A/G] NM_014334 FRRS1L Silent rs7468610 9 111928136 [T/C] NM_014334 FRRS1L Silent rs2139350 9 111928593 [A/G] NM_014334 FRRS1L Silent rs6477694 9 111932342 [T/C] rs10759332 9 111934261 [A/G] NM_019114 EPB41L4B EXON Silent rs10979727 9 111936788 [T/C] NM_019114 EPB41L4B EXON Silent rs10119402 9 111938125 [T/G] NM_019114 EPB41L4B Silent rs10979731 9 111940346 [T/C] NM_019114 EPB41L4B Silent rs885506 9 111942070 [A/G] NM_019114 EPB41L4B Silent rs10816777 9 111942504 [T/C] NM_019114 EPB41L4B Silent rs16936344 9 111944009 [T/C] NM_019114 EPB41L4B Silent rs3750450 9 111945049 [T/G] NM_019114 EPB41L4B EXON Missense_N816T rs3750449 9 111945260 [T/C] NM_019114 EPB41L4B Silent rs3983526 9 111945992 [T/C] NM_019114 EPB41L4B Silent rs10816779 9 111946103 [A/G] NM_019114 EPB41L4B Silent rs10116353 9 111950088 [T/G] NM_019114 EPB41L4B Silent rs12346595 9 111955592 [T/C] NM_019114 EPB41L4B Silent rs6415807 9 111958345 [A/G] NM_019114 EPB41L4B Silent rs7875754 9 111961389 [T/C] NM_019114 EPB41L4B Silent rs7021903 9 111963923 [T/C] NM_019114 EPB41L4B Silent rs4978780 9 111967572 [T/C] NM_019114 EPB41L4B Silent rs7044279 9 111969201 [T/G] NM_019114 EPB41L4B Silent rs10739274 9 111972423 [T/G] NM_019114 EPB41L4B Silent rs10979749 9 111972497 [A/G] NM_019114 EPB41L4B Silent rs7858370 9 111973020 [A/G] NM_019114 EPB41L4B Silent rs12336868 9 111973466 [A/C] NM_019114 EPB41L4B Silent rs4978783 9 111978049 [A/C] NM_019114 EPB41L4B Silent rs7860076 9 111979807 [T/C] NM_019114 EPB41L4B Silent rs4483229 9 111980234 [A/G] NM_019114 EPB41L4B Silent rs10979760 9 111984614 [T/C] NM_019114 EPB41L4B Silent rs1879069 9 111991700 [T/C] NM_019114 EPB41L4B Silent rs2012370 9 111991981 [T/C] NM_019114 EPB41L4B Silent rs10816789 9 111992509 [T/C] NM_019114 EPB41L4B Silent rs3849111 9 111994722 [A/C] NM_019114 EPB41L4B Silent rs17200841 9 111996188 [T/C] NM_019114 EPB41L4B Silent rs1470125 9 112012488 [A/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs745388 9 112020668 [T/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs750723 9 112021585 [T/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs893918 9 112021708 [T/G] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs2004094 9 112021852 [T/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs746417 9 112021988 [A/G] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs1837549 9 112024242 [T/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs4978787 9 112024496 [T/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs10979783 9 112028096 [T/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs10979785 9 112032220 [T/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs3793555 9 112033697 [A/G] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs3793552 9 112039400 [T/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs4978791 9 112040717 [T/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs10512228 9 112042039 [A/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs10979798 9 112044763 [A/G] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs12337243 9 112048800 [A/G] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs10816797 9 112050060 [T/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs10979808 9 112054525 [A/G] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs10512392 9 112056059 [T/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs10979811 9 112058404 [A/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs12352460 9 112058964 [A/G] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs3793549 9 112062247 [T/G] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs3763640 9 112070162 [T/G] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs7025125 9 112072419 [A/G] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs10122294 9 112074707 [A/G] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs966697 9 112080128 [T/C] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs4978793 9 112081994 [A/G] NM_019114,NM_018424 EPB41L4B,EPB41L4B Silent,Silent rs4978795 9 112089520 [T/G] rs10979826 9 112091175 [T/C] rs12553743 9 112097738 [A/G] rs7047594 9 112098154 [T/G] rs7857376 9 112100958 [A/G] rs7863010 9 112103798 [T/C] rs10979834 9 112103828 [T/C] rs7847955 9 112104111 [A/C] rs7848206 9 112104315 [T/C] rs4292768 9 112104544 [A/C] rs7852279 9 112105331 [T/C] rs12685120 9 112107196 [T/G] rs10979836 9 112107689 [A/G] rs972776 9 112107823 [A/C] rs12115792 9 112108334 [A/G] rs1371786 9 112110035 [T/C] rs10979838 9 112112634 [T/C] rs10759341 9 112121089 [A/G] rs7872998 9 112131222 [T/C] rs12551129 9 112133083 [T/C] rs10979845 9 112135429 [A/G] rs3943672 9 112137099 [T/G] rs17793551 9 112147459 [A/C] NM_001145371,NM_001145370,NR_026918,NM_001145368,NM_002829,NM_001145369,NM_001145372 PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3793569 9 112148314 [A/G] NM_001145371,NM_001145370,NR_026918,NM_001145368,NM_002829,NM_001145369,NM_001145372 PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3793567 9 112149215 [A/G] NM_001145371,NM_001145370,NR_026918,NM_001145368,NM_002829,NM_001145369,NM_001145372 PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3793566 9 112150516 [T/C] NM_001145371,NM_001145370,NR_026918,NM_001145368,NM_002829,NM_001145369,NM_001145372 PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1371787 9 112151349 [T/C] NM_001145371,NM_001145370,NR_026918,NM_001145368,NM_002829,NM_001145369,NM_001145372 PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10816805 9 112152419 [T/G] NM_001145371,NM_001145370,NR_026918,NM_001145368,NM_002829,NM_001145369,NM_001145372 PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10512393 9 112153156 [A/G] NM_001145371,NM_001145370,NR_026918,NM_001145368,NM_002829,NM_001145369,NM_001145372 PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17201409 9 112164045 [A/G] NM_001145371,NM_001145370,NR_026918,NM_001145368,NM_002829,NM_001145369,NM_001145372 PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10816807 9 112165546 [A/C] NM_001145371,NM_001145370,NR_026918,NM_001145368,NM_002829,NM_001145369,NM_001145372 PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7847693 9 112171184 [A/G] NM_001145371,NM_001145370,NR_026918,NM_001145368,NM_002829,NM_001145369,NM_001145372 PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17803052 9 112172674 [T/C] NM_001145371,NM_001145370,NR_026918,NM_001145368,NM_002829,NM_001145369,NM_001145372 PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3 EXON Synonymous_P158P,Synonymous_P269P,Silent,Synonymous_P400P,Synonymous_P445P,Synonymous_P314P,Synonymous_P113P rs2274785 9 112190884 [A/G] NM_001145371,NM_001145370,NM_001145368,NM_002829,NM_001145369,NM_001145372 PTPN3,PTPN3,PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent,Silent,Silent rs3793532 9 112192338 [A/C] NM_001145370,NM_001145368,NM_002829,NM_001145369 PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent rs7873088 9 112193021 [T/C] NM_001145370,NM_001145368,NM_002829,NM_001145369 PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent rs10979861 9 112197634 [T/C] NM_001145370,NM_001145368,NM_002829,NM_001145369 PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent rs4978809 9 112199146 [A/G] NM_001145370,NM_001145368,NM_002829,NM_001145369 PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent rs17793718 9 112199506 [A/G] NM_001145370,NM_001145368,NM_002829,NM_001145369 PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent rs16914146 9 112201603 [T/C] NM_001145370,NM_001145368,NM_002829,NM_001145369 PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent rs17793748 9 112203625 [T/C] NM_001145370,NM_001145368,NM_002829,NM_001145369 PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent rs1108496 9 112207341 [T/C] NM_001145370,NM_001145368,NM_002829,NM_001145369 PTPN3,PTPN3,PTPN3,PTPN3 Silent,Silent,Silent,Silent rs4978810 9 112218035 [T/C] NM_001145368,NM_002829 PTPN3,PTPN3 Silent,Silent rs7041037 9 112218403 [T/C] NM_001145368,NM_002829 PTPN3,PTPN3 Silent,Silent rs10816813 9 112218841 [T/G] NM_001145368,NM_002829 PTPN3,PTPN3 Silent,Silent rs7033652 9 112220503 [T/C] NM_001145368,NM_002829 PTPN3,PTPN3 Silent,Silent rs7850860 9 112221052 [T/C] NM_001145368,NM_002829 PTPN3,PTPN3 Silent,Silent rs7046039 9 112236879 [T/C] NM_001145368,NM_002829 PTPN3,PTPN3 Silent,Silent rs10979884 9 112237679 [T/C] NM_001145368,NM_002829 PTPN3,PTPN3 Silent,Silent rs10512395 9 112243321 [T/C] NM_001145368,NM_002829 PTPN3,PTPN3 Silent,Silent rs10759343 9 112244438 [T/C] NM_001145368,NM_002829 PTPN3,PTPN3 Silent,Silent rs4978813 9 112251563 [A/G] NM_001145368,NM_002829 PTPN3,PTPN3 Silent,Silent rs10979889 9 112253555 [T/C] NM_001145368,NM_002829 PTPN3,PTPN3 Silent,Silent rs4978394 9 112266667 [A/G] rs4978396 9 112269480 [A/G] rs4978816 9 112271395 [T/C] rs4978817 9 112271805 [T/C] rs10124300 9 112277740 [A/C] rs1109478 9 112281863 [A/G] rs881660 9 112282070 [A/C] rs10119758 9 112284879 [A/G] rs12554939 9 112291281 [T/G] rs9987721 9 112291471 [T/C] rs1999269 9 112294766 [T/C] rs7046565 9 112302220 [T/C] rs1541087 9 112303530 [A/G] rs17201835 9 112303858 [A/G] rs11788069 9 112309305 [A/G] rs10759349 9 112315013 [A/G] rs12554063 9 112317462 [T/C] rs7858161 9 112325051 [A/G] rs10979935 9 112327958 [A/G] rs7032700 9 112337709 [A/C] rs13283237 9 112339759 [A/G] rs10512396 9 112346022 [T/C] rs10512397 9 112346234 [A/G] rs10979955 9 112350261 [T/C] rs7044539 9 112353128 [T/C] rs17794184 9 112355217 [A/C] rs1411683 9 112358656 [A/G] rs746376 9 112365670 [T/C] rs7852886 9 112366444 [A/G] rs4978839 9 112366635 [A/G] rs1169626 9 112366665 [A/G] rs10119049 9 112367107 [A/G] rs6477714 9 112367400 [T/G] rs1576587 9 112370353 [T/G] rs4978842 9 112377352 [T/C] rs7049166 9 112381955 [T/C] rs10123567 9 112382522 [A/G] rs4514053 9 112383305 [T/C] rs10979965 9 112383429 [T/C] rs6477716 9 112390854 [A/G] rs4344152 9 112392697 [T/C] rs7029517 9 112393507 [T/C] rs11791761 9 112394924 [T/G] rs1407393 9 112396529 [A/G] rs1407394 9 112398477 [A/G] rs1358917 9 112398754 [A/G] rs11790056 9 112400897 [T/C] rs10739280 9 112401674 [A/G] rs10979977 9 112401745 [A/G] rs10979978 9 112406744 [T/C] NM_001037293 PALM2 Silent rs7049116 9 112411823 [T/G] NM_001037293 PALM2 Silent rs10979982 9 112413523 [T/C] NM_001037293 PALM2 Silent rs10512398 9 112415744 [A/C] NM_001037293 PALM2 Silent rs16914315 9 112418293 [A/G] NM_001037293 PALM2 Silent rs7026239 9 112419244 [A/G] NM_001037293 PALM2 Silent rs10979990 9 112429319 [T/C] NM_001037293 PALM2 Silent rs7875665 9 112434587 [T/C] NM_001037293 PALM2 Silent rs10979994 9 112438399 [T/C] NM_001037293 PALM2 Silent rs10979996 9 112440123 [A/G] NM_001037293 PALM2 Silent rs4292771 9 112443817 [A/G] NM_001037293 PALM2 Silent rs2146087 9 112444460 [A/G] NM_001037293 PALM2 Silent rs10816855 9 112451003 [T/C] NM_001037293 PALM2 Silent rs713145 9 112453013 [A/G] NM_001037293 PALM2 Silent rs7022805 9 112473382 [A/C] NM_001037293 PALM2 Silent rs2031785 9 112475587 [A/G] NM_001037293 PALM2 Silent rs10980011 9 112477012 [T/C] NM_001037293 PALM2 Silent rs2208704 9 112477726 [A/G] NM_001037293 PALM2 Silent rs239 9 112479083 [T/C] NM_001037293 PALM2 Silent rs1322275 9 112480192 [A/G] NM_001037293 PALM2 Silent rs1571267 9 112483181 [A/C] NM_001037293 PALM2 Silent rs10046850 9 112485888 [A/C] NM_001037293 PALM2 Silent rs9409094 9 112488155 [A/G] NM_001037293 PALM2 Silent rs1322272 9 112492370 [A/G] NM_001037293 PALM2 Silent rs7038221 9 112492485 [T/C] NM_001037293 PALM2 Silent rs12343459 9 112502765 [A/G] NM_001037293 PALM2 Silent rs7848345 9 112508976 [T/G] NM_001037293 PALM2 Silent rs16914480 9 112510562 [T/C] NM_001037293 PALM2 Silent rs10512400 9 112512382 [A/C] NM_001037293 PALM2 Silent rs4111120 9 112513269 [T/C] NM_001037293 PALM2 Silent rs2149002 9 112519888 [A/G] NM_001037293 PALM2 Silent rs2025878 9 112521535 [T/C] NM_001037293 PALM2 Silent rs7028330 9 112525489 [A/G] NM_001037293 PALM2 Silent rs11790000 9 112525766 [T/C] NM_001037293 PALM2 Silent rs7023524 9 112531466 [A/G] NM_001037293 PALM2 Silent rs7023411 9 112531537 [T/C] NM_001037293 PALM2 Silent rs16914500 9 112531693 [T/C] NM_001037293 PALM2 Silent rs2068439 9 112532676 [T/G] NM_001037293 PALM2 Silent rs1327793 9 112534856 [A/G] NM_001037293 PALM2 Silent rs1327794 9 112534910 [A/G] NM_001037293 PALM2 Silent rs7022225 9 112536455 [T/G] NM_001037293 PALM2 Silent rs10115708 9 112539406 [T/C] NM_001037293 PALM2 Silent rs10816866 9 112543228 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs2182815 9 112546308 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs913359 9 112551867 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs1887521 9 112553003 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs13294989 9 112554953 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs13286006 9 112556848 [A/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10980041 9 112556945 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs2209815 9 112561012 [T/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10759367 9 112569588 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10759368 9 112569923 [T/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs730973 9 112574527 [A/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs12003677 9 112576143 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs4295727 9 112578906 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs2795058 9 112579958 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs7032049 9 112583729 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10980070 9 112584723 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs12001151 9 112589201 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs2418050 9 112589454 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10733573 9 112591526 [T/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs7867595 9 112592855 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10816891 9 112593531 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs2025875 9 112596911 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10980082 9 112606655 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs2769151 9 112608710 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10816897 9 112610830 [A/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs2004426 9 112611749 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs1077760 9 112612553 [T/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs17794822 9 112613140 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10980086 9 112614108 [A/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10980089 9 112618755 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs12338023 9 112620371 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs2769143 9 112621077 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs7031808 9 112621178 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs7875145 9 112621234 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs2769145 9 112621761 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10980096 9 112625522 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs11792458 9 112628478 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs7044189 9 112629397 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10980100 9 112630762 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs7042517 9 112632327 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs2479314 9 112632977 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs16914570 9 112634210 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10759382 9 112634640 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs7040294 9 112636653 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs1475433 9 112638250 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs16914573 9 112638465 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs9409096 9 112640311 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs13283300 9 112640616 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs16914575 9 112641489 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs9408826 9 112641903 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10816904 9 112642756 [T/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs1341983 9 112645868 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs10283686 9 112648964 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs12343568 9 112656046 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs6477730 9 112660775 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs7849107 9 112660803 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs2095094 9 112661908 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs1108832 9 112662354 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs4978408 9 112662634 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs1981035 9 112663125 [T/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs877640 9 112663525 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs17806031 9 112667903 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs12115781 9 112672877 [A/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs7858354 9 112684039 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs11790499 9 112685300 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs11999319 9 112693360 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs2277146 9 112694486 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs13294193 9 112702544 [T/C] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs7029365 9 112703215 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 Silent,Silent,Silent,Silent rs7035935 9 112706482 [T/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 EXON Silent,Silent,Silent,Silent rs10980119 9 112706888 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 EXON Silent,Silent,Silent,Silent rs3741894 9 112711519 [A/G] NM_001037293,NM_147150,NM_053016,NM_007203 PALM2,PALM2-AKAP2,PALM2,PALM2-AKAP2 EXON Silent,Silent,Silent,Silent rs17806164 9 112715099 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs10120878 9 112717505 [A/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs12003083 9 112722869 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs6477734 9 112728014 [T/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs7020474 9 112731195 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs11794102 9 112732288 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs4978864 9 112734445 [T/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs1930249 9 112735377 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs4978866 9 112735585 [T/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs995294 9 112739344 [T/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs10739286 9 112740024 [T/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs7871446 9 112741697 [T/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs10980133 9 112742786 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs4978411 9 112750411 [T/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs10217743 9 112751482 [T/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs10217567 9 112751649 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs12000943 9 112753883 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs10739287 9 112756545 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs10816913 9 112757373 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs7864336 9 112757584 [A/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs7864442 9 112757604 [A/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs10980136 9 112758187 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs12555129 9 112760293 [T/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs6477736 9 112769632 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs10739288 9 112775268 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs1571260 9 112775738 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs723706 9 112778426 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs7030564 9 112778952 [A/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs10512401 9 112783824 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs10759387 9 112787897 [T/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs7024673 9 112790036 [T/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs260188 9 112791184 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs260194 9 112796113 [A/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs260205 9 112802769 [T/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs10980159 9 112807133 [T/C] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs260215 9 112810330 [T/G] NM_147150,NM_007203 PALM2-AKAP2,PALM2-AKAP2 Silent,Silent rs7043272 9 112811603 [T/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs260218 9 112813375 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs260223 9 112815997 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs2017392 9 112820620 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs541471 9 112823818 [T/C] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs552182 9 112825422 [T/C] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs521883 9 112826429 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs539817 9 112830219 [T/C] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs12056992 9 112832200 [T/C] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs491533 9 112832326 [T/C] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs481661 9 112839238 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs1752333 9 112845614 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs564321 9 112847897 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs1980874 9 112850080 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs10512402 9 112851492 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs7038399 9 112853511 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs10980199 9 112858901 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs494267 9 112864943 [T/C] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs7026192 9 112868321 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs11788194 9 112869277 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs11790833 9 112873868 [T/C] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs1327775 9 112874767 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs472814 9 112878104 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs525681 9 112879762 [A/C] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs496709 9 112879944 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs4978870 9 112884482 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs17806439 9 112886940 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent rs914355 9 112889315 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs2900505 9 112891853 [T/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs943616 9 112893850 [T/C] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs2418071 9 112896592 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs10980217 9 112897866 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs7039287 9 112898708 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 EXON Missense_C295Y,Missense_C295Y,Missense_C153Y,Missense_C153Y,Missense_C64Y rs3739457 9 112899534 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 EXON Synonymous_A570A,Synonymous_A570A,Synonymous_A428A,Synonymous_A428A,Synonymous_A339A rs914358 9 112900199 [T/C] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 EXON Missense_L792S,Missense_L792S,Missense_L650S,Missense_L650S,Missense_L561S rs3739456 9 112900785 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 EXON Synonymous_S987S,Synonymous_S987S,Synonymous_S845S,Synonymous_S845S,Synonymous_S756S rs16914814 9 112908032 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs17203603 9 112914082 [T/C] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs4372077 9 112916400 [T/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs10980226 9 112918217 [A/C] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs10816927 9 112918360 [T/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs10759392 9 112918531 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs7847354 9 112919288 [A/C] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs7023507 9 112920099 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs914359 9 112923119 [T/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs1571780 9 112925906 [T/C] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs10980229 9 112925977 [T/C] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs4978413 9 112929130 [T/C] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 Silent,Silent,Silent,Silent,Silent rs1047469 9 112931646 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 EXON Silent,Silent,Silent,Silent,Silent rs12340651 9 112932182 [A/G] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 EXON Silent,Silent,Silent,Silent,Silent rs4289885 9 112933271 [T/C] NM_147150,NM_007203,NM_001004065,NM_001198656,NM_001136562 PALM2-AKAP2,PALM2-AKAP2,AKAP2,AKAP2,AKAP2 EXON Silent,Silent,Silent,Silent,Silent rs1041482 9 112948620 [A/C] rs7039011 9 112949710 [T/G] rs4978883 9 112950305 [T/C] rs10759396 9 112952005 [A/G] rs10512403 9 112962809 [A/G] NM_001012993 C9orf152 EXON Silent rs17806752 9 112962942 [T/C] NM_001012993 C9orf152 EXON Silent rs10120707 9 112963504 [A/G] NM_001012993 C9orf152 EXON Synonymous_D148D rs4978888 9 112963702 [A/G] NM_001012993 C9orf152 EXON Synonymous_N82N rs4246877 9 112964736 [T/C] NM_001012993 C9orf152 Silent rs7046745 9 112966252 [A/C] NM_001012993 C9orf152 Silent rs4978890 9 112967140 [T/C] NM_001012993 C9orf152 Silent rs4111656 9 112970634 [T/C] rs4314718 9 112973648 [A/G] rs6477748 9 112974847 [T/C] rs7866504 9 112977595 [T/C] rs7851800 9 112978298 [A/G] rs6477749 9 112978727 [A/G] rs10980265 9 112982315 [T/G] rs10816943 9 112983819 [A/G] rs1411922 9 112984666 [A/C] rs1411921 9 112984893 [T/C] rs16914868 9 112989951 [A/G] rs10759402 9 113000213 [T/C] rs2026314 9 113005260 [T/G] rs2026313 9 113005287 [A/G] rs4135233 9 113005317 [T/C] rs4135215 9 113007499 [T/C] NM_003329,NM_001244938 TXN,TXN Silent,Silent rs4135208 9 113009246 [A/G] NM_003329,NM_001244938 TXN,TXN Silent,Silent rs2031760 9 113011039 [T/C] NM_003329,NM_001244938 TXN,TXN Silent,Silent rs4135192 9 113013588 [A/G] NM_003329,NM_001244938 TXN,TXN Silent,Silent rs4135183 9 113015602 [T/C] NM_003329,NM_001244938 TXN,TXN Silent,Silent rs4135179 9 113016000 [T/C] NM_003329,NM_001244938 TXN,TXN Silent,Silent rs4135172 9 113016399 [T/C] NM_003329,NM_001244938 TXN,TXN Silent,Silent rs4135168 9 113016885 [T/C] NM_003329,NM_001244938 TXN,TXN Silent,Silent rs4135167 9 113016916 [T/C] NM_003329,NM_001244938 TXN,TXN Silent,Silent rs1410051 9 113017352 [T/C] NM_003329,NM_001244938 TXN,TXN Silent,Silent rs4135165 9 113017562 [A/G] NM_003329,NM_001244938 TXN,TXN Silent,Silent rs2301241 9 113019508 [A/G] rs3758192 9 113020916 [A/G] rs10733576 9 113022794 [A/G] rs1556047 9 113043999 [A/G] rs10816959 9 113046742 [A/G] rs10980301 9 113050873 [A/C] rs6477754 9 113051296 [T/C] rs7871918 9 113056636 [T/C] rs10739293 9 113058357 [A/G] rs7869617 9 113060439 [A/C] rs10980309 9 113063439 [A/G] rs2274482 9 113065974 [A/G] NM_001364963,NM_001286946,NM_001003936 TXNDC8,TXNDC8,TXNDC8 EXON Silent,Synonymous_D92D,Synonymous_D112D rs10816965 9 113069090 [A/G] NM_001364963,NM_001286946,NM_001003936 TXNDC8,TXNDC8,TXNDC8 Silent,Silent,Silent rs17204340 9 113080316 [T/G] NM_001364963,NM_001286946,NM_001003936 TXNDC8,TXNDC8,TXNDC8 Silent,Silent,Silent rs10980324 9 113081565 [T/C] NM_001364963,NM_001286946,NM_001003936 TXNDC8,TXNDC8,TXNDC8 Silent,Silent,Silent rs1327541 9 113082105 [T/C] NM_001364963,NM_001286946,NM_001003936 TXNDC8,TXNDC8,TXNDC8 Silent,Silent,Silent rs16914942 9 113083182 [A/C] NM_001364963,NM_001286946,NM_001003936 TXNDC8,TXNDC8,TXNDC8 Silent,Silent,Silent rs17807186 9 113085232 [A/G] NM_001364963,NM_001286946,NM_001003936,NM_001286947 TXNDC8,TXNDC8,TXNDC8,TXNDC8 EXON Silent,Silent,Silent,Silent rs10816972 9 113089377 [A/G] NM_001364963,NM_001286946,NM_001003936,NM_001286947 TXNDC8,TXNDC8,TXNDC8,TXNDC8 Silent,Silent,Silent,Silent rs7041938 9 113091523 [T/G] NM_001364963,NM_001286946,NM_001003936,NM_001286947 TXNDC8,TXNDC8,TXNDC8,TXNDC8 EXON Missense_N60H,Silent,Missense_N60H,Silent rs7040502 9 113099591 [T/C] NM_001364963,NM_001286946,NM_001003936,NM_001286947 TXNDC8,TXNDC8,TXNDC8,TXNDC8 Silent,Silent,Silent,Silent rs7040684 9 113099863 [A/C] NM_001364963,NM_001286946,NM_001003936,NM_001286947 TXNDC8,TXNDC8,TXNDC8,TXNDC8 Silent,Silent,Silent,Silent rs6477755 9 113103292 [T/C] rs12686260 9 113103597 [A/G] rs7854346 9 113109166 [A/G] rs7854688 9 113109179 [A/G] rs6477758 9 113110830 [A/G] rs963143 9 113112572 [T/G] rs3949852 9 113114946 [A/G] rs13287615 9 113124417 [A/G] rs17733560 9 113124562 [T/C] rs10816993 9 113125853 [T/G] rs1327532 9 113126314 [A/C] rs12683685 9 113126692 [T/C] rs3739453 9 113127924 [T/G] NM_153366 SVEP1 EXON Silent rs2274483 9 113128505 [A/G] NM_153366 SVEP1 EXON Silent rs17204533 9 113132221 [A/G] NM_153366 SVEP1 EXON Missense_T3559M rs10816998 9 113133741 [A/G] NM_153366 SVEP1 Silent rs1327535 9 113136177 [T/G] NM_153366 SVEP1 Silent rs11791314 9 113141959 [T/C] NM_153366 SVEP1 Silent rs12686142 9 113147203 [T/G] NM_153366 SVEP1 Silent rs7855526 9 113147855 [T/G] NM_153366 SVEP1 Silent rs2255007 9 113149952 [T/C] NM_153366 SVEP1 Silent rs7847265 9 113153159 [T/C] NM_153366 SVEP1 Silent rs10739300 9 113155541 [T/C] NM_153366 SVEP1 Silent rs13294114 9 113162199 [A/G] NM_153366 SVEP1 Silent rs1887457 9 113162304 [T/G] NM_153366 SVEP1 Silent rs1410048 9 113163239 [A/C] NM_153366 SVEP1 EXON Synonymous_V3239V rs12348838 9 113167003 [A/C] NM_153366 SVEP1 Silent rs1327537 9 113168073 [A/C] NM_153366 SVEP1 Silent rs2281937 9 113169126 [A/G] NM_153366 SVEP1 EXON Synonymous_H2918H rs7030192 9 113169631 [A/G] NM_153366 SVEP1 EXON Missense_A2750V rs16914997 9 113171262 [A/G] NM_153366 SVEP1 Silent rs7027372 9 113176113 [T/C] NM_153366 SVEP1 Silent rs4475572 9 113177324 [T/C] NM_153366 SVEP1 Silent rs1410050 9 113188572 [T/C] NM_153366 SVEP1 Silent rs2254168 9 113189213 [T/C] NM_153366 SVEP1 Silent rs17204832 9 113189988 [T/C] NM_153366 SVEP1 EXON Missense_R1953K rs3739450 9 113192427 [T/C] NM_153366 SVEP1 Silent rs6477769 9 113193574 [T/C] NM_153366 SVEP1 Silent rs4545168 9 113194686 [T/C] NM_153366 SVEP1 Silent rs7852962 9 113196733 [A/C] NM_153366 SVEP1 EXON Missense_L1648V rs7042161 9 113197263 [T/C] NM_153366 SVEP1 Silent rs7848767 9 113202831 [T/C] NM_153366 SVEP1 Silent rs7864433 9 113204681 [A/G] NM_153366 SVEP1 Silent rs7863519 9 113208250 [T/G] NM_153366 SVEP1 EXON Missense_M1444L rs7851366 9 113208581 [T/C] NM_153366 SVEP1 Silent rs1889323 9 113209195 [T/G] NM_153366 SVEP1 EXON Missense_K1416Q rs4557772 9 113211216 [A/G] NM_153366 SVEP1 Silent rs10081633 9 113215792 [T/C] NM_153366 SVEP1 Silent rs7035805 9 113217123 [A/C] NM_153366 SVEP1 Silent rs7875113 9 113219779 [A/C] NM_153366 SVEP1 Silent rs7038903 9 113221247 [T/C] NM_153366 SVEP1 EXON Missense_I1157V rs7869377 9 113227531 [T/G] NM_153366 SVEP1 Silent rs17806765 9 113229411 [A/C] NM_153366 SVEP1 Silent rs10817025 9 113234507 [T/C] NM_153366 SVEP1 EXON Missense_K899R rs10512405 9 113236797 [T/C] NM_153366 SVEP1 Silent rs10817026 9 113239268 [T/C] NM_153366 SVEP1 Silent rs7028791 9 113240481 [T/C] NM_153366 SVEP1 Silent rs12115783 9 113244624 [A/G] NM_153366 SVEP1 Silent rs1931304 9 113246386 [A/G] NM_153366 SVEP1 Silent rs10739303 9 113250699 [A/G] NM_153366 SVEP1 Silent rs4399003 9 113252246 [T/C] NM_153366 SVEP1 Silent rs4978934 9 113254704 [T/C] NM_153366 SVEP1 Silent rs13283529 9 113255402 [A/G] NM_153366 SVEP1 Silent rs1889325 9 113255544 [A/G] NM_153366 SVEP1 Silent rs7021157 9 113256301 [A/G] NM_153366 SVEP1 Silent rs10817033 9 113259152 [T/G] NM_153366 SVEP1 EXON Missense_Q581H rs3737156 9 113261433 [T/C] NM_153366 SVEP1 EXON Synonymous_T523T rs872665 9 113261483 [T/C] NM_153366 SVEP1 EXON Missense_V507I rs872666 9 113261645 [T/C] NM_153366 SVEP1 Silent rs10980412 9 113265860 [A/C] NM_153366 SVEP1 Silent rs7046184 9 113267399 [T/C] NM_153366 SVEP1 Silent rs4427239 9 113270601 [A/G] NM_153366 SVEP1 Silent rs10980418 9 113273768 [A/C] NM_153366 SVEP1 Silent rs10980419 9 113275227 [T/C] NM_153366 SVEP1 EXON Missense_G428S rs3818764 9 113276356 [G/C] NM_153366 SVEP1 EXON Missense_G332A rs12346753 9 113278199 [T/C] NM_153366 SVEP1 Silent rs4403484 9 113279114 [A/G] NM_153366 SVEP1 Silent rs12553191 9 113281255 [T/C] NM_153366 SVEP1 Silent rs10980424 9 113282064 [T/G] NM_153366 SVEP1 Silent rs1889329 9 113283373 [T/C] NM_153366 SVEP1 Silent rs10980428 9 113287555 [T/C] NM_153366 SVEP1 Silent rs4521831 9 113291642 [A/G] NM_153366 SVEP1 Silent rs10759440 9 113300206 [T/C] NM_153366 SVEP1 Silent rs1889321 9 113300835 [T/C] NM_153366 SVEP1 Silent rs955833 9 113309263 [T/G] NM_153366 SVEP1 Silent rs7035502 9 113311710 [A/G] NM_153366 SVEP1 Silent rs10980438 9 113313187 [A/C] NM_153366 SVEP1 Silent rs16915122 9 113313503 [T/C] NM_153366 SVEP1 Silent rs10980439 9 113316224 [T/C] NM_153366 SVEP1 Silent rs2991364 9 113316793 [T/C] NM_153366 SVEP1 Silent rs3010808 9 113319516 [A/G] NM_153366 SVEP1 Silent rs4978937 9 113329058 [T/C] NM_153366 SVEP1 Silent rs11788554 9 113331428 [A/G] NM_153366 SVEP1 Silent rs10980451 9 113332268 [T/C] NM_153366 SVEP1 Silent rs7853273 9 113343006 [T/C] rs4978938 9 113343555 [T/C] rs16915134 9 113345800 [A/G] rs12340257 9 113355719 [T/C] rs10817044 9 113360859 [T/C] rs4978943 9 113364308 [T/C] rs12236915 9 113364464 [A/G] rs10817045 9 113366508 [A/G] rs10817046 9 113366597 [A/G] rs10980480 9 113366974 [T/C] rs10980481 9 113367300 [A/G] rs7875689 9 113368085 [T/C] rs4978949 9 113371069 [A/G] rs10817051 9 113372027 [A/G] rs4302915 9 113374865 [T/G] rs4422837 9 113374973 [A/G] rs10817056 9 113378789 [T/C] rs12238269 9 113380437 [T/C] rs4509410 9 113386179 [T/C] rs10817061 9 113388632 [A/C] rs13302218 9 113390612 [A/G] rs6477778 9 113392182 [T/G] rs6477780 9 113393012 [T/C] rs4978951 9 113398561 [A/C] rs3001115 9 113403846 [T/C] rs3001116 9 113404293 [T/C] rs16915239 9 113409839 [A/C] rs3010804 9 113422143 [A/C] rs4269612 9 113423432 [A/C] rs3001125 9 113431606 [A/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs3010815 9 113434178 [T/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs7040569 9 113454159 [T/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs7049083 9 113463218 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs4498626 9 113463246 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs7018577 9 113463399 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs4978952 9 113466154 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs12347321 9 113466941 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs7856889 9 113467546 [T/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs4623510 9 113468600 [T/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs4401940 9 113468897 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs10980535 9 113472810 [A/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs10980536 9 113475374 [T/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs4297099 9 113476105 [T/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs4415391 9 113480169 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs4336672 9 113485961 [A/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs4259484 9 113486002 [T/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs10759464 9 113493735 [T/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs4574919 9 113501372 [T/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs10980549 9 113503673 [A/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs4532674 9 113503776 [T/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs10980551 9 113504910 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs4144418 9 113506998 [T/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs2846448 9 113509778 [T/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs2298492 9 113512773 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs1940245 9 113522917 [A/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs1940247 9 113523032 [T/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs12001728 9 113523448 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs1940251 9 113526327 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs10817091 9 113527226 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs2766998 9 113531585 [T/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs2148584 9 113536274 [T/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs2274419 9 113538122 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK EXON Missense_M413I,Missense_M335I,Missense_M325I rs16915380 9 113538291 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs2766984 9 113541125 [T/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs1170327 9 113547476 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs525344 9 113552952 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs10759469 9 113560071 [A/C] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs2821143 9 113560119 [A/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs3780529 9 113561251 [T/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK Silent,Silent,Silent rs578430 9 113563143 [T/G] NM_005592,NM_001166280,NM_001166281 MUSK,MUSK,MUSK EXON Missense_V829L,Missense_V743L,Missense_V733L rs521803 9 113565027 [T/G] rs2821142 9 113566357 [T/C] rs1409686 9 113569096 [A/C] rs2846444 9 113570107 [A/G] rs2846451 9 113573073 [A/G] rs16915435 9 113579789 [A/G] rs509276 9 113581359 [A/G] rs2821140 9 113582050 [T/C] rs540171 9 113582391 [A/C] rs12553421 9 113582672 [A/C] rs2767001 9 113584012 [A/G] rs10980575 9 113585503 [A/G] rs10980578 9 113588332 [T/C] rs2821134 9 113590448 [A/G] rs16915444 9 113591023 [T/C] rs544828 9 113591837 [A/G] rs12684949 9 113596088 [T/C] rs2821153 9 113597109 [T/C] rs2846460 9 113597449 [A/C] rs4978958 9 113597800 [T/G] rs4978959 9 113597938 [T/C] rs943327 9 113599422 [T/C] rs3860159 9 113602694 [T/C] rs10980588 9 113609826 [A/G] rs10980596 9 113619757 [A/C] rs474186 9 113622466 [A/G] rs576515 9 113625888 [A/C] rs472936 9 113629491 [A/G] rs512756 9 113631282 [A/G] rs516187 9 113631618 [A/C] rs693342 9 113632279 [A/C] rs12000617 9 113633737 [A/C] rs2766981 9 113635180 [T/C] rs505414 9 113635381 [T/C] rs6833 9 113635691 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1043128 9 113635929 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13094 9 113636353 [T/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs955888 9 113637662 [A/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3739709 9 113637854 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 EXON Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R,Synonymous_R314R rs544276 9 113640468 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs576559 9 113642646 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7029898 9 113646892 [A/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1536435 9 113648839 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7039165 9 113649462 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7854710 9 113654585 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10817107 9 113656170 [A/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1326893 9 113656440 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10817108 9 113658671 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10119345 9 113660985 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1409684 9 113665254 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780528 9 113667277 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1326899 9 113674967 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1326898 9 113675287 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2182577 9 113680831 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10980633 9 113681255 [A/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2766993 9 113683472 [T/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1547664 9 113684143 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1326890 9 113686353 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2254841 9 113690028 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4978968 9 113694355 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10817114 9 113694568 [A/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2900519 9 113696095 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2900520 9 113697520 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4246884 9 113697555 [T/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10980642 9 113697686 [T/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4978970 9 113698031 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10817115 9 113701264 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12555560 9 113703439 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7866715 9 113707225 [T/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10980653 9 113709586 [A/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10817118 9 113712132 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12345986 9 113722721 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10817124 9 113724346 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10980665 9 113732126 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2418124 9 113732167 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2277179 9 113734610 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4978432 9 113735263 [A/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10759478 9 113737589 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16915618 9 113737831 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17382569 9 113747491 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12552125 9 113747902 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12551377 9 113751324 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10980683 9 113753524 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7023788 9 113766668 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1030006 9 113779011 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12353038 9 113782852 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs723591 9 113783435 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10980694 9 113784557 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7039431 9 113785983 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2287005 9 113791313 [T/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3739707 9 113792706 [A/C] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1000115 9 113794500 [A/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7041855 9 113798729 [T/G] NM_001351416,NM_001351417,NM_001351415,NM_001351407,NM_001351414,NM_001351405,NM_001351419,NM_001351406,NM_001351409,NM_001351408,NM_001351420,NM_001351400,NM_001351401,NM_001351399,NM_001351404,NM_001401,NM_001351402,NM_001351403,NM_001351418,NM_001351398,NM_001351413,NM_001351412,NM_001351411,NM_001351410,NM_057159,NM_001351397 LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1,LPAR1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10980705 9 113803185 [T/C] rs4978434 9 113811445 [T/C] rs4576485 9 113815164 [A/G] rs7035625 9 113815456 [T/G] rs1008157 9 113828759 [A/C] rs4978979 9 113831319 [T/C] rs4246886 9 113831644 [T/C] rs10980720 9 113831845 [A/C] rs1978304 9 113834438 [A/C] rs10980729 9 113837805 [A/G] rs10759484 9 113837908 [A/G] rs10817138 9 113838083 [A/G] rs7873139 9 113838967 [T/C] rs2900522 9 113844435 [T/C] rs759279 9 113844806 [T/C] rs7851332 9 113846467 [A/C] rs7863097 9 113848849 [A/C] rs7857633 9 113850877 [T/G] rs10980755 9 113852849 [A/G] rs10980757 9 113853766 [T/C] rs7861175 9 113857337 [T/C] rs10491532 9 113857380 [T/G] rs1002607 9 113858933 [T/C] rs7852442 9 113864119 [A/C] rs9299191 9 113864545 [T/C] rs1476946 9 113864749 [T/C] rs11793292 9 113870526 [T/C] rs7027665 9 113875014 [T/C] rs872069 9 113880073 [T/G] rs872068 9 113880116 [T/C] rs10980780 9 113885415 [T/C] rs1888191 9 113890977 [A/G] rs1411424 9 113892963 [A/G] rs11789772 9 113893460 [T/C] rs10491882 9 113894066 [T/C] rs2418135 9 113901309 [A/G] rs12346499 9 113902881 [T/C] rs2026801 9 113905451 [A/G] rs7870066 9 113911613 [T/C] rs10980800 9 113915905 [T/C] rs10217157 9 113919523 [T/C] rs16915769 9 113923169 [T/C] rs7848895 9 113928554 [T/C] rs17206709 9 113932556 [A/G] rs10980811 9 113933206 [A/G] rs16936387 9 113940924 [A/G] rs7871113 9 113944432 [T/C] rs7020211 9 113949141 [T/C] rs12335533 9 113954413 [A/G] rs7046956 9 113957534 [T/C] rs2039183 9 113958351 [A/C] rs824002 9 113973091 [T/G] rs823999 9 113973553 [A/G] rs10980825 9 113973650 [A/G] rs700131 9 113976743 [T/C] rs1433586 9 113979182 [A/G] rs2570380 9 113983555 [A/G] rs1330272 9 113984805 [A/G] rs7861100 9 113989160 [T/C] rs1836108 9 113990853 [T/G] rs2570387 9 113991207 [T/C] rs2570388 9 113992598 [A/G] rs10980833 9 113993269 [A/G] rs2480804 9 113993589 [A/G] rs7036572 9 113995017 [T/C] rs700137 9 113997789 [A/G] rs824012 9 114002747 [T/C] rs17813724 9 114003466 [T/C] rs7025866 9 114004604 [A/G] rs11788536 9 114008711 [A/C] rs700144 9 114021014 [A/G] rs12002838 9 114023316 [T/G] rs12346444 9 114027937 [T/C] rs10980841 9 114030915 [T/G] rs534643 9 114038704 [T/C] rs691720 9 114040326 [A/G] rs690722 9 114044933 [A/G] rs10980847 9 114046614 [A/G] rs9299194 9 114046908 [A/G] rs10980854 9 114050357 [A/G] rs10980855 9 114050929 [A/G] rs16915951 9 114051208 [T/G] rs700148 9 114052520 [T/C] rs695207 9 114056169 [T/G] rs10980857 9 114059341 [A/G] rs4978988 9 114063446 [T/C] rs4978437 9 114069273 [A/G] rs2095108 9 114078716 [T/C] rs12347972 9 114087402 [A/G] rs866624 9 114087696 [A/G] rs10119296 9 114088807 [A/G] rs10116988 9 114111170 [A/G] rs2418157 9 114119984 [A/C] rs2151182 9 114122017 [T/C] rs16915992 9 114122763 [A/G] rs7038983 9 114125818 [A/G] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS Silent,Silent,Silent,Silent,Silent rs2297524 9 114125835 [A/G] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS Silent,Silent,Silent,Silent,Silent rs4978992 9 114129847 [T/C] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS Silent,Silent,Silent,Silent,Silent rs10980884 9 114134198 [A/C] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS Silent,Silent,Silent,Silent,Silent rs2274898 9 114138702 [A/G] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS Silent,Silent,Silent,Silent,Silent rs16916040 9 114146832 [T/C] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS EXON Synonymous_A1223A,Synonymous_A1217A,Synonymous_A1217A,Synonymous_A1217A,Synonymous_A1395A rs2418159 9 114161657 [T/C] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS Silent,Silent,Silent,Silent,Silent rs3818719 9 114173689 [A/G] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS Silent,Silent,Silent,Silent,Silent rs16916080 9 114182353 [T/C] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS EXON Synonymous_V507V,Synonymous_V501V,Synonymous_V501V,Synonymous_V501V,Synonymous_V679V rs7038720 9 114184108 [T/C] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS Silent,Silent,Silent,Silent,Silent rs868405 9 114184477 [T/C] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS EXON Synonymous_R429R,Synonymous_R423R,Synonymous_R423R,Synonymous_R423R,Synonymous_R601R rs1041576 9 114185794 [T/G] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS Silent,Silent,Silent,Silent,Silent rs16916100 9 114190337 [A/G] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS EXON Synonymous_F351F,Synonymous_F345F,Synonymous_F345F,Synonymous_F345F,Synonymous_F523F rs12345793 9 114191098 [A/G] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS Silent,Silent,Silent,Silent,Silent rs7018469 9 114195274 [T/C] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS Silent,Silent,Silent,Silent,Silent rs2297530 9 114195587 [A/G] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS EXON Synonymous_H264H,Synonymous_H258H,Synonymous_H258H,Synonymous_H258H,Synonymous_H436H rs10759497 9 114220603 [T/C] NM_001364931,NM_001364930,NM_001364929,NM_001363756,NM_001080398 ECPAS,ECPAS,ECPAS,ECPAS,ECPAS Silent,Silent,Silent,Silent,Silent rs7868884 9 114251696 [A/G] rs12003641 9 114279497 [T/C] rs12351218 9 114283327 [A/G] rs12346895 9 114286772 [A/C] rs9299199 9 114287275 [T/C] rs7851745 9 114287818 [T/G] NM_001007169,NM_133464 ZNF483,ZNF483 Silent,Silent rs10441737 9 114301585 [T/C] NM_001007169,NM_133464 ZNF483,ZNF483 Silent,Silent rs10759501 9 114305576 [T/C] NM_001007169,NM_133464 ZNF483,ZNF483 EXON Silent,Silent rs12341420 9 114316077 [T/C] NM_001007169,NM_133464,NM_001146109 ZNF483,ZNF483,PTGR1 EXON Silent,Silent,Silent rs7027778 9 114318911 [A/G] NM_001007169,NM_001146109 ZNF483,PTGR1 Silent,Silent rs7020283 9 114332765 [T/C] NM_001007169,NM_001146109,NM_001146108,NM_012212 ZNF483,PTGR1,PTGR1,PTGR1 Silent,Silent,Silent,Silent rs10122842 9 114335885 [A/G] NM_001007169,NM_001146109,NM_001146108,NM_012212 ZNF483,PTGR1,PTGR1,PTGR1 Silent,Silent,Silent,Silent rs17320021 9 114341033 [T/C] NM_001146109,NM_001146108,NM_012212 PTGR1,PTGR1,PTGR1 Silent,Silent,Silent rs17320055 9 114341376 [T/C] NM_001146109,NM_001146108,NM_012212 PTGR1,PTGR1,PTGR1 Silent,Silent,Silent rs10491726 9 114342146 [A/G] NM_001146109,NM_001146108,NM_012212 PTGR1,PTGR1,PTGR1 Silent,Silent,Silent rs10817189 9 114342378 [A/G] NM_001146109,NM_001146108,NM_012212 PTGR1,PTGR1,PTGR1 Silent,Silent,Silent rs12555931 9 114343376 [T/G] NM_001146109,NM_001146108,NM_012212 PTGR1,PTGR1,PTGR1 Silent,Silent,Silent rs10980952 9 114346041 [T/C] NM_001146109,NM_001146108,NM_012212 PTGR1,PTGR1,PTGR1 Silent,Silent,Silent rs10120479 9 114347401 [T/C] NM_001146109,NM_001146108,NM_012212 PTGR1,PTGR1,PTGR1 Silent,Silent,Silent rs2273786 9 114348513 [A/G] NM_001146109,NM_001146108,NM_012212 PTGR1,PTGR1,PTGR1 Silent,Silent,Silent rs2273788 9 114348617 [T/C] NM_001146109,NM_001146108,NM_012212 PTGR1,PTGR1,PTGR1 Silent,Silent,Silent rs6477828 9 114352627 [A/G] NM_001146109,NM_001146108,NM_012212 PTGR1,PTGR1,PTGR1 Silent,Silent,Silent rs3739704 9 114356367 [T/C] NM_001146109,NM_001146108,NM_012212 PTGR1,PTGR1,PTGR1 Silent,Silent,Silent rs10122597 9 114363693 [T/C] rs1475106 9 114365046 [A/G] rs966628 9 114366248 [A/G] NR_034087 LRRC37A5P Silent rs12342716 9 114371624 [A/C] NR_034087 LRRC37A5P Silent rs16916245 9 114374729 [A/G] NR_034087 LRRC37A5P Silent rs10817197 9 114382444 [A/G] rs7036413 9 114384386 [T/C] rs10759503 9 114385055 [A/G] rs10121085 9 114386599 [T/C] rs2065099 9 114393235 [T/C] rs1570303 9 114400998 [A/G] NM_004125,NM_001015882,NR_037148 DNAJC25-GNG10,DNAJC25,DNAJC25 Silent,Silent,Silent rs2146079 9 114406649 [A/G] NM_004125,NM_001015882,NR_037148 DNAJC25-GNG10,DNAJC25,DNAJC25 Silent,Silent,Silent rs4978455 9 114409550 [A/G] NM_004125,NM_001015882,NR_037148 DNAJC25-GNG10,DNAJC25,DNAJC25 Silent,Silent,Silent rs1322259 9 114411891 [T/C] NM_004125,NM_001015882,NR_037148 DNAJC25-GNG10,DNAJC25,DNAJC25 EXON Silent,Synonymous_D216D,Silent rs1051423 9 114416298 [T/G] NM_004125,NM_001015882,NR_037148 DNAJC25-GNG10,DNAJC25,DNAJC25 EXON Silent,Silent,Silent rs12553893 9 114416802 [A/G] NM_004125 DNAJC25-GNG10 Silent rs16916271 9 114417082 [A/G] NM_004125 DNAJC25-GNG10 Silent rs4979028 9 114421608 [T/C] NM_004125 DNAJC25-GNG10 Silent rs4979030 9 114421679 [A/G] NM_004125 DNAJC25-GNG10 Silent rs4979031 9 114423433 [A/G] NM_004125 DNAJC25-GNG10 Silent rs12376497 9 114426645 [T/G] NM_004125,NM_001198664,NM_001017998 DNAJC25-GNG10,GNG10,GNG10 Silent,Silent,Silent rs4979034 9 114435668 [A/G] rs7863832 9 114444565 [A/G] rs16916293 9 114447531 [A/G] rs6477842 9 114449970 [T/C] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 Silent,Silent,Silent rs10981012 9 114453006 [A/G] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 Silent,Silent,Silent rs1475110 9 114454580 [A/G] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 EXON Silent,Missense_I1162T,Missense_I1123T rs12343237 9 114454732 [T/C] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 EXON Silent,Synonymous_P1111P,Synonymous_P1072P rs7029713 9 114454886 [A/G] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 Silent,Silent,Silent rs10981014 9 114458600 [T/C] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 Silent,Silent,Silent rs10981018 9 114461077 [T/C] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 Silent,Silent,Silent rs6477845 9 114462322 [A/G] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 EXON Silent,Missense_L968P,Missense_L929P rs1407390 9 114464487 [T/C] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 EXON Silent,Missense_Y932C,Missense_Y893C rs10981022 9 114464733 [T/C] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 Silent,Silent,Silent rs7036568 9 114468966 [A/C] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 EXON Silent,Missense_N809K,Missense_N770K rs12683681 9 114470127 [A/G] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 Silent,Silent,Silent rs7868266 9 114470138 [T/C] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 EXON Silent,Missense_R788K,Missense_R749K rs9657640 9 114481631 [A/G] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 Silent,Silent,Silent rs12683870 9 114482980 [T/C] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 Silent,Silent,Silent rs1337581 9 114484682 [T/C] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 Silent,Silent,Silent rs12352352 9 114484783 [A/G] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 EXON Silent,Synonymous_P615P,Synonymous_P576P rs953536 9 114489887 [T/C] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 Silent,Silent,Silent rs7470491 9 114490308 [T/C] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 EXON Silent,Missense_H416R,Missense_H377R rs10119000 9 114490365 [T/C] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 Silent,Silent,Silent rs12339927 9 114507314 [T/C] NR_109816,NM_173521,NM_001080551 C9orf84,C9orf84,C9orf84 Silent,Silent,Silent rs823639 9 114542451 [T/C] NR_109816,NM_173521 C9orf84,C9orf84 Silent,Silent rs823638 9 114542761 [T/C] NR_109816,NM_173521 C9orf84,C9orf84 Silent,Silent rs559248 9 114545878 [T/C] NR_109816 C9orf84 Silent rs12343082 9 114546234 [T/G] NR_109816 C9orf84 Silent rs823645 9 114557475 [A/G] rs10981078 9 114561679 [T/C] rs446465 9 114562289 [T/G] rs10981079 9 114563069 [A/C] rs667463 9 114567760 [T/C] rs7875230 9 114572011 [T/C] rs10981083 9 114572203 [A/C] rs7849275 9 114575749 [A/G] rs7045809 9 114577770 [T/C] rs700049 9 114582649 [T/G] rs10981097 9 114590748 [T/C] rs7036787 9 114591865 [A/G] rs10981100 9 114593311 [A/G] rs7042137 9 114593488 [T/C] rs4978466 9 114599048 [A/G] rs16916411 9 114606411 [T/G] rs4979054 9 114607816 [T/C] rs12376643 9 114612458 [T/G] rs10817227 9 114615980 [A/G] rs10981126 9 114621854 [A/G] rs315712 9 114627170 [A/G] rs12379047 9 114629162 [A/G] rs12002142 9 114633078 [A/G] rs12001972 9 114636015 [T/C] rs10121681 9 114638922 [A/G] rs13295839 9 114639407 [T/G] rs7023375 9 114639652 [T/C] rs7043162 9 114641291 [A/C] rs2418192 9 114643893 [T/C] rs10981136 9 114645077 [T/C] rs9299201 9 114654601 [T/C] rs1413218 9 114658407 [T/C] rs1413219 9 114658469 [A/G] rs7042346 9 114661611 [T/G] NM_003358 UGCG Silent rs12554037 9 114668639 [A/C] NM_003358 UGCG Silent rs10759516 9 114672325 [A/G] NM_003358 UGCG Silent rs16916456 9 114672865 [T/C] NM_003358 UGCG Silent rs1813202 9 114688103 [A/G] NM_003358 UGCG Silent rs3824464 9 114690765 [A/G] NM_003358 UGCG Silent rs7850023 9 114694486 [A/G] NM_003358 UGCG EXON Synonymous_T287T rs7873908 9 114699654 [T/C] rs7860208 9 114699757 [T/C] rs7860334 9 114699872 [T/C] rs10981165 9 114700584 [A/G] rs7041171 9 114701630 [T/C] rs7041597 9 114701909 [T/G] rs7854170 9 114702514 [A/G] rs10125079 9 114703029 [A/G] rs10817241 9 114703106 [T/C] rs10125129 9 114703215 [A/G] rs10981168 9 114703347 [T/C] rs7031902 9 114705137 [T/C] rs7046626 9 114705265 [A/G] rs16916492 9 114706396 [A/C] rs7848697 9 114706412 [A/G] rs10817246 9 114707212 [T/C] rs419097 9 114711743 [T/C] rs170282 9 114714853 [A/G] rs13299128 9 114721455 [A/G] rs2900535 9 114721483 [A/G] rs1889224 9 114721683 [T/G] rs1889223 9 114721737 [A/G] rs4979067 9 114724494 [T/C] rs4978473 9 114727220 [A/C] rs7047037 9 114729853 [T/C] rs10733581 9 114731867 [T/C] rs12005421 9 114732385 [A/G] rs6477867 9 114733502 [T/G] rs2418194 9 114736410 [A/G] rs12000633 9 114747481 [A/G] rs2805481 9 114749320 [T/C] rs12376779 9 114753347 [T/G] rs4979071 9 114758073 [T/C] rs4979072 9 114759313 [T/G] rs12004156 9 114764995 [T/C] rs13299968 9 114765400 [T/C] rs7859911 9 114768887 [A/G] rs4979073 9 114774328 [T/C] rs10981207 9 114775448 [T/C] rs12379084 9 114776541 [A/C] rs10981208 9 114777275 [A/G] rs16916578 9 114777545 [A/G] rs4401941 9 114778046 [T/C] rs10981210 9 114780290 [T/C] rs2281787 9 114791018 [A/G] rs1324210 9 114791150 [A/G] rs10125054 9 114798037 [A/G] rs2281788 9 114803286 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 EXON Synonymous_E910E,Silent,Silent rs2281790 9 114803631 [A/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 EXON Synonymous_G795G,Silent,Silent rs7854368 9 114807641 [A/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs10981228 9 114810102 [A/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs10981230 9 114811564 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs16916617 9 114814643 [A/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs7034341 9 114814828 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs7024469 9 114816145 [T/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs16916623 9 114821568 [A/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs4979077 9 114822868 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs4979078 9 114823121 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs4979079 9 114823298 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs10981242 9 114823991 [A/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs10817260 9 114828332 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs2762495 9 114832050 [A/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs2762496 9 114832919 [A/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs2043057 9 114837321 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs10116017 9 114837337 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs7862743 9 114839679 [T/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs2782942 9 114843415 [T/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs3849119 9 114844254 [A/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs9408834 9 114844883 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs10981252 9 114846751 [A/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs2782931 9 114850190 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs16916655 9 114854298 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs7032451 9 114856721 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs3849120 9 114858776 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs12686374 9 114868037 [A/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs12338324 9 114870301 [A/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs2476934 9 114875617 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs2762472 9 114877392 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs9408838 9 114879755 [A/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs2762475 9 114888516 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs2177667 9 114888773 [A/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs7870176 9 114902932 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs17829458 9 114904705 [C/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 EXON Missense_Q201E,Missense_Q201E,Missense_Q201E rs3780513 9 114904712 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 EXON Synonymous_L198L,Synonymous_L198L,Synonymous_L198L rs700098 9 114907131 [A/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs10981281 9 114910679 [A/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs10817270 9 114912752 [A/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs2900537 9 114917202 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs700105 9 114919707 [A/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs9886804 9 114922067 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs10981291 9 114924720 [T/C] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs10817277 9 114934532 [A/G] NM_022486,NM_001282640,NM_001282643 SUSD1,SUSD1,SUSD1 Silent,Silent,Silent rs10759529 9 114938931 [A/G] rs4979087 9 114942200 [A/C] rs10981305 9 114960138 [T/C] rs12554866 9 114963346 [T/C] rs7874580 9 114973383 [A/C] rs10817291 9 114976485 [A/G] rs6575 9 114980967 [T/C] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 EXON Silent,Silent,Silent,Silent,Silent,Silent rs14255 9 114981378 [T/G] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 EXON Silent,Silent,Silent,Silent,Silent,Silent rs7855745 9 114982463 [T/C] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 EXON Silent,Silent,Silent,Missense_T545A,Silent,Silent rs7869523 9 114982549 [T/C] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 EXON Silent,Silent,Silent,Missense_S516N,Silent,Silent rs1534069 9 114985497 [T/C] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 EXON Silent,Silent,Silent,Silent,Silent,Silent rs7041185 9 114987364 [T/G] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 Silent,Silent,Silent,Silent,Silent,Silent rs6477900 9 114989616 [A/G] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 Silent,Silent,Silent,Silent,Silent,Silent rs7038217 9 115004510 [A/G] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 Silent,Silent,Silent,Silent,Silent,Silent rs1359878 9 115011317 [A/G] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 Silent,Silent,Silent,Silent,Silent,Silent rs10817301 9 115015710 [A/G] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 Silent,Silent,Silent,Silent,Silent,Silent rs7874660 9 115023853 [A/G] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 Silent,Silent,Silent,Silent,Silent,Silent rs7870866 9 115030570 [T/C] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 Silent,Silent,Silent,Silent,Silent,Silent rs10981337 9 115035134 [A/G] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 Silent,Silent,Silent,Silent,Silent,Silent rs10981338 9 115036021 [T/G] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 Silent,Silent,Silent,Silent,Silent,Silent rs7875779 9 115039845 [T/C] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 Silent,Silent,Silent,Silent,Silent,Silent rs10481666 9 115042805 [A/C] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 Silent,Silent,Silent,Silent,Silent,Silent rs4310281 9 115085206 [A/G] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 Silent,Silent,Silent,Silent,Silent,Silent rs4542000 9 115088669 [T/C] NM_001244896,NM_001244898,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 Silent,Silent,Silent,Silent,Silent,Silent rs7040447 9 115095743 [T/C] NM_001244896,NM_001163790,NM_001244897,NM_005156,NM_001163788 PTBP3,PTBP3,PTBP3,PTBP3,PTBP3 Silent,Silent,Silent,Silent,Silent rs10817319 9 115103266 [A/G] rs12685878 9 115120143 [A/G] rs7862690 9 115137476 [T/C] rs4979108 9 115140133 [T/C] rs10817330 9 115140735 [A/G] rs6477923 9 115141720 [A/G] rs10453231 9 115144922 [A/G] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs7857421 9 115151692 [A/G] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs6477925 9 115155264 [T/C] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs7852741 9 115156389 [T/C] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs4978489 9 115167146 [T/C] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs6477929 9 115169183 [A/G] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs1571639 9 115170313 [T/G] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs10733588 9 115171062 [T/C] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs1537055 9 115171986 [T/G] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs10739349 9 115178029 [A/C] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs4979113 9 115182612 [T/C] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs7857000 9 115193763 [T/G] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs7038491 9 115196114 [T/C] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs10817341 9 115196558 [A/G] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs10759563 9 115202068 [A/G] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs10817344 9 115205042 [T/G] NR_036651,NM_001195822,NM_032303 HSDL2,HSDL2,HSDL2 Silent,Silent,Silent rs3739696 9 115216321 [A/G] NR_036651,NM_001195822,NM_032303,NM_001350649 HSDL2,HSDL2,HSDL2,C9orf147 EXON Silent,Synonymous_K225K,Synonymous_K298K,Missense_F139L rs7862037 9 115219619 [T/G] NR_036651,NM_001195822,NM_032303,NM_001350649 HSDL2,HSDL2,HSDL2,C9orf147 Silent,Silent,Silent,Silent rs1411680 9 115229693 [A/G] NR_036651,NM_001195822,NM_032303,NM_001350649 HSDL2,HSDL2,HSDL2,C9orf147 Silent,Silent,Silent,Silent rs7096 9 115234611 [A/G] NR_036651,NM_001195822,NM_032303,NM_001350649 HSDL2,HSDL2,HSDL2,C9orf147 EXON Silent,Silent,Silent,Silent rs7871916 9 115248932 [A/G] NM_001350649 C9orf147 Silent rs4979125 9 115265330 [T/C] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs7018648 9 115270889 [T/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs16917040 9 115282036 [T/C] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs4979128 9 115289605 [T/C] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs10121738 9 115292080 [T/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs10759577 9 115302544 [A/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs16917084 9 115315180 [T/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs10817357 9 115316399 [A/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs10981445 9 115326187 [T/C] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs2806320 9 115335386 [A/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs7040835 9 115343222 [A/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs2593684 9 115347088 [A/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs10739367 9 115367078 [T/C] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs2676629 9 115371397 [A/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs1517079 9 115373695 [A/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs16917155 9 115390448 [T/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs2798317 9 115399064 [T/C] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs11788361 9 115401368 [A/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs16917164 9 115402006 [A/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs2995806 9 115403585 [T/C] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs10739369 9 115404746 [T/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs12004834 9 115406590 [T/C] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs786990 9 115416257 [A/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs1568125 9 115416612 [A/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs4979141 9 115417171 [A/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs4979142 9 115421424 [A/G] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 Silent,Silent,Silent rs16917185 9 115421788 [A/C] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 EXON Synonymous_I530I,Silent,Synonymous_I558I rs7028901 9 115422854 [T/C] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 EXON Silent,Silent,Silent rs2040062 9 115426603 [T/C] NM_133465,NM_001287038,NM_001287036 KIAA1958,KIAA1958,KIAA1958 EXON Silent,Silent,Silent rs12002812 9 115429998 [A/G] rs11998945 9 115430157 [T/C] rs7040287 9 115430670 [A/G] rs10759581 9 115440165 [A/G] rs10981474 9 115442494 [T/C] rs786962 9 115444828 [A/G] rs2173196 9 115446426 [T/C] NM_001329586,NM_001329588,NR_138056,NR_138055,NM_021218,NM_001329587,NR_138054,NM_001329585,NM_001329589,NM_001329590 INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs786963 9 115447935 [T/C] NM_001329586,NM_001329588,NR_138056,NR_138055,NM_021218,NM_001329587,NR_138054,NM_001329585,NM_001329589,NM_001329590 INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs786966 9 115448341 [T/G] NM_001329586,NM_001329588,NR_138056,NR_138055,NM_021218,NM_001329587,NR_138054,NM_001329585,NM_001329589,NM_001329590 INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs786968 9 115449110 [T/C] NM_001329586,NM_001329588,NR_138056,NR_138055,NM_021218,NM_001329587,NR_138054,NM_001329585,NM_001329589,NM_001329590 INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2676622 9 115454504 [A/C] NM_001329586,NM_001329588,NR_138056,NR_138055,NM_021218,NM_001329587,NR_138054,NM_001329585,NM_001329589,NM_001329590 INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs786978 9 115460239 [A/G] NM_001329586,NM_001329588,NR_138056,NR_138055,NM_021218,NM_001329587,NR_138054,NM_001329585,NM_001329589,NM_001329590 INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2798316 9 115462552 [T/C] NM_001329586,NM_001329588,NR_138056,NR_138055,NM_021218,NM_001329587,NR_138054,NM_001329585,NM_001329589,NM_001329590 INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs805050 9 115472230 [A/G] NM_001329586,NM_001329588,NR_138056,NR_138055,NM_021218,NM_001329587,NR_138054,NM_001329585,NM_001329589,NM_001329590 INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10513168 9 115476640 [T/C] NM_001329586,NM_001329588,NR_138056,NR_138055,NM_021218,NM_001329587,NR_138054,NM_001329585,NM_001329589,NM_001329590 INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP,INIP Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2173193 9 115509156 [T/C] rs2645986 9 115517264 [T/C] NM_001012994 SNX30 Silent rs2796033 9 115519675 [T/C] NM_001012994 SNX30 Silent rs2796032 9 115519904 [T/C] NM_001012994 SNX30 Silent rs10981499 9 115525259 [T/C] NM_001012994 SNX30 Silent rs1891403 9 115527183 [T/C] NM_001012994 SNX30 Silent rs7039744 9 115531238 [T/C] NM_001012994 SNX30 Silent rs7044734 9 115546442 [T/G] NM_001012994 SNX30 Silent rs787271 9 115549463 [T/C] NM_001012994 SNX30 Silent rs787274 9 115550363 [A/C] NM_001012994 SNX30 Silent rs10739371 9 115558246 [A/G] NM_001012994 SNX30 Silent rs2153839 9 115559659 [A/G] NM_001012994 SNX30 Silent rs10817388 9 115566800 [T/G] NM_001012994 SNX30 Silent rs12555600 9 115585109 [T/G] NM_001012994 SNX30 Silent rs10120988 9 115589251 [T/C] NM_001012994 SNX30 Silent rs1539339 9 115593729 [A/C] NM_001012994 SNX30 Silent rs10817396 9 115609941 [T/C] NM_001012994 SNX30 Silent rs1539341 9 115616110 [A/G] NM_001012994 SNX30 Silent rs10481671 9 115617291 [A/G] NM_001012994 SNX30 Silent rs10115576 9 115617822 [T/C] NM_001012994 SNX30 Silent rs11794827 9 115620375 [T/C] NM_001012994 SNX30 Silent rs2182046 9 115625699 [T/C] NM_001012994 SNX30 Silent rs4978508 9 115627012 [A/G] NM_001012994 SNX30 Silent rs16917417 9 115632898 [A/G] NM_001012994 SNX30 EXON Silent rs2025544 9 115632969 [A/G] NM_001012994 SNX30 EXON Silent rs10116897 9 115633479 [T/C] NM_001012994 SNX30 EXON Silent rs1324931 9 115634282 [T/C] NM_001012994 SNX30 EXON Silent rs12684608 9 115637018 [A/G] NM_001012994 SNX30 EXON Silent rs10759604 9 115639748 [A/G] rs16917440 9 115641569 [A/C] NM_033051 SLC46A2 EXON Silent rs10156558 9 115645184 [T/C] NM_033051 SLC46A2 Silent rs13283782 9 115653026 [T/C] NM_033051 SLC46A2 EXON Silent rs4142852 9 115654098 [T/C] rs4978511 9 115654246 [T/C] rs10124939 9 115654683 [T/C] rs4978512 9 115660368 [A/G] rs11788257 9 115662517 [T/C] rs10981540 9 115666561 [T/G] rs17751300 9 115669613 [T/C] rs912664 9 115669711 [A/G] rs912670 9 115673030 [T/C] rs1952004 9 115674281 [A/G] rs12377544 9 115675673 [T/G] rs16917488 9 115677392 [T/C] rs11791620 9 115677671 [T/G] rs1925081 9 115678033 [T/C] rs10817404 9 115678692 [T/C] rs16917501 9 115681924 [A/C] rs11790986 9 115682269 [T/C] rs10759611 9 115683429 [T/C] rs10817407 9 115684234 [T/C] rs10759614 9 115687192 [A/G] rs10817408 9 115687735 [T/C] rs4571802 9 115688494 [T/C] rs1324952 9 115694415 [A/G] rs10981550 9 115694490 [T/C] rs6477967 9 115694935 [T/G] rs10817411 9 115696187 [T/C] rs4978519 9 115697999 [A/G] rs747065 9 115698104 [T/C] rs747066 9 115698346 [T/C] rs11792260 9 115702065 [A/G] rs1886524 9 115702253 [A/G] rs2025540 9 115703307 [A/G] rs10817414 9 115707599 [A/G] rs7043761 9 115707661 [T/C] rs6477968 9 115708164 [A/C] rs10733601 9 115709698 [A/G] rs4532675 9 115710102 [A/G] rs7858808 9 115712068 [A/G] rs7874374 9 115712252 [T/C] rs7020864 9 115714804 [A/G] rs995366 9 115716155 [T/C] rs16917605 9 115716215 [T/G] rs12115363 9 115716647 [A/G] rs979596 9 115720888 [T/C] rs10817416 9 115722489 [T/C] rs1408696 9 115723429 [A/G] rs10981559 9 115724471 [A/C] rs3903908 9 115724490 [T/C] rs3903907 9 115724549 [A/G] rs9886741 9 115733682 [A/G] rs7040359 9 115737459 [A/C] rs4618774 9 115740086 [T/G] rs1408691 9 115745205 [T/C] rs2104391 9 115745240 [T/C] rs10981576 9 115745656 [A/G] rs3945761 9 115747393 [T/C] rs4979204 9 115757581 [T/C] rs3739840 9 115759468 [A/T] NM_001101338 ZNF883 EXON Missense_F358I rs10981589 9 115759519 [A/G] NM_001101338 ZNF883 EXON Nonsense_R341X rs10513176 9 115761221 [T/G] NM_001101338 ZNF883 EXON Silent rs1324935 9 115764076 [A/G] NM_001101338 ZNF883 Silent rs10981592 9 115764347 [A/C] NM_001101338 ZNF883 EXON Silent rs6477978 9 115770285 [A/C] NM_001101338 ZNF883 Silent rs1570756 9 115775168 [T/C] rs4246894 9 115777556 [T/C] rs2418246 9 115781111 [T/C] rs4979208 9 115783589 [T/C] rs1411600 9 115788707 [A/G] rs9299213 9 115789373 [T/C] rs16917698 9 115790227 [A/G] rs7863800 9 115794341 [A/G] rs10739386 9 115794588 [T/C] rs10817431 9 115794614 [A/G] rs16917707 9 115794712 [A/G] rs10981613 9 115796553 [T/G] rs10981618 9 115802287 [A/C] rs1411606 9 115807193 [T/C] NM_001282518,NM_001282515,NM_003408 ZFP37,ZFP37,ZFP37 Silent,Silent,Silent rs1411605 9 115808300 [A/G] NM_001282518,NM_001282515,NM_003408 ZFP37,ZFP37,ZFP37 Silent,Silent,Silent rs12003447 9 115811102 [T/C] NM_001282518,NM_001282515,NM_003408 ZFP37,ZFP37,ZFP37 Silent,Silent,Silent rs10981621 9 115815398 [A/G] NM_001282518,NM_001282515,NM_003408 ZFP37,ZFP37,ZFP37 Silent,Silent,Silent rs10981622 9 115817156 [A/G] NM_001282518,NM_001282515,NM_003408 ZFP37,ZFP37,ZFP37 Silent,Silent,Silent rs11791740 9 115819250 [T/C] rs10759623 9 115821485 [T/C] rs7022165 9 115852715 [T/C] rs1411604 9 115861201 [T/G] rs1008016 9 115862852 [A/G] rs16928463 9 115863910 [T/C] rs7034705 9 115864465 [A/G] rs13294922 9 115864525 [A/C] rs17828145 9 115865501 [A/G] rs6477983 9 115866017 [T/G] rs10981630 9 115866273 [T/C] rs2009977 9 115867276 [A/G] NR_024376 FAM225B EXON Silent rs2039221 9 115874261 [T/C] rs12236936 9 115881664 [T/G] NR_024366 FAM225A EXON Silent rs10817441 9 115885060 [A/G] rs4598325 9 115893229 [A/G] rs10981639 9 115897653 [T/C] rs10981640 9 115897803 [A/C] rs10513183 9 115899317 [T/C] rs9792498 9 115900533 [T/C] rs12336914 9 115901241 [A/G] rs4979216 9 115905480 [A/G] rs10981645 9 115905837 [A/G] rs12115536 9 115905850 [A/G] rs10981648 9 115908452 [T/C] rs10981650 9 115910991 [T/G] rs10817446 9 115911904 [A/C] rs35121715 9 115912772 [T/C] rs11794048 9 115915194 [A/G] NM_001860 SLC31A2 Silent rs7027743 9 115915624 [A/G] NM_001860 SLC31A2 Silent rs4263842 9 115917783 [T/C] NM_001860 SLC31A2 Silent rs10121164 9 115918552 [A/G] NM_001860 SLC31A2 Silent rs3934969 9 115919782 [T/C] NM_001860 SLC31A2 Silent rs4344146 9 115920099 [T/C] NM_001860 SLC31A2 Silent rs4483236 9 115921843 [A/C] NM_001860 SLC31A2 Silent rs7849150 9 115922694 [T/C] NM_001860 SLC31A2 Silent rs4073133 9 115924388 [T/C] NM_001860 SLC31A2 Silent rs3827672 9 115924811 [T/C] NM_001860 SLC31A2 Silent rs3810906 9 115925104 [T/C] NM_001860 SLC31A2 EXON Synonymous_A113A rs1128774 9 115925396 [A/G] NM_001860 SLC31A2 EXON Silent rs2571 9 115926317 [T/G] NM_001860 SLC31A2 EXON Silent rs1128150 9 115927857 [A/G] NM_015258 FKBP15 EXON Silent rs3810908 9 115928275 [T/C] NM_015258 FKBP15 EXON Silent rs10739387 9 115934852 [A/C] NM_015258 FKBP15 Silent rs10981669 9 115938318 [T/C] NM_015258 FKBP15 Silent rs17762224 9 115938750 [T/C] NM_015258 FKBP15 Silent rs10118914 9 115941144 [T/C] NM_015258 FKBP15 Silent rs10981674 9 115946170 [A/G] NM_015258 FKBP15 Silent rs10465129 9 115950156 [A/G] NM_015258 FKBP15 EXON Missense_L434F rs12684417 9 115952895 [T/C] NM_015258 FKBP15 Silent rs16926788 9 115957093 [T/C] NM_015258 FKBP15 Silent rs10981683 9 115960547 [A/G] NM_015258 FKBP15 Silent rs7852613 9 115962551 [A/C] NM_015258 FKBP15 Silent rs7029139 9 115963507 [T/C] NM_015258 FKBP15 Silent rs12380325 9 115964664 [T/C] NM_015258 FKBP15 Silent rs1133618 9 115968797 [T/C] NM_015258 FKBP15 EXON Missense_A106T rs6477997 9 115981113 [T/C] NM_015258 FKBP15 Silent rs2233913 9 115983216 [T/C] NM_015258 FKBP15 Silent rs2233914 9 115983540 [A/G] NM_015258 FKBP15 EXON Silent rs10513189 9 115990221 [T/C] NM_001859 SLC31A1 Silent rs10981696 9 115991417 [T/C] NM_001859 SLC31A1 Silent rs10981699 9 115995901 [T/C] NM_001859 SLC31A1 Silent rs6477998 9 115997249 [A/C] NM_001859 SLC31A1 Silent rs7851623 9 116002565 [T/C] NM_001859 SLC31A1 Silent rs10817465 9 116005783 [T/C] NM_001859 SLC31A1 Silent rs16930959 9 116011458 [A/G] NM_001859 SLC31A1 Silent rs2233916 9 116021136 [C/G] NM_001859 SLC31A1 EXON Missense_T122S rs10759637 9 116025024 [A/C] NM_001859 SLC31A1 EXON Silent rs3087548 9 116029174 [T/C] rs3810919 9 116037894 [T/C] rs12342549 9 116041061 [T/G] NM_004697,NR_136266,NM_001322267,NM_001322266,NM_001244926,NR_136265 PRPF4,PRPF4,PRPF4,PRPF4,PRPF4,PRPF4 Silent,Silent,Silent,Silent,Silent,Silent rs10733604 9 116042263 [A/C] NM_004697,NR_136266,NM_001322267,NM_001322266,NM_001244926,NR_136265 PRPF4,PRPF4,PRPF4,PRPF4,PRPF4,PRPF4 Silent,Silent,Silent,Silent,Silent,Silent rs10759638 9 116042492 [T/G] NM_004697,NR_136266,NM_001322267,NM_001322266,NM_001244926,NR_136265 PRPF4,PRPF4,PRPF4,PRPF4,PRPF4,PRPF4 Silent,Silent,Silent,Silent,Silent,Silent rs12352784 9 116045074 [A/G] NM_004697,NR_136266,NM_001322267,NM_001322266,NM_001244926,NR_136265 PRPF4,PRPF4,PRPF4,PRPF4,PRPF4,PRPF4 Silent,Silent,Silent,Silent,Silent,Silent rs16932083 9 116045272 [A/G] NM_004697,NR_136266,NM_001322267,NM_001322266,NM_001244926,NR_136265 PRPF4,PRPF4,PRPF4,PRPF4,PRPF4,PRPF4 Silent,Silent,Silent,Silent,Silent,Silent rs4979232 9 116048874 [A/G] NM_004697,NR_136266,NM_001322267,NM_001322266,NM_001244926,NR_136265 PRPF4,PRPF4,PRPF4,PRPF4,PRPF4,PRPF4 Silent,Silent,Silent,Silent,Silent,Silent rs10981714 9 116048977 [T/C] NM_004697,NR_136266,NM_001322267,NM_001322266,NM_001244926,NR_136265 PRPF4,PRPF4,PRPF4,PRPF4,PRPF4,PRPF4 Silent,Silent,Silent,Silent,Silent,Silent rs2418249 9 116054040 [T/C] NM_004697,NR_136266,NM_001322267,NM_001322266,NM_001244926,NR_136265 PRPF4,PRPF4,PRPF4,PRPF4,PRPF4,PRPF4 EXON Silent,Silent,Silent,Silent,Silent,Silent rs10817475 9 116059054 [A/G] rs16932319 9 116059530 [T/G] NM_145051 RNF183 EXON Silent rs3750534 9 116060124 [T/C] NM_145051 RNF183 EXON Missense_Q114R rs3750533 9 116060221 [T/C] NM_145051 RNF183 EXON Missense_A82T rs3750532 9 116060487 [T/C] NM_145051 RNF183 EXON Silent rs7860625 9 116065087 [A/G] rs10817476 9 116066958 [T/C] rs10124515 9 116073892 [T/C] rs12684385 9 116077694 [T/G] NM_145241,NR_134677,NM_001006615,NM_001012361 WDR31,WDR31,WDR31,WDR31 EXON Silent,Silent,Silent,Silent rs17764563 9 116078468 [A/C] NM_145241,NR_134677,NM_001006615,NM_001012361 WDR31,WDR31,WDR31,WDR31 EXON Silent,Silent,Silent,Silent rs7038589 9 116081449 [A/G] NM_145241,NR_134677,NM_001006615,NM_001012361 WDR31,WDR31,WDR31,WDR31 Silent,Silent,Silent,Silent rs16932649 9 116084691 [A/G] NM_145241,NR_134677,NM_001006615,NM_001012361 WDR31,WDR31,WDR31,WDR31 Silent,Silent,Silent,Silent rs10817479 9 116085423 [A/G] NM_145241,NR_134677,NM_001006615,NM_001012361 WDR31,WDR31,WDR31,WDR31 EXON Missense_P112S,Silent,Silent,Missense_P113S rs3810921 9 116091342 [T/C] NM_145241,NR_134677,NM_001006615,NM_001012361 WDR31,WDR31,WDR31,WDR31 Silent,Silent,Silent,Silent rs4636275 9 116097493 [T/C] NM_145241,NR_134677,NM_001006615,NM_001012361 WDR31,WDR31,WDR31,WDR31 Silent,Silent,Silent,Silent rs12350377 9 116097835 [T/C] NM_145241,NR_134677,NM_001006615,NM_001012361 WDR31,WDR31,WDR31,WDR31 Silent,Silent,Silent,Silent rs10481674 9 116102463 [T/C] NM_145241,NR_134677,NM_001006615,NM_001012361 WDR31,WDR31,WDR31,WDR31 Silent,Silent,Silent,Silent rs1998503 9 116111407 [A/G] rs4979237 9 116118952 [T/C] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY Silent,Silent,Silent rs4978539 9 116121520 [T/C] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY Silent,Silent,Silent rs1077636 9 116122326 [T/C] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY Silent,Silent,Silent rs752757 9 116122954 [A/G] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY EXON Synonymous_K156K,Synonymous_K156K,Synonymous_K156K rs7038037 9 116124325 [A/G] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY Silent,Silent,Silent rs10981769 9 116125789 [T/C] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY Silent,Silent,Silent rs12342334 9 116128568 [A/C] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY Silent,Silent,Silent rs4979243 9 116128884 [T/G] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY Silent,Silent,Silent rs7857932 9 116130924 [T/C] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY Silent,Silent,Silent rs818710 9 116131453 [A/C] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY Silent,Silent,Silent rs3789254 9 116131580 [T/C] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY Silent,Silent,Silent rs10121150 9 116131695 [A/G] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY Silent,Silent,Silent rs3827661 9 116131873 [A/C] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY Silent,Silent,Silent rs3750529 9 116132275 [A/G] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY EXON Synonymous_L354L,Silent,Synonymous_L359L rs3088235 9 116132334 [T/C] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY EXON Missense_T374I,Silent,Missense_T379I rs10817488 9 116133095 [T/C] NM_017688,NM_001317944,NM_001317943 BSPRY,BSPRY,BSPRY EXON Silent,Silent,Silent rs818713 9 116134127 [T/C] rs1043836 9 116136198 [T/C] NM_031219,NM_001304509,NM_001304510,NM_001304511 HDHD3,HDHD3,HDHD3,HDHD3 EXON Missense_G146E,Missense_G146E,Missense_G146E,Missense_G146E rs3747815 9 116137673 [A/C] NM_031219,NM_001304509,NM_001304510,NM_001304511 HDHD3,HDHD3,HDHD3,HDHD3 Silent,Silent,Silent,Silent rs3747816 9 116138013 [T/C] NM_031219,NM_001304509,NM_001304510,NM_001304511 HDHD3,HDHD3,HDHD3,HDHD3 EXON Silent,Silent,Silent,Silent rs16936474 9 116139835 [A/G] rs818702 9 116144973 [A/G] rs818706 9 116148630 [T/C] NM_001317745,NM_000031,NM_001003945 ALAD,ALAD,ALAD EXON Silent,Silent,Silent rs8177822 9 116149709 [T/G] NM_001317745,NM_000031,NM_001003945 ALAD,ALAD,ALAD EXON Silent,Silent,Silent rs818708 9 116150109 [A/G] NM_001317745,NM_000031,NM_001003945 ALAD,ALAD,ALAD EXON Silent,Silent,Silent rs1805313 9 116151191 [A/G] NM_001317745,NM_000031,NM_001003945 ALAD,ALAD,ALAD Silent,Silent,Silent rs8177812 9 116151527 [A/G] NM_001317745,NM_000031,NM_001003945 ALAD,ALAD,ALAD Silent,Silent,Silent rs2228083 9 116152940 [A/G] NM_001317745,NM_000031,NM_001003945 ALAD,ALAD,ALAD EXON Synonymous_N130N,Synonymous_N138N,Synonymous_N167N rs2761016 9 116153352 [T/C] NM_001317745,NM_000031,NM_001003945 ALAD,ALAD,ALAD Silent,Silent,Silent rs8177796 9 116155428 [A/G] NM_001317745,NM_000031,NM_001003945 ALAD,ALAD,ALAD Silent,Silent,Silent rs818684 9 116159423 [T/C] NM_001317745,NM_000031,NM_001003945 ALAD,ALAD,ALAD Silent,Silent,Silent rs7021649 9 116162375 [A/G] NM_001317745,NM_000031,NM_001003945 ALAD,ALAD,ALAD Silent,Silent,Silent rs818689 9 116162760 [T/C] NM_001317745,NM_000031,NM_001003945 ALAD,ALAD,ALAD Silent,Silent,Silent rs1771221 9 116163118 [A/C] NM_001317745,NM_000031,NM_001003945 ALAD,ALAD,ALAD Silent,Silent,Silent rs2761029 9 116164351 [A/G] rs35654915 9 116170227 [A/G] NM_017443,NR_027261,NM_001278255 POLE3,POLE3,POLE3 EXON Silent,Silent,Silent rs3827674 9 116171275 [A/G] NM_017443,NR_027261,NM_001278255 POLE3,POLE3,POLE3 Silent,Silent,Silent rs3810925 9 116173206 [A/G] NM_001278629,NM_152786,NM_001278630 C9orf43,C9orf43,C9orf43 EXON Silent,Silent,Silent rs818714 9 116183301 [A/G] NM_001278629,NM_152786,NM_001278630 C9orf43,C9orf43,C9orf43 Silent,Silent,Silent rs10116799 9 116184307 [T/C] NM_001278629,NM_152786,NM_001278630 C9orf43,C9orf43,C9orf43 Silent,Silent,Silent rs7021688 9 116190841 [T/C] NM_001278629,NM_152786,NM_001278630 C9orf43,C9orf43,C9orf43 Silent,Silent,Silent rs1318368 9 116191827 [T/G] NM_001278629,NM_152786,NM_001278630 C9orf43,C9orf43,C9orf43 EXON Silent,Silent,Silent rs1578592 9 116194436 [A/G] rs12338788 9 116214058 [A/G] NM_144488 RGS3 Silent rs16933949 9 116224452 [A/G] NM_144488 RGS3 EXON Missense_R129K rs7866866 9 116248062 [T/G] NM_144488,NM_001282923,NM_017790 RGS3,RGS3,RGS3 Silent,Silent,Silent rs3761820 9 116266704 [A/G] NM_144488,NM_001282923,NM_017790,NM_130795,NM_001276261,NM_001322214 RGS3,RGS3,RGS3,RGS3,RGS3,RGS3 Silent,Silent,Silent,Silent,Silent,Silent rs12342699 9 116282114 [A/G] NM_144488,NM_001282923,NM_017790,NM_130795,NM_001276261,NM_001322214 RGS3,RGS3,RGS3,RGS3,RGS3,RGS3 Silent,Silent,Silent,Silent,Silent,Silent rs7855434 9 116288537 [T/C] NM_144488,NM_001282923,NM_017790,NM_130795,NM_001276261,NM_001322214 RGS3,RGS3,RGS3,RGS3,RGS3,RGS3 Silent,Silent,Silent,Silent,Silent,Silent rs7046427 9 116289417 [A/G] NM_144488,NM_001282923,NM_017790,NM_130795,NM_001276261,NM_001322214 RGS3,RGS3,RGS3,RGS3,RGS3,RGS3 Silent,Silent,Silent,Silent,Silent,Silent rs7851718 9 116304165 [A/G] NM_144488,NM_001282923,NM_017790,NM_130795,NM_001276261,NM_001322214,NM_001276260 RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7851937 9 116304304 [A/G] NM_144488,NM_001282923,NM_017790,NM_130795,NM_001276261,NM_001322214,NM_001276260 RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10981818 9 116308709 [T/G] NM_144488,NM_001282923,NM_130795,NM_001276261,NM_001276260 RGS3,RGS3,RGS3,RGS3,RGS3 Silent,Silent,Silent,Silent,Silent rs4979257 9 116334777 [A/G] NM_144488,NM_001282923,NM_130795,NM_001276261,NM_001276260,NM_001351526,NM_134427,NM_001322215 RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12339493 9 116343044 [A/G] NM_144488,NM_001282923,NM_130795,NM_001276261,NM_001276260,NM_001351526,NM_134427,NM_001322215 RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3810927 9 116346287 [T/C] NM_144488,NM_001282923,NM_130795,NM_001276261,NM_001276260,NM_001351526,NM_134427,NM_001322215,NM_001282922 RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3 EXON Synonymous_Y865Y,Synonymous_Y755Y,Synonymous_Y584Y,Silent,Synonymous_Y186Y,Synonymous_Y186Y,Silent,Synonymous_Y204Y,Synonymous_Y186Y rs10981835 9 116349298 [A/G] NM_144488,NM_001282923,NM_130795,NM_001276261,NM_001276260,NM_001351526,NM_134427,NM_001322215,NM_001282922 RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4979261 9 116355415 [A/G] NM_144488,NM_001282923,NM_130795,NM_001276261,NM_001276260,NM_001351526,NM_134427,NM_001322215,NM_001282922 RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3,RGS3 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17187621 9 116362738 [A/G] rs518636 9 116363146 [A/G] rs10817494 9 116365451 [T/G] rs514309 9 116372579 [A/C] rs482318 9 116373700 [T/C] rs590963 9 116374874 [T/C] rs586265 9 116378169 [A/G] rs611335 9 116384750 [T/C] rs569679 9 116386438 [A/C] rs540599 9 116387254 [T/C] rs670719 9 116388816 [A/G] rs2127744 9 116391069 [A/G] rs2127745 9 116391162 [T/C] rs658580 9 116399607 [A/C] rs7862785 9 116400152 [A/C] rs4978549 9 116400936 [T/G] rs10981854 9 116403013 [A/C] rs584190 9 116404703 [T/C] rs7873198 9 116405376 [T/C] rs13297834 9 116405475 [T/C] rs2812401 9 116405568 [T/C] rs7862521 9 116406907 [T/G] rs7862352 9 116407044 [A/G] rs7035632 9 116407227 [T/G] rs602569 9 116409528 [A/G] rs6478027 9 116410383 [A/G] rs681218 9 116411416 [T/C] rs13291990 9 116411753 [T/C] rs7864770 9 116412663 [A/G] rs10981859 9 116413354 [A/G] rs10817497 9 116413751 [T/C] rs618624 9 116416163 [A/G] rs1077072 9 116418881 [T/C] rs2622266 9 116420246 [T/C] rs2101069 9 116421786 [T/C] rs586397 9 116432208 [A/G] rs536984 9 116432952 [T/C] rs10117193 9 116433501 [T/C] rs12683799 9 116433507 [A/G] rs784935 9 116434346 [T/G] rs784932 9 116435724 [A/G] rs3860173 9 116436877 [T/C] rs554920 9 116438047 [T/C] rs7852392 9 116439749 [A/G] rs486257 9 116441589 [T/C] rs7860671 9 116441603 [T/C] rs9644931 9 116443721 [T/C] rs4979274 9 116444269 [A/C] rs16907988 9 116445988 [A/C] rs3904317 9 116446881 [A/G] rs586348 9 116447723 [A/G] rs10981887 9 116449553 [T/G] rs7855534 9 116453001 [T/C] rs11999448 9 116460731 [T/C] rs10981892 9 116461477 [A/G] rs10817507 9 116462317 [T/C] rs2170226 9 116464160 [T/C] rs16908163 9 116468123 [T/C] rs10123403 9 116468685 [A/G] rs10817510 9 116475151 [T/C] rs7852684 9 116477070 [A/G] rs10981899 9 116478405 [T/G] rs10123658 9 116486584 [T/C] rs1326328 9 116493215 [T/G] rs7866229 9 116495444 [T/G] rs10817516 9 116498284 [A/C] rs10817517 9 116499027 [T/C] rs1871692 9 116501277 [A/C] rs16908707 9 116506211 [A/G] rs9792536 9 116506979 [T/G] rs7045057 9 116507666 [A/G] rs12003007 9 116508048 [T/C] rs7847036 9 116508649 [A/C] rs7866886 9 116509853 [T/C] rs7032818 9 116512100 [A/G] rs16908855 9 116514497 [T/C] rs10981912 9 116517302 [A/C] rs10513213 9 116519285 [A/G] rs10981914 9 116521430 [A/G] rs7868736 9 116528183 [T/C] rs1994002 9 116530593 [T/C] rs16909256 9 116535326 [A/G] rs1359637 9 116535410 [T/C] rs1022949 9 116545758 [T/C] rs7030473 9 116553683 [A/G] rs913080 9 116555563 [T/C] rs10817520 9 116555661 [T/C] rs10817521 9 116557588 [A/G] rs7037774 9 116560635 [A/G] rs988015 9 116564763 [T/C] rs10981934 9 116565746 [A/G] rs10981940 9 116573081 [A/G] rs10981943 9 116577117 [A/G] rs10981955 9 116591472 [A/G] rs7866200 9 116610361 [T/C] rs1330165 9 116629769 [T/C] rs4978557 9 116635490 [A/G] rs1330172 9 116637929 [T/G] rs10759662 9 116651267 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs1999203 9 116652328 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs17200294 9 116660999 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs10982000 9 116668012 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs2150014 9 116668681 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs7038501 9 116670142 [T/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs7034929 9 116672801 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs7852787 9 116680454 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs882980 9 116683645 [T/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs4979298 9 116684240 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs4979304 9 116692683 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs10513223 9 116697000 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs871807 9 116698630 [A/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs10448275 9 116702866 [T/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs11791817 9 116704466 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs11792006 9 116708823 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs12551845 9 116710512 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs7853673 9 116711241 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs1571578 9 116715090 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs7046776 9 116715706 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs10982017 9 116722693 [T/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs814694 9 116723095 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs1544102 9 116723488 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs16911006 9 116724402 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs10817542 9 116725481 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs16911010 9 116725719 [T/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs4979309 9 116726904 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs1544065 9 116733183 [T/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs7047767 9 116733480 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs7021972 9 116735001 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs10982023 9 116736791 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs12349112 9 116737382 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs12351979 9 116739981 [T/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs860082 9 116742335 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs1006541 9 116745655 [T/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs11787940 9 116748909 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs4979310 9 116749297 [T/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs10817547 9 116751850 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs11791155 9 116752771 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs700125 9 116763905 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs4978561 9 116764283 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 EXON Synonymous_Y147Y,Synonymous_Y115Y,Synonymous_Y115Y,Synonymous_Y115Y rs942288 9 116766112 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs7858120 9 116766695 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs4978562 9 116768637 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs2025391 9 116770186 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs10982031 9 116776289 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs1853546 9 116778644 [T/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs10817557 9 116779813 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs4979325 9 116780314 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs4979326 9 116780465 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs13297916 9 116780559 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs1323789 9 116780600 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs7023951 9 116780992 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs10982035 9 116782921 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs10982039 9 116789571 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs10125470 9 116789690 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs7040743 9 116790352 [T/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs10759679 9 116790511 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs7030167 9 116791161 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 EXON Synonymous_C331C,Synonymous_C299C,Synonymous_C299C,Silent rs10121424 9 116800606 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs10124293 9 116800860 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs12555049 9 116805634 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs1008138 9 116809470 [A/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 Silent,Silent,Silent,Silent rs12378906 9 116810204 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 EXON Synonymous_Q426Q,Synonymous_Q394Q,Synonymous_Q393Q,Synonymous_Q333Q rs7856141 9 116812084 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 EXON Synonymous_N834N,Synonymous_N802N,Synonymous_N801N,Synonymous_N741N rs7037095 9 116814126 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 EXON Silent,Silent,Silent,Silent rs12683020 9 116814661 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 EXON Silent,Silent,Silent,Silent rs3810928 9 116815777 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 EXON Silent,Silent,Silent,Silent rs6478053 9 116815971 [T/C] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 EXON Silent,Silent,Silent,Silent rs10739400 9 116816816 [A/G] NM_001318042,NM_001318041,NM_001318040,NM_133374 ZNF618,ZNF618,ZNF618,ZNF618 EXON Silent,Silent,Silent,Silent rs3860175 9 116821526 [T/C] rs7034903 9 116825675 [A/G] NM_001633 AMBP Silent rs10759680 9 116825745 [T/C] NM_001633 AMBP Silent rs10817563 9 116826842 [A/C] NM_001633 AMBP Silent rs12344124 9 116837745 [T/G] NM_001633 AMBP Silent rs2567698 9 116837945 [T/C] NM_001633 AMBP Silent rs2567700 9 116838743 [A/C] NM_001633 AMBP Silent rs2251680 9 116840204 [A/G] NM_001633 AMBP Silent rs2285055 9 116841180 [T/C] rs13283242 9 116844869 [T/G] rs16912505 9 116844924 [A/G] rs891725 9 116847201 [T/C] rs891724 9 116847365 [A/G] rs7862938 9 116849069 [T/C] rs728071 9 116849447 [A/G] rs10817565 9 116850345 [A/G] rs2093785 9 116851076 [A/G] rs7854030 9 116853797 [A/G] rs1886128 9 116861763 [A/G] rs2418265 9 116865784 [A/G] rs7856692 9 116866605 [A/G] rs7029198 9 116867054 [A/G] rs2900573 9 116870232 [A/C] rs2900574 9 116870327 [T/C] rs7047941 9 116872524 [T/C] rs10759682 9 116873183 [A/C] rs1570589 9 116874355 [A/G] rs4978567 9 116880005 [A/G] rs10982068 9 116880031 [A/G] rs7856967 9 116887405 [A/C] rs7857688 9 116887845 [A/G] rs2418267 9 116890596 [A/G] rs11788110 9 116891825 [T/C] rs13300798 9 116895387 [T/C] rs891721 9 116896966 [A/G] rs891720 9 116897213 [A/C] rs2761687 9 116899258 [A/C] rs1017360 9 116901926 [A/G] rs7868176 9 116902782 [A/G] rs737174 9 116903410 [A/C] rs2043195 9 116904534 [T/C] rs10817573 9 116907448 [A/G] rs2002284 9 116908453 [A/G] rs10739403 9 116913145 [T/C] rs919641 9 116913717 [T/C] rs2808772 9 116913794 [A/G] rs1469599 9 116916904 [T/G] rs1469598 9 116916931 [A/G] rs2808781 9 116920024 [T/C] NM_032888 COL27A1 Silent rs2808785 9 116921849 [T/C] NM_032888 COL27A1 Silent rs891727 9 116923333 [T/C] NM_032888 COL27A1 Silent rs737142 9 116929327 [T/C] NM_032888 COL27A1 Silent rs2567707 9 116930100 [A/G] NM_032888 COL27A1 EXON Missense_V89I rs2567706 9 116930194 [A/G] NM_032888 COL27A1 EXON Missense_Q120R rs2808770 9 116931445 [T/C] NM_032888 COL27A1 EXON Missense_I537T rs2567705 9 116931666 [T/A] NM_032888 COL27A1 EXON Missense_I611F rs2808771 9 116931737 [T/C] NM_032888 COL27A1 EXON Synonymous_G634G rs2567704 9 116932906 [A/G] NM_032888 COL27A1 Silent rs2808777 9 116934281 [T/C] NM_032888 COL27A1 Silent rs10982093 9 116936905 [A/C] NM_032888 COL27A1 Silent rs10759684 9 116937667 [T/C] NM_032888 COL27A1 Silent rs10759685 9 116939620 [A/G] NM_032888 COL27A1 Silent rs13295426 9 116940418 [A/C] NM_032888 COL27A1 Silent rs13295729 9 116940489 [T/C] NM_032888 COL27A1 Silent rs3810930 9 116940594 [A/G] NM_032888 COL27A1 EXON Synonymous_L644L rs3827676 9 116941019 [T/C] NM_032888 COL27A1 Silent rs12001466 9 116942796 [T/G] NM_032888 COL27A1 Silent rs10759686 9 116944333 [T/C] NM_032888 COL27A1 Silent rs10759687 9 116944847 [A/G] NM_032888 COL27A1 Silent rs10759688 9 116945454 [A/C] NM_032888 COL27A1 Silent rs10982094 9 116947947 [A/G] NM_032888 COL27A1 Silent rs891718 9 116949449 [T/C] NM_032888 COL27A1 Silent rs10817578 9 116951459 [A/C] NM_032888 COL27A1 Silent rs2808788 9 116958646 [T/G] NM_032888 COL27A1 Silent rs2567712 9 116961156 [T/G] NM_032888 COL27A1 Silent rs2567713 9 116963876 [T/C] NM_032888 COL27A1 Silent rs2567714 9 116964061 [T/C] NM_032888 COL27A1 Silent rs2567716 9 116965542 [A/G] NM_032888 COL27A1 Silent rs2567719 9 116967263 [T/G] NM_032888 COL27A1 Silent rs13290696 9 116967405 [T/G] NM_032888 COL27A1 EXON Synonymous_P716P rs2567720 9 116967952 [T/C] NM_032888 COL27A1 Silent rs12001716 9 116971384 [T/G] NM_032888 COL27A1 Silent rs10982107 9 116972955 [T/G] NM_032888 COL27A1 Silent rs4979354 9 116973755 [A/G] NM_032888 COL27A1 Silent rs13300252 9 116974295 [A/G] NM_032888 COL27A1 Silent rs10119877 9 116978430 [T/C] NM_032888 COL27A1 Silent rs7870474 9 116979172 [T/C] NM_032888 COL27A1 Silent rs10982110 9 116980052 [T/C] NM_032888 COL27A1 Silent rs10513237 9 116980821 [A/G] NM_032888 COL27A1 Silent rs7027825 9 116985526 [T/C] NM_032888 COL27A1 Silent rs16927476 9 116986741 [T/C] NM_032888 COL27A1 Silent rs7855833 9 116987587 [A/C] NM_032888 COL27A1 Silent rs871878 9 116989375 [T/G] NM_032888 COL27A1 Silent rs902496 9 116989776 [T/G] NM_032888 COL27A1 Silent rs11794759 9 116989900 [A/G] NM_032888 COL27A1 Silent rs1060501 9 116990267 [T/C] NM_032888 COL27A1 Silent rs4979357 9 116990995 [T/C] NM_032888 COL27A1 Silent rs7868992 9 116991071 [A/G] NM_032888 COL27A1 Silent rs902494 9 116994025 [A/G] NM_032888 COL27A1 Silent rs7875159 9 116995483 [T/G] NM_032888 COL27A1 Silent rs7021841 9 116996533 [T/C] NM_032888 COL27A1 Silent rs10982118 9 116997048 [A/G] NM_032888 COL27A1 Silent rs1249715 9 117000687 [A/G] NM_032888 COL27A1 Silent rs1982850 9 117000801 [A/G] NM_032888 COL27A1 Silent rs7875437 9 117004955 [A/G] NM_032888 COL27A1 Silent rs7850171 9 117005624 [T/G] NM_032888 COL27A1 Silent rs1048469 9 117009115 [A/G] NM_032888 COL27A1 Silent rs2029522 9 117009953 [A/G] NM_032888 COL27A1 Silent rs1249710 9 117010405 [A/C] NM_032888 COL27A1 Silent rs999599 9 117011595 [T/C] NM_032888 COL27A1 Silent rs7038559 9 117015163 [A/G] NM_032888 COL27A1 EXON Missense_H1031R rs10982124 9 117015956 [A/G] NM_032888 COL27A1 Silent rs4979361 9 117019167 [T/C] NM_032888 COL27A1 Silent rs923601 9 117019801 [T/C] NM_032888 COL27A1 Silent rs7869221 9 117021282 [A/G] NM_032888 COL27A1 Silent rs10732377 9 117022495 [A/C] NM_032888 COL27A1 Silent rs923602 9 117022609 [T/C] NM_032888 COL27A1 Silent rs2418268 9 117023606 [T/C] NM_032888 COL27A1 Silent rs7851927 9 117024083 [T/C] NM_032888 COL27A1 Silent rs2808768 9 117024142 [T/G] NM_032888 COL27A1 Silent rs2636856 9 117024515 [A/G] NM_032888 COL27A1 Silent rs2418269 9 117024627 [A/G] NM_032888 COL27A1 Silent rs1623718 9 117027068 [T/C] NM_032888 COL27A1 Silent rs7048607 9 117027709 [A/C] NM_032888 COL27A1 EXON Missense_P1116Q rs7027370 9 117030261 [A/G] NM_032888 COL27A1 Silent rs2636860 9 117030582 [A/G] NM_032888 COL27A1 Silent rs2491426 9 117032111 [T/C] NM_032888 COL27A1 Silent rs5003737 9 117032189 [A/G] NM_032888 COL27A1 Silent rs1490740 9 117032261 [T/C] NM_032888 COL27A1 Silent rs1490741 9 117032340 [A/G] NM_032888 COL27A1 Silent rs4143245 9 117033022 [T/C] NM_032888 COL27A1 EXON Synonymous_L1190L rs10982127 9 117033379 [A/G] NM_032888 COL27A1 Silent rs10982130 9 117034510 [A/G] NM_032888 COL27A1 Silent rs10982133 9 117034674 [A/G] NM_032888 COL27A1 Silent rs1490742 9 117034749 [T/C] NM_032888 COL27A1 Silent rs12115652 9 117035177 [A/G] NM_032888 COL27A1 Silent rs1490743 9 117036047 [T/G] NM_032888 COL27A1 Silent rs1766059 9 117039111 [A/G] NM_032888 COL27A1 Silent rs10817580 9 117039222 [A/G] NM_032888 COL27A1 Silent rs1249745 9 117042977 [T/C] NM_032888 COL27A1 Silent rs1249744 9 117043352 [A/G] NM_032888 COL27A1 Silent rs1628968 9 117044458 [A/G] NM_032888 COL27A1 Silent rs4381012 9 117047502 [A/G] NM_032888 COL27A1 Silent rs2130722 9 117047888 [T/C] NM_032888 COL27A1 Silent rs4978577 9 117048609 [T/C] NM_032888 COL27A1 Silent rs946053 9 117049891 [T/G] NM_032888 COL27A1 Silent rs10982134 9 117050998 [A/G] NM_032888 COL27A1 EXON Missense_R1354Q rs1687410 9 117051020 [A/G] NM_032888 COL27A1 EXON Synonymous_G1361G rs1249738 9 117053215 [A/G] NM_032888 COL27A1 Silent rs10429546 9 117054195 [A/C] NM_032888 COL27A1 Silent rs4979365 9 117060746 [T/C] NM_032888 COL27A1 Silent rs1687401 9 117061237 [T/C] NM_032888 COL27A1 Silent rs1626295 9 117062677 [T/C] NM_032888 COL27A1 Silent rs1546049 9 117064306 [T/C] NM_032888 COL27A1 Silent rs12553004 9 117065386 [A/G] NM_032888 COL27A1 Silent rs10817588 9 117066040 [A/G] NM_032888 COL27A1 Silent rs10817589 9 117066118 [A/G] NM_032888 COL27A1 Silent rs10759690 9 117066467 [T/G] NM_032888 COL27A1 Silent rs10817590 9 117066823 [T/C] NM_032888 COL27A1 Silent rs1249762 9 117068826 [A/G] NM_032888 COL27A1 EXON Synonymous_V1655V rs1249755 9 117073325 [A/G] NM_032888 COL27A1 EXON Silent rs11537824 9 117073588 [A/G] NM_032888 COL27A1 EXON Silent rs10982144 9 117075811 [T/C] rs1631637 9 117076684 [T/C] rs7851482 9 117078286 [T/G] rs2787334 9 117078838 [T/C] rs2636885 9 117079287 [A/G] rs2636881 9 117080388 [A/G] rs2787337 9 117084228 [T/C] rs1111796 9 117086226 [A/G] NM_000607 ORM1 Silent rs10982151 9 117086271 [T/G] NM_000607 ORM1 Silent rs17230081 9 117093029 [T/C] NM_000608 ORM2 Silent rs2636889 9 117093110 [T/C] NM_000608 ORM2 EXON Missense_V99A rs10739407 9 117097755 [T/C] rs1044531 9 117098650 [T/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA EXON Silent,Silent,Silent rs1687392 9 117099956 [A/G] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs10982171 9 117099995 [T/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs2636870 9 117102046 [A/G] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs2787344 9 117103900 [T/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA EXON Missense_Y1327C,Missense_Y1208C,Missense_Y1327C rs2250242 9 117103973 [A/G] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA EXON Missense_S1303P,Missense_S1184P,Missense_S1303P rs16928348 9 117106136 [T/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs902492 9 117108971 [T/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA EXON Synonymous_R1164R,Synonymous_R1045R,Synonymous_R1164R rs3748178 9 117110046 [T/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA EXON Missense_R1119Q,Missense_R1000Q,Missense_R1119Q rs1265891 9 117110112 [T/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA EXON Missense_Q1097R,Missense_Q978R,Missense_Q1097R rs2787346 9 117111707 [A/G] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs10817593 9 117111951 [T/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs1249725 9 117112814 [T/G] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs1766069 9 117112886 [T/G] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs10982177 9 117114168 [T/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs16928440 9 117120384 [A/G] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA EXON Synonymous_D852D,Synonymous_D733D,Synonymous_D852D rs7866925 9 117120680 [T/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs2787348 9 117121840 [A/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs2636897 9 117122615 [A/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs10817594 9 117123494 [T/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs12337816 9 117125236 [T/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs10125969 9 117126307 [T/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs1535958 9 117137410 [A/G] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs10739409 9 117148327 [T/C] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs10733608 9 117148430 [T/G] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs2787328 9 117149218 [T/G] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs1324632 9 117150070 [A/G] NM_030767,NM_001317952,NM_001317950 AKNA,AKNA,AKNA Silent,Silent,Silent rs2763196 9 117150951 [A/G] NM_030767,NM_001317952 AKNA,AKNA Silent,Silent rs12351392 9 117153206 [A/C] NM_030767,NM_001317952 AKNA,AKNA Silent,Silent rs4979375 9 117156596 [T/C] NM_030767,NM_001317952 AKNA,AKNA Silent,Silent rs17231346 9 117157334 [T/C] rs10759692 9 117161055 [T/C] rs10759693 9 117162253 [T/C] rs10759694 9 117164006 [A/G] rs2274158 9 117166206 [T/G] NM_015404,NM_001083885,NM_001173425,NM_001346890 WHRN,WHRN,WHRN,WHRN EXON Missense_N796K,Missense_N413K,Missense_N795K,Missense_N445K rs2274159 9 117166246 [A/G] NM_015404,NM_001083885,NM_001173425,NM_001346890 WHRN,WHRN,WHRN,WHRN EXON Missense_V783A,Missense_V400A,Missense_V782A,Missense_V432A rs2236388 9 117169300 [A/G] NM_015404,NM_001083885,NM_001173425,NM_001346890 WHRN,WHRN,WHRN,WHRN Silent,Silent,Silent,Silent rs1535966 9 117174368 [A/G] NM_015404,NM_001083885,NM_001173425,NM_001346890 WHRN,WHRN,WHRN,WHRN Silent,Silent,Silent,Silent rs7849013 9 117181430 [A/G] NM_015404,NM_001083885,NM_001173425,NM_001346890 WHRN,WHRN,WHRN,WHRN Silent,Silent,Silent,Silent rs10739411 9 117183149 [A/G] NM_015404,NM_001083885,NM_001173425,NM_001346890 WHRN,WHRN,WHRN,WHRN Silent,Silent,Silent,Silent rs2181928 9 117185395 [A/G] NM_015404,NM_001083885,NM_001173425,NM_001346890 WHRN,WHRN,WHRN,WHRN Silent,Silent,Silent,Silent rs4978584 9 117186712 [T/C] NM_015404,NM_001083885,NM_001173425,NM_001346890 WHRN,WHRN,WHRN,WHRN EXON Missense_A440T,Missense_A57T,Missense_A440T,Missense_A89T rs10817610 9 117188566 [T/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN EXON Missense_R364H,Silent,Missense_R364H rs7851968 9 117194505 [A/G] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs4978587 9 117195199 [A/G] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs7044547 9 117197493 [A/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs1924683 9 117198273 [T/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs4979391 9 117200079 [T/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs10982218 9 117200140 [T/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs10513245 9 117205332 [A/G] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs10982222 9 117208985 [A/G] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs942520 9 117214909 [A/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs10739418 9 117218901 [A/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs4979397 9 117219888 [T/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs10759707 9 117222287 [A/G] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs4979402 9 117222675 [A/G] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs10217748 9 117225658 [T/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs4979407 9 117228115 [T/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs1535971 9 117229400 [T/G] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs12004144 9 117230237 [A/G] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs10817618 9 117231413 [A/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs1123056 9 117236557 [T/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs1000709 9 117237754 [T/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs16929518 9 117242599 [A/G] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs16929545 9 117245132 [A/G] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs725340 9 117249874 [A/G] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs1535960 9 117251352 [T/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs12551529 9 117256896 [A/G] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs1535962 9 117259062 [T/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs4979418 9 117264083 [A/G] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN Silent,Silent,Silent rs2296262 9 117265406 [T/C] NM_015404,NM_001083885,NM_001173425 WHRN,WHRN,WHRN EXON Silent,Silent,Silent rs942518 9 117272858 [A/G] rs998547 9 117275012 [A/G] rs10513248 9 117278844 [T/C] rs2770154 9 117282390 [A/G] rs1272624 9 117283232 [T/C] rs9987813 9 117287334 [T/C] rs10759716 9 117287928 [T/C] rs10817635 9 117288169 [A/C] rs16929887 9 117289286 [A/G] rs4978594 9 117289895 [A/C] rs7869354 9 117300918 [T/G] rs13299937 9 117305350 [A/G] rs7849274 9 117306799 [A/G] rs4979424 9 117309052 [T/C] rs10982285 9 117312703 [T/C] rs10982289 9 117314774 [A/G] rs10114562 9 117315880 [A/C] rs16930078 9 117317441 [A/G] rs7855043 9 117318726 [A/G] rs10817638 9 117322542 [A/G] rs4979427 9 117323426 [T/C] rs4979428 9 117324845 [A/G] rs7851259 9 117325336 [A/G] rs10982300 9 117339877 [T/C] rs12238437 9 117348466 [A/G] rs10982317 9 117349653 [A/G] rs10124511 9 117353464 [A/G] NM_004888 ATP6V1G1 Silent rs2274595 9 117354943 [A/G] NM_004888 ATP6V1G1 Silent rs7868842 9 117360729 [T/C] NM_004888 ATP6V1G1 EXON Silent rs10115585 9 117370196 [A/C] rs4978600 9 117370538 [T/C] rs4979444 9 117375909 [A/C] NM_001330760,NM_153045 TMEM268,TMEM268 Silent,Silent rs7027695 9 117383919 [A/G] NM_001330760,NM_153045 TMEM268,TMEM268 Silent,Silent rs7036626 9 117385992 [A/G] NM_001330760,NM_153045 TMEM268,TMEM268 Silent,Silent rs1536738 9 117391325 [A/G] NM_001330760,NM_153045 TMEM268,TMEM268 Silent,Silent rs4978602 9 117393736 [T/C] NM_001330760,NM_153045 TMEM268,TMEM268 Silent,Silent rs2418310 9 117393934 [T/C] NM_001330760,NM_153045 TMEM268,TMEM268 Silent,Silent rs12379659 9 117394595 [A/G] NM_001330760,NM_153045 TMEM268,TMEM268 Silent,Silent rs10982340 9 117394754 [T/C] NM_001330760,NM_153045 TMEM268,TMEM268 Silent,Silent rs3810935 9 117396237 [T/C] NM_001330760,NM_153045 TMEM268,TMEM268 Silent,Silent rs7027937 9 117405189 [T/C] NM_001330760,NM_153045 TMEM268,TMEM268 Silent,Silent rs1058278 9 117406601 [A/G] NM_001330760,NM_153045 TMEM268,TMEM268 EXON Silent,Silent rs10759728 9 117406965 [A/G] NM_001330760,NM_153045 TMEM268,TMEM268 EXON Silent,Silent rs16936510 9 117407859 [A/C] NM_001330760,NM_153045 TMEM268,TMEM268 EXON Silent,Silent rs1058280 9 117407923 [T/C] NM_001330760,NM_153045 TMEM268,TMEM268 EXON Silent,Silent rs12005760 9 117409060 [A/C] rs16930630 9 117422620 [A/G] rs2274599 9 117424855 [A/G] rs2282003 9 117429227 [A/G] NR_133056,NR_144867,NM_001199233 TEX48,TEX48,TEX48 Silent,Silent,Silent rs2296947 9 117430524 [A/G] NR_133056,NR_144867,NM_001199233 TEX48,TEX48,TEX48 EXON Silent,Silent,Missense_T74I rs11793719 9 117432041 [T/G] NR_133056,NR_144867,NM_001199233 TEX48,TEX48,TEX48 Silent,Silent,Silent rs7846979 9 117432944 [T/C] NR_133056,NR_144867,NM_001199233 TEX48,TEX48,TEX48 Silent,Silent,Silent rs2296948 9 117433685 [T/C] NR_133056,NR_144867,NM_001199233 TEX48,TEX48,TEX48 EXON Silent,Silent,Synonymous_Q35Q rs4978604 9 117434799 [A/G] NR_133056,NR_144867,NM_001199233 TEX48,TEX48,TEX48 Silent,Silent,Silent rs16930798 9 117440143 [A/G] NR_133056,NR_144867,NM_001199233 TEX48,TEX48,TEX48 Silent,Silent,Silent rs6478100 9 117442123 [T/C] NR_133056,NR_144867,NM_001199233 TEX48,TEX48,TEX48 Silent,Silent,Silent rs13286744 9 117444227 [T/C] NR_133056,NR_144867,NM_001199233 TEX48,TEX48,TEX48 Silent,Silent,Silent rs1075371 9 117444370 [A/C] rs10982370 9 117445168 [A/G] rs7853853 9 117448713 [A/G] rs10739424 9 117450244 [T/C] rs7039257 9 117451913 [A/G] rs16930907 9 117453668 [T/C] rs16930926 9 117456045 [T/G] rs17816047 9 117464374 [A/C] rs7850846 9 117472937 [A/C] rs4979458 9 117478697 [T/C] rs4979459 9 117481666 [T/G] rs10817669 9 117483015 [A/G] rs7026324 9 117483943 [A/G] rs11790825 9 117491859 [A/G] rs10982385 9 117493017 [T/G] rs2185935 9 117502242 [T/C] rs2068955 9 117504798 [A/G] rs7038398 9 117516418 [A/C] rs10982395 9 117517897 [T/C] rs12683136 9 117523018 [T/C] rs10759736 9 117523192 [A/G] rs10513258 9 117530133 [T/G] rs4978609 9 117530319 [A/G] rs7032238 9 117533062 [A/G] rs7048659 9 117533289 [T/C] rs12238270 9 117535054 [T/G] rs16931595 9 117537156 [A/G] rs7856856 9 117540910 [T/C] rs7860414 9 117541450 [T/C] rs6478106 9 117545666 [T/C] rs10114470 9 117547772 [T/C] NM_005118,NM_001204344 TNFSF15,TNFSF15 EXON Silent,Silent rs12682881 9 117551453 [T/C] NM_005118,NM_001204344 TNFSF15,TNFSF15 EXON Silent,Silent rs3810936 9 117552885 [T/C] NM_005118,NM_001204344 TNFSF15,TNFSF15 EXON Synonymous_V201V,Synonymous_V142V rs7867918 9 117557872 [T/G] NM_005118 TNFSF15 Silent rs6478108 9 117558703 [T/C] NM_005118 TNFSF15 Silent rs7847158 9 117560265 [A/G] NM_005118 TNFSF15 Silent rs4263839 9 117566440 [A/G] NM_005118 TNFSF15 Silent rs4979462 9 117567013 [T/C] NM_005118 TNFSF15 Silent rs7862325 9 117567137 [T/C] NM_005118 TNFSF15 Silent rs6478109 9 117568766 [A/G] rs7848647 9 117569046 [T/C] rs10982412 9 117570856 [A/G] rs12002641 9 117573803 [T/G] rs2208641 9 117582029 [A/G] rs7868351 9 117584082 [T/G] rs1322063 9 117585482 [A/G] rs2006996 9 117592638 [T/C] rs34187507 9 117597885 [T/G] rs11554257 9 117605070 [T/C] rs12350737 9 117608270 [T/C] rs16931895 9 117609919 [A/C] rs12336469 9 117611886 [T/C] rs7037755 9 117616813 [A/G] rs10982432 9 117618373 [T/C] rs7866342 9 117627569 [T/G] rs4979467 9 117630043 [T/C] rs7874896 9 117636879 [T/G] rs13300483 9 117643362 [T/C] rs12004499 9 117643711 [T/C] rs7028891 9 117645015 [A/G] rs1407309 9 117651780 [A/G] rs1322067 9 117660933 [A/G] NM_001252290 TNFSF8 Silent rs2295800 9 117664211 [T/C] NM_001252290,NM_001244 TNFSF8,TNFSF8 EXON Silent,Silent rs3181372 9 117665435 [A/G] NM_001252290,NM_001244 TNFSF8,TNFSF8 EXON Silent,Silent rs3181369 9 117665866 [A/G] NM_001252290,NM_001244 TNFSF8,TNFSF8 EXON Silent,Silent rs3181362 9 117667443 [T/C] NM_001252290,NM_001244 TNFSF8,TNFSF8 Silent,Silent rs3181195 9 117668142 [T/C] NM_001252290,NM_001244 TNFSF8,TNFSF8 EXON Synonymous_R92R,Synonymous_R92R rs1322055 9 117669585 [T/C] NM_001252290,NM_001244 TNFSF8,TNFSF8 Silent,Silent rs1555457 9 117674320 [T/C] NM_001252290,NM_001244 TNFSF8,TNFSF8 Silent,Silent rs2418326 9 117679474 [T/C] NM_001252290,NM_001244 TNFSF8,TNFSF8 Silent,Silent rs4979472 9 117685398 [A/G] NM_001252290,NM_001244 TNFSF8,TNFSF8 Silent,Silent rs3181360 9 117691558 [T/C] NM_001252290,NM_001244 TNFSF8,TNFSF8 Silent,Silent rs3181192 9 117695094 [T/C] rs726657 9 117696336 [T/C] rs17292115 9 117699745 [A/C] rs10817686 9 117699850 [T/C] rs4979476 9 117700710 [A/G] rs10759743 9 117701752 [A/G] rs11791315 9 117704155 [T/G] rs10817689 9 117708099 [T/C] rs10817691 9 117720262 [A/C] rs12236266 9 117722283 [T/C] rs1265918 9 117722690 [T/C] rs7853354 9 117723333 [T/C] rs12005854 9 117727390 [A/G] rs10123153 9 117728895 [T/G] rs10982474 9 117739612 [T/C] rs10982475 9 117739703 [T/C] rs12342713 9 117740248 [A/G] rs10982476 9 117741304 [T/C] rs11787779 9 117741340 [A/G] rs1012823 9 117743178 [T/G] rs1330367 9 117744430 [A/G] rs4979482 9 117750277 [T/C] rs10817694 9 117753004 [A/G] rs16932027 9 117754106 [T/C] rs10982482 9 117755353 [A/G] rs17817825 9 117757075 [A/C] rs17239323 9 117758092 [T/C] rs4979488 9 117766101 [A/C] rs10759751 9 117768021 [A/G] rs4979489 9 117768680 [T/C] rs10982490 9 117768771 [T/C] rs12006094 9 117771310 [T/C] rs16932055 9 117771475 [T/C] rs16932062 9 117776052 [T/C] rs1888221 9 117778355 [A/G] rs10117421 9 117778369 [A/C] rs1330362 9 117779668 [T/C] rs1107373 9 117779933 [A/G] rs11787664 9 117781656 [T/C] rs3789875 9 117795288 [A/C] NM_002160 TNC Silent rs12347433 9 117797597 [T/C] NM_002160 TNC EXON Synonymous_R1891R rs2274750 9 117803271 [T/C] NM_002160 TNC EXON Missense_A1781T rs10759752 9 117803720 [A/G] NM_002160 TNC Silent rs12343737 9 117804027 [T/C] NM_002160 TNC Silent rs1061495 9 117804544 [T/C] NM_002160 TNC EXON Synonymous_T1734T rs953288 9 117805719 [A/C] NM_002160 TNC Silent rs10122770 9 117807508 [T/C] NM_002160 TNC Silent rs2104772 9 117808785 [A/T] NM_002160 TNC EXON Missense_I1677L rs2297181 9 117810036 [T/C] NM_002160 TNC Silent rs11789268 9 117811205 [T/C] NM_002160 TNC Silent rs1547691 9 117812400 [A/G] NM_002160 TNC Silent rs1556220 9 117812777 [T/C] NM_002160 TNC Silent rs11789200 9 117812791 [A/G] NM_002160 TNC Silent rs2150101 9 117812891 [A/C] NM_002160 TNC Silent rs7875852 9 117813335 [A/G] NM_002160 TNC Silent rs12683163 9 117815011 [T/C] NM_002160 TNC Silent rs11794797 9 117815273 [A/G] NM_002160 TNC Silent rs1330365 9 117817683 [A/G] NM_002160 TNC Silent rs1330368 9 117821026 [A/G] NM_002160 TNC Silent rs16932160 9 117829987 [A/C] NM_002160 TNC Silent rs7847271 9 117830812 [A/G] NM_002160 TNC Silent rs7043308 9 117832416 [T/C] NM_002160 TNC Silent rs11791562 9 117834493 [A/G] NM_002160 TNC Silent rs10982513 9 117834840 [T/C] NM_002160 TNC Silent rs3789871 9 117835254 [A/G] NM_002160 TNC Silent rs3748172 9 117835931 [A/G] NM_002160 TNC EXON Synonymous_A1055A rs1330351 9 117840922 [A/G] NM_002160 TNC Silent rs12340324 9 117841416 [T/C] NM_002160 TNC Silent rs2989519 9 117844239 [A/G] NM_002160 TNC Silent rs1757106 9 117845333 [T/G] NM_002160 TNC Silent rs10982515 9 117845347 [A/G] NM_002160 TNC Silent rs2274836 9 117846570 [T/C] NM_002160 TNC EXON Synonymous_E683E rs1757095 9 117848394 [T/C] NM_002160 TNC EXON Missense_Q539R rs944510 9 117853022 [T/C] NM_002160 TNC EXON Synonymous_V92V rs10982521 9 117853103 [T/C] NM_002160 TNC EXON Synonymous_S65S rs1511 9 117856114 [A/C] NM_002160 TNC Silent rs1330360 9 117856877 [A/G] NM_002160 TNC Silent rs1250027 9 117860951 [A/G] NM_002160 TNC Silent rs2988579 9 117864084 [A/C] NM_002160 TNC Silent rs2482078 9 117865376 [A/G] NM_002160 TNC Silent rs10982536 9 117869417 [T/G] NM_002160 TNC Silent rs16932230 9 117869671 [A/G] NM_002160 TNC Silent rs1250023 9 117869930 [T/C] NM_002160 TNC Silent rs10982541 9 117875747 [T/C] NM_002160 TNC Silent rs10118040 9 117879414 [A/G] NM_002160 TNC Silent rs2071520 9 117880792 [A/G] rs12380363 9 117885635 [T/C] NR_110950 LOC101928748 Silent rs10817713 9 117889206 [A/G] NR_110950 LOC101928748 Silent rs10982549 9 117889530 [A/C] NR_110950 LOC101928748 EXON Silent rs10817715 9 117896185 [A/G] NR_110950 LOC101928748 Silent rs1537722 9 117896349 [A/G] NR_110950 LOC101928748 Silent rs7021057 9 117897993 [T/C] NR_110950 LOC101928748 Silent rs2012566 9 117903975 [A/G] rs1335331 9 117904231 [A/G] NM_017418 DEC1 Silent rs7865971 9 117905403 [T/C] NM_017418 DEC1 Silent rs1414137 9 117905653 [T/C] NM_017418 DEC1 Silent rs1335334 9 117909793 [A/G] NM_017418 DEC1 Silent rs7034038 9 117910022 [T/C] NM_017418 DEC1 Silent rs6478135 9 117912654 [T/C] NM_017418 DEC1 Silent rs1537728 9 117912890 [A/G] NM_017418 DEC1 Silent rs10982560 9 117913254 [A/G] NM_017418 DEC1 Silent rs12683723 9 117913870 [A/G] NM_017418 DEC1 Silent rs12685855 9 117914221 [A/G] NM_017418 DEC1 Silent rs10982575 9 117919576 [T/C] NM_017418 DEC1 Silent rs7851086 9 117926650 [A/G] NM_017418 DEC1 Silent rs10982590 9 117927227 [T/C] NM_017418 DEC1 Silent rs7866181 9 117928419 [T/C] NM_017418 DEC1 Silent rs7024589 9 117928483 [T/C] NM_017418 DEC1 Silent rs1537725 9 117931698 [A/G] NM_017418 DEC1 Silent rs10982592 9 117932692 [T/C] NM_017418 DEC1 Silent rs4979508 9 117932816 [A/G] NM_017418 DEC1 Silent rs10817719 9 117934415 [A/G] NM_017418 DEC1 Silent rs7040243 9 117950332 [T/C] NM_017418 DEC1 Silent rs7027882 9 117951073 [T/C] NM_017418 DEC1 Silent rs1335344 9 117956575 [T/C] NM_017418 DEC1 Silent rs7851185 9 117956828 [A/G] NM_017418 DEC1 Silent rs16932349 9 117956937 [A/G] NM_017418 DEC1 Silent rs4978627 9 117962526 [A/C] NM_017418 DEC1 Silent rs4978628 9 117964656 [A/G] NM_017418 DEC1 Silent rs10759761 9 117966294 [A/C] NM_017418 DEC1 Silent rs7044001 9 117967117 [A/G] NM_017418 DEC1 Silent rs1889651 9 117970568 [T/C] NM_017418 DEC1 Silent rs4335203 9 117970824 [T/G] NM_017418 DEC1 Silent rs1335357 9 117972155 [T/C] NM_017418 DEC1 Silent rs4147052 9 117972516 [A/G] NM_017418 DEC1 Silent rs10982611 9 117975864 [A/G] NM_017418 DEC1 Silent rs13440344 9 117979360 [A/C] NM_017418 DEC1 Silent rs10817727 9 117979410 [A/G] NM_017418 DEC1 Silent rs10982615 9 117981328 [T/C] NM_017418 DEC1 Silent rs10759762 9 117983998 [T/C] NM_017418 DEC1 Silent rs10759763 9 117985994 [A/C] NM_017418 DEC1 Silent rs10982618 9 117987615 [T/G] NM_017418 DEC1 Silent rs17834626 9 117992846 [A/G] NM_017418 DEC1 Silent rs16932390 9 117992860 [A/G] NM_017418 DEC1 Silent rs2992140 9 117994565 [T/C] NM_017418 DEC1 Silent rs7874818 9 117995613 [A/C] NM_017418 DEC1 EXON Silent rs2992142 9 117996625 [T/G] NM_017418 DEC1 Silent rs10120911 9 118001034 [A/G] NM_017418 DEC1 Silent rs2989509 9 118001670 [T/C] NM_017418 DEC1 Silent rs2992145 9 118003841 [T/C] NM_017418 DEC1 Silent rs7869917 9 118007135 [A/G] NM_017418 DEC1 Silent rs10125253 9 118012841 [T/C] NM_017418 DEC1 Silent rs883402 9 118013289 [A/G] NM_017418 DEC1 Silent rs16932442 9 118022616 [T/C] NM_017418 DEC1 Silent rs4147051 9 118029484 [T/C] NM_017418 DEC1 Silent rs10817738 9 118029729 [T/C] NM_017418 DEC1 Silent rs10982650 9 118039472 [A/G] NM_017418 DEC1 Silent rs1414153 9 118042353 [A/C] NM_017418 DEC1 Silent rs7846857 9 118043489 [A/G] NM_017418 DEC1 Silent rs7039836 9 118045119 [T/C] NM_017418 DEC1 Silent rs11998787 9 118057870 [A/G] NM_017418 DEC1 Silent rs7024885 9 118063164 [A/G] NM_017418 DEC1 Silent rs1157836 9 118068722 [T/C] NM_017418 DEC1 Silent rs10982664 9 118070259 [T/C] NM_017418 DEC1 Silent rs1335335 9 118073084 [T/G] NM_017418 DEC1 Silent rs2027155 9 118081458 [T/C] NM_017418 DEC1 Silent rs11787534 9 118087739 [A/C] NM_017418 DEC1 Silent rs10817746 9 118091712 [T/C] NM_017418 DEC1 Silent rs7034237 9 118092924 [A/G] NM_017418 DEC1 Silent rs3814957 9 118093007 [T/C] NM_017418 DEC1 Silent rs7028273 9 118094992 [T/C] NM_017418 DEC1 Silent rs10982691 9 118104142 [A/G] NM_017418 DEC1 Silent rs1981499 9 118107224 [T/C] NM_017418 DEC1 Silent rs10817753 9 118107547 [A/G] NM_017418 DEC1 Silent rs10982694 9 118107565 [A/C] NM_017418 DEC1 Silent rs13300423 9 118113846 [T/C] NM_017418 DEC1 Silent rs10982704 9 118119122 [T/C] NM_017418 DEC1 Silent rs10429586 9 118121096 [A/C] NM_017418 DEC1 Silent rs10982710 9 118121597 [T/C] NM_017418 DEC1 Silent rs4978633 9 118124242 [T/C] NM_017418 DEC1 Silent rs9409144 9 118129621 [T/C] NM_017418 DEC1 Silent rs7018671 9 118131550 [A/C] NM_017418 DEC1 Silent rs7850103 9 118137835 [A/C] NM_017418 DEC1 Silent rs10733614 9 118148224 [T/G] NM_017418 DEC1 Silent rs7859920 9 118148690 [T/C] NM_017418 DEC1 Silent rs10124685 9 118152551 [T/C] NM_017418 DEC1 Silent rs3893062 9 118156112 [T/C] NM_017418 DEC1 Silent rs10982724 9 118157729 [T/C] NM_017418 DEC1 Silent rs10817762 9 118161597 [A/C] NM_017418 DEC1 Silent rs2269700 9 118163563 [T/C] NM_017418 DEC1 EXON Missense_A60V rs7862745 9 118170889 [A/G] rs10124376 9 118173811 [A/G] rs7037974 9 118174830 [T/C] rs721227 9 118179485 [A/C] rs6478163 9 118184602 [A/G] rs10124142 9 118186082 [T/C] rs4979527 9 118189520 [T/G] rs10982742 9 118194134 [A/G] rs10759780 9 118196088 [A/C] rs10982746 9 118199668 [A/G] rs7042718 9 118202187 [T/C] rs7871775 9 118207446 [T/C] rs2157664 9 118209542 [A/G] rs2157663 9 118213502 [T/C] rs1632835 9 118217828 [T/C] rs1632812 9 118223430 [A/G] rs12380029 9 118243754 [A/C] rs12341727 9 118244107 [T/C] rs7852274 9 118248522 [T/C] rs7874499 9 118250623 [T/C] rs6478174 9 118252779 [T/C] rs10817777 9 118255516 [A/G] rs12238100 9 118255620 [T/C] rs7043283 9 118256674 [A/G] rs6478176 9 118258940 [A/G] rs1989767 9 118259578 [T/C] rs12551402 9 118260090 [T/C] rs7038462 9 118261303 [A/G] rs9299225 9 118262641 [A/G] rs9409167 9 118266112 [A/G] rs2418353 9 118276864 [A/G] rs9408872 9 118277315 [A/C] rs10982776 9 118279910 [A/G] rs10124673 9 118286802 [T/C] rs7033617 9 118287508 [A/G] rs2040480 9 118298964 [T/C] rs10119624 9 118305438 [A/G] rs1018845 9 118311164 [A/G] rs10817792 9 118311318 [A/G] rs7046356 9 118311498 [T/G] rs10982793 9 118311709 [T/C] rs10982794 9 118312655 [T/G] rs10982796 9 118313925 [A/G] rs10982797 9 118314095 [T/G] rs4979552 9 118314283 [A/G] rs2900601 9 118314667 [T/C] rs2157666 9 118332688 [T/C] rs7027632 9 118335952 [A/G] rs6478191 9 118339551 [A/C] rs2157668 9 118339739 [T/C] rs10982832 9 118348955 [T/C] rs1981500 9 118352164 [A/G] rs875069 9 118357126 [T/C] rs7859870 9 118367195 [A/G] rs12115665 9 118368761 [A/G] rs10982837 9 118369210 [T/C] rs7860973 9 118376030 [T/C] rs4593632 9 118380578 [A/G] rs10817804 9 118387316 [A/C] rs4979570 9 118392208 [T/C] rs7850229 9 118397913 [A/C] rs10982853 9 118405173 [T/C] rs956325 9 118408803 [A/G] rs10982854 9 118409944 [A/C] rs12378054 9 118411240 [T/C] rs9650715 9 118413485 [A/C] rs1989771 9 118413515 [A/G] rs10982856 9 118415208 [A/G] rs10817809 9 118433442 [T/C] rs2900611 9 118440540 [A/G] rs7031379 9 118445388 [T/C] rs10982873 9 118448142 [T/C] rs10982874 9 118448207 [T/C] rs10817817 9 118451241 [A/G] rs11998893 9 118453513 [T/C] rs7863684 9 118455827 [A/G] rs2188073 9 118456851 [T/C] rs4978647 9 118461146 [T/G] rs7040032 9 118462312 [A/G] rs12380012 9 118475932 [T/C] rs7469580 9 118484694 [T/G] rs10118264 9 118484799 [T/G] rs7045079 9 118485764 [T/C] rs10982901 9 118499474 [A/G] rs2213931 9 118503865 [T/C] NR_109805 LOC101928775 Silent rs10982903 9 118508283 [T/C] rs7855735 9 118512043 [A/G] rs7856085 9 118512297 [A/G] rs7874534 9 118518250 [T/C] rs10429616 9 118518733 [A/G] rs689505 9 118526471 [T/C] rs10982908 9 118526984 [T/C] rs2188078 9 118535406 [A/G] rs2418410 9 118540831 [T/G] rs6478204 9 118540913 [T/C] rs2418412 9 118541068 [T/C] rs7855710 9 118542030 [T/C] rs7043919 9 118550806 [A/G] rs7865455 9 118552995 [T/C] rs2157673 9 118559109 [T/C] rs10982920 9 118559403 [A/G] rs9696301 9 118567019 [A/G] rs10982926 9 118568823 [T/C] rs7850583 9 118570426 [A/G] rs4979583 9 118571428 [T/C] rs7863556 9 118573812 [T/C] rs2106056 9 118585450 [A/G] rs6478207 9 118592791 [A/G] rs10982943 9 118594766 [A/C] rs10817839 9 118597837 [A/G] rs10982946 9 118599720 [T/C] rs966955 9 118607894 [T/G] rs10118806 9 118615701 [T/G] rs10982957 9 118617531 [A/C] rs10982970 9 118624384 [T/G] rs12379210 9 118628595 [A/G] rs2040483 9 118630270 [A/G] rs10759828 9 118634305 [A/G] rs7858008 9 118642639 [T/C] rs995804 9 118644810 [A/G] rs11787606 9 118649073 [A/C] rs1243 9 118650653 [A/C] NR_024032 LINC00474 EXON Silent rs1989775 9 118650689 [A/G] NR_024032 LINC00474 EXON Silent rs2040485 9 118650724 [A/G] NR_024032 LINC00474 EXON Silent rs10982982 9 118651401 [T/C] NR_024032 LINC00474 Silent rs10982987 9 118653960 [A/G] NR_024032 LINC00474 Silent rs10817846 9 118657072 [A/C] NR_024032 LINC00474 Silent rs10982990 9 118658716 [A/G] NR_024032 LINC00474 Silent rs4979591 9 118660341 [T/C] NR_024032 LINC00474 Silent rs10982996 9 118662045 [A/C] NR_024032 LINC00474 Silent rs10982997 9 118662804 [T/C] NR_024032 LINC00474 Silent rs9409176 9 118665465 [A/G] NR_024032 LINC00474 Silent rs9408883 9 118666158 [T/C] NR_024032 LINC00474 Silent rs6478213 9 118677606 [T/C] NR_024032 LINC00474 Silent rs9299235 9 118684791 [A/G] NR_024032 LINC00474 Silent rs12683184 9 118685872 [A/G] NR_024032 LINC00474 Silent rs7046007 9 118692191 [T/C] rs7027312 9 118694535 [A/G] rs6478215 9 118698901 [A/G] rs9409178 9 118699375 [A/G] rs12552970 9 118707467 [A/G] rs7868474 9 118711935 [T/C] rs4979597 9 118712965 [T/C] rs9408887 9 118713227 [A/G] rs2106063 9 118716486 [T/G] rs7468745 9 118719627 [A/G] rs1993013 9 118719754 [T/C] rs12115454 9 118720050 [A/G] rs7468919 9 118720333 [A/G] rs10983034 9 118725422 [A/G] rs10817854 9 118726180 [T/C] rs7468703 9 118726714 [A/G] rs10123549 9 118736263 [T/C] rs4979603 9 118738038 [A/C] rs7469847 9 118738595 [A/G] rs12551620 9 118741214 [A/G] rs1349323 9 118741718 [T/C] rs1901069 9 118744545 [A/C] rs204190 9 118764806 [T/G] rs6478223 9 118781688 [A/G] rs204169 9 118790317 [T/C] rs204168 9 118790936 [A/G] rs1314016 9 118817903 [T/G] rs2418432 9 118841680 [A/G] rs7032067 9 118843677 [T/C] rs2213941 9 118845404 [A/G] rs10739459 9 118869883 [T/C] rs6478230 9 118871741 [A/G] rs204505 9 118887949 [T/C] rs204508 9 118890736 [A/G] rs204514 9 118898718 [A/G] rs10983070 9 118919075 [T/C] NM_002581 PAPPA Silent rs10983073 9 118927725 [T/C] NM_002581 PAPPA Silent rs717963 9 118935491 [A/G] NM_002581 PAPPA Silent rs3789275 9 118945853 [A/G] NM_002581 PAPPA Silent rs445154 9 118949988 [T/C] NM_002581 PAPPA EXON Missense_P324L rs12375498 9 118949998 [T/C] NM_002581 PAPPA EXON Synonymous_C327C rs3789281 9 118953457 [T/G] NM_002581 PAPPA Silent rs1405 9 118954624 [A/G] NM_002581 PAPPA Silent rs446783 9 118957985 [T/G] NM_002581 PAPPA Silent rs3789283 9 118959731 [A/G] NM_002581 PAPPA Silent rs452312 9 118966153 [A/G] NM_002581 PAPPA Silent rs7040545 9 118969339 [A/G] NM_002581 PAPPA Silent rs433687 9 118980520 [T/C] NM_002581 PAPPA Silent rs412644 9 118981886 [T/G] NM_002581 PAPPA Silent rs398293 9 118984002 [A/C] NM_002581 PAPPA Silent rs390623 9 118988913 [A/G] NM_002581 PAPPA Silent rs10983084 9 118998517 [T/C] NM_002581 PAPPA Silent rs961774 9 119007709 [T/C] NM_002581 PAPPA Silent rs10983088 9 119011391 [A/G] NM_002581 PAPPA Silent rs13298102 9 119022802 [T/G] NM_002581 PAPPA Silent rs7847346 9 119023867 [A/C] NM_002581 PAPPA Silent rs17260413 9 119024899 [A/G] NM_002581 PAPPA Silent rs1331140 9 119027718 [A/G] NM_002581 PAPPA Silent rs1999351 9 119031497 [A/G] NM_002581 PAPPA Silent rs4837294 9 119034475 [T/C] NM_002581 PAPPA Silent rs10435873 9 119038034 [T/G] NM_002581 PAPPA Silent rs7874262 9 119041018 [T/C] NM_002581 PAPPA Silent rs4836727 9 119044580 [A/G] NM_002581 PAPPA Silent rs7857793 9 119065358 [T/C] NM_002581 PAPPA Silent rs1924033 9 119068470 [A/G] NM_002581 PAPPA Silent rs11794542 9 119074532 [T/C] NM_002581 PAPPA Silent rs1885984 9 119078249 [T/C] NM_002581 PAPPA Silent rs1885983 9 119078356 [A/G] NM_002581 PAPPA Silent rs1570518 9 119079076 [A/G] NM_002581 PAPPA Silent rs11999361 9 119082586 [T/C] NM_002581 PAPPA Silent rs10817871 9 119085047 [T/C] NM_002581 PAPPA Silent rs4837997 9 119085499 [A/C] NM_002581 PAPPA Silent rs17301196 9 119090744 [T/C] NM_002581 PAPPA Silent rs10435874 9 119092505 [T/C] NM_002581 PAPPA Silent rs2273977 9 119093923 [A/G] NM_002581 PAPPA Silent rs13294988 9 119099873 [T/C] NM_002581 PAPPA Silent rs7862256 9 119103247 [A/G] NM_002581 PAPPA Silent rs7020782 9 119106881 [A/C] NM_002581 PAPPA EXON Missense_S1224Y rs912213 9 119107708 [T/C] NM_002581 PAPPA Silent rs1475215 9 119111270 [T/C] NM_002581 PAPPA Silent rs2224768 9 119112366 [A/G] NM_002581 PAPPA Silent rs10983112 9 119115449 [A/C] NM_002581 PAPPA Silent rs7865534 9 119117464 [T/C] NM_002581 PAPPA Silent rs751543 9 119122342 [T/C] NM_002581 PAPPA Silent rs3747828 9 119125082 [A/G] NM_002581 PAPPA Silent rs7390972 9 119128575 [A/G] NM_002581 PAPPA Silent rs3827668 9 119130030 [A/G] NM_002581 PAPPA EXON Synonymous_V1534V rs12353147 9 119130627 [T/C] NM_002581 PAPPA Silent rs16933460 9 119134443 [A/G] NM_002581 PAPPA Silent rs12339056 9 119136171 [A/G] NM_002581 PAPPA Silent rs9697050 9 119138292 [A/C] NM_002581 PAPPA Silent rs10817881 9 119140488 [A/G] NM_002581 PAPPA Silent rs10983124 9 119142250 [A/C] NM_002581 PAPPA Silent rs4837261 9 119142351 [T/C] NM_002581 PAPPA Silent rs932705 9 119147754 [A/G] NM_002581 PAPPA Silent rs12236532 9 119148669 [A/G] NM_002581 PAPPA Silent rs3789304 9 119150675 [T/C] NM_002581 PAPPA Silent rs16933484 9 119154200 [A/G] NM_002581 PAPPA Silent rs10120005 9 119155568 [A/G] NM_002581 PAPPA Silent rs10983134 9 119159290 [A/G] NM_002581 PAPPA EXON Silent rs3810937 9 119159966 [T/C] NM_002581 PAPPA EXON Silent rs6478235 9 119160150 [T/C] NM_002581 PAPPA EXON Silent rs3810939 9 119160791 [T/C] NM_002581,NR_103711 PAPPA,PAPPA-AS1 EXON Silent,Silent rs3810940 9 119161253 [A/G] NM_002581,NR_103711 PAPPA,PAPPA-AS1 EXON Silent,Silent rs10817885 9 119163067 [T/C] NM_002581 PAPPA EXON Silent rs1054402 9 119163509 [T/C] NM_002581 PAPPA EXON Silent rs16933502 9 119163576 [A/C] NM_002581 PAPPA EXON Silent rs17302884 9 119172047 [A/G] rs10983142 9 119174267 [A/G] rs7860459 9 119175313 [A/C] rs7866443 9 119179876 [A/C] rs4837514 9 119181214 [A/G] rs17303101 9 119181794 [A/G] rs10759837 9 119186551 [T/C] rs9299239 9 119187220 [T/C] rs1507909 9 119187459 [A/G] rs1396042 9 119198324 [T/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs7850952 9 119200847 [A/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs10491580 9 119202365 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs4837530 9 119205302 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs17292484 9 119216196 [A/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs12057009 9 119226730 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs13298648 9 119230710 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs10759842 9 119236373 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs12005639 9 119238756 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs10983187 9 119238935 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs6478238 9 119244942 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs10983190 9 119247845 [T/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs17220352 9 119248059 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs16933586 9 119249361 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs12000812 9 119250281 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs6478241 9 119252629 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs10983194 9 119255010 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs767432 9 119258187 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs4837566 9 119258919 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs1475057 9 119261166 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs4836731 9 119266468 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs4836732 9 119266695 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs4837583 9 119277612 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs4837584 9 119277811 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs4837587 9 119285144 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs12237388 9 119287555 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs12379134 9 119300776 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs7042951 9 119305421 [T/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs10983229 9 119307773 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs7029693 9 119308184 [T/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs10983230 9 119309260 [T/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs10817902 9 119309609 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 EXON Silent,Silent,Silent,Silent,Silent,Silent rs13290997 9 119314217 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs1407243 9 119314851 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs12353296 9 119315629 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs10983234 9 119321931 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs10759848 9 119323187 [A/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NR_033973 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2-AS1 Silent,Silent,Silent,Silent,Silent,Silent rs1547056 9 119326098 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs1467554 9 119331057 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs16933690 9 119339463 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs11787627 9 119341037 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs12376892 9 119348005 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs16933725 9 119350673 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs1885241 9 119355134 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs11791132 9 119356182 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs7866525 9 119357964 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs10983262 9 119367308 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs7855974 9 119367476 [A/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent rs4837682 9 119382930 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NM_001184735 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent,Silent rs10491578 9 119383888 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NM_001184735 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent,Silent rs9697091 9 119397553 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NM_001184735 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent,Silent rs811690 9 119404723 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NM_001184735 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent,Silent rs811458 9 119405271 [T/C] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NM_001184735 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent,Silent rs803892 9 119407546 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NM_001184735 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent,Silent rs7863462 9 119409536 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NM_001184735 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent,Silent rs1742821 9 119419325 [A/G] NM_198186,NM_198187,NM_001184734,NM_014010,NM_198188,NM_001184735 ASTN2,ASTN2,ASTN2,ASTN2,ASTN2,ASTN2 Silent,Silent,Silent,Silent,Silent,Silent rs803939 9 119453455 [T/C] NM_014010,NM_012210,NM_001099679 ASTN2,TRIM32,TRIM32 Silent,Silent,Silent rs803932 9 119458020 [T/C] NM_014010,NM_012210,NM_001099679 ASTN2,TRIM32,TRIM32 Silent,Silent,Silent rs1661300 9 119461275 [A/G] NM_014010,NM_012210,NM_001099679 ASTN2,TRIM32,TRIM32 EXON Silent,Synonymous_V418V,Synonymous_V418V rs3019 9 119462112 [T/C] NM_014010,NM_012210,NM_001099679 ASTN2,TRIM32,TRIM32 EXON Silent,Silent,Silent rs10817923 9 119464644 [T/C] NM_014010 ASTN2 Silent rs803919 9 119466436 [T/C] NM_014010 ASTN2 Silent rs4141711 9 119471881 [T/C] NM_014010 ASTN2 Silent rs12352766 9 119473765 [A/G] NM_014010 ASTN2 Silent rs1441748 9 119474700 [T/C] NM_014010 ASTN2 Silent rs719535 9 119476270 [T/C] NM_014010 ASTN2 Silent rs7870984 9 119482114 [A/G] NM_014010 ASTN2 Silent rs10817926 9 119483436 [A/C] NM_014010 ASTN2 Silent rs1372328 9 119484528 [T/C] NM_014010 ASTN2 Silent rs10983326 9 119487445 [A/C] NM_014010 ASTN2 Silent rs1441747 9 119487811 [A/G] NM_014010 ASTN2 Silent rs9657672 9 119489348 [T/C] NM_014010 ASTN2 Silent rs10125636 9 119489471 [T/C] NM_014010 ASTN2 Silent rs7028544 9 119490572 [A/G] NM_014010 ASTN2 Silent rs1441744 9 119493194 [A/C] NM_014010 ASTN2 Silent rs2274414 9 119495575 [T/G] NM_014010 ASTN2 Silent rs2416570 9 119508795 [A/G] NM_014010 ASTN2 Silent rs894207 9 119510166 [A/G] NM_014010 ASTN2 Silent rs894208 9 119510525 [A/G] NM_014010 ASTN2 Silent rs16933879 9 119512923 [A/G] NM_014010 ASTN2 Silent rs10732384 9 119513452 [A/G] NM_014010 ASTN2 Silent rs961797 9 119516944 [T/C] NM_014010 ASTN2 Silent rs10983338 9 119518570 [A/C] NM_014010 ASTN2 Silent rs1372330 9 119519588 [A/G] NM_014010 ASTN2 Silent rs10983339 9 119522256 [A/G] NM_014010 ASTN2 Silent rs13283406 9 119525648 [T/G] NM_014010 ASTN2 Silent rs930466 9 119525840 [T/C] NM_014010 ASTN2 Silent rs4836849 9 119526375 [T/C] NM_014010 ASTN2 Silent rs12338231 9 119527755 [T/C] NM_014010 ASTN2 Silent rs10759855 9 119528478 [A/C] NM_014010 ASTN2 Silent rs10983343 9 119530849 [A/G] NM_014010 ASTN2 Silent rs7847485 9 119531310 [T/C] NM_014010 ASTN2 Silent rs1441750 9 119533737 [T/C] NM_014010 ASTN2 Silent rs4836850 9 119538249 [A/G] NM_014010 ASTN2 Silent rs7858285 9 119538823 [A/G] NM_014010 ASTN2 Silent rs4837849 9 119539410 [T/C] NM_014010 ASTN2 Silent rs4836851 9 119539531 [A/G] NM_014010 ASTN2 Silent rs4836852 9 119539774 [T/C] NM_014010 ASTN2 Silent rs4837857 9 119542324 [A/C] NM_014010 ASTN2 Silent rs10759859 9 119543476 [A/G] NM_014010 ASTN2 Silent rs7021928 9 119544164 [A/G] NM_014010 ASTN2 Silent rs10817933 9 119544321 [A/G] NM_014010 ASTN2 Silent rs4837864 9 119544433 [T/C] NM_014010 ASTN2 Silent rs10759860 9 119544455 [T/G] NM_014010 ASTN2 Silent rs7030327 9 119546021 [A/C] NM_014010 ASTN2 Silent rs10817934 9 119550051 [T/C] NM_014010 ASTN2 Silent rs7852805 9 119550176 [A/C] NM_014010 ASTN2 Silent rs2028495 9 119554510 [A/G] NM_014010 ASTN2 Silent rs8181035 9 119561084 [A/G] NM_014010 ASTN2 Silent rs36105701 9 119564014 [A/G] NM_014010 ASTN2 Silent rs10983355 9 119566533 [A/C] NM_014010 ASTN2 Silent rs1155556 9 119572334 [T/C] NM_014010 ASTN2 Silent rs7021435 9 119573867 [A/G] NM_014010 ASTN2 Silent rs1556480 9 119575226 [A/G] NM_014010 ASTN2 Silent rs6478254 9 119576473 [A/G] NM_014010 ASTN2 Silent rs7034397 9 119576802 [A/C] NM_014010 ASTN2 Silent rs1156155 9 119578333 [A/G] NM_014010 ASTN2 Silent rs13285974 9 119579217 [A/G] NM_014010 ASTN2 Silent rs4836864 9 119580735 [A/G] NM_014010 ASTN2 Silent rs1547663 9 119582415 [T/C] NM_014010 ASTN2 Silent rs10491575 9 119582571 [T/G] NM_014010 ASTN2 Silent rs3765536 9 119582761 [A/G] NM_014010 ASTN2 Silent rs3765537 9 119582872 [T/G] NM_014010 ASTN2 Silent rs1326807 9 119585852 [T/C] NM_014010 ASTN2 Silent rs1590605 9 119591344 [T/G] NM_014010 ASTN2 Silent rs7866077 9 119598413 [T/C] NM_014010 ASTN2 Silent rs10125438 9 119598710 [A/G] NM_014010 ASTN2 Silent rs943308 9 119599613 [T/C] NM_014010 ASTN2 Silent rs1326814 9 119612028 [T/C] NM_014010 ASTN2 Silent rs2296673 9 119613865 [A/G] NM_014010 ASTN2 Silent rs1536428 9 119616042 [A/G] NM_014010 ASTN2 Silent rs10124883 9 119616074 [A/G] NM_014010 ASTN2 Silent rs10983378 9 119617397 [A/G] NM_014010 ASTN2 Silent rs1359702 9 119618830 [A/G] NM_014010 ASTN2 Silent rs4837952 9 119619937 [A/G] NM_014010 ASTN2 Silent rs10491574 9 119622438 [T/C] NM_014010 ASTN2 Silent rs943306 9 119624675 [T/C] NM_014010 ASTN2 Silent rs2026587 9 119626289 [A/G] NM_014010 ASTN2 Silent rs4837955 9 119626482 [T/C] NM_014010 ASTN2 Silent rs10817944 9 119627005 [A/C] NM_014010 ASTN2 Silent rs7034422 9 119627429 [A/G] NM_014010 ASTN2 Silent rs7862589 9 119627987 [T/C] NM_014010 ASTN2 Silent rs4837957 9 119629567 [A/G] NM_014010 ASTN2 Silent rs9696212 9 119630148 [A/G] NM_014010 ASTN2 Silent rs2225067 9 119633968 [T/C] NM_014010 ASTN2 Silent rs4837967 9 119641176 [A/G] NM_014010 ASTN2 Silent rs7868701 9 119641530 [T/C] NM_014010 ASTN2 Silent rs7868991 9 119641763 [T/C] NM_014010 ASTN2 Silent rs12336175 9 119645481 [A/G] NM_014010 ASTN2 Silent rs1998898 9 119646682 [T/G] NM_014010 ASTN2 Silent rs4837980 9 119649615 [A/G] NM_014010 ASTN2 Silent rs3843825 9 119652622 [T/C] NM_014010 ASTN2 Silent rs12001078 9 119654273 [T/C] NM_014010 ASTN2 Silent rs4091697 9 119654521 [T/C] NM_014010 ASTN2 Silent rs10124561 9 119655679 [A/C] NM_014010 ASTN2 Silent rs4836900 9 119656453 [A/G] NM_014010 ASTN2 Silent rs16934033 9 119657927 [A/G] NM_014010 ASTN2 Silent rs10983398 9 119659517 [A/G] NM_014010 ASTN2 Silent rs10983400 9 119665210 [A/G] NM_014010 ASTN2 Silent rs7042929 9 119666575 [A/C] NM_014010 ASTN2 Silent rs7029188 9 119667151 [T/C] NM_014010 ASTN2 Silent rs4838015 9 119672835 [T/C] NM_014010 ASTN2 Silent rs10817958 9 119673408 [T/C] NM_014010 ASTN2 Silent rs944323 9 119674722 [T/C] NM_014010 ASTN2 Silent rs7029462 9 119676324 [A/G] NM_014010 ASTN2 Silent rs16934052 9 119677365 [A/G] NM_014010 ASTN2 Silent rs2094807 9 119683394 [T/C] NM_014010 ASTN2 Silent rs4838020 9 119685232 [A/G] NM_014010 ASTN2 Silent rs1326804 9 119685435 [A/C] NM_014010 ASTN2 Silent rs16934057 9 119685539 [A/G] NM_014010 ASTN2 Silent rs10513279 9 119685882 [T/C] NM_014010 ASTN2 Silent rs10513280 9 119685920 [T/C] NM_014010 ASTN2 Silent rs1929010 9 119688194 [T/C] NM_014010 ASTN2 Silent rs1929009 9 119688600 [A/G] NM_014010 ASTN2 Silent rs12551186 9 119691640 [T/C] NM_014010 ASTN2 Silent rs16934069 9 119693164 [T/C] NM_014010 ASTN2 Silent rs10983411 9 119693948 [T/C] NM_014010 ASTN2 Silent rs10739477 9 119694420 [A/C] NM_014010 ASTN2 Silent rs10983413 9 119696088 [A/G] NM_014010 ASTN2 Silent rs10759875 9 119696591 [A/C] NM_014010 ASTN2 Silent rs16936575 9 119699452 [T/G] NM_014010 ASTN2 Silent rs2150198 9 119702496 [A/G] NM_014010 ASTN2 Silent rs12345430 9 119706183 [A/G] NM_014010 ASTN2 Silent rs10116120 9 119707772 [T/G] NM_014010 ASTN2 Silent rs10759876 9 119710771 [A/C] NM_014010 ASTN2 Silent rs3849144 9 119712333 [A/C] NM_014010 ASTN2 Silent rs10817967 9 119712401 [A/G] NM_014010 ASTN2 Silent rs2210142 9 119716772 [A/G] NM_014010 ASTN2 Silent rs10983433 9 119719068 [T/C] NM_014010 ASTN2 Silent rs10983434 9 119719162 [T/G] NM_014010 ASTN2 Silent rs10983435 9 119720895 [A/G] NM_014010 ASTN2 Silent rs7026444 9 119720910 [A/G] NM_014010 ASTN2 Silent rs13283397 9 119721232 [T/G] NM_014010 ASTN2 Silent rs16934119 9 119722707 [T/C] NM_014010 ASTN2 Silent rs4838041 9 119724111 [A/C] NM_014010 ASTN2 Silent rs16934138 9 119730256 [A/C] NM_014010 ASTN2 Silent rs10759878 9 119730709 [A/G] NM_014010 ASTN2 Silent rs10759879 9 119732360 [A/G] NM_014010 ASTN2 Silent rs11787916 9 119735989 [A/G] NM_014010 ASTN2 Silent rs2274762 9 119738890 [T/G] NM_014010 ASTN2 Silent rs13284239 9 119745284 [T/C] NM_014010 ASTN2 Silent rs12337139 9 119746836 [A/G] NM_014010 ASTN2 Silent rs7848841 9 119753154 [T/C] NM_014010 ASTN2 Silent rs4144636 9 119762707 [T/G] NM_014010 ASTN2 Silent rs10739480 9 119765231 [A/G] NM_014010 ASTN2 Silent rs7042036 9 119766969 [T/C] NM_014010 ASTN2 Silent rs12686071 9 119767269 [A/G] NM_014010 ASTN2 Silent rs10817972 9 119768572 [A/G] NM_014010 ASTN2 Silent rs3761845 9 119770480 [T/C] NM_014010 ASTN2 EXON Synonymous_P443P rs7036098 9 119770551 [A/G] NM_014010 ASTN2 Silent rs1537528 9 119771893 [A/G] NM_014010 ASTN2 Silent rs10759884 9 119776430 [A/G] NM_014010 ASTN2 Silent rs10739481 9 119777844 [A/C] NM_014010 ASTN2 Silent rs2418446 9 119779810 [T/C] NM_014010 ASTN2 Silent rs10817976 9 119780936 [T/G] NM_014010 ASTN2 Silent rs7874684 9 119783586 [A/G] NM_014010 ASTN2 Silent rs6478272 9 119784443 [A/G] NM_014010 ASTN2 Silent rs10817980 9 119784980 [T/G] NM_014010 ASTN2 Silent rs12341741 9 119785506 [T/C] NM_014010 ASTN2 Silent rs949870 9 119786753 [T/C] NM_014010 ASTN2 Silent rs7047287 9 119789130 [T/C] NM_014010 ASTN2 Silent rs7857238 9 119792047 [T/C] NM_014010 ASTN2 Silent rs7036846 9 119798885 [T/C] NM_014010 ASTN2 Silent rs9697192 9 119799584 [T/C] NM_014010 ASTN2 Silent rs1334078 9 119800808 [T/C] NM_014010 ASTN2 Silent rs1334077 9 119802694 [A/G] NM_014010 ASTN2 Silent rs12351322 9 119803284 [T/G] NM_014010 ASTN2 Silent rs7855056 9 119803528 [A/C] NM_014010 ASTN2 Silent rs10481683 9 119803933 [T/C] NM_014010 ASTN2 Silent rs10983472 9 119806789 [T/C] NM_014010 ASTN2 Silent rs7038712 9 119808106 [T/C] NM_014010 ASTN2 Silent rs10817983 9 119808697 [T/G] NM_014010 ASTN2 Silent rs4836966 9 119808900 [T/C] NM_014010 ASTN2 Silent rs4838117 9 119811790 [T/G] NM_014010 ASTN2 Silent rs13298897 9 119811891 [T/C] NM_014010 ASTN2 Silent rs10817987 9 119812580 [A/C] NM_014010 ASTN2 Silent rs1334070 9 119815778 [A/G] NM_014010 ASTN2 Silent rs10983479 9 119816239 [T/C] NM_014010 ASTN2 Silent rs10119031 9 119816619 [A/G] NM_014010 ASTN2 Silent rs10119137 9 119817024 [A/G] NM_014010 ASTN2 Silent rs944976 9 119817038 [A/G] NM_014010 ASTN2 Silent rs6478276 9 119818979 [A/C] NM_014010 ASTN2 Silent rs6478277 9 119821287 [T/C] NM_014010 ASTN2 Silent rs6478278 9 119821314 [A/G] NM_014010 ASTN2 Silent rs7872915 9 119822186 [T/G] NM_014010 ASTN2 Silent rs4087490 9 119823868 [T/C] NM_014010 ASTN2 Silent rs10983487 9 119824051 [T/C] NM_014010 ASTN2 Silent rs10121565 9 119825237 [A/G] NM_014010 ASTN2 Silent rs11789058 9 119826169 [A/G] NM_014010 ASTN2 Silent rs7848256 9 119826602 [A/G] NM_014010 ASTN2 Silent rs7848547 9 119826990 [T/C] NM_014010 ASTN2 Silent rs7848689 9 119827197 [A/C] NM_014010 ASTN2 Silent rs10983505 9 119835353 [T/C] NM_014010 ASTN2 Silent rs10118188 9 119836771 [T/G] NM_014010 ASTN2 Silent rs12344337 9 119838444 [T/G] NM_014010 ASTN2 Silent rs16934284 9 119839328 [T/C] NM_014010 ASTN2 Silent rs10759896 9 119840344 [T/C] NM_014010 ASTN2 Silent rs1889318 9 119843051 [T/C] NM_014010 ASTN2 Silent rs1105892 9 119843213 [A/C] NM_014010 ASTN2 Silent rs1105890 9 119843385 [T/C] NM_014010 ASTN2 Silent rs1577133 9 119844069 [T/C] NM_014010 ASTN2 Silent rs12339142 9 119854198 [A/G] NM_014010 ASTN2 Silent rs10983516 9 119856725 [T/C] NM_014010 ASTN2 Silent rs11791192 9 119857460 [A/C] NM_014010 ASTN2 Silent rs10983517 9 119858116 [A/G] NM_014010 ASTN2 Silent rs10983521 9 119863851 [A/G] NM_014010 ASTN2 Silent rs7031714 9 119864616 [A/G] NM_014010 ASTN2 Silent rs10983522 9 119865441 [T/C] NM_014010 ASTN2 Silent rs13297784 9 119865765 [T/C] NM_014010 ASTN2 Silent rs16934320 9 119870336 [A/G] NM_014010 ASTN2 Silent rs13285598 9 119872587 [A/G] NM_014010 ASTN2 Silent rs1889320 9 119876954 [T/G] NM_014010 ASTN2 Silent rs11789158 9 119878362 [A/G] NM_014010 ASTN2 Silent rs11789213 9 119878770 [A/C] NM_014010 ASTN2 Silent rs3923774 9 119880993 [T/C] NM_014010 ASTN2 Silent rs10983537 9 119885715 [A/G] NM_014010 ASTN2 Silent rs1572155 9 119887577 [A/G] NM_014010 ASTN2 Silent rs10817997 9 119896151 [A/G] NM_014010 ASTN2 Silent rs1413413 9 119899060 [T/C] NM_014010 ASTN2 Silent rs4090221 9 119901378 [A/G] NM_014010 ASTN2 Silent rs10817999 9 119903506 [T/C] NM_014010 ASTN2 Silent rs13283855 9 119905583 [T/C] NM_014010 ASTN2 Silent rs16934346 9 119908494 [A/G] NM_014010 ASTN2 Silent rs10983551 9 119913608 [T/C] NM_014010 ASTN2 Silent rs2065614 9 119913953 [T/C] NM_014010 ASTN2 Silent rs7848457 9 119914590 [A/G] NM_014010 ASTN2 Silent rs1537526 9 119914943 [A/G] NM_014010 ASTN2 Silent rs7019490 9 119920031 [T/G] NM_014010 ASTN2 Silent rs1334081 9 119921723 [T/C] NM_014010 ASTN2 Silent rs17309941 9 119922519 [A/G] NM_014010 ASTN2 Silent rs1334082 9 119923266 [T/C] NM_014010 ASTN2 Silent rs6478282 9 119925095 [T/G] NM_014010 ASTN2 Silent rs10983556 9 119932558 [A/G] NM_014010 ASTN2 Silent rs1413409 9 119939389 [T/C] NM_014010 ASTN2 Silent rs977937 9 119942649 [T/C] NM_014010 ASTN2 Silent rs10983562 9 119945170 [T/C] NM_014010 ASTN2 Silent rs10983563 9 119946330 [T/C] NM_014010 ASTN2 Silent rs10983564 9 119946647 [A/C] NM_014010 ASTN2 Silent rs6478287 9 119947461 [T/G] NM_014010 ASTN2 Silent rs10983566 9 119948016 [A/G] NM_014010 ASTN2 Silent rs10759906 9 119955982 [A/G] NM_014010 ASTN2 Silent rs7858836 9 119956288 [T/C] NM_014010 ASTN2 Silent rs10818012 9 119957909 [T/C] NM_014010 ASTN2 Silent rs958804 9 119958853 [T/C] NM_014010 ASTN2 Silent rs915281 9 119967963 [T/C] NM_014010 ASTN2 Silent rs6478290 9 119968145 [A/C] NM_014010 ASTN2 Silent rs915282 9 119979614 [A/G] NM_014010 ASTN2 Silent rs2184543 9 119986987 [A/G] NM_014010 ASTN2 Silent rs4838299 9 119989912 [A/G] NM_014010 ASTN2 Silent rs10121207 9 119990164 [T/C] NM_014010 ASTN2 Silent rs10818014 9 119990556 [A/G] NM_014010 ASTN2 Silent rs11787579 9 119992025 [T/C] NM_014010 ASTN2 Silent rs6478297 9 119992795 [T/C] NM_014010 ASTN2 Silent rs1335405 9 119993022 [T/C] NM_014010 ASTN2 Silent rs4838301 9 119993084 [T/C] NM_014010 ASTN2 Silent rs1160246 9 119993094 [T/C] NM_014010 ASTN2 Silent rs6478298 9 119994691 [T/C] NM_014010 ASTN2 Silent rs10513289 9 120000826 [T/C] NM_014010 ASTN2 Silent rs16934422 9 120001836 [T/C] NM_014010 ASTN2 Silent rs10465132 9 120007625 [T/C] NM_014010 ASTN2 Silent rs10818015 9 120011056 [A/C] NM_014010 ASTN2 Silent rs4838347 9 120011533 [T/C] NM_014010 ASTN2 Silent rs1335419 9 120012421 [A/G] NM_014010 ASTN2 Silent rs1335416 9 120014256 [A/G] NM_014010 ASTN2 Silent rs10983584 9 120017634 [T/C] NM_014010 ASTN2 Silent rs11794931 9 120023135 [A/G] NM_014010 ASTN2 Silent rs10983589 9 120023774 [T/C] NM_014010 ASTN2 Silent rs3900788 9 120028948 [T/C] NM_014010 ASTN2 Silent rs1007834 9 120029861 [T/C] NM_014010 ASTN2 Silent rs7043216 9 120031254 [A/G] NM_014010 ASTN2 Silent rs9969676 9 120032299 [T/C] NM_014010 ASTN2 Silent rs7019790 9 120032451 [A/G] NM_014010 ASTN2 Silent rs6478300 9 120035769 [A/C] NM_014010 ASTN2 Silent rs1889655 9 120038801 [T/C] NM_014010 ASTN2 Silent rs10513297 9 120050463 [T/C] NM_014010 ASTN2 Silent rs7026867 9 120052359 [A/C] NM_014010 ASTN2 Silent rs10759913 9 120052529 [T/C] NM_014010 ASTN2 Silent rs2297697 9 120053695 [A/G] NM_014010 ASTN2 EXON Synonymous_S180S rs7862566 9 120054021 [T/C] NM_014010 ASTN2 Silent rs3893339 9 120055202 [A/C] NM_014010 ASTN2 Silent rs16934465 9 120058855 [T/C] NM_014010 ASTN2 Silent rs10983613 9 120065787 [T/C] NM_014010 ASTN2 Silent rs7022764 9 120068520 [A/G] NM_014010 ASTN2 Silent rs1572306 9 120071548 [A/G] NM_014010 ASTN2 Silent rs1572307 9 120071949 [A/G] NM_014010 ASTN2 Silent rs11790950 9 120078941 [T/G] NM_014010 ASTN2 Silent rs12342325 9 120081700 [A/G] NM_014010 ASTN2 Silent rs7021801 9 120085704 [A/C] NM_014010 ASTN2 Silent rs10983619 9 120086176 [A/C] NM_014010 ASTN2 Silent rs10983624 9 120095530 [T/C] NM_014010 ASTN2 Silent rs1339921 9 120099047 [T/C] NM_014010 ASTN2 Silent rs3924642 9 120099585 [T/C] NM_014010 ASTN2 Silent rs10983627 9 120102138 [T/C] NM_014010 ASTN2 Silent rs1934485 9 120107961 [A/G] NM_014010 ASTN2 Silent rs10818024 9 120108044 [T/C] NM_014010 ASTN2 Silent rs1934484 9 120108170 [A/C] NM_014010 ASTN2 Silent rs4240415 9 120109509 [T/C] NM_014010 ASTN2 Silent rs12552082 9 120110190 [A/G] NM_014010 ASTN2 Silent rs10818029 9 120114228 [T/C] NM_014010 ASTN2 Silent rs7029526 9 120122802 [A/G] NM_014010 ASTN2 Silent rs10818030 9 120126470 [A/G] NM_014010 ASTN2 Silent rs10513300 9 120130206 [T/C] NM_014010 ASTN2 Silent rs1416940 9 120133394 [T/G] NM_014010 ASTN2 Silent rs1339929 9 120137252 [T/C] NM_014010 ASTN2 Silent rs2226006 9 120137758 [T/C] NM_014010 ASTN2 Silent rs1339930 9 120141746 [A/G] NM_014010 ASTN2 Silent rs1934487 9 120141805 [A/G] NM_014010 ASTN2 Silent rs10818033 9 120145848 [A/G] NM_014010 ASTN2 Silent rs16905575 9 120146772 [T/G] NM_014010 ASTN2 Silent rs7042295 9 120148425 [A/G] NM_014010 ASTN2 Silent rs10435877 9 120149257 [T/C] NM_014010 ASTN2 Silent rs1416943 9 120150050 [A/G] NM_014010 ASTN2 Silent rs4419882 9 120151034 [T/C] NM_014010 ASTN2 Silent rs12551446 9 120153306 [A/C] NM_014010 ASTN2 Silent rs4837163 9 120154325 [T/C] NM_014010 ASTN2 Silent rs1416942 9 120154849 [T/G] NM_014010 ASTN2 Silent rs10983645 9 120160678 [A/G] NM_014010 ASTN2 Silent rs10513301 9 120161777 [T/C] NM_014010 ASTN2 Silent rs7872945 9 120162325 [T/C] NM_014010 ASTN2 Silent rs7875944 9 120162380 [T/C] NM_014010 ASTN2 Silent rs4240422 9 120163466 [T/C] NM_014010 ASTN2 Silent rs1934483 9 120165049 [T/G] NM_014010 ASTN2 Silent rs7467917 9 120165611 [T/C] NM_014010 ASTN2 Silent rs10739493 9 120169552 [T/C] NM_014010 ASTN2 Silent rs7023773 9 120179586 [A/C] rs955302 9 120185992 [A/G] rs4836590 9 120189474 [T/G] rs17419570 9 120192435 [T/G] rs4146493 9 120194838 [A/G] rs17419694 9 120196215 [T/G] rs10983653 9 120197413 [T/C] rs16905625 9 120199140 [T/C] rs1547926 9 120203604 [A/G] rs12685568 9 120209679 [A/C] rs9987535 9 120210027 [A/G] rs10513307 9 120210307 [T/C] rs10983659 9 120211956 [A/G] rs10818038 9 120212123 [T/C] rs1890047 9 120214676 [A/G] rs4837254 9 120216660 [T/C] rs1572523 9 120217280 [A/G] rs13285674 9 120225010 [A/G] rs7025237 9 120225715 [T/G] rs1577808 9 120226415 [T/G] rs10983664 9 120229555 [A/G] rs12115318 9 120239806 [A/G] rs10983670 9 120240163 [A/G] rs1337206 9 120248751 [T/C] rs10983672 9 120249201 [T/C] rs4633129 9 120249360 [T/C] rs10983673 9 120249464 [T/C] rs1316439 9 120250392 [T/C] rs1337215 9 120254911 [A/G] rs2786130 9 120255966 [T/C] rs12348211 9 120263905 [T/G] rs540657 9 120270109 [T/C] rs11794261 9 120275146 [A/G] rs12337381 9 120275159 [T/C] rs549493 9 120277096 [T/C] rs545966 9 120277454 [A/C] rs4510935 9 120285351 [T/C] rs1985317 9 120292334 [T/C] rs10983688 9 120293454 [T/C] rs495062 9 120299808 [T/C] rs12335556 9 120302113 [T/G] rs559135 9 120302842 [T/C] rs11795161 9 120303051 [T/G] rs10117151 9 120304076 [A/C] rs540178 9 120309723 [T/C] rs12339717 9 120315637 [T/C] rs495083 9 120316896 [A/G] rs476999 9 120327559 [A/C] rs565055 9 120339304 [A/C] rs7858743 9 120341514 [A/G] rs1252006 9 120352817 [T/C] rs7857205 9 120353505 [A/G] rs7857333 9 120353610 [A/G] rs10983707 9 120358616 [A/C] rs10983708 9 120360094 [A/C] rs10983712 9 120368736 [T/C] rs7875849 9 120369028 [A/G] rs1329055 9 120372882 [T/C] rs10491854 9 120374480 [T/G] rs10983716 9 120376134 [A/C] rs1928295 9 120378483 [T/C] rs1155928 9 120389465 [T/C] rs1887904 9 120390282 [A/C] rs2026726 9 120396978 [T/C] rs7026557 9 120398385 [A/C] rs4837462 9 120410219 [T/G] rs7034845 9 120413192 [A/G] NR_109806 LOC101928797 EXON Silent rs10983736 9 120416248 [A/C] NR_109806 LOC101928797 Silent rs10983737 9 120416402 [A/G] NR_109806 LOC101928797 Silent rs913615 9 120418118 [A/C] NR_109806 LOC101928797 Silent rs1854448 9 120427484 [A/G] rs7039756 9 120431545 [A/C] rs10818066 9 120433401 [T/C] rs1329057 9 120441946 [T/C] rs960312 9 120443779 [A/G] rs16906007 9 120447398 [A/G] rs1252038 9 120448498 [T/G] rs1360094 9 120449466 [A/G] rs4837496 9 120450798 [A/G] rs10759930 9 120461621 [T/C] rs2737191 9 120462715 [A/G] rs1927912 9 120469426 [T/C] NM_003266,NM_138557,NM_138554 TLR4,TLR4,TLR4 Silent,Silent,Silent rs11536869 9 120469832 [A/G] NM_003266,NM_138557,NM_138554 TLR4,TLR4,TLR4 Silent,Silent,Silent rs1927911 9 120470054 [A/G] NM_003266,NM_138557,NM_138554 TLR4,TLR4,TLR4 Silent,Silent,Silent rs11536877 9 120471358 [A/G] NM_003266,NM_138557,NM_138554 TLR4,TLR4,TLR4 Silent,Silent,Silent rs5030717 9 120473834 [A/G] NM_003266,NM_138557,NM_138554 TLR4,TLR4,TLR4 Silent,Silent,Silent rs2149356 9 120474199 [T/G] NM_003266,NM_138557,NM_138554 TLR4,TLR4,TLR4 Silent,Silent,Silent rs4986791 9 120475602 [T/C] NM_003266,NM_138557,NM_138554 TLR4,TLR4,TLR4 EXON Missense_T359I,Missense_T199I,Missense_T399I rs4987233 9 120475605 [A/G] NM_003266,NM_138557,NM_138554 TLR4,TLR4,TLR4 EXON Missense_S360N,Missense_S200N,Missense_S400N rs11536897 9 120480010 [A/G] rs1927906 9 120480115 [T/C] rs1554973 9 120480812 [T/C] rs7856729 9 120481856 [T/G] rs7846989 9 120482940 [T/C] rs7037225 9 120483639 [T/C] rs913930 9 120484009 [A/G] rs2183016 9 120485215 [A/C] rs7045953 9 120485795 [A/G] rs7025144 9 120496387 [T/C] rs10465133 9 120497958 [T/G] rs7866830 9 120502265 [A/G] rs7870814 9 120503274 [A/G] rs10818081 9 120510364 [A/C] rs17330490 9 120510899 [A/G] rs756136 9 120512266 [T/C] rs10818085 9 120514271 [T/C] rs10739501 9 120514683 [T/C] rs2225207 9 120514770 [T/C] rs10123941 9 120518162 [T/C] rs10818087 9 120518859 [A/G] rs1927896 9 120519878 [A/G] rs7026522 9 120520277 [T/C] rs10759943 9 120522873 [A/G] rs7027603 9 120524162 [A/G] rs7027711 9 120524178 [T/G] rs10983778 9 120526112 [A/G] rs1475546 9 120533422 [T/C] rs10739502 9 120536514 [T/G] rs1927934 9 120540290 [T/C] rs7018934 9 120543270 [T/C] rs7046116 9 120546133 [A/C] rs12352822 9 120547282 [A/G] rs4836703 9 120548934 [A/G] rs2225208 9 120556606 [T/C] rs11999865 9 120559214 [T/G] rs1927925 9 120559603 [T/C] rs2149361 9 120560559 [T/C] rs7852394 9 120571251 [A/C] rs2149358 9 120571308 [A/G] rs12342517 9 120576387 [T/G] rs10759948 9 120576634 [T/C] rs4837510 9 120591239 [A/G] rs10983810 9 120593209 [T/G] rs10739508 9 120596211 [T/C] rs17333569 9 120606298 [A/G] rs1514762 9 120606871 [A/G] rs10513311 9 120608720 [A/C] rs12339926 9 120611961 [A/G] rs694428 9 120613258 [A/G] rs1709578 9 120613902 [T/G] rs524074 9 120616052 [A/C] rs6478330 9 120619093 [T/C] rs12555480 9 120624627 [T/C] rs10818096 9 120626011 [T/C] rs10818097 9 120626599 [T/C] rs963466 9 120629491 [A/G] rs11790155 9 120630599 [T/C] rs2296943 9 120632054 [A/G] rs908198 9 120636801 [T/C] rs2048741 9 120637262 [A/G] rs4458937 9 120640228 [A/G] rs10818102 9 120659844 [T/C] rs1399428 9 120660568 [T/C] rs10435879 9 120665221 [T/G] rs12683891 9 120666366 [T/C] rs7872095 9 120669106 [T/C] rs1399436 9 120669183 [A/G] rs4836705 9 120670834 [A/C] rs7043830 9 120678965 [T/C] rs10513316 9 120682548 [T/C] rs7034923 9 120683944 [T/C] rs12350773 9 120688340 [A/G] rs520466 9 120693160 [T/C] rs1514775 9 120695091 [A/G] rs7045604 9 120695362 [T/C] rs1996215 9 120704358 [T/G] rs626584 9 120713296 [T/G] rs7028883 9 120717586 [A/G] rs10115978 9 120728632 [T/C] rs2722824 9 120732125 [A/C] rs1930713 9 120733712 [A/G] rs2809398 9 120737136 [T/C] rs2416603 9 120737349 [A/G] rs955117 9 120739065 [A/G] rs2225600 9 120745836 [A/C] rs9408905 9 120751155 [A/G] rs17345248 9 120756290 [T/C] rs2245960 9 120757370 [T/C] rs1930697 9 120763748 [T/C] rs2806085 9 120767777 [A/G] rs2780246 9 120769844 [T/C] rs2806081 9 120773585 [T/C] rs2722841 9 120786036 [T/C] rs2809420 9 120787025 [T/C] rs2416604 9 120795990 [T/C] rs2809369 9 120814952 [T/C] rs17431621 9 120822099 [A/G] rs2900142 9 120831882 [T/C] rs7039379 9 120833115 [T/C] rs2722866 9 120839644 [T/C] rs2722865 9 120841269 [T/C] rs2252957 9 120842790 [A/G] rs2809380 9 120851579 [T/C] rs16906696 9 120854437 [A/G] rs2722806 9 120854939 [T/C] rs2722814 9 120862912 [T/C] rs12349683 9 120863737 [T/C] rs2806110 9 120869313 [T/C] rs13299605 9 120874982 [T/C] rs721737 9 120883836 [T/C] rs2769164 9 120889966 [A/G] rs2769183 9 120899084 [A/G] rs11999006 9 120902394 [A/C] rs955259 9 120904985 [T/C] rs2806116 9 120909742 [A/G] rs2806117 9 120913104 [T/C] rs2025881 9 120916741 [A/C] rs16906779 9 120919811 [A/G] rs10983899 9 120922128 [T/C] rs10818118 9 120925960 [T/C] rs2769186 9 120929609 [A/G] rs2769192 9 120945445 [A/G] rs913367 9 120953087 [A/G] rs12552190 9 120962237 [T/G] rs12551731 9 120962282 [A/G] rs1327797 9 120967585 [T/G] rs10818121 9 120969775 [A/G] rs1327798 9 120970254 [A/G] rs10983917 9 120975586 [A/G] rs10513326 9 120978387 [A/C] rs10983918 9 120978904 [A/G] rs1571272 9 120981380 [A/G] rs10983923 9 120985358 [A/C] rs927953 9 120988194 [T/C] rs1410201 9 120992769 [A/G] rs10123927 9 120994586 [T/C] rs16906813 9 121000642 [A/G] rs10983934 9 121006917 [T/C] rs10983936 9 121008432 [A/C] rs10983944 9 121010969 [T/C] rs4836716 9 121010987 [A/G] rs10983945 9 121016602 [T/C] rs10983950 9 121036075 [A/G] rs1927320 9 121037997 [T/G] rs954070 9 121041753 [T/C] rs12236645 9 121045042 [T/C] rs1342504 9 121045603 [T/G] rs10759964 9 121051077 [A/G] rs7875170 9 121062057 [T/C] rs1927321 9 121066417 [A/C] rs10983957 9 121069222 [T/C] rs7874874 9 121071032 [A/C] rs7025261 9 121072539 [A/G] rs10513328 9 121074020 [A/C] rs7862653 9 121075273 [A/G] rs12552250 9 121076460 [A/G] rs7873210 9 121080374 [A/G] rs12345715 9 121080656 [T/G] rs17364704 9 121081100 [A/C] rs7047454 9 121081314 [T/C] rs1418495 9 121090791 [T/C] rs7866799 9 121094973 [T/C] rs10983993 9 121110670 [T/G] rs7036676 9 121111790 [T/C] rs10124472 9 121125496 [A/C] rs3893408 9 121127354 [T/C] rs10983999 9 121133696 [T/C] rs7864888 9 121136695 [T/C] rs17366047 9 121137235 [A/G] rs4593622 9 121139437 [A/G] rs10513331 9 121140638 [T/C] rs7855921 9 121149060 [A/G] rs12350323 9 121151094 [T/C] rs1342500 9 121157043 [T/C] rs1418514 9 121158641 [T/C] rs12350098 9 121159542 [A/G] rs10818145 9 121162755 [A/C] rs16907082 9 121163842 [T/C] rs7866951 9 121164248 [A/G] rs10818147 9 121168521 [A/G] rs4836723 9 121171878 [T/C] rs1935624 9 121173877 [A/G] rs1935621 9 121177842 [A/G] rs4401938 9 121179496 [T/C] rs10818151 9 121182554 [T/C] rs10984022 9 121183669 [A/C] rs17367380 9 121190095 [T/C] rs10818153 9 121191140 [A/G] rs10435881 9 121195316 [A/G] rs1891442 9 121201702 [A/G] rs7022505 9 121213149 [T/C] rs1418501 9 121218719 [T/C] rs7030074 9 121241085 [T/C] rs7022160 9 121243073 [A/G] rs7858444 9 121244869 [T/C] rs10818161 9 121253842 [T/C] rs12342183 9 121254222 [A/G] rs10984054 9 121263967 [T/C] rs7029465 9 121277542 [A/G] rs7864314 9 121282616 [T/C] rs10984077 9 121284915 [A/G] rs10984078 9 121288997 [T/C] rs10818184 9 121301720 [A/G] rs12378763 9 121312200 [A/G] rs7848936 9 121312632 [A/G] rs7848982 9 121312824 [T/C] rs7857107 9 121314808 [A/G] rs17448174 9 121315863 [A/G] rs9409210 9 121317025 [T/C] rs10116305 9 121318471 [A/G] rs1360810 9 121320294 [T/C] rs7036491 9 121321501 [A/G] rs11792957 9 121323568 [T/C] rs10818187 9 121325521 [A/G] rs7855145 9 121326409 [A/G] rs1335258 9 121327323 [A/C] rs7469341 9 121327603 [A/C] rs10759982 9 121328526 [T/C] rs10984091 9 121334810 [T/C] rs11790829 9 121342907 [A/G] rs1335255 9 121344767 [T/G] rs7864368 9 121351852 [A/G] rs7037161 9 121351909 [A/G] rs1414097 9 121359692 [T/C] rs10759986 9 121363428 [A/C] rs10984116 9 121364552 [A/G] rs10124018 9 121369402 [T/C] rs1335246 9 121370958 [A/G] rs2416662 9 121372582 [T/C] rs16907415 9 121375928 [A/G] rs4301511 9 121385397 [A/C] rs7850923 9 121387146 [T/C] rs10818206 9 121406364 [A/C] rs4837567 9 121406435 [T/C] rs1508377 9 121406910 [A/G] rs1508378 9 121407046 [A/G] rs10118699 9 121409332 [A/G] rs4837570 9 121417973 [T/G] rs10759994 9 121418763 [A/G] rs1335259 9 121424346 [A/G] rs10984153 9 121427985 [A/G] rs1414096 9 121428389 [A/G] rs7849371 9 121430880 [A/G] rs10759998 9 121442207 [A/G] NR_151725 LINC02578 Silent rs2416680 9 121450688 [T/C] NR_151725 LINC02578 Silent rs10984174 9 121452706 [A/G] NR_151725 LINC02578 Silent rs10116611 9 121452775 [A/G] NR_151725 LINC02578 Silent rs4836729 9 121456562 [T/C] NR_151725 LINC02578 Silent rs10818219 9 121458762 [A/G] NR_151725 LINC02578 Silent rs13288491 9 121463210 [T/C] NR_151725 LINC02578 Silent rs1355034 9 121463496 [A/C] NR_151725 LINC02578 Silent rs10984181 9 121464718 [T/G] NR_151725 LINC02578 Silent rs577362 9 121466476 [T/C] NR_151725 LINC02578 Silent rs10513341 9 121467481 [T/C] NR_151725 LINC02578 Silent rs10984184 9 121467568 [A/G] NR_151725 LINC02578 Silent rs3750471 9 121468101 [T/C] NR_151725 LINC02578 Silent rs3750473 9 121468282 [T/G] NR_151725 LINC02578 Silent rs16907545 9 121469510 [A/G] NR_151725 LINC02578 Silent rs10984189 9 121475729 [A/C] NR_151725 LINC02578 Silent rs12235164 9 121481298 [T/C] NR_151725 LINC02578 Silent rs10513342 9 121482333 [A/G] NR_151725 LINC02578 Silent rs10818225 9 121482477 [T/C] NR_151725 LINC02578 Silent rs1508389 9 121494898 [A/C] NR_151725 LINC02578 Silent rs965853 9 121501251 [A/G] NR_151725 LINC02578 Silent rs4433214 9 121502691 [A/G] NR_151725 LINC02578 Silent rs7868904 9 121506034 [A/G] NR_151725 LINC02578 Silent rs7021488 9 121510009 [T/C] rs9632909 9 121522885 [T/C] rs10984217 9 121524247 [A/G] rs7029069 9 121524285 [T/C] rs2136062 9 121525411 [T/G] rs2416686 9 121529204 [T/C] rs12003016 9 121529812 [T/C] rs2025756 9 121535396 [T/C] rs1326628 9 121536509 [T/G] rs10984224 9 121539063 [T/C] rs2900156 9 121545222 [A/G] rs1326624 9 121545457 [A/G] rs1571091 9 121546954 [T/G] rs1326635 9 121552358 [T/C] rs10984229 9 121559353 [T/C] rs1409550 9 121559990 [T/G] rs12236072 9 121560983 [A/G] rs7025578 9 121577481 [T/G] rs10984245 9 121588193 [T/C] rs10818242 9 121593535 [A/G] rs961699 9 121597472 [T/C] rs1359679 9 121597614 [T/C] rs10818249 9 121624958 [T/C] rs12005473 9 121632541 [A/G] rs1326631 9 121641891 [A/C] rs7853689 9 121645267 [T/C] rs4837588 9 121667815 [A/G] rs10984298 9 121670536 [A/G] rs12237612 9 121698714 [T/C] rs10984333 9 121711420 [T/G] rs10984339 9 121719114 [T/C] rs12376255 9 121724665 [T/C] rs2818326 9 121724759 [T/C] rs10818262 9 121727404 [A/G] rs2807724 9 121729794 [A/G] rs7048230 9 121731238 [A/G] rs2818311 9 121738737 [T/C] rs2807714 9 121751926 [T/C] rs2807715 9 121753075 [A/G] rs2818299 9 121753744 [A/G] rs7850538 9 121756868 [A/G] rs2818294 9 121759567 [T/C] rs2818325 9 121765918 [A/G] rs10739528 9 121774806 [A/G] rs2416691 9 121778640 [A/C] rs4836741 9 121782996 [A/G] rs10117035 9 121796354 [T/C] rs7860504 9 121797698 [A/G] rs2109619 9 121798140 [A/C] rs2191622 9 121803609 [T/C] rs10760015 9 121805021 [A/G] rs10122991 9 121808496 [A/G] rs1158809 9 121809618 [T/C] rs6478394 9 121836674 [A/G] rs10984399 9 121836984 [A/G] rs10760018 9 121837820 [A/C] rs10514837 9 121839928 [T/C] rs737640 9 121840391 [A/G] rs7867690 9 121842266 [A/G] rs7018768 9 121844326 [T/C] rs17292757 9 121858094 [T/G] rs2159639 9 121861960 [A/G] rs4836745 9 121862016 [T/C] rs10984412 9 121874856 [T/C] rs10760019 9 121878377 [T/C] rs10984414 9 121881005 [A/G] rs115795 9 121883165 [A/G] rs17292799 9 121911162 [A/G] rs230123 9 121911404 [T/C] rs57440 9 121914488 [T/C] rs10984425 9 121916627 [A/G] rs110797 9 121918081 [A/G] rs10984426 9 121927511 [A/G] rs1571904 9 121927666 [A/G] rs28453 9 121929575 [T/C] NM_014618 BRINP1 EXON Synonymous_S691S rs1043379 9 121930307 [A/G] NM_014618 BRINP1 EXON Synonymous_C447C rs10984430 9 121939671 [A/G] NM_014618 BRINP1 Silent rs230080 9 121951619 [A/G] NM_014618 BRINP1 Silent rs230089 9 121956076 [A/G] NM_014618 BRINP1 Silent rs7018536 9 121961896 [A/G] NM_014618 BRINP1 Silent rs10984435 9 121965240 [A/G] NM_014618 BRINP1 Silent rs1332452 9 121967454 [A/G] NM_014618 BRINP1 Silent rs1332453 9 121967597 [A/C] NM_014618 BRINP1 Silent rs10760025 9 121967957 [A/G] NM_014618 BRINP1 Silent rs1332455 9 121970419 [T/C] NM_014618 BRINP1 Silent rs17476783 9 121971069 [T/C] NM_014618 BRINP1 EXON Missense_R358H rs9696959 9 121973842 [A/G] NM_014618 BRINP1 Silent rs2183964 9 121974448 [A/G] NM_014618 BRINP1 Silent rs7853697 9 121976044 [A/G] NM_014618 BRINP1 Silent rs10984443 9 121979181 [T/G] NM_014618 BRINP1 Silent rs875166 9 121982370 [A/G] NM_014618 BRINP1 Silent rs10984447 9 121984553 [A/G] NM_014618 BRINP1 Silent rs10760028 9 121984673 [T/C] NM_014618 BRINP1 Silent rs10818288 9 121988899 [T/G] NM_014618 BRINP1 Silent rs990028 9 121992549 [T/C] NM_014618 BRINP1 Silent rs990029 9 121992686 [A/G] NM_014618 BRINP1 Silent rs10818289 9 121993508 [T/C] NM_014618 BRINP1 Silent rs989094 9 121996466 [T/C] NM_014618 BRINP1 Silent rs2274157 9 122001000 [A/G] NM_014618 BRINP1 EXON Synonymous_S206S rs12378647 9 122001714 [A/G] NM_014618 BRINP1 Silent rs1571903 9 122008060 [A/G] NM_014618 BRINP1 Silent rs7027123 9 122012643 [T/C] NM_014618 BRINP1 Silent rs539054 9 122014027 [T/C] NM_014618 BRINP1 Silent rs1576836 9 122016593 [A/G] NM_014618 BRINP1 Silent rs12238422 9 122016656 [T/C] NM_014618 BRINP1 Silent rs2031380 9 122023574 [T/C] NM_014618 BRINP1 Silent rs1221136 9 122030076 [T/C] NM_014618 BRINP1 Silent rs10760030 9 122030983 [A/G] NM_014618 BRINP1 Silent rs10818292 9 122035992 [A/G] NM_014618 BRINP1 Silent rs487240 9 122036135 [A/G] NM_014618 BRINP1 Silent rs914651 9 122036993 [T/C] NM_014618 BRINP1 Silent rs680003 9 122039576 [A/G] NM_014618 BRINP1 Silent rs7856245 9 122039704 [A/G] NM_014618 BRINP1 Silent rs7028813 9 122039773 [T/G] NM_014618 BRINP1 Silent rs792933 9 122043820 [A/G] NM_014618 BRINP1 Silent rs10217394 9 122044643 [T/C] NM_014618 BRINP1 Silent rs560056 9 122047381 [A/G] NM_014618 BRINP1 Silent rs4837628 9 122059709 [T/C] NM_014618 BRINP1 Silent rs12683279 9 122060357 [T/C] NM_014618 BRINP1 Silent rs16908223 9 122068881 [T/C] NM_014618 BRINP1 Silent rs10818297 9 122070829 [T/C] NM_014618 BRINP1 Silent rs10739534 9 122071105 [A/G] NM_014618 BRINP1 Silent rs10118663 9 122081818 [A/G] NM_014618 BRINP1 Silent rs17634284 9 122091015 [A/G] NM_014618 BRINP1 Silent rs10984490 9 122095833 [T/C] NM_014618 BRINP1 Silent rs10984491 9 122096532 [A/C] NM_014618 BRINP1 Silent rs10984492 9 122098205 [T/C] NM_014618 BRINP1 Silent rs16908302 9 122112563 [T/C] NM_014618 BRINP1 Silent rs1324623 9 122120197 [T/G] NM_014618 BRINP1 Silent rs4540472 9 122120555 [A/C] NM_014618 BRINP1 Silent rs1324627 9 122132184 [T/G] rs7020462 9 122133105 [T/G] rs10984512 9 122138602 [A/G] rs2025501 9 122140786 [A/G] rs2210379 9 122146403 [T/C] rs1331616 9 122147661 [T/C] rs17635433 9 122149204 [T/C] rs10125966 9 122149592 [T/C] rs7848896 9 122150396 [A/G] rs4455935 9 122154649 [T/C] rs17635586 9 122156770 [T/C] rs10116078 9 122157616 [T/C] rs2150753 9 122158444 [A/G] rs2183761 9 122158693 [A/G] rs7847786 9 122162502 [T/G] rs17635892 9 122166761 [A/C] rs10984519 9 122171470 [T/C] rs1331621 9 122174362 [T/C] rs10491527 9 122176793 [A/G] rs9299259 9 122189165 [A/G] rs10491526 9 122193951 [A/G] rs10818313 9 122198190 [T/C] rs11792112 9 122198457 [T/C] rs10120508 9 122202000 [A/G] rs1331624 9 122204804 [A/C] rs10818318 9 122215618 [A/G] rs16908409 9 122222718 [A/C] rs9299260 9 122222874 [T/C] rs9299261 9 122222907 [A/C] rs1331591 9 122226426 [T/C] rs10818319 9 122233951 [T/G] rs1990422 9 122244046 [A/G] rs7868280 9 122247156 [T/C] rs10984556 9 122247734 [T/G] rs1412055 9 122249965 [A/G] rs12555385 9 122254248 [T/C] rs10491524 9 122257254 [T/C] rs10984560 9 122257627 [T/C] rs10984564 9 122259593 [T/C] rs10984568 9 122260749 [A/G] rs1412056 9 122260800 [A/G] rs11790549 9 122261157 [T/C] rs2416707 9 122261319 [T/C] rs758875 9 122263352 [A/G] rs10491522 9 122264713 [A/G] rs17638213 9 122272453 [T/C] rs10217489 9 122273853 [T/C] rs12345648 9 122277651 [T/C] rs10818328 9 122279421 [T/G] rs12346612 9 122283825 [T/C] rs7849695 9 122288239 [T/C] rs1014162 9 122288413 [A/G] rs10760049 9 122288939 [T/C] rs1009470 9 122289187 [T/G] rs1331606 9 122292292 [A/G] rs1015779 9 122294227 [A/G] rs1331608 9 122300146 [T/C] rs2109664 9 122301156 [T/C] rs1331609 9 122301551 [T/C] rs4644327 9 122303614 [A/G] rs1412061 9 122308536 [A/G] rs9644909 9 122312068 [A/G] rs7854143 9 122313623 [T/C] rs990622 9 122319889 [A/G] rs10818334 9 122333861 [A/C] rs12350353 9 122337372 [T/C] rs12350573 9 122337936 [T/C] rs4412427 9 122341917 [T/C] rs10984605 9 122343811 [A/C] rs10818336 9 122352612 [A/G] rs10122567 9 122355590 [A/G] rs12349509 9 122360136 [T/C] rs10117868 9 122362278 [A/G] rs7021853 9 122372872 [T/G] rs11794047 9 122375077 [A/G] rs17580421 9 122380174 [T/C] rs10120069 9 122390205 [T/C] rs10984619 9 122393306 [A/G] rs17580614 9 122394119 [A/G] rs11788273 9 122408868 [A/C] rs6478430 9 122417221 [A/G] rs12346927 9 122421460 [A/G] rs1860665 9 122422035 [A/C] rs1013282 9 122426409 [T/C] rs10818361 9 122431172 [T/C] rs4837656 9 122434053 [T/C] rs10125439 9 122436623 [T/C] rs10984635 9 122439147 [A/G] rs17648616 9 122439531 [A/G] rs6415829 9 122442505 [A/G] rs4466463 9 122446737 [T/C] rs12551982 9 122451259 [A/G] rs12376944 9 122456873 [T/C] rs4437722 9 122463062 [T/C] rs10984654 9 122473586 [T/C] rs4407966 9 122474896 [A/G] rs7042510 9 122477415 [T/C] rs4520239 9 122479120 [A/G] rs4642724 9 122481907 [T/G] rs10818370 9 122485503 [T/C] rs12343952 9 122486128 [T/C] rs4255207 9 122487783 [A/G] rs4240461 9 122487902 [A/G] rs7045738 9 122490737 [T/G] rs4240462 9 122491590 [T/C] rs17478596 9 122500393 [A/G] rs16908934 9 122507529 [T/C] rs4836779 9 122510438 [T/G] rs10760059 9 122514849 [A/G] rs3934932 9 122522400 [T/C] rs11795124 9 122525203 [A/G] rs10760062 9 122525788 [A/G] rs10513351 9 122526774 [A/C] rs7854124 9 122528499 [T/C] rs16908978 9 122530528 [A/G] rs2781116 9 122533070 [T/C] rs2781115 9 122533488 [T/G] rs2809898 9 122533710 [T/C] rs10818382 9 122535333 [T/C] rs1360689 9 122538345 [A/G] rs1333891 9 122538992 [A/G] rs1413317 9 122541037 [A/G] rs12376610 9 122544250 [A/C] rs16909026 9 122545688 [T/C] rs2809903 9 122545704 [A/G] rs10984698 9 122545827 [T/G] rs16909036 9 122547228 [T/C] rs4837674 9 122549068 [A/G] rs1360695 9 122549086 [A/G] rs1333913 9 122552939 [T/G] rs13297781 9 122556173 [T/C] rs16909065 9 122557785 [T/C] rs1333903 9 122560262 [T/C] rs10760064 9 122562214 [A/G] rs2151641 9 122566359 [A/G] rs2900162 9 122568511 [T/C] rs2809909 9 122570847 [T/C] rs16909089 9 122570856 [A/G] rs1889274 9 122571328 [T/C] rs2254566 9 122572090 [A/G] rs944961 9 122572896 [T/C] rs4378028 9 122574527 [A/G] rs9299266 9 122574569 [T/C] rs4469535 9 122577120 [T/G] rs7045823 9 122578632 [A/G] rs7859254 9 122578906 [T/C] rs953841 9 122582415 [T/C] rs16909123 9 122582454 [T/C] rs1333914 9 122583234 [T/G] rs7039987 9 122589792 [T/C] rs12551283 9 122591297 [A/G] rs13283350 9 122595692 [A/C] rs1333916 9 122596036 [A/G] rs7046054 9 122607145 [T/C] rs2225659 9 122608692 [A/G] rs4837681 9 122609065 [A/G] rs7849492 9 122619031 [T/C] rs10984725 9 122623813 [A/G] rs1360690 9 122624757 [A/G] rs10984729 9 122625226 [A/C] rs7864914 9 122631415 [A/G] rs10984740 9 122641455 [A/G] rs16909212 9 122643312 [T/C] rs10984757 9 122651883 [T/C] rs11794984 9 122652870 [T/C] rs10818398 9 122656864 [T/C] rs10984766 9 122657312 [A/G] rs10818400 9 122664468 [T/G] rs16936662 9 122664744 [A/C] rs10984768 9 122670569 [A/G] rs1333908 9 122673299 [T/G] rs1333904 9 122674412 [T/C] rs1537510 9 122676538 [A/G] rs7019090 9 122677087 [A/G] rs6478444 9 122681580 [A/G] rs12001524 9 122688434 [T/C] rs7020446 9 122689304 [T/C] rs10120710 9 122697148 [T/C] rs11999958 9 122710349 [A/C] rs2416724 9 122720191 [A/G] rs2900163 9 122720528 [A/G] rs10435885 9 122734446 [T/C] rs6478449 9 122739135 [T/C] rs10984782 9 122740885 [T/C] rs10984786 9 122762260 [A/G] rs2416735 9 122763224 [A/C] rs7872205 9 122763603 [T/C] rs7872465 9 122763797 [T/C] rs7866747 9 122767607 [T/C] rs10818415 9 122771568 [T/C] rs2900167 9 122773855 [T/C] rs10984796 9 122775371 [A/G] rs2002821 9 122776605 [T/C] rs2416740 9 122777336 [A/G] rs2416742 9 122777758 [A/C] rs2416743 9 122777961 [T/C] rs16909325 9 122779915 [A/G] rs10984806 9 122781549 [A/G] rs11794773 9 122782597 [A/G] rs7873896 9 122786574 [T/C] rs6478451 9 122786815 [T/G] rs12344392 9 122791136 [A/G] rs12350202 9 122793550 [A/G] rs6478453 9 122795581 [T/C] rs7851216 9 122799150 [A/G] rs945247 9 122803658 [T/G] rs4836798 9 122810876 [T/C] rs7865756 9 122814965 [T/C] rs10760075 9 122817066 [A/G] rs13302206 9 122829607 [T/G] rs7854483 9 122829654 [T/C] rs4837698 9 122833468 [T/G] rs7870808 9 122839274 [A/G] rs945249 9 122842260 [T/C] rs4837700 9 122846710 [T/C] rs6478456 9 122853291 [A/G] rs12003361 9 122855414 [A/C] rs1981122 9 122856204 [A/C] rs12554672 9 122857993 [A/C] rs7022811 9 122859248 [T/C] rs16909453 9 122865267 [T/C] rs5020365 9 122868699 [A/G] rs10984840 9 122868788 [A/G] rs2416750 9 122873248 [T/G] rs945246 9 122874156 [T/C] rs4837708 9 122887345 [T/G] rs7469446 9 122890954 [A/C] rs1414063 9 122894522 [T/C] rs10760078 9 122894800 [T/C] rs4836804 9 122908894 [A/G] rs4837719 9 122918266 [T/C] rs1335210 9 122937625 [A/G] rs1335211 9 122937656 [A/G] rs10984861 9 122939325 [A/G] rs4837728 9 122954405 [T/C] rs10984865 9 122958532 [T/C] rs10984866 9 122959229 [A/G] rs1860990 9 122960228 [T/G] rs4837732 9 122965218 [T/C] rs13292795 9 122968584 [A/G] rs4836809 9 122972617 [A/C] rs7040919 9 122975509 [A/G] rs4837734 9 122978881 [T/C] rs10733643 9 122991560 [T/C] rs4997435 9 123005508 [A/C] rs10739558 9 123011212 [T/C] rs4837737 9 123011594 [A/G] rs2416755 9 123025230 [A/G] rs759125 9 123041996 [A/G] rs887807 9 123050797 [T/C] rs4837752 9 123056637 [A/G] rs917873 9 123074244 [A/C] rs2159994 9 123075135 [A/G] rs200551 9 123085369 [A/G] rs10984890 9 123088244 [A/G] rs10984892 9 123093411 [T/C] rs200544 9 123099974 [T/C] rs846826 9 123105974 [T/G] rs846836 9 123110588 [T/C] rs1332247 9 123113475 [A/G] rs10818441 9 123114119 [T/C] rs12376794 9 123114345 [T/C] rs7033927 9 123114552 [T/C] rs10818442 9 123115902 [T/C] rs7024514 9 123118155 [A/G] rs1332245 9 123119421 [T/C] rs1112863 9 123122187 [A/G] rs1537282 9 123124504 [T/C] rs1332251 9 123130706 [T/C] rs7852998 9 123133385 [T/C] rs10760096 9 123133808 [T/C] rs7040576 9 123134187 [T/C] rs10818449 9 123137705 [A/G] rs10984898 9 123139224 [A/G] rs10818451 9 123142848 [T/C] rs7030519 9 123144243 [A/G] rs2183906 9 123146316 [A/G] rs7852100 9 123147885 [A/G] rs7028860 9 123148937 [T/G] rs12352904 9 123154442 [T/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7859743 9 123156591 [A/G] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10125592 9 123161735 [A/G] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12379034 9 123162666 [A/G] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3739822 9 123163053 [A/G] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 EXON Silent,Silent,Silent,Synonymous_P1727P,Silent,Synonymous_P1806P,Silent,Synonymous_P1576P rs914592 9 123170167 [A/G] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2297454 9 123171755 [T/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7868021 9 123179940 [A/G] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6478475 9 123182202 [T/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 EXON Silent,Silent,Silent,Synonymous_L1347L,Silent,Synonymous_L1347L,Silent,Synonymous_L1117L rs2900169 9 123185724 [T/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7849947 9 123187872 [A/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4837771 9 123207702 [T/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10984917 9 123211786 [A/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10984920 9 123217710 [T/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2501727 9 123220829 [A/G] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 EXON Silent,Silent,Silent,Synonymous_D758D,Silent,Synonymous_D758D,Silent,Silent rs7869290 9 123225926 [T/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10984922 9 123234422 [T/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10984944 9 123296964 [A/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7868597 9 123298319 [A/G] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3750494 9 123301346 [T/G] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 EXON Silent,Silent,Silent,Synonymous_L160L,Silent,Synonymous_L160L,Silent,Synonymous_L160L rs7854663 9 123305220 [T/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1475663 9 123322700 [A/G] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10984956 9 123324845 [T/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12348950 9 123327435 [T/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4837782 9 123330813 [T/C] NR_073556,NR_073554,NR_073558,NM_001011649,NR_073557,NM_018249,NR_073555,NM_001272039 CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2,CDK5RAP2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10733646 9 123343963 [A/G] rs7861226 9 123351121 [A/C] rs3750495 9 123364934 [T/C] NM_001080497 MEGF9 EXON Silent rs1359329 9 123370985 [A/G] NM_001080497 MEGF9 Silent rs2416760 9 123374639 [T/C] NM_001080497 MEGF9 Silent rs10760109 9 123397576 [T/C] NM_001080497 MEGF9 Silent rs1324473 9 123404610 [T/C] NM_001080497 MEGF9 Silent rs16909987 9 123421732 [A/G] NM_001080497 MEGF9 EXON Synonymous_G241G rs2274144 9 123421879 [A/G] NM_001080497 MEGF9 Silent rs7038900 9 123434601 [T/C] NM_001080497 MEGF9 Silent rs16910027 9 123451103 [A/C] NM_001080497 MEGF9 Silent rs966396 9 123453281 [T/C] NM_001080497 MEGF9 Silent rs7035526 9 123455261 [T/C] NM_001080497 MEGF9 Silent rs10984984 9 123463476 [T/C] NM_001080497 MEGF9 Silent rs10984991 9 123473242 [A/G] NM_001080497 MEGF9 Silent rs4617229 9 123480696 [A/G] rs2416799 9 123480866 [T/G] rs10985011 9 123497595 [A/G] rs2900177 9 123497645 [T/C] rs10985014 9 123498290 [A/G] rs10985015 9 123498335 [T/C] rs10985021 9 123514048 [T/G] rs16910125 9 123520577 [T/C] NM_012164 FBXW2 EXON Silent rs3814536 9 123522115 [A/C] NM_012164 FBXW2 EXON Silent rs4620348 9 123524744 [A/C] NM_012164 FBXW2 EXON Silent rs10985030 9 123525175 [A/C] NM_012164 FBXW2 EXON Silent rs17281564 9 123526731 [A/G] NM_012164 FBXW2 EXON Silent rs16910134 9 123539791 [A/C] NM_012164 FBXW2 Silent rs2416800 9 123544003 [A/G] NM_012164 FBXW2 Silent rs10985036 9 123548885 [A/C] NM_012164 FBXW2 Silent rs7026635 9 123550027 [A/G] NM_012164 FBXW2 Silent rs7873274 9 123559492 [T/C] NR_027442 B3GNT10 Silent rs13285804 9 123560833 [T/C] NR_027442 B3GNT10 Silent rs10985044 9 123563510 [A/G] NR_027442 B3GNT10 EXON Silent rs429254 9 123577920 [A/C] rs6602 9 123578964 [T/C] NM_005047,NM_001270427 PSMD5,PSMD5 EXON Silent,Silent rs1060817 9 123583192 [A/G] NM_005047,NM_001270427 PSMD5,PSMD5 EXON Synonymous_D394D,Synonymous_D351D rs10760117 9 123586737 [T/G] NM_005047,NM_001270427 PSMD5,PSMD5 Silent,Silent rs7021707 9 123604627 [T/C] NM_005047,NM_001270427 PSMD5,PSMD5 Silent,Silent rs10739575 9 123606101 [A/G] NR_152405,NR_152406,NR_024408 CUTALP,CUTALP,CUTALP EXON Silent,Silent,Silent rs933003 9 123607829 [T/C] NR_152405,NR_152406,NR_024408 CUTALP,CUTALP,CUTALP Silent,Silent,Silent rs10985051 9 123607880 [A/C] NR_152405,NR_152406,NR_024408 CUTALP,CUTALP,CUTALP Silent,Silent,Silent rs1063979 9 123609093 [T/C] NR_152405,NR_152406,NR_024408,NR_152407 CUTALP,CUTALP,CUTALP,CUTALP Silent,Silent,Silent,Silent rs12553812 9 123609204 [T/C] NR_152405,NR_152406,NR_024408,NR_152407 CUTALP,CUTALP,CUTALP,CUTALP Silent,Silent,Silent,Silent rs4837796 9 123610288 [T/C] NR_152405,NR_152406,NR_024408,NR_152407 CUTALP,CUTALP,CUTALP,CUTALP Silent,Silent,Silent,Silent rs12379604 9 123616858 [T/G] rs1837 9 123618229 [A/G] NM_015651,NM_001286840,NM_001286842,NR_104601 PHF19,PHF19,PHF19,PHF19 EXON Silent,Silent,Silent,Silent rs914842 9 123618971 [A/G] NM_015651,NM_001286840,NM_001286842,NR_104601 PHF19,PHF19,PHF19,PHF19 EXON Silent,Silent,Silent,Silent rs12377227 9 123626533 [A/G] NM_015651,NM_001286840,NM_001286842,NR_104601 PHF19,PHF19,PHF19,PHF19 Silent,Silent,Silent,Silent rs34475697 9 123630854 [A/G] NM_015651,NM_001286840,NM_001286842,NR_104601 PHF19,PHF19,PHF19,PHF19 Silent,Silent,Silent,Silent rs1056567 9 123632045 [A/G] NM_015651,NM_001286840,NM_001286843,NM_001009936 PHF19,PHF19,PHF19,PHF19 EXON Silent,Silent,Silent,Synonymous_S181S rs3933326 9 123633948 [A/G] NM_015651,NM_001286840,NM_001286843,NM_001009936 PHF19,PHF19,PHF19,PHF19 Silent,Silent,Silent,Silent rs10818477 9 123634029 [T/G] NM_015651,NM_001286840,NM_001286843,NM_001009936 PHF19,PHF19,PHF19,PHF19 Silent,Silent,Silent,Silent rs1609810 9 123642351 [T/C] NM_001286840 PHF19 Silent rs10985073 9 123643855 [T/C] NM_001286840 PHF19 Silent rs881375 9 123652898 [T/C] NM_001286840 PHF19 Silent rs881310 9 123653598 [A/G] NM_001286840 PHF19 Silent rs6478486 9 123655329 [T/C] NM_001286840 PHF19 Silent rs9886724 9 123665019 [A/G] NM_005658,NM_001190947,NM_001190945 TRAF1,TRAF1,TRAF1 EXON Silent,Silent,Silent rs10435844 9 123668199 [T/G] NM_005658,NM_001190947,NM_001190945 TRAF1,TRAF1,TRAF1 Silent,Silent,Silent rs2239657 9 123671520 [A/G] NM_005658,NM_001190947,NM_001190945 TRAF1,TRAF1,TRAF1 EXON Synonymous_P340P,Synonymous_P218P,Synonymous_P340P rs7021880 9 123673890 [C/G] NM_005658,NM_001190947,NM_001190945 TRAF1,TRAF1,TRAF1 Silent,Silent,Silent rs2109895 9 123677827 [T/C] NM_005658,NM_001190945 TRAF1,TRAF1 Silent,Silent rs7021049 9 123683982 [T/G] NM_005658,NM_001190945 TRAF1,TRAF1 Silent,Silent rs1014530 9 123685092 [T/C] NM_005658,NM_001190945 TRAF1,TRAF1 Silent,Silent rs3761847 9 123690239 [A/G] NM_001190945 TRAF1 Silent rs10985095 9 123699083 [A/G] rs10733648 9 123700779 [T/C] rs10985097 9 123703894 [T/C] rs10818488 9 123705087 [A/G] NR_148450 C5-OT1 EXON Silent rs7039505 9 123705945 [A/T] NR_148450 C5-OT1 Silent rs41314063 9 123712883 [T/C] NR_148450 C5-OT1 Silent rs11791179 9 123713203 [T/G] NR_148450 C5-OT1 Silent rs12005198 9 123714395 [A/G] NR_148450 C5-OT1 Silent rs41258306 9 123716103 [T/C] NM_001317163,NM_001735 C5,C5 EXON Synonymous_K1608K,Synonymous_K1602K rs12004487 9 123716681 [T/C] NM_001317163,NM_001735 C5,C5 Silent,Silent rs2300929 9 123716840 [T/C] NM_001317163,NM_001735 C5,C5 Silent,Silent rs7045519 9 123717840 [A/C] NM_001317163,NM_001735 C5,C5 Silent,Silent rs41312915 9 123723479 [A/C] NM_001317163,NM_001735 C5,C5 Silent,Silent rs17612 9 123725926 [T/G] NM_001317163,NM_001735 C5,C5 EXON Missense_E1443D,Missense_E1437D rs7035682 9 123727994 [T/C] NM_001317163,NM_001735 C5,C5 Silent,Silent rs10985112 9 123731408 [A/G] NM_001317163,NM_001735 C5,C5 Silent,Silent rs16910245 9 123732516 [A/G] NM_001317163,NM_001735 C5,C5 EXON Missense_V1371A,Missense_V1365A rs7026551 9 123733133 [A/C] NM_001317163,NM_001735 C5,C5 Silent,Silent rs2269066 9 123737018 [T/C] NM_001317163,NM_001735 C5,C5 Silent,Silent rs10760132 9 123739993 [T/C] NM_001317163,NM_001735 C5,C5 Silent,Silent rs11791407 9 123741822 [T/G] NM_001317163,NM_001735 C5,C5 Silent,Silent rs4837805 9 123746255 [A/G] NM_001317163,NM_001735 C5,C5 Silent,Silent rs7854004 9 123753575 [T/C] NM_001317163,NM_001735 C5,C5 Silent,Silent rs16910255 9 123756983 [T/C] NM_001317163,NM_001735 C5,C5 Silent,Silent rs10760135 9 123763006 [T/C] NM_001317163,NM_001735,NM_001317164 C5,C5,C5 Silent,Silent,Silent rs17611 9 123769200 [T/C] NM_001317163,NM_001735,NM_001317164 C5,C5,C5 EXON Missense_V808I,Missense_V802I,Missense_V802I rs2300932 9 123770436 [A/C] NM_001317163,NM_001735,NM_001317164 C5,C5,C5 Silent,Silent,Silent rs7027797 9 123771799 [T/C] NM_001317163,NM_001735,NM_001317164 C5,C5,C5 Silent,Silent,Silent rs7860179 9 123779781 [T/C] NM_001317163,NM_001735,NM_001317164 C5,C5,C5 EXON Synonymous_L581L,Synonymous_L575L,Synonymous_L575L rs34135565 9 123782278 [A/G] NM_001317163,NM_001735,NM_001317164 C5,C5,C5 EXON Synonymous_D500D,Synonymous_D494D,Synonymous_D494D rs34201541 9 123782415 [T/C] NM_001317163,NM_001735,NM_001317164 C5,C5,C5 EXON Missense_R455G,Missense_R449G,Missense_R449G rs10985126 9 123783934 [T/C] NM_001317163,NM_001735,NM_001317164 C5,C5,C5 EXON Synonymous_G391G,Synonymous_G385G,Synonymous_G385G rs17220750 9 123787999 [A/G] NM_001317163,NM_001735,NM_001317164 C5,C5,C5 Silent,Silent,Silent rs7031128 9 123791936 [A/C] NM_001317163,NM_001735,NM_001317164 C5,C5,C5 Silent,Silent,Silent rs17216529 9 123800218 [T/C] NM_001317163,NM_001735,NM_001317164 C5,C5,C5 EXON Missense_V151I,Missense_V145I,Missense_V145I rs1468673 9 123809890 [T/C] NM_001317163,NM_001735,NM_001317164 C5,C5,C5 Silent,Silent,Silent rs10491537 9 123811632 [A/G] NM_001317163,NM_001735,NM_001317164 C5,C5,C5 Silent,Silent,Silent rs7029523 9 123817613 [T/C] NM_001317163 C5 Silent rs10985140 9 123822837 [A/G] NM_001317163 C5 Silent rs1179766 9 123823972 [T/C] NM_001317163 C5 Silent rs2416815 9 123824021 [A/G] NM_001317163 C5 Silent rs16910300 9 123835199 [T/C] NM_001317163 C5 Silent rs10985148 9 123848837 [A/G] rs10985149 9 123850172 [T/C] rs10818503 9 123850770 [A/G] NM_007018 CNTRL EXON Missense_V56I rs10760146 9 123857085 [T/C] NM_007018 CNTRL Silent rs10733651 9 123858194 [T/G] NM_007018 CNTRL Silent rs10818504 9 123860689 [T/C] NM_007018 CNTRL EXON Missense_P216L rs10156413 9 123867782 [T/C] NM_007018 CNTRL Silent rs2146838 9 123876305 [A/G] NM_007018 CNTRL Silent rs17292952 9 123903840 [A/G] NM_007018,NM_001330762 CNTRL,CNTRL EXON Missense_A889T,Missense_A337T rs3747843 9 123914306 [A/G] NM_007018,NM_001330762 CNTRL,CNTRL Silent,Silent rs4836840 9 123914592 [T/C] NM_007018,NM_001330762 CNTRL,CNTRL Silent,Silent rs9408926 9 123914874 [T/C] NM_007018,NM_001330762 CNTRL,CNTRL EXON Synonymous_L1359L,Synonymous_L807L rs2146836 9 123930296 [A/C] NM_007018,NM_001330762 CNTRL,CNTRL Silent,Silent rs10985171 9 123937156 [A/G] NM_007018,NM_001330762 CNTRL,CNTRL Silent,Silent rs3789311 9 123938998 [T/C] NM_007018,NM_001330762 CNTRL,CNTRL Silent,Silent rs2057470 9 123941122 [A/G] NM_016322 RAB14 EXON Silent rs2296078 9 123943884 [T/C] NM_016322 RAB14 Silent rs942152 9 123951685 [T/C] NM_016322 RAB14 Silent rs10818516 9 123955756 [A/G] NM_016322 RAB14 Silent rs2209076 9 123961405 [A/G] NM_016322 RAB14 Silent rs10739592 9 123971612 [A/G] NM_001353054,NM_001353053 GSN,GSN EXON Silent,Silent rs1590345 9 123985348 [T/C] NM_001353054,NM_001353053 GSN,GSN Silent,Silent rs16910441 9 123997647 [A/C] NM_001353054,NM_001353053 GSN,GSN Silent,Silent rs10760159 9 123998342 [T/C] NM_001353054,NM_001353053 GSN,GSN Silent,Silent rs10760160 9 124003326 [A/C] NM_001353054,NM_001353053 GSN,GSN Silent,Silent rs10985191 9 124014733 [T/C] NM_001353054,NM_001353053 GSN,GSN Silent,Silent rs16910454 9 124015790 [T/C] NM_001353054,NM_001353053 GSN,GSN Silent,Silent rs4556152 9 124016909 [A/G] NM_001353054,NM_001353053 GSN,GSN Silent,Silent rs10760165 9 124021254 [T/C] NM_001353054,NM_001353053 GSN,GSN Silent,Silent rs2239696 9 124029155 [T/C] NM_001353054,NM_001353053 GSN,GSN Silent,Silent rs10985196 9 124033044 [A/C] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs306781 9 124042944 [T/C] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10985200 9 124043867 [T/C] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NR_103560 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN-AS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3810942 9 124044995 [T/C] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NR_103560 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN-AS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7046030 9 124047237 [T/C] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NR_103560 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN-AS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs913767 9 124047246 [A/C] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NR_103560 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN-AS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1078305 9 124051400 [A/G] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NM_001258029,NM_001258030 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3827677 9 124060879 [T/C] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NM_001258029,NM_001258030 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs913763 9 124067789 [A/G] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NM_001258029,NM_001258030,NM_001353075,NM_001353077,NM_000177 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs306784 9 124072652 [T/G] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NM_001258029,NM_001258030,NM_001353075,NM_001353077,NM_000177 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2039144 9 124074420 [A/G] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NM_001258029,NM_001258030,NM_001353075,NM_001353077,NM_000177 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs306761 9 124075544 [A/G] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NM_001258029,NM_001258030,NM_001353075,NM_001353077,NM_000177 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2304393 9 124083614 [T/C] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NM_001258029,NM_001258030,NM_001353075,NM_001353077,NM_000177 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN EXON Synonymous_G420G,Synonymous_G420G,Synonymous_G431G,Synonymous_G420G,Synonymous_G420G,Synonymous_G431G,Synonymous_G420G,Synonymous_G420G,Synonymous_G420G,Synonymous_G431G,Synonymous_G420G,Synonymous_G420G,Synonymous_G431G,Synonymous_G431G,Synonymous_G431G,Synonymous_G420G,Synonymous_G420G,Synonymous_G431G,Synonymous_G444G,Synonymous_G431G,Synonymous_G420G,Synonymous_G456G,Synonymous_G431G,Synonymous_G431G,Synonymous_G420G,Synonymous_G431G,Synonymous_G431G,Synonymous_G431G,Synonymous_G431G,Synonymous_G202G,Synonymous_G420G,Synonymous_G437G,Synonymous_G428G,Synonymous_G431G,Synonymous_G431G,Synonymous_G471G rs12683989 9 124086046 [T/C] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NM_001258029,NM_001258030,NM_001353075,NM_001353077,NM_000177 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs306770 9 124090784 [A/G] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NM_001258029,NM_001258030,NM_001353075,NM_001353077,NM_000177 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs306772 9 124092355 [T/C] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NM_001258029,NM_001258030,NM_001353075,NM_001353077,NM_000177 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs446038 9 124093940 [A/G] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NM_001258029,NM_001258030,NM_001353075,NM_001353077,NM_000177 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs364814 9 124094014 [A/G] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NM_001258029,NM_001258030,NM_001353075,NM_001353077,NM_000177 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10985210 9 124094435 [T/C] NM_001353054,NM_001353053,NM_001353065,NM_001353056,NM_001353057,NM_001127667,NM_001353059,NM_001353058,NM_001353060,NM_001353064,NM_001127665,NM_001353055,NM_001353072,NM_001353070,NM_001353069,NM_198252,NM_001353061,NM_001353066,NM_001353076,NM_001353067,NM_001127662,NM_001127663,NM_001353068,NM_001353074,NM_001127664,NM_001353071,NM_001353073,NM_001127666,NM_001353063,NM_001353078,NM_001353062,NM_001258029,NM_001258030,NM_001353075,NM_001353077,NM_000177 GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN,GSN Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs398720 9 124095271 [A/C] rs767769 9 124098336 [A/G] rs12351310 9 124099125 [A/G] rs16910556 9 124102350 [T/C] NM_001270526,NM_004099,NR_073037,NM_198194,NM_001270527 STOM,STOM,STOM,STOM,STOM EXON Silent,Silent,Silent,Silent,Silent rs7853284 9 124103759 [A/G] NM_001270526,NM_004099,NR_073037,NM_198194,NM_001270527 STOM,STOM,STOM,STOM,STOM Silent,Silent,Silent,Silent,Silent rs306793 9 124109022 [A/C] NM_001270526,NM_004099,NR_073037,NM_198194,NM_001270527 STOM,STOM,STOM,STOM,STOM Silent,Silent,Silent,Silent,Silent rs3747846 9 124118776 [A/G] NM_001270526,NM_004099,NR_073037,NM_198194,NM_001270527 STOM,STOM,STOM,STOM,STOM Silent,Silent,Silent,Silent,Silent rs17086 9 124125520 [A/G] NM_001270526,NM_004099,NR_073037,NM_198194,NM_001270527 STOM,STOM,STOM,STOM,STOM Silent,Silent,Silent,Silent,Silent rs16910566 9 124126618 [A/G] NM_001270526,NM_004099,NR_073037,NM_198194,NM_001270527 STOM,STOM,STOM,STOM,STOM Silent,Silent,Silent,Silent,Silent rs306796 9 124127335 [T/C] NM_001270526,NM_004099,NR_073037,NM_198194,NM_001270527 STOM,STOM,STOM,STOM,STOM Silent,Silent,Silent,Silent,Silent rs167396 9 124128354 [A/C] NM_001270526,NM_004099,NR_073037,NM_198194,NM_001270527 STOM,STOM,STOM,STOM,STOM Silent,Silent,Silent,Silent,Silent rs367395 9 124131512 [A/C] NM_001270526,NM_004099,NR_073037,NM_198194,NM_001270527 STOM,STOM,STOM,STOM,STOM Silent,Silent,Silent,Silent,Silent rs7047206 9 124131731 [T/G] NM_001270526,NM_004099,NR_073037,NM_198194,NM_001270527 STOM,STOM,STOM,STOM,STOM Silent,Silent,Silent,Silent,Silent rs3761853 9 124135334 [T/C] rs424829 9 124160616 [T/C] rs2196311 9 124170490 [A/C] rs12682698 9 124189101 [A/C] rs306777 9 124192482 [T/C] rs177698 9 124200417 [T/C] rs4837853 9 124213962 [T/C] rs6478510 9 124227499 [A/G] NR_003191,NR_045211 GGTA1P,GGTA1P Silent,Silent rs10818548 9 124238924 [A/G] NR_003191,NR_045211 GGTA1P,GGTA1P Silent,Silent rs1557033 9 124242016 [T/C] NR_003191,NR_045211 GGTA1P,GGTA1P Silent,Silent rs10985272 9 124252503 [A/G] NR_003191,NR_045211 GGTA1P,GGTA1P Silent,Silent rs12551532 9 124253751 [T/C] NR_003191,NR_045211 GGTA1P,GGTA1P Silent,Silent rs10985274 9 124259751 [T/G] NR_003191,NR_045211 GGTA1P,GGTA1P Silent,Silent rs4836853 9 124280991 [T/G] rs10760179 9 124282782 [T/C] rs12551209 9 124283089 [A/G] rs7854285 9 124288948 [T/C] rs4837876 9 124295569 [T/C] rs10985311 9 124303632 [T/C] rs478352 9 124303655 [T/G] rs7873850 9 124308077 [A/C] rs475972 9 124320762 [A/G] rs1107811 9 124325541 [T/C] rs7867606 9 124326028 [T/C] rs7042758 9 124328194 [T/C] rs657239 9 124330141 [T/C] NM_032552 DAB2IP Silent rs10985320 9 124330970 [T/C] NM_032552 DAB2IP Silent rs556331 9 124336665 [A/C] NM_032552 DAB2IP Silent rs7045915 9 124337517 [T/C] NM_032552 DAB2IP Silent rs476951 9 124337762 [A/G] NM_032552 DAB2IP Silent rs4310275 9 124339034 [T/G] NM_032552 DAB2IP Silent rs914388 9 124343306 [A/G] NM_032552 DAB2IP Silent rs603315 9 124343700 [T/C] NM_032552 DAB2IP Silent rs883095 9 124344438 [A/G] NM_032552 DAB2IP Silent rs587936 9 124344832 [T/C] NM_032552 DAB2IP Silent rs634328 9 124349322 [T/G] NM_032552 DAB2IP Silent rs10513376 9 124354826 [T/C] NM_032552 DAB2IP Silent rs2777319 9 124362502 [T/C] NM_032552 DAB2IP Silent rs7021714 9 124364349 [T/C] NM_032552 DAB2IP Silent rs10818569 9 124364572 [T/C] NM_032552 DAB2IP Silent rs2777317 9 124368674 [A/G] NM_032552 DAB2IP Silent rs10985332 9 124372152 [T/C] NM_032552 DAB2IP Silent rs10985334 9 124372312 [T/C] NM_032552 DAB2IP Silent rs692910 9 124373089 [A/G] NM_032552 DAB2IP Silent rs605576 9 124376589 [T/G] NM_032552 DAB2IP Silent rs1984035 9 124379788 [T/C] NM_032552 DAB2IP Silent rs2789876 9 124383244 [T/C] NM_032552 DAB2IP Silent rs2789875 9 124384647 [A/G] NM_032552 DAB2IP Silent rs7863224 9 124388306 [A/G] NM_032552 DAB2IP Silent rs520198 9 124390320 [T/C] NM_032552 DAB2IP Silent rs871214 9 124394575 [T/G] NM_032552 DAB2IP Silent rs2797349 9 124396753 [A/C] NM_032552 DAB2IP Silent rs584985 9 124397290 [T/C] NM_032552 DAB2IP Silent rs2777310 9 124399756 [A/G] NM_032552 DAB2IP Silent rs12553641 9 124407976 [A/G] NM_032552 DAB2IP Silent rs12554667 9 124410605 [T/G] NM_032552 DAB2IP Silent rs10760182 9 124412961 [A/G] NM_032552 DAB2IP Silent rs13289585 9 124420789 [T/C] NM_032552 DAB2IP Silent rs10985349 9 124425243 [T/C] NM_032552 DAB2IP Silent rs1571801 9 124427373 [T/G] NM_032552 DAB2IP Silent rs7029095 9 124436035 [A/G] NM_032552 DAB2IP Silent rs7028742 9 124436050 [A/G] NM_032552 DAB2IP Silent rs7875955 9 124438732 [A/C] NM_032552 DAB2IP Silent rs7047340 9 124441404 [T/G] NM_032552 DAB2IP Silent rs12350358 9 124441657 [A/G] NM_032552 DAB2IP Silent rs870556 9 124444109 [T/C] NM_032552 DAB2IP Silent rs2051053 9 124445115 [T/C] NM_032552 DAB2IP Silent rs2900195 9 124449142 [A/C] NM_032552 DAB2IP Silent rs16910935 9 124449774 [T/C] NM_032552 DAB2IP Silent rs12005338 9 124457337 [A/C] NM_032552 DAB2IP Silent rs7040850 9 124457949 [T/G] NM_032552 DAB2IP Silent rs7033645 9 124467254 [A/G] NM_032552 DAB2IP Silent rs7849916 9 124479782 [T/C] NM_032552 DAB2IP Silent rs13290547 9 124487495 [T/C] NM_032552 DAB2IP Silent rs12685856 9 124516590 [T/C] NM_032552,NM_138709 DAB2IP,DAB2IP Silent,Silent rs16910952 9 124518579 [T/C] NM_032552,NM_138709 DAB2IP,DAB2IP Silent,Silent rs3747851 9 124521260 [A/G] NM_032552,NM_138709 DAB2IP,DAB2IP EXON Synonymous_A172A,Synonymous_A76A rs7045538 9 124533221 [A/G] NM_032552,NM_138709 DAB2IP,DAB2IP Silent,Silent rs10985372 9 124546143 [A/G] NM_032552 DAB2IP EXON Silent rs12002566 9 124547594 [T/C] NM_032552 DAB2IP EXON Silent rs10985376 9 124550237 [T/C] rs12238806 9 124550994 [T/G] rs12685888 9 124551766 [T/C] rs10985387 9 124559790 [A/G] rs10818593 9 124560853 [T/C] rs12347373 9 124567667 [A/G] rs4641136 9 124571484 [A/G] rs7858071 9 124572031 [T/C] rs10116392 9 124573625 [T/C] rs1129678 9 124578338 [T/C] rs3802488 9 124583411 [T/C] rs10818600 9 124589809 [A/G] NM_001139442 TTLL11 Silent rs7862029 9 124600375 [T/G] NM_001139442 TTLL11 Silent rs7039561 9 124602102 [A/G] NM_001139442 TTLL11 Silent rs12348475 9 124604264 [A/G] NM_001139442 TTLL11 Silent rs10818602 9 124606788 [T/C] NM_001139442 TTLL11 Silent rs4308811 9 124613105 [A/G] NM_001139442 TTLL11 Silent rs10818605 9 124614496 [T/C] NM_001139442 TTLL11 Silent rs7864184 9 124617259 [T/G] NM_001139442 TTLL11 Silent rs13295845 9 124619225 [A/G] NM_001139442 TTLL11 Silent rs4836866 9 124620787 [A/G] NM_001139442 TTLL11 Silent rs10739600 9 124623873 [A/G] NM_001139442 TTLL11 Silent rs4538956 9 124625023 [T/G] NM_001139442 TTLL11 Silent rs7863807 9 124625886 [A/G] NM_001139442 TTLL11 Silent rs10513383 9 124627927 [T/G] NM_001139442 TTLL11 Silent rs16911057 9 124628199 [A/G] NM_001139442 TTLL11 Silent rs7047365 9 124630333 [T/C] NM_001139442 TTLL11 Silent rs4503172 9 124640841 [T/C] NM_001139442 TTLL11 Silent rs7033700 9 124643095 [T/C] NM_001139442 TTLL11 Silent rs6478545 9 124643367 [T/C] NM_001139442 TTLL11 Silent rs7871736 9 124650611 [T/C] NM_001139442 TTLL11 Silent rs10985431 9 124651790 [T/C] NM_001139442 TTLL11 Silent rs4271039 9 124661100 [A/G] NM_001139442 TTLL11 Silent rs4518734 9 124668198 [A/G] NM_001139442 TTLL11 Silent rs9408931 9 124675677 [A/G] NM_001139442 TTLL11 Silent rs7019301 9 124676496 [T/C] NM_001139442 TTLL11 Silent rs11793905 9 124678508 [T/C] NM_001139442 TTLL11 Silent rs2416835 9 124679214 [T/C] NM_001139442 TTLL11 Silent rs2416837 9 124680367 [T/G] NM_001139442 TTLL11 Silent rs13295747 9 124685499 [T/C] NM_001139442 TTLL11 Silent rs6478548 9 124687446 [T/C] NM_001139442 TTLL11 Silent rs4344151 9 124693697 [A/C] NM_001139442 TTLL11 Silent rs9409243 9 124694838 [T/C] NM_001139442 TTLL11 Silent rs11999315 9 124697074 [T/C] NM_001139442 TTLL11 Silent rs13295532 9 124697877 [T/C] NM_001139442 TTLL11 Silent rs2416841 9 124701103 [T/C] NM_001139442 TTLL11 Silent rs10985459 9 124703332 [T/C] NM_001139442 TTLL11 Silent rs10739601 9 124704304 [A/C] NM_001139442 TTLL11 Silent rs10739602 9 124710228 [A/C] NM_001139442 TTLL11 Silent rs2416848 9 124711549 [A/G] NM_001139442 TTLL11 Silent rs7028210 9 124712136 [A/G] NM_001139442 TTLL11 Silent rs12379136 9 124716151 [A/G] NM_001139442 TTLL11 Silent rs9409246 9 124718909 [T/G] NM_001139442 TTLL11 Silent rs4837923 9 124720937 [T/G] NM_001139442 TTLL11 Silent rs10985469 9 124723489 [A/G] NM_001139442 TTLL11 Silent rs2416843 9 124723960 [T/C] NM_001139442 TTLL11 Silent rs4534187 9 124736081 [A/G] NM_001139442 TTLL11 Silent rs16911180 9 124738711 [T/C] NM_001139442 TTLL11 Silent rs6478551 9 124740606 [T/C] NM_001139442 TTLL11 Silent rs7019095 9 124747323 [T/C] NM_001139442 TTLL11 Silent rs17177082 9 124747765 [A/G] NM_001139442 TTLL11 Silent rs16911189 9 124749834 [T/C] NM_001139442 TTLL11 Silent rs10739604 9 124754815 [A/G] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs4836872 9 124756264 [A/G] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs10985478 9 124759431 [T/C] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs7856664 9 124767036 [A/C] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs16911266 9 124778409 [T/C] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs13289318 9 124779322 [A/G] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs11506930 9 124786156 [T/C] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs10125937 9 124790623 [T/C] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs17178044 9 124798680 [T/C] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs4837936 9 124810592 [A/C] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs7045782 9 124818049 [T/C] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs10513389 9 124821226 [A/G] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs16911368 9 124831273 [T/C] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs10818623 9 124835368 [T/C] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs7860331 9 124852286 [T/C] NM_001139442,NM_194252 TTLL11,TTLL11 Silent,Silent rs10985526 9 124863020 [A/G] rs12551572 9 124864385 [T/G] rs10985529 9 124869062 [T/G] rs7034156 9 124870192 [T/C] rs7021304 9 124870596 [T/C] rs13287142 9 124870612 [A/G] rs2247680 9 124871697 [A/G] rs10985532 9 124876341 [A/G] rs7861047 9 124877059 [T/C] rs11793614 9 124879007 [T/C] rs10985538 9 124884007 [T/C] rs7038781 9 124885254 [A/G] rs7042153 9 124885596 [A/C] rs1411451 9 124893355 [T/C] rs1983985 9 124895008 [T/C] NM_001318195 NDUFA8 EXON Silent rs1124729 9 124900274 [A/G] NM_001318195 NDUFA8 Silent rs9775695 9 124900788 [T/C] NM_001318195 NDUFA8 Silent rs1536958 9 124901941 [T/C] NM_001318195 NDUFA8 Silent rs4147660 9 124905629 [A/G] NM_001318195 NDUFA8 Silent rs6822 9 124906456 [T/C] NM_001318195,NM_014222 NDUFA8,NDUFA8 EXON Silent,Silent rs4147658 9 124906519 [T/C] NM_001318195,NM_014222 NDUFA8,NDUFA8 EXON Silent,Silent rs3818638 9 124906723 [T/C] NM_001318195,NM_014222 NDUFA8,NDUFA8 Silent,Silent rs3793616 9 124910582 [A/C] NM_001318195,NM_014222 NDUFA8,NDUFA8 Silent,Silent rs12686688 9 124913308 [A/C] NM_001318195,NM_014222 NDUFA8,NDUFA8 Silent,Silent rs10818639 9 124918150 [A/C] NM_001318195,NM_014222 NDUFA8,NDUFA8 Silent,Silent rs7875039 9 124918545 [T/C] NM_001318195,NM_014222 NDUFA8,NDUFA8 Silent,Silent rs1411445 9 124918682 [A/G] NM_001318195,NM_014222 NDUFA8,NDUFA8 Silent,Silent rs12345130 9 124921518 [A/G] NM_001318195,NM_014222 NDUFA8,NDUFA8 Silent,Silent rs10985554 9 124924543 [A/G] NM_198469,NM_001286828 MORN5,MORN5 Silent,Silent rs950019 9 124925605 [T/C] NM_198469,NM_001286828 MORN5,MORN5 Silent,Silent rs7466389 9 124929161 [T/C] NM_198469,NM_001286828 MORN5,MORN5 EXON Synonymous_Y54Y,Synonymous_Y54Y rs10985555 9 124930771 [T/G] NM_198469,NM_001286828 MORN5,MORN5 Silent,Silent rs10818642 9 124935044 [A/G] NM_198469,NM_001286828 MORN5,MORN5 Silent,Silent rs1010804 9 124941854 [T/G] NM_198469,NM_001286828 MORN5,MORN5 Silent,Silent rs10760211 9 124945604 [T/C] NM_198469,NM_001286828 MORN5,MORN5 Silent,Silent rs7869304 9 124946021 [A/G] NM_198469,NM_001286828 MORN5,MORN5 Silent,Silent rs2039197 9 124949046 [A/G] NM_198469,NM_001286828 MORN5,MORN5 Silent,Silent rs913933 9 124949538 [T/C] NM_198469,NM_001286828 MORN5,MORN5 Silent,Silent rs2039196 9 124949601 [A/G] NM_198469,NM_001286828 MORN5,MORN5 Silent,Silent rs870272 9 124953560 [T/C] NM_198469,NM_001286828 MORN5,MORN5 Silent,Silent rs7855478 9 124955028 [A/G] NM_198469,NM_001286828 MORN5,MORN5 Silent,Silent rs1571586 9 124957525 [A/G] NM_198469,NM_001286828 MORN5,MORN5 Silent,Silent rs12683922 9 124958572 [A/G] NM_198469,NM_001286828 MORN5,MORN5 Silent,Silent rs10985563 9 124965702 [T/C] NM_001242333,NM_001348190,NM_001242334,NM_014368,NM_199160,NM_001242335 LHX6,LHX6,LHX6,LHX6,LHX6,LHX6 EXON Silent,Silent,Silent,Silent,Silent,Silent rs3750486 9 124966261 [A/G] NM_001242333,NM_001348190,NM_001242334,NM_014368,NM_199160,NM_001242335 LHX6,LHX6,LHX6,LHX6,LHX6,LHX6 EXON Silent,Silent,Silent,Silent,Silent,Silent rs3793617 9 124966449 [T/C] NM_001242333,NM_001348190,NM_001242334,NM_014368,NM_199160,NM_001242335 LHX6,LHX6,LHX6,LHX6,LHX6,LHX6 EXON Silent,Silent,Silent,Silent,Silent,Silent rs10818647 9 124967776 [T/C] NM_001242333,NM_001348190,NM_001242334,NM_014368,NM_199160,NM_001242335 LHX6,LHX6,LHX6,LHX6,LHX6,LHX6 Silent,Silent,Silent,Silent,Silent,Silent rs10818649 9 124969315 [T/C] NM_001242333,NM_001348190,NM_001242334,NM_014368,NM_199160,NM_001242335 LHX6,LHX6,LHX6,LHX6,LHX6,LHX6 Silent,Silent,Silent,Silent,Silent,Silent rs10818651 9 124974419 [A/G] NM_001242333,NM_001348190,NM_001242334,NM_014368,NM_199160,NM_001242335 LHX6,LHX6,LHX6,LHX6,LHX6,LHX6 Silent,Silent,Silent,Silent,Silent,Silent rs10985568 9 124980026 [T/C] NM_001242333,NM_001348190,NM_001242334,NM_014368,NM_199160,NM_001242335 LHX6,LHX6,LHX6,LHX6,LHX6,LHX6 Silent,Silent,Silent,Silent,Silent,Silent rs3793621 9 124984125 [A/G] NM_001242333,NM_001348190,NM_001242334,NM_014368,NM_199160 LHX6,LHX6,LHX6,LHX6,LHX6 Silent,Silent,Silent,Silent,Silent rs12345155 9 124985250 [T/C] NM_001242333,NM_001348190,NM_001242334,NM_014368,NM_199160 LHX6,LHX6,LHX6,LHX6,LHX6 Silent,Silent,Silent,Silent,Silent rs10818652 9 124985785 [A/G] NM_001242333,NM_001348190,NM_001242334,NM_014368,NM_199160 LHX6,LHX6,LHX6,LHX6,LHX6 Silent,Silent,Silent,Silent,Silent rs3808901 9 124992671 [A/G] rs3808900 9 124992764 [A/G] rs7849627 9 124993505 [A/G] rs4837951 9 124995282 [A/G] rs1571585 9 124998225 [A/G] rs10733657 9 125001985 [T/C] NR_027125,NR_027126,NM_033117 RBM18,RBM18,RBM18 EXON Silent,Silent,Silent rs10818655 9 125002275 [T/C] NR_027125,NR_027126,NM_033117 RBM18,RBM18,RBM18 EXON Silent,Silent,Silent rs16911568 9 125002968 [A/G] NR_027125,NR_027126,NM_033117 RBM18,RBM18,RBM18 EXON Silent,Silent,Silent rs1060586 9 125003679 [A/G] NR_027125,NR_027126,NM_033117 RBM18,RBM18,RBM18 EXON Silent,Silent,Silent rs10739606 9 125003751 [T/C] NR_027125,NR_027126,NM_033117 RBM18,RBM18,RBM18 EXON Silent,Silent,Silent rs11794068 9 125006622 [A/C] NR_027125,NR_027126,NM_033117 RBM18,RBM18,RBM18 Silent,Silent,Silent rs12555156 9 125024291 [A/G] NR_027125,NR_027126,NM_033117 RBM18,RBM18,RBM18 Silent,Silent,Silent rs7034992 9 125026664 [A/G] NR_027125,NR_027126,NM_033117 RBM18,RBM18,RBM18 Silent,Silent,Silent rs9695213 9 125043555 [A/G] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16911577 9 125044199 [T/C] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10818673 9 125044448 [A/G] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12005662 9 125047930 [A/G] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs954451 9 125051096 [A/C] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10513396 9 125055170 [A/G] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16911600 9 125056003 [T/C] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7029404 9 125060822 [A/G] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10985588 9 125061280 [A/G] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2026152 9 125063820 [A/G] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7019478 9 125065423 [A/C] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12686776 9 125066774 [A/G] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16911615 9 125068857 [A/G] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17273828 9 125069187 [A/G] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10985591 9 125070415 [T/C] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17273863 9 125073093 [A/G] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12002123 9 125074672 [T/C] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2297483 9 125075600 [A/G] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF EXON Silent,Missense_M216V,Missense_N185S,Missense_M125V,Missense_M216V,Missense_M172V,Missense_M237V,Missense_M164V,Silent rs3818711 9 125075782 [A/C] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10119462 9 125078915 [A/G] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10985594 9 125081147 [T/C] NR_144421,NM_138777,NM_001346345,NM_001346347,NM_001346341,NM_001346343,NM_001346339,NM_001173512,NM_199177 MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF,MRRF Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10985596 9 125089260 [T/C] rs7049102 9 125102160 [T/C] rs13283472 9 125105790 [T/G] rs7871157 9 125109939 [A/C] rs7022025 9 125111953 [A/G] rs7029883 9 125117174 [T/C] rs4837960 9 125123971 [T/G] rs10306108 9 125131480 [T/C] rs10306109 9 125131631 [A/G] rs1236913 9 125133479 [T/C] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 EXON Silent,Silent,Silent,Missense_W8R,Missense_W8R,Missense_W8R rs1213266 9 125136884 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 Silent,Silent,Silent,Silent,Silent,Silent rs10306133 9 125137644 [T/C] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10985627 9 125139318 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3842788 9 125140206 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 EXON Synonymous_Q16Q,Silent,Silent,Synonymous_Q41Q,Synonymous_Q41Q,Synonymous_Q41Q,Silent rs3842789 9 125140241 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 EXON Missense_R28H,Silent,Silent,Missense_R53H,Missense_R53H,Missense_R53H,Silent rs10306227 9 125140500 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10306143 9 125141786 [T/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs5788 9 125143792 [A/C] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 EXON Synonymous_G188G,Synonymous_G104G,Synonymous_G104G,Synonymous_G213G,Synonymous_G213G,Synonymous_G165G,Synonymous_G104G rs5789 9 125143973 [A/C] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 EXON Missense_L212M,Missense_L128M,Missense_L128M,Missense_L237M,Missense_L237M,Missense_L189M,Missense_L128M rs10306230 9 125146379 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10306156 9 125146701 [T/C] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4836886 9 125146895 [T/C] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9299281 9 125147871 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9299283 9 125147931 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6478565 9 125148632 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10306162 9 125149958 [T/C] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10306163 9 125149970 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12551233 9 125150888 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs5794 9 125152621 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 EXON Missense_V419I,Missense_V335I,Missense_V335I,Missense_V444I,Missense_V481I,Missense_V433I,Missense_V372I rs7874531 9 125153352 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs8046 9 125155408 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10306188 9 125155685 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10306192 9 125155930 [G/C] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10306194 9 125157198 [A/C] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10306196 9 125157316 [A/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9233 9 125157718 [T/G] NM_001271368,NM_001271166,NM_001271367,NM_080591,NM_000962,NM_001271164,NM_001271165 PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1,PTGS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10513402 9 125164936 [T/C] rs950104 9 125165225 [A/G] rs10818684 9 125169930 [T/C] rs1758701 9 125177491 [T/C] rs1234909 9 125186011 [A/G] rs1332408 9 125192159 [A/C] rs2778624 9 125209061 [T/C] rs2778635 9 125229799 [A/G] rs1332406 9 125230685 [A/G] rs2778636 9 125231092 [A/G] rs7865902 9 125233864 [T/G] rs1888941 9 125236148 [T/C] rs1228138 9 125238040 [T/C] rs1547929 9 125246793 [A/G] rs2416863 9 125252977 [A/G] rs7048727 9 125253682 [A/G] rs7022194 9 125254955 [A/G] rs10985655 9 125255361 [T/G] rs1592031 9 125255623 [T/C] rs11496595 9 125257838 [T/C] rs2096064 9 125261468 [A/G] rs10739609 9 125265317 [T/G] rs10985658 9 125265496 [A/G] rs12380552 9 125266798 [T/G] rs1556190 9 125268884 [A/G] rs7873246 9 125271022 [A/G] rs7019219 9 125271839 [A/G] rs10985662 9 125272062 [A/C] rs4836891 9 125273574 [A/G] NM_054107 OR1J2 EXON Missense_R165Q rs1329954 9 125274730 [T/C] rs10985663 9 125276105 [A/G] rs12349388 9 125276867 [A/G] rs10120714 9 125281127 [A/G] rs10985667 9 125282970 [T/G] rs10985670 9 125287430 [T/C] rs16911867 9 125289083 [A/G] NM_012363 OR1N1 EXON Synonymous_L164L rs10818708 9 125289521 [A/G] NM_012363 OR1N1 EXON Missense_P18S rs10760228 9 125290397 [A/G] rs2104751 9 125298845 [T/C] rs7037327 9 125303760 [A/G] rs1041356 9 125304750 [T/C] rs10760235 9 125307248 [T/C] rs978477 9 125308131 [T/C] rs3983868 9 125314024 [T/C] rs2416875 9 125314400 [T/C] rs7859232 9 125314885 [A/G] rs7031561 9 125315107 [A/C] rs12684786 9 125315393 [A/G] rs1831369 9 125315542 [T/C] NM_001004457 OR1N2 EXON Synonymous_L32L rs1831370 9 125315557 [T/C] NM_001004457 OR1N2 EXON Missense_W37R rs1341043 9 125316042 [T/C] NM_001004457 OR1N2 EXON Synonymous_P198P rs1341044 9 125316179 [T/G] NM_001004457 OR1N2 EXON Missense_V244G rs1411272 9 125316350 [T/C] NM_001004457 OR1N2 EXON Missense_T301M rs10985690 9 125316850 [T/C] rs10760239 9 125317485 [T/G] rs2183328 9 125318521 [T/C] rs2183326 9 125318782 [A/G] rs10985700 9 125325182 [A/G] rs4836894 9 125328122 [T/C] rs10513416 9 125328865 [A/G] rs10985702 9 125330184 [A/C] NM_001004454 OR1L8 EXON Synonymous_S191S rs10985704 9 125330678 [T/G] NM_001004454 OR1L8 EXON Missense_T27P rs1411265 9 125331205 [T/C] rs7860446 9 125332930 [T/C] rs12376146 9 125335216 [T/C] rs10119609 9 125339689 [T/C] rs7867785 9 125340264 [T/C] rs2050898 9 125342209 [A/G] rs959550 9 125343746 [A/C] rs10818721 9 125349081 [T/G] rs10985729 9 125364208 [A/G] rs960576 9 125365505 [A/G] rs10818729 9 125371916 [T/C] rs1556191 9 125372766 [T/C] rs1000510 9 125372878 [T/G] rs16911946 9 125372970 [A/G] rs4836901 9 125375428 [A/G] rs972926 9 125376842 [T/C] rs972925 9 125377087 [A/G] NM_012364 OR1Q1 EXON Missense_Q24R rs727913 9 125377734 [A/G] NM_012364 OR1Q1 EXON Missense_T240A rs10985736 9 125383758 [T/C] rs10124314 9 125384197 [T/C] rs10739616 9 125384788 [A/G] rs10760244 9 125385408 [A/C] rs12000807 9 125386182 [T/C] rs11792470 9 125387735 [A/G] rs10491515 9 125387853 [A/G] rs4836903 9 125390773 [T/C] rs1556189 9 125390874 [A/C] NM_001004450 OR1B1 EXON Missense_V314G rs1476858 9 125391026 [A/C] NM_001004450 OR1B1 EXON Missense_C263W rs1476859 9 125391127 [T/C] NM_001004450 OR1B1 EXON Missense_A230T rs1476860 9 125391241 [A/G] NM_001004450 OR1B1 EXON Nonsense_R192X rs1536929 9 125391369 [A/G] NM_001004450 OR1B1 EXON Missense_L149S rs1536928 9 125391409 [A/G] NM_001004450 OR1B1 EXON Synonymous_L136L rs2041474 9 125398582 [T/C] rs16912015 9 125400380 [A/G] rs7859421 9 125402874 [A/G] rs1928624 9 125415365 [A/G] rs2215532 9 125418870 [A/C] rs2416891 9 125422424 [A/G] rs237617 9 125422865 [A/G] rs70157 9 125424277 [A/G] NM_001005236 OR1L1 EXON Missense_S95G rs237622 9 125425560 [T/C] rs237623 9 125425569 [A/G] rs7027867 9 125426554 [T/C] rs7035512 9 125433467 [A/G] rs16912081 9 125435311 [A/C] rs7044945 9 125436147 [A/G] rs16912096 9 125437725 [T/C] NM_001005234 OR1L3 EXON Missense_V106A rs16912099 9 125437769 [A/G] NM_001005234 OR1L3 EXON Missense_N121D rs16912101 9 125438077 [T/C] NM_001005234 OR1L3 EXON Synonymous_I223I rs16912104 9 125439189 [T/G] rs10985748 9 125444045 [A/G] rs12238140 9 125453469 [T/C] rs764373 9 125464010 [T/C] rs12002657 9 125465183 [T/C] rs4571792 9 125478541 [A/G] rs12380462 9 125479993 [T/C] rs7032935 9 125485748 [T/C] rs10429618 9 125491426 [A/G] rs12237468 9 125491634 [T/C] rs2191696 9 125492612 [T/C] rs7046355 9 125502869 [T/C] rs10120579 9 125511661 [A/G] rs2416893 9 125517223 [T/C] rs10156486 9 125538981 [A/C] rs2050871 9 125542513 [T/G] rs7855480 9 125550259 [T/C] rs2535739 9 125554766 [A/G] rs2535742 9 125559860 [T/G] rs7849259 9 125560607 [A/G] rs16912238 9 125573030 [A/G] rs11790713 9 125573235 [T/C] rs10123214 9 125578175 [T/G] rs16912239 9 125582138 [A/C] NM_005388 PDCL EXON Silent rs4997232 9 125582173 [T/C] NM_005388 PDCL EXON Silent rs10818752 9 125585909 [A/G] NM_005388 PDCL Silent rs7037776 9 125588724 [T/C] NM_005388 PDCL Silent rs3802487 9 125590647 [A/G] NM_005388 PDCL Silent rs16912256 9 125591426 [T/C] rs10818753 9 125601801 [A/G] rs10513414 9 125605708 [T/C] rs10985793 9 125606191 [A/C] rs10985794 9 125606617 [T/C] rs10818754 9 125608627 [T/C] NM_001354479,NM_001354478,NM_001100588,NM_001354482 RC3H2,RC3H2,RC3H2,RC3H2 EXON Silent,Silent,Silent,Silent rs12001002 9 125611369 [T/C] NM_001354479,NM_001354478,NM_001100588,NM_001354482 RC3H2,RC3H2,RC3H2,RC3H2 EXON Silent,Silent,Silent,Silent rs1375862 9 125617037 [A/G] NM_001354479,NM_001354478,NM_001100588,NM_001354482,NM_018835 RC3H2,RC3H2,RC3H2,RC3H2,RC3H2 Silent,Silent,Silent,Silent,Silent rs7033878 9 125618080 [T/G] NM_001354479,NM_001354478,NM_001100588,NM_001354482,NM_018835 RC3H2,RC3H2,RC3H2,RC3H2,RC3H2 EXON Synonymous_I787I,Synonymous_I844I,Synonymous_I844I,Synonymous_I844I,Synonymous_I844I rs7861476 9 125621460 [A/C] NM_001354479,NM_001354478,NM_001100588,NM_001354482,NM_018835 RC3H2,RC3H2,RC3H2,RC3H2,RC3H2 Silent,Silent,Silent,Silent,Silent rs2252419 9 125635605 [A/G] NM_001354479,NM_001354478,NM_001100588,NM_001354482,NM_018835 RC3H2,RC3H2,RC3H2,RC3H2,RC3H2 Silent,Silent,Silent,Silent,Silent rs17220841 9 125645471 [T/C] NM_001354479,NM_001354478,NM_001100588,NM_001354482,NM_018835,NM_001354486 RC3H2,RC3H2,RC3H2,RC3H2,RC3H2,RC3H2 Silent,Silent,Silent,Silent,Silent,Silent rs16912290 9 125649587 [T/C] NM_001354479,NM_001354478,NM_001100588,NM_001354482,NM_018835,NM_001354486 RC3H2,RC3H2,RC3H2,RC3H2,RC3H2,RC3H2 Silent,Silent,Silent,Silent,Silent,Silent rs10818759 9 125652757 [A/G] NM_001354479,NM_001354478,NM_001100588,NM_001354482,NM_018835,NM_001354486 RC3H2,RC3H2,RC3H2,RC3H2,RC3H2,RC3H2 EXON Synonymous_N139N,Synonymous_N139N,Synonymous_N139N,Synonymous_N139N,Synonymous_N139N,Synonymous_N139N rs10985812 9 125663180 [A/G] NM_001354479,NM_001354478,NM_001100588,NM_001354482,NM_018835,NM_001354486 RC3H2,RC3H2,RC3H2,RC3H2,RC3H2,RC3H2 Silent,Silent,Silent,Silent,Silent,Silent rs10985820 9 125671970 [A/G] NM_006626 ZBTB6 EXON Silent rs16912318 9 125672326 [A/G] NM_006626 ZBTB6 EXON Silent rs2239539 9 125675559 [A/G] NM_006626 ZBTB6 EXON Silent rs1147322 9 125675601 [A/G] NM_006626 ZBTB6 EXON Silent rs2241064 9 125680547 [T/C] NM_001304363,NM_020924,NM_001304364 ZBTB26,ZBTB26,ZBTB26 EXON Silent,Silent,Silent rs13299688 9 125680853 [T/G] NM_001304363,NM_020924,NM_001304364 ZBTB26,ZBTB26,ZBTB26 EXON Silent,Silent,Silent rs12683130 9 125684827 [T/C] NM_001304363,NM_020924,NM_001304364 ZBTB26,ZBTB26,ZBTB26 Silent,Silent,Silent rs1868589 9 125694701 [A/C] rs2487387 9 125703274 [A/G] rs10818768 9 125709323 [A/G] NM_012197 RABGAP1 Silent rs12336379 9 125717549 [A/G] NM_012197 RABGAP1 Silent rs10985854 9 125766114 [A/G] NM_012197 RABGAP1 Silent rs34751912 9 125797188 [A/G] NM_012197,NM_005294 RABGAP1,GPR21 EXON Silent,Missense_V115I rs10985869 9 125799927 [T/C] NM_012197 RABGAP1 Silent rs644490 9 125802670 [A/G] NM_012197 RABGAP1 Silent rs2211425 9 125817169 [T/G] NM_012197 RABGAP1 Silent rs700062 9 125828592 [T/C] NM_012197 RABGAP1 Silent rs11793023 9 125847894 [A/G] NM_012197 RABGAP1 Silent rs12005838 9 125851083 [T/G] NM_012197 RABGAP1 Silent rs700084 9 125870322 [A/C] rs700085 9 125870466 [T/C] rs700090 9 125875541 [A/G] NR_026677 MIR600HG EXON Silent rs700091 9 125880828 [A/G] rs700092 9 125880929 [A/G] rs3802486 9 125885490 [T/C] NR_033234,NM_001171137,NM_018387 STRBP,STRBP,STRBP EXON Silent,Silent,Silent rs803731 9 125889495 [T/C] NR_033234,NM_001171137,NM_018387 STRBP,STRBP,STRBP Silent,Silent,Silent rs7032325 9 125917138 [A/G] NR_033234,NM_001171137,NM_018387 STRBP,STRBP,STRBP Silent,Silent,Silent rs803736 9 125920376 [A/G] NR_033234,NM_001171137,NM_018387 STRBP,STRBP,STRBP EXON Silent,Synonymous_G306G,Synonymous_G320G rs803730 9 125963450 [T/C] NR_033234,NM_001171137,NM_018387 STRBP,STRBP,STRBP Silent,Silent,Silent rs7875920 9 125973664 [A/G] NR_033234,NM_001171137,NM_018387 STRBP,STRBP,STRBP Silent,Silent,Silent rs7026688 9 125975397 [A/G] NR_033234,NM_001171137,NM_018387 STRBP,STRBP,STRBP Silent,Silent,Silent rs16926271 9 125982948 [A/C] NR_033234,NM_001171137,NM_018387 STRBP,STRBP,STRBP Silent,Silent,Silent rs2488463 9 125983955 [A/G] NR_033234,NM_001171137,NM_018387 STRBP,STRBP,STRBP Silent,Silent,Silent rs3860155 9 125984527 [T/C] NR_033234,NM_001171137,NM_018387 STRBP,STRBP,STRBP Silent,Silent,Silent rs7870805 9 126013023 [A/G] NR_033234,NM_001171137,NM_018387 STRBP,STRBP,STRBP Silent,Silent,Silent rs6478601 9 126017354 [T/C] NR_033234,NM_001171137,NM_018387 STRBP,STRBP,STRBP Silent,Silent,Silent rs3758333 9 126024561 [T/C] NR_033234,NM_001171137,NM_018387 STRBP,STRBP,STRBP Silent,Silent,Silent rs3739839 9 126031850 [T/C] rs10985931 9 126043304 [A/G] rs10760271 9 126044010 [T/C] rs999655 9 126048349 [T/C] rs868693 9 126049975 [A/C] rs10985938 9 126050038 [T/C] rs12004778 9 126054988 [A/G] rs10818803 9 126056464 [T/C] rs7854591 9 126060193 [T/C] rs10985950 9 126063065 [A/G] rs10985952 9 126063746 [A/G] rs7859203 9 126064590 [A/G] rs10739625 9 126073680 [T/G] rs10739626 9 126073830 [T/G] rs10985963 9 126081738 [T/C] rs7024188 9 126082343 [T/C] rs2416901 9 126083799 [T/C] rs3927757 9 126087359 [A/G] rs7341862 9 126091085 [T/G] rs10760278 9 126094458 [A/G] rs10818810 9 126096522 [A/G] rs3932701 9 126098374 [T/C] rs1891636 9 126099604 [A/G] rs10114139 9 126101008 [A/G] rs7022169 9 126102968 [A/G] rs1971603 9 126106114 [A/G] rs7035562 9 126106142 [A/G] rs1970585 9 126111351 [A/G] rs10985976 9 126113594 [A/G] rs4838051 9 126116865 [T/C] rs1891632 9 126117558 [A/G] rs2491353 9 126123009 [T/C] NM_173689 CRB2 Silent rs2808415 9 126125318 [A/C] NM_173689 CRB2 EXON Missense_T90N rs1105224 9 126127998 [A/G] NM_173689 CRB2 Silent rs7033144 9 126140659 [A/G] NM_173689,NR_104603 CRB2,CRB2 EXON Silent,Silent rs1048616 9 126142233 [A/C] NR_104603,NM_001352965,NM_001352964,NM_020946 CRB2,DENND1A,DENND1A,DENND1A EXON Silent,Silent,Silent,Silent rs4836919 9 126145002 [T/G] NM_001352965,NM_001352964,NM_020946 DENND1A,DENND1A,DENND1A Silent,Silent,Silent rs2797945 9 126150830 [A/G] NM_001352965,NM_001352964,NM_020946 DENND1A,DENND1A,DENND1A Silent,Silent,Silent rs10985997 9 126151949 [T/G] NM_001352965,NM_001352964,NM_020946 DENND1A,DENND1A,DENND1A Silent,Silent,Silent rs1891640 9 126152911 [T/C] NM_001352965,NM_001352964,NM_020946 DENND1A,DENND1A,DENND1A Silent,Silent,Silent rs1891641 9 126153636 [A/G] NM_001352965,NM_001352964,NM_020946 DENND1A,DENND1A,DENND1A Silent,Silent,Silent rs1891642 9 126154776 [A/G] NM_001352965,NM_001352964,NM_020946 DENND1A,DENND1A,DENND1A Silent,Silent,Silent rs4838057 9 126157360 [A/C] NM_001352965,NM_001352964,NM_020946 DENND1A,DENND1A,DENND1A Silent,Silent,Silent rs4466467 9 126162221 [A/G] NM_001352965,NM_001352964,NM_020946 DENND1A,DENND1A,DENND1A Silent,Silent,Silent rs7865976 9 126166739 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16926471 9 126173552 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7048861 9 126177860 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12347955 9 126178928 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7851052 9 126179204 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7026808 9 126179799 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10124048 9 126181097 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10760286 9 126181588 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3924101 9 126187698 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10818820 9 126196204 [T/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7044960 9 126198147 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10739633 9 126202551 [A/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7859831 9 126205754 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3829851 9 126219706 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A EXON Synonymous_D337D,Synonymous_D369D,Synonymous_D369D,Synonymous_D339D,Synonymous_D369D,Silent,Synonymous_D337D,Synonymous_D337D rs10760289 9 126227862 [A/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11999243 9 126231899 [A/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10760290 9 126234414 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2564366 9 126248888 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16926536 9 126251093 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12350892 9 126253077 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2808397 9 126259435 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12001955 9 126260960 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2772208 9 126262932 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2772206 9 126268302 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7863082 9 126272182 [G/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2772215 9 126282999 [A/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10818827 9 126286695 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2772213 9 126287416 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2772212 9 126292586 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7026921 9 126297895 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10513428 9 126304553 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs748994 9 126304695 [T/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17213537 9 126307546 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4836931 9 126309872 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10818831 9 126312791 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6478623 9 126315123 [T/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10986051 9 126319341 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10986053 9 126321003 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4838070 9 126321363 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10119667 9 126324050 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10760291 9 126326884 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7855233 9 126328327 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7048972 9 126333104 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7020626 9 126338482 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7857782 9 126341310 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17286621 9 126343077 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10818846 9 126346105 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10986064 9 126351423 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs733016 9 126361320 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10986070 9 126366529 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7868205 9 126369663 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7037809 9 126383362 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1475527 9 126396606 [A/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10760294 9 126412353 [A/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1366810 9 126415616 [T/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7027523 9 126423340 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17215740 9 126426307 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7028815 9 126435369 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12377595 9 126439100 [T/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6478629 9 126442550 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2078230 9 126447900 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12003386 9 126448659 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10760297 9 126458789 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10818859 9 126459380 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7860055 9 126462707 [T/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7867502 9 126470140 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7864135 9 126472839 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17288360 9 126476410 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4838077 9 126477127 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16926775 9 126481509 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7850520 9 126509806 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12339991 9 126511085 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12002677 9 126519914 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9785285 9 126520068 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A EXON Synonymous_T40T,Synonymous_T72T,Synonymous_T72T,Synonymous_T42T,Synonymous_T72T,Silent,Synonymous_T40T,Synonymous_T40T rs10818868 9 126520497 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17217105 9 126524135 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2479106 9 126525212 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2799463 9 126530988 [A/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1752168 9 126537952 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1752167 9 126540566 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2799465 9 126544609 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2799466 9 126548090 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1752162 9 126551037 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1752166 9 126558843 [T/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12000707 9 126582578 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2768819 9 126593370 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2458490 9 126598435 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7863739 9 126601256 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs549779 9 126613028 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9696009 9 126619233 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs623640 9 126661612 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7021780 9 126664663 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12001870 9 126680050 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12115297 9 126685609 [T/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12000625 9 126686445 [A/C] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3739827 9 126690157 [A/G] NM_001352965,NM_001352964,NM_020946,NM_001352966,NM_024820,NR_148208,NM_001352967,NM_001352968 DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A,DENND1A Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10818894 9 126695770 [A/G] rs10986152 9 126707975 [T/C] rs10760301 9 126710886 [A/G] rs4838084 9 126715275 [A/G] rs10760302 9 126722647 [A/G] rs10986159 9 126722993 [T/C] rs4523363 9 126729111 [T/G] rs10986162 9 126742752 [A/G] rs4836950 9 126749631 [T/C] rs10986172 9 126753312 [T/C] rs1973 9 126756640 [A/C] rs7849890 9 126758163 [A/G] rs4314746 9 126763128 [T/C] rs7046300 9 126767232 [T/C] rs1327291 9 126768048 [T/C] rs969585 9 126768582 [T/C] NR_135129 LOC100505588 EXON Silent rs7867942 9 126771321 [T/C] NR_135129 LOC100505588 Silent rs34250136 9 126772954 [A/G] rs3780680 9 126779494 [T/C] NM_004789 LHX2 Silent rs2075064 9 126783847 [T/C] NM_004789 LHX2 Silent rs4836959 9 126800143 [T/C] rs10986181 9 126801596 [T/C] rs12555707 9 126807459 [T/C] rs12004441 9 126811384 [A/G] rs12002230 9 126813100 [A/G] rs7857883 9 126817862 [T/C] rs7873827 9 126818110 [T/C] rs10986190 9 126818818 [A/G] rs1887342 9 126820948 [A/G] rs12682984 9 126821992 [A/G] rs10121243 9 126823490 [T/C] rs10118027 9 126823752 [T/C] rs10118906 9 126824499 [A/G] rs2025822 9 126824521 [A/G] rs7867375 9 126828640 [T/C] rs7868236 9 126829274 [T/C] rs10760312 9 126831118 [T/C] rs3861868 9 126835484 [A/G] rs4836962 9 126835798 [A/G] rs7046686 9 126848072 [T/C] rs7858267 9 126848249 [T/C] rs10115776 9 126850913 [T/C] rs7858299 9 126855342 [T/G] rs4838113 9 126859995 [A/G] rs7860363 9 126860775 [T/C] rs7863879 9 126861389 [A/G] rs7868364 9 126862478 [T/G] rs7868648 9 126862735 [T/G] rs6478644 9 126862951 [A/G] rs10986211 9 126863146 [T/G] rs7030878 9 126863443 [T/C] rs2182660 9 126871299 [T/C] rs2807610 9 126879182 [A/G] rs1463729 9 126881448 [T/C] rs1576011 9 126885146 [T/C] rs7029319 9 126888086 [T/C] rs2807602 9 126888457 [T/C] rs10118855 9 126889267 [A/G] rs2767755 9 126890847 [A/G] rs2638377 9 126891306 [A/G] rs2807597 9 126891383 [T/C] rs7873448 9 126891946 [A/C] rs2807593 9 126893167 [T/C] rs2807592 9 126893436 [T/G] rs2638381 9 126894348 [A/G] rs2767762 9 126897258 [A/G] rs2478894 9 126905188 [A/G] rs2452174 9 126905298 [T/C] rs10818924 9 126913862 [T/C] rs2767770 9 126914307 [T/G] rs2807584 9 126918033 [A/G] rs7865381 9 126920280 [T/C] rs4838118 9 126935255 [A/C] rs6478649 9 126935364 [A/G] rs1536510 9 126935882 [T/C] rs7860461 9 126946822 [T/C] rs7044794 9 126947706 [T/C] rs4311746 9 126949213 [A/G] rs7042608 9 126951284 [A/G] rs10986266 9 126957987 [T/C] rs2767777 9 126959073 [A/G] rs12003839 9 126959681 [T/G] rs7034837 9 126965119 [T/G] rs1106489 9 126965396 [T/C] rs10986270 9 126967977 [T/C] rs7043914 9 126969243 [A/G] rs10986273 9 126969598 [T/C] rs7021104 9 126970838 [A/C] rs7021109 9 126970903 [A/G] rs4838130 9 126971170 [A/C] rs10760330 9 126974738 [T/C] rs10760331 9 126974767 [T/G] rs10760332 9 126975022 [A/G] rs876452 9 126978958 [A/C] rs10760336 9 126982809 [T/C] rs12339663 9 126983801 [T/C] rs16927289 9 126983984 [T/C] rs953470 9 126984382 [A/G] rs16927294 9 126985334 [A/C] rs6478652 9 126987143 [T/G] rs10818930 9 126991185 [T/G] rs7849959 9 126997079 [T/C] rs7861786 9 127001460 [T/G] rs10986285 9 127005041 [A/G] rs4838140 9 127010114 [T/C] rs7020077 9 127010874 [T/C] rs2065221 9 127020828 [A/G] NM_001166167,NM_014397,NM_001145001,NM_001166168 NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent rs2282085 9 127025040 [A/G] NM_001166167,NM_014397,NM_001145001,NM_001166168 NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent rs2282086 9 127025073 [A/G] NM_001166167,NM_014397,NM_001145001,NM_001166168 NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent rs2282087 9 127025172 [A/G] NM_001166167,NM_014397,NM_001145001,NM_001166168 NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent rs10760344 9 127026282 [T/G] NM_001166167,NM_014397,NM_001145001,NM_001166168 NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent rs12379417 9 127029736 [A/G] NM_001166167,NM_014397,NM_001145001,NM_001166168 NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent rs16927321 9 127031054 [T/C] NM_001166167,NM_014397,NM_001145001,NM_001166168 NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent rs10986296 9 127035761 [T/G] NM_001166167,NM_014397,NM_001145001,NM_001166168 NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent rs7042263 9 127039017 [T/C] NM_001166167,NM_014397,NM_001145001,NM_001166168 NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent rs7872321 9 127052272 [T/C] NM_001166167,NM_014397,NM_001145001,NM_001166168 NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent rs4838153 9 127054184 [T/C] NM_001166167,NM_014397,NM_001145001,NM_001166168 NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent rs944340 9 127060431 [T/C] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2026191 9 127062488 [T/C] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17222478 9 127065836 [A/G] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4838159 9 127069629 [T/G] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7039896 9 127082225 [T/C] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2150237 9 127082375 [A/G] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2274781 9 127083933 [A/G] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10986315 9 127088029 [A/G] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs748741 9 127089775 [A/G] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs912355 9 127090966 [T/C] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4838164 9 127097882 [T/C] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10760354 9 127101924 [T/C] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 EXON Synonymous_L251L,Synonymous_L233L,Synonymous_L267L,Synonymous_L233L,Synonymous_L267L,Synonymous_L233L,Synonymous_L258L rs10818945 9 127112027 [A/G] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2416 9 127113660 [A/G] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12555646 9 127113732 [T/C] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13467 9 127114489 [A/G] NM_001166167,NM_014397,NM_001145001,NM_001166168,NM_001166171,NM_001166170,NM_001166169 NEK6,NEK6,NEK6,NEK6,NEK6,NEK6,NEK6 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1330811 9 127117346 [A/G] NM_002799,NR_027406 PSMB7,LOC100129034 EXON Silent,Silent rs7873147 9 127118386 [T/C] NM_002799,NR_027406 PSMB7,LOC100129034 EXON Silent,Silent rs16927388 9 127119442 [A/G] NM_002799,NR_027406 PSMB7,LOC100129034 EXON Silent,Silent rs10818950 9 127130137 [A/G] NM_002799 PSMB7 Silent rs10818951 9 127131062 [A/G] NM_002799 PSMB7 Silent rs7864941 9 127162888 [A/G] NM_002799 PSMB7 Silent rs12344916 9 127163623 [T/C] NM_002799 PSMB7 Silent rs7027515 9 127173209 [T/C] NM_002799 PSMB7 Silent rs4574 9 127177161 [A/G] NM_002799 PSMB7 EXON Missense_V39A rs10760361 9 127178266 [T/G] rs12343206 9 127184067 [A/G] rs10818964 9 127190340 [A/G] rs4836979 9 127194892 [A/C] rs4838174 9 127195100 [T/C] rs10986339 9 127195873 [A/G] rs1886123 9 127201626 [A/C] rs749147 9 127203382 [A/G] rs11794849 9 127204712 [T/C] rs12683594 9 127205611 [A/G] rs12003217 9 127210541 [A/G] rs7861556 9 127215344 [A/G] rs4838177 9 127218258 [T/C] rs10733669 9 127220133 [A/G] rs16927477 9 127221205 [A/G] rs10760362 9 127223127 [A/G] rs4838181 9 127223212 [A/G] rs7851555 9 127224865 [A/G] rs7859615 9 127226692 [A/G] rs7854446 9 127230864 [A/G] rs10760365 9 127230891 [A/G] rs7852843 9 127233823 [T/C] rs35436654 9 127242082 [A/G] rs10986354 9 127243495 [T/C] rs915034 9 127244955 [A/G] NM_004959 NR5A1 EXON Silent rs7851737 9 127247931 [A/G] NM_004959 NR5A1 Silent rs10114542 9 127256223 [T/C] NM_004959 NR5A1 Silent rs873459 9 127257557 [T/C] NM_004959 NR5A1 Silent rs3758204 9 127261893 [A/G] NM_004959 NR5A1 Silent rs3814134 9 127267689 [A/G] NM_004959 NR5A1 Silent rs16927495 9 127278646 [A/G] rs17225164 9 127280680 [A/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 EXON Silent,Silent,Silent rs3814133 9 127281500 [A/G] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 EXON Silent,Silent,Silent rs13289550 9 127282680 [A/G] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 EXON Silent,Silent,Silent rs12686375 9 127283502 [T/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 EXON Silent,Silent,Silent rs1110026 9 127284751 [A/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 EXON Silent,Silent,Silent rs2297604 9 127289218 [A/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 Silent,Silent,Silent rs10986358 9 127294185 [T/G] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 Silent,Silent,Silent rs12341407 9 127320204 [T/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 Silent,Silent,Silent rs4590537 9 127335754 [T/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 Silent,Silent,Silent rs7032937 9 127338173 [A/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 Silent,Silent,Silent rs4240486 9 127341110 [T/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 Silent,Silent,Silent rs12344513 9 127346281 [T/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 Silent,Silent,Silent rs16927555 9 127402993 [T/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 Silent,Silent,Silent rs10120039 9 127406961 [T/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 Silent,Silent,Silent rs28682517 9 127424770 [A/G] NM_001489,NM_033334,NM_001278546,NR_038975 NR6A1,NR6A1,NR6A1,MIR181A2HG Silent,Silent,Silent,Silent rs6478680 9 127458468 [A/G] NM_001489,NM_033334,NM_001278546,NR_038975 NR6A1,NR6A1,NR6A1,MIR181A2HG Silent,Silent,Silent,Silent rs978694 9 127473874 [T/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 Silent,Silent,Silent rs10760374 9 127495508 [T/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 Silent,Silent,Silent rs7039679 9 127495708 [T/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 Silent,Silent,Silent rs2182694 9 127503410 [T/C] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 Silent,Silent,Silent rs10115723 9 127505979 [A/G] NM_001489,NM_033334,NM_001278546 NR6A1,NR6A1,NR6A1 Silent,Silent,Silent rs721862 9 127535992 [A/G] rs10760376 9 127554070 [A/G] NM_182487 OLFML2A Silent rs750691 9 127562788 [A/G] NM_182487 OLFML2A Silent rs913232 9 127562973 [A/G] NM_182487 OLFML2A Silent rs10818989 9 127564587 [T/G] NM_182487,NM_001282715 OLFML2A,OLFML2A Silent,Silent rs7874348 9 127566378 [A/G] NM_182487,NM_001282715 OLFML2A,OLFML2A EXON Missense_T309A,Missense_T95A rs16927649 9 127570165 [A/G] NM_182487,NM_001282715 OLFML2A,OLFML2A EXON Missense_R425Q,Missense_R211Q rs10986432 9 127570640 [T/C] NM_182487,NM_001282715 OLFML2A,OLFML2A Silent,Silent rs2416952 9 127573167 [T/C] NM_182487,NM_001282715 OLFML2A,OLFML2A EXON Silent,Silent rs4838215 9 127573750 [T/C] NM_182487,NM_001282715 OLFML2A,OLFML2A EXON Silent,Silent rs3739761 9 127575968 [A/G] NM_182487,NM_001282715 OLFML2A,OLFML2A EXON Silent,Silent rs4836995 9 127578625 [T/C] rs1887384 9 127594371 [T/C] rs4838223 9 127597511 [A/G] rs1467676 9 127602518 [A/G] rs12000883 9 127607988 [T/G] rs12552010 9 127612399 [T/C] rs12683929 9 127613385 [T/C] rs3814131 9 127615995 [A/G] NM_001276374,NM_001045476,NM_001276376,NM_001276375 WDR38,WDR38,WDR38,WDR38 Silent,Silent,Silent,Silent rs12375547 9 127616537 [A/G] NM_001276374,NM_001045476,NM_001276376,NM_001276375 WDR38,WDR38,WDR38,WDR38 EXON Synonymous_E41E,Synonymous_E41E,Missense_K10R,Synonymous_E30E rs2274970 9 127618776 [A/G] NM_001276374,NM_001045476,NM_001276376,NM_001276375 WDR38,WDR38,WDR38,WDR38 EXON Missense_H172R,Missense_H172R,Missense_H123R,Missense_H161R rs876663 9 127620141 [A/G] NM_001276374,NM_001045476,NM_001276376,NM_001276375 WDR38,WDR38,WDR38,WDR38 EXON Silent,Silent,Silent,Silent rs2274969 9 127621374 [T/C] NM_007209 RPL35 Silent rs3780591 9 127621644 [A/G] NM_007209 RPL35 Silent rs13299886 9 127631492 [T/G] NM_030978 ARPC5L EXON Silent rs1999589 9 127634429 [T/G] NM_030978 ARPC5L Silent rs671483 9 127642231 [A/G] NM_002077 GOLGA1 EXON Silent rs623096 9 127643168 [T/C] NM_002077 GOLGA1 Silent rs687434 9 127643456 [T/C] NM_002077 GOLGA1 EXON Synonymous_E739E rs2304957 9 127643946 [A/G] NM_002077 GOLGA1 Silent rs17328115 9 127645241 [T/C] NM_002077 GOLGA1 Silent rs13283523 9 127648182 [T/C] NM_002077 GOLGA1 Silent rs16927704 9 127650631 [A/C] NM_002077 GOLGA1 EXON Synonymous_T602T rs634710 9 127661645 [A/G] NM_002077 GOLGA1 EXON Missense_T425M rs583134 9 127674200 [A/C] NM_002077 GOLGA1 EXON Missense_L317V rs9644947 9 127687564 [T/C] NM_002077 GOLGA1 Silent rs3780598 9 127688614 [A/G] NM_002077 GOLGA1 Silent rs13299805 9 127710312 [T/C] NM_001144877,NM_173690 SCAI,SCAI EXON Silent,Silent rs16927789 9 127714146 [T/C] NM_001144877,NM_173690 SCAI,SCAI EXON Silent,Silent rs10986490 9 127720397 [T/C] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs3739764 9 127730457 [T/C] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs2289631 9 127733926 [T/C] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs7045489 9 127736933 [T/C] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs764304 9 127764305 [A/G] NM_001144877,NM_173690 SCAI,SCAI EXON Synonymous_S361S,Synonymous_S384S rs4837005 9 127765978 [T/C] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs1017530 9 127781259 [A/G] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs12684101 9 127784990 [T/C] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs360198 9 127785819 [A/G] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs7857443 9 127785957 [A/G] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs4838242 9 127792230 [A/G] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs2052601 9 127794843 [T/C] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs394750 9 127801065 [T/C] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs608895 9 127809723 [T/C] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs589292 9 127818276 [T/C] NM_001144877,NM_173690 SCAI,SCAI EXON Missense_A37T,Missense_A60T rs603799 9 127820479 [A/G] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs662621 9 127821778 [T/C] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs11789451 9 127825903 [A/G] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs687654 9 127833905 [T/C] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs656322 9 127834277 [A/G] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs643228 9 127834878 [A/G] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs636033 9 127842701 [T/C] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs663153 9 127848785 [A/G] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs10760392 9 127872298 [A/G] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs16927879 9 127887110 [T/C] NM_001144877,NM_173690 SCAI,SCAI Silent,Silent rs1048251 9 127910498 [T/G] NM_001123355,NM_002721,NM_001123369 PPP6C,PPP6C,PPP6C EXON Silent,Silent,Silent rs7019470 9 127913837 [T/C] NM_001123355,NM_002721,NM_001123369 PPP6C,PPP6C,PPP6C Silent,Silent,Silent rs10986614 9 127942240 [T/C] NM_001123355,NM_002721,NM_001123369 PPP6C,PPP6C,PPP6C Silent,Silent,Silent rs10986626 9 127948321 [A/G] NM_001123355,NM_002721,NM_001123369 PPP6C,PPP6C,PPP6C Silent,Silent,Silent rs17337635 9 127958854 [T/C] rs828095 9 127961771 [T/C] rs10986632 9 127962037 [T/C] NR_135145 LOC105376271 Silent rs12684641 9 127962497 [T/C] NR_135145 LOC105376271 Silent rs16927965 9 127975654 [T/C] NM_001174153,NM_001174152,NM_005833 RABEPK,RABEPK,RABEPK EXON Silent,Missense_H73Y,Missense_H73Y rs393721 9 127985775 [A/C] NM_001174153,NM_001174152,NM_005833 RABEPK,RABEPK,RABEPK Silent,Silent,Silent rs12003827 9 127990094 [T/C] NM_001174153,NM_001174152,NM_005833 RABEPK,RABEPK,RABEPK Silent,Silent,Silent rs10986660 9 127994103 [A/G] NM_001174153,NM_001174152,NM_005833 RABEPK,RABEPK,RABEPK Silent,Silent,Silent rs7869876 9 127994564 [A/G] NM_001174153,NM_001174152,NM_005833 RABEPK,RABEPK,RABEPK Silent,Silent,Silent rs599063 9 127996046 [A/G] NM_001174153,NM_001174152,NM_005833 RABEPK,RABEPK,RABEPK EXON Synonymous_P251P,Synonymous_P302P,Synonymous_P302P rs938729 9 127996472 [A/G] rs12009 9 127997303 [A/G] NM_005347 HSPA5 EXON Silent rs7922 9 127998733 [A/G] NM_005347 HSPA5 EXON Silent rs10986663 9 127999501 [A/G] NM_005347 HSPA5 Silent rs34786778 9 127999973 [T/C] NM_005347 HSPA5 Silent rs17253433 9 128002626 [A/G] NM_005347 HSPA5 Silent rs391957 9 128004024 [T/C] rs662637 9 128021166 [T/C] rs372225 9 128024049 [A/G] rs359594 9 128035341 [T/C] NM_001354298,NM_001354300,NM_001282679,NM_001354296,NM_001354297,NM_001330777,NM_015635,NM_001354301,NM_001354293,NM_001354299,NM_001354294,NM_001282681,NR_148733,NM_001354295,NM_001282680,NR_148732,NM_001330778 GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10986694 9 128064673 [T/G] NM_001354298,NM_001354300,NM_001282679,NM_001354296,NM_001354297,NM_001330777,NM_015635,NM_001354301,NM_001354293,NM_001354299,NM_001354294,NM_001282681,NR_148733,NM_001354295,NM_001282680,NR_148732,NM_001330778 GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1 EXON Synonymous_T199T,Synonymous_T199T,Synonymous_T199T,Synonymous_T199T,Synonymous_T199T,Synonymous_T199T,Synonymous_T199T,Synonymous_T199T,Synonymous_T199T,Synonymous_T199T,Synonymous_T199T,Synonymous_T199T,Silent,Synonymous_T199T,Synonymous_T199T,Silent,Synonymous_T199T rs13294021 9 128068388 [A/G] NM_001354298,NM_001354300,NM_001282679,NM_001354296,NM_001354297,NM_001330777,NM_015635,NM_001354301,NM_001354293,NM_001354299,NM_001354294,NM_001282681,NR_148733,NM_001354295,NM_001282680,NR_148732,NM_001330778 GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs432757 9 128074807 [T/C] NM_001354298,NM_001354300,NM_001282679,NM_001354296,NM_001354297,NM_001330777,NM_015635,NM_001354301,NM_001354299,NM_001354294,NM_001282681,NR_148733,NM_001354295,NM_001282680,NR_148732,NM_001330778 GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1 EXON Synonymous_I506I,Synonymous_I506I,Synonymous_I506I,Synonymous_I506I,Synonymous_I506I,Synonymous_I506I,Synonymous_I506I,Synonymous_I506I,Synonymous_I506I,Synonymous_I506I,Synonymous_I506I,Silent,Synonymous_I506I,Synonymous_I506I,Silent,Synonymous_I506I rs12552401 9 128097490 [A/G] NM_001354298,NM_001354300,NM_001282679,NM_001354296,NM_001354297,NM_001330777,NM_015635,NM_001354301,NM_001354299,NM_001354294,NM_001282681,NR_148733,NM_001354295,NM_001282680,NR_148732,NM_001330778 GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1 EXON Missense_H823R,Silent,Silent,Silent,Silent,Silent,Missense_H823R,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12351757 9 128099037 [T/C] NM_001354298,NM_001354300,NM_001282679,NM_001354296,NM_001354297,NM_001330777,NM_015635,NM_001354301,NM_001354299,NM_001354294,NM_001282681,NR_148733,NM_001354295,NM_001282680,NR_148732,NM_001330778 GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10114684 9 128102865 [T/C] NM_001354298,NM_001354300,NM_001282679,NM_001354296,NM_001354297,NM_001330777,NM_015635,NM_001354301,NM_001354299,NM_001354294,NM_001282681,NR_148733,NM_001354295,NM_001282680,NR_148732,NM_001330778 GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11794365 9 128103476 [T/C] NM_001354298,NM_001354300,NM_001282679,NM_001354296,NM_001354297,NM_001330777,NM_015635,NM_001354301,NM_001354299,NM_001354294,NM_001282681,NR_148733,NM_001354295,NM_001282680,NR_148732,NM_001330778 GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1 EXON Synonymous_S993S,Synonymous_S945S,Synonymous_S966S,Synonymous_S966S,Synonymous_S945S,Synonymous_S945S,Synonymous_S993S,Synonymous_S966S,Synonymous_S966S,Synonymous_S966S,Synonymous_S945S,Silent,Synonymous_S966S,Synonymous_S966S,Silent,Synonymous_S966S rs828290 9 128104105 [A/C] NM_001354298,NM_001354300,NM_001282679,NM_001354296,NM_001354297,NM_001330777,NM_015635,NM_001354301,NM_001354299,NM_001354294,NM_001282681,NR_148733,NM_001354295,NM_001282680,NR_148732,NM_001330778 GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16928102 9 128107243 [A/G] NM_001354298,NM_001354300,NM_001282679,NM_001354296,NM_001354297,NM_001330777,NM_015635,NM_001354301,NM_001354299,NM_001354294,NM_001282681,NR_148733,NM_001354295,NM_001282680,NR_148732,NM_001330778 GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs937482 9 128116817 [A/G] NM_001354298,NM_001354300,NM_001282679,NM_001354296,NM_001354297,NM_001330777,NM_015635,NM_001354301,NM_001354299,NM_001354294,NM_001282681,NR_148733,NM_001354295,NM_001282680,NR_148732,NM_001330778 GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2841334 9 128122320 [A/G] NM_001354298,NM_001354300,NM_001282679,NM_001354296,NM_001354297,NM_001330777,NM_015635,NM_001354301,NM_001354299,NM_001354294,NM_001282681,NR_148733,NM_001354295,NM_001282680,NR_148732,NM_001330778 GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10986721 9 128124309 [T/C] NM_001354298,NM_001354300,NM_001282679,NM_001354296,NM_001354297,NM_001330777,NM_015635,NM_001354301,NM_001354299,NM_001354294,NM_001282681,NR_148733,NM_001354295,NM_001282680,NR_148732,NM_001330778 GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10986723 9 128126382 [A/G] NM_001354298,NM_001354300,NM_001282679,NM_001354296,NM_001354297,NM_001330777,NM_015635,NM_001354301,NM_001354299,NM_001354294,NM_001282681,NR_148733,NM_001354295,NM_001282680,NR_148732,NM_001330778 GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1,GAPVD1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10819047 9 128127412 [A/G] NM_001330777,NM_001282680,NM_001330778 GAPVD1,GAPVD1,GAPVD1 EXON Silent,Silent,Silent rs10760397 9 128133207 [T/C] rs1463837 9 128135215 [T/C] rs10435893 9 128136339 [A/G] rs10986727 9 128137615 [A/G] rs6478703 9 128141348 [A/G] rs10986735 9 128148391 [T/C] rs4838261 9 128149249 [T/C] rs2648315 9 128150784 [T/C] rs10986738 9 128153831 [A/G] rs2819625 9 128156648 [A/G] rs10986739 9 128161614 [A/C] rs12002063 9 128175143 [A/G] rs2648327 9 128180751 [A/G] rs3126226 9 128184480 [A/G] rs3122931 9 128185330 [T/C] rs1250505 9 128193456 [T/G] rs16928181 9 128196221 [A/G] rs6478704 9 128198422 [A/C] rs907500 9 128207717 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent rs10115550 9 128208234 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent rs10760398 9 128208927 [A/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent rs7857424 9 128224030 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent rs7018948 9 128233506 [A/G] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent rs7038668 9 128239920 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent rs13291556 9 128240922 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent rs7022356 9 128260962 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent rs7044663 9 128268263 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent rs10986783 9 128277742 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent rs4838268 9 128280315 [T/G] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent rs7861903 9 128282914 [A/G] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent rs700115 9 128291664 [A/G] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs522894 9 128299605 [A/G] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs17257143 9 128303394 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs10114882 9 128303425 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs829179 9 128316645 [A/G] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs7041061 9 128319624 [A/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs16928300 9 128328386 [A/G] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs512445 9 128329179 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs545900 9 128341278 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs481345 9 128358344 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs7864945 9 128373469 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs16928344 9 128396113 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs4838278 9 128403509 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs1250733 9 128406040 [A/G] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs631287 9 128412676 [A/G] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs16928370 9 128414522 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs871391 9 128420381 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs2416967 9 128440014 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs7031865 9 128448090 [T/G] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs7863341 9 128449085 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs11793676 9 128453605 [T/C] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs7028811 9 128466521 [A/G] NM_001006617,NM_001006619,NM_024117,NM_001006621,NM_001006620,NM_001006618 MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1,MAPKAP1 Silent,Silent,Silent,Silent,Silent,Silent rs10118570 9 128476464 [A/G] rs10986857 9 128488794 [A/G] rs12341976 9 128546359 [T/G] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs12235282 9 128554563 [A/G] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs10986936 9 128569777 [A/G] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs10986949 9 128579279 [T/C] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs7857215 9 128582560 [A/G] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs9644950 9 128599281 [T/G] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs13295318 9 128610269 [T/C] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs11789020 9 128616376 [A/G] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs12347338 9 128641097 [T/G] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs1411353 9 128643415 [T/C] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs1411351 9 128664410 [T/C] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs2026134 9 128680148 [T/C] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs2026133 9 128680409 [T/G] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs10819087 9 128695180 [A/G] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs10513456 9 128719849 [A/G] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 Silent,Silent,Silent,Silent,Silent rs11792585 9 128728459 [A/G] NR_024123,NM_001330782,NM_006195,NR_024122,NM_001134778 PBX3,PBX3,PBX3,PBX3,PBX3 EXON Silent,Silent,Silent,Silent,Silent rs4837024 9 128739400 [T/C] rs7045552 9 128739508 [T/C] rs10987069 9 128740896 [A/G] rs7868608 9 128746044 [A/G] rs10987080 9 128748401 [A/G] rs2149990 9 128754234 [T/C] rs4240495 9 128755979 [T/C] rs10217522 9 128756075 [T/C] rs4837027 9 128756484 [T/C] rs10987095 9 128765264 [T/C] rs7874953 9 128765362 [A/G] rs10987096 9 128766193 [A/G] rs10819101 9 128768663 [T/C] rs13291454 9 128773388 [A/G] rs17268583 9 128779162 [T/C] rs13290614 9 128780293 [T/C] rs13290624 9 128780313 [T/C] rs10987107 9 128783188 [T/G] rs7031853 9 128783981 [T/C] rs4838311 9 128788342 [T/C] rs9299306 9 128788957 [A/C] rs10819102 9 128791490 [T/C] rs10819103 9 128791503 [T/C] rs7029545 9 128792334 [T/C] rs4838313 9 128792958 [A/G] rs10987111 9 128792979 [T/C] rs2416993 9 128797551 [T/C] rs2019199 9 128798584 [T/C] rs1558836 9 128800424 [A/G] rs11787905 9 128803263 [T/C] rs4837031 9 128805768 [A/G] rs10819104 9 128806385 [A/C] rs2098440 9 128807593 [T/C] rs16928613 9 128808825 [T/C] rs4837032 9 128809179 [A/G] rs7861741 9 128810469 [T/C] rs10217721 9 128810846 [T/C] rs10987119 9 128812194 [T/C] rs929673 9 128816587 [A/G] rs888236 9 128817516 [T/C] rs7030500 9 128818908 [T/G] rs4838318 9 128822026 [A/C] rs888231 9 128826791 [T/G] rs7020350 9 128827305 [T/C] rs10987122 9 128828716 [A/G] rs4838320 9 128831097 [T/C] rs10987129 9 128834294 [A/C] rs999566 9 128835802 [T/C] rs4838322 9 128836559 [A/G] rs4837036 9 128842857 [T/C] rs10819112 9 128843485 [A/G] rs13295982 9 128844657 [T/G] rs7468639 9 128844997 [A/G] rs16928653 9 128845089 [T/C] rs10819113 9 128845092 [A/G] rs17269441 9 128846395 [A/G] rs10987141 9 128847015 [T/G] rs13289050 9 128847170 [T/C] rs1420771 9 128849488 [A/C] rs10987149 9 128857851 [A/G] rs10819120 9 128858530 [A/G] rs12552226 9 128858795 [A/C] rs2041944 9 128866262 [A/G] rs2111362 9 128866390 [T/G] rs10819122 9 128869210 [A/G] rs16928677 9 128875526 [T/C] rs6478724 9 128876516 [A/G] rs10987154 9 128877531 [T/C] rs2417001 9 128879579 [A/G] rs4595229 9 128879934 [A/G] rs888234 9 128880042 [A/G] rs4838340 9 128880225 [A/G] rs7871394 9 128880277 [A/G] rs2417002 9 128881745 [T/C] rs7858074 9 128883849 [A/G] rs7046411 9 128893045 [A/C] rs10217645 9 128893372 [A/G] rs1156715 9 128900528 [A/G] rs10760416 9 128905129 [T/C] rs1055352 9 128910419 [A/G] rs882061 9 128911346 [T/C] rs10122194 9 128913654 [T/C] rs4838353 9 128920470 [T/C] rs1477148 9 128921892 [A/G] rs10125891 9 128921921 [T/C] rs4837043 9 128922682 [A/G] rs7019762 9 128923809 [T/C] rs888225 9 128926091 [A/C] rs888224 9 128926239 [A/G] rs7018610 9 128926989 [T/C] rs10987177 9 128928087 [A/C] rs13290757 9 128928438 [T/C] rs13340654 9 128928919 [T/G] rs1536960 9 128937675 [T/C] rs2809443 9 128947475 [T/G] rs11790107 9 128952700 [T/G] rs2773379 9 128953978 [T/C] rs7039848 9 128954507 [T/G] rs7034019 9 128965556 [T/G] rs10819136 9 128966109 [A/G] rs10987198 9 128968531 [T/G] rs10987199 9 128968987 [T/C] rs2417008 9 128970219 [A/G] rs10987202 9 128970806 [A/G] rs7021461 9 128972210 [A/C] rs2094763 9 128975311 [A/G] rs10987204 9 128976978 [A/G] rs2065183 9 128978468 [T/C] rs2150010 9 128982650 [T/C] rs2809423 9 128983878 [A/G] rs2809426 9 128986041 [A/G] rs1106477 9 128987079 [T/C] rs10987215 9 128987905 [T/C] rs12005670 9 128990287 [A/G] rs2773390 9 128990760 [A/C] rs16928802 9 128991622 [T/C] rs1537010 9 128993470 [A/G] rs16928804 9 128993952 [A/C] rs2039200 9 128994668 [A/G] rs2809428 9 129001029 [A/G] rs17272567 9 129001487 [T/C] rs7019665 9 129011462 [A/G] rs10987225 9 129018625 [A/G] rs10760423 9 129019248 [A/G] rs2491650 9 129029139 [A/G] rs16928843 9 129030818 [A/G] rs12686700 9 129042345 [A/G] rs951214 9 129042699 [A/C] rs4836535 9 129046512 [T/G] rs1556218 9 129046730 [T/C] rs2026808 9 129049692 [T/C] rs1536959 9 129053531 [A/G] rs12001707 9 129053648 [A/G] rs1317309 9 129056597 [A/C] rs4837051 9 129057800 [T/C] rs10987235 9 129058255 [A/G] rs12004434 9 129058924 [T/C] rs7466244 9 129059870 [A/G] rs944212 9 129060075 [T/G] rs539215 9 129061512 [A/C] rs10116388 9 129061773 [T/G] rs1230760 9 129062836 [T/G] rs2015843 9 129064598 [A/C] rs504184 9 129074984 [T/C] rs561769 9 129075914 [T/C] rs4837056 9 129076709 [A/G] rs10987243 9 129077606 [T/C] rs10987246 9 129079854 [A/G] rs562800 9 129087114 [A/C] rs10739669 9 129088202 [A/G] rs35791166 9 129088509 [A/G] rs568240 9 129089985 [A/G] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs10819147 9 129096474 [T/C] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs554317 9 129102381 [T/C] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs1888156 9 129102840 [A/G] NM_001011703,NM_033446 MVB12B,MVB12B EXON Synonymous_T45T,Synonymous_T45T rs12554306 9 129105723 [A/G] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs568565 9 129115381 [T/C] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs1360289 9 129115717 [T/C] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs505442 9 129117662 [T/C] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs10987253 9 129120430 [A/C] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs548403 9 129121098 [A/G] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs10987261 9 129139361 [A/C] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs10124379 9 129141450 [T/C] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs2286889 9 129143435 [A/G] NM_001011703,NM_033446 MVB12B,MVB12B EXON Synonymous_S99S,Synonymous_S99S rs917776 9 129146344 [T/G] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs12343356 9 129149327 [T/C] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs4837074 9 129156437 [T/G] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs10491513 9 129157541 [A/G] NM_001011703,NM_033446 MVB12B,MVB12B Silent,Silent rs7027883 9 129158091 [T/C] NM_001011703,NM_033446 MVB12B,MVB12B EXON Silent,Silent rs11793111 9 129158371 [A/G] NM_001011703,NM_033446 MVB12B,MVB12B EXON Silent,Silent rs2241011 9 129159558 [T/G] NM_001011703,NM_033446 MVB12B,MVB12B EXON Silent,Silent rs2052156 9 129159883 [A/G] NM_001011703,NM_033446 MVB12B,MVB12B EXON Silent,Silent rs4837076 9 129165182 [A/G] NM_033446 MVB12B Silent rs10760430 9 129166088 [A/G] NM_033446 MVB12B Silent rs10987269 9 129170242 [A/G] NM_033446,NR_045006 MVB12B,NRON EXON Silent,Silent rs887659 9 129184309 [A/G] NM_033446 MVB12B Silent rs10760434 9 129192627 [A/C] NM_033446 MVB12B Silent rs758970 9 129194773 [A/G] NM_033446 MVB12B Silent rs2041543 9 129197579 [T/C] NM_033446 MVB12B Silent rs10987278 9 129204547 [T/C] NM_033446 MVB12B Silent rs10987285 9 129215558 [A/G] NM_033446 MVB12B Silent rs13287948 9 129216848 [A/G] NM_033446 MVB12B Silent rs10760437 9 129221756 [T/G] NM_033446 MVB12B Silent rs12683116 9 129229878 [A/G] NM_033446 MVB12B Silent rs12376387 9 129230541 [T/C] NM_033446 MVB12B Silent rs1468675 9 129231957 [T/C] NM_033446 MVB12B Silent rs887655 9 129232379 [T/C] NM_033446 MVB12B Silent rs887653 9 129234311 [A/G] NM_033446 MVB12B Silent rs7047946 9 129236624 [A/G] NM_033446 MVB12B Silent rs4837090 9 129237931 [T/C] NM_033446 MVB12B Silent rs10819166 9 129241490 [A/G] NM_033446 MVB12B Silent rs10733677 9 129242209 [T/C] NM_033446 MVB12B Silent rs13297792 9 129242770 [A/G] NM_033446 MVB12B Silent rs12686564 9 129243218 [T/C] NM_033446 MVB12B Silent rs11787581 9 129244060 [T/C] NM_033446 MVB12B Silent rs2286886 9 129246177 [T/C] NM_033446 MVB12B Silent rs1890008 9 129249570 [T/C] NM_033446 MVB12B Silent rs10819170 9 129252874 [A/G] NM_033446 MVB12B Silent rs2417022 9 129253461 [A/G] NM_033446 MVB12B Silent rs1548788 9 129258837 [A/G] NM_033446 MVB12B Silent rs10987305 9 129260257 [A/G] NM_033446 MVB12B Silent rs7850531 9 129261329 [T/C] NM_033446 MVB12B Silent rs3814127 9 129265742 [A/G] NM_033446 MVB12B EXON Silent rs10819174 9 129268065 [T/C] NM_033446 MVB12B EXON Silent rs10739677 9 129268204 [T/G] NM_033446 MVB12B EXON Silent rs16929088 9 129269846 [T/C] rs929561 9 129270009 [T/C] rs10987313 9 129270114 [A/G] rs7042444 9 129270986 [A/G] rs4837096 9 129276052 [T/C] rs13295594 9 129284289 [T/C] rs12001841 9 129284495 [T/C] rs10987324 9 129286085 [A/G] rs10739679 9 129294471 [A/G] rs7860558 9 129300073 [T/C] rs10819180 9 129302884 [T/C] rs10987336 9 129303487 [A/G] rs7864931 9 129310354 [A/G] rs4557799 9 129310775 [T/C] rs10987343 9 129311431 [A/G] rs945683 9 129311651 [A/G] rs2417025 9 129312129 [A/G] rs7875553 9 129316001 [T/C] rs10987351 9 129317565 [A/G] rs10819182 9 129320566 [A/G] rs3861869 9 129323601 [A/G] rs3861870 9 129324021 [A/G] rs13301795 9 129324974 [A/G] rs7021240 9 129325376 [A/C] rs13287122 9 129325783 [A/G] rs10987360 9 129326937 [A/G] rs10987361 9 129327674 [A/C] rs7856616 9 129332556 [T/C] rs3904195 9 129334700 [A/G] rs7868155 9 129340692 [A/G] rs7871965 9 129341524 [T/C] rs7855272 9 129344763 [A/G] rs10115026 9 129345624 [A/G] rs12682999 9 129349127 [T/C] rs7040946 9 129361764 [T/C] rs10733680 9 129361955 [A/G] rs2235056 9 129377235 [T/C] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs4455975 9 129383199 [A/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs4240414 9 129389710 [T/C] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs3829849 9 129390800 [T/C] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs10760444 9 129396434 [A/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs10448285 9 129397014 [T/C] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs12377679 9 129397755 [A/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs7858338 9 129406644 [T/C] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs11793373 9 129407543 [A/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs10819190 9 129408513 [A/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs6478750 9 129409198 [T/C] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs10987386 9 129416317 [T/C] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs7874916 9 129418360 [A/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs3902840 9 129419025 [A/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs10819195 9 129422783 [A/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs4322101 9 129428677 [A/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs16929210 9 129429754 [T/C] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs7030919 9 129438872 [A/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs13285134 9 129452204 [T/C] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B Silent,Silent,Silent rs2277158 9 129453229 [A/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B EXON Synonymous_E147E,Synonymous_E147E,Synonymous_E147E rs10115373 9 129458757 [A/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B EXON Silent,Silent,Silent rs10987414 9 129459478 [T/C] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B EXON Silent,Silent,Silent rs10760450 9 129459628 [T/C] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B EXON Silent,Silent,Silent rs10733682 9 129460914 [A/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B EXON Silent,Silent,Silent rs3861878 9 129461912 [A/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B EXON Silent,Silent,Silent rs10987417 9 129462501 [T/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B EXON Silent,Silent,Silent rs10987421 9 129462611 [T/G] NM_002316,NM_001174146,NM_001174147 LMX1B,LMX1B,LMX1B EXON Silent,Silent,Silent rs3906146 9 129463613 [T/C] rs867559 9 129465325 [A/G] rs13287548 9 129466456 [T/C] rs7870976 9 129471897 [A/C] rs7041217 9 129477410 [T/C] rs9792682 9 129481232 [T/G] rs3850586 9 129486982 [T/C] rs2417034 9 129490258 [A/G] rs10125011 9 129506906 [T/C] rs10819218 9 129510823 [T/C] rs10114029 9 129512251 [A/G] rs913716 9 129512633 [T/C] rs1005918 9 129513586 [T/G] rs10987468 9 129515955 [T/C] rs7026747 9 129523907 [T/C] rs7858544 9 129524753 [T/C] rs12352423 9 129540970 [A/G] rs6478755 9 129544443 [T/C] rs10987481 9 129550903 [T/C] rs2417038 9 129551466 [A/G] rs7036823 9 129552881 [A/C] rs10987487 9 129561308 [T/C] rs873836 9 129567615 [T/C] NM_014007,NM_001135776 ZBTB43,ZBTB43 Silent,Silent rs873837 9 129567832 [A/C] NM_014007,NM_001135776 ZBTB43,ZBTB43 Silent,Silent rs1329407 9 129571638 [T/G] NM_014007,NM_001135776 ZBTB43,ZBTB43 Silent,Silent rs10987488 9 129575061 [A/G] NM_014007,NM_001135776 ZBTB43,ZBTB43 Silent,Silent rs2900252 9 129577902 [T/C] NM_014007,NM_001135776 ZBTB43,ZBTB43 Silent,Silent rs3118994 9 129595895 [T/C] NM_014007,NM_001135776 ZBTB43,ZBTB43 EXON Synonymous_T369T,Synonymous_T369T rs12683887 9 129597065 [T/C] NM_014007,NM_001135776 ZBTB43,ZBTB43 EXON Silent,Silent rs999564 9 129600571 [T/C] rs10760457 9 129601835 [T/C] rs7021197 9 129602067 [A/C] rs6478760 9 129602746 [A/G] rs7032601 9 129609815 [A/G] rs7035535 9 129613696 [T/C] rs10733686 9 129616938 [A/G] rs1463810 9 129617253 [T/C] rs10987505 9 129619875 [A/G] rs7030157 9 129625226 [T/C] NM_001099270 ZBTB34 Silent rs10819242 9 129630126 [T/C] NM_001099270 ZBTB34 Silent rs10819243 9 129633328 [A/G] NM_001099270 ZBTB34 Silent rs4291364 9 129638142 [A/G] NM_001099270 ZBTB34 Silent rs10819246 9 129643296 [T/G] NM_001099270 ZBTB34 EXON Silent rs12178 9 129646775 [A/G] NM_001099270 ZBTB34 EXON Silent rs571606 9 129647028 [A/G] NM_001099270 ZBTB34 EXON Silent rs12235895 9 129648531 [A/G] rs3120029 9 129649356 [A/G] rs671261 9 129659918 [T/C] rs4836555 9 129670028 [A/G] rs3118831 9 129676891 [A/G] rs581444 9 129686561 [A/C] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs537717 9 129705957 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs518116 9 129715736 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2031852 9 129755509 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11789307 9 129762597 [T/C] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10739688 9 129772495 [T/C] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10115627 9 129777653 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7019291 9 129789615 [A/C] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11793604 9 129791911 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7864425 9 129807559 [T/C] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11788993 9 129826261 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7031192 9 129827789 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2789513 9 129828036 [T/C] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2789514 9 129833029 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10122289 9 129844976 [T/C] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4837129 9 129848136 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs8838 9 129849880 [T/C] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728,NM_012098 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,ANGPTL2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12554810 9 129850075 [T/C] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728,NM_012098 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,ANGPTL2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7023554 9 129850528 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728,NM_012098 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,ANGPTL2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2275405 9 129851194 [T/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728,NM_012098 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,ANGPTL2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2297866 9 129854199 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728,NM_012098 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,ANGPTL2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Synonymous_D344D rs13298677 9 129862996 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728,NM_012098 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,ANGPTL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1768374 9 129877979 [T/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728,NM_012098 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,ANGPTL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7045790 9 129883806 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728,NM_012098 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,ANGPTL2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1556888 9 129887008 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12551115 9 129906656 [A/C] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1109042 9 129912506 [T/C] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12115785 9 129917249 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11789486 9 129921983 [A/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3739555 9 129940416 [T/G] NM_014636,NM_001190730,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10819272 9 129954334 [T/C] NM_014636,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2779711 9 129956147 [A/G] NM_014636,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7030134 9 129958148 [A/G] NM_014636,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10987574 9 129968138 [A/G] NM_014636,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2779710 9 129975605 [A/G] NM_014636,NM_001322320,NM_001190729,NM_001322322,NM_001322325,NM_001322324,NM_001322323,NM_001322321,NM_001190728 RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2779708 9 129979725 [A/G] NM_014636,NM_001322322,NM_001322324,NM_001322321 RALGPS1,RALGPS1,RALGPS1,RALGPS1 Silent,Silent,Silent,Silent rs7040276 9 129982879 [A/G] NM_014636,NM_001322322,NM_001322324,NM_001322321 RALGPS1,RALGPS1,RALGPS1,RALGPS1 EXON Silent,Silent,Silent,Silent rs3739553 9 129984107 [A/G] NM_014636,NM_001322322,NM_001322324,NM_001322321 RALGPS1,RALGPS1,RALGPS1,RALGPS1 EXON Silent,Silent,Silent,Silent rs1058266 9 129985108 [A/G] NM_014636,NM_001322322,NM_001322324,NM_001322321 RALGPS1,RALGPS1,RALGPS1,RALGPS1 EXON Silent,Silent,Silent,Silent rs2812289 9 129992084 [A/C] rs7046445 9 130002139 [G/C] rs12348504 9 130014390 [A/G] rs2779732 9 130022540 [T/C] rs4075654 9 130024423 [T/G] rs12343725 9 130026409 [T/C] NM_001286779 GARNL3 Silent rs16929724 9 130026960 [A/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 EXON Silent,Silent,Silent rs10513479 9 130034215 [A/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs10513480 9 130039406 [T/C] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs7874931 9 130044420 [A/C] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs10987587 9 130046379 [T/C] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs16929752 9 130052614 [A/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs2779727 9 130053105 [T/C] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs2812273 9 130055785 [T/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs2812283 9 130064972 [T/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs10987595 9 130089323 [T/C] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs10987596 9 130094526 [T/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs3802370 9 130100305 [A/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs10987600 9 130105618 [A/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs7863063 9 130106778 [T/C] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs4130590 9 130107964 [A/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs7029536 9 130110411 [T/C] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs6478770 9 130112231 [T/C] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs4837142 9 130114364 [T/C] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs3934537 9 130116358 [A/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs4454390 9 130123425 [A/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs10987613 9 130125184 [A/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs10819279 9 130128056 [T/C] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs10987618 9 130131526 [A/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs7048256 9 130132392 [A/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs3935681 9 130132870 [A/C] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs10819283 9 130143113 [A/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs3824415 9 130145624 [A/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs10819284 9 130147979 [A/G] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs16929827 9 130148477 [T/C] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs10987630 9 130152522 [T/C] NM_001286779,NM_032293,NR_104591 GARNL3,GARNL3,GARNL3 Silent,Silent,Silent rs3808835 9 130159333 [T/G] rs1138740 9 130165995 [T/C] NM_001271711,NM_014580,NM_001271712,NR_073416 SLC2A8,SLC2A8,SLC2A8,SLC2A8 EXON Synonymous_G260G,Synonymous_G260G,Synonymous_G97G,Silent rs3824414 9 130166857 [T/C] NM_001271711,NM_014580,NM_001271712,NR_073416 SLC2A8,SLC2A8,SLC2A8,SLC2A8 Silent,Silent,Silent,Silent rs3802364 9 130166957 [T/C] NM_001271711,NM_014580,NM_001271712,NR_073416 SLC2A8,SLC2A8,SLC2A8,SLC2A8 Silent,Silent,Silent,Silent rs3824413 9 130167390 [T/C] NM_001271711,NM_014580,NM_001271712,NR_073416 SLC2A8,SLC2A8,SLC2A8,SLC2A8 Silent,Silent,Silent,Silent rs10987637 9 130168326 [T/C] NM_001271711,NM_014580,NM_001271712,NR_073416 SLC2A8,SLC2A8,SLC2A8,SLC2A8 Silent,Silent,Silent,Silent rs10987639 9 130172485 [A/G] rs10819291 9 130186700 [T/C] NM_001286697,NM_001322260,NM_001286696,NM_001286698,NM_007135 ZNF79,ZNF79,ZNF79,ZNF79,ZNF79 EXON Silent,Silent,Silent,Silent,Silent rs13292096 9 130191186 [T/C] NM_001286697,NM_001322260,NM_001286696,NM_001286698,NM_007135 ZNF79,ZNF79,ZNF79,ZNF79,ZNF79 EXON Missense_T7I,Missense_T7I,Missense_T7I,Silent,Missense_T31I rs10819293 9 130196674 [A/C] NM_001286697,NM_001322260,NM_001286696,NM_001286698,NM_007135 ZNF79,ZNF79,ZNF79,ZNF79,ZNF79 Silent,Silent,Silent,Silent,Silent rs4504745 9 130197414 [A/G] NM_001286697,NM_001322260,NM_001286696,NM_001286698,NM_007135 ZNF79,ZNF79,ZNF79,ZNF79,ZNF79 EXON Missense_R27G,Missense_R27G,Missense_R27G,Silent,Missense_R51G rs7869023 9 130201678 [A/G] NM_001286697,NM_001322260,NM_001286696,NM_001286698,NM_007135 ZNF79,ZNF79,ZNF79,ZNF79,ZNF79 Silent,Silent,Silent,Silent,Silent rs2491101 9 130215249 [T/C] NM_001005373,NM_001190723,NM_138361,NM_001005374 LRSAM1,LRSAM1,LRSAM1,LRSAM1 Silent,Silent,Silent,Silent rs2243906 9 130219669 [T/C] NM_001005373,NM_001190723,NM_138361,NM_001005374 LRSAM1,LRSAM1,LRSAM1,LRSAM1 EXON Synonymous_I83I,Synonymous_I83I,Synonymous_I83I,Synonymous_I83I rs2243767 9 130221388 [T/C] NM_001005373,NM_001190723,NM_138361,NM_001005374 LRSAM1,LRSAM1,LRSAM1,LRSAM1 Silent,Silent,Silent,Silent rs10819295 9 130235053 [A/G] NM_001005373,NM_001190723,NM_138361,NM_001005374 LRSAM1,LRSAM1,LRSAM1,LRSAM1 Silent,Silent,Silent,Silent rs1539569 9 130241822 [T/C] NM_001005373,NM_001190723,NM_138361,NM_001005374 LRSAM1,LRSAM1,LRSAM1,LRSAM1 Silent,Silent,Silent,Silent rs1539567 9 130242166 [A/G] NM_001005373,NM_001190723,NM_138361,NM_001005374 LRSAM1,LRSAM1,LRSAM1,LRSAM1 EXON Missense_N318D,Missense_N318D,Missense_N318D,Missense_N318D rs2246270 9 130246564 [T/C] NM_001005373,NM_001190723,NM_138361,NM_001005374 LRSAM1,LRSAM1,LRSAM1,LRSAM1 Silent,Silent,Silent,Silent rs2245389 9 130266566 [A/G] rs2265814 9 130274290 [T/G] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs2254868 9 130280589 [A/G] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs2254622 9 130282839 [T/G] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs1891732 9 130286428 [A/G] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs2298181 9 130289951 [A/G] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs2247493 9 130296484 [T/G] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs2247374 9 130297246 [T/C] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs2243955 9 130303640 [A/G] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs7033360 9 130308439 [T/C] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs1891729 9 130309024 [T/C] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs2076904 9 130310173 [A/G] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs7854003 9 130310834 [A/G] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs2257055 9 130311404 [A/C] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs7035401 9 130313173 [A/G] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs4378065 9 130316561 [A/G] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs2253112 9 130320119 [T/C] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs2252968 9 130321117 [T/C] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs2252730 9 130323485 [T/G] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs10987687 9 130330131 [T/C] NM_022833,NM_001035534 FAM129B,FAM129B Silent,Silent rs4240418 9 130334178 [T/C] NM_001035534 FAM129B Silent rs10760490 9 130335418 [A/G] NM_001035534 FAM129B Silent rs4532699 9 130338333 [A/G] NM_001035534 FAM129B Silent rs1124602 9 130342992 [A/G] rs2417053 9 130349014 [A/G] rs12341585 9 130358236 [A/C] rs10987696 9 130363183 [A/G] rs10760492 9 130371985 [T/G] rs1573178 9 130372487 [T/C] rs7852204 9 130373596 [T/C] rs6478788 9 130376248 [A/G] NM_003165,NM_001032221 STXBP1,STXBP1 Silent,Silent rs10819302 9 130376287 [T/C] NM_003165,NM_001032221 STXBP1,STXBP1 Silent,Silent rs36081179 9 130402180 [T/C] NM_003165,NM_001032221 STXBP1,STXBP1 Silent,Silent rs17382675 9 130404935 [T/C] NM_003165,NM_001032221 STXBP1,STXBP1 Silent,Silent rs2287116 9 130420813 [T/G] NM_003165,NM_001032221 STXBP1,STXBP1 Silent,Silent rs2241167 9 130430116 [A/G] NM_003165,NM_001032221 STXBP1,STXBP1 Silent,Silent rs7862127 9 130430604 [T/C] NM_003165,NM_001032221 STXBP1,STXBP1 Silent,Silent rs7854204 9 130435904 [A/G] NM_003165,NM_001032221 STXBP1,STXBP1 Silent,Silent rs4837175 9 130439542 [A/C] NM_003165,NM_001032221 STXBP1,STXBP1 Silent,Silent rs3780660 9 130450803 [A/G] NM_003165,NM_001032221 STXBP1,STXBP1 Silent,Silent rs6478790 9 130450876 [A/G] NM_003165,NM_001032221 STXBP1,STXBP1 Silent,Silent rs7021991 9 130456157 [T/G] rs10123531 9 130460971 [T/G] rs522328 9 130475011 [T/C] NR_145961,NM_001012502 CFAP157,CFAP157 EXON Silent,Synonymous_S387S rs550045 9 130477160 [A/G] NM_001345980,NM_001002913,NM_001345978,NM_001345979,NM_001345977 PTRH1,PTRH1,PTRH1,PTRH1,PTRH1 Silent,Silent,Silent,Silent,Silent rs504434 9 130477768 [A/G] NM_001345980,NM_001002913,NM_001345978,NM_001345979,NM_001345977 PTRH1,PTRH1,PTRH1,PTRH1,PTRH1 Silent,Silent,Silent,Silent,Silent rs3802357 9 130478653 [A/G] NM_144965,NM_001317037 TTC16,TTC16 Silent,Silent rs7027128 9 130485363 [T/C] NM_144965,NM_001317037 TTC16,TTC16 Silent,Silent rs2256139 9 130486915 [T/C] NM_144965,NM_001317037 TTC16,TTC16 Silent,Silent rs472144 9 130489558 [A/G] NM_144965,NM_001317037 TTC16,TTC16 EXON Synonymous_K526K,Synonymous_K513K rs13298768 9 130489743 [A/G] NM_144965,NM_001317037 TTC16,TTC16 EXON Missense_E588G,Missense_E575G rs557749 9 130492039 [A/G] NM_144965,NM_001317037 TTC16,TTC16 Silent,Silent rs482095 9 130493513 [A/G] NM_144965,NM_001317037 TTC16,TTC16 EXON Synonymous_K817K,Synonymous_K804K rs534652 9 130494667 [A/G] NM_001252021,NM_001252018,NM_001252023,NM_001134431,NM_001134430,NM_001085347,NM_130459 TOR2A,TOR2A,TOR2A,TOR2A,TOR2A,TOR2A,TOR2A EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3739812 9 130495890 [A/C] NM_001252021,NM_001252018,NM_001252023,NM_001134431,NM_001134430,NM_001085347,NM_130459 TOR2A,TOR2A,TOR2A,TOR2A,TOR2A,TOR2A,TOR2A Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1999224 9 130498120 [T/G] rs34107454 9 130499749 [A/G] rs7852090 9 130502238 [T/C] NM_001142534,NM_005489,NM_001142532,NM_001142533,NM_001142531,NM_170600,NM_001252334 SH2D3C,SH2D3C,SH2D3C,SH2D3C,SH2D3C,SH2D3C,SH2D3C Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2233514 9 130502544 [T/C] NM_001142534,NM_005489,NM_001142532,NM_001142533,NM_001142531,NM_170600,NM_001252334 SH2D3C,SH2D3C,SH2D3C,SH2D3C,SH2D3C,SH2D3C,SH2D3C EXON Synonymous_E571E,Synonymous_E574E,Synonymous_E377E,Synonymous_E573E,Synonymous_E377E,Synonymous_E731E,Synonymous_E663E rs514024 9 130504070 [A/G] NM_001142534,NM_005489,NM_001142532,NM_001142533,NM_001142531,NM_170600,NM_001252334 SH2D3C,SH2D3C,SH2D3C,SH2D3C,SH2D3C,SH2D3C,SH2D3C EXON Synonymous_A535A,Synonymous_A538A,Synonymous_A341A,Synonymous_A537A,Synonymous_A341A,Synonymous_A695A,Synonymous_A627A rs10739696 9 130527786 [A/C] NM_005489,NM_170600,NM_001252334 SH2D3C,SH2D3C,SH2D3C Silent,Silent,Silent rs4836579 9 130528548 [T/C] NM_005489,NM_170600,NM_001252334 SH2D3C,SH2D3C,SH2D3C Silent,Silent,Silent rs10760500 9 130536717 [A/G] NM_170600 SH2D3C EXON Missense_L23F rs913990 9 130538720 [T/G] NM_170600 SH2D3C Silent rs1002095 9 130545950 [A/G] rs3217739 9 130549790 [T/C] NM_001261 CDK9 Silent rs3217748 9 130551449 [T/C] NM_001261 CDK9 Silent rs3217750 9 130551997 [A/G] NM_001261 CDK9 EXON Silent rs8083 9 130552179 [A/G] NM_001261 CDK9 EXON Silent rs12379987 9 130561688 [T/C] rs1544105 9 130562725 [T/C] rs7856096 9 130566539 [A/G] NM_004957,NM_001288803,NR_110170,NM_001018078 FPGS,FPGS,FPGS,FPGS Silent,Silent,Silent,Silent rs10106 9 130576075 [T/C] NM_004957,NM_001288803,NR_110170,NM_001018078 FPGS,FPGS,FPGS,FPGS EXON Silent,Silent,Silent,Silent rs4451422 9 130576597 [A/C] rs7018778 9 130577025 [T/C] rs10760503 9 130578404 [A/G] NM_001114753,NM_001278138,NM_000118,NR_136302 ENG,ENG,ENG,LOC102723566 EXON Silent,Silent,Silent,Silent rs5031024 9 130579904 [A/G] NM_001114753,NM_001278138,NM_000118,NR_136302 ENG,ENG,ENG,LOC102723566 Silent,Silent,Silent,Silent rs10987746 9 130580093 [T/C] NM_001114753,NM_001278138,NM_000118,NR_136302 ENG,ENG,ENG,LOC102723566 EXON Silent,Silent,Silent,Silent rs36092484 9 130586657 [A/G] NM_001114753,NM_001278138,NM_000118 ENG,ENG,ENG EXON Synonymous_L354L,Synonymous_L172L,Synonymous_L354L rs3739817 9 130586688 [A/G] NM_001114753,NM_001278138,NM_000118 ENG,ENG,ENG EXON Synonymous_T343T,Synonymous_T161T,Synonymous_T343T rs11792480 9 130598125 [A/G] NM_001114753,NM_001278138,NM_000118 ENG,ENG,ENG Silent,Silent,Silent rs41459245 9 130598300 [A/G] NM_001114753,NM_001278138,NM_000118 ENG,ENG,ENG Silent,Silent,Silent rs10819311 9 130602124 [T/C] NM_001114753,NM_001278138,NM_000118 ENG,ENG,ENG Silent,Silent,Silent rs10121110 9 130602408 [A/G] NM_001114753,NM_001278138,NM_000118 ENG,ENG,ENG Silent,Silent,Silent rs11789185 9 130607518 [T/G] NM_001114753,NM_001278138,NM_000118 ENG,ENG,ENG Silent,Silent,Silent rs10819312 9 130608296 [T/G] NM_001114753,NM_001278138,NM_000118 ENG,ENG,ENG Silent,Silent,Silent rs12379490 9 130612218 [A/C] NM_001114753,NM_000118 ENG,ENG Silent,Silent rs41421145 9 130612459 [A/G] NM_001114753,NM_000118 ENG,ENG Silent,Silent rs4837192 9 130614912 [A/G] NM_001114753,NM_000118 ENG,ENG Silent,Silent rs41527247 9 130615218 [A/G] NM_001114753,NM_000118 ENG,ENG Silent,Silent rs10115613 9 130615751 [A/G] NM_001114753,NM_000118 ENG,ENG Silent,Silent rs7033891 9 130616958 [T/C] NM_001114753,NM_000118 ENG,ENG EXON Silent,Silent rs7865146 9 130619637 [T/C] rs4837197 9 130622946 [T/C] rs1537034 9 130624723 [A/G] rs913987 9 130629139 [T/G] NM_001318121,NM_000476,NM_001318122 AK1,AK1,AK1 EXON Silent,Silent,Silent rs3780663 9 130631519 [T/C] NM_001318121,NM_000476,NM_001318122 AK1,AK1,AK1 Silent,Silent,Silent rs2094332 9 130633010 [A/G] NM_001318121,NM_000476,NM_001318122 AK1,AK1,AK1 Silent,Silent,Silent rs1556246 9 130633433 [T/C] NM_001318121,NM_000476,NM_001318122 AK1,AK1,AK1 Silent,Silent,Silent rs743539 9 130633904 [T/G] NM_001318121,NM_000476,NM_001318122 AK1,AK1,AK1 Silent,Silent,Silent rs743537 9 130634944 [T/C] NM_001318121,NM_000476,NM_001318122 AK1,AK1,AK1 Silent,Silent,Silent rs968463 9 130635937 [T/C] NM_001318121,NM_000476 AK1,AK1 Silent,Silent rs10819315 9 130645262 [T/C] rs2031696 9 130647583 [T/C] rs913983 9 130648680 [A/G] NR_104629,NM_001287001,NM_001287000,NM_001287003,NM_001287002,NM_001286999,NM_013443 ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3780670 9 130657833 [A/G] NR_104629,NM_001287001,NM_001287000,NM_001287003,NM_001287002,NM_001286999,NM_013443 ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7027357 9 130659406 [A/G] NR_104629,NM_001287001,NM_001287000,NM_001287003,NM_001287002,NM_001286999,NM_013443 ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3758330 9 130660232 [T/C] NR_104629,NM_001287000,NM_001287002,NM_001286999,NM_013443 ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6 Silent,Silent,Silent,Silent,Silent rs1571142 9 130660810 [A/G] NR_104629,NM_001287000,NM_001287002,NM_001286999,NM_013443 ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6,ST6GALNAC6 Silent,Silent,Silent,Silent,Silent rs12004868 9 130666337 [T/C] NR_104629,NM_001287002 ST6GALNAC6,ST6GALNAC6 Silent,Silent rs4837204 9 130668004 [T/C] rs16930158 9 130668090 [A/C] rs10819317 9 130668957 [A/G] rs10760510 9 130670095 [T/C] rs1127024 9 130670432 [A/G] NM_175040,NM_175039 ST6GALNAC4,ST6GALNAC4 EXON Silent,Silent rs3818509 9 130670532 [T/C] NM_175040,NM_175039 ST6GALNAC4,ST6GALNAC4 EXON Silent,Silent rs2274423 9 130670662 [T/C] NM_175040,NM_175039 ST6GALNAC4,ST6GALNAC4 EXON Silent,Silent rs3780668 9 130673419 [T/C] NM_175040,NM_175039 ST6GALNAC4,ST6GALNAC4 Silent,Silent rs10987776 9 130691933 [A/G] NM_001135219 PIP5KL1 Silent rs4836593 9 130696710 [A/G] rs10819321 9 130697328 [A/G] rs7997 9 130698029 [G/C] NM_003863 DPM2 EXON Missense_T76S rs3739821 9 130702477 [A/G] rs3824527 9 130702642 [T/C] rs7859 9 130703565 [A/G] NM_203305,NM_001035254 FAM102A,FAM102A EXON Silent,Silent rs1043060 9 130705120 [T/C] NM_203305,NM_001035254 FAM102A,FAM102A EXON Silent,Silent rs3802355 9 130713308 [A/C] NM_001035254 FAM102A Silent rs6415846 9 130716761 [A/G] NM_001035254 FAM102A Silent rs3780666 9 130727677 [T/C] NM_001035254 FAM102A Silent rs7865476 9 130735937 [T/G] NM_001035254 FAM102A Silent rs1078697 9 130737250 [T/C] NM_001035254 FAM102A Silent rs7032368 9 130755881 [A/G] rs7873657 9 130769800 [A/G] rs7874551 9 130770276 [T/G] rs947626 9 130774369 [A/C] rs4837223 9 130776407 [T/C] rs10760523 9 130776897 [T/C] rs7026544 9 130778514 [T/C] rs7852168 9 130782031 [A/G] rs10987837 9 130787509 [T/C] rs10987842 9 130793484 [T/C] rs7869490 9 130803687 [T/C] rs4837230 9 130806053 [T/G] rs10819341 9 130808444 [T/C] rs882895 9 130814366 [A/G] rs16930231 9 130814596 [T/G] rs10987850 9 130816609 [A/G] rs10987852 9 130819574 [A/G] rs1891409 9 130835598 [T/G] NM_001006641,NM_001330988 SLC25A25,SLC25A25 Silent,Silent rs4240425 9 130835780 [T/C] NM_001006641,NM_001330988 SLC25A25,SLC25A25 Silent,Silent rs10739708 9 130847209 [T/C] NM_001006641,NM_001330988 SLC25A25,SLC25A25 Silent,Silent rs6478815 9 130850879 [A/G] NM_001006641,NM_001330988 SLC25A25,SLC25A25 Silent,Silent rs10987871 9 130851573 [A/G] NM_001006641,NM_001330988 SLC25A25,SLC25A25 Silent,Silent rs10739712 9 130854127 [A/G] NM_001006641,NM_001330988,NM_001006642,NM_001265614 SLC25A25,SLC25A25,SLC25A25,SLC25A25 EXON Silent,Silent,Silent,Silent rs7042793 9 130854968 [T/C] NM_001006641,NM_001330988,NM_001006642,NM_001265614 SLC25A25,SLC25A25,SLC25A25,SLC25A25 Silent,Silent,Silent,Silent rs947623 9 130861039 [A/G] NM_001006641,NM_001330988,NM_001006642,NM_001265614,NM_052901,NR_049766 SLC25A25,SLC25A25,SLC25A25,SLC25A25,SLC25A25,SLC25A25 EXON Silent,Silent,Silent,Silent,Silent,Silent rs7872702 9 130870023 [T/C] NM_001006641,NM_001330988,NM_001006642,NM_001265614,NM_052901,NR_049766 SLC25A25,SLC25A25,SLC25A25,SLC25A25,SLC25A25,SLC25A25 EXON Silent,Silent,Silent,Silent,Silent,Silent rs4837240 9 130873428 [A/G] rs13283456 9 130884753 [T/C] NM_198938,NM_001256335,NM_025072 PTGES2,PTGES2,PTGES2 EXON Missense_R107H,Missense_R107H,Missense_R298H rs4837243 9 130889600 [T/C] NM_198938,NM_001256335,NM_025072 PTGES2,PTGES2,PTGES2 Silent,Silent,Silent rs12377832 9 130891060 [A/G] NR_024425 PTGES2-AS1 EXON Silent rs10987895 9 130909329 [T/C] rs3814526 9 130910687 [A/G] rs10987899 9 130918370 [T/C] rs11549260 9 130928633 [T/C] NM_012127,NM_001131018,NM_001131015,NM_001257975,NM_001257976,NM_001131016,NM_001131017 CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1 EXON Missense_R847Q,Missense_R767Q,Missense_R791Q,Missense_R903Q,Missense_R746Q,Missense_R847Q,Missense_R786Q rs10987905 9 130931586 [A/C] NM_012127,NM_001131018,NM_001131015,NM_001257975,NM_001257976,NM_001131016,NM_001131017 CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7847286 9 130935956 [A/G] NM_012127,NM_001131018,NM_001131015,NM_001257975,NM_001257976,NM_001131016,NM_001131017 CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7847709 9 130936003 [A/G] NM_012127,NM_001131018,NM_001131015,NM_001257975,NM_001257976,NM_001131016,NM_001131017 CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10987908 9 130936530 [T/C] NM_012127,NM_001131018,NM_001131015,NM_001257975,NM_001257976,NM_001131016,NM_001131017 CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs870451 9 130937738 [A/C] NM_012127,NM_001131018,NM_001131015,NM_001257975,NM_001257976,NM_001131016,NM_001131017 CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3892074 9 130940822 [T/C] NM_012127,NM_001131018,NM_001131015,NM_001257975,NM_001257976,NM_001131016,NM_001131017 CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10987911 9 130945298 [A/G] NM_012127,NM_001131018,NM_001131015,NM_001257975,NM_001257976,NM_001131016,NM_001131017 CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1,CIZ1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10760548 9 130965235 [A/G] NM_012127,NM_001131015 CIZ1,CIZ1 Silent,Silent rs3003569 9 130967288 [A/G] NM_001005336,NM_001288737,NM_001288738,NM_004408,NM_001288739 DNM1,DNM1,DNM1,DNM1,DNM1 Silent,Silent,Silent,Silent,Silent rs2502817 9 130971586 [T/C] NM_001005336,NM_001288737,NM_001288738,NM_004408,NM_001288739 DNM1,DNM1,DNM1,DNM1,DNM1 Silent,Silent,Silent,Silent,Silent rs3003599 9 130979181 [A/G] NM_001005336,NM_001288737,NM_001288738,NM_004408,NM_001288739 DNM1,DNM1,DNM1,DNM1,DNM1 Silent,Silent,Silent,Silent,Silent rs3003609 9 130984755 [T/C] NM_001005336,NM_001288737,NM_001288738,NM_004408,NM_001288739 DNM1,DNM1,DNM1,DNM1,DNM1 EXON Synonymous_F336F,Synonymous_F336F,Synonymous_F336F,Synonymous_F336F,Synonymous_F336F rs3003578 9 130994179 [T/C] NM_001005336,NM_001288737,NM_001288738,NM_004408,NM_001288739 DNM1,DNM1,DNM1,DNM1,DNM1 Silent,Silent,Silent,Silent,Silent rs13285411 9 130997868 [A/C] NM_001005336,NM_001288737,NM_001288738,NM_004408,NM_001288739 DNM1,DNM1,DNM1,DNM1,DNM1 Silent,Silent,Silent,Silent,Silent rs9644916 9 130998850 [T/C] NM_001005336,NM_001288737,NM_001288738,NM_004408,NM_001288739 DNM1,DNM1,DNM1,DNM1,DNM1 Silent,Silent,Silent,Silent,Silent rs1004464 9 131003677 [A/G] NM_001005336,NM_001288737,NM_001288738,NM_004408,NM_001288739 DNM1,DNM1,DNM1,DNM1,DNM1 Silent,Silent,Silent,Silent,Silent rs2302425 9 131010726 [A/G] NM_001005336,NM_001288737,NM_001288738,NM_004408,NM_001288739 DNM1,DNM1,DNM1,DNM1,DNM1 Silent,Silent,Silent,Silent,Silent rs7019135 9 131014606 [T/G] NM_001005336,NM_001288737,NM_001288738,NM_004408,NM_001288739 DNM1,DNM1,DNM1,DNM1,DNM1 Silent,Silent,Silent,Silent,Silent rs2005733 9 131017701 [A/G] rs7023913 9 131017962 [A/G] rs4734 9 131018639 [T/G] NM_004486 GOLGA2 EXON Silent rs10119788 9 131022175 [A/G] NM_004486 GOLGA2 Silent rs12347709 9 131023105 [A/G] NM_004486 GOLGA2 Silent rs12338625 9 131023141 [T/C] NM_004486 GOLGA2 Silent rs4271068 9 131032358 [A/G] NM_004486 GOLGA2 Silent rs2240960 9 131039250 [A/C] NM_001318092,NM_001318089,NM_001040011 SWI5,SWI5,SWI5 Silent,Silent,Silent rs2270204 9 131042734 [T/G] NM_001318092,NM_001318089,NM_001040011 SWI5,SWI5,SWI5 Silent,Silent,Silent rs2286816 9 131051254 [A/G] NM_001318092,NM_001318089,NM_001040011 SWI5,SWI5,SWI5 EXON Silent,Silent,Silent rs10114273 9 131055525 [A/G] rs7032645 9 131070859 [T/C] rs2231638 9 131073176 [T/C] NM_001329863,NM_001329861,NM_001329862,NM_015679 TRUB2,TRUB2,TRUB2,TRUB2 EXON Synonymous_E116E,Synonymous_E176E,Synonymous_E164E,Synonymous_E220E rs2231632 9 131079424 [T/C] NM_001329863,NM_001329861,NM_001329862,NM_015679 TRUB2,TRUB2,TRUB2,TRUB2 Silent,Silent,Silent,Silent rs6478825 9 131083692 [T/C] NM_001329863,NM_001329861,NM_001329862,NM_015679 TRUB2,TRUB2,TRUB2,TRUB2 Silent,Silent,Silent,Silent rs16930351 9 131087837 [A/G] NM_016035,NM_001305942 COQ4,COQ4 Silent,Silent rs2270203 9 131088076 [A/G] NM_016035,NM_001305942 COQ4,COQ4 EXON Synonymous_S106S,Missense_R74Q rs3003600 9 131088464 [T/C] NM_016035,NM_001305942 COQ4,COQ4 Silent,Silent rs11790049 9 131090173 [T/C] NM_016035,NM_001305942 COQ4,COQ4 Silent,Silent rs7850697 9 131095112 [A/C] NM_016035,NM_001305942 COQ4,COQ4 Silent,Silent rs2240954 9 131095332 [T/C] NM_016035,NM_001305942 COQ4,COQ4 Silent,Silent rs7030121 9 131101919 [A/G] rs10987965 9 131110443 [A/G] NM_005094 SLC27A4 Silent rs2240953 9 131110892 [A/G] NM_005094 SLC27A4 EXON Missense_G209S rs16930354 9 131115923 [T/C] NM_005094,NR_031672 SLC27A4,MIR1268A Silent,Silent rs2003560 9 131118222 [A/G] NM_005094,NR_031672 SLC27A4,MIR1268A Silent,Silent rs6478827 9 131120452 [T/C] NM_005094,NR_031672 SLC27A4,MIR1268A Silent,Silent rs7048106 9 131123542 [A/G] NM_005094,NR_031672 SLC27A4,MIR1268A EXON Silent,Silent rs3003620 9 131123875 [T/C] NR_031672 MIR1268A Silent rs10124204 9 131129207 [T/C] NR_031672 MIR1268A Silent rs7019382 9 131132758 [T/C] NR_031672 MIR1268A Silent rs2286814 9 131133983 [A/C] NR_031672,NR_049743,NM_001265582,NM_001135947,NM_030914 MIR1268A,URM1,URM1,URM1,URM1 Silent,Silent,Silent,Silent,Silent rs2240949 9 131144904 [A/G] NR_031672,NR_049743,NM_001265582,NM_001135947,NM_030914 MIR1268A,URM1,URM1,URM1,URM1 Silent,Silent,Silent,Silent,Silent rs2240946 9 131150601 [A/G] NR_031672,NR_049743,NM_001265582,NM_001135947,NM_030914 MIR1268A,URM1,URM1,URM1,URM1 EXON Silent,Silent,Silent,Silent,Silent rs10987973 9 131150736 [A/C] NR_031672,NR_049743,NM_001265582,NM_001135947,NM_030914 MIR1268A,URM1,URM1,URM1,URM1 EXON Silent,Silent,Silent,Silent,Silent rs12351561 9 131169528 [T/C] NR_031672 MIR1268A Silent rs7861180 9 131181991 [T/C] NR_031672,NM_001286760 MIR1268A,CERCAM Silent,Silent rs2072400 9 131185961 [A/G] NR_031672,NM_001286760,NM_016174 MIR1268A,CERCAM,CERCAM Silent,Silent,Silent rs16936865 9 131189316 [A/C] NR_031672,NM_001286760,NM_016174 MIR1268A,CERCAM,CERCAM Silent,Silent,Silent rs2270202 9 131191403 [A/G] NR_031672,NM_001286760,NM_016174 MIR1268A,CERCAM,CERCAM Silent,Silent,Silent rs7258 9 131196695 [T/C] NR_031672,NM_001286760,NM_016174 MIR1268A,CERCAM,CERCAM EXON Silent,Synonymous_L368L,Synonymous_L446L rs6918 9 131199576 [A/C] NR_031672,NM_001286760,NM_016174 MIR1268A,CERCAM,CERCAM EXON Silent,Silent,Silent rs4837264 9 131201895 [A/G] NR_031672 MIR1268A Silent rs7870167 9 131210643 [T/C] NR_031672 MIR1268A Silent rs7849186 9 131212372 [A/G] NR_031672 MIR1268A Silent rs7032246 9 131224189 [T/C] NR_031672,NM_001351584,NM_153436,NM_001351580,NM_001351578,NM_001351579,NM_001351585,NM_001242352,NM_001351583,NM_001242354,NM_001351581,NM_001242353,NM_001351587,NM_153439,NM_001351588,NM_002540,NM_001351586,NM_153432,NM_001351577,NM_001351582,NM_153435,NM_153440,NM_153433,NM_153437 MIR1268A,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4512487 9 131235321 [A/G] NR_031672,NM_001351584,NM_153436,NM_001351580,NM_001351578,NM_001351579,NM_001351585,NM_001242352,NM_001351583,NM_001242354,NM_001351581,NM_001242353,NM_001351587,NM_153439,NM_001351588,NM_002540,NM_001351586,NM_153432,NM_001351577,NM_001351582,NM_153435,NM_153440,NM_153433,NM_153437 MIR1268A,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12347774 9 131236201 [T/C] NR_031672,NM_001351584,NM_153436,NM_001351580,NM_001351578,NM_001351579,NM_001351585,NM_001242352,NM_001351583,NM_001242354,NM_001351581,NM_001242353,NM_001351587,NM_153439,NM_001351588,NM_002540,NM_001351586,NM_153432,NM_001351577,NM_001351582,NM_153435,NM_153440,NM_153433,NM_153437 MIR1268A,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1133750 9 131262957 [A/G] NR_031672,NM_001351584,NM_001351580,NM_001351578,NM_001351579,NM_001351585,NM_001242352,NM_001351583,NM_001351581,NM_001242353,NM_001351587,NM_001351588,NM_002540,NM_001351586,NM_001351577,NM_001351582,NM_153435,NM_153433 MIR1268A,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2,ODF2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10988011 9 131266818 [A/C] NR_031672 MIR1268A Silent rs2275260 9 131285955 [A/G] NR_031672,NM_001499,NM_001003722 MIR1268A,GLE1,GLE1 EXON Silent,Missense_I243V,Missense_I243V rs10988014 9 131287352 [T/C] NR_031672,NM_001499,NM_001003722 MIR1268A,GLE1,GLE1 Silent,Silent,Silent rs10115092 9 131292514 [A/C] NR_031672,NM_001499,NM_001003722 MIR1268A,GLE1,GLE1 Silent,Silent,Silent rs7871140 9 131299228 [T/C] NR_031672,NM_001499,NM_001003722 MIR1268A,GLE1,GLE1 Silent,Silent,Silent rs16930441 9 131300442 [A/G] NR_031672,NM_001499,NM_001003722 MIR1268A,GLE1,GLE1 Silent,Silent,Silent rs10760563 9 131303522 [A/G] NR_031672,NM_001003722 MIR1268A,GLE1 EXON Silent,Silent rs10513496 9 131303630 [A/C] NR_031672,NM_001003722 MIR1268A,GLE1 EXON Silent,Silent rs10513497 9 131311128 [T/C] NR_031672 MIR1268A Silent rs11999274 9 131311333 [A/G] NR_031672 MIR1268A Silent rs945832 9 131321301 [A/G] NR_031672,NM_001195532,NM_003127,NM_001130438,NM_001363765,NM_001363759 MIR1268A,SPTAN1,SPTAN1,SPTAN1,SPTAN1,SPTAN1 Silent,Silent,Silent,Silent,Silent,Silent rs10819410 9 131327982 [A/C] NR_031672,NM_001195532,NM_003127,NM_001130438,NM_001363765,NM_001363759 MIR1268A,SPTAN1,SPTAN1,SPTAN1,SPTAN1,SPTAN1 Silent,Silent,Silent,Silent,Silent,Silent rs2152833 9 131331320 [T/C] NR_031672,NM_001195532,NM_003127,NM_001130438,NM_001363765,NM_001363759 MIR1268A,SPTAN1,SPTAN1,SPTAN1,SPTAN1,SPTAN1 Silent,Silent,Silent,Silent,Silent,Silent rs10819411 9 131334744 [T/C] NR_031672,NM_001195532,NM_003127,NM_001130438,NM_001363765,NM_001363759 MIR1268A,SPTAN1,SPTAN1,SPTAN1,SPTAN1,SPTAN1 Silent,Silent,Silent,Silent,Silent,Silent rs2297771 9 131337843 [A/G] NR_031672,NM_001195532,NM_003127,NM_001130438,NM_001363765,NM_001363759 MIR1268A,SPTAN1,SPTAN1,SPTAN1,SPTAN1,SPTAN1 Silent,Silent,Silent,Silent,Silent,Silent rs10760566 9 131346218 [A/C] NR_031672,NM_001195532,NM_003127,NM_001130438,NM_001363765,NM_001363759 MIR1268A,SPTAN1,SPTAN1,SPTAN1,SPTAN1,SPTAN1 EXON Silent,Synonymous_A721A,Synonymous_A721A,Synonymous_A721A,Synonymous_A721A,Synonymous_A721A rs4307429 9 131351046 [A/G] NR_031672,NM_001195532,NM_003127,NM_001130438,NM_001363765,NM_001363759 MIR1268A,SPTAN1,SPTAN1,SPTAN1,SPTAN1,SPTAN1 Silent,Silent,Silent,Silent,Silent,Silent rs945831 9 131362361 [T/C] NR_031672,NM_001195532,NM_003127,NM_001130438,NM_001363765,NM_001363759 MIR1268A,SPTAN1,SPTAN1,SPTAN1,SPTAN1,SPTAN1 EXON Silent,Synonymous_D1162D,Synonymous_D1182D,Synonymous_D1182D,Synonymous_D1162D,Synonymous_D1182D rs7357662 9 131370756 [T/C] NR_031672,NM_001195532,NM_003127,NM_001130438,NM_001363765,NM_001363759 MIR1268A,SPTAN1,SPTAN1,SPTAN1,SPTAN1,SPTAN1 Silent,Silent,Silent,Silent,Silent,Silent rs3750334 9 131379967 [T/C] NR_031672,NM_001195532,NM_003127,NM_001130438,NM_001363765,NM_001363759 MIR1268A,SPTAN1,SPTAN1,SPTAN1,SPTAN1,SPTAN1 EXON Silent,Synonymous_T1777T,Synonymous_T1797T,Synonymous_T1802T,Synonymous_T1782T,Synonymous_T1802T rs3750333 9 131379998 [A/C] NR_031672,NM_001195532,NM_003127,NM_001130438,NM_001363765,NM_001363759 MIR1268A,SPTAN1,SPTAN1,SPTAN1,SPTAN1,SPTAN1 EXON Silent,Synonymous_R1788R,Synonymous_R1808R,Synonymous_R1813R,Synonymous_R1793R,Synonymous_R1813R rs7864187 9 131380225 [A/C] NR_031672,NM_001195532,NM_003127,NM_001130438,NM_001363765,NM_001363759 MIR1268A,SPTAN1,SPTAN1,SPTAN1,SPTAN1,SPTAN1 Silent,Silent,Silent,Silent,Silent,Silent rs16930539 9 131392593 [T/C] NR_031672,NM_001195532,NM_003127,NM_001130438,NM_001363765,NM_001363759 MIR1268A,SPTAN1,SPTAN1,SPTAN1,SPTAN1,SPTAN1 Silent,Silent,Silent,Silent,Silent,Silent rs10760569 9 131394297 [A/G] NR_031672,NM_001195532,NM_003127,NM_001130438,NM_001363765,NM_001363759 MIR1268A,SPTAN1,SPTAN1,SPTAN1,SPTAN1,SPTAN1 Silent,Silent,Silent,Silent,Silent,Silent rs4837291 9 131397479 [A/G] NR_031672,NM_052844 MIR1268A,WDR34 EXON Silent,Synonymous_T291T rs10760570 9 131398636 [T/C] NR_031672,NM_052844 MIR1268A,WDR34 EXON Silent,Synonymous_Q209Q rs2298045 9 131403096 [A/G] NR_031672,NM_052844 MIR1268A,WDR34 EXON Silent,Synonymous_Y103Y rs4397511 9 131406739 [A/G] NR_031672,NM_052844 MIR1268A,WDR34 Silent,Silent rs16936868 9 131406896 [T/C] NR_031672,NM_052844 MIR1268A,WDR34 Silent,Silent rs10988067 9 131410039 [A/G] NR_031672,NM_052844 MIR1268A,WDR34 Silent,Silent rs2298038 9 131419422 [T/C] NR_031672 MIR1268A Silent rs4836617 9 131437159 [T/C] rs10988087 9 131443671 [A/G] rs10988093 9 131457125 [A/G] NM_001122821,NM_001248000,NM_003011,NM_001248001 SET,SET,SET,SET EXON Silent,Silent,Silent,Silent rs12554024 9 131464046 [T/C] rs9697210 9 131468740 [A/G] NM_013355,NM_001317926 PKN3,PKN3 Silent,Silent rs10739729 9 131479023 [T/C] NM_013355,NM_001317926 PKN3,PKN3 Silent,Silent rs3750325 9 131482467 [T/C] NM_013355,NM_001317926 PKN3,PKN3 Silent,Silent rs7874430 9 131482517 [A/G] NM_013355,NM_001317926 PKN3,PKN3 EXON Synonymous_A804A,Synonymous_A804A rs3750326 9 131483235 [A/G] NM_032799,NM_001318020,NM_001318023,NM_001318015,NM_001318016 ZDHHC12,ZDHHC12,ZDHHC12,ZDHHC12,ZDHHC12 EXON Silent,Silent,Silent,Silent,Silent rs10988105 9 131484526 [T/C] NM_032799,NM_001318020,NM_001318023,NM_001318015,NM_001318016 ZDHHC12,ZDHHC12,ZDHHC12,ZDHHC12,ZDHHC12 Silent,Silent,Silent,Silent,Silent rs2298039 9 131484749 [A/G] NM_032799,NM_001318020,NM_001318023,NM_001318015,NM_001318016 ZDHHC12,ZDHHC12,ZDHHC12,ZDHHC12,ZDHHC12 EXON Missense_P69S,Missense_P69S,Missense_P69S,Missense_P124S,Missense_P69S rs10760575 9 131489451 [A/C] NR_046240 LOC100506100 Silent rs7857011 9 131490808 [A/G] NR_046240 LOC100506100 Silent rs4837299 9 131491551 [A/G] NR_046240 LOC100506100 Silent rs1129169 9 131493140 [A/G] NR_046240,NM_006336 LOC100506100,ZER1 EXON Silent,Silent rs13299702 9 131504080 [A/G] NM_006336 ZER1 EXON Missense_T539I rs8507 9 131515547 [T/G] NM_006336 ZER1 EXON Synonymous_A214A rs4836625 9 131516838 [T/C] NM_006336 ZER1 Silent rs10739734 9 131527676 [T/G] NM_006336 ZER1 Silent rs4836628 9 131555306 [A/G] NM_001286772,NM_018201 TBC1D13,TBC1D13 Silent,Silent rs2417126 9 131562457 [T/C] NM_001286772,NM_018201 TBC1D13,TBC1D13 Silent,Silent rs1572912 9 131565554 [T/C] NM_001286772,NM_018201 TBC1D13,TBC1D13 EXON Silent,Missense_V190A rs12235388 9 131570593 [T/C] NM_001286772,NM_018201 TBC1D13,TBC1D13 EXON Silent,Silent rs16930661 9 131571236 [T/C] NM_001286772,NM_018201 TBC1D13,TBC1D13 EXON Silent,Silent rs11999937 9 131571568 [T/C] NM_001286772,NM_018201 TBC1D13,TBC1D13 EXON Silent,Silent rs15676 9 131572027 [A/G] NM_001286772,NM_018201 TBC1D13,TBC1D13 EXON Silent,Silent rs3829901 9 131572215 [T/C] NM_001286772,NM_018201 TBC1D13,TBC1D13 EXON Silent,Silent rs2997922 9 131580744 [T/C] rs10819449 9 131582104 [A/G] NM_004435,NM_016390 ENDOG,SPOUT1 EXON Silent,Silent rs2977996 9 131582625 [A/G] NM_004435,NM_016390 ENDOG,SPOUT1 EXON Silent,Silent rs2280845 9 131583170 [T/C] NM_004435,NM_016390 ENDOG,SPOUT1 EXON Silent,Silent rs2280844 9 131584631 [T/C] NM_004435,NM_016390 ENDOG,SPOUT1 EXON Synonymous_Y212Y,Silent rs2280843 9 131585069 [A/G] NM_016390 SPOUT1 EXON Missense_I369T rs7029309 9 131585873 [A/G] NM_016390 SPOUT1 Silent rs7033070 9 131586374 [A/G] NM_016390 SPOUT1 EXON Synonymous_A297A rs3817684 9 131589409 [T/C] NM_016390 SPOUT1 EXON Synonymous_P90P rs12335581 9 131590390 [T/G] NM_016390 SPOUT1 Silent rs2293964 9 131592150 [A/G] rs35610387 9 131594325 [T/C] rs10988134 9 131595407 [T/C] NM_001352993,NM_001122672,NM_001352992,NM_001122671,NM_001352990,NR_109829,NR_148224,NR_148225,NM_001287390,NM_001352996,NM_001352995,NM_001352999,NM_004059,NM_001352998,NM_001352988,NM_001352989,NM_001352997,NM_001352994,NM_001352991 KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12336854 9 131600694 [T/C] NM_001352993,NM_001122672,NM_001352992,NM_001122671,NM_001352990,NR_109829,NR_148224,NR_148225,NM_001287390,NM_001352996,NM_001352995,NM_001352999,NM_004059,NM_001352998,NM_001352988,NM_001352989,NM_001352997,NM_001352994,NM_001352991 KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3763597 9 131609974 [T/C] NM_001122672,NM_001352992,NM_001122671,NM_001352990,NR_109829,NR_148224,NR_148225,NM_001287390,NM_001352996,NM_001352995,NM_001352999,NM_004059,NM_001352998,NM_001352988,NM_001352989,NM_001352997,NM_001352994,NM_001352991 KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12551773 9 131620132 [A/G] NM_001122672,NM_001352992,NM_001122671,NM_001352990,NR_109829,NR_148224,NR_148225,NM_001287390,NM_001352996,NM_001352995,NM_001352999,NM_004059,NM_001352998,NM_001352988,NM_001352989,NM_001352997,NM_001352994,NM_001352991 KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12005428 9 131640165 [A/G] NM_001122672,NM_001352992,NM_001122671,NM_001352990,NR_109829,NR_148224,NM_001287390,NM_001352996,NM_001352995,NM_001352999,NM_004059,NM_001352998,NM_001352988,NM_001352989,NM_001352997,NM_001352994,NM_001352991 KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1923619 9 131644307 [T/G] NM_001122672,NM_001352992,NM_001122671,NM_001352990,NR_109829,NR_148224,NM_001287390,NM_001352996,NM_001352995,NM_001352999,NM_004059,NM_001352998,NM_001352988,NM_001352989,NM_001352997,NM_001352994,NM_001352991 KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1,KYAT1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10988141 9 131646429 [T/G] NM_019594,NM_001127245,NM_001127244 LRRC8A,LRRC8A,LRRC8A Silent,Silent,Silent rs7860319 9 131669425 [T/C] NM_019594,NM_001127245,NM_001127244 LRRC8A,LRRC8A,LRRC8A Silent,Silent,Silent rs16930747 9 131669776 [T/C] NM_019594,NM_001127245,NM_001127244 LRRC8A,LRRC8A,LRRC8A EXON Synonymous_A111A,Synonymous_A111A,Synonymous_A111A rs3750320 9 131670457 [T/C] NM_019594,NM_001127245,NM_001127244 LRRC8A,LRRC8A,LRRC8A EXON Synonymous_Y338Y,Synonymous_Y338Y,Synonymous_Y338Y rs3750319 9 131670919 [T/C] NM_019594,NM_001127245,NM_001127244 LRRC8A,LRRC8A,LRRC8A EXON Synonymous_R492R,Synonymous_R492R,Synonymous_R492R rs3750318 9 131670952 [T/C] NM_019594,NM_001127245,NM_001127244 LRRC8A,LRRC8A,LRRC8A EXON Synonymous_T503T,Synonymous_T503T,Synonymous_T503T rs6478856 9 131672153 [A/G] NM_019594,NM_001127245,NM_001127244 LRRC8A,LRRC8A,LRRC8A Silent,Silent,Silent rs10988151 9 131672558 [A/G] NM_019594,NM_001127245,NM_001127244 LRRC8A,LRRC8A,LRRC8A Silent,Silent,Silent rs11789878 9 131675360 [T/G] NM_019594,NM_001127245,NM_001127244 LRRC8A,LRRC8A,LRRC8A Silent,Silent,Silent rs16930764 9 131676550 [A/G] NM_019594,NM_001127245,NM_001127244 LRRC8A,LRRC8A,LRRC8A Silent,Silent,Silent rs9031 9 131679892 [T/C] NM_019594,NM_001127245,NM_001127244 LRRC8A,LRRC8A,LRRC8A EXON Silent,Silent,Silent rs11542344 9 131680177 [T/G] NM_019594,NM_001127245,NM_001127244 LRRC8A,LRRC8A,LRRC8A EXON Silent,Silent,Silent rs12002353 9 131681361 [A/G] rs7048932 9 131687338 [T/C] NM_001100876,NM_174933,NM_001100877 PHYHD1,PHYHD1,PHYHD1 Silent,Silent,Silent rs28365521 9 131699571 [A/G] NM_001100876,NM_174933,NM_001100877 PHYHD1,PHYHD1,PHYHD1 Silent,Silent,Silent rs2273866 9 131702891 [A/G] NM_001100876,NM_174933,NM_001100877 PHYHD1,PHYHD1,PHYHD1 EXON Synonymous_R200R,Missense_E193G,Synonymous_R179R rs10988159 9 131702955 [T/C] NM_001100876,NM_174933,NM_001100877 PHYHD1,PHYHD1,PHYHD1 EXON Missense_R222W,Synonymous_P214P,Missense_R201W rs10115980 9 131704122 [T/C] NM_001100876,NM_174933,NM_001100877 PHYHD1,PHYHD1,PHYHD1 EXON Silent,Silent,Silent rs17432839 9 131705763 [A/G] rs10988163 9 131707333 [T/G] rs17485436 9 131708912 [A/T] NM_014908 DOLK EXON Missense_D224V rs28365523 9 131709221 [A/C] NM_014908 DOLK EXON Missense_V121G rs17507964 9 131730791 [A/C] NM_015354 NUP188 EXON Missense_R198S rs12337718 9 131731480 [A/G] NM_015354 NUP188 Silent rs10760583 9 131737339 [T/C] NM_015354 NUP188 Silent rs11564103 9 131741633 [A/G] NM_015354 NUP188 Silent rs719703 9 131745548 [T/C] NM_015354 NUP188 Silent rs17481317 9 131757125 [A/G] NM_015354 NUP188 Silent rs2302811 9 131761899 [A/G] NM_015354 NUP188 Silent rs17485646 9 131764115 [A/G] NM_015354 NUP188 Silent rs17433024 9 131765214 [T/C] NM_015354 NUP188 EXON Missense_A1419V rs2287363 9 131767668 [A/C] NM_015354 NUP188 EXON Synonymous_S1532S rs17485667 9 131768191 [A/G] NM_015354 NUP188 Silent rs35561135 9 131768372 [T/G] NM_015354 NUP188 EXON Missense_S1638I rs8206 9 131769243 [A/G] NM_015354 NUP188 EXON Silent rs11537524 9 131770786 [A/G] NM_001287045,NM_020145,NM_001287046 SH3GLB2,SH3GLB2,SH3GLB2 EXON Silent,Silent,Silent rs3750340 9 131772389 [T/G] NM_001287045,NM_020145,NM_001287046 SH3GLB2,SH3GLB2,SH3GLB2 Silent,Silent,Silent rs12554941 9 131772470 [T/C] NM_001287045,NM_020145,NM_001287046 SH3GLB2,SH3GLB2,SH3GLB2 EXON Missense_V227M,Missense_V223M,Missense_V223M rs10819457 9 131776041 [T/C] NM_001287045,NM_020145,NM_001287046 SH3GLB2,SH3GLB2,SH3GLB2 Silent,Silent,Silent rs7042889 9 131795361 [A/C] rs10760585 9 131796961 [T/C] rs11564101 9 131799261 [T/C] NR_138424,NR_138422,NR_138423,NR_138421,NM_001329990,NR_138425,NM_032809 MIGA2,MIGA2,MIGA2,MIGA2,MIGA2,MIGA2,MIGA2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Synonymous_G5G rs16930845 9 131804785 [T/C] NR_138424,NR_138422,NR_138423,NR_138421,NM_001329990,NR_138425,NM_032809 MIGA2,MIGA2,MIGA2,MIGA2,MIGA2,MIGA2,MIGA2 EXON Silent,Silent,Silent,Silent,Missense_V100A,Silent,Missense_V164A rs12001773 9 131828285 [A/G] NR_138424,NR_138422,NR_138423,NR_138421,NM_001329990,NR_138425,NM_032809 MIGA2,MIGA2,MIGA2,MIGA2,MIGA2,MIGA2,MIGA2 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10988190 9 131833100 [A/G] NR_138424,NR_138422,NR_138423,NR_138421,NM_001329990,NR_138425,NM_032809 MIGA2,MIGA2,MIGA2,MIGA2,MIGA2,MIGA2,MIGA2 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11564100 9 131834811 [A/G] rs4295766 9 131838821 [T/C] rs11789383 9 131839031 [A/C] rs10819461 9 131841887 [T/C] rs28365568 9 131843283 [A/G] rs11564097 9 131845354 [T/C] NR_072983,NM_001135917,NM_020438 DOLPP1,DOLPP1,DOLPP1 Silent,Silent,Silent rs10988198 9 131846125 [T/C] NR_072983,NM_001135917,NM_020438 DOLPP1,DOLPP1,DOLPP1 Silent,Silent,Silent rs11564096 9 131846957 [T/C] NR_072983,NM_001135917,NM_020438 DOLPP1,DOLPP1,DOLPP1 EXON Silent,Synonymous_S29S,Synonymous_S29S rs3750335 9 131847462 [A/G] NR_072983,NM_001135917,NM_020438 DOLPP1,DOLPP1,DOLPP1 Silent,Silent,Silent rs7046961 9 131849036 [T/C] NR_072983,NM_001135917,NM_020438 DOLPP1,DOLPP1,DOLPP1 EXON Silent,Synonymous_N170N,Synonymous_N213N rs12342339 9 131852500 [T/G] NR_072983,NM_001135917,NM_020438 DOLPP1,DOLPP1,DOLPP1 EXON Silent,Silent,Silent rs13289043 9 131855418 [A/G] rs11559172 9 131857520 [A/C] NM_000755,NM_001257363,NM_001346548,NM_001346546,NM_001346547,NM_001346549,NM_004003 CRAT,CRAT,CRAT,CRAT,CRAT,CRAT,CRAT EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16930895 9 131860421 [A/G] NM_000755,NM_001257363,NM_001346548,NM_001346546,NM_001346547,NM_001346549,NM_004003 CRAT,CRAT,CRAT,CRAT,CRAT,CRAT,CRAT EXON Synonymous_Y445Y,Synonymous_Y424Y,Synonymous_Y424Y,Synonymous_Y446Y,Synonymous_Y445Y,Synonymous_Y405Y,Synonymous_Y424Y rs3118635 9 131860901 [T/G] NM_000755,NM_001257363,NM_001346548,NM_001346546,NM_001346547,NM_001346549,NM_004003 CRAT,CRAT,CRAT,CRAT,CRAT,CRAT,CRAT EXON Missense_L372M,Missense_L351M,Missense_L351M,Missense_L373M,Missense_L372M,Missense_L332M,Missense_L351M rs1359845 9 131865100 [A/G] NM_000755,NM_001257363,NM_001346548,NM_001346546,NM_001346547,NM_001346549,NM_004003 CRAT,CRAT,CRAT,CRAT,CRAT,CRAT,CRAT Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10988209 9 131871927 [A/G] NM_000755,NM_001257363,NM_001346548,NM_001346546,NM_001346547,NM_001346549,NM_004003 CRAT,CRAT,CRAT,CRAT,CRAT,CRAT,CRAT Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3814492 9 131873222 [A/G] rs3118625 9 131873256 [A/C] NM_021131 PTPA EXON Silent rs2541161 9 131884802 [T/C] NM_021131,NM_178001,NM_178000,NM_178003,NM_001271832,NM_001193397 PTPA,PTPA,PTPA,PTPA,PTPA,PTPA Silent,Silent,Silent,Silent,Silent,Silent rs17455845 9 131899587 [T/C] NM_021131,NM_178001,NM_178000,NM_178003,NM_001271832,NM_001193397 PTPA,PTPA,PTPA,PTPA,PTPA,PTPA Silent,Silent,Silent,Silent,Silent,Silent rs3118634 9 131905854 [A/G] NM_021131,NM_178001,NM_178000,NM_178003,NM_001271832,NM_001193397 PTPA,PTPA,PTPA,PTPA,PTPA,PTPA Silent,Silent,Silent,Silent,Silent,Silent rs2480452 9 131909736 [T/C] NM_021131,NM_178001,NM_178000,NM_178003,NM_001271832,NM_001193397 PTPA,PTPA,PTPA,PTPA,PTPA,PTPA EXON Missense_S322L,Missense_S357L,Missense_S322L,Missense_S280L,Missense_S293L,Missense_S287L rs4837345 9 131923949 [T/C] rs7036689 9 131924038 [A/G] rs10739743 9 131932940 [A/C] rs2148851 9 131934238 [A/G] rs1075650 9 131938913 [T/C] NM_203434 IER5L EXON Silent rs7034195 9 131941309 [A/C] rs10988239 9 131943440 [T/C] rs913264 9 131944138 [T/C] rs7871824 9 131948373 [A/C] rs10760593 9 131953598 [T/C] rs6478869 9 131956834 [T/C] rs422134 9 131960107 [T/G] rs4836643 9 131960131 [A/G] rs2417135 9 131960870 [T/C] rs10988248 9 131963745 [A/G] rs10760594 9 131964881 [T/C] rs6478871 9 131968926 [T/C] rs7856501 9 131969556 [T/C] rs17482156 9 131971951 [A/C] rs10988252 9 131980567 [T/C] rs9409313 9 131982097 [T/C] rs2479030 9 131982125 [T/C] rs7873242 9 131984217 [A/G] rs4836644 9 131984706 [T/G] rs2479028 9 131986809 [T/C] rs2480451 9 131992120 [T/C] rs716548 9 131992861 [A/C] rs1411080 9 131993390 [T/G] rs12352047 9 131995919 [T/C] rs395119 9 131996071 [T/C] rs7048616 9 131996947 [A/G] rs9409314 9 131996962 [T/C] rs11790192 9 131998296 [A/G] rs17456493 9 131998330 [A/G] rs17440384 9 131999202 [A/G] rs11794903 9 131999768 [A/G] rs913775 9 131999876 [T/C] rs12237856 9 132002616 [T/C] rs10739745 9 132003513 [T/G] rs28365600 9 132004563 [T/C] rs17440439 9 132005835 [T/G] rs7023548 9 132008768 [T/C] rs4240433 9 132008809 [T/C] rs927926 9 132009096 [A/G] rs10116285 9 132009235 [A/G] rs12236289 9 132010706 [T/C] rs10988273 9 132015425 [A/G] rs7849837 9 132020431 [A/G] rs1556146 9 132022478 [T/C] rs17482519 9 132022920 [T/C] rs10988276 9 132024528 [A/G] rs10819484 9 132032637 [T/C] rs883342 9 132033760 [A/G] rs10988290 9 132035452 [A/C] rs12006343 9 132035764 [A/C] rs17456785 9 132036038 [A/G] rs17482630 9 132036052 [A/G] rs17482637 9 132036811 [T/C] rs7865568 9 132037179 [T/C] rs10988296 9 132041447 [T/C] rs10988298 9 132042502 [A/G] rs10819487 9 132042877 [T/C] rs7041313 9 132043158 [T/C] rs11794563 9 132044938 [T/C] NR_121587 LOC101929331 EXON Silent rs17456938 9 132046491 [A/G] NR_121587 LOC101929331 Silent rs17456945 9 132046625 [A/G] NR_121587 LOC101929331 Silent rs7039559 9 132047640 [A/G] NR_121587 LOC101929331 Silent rs7029664 9 132048953 [T/C] rs4366175 9 132049842 [A/C] rs17460265 9 132050461 [A/G] rs10988304 9 132053313 [T/C] rs7849290 9 132054282 [T/C] rs10819490 9 132056318 [T/C] rs17460287 9 132063575 [T/G] rs4599906 9 132063801 [A/G] rs4523365 9 132064209 [T/C] rs10988311 9 132071242 [T/G] rs7867597 9 132072646 [T/C] rs10819494 9 132073191 [T/C] rs11794580 9 132075016 [A/G] rs17517527 9 132075333 [T/C] rs10988319 9 132078047 [T/C] rs10988320 9 132078622 [T/C] rs10760607 9 132078777 [A/G] rs10819500 9 132081623 [A/G] rs11788098 9 132082564 [T/C] rs913770 9 132084621 [A/G] NR_149714 C9orf106 EXON Silent rs6478890 9 132085237 [A/G] rs7034728 9 132085293 [T/C] rs7850090 9 132085618 [A/G] rs913772 9 132085635 [T/C] rs4837357 9 132088190 [A/G] rs2282179 9 132090371 [T/C] rs10819503 9 132093021 [A/G] rs10988323 9 132093466 [T/C] rs17457362 9 132098060 [T/C] rs7859961 9 132098528 [A/G] rs10760611 9 132105143 [A/G] NR_120685,NR_120686 LINC01503,LINC01503 Silent,Silent rs10988334 9 132105533 [T/C] NR_120685,NR_120686 LINC01503,LINC01503 Silent,Silent rs17441302 9 132106034 [T/C] NR_120685,NR_120686 LINC01503,LINC01503 Silent,Silent rs17441316 9 132108247 [T/C] NR_120685,NR_120686 LINC01503,LINC01503 Silent,Silent rs4837360 9 132109628 [A/G] NR_120685,NR_120686 LINC01503,LINC01503 EXON Silent,Silent rs10988337 9 132111298 [A/G] rs17441351 9 132111630 [T/C] rs13295367 9 132113982 [A/G] rs10819506 9 132114326 [T/C] rs10988341 9 132115179 [A/G] rs2011978 9 132116060 [T/C] rs4507869 9 132127719 [T/C] rs7868621 9 132130971 [A/G] rs10988346 9 132131098 [A/G] rs28361625 9 132142411 [A/G] rs10819507 9 132145524 [A/C] rs3853486 9 132147812 [A/G] rs10819508 9 132147913 [T/C] rs7047362 9 132150169 [T/C] rs4090173 9 132150442 [A/G] rs11789821 9 132150995 [T/C] rs10819510 9 132155664 [A/G] rs12684332 9 132157537 [A/G] rs12345504 9 132159786 [T/G] rs10118507 9 132162419 [T/C] rs10118527 9 132162470 [T/C] rs4837362 9 132163254 [A/C] rs10988356 9 132167567 [T/C] rs9918961 9 132167952 [A/G] rs7048833 9 132168169 [A/G] rs7046787 9 132170673 [T/G] rs28361685 9 132173887 [A/G] rs17457947 9 132174235 [T/C] rs3928291 9 132176751 [A/G] rs17441968 9 132177003 [T/C] rs1105551 9 132177381 [T/C] rs1810914 9 132178213 [A/G] rs4837365 9 132180229 [T/C] rs10819516 9 132188431 [A/G] rs9657682 9 132191452 [T/C] rs4837366 9 132192986 [A/G] rs10988373 9 132194565 [T/C] rs914708 9 132196531 [T/G] rs1147331 9 132198135 [T/C] rs1147332 9 132198514 [T/C] rs1147338 9 132205249 [A/C] rs932988 9 132218356 [T/C] rs10988396 9 132232943 [T/G] rs12000279 9 132236094 [T/C] rs4837371 9 132236708 [T/C] rs7848479 9 132239272 [T/C] rs968477 9 132241861 [A/G] rs1220795 9 132253919 [A/G] NR_038955 LINC00963 Silent rs1220793 9 132254665 [A/G] NR_038955 LINC00963 Silent rs1220789 9 132257783 [T/C] NR_038955 LINC00963 Silent rs10819528 9 132260350 [A/G] NR_038955 LINC00963 Silent rs1780456 9 132268125 [A/G] NR_038955 LINC00963 Silent rs1721643 9 132270020 [A/G] NR_038955 LINC00963 Silent rs1721642 9 132271882 [T/C] NR_038955 LINC00963 Silent rs1780461 9 132273421 [A/G] NR_038955 LINC00963 Silent rs10988404 9 132275056 [T/C] NR_038955 LINC00963 Silent rs7043499 9 132280822 [T/C] rs10988407 9 132281601 [A/G] rs10429519 9 132281720 [A/G] rs4524899 9 132287630 [T/C] rs1533967 9 132287716 [A/G] rs3121625 9 132292954 [T/C] rs1780482 9 132293940 [T/C] rs1616208 9 132298733 [A/G] rs2498905 9 132302923 [A/C] rs2542250 9 132303601 [A/G] rs2542249 9 132305053 [T/C] rs12340960 9 132307433 [T/C] rs10988420 9 132308843 [T/C] rs12341313 9 132311524 [T/C] rs7867936 9 132314191 [A/G] rs7868056 9 132314273 [A/G] rs17469896 9 132315998 [A/G] rs10819541 9 132319215 [A/G] rs1220688 9 132321716 [T/C] rs1220687 9 132324366 [A/C] rs7851312 9 132334370 [T/C] rs1220680 9 132336394 [T/C] rs10819543 9 132339872 [A/G] rs4837389 9 132340037 [T/C] rs1220672 9 132342393 [A/C] rs17415618 9 132344026 [A/G] rs10988435 9 132344256 [A/G] rs10988437 9 132349265 [A/G] rs1220666 9 132351047 [A/G] rs1228439 9 132352178 [A/G] rs10988439 9 132352219 [T/G] rs1220651 9 132357836 [T/G] rs10819548 9 132363481 [T/C] rs1220658 9 132363874 [T/G] rs17416051 9 132365485 [T/G] rs2542242 9 132366836 [A/G] rs10988449 9 132370360 [T/C] rs1220701 9 132374013 [A/G] NM_001286796 NTMT1 Silent rs3213763 9 132375822 [T/C] NM_001286796,NM_199350 NTMT1,C9orf50 EXON Silent,Missense_R312Q rs10988452 9 132376859 [T/C] NM_001286796,NM_199350 NTMT1,C9orf50 Silent,Silent rs7850102 9 132380301 [A/G] NM_001286796,NM_199350 NTMT1,C9orf50 Silent,Silent rs4837393 9 132387665 [A/C] NM_001286796,NM_001286797 NTMT1,NTMT1 Silent,Silent rs1861782 9 132390239 [T/C] NM_001286796,NM_001286797,NM_001286801,NM_001286800,NM_001286798,NR_104596,NM_001286803,NM_001286802,NM_014064,NM_001286799 NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2900277 9 132394270 [T/G] NM_001286796,NM_001286797,NM_001286801,NM_001286800,NM_001286798,NR_104596,NM_001286803,NM_001286802,NM_014064,NM_001286799 NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2287296 9 132395245 [T/C] NM_001286796,NM_001286797,NM_001286801,NM_001286800,NM_001286798,NR_104596,NM_001286803,NM_001286802,NM_014064,NM_001286799 NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12335819 9 132395316 [T/C] NM_001286796,NM_001286797,NM_001286801,NM_001286800,NM_001286798,NR_104596,NM_001286803,NM_001286802,NM_014064,NM_001286799 NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9691 9 132397166 [A/G] NM_001286796,NM_001286797,NM_001286801,NM_001286800,NM_001286798,NR_104596,NM_001286803,NM_001286802,NM_014064,NM_001286799,NM_017873,NM_177999,NM_001202403 NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,ASB6,ASB6,ASB6 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3088095 9 132397239 [T/C] NM_001286796,NM_001286797,NM_001286801,NM_001286800,NM_001286798,NR_104596,NM_001286803,NM_001286802,NM_014064,NM_001286799,NM_017873,NM_177999,NM_001202403 NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,NTMT1,ASB6,ASB6,ASB6 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3739851 9 132400480 [A/G] NM_017873,NM_177999,NM_001202403 ASB6,ASB6,ASB6 EXON Synonymous_A285A,Silent,Synonymous_A256A rs4836665 9 132412706 [A/G] rs7866311 9 132414185 [A/G] rs7020887 9 132416836 [A/G] rs11793700 9 132416914 [A/G] rs16931378 9 132417166 [A/G] rs10124196 9 132417991 [T/C] rs10760632 9 132425233 [T/C] rs28562184 9 132427301 [T/C] rs10988467 9 132428927 [A/G] NM_016307 PRRX2 Silent rs7032080 9 132430178 [T/C] NM_016307 PRRX2 Silent rs12343788 9 132431625 [A/G] NM_016307 PRRX2 Silent rs7866070 9 132444099 [A/G] NM_016307 PRRX2 Silent rs10988469 9 132447093 [A/C] NM_016307 PRRX2 Silent rs10125991 9 132448019 [A/G] NM_016307 PRRX2 Silent rs10819557 9 132449756 [A/G] NM_016307 PRRX2 Silent rs7848375 9 132452336 [A/G] NM_016307 PRRX2 Silent rs894417 9 132458113 [A/G] NM_016307 PRRX2 Silent rs11794459 9 132463618 [A/G] NM_016307 PRRX2 Silent rs3844046 9 132465237 [T/C] NM_016307 PRRX2 Silent rs3861882 9 132465304 [T/C] NM_016307 PRRX2 Silent rs4836667 9 132465556 [T/C] NM_016307 PRRX2 Silent rs12685582 9 132474185 [A/C] NM_016307 PRRX2 Silent rs11791419 9 132478092 [A/G] NM_016307,NR_132102 PRRX2,PRRX2-AS1 Silent,Silent rs16931414 9 132486736 [T/C] rs16931419 9 132497550 [T/C] rs2302821 9 132501881 [A/C] NM_004878 PTGES EXON Silent rs11788591 9 132502801 [A/G] NM_004878 PTGES Silent rs4837404 9 132505659 [A/G] NM_004878 PTGES Silent rs10739757 9 132507910 [T/C] NM_004878 PTGES Silent rs10448290 9 132510366 [T/C] NM_004878 PTGES Silent rs10988493 9 132511956 [T/G] NM_004878 PTGES Silent rs2241271 9 132515081 [T/C] NM_004878 PTGES Silent rs11792431 9 132515247 [A/G] NM_004878 PTGES EXON Synonymous_A15A rs7872802 9 132515730 [A/G] rs3844048 9 132522269 [A/G] rs10118377 9 132523860 [A/G] rs7857431 9 132529504 [T/C] rs17418275 9 132537037 [T/C] rs4837412 9 132537865 [T/C] rs4837413 9 132539425 [T/C] rs11999731 9 132539989 [A/G] rs11998910 9 132541344 [T/C] rs11998940 9 132541486 [T/C] rs7873555 9 132546316 [T/C] rs10115114 9 132549493 [A/G] rs7867490 9 132549740 [T/G] rs16931454 9 132549985 [A/G] rs11793587 9 132552206 [T/G] rs7040096 9 132556974 [A/G] rs7025992 9 132557210 [T/C] rs7029757 9 132566666 [A/G] NM_001317893,NR_134027,NM_001317894,NR_133948,NM_014506,NR_134113 TOR1B,TOR1B,TOR1B,TOR1B,TOR1B,TOR1B EXON Silent,Silent,Silent,Silent,Silent,Silent rs10116248 9 132568500 [T/C] NM_001317893,NR_134027,NM_001317894,NR_133948,NM_014506,NR_134113 TOR1B,TOR1B,TOR1B,TOR1B,TOR1B,TOR1B Silent,Silent,Silent,Silent,Silent,Silent rs2287367 9 132572793 [A/C] NM_001317893,NR_134027,NM_001317894,NR_133948,NM_014506,NR_134113 TOR1B,TOR1B,TOR1B,TOR1B,TOR1B,TOR1B EXON Silent,Silent,Silent,Silent,Silent,Silent rs17418918 9 132573438 [T/G] NM_001317893,NR_134027,NM_001317894,NR_133948,NM_014506,NR_134113 TOR1B,TOR1B,TOR1B,TOR1B,TOR1B,TOR1B EXON Silent,Silent,Silent,Silent,Silent,Silent rs12634 9 132573536 [T/G] NM_001317893,NR_134027,NM_001317894,NR_133948,NM_014506,NR_134113 TOR1B,TOR1B,TOR1B,TOR1B,TOR1B,TOR1B EXON Silent,Silent,Silent,Silent,Silent,Silent rs13283584 9 132574862 [T/C] rs2296793 9 132585058 [A/G] NM_000113 TOR1A EXON Synonymous_A82A rs8113 9 132589606 [T/C] NM_016520 C9orf78 EXON Silent rs3818553 9 132591509 [A/G] NM_016520 C9orf78 EXON Synonymous_G251G rs3814547 9 132597021 [T/C] NM_016520 C9orf78 EXON Synonymous_E36E rs7019254 9 132601229 [T/C] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs11790814 9 132601903 [A/G] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs7042087 9 132602868 [T/C] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs7045022 9 132606981 [T/G] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs11999367 9 132614661 [A/G] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs2296786 9 132615077 [T/C] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs4288464 9 132616003 [A/G] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs10819567 9 132616209 [A/G] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs7048514 9 132616564 [A/G] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs12348760 9 132617148 [A/C] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs4836674 9 132618578 [T/C] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs7862315 9 132618807 [A/G] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs11788613 9 132619089 [T/G] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs2417150 9 132620224 [A/G] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs10819568 9 132620364 [T/C] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 EXON Synonymous_F57F,Synonymous_F57F,Synonymous_F57F rs1503375 9 132623293 [T/C] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 EXON Synonymous_D136D,Synonymous_D136D,Synonymous_D136D rs10115249 9 132623868 [T/C] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 EXON Synonymous_A158A,Synonymous_A158A,Synonymous_A158A rs4836675 9 132625352 [T/G] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs913316 9 132625818 [A/G] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs1108535 9 132629029 [T/C] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs880242 9 132629832 [A/G] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 Silent,Silent,Silent rs6478920 9 132631680 [T/C] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 EXON Synonymous_L456L,Synonymous_L456L,Synonymous_L456L rs735115 9 132637712 [A/G] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 EXON Synonymous_A724A,Synonymous_A724A,Synonymous_A724A rs3739858 9 132642848 [T/C] NM_001008563,NM_001110303,NM_006676 USP20,USP20,USP20 EXON Silent,Silent,Silent rs7849898 9 132644138 [T/C] rs1503372 9 132649662 [A/G] NM_015033 FNBP1 EXON Silent rs1057888 9 132649857 [T/C] NM_015033 FNBP1 EXON Silent rs13295392 9 132655864 [T/G] NM_015033 FNBP1 Silent rs10760644 9 132657519 [T/G] NM_015033 FNBP1 Silent rs1023000 9 132662786 [T/C] NM_015033,NM_001363755 FNBP1,FNBP1 EXON Missense_S490N,Missense_S461N rs7044285 9 132666628 [T/C] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs10739766 9 132673694 [T/C] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs2295952 9 132681784 [T/C] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs7022657 9 132698515 [T/C] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs7870884 9 132707164 [T/C] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs17519205 9 132720770 [A/G] NM_015033,NM_001363755 FNBP1,FNBP1 EXON Synonymous_S136S,Synonymous_S136S rs2900284 9 132726275 [T/C] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs4837437 9 132735246 [T/C] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs2102209 9 132753534 [T/C] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs7033372 9 132756251 [A/G] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs2417202 9 132758347 [A/G] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs1393904 9 132758467 [A/G] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs1322671 9 132759808 [A/C] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs10114099 9 132766685 [T/C] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs2417192 9 132771351 [A/G] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs10760653 9 132777024 [T/C] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs570640 9 132785156 [A/G] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs1923664 9 132786313 [A/C] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs806861 9 132787528 [A/G] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs12353358 9 132792272 [T/C] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs1923662 9 132803206 [A/C] NM_015033,NM_001363755 FNBP1,FNBP1 Silent,Silent rs10819596 9 132829354 [T/G] NM_001136557,NM_001136558,NM_020960,NM_001287346 GPR107,GPR107,GPR107,GPR107 Silent,Silent,Silent,Silent rs2065159 9 132830460 [A/G] NM_001136557,NM_001136558,NM_020960,NM_001287346 GPR107,GPR107,GPR107,GPR107 Silent,Silent,Silent,Silent rs12380103 9 132837130 [A/G] NM_001136557,NM_001136558,NM_020960,NM_001287346 GPR107,GPR107,GPR107,GPR107 Silent,Silent,Silent,Silent rs10739772 9 132837275 [A/G] NM_001136557,NM_001136558,NM_020960,NM_001287346 GPR107,GPR107,GPR107,GPR107 Silent,Silent,Silent,Silent rs7848363 9 132840968 [A/G] NM_001136557,NM_001136558,NM_020960,NM_001287346 GPR107,GPR107,GPR107,GPR107 Silent,Silent,Silent,Silent rs2159640 9 132849126 [T/C] NM_001136557,NM_001136558,NM_020960,NM_001287346 GPR107,GPR107,GPR107,GPR107 Silent,Silent,Silent,Silent rs12346450 9 132850277 [A/G] NM_001136557,NM_001136558,NM_020960,NM_001287346 GPR107,GPR107,GPR107,GPR107 Silent,Silent,Silent,Silent rs2286792 9 132861672 [T/G] NM_001136557,NM_001136558,NM_020960,NM_001287346 GPR107,GPR107,GPR107,GPR107 Silent,Silent,Silent,Silent rs11788668 9 132869204 [T/C] NM_001136557,NM_001136558,NM_020960,NM_001287346 GPR107,GPR107,GPR107,GPR107 Silent,Silent,Silent,Silent rs10988593 9 132869344 [A/G] NM_001136557,NM_001136558,NM_020960,NM_001287346 GPR107,GPR107,GPR107,GPR107 Silent,Silent,Silent,Silent rs7863436 9 132870692 [T/C] NM_001136557,NM_001136558,NM_020960,NM_001287346 GPR107,GPR107,GPR107,GPR107 Silent,Silent,Silent,Silent rs4837460 9 132872686 [A/G] NM_001136557,NM_001136558,NM_020960,NM_001287346 GPR107,GPR107,GPR107,GPR107 EXON Synonymous_L448L,Synonymous_L448L,Silent,Silent rs7851378 9 132882000 [A/G] NM_001136557,NM_001136558,NM_020960,NM_001287346 GPR107,GPR107,GPR107,GPR107 Silent,Silent,Silent,Silent rs7851530 9 132882141 [A/G] NM_001136557,NM_001136558,NM_020960,NM_001287346 GPR107,GPR107,GPR107,GPR107 Silent,Silent,Silent,Silent rs1003415 9 132895950 [T/C] NM_001136557,NM_001136558,NM_020960 GPR107,GPR107,GPR107 Silent,Silent,Silent rs12344508 9 132897036 [A/G] NM_001136557,NM_001136558,NM_020960 GPR107,GPR107,GPR107 Silent,Silent,Silent rs1003416 9 132897231 [A/G] NM_001136557,NM_001136558,NM_020960 GPR107,GPR107,GPR107 Silent,Silent,Silent rs2240912 9 132897736 [A/G] NM_001136557,NM_001136558,NM_020960 GPR107,GPR107,GPR107 EXON Silent,Silent,Silent rs2240913 9 132898193 [A/G] NM_001136557,NM_001136558,NM_020960 GPR107,GPR107,GPR107 EXON Silent,Silent,Silent rs1306 9 132900076 [T/C] NM_001136557,NM_001136558,NM_020960 GPR107,GPR107,GPR107 EXON Silent,Silent,Silent rs10819601 9 132901403 [T/C] NM_001136557,NM_001136558,NM_020960 GPR107,GPR107,GPR107 EXON Silent,Silent,Silent rs10988603 9 132901507 [A/G] NM_001136557,NM_001136558,NM_020960 GPR107,GPR107,GPR107 EXON Silent,Silent,Silent rs12341889 9 132902152 [A/G] NM_001136557,NM_001136558,NM_020960 GPR107,GPR107,GPR107 EXON Silent,Silent,Silent rs8503 9 132902219 [T/C] NM_001136557,NM_001136558,NM_020960 GPR107,GPR107,GPR107 EXON Silent,Silent,Silent rs6478949 9 132902487 [T/G] rs17221008 9 132906486 [T/C] NR_135124 LOC401554 EXON Silent rs7850761 9 132911491 [T/C] rs7851165 9 132911947 [A/G] rs7866942 9 132912105 [T/C] rs12347960 9 132912150 [A/G] rs4836691 9 132914712 [A/G] rs13290443 9 132915287 [T/C] rs10819605 9 132917235 [A/C] rs1860641 9 132919230 [T/C] rs7034452 9 132919453 [T/C] rs10988617 9 132920576 [T/C] rs12352544 9 132920697 [T/C] rs10760659 9 132923772 [A/C] rs11789529 9 132926691 [T/C] rs10988625 9 132927568 [A/G] rs12378342 9 132930343 [T/C] rs7041484 9 132933436 [T/C] rs3780708 9 132935951 [T/C] NM_014286 NCS1 Silent rs4837479 9 132940007 [T/C] NM_014286 NCS1 Silent rs3780711 9 132943043 [T/C] NM_014286 NCS1 Silent rs7849345 9 132944545 [T/C] NM_014286 NCS1 Silent rs10819610 9 132946615 [T/G] NM_014286 NCS1 Silent rs3824544 9 132948550 [T/C] NM_014286 NCS1 Silent rs740918 9 132955172 [A/G] NM_014286 NCS1 Silent rs10819611 9 132955453 [T/C] NM_014286 NCS1 Silent rs1009502 9 132956229 [A/G] NM_014286 NCS1 Silent rs758850 9 132957523 [A/G] NM_014286 NCS1 Silent rs1342043 9 132958305 [T/C] NM_014286 NCS1 Silent rs887535 9 132963129 [A/G] NM_014286,NM_001128826 NCS1,NCS1 Silent,Silent rs7024495 9 132967196 [A/G] NM_014286,NM_001128826 NCS1,NCS1 Silent,Silent rs7024934 9 132967288 [A/G] NM_014286,NM_001128826 NCS1,NCS1 Silent,Silent rs868964 9 132971820 [A/G] NM_014286,NM_001128826 NCS1,NCS1 Silent,Silent rs947513 9 132973988 [A/G] NM_014286,NM_001128826 NCS1,NCS1 Silent,Silent rs7848440 9 132977438 [T/C] NM_014286,NM_001128826 NCS1,NCS1 Silent,Silent rs4240447 9 132978477 [A/G] NM_014286,NM_001128826 NCS1,NCS1 Silent,Silent rs1001742 9 132979088 [A/G] NM_014286,NM_001128826 NCS1,NCS1 Silent,Silent rs3829905 9 132985111 [T/C] NM_014286,NM_001128826 NCS1,NCS1 Silent,Silent rs4524901 9 132985418 [T/A] NM_014286,NM_001128826 NCS1,NCS1 EXON Missense_I152F,Missense_I134F rs2277200 9 132988709 [T/G] NM_014286,NM_001128826 NCS1,NCS1 EXON Synonymous_G172G,Synonymous_G154G rs7873936 9 132993162 [A/G] NM_014286,NM_001128826 NCS1,NCS1 Silent,Silent rs7852859 9 132995160 [A/G] NM_014286,NM_001128826 NCS1,NCS1 Silent,Silent rs709611 9 132998359 [T/C] NM_014286,NM_001128826 NCS1,NCS1 EXON Silent,Silent rs7847694 9 132999182 [T/C] NM_014286,NM_001128826 NCS1,NCS1 EXON Silent,Silent rs7867364 9 133000282 [T/C] rs7863731 9 133002805 [T/C] rs7867693 9 133003804 [A/G] rs10988653 9 133006474 [T/C] rs7866994 9 133009150 [T/C] rs4553010 9 133011232 [A/G] rs7026795 9 133013233 [A/G] rs7046248 9 133013484 [T/G] rs13302591 9 133014637 [A/G] rs10988659 9 133014733 [T/C] rs7045878 9 133019198 [T/C] rs10115217 9 133019752 [T/C] rs10119818 9 133021887 [A/G] rs10819626 9 133025756 [A/C] rs7028995 9 133025949 [T/C] rs4837486 9 133037273 [T/C] NM_001291815 HMCN2 Silent rs7870070 9 133039461 [A/G] NM_001291815 HMCN2 Silent rs10988672 9 133039956 [T/C] NM_001291815 HMCN2 Silent rs10988675 9 133042138 [A/G] NM_001291815 HMCN2 Silent rs7866146 9 133045648 [A/G] NM_001291815 HMCN2 Silent rs6478957 9 133048501 [A/G] NM_001291815 HMCN2 EXON Missense_R175H rs1105621 9 133050233 [T/C] NM_001291815 HMCN2 Silent rs947509 9 133050928 [T/C] NM_001291815 HMCN2 Silent rs947510 9 133051110 [T/C] NM_001291815 HMCN2 Silent rs1935344 9 133054868 [T/G] NM_001291815 HMCN2 Silent rs4260979 9 133055949 [T/C] NM_001291815 HMCN2 Silent rs947507 9 133057805 [T/C] NM_001291815 HMCN2 Silent rs10988681 9 133057987 [A/G] NM_001291815 HMCN2 EXON Missense_N276S rs12555056 9 133059626 [A/G] NM_001291815 HMCN2 Silent rs10819633 9 133070628 [T/G] NM_001291815 HMCN2 Silent rs6478961 9 133071918 [T/C] NM_001291815 HMCN2 Silent rs28972384 9 133072863 [A/G] NM_001291815 HMCN2 Silent rs28970815 9 133223308 [T/G] NM_001291815 HMCN2 Silent rs914977 9 133226582 [A/G] NM_001291815 HMCN2 Silent rs914976 9 133229311 [T/C] NM_001291815 HMCN2 Silent rs2027064 9 133234555 [A/G] NM_001291815 HMCN2 Silent rs7047329 9 133239496 [T/C] NM_001291815 HMCN2 Silent rs4066676 9 133241082 [A/G] NM_001291815 HMCN2 EXON Synonymous_P1600P rs4579578 9 133241327 [T/G] NM_001291815 HMCN2 EXON Missense_A1633S rs7874077 9 133242154 [T/G] NM_001291815 HMCN2 Silent rs914981 9 133245991 [A/G] NM_001291815 HMCN2 Silent rs1316391 9 133246083 [A/G] NM_001291815 HMCN2 Silent rs11243875 9 133246381 [T/C] NM_001291815 HMCN2 EXON Synonymous_P1809P rs9776338 9 133248803 [A/G] NM_001291815 HMCN2 Silent rs7031579 9 133250275 [T/C] NM_001291815 HMCN2 Silent rs11244043 9 133251986 [T/C] NM_001291815 HMCN2 EXON Missense_L2110P rs7020021 9 133252969 [T/C] NM_001291815 HMCN2 Silent rs10901268 9 133253482 [T/C] NM_001291815 HMCN2 Silent rs7855331 9 133262821 [A/G] NM_001291815 HMCN2 Silent rs11244127 9 133264096 [A/G] NM_001291815 HMCN2 Silent rs4372050 9 133271928 [T/C] NM_001291815 HMCN2 Silent rs4573325 9 133274265 [A/C] NM_001291815 HMCN2 Silent rs11244165 9 133274806 [A/G] NM_001291815 HMCN2 Silent rs885531 9 133276075 [A/G] NM_001291815 HMCN2 Silent rs914978 9 133277641 [T/C] NM_001291815 HMCN2 Silent rs10901300 9 133279395 [T/C] NM_001291815 HMCN2 Silent rs10736862 9 133283255 [A/G] NM_001291815 HMCN2 Silent rs6597658 9 133283580 [A/G] NM_001291815 HMCN2 Silent rs10793975 9 133284310 [A/G] NM_001291815 HMCN2 EXON Synonymous_P3732P rs10901311 9 133285049 [T/C] NM_001291815 HMCN2 Silent rs4740391 9 133287097 [A/G] NM_001291815 HMCN2 Silent rs11244241 9 133288738 [A/G] NM_001291815 HMCN2 Silent rs7044220 9 133289174 [A/G] NM_001291815 HMCN2 Silent rs7049027 9 133290501 [A/G] NM_001291815 HMCN2 Silent rs10901326 9 133292993 [A/G] NM_001291815 HMCN2 Silent rs13294886 9 133294244 [A/G] NM_001291815 HMCN2 EXON Missense_A3792T rs12352066 9 133294905 [A/G] NM_001291815 HMCN2 Silent rs2282217 9 133307984 [T/C] NM_001291815 HMCN2 Silent rs2282218 9 133308063 [A/G] NM_001291815 HMCN2 Silent rs12342208 9 133310815 [T/C] rs4237122 9 133313115 [A/G] rs12337532 9 133314496 [T/C] rs928518 9 133318751 [T/G] rs11244367 9 133319473 [T/G] rs10901047 9 133323675 [T/C] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs11243372 9 133324400 [A/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs4740158 9 133325472 [T/C] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs914983 9 133326213 [A/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs1653332 9 133328969 [A/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs7860909 9 133331226 [A/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs1215985 9 133335415 [T/C] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs914971 9 133338393 [T/C] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs590086 9 133343659 [T/C] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs12551145 9 133343744 [A/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs10901072 9 133346226 [T/C] NM_000050,NM_054012 ASS1,ASS1 EXON Synonymous_H167H,Synonymous_H167H rs504752 9 133350319 [A/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs1215972 9 133350608 [A/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs476067 9 133351106 [A/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs540140 9 133355371 [T/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs596317 9 133356805 [T/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs480313 9 133357294 [T/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs506626 9 133359725 [T/C] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs474330 9 133360892 [A/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs17147023 9 133361010 [T/C] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs666971 9 133362055 [A/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs12375699 9 133365094 [T/C] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs634432 9 133367368 [T/C] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs7018779 9 133367704 [T/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs544701 9 133372383 [A/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs2282219 9 133376153 [A/G] NM_000050,NM_054012 ASS1,ASS1 Silent,Silent rs10793902 9 133377910 [T/C] rs2991274 9 133387709 [A/G] rs13301412 9 133388232 [A/G] rs612380 9 133392659 [T/C] rs598208 9 133393510 [A/G] rs618962 9 133395609 [T/G] rs4740339 9 133400958 [A/C] rs7874812 9 133405176 [A/G] rs7849694 9 133410844 [A/G] rs944605 9 133415084 [A/G] rs4740193 9 133421313 [A/C] rs4740194 9 133422828 [T/C] rs944604 9 133424020 [T/C] rs1560532 9 133427274 [T/C] rs11243759 9 133427524 [A/C] rs2313200 9 133429006 [A/G] rs10793932 9 133436730 [T/C] rs4740347 9 133439577 [T/C] rs7030440 9 133440620 [A/G] rs10901185 9 133441389 [A/G] rs10793939 9 133442778 [T/C] rs4740196 9 133453327 [A/C] NR_027440 LOC100272217 EXON Silent rs7021782 9 133468780 [A/G] NM_003934 FUBP3 Silent rs10901226 9 133483217 [A/G] NM_003934 FUBP3 Silent rs11243976 9 133488494 [A/G] NM_003934 FUBP3 Silent rs7040341 9 133490496 [T/G] NM_003934 FUBP3 Silent rs11794652 9 133496402 [A/G] NM_003934 FUBP3 Silent rs2304808 9 133510021 [T/C] NM_003934 FUBP3 Silent rs11244092 9 133526315 [T/C] rs7872037 9 133527975 [A/C] rs7028896 9 133532160 [T/C] rs1890599 9 133537672 [A/G] rs2313583 9 133539126 [A/G] rs3808825 9 133539661 [A/G] rs2277186 9 133543980 [T/G] NM_021619 PRDM12 Silent rs10901270 9 133545578 [T/G] NM_021619 PRDM12 Silent rs10120700 9 133548589 [A/C] NM_021619 PRDM12 Silent rs1545229 9 133550133 [T/C] NM_021619 PRDM12 Silent rs10751506 9 133552145 [A/G] NM_021619 PRDM12 Silent rs894243 9 133553187 [T/C] NM_021619 PRDM12 Silent rs7021384 9 133553993 [T/C] NM_021619 PRDM12 EXON Synonymous_P216P rs7024667 9 133554189 [T/C] NM_021619 PRDM12 Silent rs2855159 9 133566997 [A/C] rs7852487 9 133571587 [T/C] NM_001282709,NR_104230,NM_001282708,NM_014285 EXOSC2,EXOSC2,EXOSC2,EXOSC2 Silent,Silent,Silent,Silent rs2269337 9 133572684 [A/G] NM_001282709,NR_104230,NM_001282708,NM_014285 EXOSC2,EXOSC2,EXOSC2,EXOSC2 Silent,Silent,Silent,Silent rs12353537 9 133573164 [A/G] NM_001282709,NR_104230,NM_001282708,NM_014285 EXOSC2,EXOSC2,EXOSC2,EXOSC2 Silent,Silent,Silent,Silent rs7869951 9 133588943 [T/C] rs2583839 9 133593939 [A/G] NM_007313 ABL1 Silent rs4740359 9 133595219 [A/G] NM_007313 ABL1 Silent rs10751508 9 133608116 [T/C] NM_007313 ABL1 Silent rs10793967 9 133612557 [A/G] NM_007313 ABL1 Silent rs2253084 9 133621773 [T/C] NM_007313 ABL1 Silent rs4740363 9 133629184 [A/G] NM_007313 ABL1 Silent rs4740366 9 133630622 [A/G] NM_007313 ABL1 Silent rs2855171 9 133638943 [T/C] NM_007313 ABL1 Silent rs4990084 9 133646592 [T/C] NM_007313 ABL1 Silent rs2855172 9 133651648 [A/C] NM_007313 ABL1 Silent rs2855179 9 133657281 [A/G] NM_007313 ABL1 Silent rs11244139 9 133660799 [T/C] NM_007313 ABL1 Silent rs11244140 9 133663058 [T/C] NM_007313 ABL1 Silent rs7026988 9 133667899 [T/C] NM_007313 ABL1 Silent rs12341805 9 133668114 [T/C] NM_007313 ABL1 Silent rs10901285 9 133670874 [A/G] NM_007313 ABL1 Silent rs4740372 9 133675739 [A/G] NM_007313 ABL1 Silent rs11244147 9 133677168 [T/G] NM_007313 ABL1 Silent rs17147263 9 133696125 [T/C] NM_007313 ABL1 Silent rs2314342 9 133707362 [A/G] NM_007313 ABL1 Silent rs6597642 9 133725767 [A/G] NM_007313,NM_005157 ABL1,ABL1 Silent,Silent rs10901294 9 133732752 [T/C] NM_007313,NM_005157 ABL1,ABL1 Silent,Silent rs3824400 9 133734075 [T/C] NM_007313,NM_005157 ABL1,ABL1 Silent,Silent rs2855194 9 133735644 [A/G] NM_007313,NM_005157 ABL1,ABL1 Silent,Silent rs11244164 9 133736116 [A/G] NM_007313,NM_005157 ABL1,ABL1 Silent,Silent rs7856784 9 133738074 [T/C] NM_007313,NM_005157 ABL1,ABL1 Silent,Silent rs3780282 9 133743654 [A/G] NM_007313,NM_005157 ABL1,ABL1 Silent,Silent rs7848941 9 133744672 [A/G] NM_007313,NM_005157 ABL1,ABL1 Silent,Silent rs7851994 9 133749848 [T/C] NM_007313,NM_005157 ABL1,ABL1 Silent,Silent rs2227985 9 133755528 [A/G] NM_007313,NM_005157 ABL1,ABL1 EXON Synonymous_E518E,Synonymous_E499E rs12005009 9 133755754 [T/C] NM_007313,NM_005157 ABL1,ABL1 Silent,Silent rs12351264 9 133756710 [T/C] NM_007313,NM_005157 ABL1,ABL1 Silent,Silent rs2229067 9 133760592 [T/C] NM_007313,NM_005157 ABL1,ABL1 EXON Missense_S991L,Missense_S972L rs1056171 9 133761001 [A/G] NM_007313,NM_005157 ABL1,ABL1 EXON Synonymous_P1127P,Synonymous_P1108P rs11991 9 133762558 [T/C] NM_007313,NM_005157 ABL1,ABL1 EXON Silent,Silent rs7457 9 133762826 [T/C] NM_007313,NM_005157 ABL1,ABL1 EXON Silent,Silent rs9328548 9 133767980 [T/C] rs7034278 9 133769786 [T/C] NM_198180 QRFP Silent rs7040543 9 133770017 [A/C] NM_198180 QRFP Silent rs7865017 9 133770222 [T/C] NM_198180 QRFP Silent rs7853654 9 133770270 [A/G] NM_198180 QRFP Silent rs7026476 9 133772910 [T/C] rs2297091 9 133775857 [T/C] rs11789517 9 133777993 [T/G] NM_032843,NM_001145106 FIBCD1,FIBCD1 EXON Silent,Silent rs11791437 9 133778117 [T/C] NM_032843,NM_001145106 FIBCD1,FIBCD1 EXON Silent,Silent rs3802347 9 133779020 [A/G] NM_032843,NM_001145106 FIBCD1,FIBCD1 EXON Silent,Silent rs11792889 9 133779448 [A/G] NM_032843,NM_001145106 FIBCD1,FIBCD1 EXON Silent,Silent rs6597650 9 133787225 [A/G] NM_032843,NM_001145106 FIBCD1,FIBCD1 EXON Synonymous_D300D,Synonymous_D300D rs10901304 9 133789420 [A/G] NM_032843,NM_001145106 FIBCD1,FIBCD1 Silent,Silent rs3847195 9 133790521 [A/C] NM_032843,NM_001145106 FIBCD1,FIBCD1 Silent,Silent rs11793972 9 133793102 [T/C] NM_032843,NM_001145106 FIBCD1,FIBCD1 Silent,Silent rs13293102 9 133795610 [T/C] NM_032843,NM_001145106 FIBCD1,FIBCD1 Silent,Silent rs6597655 9 133796694 [T/C] NM_032843,NM_001145106 FIBCD1,FIBCD1 Silent,Silent rs7035023 9 133797557 [T/C] NM_032843,NM_001145106 FIBCD1,FIBCD1 Silent,Silent rs7864465 9 133808080 [A/G] NM_032843,NM_001145106 FIBCD1,FIBCD1 Silent,Silent rs11244202 9 133809775 [A/C] NM_032843,NM_001145106 FIBCD1,FIBCD1 Silent,Silent rs10793974 9 133810848 [A/G] NM_032843,NM_001145106 FIBCD1,FIBCD1 Silent,Silent rs12343454 9 133816023 [A/G] rs10901309 9 133823473 [T/C] rs7026302 9 133828475 [A/G] rs4568653 9 133828515 [A/G] rs10901310 9 133832469 [A/G] rs12346096 9 133848437 [A/G] rs9886861 9 133849498 [T/C] rs9886826 9 133849547 [T/C] rs10901314 9 133852742 [T/C] rs12344376 9 133856814 [T/G] rs7048958 9 133856962 [A/G] rs17147386 9 133857758 [T/C] rs2178107 9 133858122 [A/G] rs10114591 9 133860275 [A/G] rs6597668 9 133861632 [A/G] rs7862053 9 133862285 [T/C] rs10901316 9 133862958 [A/C] rs12005819 9 133863770 [A/G] rs7852743 9 133865384 [T/C] rs7861384 9 133865674 [A/G] rs11795033 9 133865861 [T/C] rs12683313 9 133868398 [T/C] rs11244233 9 133872871 [T/C] rs11244234 9 133873991 [A/G] rs10118337 9 133874462 [T/G] rs10116370 9 133874568 [T/C] rs11998813 9 133874685 [T/G] rs3857985 9 133876113 [A/G] rs10901317 9 133876911 [T/C] rs13286358 9 133884676 [T/C] NM_006059 LAMC3 EXON Synonymous_C25C rs11244245 9 133886042 [T/C] NM_006059 LAMC3 Silent rs3808813 9 133886137 [T/C] NM_006059 LAMC3 Silent rs869936 9 133887901 [T/C] NM_006059 LAMC3 Silent rs915401 9 133888771 [A/G] NM_006059 LAMC3 Silent rs881676 9 133891847 [A/G] NM_006059 LAMC3 Silent rs4588908 9 133897119 [T/C] NM_006059 LAMC3 Silent rs10793982 9 133906060 [T/C] NM_006059 LAMC3 Silent rs3780280 9 133906250 [A/G] NM_006059 LAMC3 Silent rs2275134 9 133907229 [T/C] NM_006059 LAMC3 Silent rs2275133 9 133907539 [A/G] NM_006059 LAMC3 EXON Synonymous_V262V rs3808810 9 133908753 [A/G] NM_006059 LAMC3 Silent rs3780279 9 133908961 [A/C] NM_006059 LAMC3 Silent rs2275131 9 133911706 [T/C] NM_006059 LAMC3 EXON Synonymous_A321A rs3780275 9 133913434 [A/G] NM_006059 LAMC3 Silent rs2293518 9 133914570 [A/G] NM_006059 LAMC3 EXON Synonymous_T406T rs2293520 9 133917277 [A/G] NM_006059 LAMC3 Silent rs4740396 9 133917807 [T/C] NM_006059 LAMC3 Silent rs1414402 9 133922072 [T/C] NM_006059 LAMC3 Silent rs869457 9 133924451 [T/C] NM_006059 LAMC3 EXON Missense_P522S rs11793535 9 133925813 [T/C] NM_006059 LAMC3 Silent rs10793985 9 133927286 [A/G] NM_006059 LAMC3 Silent rs10901333 9 133927878 [A/G] NM_006059 LAMC3 EXON Missense_E544G rs10901336 9 133935704 [T/G] NM_006059 LAMC3 Silent rs6597674 9 133937944 [A/G] NM_006059 LAMC3 Silent rs4740402 9 133938973 [A/G] NM_006059 LAMC3 Silent rs4740403 9 133938981 [A/G] NM_006059 LAMC3 Silent rs7863187 9 133940735 [T/C] NM_006059 LAMC3 Silent rs12553829 9 133942844 [T/C] NM_006059 LAMC3 Silent rs10901344 9 133946909 [A/G] NM_006059 LAMC3 EXON Synonymous_G1036G rs7858204 9 133947345 [A/G] NM_006059 LAMC3 Silent rs2275140 9 133948049 [A/G] NM_006059 LAMC3 EXON Missense_S1082G rs13301105 9 133951180 [A/G] NM_006059 LAMC3 Silent rs3818800 9 133951230 [T/C] NM_006059 LAMC3 EXON Synonymous_T1169T rs7860487 9 133957759 [T/C] NM_006059 LAMC3 Silent rs7873372 9 133958148 [T/C] NM_006059 LAMC3 Silent rs1889749 9 133958298 [T/G] NM_006059 LAMC3 Silent rs7024108 9 133962930 [T/C] NM_006059 LAMC3 EXON Missense_T1433M rs4740412 9 133963008 [A/G] NM_006059 LAMC3 EXON Missense_R1459Q rs818056 9 133967240 [T/C] NM_006059 LAMC3 EXON Silent rs818055 9 133967510 [A/C] NM_006059 LAMC3 EXON Silent rs752929 9 133968546 [A/G] rs818051 9 133970178 [T/C] rs748697 9 133979352 [A/G] NM_001185095,NM_001185096,NR_033701,NM_031426 AIF1L,AIF1L,AIF1L,AIF1L Silent,Silent,Silent,Silent rs2872823 9 133981491 [T/G] NM_001185095,NM_001185096,NR_033701,NM_031426 AIF1L,AIF1L,AIF1L,AIF1L Silent,Silent,Silent,Silent rs2315075 9 133981629 [T/C] NM_001185095,NM_001185096,NR_033701,NM_031426 AIF1L,AIF1L,AIF1L,AIF1L EXON Missense_C50R,Silent,Silent,Silent rs353525 9 133987060 [A/G] NM_001185095,NM_001185096,NR_033701,NM_031426 AIF1L,AIF1L,AIF1L,AIF1L Silent,Silent,Silent,Silent rs353514 9 133995353 [T/C] NM_001185095,NM_001185096,NR_033701,NM_031426 AIF1L,AIF1L,AIF1L,AIF1L Silent,Silent,Silent,Silent rs353512 9 133996184 [T/C] NM_001185095,NM_001185096,NR_033701,NM_031426 AIF1L,AIF1L,AIF1L,AIF1L EXON Silent,Silent,Silent,Silent rs7855960 9 133997382 [A/G] NM_001185095,NM_001185096,NR_033701,NM_031426 AIF1L,AIF1L,AIF1L,AIF1L EXON Silent,Silent,Silent,Silent rs3736957 9 134004912 [A/C] NM_005085,NM_001318324 NUP214,NUP214 Silent,Silent rs7861678 9 134012922 [T/C] NM_005085,NM_001318324 NUP214,NUP214 Silent,Silent rs928675 9 134014000 [A/G] NM_005085,NM_001318324 NUP214,NUP214 Silent,Silent rs102993 9 134015072 [T/G] NM_005085,NM_001318324 NUP214,NUP214 Silent,Silent rs2281901 9 134016121 [T/C] NM_005085,NM_001318324 NUP214,NUP214 Silent,Silent rs103612 9 134020092 [T/C] NM_005085,NM_001318324 NUP214,NUP214 EXON Missense_P574S,Missense_P574S rs7859782 9 134025174 [T/C] NM_005085,NM_001318324 NUP214,NUP214 Silent,Silent rs11244305 9 134025595 [A/G] NM_005085,NM_001318324 NUP214,NUP214 Silent,Silent rs4740418 9 134038821 [T/C] NM_005085,NM_001318324 NUP214,NUP214 Silent,Silent rs2274427 9 134064345 [T/C] NM_005085,NM_001318324 NUP214,NUP214 Silent,Silent rs10901356 9 134067474 [A/C] NM_005085,NM_001318324,NM_001318325 NUP214,NUP214,NUP214 Silent,Silent,Silent rs12347273 9 134089755 [A/G] NM_005085,NM_001318324,NM_001318325 NUP214,NUP214,NUP214 Silent,Silent,Silent rs4740420 9 134096015 [T/C] NM_005085,NM_001318324,NM_001318325 NUP214,NUP214,NUP214 Silent,Silent,Silent rs12341218 9 134105235 [A/G] NM_005085,NM_001318324,NM_001318325 NUP214,NUP214,NUP214 Silent,Silent,Silent rs11790462 9 134107816 [T/C] NM_005085,NM_001318324,NM_001318325 NUP214,NUP214,NUP214 Silent,Silent,Silent rs11244336 9 134118740 [A/G] rs7022116 9 134130544 [T/C] rs9966 9 134136248 [A/G] NM_033387 FAM78A EXON Synonymous_Y271Y rs2281899 9 134136416 [A/G] NM_033387 FAM78A EXON Synonymous_L215L rs352952 9 134136515 [A/G] NM_033387 FAM78A EXON Synonymous_N182N rs352951 9 134136677 [A/G] NM_033387 FAM78A EXON Synonymous_D128D rs3739508 9 134139458 [A/C] NM_033387 FAM78A Silent rs7024383 9 134141129 [A/G] NM_033387 FAM78A Silent rs7041339 9 134142444 [T/C] NM_033387 FAM78A Silent rs10793992 9 134149338 [A/G] NM_033387 FAM78A Silent rs10901359 9 134149767 [T/C] NM_033387 FAM78A Silent rs4740427 9 134151863 [T/G] NM_033387 FAM78A EXON Silent rs10901363 9 134156043 [T/C] rs11244354 9 134162558 [T/C] rs11793913 9 134164454 [T/C] rs7041276 9 134165248 [T/C] NM_032728 PLPP7 EXON Silent rs2986608 9 134169176 [A/C] NM_032728 PLPP7 Silent rs2483469 9 134169616 [T/C] NM_032728 PLPP7 Silent rs2966332 9 134183379 [T/C] NM_032728 PLPP7 EXON Missense_T174M rs2986606 9 134183503 [T/C] NM_032728 PLPP7 EXON Synonymous_R215R rs2483476 9 134183913 [A/G] NM_032728 PLPP7 EXON Silent rs2483477 9 134184191 [T/G] NM_032728 PLPP7 EXON Silent rs913218 9 134195966 [T/C] rs2986599 9 134198900 [A/G] rs10751521 9 134209707 [T/C] rs4740438 9 134212002 [A/G] rs522464 9 134214383 [A/C] rs2966373 9 134222085 [T/C] rs11243356 9 134223191 [T/C] rs2050243 9 134225572 [A/G] rs11243362 9 134228471 [A/C] rs7852711 9 134233268 [A/G] rs4740227 9 134233569 [A/G] rs10901052 9 134237148 [A/G] rs11243375 9 134238611 [T/C] rs10901054 9 134240052 [A/C] rs6597494 9 134247571 [A/G] rs500446 9 134254451 [T/C] rs2483468 9 134256675 [A/G] rs542305 9 134258779 [A/G] rs517961 9 134272423 [T/C] rs2994040 9 134290898 [A/G] rs17147857 9 134301996 [A/G] rs4740238 9 134308491 [A/G] NM_013318 PRRC2B Silent rs7049110 9 134313625 [A/G] NM_013318 PRRC2B Silent rs2966344 9 134314882 [T/C] NM_013318 PRRC2B Silent rs2994060 9 134316004 [A/G] NM_013318 PRRC2B Silent rs4740240 9 134320354 [T/G] NM_013318 PRRC2B Silent rs2994064 9 134323240 [A/C] NM_013318 PRRC2B Silent rs2994066 9 134326950 [A/G] NM_013318 PRRC2B Silent rs7357766 9 134334733 [T/C] NM_013318 PRRC2B EXON Missense_P465L rs10793870 9 134342938 [T/C] NM_013318 PRRC2B Silent rs10793871 9 134345401 [A/G] NM_013318 PRRC2B Silent rs11243403 9 134351343 [T/C] NM_013318 PRRC2B EXON Missense_A1276V rs4076428 9 134353724 [T/C] NM_013318 PRRC2B Silent rs7854462 9 134355421 [T/C] NM_013318 PRRC2B Silent rs10901062 9 134361627 [A/G] NM_013318 PRRC2B Silent rs3802349 9 134362878 [T/C] NM_013318 PRRC2B Silent rs10751482 9 134372232 [T/C] NM_013318 PRRC2B EXON Silent rs3802351 9 134373001 [T/G] NM_013318 PRRC2B EXON Silent rs3739501 9 134374274 [T/C] NM_013318 PRRC2B EXON Silent rs3887873 9 134385435 [T/C] NR_148394,NM_001353199,NM_001353200,NM_001353193,NM_001353194,NR_148397,NR_148396,NR_148395,NR_148398,NR_148393,NR_148392,NR_148391,NM_001077366,NM_001077365,NM_001136113,NR_148399,NM_001353198,NM_001136114,NR_148400,NM_001353197,NM_007171,NM_001353195,NM_001353196 POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1 EXON Silent,Nonsense_Q134X,Silent,Nonsense_Q251X,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Nonsense_Q197X,Silent,Silent,Nonsense_Q197X,Nonsense_Q251X,Silent,Silent rs2296949 9 134385436 [A/G] NR_148394,NM_001353199,NM_001353200,NM_001353193,NM_001353194,NR_148397,NR_148396,NR_148395,NR_148398,NR_148393,NR_148392,NR_148391,NM_001077366,NM_001077365,NM_001136113,NR_148399,NM_001353198,NM_001136114,NR_148400,NM_001353197,NM_007171,NM_001353195,NM_001353196 POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1 EXON Silent,Missense_Q134R,Silent,Missense_Q251R,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Missense_Q197R,Silent,Silent,Missense_Q197R,Missense_Q251R,Silent,Silent rs4740164 9 134386781 [A/G] NR_148394,NM_001353199,NM_001353200,NM_001353193,NM_001353194,NR_148397,NR_148396,NR_148395,NR_148398,NR_148393,NR_148392,NR_148391,NM_001077366,NM_001077365,NM_001136113,NR_148399,NM_001353198,NM_001136114,NR_148400,NM_001353197,NM_007171,NM_001353195,NM_001353196 POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1 EXON Silent,Missense_V210I,Missense_V153I,Missense_V327I,Missense_V251I,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Missense_V251I,Missense_V305I,Missense_V305I,Silent,Missense_V273I,Missense_V188I,Silent,Missense_V273I,Missense_V327I,Missense_V188I,Missense_V275I rs3739494 9 134387488 [T/C] NR_148394,NM_001353199,NM_001353200,NM_001353193,NM_001353194,NR_148397,NR_148396,NR_148395,NR_148398,NR_148393,NR_148392,NR_148391,NM_001077366,NM_001077365,NM_001136113,NR_148399,NM_001353198,NM_001136114,NR_148400,NM_001353197,NM_007171,NM_001353195,NM_001353196 POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1 EXON Silent,Synonymous_D254D,Synonymous_D197D,Synonymous_D371D,Synonymous_D295D,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Synonymous_D295D,Synonymous_D349D,Synonymous_D349D,Silent,Synonymous_D317D,Synonymous_D232D,Silent,Synonymous_D317D,Synonymous_D371D,Synonymous_D232D,Synonymous_D319D rs11243406 9 134390870 [A/C] NR_148394,NM_001353199,NM_001353200,NM_001353193,NM_001353194,NR_148397,NR_148396,NR_148395,NR_148398,NR_148393,NR_148392,NR_148391,NM_001077366,NM_001077365,NM_001136113,NR_148399,NM_001353198,NM_001136114,NR_148400,NM_001353197,NM_007171,NM_001353195,NM_001353196 POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1 EXON Silent,Missense_D316E,Missense_D259E,Missense_D433E,Missense_D357E,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Missense_D357E,Missense_D411E,Missense_D411E,Silent,Missense_D379E,Missense_D294E,Silent,Missense_D379E,Missense_D433E,Missense_D294E,Missense_D381E rs4740165 9 134397624 [T/C] NR_148394,NM_001353199,NM_001353200,NM_001353193,NM_001353194,NR_148397,NR_148396,NR_148395,NR_148398,NR_148393,NR_148392,NR_148391,NM_001077366,NM_001077365,NM_001136113,NR_148399,NM_001353198,NM_001136114,NR_148400,NM_001353197,NM_007171,NM_001353195,NM_001353196 POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3739495 9 134398534 [T/C] NR_148394,NM_001353199,NM_001353200,NM_001353193,NM_001353194,NR_148397,NR_148396,NR_148395,NR_148398,NR_148393,NR_148392,NR_148391,NM_001077366,NM_001077365,NM_001136113,NR_148399,NM_001353198,NM_001136114,NR_148400,NM_001353197,NM_007171,NM_001353195,NM_001353196 POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3824395 9 134398719 [T/C] NR_148394,NM_001353199,NM_001353200,NM_001353193,NM_001353194,NR_148397,NR_148396,NR_148395,NR_148398,NR_148393,NR_148392,NR_148391,NM_001077366,NM_001077365,NM_001136113,NR_148399,NM_001353198,NM_001136114,NR_148400,NM_001353197,NM_007171,NM_001353195,NM_001353196 POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10793885 9 134398771 [T/C] NR_148394,NM_001353199,NM_001353200,NM_001353193,NM_001353194,NR_148397,NR_148396,NR_148395,NR_148398,NR_148393,NR_148392,NR_148391,NM_001077366,NM_001077365,NM_001136113,NR_148399,NM_001353198,NM_001136114,NR_148400,NM_001353197,NM_007171,NM_001353195,NM_001353196 POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7857419 9 134398841 [T/C] NR_148394,NM_001353199,NM_001353200,NM_001353193,NM_001353194,NR_148397,NR_148396,NR_148395,NR_148398,NR_148393,NR_148392,NR_148391,NM_001077366,NM_001077365,NM_001136113,NR_148399,NM_001353198,NM_001136114,NR_148400,NM_001353197,NM_007171,NM_001353195,NM_001353196 POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1,POMT1 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2296957 9 134401335 [T/C] NM_001261451,NM_001135954,NM_001261450,NM_031432,NR_134666,NM_001318519,NR_134667 UCK1,UCK1,UCK1,UCK1,UCK1,UCK1,UCK1 EXON Synonymous_P216P,Missense_A180T,Synonymous_P202P,Synonymous_P211P,Silent,Synonymous_P188P,Silent rs6597502 9 134402338 [T/C] NM_001261451,NM_001135954,NM_001261450,NM_031432,NR_134666,NM_001318519,NR_134667 UCK1,UCK1,UCK1,UCK1,UCK1,UCK1,UCK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2282010 9 134405598 [T/C] NM_001261451,NM_001135954,NM_001261450,NM_031432,NR_134666,NM_001318519,NR_134667 UCK1,UCK1,UCK1,UCK1,UCK1,UCK1,UCK1 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3808830 9 134408434 [T/C] rs7874376 9 134411018 [T/C] rs4740263 9 134413298 [T/C] rs4740268 9 134420585 [A/G] rs10117759 9 134428539 [T/C] rs7036006 9 134430764 [T/C] rs11243426 9 134434362 [T/C] rs7040470 9 134434383 [A/G] rs4740170 9 134436280 [T/C] rs4740280 9 134437086 [A/G] rs4740282 9 134440917 [T/C] rs12002074 9 134442561 [A/G] rs12378905 9 134443228 [T/C] rs6597513 9 134445326 [T/G] rs4740283 9 134448296 [A/G] rs17538157 9 134449275 [T/C] rs11243436 9 134449467 [T/C] rs7030401 9 134451843 [A/G] rs943851 9 134452681 [A/G] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 EXON Silent,Silent,Silent rs3739497 9 134453976 [A/G] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 EXON Silent,Silent,Silent rs3765545 9 134458109 [A/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs3765542 9 134458378 [T/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs744313 9 134460326 [A/G] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs753157 9 134461043 [A/G] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs2296952 9 134467314 [A/G] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs3780263 9 134470351 [T/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs3808803 9 134471153 [T/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs2296950 9 134473517 [T/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs11243446 9 134473655 [T/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 EXON Synonymous_E679E,Synonymous_E662E,Synonymous_E680E rs1410562 9 134483805 [A/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs1887787 9 134489763 [A/G] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs2282006 9 134492235 [T/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs10901075 9 134495007 [T/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs10121026 9 134497703 [T/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs2031878 9 134499896 [A/G] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs2026006 9 134501124 [A/G] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs17148121 9 134503810 [T/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs7036709 9 134508442 [T/G] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs11243460 9 134511969 [T/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs11999618 9 134515782 [T/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs1887786 9 134530248 [T/G] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs17148166 9 134536621 [T/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs7048443 9 134536947 [A/G] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs6597517 9 134540980 [A/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs12001816 9 134555186 [T/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs17148186 9 134555407 [A/G] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs11243479 9 134582408 [A/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 Silent,Silent,Silent rs11243480 9 134585181 [T/C] NM_001304275,NM_005312,NM_198679 RAPGEF1,RAPGEF1,RAPGEF1 EXON Silent,Silent,Silent rs1952422 9 134591644 [T/G] NM_001304275,NM_005312 RAPGEF1,RAPGEF1 Silent,Silent rs7020704 9 134593583 [A/C] NM_001304275,NM_005312 RAPGEF1,RAPGEF1 Silent,Silent rs11791414 9 134596993 [T/C] NM_001304275,NM_005312 RAPGEF1,RAPGEF1 Silent,Silent rs4740304 9 134600009 [A/G] NM_001304275,NM_005312 RAPGEF1,RAPGEF1 Silent,Silent rs11243490 9 134604548 [A/C] NM_001304275,NM_005312 RAPGEF1,RAPGEF1 Silent,Silent rs6597525 9 134609779 [A/G] NM_001304275,NM_005312 RAPGEF1,RAPGEF1 Silent,Silent rs11243494 9 134611544 [A/G] NM_001304275,NM_005312 RAPGEF1,RAPGEF1 Silent,Silent rs4740309 9 134621332 [T/G] rs1123551 9 134621809 [T/G] rs2987406 9 134630976 [T/G] rs3012771 9 134631095 [A/G] rs12345826 9 134633665 [T/C] rs12340210 9 134633824 [T/C] rs2987409 9 134634208 [A/G] rs2987410 9 134634566 [A/C] rs10901086 9 134635034 [T/C] rs1887778 9 134635088 [A/G] rs869382 9 134642577 [A/G] rs10901089 9 134643466 [A/G] rs2031872 9 134645218 [T/C] rs3012723 9 134645623 [T/C] rs2987423 9 134647656 [A/G] rs10751488 9 134649676 [A/G] rs3012735 9 134651561 [A/G] rs3012738 9 134652749 [A/G] rs3012740 9 134655176 [A/G] rs2987430 9 134656555 [T/G] rs10793897 9 134657367 [T/C] rs3012748 9 134660273 [A/C] rs3012750 9 134663526 [T/G] rs4740313 9 134663576 [T/C] rs10901096 9 134667753 [T/C] rs10125655 9 134674287 [T/C] rs11243536 9 134675670 [A/G] rs10901101 9 134676400 [T/C] rs12683140 9 134676845 [T/G] rs4740186 9 134677332 [A/G] rs2987364 9 134678778 [A/G] rs3012755 9 134680532 [T/C] rs3012757 9 134682384 [T/C] rs2987367 9 134683985 [A/G] rs11243539 9 134686240 [A/G] rs3012761 9 134687735 [T/C] rs2987369 9 134688582 [T/C] rs10901103 9 134693169 [A/G] rs2031874 9 134696200 [T/G] rs4740188 9 134698342 [T/C] rs943837 9 134708706 [T/C] rs2987389 9 134710059 [T/C] rs2987392 9 134711461 [T/C] rs7850959 9 134715999 [A/C] rs913506 9 134717658 [T/C] rs2987401 9 134719002 [T/C] rs10122844 9 134721070 [A/G] rs11243551 9 134722109 [T/C] rs1547209 9 134722733 [T/C] rs3012780 9 134723854 [T/C] rs3012782 9 134724256 [A/G] rs7350156 9 134725562 [A/G] rs4740321 9 134732553 [A/G] rs7036013 9 134734108 [A/G] rs7848165 9 134755291 [A/G] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs4579577 9 134767080 [A/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs3924215 9 134772966 [T/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs9411321 9 134781550 [T/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs9411419 9 134788993 [T/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs10901112 9 134789096 [A/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs7851852 9 134789845 [A/G] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs6597536 9 134791779 [T/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs7047055 9 134799366 [T/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs4579576 9 134813428 [A/G] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs4128957 9 134818418 [A/G] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs4128956 9 134818509 [T/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs11243574 9 134824764 [A/G] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs10121309 9 134829149 [T/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs7032759 9 134836197 [T/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs11243585 9 134844839 [A/G] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs9411330 9 134861887 [T/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs7040609 9 134865803 [T/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs7043386 9 134866354 [A/G] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs4422886 9 134873927 [T/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs7025089 9 134881443 [A/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs4363310 9 134890430 [T/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs11243598 9 134899743 [A/G] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs7467576 9 134912614 [T/C] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs10512416 9 134913378 [A/G] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs4526483 9 134934986 [T/G] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs7851262 9 134944428 [T/G] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs7041047 9 134948706 [A/G] NM_001253881,NM_004269 MED27,MED27 Silent,Silent rs10117245 9 134959557 [A/C] rs4962112 9 134961834 [T/C] rs12347007 9 134965399 [T/C] rs7038996 9 134965643 [T/C] rs7022935 9 134974333 [A/G] rs9411345 9 134987645 [A/C] rs1331630 9 134993563 [T/C] rs7865653 9 134995268 [T/C] rs1571832 9 134997981 [A/G] rs10901126 9 134999084 [T/C] rs11243634 9 135001703 [T/C] rs1018691 9 135003565 [T/C] rs7866680 9 135003994 [T/C] rs7858174 9 135009024 [T/C] rs9411446 9 135015927 [A/G] rs12684726 9 135018146 [T/G] rs10901130 9 135020849 [A/G] rs11243638 9 135021608 [T/C] rs7046350 9 135025070 [T/G] rs7862560 9 135030039 [T/C] rs1412076 9 135032890 [A/G] rs11243648 9 135034618 [T/G] rs1105685 9 135039556 [T/C] NM_032536 NTNG2 Silent rs6597547 9 135048889 [T/C] NM_032536 NTNG2 Silent rs11788925 9 135048978 [T/C] NM_032536 NTNG2 Silent rs7039329 9 135053756 [T/C] NM_032536 NTNG2 Silent rs11243657 9 135064788 [T/C] NM_032536 NTNG2 Silent rs7870760 9 135070104 [A/G] NM_032536 NTNG2 Silent rs1041504 9 135072009 [A/G] NM_032536 NTNG2 Silent rs3824574 9 135073877 [T/C] NM_032536 NTNG2 EXON Synonymous_F246F rs3739930 9 135073967 [T/C] NM_032536 NTNG2 EXON Synonymous_Y276Y rs871462 9 135077296 [A/G] NM_032536 NTNG2 Silent rs871461 9 135077361 [A/C] NM_032536 NTNG2 Silent rs7865565 9 135081514 [A/G] NM_032536 NTNG2 Silent rs7026497 9 135082979 [A/G] NM_032536 NTNG2 Silent rs7025107 9 135087892 [A/G] NM_032536 NTNG2 Silent rs7018926 9 135089172 [A/C] NM_032536 NTNG2 Silent rs2149171 9 135102254 [T/C] NM_032536 NTNG2 EXON Synonymous_H292H rs4962058 9 135102808 [A/C] NM_032536 NTNG2 Silent rs914420 9 135104786 [T/C] NM_032536 NTNG2 Silent rs914419 9 135105059 [A/G] NM_032536 NTNG2 Silent rs4962173 9 135105964 [A/G] NM_032536 NTNG2 EXON Missense_T346A rs2854926 9 135108510 [A/G] NM_032536 NTNG2 Silent rs2854925 9 135108551 [A/C] NM_032536 NTNG2 Silent rs17148812 9 135109833 [A/G] NM_032536 NTNG2 Silent rs10901140 9 135110034 [A/G] NM_032536 NTNG2 Silent rs1810887 9 135110456 [T/C] NM_032536 NTNG2 Silent rs10901141 9 135110611 [A/G] NM_032536 NTNG2 Silent rs12003603 9 135112999 [A/G] NM_032536 NTNG2 Silent rs914418 9 135120155 [T/C] rs4962060 9 135126458 [T/C] rs4962061 9 135132081 [T/C] rs4962062 9 135132930 [A/G] rs7031969 9 135133039 [A/C] rs1571336 9 135136162 [A/G] rs7875801 9 135138261 [A/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX EXON Silent,Silent,Silent rs11787894 9 135139064 [T/G] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX EXON Silent,Silent,Silent rs3739927 9 135139826 [T/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX EXON Missense_S2641G,Missense_S2612G,Missense_S2612G rs1056899 9 135139901 [T/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX EXON Missense_I2616V,Missense_I2587V,Missense_I2587V rs17148869 9 135150461 [A/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs2296867 9 135150907 [T/G] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs17148873 9 135152439 [A/G] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs11243707 9 135159200 [A/G] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs2274563 9 135164107 [A/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs744133 9 135185355 [A/G] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs10793918 9 135188935 [T/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs3758350 9 135191473 [T/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs12343347 9 135192063 [T/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs17148925 9 135193946 [T/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs10901164 9 135200861 [T/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs543573 9 135202829 [T/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX EXON Missense_I1386V,Missense_I1386V,Missense_I1386V rs11243731 9 135202993 [A/G] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX EXON Missense_P1331L,Missense_P1331L,Missense_P1331L rs1183768 9 135203231 [T/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX EXON Missense_G1252R,Missense_G1252R,Missense_G1252R rs1185193 9 135203409 [A/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX EXON Missense_D1192E,Missense_D1192E,Missense_D1192E rs3739921 9 135203838 [A/G] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX EXON Synonymous_H1049H,Synonymous_H1049H,Synonymous_H1049H rs9411449 9 135206460 [A/G] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX EXON Synonymous_Y359Y,Synonymous_Y359Y,Synonymous_Y359Y rs501377 9 135216186 [A/G] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs514279 9 135218343 [A/G] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs508322 9 135226280 [T/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs488568 9 135227241 [T/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs492082 9 135227581 [T/C] NM_001351528,NM_001351527,NM_015046 SETX,SETX,SETX Silent,Silent,Silent rs544674 9 135230834 [A/G] rs477012 9 135234019 [A/G] rs10217641 9 135235457 [A/C] rs484932 9 135241588 [A/C] rs1185995 9 135245867 [A/G] rs7030233 9 135250473 [A/G] rs17149015 9 135251616 [A/G] NR_134525,NM_001205296,NM_007344 TTF1,TTF1,TTF1 Silent,Silent,Silent rs11243755 9 135257703 [T/C] NR_134525,NM_001205296,NM_007344 TTF1,TTF1,TTF1 Silent,Silent,Silent rs1166299 9 135259513 [T/C] NR_134525,NM_001205296,NM_007344 TTF1,TTF1,TTF1 Silent,Silent,Silent rs554479 9 135264974 [A/G] NR_134525,NM_001205296,NM_007344 TTF1,TTF1,TTF1 Silent,Silent,Silent rs554118 9 135271536 [T/C] NR_134525,NM_001205296,NM_007344 TTF1,TTF1,TTF1 Silent,Silent,Silent rs1166319 9 135271692 [T/C] NR_134525,NM_001205296,NM_007344 TTF1,TTF1,TTF1 Silent,Silent,Silent rs3739916 9 135277007 [T/C] NR_134525,NM_001205296,NM_007344 TTF1,TTF1,TTF1 EXON Silent,Silent,Missense_R401Q rs3739915 9 135277130 [A/C] NR_134525,NM_001205296,NM_007344 TTF1,TTF1,TTF1 EXON Silent,Silent,Missense_G360V rs10901173 9 135285010 [A/G] rs11795094 9 135286130 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs2885495 9 135288807 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs10125557 9 135289797 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs10156646 9 135292355 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs7037570 9 135296341 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs944614 9 135297764 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs944616 9 135298061 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs11795012 9 135298195 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs2362365 9 135298232 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs1412272 9 135298917 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs1001606 9 135300917 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs999483 9 135301389 [T/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs557495 9 135302624 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs4551482 9 135308773 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs563521 9 135310415 [A/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs507371 9 135322596 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs10429632 9 135326806 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs558356 9 135329771 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs562007 9 135330157 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs529317 9 135331958 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs787887 9 135336094 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs541142 9 135338596 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs498495 9 135338786 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs540407 9 135343839 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs569434 9 135344407 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs472207 9 135350866 [A/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs482275 9 135351031 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs565325 9 135351678 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs530582 9 135365028 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs10122574 9 135365135 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs559127 9 135365590 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs12002251 9 135371169 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs561974 9 135372489 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs10120389 9 135372852 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs528460 9 135373497 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs557874 9 135374445 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs7047726 9 135374764 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 EXON Missense_G137R,Missense_G101R rs562350 9 135374898 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 EXON Synonymous_N181N,Synonymous_N145N rs507144 9 135376292 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs4962067 9 135377218 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs515721 9 135377764 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs10901179 9 135378948 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs787904 9 135379520 [A/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs475027 9 135381734 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs7021144 9 135382198 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs17149204 9 135384783 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs518457 9 135386515 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs4962183 9 135387021 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs12005531 9 135389030 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs12115718 9 135391215 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs10793935 9 135391963 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs11243810 9 135392442 [A/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs2363020 9 135394526 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs10118485 9 135406399 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs11243819 9 135406613 [T/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs944812 9 135408571 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs7023572 9 135414981 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs870596 9 135424607 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs11243826 9 135435742 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs17149282 9 135435808 [T/C] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs10122218 9 135442556 [A/G] NM_207417,NM_001282957 CFAP77,CFAP77 Silent,Silent rs433311 9 135448320 [A/C] NM_207417,NM_001282957 CFAP77,CFAP77 EXON Silent,Silent rs811504 9 135450156 [A/G] rs17149310 9 135450636 [A/G] rs717770 9 135453439 [A/G] rs880182 9 135462633 [A/G] NM_020064 BARHL1 Silent rs1328403 9 135467359 [T/C] rs306550 9 135469799 [A/G] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 EXON Silent,Silent,Silent,Silent,Silent,Silent rs306548 9 135470281 [T/C] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 EXON Missense_R843Q,Missense_R714Q,Missense_R770Q,Silent,Missense_R666Q,Missense_R747Q rs306547 9 135470414 [T/C] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 EXON Missense_I799V,Missense_I670V,Missense_I726V,Silent,Missense_I622V,Missense_I703V rs306542 9 135473647 [A/C] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent rs7037273 9 135479687 [A/G] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent rs445990 9 135483721 [T/G] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent rs10901193 9 135483846 [A/G] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent rs10901194 9 135484385 [A/C] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent rs376235 9 135484502 [A/G] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent rs509762 9 135489660 [T/C] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent rs10736856 9 135490787 [T/C] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent rs1028892 9 135493386 [T/C] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent rs306568 9 135494669 [T/C] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent rs36103714 9 135513737 [A/G] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341,NM_138620 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs306537 9 135521303 [T/C] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341,NM_138620 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 EXON Synonymous_L558L,Synonymous_L429L,Synonymous_L558L,Silent,Synonymous_L381L,Synonymous_L462L,Synonymous_L558L rs3739905 9 135521679 [T/C] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341,NM_138620 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs306538 9 135521917 [T/C] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341,NM_138620 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11243866 9 135533833 [T/C] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341,NM_138620,NM_001322344 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17149428 9 135534261 [T/G] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341,NM_138620,NM_001322344 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11243869 9 135535929 [T/G] NM_022779,NM_001322343,NM_001322340,NR_136309,NM_001322342,NM_001322341,NM_138620,NM_001322344 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs408640 9 135544572 [T/G] NM_022779,NM_001322340,NR_136309,NM_001322341,NM_138620,NM_001322344 DDX31,DDX31,DDX31,DDX31,DDX31,DDX31 Silent,Silent,Silent,Silent,Silent,Silent rs10491904 9 135550773 [A/G] NR_133925,NM_012204 GTF3C4,GTF3C4 Silent,Silent rs424416 9 135555341 [A/G] NR_133925,NM_012204 GTF3C4,GTF3C4 Silent,Silent rs3780813 9 135561944 [T/C] NR_133925,NM_012204 GTF3C4,GTF3C4 Silent,Silent rs456396 9 135562800 [A/G] NR_133925,NM_012204 GTF3C4,GTF3C4 Silent,Silent rs302917 9 135568632 [A/C] NR_133925,NM_012204 GTF3C4,GTF3C4 EXON Silent,Silent rs302925 9 135573396 [T/G] rs11243880 9 135579101 [A/C] rs2772002 9 135587540 [T/C] rs7466085 9 135588382 [A/G] rs2772000 9 135590998 [A/C] rs12683728 9 135592024 [T/G] rs306530 9 135598603 [T/C] rs306525 9 135600320 [T/C] rs10901205 9 135602456 [A/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs1999121 9 135602727 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs10901206 9 135603540 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs12550888 9 135605439 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs693692 9 135605490 [T/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs377442 9 135605954 [A/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs531131 9 135606101 [A/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs386472 9 135608113 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs574544 9 135615309 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs4962210 9 135616246 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs913705 9 135616700 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs10901207 9 135618325 [A/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs11243900 9 135624197 [A/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs10901209 9 135626396 [A/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs954390 9 135632056 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs1887964 9 135632480 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs4962078 9 135635852 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs10901212 9 135647021 [A/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs932887 9 135648905 [A/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs4962214 9 135651456 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs2809247 9 135654476 [A/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs1410969 9 135669228 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs215189 9 135671064 [A/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs215187 9 135672580 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs10901214 9 135675674 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs369511 9 135682019 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs2809253 9 135692783 [T/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs2809255 9 135701424 [A/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs2771986 9 135708016 [A/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs4962220 9 135713036 [A/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs17149822 9 135719758 [A/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs2771997 9 135722652 [A/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs2771994 9 135724901 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs17407084 9 135730257 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 EXON Silent,Silent,Missense_D130G rs10491535 9 135737088 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs10901217 9 135740858 [A/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs2526009 9 135742518 [T/C] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 Silent,Silent,Silent rs2231400 9 135753629 [A/G] NM_001317959,NM_001317958,NM_152572 AK8,AK8,AK8 EXON Silent,Silent,Missense_I5T rs2231403 9 135754010 [T/C] NM_001317959,NM_001317958,NM_152572,NR_133631,NM_001316898 AK8,AK8,AK8,SPACA9,SPACA9 EXON Silent,Silent,Silent,Silent,Silent rs2073869 9 135763816 [T/C] NR_133631,NM_001316898,NM_018956,NM_001316897,NM_001316900 SPACA9,SPACA9,SPACA9,SPACA9,SPACA9 EXON Silent,Synonymous_L163L,Synonymous_L163L,Synonymous_L163L,Silent rs1062218 9 135764081 [A/G] NR_133631,NM_001316898,NM_018956,NM_001316897,NM_001316900 SPACA9,SPACA9,SPACA9,SPACA9,SPACA9 EXON Silent,Silent,Silent,Silent,Silent rs2231410 9 135765261 [T/C] NR_133631,NM_001316898,NM_018956,NM_001316897,NM_001316900 SPACA9,SPACA9,SPACA9,SPACA9,SPACA9 EXON Silent,Silent,Silent,Silent,Silent rs11553763 9 135767185 [T/C] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 EXON Silent,Silent,Silent,Silent rs1050700 9 135767943 [T/C] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 EXON Silent,Silent,Silent,Silent rs10491534 9 135769688 [T/C] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 EXON Silent,Silent,Silent,Silent rs739441 9 135770115 [T/C] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 EXON Silent,Silent,Silent,Silent rs739442 9 135770134 [A/G] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 EXON Silent,Silent,Silent,Silent rs2809243 9 135770300 [A/G] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 EXON Silent,Silent,Silent,Silent rs2809244 9 135770347 [A/C] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 EXON Silent,Silent,Silent,Silent rs4962081 9 135772717 [A/G] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 EXON Synonymous_A892A,Synonymous_A822A,Synonymous_A943A,Synonymous_A942A rs2250057 9 135775203 [A/C] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 Silent,Silent,Silent,Silent rs10901219 9 135778827 [T/C] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 Silent,Silent,Silent,Silent rs6597586 9 135786112 [T/C] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 Silent,Silent,Silent,Silent rs1073123 9 135786904 [A/G] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 EXON Missense_M271T,Missense_M201T,Missense_M322T,Missense_M322T rs13295430 9 135799776 [A/G] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 Silent,Silent,Silent,Silent rs3761840 9 135804735 [T/C] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 Silent,Silent,Silent,Silent rs7874234 9 135813001 [T/C] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 Silent,Silent,Silent,Silent rs4419933 9 135815269 [T/C] NM_001162427,NM_001362177,NM_000368,NM_001162426 TSC1,TSC1,TSC1,TSC1 Silent,Silent,Silent,Silent rs4962083 9 135820608 [T/C] rs7040593 9 135826950 [T/C] NM_004188 GFI1B Silent rs3011289 9 135831893 [T/C] NM_004188 GFI1B Silent rs2905082 9 135835334 [T/C] NM_004188 GFI1B Silent rs2905078 9 135840535 [A/G] NM_004188 GFI1B Silent rs11243956 9 135840945 [T/C] NM_004188 GFI1B Silent rs11998995 9 135841420 [T/C] NM_004188 GFI1B Silent rs2905077 9 135841437 [A/G] NM_004188 GFI1B Silent rs2905076 9 135842952 [A/G] NM_004188 GFI1B Silent rs2905072 9 135845035 [A/G] NM_004188 GFI1B Silent rs6597589 9 135849248 [A/G] NM_004188 GFI1B Silent rs7036106 9 135850574 [A/G] NM_004188 GFI1B EXON Silent rs3011260 9 135852953 [A/G] NM_004188 GFI1B Silent rs1964196 9 135855420 [A/G] NM_004188,NM_001135031 GFI1B,GFI1B Silent,Silent rs685783 9 135855768 [T/C] NM_004188,NM_001135031 GFI1B,GFI1B Silent,Silent rs2773818 9 135859519 [A/C] NM_004188,NM_001135031 GFI1B,GFI1B Silent,Silent rs2905069 9 135860839 [A/G] NM_004188,NM_001135031 GFI1B,GFI1B Silent,Silent rs2773822 9 135861033 [T/C] NM_004188,NM_001135031 GFI1B,GFI1B Silent,Silent rs649651 9 135861241 [A/G] NM_004188,NM_001135031 GFI1B,GFI1B Silent,Silent rs2073577 9 135861998 [T/G] NM_004188,NM_001135031 GFI1B,GFI1B Silent,Silent rs606141 9 135862479 [A/G] NM_004188,NM_001135031 GFI1B,GFI1B Silent,Silent rs633153 9 135862632 [T/C] NM_004188,NM_001135031 GFI1B,GFI1B Silent,Silent rs2073819 9 135864190 [A/C] NM_004188,NM_001135031 GFI1B,GFI1B Silent,Silent rs8193003 9 135865496 [T/C] NM_004188,NM_001135031 GFI1B,GFI1B Silent,Silent rs667805 9 135866693 [A/G] NM_004188,NM_001135031 GFI1B,GFI1B EXON Silent,Silent rs678946 9 135867687 [T/C] rs7019702 9 135867989 [A/C] rs507586 9 135872063 [T/C] rs628094 9 135877287 [A/G] rs11243977 9 135877904 [A/C] rs9942933 9 135879020 [A/G] rs603328 9 135881044 [T/C] rs3011267 9 135881193 [A/G] rs3011271 9 135883620 [T/C] rs520812 9 135888407 [A/G] rs3011274 9 135888516 [A/G] rs7021235 9 135889579 [A/G] rs12685748 9 135897389 [T/C] rs2988566 9 135899888 [A/G] rs608604 9 135902962 [A/G] rs7035838 9 135903335 [A/G] rs623489 9 135903997 [T/C] NR_135119 LOC105376306 Silent rs2988571 9 135904566 [A/G] NR_135119 LOC105376306 Silent rs649168 9 135905701 [T/C] NR_135119 LOC105376306 EXON Silent rs675167 9 135913483 [T/C] NM_001122823,NM_001286709,NM_012087 GTF3C5,GTF3C5,GTF3C5 Silent,Silent,Silent rs3789257 9 135920606 [A/G] NM_001122823,NM_001286709,NM_012087 GTF3C5,GTF3C5,GTF3C5 Silent,Silent,Silent rs1541331 9 135926017 [A/G] NM_001122823,NM_001286709,NM_012087 GTF3C5,GTF3C5,GTF3C5 Silent,Silent,Silent rs7863758 9 135929200 [A/C] NM_001122823,NM_001286709,NM_012087 GTF3C5,GTF3C5,GTF3C5 Silent,Silent,Silent rs637435 9 135932235 [A/G] NM_001122823,NM_001286709,NM_012087 GTF3C5,GTF3C5,GTF3C5 EXON Missense_D452N,Missense_D271N,Missense_D445N rs2073821 9 135933122 [T/C] NM_001122823,NM_001286709,NM_012087 GTF3C5,GTF3C5,GTF3C5 Silent,Silent,Silent rs7324 9 135933761 [T/C] NM_001122823,NM_001286709,NM_012087 GTF3C5,GTF3C5,GTF3C5 EXON Silent,Silent,Silent rs586977 9 135934431 [A/G] rs8193023 9 135947165 [T/C] NM_001807 CEL EXON Silent rs2283134 9 135951231 [A/G] rs509064 9 135954310 [A/G] rs563864 9 135955672 [A/G] rs3761829 9 135957091 [A/G] rs694388 9 135957452 [A/G] rs591790 9 135966362 [T/C] rs7023365 9 135972407 [T/C] rs2519090 9 135976679 [A/C] NM_001271775,NM_001271776,NM_001042368,NM_006266,NM_001271774 RALGDS,RALGDS,RALGDS,RALGDS,RALGDS Silent,Silent,Silent,Silent,Silent rs2073822 9 135982088 [A/C] NM_001271775,NM_001271776,NM_001042368,NM_006266,NM_001271774 RALGDS,RALGDS,RALGDS,RALGDS,RALGDS EXON Synonymous_S486S,Synonymous_S475S,Synonymous_S432S,Synonymous_S487S,Synonymous_S458S rs2285375 9 135983504 [T/C] NM_001271775,NM_001271776,NM_001042368,NM_006266,NM_001271774 RALGDS,RALGDS,RALGDS,RALGDS,RALGDS EXON Synonymous_A355A,Synonymous_A344A,Synonymous_A301A,Synonymous_A356A,Synonymous_A327A rs3761824 9 135985796 [T/C] NM_001271775,NM_001271776,NM_001042368,NM_006266,NM_001271774 RALGDS,RALGDS,RALGDS,RALGDS,RALGDS EXON Synonymous_V124V,Synonymous_V125V,Synonymous_V70V,Synonymous_V125V,Synonymous_V108V rs10901235 9 135995166 [A/G] NM_001271775,NM_001271776,NM_001042368,NM_006266,NM_001271774 RALGDS,RALGDS,RALGDS,RALGDS,RALGDS Silent,Silent,Silent,Silent,Silent rs602060 9 136000445 [A/G] NM_001271775,NM_001042368,NM_001271774 RALGDS,RALGDS,RALGDS Silent,Silent,Silent rs671050 9 136001966 [T/C] NM_001271775,NM_001042368,NM_001271774 RALGDS,RALGDS,RALGDS Silent,Silent,Silent rs482670 9 136007358 [A/C] NM_001042368 RALGDS Silent rs626713 9 136007988 [T/C] NM_001042368 RALGDS Silent rs658853 9 136009191 [A/G] NM_001042368 RALGDS Silent rs7022583 9 136023053 [T/C] NM_001042368 RALGDS Silent rs34788999 9 136027423 [A/G] rs34302120 9 136027763 [T/G] rs35875758 9 136028453 [T/C] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 EXON Silent,Silent,Silent,Silent,Silent rs34240512 9 136028457 [T/C] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 EXON Silent,Silent,Silent,Silent,Silent rs34521891 9 136028706 [A/G] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 EXON Silent,Silent,Silent,Silent,Silent rs35184631 9 136029265 [A/G] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 EXON Missense_T231I,Missense_T201I,Missense_T112I,Missense_T248I,Synonymous_L242L rs35366884 9 136029295 [T/G] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 EXON Missense_Q221P,Missense_Q191P,Missense_Q102P,Missense_Q238P,Missense_S232R rs34691037 9 136029312 [A/G] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 EXON Synonymous_Y215Y,Synonymous_Y185Y,Synonymous_Y96Y,Synonymous_Y232Y,Missense_T226M rs34903033 9 136029410 [T/C] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 EXON Missense_D183N,Missense_D153N,Missense_D64N,Missense_D200N,Nonsense_W193X rs35808997 9 136029474 [T/C] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 EXON Synonymous_E161E,Synonymous_E131E,Synonymous_E42E,Synonymous_E178E,Missense_R172K rs34260370 9 136029521 [A/G] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 EXON Missense_R146W,Missense_R116W,Missense_R27W,Missense_R163W,Synonymous_T156T rs35898523 9 136029645 [T/G] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 EXON Nonsense_Y104X,Nonsense_Y74X,Silent,Nonsense_Y121X,Silent rs12350913 9 136030688 [A/G] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 EXON Missense_L62P,Missense_L32P,Silent,Missense_L79P,Missense_L79P rs2073927 9 136031346 [A/G] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 Silent,Silent,Silent,Silent,Silent rs34747295 9 136033076 [A/G] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 Silent,Silent,Silent,Silent,Silent rs2073925 9 136037259 [A/G] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 Silent,Silent,Silent,Silent,Silent rs35578482 9 136037739 [T/C] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 EXON Missense_S21G,Silent,Silent,Missense_S21G,Missense_S21G rs2073924 9 136037742 [A/G] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 EXON Missense_L20F,Silent,Silent,Missense_L20F,Missense_L20F rs35453372 9 136037855 [A/G] NM_001282632,NM_001288572,NM_001288573,NM_021996,NM_001282629 GBGT1,GBGT1,GBGT1,GBGT1,GBGT1 EXON Silent,Silent,Silent,Silent,Silent rs10901239 9 136040134 [A/G] rs7044834 9 136040899 [A/C] rs11244017 9 136042694 [A/G] rs7022409 9 136043270 [T/C] rs4284147 9 136047139 [T/C] rs2039184 9 136047393 [A/G] rs6597604 9 136049780 [A/G] rs10751500 9 136057106 [A/G] rs7028259 9 136061648 [T/C] rs13295207 9 136075679 [A/C] rs10901244 9 136079463 [T/C] rs11244034 9 136080272 [T/C] rs11244035 9 136081319 [T/C] NM_001288987,NR_110242,NR_110243,NM_014581 OBP2B,OBP2B,OBP2B,OBP2B EXON Missense_V167I,Silent,Silent,Missense_V167I rs4489379 9 136084941 [T/C] rs3761821 9 136085783 [T/C] rs7864821 9 136086916 [T/C] rs11999677 9 136096626 [A/G] rs886082 9 136101999 [T/G] rs7852396 9 136108670 [A/G] rs6597612 9 136109910 [A/C] rs13301148 9 136115440 [T/C] rs7036324 9 136116759 [A/G] rs9411367 9 136118513 [T/C] rs9919007 9 136119527 [T/C] rs9411468 9 136119888 [A/G] rs9411471 9 136120091 [A/G] rs7046863 9 136121441 [T/C] rs9411475 9 136127268 [T/C] rs4962113 9 136127641 [T/C] rs7857390 9 136128546 [A/G] rs7466519 9 136131002 [T/C] NM_020469 ABO EXON Silent rs8176749 9 136131188 [T/C] NM_020469 ABO EXON Missense_C310Y rs41302905 9 136131316 [T/C] NM_020469 ABO EXON Synonymous_G267G rs8176746 9 136131322 [T/G] NM_020469 ABO EXON Synonymous_T265T rs8176743 9 136131415 [T/C] NM_020469 ABO EXON Synonymous_P234P rs8176739 9 136131523 [A/G] NM_020469 ABO EXON Synonymous_G198G rs7853989 9 136131592 [G/C] NM_020469 ABO EXON Missense_C175W rs1053878 9 136131651 [A/G] NM_020469 ABO EXON Missense_R156W rs7873522 9 136131905 [T/C] NM_020469 ABO Silent rs8176732 9 136132303 [A/G] NM_020469 ABO Silent rs2073824 9 136132633 [A/G] NM_020469 ABO Silent rs8176722 9 136132754 [A/C] NM_020469 ABO Silent rs8176721 9 136132852 [A/G] NM_020469 ABO EXON Missense_T106M rs8176717 9 136133034 [T/G] NM_020469 ABO Silent rs512770 9 136133506 [A/G] NM_020469 ABO EXON Missense_S74P rs641959 9 136133699 [A/C] NM_020469 ABO Silent rs514708 9 136133743 [T/C] NM_020469 ABO Silent rs549446 9 136135238 [T/C] NM_020469 ABO EXON Missense_H63R rs8176704 9 136135552 [A/G] NM_020469 ABO Silent rs574347 9 136135659 [T/C] NM_020469 ABO Silent rs688976 9 136136770 [A/C] NM_020469 ABO EXON Missense_F36V rs687289 9 136137106 [A/G] NM_020469 ABO Silent rs8176694 9 136137646 [T/C] NM_020469 ABO Silent rs672316 9 136138125 [T/G] NM_020469 ABO Silent rs657152 9 136139265 [A/C] NM_020469 ABO Silent rs8176682 9 136139297 [T/C] NM_020469 ABO Silent rs474279 9 136139617 [T/C] NM_020469 ABO Silent rs507666 9 136149399 [A/G] NM_020469 ABO Silent rs630014 9 136149722 [A/G] NM_020469 ABO Silent rs568203 9 136151445 [A/C] rs8176630 9 136152722 [T/C] rs552148 9 136153481 [T/C] rs579459 9 136154168 [T/C] rs7030248 9 136155359 [A/G] rs633862 9 136155444 [T/C] rs9411381 9 136156067 [T/C] rs558240 9 136157133 [A/G] rs7867739 9 136157924 [T/C] rs1752337 9 136160228 [T/G] rs9411493 9 136161851 [A/G] rs624960 9 136175051 [T/C] rs4962043 9 136177993 [A/G] rs7357661 9 136179407 [A/G] rs11244079 9 136184526 [A/G] rs17150319 9 136184598 [T/C] rs493014 9 136187163 [T/G] rs9411396 9 136187652 [T/G] rs17150482 9 136194595 [T/C] rs12335 9 136197834 [A/G] NM_001278942,NR_103874,NM_006753 SURF6,SURF6,SURF6 EXON Silent,Silent,Silent rs10793964 9 136198589 [G/C] NM_001278942,NR_103874,NM_006753 SURF6,SURF6,SURF6 EXON Silent,Silent,Silent rs886090 9 136199503 [A/G] NM_001278942,NR_103874,NM_006753 SURF6,SURF6,SURF6 EXON Synonymous_C162C,Silent,Missense_R163W rs12001640 9 136200150 [A/G] NM_001278942,NR_103874,NM_006753 SURF6,SURF6,SURF6 Silent,Silent,Silent rs1320434 9 136201228 [T/C] NM_001278942,NR_103874,NM_006753 SURF6,SURF6,SURF6 EXON Missense_D102N,Silent,Missense_D102N rs563666 9 136201470 [A/C] NM_001278942,NR_103874,NM_006753 SURF6,SURF6,SURF6 Silent,Silent,Silent rs11655 9 136207843 [T/C] NM_181491,NM_133640 MED22,MED22 EXON Silent,Silent rs621907 9 136208044 [T/C] NM_181491,NM_133640 MED22,MED22 EXON Silent,Silent rs7870707 9 136209319 [A/C] NM_181491,NM_133640 MED22,MED22 EXON Silent,Silent rs513822 9 136210046 [T/G] NM_181491,NM_133640 MED22,MED22 EXON Silent,Silent rs553877 9 136214955 [A/G] NM_181491,NM_133640 MED22,MED22 EXON Silent,Silent rs28693986 9 136217958 [A/G] NM_000972 RPL7A Silent rs2021976 9 136218889 [A/G] NM_001280787,NM_003172 SURF1,SURF1 Silent,Silent rs28615629 9 136221557 [A/G] NM_001280787,NM_003172 SURF1,SURF1 EXON Silent,Synonymous_L94L rs28436827 9 136222106 [A/G] NM_001280787,NM_003172 SURF1,SURF1 Silent,Silent rs2051680 9 136222789 [A/G] NM_001280787,NM_003172 SURF1,SURF1 Silent,Silent rs2296809 9 136227017 [A/G] NM_017503,NM_001278928 SURF2,SURF2 Silent,Silent rs12763 9 136227260 [A/G] NM_017503,NM_001278928 SURF2,SURF2 EXON Missense_S213G,Missense_S213G rs2240171 9 136228305 [A/G] rs11543366 9 136229950 [T/C] NM_001280791,NM_001280789,NM_033161,NM_001280793,NM_001280788,NM_001280792,NM_001280790 SURF4,SURF4,SURF4,SURF4,SURF4,SURF4,SURF4 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7019129 9 136243665 [T/G] NM_001280788,NM_153710,NR_103997 SURF4,STKLD1,STKLD1 Silent,Silent,Silent rs28602591 9 136246666 [T/C] NM_153710,NR_103997 STKLD1,STKLD1 Silent,Silent rs28711505 9 136248949 [T/G] NM_153710,NR_103997 STKLD1,STKLD1 Silent,Silent rs3118661 9 136251026 [A/G] NM_153710,NR_103997 STKLD1,STKLD1 Silent,Silent rs8181039 9 136253927 [A/G] NM_153710,NR_103997 STKLD1,STKLD1 Silent,Silent rs36091105 9 136259809 [T/C] NM_153710,NR_103997 STKLD1,STKLD1 Silent,Silent rs7040821 9 136263584 [A/C] NM_153710,NR_103997 STKLD1,STKLD1 Silent,Silent rs17150554 9 136269143 [A/G] NM_153710,NR_103997 STKLD1,STKLD1 EXON Missense_R568Q,Silent rs3124782 9 136270996 [T/C] NM_153710,NR_103997 STKLD1,STKLD1 EXON Silent,Silent rs28711662 9 136273902 [T/C] NM_001279350,NM_020385,NR_103996,NR_103995,NM_001279351,NM_001279349 REXO4,REXO4,REXO4,REXO4,REXO4,REXO4 EXON Missense_S218N,Missense_S355N,Silent,Silent,Missense_S262N,Missense_S183N rs3124781 9 136275313 [T/C] NM_001279350,NM_020385,NR_103996,NR_103995,NM_001279351,NM_001279349 REXO4,REXO4,REXO4,REXO4,REXO4,REXO4 Silent,Silent,Silent,Silent,Silent,Silent rs2285487 9 136277482 [T/C] NM_001279350,NM_020385,NR_103996,NR_103995,NM_001279351,NM_001279349 REXO4,REXO4,REXO4,REXO4,REXO4,REXO4 EXON Missense_T146A,Missense_T283A,Silent,Silent,Missense_T190A,Silent rs3124779 9 136281966 [A/G] NM_001279350,NM_020385,NR_103996,NR_103995,NM_001279351,NM_001279349,NR_024514 REXO4,REXO4,REXO4,REXO4,REXO4,REXO4,ADAMTS13 Silent,Silent,Silent,Silent,Silent,Silent,Silent rs28488980 9 136285739 [A/G] NR_024514 ADAMTS13 Silent rs34024143 9 136287582 [T/C] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 EXON Silent,Missense_R7W,Missense_R7W,Missense_R7W rs36218898 9 136290429 [T/C] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs28571612 9 136290672 [A/G] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 EXON Silent,Synonymous_P118P,Synonymous_P118P,Synonymous_P118P rs3118667 9 136291063 [T/C] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 EXON Silent,Synonymous_A140A,Synonymous_A140A,Synonymous_A140A rs34054981 9 136291361 [T/C] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 EXON Silent,Synonymous_G194G,Synonymous_G194G,Synonymous_G194G rs681092 9 136299394 [T/C] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs2301612 9 136301982 [G/C] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 EXON Silent,Missense_Q448E,Missense_Q417E,Missense_Q448E rs2028002 9 136303253 [T/C] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs3124768 9 136304497 [A/G] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 EXON Silent,Synonymous_T572T,Synonymous_T541T,Synonymous_T572T rs2073933 9 136305275 [A/G] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs28647808 9 136305530 [C/G] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 EXON Silent,Missense_P618A,Missense_P587A,Missense_P618A rs36090624 9 136305552 [A/G] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 EXON Silent,Missense_R625H,Missense_R594H,Missense_R625H rs28645493 9 136305738 [C/G] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs651625 9 136305856 [T/C] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs603551 9 136307089 [A/G] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs602184 9 136307408 [A/G] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs592514 9 136309841 [A/T] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs652600 9 136311017 [A/G] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs34063534 9 136311159 [T/C] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs36221592 9 136311172 [T/C] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs4962150 9 136311391 [A/G] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs3094375 9 136319068 [T/C] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs28503257 9 136319589 [A/G] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 EXON Silent,Missense_A1033T,Missense_A1002T,Missense_A1033T rs36222582 9 136320388 [T/C] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs4962153 9 136323754 [A/G] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 Silent,Silent,Silent,Silent rs1055432 9 136324239 [A/C] NR_024514,NM_139027,NM_139026,NM_139025 ADAMTS13,ADAMTS13,ADAMTS13,ADAMTS13 EXON Silent,Synonymous_T1351T,Synonymous_T1320T,Synonymous_T1407T rs1054379 9 136335824 [T/C] NM_017586,NM_001242369,NM_001242370,NM_001135775 CACFD1,CACFD1,CACFD1,CACFD1 EXON Silent,Silent,Silent,Silent rs3094378 9 136337168 [A/G] NM_017585,NM_001145099 SLC2A6,SLC2A6 EXON Missense_T500M,Missense_T438M rs3124760 9 136339959 [T/C] NM_017585,NM_001145099 SLC2A6,SLC2A6 Silent,Silent rs28615428 9 136342768 [A/C] NM_017585,NM_001145099 SLC2A6,SLC2A6 Silent,Silent rs968471 9 136344613 [A/G] rs3124758 9 136344853 [A/G] rs7860364 9 136351927 [A/G] rs28517799 9 136353350 [A/G] rs736417 9 136359085 [A/G] rs4962157 9 136362740 [A/C] rs17810852 9 136365075 [A/G] rs9330459 9 136371224 [T/G] rs35860798 9 136390660 [A/G] rs3763650 9 136395973 [T/C] rs1003664 9 136396252 [T/C] rs17150640 9 136397058 [T/C] rs1008250 9 136397834 [A/G] NM_001145320 ADAMTSL2 Silent rs756770 9 136398858 [A/C] NM_001145320 ADAMTSL2 Silent rs9696672 9 136399075 [A/G] NM_001145320 ADAMTSL2 Silent rs28569945 9 136402067 [T/G] NM_001145320,NM_014694 ADAMTSL2,ADAMTSL2 Silent,Silent rs28734006 9 136406008 [A/C] NM_001145320,NM_014694 ADAMTSL2,ADAMTSL2 EXON Synonymous_G189G,Synonymous_G189G rs28520600 9 136407208 [T/C] NM_001145320,NM_014694 ADAMTSL2,ADAMTSL2 Silent,Silent rs11537116 9 136408841 [T/C] NM_001145320,NM_014694 ADAMTSL2,ADAMTSL2 Silent,Silent rs11516159 9 136408876 [A/G] NM_001145320,NM_014694 ADAMTSL2,ADAMTSL2 Silent,Silent rs9330463 9 136409854 [T/C] NM_001145320,NM_014694 ADAMTSL2,ADAMTSL2 Silent,Silent rs10119879 9 136410525 [A/G] NM_001145320,NM_014694 ADAMTSL2,ADAMTSL2 Silent,Silent rs11507718 9 136411785 [T/C] NM_001145320,NM_014694 ADAMTSL2,ADAMTSL2 Silent,Silent rs2073873 9 136412013 [G/C] NM_001145320,NM_014694 ADAMTSL2,ADAMTSL2 Silent,Silent rs10120207 9 136413041 [A/C] NM_001145320,NM_014694 ADAMTSL2,ADAMTSL2 Silent,Silent rs9696616 9 136414531 [A/G] NM_001145320,NM_014694 ADAMTSL2,ADAMTSL2 Silent,Silent rs11535670 9 136414937 [A/G] NM_001145320,NM_014694 ADAMTSL2,ADAMTSL2 Silent,Silent rs9777051 9 136415608 [A/G] NM_001145320,NM_014694 ADAMTSL2,ADAMTSL2 Silent,Silent rs28647521 9 136428683 [A/G] NM_001145320,NM_014694 ADAMTSL2,ADAMTSL2 Silent,Silent rs28666751 9 136454105 [T/C] rs10993774 9 136454700 [A/G] rs7040825 9 136456607 [T/C] rs7856830 9 136457146 [T/C] rs9409872 9 136458311 [T/G] rs3025299 9 136458404 [T/C] rs3025316 9 136459543 [T/C] rs10821577 9 136460220 [A/G] rs1079783 9 136462863 [A/G] rs3025324 9 136466648 [T/C] rs3025325 9 136466832 [T/C] rs3025336 9 136469322 [T/G] rs7025648 9 136471193 [T/C] rs1029372 9 136478442 [A/G] rs3025351 9 136479571 [A/G] rs3025363 9 136482068 [A/G] rs3025365 9 136482476 [A/G] rs7872903 9 136484292 [T/C] rs916658 9 136487721 [C/G] rs11998869 9 136488144 [A/G] rs10993874 9 136489539 [T/C] rs2519765 9 136494425 [T/C] rs2519148 9 136494566 [A/G] rs3025369 9 136494594 [T/G] rs2519147 9 136495318 [A/G] rs3025373 9 136496708 [A/G] rs1076153 9 136498143 [T/G] rs1076150 9 136498761 [T/C] rs1611114 9 136500203 [T/C] rs1611115 9 136500515 [T/C] rs3025382 9 136502321 [A/G] NM_000787 DBH Silent rs2519143 9 136502328 [A/G] NM_000787 DBH Silent rs3025388 9 136503256 [A/G] NM_000787 DBH Silent rs2007153 9 136503819 [T/C] NM_000787 DBH Silent rs2797851 9 136504580 [A/G] NM_000787 DBH Silent rs1611118 9 136504923 [T/C] NM_000787 DBH Silent rs1108580 9 136505114 [A/G] NM_000787 DBH EXON Synonymous_E162E rs1108581 9 136505241 [A/G] NM_000787 DBH Silent rs2873804 9 136505644 [T/C] NM_000787 DBH Silent rs5320 9 136507473 [A/G] NM_000787 DBH EXON Missense_A211T rs5321 9 136507559 [C/G] NM_000787 DBH EXON Missense_K239N rs5322 9 136507577 [T/C] NM_000787 DBH EXON Synonymous_H245H rs5324 9 136508658 [A/G] NM_000787 DBH EXON Missense_D290N rs1611123 9 136509083 [T/C] NM_000787 DBH Silent rs4531 9 136509370 [T/G] NM_000787 DBH EXON Missense_A318S rs1541332 9 136511516 [A/G] NM_000787 DBH Silent rs2519154 9 136512275 [T/C] NM_000787 DBH Silent rs7876027 9 136514539 [T/G] NM_000787 DBH Silent rs2283123 9 136515297 [T/C] NM_000787 DBH Silent rs2283124 9 136515330 [T/C] NM_000787 DBH Silent rs77905 9 136518097 [A/G] NM_000787 DBH EXON Synonymous_T470T rs2097628 9 136519702 [A/G] NM_000787 DBH Silent rs3025422 9 136522426 [T/C] NM_000787,NR_102735 DBH,DBH-AS1 EXON Silent,Silent rs129882 9 136523669 [T/C] NM_000787 DBH EXON Silent rs13306304 9 136523959 [A/G] NM_000787 DBH EXON Silent rs129885 9 136527226 [A/C] rs129886 9 136528721 [T/C] NM_007101,NM_001134707 SARDH,SARDH EXON Silent,Silent rs2073835 9 136532183 [A/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs2797840 9 136536633 [A/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs129932 9 136536679 [A/G] NM_007101,NM_001134707 SARDH,SARDH EXON Synonymous_I768I,Synonymous_I768I rs129889 9 136542868 [A/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs129956 9 136544943 [T/C] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs129895 9 136545363 [A/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs129940 9 136545423 [A/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs2519072 9 136550817 [A/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs129901 9 136552263 [A/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs4744533 9 136552362 [T/C] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs886016 9 136555629 [T/C] NM_007101,NM_001134707 SARDH,SARDH EXON Missense_M648V,Missense_M648V rs12345624 9 136559164 [A/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs2073817 9 136559460 [T/C] NM_007101,NM_001134707 SARDH,SARDH EXON Missense_R614H,Missense_R614H rs2502740 9 136561367 [A/G] NM_007101,NM_001134707 SARDH,SARDH EXON Synonymous_S595S,Synonymous_S595S rs10993768 9 136563926 [T/C] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs2427995 9 136566959 [A/C] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs2427989 9 136569061 [T/C] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs694821 9 136570740 [T/C] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs2510245 9 136571089 [A/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs4979633 9 136571886 [T/C] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs4979631 9 136572750 [T/C] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs2073815 9 136573412 [A/G] NM_007101,NM_001134707 SARDH,SARDH EXON Synonymous_H489H,Synonymous_H489H rs511293 9 136577094 [A/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs522676 9 136579589 [A/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs2427981 9 136581419 [A/C] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs2027963 9 136584196 [T/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs12341402 9 136584828 [T/C] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs7040170 9 136586367 [A/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs2510234 9 136590369 [T/C] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs2251217 9 136592014 [T/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs2283125 9 136592342 [A/C] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs3824568 9 136597979 [T/C] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs3780804 9 136598128 [T/G] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs573904 9 136599146 [T/C] NM_007101,NM_001134707 SARDH,SARDH EXON Synonymous_Q50Q,Synonymous_Q50Q rs493901 9 136600201 [T/C] NM_007101,NM_001134707 SARDH,SARDH Silent,Silent rs10465165 9 136606230 [T/G] rs2510257 9 136608669 [T/G] rs646708 9 136612426 [A/G] rs491220 9 136617292 [A/G] rs667420 9 136620568 [A/C] rs10993787 9 136622634 [A/G] rs10993790 9 136624542 [T/G] rs642193 9 136626906 [A/C] rs2797825 9 136629298 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs622035 9 136632662 [A/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs9722384 9 136633606 [A/G] NM_001134398,NM_003371 VAV2,VAV2 EXON Synonymous_I849I,Synonymous_I810I rs9409863 9 136643239 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs602990 9 136643994 [T/C] NM_001134398,NM_003371 VAV2,VAV2 EXON Missense_M594V,Missense_M584V rs9409864 9 136647466 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs525060 9 136647624 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs650830 9 136647817 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2488563 9 136648535 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2023665 9 136650740 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2520003 9 136654038 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs3824561 9 136657960 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs10993803 9 136658987 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2428099 9 136661934 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs10821525 9 136662638 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs7865299 9 136662928 [A/G] NM_001134398,NM_003371 VAV2,VAV2 EXON Synonymous_L280L,Synonymous_L275L rs2510262 9 136666483 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs10123394 9 136666560 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2488552 9 136669004 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs7021663 9 136676014 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs739450 9 136678685 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs12337328 9 136681696 [T/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs7026263 9 136682408 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs7026295 9 136682482 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs3858101 9 136686242 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2486335 9 136689278 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs3893493 9 136693906 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2260095 9 136705956 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs739465 9 136712122 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs10993826 9 136719045 [T/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs3819502 9 136721078 [A/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs10993831 9 136722358 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs12344583 9 136723520 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs10821527 9 136733975 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs12341506 9 136740971 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs7869522 9 136747090 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2789853 9 136753246 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2073883 9 136754076 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2519766 9 136755590 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2428082 9 136758586 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2519777 9 136759508 [A/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2810472 9 136760639 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs13287070 9 136760719 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs3780751 9 136762458 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs10993845 9 136762800 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs13291383 9 136762812 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2157834 9 136767301 [A/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2519996 9 136769348 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs10114577 9 136771319 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs679923 9 136771432 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2789825 9 136774217 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs608402 9 136779153 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs608968 9 136785840 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2265520 9 136790282 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs16763 9 136792765 [A/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2519098 9 136798370 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs654387 9 136803161 [T/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2428003 9 136803249 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2073886 9 136804211 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2810531 9 136805443 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2519803 9 136805789 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs520308 9 136807238 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2519799 9 136810857 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs481964 9 136813341 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs648353 9 136822827 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs664026 9 136824023 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2073829 9 136826457 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs10993877 9 136829071 [A/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs452999 9 136832528 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs452943 9 136832577 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs3780792 9 136835343 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2506686 9 136835918 [A/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs618439 9 136836196 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs679106 9 136839840 [A/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs425850 9 136843974 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs435586 9 136844973 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs7018770 9 136848821 [A/G] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs420897 9 136851763 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2789864 9 136852891 [T/C] NM_001134398,NM_003371 VAV2,VAV2 Silent,Silent rs2810475 9 136865247 [T/C] rs460126 9 136865879 [T/G] rs2519826 9 136869110 [T/G] rs419218 9 136870787 [T/G] rs17664384 9 136874066 [T/C] rs464930 9 136874158 [A/G] rs441233 9 136876021 [A/G] rs408307 9 136892523 [T/C] NM_001355256,NR_149319 BRD3OS,BRD3OS EXON Silent,Silent rs3802502 9 136897026 [A/G] NM_007371 BRD3 EXON Silent rs1051467 9 136898236 [A/G] NM_007371 BRD3 EXON Silent rs17151353 9 136898585 [T/C] NM_007371 BRD3 EXON Silent rs443876 9 136898922 [T/G] NM_007371 BRD3 Silent rs3847320 9 136906752 [A/G] NM_007371 BRD3 Silent rs457420 9 136909261 [T/C] NM_007371 BRD3 Silent rs460154 9 136909309 [A/G] NM_007371 BRD3 Silent rs464826 9 136913355 [T/C] NM_007371 BRD3 EXON Synonymous_L312L rs2301576 9 136915508 [T/C] NM_007371 BRD3 EXON Synonymous_P234P rs2073818 9 136918662 [A/C] NM_007371 BRD3 EXON Silent rs17566226 9 136921015 [A/G] NM_007371,NR_135126 BRD3,LOC100130548 Silent,Silent rs2810492 9 136923972 [A/G] NM_007371 BRD3 Silent rs1124317 9 136925451 [A/G] NM_007371 BRD3 Silent rs1076148 9 136927657 [T/C] NM_007371 BRD3 Silent rs1075654 9 136928276 [A/G] NM_007371 BRD3 Silent rs10993907 9 136928644 [T/C] NM_007371 BRD3 Silent rs2078778 9 136938961 [A/G] rs10993924 9 136943067 [T/C] rs2427951 9 136950303 [T/C] rs2506696 9 136950691 [A/C] rs2506694 9 136952817 [A/G] rs2427971 9 136961808 [T/C] rs12344192 9 136965553 [T/C] rs4292757 9 136986911 [A/G] rs10993945 9 136991034 [A/G] rs4358859 9 136992903 [T/C] rs4744560 9 136993590 [T/C] rs28577297 9 136994129 [A/G] rs28672704 9 136998279 [A/G] rs28464304 9 136999786 [A/G] rs35726748 9 137002091 [A/G] NM_017588 WDR5 Silent rs34856382 9 137012032 [T/C] NM_017588,NM_052821 WDR5,WDR5 Silent,Silent rs34775966 9 137015216 [T/G] NM_017588,NM_052821 WDR5,WDR5 Silent,Silent rs28758854 9 137015951 [T/C] NM_017588,NM_052821 WDR5,WDR5 Silent,Silent rs28604373 9 137018130 [A/G] NM_017588,NM_052821 WDR5,WDR5 Silent,Silent rs28694247 9 137019776 [A/G] NM_017588,NM_052821 WDR5,WDR5 Silent,Silent rs28516666 9 137026934 [T/C] rs28498266 9 137031454 [A/G] rs28586903 9 137032165 [T/C] rs28619507 9 137037262 [T/C] rs28379755 9 137037501 [T/C] rs28404378 9 137038257 [A/G] rs28481912 9 137039240 [A/G] rs12376985 9 137092388 [A/G] rs7872110 9 137098042 [T/C] rs11185726 9 137101104 [T/C] rs7874315 9 137102473 [T/C] rs7027150 9 137103126 [T/C] rs7031566 9 137104155 [T/C] rs11791747 9 137106879 [A/G] rs17567190 9 137106964 [T/C] rs7033108 9 137109245 [A/G] rs11185664 9 137110257 [T/C] rs13302475 9 137110907 [A/G] rs11185665 9 137111146 [A/G] rs10881585 9 137112421 [T/C] rs7873963 9 137112655 [T/C] rs7041347 9 137113356 [T/C] rs11185668 9 137113880 [A/G] rs11185670 9 137115785 [A/C] rs4994332 9 137117194 [T/C] rs7028191 9 137117496 [T/C] rs4917357 9 137117770 [A/G] rs7042719 9 137118893 [T/C] rs17093638 9 137119281 [A/G] rs7848481 9 137120661 [T/C] rs7848058 9 137121862 [A/G] rs10881587 9 137122827 [T/G] rs17093644 9 137123248 [T/C] rs7863190 9 137124673 [T/C] rs10785877 9 137125501 [A/G] rs11185681 9 137126551 [A/G] rs1889157 9 137131611 [A/G] rs4917360 9 137137245 [T/C] rs4917362 9 137138000 [T/C] rs10785879 9 137138414 [A/C] rs11185689 9 137142353 [T/C] rs4917339 9 137147081 [T/C] rs10748520 9 137153870 [T/C] rs10785882 9 137153882 [A/G] rs11789899 9 137155945 [A/G] rs7867061 9 137159154 [A/G] rs1889151 9 137160637 [T/G] rs1889152 9 137160810 [A/G] rs7848672 9 137163255 [T/C] rs1930788 9 137163718 [T/C] rs10785883 9 137163978 [T/G] rs12346747 9 137165349 [A/G] rs17093685 9 137165429 [A/C] rs7858041 9 137166136 [T/C] rs7874131 9 137169720 [T/C] rs12350120 9 137170414 [A/G] rs11185709 9 137174079 [A/G] rs875464 9 137174180 [A/G] rs11185717 9 137182099 [A/G] rs7032984 9 137185046 [A/G] rs3750548 9 137186036 [T/C] NR_146518 LINC02247 EXON Silent rs7871088 9 137186524 [T/C] NR_146518 LINC02247 Silent rs12006542 9 137195632 [T/C] rs11794220 9 137196129 [T/C] rs11792663 9 137196155 [A/G] rs12339163 9 137205188 [A/G] rs10881574 9 137205222 [T/C] rs11185644 9 137210863 [T/C] rs11185647 9 137215828 [A/G] rs7855881 9 137220543 [T/G] NM_002957 RXRA Silent rs872298 9 137222137 [A/G] NM_002957 RXRA Silent rs10881576 9 137223240 [T/C] NM_002957 RXRA Silent rs3818740 9 137226094 [T/C] NM_002957 RXRA Silent rs10881578 9 137232535 [A/G] NM_002957 RXRA Silent rs10881580 9 137234671 [A/G] NM_002957 RXRA Silent rs4917354 9 137237661 [T/C] NM_002957 RXRA Silent rs914853 9 137239163 [A/G] NM_002957 RXRA Silent rs11185659 9 137243383 [T/C] NM_002957 RXRA Silent rs12348547 9 137246262 [T/C] NM_002957 RXRA Silent rs7041449 9 137248674 [T/C] NM_002957 RXRA Silent rs7853934 9 137252760 [T/C] NM_002957 RXRA Silent rs7048602 9 137253447 [A/G] NM_002957 RXRA Silent rs10881582 9 137256078 [A/G] NM_002957 RXRA Silent rs11185660 9 137259992 [T/C] NM_002957 RXRA Silent rs7039190 9 137266704 [A/C] NM_002957 RXRA Silent rs34312136 9 137269456 [T/C] NM_002957 RXRA Silent rs35079168 9 137280939 [A/G] NM_002957,NM_001291920 RXRA,RXRA Silent,Silent rs4501664 9 137284923 [A/G] NM_002957,NM_001291920 RXRA,RXRA Silent,Silent rs11102986 9 137285503 [A/G] NM_002957,NM_001291920 RXRA,RXRA Silent,Silent rs11103473 9 137287629 [T/A] NM_002957,NM_001291920 RXRA,RXRA Silent,Silent rs12004589 9 137290725 [T/G] NM_002957,NM_001291920 RXRA,RXRA Silent,Silent rs11103633 9 137290768 [A/G] NM_002957,NM_001291920 RXRA,RXRA Silent,Silent rs6537998 9 137292505 [T/C] NM_002957,NM_001291920 RXRA,RXRA Silent,Silent rs7869783 9 137292773 [A/G] NM_002957,NM_001291920 RXRA,RXRA Silent,Silent rs1805337 9 137293572 [T/C] NM_002957,NM_001291920 RXRA,RXRA EXON Synonymous_I41I,Synonymous_I14I rs875444 9 137295304 [A/G] NM_002957,NM_001291920 RXRA,RXRA Silent,Silent rs12336468 9 137298699 [T/G] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA EXON Silent,Silent,Silent rs1805352 9 137299949 [A/C] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs3132296 9 137302631 [T/C] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs11789076 9 137302939 [T/C] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs3118529 9 137304915 [T/C] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs731516 9 137308300 [A/G] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs3118536 9 137308462 [A/C] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs4240705 9 137311400 [A/G] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs11103462 9 137311572 [A/G] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs6537944 9 137312828 [T/C] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs12349076 9 137315293 [A/G] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs3118571 9 137318178 [T/C] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs1536475 9 137321156 [A/G] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs3132294 9 137324120 [T/C] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs35315770 9 137324375 [A/G] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs877954 9 137326408 [A/G] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs1805343 9 137328286 [A/G] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA Silent,Silent,Silent rs1805348 9 137328442 [A/G] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA EXON Synonymous_A457A,Synonymous_A430A,Synonymous_A360A rs1805342 9 137328700 [T/C] NM_002957,NM_001291920,NM_001291921 RXRA,RXRA,RXRA EXON Silent,Silent,Silent rs3118526 9 137337357 [T/C] rs9409929 9 137340513 [A/G] rs11103603 9 137341600 [T/C] rs3118545 9 137348592 [T/G] rs3118546 9 137351129 [T/C] rs7033624 9 137352272 [A/G] rs7870490 9 137358801 [T/C] rs10776936 9 137359635 [A/G] rs11103714 9 137359948 [A/G] rs4842229 9 137360936 [A/G] rs943430 9 137366540 [A/G] rs7033773 9 137369200 [A/C] rs3818518 9 137374584 [A/G] rs1555949 9 137377445 [A/G] rs7871031 9 137379635 [A/G] rs13295631 9 137380516 [T/C] rs10776949 9 137382629 [A/C] rs12336911 9 137384140 [T/C] rs943434 9 137385159 [A/G] rs7863795 9 137392705 [T/G] rs7858838 9 137397609 [A/G] rs9409898 9 137406529 [T/C] rs9409899 9 137406638 [A/G] rs9409970 9 137406713 [T/C] rs943427 9 137408432 [T/G] rs3132330 9 137408717 [A/G] rs3132329 9 137413400 [T/C] rs4842031 9 137415319 [T/C] rs3118580 9 137415342 [T/C] rs7037930 9 137417305 [A/G] rs10776839 9 137417308 [T/G] rs3118586 9 137420521 [A/G] rs3118589 9 137422484 [A/G] rs4841898 9 137424233 [T/C] rs3132321 9 137425441 [T/C] rs3132317 9 137426119 [T/C] rs3118593 9 137426334 [A/C] rs1006418 9 137426935 [A/G] rs3132315 9 137427442 [T/C] rs3118595 9 137427767 [A/G] rs1409832 9 137428425 [T/G] rs4240698 9 137429719 [T/C] rs3132310 9 137431373 [T/C] rs1316404 9 137431424 [A/G] rs9409912 9 137434547 [T/G] rs3118515 9 137436314 [A/G] rs943423 9 137437183 [A/G] rs3118520 9 137441595 [A/G] rs3132304 9 137443896 [A/G] rs11103276 9 137447293 [A/G] rs7025493 9 137469004 [A/G] rs7855550 9 137470639 [T/C] rs11103404 9 137476593 [A/G] rs11103407 9 137477402 [A/G] rs10858254 9 137485476 [A/G] rs7862997 9 137485876 [T/C] rs4842136 9 137489483 [A/G] rs12348251 9 137490048 [T/G] rs11103417 9 137494787 [A/G] rs7020813 9 137494819 [T/C] rs7847993 9 137496881 [T/C] rs7856818 9 137503695 [T/C] rs12340702 9 137506340 [A/C] rs11103429 9 137506578 [A/G] rs11103433 9 137510144 [A/G] rs6537934 9 137511278 [T/C] rs12344933 9 137512483 [A/G] rs7027374 9 137514962 [A/G] rs4424343 9 137515158 [A/G] rs4841920 9 137516213 [A/C] rs7341858 9 137516625 [T/C] rs4076173 9 137517022 [A/G] rs7865626 9 137518733 [A/C] rs4304399 9 137520936 [T/C] rs7021140 9 137530346 [A/G] rs12002283 9 137533436 [T/C] rs11103455 9 137538057 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs10858265 9 137543874 [T/C] NM_001278074,NM_000093,NR_138049 COL5A1,COL5A1,COL5A1-AS1 Silent,Silent,Silent rs4335205 9 137552398 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4842138 9 137554581 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs6537942 9 137559556 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4842139 9 137563692 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs7044529 9 137568051 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs12554098 9 137573609 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3922982 9 137586995 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4341231 9 137592961 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4529530 9 137594829 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4240702 9 137595859 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4240703 9 137595928 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4319175 9 137596271 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4842145 9 137596949 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3922914 9 137598731 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4548258 9 137599444 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3109687 9 137599992 [T/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4841926 9 137601285 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3128591 9 137602119 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs11103479 9 137610423 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs12004951 9 137612284 [A/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs7875140 9 137613772 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3124300 9 137619862 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3128597 9 137620847 [A/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3109678 9 137625142 [A/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3109677 9 137630568 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3109676 9 137631198 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3128615 9 137641411 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs12686426 9 137642577 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs11103501 9 137646046 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs12004527 9 137648441 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs7849193 9 137650824 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs11103509 9 137654103 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4842157 9 137658608 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4842161 9 137659688 [A/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs10745384 9 137662523 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4842164 9 137665445 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4842165 9 137666414 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4563961 9 137670002 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3124932 9 137672012 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs7849777 9 137672801 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs6537949 9 137673861 [T/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs12005196 9 137677090 [T/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4072077 9 137677489 [T/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3128621 9 137678306 [T/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs11998946 9 137679703 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs9409992 9 137681458 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs28718958 9 137683595 [A/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4842167 9 137687314 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3811159 9 137688657 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3827851 9 137694369 [T/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs4842169 9 137699002 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs11103534 9 137700749 [T/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs11103535 9 137700999 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs13297317 9 137701873 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs10776908 9 137703923 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs7874142 9 137704782 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3827848 9 137707834 [A/G] NM_001278074,NM_000093 COL5A1,COL5A1 EXON Synonymous_T1374T,Synonymous_T1374T rs4841934 9 137707942 [T/C] NM_001278074,NM_000093 COL5A1,COL5A1 Silent,Silent rs3811146 9 137711997 [A/G] NM_001278074,NM_000093,NR_103451 COL5A1,COL5A1,LOC101448202 EXON Synonymous_P1494P,Synonymous_P1494P,Silent rs10858284 9 137713649 [A/G] NM_001278074,NM_000093,NR_103451 COL5A1,COL5A1,LOC101448202 Silent,Silent,Silent rs4842173 9 137718113 [T/C] NM_001278074,NM_000093,NR_103451 COL5A1,COL5A1,LOC101448202 Silent,Silent,Silent rs3128578 9 137722170 [A/G] NM_001278074,NM_000093,NR_103451 COL5A1,COL5A1,LOC101448202 Silent,Silent,Silent rs4842174 9 137722311 [T/C] NM_001278074,NM_000093,NR_103451 COL5A1,COL5A1,LOC101448202 Silent,Silent,Silent rs11103541 9 137722644 [A/G] NM_001278074,NM_000093,NR_103451 COL5A1,COL5A1,LOC101448202 Silent,Silent,Silent rs7864699 9 137724371 [T/C] NM_001278074,NM_000093,NR_103451 COL5A1,COL5A1,LOC101448202 Silent,Silent,Silent rs7849251 9 137727767 [T/C] NM_001278074,NM_000093,NR_103451 COL5A1,COL5A1,LOC101448202 Silent,Silent,Silent rs10858286 9 137730384 [T/C] NM_001278074,NM_000093,NR_103451 COL5A1,COL5A1,LOC101448202 Silent,Silent,Silent rs9410002 9 137730956 [A/G] NM_001278074,NM_000093,NR_103451 COL5A1,COL5A1,LOC101448202 Silent,Silent,Silent rs13946 9 137734232 [T/C] NM_001278074,NM_000093,NR_103451 COL5A1,COL5A1,LOC101448202 EXON Silent,Silent,Silent rs11103544 9 137735043 [T/C] NM_001278074,NM_000093,NR_103451 COL5A1,COL5A1,LOC101448202 EXON Silent,Silent,Silent rs4504708 9 137736544 [T/G] NM_001278074,NM_000093,NR_103451 COL5A1,COL5A1,LOC101448202 EXON Silent,Silent,Silent rs3128575 9 137736650 [T/C] NM_001278074,NM_000093,NR_103451 COL5A1,COL5A1,LOC101448202 EXON Silent,Silent,Silent rs4428739 9 137736729 [T/C] NR_103451 LOC101448202 Silent rs3128574 9 137736913 [T/C] NR_103451 LOC101448202 Silent rs12551466 9 137737438 [A/G] NR_103451 LOC101448202 Silent rs11103545 9 137739980 [T/G] NR_103451 LOC101448202 Silent rs3128570 9 137743309 [A/G] NR_103451 LOC101448202 Silent rs9410004 9 137747707 [T/C] NR_103451 LOC101448202 Silent rs7045674 9 137749015 [T/C] NR_103451 LOC101448202 Silent rs4842175 9 137750215 [T/C] NR_103451 LOC101448202 Silent rs11103552 9 137754467 [A/G] NR_103451 LOC101448202 Silent rs13289166 9 137754738 [T/C] NR_103451 LOC101448202 Silent rs4842176 9 137755163 [T/C] NR_103451 LOC101448202 Silent rs4841940 9 137757212 [T/C] NR_103451 LOC101448202 Silent rs11103559 9 137757545 [T/G] NR_103451 LOC101448202 Silent rs4073505 9 137761104 [A/G] NR_103451 LOC101448202 Silent rs4436197 9 137762857 [A/G] NR_103451 LOC101448202 Silent rs6537952 9 137764457 [A/G] NR_103451 LOC101448202 EXON Silent rs4347056 9 137764945 [T/C] rs3128632 9 137767197 [A/G] rs3124952 9 137771682 [A/G] rs3128626 9 137773556 [A/G] NM_004108,NM_015837 FCN2,FCN2 Silent,Silent rs4370608 9 137774278 [A/G] NM_004108,NM_015837 FCN2,FCN2 Silent,Silent rs7024491 9 137775084 [A/G] NM_004108,NM_015837 FCN2,FCN2 Silent,Silent rs3128624 9 137775139 [A/G] NM_004108,NM_015837 FCN2,FCN2 Silent,Silent rs4520243 9 137775155 [T/C] NM_004108,NM_015837 FCN2,FCN2 EXON Synonymous_R74R,Synonymous_R36R rs12684512 9 137777504 [A/G] NM_004108,NM_015837 FCN2,FCN2 Silent,Silent rs7851696 9 137779091 [T/G] NM_004108,NM_015837 FCN2,FCN2 EXON Missense_A258S,Missense_A220S rs12115600 9 137779733 [A/G] rs11103564 9 137779875 [T/C] rs6537958 9 137780823 [T/C] rs11103567 9 137782277 [T/G] rs10858290 9 137784268 [A/G] rs12004273 9 137786803 [A/G] rs11103569 9 137787248 [A/G] rs4842188 9 137788134 [T/C] rs10776911 9 137789793 [T/C] rs4841944 9 137790376 [T/C] rs4384059 9 137790916 [A/G] rs1537189 9 137800247 [A/G] NM_002003 FCN1 EXON Silent rs3012787 9 137800731 [T/G] NM_002003 FCN1 EXON Silent rs2989735 9 137801416 [T/C] NM_002003 FCN1 EXON Silent rs1071583 9 137801800 [T/C] NM_002003 FCN1 EXON Synonymous_Q275Q rs7863062 9 137806554 [T/C] NM_002003 FCN1 Silent rs2989726 9 137809374 [A/G] NM_002003 FCN1 Silent rs10120023 9 137810259 [T/C] rs2094962 9 137816459 [T/C] rs10858294 9 137824613 [T/G] rs2274838 9 137829465 [T/C] rs7849296 9 137831204 [T/G] rs17570546 9 137834280 [T/C] rs2274844 9 137834828 [T/C] rs1331429 9 137835248 [A/G] rs10119380 9 137837317 [T/C] rs10776914 9 137840809 [T/C] rs10858300 9 137842500 [T/C] rs10858302 9 137846865 [T/C] rs12554353 9 137848020 [T/C] rs10776916 9 137850460 [A/G] rs7851502 9 137852506 [A/G] rs1041498 9 137856025 [T/C] rs4841950 9 137856280 [A/C] rs10858305 9 137858418 [T/C] rs11794589 9 137859032 [A/G] rs7025292 9 137864163 [T/C] rs10858311 9 137880493 [T/C] rs10124926 9 137883639 [A/G] rs2279264 9 137885561 [A/G] rs914392 9 137894409 [T/C] rs7046791 9 137895354 [T/C] rs11103625 9 137899436 [A/G] rs10448312 9 137900695 [T/C] rs7035792 9 137901678 [T/C] rs4841952 9 137904004 [A/C] rs7024007 9 137904052 [T/G] rs11103631 9 137906694 [A/G] rs10776925 9 137907348 [T/C] rs11788133 9 137907399 [A/G] rs4842206 9 137907690 [A/G] rs6537976 9 137909610 [A/G] rs4641145 9 137919491 [T/C] rs7025267 9 137919909 [A/G] rs4842212 9 137925300 [A/C] rs607223 9 137932668 [A/G] rs17493408 9 137933642 [A/G] rs637087 9 137934787 [A/G] rs1009305 9 137937541 [A/G] rs664866 9 137937988 [A/G] rs7048977 9 137938621 [A/G] rs10776927 9 137941500 [A/C] rs17039656 9 137942956 [T/C] rs11103653 9 137943299 [A/G] rs11103657 9 137945419 [A/G] rs12554348 9 137946707 [A/C] rs635470 9 137948742 [T/G] rs521942 9 137963187 [A/C] rs9308281 9 137965410 [T/C] rs3811138 9 137968826 [T/C] NM_014279,NM_006334 OLFM1,OLFM1 Silent,Silent rs546682 9 137970302 [T/C] NM_014279,NM_006334 OLFM1,OLFM1 Silent,Silent rs472048 9 137971918 [T/C] NM_014279,NM_006334 OLFM1,OLFM1 Silent,Silent rs563961 9 137975041 [T/C] NM_014279,NM_006334 OLFM1,OLFM1 Silent,Silent rs572945 9 137978886 [A/C] NM_014279,NM_006334 OLFM1,OLFM1 Silent,Silent rs500461 9 137982127 [T/C] NM_014279,NM_006334,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1,OLFM1 EXON Synonymous_A61A,Synonymous_A61A,Synonymous_A52A,Synonymous_A79A rs660701 9 137982621 [A/G] NM_014279,NM_006334,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1,OLFM1 Silent,Silent,Silent,Silent rs4842220 9 137995557 [T/C] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs899842 9 137995811 [A/C] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs11103672 9 137996712 [A/G] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs7853782 9 137999847 [T/C] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs12001599 9 138001526 [T/C] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs1536661 9 138002096 [T/C] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs1571332 9 138002714 [T/C] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs4842221 9 138002918 [A/G] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs4262379 9 138002994 [T/C] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs943733 9 138004530 [A/G] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs11788357 9 138005260 [T/C] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs11789656 9 138005478 [T/C] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs10858338 9 138006871 [A/C] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs11103681 9 138006947 [A/G] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs11790027 9 138008243 [T/C] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs11103683 9 138009779 [A/C] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 Silent,Silent,Silent rs11103684 9 138012070 [A/G] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 EXON Silent,Silent,Silent rs2298249 9 138012647 [T/C] NM_014279,NM_001282612,NM_001282611 OLFM1,OLFM1,OLFM1 EXON Silent,Silent,Silent rs7035473 9 138013365 [A/G] rs11103685 9 138013614 [A/C] rs7039212 9 138014017 [A/G] rs647128 9 138015713 [A/G] rs11103693 9 138016657 [T/C] rs11103694 9 138016676 [T/C] rs875230 9 138016698 [T/G] rs11103699 9 138017196 [A/G] rs12380578 9 138019726 [T/G] rs745757 9 138022634 [T/C] rs2127693 9 138026115 [T/C] rs2031825 9 138026999 [A/G] rs3860249 9 138027657 [A/G] rs1778993 9 138032691 [T/C] rs11103711 9 138033333 [T/C] rs1778992 9 138036671 [A/G] rs1752664 9 138037129 [T/C] rs11103712 9 138037372 [A/G] rs17495030 9 138038093 [T/C] rs10858353 9 138039129 [T/C] rs1778990 9 138045318 [A/G] rs10858356 9 138050248 [A/G] rs6537988 9 138053217 [A/G] rs6537989 9 138054178 [A/G] rs10124337 9 138054762 [A/G] rs1892001 9 138056027 [T/C] rs1892004 9 138056926 [T/C] rs12379748 9 138058487 [A/G] rs12336130 9 138058737 [T/C] rs7025467 9 138059746 [T/C] rs10858359 9 138059937 [A/C] rs7049140 9 138061259 [A/G] rs12236583 9 138063959 [T/C] rs7034486 9 138065012 [T/C] rs12555792 9 138066092 [A/G] rs2382864 9 138067653 [T/C] rs7047526 9 138068124 [T/G] rs17039857 9 138069240 [A/C] rs10858363 9 138072689 [T/C] rs7849389 9 138074372 [A/G] NR_046107 LOC401557 Silent rs1891988 9 138074576 [A/C] NR_046107 LOC401557 Silent rs1891987 9 138074968 [T/C] NR_046107 LOC401557 Silent rs10858364 9 138076081 [T/G] NR_046107 LOC401557 Silent rs10858365 9 138076167 [T/C] NR_046107 LOC401557 EXON Silent rs10858366 9 138077427 [A/C] NR_046107 LOC401557 EXON Silent rs4842226 9 138078679 [T/C] NR_046107 LOC401557 EXON Silent rs17495922 9 138081976 [A/G] rs11103734 9 138082201 [T/C] rs11103735 9 138082759 [T/C] rs7028628 9 138083351 [T/G] rs1891999 9 138086589 [A/C] rs11793247 9 138087879 [A/G] rs11794621 9 138091594 [T/C] rs7023348 9 138093089 [A/C] rs6538001 9 138093430 [A/G] rs1891996 9 138093775 [T/C] rs1891995 9 138093796 [T/C] rs11103745 9 138097443 [T/C] rs12006325 9 138100852 [A/G] rs7866572 9 138101987 [A/G] rs11103755 9 138102304 [T/C] rs7042583 9 138104368 [T/C] rs1891981 9 138104497 [A/G] rs1891980 9 138105075 [T/C] rs1539677 9 138108252 [T/G] rs7028584 9 138111019 [T/C] rs7022353 9 138114573 [T/C] rs7043651 9 138114837 [A/C] rs7854386 9 138120574 [A/G] rs7875079 9 138123236 [T/C] rs7043655 9 138125763 [A/C] rs12380243 9 138126646 [A/C] rs10858372 9 138127492 [A/G] rs7865457 9 138128536 [A/G] rs7038247 9 138128603 [T/G] rs4842231 9 138129028 [A/C] rs11103764 9 138129933 [A/G] rs1891983 9 138134313 [T/C] rs11103766 9 138135345 [T/C] rs1106259 9 138135660 [A/G] rs1106261 9 138136568 [A/C] rs2382859 9 138137715 [T/G] rs10858374 9 138139506 [T/C] rs4842232 9 138139987 [A/G] rs7033668 9 138143145 [A/G] rs11792631 9 138146809 [A/G] rs11791827 9 138146828 [A/C] rs7858253 9 138149166 [T/C] rs7858399 9 138149317 [T/C] rs5013712 9 138150588 [A/G] rs12347149 9 138151500 [T/G] rs11103782 9 138155396 [T/G] rs7038150 9 138156321 [A/C] rs10858377 9 138159376 [T/C] rs2989741 9 138160077 [A/G] rs1778982 9 138164038 [A/G] rs1778981 9 138165193 [A/G] rs1757350 9 138165503 [A/C] rs11103786 9 138166444 [A/G] rs11103787 9 138170334 [A/C] rs914405 9 138171694 [T/C] rs1106182 9 138172097 [A/G] rs7026842 9 138172789 [A/C] rs11103789 9 138173238 [T/C] rs11103792 9 138173409 [T/G] rs7041675 9 138174163 [T/C] rs1806807 9 138174978 [A/G] rs7874626 9 138175847 [T/C] rs914407 9 138176724 [T/C] rs4842244 9 138180621 [T/C] rs11103796 9 138181228 [T/C] rs10776941 9 138181270 [A/G] rs10745401 9 138182186 [T/C] rs7026673 9 138182939 [T/C] rs7867539 9 138184453 [A/G] rs1757352 9 138186943 [A/G] rs7853412 9 138188447 [T/C] rs7869911 9 138189561 [T/C] rs1778986 9 138189578 [T/C] rs10776946 9 138191389 [T/C] rs10858383 9 138193283 [A/G] rs4841962 9 138195203 [A/C] rs10858385 9 138195529 [T/C] rs3884535 9 138197209 [T/C] rs10858386 9 138197284 [A/G] rs4842247 9 138199317 [A/G] rs7032559 9 138202418 [T/C] rs7047604 9 138210649 [T/C] rs4841964 9 138211368 [A/G] rs4842249 9 138211783 [T/G] rs4842251 9 138219743 [A/G] rs4841967 9 138219780 [T/C] rs11103820 9 138221647 [A/G] rs28522895 9 138222154 [A/G] rs28528098 9 138222314 [T/C] rs12555689 9 138222860 [A/C] rs4842253 9 138229678 [A/C] rs6538017 9 138232307 [T/C] rs7032546 9 138232476 [T/C] rs4842254 9 138236305 [T/C] NM_173520 C9orf62 Silent rs11103828 9 138237120 [T/G] NM_173520 C9orf62 Silent rs6538018 9 138239887 [A/G] rs7039860 9 138241815 [A/G] rs7036094 9 138243149 [T/C] rs9409933 9 138244411 [A/C] rs11789038 9 138245050 [T/G] rs7467652 9 138246910 [T/C] rs7853278 9 138252877 [T/G] rs1571823 9 138258205 [A/G] rs7040000 9 138263731 [T/C] rs11103850 9 138270241 [T/C] rs11789484 9 138275572 [T/G] rs9409884 9 138288052 [T/C] rs10156499 9 138292054 [T/C] rs13294986 9 138292538 [A/G] rs9409948 9 138298164 [T/C] rs6537893 9 138306060 [A/G] rs7019162 9 138312393 [A/G] rs7046908 9 138315859 [T/C] rs12377350 9 138318759 [T/G] rs2384792 9 138324679 [T/C] rs4841983 9 138325937 [T/G] rs10776810 9 138327242 [T/C] rs10858106 9 138332424 [A/G] rs11103015 9 138334237 [A/G] rs10858108 9 138337411 [A/G] rs10776811 9 138340774 [A/G] rs4841986 9 138343253 [A/C] rs895191 9 138345912 [A/G] rs10776815 9 138349162 [A/G] rs4841875 9 138355370 [T/C] NR_038969 PPP1R26-AS1 EXON Silent rs4841876 9 138355410 [A/C] NR_038969 PPP1R26-AS1 EXON Silent rs10745363 9 138357705 [A/G] NR_038969 PPP1R26-AS1 Silent rs17040232 9 138359002 [T/C] NR_038969 PPP1R26-AS1 Silent rs10858115 9 138361170 [T/C] NR_038969 PPP1R26-AS1 Silent rs3748191 9 138363933 [T/G] NR_038969 PPP1R26-AS1 EXON Silent rs2590504 9 138365495 [T/C] rs895192 9 138366254 [T/C] rs3762066 9 138370613 [T/C] rs3789911 9 138372737 [A/G] NM_014811 PPP1R26 Silent rs1412512 9 138373864 [T/C] NM_014811 PPP1R26 Silent rs2254813 9 138375861 [A/G] NM_014811 PPP1R26 EXON Silent rs2254812 9 138375872 [C/G] NM_014811 PPP1R26 EXON Silent rs7026686 9 138383213 [T/G] rs4841991 9 138386597 [A/G] rs3762067 9 138389740 [A/G] NM_144654,NM_001048265 C9orf116,C9orf116 Silent,Silent rs2274651 9 138391517 [A/C] NM_144654,NM_001048265 C9orf116,C9orf116 Silent,Silent rs3748199 9 138395969 [A/G] NR_051970,NR_051969,NR_051968,NR_051967,NM_016034,NR_121579 MRPS2,MRPS2,MRPS2,MRPS2,MRPS2,LOC101928525 EXON Silent,Silent,Silent,Silent,Missense_H294R,Silent rs3748201 9 138396198 [A/G] NR_051970,NR_051969,NR_051968,NR_051967,NM_016034,NR_121579 MRPS2,MRPS2,MRPS2,MRPS2,MRPS2,LOC101928525 EXON Silent,Silent,Silent,Silent,Silent,Silent rs535 9 138396251 [A/G] NR_051970,NR_051969,NR_051968,NR_051967,NM_016034,NR_121579 MRPS2,MRPS2,MRPS2,MRPS2,MRPS2,LOC101928525 EXON Silent,Silent,Silent,Silent,Silent,Silent rs2188210 9 138404555 [T/C] rs739395 9 138406444 [A/G] rs756684 9 138406460 [T/C] rs13290613 9 138406565 [A/G] rs2120943 9 138412171 [A/G] rs13284515 9 138417830 [T/C] NM_001252619,NM_001252617,NM_001252618,NM_002297 LCN1,LCN1,LCN1,LCN1 Silent,Silent,Silent,Silent rs13295025 9 138425308 [A/C] rs210081 9 138428645 [A/G] rs462537 9 138437163 [T/C] rs7045084 9 138437736 [T/C] rs2590498 9 138440045 [A/G] NM_001293189,NR_120603,NM_014582,NM_001293193 OBP2A,OBP2A,OBP2A,OBP2A Silent,Silent,Silent,Silent rs10858121 9 138445655 [A/G] rs895189 9 138445974 [T/C] rs11103062 9 138450193 [T/C] rs10858123 9 138452026 [A/G] rs4841882 9 138452972 [A/G] rs3748206 9 138454301 [T/C] NM_002571,NM_001018048,NM_001018049 PAEP,PAEP,PAEP Silent,Silent,Silent rs783776 9 138455746 [T/C] NM_002571,NM_001018048,NM_001018049 PAEP,PAEP,PAEP Silent,Silent,Silent rs11103063 9 138456727 [T/C] NM_002571,NM_001018048,NM_001018049 PAEP,PAEP,PAEP Silent,Silent,Silent rs3748211 9 138458462 [T/C] NM_002571,NM_001018048,NM_001018049 PAEP,PAEP,PAEP EXON Silent,Silent,Silent rs3748212 9 138458570 [T/C] NM_002571,NM_001018048,NM_001018049 PAEP,PAEP,PAEP EXON Silent,Silent,Silent rs783771 9 138460445 [T/C] rs12238659 9 138463166 [A/G] rs17038696 9 138463888 [A/G] rs697449 9 138467959 [T/G] NR_034017,NR_034016,NR_109814 LINC01502,LINC01502,LINC01502 Silent,Silent,Silent rs10776821 9 138468186 [A/G] NR_034017,NR_034016,NR_109814 LINC01502,LINC01502,LINC01502 Silent,Silent,Silent rs705669 9 138468394 [T/C] NR_034017,NR_034016,NR_109814 LINC01502,LINC01502,LINC01502 Silent,Silent,Silent rs3811133 9 138469460 [A/C] NR_034017,NR_034016,NR_109814 LINC01502,LINC01502,LINC01502 Silent,Silent,Silent rs4842000 9 138469768 [A/C] NR_034017,NR_034016,NR_109814 LINC01502,LINC01502,LINC01502 Silent,Silent,Silent rs10776827 9 138473753 [A/G] NR_034017,NR_034016,NR_109814 LINC01502,LINC01502,LINC01502 Silent,Silent,Silent rs4842007 9 138474785 [T/C] NR_034017,NR_034016,NR_109814 LINC01502,LINC01502,LINC01502 EXON Silent,Silent,Silent rs2297572 9 138475803 [T/C] NR_034017,NR_034016,NR_109814 LINC01502,LINC01502,LINC01502 Silent,Silent,Silent rs7029507 9 138476823 [A/G] NR_034017,NR_034016,NR_109814 LINC01502,LINC01502,LINC01502 Silent,Silent,Silent rs3849218 9 138480486 [T/C] rs2151376 9 138482453 [T/C] rs4842008 9 138482709 [A/G] rs7873626 9 138490710 [T/C] rs10745367 9 138495883 [A/G] rs11103084 9 138496035 [A/G] rs1572049 9 138497067 [T/C] rs4842012 9 138499206 [T/C] rs872005 9 138503416 [T/C] rs11792145 9 138505985 [T/C] rs4841889 9 138510121 [A/G] rs4841890 9 138510283 [A/G] rs11103105 9 138513956 [T/C] rs12336965 9 138515929 [T/G] NM_182974 GLT6D1 EXON Silent rs17040344 9 138516119 [A/G] NM_182974 GLT6D1 EXON Missense_P219S rs12347803 9 138517154 [T/C] NM_182974 GLT6D1 Silent rs1333240 9 138518010 [A/G] NM_182974 GLT6D1 EXON Synonymous_P54P rs11103106 9 138518114 [A/G] NM_182974 GLT6D1 Silent rs10858139 9 138518827 [A/G] NM_182974 GLT6D1 Silent rs7037835 9 138519360 [A/G] NM_182974 GLT6D1 Silent rs1333234 9 138523332 [A/C] NM_182974 GLT6D1 Silent rs10858143 9 138525778 [A/G] NM_182974 GLT6D1 Silent rs11103115 9 138527271 [T/C] NM_182974 GLT6D1 Silent rs11103116 9 138527656 [T/C] NM_182974 GLT6D1 Silent rs7855164 9 138529219 [A/G] NM_182974 GLT6D1 Silent rs1537414 9 138529777 [T/G] NM_182974 GLT6D1 Silent rs13292721 9 138531959 [A/G] rs12684457 9 138533122 [T/C] rs13286163 9 138536400 [A/G] rs11103123 9 138537416 [T/C] rs13293756 9 138540992 [A/G] rs488948 9 138544017 [A/G] rs7020804 9 138545090 [T/C] rs4842019 9 138547454 [T/G] rs541131 9 138552234 [A/G] rs10776838 9 138555161 [A/G] rs488709 9 138559891 [A/G] rs514157 9 138560311 [T/C] rs510386 9 138560560 [A/G] rs480554 9 138567059 [A/G] rs480224 9 138576462 [A/G] rs480422 9 138580775 [A/G] rs528472 9 138580847 [T/C] rs13284789 9 138581671 [T/C] rs10858151 9 138582650 [A/G] rs485779 9 138584199 [T/C] rs484524 9 138586309 [A/G] NM_001012415,NM_001101677 SOHLH1,SOHLH1 Silent,Silent rs558113 9 138591230 [T/C] NM_001012415,NM_001101677 SOHLH1,SOHLH1 Silent,Silent rs523140 9 138592785 [T/C] rs571842 9 138595441 [A/G] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs496503 9 138596974 [A/G] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs487750 9 138603740 [T/C] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs10858154 9 138608747 [A/G] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs492361 9 138610028 [T/C] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs498618 9 138615966 [A/G] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs1537416 9 138617303 [T/C] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs11103147 9 138620891 [A/G] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs10121357 9 138628816 [A/G] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs7020956 9 138640273 [T/C] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs11103161 9 138641780 [A/G] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs7037014 9 138643920 [A/G] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs10735239 9 138644203 [T/C] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs10776844 9 138662309 [A/G] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs10735240 9 138662465 [T/G] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs1318383 9 138668073 [A/G] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs914428 9 138669261 [A/G] NM_020822,NM_001272003 KCNT1,KCNT1 EXON Synonymous_T809T,Synonymous_T764T rs10776845 9 138669976 [A/C] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs1556417 9 138672652 [A/G] NM_020822,NM_001272003 KCNT1,KCNT1 Silent,Silent rs12003206 9 138686456 [T/C] rs7029951 9 138687695 [A/G] rs7852055 9 138695235 [A/G] rs17040481 9 138699437 [A/G] rs12004494 9 138701150 [A/G] NM_015447 CAMSAP1 EXON Silent rs7838 9 138701523 [T/C] NM_015447 CAMSAP1 EXON Silent rs3739465 9 138706844 [A/G] NM_015447 CAMSAP1 Silent rs3739464 9 138707074 [A/G] NM_015447 CAMSAP1 Silent rs12554173 9 138711942 [A/C] NM_015447 CAMSAP1 Silent rs17040507 9 138712775 [A/G] NM_015447 CAMSAP1 EXON Synonymous_P1244P rs10123786 9 138715458 [T/C] NM_015447 CAMSAP1 Silent rs10114302 9 138718981 [A/C] NM_015447 CAMSAP1 Silent rs12335947 9 138742871 [T/C] NM_015447 CAMSAP1 Silent rs7048404 9 138745450 [A/G] NM_015447 CAMSAP1 Silent rs13299821 9 138756168 [T/C] NM_015447 CAMSAP1 Silent rs11792453 9 138761762 [T/C] NM_015447 CAMSAP1 Silent rs11793168 9 138772579 [T/C] NM_015447 CAMSAP1 Silent rs7861677 9 138775419 [A/G] NM_015447 CAMSAP1 Silent rs1009473 9 138777312 [T/C] NM_015447 CAMSAP1 Silent rs3119680 9 138781516 [T/C] NM_015447 CAMSAP1 Silent rs11103212 9 138795733 [A/G] NM_015447 CAMSAP1 Silent rs17040537 9 138797296 [T/C] NM_015447 CAMSAP1 Silent rs4842042 9 138803846 [A/G] rs11103218 9 138813713 [T/C] rs10114289 9 138816252 [A/G] rs4842047 9 138816796 [T/C] rs11103226 9 138817142 [T/C] rs10776854 9 138817178 [A/C] rs7030382 9 138818500 [T/C] rs10858181 9 138822770 [A/G] rs10745376 9 138824310 [T/C] rs6569 9 138825117 [A/C] NM_016172 UBAC1 EXON Silent rs10776856 9 138837113 [T/C] NM_016172 UBAC1 Silent rs2297690 9 138838305 [A/G] NM_016172 UBAC1 Silent rs7868264 9 138850610 [A/G] NM_016172 UBAC1 Silent rs4842059 9 138862766 [A/G] rs17040586 9 138865612 [A/G] rs4841903 9 138867842 [A/G] rs2152174 9 138875850 [T/C] rs4842064 9 138876604 [A/G] rs1475784 9 138877266 [T/C] rs7871935 9 138877704 [A/C] rs7875089 9 138877724 [T/C] rs1475783 9 138878884 [A/G] rs10858194 9 138878949 [A/C] rs870164 9 138880743 [A/G] rs1932090 9 138884700 [T/C] rs10858197 9 138892195 [T/C] rs7869795 9 138893874 [T/C] rs7867262 9 138894400 [A/C] rs11103259 9 138896566 [A/G] rs10858200 9 138900839 [A/G] NM_144653 NACC2 EXON Silent rs2280486 9 138905136 [T/C] NM_144653 NACC2 EXON Synonymous_T388T rs2275107 9 138908250 [T/C] NM_144653 NACC2 EXON Synonymous_P304P rs11103274 9 138908957 [A/G] NM_144653 NACC2 Silent rs10776870 9 138911431 [T/C] NM_144653 NACC2 Silent rs10745379 9 138911484 [A/G] NM_144653 NACC2 Silent rs4842073 9 138913314 [A/C] NM_144653 NACC2 Silent rs4842074 9 138913404 [A/G] NM_144653 NACC2 Silent rs4409473 9 138923780 [T/C] NM_144653 NACC2 Silent rs11103281 9 138930056 [T/C] NM_144653 NACC2 Silent rs7025716 9 138935176 [T/C] NM_144653 NACC2 Silent rs4842084 9 138935470 [A/G] NM_144653 NACC2 Silent rs884559 9 138939662 [T/C] NM_144653 NACC2 Silent rs4842090 9 138940926 [A/C] NM_144653 NACC2 Silent rs4842091 9 138947167 [A/G] NM_144653 NACC2 Silent rs2385188 9 138955201 [T/C] NM_144653 NACC2 Silent rs871095 9 138955246 [T/C] NM_144653 NACC2 Silent rs11103302 9 138958552 [A/G] NM_144653 NACC2 Silent rs10776875 9 138964892 [A/G] NM_144653 NACC2 Silent rs10776877 9 138965868 [T/C] NM_144653 NACC2 Silent rs4842108 9 138972104 [T/C] NM_144653 NACC2 Silent rs12003954 9 138973000 [T/C] NM_144653 NACC2 Silent rs7468351 9 138974889 [T/C] NM_144653 NACC2 Silent rs10776881 9 138978880 [T/C] NM_144653 NACC2 Silent rs1717453 9 138985434 [T/C] NM_144653 NACC2 Silent rs7019243 9 138988568 [T/C] rs7030214 9 138992466 [A/G] rs1164893 9 138999710 [T/C] rs1620864 9 139000752 [A/G] rs1747839 9 139015411 [T/G] rs10858225 9 139016326 [A/G] rs1164884 9 139018847 [A/C] rs1164883 9 139019445 [A/G] rs1164882 9 139020613 [T/C] rs1747846 9 139029017 [T/C] rs1747856 9 139033054 [T/C] rs11103350 9 139035609 [T/G] rs11792632 9 139048452 [T/C] rs17038777 9 139048974 [A/G] rs7858442 9 139049366 [T/G] rs9409914 9 139049385 [T/C] rs912496 9 139050961 [A/G] rs748750 9 139051266 [T/C] rs7025596 9 139051477 [A/G] rs7856051 9 139060656 [A/G] rs4842123 9 139061474 [A/G] rs734819 9 139064119 [A/C] rs11103366 9 139069713 [A/G] rs4842126 9 139077343 [T/C] rs10858244 9 139082796 [A/G] rs11103372 9 139083019 [A/G] rs11103374 9 139087521 [T/C] rs7860634 9 139089679 [A/G] NM_001363746,NM_178138,NM_014564 LHX3,LHX3,LHX3 Silent,Silent,Silent rs3758199 9 139097645 [T/C] rs3780188 9 139098175 [A/G] rs3780189 9 139098216 [T/C] NM_181701 QSOX2 EXON Silent rs3780190 9 139099073 [A/G] NM_181701 QSOX2 EXON Silent rs3824359 9 139105229 [T/C] NM_181701 QSOX2 Silent rs11103387 9 139107879 [T/C] NM_181701 QSOX2 Silent rs10122824 9 139109861 [T/G] NM_181701 QSOX2 Silent rs12684650 9 139110654 [T/C] NM_181701 QSOX2 EXON Synonymous_K319K rs7849585 9 139111870 [T/G] NM_181701 QSOX2 Silent rs12351372 9 139112006 [T/C] NM_181701 QSOX2 Silent rs10858250 9 139119215 [A/G] NM_181701 QSOX2 Silent rs7038554 9 139134981 [A/G] NM_181701 QSOX2 Silent rs28545822 9 139217805 [T/C] NR_026964 DKFZP434A062 EXON Silent rs34940359 9 139218885 [T/G] NR_026964 DKFZP434A062 EXON Silent rs28661870 9 139220876 [A/G] NR_026964 DKFZP434A062 EXON Silent rs28380074 9 139225139 [A/G] NM_001145638,NM_015597 GPSM1,GPSM1 Silent,Silent rs28536668 9 139234512 [T/G] NM_001145638,NM_015597 GPSM1,GPSM1 Silent,Silent rs28539249 9 139240630 [T/C] NM_001145638 GPSM1 Silent rs28439345 9 139243790 [A/C] NM_001145638 GPSM1 Silent rs28642252 9 139245289 [A/G] NM_001145638 GPSM1 Silent rs3812547 9 139252495 [A/G] NM_001145638,NM_001145639,NM_001200003 GPSM1,GPSM1,GPSM1 EXON Synonymous_P617P,Synonymous_P108P,Synonymous_P108P rs10870125 9 139253068 [T/C] NM_001145638,NM_001145639,NM_001200003 GPSM1,GPSM1,GPSM1 EXON Silent,Silent,Silent rs1128905 9 139253839 [T/C] NM_001145638,NM_001145639,NM_001200003 GPSM1,GPSM1,GPSM1 EXON Silent,Silent,Silent rs11145922 9 139254317 [A/G] rs11145937 9 139254805 [A/G] rs10747047 9 139256141 [T/C] rs3829109 9 139256766 [A/G] NM_001080849,NR_073565 DNLZ,DNLZ Silent,Silent rs10121646 9 139257287 [A/G] NM_001080849,NR_073565 DNLZ,DNLZ Silent,Silent rs10870202 9 139257411 [T/C] NM_001080849,NR_073565 DNLZ,DNLZ Silent,Silent rs11145750 9 139259249 [A/G] NM_052813,NM_052814 CARD9,CARD9 Silent,Silent rs9411205 9 139260463 [T/C] NM_052813,NM_052814 CARD9,CARD9 Silent,Silent rs10781496 9 139261086 [A/G] NM_052813,NM_052814 CARD9,CARD9 Silent,Silent rs3812556 9 139261991 [A/G] NM_052813,NM_052814 CARD9,CARD9 Silent,Silent rs10781499 9 139266405 [A/G] NM_052813,NM_052814 CARD9,CARD9 EXON Synonymous_P42P,Synonymous_P42P rs4077515 9 139266496 [T/C] NM_052813,NM_052814 CARD9,CARD9 EXON Missense_S12N,Missense_S12N rs10781500 9 139269338 [T/C] rs3812560 9 139269905 [T/C] rs3812561 9 139270876 [A/G] NM_003086 SNAPC4 EXON Missense_P1448S rs10781507 9 139272058 [A/G] NM_003086 SNAPC4 EXON Synonymous_S1407S rs3829112 9 139273288 [T/C] NM_003086 SNAPC4 EXON Synonymous_E997E rs11145793 9 139274523 [A/G] NM_003086 SNAPC4 Silent rs3812570 9 139275204 [A/C] NM_003086 SNAPC4 EXON Synonymous_V829V rs10781510 9 139279173 [A/G] NM_003086 SNAPC4 EXON Synonymous_V473V rs4266763 9 139289825 [A/G] NM_003086 SNAPC4 EXON Synonymous_D132D rs4076562 9 139295091 [T/C] rs3124994 9 139295282 [A/G] rs563 9 139296485 [A/G] NM_001039708,NM_001039707,NM_006643 ENTR1,ENTR1,ENTR1 EXON Silent,Silent,Silent rs3812577 9 139299637 [T/C] NM_001039708,NM_001039707,NM_006643 ENTR1,ENTR1,ENTR1 EXON Missense_R231Q,Missense_R304Q,Missense_R281Q rs11145917 9 139302200 [T/C] NM_001039708,NM_001039707,NM_006643 ENTR1,ENTR1,ENTR1 Silent,Silent,Silent rs11145930 9 139304016 [T/C] NM_001039708,NM_001039707,NM_006643 ENTR1,ENTR1,ENTR1 Silent,Silent,Silent rs10870144 9 139306467 [T/C] NM_001282944,NM_015160,NM_001282946 PMPCA,PMPCA,PMPCA EXON Silent,Synonymous_Y30Y,Silent rs11145974 9 139316744 [T/C] NM_001282944,NM_015160,NM_001282946 PMPCA,PMPCA,PMPCA Silent,Silent,Silent rs9548 9 139317823 [T/C] NM_001282944,NM_015160,NM_001282946 PMPCA,PMPCA,PMPCA EXON Silent,Silent,Silent rs1130635 9 139317869 [T/C] NM_001282944,NM_015160,NM_001282946 PMPCA,PMPCA,PMPCA EXON Silent,Silent,Silent rs1128877 9 139323201 [A/G] NM_001318502,NM_019892 INPP5E,INPP5E EXON Silent,Silent rs8413 9 139323311 [T/C] NM_001318502,NM_019892 INPP5E,INPP5E EXON Silent,Silent rs10870194 9 139327034 [A/G] NM_001318502,NM_019892 INPP5E,INPP5E EXON Synonymous_C427C,Synonymous_G428G rs10781542 9 139327439 [A/G] NM_001318502,NM_019892 INPP5E,INPP5E EXON Synonymous_T416T,Synonymous_T416T rs1127162 9 139335206 [T/C] NM_014866,NM_001276418 SEC16A,SEC16A EXON Silent,Silent rs1127152 9 139335599 [A/G] NM_014866,NM_001276418 SEC16A,SEC16A EXON Silent,Silent rs3812589 9 139335879 [A/G] NM_014866,NM_001276418 SEC16A,SEC16A EXON Silent,Silent rs12684275 9 139343666 [A/G] NM_014866,NM_001276418 SEC16A,SEC16A Silent,Silent rs17610266 9 139350595 [A/G] NM_014866,NM_001276418 SEC16A,SEC16A EXON Synonymous_F1858F,Synonymous_F1858F rs13300554 9 139357939 [A/G] NM_014866,NM_001276418 SEC16A,SEC16A EXON Synonymous_I1541I,Synonymous_I1541I rs3812594 9 139368953 [A/G] NM_014866,NM_001276418 SEC16A,SEC16A EXON Missense_R1039C,Missense_R1039C rs3812595 9 139369062 [T/C] NM_014866,NM_001276418 SEC16A,SEC16A EXON Synonymous_L1002L,Synonymous_L1002L rs17567909 9 139369212 [A/G] NM_014866,NM_001276418 SEC16A,SEC16A EXON Synonymous_P952P,Synonymous_P952P rs10781497 9 139371234 [A/G] NM_014866,NM_001276418 SEC16A,SEC16A EXON Synonymous_D278D,Synonymous_D278D rs10870070 9 139374952 [A/C] NM_014866,NM_001276418 SEC16A,SEC16A Silent,Silent rs4378078 9 139375962 [A/G] NM_014866,NM_001276418 SEC16A,SEC16A Silent,Silent rs1139057 9 139380320 [T/C] NM_152571 C9orf163 EXON Silent rs9314867 9 139387846 [T/C] rs6563 9 139389184 [A/G] NM_017617 NOTCH1 EXON Silent rs2229974 9 139391636 [A/G] NM_017617 NOTCH1 EXON Synonymous_D2185D rs3124596 9 139401504 [A/G] NM_017617 NOTCH1 Silent rs3812605 9 139403102 [T/C] NM_017617 NOTCH1 Silent rs3124599 9 139403770 [A/G] NM_017617 NOTCH1 Silent rs11145766 9 139404895 [T/C] NM_017617 NOTCH1 Silent rs3124602 9 139406491 [A/G] NM_017617 NOTCH1 Silent rs2229971 9 139407932 [A/G] NM_017617 NOTCH1 EXON Synonymous_N755N rs3812609 9 139408892 [T/C] NM_017617 NOTCH1 Silent rs3124607 9 139414839 [A/G] NM_017617 NOTCH1 Silent rs4489420 9 139418260 [A/G] NM_017617 NOTCH1 EXON Synonymous_N104N rs10870079 9 139424343 [A/G] NM_017617 NOTCH1 Silent rs13290979 9 139425634 [A/G] NM_017617 NOTCH1 Silent rs11145770 9 139427066 [T/C] NM_017617 NOTCH1 Silent rs3013300 9 139431057 [T/C] NM_017617 NOTCH1 Silent rs3013302 9 139431874 [A/G] NM_017617 NOTCH1 Silent rs3013309 9 139443253 [A/G] NR_121577 NALT1 Silent rs710411 9 139443956 [A/G] NR_121577 NALT1 Silent rs885446 9 139443989 [T/C] NR_121577 NALT1 Silent rs1058233 9 139444102 [T/C] NR_121577 NALT1 EXON Silent rs7034799 9 139456212 [T/G] rs7849014 9 139457506 [T/C] rs10870085 9 139468185 [T/G] rs10870088 9 139477521 [T/C] rs944758 9 139483954 [T/C] rs4880055 9 139487092 [T/C] rs11145791 9 139500617 [T/C] rs10870094 9 139500886 [A/G] rs7041089 9 139501085 [A/G] rs4880106 9 139501325 [A/G] rs7852910 9 139511247 [A/C] NR_135288 LINC01451 EXON Silent rs12685728 9 139513139 [T/C] rs12378485 9 139513538 [T/G] rs7025588 9 139514080 [A/G] rs4880107 9 139517440 [A/G] rs12376605 9 139518718 [A/G] rs7863705 9 139518965 [T/C] rs914737 9 139522101 [A/G] rs10870101 9 139526086 [T/C] rs10747029 9 139534703 [T/C] rs10735657 9 139535714 [T/G] rs7854618 9 139540385 [A/C] rs7871194 9 139544437 [A/C] NR_135132 HSPC324 Silent rs4880117 9 139552461 [T/C] NR_135132 HSPC324 Silent rs1332793 9 139556771 [T/C] NR_046367 EGFL7 Silent rs2297538 9 139564668 [A/G] NR_046367,NR_045111,NM_016215,NR_045110,NM_201446 EGFL7,EGFL7,EGFL7,EGFL7,EGFL7 EXON Silent,Silent,Missense_V153I,Silent,Missense_V153I rs11558192 9 139566889 [A/G] NR_046367,NR_045111,NM_016215,NR_045110,NM_201446 EGFL7,EGFL7,EGFL7,EGFL7,EGFL7 EXON Silent,Silent,Silent,Silent,Silent rs4880119 9 139568047 [A/G] NM_001012727,NM_006412 AGPAT2,AGPAT2 EXON Silent,Silent rs10217363 9 139570617 [T/C] NM_001012727,NM_006412 AGPAT2,AGPAT2 Silent,Silent rs9411216 9 139575487 [A/G] NM_001012727,NM_006412 AGPAT2,AGPAT2 Silent,Silent rs1889047 9 139578880 [A/G] NM_001012727,NM_006412 AGPAT2,AGPAT2 Silent,Silent rs10156573 9 139590097 [A/G] rs4880127 9 139590934 [A/G] rs2385891 9 139596420 [T/G] rs10870112 9 139598108 [A/G] rs11793385 9 139607966 [T/C] NM_152421 FAM69B Silent rs7029239 9 139615549 [A/G] NM_152421 FAM69B Silent rs11793962 9 139617379 [A/G] NM_152421 FAM69B Silent rs6874 9 139617836 [T/C] NM_152421 FAM69B EXON Synonymous_N302N rs11999246 9 139623701 [T/C] rs10118736 9 139633733 [T/C] NM_001001712 LCN10 EXON Silent rs10118741 9 139633778 [A/C] NM_001001712 LCN10 EXON Silent rs9886752 9 139634495 [A/G] NM_001001712 LCN10 EXON Nonsense_Q161X rs2811724 9 139638740 [A/C] NM_198946 LCN6 Silent rs7848644 9 139639004 [A/G] NM_198946 LCN6 Silent rs12342559 9 139641732 [T/G] NM_198946,NR_033913 LCN6,LOC100128593 EXON Silent,Silent rs1360879 9 139643023 [A/G] NR_033913 LOC100128593 EXON Silent rs1108607 9 139648721 [T/C] rs2248077 9 139649273 [A/G] NM_178469,NM_001345934 LCN8,LCN8 Silent,Silent rs11145868 9 139653133 [T/C] rs2297723 9 139656706 [A/C] NM_203347 LCN15 EXON Missense_S152A rs4880142 9 139660402 [T/C] rs12684893 9 139674527 [A/G] rs2784054 9 139679717 [A/C] rs2811787 9 139685136 [A/G] rs3739950 9 139686247 [A/G] NM_032928 TMEM141 Silent rs2784034 9 139690738 [G/C] rs1055995 9 139690840 [A/G] NM_001039374 CCDC183 EXON Silent rs945386 9 139693596 [T/C] NM_001039374 CCDC183 EXON Missense_M38T rs945387 9 139693992 [T/C] NM_001039374 CCDC183 Silent rs4546744 9 139694521 [T/G] NM_001039374 CCDC183 EXON Missense_L113R rs7859194 9 139694569 [A/C] NM_001039374 CCDC183 EXON Missense_D129A rs7851646 9 139699195 [T/C] NM_001039374,NR_024580 CCDC183,CCDC183-AS1 EXON Silent,Silent rs2811795 9 139700605 [T/C] NM_001039374,NR_024580 CCDC183,CCDC183-AS1 EXON Missense_W342R,Silent rs2254143 9 139701108 [A/C] NM_001039374,NR_024580 CCDC183,CCDC183-AS1 EXON Missense_N421T,Silent rs2484661 9 139709976 [T/C] NM_024718,NM_001173988,NM_001173989 RABL6,RABL6,RABL6 Silent,Silent,Silent rs7856666 9 139711726 [A/G] NM_024718,NM_001173988,NM_001173989 RABL6,RABL6,RABL6 Silent,Silent,Silent rs2811754 9 139719671 [T/C] NM_024718,NM_001173988,NM_001173989 RABL6,RABL6,RABL6 Silent,Silent,Silent rs2811751 9 139721513 [T/C] NM_024718,NM_001173988,NM_001173989 RABL6,RABL6,RABL6 Silent,Silent,Silent rs2811749 9 139725227 [T/C] NM_024718,NM_001173988,NM_001173989 RABL6,RABL6,RABL6 Silent,Silent,Silent rs2811748 9 139726239 [A/G] NM_024718,NM_001173988,NM_001173989 RABL6,RABL6,RABL6 EXON Synonymous_G175G,Synonymous_G175G,Synonymous_G175G rs7858150 9 139728504 [A/G] NM_024718,NM_001173988,NM_001173989 RABL6,RABL6,RABL6 EXON Silent,Silent,Silent rs2811744 9 139730129 [T/C] NM_024718,NM_001173988 RABL6,RABL6 Silent,Silent rs12001160 9 139735232 [A/G] NM_024718,NM_001173988 RABL6,RABL6 EXON Silent,Silent rs2077581 9 139736198 [A/C] rs12554208 9 139737804 [T/C] NM_001080482 AJM1 Silent rs12555238 9 139743497 [T/C] NM_001287342,NM_001135861,NM_001287343,NR_109807,NR_109808,NM_014172 PHPT1,PHPT1,PHPT1,PHPT1,PHPT1,PHPT1 EXON Silent,Silent,Silent,Silent,Silent,Silent rs35489193 9 139744984 [T/C] NM_001287342,NM_001135861,NM_001287343,NR_109807,NR_109808,NM_014172 PHPT1,PHPT1,PHPT1,PHPT1,PHPT1,PHPT1 EXON Silent,Synonymous_G104G,Synonymous_G105G,Silent,Silent,Silent rs10123375 9 139746992 [A/G] NM_206920 MAMDC4 Silent rs11791235 9 139750505 [A/C] NM_206920 MAMDC4 EXON Missense_L542I rs2236544 9 139754110 [A/G] NM_206920 MAMDC4 Silent rs12550889 9 139756883 [A/G] NM_001281297,NM_001281298,NM_003792,NM_001281299 EDF1,EDF1,EDF1,EDF1 EXON Silent,Silent,Silent,Silent rs11145909 9 139764148 [A/G] rs10781520 9 139779462 [A/G] rs17243613 9 139779629 [A/G] rs2784075 9 139792926 [T/C] NM_021138 TRAF2 Silent rs10870140 9 139796419 [T/C] NM_021138 TRAF2 Silent rs10119096 9 139801932 [T/C] NM_021138 TRAF2 Silent rs4880158 9 139804679 [T/C] NM_021138 TRAF2 Silent rs10781522 9 139815053 [A/G] NM_021138 TRAF2 Silent rs4880073 9 139817353 [A/G] NM_021138 TRAF2 Silent rs17250680 9 139820363 [A/G] NM_021138 TRAF2 EXON Silent rs7852970 9 139820421 [A/G] NM_021138 TRAF2 EXON Silent rs3750512 9 139821068 [A/G] rs1040246 9 139822036 [G/C] rs7019752 9 139823670 [T/C] rs10115595 9 139830787 [A/C] rs6560652 9 139830940 [T/C] rs4880169 9 139834195 [T/C] rs7040705 9 139836362 [A/G] NM_018998 FBXW5 Silent rs2292926 9 139837071 [A/G] NM_018998 FBXW5 EXON Synonymous_L201L rs884112 9 139841558 [A/G] rs1879011 9 139842262 [T/C] rs4880172 9 139844151 [A/C] rs884218 9 139847570 [T/C] NM_178536 LCN12 Silent rs7030823 9 139848717 [T/C] NM_178536 LCN12 Silent rs2292921 9 139849624 [A/G] NM_178536 LCN12 Silent rs868102 9 139850119 [A/G] rs10781528 9 139854099 [A/G] rs11145951 9 139860264 [T/C] rs11793787 9 139860631 [T/C] rs10114487 9 139869600 [T/C] rs3814499 9 139869914 [A/G] rs4880179 9 139872048 [A/G] NM_000954 PTGDS EXON Synonymous_T6T rs35556170 9 139873436 [T/C] NM_000954 PTGDS Silent rs34184410 9 139873437 [T/C] NM_000954 PTGDS Silent rs35848246 9 139873962 [T/C] NM_000954 PTGDS Silent rs6926 9 139876141 [A/C] NM_000954 PTGDS EXON Silent rs13306 9 139876154 [A/G] NM_000954 PTGDS EXON Silent rs2049043 9 139877129 [A/C] rs35615223 9 139877584 [T/G] NM_207510 LCNL1 EXON Silent rs7029565 9 139878317 [T/C] NM_207510 LCNL1 Silent rs4880082 9 139878828 [T/C] NM_207510 LCNL1 Silent rs17578859 9 139879170 [A/G] NM_207510 LCNL1 EXON Missense_A68T rs10870158 9 139885820 [A/C] rs10781530 9 139885948 [A/C] rs13795 9 139890129 [A/G] NM_004669 CLIC3 EXON Synonymous_P38P rs2292923 9 139890130 [T/G] NM_004669 CLIC3 EXON Missense_P38H rs7031895 9 139900586 [A/G] rs7857948 9 139901681 [T/C] rs7036668 9 139901891 [A/G] NM_212533,NM_001606 ABCA2,ABCA2 EXON Silent,Silent rs2271864 9 139909428 [T/C] NM_212533,NM_001606 ABCA2,ABCA2 EXON Synonymous_T1303T,Synonymous_T1273T rs12348881 9 139911983 [T/G] NM_212533,NM_001606 ABCA2,ABCA2 EXON Synonymous_A821A,Synonymous_A791A rs908832 9 139912484 [A/G] NM_212533,NM_001606 ABCA2,ABCA2 EXON Synonymous_D709D,Synonymous_D679D rs2090625 9 139912498 [A/C] NM_212533,NM_001606 ABCA2,ABCA2 EXON Missense_F705V,Missense_F675V rs35902749 9 139917595 [A/G] NM_212533,NM_001606 ABCA2,ABCA2 Silent,Silent rs34496415 9 139921814 [A/G] NM_212533,NM_001606 ABCA2,ABCA2 Silent,Silent rs4880191 9 139923937 [T/C] NM_207511 C9orf139 Silent rs13301354 9 139924637 [T/C] NM_207511,NM_004479 C9orf139,FUT7 EXON Silent,Silent rs11145973 9 139925459 [A/G] NM_207511,NM_004479 C9orf139,FUT7 EXON Silent,Synonymous_N244N rs10732706 9 139926960 [T/C] NM_207511,NM_004479 C9orf139,FUT7 EXON Silent,Silent rs12551220 9 139927182 [A/G] NM_207511,NM_004479 C9orf139,FUT7 EXON Silent,Silent rs12337910 9 139929435 [A/G] NM_207511 C9orf139 EXON Missense_K168E rs1138628 9 139932211 [A/C] rs7038280 9 139933244 [T/C] rs6605 9 139934020 [A/G] NM_015392 NPDC1 EXON Silent rs6604 9 139934107 [A/G] NM_015392 NPDC1 EXON Silent rs7043416 9 139934859 [T/C] NM_015392 NPDC1 EXON Synonymous_A246A rs13289619 9 139936141 [A/G] NM_015392 NPDC1 Silent rs3829107 9 139938681 [A/G] NM_015392 NPDC1 Silent rs7861020 9 139947473 [T/G] NM_203468,NM_001246 ENTPD2,ENTPD2 Silent,Silent rs3750517 9 139958296 [T/C] NM_178448 SAPCD2 EXON Silent rs34755670 9 139958645 [A/C] NM_178448 SAPCD2 EXON Silent rs4880195 9 139959853 [T/C] NM_178448 SAPCD2 Silent rs4073309 9 139972322 [T/G] NM_207309 UAP1L1 Silent rs7037849 9 139973820 [T/C] NM_207309 UAP1L1 EXON Missense_A319V rs7851870 9 139977351 [A/C] NM_207309 UAP1L1 EXON Silent rs10119378 9 139977963 [A/G] NM_207309 UAP1L1 EXON Silent rs1018330 9 139980385 [A/C] NR_027447 MAN1B1-DT EXON Silent rs968733 9 139981627 [A/G] NM_016219,NR_045720,NR_045721 MAN1B1,MAN1B1,MAN1B1 EXON Missense_N59S,Silent,Silent rs10870177 9 139987350 [T/C] NM_016219,NR_045720,NR_045721 MAN1B1,MAN1B1,MAN1B1 Silent,Silent,Silent rs7871579 9 139990530 [T/C] NM_016219,NR_045720,NR_045721 MAN1B1,MAN1B1,MAN1B1 Silent,Silent,Silent rs4880200 9 139994102 [A/G] NM_016219,NR_045720,NR_045721 MAN1B1,MAN1B1,MAN1B1 Silent,Silent,Silent rs4880201 9 139995065 [A/C] NM_016219,NR_045720,NR_045721 MAN1B1,MAN1B1,MAN1B1 Silent,Silent,Silent rs4880091 9 140002989 [T/C] NM_016219,NR_045720,NR_045721 MAN1B1,MAN1B1,MAN1B1 EXON Synonymous_D682D,Silent,Silent rs4567 9 140003427 [A/G] NM_016219,NR_045720,NR_045721 MAN1B1,MAN1B1,MAN1B1 EXON Silent,Silent,Silent rs7853336 9 140003640 [A/G] rs11145996 9 140004341 [T/C] rs13631 9 140006202 [A/G] NM_013379 DPP7 EXON Synonymous_L404L rs10870180 9 140006491 [T/C] NM_013379 DPP7 Silent rs6560660 9 140010517 [A/G] rs4880094 9 140018138 [T/C] rs9411311 9 140018892 [A/C] rs2301363 9 140034431 [T/C] NM_000832,NM_001185091,NM_001185090,NM_007327,NM_021569 GRIN1,GRIN1,GRIN1,GRIN1,GRIN1 Silent,Silent,Silent,Silent,Silent rs4880215 9 140037029 [A/C] NM_000832,NM_001185091,NM_001185090,NM_007327,NM_021569 GRIN1,GRIN1,GRIN1,GRIN1,GRIN1 Silent,Silent,Silent,Silent,Silent rs10870198 9 140042320 [A/G] NM_000832,NM_001185091,NM_001185090,NM_007327,NM_021569 GRIN1,GRIN1,GRIN1,GRIN1,GRIN1 Silent,Silent,Silent,Silent,Silent rs11794201 9 140054136 [T/C] NM_000832,NM_001185091,NM_001185090,NM_007327,NM_021569 GRIN1,GRIN1,GRIN1,GRIN1,GRIN1 Silent,Silent,Silent,Silent,Silent rs12686185 9 140054530 [T/G] NM_000832,NM_001185091,NM_001185090,NM_007327,NM_021569 GRIN1,GRIN1,GRIN1,GRIN1,GRIN1 Silent,Silent,Silent,Silent,Silent rs10747050 9 140055876 [A/G] NM_000832,NM_001185091,NM_001185090,NM_007327,NM_021569 GRIN1,GRIN1,GRIN1,GRIN1,GRIN1 Silent,Silent,Silent,Silent,Silent rs7853409 9 140061446 [A/G] NM_000832,NM_001185091,NM_001185090,NM_007327,NM_021569 GRIN1,GRIN1,GRIN1,GRIN1,GRIN1 Silent,Silent,Silent,Silent,Silent rs4074426 9 140068342 [A/G] rs28560209 9 140073120 [T/C] NM_013366 ANAPC2 Silent rs28451678 9 140075719 [T/C] NM_013366 ANAPC2 Silent rs28665875 9 140076439 [T/C] NM_013366 ANAPC2 Silent rs28624882 9 140080851 [A/G] NM_013366 ANAPC2 Silent rs28491420 9 140081705 [T/C] NM_013366 ANAPC2 Silent rs13292648 9 140085991 [T/G] rs28412124 9 140088574 [A/G] NM_001128228 TPRN Silent rs28417902 9 140088630 [A/G] NM_001128228 TPRN Silent rs4880220 9 140093188 [T/G] NM_001128228 TPRN Silent rs6606564 9 140101687 [A/G] NM_014434,NM_001144026,NM_001144027,NM_001144028 NDOR1,NDOR1,NDOR1,NDOR1 Silent,Silent,Silent,Silent rs34383296 9 140106538 [A/G] NM_014434,NM_001144026,NM_001144027,NM_001144028 NDOR1,NDOR1,NDOR1,NDOR1 Silent,Silent,Silent,Silent rs7390663 9 140110274 [T/C] NM_014434,NM_001144026,NM_001144027,NM_001144028 NDOR1,NDOR1,NDOR1,NDOR1 Silent,Silent,Silent,Silent rs7389948 9 140112169 [T/G] NM_014434,NM_001144026,NM_001144027,NM_001144028 NDOR1,NDOR1,NDOR1,NDOR1 EXON Silent,Silent,Silent,Silent rs7023977 9 140121761 [A/G] rs28371983 9 140126744 [T/G] NM_001177317,NM_001177316,NM_080877 SLC34A3,SLC34A3,SLC34A3 Silent,Silent,Silent rs34796681 9 140127725 [T/C] NM_001177317,NM_001177316,NM_080877 SLC34A3,SLC34A3,SLC34A3 EXON Synonymous_L209L,Synonymous_L209L,Synonymous_L209L rs28407527 9 140128085 [T/C] NM_001177317,NM_001177316,NM_080877 SLC34A3,SLC34A3,SLC34A3 EXON Synonymous_L253L,Synonymous_L253L,Synonymous_L253L rs35699762 9 140128644 [A/G] NM_001177317,NM_001177316,NM_080877 SLC34A3,SLC34A3,SLC34A3 EXON Missense_G337S,Missense_G337S,Missense_G337S rs9775080 9 140132388 [A/G] rs9722600 9 140133600 [T/C] rs9722604 9 140133719 [T/C] rs4073074 9 140139184 [A/G] NM_001001710 FAM166A EXON Synonymous_Y219Y rs11522281 9 140140401 [A/C] NM_001001710 FAM166A Silent rs11497277 9 140141794 [A/G] NM_001001710 FAM166A Silent rs11535662 9 140143801 [T/C] rs1142749 9 140144215 [A/G] rs9802576 9 140144649 [A/G] rs28631372 9 140148051 [A/G] rs28455716 9 140148189 [T/G] rs11562620 9 140164250 [T/C] NM_015456 NELFB Silent rs11534410 9 140165510 [T/C] NM_015456 NELFB Silent rs28527282 9 140167730 [A/G] NM_015456 NELFB EXON Silent rs8281 9 140167877 [T/G] NM_015456 NELFB EXON Silent rs13301565 9 140177040 [T/A] NM_017723 TOR4A EXON Silent rs28474868 9 140187577 [T/C] rs34230770 9 140188045 [A/C] rs7850758 9 140188225 [A/G] rs6606575 9 140191981 [T/C] rs28583601 9 140194903 [T/C] NM_001004354 NRARP EXON Silent rs28719051 9 140200755 [A/G] rs13288421 9 140202194 [T/C] NM_017820 EXD3 Silent rs28434345 9 140204360 [A/G] NM_017820 EXD3 Silent rs9695629 9 140205159 [T/G] NM_017820 EXD3 Silent rs28374197 9 140205269 [T/C] NM_017820 EXD3 Silent rs7389783 9 140207278 [T/C] NM_017820 EXD3 Silent rs7027646 9 140221582 [A/G] NM_017820 EXD3 Silent rs28767597 9 140232871 [T/C] NM_017820 EXD3 Silent rs7852496 9 140237016 [T/G] NM_017820 EXD3 Silent rs7848746 9 140238885 [A/G] NM_017820 EXD3 Silent rs7022335 9 140240310 [A/C] NM_017820 EXD3 Silent rs28688712 9 140247365 [T/C] NM_017820 EXD3 Silent rs28417430 9 140249041 [T/C] NM_017820 EXD3 Silent rs7389423 9 140250818 [T/C] NM_017820 EXD3 EXON Missense_R220Q rs28542538 9 140257610 [T/C] NM_017820 EXD3 Silent rs11533157 9 140262218 [T/C] NM_017820,NR_104598,NM_001286823 EXD3,EXD3,EXD3 Silent,Silent,Silent rs9775457 9 140266929 [A/C] NM_017820,NR_104598,NM_001286823 EXD3,EXD3,EXD3 Silent,Silent,Silent rs28488438 9 140268976 [T/C] NM_017820,NR_104598,NM_001286823 EXD3,EXD3,EXD3 Silent,Silent,Silent rs28494047 9 140271414 [T/C] NM_017820,NR_104598,NM_001286823 EXD3,EXD3,EXD3 Silent,Silent,Silent rs28735138 9 140274164 [A/G] NM_017820,NR_104598,NM_001286823 EXD3,EXD3,EXD3 Silent,Silent,Silent rs11516132 9 140274255 [A/G] NM_017820,NR_104598,NM_001286823 EXD3,EXD3,EXD3 Silent,Silent,Silent rs7390551 9 140277524 [T/C] NM_017820,NR_104598,NM_001286823 EXD3,EXD3,EXD3 Silent,Silent,Silent rs11522293 9 140279703 [T/C] NM_017820,NR_104598,NM_001286823 EXD3,EXD3,EXD3 Silent,Silent,Silent rs11559483 9 140283341 [A/G] NM_017820,NR_104598,NM_001286823 EXD3,EXD3,EXD3 Silent,Silent,Silent rs11507687 9 140289761 [A/G] NM_017820,NR_104598,NM_001286823,NR_104599 EXD3,EXD3,EXD3,EXD3 EXON Missense_R17C,Silent,Missense_R17C,Silent rs7043936 9 140291031 [T/C] NM_017820,NR_104598,NM_001286823,NR_104599 EXD3,EXD3,EXD3,EXD3 Silent,Silent,Silent,Silent rs7469429 9 140291708 [T/C] NM_017820,NR_104598,NM_001286823,NR_104599 EXD3,EXD3,EXD3,EXD3 Silent,Silent,Silent,Silent rs11516126 9 140301447 [T/C] NM_017820,NR_104598,NM_001286823,NR_104599 EXD3,EXD3,EXD3,EXD3 Silent,Silent,Silent,Silent rs7029134 9 140305091 [A/C] NM_017820,NR_104598,NM_001286823,NR_104599 EXD3,EXD3,EXD3,EXD3 Silent,Silent,Silent,Silent rs11516128 9 140311092 [A/G] NM_017820,NR_104598,NM_001286823,NR_104599 EXD3,EXD3,EXD3,EXD3 Silent,Silent,Silent,Silent rs6422889 9 140313025 [T/C] NM_017820,NR_104598,NM_001286823,NR_104599 EXD3,EXD3,EXD3,EXD3 Silent,Silent,Silent,Silent rs6606588 9 140316819 [A/G] NM_017820,NR_104598,NM_001286823,NR_104599 EXD3,EXD3,EXD3,EXD3 Silent,Silent,Silent,Silent rs13288824 9 140317084 [A/C] NM_017820,NR_104598,NM_001286823,NR_104599 EXD3,EXD3,EXD3,EXD3 Silent,Silent,Silent,Silent rs7029543 9 140318758 [A/G] NM_001256068,NM_006647,NM_001256067 NOXA1,NOXA1,NOXA1 Silent,Silent,Silent rs11522284 9 140320172 [T/C] NM_001256068,NM_006647,NM_001256067 NOXA1,NOXA1,NOXA1 Silent,Silent,Silent rs11534413 9 140321666 [T/C] NM_001256068,NM_006647,NM_001256067 NOXA1,NOXA1,NOXA1 Silent,Silent,Silent rs11534415 9 140325962 [A/G] NM_001256068,NM_006647,NM_001256067 NOXA1,NOXA1,NOXA1 Silent,Silent,Silent rs34155071 9 140327663 [T/C] NM_001256068,NM_006647,NM_001256067 NOXA1,NOXA1,NOXA1 EXON Missense_P230L,Missense_P286L,Missense_P286L rs28649497 9 140329141 [T/C] NM_198585,NM_001033113 ENTPD8,ENTPD8 EXON Silent,Silent rs9414731 9 140331833 [A/G] NM_198585,NM_001033113 ENTPD8,ENTPD8 Silent,Silent rs6606582 9 140332478 [A/G] NM_198585,NM_001033113 ENTPD8,ENTPD8 EXON Missense_L62P,Missense_L62P rs9722391 9 140333859 [A/G] NM_198585,NM_001033113 ENTPD8,ENTPD8 Silent,Silent rs11516129 9 140339091 [C/G] rs28504158 9 140340708 [A/C] rs28699612 9 140344328 [A/G] NM_001130970,NM_001130971,NM_001178064,NM_015537,NM_001130969 NSMF,NSMF,NSMF,NSMF,NSMF Silent,Silent,Silent,Silent,Silent rs9410194 9 140348401 [T/C] NM_001130970,NM_001130971,NM_001178064,NM_015537,NM_001130969 NSMF,NSMF,NSMF,NSMF,NSMF Silent,Silent,Silent,Silent,Silent rs4962237 9 140358581 [T/C] NM_152286,NM_001098537 PNPLA7,PNPLA7 EXON Missense_D1050N,Missense_D1075N rs28859278 9 140370160 [T/C] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs10116708 9 140376668 [A/G] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs11137287 9 140382705 [T/C] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs10123340 9 140389538 [A/G] NM_152286,NM_001098537 PNPLA7,PNPLA7 EXON Synonymous_L667L,Synonymous_L692L rs13283256 9 140389613 [T/C] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs4962232 9 140392494 [T/C] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs1891629 9 140396212 [T/C] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs7037200 9 140399983 [T/C] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs11791683 9 140400527 [T/C] NM_152286,NM_001098537 PNPLA7,PNPLA7 EXON Missense_G387S,Missense_G412S rs17065442 9 140408189 [A/C] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs2480105 9 140410881 [T/C] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs11137410 9 140414410 [T/C] NM_152286,NM_001098537 PNPLA7,PNPLA7 EXON Missense_R323Q,Missense_R348Q rs12236403 9 140417507 [T/C] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs821304 9 140418677 [T/G] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs28875616 9 140422452 [A/G] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs13293120 9 140427037 [T/G] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs11137428 9 140429256 [A/G] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs10867123 9 140432318 [A/G] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs1099298 9 140436548 [T/C] NM_152286,NM_001098537 PNPLA7,PNPLA7 Silent,Silent rs13299241 9 140445079 [A/C] rs1048370 9 140446806 [T/C] NM_032477 MRPL41 EXON Synonymous_L91L rs821324 9 140447805 [T/G] rs11137129 9 140448679 [A/G] rs10110 9 140449582 [A/C] NM_001346372,NM_001346389,NM_001346371,NM_001346391,NM_001346390,NM_001346392,NM_001346370,NM_001346388,NM_001346387,NM_001346393,NM_001346374,NM_138778,NM_001346375,NM_001346380,NM_001346385,NM_001346379,NM_001346384,NM_001346382,NM_001346381,NM_001346395,NM_001346383,NM_001346386,NM_001346396,NM_001346373,NM_001346394,NM_001346376,NM_001346377,NM_001346378 DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1105221 9 140450159 [T/C] NM_001346372,NM_001346389,NM_001346371,NM_001346391,NM_001346390,NM_001346392,NM_001346370,NM_001346388,NM_001346387,NM_001346393,NM_001346374,NM_138778,NM_001346375,NM_001346380,NM_001346385,NM_001346379,NM_001346384,NM_001346382,NM_001346381,NM_001346395,NM_001346383,NM_001346386,NM_001346396,NM_001346373,NM_001346394,NM_001346376,NM_001346377,NM_001346378 DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12344692 9 140451408 [T/C] NM_001346372,NM_001346389,NM_001346371,NM_001346391,NM_001346390,NM_001346392,NM_001346370,NM_001346388,NM_001346387,NM_001346393,NM_001346374,NM_138778,NM_001346375,NM_001346380,NM_001346385,NM_001346379,NM_001346384,NM_001346382,NM_001346381,NM_001346395,NM_001346383,NM_001346386,NM_001346396,NM_001346373,NM_001346394,NM_001346376,NM_001346377,NM_001346378 DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11137131 9 140455663 [T/C] NM_001346372,NM_001346389,NM_001346371,NM_001346391,NM_001346390,NM_001346392,NM_001346370,NM_001346388,NM_001346387,NM_001346393,NM_001346374,NM_138778,NM_001346375,NM_001346380,NM_001346385,NM_001346379,NM_001346384,NM_001346382,NM_001346381,NM_001346395,NM_001346383,NM_001346386,NM_001346396,NM_001346373,NM_001346394,NM_001346376,NM_001346377,NM_001346378 DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12683290 9 140463729 [T/C] NM_001346372,NM_001346389,NM_001346371,NM_001346391,NM_001346390,NM_001346392,NM_001346370,NM_001346388,NM_001346387,NM_001346393,NM_001346374,NM_138778,NM_001346375,NM_001346380,NM_001346385,NM_001346379,NM_001346384,NM_001346382,NM_001346381,NM_001346395,NM_001346383,NM_001346386,NM_001346396,NM_001346373,NM_001346394,NM_001346376,NM_001346377,NM_001346378 DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs950078 9 140466816 [A/G] NM_001346372,NM_001346389,NM_001346371,NM_001346391,NM_001346390,NM_001346392,NM_001346370,NM_001346388,NM_001346387,NM_001346393,NM_001346374,NM_138778,NM_001346375,NM_001346380,NM_001346385,NM_001346379,NM_001346384,NM_001346382,NM_001346381,NM_001346395,NM_001346383,NM_001346386,NM_001346396,NM_001346373,NM_001346394,NM_001346376,NM_001346377,NM_001346378 DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs821314 9 140468828 [T/C] NM_001346372,NM_001346389,NM_001346371,NM_001346391,NM_001346390,NM_001346392,NM_001346370,NM_001346388,NM_001346387,NM_001346393,NM_001346374,NM_138778,NM_001346375,NM_001346380,NM_001346385,NM_001346379,NM_001346384,NM_001346382,NM_001346381,NM_001346395,NM_001346383,NM_001346386,NM_001346396,NM_001346373,NM_001346394,NM_001346376,NM_001346377,NM_001346378 DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7,DPH7 EXON Missense_G158R,Silent,Missense_G158R,Silent,Silent,Silent,Missense_G158R,Silent,Silent,Silent,Missense_G158R,Missense_G158R,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Missense_G24R,Silent,Silent,Silent,Silent rs2259657 9 140483076 [A/G] NM_138462 ZMYND19 Silent rs11789062 9 140498789 [A/G] rs4962227 9 140507688 [T/C] NM_152285,NM_001317968 ARRDC1,ARRDC1 Silent,Silent rs2149562 9 140511280 [A/G] NR_122035,NR_122036 ARRDC1-AS1,ARRDC1-AS1 Silent,Silent rs821311 9 140512640 [A/G] NR_122035,NR_122036 ARRDC1-AS1,ARRDC1-AS1 EXON Silent,Silent rs1006498 9 140514826 [T/C] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs10867031 9 140515875 [A/G] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs2987621 9 140526439 [A/G] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs11137167 9 140542378 [T/C] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs12349983 9 140554505 [A/C] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs17496354 9 140566936 [T/C] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs2501557 9 140569260 [T/C] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs10732688 9 140581700 [T/G] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs975978 9 140587156 [A/G] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs4634736 9 140601645 [A/G] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs3125785 9 140602887 [T/C] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs10118305 9 140604518 [T/C] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs7039441 9 140605334 [T/C] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs7037783 9 140610042 [T/C] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs3812497 9 140611436 [T/C] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 EXON Synonymous_P148P,Synonymous_P117P,Synonymous_P117P,Synonymous_P148P,Synonymous_P148P,Synonymous_P148P rs9314636 9 140613053 [T/C] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs3125782 9 140623027 [T/C] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs10867056 9 140624798 [T/G] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs10124805 9 140625189 [A/G] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs9410127 9 140629940 [T/C] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs3123510 9 140636333 [A/G] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs11137198 9 140638534 [A/G] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 EXON Missense_A388T,Missense_A357T,Missense_A357T,Missense_A381T,Missense_A388T,Missense_A388T rs6559221 9 140642331 [T/C] NM_001354611,NM_001354259,NM_001354612,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent,Silent,Silent rs7034879 9 140661826 [T/G] NM_001354259,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent rs4587409 9 140663554 [A/C] NM_001354259,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent rs7868455 9 140671147 [T/C] NM_001354259,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1 EXON Synonymous_N592N,Synonymous_N616N,Synonymous_N623N,Synonymous_N623N rs12004293 9 140677678 [T/C] NM_001354259,NM_001354263,NM_024757,NM_001145527 EHMT1,EHMT1,EHMT1,EHMT1 Silent,Silent,Silent,Silent rs12002515 9 140680245 [A/G] NM_001354259,NM_001354263,NM_024757,NR_147508 EHMT1,EHMT1,EHMT1,LOC651337 EXON Silent,Silent,Silent,Silent rs4487855 9 140682841 [T/C] NM_001354259,NM_001354263,NM_024757,NR_147508 EHMT1,EHMT1,EHMT1,LOC651337 EXON Silent,Silent,Silent,Silent rs7852475 9 140698856 [T/C] NM_001354263,NM_024757 EHMT1,EHMT1 Silent,Silent rs7028850 9 140700868 [A/G] NM_001354263,NM_024757 EHMT1,EHMT1 Silent,Silent rs11789684 9 140706127 [A/G] NM_001354263,NM_024757 EHMT1,EHMT1 Silent,Silent rs11137244 9 140707889 [A/G] NM_001354263,NM_024757 EHMT1,EHMT1 EXON Synonymous_V1022V,Synonymous_V1029V rs12344858 9 140720117 [T/G] NM_001354263,NM_024757 EHMT1,EHMT1 Silent,Silent rs4526432 9 140734161 [T/C] rs7390989 9 140738306 [A/G] rs10867083 9 140751501 [A/G] rs7389298 9 140755119 [T/C] rs7862101 9 140756825 [T/C] rs11137281 9 140760661 [T/C] rs11137284 9 140761465 [T/C] rs9314641 9 140762652 [T/C] NR_121583 LOC100133077 EXON Silent rs7025557 9 140767745 [T/C] NR_121583 LOC100133077 Silent rs6559243 9 140768119 [T/C] NR_121583 LOC100133077 Silent rs12350732 9 140770440 [A/G] NR_121583 LOC100133077 Silent rs12551367 9 140771066 [T/C] NR_121583 LOC100133077 Silent rs4072563 9 140777105 [A/C] NR_121583,NM_001243812,NM_000718 LOC100133077,CACNA1B,CACNA1B Silent,Silent,Silent rs11137293 9 140782621 [A/G] NR_121583,NM_001243812,NM_000718 LOC100133077,CACNA1B,CACNA1B Silent,Silent,Silent rs4076712 9 140786918 [T/C] NR_121583,NM_001243812,NM_000718 LOC100133077,CACNA1B,CACNA1B EXON Silent,Silent,Silent rs7021325 9 140790265 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs7855166 9 140805683 [A/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs12236550 9 140838033 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs11137321 9 140847971 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs4427247 9 140853948 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs10780195 9 140866689 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs12352971 9 140866826 [T/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs11137331 9 140878616 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B EXON Synonymous_V561V,Synonymous_V561V rs1073731 9 140890373 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs7047822 9 140903633 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs7028989 9 140911670 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs7019274 9 140924465 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs7852364 9 140928675 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs7865267 9 140938075 [T/C] NM_001243812,NM_000718,NR_121582 CACNA1B,CACNA1B,LOC101928786 EXON Silent,Silent,Silent rs1547504 9 140942057 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs12377346 9 140953555 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B EXON Missense_E1500K,Missense_E1500K rs6559263 9 140956338 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs1123190 9 140958350 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs7023278 9 140961469 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs10867100 9 140962687 [T/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs1993430 9 140964758 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs7874239 9 140968222 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs11137363 9 140969391 [T/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs7032692 9 140969853 [A/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs10780200 9 140969861 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs936249 9 140971315 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs2290582 9 140972887 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs2168525 9 140989389 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs10867107 9 141001866 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs7357733 9 141003946 [T/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs1378954 9 141005656 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs9314645 9 141005753 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs2229948 9 141008876 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B EXON Synonymous_F1861F,Synonymous_F1861F rs4876928 9 141009015 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs2739257 9 141010457 [A/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs2606356 9 141011524 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs2606357 9 141011581 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs2606358 9 141011771 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs2739260 9 141012064 [A/G] NM_001243812,NM_000718 CACNA1B,CACNA1B Silent,Silent rs2229949 9 141016531 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B EXON Silent,Silent rs3750507 9 141017211 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B EXON Silent,Silent rs3750508 9 141017240 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B EXON Silent,Silent rs3750510 9 141017352 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B EXON Silent,Silent rs9777369 9 141018423 [T/C] NM_001243812,NM_000718 CACNA1B,CACNA1B EXON Silent,Silent rs9410073 9 141022295 [A/G] rs11137376 9 141025328 [A/C] rs11137379 9 141027939 [A/G] rs9314655 9 141066491 [A/G] NR_027156 TUBBP5 Silent rs10076494 5 38139 [T/C] rs10039735 5 48534 [T/C] rs6869386 5 81437 [T/C] rs341260 5 90199 [T/C] rs389363 5 99784 [A/G] NM_052909 PLEKHG4B Silent rs3893856 5 111163 [A/G] NM_052909 PLEKHG4B Silent rs10073501 5 113577 [T/C] NM_052909 PLEKHG4B Silent rs10042022 5 114071 [A/C] NM_052909 PLEKHG4B Silent rs341267 5 118406 [T/C] NM_052909 PLEKHG4B Silent rs12523402 5 140636 [A/G] NM_052909 PLEKHG4B EXON Missense_A428T rs11741126 5 141659 [T/C] NM_052909 PLEKHG4B Silent rs11949577 5 143197 [A/G] NM_052909 PLEKHG4B EXON Missense_G505S rs13436090 5 143534 [A/G] NM_052909 PLEKHG4B EXON Missense_R576H rs6554830 5 156287 [A/G] NM_052909 PLEKHG4B EXON Synonymous_A770A rs11749678 5 161292 [T/C] NM_052909 PLEKHG4B Silent rs29675 5 163769 [A/G] NM_052909 PLEKHG4B Silent rs6885136 5 173200 [T/C] NM_052909 PLEKHG4B Silent rs4956987 5 174106 [A/G] NM_052909 PLEKHG4B EXON Missense_R1432Q rs2059860 5 180325 [T/G] NM_052909 PLEKHG4B Silent rs7700533 5 180646 [T/C] NM_052909 PLEKHG4B Silent rs7717970 5 181660 [T/G] NM_052909 PLEKHG4B EXON Synonymous_G1478G rs11133847 5 181762 [A/G] NM_052909 PLEKHG4B EXON Synonymous_R1512R rs4956990 5 183134 [A/G] NM_052909 PLEKHG4B EXON Silent rs13176160 5 183401 [A/G] NM_052909 PLEKHG4B EXON Silent rs4956991 5 183516 [A/G] NM_052909 PLEKHG4B EXON Silent rs1053477 5 184393 [T/C] NM_052909 PLEKHG4B EXON Silent rs4956993 5 184702 [A/G] NM_052909 PLEKHG4B EXON Silent rs1053478 5 184750 [A/G] NM_052909 PLEKHG4B EXON Silent rs1053479 5 184760 [A/G] NM_052909 PLEKHG4B EXON Silent rs6554947 5 185160 [T/G] NM_052909 PLEKHG4B EXON Silent rs7727015 5 185498 [T/C] NM_052909 PLEKHG4B EXON Silent rs6861289 5 186095 [T/C] NM_052909 PLEKHG4B EXON Silent rs12514423 5 187218 [T/C] NM_052909 PLEKHG4B EXON Silent rs6887262 5 188380 [T/C] NM_052909 PLEKHG4B EXON Silent rs17559144 5 188719 [T/C] NM_052909 PLEKHG4B EXON Silent rs6874933 5 188747 [T/C] NM_052909 PLEKHG4B EXON Silent rs6883247 5 188918 [A/G] NM_052909 PLEKHG4B EXON Silent rs29681 5 190639 [T/C] rs4956994 5 200868 [A/G] rs9312960 5 204082 [A/C] rs1054174 5 204952 [T/C] NM_145265 CCDC127 EXON Silent rs6884639 5 205320 [A/G] NM_145265 CCDC127 EXON Silent rs9763161 5 207618 [A/G] NM_145265 CCDC127 Silent rs6861223 5 208959 [T/C] NM_145265 CCDC127 Silent rs2115273 5 217921 [A/G] NM_145265 CCDC127 Silent rs6555055 5 226160 [A/C] NM_001294332,NM_004168,NM_001330758 SDHA,SDHA,SDHA EXON Synonymous_R159R,Synonymous_R207R,Synonymous_R207R rs9312983 5 232969 [A/G] NM_001294332,NM_004168,NM_001330758 SDHA,SDHA,SDHA Silent,Silent,Silent rs11133943 5 246152 [T/C] NM_001294332,NM_004168,NM_001330758 SDHA,SDHA,SDHA Silent,Silent,Silent rs10055993 5 264296 [A/C] rs1541822 5 269234 [T/G] rs6896163 5 303686 [A/G] NM_001267558,NM_001267559,NM_001267556,NM_013232,NM_001267557 PDCD6,PDCD6,PDCD6,PDCD6,PDCD6 Silent,Silent,Silent,Silent,Silent rs16900804 5 305595 [T/C] NM_001267558,NM_001267559,NM_001267556,NM_013232,NM_001267557,NM_020731,NM_001242412 PDCD6,PDCD6,PDCD6,PDCD6,PDCD6,AHRR,AHRR Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2672770 5 309060 [A/C] NM_001267558,NM_001267559,NM_001267556,NM_013232,NM_001267557,NM_020731,NM_001242412 PDCD6,PDCD6,PDCD6,PDCD6,PDCD6,AHRR,AHRR Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3756712 5 309096 [A/C] NM_001267558,NM_001267559,NM_001267556,NM_013232,NM_001267557,NM_020731,NM_001242412 PDCD6,PDCD6,PDCD6,PDCD6,PDCD6,AHRR,AHRR Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2244029 5 311478 [T/C] NM_001267558,NM_001267559,NM_001267556,NM_013232,NM_001267557,NM_020731,NM_001242412 PDCD6,PDCD6,PDCD6,PDCD6,PDCD6,AHRR,AHRR EXON Synonymous_I76I,Silent,Synonymous_I144I,Synonymous_I146I,Synonymous_I78I,Silent,Silent rs4957020 5 314346 [T/C] NM_001267558,NM_001267559,NM_001267556,NM_013232,NM_001267557,NM_020731,NM_001242412 PDCD6,PDCD6,PDCD6,PDCD6,PDCD6,AHRR,AHRR Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1574220 5 314518 [T/C] NM_001267558,NM_001267559,NM_001267556,NM_013232,NM_001267557,NM_020731,NM_001242412 PDCD6,PDCD6,PDCD6,PDCD6,PDCD6,AHRR,AHRR Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7736 5 314935 [T/C] NM_001267558,NM_001267559,NM_001267556,NM_013232,NM_001267557,NM_020731,NM_001242412 PDCD6,PDCD6,PDCD6,PDCD6,PDCD6,AHRR,AHRR EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4957023 5 336952 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs2013782 5 354051 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs2672737 5 356381 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs6555205 5 360543 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs11745733 5 360739 [A/G] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs908114 5 371958 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs1877840 5 374748 [A/G] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs11133994 5 376994 [A/G] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs2721020 5 379198 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs6899226 5 393377 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs11741523 5 403069 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs6869655 5 403286 [A/G] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs10054612 5 403929 [A/G] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs11740668 5 404623 [A/G] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs2672715 5 404804 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs732111 5 407230 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs2671898 5 409760 [T/G] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs11746079 5 410980 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs17562461 5 411361 [A/G] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs4956936 5 412694 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs10072668 5 422752 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs4987100 5 422873 [T/C] NM_020731,NM_001242412 AHRR,AHRR EXON Synonymous_D161D,Synonymous_D161D rs2672777 5 423385 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs12188164 5 428236 [A/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs957792 5 429989 [A/G] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs768479 5 431196 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs2720997 5 433654 [A/G] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs2672724 5 433952 [T/C] NM_020731,NM_001242412 AHRR,AHRR Silent,Silent rs2672779 5 435055 [T/G] NM_020731,NM_001242412 AHRR,AHRR EXON Silent,Silent rs349583 5 436665 [A/G] NM_020731,NM_001242412 AHRR,AHRR EXON Silent,Silent rs10078 5 438102 [T/G] NM_020731,NM_001242412 AHRR,AHRR EXON Silent,Silent rs2241598 5 438564 [T/C] rs10035653 5 442790 [A/G] NR_126522 EXOC3-AS1 EXON Silent rs12654521 5 446577 [A/G] NM_007277 EXOC3 Silent rs2672722 5 453567 [A/G] NM_007277 EXOC3 EXON Synonymous_E149E rs2721010 5 456915 [A/G] NM_007277 EXOC3 Silent rs11749327 5 457261 [A/C] NM_007277 EXOC3 Silent rs2561666 5 463898 [A/G] NM_007277 EXOC3 Silent rs2561667 5 464153 [T/C] NM_007277 EXOC3 Silent rs2247114 5 475104 [A/G] NM_001284351,NM_004174,NR_125375 SLC9A3,SLC9A3,SLC9A3-AS1 EXON Missense_C790R,Missense_C799R,Silent rs2278254 5 477968 [A/G] NM_001284351,NM_004174,NR_125375 SLC9A3,SLC9A3,SLC9A3-AS1 Silent,Silent,Silent rs2241597 5 480509 [A/G] NM_001284351,NM_004174,NR_125375 SLC9A3,SLC9A3,SLC9A3-AS1 EXON Silent,Silent,Silent rs2303736 5 488298 [A/G] NM_001284351,NM_004174 SLC9A3,SLC9A3 Silent,Silent rs6869782 5 488862 [T/C] NM_001284351,NM_004174 SLC9A3,SLC9A3 Silent,Silent rs12657631 5 490237 [T/C] NM_001284351,NM_004174 SLC9A3,SLC9A3 Silent,Silent rs6870920 5 491906 [A/G] NM_001284351,NM_004174 SLC9A3,SLC9A3 EXON Synonymous_G164G,Synonymous_G164G rs10475268 5 492922 [T/G] NM_001284351,NM_004174 SLC9A3,SLC9A3 Silent,Silent rs4957043 5 494956 [A/G] NM_001284351,NM_004174 SLC9A3,SLC9A3 Silent,Silent rs6868535 5 495377 [T/C] NM_001284351,NM_004174 SLC9A3,SLC9A3 Silent,Silent rs13359853 5 497277 [A/G] NM_001284351,NM_004174 SLC9A3,SLC9A3 Silent,Silent rs4957044 5 499071 [T/G] NM_001284351,NM_004174 SLC9A3,SLC9A3 Silent,Silent rs13177896 5 501544 [T/C] NM_001284351,NM_004174 SLC9A3,SLC9A3 Silent,Silent rs6864158 5 506051 [A/G] NM_001284351,NM_004174 SLC9A3,SLC9A3 Silent,Silent rs4956949 5 514785 [A/G] NM_001284351,NM_004174 SLC9A3,SLC9A3 Silent,Silent rs2434389 5 516808 [A/G] NM_001284351,NM_004174 SLC9A3,SLC9A3 Silent,Silent rs772654 5 539310 [T/G] rs772655 5 539460 [T/C] rs9800013 5 542023 [A/G] rs17563576 5 560476 [A/G] rs6555357 5 560923 [A/G] rs2672027 5 566782 [A/C] rs3853657 5 567246 [T/C] rs16900912 5 572663 [T/C] rs3915384 5 573395 [A/C] rs4541696 5 581053 [A/G] rs11739663 5 594083 [T/C] rs4045344 5 595870 [T/G] rs9313132 5 598237 [A/G] rs9313133 5 598289 [T/C] rs16900924 5 606384 [T/C] NR_103444 LOC100996325 Silent rs4956954 5 607388 [A/G] NR_103444 LOC100996325 Silent rs2335953 5 611254 [A/G] NR_103444 LOC100996325 Silent rs3810857 5 611753 [T/C] NR_103444 LOC100996325 EXON Silent rs1697952 5 614963 [A/G] NM_018140 CEP72 Silent rs7726839 5 618586 [A/G] NM_018140 CEP72 Silent rs16900931 5 620486 [T/G] NM_018140 CEP72 Silent rs7711748 5 636589 [T/C] NM_018140 CEP72 Silent rs868649 5 640705 [A/G] NM_018140 CEP72 EXON Missense_T509A rs12518227 5 652034 [T/C] NM_018140 CEP72 Silent rs2458815 5 653343 [T/C] NM_018140 CEP72 EXON Silent rs1689671 5 659605 [A/G] rs3762954 5 662955 [T/C] NM_007030 TPPP EXON Silent rs16900955 5 664952 [A/G] NM_007030 TPPP EXON Silent rs1697963 5 665280 [T/C] NM_007030 TPPP EXON Synonymous_S199S rs1709541 5 666776 [T/C] NM_007030 TPPP Silent rs6555398 5 667247 [A/G] NM_007030 TPPP Silent rs3792723 5 670706 [A/G] NM_007030 TPPP Silent rs3828569 5 670745 [A/G] NM_007030 TPPP Silent rs413666 5 673408 [T/C] NM_007030 TPPP Silent rs1709544 5 674921 [T/C] NM_007030 TPPP Silent rs394465 5 676806 [T/C] NM_007030 TPPP Silent rs392088 5 677718 [A/G] NM_007030 TPPP Silent rs6862648 5 685504 [A/G] NM_007030 TPPP Silent rs436354 5 730271 [A/G] NM_001351303,NR_147095,NR_147096 ZDHHC11B,ZDHHC11B,ZDHHC11B Silent,Silent,Silent rs461714 5 788646 [A/G] rs588820 5 818658 [A/G] NM_024786 ZDHHC11 Silent rs3747738 5 819671 [T/C] NM_024786 ZDHHC11 EXON Missense_R372H rs3747737 5 821726 [T/C] NM_024786 ZDHHC11 Silent rs2335582 5 825338 [A/G] NM_024786 ZDHHC11 EXON Missense_H322Y rs4518448 5 840717 [A/C] NM_024786 ZDHHC11 EXON Missense_V226G rs3747733 5 851046 [A/G] NM_024786 ZDHHC11 EXON Silent rs3810859 5 851582 [A/G] rs7702532 5 852207 [A/G] rs10475433 5 862682 [A/G] rs16877782 5 864053 [A/G] NM_001009877,NM_023924,NR_134296,NM_001317951 BRD9,BRD9,BRD9,BRD9 EXON Silent,Silent,Silent,Silent rs7702501 5 865411 [A/C] NM_001009877,NM_023924,NR_134296,NM_001317951 BRD9,BRD9,BRD9,BRD9 Silent,Silent,Silent,Silent rs17568860 5 874001 [A/G] NM_001009877,NM_023924,NR_134296,NM_001317951 BRD9,BRD9,BRD9,BRD9 Silent,Silent,Silent,Silent rs16880430 5 881087 [A/C] NM_001009877,NM_023924,NR_134296,NM_001317951 BRD9,BRD9,BRD9,BRD9 Silent,Silent,Silent,Silent rs3747740 5 884251 [A/G] NM_001009877,NM_023924,NR_134296,NM_001317951 BRD9,BRD9,BRD9,BRD9 Silent,Silent,Silent,Silent rs10072022 5 884439 [A/C] NM_001009877,NM_023924,NR_134296,NM_001317951 BRD9,BRD9,BRD9,BRD9 Silent,Silent,Silent,Silent rs6555568 5 894439 [A/G] NM_001166260,NM_004237 TRIP13,TRIP13 Silent,Silent rs920980 5 896983 [A/G] NM_001166260,NM_004237 TRIP13,TRIP13 Silent,Silent rs12518024 5 904374 [T/G] NM_001166260,NM_004237 TRIP13,TRIP13 Silent,Silent rs6887705 5 911236 [T/C] NM_004237 TRIP13 Silent rs14389 5 917878 [A/G] NM_004237 TRIP13 EXON Silent rs7714178 5 918523 [T/C] rs10068712 5 927625 [T/G] rs7728035 5 944298 [A/G] rs16903665 5 946418 [A/C] rs10058912 5 948117 [T/G] rs4957112 5 956671 [T/C] rs16867926 5 959224 [A/G] rs16868012 5 959731 [T/C] rs16868701 5 964250 [A/G] rs12653180 5 965618 [T/G] rs10071835 5 969285 [A/G] rs2289827 5 979148 [T/C] rs10065177 5 981019 [T/C] rs4975533 5 988510 [T/C] NR_104614,NR_104615 LOC100506688,LOC100506688 EXON Silent,Silent rs6882848 5 992509 [T/C] NR_104614,NR_104615 LOC100506688,LOC100506688 Silent,Silent rs326046 5 992859 [A/C] NR_104614,NR_104615 LOC100506688,LOC100506688 Silent,Silent rs13160308 5 994615 [T/C] NR_104614,NR_104615 LOC100506688,LOC100506688 Silent,Silent rs7443724 5 996696 [A/C] NR_104614,NR_104615 LOC100506688,LOC100506688 Silent,Silent rs374361 5 999338 [T/C] rs4975586 5 1000782 [A/G] rs4078802 5 1010083 [A/G] NM_001271082,NM_033120 NKD2,NKD2 Silent,Silent rs6869901 5 1011149 [A/G] NM_001271082,NM_033120 NKD2,NKD2 Silent,Silent rs12518095 5 1012446 [T/C] NM_001271082,NM_033120 NKD2,NKD2 Silent,Silent rs16870593 5 1013269 [A/G] NM_001271082,NM_033120 NKD2,NKD2 Silent,Silent rs16870629 5 1015063 [T/C] NM_001271082,NM_033120 NKD2,NKD2 Silent,Silent rs4975577 5 1032032 [T/C] NM_001271082,NM_033120 NKD2,NKD2 Silent,Silent rs10866472 5 1039278 [T/C] rs12517757 5 1040657 [T/C] rs4975526 5 1041105 [A/G] rs1058508 5 1051687 [T/C] NM_006598 SLC12A7 EXON Silent rs3810853 5 1051918 [A/G] NM_006598 SLC12A7 EXON Silent rs3810854 5 1052360 [T/C] NM_006598 SLC12A7 EXON Silent rs2241606 5 1057615 [A/G] NM_006598 SLC12A7 EXON Synonymous_S999S rs7722287 5 1063998 [A/G] NM_006598 SLC12A7 EXON Synonymous_Y900Y rs737154 5 1065399 [T/C] NM_006598 SLC12A7 EXON Synonymous_V812V rs7737804 5 1066615 [A/G] NM_006598 SLC12A7 Silent rs7714914 5 1074921 [A/G] NM_006598 SLC12A7 Silent rs11951420 5 1076245 [A/G] NM_006598 SLC12A7 Silent rs4975684 5 1078642 [A/C] NM_006598 SLC12A7 Silent rs6865765 5 1081702 [A/G] NM_006598 SLC12A7 EXON Synonymous_P429P rs4526148 5 1081767 [T/C] NM_006598 SLC12A7 EXON Missense_A408T rs6864667 5 1090534 [A/G] NM_006598 SLC12A7 Silent rs4975593 5 1097281 [T/C] NM_006598 SLC12A7 Silent rs6879835 5 1102134 [A/C] NM_006598 SLC12A7 Silent rs6894574 5 1103495 [T/C] NM_006598 SLC12A7 Silent rs4580814 5 1113244 [T/G] rs4285270 5 1113556 [T/C] rs11954838 5 1115240 [T/G] rs13171076 5 1120954 [T/C] rs13162116 5 1121954 [T/C] rs4975614 5 1124560 [A/G] rs11951225 5 1129746 [A/G] rs4594899 5 1132216 [A/G] rs4076817 5 1134166 [A/G] rs4076818 5 1134914 [A/G] rs7379059 5 1143298 [T/C] rs7726442 5 1157313 [T/C] rs7719062 5 1169044 [T/G] rs7702150 5 1169112 [A/G] rs13181306 5 1170323 [A/G] rs4975536 5 1176601 [A/G] NR_109911 CTD-3080P12.3 EXON Silent rs4246740 5 1186086 [T/C] rs6554634 5 1186121 [A/G] rs4246736 5 1186853 [A/G] rs4460173 5 1187180 [T/C] rs4975599 5 1188837 [T/C] rs4975596 5 1189347 [T/C] rs7719875 5 1190088 [A/G] rs6884486 5 1190440 [A/G] rs10060236 5 1191061 [A/G] rs11747247 5 1200573 [T/G] rs13183296 5 1200882 [T/C] rs10064354 5 1201599 [T/C] rs4975607 5 1202817 [A/C] NM_001003841 SLC6A19 Silent rs13159461 5 1203437 [A/G] NM_001003841 SLC6A19 Silent rs10072823 5 1205636 [T/C] NM_001003841 SLC6A19 Silent rs12658538 5 1206462 [T/C] NM_001003841 SLC6A19 Silent rs7444093 5 1211556 [T/C] NM_001003841 SLC6A19 Silent rs7727745 5 1212357 [A/C] NM_001003841 SLC6A19 Silent rs7732589 5 1213668 [A/G] NM_001003841 SLC6A19 EXON Missense_V252I rs11133684 5 1215474 [A/G] NM_001003841 SLC6A19 Silent rs35329108 5 1216900 [A/G] NM_001003841 SLC6A19 Silent rs6554666 5 1217471 [A/G] NM_001003841 SLC6A19 Silent rs4975628 5 1220032 [A/G] NM_001003841 SLC6A19 Silent rs12513763 5 1221199 [T/C] NM_001003841 SLC6A19 Silent rs10060827 5 1223062 [T/G] NM_001003841 SLC6A19 EXON Silent rs9418 5 1225121 [T/C] NM_001003841 SLC6A19 EXON Silent rs7704882 5 1225434 [T/C] rs7724858 5 1225703 [A/G] NM_182632 SLC6A18 EXON Synonymous_G37G rs10042399 5 1235790 [A/G] NM_182632 SLC6A18 Silent rs7445640 5 1236212 [T/G] NM_182632 SLC6A18 Silent rs7447815 5 1240757 [C/G] NM_182632 SLC6A18 EXON Nonsense_Y319X rs6554684 5 1240848 [A/C] NM_182632 SLC6A18 Silent rs10043584 5 1241908 [T/C] NM_182632 SLC6A18 Silent rs13361701 5 1243427 [T/G] NM_182632 SLC6A18 Silent rs4075202 5 1243475 [A/C] NM_182632 SLC6A18 Silent rs4073918 5 1244425 [T/C] NM_182632 SLC6A18 EXON Missense_P478L rs2853690 5 1253744 [A/G] NM_198253,NM_001193376,NR_149163,NR_149162 TERT,TERT,TERT,TERT EXON Silent,Silent,Silent,Silent rs2736122 5 1257621 [A/G] NM_198253,NM_001193376,NR_149163,NR_149162 TERT,TERT,TERT,TERT Silent,Silent,Silent,Silent rs2075786 5 1266310 [A/G] NM_198253,NM_001193376,NR_149163,NR_149162 TERT,TERT,TERT,TERT Silent,Silent,Silent,Silent rs10069690 5 1279790 [T/C] NM_198253,NM_001193376,NR_149163,NR_149162 TERT,TERT,TERT,TERT Silent,Silent,Silent,Silent rs2736100 5 1286516 [A/C] NM_198253,NM_001193376,NR_149163,NR_149162 TERT,TERT,TERT,TERT Silent,Silent,Silent,Silent rs2853677 5 1287194 [A/G] NM_198253,NM_001193376,NR_149163,NR_149162 TERT,TERT,TERT,TERT Silent,Silent,Silent,Silent rs2853672 5 1292983 [A/C] NM_198253,NM_001193376,NR_149163,NR_149162 TERT,TERT,TERT,TERT Silent,Silent,Silent,Silent rs2736098 5 1294086 [T/C] NM_198253,NM_001193376,NR_149163,NR_149162 TERT,TERT,TERT,TERT EXON Synonymous_A305A,Synonymous_A305A,Silent,Silent rs4975612 5 1300310 [T/G] rs4635969 5 1308552 [A/G] rs4975616 5 1315660 [A/G] rs6554759 5 1317102 [A/G] rs1801075 5 1317949 [T/C] NM_030782 CLPTM1L EXON Silent rs380286 5 1320247 [A/G] NM_030782 CLPTM1L Silent rs402710 5 1320722 [T/C] NM_030782 CLPTM1L Silent rs10073340 5 1321873 [T/C] NM_030782 CLPTM1L Silent rs31489 5 1342714 [A/C] NM_030782 CLPTM1L Silent rs31490 5 1344458 [A/G] NM_030782 CLPTM1L Silent rs37006 5 1355058 [T/C] rs27061 5 1362793 [T/C] rs461193 5 1368997 [A/G] NR_125810 LINC01511 Silent rs10075239 5 1370300 [T/G] NR_125810 LINC01511 Silent rs2963265 5 1370832 [T/C] NR_125810 LINC01511 Silent rs246994 5 1376161 [A/G] NR_125810 LINC01511 Silent rs2963259 5 1377172 [A/G] NR_125810 LINC01511 Silent rs2963257 5 1378159 [T/C] NR_125810 LINC01511 Silent rs37017 5 1379762 [T/C] NR_125810 LINC01511 EXON Silent rs12516758 5 1390349 [T/C] rs10064525 5 1392721 [T/G] rs28363172 5 1393494 [T/C] NM_001044 SLC6A3 EXON Silent rs27072 5 1394522 [T/C] NM_001044 SLC6A3 EXON Silent rs1042098 5 1394815 [A/G] NM_001044 SLC6A3 EXON Silent rs40184 5 1395077 [T/C] NM_001044 SLC6A3 Silent rs6869645 5 1404548 [T/C] NM_001044 SLC6A3 Silent rs6880875 5 1406375 [T/C] NM_001044 SLC6A3 EXON Synonymous_Q509Q rs3776512 5 1407116 [A/G] NM_001044 SLC6A3 Silent rs2270912 5 1409836 [A/G] NM_001044 SLC6A3 EXON Synonymous_N466N rs27048 5 1412645 [T/C] NM_001044 SLC6A3 Silent rs2042449 5 1416646 [A/G] NM_001044 SLC6A3 Silent rs6348 5 1420801 [A/G] NM_001044 SLC6A3 EXON Synonymous_A270A rs464049 5 1423905 [A/G] NM_001044 SLC6A3 Silent rs11737901 5 1430616 [T/C] NM_001044 SLC6A3 Silent rs460000 5 1432825 [T/G] NM_001044 SLC6A3 Silent rs403636 5 1438354 [A/C] NM_001044 SLC6A3 Silent rs6350 5 1443199 [A/G] NM_001044 SLC6A3 EXON Synonymous_N38N rs3756450 5 1448148 [A/G] rs2937648 5 1457133 [A/G] rs748209 5 1457554 [A/C] rs7737692 5 1461167 [A/G] rs2292023 5 1461389 [A/C] rs9728 5 1462098 [A/G] NM_024830 LPCAT1 EXON Silent rs4975648 5 1468287 [A/C] NM_024830 LPCAT1 Silent rs2277005 5 1470900 [A/G] NM_024830 LPCAT1 Silent rs27056 5 1473977 [A/G] NM_024830 LPCAT1 Silent rs10043491 5 1476785 [A/C] NM_024830 LPCAT1 Silent rs1010626 5 1490594 [T/C] NM_024830 LPCAT1 Silent rs10058172 5 1491009 [A/G] NM_024830 LPCAT1 Silent rs9800090 5 1492559 [A/G] NM_024830 LPCAT1 Silent rs6554859 5 1493608 [A/G] NM_024830 LPCAT1 Silent rs40180 5 1494439 [T/C] NM_024830 LPCAT1 Silent rs3733796 5 1494909 [T/C] NM_024830 LPCAT1 EXON Synonymous_A133A rs36991 5 1496622 [T/C] NM_024830 LPCAT1 Silent rs36990 5 1497626 [T/C] NM_024830 LPCAT1 Silent rs36988 5 1498986 [A/G] NM_024830 LPCAT1 Silent rs7715002 5 1499057 [T/C] NM_024830 LPCAT1 Silent rs36987 5 1499175 [T/C] NM_024830 LPCAT1 Silent rs10058381 5 1500160 [T/C] NM_024830 LPCAT1 Silent rs17588991 5 1501695 [A/G] NM_024830 LPCAT1 EXON Synonymous_L53L rs36982 5 1503205 [T/C] NM_024830 LPCAT1 Silent rs36979 5 1503610 [T/C] NM_024830 LPCAT1 Silent rs36971 5 1506303 [A/G] NM_024830 LPCAT1 Silent rs36966 5 1508270 [T/C] NM_024830 LPCAT1 Silent rs2962043 5 1508837 [T/C] NM_024830 LPCAT1 Silent rs13160153 5 1517198 [T/C] NM_024830 LPCAT1 Silent rs2963279 5 1517322 [T/G] NM_024830 LPCAT1 Silent rs4371798 5 1517642 [A/G] NM_024830 LPCAT1 Silent rs2962061 5 1517881 [T/C] NM_024830 LPCAT1 Silent rs4406174 5 1519079 [T/C] NM_024830 LPCAT1 Silent rs2963275 5 1519693 [A/G] NM_024830 LPCAT1 Silent rs7716426 5 1521573 [T/C] NM_024830 LPCAT1 Silent rs2962057 5 1526098 [T/C] rs9312877 5 1529358 [T/G] rs7712396 5 1529401 [A/C] rs4551123 5 1536257 [A/G] rs2962074 5 1548764 [T/C] rs2962073 5 1548867 [A/G] rs6865199 5 1549771 [T/C] rs2963285 5 1550734 [A/G] rs10079102 5 1550942 [T/C] rs2962066 5 1552714 [T/C] rs2963271 5 1553239 [T/C] rs2963266 5 1555825 [A/C] rs17596501 5 1557372 [A/G] rs4975554 5 1557636 [T/C] rs16880246 5 1558048 [T/C] rs6870653 5 1558628 [T/C] rs4292484 5 1564675 [T/G] rs4975556 5 1565371 [T/C] rs6897307 5 1568442 [T/C] rs13188808 5 1568508 [T/C] rs4415117 5 1594995 [A/C] rs11958097 5 1612612 [A/C] NR_003713 LOC728613 Silent rs1968011 5 1624351 [T/C] NR_003713 LOC728613 Silent rs6554915 5 1639901 [T/C] rs6888166 5 1641815 [T/C] rs7705049 5 1644315 [A/C] rs7705207 5 1644394 [T/C] rs4551124 5 1645242 [T/C] rs6866927 5 1650262 [A/G] rs10079749 5 1656054 [T/C] rs1106136 5 1659414 [A/C] rs2133740 5 1660985 [A/G] rs904734 5 1661397 [T/C] rs6880499 5 1670369 [A/G] rs931709 5 1671200 [T/C] rs10056116 5 1676638 [A/G] rs6897438 5 1676963 [A/G] rs7703975 5 1679750 [T/C] rs10075284 5 1683758 [T/C] rs16883078 5 1685297 [T/C] rs10512656 5 1685594 [A/G] rs17597967 5 1685655 [A/G] rs6898158 5 1686233 [T/C] rs12108744 5 1686960 [T/C] rs13171033 5 1687735 [T/C] rs10051939 5 1687769 [T/C] rs1875197 5 1691268 [A/G] rs9312928 5 1693575 [T/G] rs10071895 5 1694562 [A/G] rs6864519 5 1698123 [A/G] rs12519991 5 1699151 [A/G] rs2883367 5 1705102 [A/G] rs16883496 5 1705513 [A/C] rs12523324 5 1708983 [A/G] NR_036240 MIR4277 EXON Silent rs904728 5 1719213 [T/C] rs872015 5 1720276 [A/G] rs2133738 5 1721003 [A/G] rs2354124 5 1721485 [T/C] rs16883799 5 1721527 [A/G] rs12515850 5 1723063 [A/G] rs11133883 5 1723309 [T/C] rs16883827 5 1723360 [T/G] rs7730084 5 1725206 [T/C] rs7718539 5 1730637 [T/C] rs6554987 5 1739266 [T/C] rs1392466 5 1744484 [A/G] rs1392469 5 1744831 [A/G] rs2242411 5 1753306 [T/C] rs11741606 5 1759000 [A/G] rs16884541 5 1760815 [A/C] rs11750191 5 1761033 [T/C] rs16884543 5 1761089 [A/G] rs1107059 5 1764128 [T/C] rs1107060 5 1764532 [T/C] rs2353591 5 1764750 [A/G] rs7726044 5 1766736 [T/G] rs6884150 5 1767774 [A/G] rs6555008 5 1769749 [T/C] rs13154034 5 1770225 [T/G] rs5000660 5 1771032 [T/C] rs2172532 5 1772615 [A/G] rs924461 5 1776573 [T/C] rs750532 5 1777840 [T/C] rs13186705 5 1778342 [A/C] rs11953809 5 1778464 [T/C] rs11957879 5 1778473 [T/C] rs10040940 5 1779843 [T/C] rs13171074 5 1782838 [T/C] rs10866525 5 1783237 [T/C] rs12514619 5 1783655 [T/C] rs13186183 5 1791180 [T/C] rs4975846 5 1794921 [T/C] rs1546253 5 1796564 [T/C] rs7703762 5 1797548 [T/C] rs2276986 5 1797735 [A/G] rs972890 5 1800436 [A/C] rs3776150 5 1803901 [T/C] NM_004553 NDUFS6 Silent rs17535721 5 1806653 [A/G] NM_004553 NDUFS6 Silent rs10058270 5 1815950 [T/C] NM_004553 NDUFS6 Silent rs4147775 5 1816431 [G/C] rs4975853 5 1818127 [T/C] rs6864000 5 1820557 [A/G] rs4975854 5 1822326 [T/C] rs7707397 5 1829481 [A/G] rs6555013 5 1833627 [T/C] rs2172530 5 1835083 [A/G] rs17608534 5 1837644 [T/C] rs10061246 5 1838826 [A/G] rs6555016 5 1839458 [T/C] rs10512646 5 1839498 [A/G] rs16901305 5 1844498 [T/C] rs12188301 5 1847639 [A/G] rs10512645 5 1850220 [A/G] rs10512644 5 1850563 [T/G] rs263213 5 1852284 [T/G] rs260397 5 1854257 [T/C] rs91315 5 1855301 [T/C] rs260393 5 1856596 [T/C] NR_104602 LINC02116 EXON Silent rs1532272 5 1859721 [T/C] rs4975744 5 1860049 [A/G] rs1689746 5 1860281 [T/C] rs2353580 5 1871880 [A/G] rs883823 5 1872329 [T/C] rs1632597 5 1875037 [T/C] rs4975709 5 1877280 [A/C] rs4975753 5 1880865 [T/C] NM_016358,NM_001278633,NM_001278634,NM_001278632,NM_001278635 IRX4,IRX4,IRX4,IRX4,IRX4 EXON Synonymous_P127P,Synonymous_P127P,Synonymous_P127P,Synonymous_P127P,Synonymous_P127P rs2232376 5 1880891 [T/C] NM_016358,NM_001278633,NM_001278634,NM_001278632,NM_001278635 IRX4,IRX4,IRX4,IRX4,IRX4 EXON Missense_A119T,Missense_A119T,Missense_A119T,Missense_A119T,Missense_A119T rs260402 5 1881733 [T/C] NM_016358,NM_001278633,NM_001278634,NM_001278632,NM_001278635 IRX4,IRX4,IRX4,IRX4,IRX4 Silent,Silent,Silent,Silent,Silent rs260400 5 1886471 [A/G] NM_001278633,NM_001278634,NM_001278632,NM_001278635 IRX4,IRX4,IRX4,IRX4 Silent,Silent,Silent,Silent rs260409 5 1887817 [T/C] NR_109912 CTD-2194D22.4 Silent rs6861778 5 1892759 [T/G] NR_109912 CTD-2194D22.4 Silent rs12653946 5 1895829 [T/C] NR_109912 CTD-2194D22.4 Silent rs6861105 5 1897640 [T/C] NR_109912 CTD-2194D22.4 Silent rs10428597 5 1898679 [A/C] NR_109912 CTD-2194D22.4 Silent rs17537048 5 1901205 [A/G] rs11749971 5 1906798 [A/C] rs6894487 5 1909022 [T/C] rs4975760 5 1911035 [T/C] rs4975713 5 1911819 [A/G] rs1994388 5 1912921 [T/C] rs2353009 5 1917151 [T/C] rs6555019 5 1917761 [T/C] rs6420033 5 1922870 [T/G] rs10042507 5 1927293 [T/C] rs6555027 5 1927412 [A/G] rs10058874 5 1932463 [A/G] rs6893465 5 1934490 [A/G] rs4975714 5 1934666 [A/G] rs10065645 5 1936116 [A/G] rs11737953 5 1937407 [T/C] rs901495 5 1938626 [A/G] rs6892417 5 1939938 [A/G] rs11743544 5 1943728 [T/C] rs10079709 5 1944308 [A/G] rs11133917 5 1947034 [A/G] rs13183501 5 1948303 [T/C] rs1471886 5 1948464 [T/C] rs11746674 5 1948519 [A/G] rs972973 5 1949340 [T/C] rs7736642 5 1949562 [T/C] rs10074172 5 1949753 [T/C] rs10055976 5 1953161 [A/G] rs13170991 5 1956884 [A/G] rs4246751 5 1956973 [A/C] rs2200559 5 1957109 [T/C] rs12654104 5 1962256 [T/C] rs12654102 5 1962436 [A/G] rs12656386 5 1965996 [T/C] rs2353003 5 1966873 [A/G] rs1017923 5 1967265 [A/G] rs1023981 5 1967849 [A/C] rs4975777 5 1973324 [T/G] rs1017924 5 1976187 [A/G] rs1123391 5 1976478 [T/C] rs13172746 5 1983710 [T/C] rs1601641 5 1987633 [A/G] rs13153232 5 1992423 [A/G] rs6860447 5 1993053 [A/G] rs17611544 5 1993900 [A/G] rs1872775 5 1999840 [T/C] rs13189295 5 2001045 [A/G] rs4493711 5 2001784 [A/G] rs10068684 5 2002126 [T/C] rs11749073 5 2003180 [A/G] rs10474733 5 2004160 [A/G] rs901508 5 2007007 [T/C] rs901498 5 2008571 [A/G] rs7717285 5 2008973 [T/C] rs4975792 5 2010496 [T/G] rs4975721 5 2011360 [A/G] rs13190594 5 2012474 [T/C] rs9312971 5 2012888 [A/C] rs2220309 5 2014366 [A/G] rs4246753 5 2014721 [A/G] rs4246754 5 2014776 [A/C] rs17612453 5 2016422 [T/C] rs10076342 5 2018426 [T/C] rs6555044 5 2029236 [T/G] rs4975807 5 2032660 [T/C] rs4129455 5 2041665 [A/G] rs4975840 5 2047463 [A/G] rs10065111 5 2050328 [T/G] rs4975838 5 2050483 [T/C] rs10055267 5 2053188 [T/C] rs6555046 5 2056586 [A/G] rs4975727 5 2058143 [A/G] rs13163790 5 2058183 [T/C] rs7719270 5 2059311 [A/G] rs4975833 5 2064969 [T/C] rs10475133 5 2075104 [A/G] rs10475134 5 2075162 [T/G] rs4361562 5 2075565 [A/G] rs11133927 5 2077356 [T/G] rs7704452 5 2077642 [A/G] rs9686356 5 2082477 [T/C] rs4566837 5 2083797 [A/G] rs11743496 5 2086448 [A/C] rs10063808 5 2087916 [T/G] rs7702195 5 2089221 [T/C] rs10060649 5 2090652 [T/C] rs11748879 5 2091155 [A/G] rs10076573 5 2094148 [T/C] rs4568402 5 2097011 [A/G] rs13360716 5 2097819 [T/C] rs13180333 5 2099667 [A/G] rs4975819 5 2103617 [T/C] rs10051274 5 2105709 [T/C] rs6879627 5 2109901 [T/C] rs11950809 5 2113672 [A/C] rs6861474 5 2117328 [A/G] rs7446517 5 2117795 [T/C] rs4075798 5 2123985 [A/G] rs4077288 5 2129233 [A/G] rs7445923 5 2129738 [T/G] rs11953155 5 2131784 [T/C] rs6860349 5 2133412 [A/G] rs7736696 5 2135268 [T/C] rs6555064 5 2136570 [T/C] rs7719723 5 2137758 [T/G] rs11960538 5 2140755 [T/C] rs7378721 5 2141588 [T/C] rs6893579 5 2144662 [A/G] rs7448302 5 2149503 [T/C] rs7735656 5 2150273 [T/G] rs6872691 5 2156561 [A/G] rs17644704 5 2156619 [A/C] rs11133930 5 2158553 [T/C] rs10057699 5 2159310 [T/C] rs10072352 5 2159490 [A/G] rs4866721 5 2163977 [T/C] rs10076206 5 2164702 [A/G] rs10076280 5 2164846 [A/G] rs13171126 5 2166397 [T/C] rs6863477 5 2166433 [T/C] rs10043392 5 2166776 [T/C] rs4591752 5 2167740 [A/G] rs11746413 5 2170286 [T/C] rs17645173 5 2173676 [T/C] rs6878643 5 2174313 [T/C] rs4866475 5 2174621 [A/G] rs6555068 5 2175401 [A/G] rs4262114 5 2175605 [T/C] rs16903521 5 2175760 [T/C] rs12658255 5 2178060 [A/C] rs10073915 5 2178140 [T/C] rs10057158 5 2179628 [T/C] rs6555069 5 2182854 [T/C] rs13172851 5 2184365 [T/C] rs11133935 5 2191437 [T/C] rs4866654 5 2194596 [A/G] rs16903612 5 2194769 [A/C] rs16903629 5 2196941 [T/C] rs2405802 5 2199605 [A/C] rs6865374 5 2200150 [A/G] rs12187097 5 2202172 [A/G] rs1542430 5 2202971 [T/C] rs6555073 5 2204833 [T/C] rs10060730 5 2207155 [A/G] rs11133937 5 2208339 [T/C] rs10041522 5 2214721 [T/G] rs10058811 5 2215243 [A/C] rs4263504 5 2216296 [T/C] rs11741203 5 2218025 [A/G] rs10512689 5 2223959 [T/C] rs1458521 5 2229014 [T/C] rs1458516 5 2247093 [T/C] rs6878043 5 2251109 [A/C] rs6882404 5 2251313 [A/G] rs2018533 5 2251369 [A/G] rs2020430 5 2251386 [A/G] rs10061160 5 2252304 [A/G] rs10068115 5 2252398 [A/G] rs1458514 5 2254124 [A/G] rs1458513 5 2254295 [T/C] rs10475140 5 2256873 [A/G] rs2004010 5 2259217 [T/C] rs6871126 5 2265478 [T/C] rs6877636 5 2266931 [A/C] rs593929 5 2268735 [T/C] rs9765121 5 2269218 [A/C] rs6875273 5 2272248 [A/G] rs7732508 5 2275109 [T/C] rs464904 5 2275627 [T/C] rs575414 5 2279208 [T/C] rs2609085 5 2279457 [T/C] rs2405570 5 2279678 [A/G] rs1870335 5 2279813 [A/C] rs923048 5 2279866 [A/G] rs547706 5 2280105 [A/G] rs635969 5 2282348 [T/C] rs554745 5 2286042 [A/G] rs2652148 5 2286126 [A/G] rs316575 5 2286906 [T/C] rs4866449 5 2287730 [A/C] rs6897849 5 2289420 [A/G] rs2652147 5 2291316 [A/G] rs316578 5 2294533 [A/G] rs13187359 5 2295317 [T/C] rs882496 5 2301089 [A/G] rs882497 5 2301342 [T/C] rs922025 5 2302513 [A/G] rs316574 5 2304811 [T/G] NR_104616 LOC100506858 Silent rs316573 5 2305235 [T/C] NR_104616 LOC100506858 Silent rs7718226 5 2305490 [A/G] NR_104616 LOC100506858 Silent rs316566 5 2308239 [T/G] NR_104616 LOC100506858 Silent rs457602 5 2311343 [A/G] NR_104616 LOC100506858 Silent rs316582 5 2315086 [A/G] rs7445525 5 2317424 [A/G] rs12189181 5 2319964 [A/C] rs1032112 5 2320472 [A/G] rs160726 5 2322360 [T/C] rs320597 5 2323282 [T/C] rs458382 5 2329018 [T/C] rs458131 5 2329410 [T/G] rs898060 5 2330992 [T/C] rs16867991 5 2333103 [A/G] rs467939 5 2333303 [A/G] rs2641217 5 2333982 [T/C] rs1873952 5 2335228 [T/C] rs1873951 5 2335313 [A/C] rs13169221 5 2337193 [T/C] rs92833 5 2338908 [T/C] rs462498 5 2339273 [A/G] rs468976 5 2346621 [A/G] rs467723 5 2352620 [A/G] rs10036054 5 2352730 [T/C] rs461425 5 2354731 [A/G] rs462906 5 2355389 [T/C] rs458006 5 2355587 [A/C] rs10069375 5 2356789 [A/C] rs7733952 5 2358493 [T/G] rs7709574 5 2358675 [A/G] rs10071443 5 2360079 [A/G] rs10474742 5 2363480 [T/C] rs6869394 5 2366237 [A/G] rs10036992 5 2371873 [A/G] rs7715102 5 2374305 [T/C] rs16899405 5 2376332 [A/G] rs465850 5 2378836 [T/C] rs457979 5 2382270 [A/G] rs462203 5 2383722 [T/C] rs931283 5 2387550 [T/C] rs6895737 5 2389029 [T/C] rs160730 5 2392831 [A/G] rs6871313 5 2397617 [A/G] rs468085 5 2399225 [A/G] rs518850 5 2400064 [T/C] rs624376 5 2400149 [T/C] rs464716 5 2400280 [T/C] rs10059366 5 2403444 [A/G] rs4866482 5 2409988 [T/C] rs17648791 5 2417417 [A/G] rs4866484 5 2418025 [A/G] rs315914 5 2418088 [A/G] rs10462757 5 2420984 [A/G] rs16869257 5 2420992 [T/G] rs13358358 5 2424387 [T/C] rs6875672 5 2447447 [T/C] rs438055 5 2448052 [A/G] rs370672 5 2448146 [A/G] rs6555108 5 2448160 [A/G] rs16869638 5 2448538 [A/G] rs4866650 5 2448590 [A/C] rs1908159 5 2453377 [A/G] rs315893 5 2458254 [T/G] rs11746384 5 2462271 [A/G] rs6877519 5 2463858 [A/G] rs412137 5 2465418 [A/G] rs10069090 5 2466186 [A/C] rs315918 5 2466584 [T/C] rs10070890 5 2466797 [T/C] rs924134 5 2468375 [A/C] rs9312995 5 2470082 [T/C] rs1496447 5 2471705 [A/G] rs3104228 5 2474274 [T/C] rs10075636 5 2479446 [T/C] rs1992827 5 2488341 [T/C] rs459685 5 2491809 [T/C] rs2453814 5 2493280 [A/C] rs895658 5 2494273 [T/C] rs10475158 5 2495251 [A/G] rs1493650 5 2498479 [A/G] rs3112415 5 2505743 [T/C] rs16869844 5 2509474 [T/C] rs10039326 5 2513346 [A/G] rs13354963 5 2513613 [T/C] rs10462760 5 2514880 [T/C] rs3112411 5 2514931 [A/C] rs3112409 5 2516230 [T/C] rs17651154 5 2516620 [A/G] rs3112408 5 2516934 [A/G] rs378257 5 2518738 [T/C] rs7720355 5 2518949 [T/C] rs385263 5 2519149 [T/C] rs6897037 5 2521534 [T/C] rs13171172 5 2522181 [A/G] rs16869867 5 2522212 [T/C] rs374683 5 2522431 [T/C] rs419628 5 2523602 [T/C] rs17598228 5 2530794 [A/G] rs6875477 5 2533617 [A/G] rs6888076 5 2537894 [T/C] rs12517190 5 2538080 [T/C] rs16869906 5 2539161 [A/G] rs6879053 5 2539286 [A/G] rs323689 5 2543192 [T/C] rs13436812 5 2544880 [A/C] rs7722184 5 2552268 [A/G] rs6888228 5 2553159 [T/C] rs323691 5 2557781 [A/G] rs323695 5 2563109 [A/G] rs16869997 5 2563748 [T/C] rs323698 5 2564145 [T/C] rs323700 5 2564243 [T/C] rs452695 5 2564919 [A/G] rs445296 5 2565830 [T/G] rs437485 5 2569156 [T/C] rs323707 5 2571422 [A/G] rs1159055 5 2572654 [A/G] rs404016 5 2575174 [T/C] rs380259 5 2575392 [T/C] rs9647565 5 2576250 [T/C] rs10866539 5 2577035 [A/G] rs16870061 5 2578112 [T/C] rs403500 5 2578373 [A/G] rs6555116 5 2579350 [A/G] rs376205 5 2582828 [T/C] rs7705916 5 2586224 [T/C] rs225752 5 2588264 [T/C] rs7726088 5 2588400 [A/C] rs569244 5 2599639 [T/C] rs390560 5 2601689 [A/G] rs323685 5 2604686 [T/C] rs10512678 5 2604903 [T/C] rs6877761 5 2605834 [T/C] rs2962561 5 2605988 [T/C] rs392985 5 2609350 [A/G] rs395063 5 2610337 [T/C] rs434930 5 2610744 [A/G] rs10512677 5 2611996 [A/G] rs2004187 5 2612747 [A/C] rs2937764 5 2614896 [A/G] rs11742219 5 2617235 [T/C] rs17659675 5 2617846 [A/G] rs2922062 5 2618844 [A/G] rs13436220 5 2620072 [T/G] rs323651 5 2621228 [T/C] rs1875539 5 2622585 [A/G] rs172834 5 2622918 [A/G] rs6862981 5 2625833 [T/C] rs2441949 5 2627075 [A/C] rs1868038 5 2627545 [A/G] rs406353 5 2627728 [A/G] rs1868037 5 2627745 [A/G] rs437272 5 2627822 [T/C] rs7703939 5 2628328 [A/G] rs323666 5 2630823 [A/G] rs323668 5 2632712 [T/C] rs6555117 5 2635891 [A/G] rs323672 5 2637827 [T/C] rs16870181 5 2638379 [T/C] rs2405037 5 2640007 [T/C] rs13155678 5 2640289 [T/C] rs323653 5 2640466 [A/G] rs323654 5 2640771 [A/C] rs905230 5 2641522 [A/G] rs10053325 5 2641638 [A/G] rs17660394 5 2643974 [T/G] rs323658 5 2645159 [A/C] rs921127 5 2646701 [A/G] rs12186830 5 2647306 [A/G] rs10475171 5 2650624 [A/G] rs6859765 5 2652947 [A/G] rs7705712 5 2653554 [A/G] rs10475173 5 2654417 [T/C] rs7713186 5 2655116 [T/C] rs12518480 5 2655990 [A/G] rs7737578 5 2657449 [T/C] rs16870259 5 2658026 [A/G] rs2897046 5 2663723 [T/C] rs7732655 5 2663888 [T/C] rs2962558 5 2664086 [A/G] rs7356656 5 2664214 [T/C] rs2937761 5 2664245 [A/G] rs6555120 5 2667632 [T/C] rs950864 5 2667858 [T/G] rs7711788 5 2668308 [A/G] rs2937762 5 2670222 [A/G] rs10066976 5 2671057 [T/C] rs10054312 5 2674526 [T/C] rs7721778 5 2676993 [T/G] rs924218 5 2686712 [A/G] rs10071208 5 2690668 [A/G] rs2962610 5 2692076 [A/G] rs11748873 5 2692841 [T/G] rs10079562 5 2694637 [T/G] rs10079610 5 2694684 [A/G] rs4866662 5 2696580 [T/C] rs16870313 5 2696644 [T/C] rs904124 5 2697960 [A/G] rs10066528 5 2700386 [T/C] rs11133959 5 2701674 [T/C] rs2860332 5 2703282 [T/C] rs10474751 5 2706414 [A/C] rs2962587 5 2709971 [A/G] rs6862975 5 2716280 [A/G] rs2962580 5 2716573 [A/G] rs2173226 5 2724362 [T/C] rs1566163 5 2725382 [T/C] rs6866626 5 2726735 [T/C] rs2962571 5 2731785 [T/C] rs1039160 5 2734972 [A/G] rs4866665 5 2737502 [A/C] rs924213 5 2737700 [T/C] rs2962564 5 2740131 [T/C] rs1540709 5 2746229 [A/C] rs11432 5 2747127 [A/G] NM_033267,NM_001134222 IRX2,IRX2 EXON Silent,Silent rs4866667 5 2755932 [T/C] rs1995106 5 2757920 [A/C] rs1353630 5 2757940 [A/C] rs6555128 5 2762286 [A/C] rs2047385 5 2765165 [A/G] rs6867840 5 2767183 [A/G] rs6883371 5 2767357 [T/C] rs2935623 5 2767556 [A/G] rs10071246 5 2768879 [T/C] rs7712012 5 2772332 [T/C] rs13355853 5 2774101 [A/G] rs12522364 5 2775566 [T/C] rs7733720 5 2777178 [A/G] rs7709328 5 2777311 [A/G] rs2068829 5 2778782 [T/C] rs4866498 5 2782587 [T/C] rs2132870 5 2783046 [A/G] rs1024048 5 2783561 [T/C] rs6864829 5 2783869 [T/C] rs6870714 5 2785072 [T/C] rs7702905 5 2788906 [A/G] rs7727905 5 2789155 [T/G] rs6867209 5 2789702 [A/G] rs1908976 5 2789932 [T/C] rs16870453 5 2795776 [T/C] rs11959104 5 2798478 [A/G] rs7729458 5 2799100 [A/C] rs1497457 5 2799759 [A/G] rs16870476 5 2801757 [T/C] rs10512672 5 2802065 [A/C] rs7710715 5 2802282 [A/G] rs10043028 5 2809055 [A/C] rs904117 5 2809713 [A/G] rs4866679 5 2811135 [T/G] rs6878883 5 2812230 [T/G] rs16870505 5 2813509 [T/G] rs4866504 5 2814881 [T/C] rs1122217 5 2815488 [A/G] rs13154311 5 2815854 [T/C] rs1540708 5 2818217 [T/C] rs7714315 5 2818295 [T/C] rs13170951 5 2822959 [A/G] rs10038374 5 2823353 [A/G] rs7701252 5 2828738 [A/G] rs10038356 5 2829191 [A/G] rs1018089 5 2831070 [T/G] rs6862810 5 2831521 [T/C] rs13157801 5 2832643 [A/G] rs13163086 5 2833623 [A/C] rs2047379 5 2834261 [A/G] rs6879558 5 2834281 [T/C] rs13178497 5 2838420 [A/G] rs12054687 5 2841709 [A/G] rs10866544 5 2843679 [T/G] rs7442964 5 2843763 [T/C] rs17626019 5 2844917 [T/C] rs13160629 5 2845113 [T/C] rs438418 5 2849436 [A/G] rs559379 5 2851856 [A/G] rs12655083 5 2852127 [A/G] rs903246 5 2853858 [T/C] rs1004953 5 2857885 [T/C] rs1004952 5 2858054 [A/G] rs2974638 5 2858513 [T/C] rs10055154 5 2860537 [A/C] rs16870583 5 2861216 [T/C] rs6884970 5 2865272 [T/C] rs6881327 5 2865604 [A/G] rs9313014 5 2866246 [A/G] rs9313015 5 2866346 [T/G] rs1024029 5 2869505 [T/C] rs6899275 5 2870681 [T/C] rs756220 5 2878297 [A/G] rs2934550 5 2878637 [A/G] rs16870625 5 2883677 [A/G] rs4866693 5 2884879 [T/G] rs4866694 5 2886593 [T/C] rs12520786 5 2891419 [A/G] rs12654325 5 2892699 [T/C] rs6555146 5 2893943 [A/G] rs13153727 5 2896161 [T/G] rs11745728 5 2897087 [T/C] rs16874895 5 2897116 [T/C] rs7731319 5 2897236 [T/C] rs7732075 5 2900123 [A/G] rs2974657 5 2901649 [A/C] rs1389595 5 2902855 [T/C] rs2860294 5 2902999 [A/G] rs956897 5 2907012 [A/G] rs1565808 5 2908616 [A/G] rs17673214 5 2908851 [A/G] rs2934555 5 2910083 [A/G] rs17627501 5 2912375 [T/C] rs17678795 5 2913619 [T/G] rs903244 5 2915301 [A/C] rs2974690 5 2917143 [T/C] rs2974693 5 2920692 [T/C] rs10061701 5 2922114 [A/G] rs13185688 5 2922427 [A/G] rs1494064 5 2923396 [A/G] rs16874371 5 2923441 [T/C] rs11738897 5 2929499 [T/C] rs10475186 5 2929714 [A/G] rs2404802 5 2934319 [A/C] rs2934519 5 2940406 [T/G] rs1389585 5 2945834 [T/C] rs2934528 5 2947877 [T/G] rs1389589 5 2948632 [T/C] rs7737453 5 2949174 [T/C] rs11133966 5 2950010 [A/G] rs6555155 5 2950492 [A/G] rs2974664 5 2953317 [T/C] rs6893622 5 2955932 [A/G] rs11133968 5 2957068 [A/G] rs2974658 5 2960267 [T/G] rs1565807 5 2965167 [A/G] rs10512669 5 2965303 [T/G] rs10072840 5 2967695 [A/G] rs7724104 5 2968466 [A/G] rs1494066 5 2970320 [A/G] rs13362004 5 2972677 [T/G] rs10454923 5 2972851 [T/G] rs7712980 5 2973458 [A/G] rs12657444 5 2973712 [A/C] rs1494063 5 2974992 [T/C] rs10079415 5 2978271 [T/C] rs4242095 5 2979710 [A/G] rs6888766 5 2981865 [A/G] rs6861422 5 2984081 [A/C] rs6891001 5 2984374 [T/G] rs10070337 5 2993617 [T/C] rs10075407 5 2993645 [A/G] rs6871461 5 2999174 [T/G] rs7712222 5 2999518 [A/C] rs10072629 5 3001216 [A/C] rs2009378 5 3004584 [T/G] rs2009370 5 3004742 [T/C] rs2961797 5 3007514 [T/G] rs2961793 5 3010613 [T/C] rs2922992 5 3011663 [T/C] rs2961782 5 3016244 [T/G] rs10057618 5 3017208 [T/C] rs11952070 5 3017791 [A/G] rs2084547 5 3018524 [T/C] rs12517482 5 3019005 [A/G] rs2404567 5 3025452 [A/G] rs11133974 5 3028654 [T/C] rs10454925 5 3029927 [T/C] rs4866516 5 3032625 [T/C] rs191168 5 3036596 [T/C] rs11133976 5 3042790 [A/G] rs1037291 5 3044895 [T/C] rs10068728 5 3045983 [T/G] rs16870972 5 3054500 [T/C] rs6890167 5 3055887 [A/G] rs170225 5 3059961 [A/G] rs167528 5 3060017 [T/C] rs7706611 5 3060489 [A/G] rs6555171 5 3060697 [A/C] rs160874 5 3061140 [T/C] rs160884 5 3064150 [A/G] rs7728601 5 3064862 [A/G] rs160882 5 3065101 [T/G] rs13154954 5 3066713 [T/C] rs6891263 5 3073199 [T/C] rs466896 5 3073671 [A/G] rs461578 5 3074339 [T/G] rs464050 5 3074414 [T/C] rs10475190 5 3076720 [A/G] rs10475191 5 3076956 [T/G] rs462624 5 3078217 [T/C] rs464918 5 3079057 [T/C] rs16871030 5 3079891 [A/G] rs13172975 5 3080654 [T/C] rs3104064 5 3080880 [T/C] rs9313029 5 3081376 [T/C] rs2016714 5 3082219 [T/C] rs160876 5 3082643 [T/C] rs13188008 5 3083653 [T/G] rs6879233 5 3084205 [A/G] rs11133978 5 3086514 [A/G] rs11957015 5 3086934 [T/C] rs2442700 5 3088781 [T/C] rs11744932 5 3089964 [T/C] rs9313033 5 3090084 [T/G] rs17543060 5 3091466 [T/C] rs6873793 5 3092192 [T/C] rs6872625 5 3092254 [T/G] rs11750911 5 3092510 [A/G] rs4866523 5 3093075 [T/C] rs6870469 5 3094738 [A/G] rs12109259 5 3095124 [A/G] rs11960253 5 3095424 [A/C] rs13187652 5 3095939 [T/C] rs2442697 5 3096001 [A/G] rs314009 5 3098010 [T/G] rs314008 5 3098333 [A/G] rs160888 5 3100475 [T/G] rs317000 5 3103070 [T/C] rs316998 5 3104201 [A/G] rs172700 5 3104267 [T/C] rs4866716 5 3105242 [A/C] rs314002 5 3106162 [T/G] rs160577 5 3107008 [A/G] rs171658 5 3107310 [T/G] rs160770 5 3107861 [T/G] rs17544008 5 3108117 [T/C] rs17621396 5 3109410 [A/C] rs160765 5 3110197 [A/G] rs160761 5 3115056 [T/G] rs160570 5 3115715 [A/G] rs1389879 5 3118894 [T/C] rs6872141 5 3119603 [A/G] rs160780 5 3119937 [T/C] rs160776 5 3121671 [T/C] rs16871117 5 3121728 [T/C] rs160774 5 3121797 [A/G] rs12657742 5 3123775 [A/G] rs6886617 5 3124651 [T/G] rs11748308 5 3124796 [A/C] rs465705 5 3126445 [A/G] rs314011 5 3128216 [T/C] rs1215405 5 3128336 [A/C] rs10043332 5 3128346 [T/C] rs10045318 5 3128522 [A/G] rs16871149 5 3128854 [T/C] rs467544 5 3130281 [A/G] rs469036 5 3130867 [T/G] rs903397 5 3131064 [A/G] rs17551811 5 3131074 [T/C] rs469280 5 3131474 [A/G] rs467716 5 3132025 [T/C] rs160897 5 3132160 [A/G] rs17622688 5 3132458 [A/G] rs469508 5 3132559 [T/C] rs469402 5 3132692 [A/G] rs468334 5 3133471 [T/C] rs160891 5 3134466 [A/G] rs7726783 5 3134719 [A/G] rs160890 5 3134879 [T/C] rs167587 5 3138553 [A/G] rs316996 5 3138651 [A/C] rs597099 5 3139158 [T/C] rs467326 5 3140979 [T/C] rs160906 5 3141651 [A/G] rs828416 5 3142898 [T/C] rs160903 5 3143209 [T/C] rs1215429 5 3145337 [T/G] rs181860 5 3146907 [T/C] rs1661119 5 3150973 [T/C] rs10069129 5 3151352 [T/C] rs1215412 5 3151918 [T/C] rs468828 5 3152858 [T/C] rs457099 5 3156312 [A/G] rs461401 5 3156508 [T/C] rs251817 5 3160085 [T/C] rs9313034 5 3161355 [T/C] rs1691026 5 3162157 [A/G] rs1661106 5 3162549 [A/G] rs1661102 5 3163438 [T/C] rs2172766 5 3163688 [A/C] rs1494681 5 3166087 [T/C] rs9313036 5 3170573 [T/C] rs1215656 5 3170720 [T/G] rs6892918 5 3170959 [T/C] rs2165515 5 3174032 [A/C] rs12657403 5 3174785 [A/G] rs6861203 5 3175819 [A/G] rs16871346 5 3177302 [T/C] rs251833 5 3177876 [A/G] rs1151905 5 3178147 [T/C] NR_104617 LINC01377 EXON Silent rs369283 5 3179620 [T/C] NR_104617 LINC01377 Silent rs1215665 5 3181008 [T/C] NR_104617 LINC01377 Silent rs1151903 5 3183871 [A/G] rs251830 5 3187567 [A/G] rs392439 5 3190290 [A/G] rs431905 5 3192848 [A/G] rs427727 5 3193401 [A/G] rs17555553 5 3194690 [A/C] rs1215693 5 3197490 [A/G] rs875852 5 3200876 [A/G] rs875853 5 3200928 [A/G] rs401195 5 3201049 [A/G] rs13171621 5 3202136 [A/G] rs433274 5 3203444 [T/C] rs10474761 5 3204386 [A/C] rs1310088 5 3205018 [T/C] rs639617 5 3205290 [T/C] rs396670 5 3205765 [T/C] rs1215666 5 3209477 [T/C] rs1215667 5 3209668 [T/C] rs1661066 5 3210098 [T/C] rs396319 5 3211052 [A/G] rs421093 5 3211391 [T/C] rs13360002 5 3212794 [T/C] rs443673 5 3212963 [T/G] rs6894463 5 3213546 [A/G] rs1661071 5 3214704 [A/G] rs1691086 5 3215231 [A/G] rs6555181 5 3215661 [A/C] rs392679 5 3217841 [T/C] rs1632064 5 3219694 [T/C] rs4866534 5 3225962 [T/C] rs4866437 5 3226096 [A/G] rs407190 5 3226865 [A/G] rs6876947 5 3228264 [T/C] rs4866535 5 3231351 [T/C] rs251810 5 3232706 [T/G] rs173726 5 3234220 [T/G] rs415144 5 3237433 [A/G] rs7717593 5 3238376 [A/G] rs6878021 5 3238584 [A/G] rs441638 5 3238615 [A/G] rs7444147 5 3243988 [T/C] rs1691018 5 3244550 [A/G] rs427867 5 3245702 [A/G] rs611396 5 3245982 [T/C] rs1691016 5 3246919 [T/G] rs1691101 5 3250572 [T/C] rs1494678 5 3253177 [A/G] rs1441540 5 3253428 [T/C] rs903405 5 3254137 [T/C] rs16871518 5 3254413 [T/C] rs13436726 5 3255137 [A/G] rs16871519 5 3258039 [T/C] rs6893167 5 3258871 [A/C] rs1441537 5 3261155 [T/C] rs6895234 5 3261996 [T/G] rs1441534 5 3265689 [T/C] rs1441533 5 3265846 [A/G] rs10038264 5 3266396 [T/C] rs7706315 5 3269778 [A/G] rs16871560 5 3269938 [T/C] rs10063962 5 3271982 [T/G] rs17571538 5 3272039 [A/G] rs4866539 5 3273318 [T/C] rs10041745 5 3281517 [T/C] rs4866542 5 3282671 [T/C] rs4546389 5 3285526 [T/C] rs4866544 5 3286292 [T/C] rs4242087 5 3286564 [T/C] rs4866546 5 3286623 [T/C] rs4866547 5 3286715 [T/C] rs4476727 5 3287958 [A/G] rs6893182 5 3288988 [T/C] rs10045706 5 3292902 [A/G] rs4505956 5 3302781 [T/C] rs4866550 5 3308312 [T/C] rs7716659 5 3310539 [A/C] rs11745750 5 3311493 [T/C] rs10866553 5 3313928 [T/C] rs12521832 5 3314923 [T/C] rs11746449 5 3316959 [T/C] rs6896919 5 3317260 [T/C] rs9313047 5 3318642 [T/C] rs12188329 5 3320132 [A/G] rs7716883 5 3329508 [A/G] rs6861409 5 3331005 [A/G] rs13171721 5 3333684 [T/C] rs7718013 5 3333760 [A/G] rs10037437 5 3336053 [T/C] rs7721657 5 3337194 [T/G] rs7735206 5 3337359 [T/C] rs7711995 5 3337491 [T/C] rs11746659 5 3338013 [T/C] rs10045889 5 3338074 [T/C] rs13360235 5 3338456 [A/C] rs7703994 5 3339142 [T/G] rs6860525 5 3343024 [T/C] rs10475202 5 3347836 [A/G] rs6869583 5 3349583 [T/C] rs4521479 5 3356538 [T/C] rs4602632 5 3357818 [A/G] rs10073886 5 3360109 [T/C] rs4397137 5 3362336 [A/C] rs10050840 5 3364201 [A/G] rs4242090 5 3365033 [A/C] rs4147089 5 3366480 [A/G] rs11741411 5 3366544 [T/C] rs4866559 5 3377309 [A/G] rs16871656 5 3379438 [A/G] rs251433 5 3380046 [A/G] rs6875853 5 3380975 [T/C] rs16871658 5 3382263 [T/G] rs6884756 5 3382336 [A/G] rs426126 5 3383339 [T/C] rs395395 5 3383382 [A/G] rs32689 5 3384836 [T/C] rs32687 5 3386191 [T/C] rs6881435 5 3389796 [T/C] rs924610 5 3393547 [T/C] rs32712 5 3395518 [T/C] rs6869954 5 3397467 [T/G] rs4866443 5 3400160 [A/C] rs402272 5 3411611 [A/C] rs7703631 5 3415311 [T/C] rs6555203 5 3415406 [A/C] rs426915 5 3415833 [T/G] rs376855 5 3421142 [A/G] NR_033898 LINC01019 Silent rs17683976 5 3428925 [T/C] NR_033898 LINC01019 Silent rs11742901 5 3429107 [T/C] NR_033898 LINC01019 Silent rs251444 5 3435141 [T/C] NR_033898 LINC01019 Silent rs7732434 5 3436677 [T/G] NR_033898 LINC01019 Silent rs863794 5 3445667 [A/G] NR_033898 LINC01019 Silent rs436417 5 3449132 [A/G] NR_033898 LINC01019 Silent rs32723 5 3451906 [T/G] NR_033898 LINC01019 Silent rs17633433 5 3452743 [T/C] NR_033898 LINC01019 Silent rs876023 5 3452780 [A/G] NR_033898 LINC01019 Silent rs4866447 5 3454482 [A/G] NR_033898,NR_147000 LINC01019,LINC02162 Silent,Silent rs32736 5 3462896 [T/G] NR_033898 LINC01019 Silent rs16871863 5 3463708 [T/G] NR_033898 LINC01019 Silent rs16871865 5 3464268 [T/C] NR_033898 LINC01019 Silent rs396398 5 3465678 [A/C] NR_033898 LINC01019 Silent rs1847011 5 3466243 [A/G] NR_033898 LINC01019 Silent rs11133987 5 3483595 [A/G] NR_033898 LINC01019 Silent rs10866555 5 3490432 [A/G] NR_033898 LINC01019 Silent rs13161526 5 3497620 [A/G] NR_033898,NR_104618 LINC01019,LINC01017 Silent,Silent rs17686103 5 3502963 [T/C] NR_033898,NR_104618 LINC01019,LINC01017 Silent,Silent rs32717 5 3510624 [T/C] NR_033898 LINC01019 Silent rs7713519 5 3510635 [T/C] NR_033898 LINC01019 Silent rs698147 5 3513485 [A/G] NR_033898 LINC01019 Silent rs39620 5 3515183 [T/C] NR_033898 LINC01019 Silent rs828544 5 3520064 [T/G] NR_033898 LINC01019 Silent rs13176060 5 3522987 [T/C] NR_033898 LINC01019 Silent rs11957094 5 3524832 [A/G] NR_033898 LINC01019 Silent rs710987 5 3525440 [A/G] NR_033898 LINC01019 Silent rs698144 5 3528233 [A/G] NR_033898 LINC01019 Silent rs2115350 5 3533532 [A/C] NR_033898 LINC01019 Silent rs32742 5 3538138 [A/G] rs710973 5 3539652 [T/C] rs4866451 5 3540098 [A/G] rs1697997 5 3542548 [T/C] rs17636496 5 3544272 [A/C] rs10056550 5 3547893 [A/G] rs1664738 5 3556260 [T/C] rs17687915 5 3559242 [T/C] rs1428739 5 3559973 [T/C] rs828311 5 3566024 [T/C] rs828309 5 3566312 [A/G] rs2197506 5 3567686 [T/G] rs2195412 5 3569556 [T/C] rs828302 5 3573395 [A/G] rs4866585 5 3574619 [T/G] rs12517827 5 3575370 [A/G] rs11746591 5 3575637 [A/G] rs10067415 5 3579516 [T/G] rs828316 5 3580400 [A/G] rs10042985 5 3581760 [A/G] rs860439 5 3584368 [A/C] rs2561992 5 3584513 [T/C] rs710998 5 3591916 [T/C] rs2166365 5 3597830 [A/G] NM_024337 IRX1 Silent rs861185 5 3599320 [A/G] NM_024337 IRX1 Silent rs1373997 5 3610658 [T/C] rs13168291 5 3611362 [A/G] rs13173543 5 3612448 [A/G] rs13170992 5 3614352 [T/G] rs6555208 5 3617040 [T/C] rs13361949 5 3617604 [T/C] rs7380187 5 3618765 [T/C] rs10059981 5 3619518 [A/G] rs7722069 5 3623182 [T/C] rs12516914 5 3629141 [T/C] rs16872204 5 3631588 [T/C] rs4866455 5 3636551 [A/G] rs2166362 5 3642021 [T/C] rs11133999 5 3643741 [A/G] rs6870795 5 3651176 [T/C] rs13153692 5 3651390 [T/G] rs4866458 5 3655804 [T/C] rs10065876 5 3657787 [A/G] rs4866593 5 3662174 [A/G] rs4866595 5 3662460 [T/C] rs1502645 5 3663183 [A/G] rs7733481 5 3663741 [A/G] rs10035726 5 3670728 [A/G] rs6883836 5 3670973 [T/C] rs1502644 5 3671006 [A/C] rs16872244 5 3671350 [T/C] rs7711236 5 3675933 [T/G] rs2398622 5 3678658 [A/G] rs6892937 5 3684777 [A/C] rs4866462 5 3687568 [A/C] rs10071484 5 3689527 [T/C] rs13173587 5 3690564 [T/C] rs6866062 5 3692378 [A/G] rs11960785 5 3693627 [T/C] rs4866604 5 3695920 [A/G] rs10042356 5 3698654 [T/C] rs1502641 5 3699935 [T/C] rs13169861 5 3700168 [A/G] rs11134011 5 3702207 [A/G] rs17639575 5 3702694 [A/G] rs1039460 5 3703076 [A/C] rs12055017 5 3703971 [A/G] rs954767 5 3706050 [A/C] rs12659333 5 3707452 [T/C] rs4866607 5 3710450 [A/G] rs10062024 5 3710645 [A/G] rs4866465 5 3711519 [A/G] rs7714769 5 3711914 [A/G] rs2398624 5 3714522 [A/C] rs6878714 5 3715708 [A/G] rs2134400 5 3717009 [A/C] rs7729617 5 3717737 [A/G] rs12522688 5 3717768 [T/C] rs1502635 5 3718000 [T/G] rs1604563 5 3718709 [T/C] rs11749388 5 3724533 [T/G] rs1566691 5 3727179 [A/G] rs10040425 5 3727332 [A/C] rs13174381 5 3728440 [A/G] rs13171764 5 3730312 [T/G] rs16872344 5 3735278 [A/G] rs4866470 5 3742035 [T/C] rs13188410 5 3743335 [A/G] rs7719640 5 3752812 [A/C] rs7730021 5 3754582 [T/C] rs16872388 5 3754860 [T/C] rs13361372 5 3757066 [T/C] rs905350 5 3760907 [T/C] rs11750498 5 3763450 [T/G] rs13436137 5 3765085 [A/G] rs2134404 5 3766628 [A/G] rs11741338 5 3770600 [A/G] rs1039462 5 3771121 [A/G] rs13356024 5 3773462 [A/G] rs13156175 5 3774574 [A/G] rs955635 5 3777302 [T/C] rs6882956 5 3779591 [A/G] rs1566689 5 3781181 [T/C] rs2963803 5 3781191 [A/G] rs10059788 5 3783340 [A/C] rs13177139 5 3783643 [T/C] rs2963801 5 3787719 [T/C] rs2967831 5 3789862 [A/G] rs2963799 5 3790765 [T/G] rs7726033 5 3792631 [A/G] rs10462777 5 3794274 [T/C] rs11948295 5 3800097 [T/C] rs10060475 5 3801906 [A/G] rs12659399 5 3802888 [T/C] rs2967839 5 3805412 [T/C] rs11741748 5 3809622 [A/G] rs2967840 5 3809717 [A/G] rs7729252 5 3815015 [A/G] rs2174047 5 3815297 [T/C] rs2134403 5 3815679 [T/G] rs12657754 5 3822893 [A/G] rs13180945 5 3824532 [T/C] rs12521994 5 3833240 [A/G] rs11750441 5 3834405 [A/G] rs2963794 5 3834603 [T/C] rs2860410 5 3840278 [A/G] rs2932321 5 3840381 [T/C] rs2398647 5 3844414 [A/G] rs2963791 5 3844541 [A/C] rs9687393 5 3845683 [A/G] rs1994579 5 3845917 [T/C] rs2967821 5 3846180 [T/C] rs12153260 5 3856449 [T/C] rs16872456 5 3862889 [A/G] rs17653429 5 3865308 [A/G] rs2895167 5 3865417 [A/G] rs10078577 5 3869785 [A/G] rs1318458 5 3872550 [T/C] rs2932318 5 3872717 [T/C] rs11740041 5 3872831 [A/G] rs583835 5 3873124 [A/G] rs16872476 5 3875103 [A/G] rs478794 5 3879123 [T/G] rs6860576 5 3887013 [T/C] rs623918 5 3888310 [A/G] rs594459 5 3890330 [T/G] rs550167 5 3891796 [T/G] rs10475241 5 3895815 [T/C] rs6886339 5 3904292 [T/C] rs16872548 5 3919288 [T/C] rs11956711 5 3925083 [T/C] rs11958394 5 3926567 [T/C] rs505800 5 3927833 [A/G] rs669675 5 3933631 [A/C] rs511343 5 3943004 [A/G] rs12186559 5 3950622 [T/C] rs10046096 5 3967342 [A/G] rs547398 5 3973783 [A/G] rs1400794 5 3974744 [A/C] rs687595 5 3976564 [A/C] rs4702310 5 3991294 [T/G] rs12187878 5 3992147 [T/C] rs680810 5 3993746 [A/G] rs11748824 5 3997830 [T/C] rs4455563 5 4002470 [A/G] rs10078693 5 4003908 [T/C] rs3943033 5 4012303 [T/C] rs10071096 5 4012694 [A/G] rs540937 5 4014659 [A/G] rs11738089 5 4020601 [A/G] rs6555245 5 4024806 [T/C] rs580641 5 4041154 [A/G] rs16872714 5 4048841 [T/C] rs10040875 5 4050453 [T/C] rs1201368 5 4053766 [A/G] rs11134030 5 4065252 [T/C] rs1187460 5 4071067 [A/G] rs12659815 5 4075178 [A/G] rs2398655 5 4085030 [A/G] rs10462783 5 4088133 [T/C] rs9313067 5 4089547 [A/G] rs9313069 5 4093896 [A/G] rs1187477 5 4096237 [T/C] rs1187478 5 4096258 [T/C] rs1493470 5 4100989 [A/G] rs1187482 5 4101370 [T/C] rs1187483 5 4101569 [T/C] rs1187489 5 4104155 [T/C] rs1187491 5 4105915 [T/G] rs2452883 5 4106399 [T/G] rs10866562 5 4110205 [A/G] rs1911912 5 4123457 [A/C] rs1911914 5 4126106 [A/C] rs1911915 5 4126274 [A/G] rs6873496 5 4135741 [A/G] rs6860112 5 4136154 [T/C] rs17665143 5 4138095 [A/G] rs10063373 5 4140796 [A/C] rs10076711 5 4157570 [A/G] rs10077300 5 4161404 [A/C] rs11134035 5 4175312 [T/C] rs3938039 5 4176833 [A/C] rs11953297 5 4186632 [A/G] rs10051866 5 4193777 [T/C] rs6555259 5 4198117 [A/G] rs6555261 5 4198436 [T/C] rs7734004 5 4205074 [T/G] rs16872928 5 4211418 [T/G] rs7735751 5 4213582 [A/G] rs1035866 5 4216069 [A/G] rs959937 5 4224788 [A/G] rs11948368 5 4225004 [A/G] rs7706780 5 4227497 [T/G] rs12521129 5 4229937 [T/C] rs7723568 5 4230268 [A/C] rs17723577 5 4235808 [A/G] rs17723822 5 4243226 [T/G] rs17723858 5 4244114 [T/C] rs265180 5 4244462 [T/C] rs3105127 5 4248397 [A/G] rs263734 5 4256610 [A/G] rs11739066 5 4257463 [T/G] rs458649 5 4269490 [A/G] rs17543979 5 4269803 [T/C] rs462021 5 4275538 [A/G] rs1532688 5 4280113 [T/C] rs11134042 5 4281622 [A/G] rs255675 5 4281719 [T/C] rs12659526 5 4282851 [T/C] rs12110273 5 4288545 [T/C] rs155349 5 4289170 [A/G] rs11742174 5 4293345 [T/G] rs7702429 5 4293859 [T/C] rs7731506 5 4297423 [A/G] rs1393106 5 4303898 [T/C] rs11134044 5 4305161 [A/G] rs155350 5 4311402 [T/C] rs261133 5 4316307 [T/C] rs11749633 5 4316470 [T/C] rs155279 5 4321335 [T/C] rs155353 5 4325295 [T/C] rs155354 5 4327455 [A/C] rs16873316 5 4336158 [T/C] rs10069119 5 4341114 [A/G] rs155356 5 4346529 [T/C] rs17727202 5 4355708 [T/C] rs261144 5 4356792 [A/G] rs13185799 5 4362756 [T/C] rs261124 5 4368462 [A/G] rs261125 5 4369887 [T/G] rs1354129 5 4372548 [T/C] rs9313075 5 4375021 [T/G] rs261126 5 4375160 [T/C] rs261128 5 4375574 [A/C] rs13175033 5 4375862 [T/C] rs261129 5 4376022 [T/C] rs261130 5 4376717 [A/C] rs12187807 5 4380545 [T/C] rs4701855 5 4380725 [A/C] rs10073943 5 4381727 [A/G] rs10052590 5 4388200 [T/G] rs11948367 5 4389744 [T/C] rs1080648 5 4390768 [A/G] rs12716158 5 4391653 [T/C] rs13168384 5 4396901 [T/G] rs9313076 5 4397173 [T/G] rs9313078 5 4397964 [T/C] rs17677148 5 4399737 [A/G] rs7718259 5 4405918 [A/C] rs4702677 5 4407484 [A/G] rs4701864 5 4409168 [T/C] rs10061612 5 4417155 [A/G] rs12518914 5 4417450 [T/G] rs10044501 5 4419552 [A/G] rs13186177 5 4420716 [T/C] rs10078927 5 4423292 [T/C] rs10076204 5 4426699 [T/C] rs11134052 5 4428580 [A/G] rs10054113 5 4429187 [T/G] rs4286636 5 4436013 [T/C] rs6894740 5 4438356 [A/G] rs10064177 5 4439260 [A/G] rs6861699 5 4439651 [T/C] rs6887047 5 4439786 [T/C] rs6887571 5 4440130 [T/C] rs2043354 5 4442390 [A/C] rs4701877 5 4455368 [T/C] rs17276015 5 4456379 [A/G] rs1433271 5 4456841 [T/C] rs4701884 5 4467380 [T/C] rs9313082 5 4474329 [T/C] rs1433265 5 4474589 [T/C] rs10066908 5 4478547 [A/C] rs10462795 5 4488309 [A/G] rs10036724 5 4491526 [T/C] rs12516470 5 4493944 [T/C] rs16873498 5 4510920 [T/C] rs1450827 5 4511087 [A/C] rs921393 5 4512711 [A/C] rs16873509 5 4514532 [A/G] rs6881826 5 4515447 [T/C] rs921392 5 4515553 [T/C] rs11134055 5 4516670 [T/C] rs13187596 5 4517509 [A/G] rs12517115 5 4520220 [A/C] rs1450822 5 4520856 [A/G] rs17690482 5 4532227 [T/C] rs6555299 5 4534191 [A/G] rs3943533 5 4542749 [A/C] rs10070988 5 4547644 [A/G] rs10064215 5 4547704 [A/G] rs10474781 5 4565002 [A/G] rs12515499 5 4568974 [A/G] rs1030490 5 4574945 [T/G] rs7700360 5 4576516 [A/C] rs2052887 5 4577399 [A/G] rs12657445 5 4577842 [A/G] rs16873639 5 4578875 [T/C] rs10063610 5 4593655 [A/G] rs293067 5 4599400 [T/C] rs7730075 5 4600961 [T/C] rs7710837 5 4601882 [A/G] rs6894400 5 4605931 [T/C] rs16873676 5 4610206 [T/C] rs6887582 5 4629210 [A/G] rs293102 5 4632694 [T/C] rs293105 5 4633275 [A/G] rs10512742 5 4633409 [A/C] rs10512743 5 4633984 [A/G] rs293106 5 4634162 [A/C] rs7713961 5 4638885 [A/G] rs293119 5 4641160 [A/G] rs293123 5 4644270 [A/G] rs11134061 5 4644642 [A/G] rs2077369 5 4645455 [T/C] rs7713507 5 4647436 [T/C] rs6555302 5 4647464 [A/G] rs7713659 5 4647493 [T/C] rs418752 5 4648002 [A/G] rs1428981 5 4648027 [T/C] rs6879780 5 4648932 [T/C] rs16873742 5 4651632 [T/G] rs450409 5 4651742 [A/G] rs1366642 5 4654214 [T/C] rs17692869 5 4654629 [A/C] rs1366643 5 4657375 [T/C] rs1346575 5 4657945 [T/G] rs3928432 5 4659940 [T/C] rs2115525 5 4660902 [A/G] rs7447371 5 4662323 [A/G] rs4702895 5 4663347 [T/C] rs2162995 5 4664704 [T/C] rs11744458 5 4664870 [T/G] rs16873806 5 4665354 [A/G] rs4370242 5 4665670 [A/G] rs2895497 5 4665724 [T/C] rs4407602 5 4668289 [A/G] rs7731649 5 4668593 [T/C] rs7724465 5 4670864 [A/G] rs6555306 5 4671383 [T/C] rs7720816 5 4673835 [T/C] rs4412086 5 4674868 [A/C] rs7716432 5 4675355 [T/C] rs4568336 5 4676429 [T/C] rs13359697 5 4677722 [A/G] rs7713482 5 4678192 [A/G] rs10063789 5 4678221 [A/G] rs7718402 5 4678287 [T/C] rs4235620 5 4679559 [A/G] rs4563594 5 4680691 [T/C] rs11134066 5 4692090 [A/G] rs6885274 5 4695085 [T/G] rs4702913 5 4700587 [A/C] rs12716162 5 4705982 [T/C] rs4532332 5 4706519 [A/G] rs6890255 5 4723324 [T/G] rs6865239 5 4723978 [T/G] rs7711434 5 4724332 [T/C] rs10035433 5 4725405 [T/C] rs17750180 5 4727057 [A/G] rs6895818 5 4730319 [A/G] rs2134180 5 4734171 [T/C] rs1393120 5 4738222 [T/C] rs10056791 5 4739273 [A/G] rs10058793 5 4739819 [T/C] rs7716642 5 4755398 [T/C] rs1501760 5 4761704 [A/G] rs2088900 5 4776191 [T/G] rs4235550 5 4776500 [A/G] rs10069581 5 4777480 [A/G] rs16874044 5 4780629 [T/C] rs1501754 5 4781079 [A/G] rs1173229 5 4784657 [A/G] rs1173228 5 4785389 [A/G] rs1173227 5 4785594 [A/G] rs1173218 5 4788892 [T/C] rs1452040 5 4795354 [A/C] rs10051649 5 4801119 [T/C] rs7728112 5 4801996 [A/C] rs1173179 5 4803549 [T/G] rs1173192 5 4814945 [A/C] rs1173201 5 4819918 [T/C] rs10063051 5 4821758 [T/C] rs10036366 5 4824652 [T/G] rs1173213 5 4825401 [A/G] rs10073827 5 4827086 [T/C] rs11134077 5 4828015 [T/G] rs816475 5 4831601 [T/C] rs2123104 5 4831687 [T/C] rs816480 5 4835205 [A/G] rs10512749 5 4839617 [T/G] rs2652227 5 4840284 [A/C] rs2652221 5 4844322 [A/G] rs860987 5 4853391 [A/G] rs2600642 5 4861432 [A/G] rs707645 5 4867913 [T/C] rs816467 5 4872310 [A/G] rs816468 5 4872511 [A/G] rs16874171 5 4875420 [T/G] rs7728954 5 4884392 [A/G] rs629342 5 4885068 [A/G] rs17752880 5 4885562 [A/G] rs10051514 5 4887171 [A/G] rs590199 5 4900062 [A/C] rs26875 5 4901816 [A/C] rs26880 5 4905892 [T/C] rs6894984 5 4907084 [A/C] rs1392411 5 4907778 [T/C] rs610722 5 4912310 [A/G] rs9885575 5 4912405 [A/G] rs6879578 5 4913228 [A/G] rs6555321 5 4914886 [T/C] rs484696 5 4917365 [T/C] rs10475277 5 4924195 [A/G] rs501031 5 4928318 [T/C] rs502854 5 4928520 [A/G] rs30452 5 4930407 [T/C] rs654685 5 4936235 [A/G] rs12521477 5 4937880 [T/C] rs609096 5 4938130 [A/G] rs596041 5 4938756 [T/G] rs6868240 5 4938915 [A/C] rs11134086 5 4941242 [T/G] rs30448 5 4945124 [A/G] rs30445 5 4946412 [T/C] rs643466 5 4948424 [A/G] rs466277 5 4948859 [A/G] rs458279 5 4950651 [A/C] rs26847 5 4951614 [T/C] rs7736239 5 4953073 [T/C] rs10070917 5 4955950 [T/C] rs891001 5 4957205 [A/G] rs1366431 5 4959279 [A/G] rs1452028 5 4966602 [T/C] rs1452027 5 4968029 [T/C] rs16874489 5 4971022 [A/G] rs42202 5 4977446 [A/G] rs42401 5 4978270 [T/G] rs30463 5 4987376 [T/C] rs30449 5 4992930 [T/C] rs7734957 5 5003664 [A/G] rs30485 5 5009457 [A/G] rs458084 5 5023441 [A/G] rs16874586 5 5023538 [T/C] rs467075 5 5023977 [A/G] rs465871 5 5024621 [T/G] rs6878673 5 5032533 [T/G] rs16874610 5 5037512 [A/C] NR_026994 LINC01020 Silent rs446464 5 5038540 [T/G] NR_026994 LINC01020 Silent rs272194 5 5051464 [T/C] NR_026994 LINC01020 Silent rs16874638 5 5052953 [A/G] NR_026994 LINC01020 Silent rs272195 5 5052998 [T/C] NR_026994 LINC01020 Silent rs272162 5 5062490 [T/C] NR_026994 LINC01020 Silent rs156251 5 5063242 [T/C] NR_026994 LINC01020 Silent rs270642 5 5072083 [A/G] NR_134266 LINC02121 Silent rs270636 5 5074825 [A/C] NR_134266 LINC02121 Silent rs270629 5 5077133 [T/C] NR_134266 LINC02121 Silent rs3733787 5 5078313 [T/C] NR_134266 LINC02121 Silent rs6866197 5 5080435 [T/C] rs899556 5 5084233 [T/C] rs1382896 5 5089229 [A/G] rs2619799 5 5093172 [T/C] rs1160800 5 5093643 [A/G] rs814797 5 5098840 [A/G] rs16874709 5 5106180 [T/G] rs814790 5 5110692 [A/G] rs2115010 5 5116544 [A/G] rs814783 5 5120745 [T/C] rs861512 5 5120776 [A/G] rs1834925 5 5121337 [T/C] rs9313102 5 5123214 [T/G] rs270188 5 5124149 [A/G] rs270187 5 5124263 [T/C] rs16874791 5 5124549 [A/C] rs10475286 5 5125959 [T/C] rs10042501 5 5126400 [A/G] rs814776 5 5128141 [T/G] rs12516403 5 5129879 [A/G] rs751905 5 5133444 [T/C] NR_109915 CTD-2297D10.2 Silent rs7720806 5 5136207 [T/C] NR_109915 CTD-2297D10.2 Silent rs270206 5 5140970 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs270198 5 5141905 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2291112 5 5142460 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs270193 5 5142768 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1863970 5 5145406 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1863968 5 5146395 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 EXON Missense_M110V,Silent rs10512769 5 5147125 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2255273 5 5147376 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2560412 5 5149621 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs11134095 5 5152447 [T/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs978280 5 5153648 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs16874878 5 5153911 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs922542 5 5154215 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs6555331 5 5154458 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs814775 5 5155357 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs6899080 5 5156655 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs7720897 5 5159316 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs10067690 5 5160481 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs992542 5 5162228 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs7705998 5 5164175 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs270178 5 5165415 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs874428 5 5165870 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1079295 5 5165952 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs997427 5 5167587 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs997428 5 5167648 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs4701693 5 5176672 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs4702234 5 5178624 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs13177816 5 5181634 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs13176907 5 5181829 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs7724547 5 5181928 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1808529 5 5183700 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs10037656 5 5183783 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs12518196 5 5184252 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs4702235 5 5187371 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs11743270 5 5191047 [T/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs12517136 5 5191117 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs12520783 5 5192434 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs871122 5 5192861 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs10039354 5 5195069 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs4701694 5 5195384 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs16874994 5 5195721 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2081852 5 5196007 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs3943879 5 5197553 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs16875033 5 5198567 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1346460 5 5199350 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1428027 5 5199787 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs6555335 5 5200281 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 EXON Synonymous_C450C,Silent rs17762877 5 5200490 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs4702241 5 5202232 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs979708 5 5202753 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs979710 5 5203046 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1428024 5 5203600 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1366165 5 5204149 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs6888758 5 5208254 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs16875054 5 5209210 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 EXON Missense_A486T,Silent rs2019251 5 5209872 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1560063 5 5210050 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs7704912 5 5210315 [T/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1019748 5 5214077 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1560062 5 5221300 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs4702248 5 5222336 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs4702250 5 5224044 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs16875084 5 5224299 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2964444 5 5225032 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2913615 5 5226211 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs12652633 5 5227291 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs16875090 5 5227314 [T/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2913624 5 5232398 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs10067097 5 5234261 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2913633 5 5236356 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1991459 5 5237807 [T/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2964431 5 5239533 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs11742341 5 5239921 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 EXON Synonymous_T802T,Silent rs16875122 5 5242218 [T/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 EXON Missense_R859L,Silent rs17713759 5 5242683 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1019746 5 5244339 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2964426 5 5245062 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1834928 5 5245154 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs934096 5 5246251 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs10038527 5 5246451 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1808528 5 5247857 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs16875141 5 5248501 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs12659315 5 5248799 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs10036107 5 5249101 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs4632765 5 5251047 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2913645 5 5251790 [T/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2964411 5 5254038 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs4323203 5 5260903 [T/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2913655 5 5261011 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2964399 5 5261219 [T/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs1428021 5 5262547 [T/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2913656 5 5263101 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs746636 5 5268673 [T/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs746635 5 5268710 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs959693 5 5270436 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs10044817 5 5273945 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs10045494 5 5274415 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs7341133 5 5277095 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs13178690 5 5277259 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs10512778 5 5279592 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs10512779 5 5281408 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs16875221 5 5282051 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs11134100 5 5283234 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs10512780 5 5283260 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs16875241 5 5286424 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs16875244 5 5287739 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs4076657 5 5290195 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs11134106 5 5290797 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs6555340 5 5292821 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs16875287 5 5294187 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs7701192 5 5298350 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs12518997 5 5302501 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs12518998 5 5302512 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs11134110 5 5303614 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs4702257 5 5309697 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs4702258 5 5309811 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs7721079 5 5314703 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs4128586 5 5316866 [T/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2964154 5 5317110 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs2964478 5 5317882 [A/G] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs6885895 5 5318581 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 Silent,Silent rs3806872 5 5320256 [A/C] NM_139056,NR_136935 ADAMTS16,ADAMTS16 EXON Silent,Silent rs11134111 5 5323994 [A/G] rs3923919 5 5324172 [T/C] rs10512787 5 5324373 [A/C] rs16875333 5 5324983 [A/C] rs10060293 5 5325727 [A/G] rs7725935 5 5326138 [A/G] rs11739886 5 5326788 [A/C] rs2964474 5 5328297 [T/C] rs7731357 5 5328681 [T/C] rs2964153 5 5329658 [A/G] rs11747342 5 5335483 [T/C] rs16875352 5 5337184 [T/C] rs16875358 5 5337933 [T/C] rs2964150 5 5340927 [T/C] rs2964149 5 5344745 [A/G] rs2964467 5 5348009 [A/G] rs2964145 5 5348640 [A/G] rs7735787 5 5350456 [A/G] rs7723605 5 5354615 [T/C] rs4540151 5 5358146 [T/C] rs2964459 5 5361469 [T/G] rs16875423 5 5361557 [T/C] rs12655520 5 5363136 [A/C] rs10474786 5 5365240 [A/G] rs13172631 5 5371590 [T/C] rs17785206 5 5373748 [T/C] rs2964453 5 5374574 [A/G] rs6884256 5 5376984 [T/C] rs11748854 5 5378905 [A/G] rs6891687 5 5383342 [T/G] rs16875511 5 5385388 [T/C] rs11134112 5 5388969 [T/G] rs17785923 5 5390804 [A/G] rs2964137 5 5396166 [A/G] rs1863943 5 5397165 [T/C] rs2964135 5 5398279 [T/C] rs2964437 5 5398894 [T/G] rs6868526 5 5399472 [T/C] rs2964132 5 5401773 [T/G] rs16875556 5 5402163 [A/G] rs4702267 5 5404664 [A/C] rs2913341 5 5405699 [T/C] rs1078266 5 5406467 [A/G] rs2964383 5 5406529 [A/C] rs2964475 5 5407814 [T/G] rs2913356 5 5415012 [T/C] rs2913364 5 5416398 [T/C] rs2964163 5 5418792 [T/C] rs2399696 5 5419547 [T/C] rs2578550 5 5437380 [T/C] NM_015325 ICE1 Silent rs4702269 5 5447607 [A/G] NM_015325 ICE1 EXON Synonymous_E164E rs16875582 5 5449333 [T/G] NM_015325 ICE1 Silent rs2578553 5 5449367 [T/C] NM_015325 ICE1 Silent rs16875597 5 5460434 [T/C] NM_015325 ICE1 Silent rs2578565 5 5460569 [T/C] NM_015325 ICE1 EXON Synonymous_Y374Y rs2578500 5 5462148 [A/G] NM_015325 ICE1 EXON Missense_V901I rs3806873 5 5462607 [A/G] NM_015325 ICE1 EXON Missense_T1054A rs3806874 5 5462620 [A/G] NM_015325 ICE1 EXON Missense_G1058D rs10065646 5 5464237 [A/C] NM_015325 ICE1 EXON Missense_Q1597P rs3747731 5 5464300 [T/C] NM_015325 ICE1 EXON Missense_P1618L rs16875609 5 5470026 [T/C] NM_015325 ICE1 Silent rs3747730 5 5475858 [A/G] NM_015325 ICE1 Silent rs252940 5 5495373 [A/G] rs13181223 5 5496203 [A/G] rs252938 5 5496480 [T/C] rs189696 5 5504341 [T/C] rs2619855 5 5504842 [T/C] rs252930 5 5509703 [A/C] rs10045041 5 5513625 [T/C] rs252926 5 5513747 [T/C] rs504750 5 5514031 [T/C] rs2652715 5 5514517 [A/G] rs2652703 5 5524200 [T/C] rs2591699 5 5533625 [T/C] rs10070649 5 5535818 [T/C] rs16875692 5 5536047 [A/G] rs17770324 5 5539266 [A/G] rs1871473 5 5546157 [T/G] rs252838 5 5560070 [A/G] rs10039912 5 5566984 [T/C] rs2652701 5 5566987 [A/G] rs11741306 5 5569317 [T/C] rs16875749 5 5569663 [T/C] rs252613 5 5570011 [A/C] rs11741289 5 5577176 [A/G] rs13154779 5 5578527 [T/C] rs16875781 5 5579270 [T/C] rs246760 5 5580216 [T/C] rs246764 5 5581522 [A/G] rs181773 5 5584551 [A/G] rs153264 5 5585343 [T/C] rs585394 5 5591903 [T/C] rs16875838 5 5597328 [T/C] rs11739751 5 5598181 [T/C] rs252596 5 5600683 [T/C] rs2560286 5 5601717 [T/C] rs12522553 5 5601744 [A/G] rs1318543 5 5602308 [A/G] rs2438479 5 5602530 [T/C] rs2928229 5 5602673 [A/G] rs9313114 5 5605051 [T/C] rs378932 5 5609695 [A/C] rs252606 5 5611132 [A/C] rs2560290 5 5611791 [A/G] rs2560291 5 5611834 [T/C] rs422576 5 5611992 [A/G] rs13185585 5 5614515 [T/G] rs394842 5 5615414 [A/G] rs2255659 5 5619500 [T/C] rs7703207 5 5621914 [T/C] rs153269 5 5622187 [T/C] rs153270 5 5622224 [T/C] rs7715115 5 5624937 [A/C] rs252609 5 5628443 [A/G] rs34123 5 5628903 [T/G] rs10462632 5 5629110 [A/G] rs10062459 5 5636458 [A/C] rs13181152 5 5638245 [A/G] rs6865834 5 5641116 [A/C] rs10052145 5 5647018 [T/C] rs13182121 5 5649467 [T/C] rs17791535 5 5649753 [A/G] rs7733256 5 5662750 [T/C] rs256358 5 5670085 [T/C] rs256360 5 5672577 [A/G] rs11748708 5 5678997 [T/C] rs11959645 5 5680337 [A/G] rs11134122 5 5686448 [A/G] rs10512804 5 5689218 [T/C] rs7736476 5 5690605 [A/C] rs13157338 5 5692072 [T/C] rs16876026 5 5694586 [A/G] rs17736004 5 5703184 [A/G] rs16876028 5 5703521 [T/C] rs11948250 5 5704234 [A/G] rs12110260 5 5711184 [T/G] rs1560073 5 5713635 [T/C] rs7727470 5 5713766 [T/C] rs7725455 5 5723290 [T/C] rs4143541 5 5725162 [T/C] rs7725206 5 5729063 [T/C] rs2895450 5 5737475 [A/G] rs7722440 5 5740672 [A/C] rs16876128 5 5741376 [A/C] rs406792 5 5743661 [T/C] rs10044391 5 5744949 [A/G] rs449492 5 5750355 [A/G] rs434192 5 5750925 [T/C] rs11743797 5 5761030 [A/G] rs34950 5 5768140 [A/G] rs10475307 5 5770079 [A/G] rs3852153 5 5771161 [A/G] rs16876243 5 5772527 [T/G] rs16876246 5 5773005 [T/C] rs16876248 5 5773139 [A/G] rs166285 5 5779953 [T/C] rs6897110 5 5786026 [T/G] rs6897118 5 5786036 [T/G] rs187632 5 5786702 [A/G] rs10036598 5 5789072 [T/C] rs42286 5 5790928 [A/G] rs32566 5 5792507 [T/C] rs16876293 5 5792669 [T/C] rs28165 5 5792720 [A/G] rs40587 5 5797519 [T/C] rs32558 5 5798853 [T/C] rs4701707 5 5800497 [A/G] rs26806 5 5801024 [T/C] rs3864249 5 5802056 [T/C] rs4702288 5 5802680 [T/C] rs10063530 5 5802978 [T/C] rs7711899 5 5806153 [T/C] rs9313125 5 5806470 [A/G] rs32553 5 5806875 [T/C] rs21757 5 5808963 [T/C] rs32550 5 5809047 [A/G] rs6867853 5 5810732 [A/G] rs2617562 5 5811074 [T/C] rs1864117 5 5818164 [A/G] rs10068484 5 5820386 [A/C] rs6892546 5 5820530 [T/C] rs3852160 5 5822647 [T/C] rs16876357 5 5823575 [T/C] rs40516 5 5825953 [T/C] rs35741 5 5826272 [T/G] rs188684 5 5828648 [T/C] rs309424 5 5828805 [T/C] rs7722388 5 5829193 [A/G] rs257073 5 5834614 [A/G] rs3852162 5 5836435 [T/C] rs309421 5 5838642 [A/G] rs218317 5 5838682 [A/G] rs182552 5 5839032 [T/C] rs2560461 5 5848736 [T/C] rs2560483 5 5852963 [A/G] rs10035799 5 5853123 [T/C] rs16876434 5 5854993 [T/C] rs7715747 5 5855016 [T/C] rs2652483 5 5855519 [T/C] rs17746450 5 5856815 [T/C] rs10512842 5 5857554 [A/G] rs1628345 5 5857792 [T/C] rs2561858 5 5859422 [A/C] rs2652486 5 5860950 [T/C] rs309016 5 5863733 [T/C] rs12653640 5 5865100 [T/C] rs16876469 5 5879419 [A/C] rs1913763 5 5881234 [A/G] rs10512838 5 5883115 [A/G] rs1875512 5 5890342 [A/G] rs1174930 5 5891878 [T/C] rs1174931 5 5893255 [T/C] rs2256415 5 5894870 [A/G] rs1032748 5 5903890 [A/G] rs1306085 5 5904424 [T/G] rs2173946 5 5910657 [A/G] rs17815761 5 5911337 [A/G] rs10454950 5 5912054 [T/C] rs13188105 5 5916224 [T/C] rs2455385 5 5916337 [T/C] rs10462810 5 5922597 [T/G] rs2673846 5 5922663 [A/G] rs10512833 5 5927796 [T/C] rs16876615 5 5931513 [A/G] rs1174900 5 5936810 [A/G] rs1174901 5 5937776 [T/C] rs10068316 5 5938780 [A/G] rs982248 5 5943182 [T/C] rs657865 5 5943861 [T/C] rs216578 5 5951796 [A/G] rs160126 5 5956806 [A/G] rs11948091 5 5956826 [A/C] rs1366154 5 5959444 [A/G] rs160134 5 5966730 [A/G] rs10057959 5 5971019 [T/C] rs10474793 5 5972299 [T/C] rs302913 5 5973626 [T/C] rs6887254 5 5975333 [A/G] rs10213777 5 5977222 [A/G] rs306254 5 5981228 [A/G] rs11741359 5 5988965 [A/G] rs159981 5 5989136 [T/C] rs12516740 5 5989446 [A/G] rs17818111 5 5998212 [A/G] rs17767636 5 6009018 [A/G] rs302899 5 6010591 [A/G] rs458635 5 6012340 [T/C] rs2434744 5 6016507 [A/G] rs419119 5 6021846 [A/C] rs4377680 5 6022683 [T/C] rs457990 5 6023131 [A/G] rs3846567 5 6023338 [T/G] rs461240 5 6024988 [T/C] rs154814 5 6028250 [A/C] rs10069535 5 6030719 [A/G] rs173577 5 6034364 [A/G] rs40111 5 6034845 [T/C] rs10051928 5 6036454 [A/G] rs16876890 5 6038449 [T/C] rs1027249 5 6038726 [A/G] rs28047 5 6041659 [A/G] rs17769749 5 6043189 [A/G] rs13166306 5 6043624 [A/G] rs26647 5 6043644 [T/C] rs10064690 5 6044675 [A/G] rs17821004 5 6045849 [A/G] rs6878493 5 6050231 [A/G] rs11134135 5 6054601 [A/G] rs12187733 5 6058009 [A/G] rs16876913 5 6075956 [A/G] rs17770545 5 6082486 [T/C] rs12515958 5 6083408 [T/C] rs2115365 5 6084659 [A/G] rs307177 5 6087348 [T/C] rs307176 5 6087464 [T/C] rs11134138 5 6093701 [T/C] rs438864 5 6104032 [A/G] rs409978 5 6104208 [T/C] rs301782 5 6107249 [A/G] rs301772 5 6110760 [T/C] rs2398255 5 6121018 [T/G] rs9313144 5 6132166 [T/C] rs6861277 5 6136125 [T/C] rs4334845 5 6141688 [A/G] rs16876953 5 6142003 [A/G] rs12652811 5 6142364 [T/G] rs12658976 5 6148345 [T/C] rs10077859 5 6156355 [A/G] rs12657021 5 6158213 [A/G] rs993046 5 6162445 [T/C] rs11750309 5 6164849 [T/C] rs1560178 5 6167165 [T/C] rs11134144 5 6167854 [T/C] rs10059895 5 6172968 [A/G] rs11953803 5 6174586 [A/G] rs11745650 5 6176473 [A/G] rs2964722 5 6179771 [T/C] rs10073376 5 6189781 [T/G] rs2937785 5 6197044 [T/C] rs2964767 5 6203128 [A/G] rs11134145 5 6204971 [T/C] rs11134147 5 6205134 [A/G] rs1875542 5 6206875 [T/G] rs4143217 5 6208293 [A/G] rs2937791 5 6212193 [T/C] rs2964739 5 6212759 [T/C] rs7727548 5 6216046 [T/G] rs7726513 5 6218907 [A/G] rs16877061 5 6219665 [T/C] rs2964755 5 6235302 [T/C] rs1870082 5 6247401 [A/G] rs1598734 5 6248674 [T/C] rs2124935 5 6249440 [T/C] rs2925721 5 6251548 [T/C] rs1457120 5 6252929 [T/C] rs4702325 5 6257553 [T/C] rs2914757 5 6257996 [T/C] rs4702326 5 6262981 [A/C] rs1870083 5 6264448 [T/G] rs11956792 5 6265471 [A/C] rs3846569 5 6266723 [A/G] rs1457122 5 6273004 [T/G] rs1551572 5 6274436 [T/C] rs4701720 5 6276222 [T/C] rs6866699 5 6277738 [T/C] rs2061280 5 6279339 [T/C] rs2914752 5 6281648 [T/C] rs2914749 5 6285723 [A/G] rs2925703 5 6286005 [A/C] rs2925702 5 6286955 [T/C] rs1379305 5 6289200 [A/G] rs2914746 5 6296991 [A/G] rs7703162 5 6301470 [T/G] rs12513969 5 6302491 [A/G] rs2242132 5 6307991 [T/C] rs10055872 5 6310014 [A/C] rs10050365 5 6310995 [T/C] NR_028351 LINC02145 EXON Silent rs10050369 5 6311020 [T/C] NR_028351 LINC02145 EXON Silent rs10059734 5 6311100 [T/C] NR_028351 LINC02145 EXON Silent rs17825532 5 6311896 [A/G] NR_028351 LINC02145 EXON Silent rs1864218 5 6315439 [T/C] NR_028351 LINC02145 Silent rs13166082 5 6316676 [A/G] NR_028351 LINC02145 Silent rs7714333 5 6317260 [A/G] NR_028351 LINC02145 Silent rs12716179 5 6317306 [T/C] NR_028351 LINC02145 Silent rs12520404 5 6323989 [A/G] NR_028351 LINC02145 Silent rs13177370 5 6325444 [T/C] NR_028351 LINC02145 Silent rs4345283 5 6325850 [A/C] NR_028351 LINC02145 Silent rs1428986 5 6326059 [A/G] NR_028351 LINC02145 Silent rs6872084 5 6328426 [T/C] NR_028351 LINC02145 Silent rs7731289 5 6335043 [T/C] NR_028351 LINC02145 Silent rs13189546 5 6336397 [A/C] NR_028351 LINC02145 Silent rs271403 5 6340693 [A/G] rs10512850 5 6343019 [A/C] rs271409 5 6344389 [T/C] rs7736640 5 6345759 [A/G] rs271413 5 6347695 [T/C] rs271418 5 6353024 [T/C] rs10040610 5 6353815 [T/C] rs271421 5 6354132 [T/C] rs271422 5 6355707 [T/C] rs7711308 5 6358449 [A/G] rs4701724 5 6365689 [T/C] rs11949673 5 6371230 [A/G] rs4592 5 6372248 [A/G] NM_032286 MED10 EXON Silent rs17831845 5 6373100 [A/G] NM_032286 MED10 Silent rs2455146 5 6374004 [A/G] NM_032286 MED10 Silent rs17831958 5 6377293 [T/C] NM_032286 MED10 EXON Synonymous_P64P rs10052685 5 6377973 [T/C] NM_032286 MED10 Silent rs7702608 5 6381817 [A/G] rs11134158 5 6383318 [T/C] rs4701728 5 6386041 [A/G] rs13361971 5 6392452 [A/G] rs12189308 5 6392602 [A/G] rs10050504 5 6393771 [A/G] rs4702345 5 6395712 [T/C] rs12153196 5 6398254 [T/C] rs6869702 5 6401135 [A/G] rs10056261 5 6401960 [A/G] rs1393067 5 6402598 [T/C] rs2398140 5 6404896 [T/C] rs17775764 5 6405678 [A/G] rs12654055 5 6410448 [T/C] rs17775925 5 6413449 [T/C] rs16877282 5 6415844 [A/G] rs16877284 5 6418287 [A/G] rs16877286 5 6418689 [T/C] rs16877287 5 6418912 [A/G] rs7702037 5 6421609 [T/C] rs7712764 5 6423602 [T/C] rs7737864 5 6424822 [A/G] rs10038921 5 6428242 [A/G] rs6869437 5 6428642 [A/G] rs9687391 5 6430604 [T/C] rs7714347 5 6432740 [A/C] rs7734853 5 6438396 [A/G] rs824634 5 6439663 [T/C] rs169250 5 6450203 [A/C] NM_001145161 UBE2QL1 Silent rs4701734 5 6456627 [A/G] NM_001145161 UBE2QL1 Silent rs2651945 5 6457563 [T/C] NM_001145161 UBE2QL1 Silent rs169251 5 6461429 [T/C] NM_001145161 UBE2QL1 Silent rs272479 5 6464724 [A/G] NM_001145161 UBE2QL1 Silent rs272485 5 6469031 [T/C] NM_001145161 UBE2QL1 Silent rs490320 5 6471038 [A/G] NM_001145161 UBE2QL1 Silent rs507971 5 6471344 [T/C] NM_001145161 UBE2QL1 Silent rs12652806 5 6473308 [T/C] NM_001145161 UBE2QL1 Silent rs824619 5 6473810 [A/C] NM_001145161 UBE2QL1 Silent rs824622 5 6475025 [A/G] NM_001145161 UBE2QL1 Silent rs16877364 5 6480993 [T/C] NM_001145161 UBE2QL1 Silent rs272456 5 6484012 [T/C] NM_001145161 UBE2QL1 Silent rs10071072 5 6486876 [T/G] NM_001145161 UBE2QL1 Silent rs272461 5 6488117 [A/G] NM_001145161 UBE2QL1 Silent rs10044719 5 6494449 [T/C] NM_001145161 UBE2QL1 EXON Silent rs885469 5 6494933 [T/C] NM_001145161 UBE2QL1 EXON Silent rs883525 5 6495579 [T/C] NM_001145161 UBE2QL1 EXON Silent rs11134163 5 6501350 [A/C] rs9784711 5 6502499 [T/C] rs11948895 5 6503085 [T/C] rs9765361 5 6504171 [T/C] rs17834269 5 6505467 [T/C] rs573546 5 6511314 [T/C] rs4702357 5 6512465 [T/C] rs566829 5 6517509 [A/G] rs487740 5 6518618 [T/C] rs11748341 5 6518928 [T/C] rs10057455 5 6520414 [T/C] rs4702359 5 6521202 [A/G] rs11954200 5 6521548 [A/G] rs11742039 5 6521824 [T/G] rs563624 5 6521837 [A/C] rs538938 5 6522221 [T/C] rs4702360 5 6522653 [A/G] rs534384 5 6522711 [A/G] rs529524 5 6523738 [A/G] rs540027 5 6528465 [T/C] rs514041 5 6529238 [A/G] rs6881323 5 6531185 [T/C] rs884475 5 6532191 [A/C] rs516853 5 6539175 [T/C] rs12189073 5 6540593 [A/G] rs12189254 5 6540747 [T/C] rs17778905 5 6547267 [A/C] rs13436933 5 6547317 [A/G] rs2617534 5 6548889 [A/G] rs11134165 5 6549378 [T/C] rs6887455 5 6549456 [A/C] rs11960029 5 6550709 [T/C] rs12654436 5 6552278 [A/G] rs524861 5 6552513 [A/C] rs474953 5 6556587 [A/C] rs493944 5 6558291 [T/C] rs13165570 5 6559304 [A/G] rs11743719 5 6559533 [A/G] rs567431 5 6560041 [T/C] rs477391 5 6562950 [A/G] rs532983 5 6568392 [A/C] rs16877577 5 6572315 [A/C] rs501592 5 6572542 [T/G] rs522335 5 6572878 [T/C] rs532737 5 6573663 [A/G] rs4702370 5 6574088 [A/G] rs10055883 5 6574609 [T/G] rs10058390 5 6576320 [A/G] rs13152888 5 6576489 [T/G] rs7701143 5 6577009 [A/G] rs551574 5 6578382 [T/C] rs498932 5 6580030 [T/C] rs503679 5 6580584 [A/G] rs7735244 5 6584248 [T/C] NR_024423,NR_024424 LINC01018,LINC01018 Silent,Silent rs545493 5 6597622 [T/C] rs7729233 5 6597810 [T/C] rs11743743 5 6598553 [A/C] rs7733507 5 6598771 [T/G] rs6876835 5 6599222 [A/G] rs3776448 5 6599940 [T/C] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 EXON Silent,Silent,Silent rs3822434 5 6600150 [A/G] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 EXON Synonymous_D731D,Synonymous_D696D,Silent rs4701741 5 6601309 [T/C] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 Silent,Silent,Silent rs2303711 5 6602544 [T/C] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 Silent,Silent,Silent rs2303708 5 6604329 [T/C] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 EXON Missense_V627I,Missense_V592I,Silent rs13181449 5 6604787 [T/C] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 EXON Synonymous_T583T,Synonymous_T548T,Silent rs714713 5 6608361 [A/C] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 Silent,Silent,Silent rs10475336 5 6609066 [T/C] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 Silent,Silent,Silent rs3822432 5 6609112 [A/G] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 Silent,Silent,Silent rs11741091 5 6610911 [T/C] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 Silent,Silent,Silent rs567289 5 6612464 [A/G] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 Silent,Silent,Silent rs4701742 5 6613827 [T/C] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 Silent,Silent,Silent rs529439 5 6616277 [A/G] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 Silent,Silent,Silent rs12522757 5 6620844 [A/C] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 Silent,Silent,Silent rs2303705 5 6622017 [T/G] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 Silent,Silent,Silent rs12691276 5 6623085 [T/C] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 Silent,Silent,Silent rs518673 5 6629930 [A/G] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 Silent,Silent,Silent rs8192120 5 6632320 [A/C] NM_017755,NM_001193455,NR_037947 NSUN2,NSUN2,NSUN2 Silent,Silent,Silent rs477930 5 6635882 [T/G] NR_136739,NM_001324322,NM_001324323,NM_001047 SRD5A1,SRD5A1,SRD5A1,SRD5A1 Silent,Silent,Silent,Silent rs485614 5 6642426 [A/G] NR_136739,NM_001324322,NM_001324323,NM_001047 SRD5A1,SRD5A1,SRD5A1,SRD5A1 Silent,Silent,Silent,Silent rs166050 5 6643847 [A/G] NR_136739,NM_001324322,NM_001324323,NM_001047 SRD5A1,SRD5A1,SRD5A1,SRD5A1 Silent,Silent,Silent,Silent rs8192180 5 6645147 [T/C] NR_136739,NM_001324322,NM_001324323,NM_001047 SRD5A1,SRD5A1,SRD5A1,SRD5A1 EXON Silent,Silent,Silent,Silent rs3822430 5 6651970 [A/G] NR_136739,NM_001324322,NM_001324323,NM_001047 SRD5A1,SRD5A1,SRD5A1,SRD5A1 EXON Silent,Silent,Synonymous_P30P,Synonymous_P103P rs3733773 5 6652252 [A/G] NR_136739,NM_001324322,NM_001324323,NM_001047 SRD5A1,SRD5A1,SRD5A1,SRD5A1 Silent,Silent,Silent,Silent rs8192189 5 6653366 [T/C] NR_136739,NM_001324322,NM_001324323,NM_001047 SRD5A1,SRD5A1,SRD5A1,SRD5A1 Silent,Silent,Silent,Silent rs8192207 5 6656161 [T/C] NR_136739,NM_001324322,NM_001324323,NM_001047 SRD5A1,SRD5A1,SRD5A1,SRD5A1 Silent,Silent,Silent,Silent rs248800 5 6660400 [A/C] NR_136739,NM_001324322,NM_001324323,NM_001047 SRD5A1,SRD5A1,SRD5A1,SRD5A1 Silent,Silent,Silent,Silent rs6884552 5 6661966 [T/C] NR_136739,NM_001324322,NM_001324323,NM_001047 SRD5A1,SRD5A1,SRD5A1,SRD5A1 Silent,Silent,Silent,Silent rs3797179 5 6666922 [A/G] NR_136739,NM_001324322,NM_001324323,NM_001047 SRD5A1,SRD5A1,SRD5A1,SRD5A1 Silent,Silent,Silent,Silent rs6872996 5 6667102 [T/C] NR_136739,NM_001324322,NM_001324323,NM_001047 SRD5A1,SRD5A1,SRD5A1,SRD5A1 Silent,Silent,Silent,Silent rs8192256 5 6669336 [T/C] NR_136739,NM_001324322,NM_001324323,NM_001047 SRD5A1,SRD5A1,SRD5A1,SRD5A1 EXON Silent,Silent,Silent,Silent rs39848 5 6669762 [T/C] rs16877779 5 6670649 [A/G] rs39847 5 6671959 [A/G] rs12716180 5 6672694 [T/C] rs30434 5 6673322 [T/C] rs1651071 5 6676931 [A/G] rs274657 5 6680115 [A/C] rs10512874 5 6683000 [A/G] rs11744535 5 6684954 [T/C] rs371869 5 6687557 [A/G] NR_103771 LINC02102 Silent rs1551538 5 6688275 [A/G] NR_103771 LINC02102 Silent rs6555406 5 6694692 [A/G] NR_103771 LINC02102 Silent rs7726777 5 6695765 [A/G] NR_103771 LINC02102 Silent rs274661 5 6704848 [T/C] NR_103771 LINC02102 Silent rs4701750 5 6708483 [A/G] rs274671 5 6712533 [T/G] rs274714 5 6723546 [T/C] NM_001171805,NM_006999 TENT4A,TENT4A Silent,Silent rs16877813 5 6724546 [A/G] NM_001171805,NM_006999 TENT4A,TENT4A Silent,Silent rs877238 5 6729695 [T/C] NM_001171805,NM_006999 TENT4A,TENT4A Silent,Silent rs28363340 5 6735844 [A/G] NM_001171805,NM_006999 TENT4A,TENT4A Silent,Silent rs416847 5 6739567 [T/C] NM_001171805,NM_006999 TENT4A,TENT4A Silent,Silent rs187994 5 6742168 [A/G] NM_001171805,NM_006999 TENT4A,TENT4A Silent,Silent rs2290616 5 6747104 [T/C] NM_001171805,NM_006999 TENT4A,TENT4A Silent,Silent rs274674 5 6755460 [T/C] NM_001171805,NM_006999 TENT4A,TENT4A EXON Silent,Silent rs10059847 5 6757720 [T/C] rs13163920 5 6759714 [T/C] rs2397977 5 6760499 [T/C] rs12188231 5 6761511 [T/G] rs12520016 5 6767312 [T/G] rs1552914 5 6769016 [T/C] rs11947998 5 6772593 [T/C] rs429161 5 6777769 [T/C] rs897712 5 6785435 [A/G] rs274645 5 6786308 [A/G] rs4702390 5 6786553 [T/C] rs751594 5 6790678 [T/C] rs274651 5 6790691 [T/G] rs106415 5 6792839 [T/C] rs1004758 5 6792985 [T/G] rs716976 5 6793959 [A/G] rs13177725 5 6795764 [A/G] rs4702392 5 6796405 [A/C] NR_146281 LINC02236 EXON Silent rs450804 5 6797096 [T/C] NR_146281 LINC02236 Silent rs6885579 5 6797422 [A/C] NR_146281 LINC02236 Silent rs11956100 5 6802179 [T/C] NR_146281 LINC02236 Silent rs12523241 5 6803243 [A/G] NR_146281 LINC02236 Silent rs11949128 5 6804983 [A/G] NR_146281 LINC02236 Silent rs275460 5 6806216 [A/G] NR_146281 LINC02236 Silent rs7728254 5 6810950 [A/G] NR_146281 LINC02236 Silent rs16877995 5 6812137 [A/G] NR_146281 LINC02236 Silent rs275456 5 6813937 [T/G] NR_146281 LINC02236 Silent rs12109729 5 6817709 [T/C] NR_146281 LINC02236 Silent rs2047321 5 6818844 [T/C] NR_146281 LINC02236 Silent rs2047322 5 6818876 [A/G] NR_146281 LINC02236 Silent rs13174522 5 6820161 [A/G] NR_146281 LINC02236 Silent rs10044678 5 6820833 [T/C] NR_146281 LINC02236 Silent rs1566039 5 6821914 [A/G] NR_146281 LINC02236 Silent rs275447 5 6825016 [A/G] NR_146281 LINC02236 Silent rs16878029 5 6826269 [A/G] NR_146281 LINC02236 Silent rs275442 5 6827513 [T/C] rs2453805 5 6828995 [A/G] rs16878054 5 6829242 [A/G] rs275486 5 6829382 [T/C] rs275480 5 6832480 [T/C] rs275468 5 6838445 [A/G] rs275467 5 6838589 [A/G] rs10053085 5 6842007 [A/G] rs1993450 5 6842066 [T/C] rs6893958 5 6842842 [A/G] rs870347 5 6845035 [A/C] rs11740531 5 6845811 [T/C] rs16878070 5 6850596 [A/G] rs275490 5 6852600 [T/C] rs275493 5 6854074 [A/G] rs9313172 5 6854290 [A/G] rs275510 5 6859895 [T/C] rs951476 5 6859946 [A/G] rs12522644 5 6864120 [A/G] rs275499 5 6864573 [A/G] rs721632 5 6864785 [T/C] rs12513764 5 6865801 [A/G] rs275502 5 6866673 [A/G] rs275504 5 6867590 [A/G] rs997182 5 6869021 [A/G] rs275430 5 6870971 [A/G] rs275425 5 6872924 [A/G] rs275424 5 6873013 [A/G] rs2397770 5 6873930 [T/G] rs16878119 5 6878651 [A/G] rs7703668 5 6879564 [A/G] rs275438 5 6881857 [A/G] rs12514931 5 6884986 [A/C] rs13156798 5 6887228 [A/G] rs10512890 5 6892417 [A/G] rs11959635 5 6894060 [A/G] rs2894967 5 6900466 [A/G] rs1353502 5 6902045 [T/G] rs1353500 5 6902924 [T/C] rs10512902 5 6903471 [T/C] rs903863 5 6907892 [A/G] rs9313175 5 6912705 [T/G] rs12656353 5 6913626 [T/G] rs2397719 5 6922386 [T/C] rs2397718 5 6940857 [A/G] rs11134195 5 6943022 [A/G] rs6862164 5 6944267 [A/G] rs6884863 5 6950547 [A/G] rs1845852 5 6952197 [T/C] rs7727425 5 6959721 [A/G] rs12516580 5 6962368 [A/C] rs7706332 5 6963155 [A/G] rs7729658 5 6963922 [T/C] rs1155297 5 6966304 [A/G] rs16878239 5 6972638 [A/G] rs17192980 5 6977768 [T/C] rs1353499 5 6978190 [T/C] rs1353498 5 6981399 [T/G] rs1496404 5 6984426 [A/G] rs6873965 5 6985430 [T/C] rs13180321 5 6993552 [T/G] rs11748242 5 6995964 [A/C] rs4446428 5 7005949 [A/G] rs4312853 5 7006254 [A/G] rs6555424 5 7018060 [A/G] rs17806359 5 7018136 [A/C] rs10866576 5 7019507 [A/G] rs12658529 5 7023296 [T/C] rs11134199 5 7025264 [T/G] rs4702421 5 7025546 [T/C] rs7705045 5 7044847 [T/C] rs7711636 5 7048314 [T/C] rs6859571 5 7053506 [T/C] rs10462830 5 7054372 [A/G] rs13357446 5 7065257 [A/G] rs7736268 5 7071229 [T/C] rs1874455 5 7075590 [T/C] rs13190346 5 7083694 [A/G] rs4702423 5 7087890 [T/C] rs754335 5 7088994 [T/C] rs2029907 5 7091161 [T/C] rs9654456 5 7093653 [T/C] rs7725101 5 7099016 [T/C] rs6861024 5 7101299 [T/C] rs17194818 5 7108672 [T/C] rs16878349 5 7111255 [A/G] rs13190668 5 7113315 [T/C] rs2047313 5 7116244 [A/G] rs7709128 5 7118376 [A/G] rs13161773 5 7118462 [A/G] rs6885291 5 7121294 [T/G] rs903848 5 7122604 [A/G] rs16878386 5 7125022 [T/C] rs16878407 5 7133273 [T/C] rs1496361 5 7136893 [T/G] rs11134203 5 7138170 [T/C] rs4702433 5 7142618 [A/C] rs7725195 5 7148048 [A/G] rs7709141 5 7148491 [A/G] rs7709479 5 7148725 [T/G] rs16878428 5 7149071 [T/C] rs1566035 5 7149265 [T/C] rs13168690 5 7149777 [T/C] rs10035660 5 7155116 [T/G] rs4702435 5 7155612 [T/C] rs4701770 5 7155671 [A/G] rs12659620 5 7155958 [T/C] rs7444602 5 7157361 [A/C] rs9791081 5 7158473 [A/G] rs11749475 5 7164445 [T/C] rs16878438 5 7164967 [A/G] rs16878441 5 7166072 [T/C] rs7713650 5 7169448 [T/C] rs7727403 5 7169851 [T/G] rs11745983 5 7178644 [A/G] rs13166960 5 7179551 [A/G] rs6420053 5 7183381 [A/G] rs10051593 5 7184639 [T/G] rs13155334 5 7189524 [A/C] rs9313179 5 7189925 [A/C] rs4702440 5 7191074 [T/C] rs10058673 5 7202086 [A/G] rs16900420 5 7204616 [A/G] rs11740932 5 7204935 [T/C] rs10062310 5 7209108 [A/G] rs4569841 5 7210079 [T/C] rs13360543 5 7210795 [T/G] rs13186772 5 7216226 [T/C] rs13155746 5 7218137 [A/G] rs6899057 5 7226862 [T/C] rs4382132 5 7230432 [T/C] rs4235576 5 7238212 [A/G] rs16878508 5 7243197 [A/G] rs4276378 5 7244491 [A/G] rs9313184 5 7250769 [T/C] rs9986256 5 7252066 [T/C] rs6555443 5 7252807 [T/C] rs13360728 5 7253812 [T/C] rs10462834 5 7261197 [A/G] rs6555448 5 7270306 [T/C] rs10462838 5 7270417 [T/C] rs16878542 5 7271817 [T/C] rs17810712 5 7275068 [A/G] rs16878549 5 7279325 [T/C] rs4266373 5 7281508 [A/G] rs10067993 5 7281915 [A/G] rs17842508 5 7299845 [T/C] rs6868691 5 7303877 [A/G] NR_033906 LOC442132 EXON Silent rs10475365 5 7317421 [A/G] rs4132671 5 7317925 [A/G] rs4702457 5 7324451 [A/C] rs4631151 5 7325450 [A/G] rs6887339 5 7326039 [A/G] rs1505083 5 7336886 [A/C] rs4492081 5 7339482 [T/C] rs1505080 5 7345847 [A/G] rs3812025 5 7347593 [A/C] NR_134277 LINC02123 EXON Silent rs7710093 5 7352602 [A/G] rs884267 5 7356978 [A/G] rs6886365 5 7357767 [A/G] rs17207026 5 7359857 [T/C] rs11134224 5 7364187 [A/G] rs10036962 5 7367623 [A/G] rs13172324 5 7368845 [T/C] rs11949012 5 7369839 [A/G] rs10065659 5 7375754 [A/C] rs6875496 5 7383873 [A/G] rs12514566 5 7391462 [A/G] rs13153439 5 7398546 [A/C] NM_020546 ADCY2 Silent rs10512920 5 7402561 [T/G] NM_020546 ADCY2 Silent rs10061752 5 7418630 [T/C] NM_020546 ADCY2 Silent rs6872422 5 7422768 [T/G] NM_020546 ADCY2 Silent rs13175846 5 7424672 [T/C] NM_020546 ADCY2 Silent rs17813652 5 7425788 [T/C] NM_020546 ADCY2 Silent rs7710510 5 7427289 [T/C] NM_020546 ADCY2 Silent rs7733194 5 7441829 [A/G] NM_020546 ADCY2 Silent rs1025291 5 7445289 [A/G] NM_020546 ADCY2 Silent rs902522 5 7447405 [A/G] NM_020546 ADCY2 Silent rs13175786 5 7447525 [T/C] NM_020546 ADCY2 Silent rs16878658 5 7456622 [A/G] NM_020546 ADCY2 Silent rs7712809 5 7459043 [A/G] NM_020546 ADCY2 Silent rs34843 5 7460236 [T/G] NM_020546 ADCY2 Silent rs26737 5 7463625 [A/C] NM_020546 ADCY2 Silent rs26739 5 7466176 [A/G] NM_020546 ADCY2 Silent rs10063916 5 7466743 [A/G] NM_020546 ADCY2 Silent rs27378 5 7468560 [T/C] NM_020546 ADCY2 Silent rs252546 5 7478914 [A/G] NM_020546 ADCY2 Silent rs252545 5 7479953 [T/C] NM_020546 ADCY2 Silent rs10512925 5 7487961 [A/G] NM_020546 ADCY2 Silent rs11948030 5 7493177 [T/C] NM_020546 ADCY2 Silent rs4333285 5 7497783 [A/G] NM_020546 ADCY2 Silent rs968119 5 7503123 [A/G] NM_020546 ADCY2 Silent rs7721013 5 7506433 [A/G] NM_020546 ADCY2 Silent rs7734525 5 7510019 [T/C] NM_020546 ADCY2 Silent rs1995276 5 7510391 [T/C] NM_020546 ADCY2 Silent rs4263480 5 7510936 [A/G] NM_020546 ADCY2 Silent rs7711777 5 7512421 [T/C] NM_020546 ADCY2 Silent rs10073047 5 7515170 [A/G] NM_020546 ADCY2 Silent rs16878728 5 7515565 [T/C] NM_020546 ADCY2 Silent rs17826546 5 7515682 [A/G] NM_020546 ADCY2 Silent rs17826588 5 7516555 [T/C] NM_020546 ADCY2 Silent rs10038196 5 7517418 [T/G] NM_020546 ADCY2 Silent rs10462842 5 7517897 [A/C] NM_020546 ADCY2 Silent rs10066518 5 7518855 [A/G] NM_020546 ADCY2 Silent rs16878741 5 7519387 [A/G] NM_020546 ADCY2 Silent rs6867567 5 7519762 [A/G] NM_020546 ADCY2 Silent rs3828628 5 7521083 [A/G] NM_020546 ADCY2 Silent rs7721273 5 7524548 [T/C] NM_020546 ADCY2 Silent rs13159560 5 7526262 [A/G] NM_020546 ADCY2 Silent rs2055388 5 7527521 [T/G] NM_020546 ADCY2 Silent rs7714110 5 7528287 [T/C] NM_020546 ADCY2 Silent rs4702473 5 7528558 [T/C] NM_020546 ADCY2 Silent rs10062110 5 7529177 [T/C] NM_020546 ADCY2 Silent rs6555474 5 7529813 [A/G] NM_020546 ADCY2 Silent rs17827324 5 7532066 [T/C] NM_020546 ADCY2 Silent rs4701786 5 7532455 [A/G] NM_020546 ADCY2 Silent rs1027579 5 7534221 [A/G] NM_020546 ADCY2 Silent rs9313195 5 7537575 [A/G] NM_020546 ADCY2 Silent rs1392481 5 7538237 [T/C] NM_020546 ADCY2 Silent rs10035541 5 7539712 [A/G] NM_020546 ADCY2 Silent rs980483 5 7541212 [T/C] NM_020546 ADCY2 Silent rs16878777 5 7543355 [A/G] NM_020546 ADCY2 Silent rs13436413 5 7546015 [A/G] NM_020546 ADCY2 Silent rs7720767 5 7546394 [T/C] NM_020546 ADCY2 Silent rs1004784 5 7548178 [T/C] NM_020546 ADCY2 Silent rs883535 5 7549448 [A/C] NM_020546 ADCY2 Silent rs12522444 5 7553501 [A/G] NM_020546 ADCY2 Silent rs9313198 5 7561187 [A/G] NM_020546 ADCY2 Silent rs10475378 5 7561901 [A/G] NM_020546 ADCY2 Silent rs7717535 5 7563591 [T/C] NM_020546 ADCY2 Silent rs4532331 5 7565773 [A/G] NM_020546 ADCY2 Silent rs10043053 5 7569099 [T/C] NM_020546 ADCY2 Silent rs10866584 5 7571456 [A/G] NM_020546 ADCY2 Silent rs6875695 5 7575713 [T/C] NM_020546 ADCY2 Silent rs4541631 5 7578342 [T/C] NM_020546 ADCY2 Silent rs6555477 5 7587939 [A/G] NM_020546 ADCY2 Silent rs2388875 5 7593892 [A/G] NM_020546 ADCY2 Silent rs13166852 5 7595762 [T/C] NM_020546 ADCY2 Silent rs16878811 5 7609916 [A/G] NM_020546 ADCY2 Silent rs10058810 5 7618656 [A/G] NM_020546 ADCY2 Silent rs1428530 5 7625795 [T/C] NM_020546 ADCY2 Silent rs1035905 5 7629191 [A/G] NM_020546 ADCY2 Silent rs2914290 5 7629756 [T/C] NM_020546 ADCY2 Silent rs7706191 5 7632077 [T/C] NM_020546 ADCY2 Silent rs10073795 5 7634665 [T/C] NM_020546 ADCY2 Silent rs2914294 5 7638234 [A/C] NM_020546 ADCY2 Silent rs12520264 5 7645474 [A/G] NM_020546 ADCY2 Silent rs4702484 5 7649860 [T/C] NM_020546 ADCY2 Silent rs2973319 5 7657882 [A/G] NM_020546 ADCY2 Silent rs877886 5 7659279 [T/C] NM_020546 ADCY2 Silent rs727432 5 7663078 [T/G] NM_020546 ADCY2 Silent rs4289537 5 7664530 [T/C] NM_020546 ADCY2 Silent rs7445043 5 7666786 [A/G] NM_020546 ADCY2 Silent rs10462643 5 7667153 [T/C] NM_020546 ADCY2 Silent rs9654458 5 7668026 [T/C] NM_020546 ADCY2 Silent rs10076838 5 7668246 [A/G] NM_020546 ADCY2 Silent rs2914300 5 7669054 [T/C] NM_020546 ADCY2 Silent rs6555483 5 7681207 [A/G] NM_020546 ADCY2 Silent rs734986 5 7684243 [A/G] NM_020546 ADCY2 Silent rs1025296 5 7685079 [A/G] NM_020546 ADCY2 Silent rs1025298 5 7685776 [A/C] NM_020546 ADCY2 Silent rs2914310 5 7686874 [T/G] NM_020546 ADCY2 Silent rs7714830 5 7690201 [A/G] NM_020546 ADCY2 Silent rs10079813 5 7690872 [A/G] NM_020546 ADCY2 EXON Synonymous_R263R rs11134251 5 7695845 [A/C] NM_020546 ADCY2 Silent rs11134252 5 7696028 [T/C] NM_020546 ADCY2 Silent rs4701790 5 7704187 [T/C] NM_020546 ADCY2 Silent rs11134253 5 7706053 [A/G] NM_020546 ADCY2 Silent rs6878196 5 7717396 [T/C] NM_020546 ADCY2 Silent rs12716194 5 7728767 [A/C] NM_020546 ADCY2 Silent rs12189243 5 7737474 [T/C] NM_020546 ADCY2 Silent rs7730589 5 7744625 [T/C] NM_020546 ADCY2 Silent rs4131923 5 7747639 [A/G] NM_020546 ADCY2 Silent rs12186377 5 7749240 [T/C] NM_020546 ADCY2 Silent rs10060054 5 7749260 [T/C] NM_020546 ADCY2 Silent rs4334848 5 7754231 [T/C] NM_020546 ADCY2 Silent rs11750832 5 7756170 [A/G] NM_020546 ADCY2 Silent rs3935156 5 7757812 [A/G] NM_020546 ADCY2 Silent rs11134261 5 7764530 [A/C] NM_020546 ADCY2 Silent rs10051908 5 7769905 [T/G] NM_020546 ADCY2 Silent rs7711377 5 7772199 [A/G] NM_020546 ADCY2 Silent rs12520791 5 7776646 [A/G] NM_020546 ADCY2 Silent rs4702493 5 7782238 [T/C] NM_020546 ADCY2 Silent rs11748102 5 7783259 [A/G] NM_020546 ADCY2 Silent rs13165346 5 7783858 [T/C] NM_020546 ADCY2 Silent rs1563912 5 7787698 [A/G] NM_020546 ADCY2 Silent rs3816620 5 7790217 [A/C] NM_020546 ADCY2 Silent rs326129 5 7791762 [T/C] NM_020546 ADCY2 Silent rs326132 5 7791998 [T/C] NM_020546 ADCY2 Silent rs16879109 5 7792917 [T/C] NM_020546 ADCY2 Silent rs4629562 5 7794326 [A/G] NM_020546 ADCY2 Silent rs1460970 5 7794738 [A/G] NM_020546 ADCY2 Silent rs6864771 5 7797291 [A/G] NM_020546 ADCY2 Silent rs9313203 5 7799073 [A/G] NM_020546 ADCY2 Silent rs13162758 5 7801608 [A/G] NM_020546 ADCY2 Silent rs2290910 5 7802363 [T/C] NM_020546 ADCY2 EXON Synonymous_C887C rs326153 5 7815809 [T/C] NM_020546 ADCY2 Silent rs326155 5 7816645 [A/G] NM_020546 ADCY2 Silent rs326158 5 7817398 [T/G] NM_020546 ADCY2 Silent rs326162 5 7819850 [A/C] NM_020546 ADCY2 Silent rs989634 5 7822918 [T/C] NM_020546 ADCY2 Silent rs326171 5 7826058 [A/G] NM_020546 ADCY2 Silent rs16879199 5 7826445 [T/C] NM_020546 ADCY2 Silent rs10059539 5 7828404 [T/C] NM_020546 ADCY2 EXON Silent rs326173 5 7828533 [A/C] NM_020546 ADCY2 EXON Silent rs326177 5 7830825 [A/G] NM_001089584 C5orf49 EXON Silent rs2287778 5 7831013 [T/C] NM_001089584 C5orf49 EXON Silent rs3797192 5 7831806 [T/C] NM_001089584 C5orf49 EXON Silent rs11954873 5 7832119 [T/C] NM_001089584 C5orf49 EXON Synonymous_V96V rs1993716 5 7832387 [A/C] NM_001089584 C5orf49 Silent rs72001 5 7837861 [A/C] NM_001089584 C5orf49 Silent rs89599 5 7838085 [T/C] NM_001089584 C5orf49 Silent rs729126 5 7838364 [T/C] NM_001089584 C5orf49 Silent rs16879218 5 7839688 [A/G] NM_001089584 C5orf49 Silent rs326193 5 7843211 [T/C] NM_001089584 C5orf49 Silent rs326205 5 7852282 [A/G] rs4702506 5 7854289 [T/C] rs17243407 5 7858121 [A/G] rs1046014 5 7859434 [T/C] NM_024091,NR_036553,NR_073608 FASTKD3,FASTKD3,FASTKD3 EXON Silent,Silent,Silent rs1046012 5 7859523 [A/G] NM_024091,NR_036553,NR_073608 FASTKD3,FASTKD3,FASTKD3 EXON Silent,Silent,Silent rs16879236 5 7859702 [T/G] NM_024091,NR_036553,NR_073608 FASTKD3,FASTKD3,FASTKD3 Silent,Silent,Silent rs162024 5 7860404 [T/G] NM_024091,NR_036553,NR_073608 FASTKD3,FASTKD3,FASTKD3 Silent,Silent,Silent rs162027 5 7861638 [T/C] NM_024091,NR_036553,NR_073608 FASTKD3,FASTKD3,FASTKD3 Silent,Silent,Silent rs2307116 5 7861985 [A/G] NM_024091,NR_036553,NR_073608 FASTKD3,FASTKD3,FASTKD3 Silent,Silent,Silent rs3733784 5 7862926 [T/C] NM_024091,NR_036553,NR_073608 FASTKD3,FASTKD3,FASTKD3 Silent,Silent,Silent rs16879258 5 7865891 [A/C] NM_024091,NR_036553,NR_073608 FASTKD3,FASTKD3,FASTKD3 Silent,Silent,Silent rs2966952 5 7868030 [T/C] NM_024091,NR_036553,NR_073608 FASTKD3,FASTKD3,FASTKD3 EXON Missense_K56R,Silent,Silent rs1801394 5 7870973 [A/G] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR EXON Missense_I22M,Silent,Silent,Silent,Silent,Missense_I22M,Missense_I22M,Missense_I22M,Silent,Silent,Silent,Silent,Missense_I22M,Silent,Silent,Silent,Silent,Silent,Silent rs7725672 5 7871490 [A/G] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13181011 5 7874424 [T/C] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7730643 5 7875963 [A/G] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs326121 5 7876288 [T/C] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3776467 5 7876315 [A/G] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs326123 5 7876861 [A/G] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7703033 5 7879950 [A/G] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6555501 5 7879983 [T/C] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs162031 5 7880287 [T/C] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10040859 5 7882916 [A/G] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs161871 5 7884389 [A/G] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3776463 5 7885227 [A/G] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16879305 5 7885526 [T/C] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs162036 5 7885959 [A/G] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR EXON Missense_K350R,Silent,Silent,Silent,Silent,Missense_K350R,Missense_K350R,Missense_K350R,Silent,Silent,Silent,Silent,Missense_K350R,Silent,Silent,Silent,Silent,Silent,Silent rs162040 5 7887478 [A/C] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2287780 5 7889304 [T/C] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR EXON Missense_R415C,Silent,Silent,Silent,Silent,Missense_R415C,Missense_R415C,Missense_R415C,Silent,Silent,Silent,Silent,Missense_R415C,Silent,Silent,Silent,Silent,Silent,Silent rs162049 5 7893121 [A/G] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3776455 5 7896511 [T/C] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10380 5 7897191 [T/C] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR EXON Missense_H595Y,Silent,Silent,Silent,Silent,Missense_H595Y,Missense_H595Y,Missense_H595Y,Silent,Silent,Silent,Silent,Missense_H595Y,Silent,Silent,Silent,Silent,Silent,Silent rs12347 5 7897283 [A/G] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR EXON Synonymous_V625V,Silent,Silent,Silent,Silent,Synonymous_V625V,Synonymous_V625V,Synonymous_V625V,Silent,Silent,Silent,Silent,Synonymous_V625V,Silent,Silent,Silent,Silent,Silent,Silent rs1802059 5 7897319 [A/G] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR EXON Synonymous_A637A,Silent,Silent,Silent,Silent,Synonymous_A637A,Synonymous_A637A,Synonymous_A637A,Silent,Silent,Silent,Silent,Synonymous_A637A,Silent,Silent,Silent,Silent,Silent,Silent rs9332 5 7900712 [A/G] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10520873 5 7901230 [T/C] NM_002454,NR_134481,NR_134480,NR_134482,NR_157170,NM_001364441,NM_001364440,NM_001364442,NR_157169,NR_157168,NR_157175,NR_157177,NM_024010,NR_157173,NR_157174,NR_157172,NR_157176,NR_157178,NR_157171 MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR,MTRR EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11951657 5 7908900 [T/C] rs162270 5 7909907 [A/C] rs162271 5 7911043 [T/C] rs16879410 5 7913668 [T/A] rs11743287 5 7920843 [T/G] rs327575 5 7923683 [T/C] rs1384230 5 7927160 [A/G] rs16879452 5 7928158 [A/G] rs2640660 5 7930701 [A/G] rs10440693 5 7930866 [A/G] rs2640658 5 7933629 [T/G] rs2170498 5 7936153 [A/G] rs10512934 5 7936287 [T/C] rs97713 5 7941757 [A/G] rs329852 5 7943796 [A/C] rs162446 5 7944537 [A/G] rs1471621 5 7946262 [A/G] rs1564592 5 7950600 [A/G] rs7703389 5 7952282 [T/C] rs1542781 5 7952536 [A/G] rs11744470 5 7952808 [A/G] rs329831 5 7953909 [T/C] rs7719963 5 7955677 [T/G] rs331412 5 7957409 [T/C] rs331413 5 7958031 [A/G] rs9313211 5 7967228 [A/G] rs7719216 5 7970898 [A/G] rs11742403 5 7980403 [A/G] rs13170463 5 7983252 [A/G] rs11748296 5 7983691 [A/G] rs1482277 5 7984232 [T/C] rs1503322 5 7984374 [A/G] rs2654520 5 7985855 [T/C] rs11134268 5 7986155 [A/G] rs1503317 5 7992135 [T/C] rs11134269 5 7994914 [T/C] rs6866169 5 7995509 [T/C] rs7702491 5 7997545 [A/G] rs4701802 5 8004748 [T/G] rs2966953 5 8006656 [A/G] rs2123637 5 8013445 [T/C] rs12520611 5 8015429 [A/G] rs12523589 5 8027851 [T/G] rs2938240 5 8029265 [A/G] rs13187219 5 8031332 [T/C] rs7711682 5 8034275 [T/G] rs13190277 5 8035272 [A/G] rs1377489 5 8036385 [T/C] rs1377490 5 8036594 [A/G] rs6871063 5 8047445 [T/C] rs876712 5 8047543 [A/C] rs6896973 5 8049644 [A/G] rs13157813 5 8051151 [T/C] rs13167372 5 8052369 [A/C] rs2924471 5 8055261 [T/C] rs11959696 5 8055319 [T/C] rs3943482 5 8055558 [T/C] rs2938245 5 8055690 [A/G] rs1530963 5 8059524 [A/C] rs16879792 5 8060320 [A/C] rs964017 5 8062181 [T/G] rs10475403 5 8062594 [T/C] rs6886541 5 8062672 [T/C] rs6860289 5 8062748 [A/G] rs11744506 5 8067973 [T/G] rs2961986 5 8073071 [A/G] rs1453363 5 8073378 [A/G] rs4702523 5 8073928 [A/G] rs10043550 5 8074665 [A/G] rs2924466 5 8077509 [A/G] rs11134282 5 8083187 [A/G] rs4702526 5 8090525 [T/C] rs13190226 5 8097721 [A/G] rs17250829 5 8098291 [A/C] rs7716010 5 8100893 [A/G] rs7725153 5 8105591 [A/G] rs12658423 5 8110170 [T/G] rs6860481 5 8113536 [A/C] rs4702528 5 8115307 [T/C] rs1506105 5 8121656 [T/C] rs12521059 5 8123555 [T/C] rs10057537 5 8123994 [A/G] rs13157534 5 8130010 [A/G] rs6555523 5 8130362 [A/G] rs13172069 5 8131880 [T/C] rs2602524 5 8132978 [T/G] rs2658161 5 8133694 [T/C] rs6876162 5 8135922 [A/G] rs1506127 5 8140979 [T/G] rs13171587 5 8145014 [A/C] rs336138 5 8146371 [T/G] rs336164 5 8149540 [T/C] rs7723051 5 8151217 [A/G] rs10512943 5 8151979 [T/G] rs16879963 5 8153024 [T/C] rs10079013 5 8157307 [T/C] rs170936 5 8158804 [T/C] rs6555524 5 8165111 [A/G] rs163115 5 8172103 [T/C] rs336178 5 8173436 [T/G] rs13170530 5 8174188 [T/C] rs901893 5 8175049 [T/C] rs730757 5 8175968 [A/G] rs906091 5 8179705 [A/G] rs7701145 5 8180407 [A/G] rs1823809 5 8188341 [T/G] rs7702422 5 8188395 [T/C] rs12521485 5 8189299 [A/C] rs7707765 5 8189392 [T/C] rs10780108 5 8202659 [A/C] rs7702825 5 8205612 [A/G] rs6867552 5 8211892 [T/C] rs16880084 5 8212566 [A/G] rs11738766 5 8214282 [A/G] rs6892570 5 8226339 [T/G] rs16880098 5 8226502 [T/C] rs6875114 5 8228409 [T/C] rs6875427 5 8228590 [T/C] rs10512947 5 8231744 [T/C] rs10512948 5 8233351 [T/C] rs10462854 5 8239357 [A/G] rs1857863 5 8240153 [T/C] rs16880191 5 8241427 [T/C] rs4639181 5 8243414 [T/C] rs1906573 5 8244864 [A/G] rs2171567 5 8258881 [T/C] rs6880502 5 8259322 [A/C] rs12514960 5 8260550 [T/C] rs9654459 5 8260630 [T/C] rs4235590 5 8261891 [T/G] rs7444241 5 8265008 [T/G] rs906087 5 8270536 [T/C] rs11948974 5 8276583 [A/G] rs4640759 5 8278166 [A/C] rs4590157 5 8278270 [A/G] rs1506114 5 8279902 [T/C] rs6887466 5 8291230 [T/C] rs16880316 5 8292668 [A/G] rs10056042 5 8295533 [T/C] rs11134307 5 8302197 [A/G] rs6555540 5 8303435 [T/C] rs10512951 5 8303911 [T/C] rs12653839 5 8317136 [T/C] rs2129949 5 8319421 [T/C] rs12109465 5 8321133 [A/C] rs17211011 5 8322525 [T/C] rs4302555 5 8323964 [A/C] rs4492083 5 8325714 [T/C] rs16880382 5 8328125 [T/G] rs925203 5 8328783 [T/G] rs7724111 5 8330346 [T/C] rs7710227 5 8330492 [T/C] rs6895861 5 8332937 [A/G] rs2962126 5 8333425 [A/G] rs2136170 5 8337146 [T/C] NR_039984 LINC02226 Silent rs2964129 5 8349231 [T/C] NR_039984 LINC02226 Silent rs2940556 5 8349784 [A/C] NR_039984 LINC02226 Silent rs170991 5 8371633 [A/G] NR_039984 LINC02226 Silent rs340677 5 8384247 [A/G] NR_039984 LINC02226 Silent rs1448235 5 8384936 [A/G] NR_039984 LINC02226 Silent rs340680 5 8385180 [A/G] NR_039984 LINC02226 Silent rs371741 5 8392393 [A/G] NR_039984 LINC02226 Silent rs12653627 5 8393159 [A/G] NR_039984 LINC02226 Silent rs16880510 5 8396885 [A/C] NR_039984 LINC02226 Silent rs11743533 5 8404594 [A/C] NR_039984 LINC02226 Silent rs11743538 5 8404645 [T/C] NR_039984 LINC02226 Silent rs17279186 5 8407305 [T/C] NR_039984 LINC02226 Silent rs2457108 5 8413356 [T/C] NR_039984 LINC02226 Silent rs448636 5 8417115 [T/G] NR_039984 LINC02226 Silent rs340700 5 8423142 [T/G] NR_039984 LINC02226 Silent rs4702551 5 8424283 [A/G] NR_039984 LINC02226 Silent rs7717779 5 8429773 [T/C] NR_039984 LINC02226 Silent rs340671 5 8436209 [A/G] NR_039984 LINC02226 Silent rs10080066 5 8438752 [T/C] NR_039984 LINC02226 Silent rs12187557 5 8439670 [T/C] NR_039984 LINC02226 Silent rs6555545 5 8440728 [A/G] NR_039984 LINC02226 Silent rs16880614 5 8442087 [T/C] NR_039984 LINC02226 Silent rs6555548 5 8446336 [A/G] NR_039984 LINC02226 Silent rs2166870 5 8447297 [T/C] NR_039984 LINC02226 Silent rs10475431 5 8447327 [T/G] NR_039984 LINC02226 Silent rs6860832 5 8451757 [A/G] NR_039984 LINC02226 Silent rs16880638 5 8456731 [A/G] NR_039984 LINC02226 Silent rs9313239 5 8459533 [T/G] NR_039989 MIR4458HG Silent rs16880661 5 8465020 [T/C] rs11954087 5 8466223 [T/C] rs341893 5 8467900 [A/C] rs168188 5 8477908 [A/G] rs12657402 5 8484044 [T/C] rs438225 5 8489624 [T/C] rs13177016 5 8493663 [T/C] rs173134 5 8494868 [A/G] rs11750041 5 8498184 [T/C] rs1553550 5 8499805 [A/G] rs10058288 5 8502392 [T/C] rs16880714 5 8504245 [T/G] rs6892211 5 8504567 [T/C] rs17216061 5 8518835 [T/G] rs13436318 5 8519979 [A/C] rs415234 5 8522021 [A/G] rs11948129 5 8522181 [A/G] rs1002548 5 8523982 [A/G] rs444121 5 8527859 [T/C] rs11949420 5 8528431 [A/G] rs402359 5 8529586 [T/G] rs1613720 5 8533359 [A/G] rs10059676 5 8534327 [A/G] rs1700569 5 8538868 [A/G] rs1505016 5 8540496 [A/G] rs1666797 5 8540538 [T/C] rs422977 5 8540995 [A/G] rs10474839 5 8542856 [T/G] rs423297 5 8543442 [T/C] rs424158 5 8543827 [T/C] rs418262 5 8544489 [A/G] rs9313241 5 8547779 [T/C] rs9313243 5 8549411 [T/C] rs10056790 5 8554863 [A/G] rs12653550 5 8554971 [A/G] rs6555554 5 8558215 [A/G] rs13161601 5 8558468 [T/G] rs756757 5 8562829 [A/G] rs1157652 5 8565638 [T/C] rs12515836 5 8569124 [A/G] rs11134316 5 8572050 [T/C] rs16880863 5 8573076 [A/G] rs2106316 5 8575930 [A/G] rs10071703 5 8577515 [A/G] rs6867425 5 8578343 [T/C] rs11743542 5 8580301 [T/C] rs768900 5 8583411 [T/C] rs4702561 5 8584086 [T/C] rs199169 5 8586300 [T/C] rs12522315 5 8586827 [A/C] rs1468112 5 8588451 [T/C] rs11952768 5 8594764 [T/C] rs1501340 5 8595305 [A/G] rs1604318 5 8597846 [T/C] rs7709563 5 8603334 [T/C] rs16880891 5 8610332 [A/G] rs1354096 5 8613262 [T/G] rs199175 5 8625584 [T/C] rs1501347 5 8628753 [A/G] rs10040826 5 8634454 [T/G] rs199990 5 8641457 [A/G] rs10512974 5 8642182 [A/G] rs200121 5 8645775 [A/C] rs12519783 5 8650225 [A/G] rs200116 5 8650331 [T/C] rs199195 5 8655624 [A/G] rs200104 5 8655966 [T/C] rs11949296 5 8656946 [A/G] rs9313251 5 8657664 [T/G] rs200094 5 8661907 [T/C] rs200086 5 8663983 [A/G] rs200071 5 8670219 [A/G] rs999419 5 8671855 [T/G] rs13170506 5 8672942 [T/C] rs199187 5 8676369 [A/G] rs200059 5 8680327 [T/C] rs11134323 5 8691906 [A/G] rs200027 5 8692312 [T/C] rs200016 5 8693465 [A/G] rs200013 5 8694523 [T/C] rs200008 5 8697444 [T/C] rs17289138 5 8703085 [T/G] rs13171847 5 8705837 [T/C] rs16881136 5 8708019 [T/G] rs16881143 5 8715360 [T/C] rs1024393 5 8718172 [A/G] rs7706072 5 8726235 [T/C] rs7727009 5 8728874 [A/G] rs1501336 5 8730120 [T/C] rs6864374 5 8740641 [T/C] rs156466 5 8743390 [A/G] rs2388355 5 8744557 [A/G] rs156453 5 8752756 [T/C] rs156452 5 8753733 [A/C] rs999428 5 8769738 [T/C] rs999426 5 8770185 [T/C] rs2904956 5 8771494 [T/C] rs1505028 5 8777256 [A/G] rs12655943 5 8778454 [A/G] rs2963391 5 8783755 [A/C] rs877813 5 8786179 [A/G] rs7710497 5 8786798 [T/C] rs10491224 5 8789479 [A/G] rs3111121 5 8790996 [A/G] rs2938816 5 8791745 [A/G] rs992149 5 8794278 [A/G] rs10035283 5 8794957 [T/C] rs7730627 5 8798487 [A/G] rs4701822 5 8808777 [A/G] rs1505023 5 8814924 [A/G] rs1505022 5 8824158 [T/C] rs995555 5 8828135 [A/G] rs10051161 5 8830876 [T/C] rs2963416 5 8836536 [T/C] rs2904930 5 8836613 [T/C] rs1394650 5 8837390 [A/G] rs756666 5 8844967 [T/C] NR_109932 LINC02199 Silent rs4280839 5 8857503 [A/G] NR_109932 LINC02199 Silent rs11134335 5 8860434 [A/G] NR_109932 LINC02199 Silent rs16881512 5 8862669 [A/G] NR_109932 LINC02199 Silent rs10512985 5 8867419 [A/G] NR_109932 LINC02199 Silent rs7702790 5 8870267 [T/C] NR_109932 LINC02199 Silent rs10053782 5 8871850 [A/C] NR_109932 LINC02199 Silent rs17225452 5 8873310 [T/G] NR_109932 LINC02199 Silent rs2963328 5 8891253 [A/G] rs11948993 5 8891510 [T/C] rs10447192 5 8896731 [T/C] rs16881623 5 8900992 [A/G] rs16881630 5 8901512 [A/C] rs2962685 5 8901696 [T/G] rs16881639 5 8903540 [A/G] rs2962683 5 8903736 [T/G] rs10067616 5 8904380 [A/G] rs4702597 5 8906784 [A/C] rs2963342 5 8908886 [T/G] rs2962669 5 8919975 [A/G] rs2962663 5 8923420 [A/G] rs7710498 5 8924466 [A/C] rs6555577 5 8924770 [A/G] rs2963327 5 8934159 [A/G] rs2963337 5 8935632 [T/G] rs10053481 5 8936345 [T/C] rs4583857 5 8941558 [A/G] rs10041919 5 8950940 [A/G] rs6874770 5 8955823 [T/G] rs9313264 5 8961561 [T/C] rs6889183 5 8968532 [A/C] rs7728475 5 8969172 [A/G] rs13359924 5 8976107 [T/C] rs1947584 5 8980099 [T/C] rs11134338 5 8983721 [A/G] rs1350379 5 8997962 [T/C] rs2962720 5 9009675 [T/C] rs16881838 5 9012115 [T/C] rs17235037 5 9013608 [T/C] rs985722 5 9013766 [T/C] rs1598826 5 9021310 [T/C] rs13152876 5 9026797 [A/G] rs16881875 5 9038043 [A/G] NM_003966 SEMA5A EXON Silent rs17235366 5 9039288 [T/C] NM_003966 SEMA5A EXON Silent rs786840 5 9041935 [A/G] NM_003966 SEMA5A EXON Silent rs11741186 5 9044674 [A/G] NM_003966 SEMA5A EXON Synonymous_I972I rs257098 5 9050410 [T/C] NM_003966 SEMA5A Silent rs257095 5 9053945 [T/C] NM_003966,NR_039779 SEMA5A,MIR4636 EXON Silent,Silent rs11953813 5 9060435 [T/C] NM_003966 SEMA5A Silent rs16881901 5 9062943 [A/G] NM_003966 SEMA5A Silent rs786847 5 9066464 [A/G] NM_003966 SEMA5A Silent rs786846 5 9066802 [A/G] NM_003966 SEMA5A Silent rs12716205 5 9078628 [T/C] NM_003966 SEMA5A Silent rs1013720 5 9087921 [T/C] NM_003966 SEMA5A Silent rs253634 5 9091164 [A/G] NM_003966 SEMA5A Silent rs253635 5 9092642 [T/G] NM_003966 SEMA5A Silent rs17309469 5 9100211 [A/G] NM_003966 SEMA5A Silent rs2456237 5 9105283 [T/C] NM_003966 SEMA5A Silent rs7731508 5 9107887 [T/C] NM_003966 SEMA5A Silent rs2657031 5 9112040 [T/C] NM_003966 SEMA5A Silent rs190423 5 9121472 [T/C] NM_003966 SEMA5A Silent rs3777253 5 9121591 [T/G] NM_003966 SEMA5A Silent rs6894626 5 9122926 [T/C] NM_003966 SEMA5A EXON Synonymous_G541G rs2619913 5 9128445 [T/C] NM_003966 SEMA5A Silent rs2657033 5 9130044 [A/G] NM_003966 SEMA5A Silent rs1479647 5 9130780 [T/C] NM_003966 SEMA5A Silent rs10057636 5 9137550 [T/C] NM_003966 SEMA5A Silent rs6555593 5 9140514 [A/G] NM_003966 SEMA5A Silent rs983856 5 9140848 [A/G] NM_003966 SEMA5A Silent rs13155922 5 9142253 [T/C] NM_003966 SEMA5A Silent rs12189232 5 9148278 [A/G] NM_003966 SEMA5A Silent rs1904454 5 9149422 [A/G] NM_003966 SEMA5A Silent rs7723025 5 9151237 [A/C] NM_003966 SEMA5A Silent rs899576 5 9155420 [A/C] NM_003966 SEMA5A Silent rs886511 5 9155728 [A/C] NM_003966 SEMA5A Silent rs886508 5 9156101 [T/C] NM_003966 SEMA5A Silent rs1806138 5 9157454 [A/G] NM_003966 SEMA5A Silent rs2526121 5 9158742 [A/G] NM_003966 SEMA5A Silent rs2256569 5 9160380 [T/C] NM_003966 SEMA5A Silent rs3846574 5 9161412 [A/G] NM_003966 SEMA5A Silent rs3777275 5 9169940 [T/C] NM_003966 SEMA5A Silent rs3797928 5 9170323 [T/C] NM_003966 SEMA5A Silent rs40718 5 9173880 [A/G] NM_003966 SEMA5A Silent rs3822773 5 9174381 [T/G] NM_003966 SEMA5A Silent rs10044766 5 9176431 [T/C] NM_003966 SEMA5A Silent rs3777281 5 9177932 [T/C] NM_003966 SEMA5A Silent rs10513010 5 9182376 [A/G] NM_003966 SEMA5A Silent rs13171149 5 9182717 [T/C] NM_003966 SEMA5A Silent rs13436248 5 9184632 [A/G] NM_003966 SEMA5A Silent rs42353 5 9187035 [T/C] NM_003966 SEMA5A Silent rs40703 5 9189454 [T/C] NM_003966 SEMA5A Silent rs3797937 5 9191362 [A/G] NM_003966 SEMA5A Silent rs1806125 5 9192881 [A/C] NM_003966 SEMA5A Silent rs1806123 5 9193406 [T/C] NM_003966 SEMA5A Silent rs1806121 5 9194521 [T/C] NM_003966 SEMA5A Silent rs40693 5 9194611 [T/C] NM_003966 SEMA5A Silent rs40687 5 9195233 [A/G] NM_003966 SEMA5A Silent rs1806085 5 9197607 [T/C] NM_003966 SEMA5A Silent rs1806112 5 9200137 [A/G] NM_003966 SEMA5A Silent rs40680 5 9203989 [A/G] NM_003966 SEMA5A Silent rs1479651 5 9204238 [A/G] NM_003966 SEMA5A Silent rs1806067 5 9205587 [T/C] NM_003966 SEMA5A Silent rs1805964 5 9209831 [T/G] NM_003966 SEMA5A Silent rs1805962 5 9215068 [A/G] NM_003966 SEMA5A Silent rs40669 5 9222811 [A/G] NM_003966 SEMA5A Silent rs17254539 5 9225088 [T/C] NM_003966 SEMA5A Silent rs40666 5 9228171 [T/G] NM_003966 SEMA5A Silent rs40665 5 9228283 [T/C] NM_003966 SEMA5A Silent rs1806018 5 9230988 [A/G] NM_003966 SEMA5A Silent rs42495 5 9231066 [T/G] NM_003966 SEMA5A Silent rs1805958 5 9234541 [A/G] NM_003966 SEMA5A Silent rs1805957 5 9234736 [T/G] NM_003966 SEMA5A Silent rs12716206 5 9249231 [T/C] NM_003966 SEMA5A Silent rs3912190 5 9249806 [A/G] NM_003966 SEMA5A Silent rs1805990 5 9252731 [A/G] NM_003966 SEMA5A Silent rs40713 5 9254909 [T/C] NM_003966 SEMA5A Silent rs3797968 5 9263933 [T/C] NM_003966 SEMA5A Silent rs40708 5 9264682 [T/C] NM_003966 SEMA5A Silent rs1805939 5 9266755 [A/G] NM_003966 SEMA5A Silent rs1805918 5 9268737 [T/C] NM_003966 SEMA5A Silent rs1034743 5 9269658 [T/C] NM_003966 SEMA5A Silent rs6873909 5 9287073 [A/G] NM_003966 SEMA5A Silent rs4540155 5 9292221 [A/G] NM_003966 SEMA5A Silent rs3822787 5 9293213 [A/G] NM_003966 SEMA5A Silent rs3777306 5 9295681 [A/C] NM_003966 SEMA5A Silent rs3734152 5 9299338 [T/G] NM_003966 SEMA5A Silent rs3777323 5 9313958 [A/G] NM_003966 SEMA5A Silent rs805145 5 9315454 [T/G] NM_003966 SEMA5A Silent rs12655979 5 9317252 [T/C] NM_003966 SEMA5A Silent rs9313273 5 9331477 [A/G] NM_003966 SEMA5A Silent rs916990 5 9331490 [A/G] NM_003966 SEMA5A Silent rs6896702 5 9331848 [T/C] NM_003966 SEMA5A Silent rs7702187 5 9332281 [T/A] NM_003966 SEMA5A Silent rs1918779 5 9332459 [T/C] NM_003966 SEMA5A Silent rs1205726 5 9343414 [T/C] NM_003966 SEMA5A Silent rs1205725 5 9343913 [T/C] NM_003966 SEMA5A Silent rs1024487 5 9357007 [T/C] NM_003966 SEMA5A Silent rs2463505 5 9357056 [T/C] NM_003966 SEMA5A Silent rs1205718 5 9357103 [T/C] NM_003966 SEMA5A Silent rs2463506 5 9357942 [A/G] NM_003966 SEMA5A Silent rs10491235 5 9358953 [T/C] NM_003966 SEMA5A Silent rs17196621 5 9359420 [A/C] NM_003966 SEMA5A Silent rs3798000 5 9362804 [T/C] NM_003966 SEMA5A Silent rs3798003 5 9364904 [T/C] NM_003966 SEMA5A Silent rs40654 5 9371411 [A/G] NM_003966 SEMA5A Silent rs42192 5 9373448 [T/C] NM_003966 SEMA5A Silent rs28263 5 9373641 [T/G] NM_003966 SEMA5A Silent rs194261 5 9376118 [T/C] NM_003966 SEMA5A Silent rs194265 5 9377777 [T/G] NM_003966 SEMA5A Silent rs1805243 5 9380110 [T/C] NM_003966 SEMA5A EXON Silent rs805153 5 9380932 [A/G] NM_003966 SEMA5A Silent rs1805927 5 9382861 [A/G] NM_003966 SEMA5A Silent rs16882600 5 9386310 [T/C] NM_003966 SEMA5A Silent rs42196 5 9386591 [T/G] NM_003966 SEMA5A Silent rs13153629 5 9389867 [T/C] NM_003966 SEMA5A Silent rs390322 5 9390217 [A/G] NM_003966 SEMA5A Silent rs1877459 5 9391753 [T/C] NM_003966 SEMA5A Silent rs788469 5 9397850 [A/G] NM_003966 SEMA5A Silent rs410741 5 9401606 [T/G] NM_003966 SEMA5A Silent rs447322 5 9402037 [A/C] NM_003966 SEMA5A Silent rs10214283 5 9403198 [A/G] NM_003966 SEMA5A Silent rs17323208 5 9403456 [T/C] NM_003966 SEMA5A Silent rs2463503 5 9409056 [T/C] NM_003966 SEMA5A Silent rs6879538 5 9411249 [T/C] NM_003966 SEMA5A Silent rs425620 5 9413362 [A/G] NM_003966 SEMA5A Silent rs4701846 5 9417622 [T/C] NM_003966 SEMA5A Silent rs666617 5 9420374 [T/C] NM_003966 SEMA5A Silent rs406898 5 9420645 [A/C] NM_003966 SEMA5A Silent rs11134354 5 9421794 [A/G] NM_003966 SEMA5A Silent rs17258120 5 9423834 [T/G] NM_003966 SEMA5A Silent rs7724626 5 9424801 [T/G] NM_003966 SEMA5A Silent rs3846586 5 9425173 [A/G] NM_003966 SEMA5A Silent rs268486 5 9426734 [T/C] NM_003966 SEMA5A Silent rs11951666 5 9429290 [T/G] NM_003966 SEMA5A Silent rs268482 5 9435478 [A/G] NM_003966 SEMA5A Silent rs3798009 5 9438120 [A/C] NM_003966 SEMA5A Silent rs3822794 5 9438454 [A/G] NM_003966 SEMA5A Silent rs3798012 5 9438493 [A/G] NM_003966 SEMA5A Silent rs1858428 5 9438538 [A/G] NM_003966 SEMA5A Silent rs268534 5 9438778 [T/C] NM_003966 SEMA5A Silent rs3756725 5 9439642 [A/G] NM_003966 SEMA5A Silent rs1512509 5 9440094 [T/C] NM_003966 SEMA5A Silent rs268532 5 9441720 [A/G] NM_003966 SEMA5A Silent rs2135072 5 9442007 [T/C] NM_003966 SEMA5A Silent rs268529 5 9442994 [A/C] NM_003966 SEMA5A Silent rs707637 5 9445434 [T/C] NM_003966 SEMA5A Silent rs1512508 5 9445461 [T/C] NM_003966 SEMA5A Silent rs268525 5 9447501 [T/C] NM_003966 SEMA5A Silent rs440396 5 9450621 [T/C] NM_003966 SEMA5A Silent rs3822799 5 9450746 [T/C] NM_003966 SEMA5A Silent rs436243 5 9453089 [A/C] NM_003966 SEMA5A Silent rs3756727 5 9454208 [A/C] NM_003966 SEMA5A Silent rs268542 5 9456166 [A/C] NM_003966 SEMA5A Silent rs3798031 5 9457243 [T/C] NM_003966 SEMA5A Silent rs3822803 5 9458879 [A/C] NM_003966 SEMA5A Silent rs397287 5 9463291 [A/C] NM_003966 SEMA5A Silent rs16882852 5 9466215 [A/G] NM_003966 SEMA5A Silent rs16882862 5 9471319 [T/C] NM_003966 SEMA5A Silent rs171992 5 9473948 [T/C] NM_003966 SEMA5A Silent rs433755 5 9474946 [A/C] NM_003966 SEMA5A Silent rs391353 5 9482151 [A/G] NM_003966 SEMA5A Silent rs418446 5 9483209 [A/G] NM_003966 SEMA5A Silent rs268517 5 9485396 [T/C] NM_003966 SEMA5A Silent rs950050 5 9488689 [A/G] NM_003966 SEMA5A Silent rs12657696 5 9495607 [T/C] NM_003966 SEMA5A Silent rs369459 5 9507624 [T/C] NM_003966 SEMA5A Silent rs442173 5 9509018 [A/G] NM_003966 SEMA5A Silent rs11959773 5 9509811 [A/C] NM_003966 SEMA5A Silent rs268558 5 9519853 [A/G] NM_003966 SEMA5A Silent rs465107 5 9522303 [A/G] NM_003966 SEMA5A Silent rs3798068 5 9523375 [T/C] NM_003966 SEMA5A Silent rs465991 5 9529244 [T/C] NM_003966 SEMA5A Silent rs462473 5 9529809 [T/G] NM_003966 SEMA5A Silent rs268550 5 9533854 [T/C] NM_003966 SEMA5A Silent rs268551 5 9534206 [T/G] NM_003966 SEMA5A Silent rs3756737 5 9534392 [T/C] NM_003966 SEMA5A Silent rs3798083 5 9536983 [A/G] NM_003966 SEMA5A Silent rs6881628 5 9539540 [T/G] NM_003966 SEMA5A Silent rs3798089 5 9541289 [A/G] NM_003966 SEMA5A Silent rs16883082 5 9541480 [T/C] NM_003966 SEMA5A Silent rs3798097 5 9542529 [T/C] NM_003966 SEMA5A Silent rs1651283 5 9547129 [A/G] NR_045196 SNHG18 Silent rs1398337 5 9548098 [T/C] NR_045196 SNHG18 Silent rs17329485 5 9549386 [T/C] NR_045196 SNHG18 Silent rs12186736 5 9549755 [A/G] NR_045196 SNHG18 EXON Silent rs930076 5 9550642 [T/C] rs16883128 5 9550770 [A/G] rs17329702 5 9551091 [T/C] rs16883129 5 9551198 [T/G] rs978896 5 9551296 [A/G] rs218057 5 9558232 [T/C] rs150633 5 9559903 [T/G] rs150631 5 9560249 [T/C] rs1508797 5 9562434 [T/C] rs1508796 5 9562669 [A/G] rs7728549 5 9565826 [A/G] rs1508801 5 9568765 [A/G] rs218041 5 9575041 [T/C] rs218053 5 9578794 [A/G] rs218052 5 9580273 [A/C] rs6895891 5 9589444 [T/C] rs41496 5 9592694 [T/C] rs6870771 5 9598097 [T/G] rs6897403 5 9598383 [A/G] rs218049 5 9602682 [T/C] rs390 5 9604363 [A/G] rs389 5 9604420 [A/G] rs400 5 9606057 [T/C] rs3846591 5 9606166 [T/C] rs3846595 5 9606663 [A/G] rs6897599 5 9607318 [A/C] rs10474846 5 9608903 [A/G] rs17265148 5 9609808 [T/G] rs6874254 5 9610282 [T/C] rs218036 5 9616496 [A/G] rs41457 5 9617512 [T/C] rs395 5 9617945 [T/C] rs41461 5 9619905 [T/C] rs41463 5 9621540 [A/G] rs2234235 5 9629295 [A/G] NM_019599 TAS2R1 EXON Synonymous_L284L rs2234233 5 9629529 [A/G] NM_019599 TAS2R1 EXON Missense_R206W rs2234232 5 9629723 [T/C] NM_019599 TAS2R1 EXON Missense_C141Y rs41469 5 9629813 [T/C] NM_019599 TAS2R1 EXON Missense_R111H rs3213627 5 9641628 [A/G] NR_027112 LINC02112 Silent rs17272325 5 9648873 [T/C] NR_027112 LINC02112 Silent rs27841 5 9658661 [T/C] NR_027112 LINC02112 Silent rs27843 5 9659384 [T/C] NR_027112 LINC02112 Silent rs1393232 5 9661352 [A/G] NR_027112 LINC02112 Silent rs28800 5 9666545 [A/G] NR_027112 LINC02112 Silent rs10513029 5 9667062 [T/C] NR_027112 LINC02112 Silent rs1604463 5 9677855 [T/C] NR_027112 LINC02112 Silent rs428378 5 9679139 [A/C] NR_027112 LINC02112 Silent rs12109904 5 9681798 [T/C] NR_027112 LINC02112 Silent rs194070 5 9684672 [T/C] NR_027112 LINC02112 Silent rs28738 5 9688551 [T/C] NR_027112 LINC02112 Silent rs10039101 5 9689026 [T/G] NR_027112 LINC02112 Silent rs42372 5 9690464 [T/C] NR_027112 LINC02112 Silent rs734618 5 9692938 [A/G] NR_027112 LINC02112 Silent rs41491 5 9695667 [T/C] NR_027112 LINC02112 Silent rs7713633 5 9695843 [T/G] NR_027112 LINC02112 Silent rs960567 5 9698490 [A/C] NR_027112 LINC02112 Silent rs16883397 5 9698629 [A/G] NR_027112 LINC02112 Silent rs41487 5 9699519 [T/C] NR_027112 LINC02112 Silent rs12519432 5 9699758 [T/C] NR_027112 LINC02112 Silent rs41483 5 9701257 [T/C] NR_027112 LINC02112 Silent rs168788 5 9708576 [T/C] NR_027112 LINC02112 Silent rs194065 5 9709010 [A/G] NR_027112 LINC02112 Silent rs10036822 5 9714227 [A/G] NR_027112 LINC02112 EXON Silent rs118583 5 9715924 [A/C] NR_027112 LINC02112 Silent rs1015855 5 9716549 [T/C] NR_027112 LINC02112 Silent rs4702641 5 9716840 [T/C] NR_027112 LINC02112 Silent rs194060 5 9717016 [A/C] NR_027112 LINC02112 Silent rs1501958 5 9721328 [A/G] NR_027112 LINC02112 Silent rs10067627 5 9727008 [A/G] NR_027112 LINC02112 Silent rs4701849 5 9731900 [A/G] NR_027112 LINC02112 Silent rs10054093 5 9732441 [T/C] NR_027112 LINC02112 Silent rs16883466 5 9737102 [T/C] NR_027112 LINC02112 Silent rs17274475 5 9738382 [A/G] NR_027112 LINC02112 Silent rs3094360 5 9739621 [A/G] NR_027112 LINC02112 Silent rs17334088 5 9741016 [A/G] NR_027112 LINC02112 Silent rs16883500 5 9741430 [T/C] NR_027112 LINC02112 Silent rs7725217 5 9756329 [A/C] NR_027112 LINC02112 Silent rs3110986 5 9758916 [T/C] NR_027112 LINC02112 Silent rs16883522 5 9762567 [T/C] NR_027112 LINC02112 Silent rs3094352 5 9763915 [T/C] NR_027112 LINC02112 Silent rs3110984 5 9764854 [A/G] NR_027112 LINC02112 Silent rs11134367 5 9766668 [A/G] NR_027112 LINC02112 Silent rs3094348 5 9770335 [T/C] NR_027112 LINC02112 Silent rs2905184 5 9781148 [T/C] NR_027112 LINC02112 Silent rs11747629 5 9782136 [T/C] NR_027112 LINC02112 Silent rs1476456 5 9782994 [T/G] NR_027112 LINC02112 Silent rs1008624 5 9790350 [T/G] NR_027112 LINC02112 Silent rs1008253 5 9793237 [A/C] NR_027112 LINC02112 Silent rs3110981 5 9793538 [A/G] NR_027112 LINC02112 Silent rs1006227 5 9797374 [A/G] NR_027112 LINC02112 Silent rs16883565 5 9814581 [A/G] NR_027112 LINC02112 Silent rs2905211 5 9815577 [T/C] NR_027112 LINC02112 Silent rs2027996 5 9816942 [T/C] NR_027112 LINC02112 Silent rs882142 5 9819038 [T/C] NR_027112 LINC02112 Silent rs16883572 5 9821723 [T/C] NR_027112 LINC02112 Silent rs2106358 5 9827532 [T/C] NR_027112 LINC02112 Silent rs2387174 5 9829373 [A/C] NR_027112 LINC02112 Silent rs10491232 5 9830381 [T/C] NR_027112 LINC02112 Silent rs1015588 5 9831983 [T/C] NR_027112 LINC02112 Silent rs1015587 5 9832022 [A/G] NR_027112 LINC02112 Silent rs10070717 5 9834220 [A/G] NR_027112 LINC02112 Silent rs16883639 5 9836777 [T/C] NR_027112 LINC02112 Silent rs13181165 5 9841830 [T/C] NR_027112 LINC02112 Silent rs10069487 5 9841870 [A/G] NR_027112 LINC02112 Silent rs4701850 5 9847262 [A/G] NR_027112 LINC02112 Silent rs12652744 5 9850994 [T/G] NR_027112 LINC02112 Silent rs2214020 5 9852860 [T/C] NR_027112 LINC02112 Silent rs2963906 5 9860402 [A/C] NR_027112 LINC02112 Silent rs17788970 5 9860479 [T/G] NR_027112 LINC02112 Silent rs2963905 5 9860737 [A/C] NR_027112 LINC02112 Silent rs2963904 5 9861402 [A/G] NR_027112 LINC02112 Silent rs11739224 5 9868176 [A/C] NR_027112 LINC02112 Silent rs6898293 5 9869692 [A/G] NR_027112 LINC02112 Silent rs2963899 5 9870587 [A/G] NR_027112 LINC02112 Silent rs9313281 5 9871507 [A/G] NR_027112 LINC02112 Silent rs10491227 5 9871766 [A/G] NR_027112 LINC02112 Silent rs2963894 5 9877169 [A/G] NR_027112 LINC02112 Silent rs17196845 5 9885006 [T/C] NR_027112 LINC02112 Silent rs16883772 5 9888495 [A/C] NR_027112 LINC02112 Silent rs2905191 5 9891201 [A/C] NR_027112 LINC02112 Silent rs17275422 5 9894959 [T/C] NR_027112 LINC02112 Silent rs6555620 5 9896163 [T/C] NR_027112 LINC02112 Silent rs12521751 5 9896255 [A/G] NR_027112 LINC02112 Silent rs10513034 5 9896556 [T/C] NR_027112 LINC02112 Silent rs4701853 5 9896602 [A/G] NR_027112 LINC02112 Silent rs7707030 5 9897923 [T/C] NR_027112 LINC02112 Silent rs10462871 5 9898962 [T/C] NR_027112 LINC02112 Silent rs17335228 5 9899989 [A/G] NR_027112 LINC02112 Silent rs7732991 5 9902403 [T/C] NR_027112 LINC02112 Silent rs10513035 5 9905783 [A/G] rs16883810 5 9907333 [A/G] rs10866596 5 9910876 [A/G] rs6555624 5 9912072 [T/C] rs3925077 5 9915399 [A/G] rs6871808 5 9917666 [A/G] rs10071987 5 9918085 [T/C] rs4272105 5 9919695 [T/C] rs10513039 5 9921028 [A/G] rs17354739 5 9921374 [T/C] rs10036550 5 9923477 [T/C] rs11739710 5 9923541 [T/C] rs10044248 5 9923731 [T/C] rs10746553 5 9924172 [A/G] rs11949879 5 9924597 [A/G] rs1035961 5 9928862 [A/C] rs16883851 5 9932210 [T/C] rs13179743 5 9933220 [A/G] rs12657074 5 9933742 [A/G] rs2914722 5 9939452 [A/C] rs2914723 5 9941041 [T/C] rs1366620 5 9941459 [T/C] rs1428945 5 9941748 [T/C] rs1428946 5 9941841 [A/G] rs1428947 5 9945590 [T/C] rs2914726 5 9946689 [T/G] rs12152749 5 9947222 [T/G] rs1428949 5 9947612 [T/C] rs16883882 5 9947938 [T/C] rs2914727 5 9948096 [T/C] rs1366624 5 9948603 [T/C] rs1366625 5 9948723 [A/G] rs16883890 5 9950908 [A/G] rs7708238 5 9951112 [A/G] rs16883905 5 9956338 [T/C] rs10065959 5 9956601 [A/G] rs6874073 5 9959769 [T/C] rs1428954 5 9963889 [A/G] rs6867995 5 9965794 [T/C] rs38091 5 9967137 [T/C] rs11745764 5 9971532 [A/G] rs38083 5 9977436 [A/G] rs38081 5 9977993 [T/C] rs43224 5 9978292 [A/G] rs38080 5 9978456 [T/C] rs38076 5 9979072 [T/C] rs553169 5 9979084 [T/C] rs38075 5 9979240 [A/G] rs6866016 5 9980315 [A/G] rs10052972 5 9980435 [T/G] rs17196873 5 9981548 [T/C] rs38068 5 9983519 [A/G] rs38066 5 9984400 [A/G] rs38065 5 9984418 [A/C] rs38064 5 9984591 [A/G] rs10866598 5 9984618 [T/C] rs38061 5 9985893 [T/C] rs6875901 5 9987380 [A/G] rs10072374 5 9987909 [T/C] rs10057739 5 9990381 [T/C] rs434147 5 9990529 [A/G] rs395284 5 9990693 [T/C] rs433676 5 9990718 [A/G] rs16883981 5 9997370 [T/C] rs6890044 5 9998256 [T/C] rs17196901 5 9998288 [A/C] rs416393 5 9998328 [T/C] rs6891283 5 9999146 [A/G] rs1395093 5 10018290 [A/G] rs10060537 5 10031142 [A/G] rs314731 5 10031449 [A/G] rs314734 5 10032216 [T/C] rs7735551 5 10032708 [A/G] rs10474658 5 10034362 [T/C] rs1476481 5 10036432 [A/G] rs12658915 5 10040087 [T/C] rs314743 5 10042003 [T/C] rs7729241 5 10044149 [A/G] rs1506030 5 10055916 [A/G] rs10054096 5 10058202 [A/G] rs6554567 5 10058975 [A/G] rs7718749 5 10059451 [A/C] rs16884060 5 10060297 [A/C] rs7703397 5 10063991 [A/C] rs13160983 5 10064591 [A/G] rs1506033 5 10064748 [A/G] rs7719627 5 10067090 [T/C] rs7733499 5 10067429 [T/C] rs10066275 5 10069158 [A/G] rs1876154 5 10072247 [A/G] rs11742768 5 10073956 [A/G] rs4702667 5 10075772 [T/C] rs975326 5 10080699 [T/G] rs10052095 5 10081435 [T/G] rs868928 5 10085178 [T/C] rs924968 5 10085900 [A/G] rs1910995 5 10087511 [T/C] rs35775016 5 10088310 [A/G] rs11747397 5 10098064 [T/C] rs906067 5 10099927 [T/C] rs1532873 5 10105638 [T/C] rs1876150 5 10105947 [T/C] rs11741586 5 10107999 [A/G] rs6886410 5 10108500 [A/G] rs906069 5 10109105 [A/G] rs884355 5 10109791 [A/C] rs11744434 5 10111180 [A/G] rs10060253 5 10111996 [T/C] rs13157877 5 10112089 [A/C] rs4702671 5 10113245 [A/G] rs1876152 5 10113778 [A/G] rs10058915 5 10115230 [A/G] rs10060606 5 10115751 [T/C] rs4484395 5 10116479 [A/G] rs17358279 5 10117405 [A/C] rs10073082 5 10117618 [A/C] rs12188802 5 10117989 [T/G] rs2662424 5 10118153 [T/C] rs2658094 5 10119097 [T/C] rs12654500 5 10125673 [A/G] rs2658110 5 10127557 [T/C] rs1395095 5 10132963 [T/G] rs10066358 5 10134236 [A/G] rs2386594 5 10135248 [T/C] rs2658084 5 10136135 [T/C] rs10050438 5 10139143 [A/G] rs2658080 5 10140391 [A/G] rs6870221 5 10140822 [A/C] rs4409061 5 10142175 [T/C] rs10223312 5 10145304 [T/C] rs7705202 5 10146995 [A/G] rs955376 5 10148758 [T/C] rs6897624 5 10150933 [A/G] rs6868282 5 10152686 [A/G] rs1911942 5 10158297 [T/C] rs2202815 5 10159036 [T/C] rs1508855 5 10161876 [A/G] rs1508854 5 10165356 [T/C] rs13165671 5 10166244 [A/G] rs6861822 5 10172430 [T/C] rs16884244 5 10172635 [T/G] rs13185499 5 10175162 [A/G] rs11133603 5 10191971 [T/C] rs16884265 5 10196616 [A/G] rs2892069 5 10198605 [T/G] rs1508850 5 10202891 [T/C] rs7718725 5 10214571 [T/C] rs10065995 5 10215009 [T/C] rs17294086 5 10217604 [T/C] rs4701865 5 10221905 [T/C] rs4702678 5 10222014 [T/C] rs4701866 5 10223371 [T/C] rs6871733 5 10223386 [A/G] rs12653646 5 10224631 [T/C] rs1045369 5 10226839 [A/G] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B EXON Silent,Silent,Silent,Silent,Silent,Silent rs2136197 5 10227548 [A/C] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B EXON Silent,Silent,Silent,Silent,Silent,Silent rs13360474 5 10233388 [T/C] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B Silent,Silent,Silent,Silent,Silent,Silent rs11133604 5 10233988 [A/G] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B Silent,Silent,Silent,Silent,Silent,Silent rs2292264 5 10235490 [A/G] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B Silent,Silent,Silent,Silent,Silent,Silent rs17360625 5 10236693 [A/G] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B EXON Missense_V114A,Silent,Missense_V114A,Silent,Missense_V114A,Silent rs16884350 5 10236720 [A/G] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B EXON Missense_A105V,Silent,Missense_A105V,Silent,Missense_A105V,Silent rs2292263 5 10236927 [T/C] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B Silent,Silent,Silent,Silent,Silent,Silent rs2438652 5 10239261 [A/G] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B EXON Missense_T75M,Silent,Missense_T75M,Silent,Missense_T75M,Silent rs2445871 5 10239993 [A/G] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B Silent,Silent,Silent,Silent,Silent,Silent rs2607324 5 10240549 [A/G] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B Silent,Silent,Silent,Silent,Silent,Silent rs2607326 5 10240791 [T/C] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B Silent,Silent,Silent,Silent,Silent,Silent rs10037085 5 10241489 [A/G] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B Silent,Silent,Silent,Silent,Silent,Silent rs2607330 5 10241867 [A/G] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B Silent,Silent,Silent,Silent,Silent,Silent rs2578628 5 10242162 [T/C] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B Silent,Silent,Silent,Silent,Silent,Silent rs2578624 5 10245114 [T/C] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B Silent,Silent,Silent,Silent,Silent,Silent rs3844305 5 10248572 [T/C] NM_001258388,NR_047669,NM_199133,NR_047670,NM_001258389,NR_047668 FAM173B,FAM173B,FAM173B,FAM173B,FAM173B,FAM173B Silent,Silent,Silent,Silent,Silent,Silent rs2548546 5 10250430 [A/G] NM_001306154,NM_001306153,NM_012073 CCT5,CCT5,CCT5 EXON Silent,Silent,Silent rs2578618 5 10250443 [T/C] NM_001306154,NM_001306153,NM_012073 CCT5,CCT5,CCT5 EXON Silent,Silent,Silent rs2259642 5 10254117 [T/C] NM_001306154,NM_001306153,NM_012073,NM_001306156,NM_001306155 CCT5,CCT5,CCT5,CCT5,CCT5 Silent,Silent,Silent,Silent,Silent rs3846599 5 10255821 [T/C] NM_001306154,NM_001306153,NM_012073,NM_001306156,NM_001306155 CCT5,CCT5,CCT5,CCT5,CCT5 Silent,Silent,Silent,Silent,Silent rs10067211 5 10257460 [A/G] NM_001306154,NM_001306153,NM_012073,NM_001306156,NM_001306155 CCT5,CCT5,CCT5,CCT5,CCT5 Silent,Silent,Silent,Silent,Silent rs10043031 5 10260247 [A/G] NM_001306154,NM_001306153,NM_012073,NM_001306156,NM_001306155 CCT5,CCT5,CCT5,CCT5,CCT5 Silent,Silent,Silent,Silent,Silent rs11951413 5 10260347 [T/C] NM_001306154,NM_001306153,NM_012073,NM_001306156,NM_001306155 CCT5,CCT5,CCT5,CCT5,CCT5 Silent,Silent,Silent,Silent,Silent rs2292267 5 10263582 [A/G] NM_001306154,NM_001306153,NM_012073,NM_001306156,NM_001306155 CCT5,CCT5,CCT5,CCT5,CCT5 Silent,Silent,Silent,Silent,Silent rs2445872 5 10263692 [T/G] NM_001306154,NM_001306153,NM_012073,NM_001306156,NM_001306155 CCT5,CCT5,CCT5,CCT5,CCT5 Silent,Silent,Silent,Silent,Silent rs2578641 5 10265277 [T/C] NM_001306154,NM_001306153,NM_012073,NM_001306156,NM_001306155 CCT5,CCT5,CCT5,CCT5,CCT5 EXON Silent,Silent,Silent,Silent,Silent rs3852166 5 10281549 [T/C] NM_138809 CMBL Silent rs6871279 5 10283530 [T/C] NM_138809 CMBL Silent rs10038054 5 10290347 [T/C] NM_138809 CMBL Silent rs6867681 5 10291429 [T/C] NM_138809 CMBL Silent rs10060937 5 10291867 [T/C] NM_138809 CMBL Silent rs3857348 5 10297847 [A/G] NM_138809 CMBL Silent rs13359758 5 10301295 [T/C] NM_138809 CMBL Silent rs7702977 5 10306644 [A/G] NM_138809 CMBL Silent rs11738492 5 10307022 [T/C] NM_138809 CMBL Silent rs10072686 5 10308240 [A/G] rs11951923 5 10309122 [A/G] rs13154507 5 10312068 [T/C] rs1287733 5 10315843 [T/C] rs606490 5 10318455 [A/G] rs6892396 5 10333138 [A/G] rs6860972 5 10339738 [T/G] rs4702690 5 10343089 [A/G] rs7737158 5 10348221 [T/C] rs7705244 5 10352786 [A/G] rs6870291 5 10353683 [A/G] rs6887666 5 10356885 [A/G] NM_001270660,NM_001270661,NM_005885 MARCH6,MARCH6,MARCH6 Silent,Silent,Silent rs13155132 5 10361110 [T/G] NM_001270660,NM_001270661,NM_005885 MARCH6,MARCH6,MARCH6 Silent,Silent,Silent rs12054882 5 10391678 [A/G] NM_001270660,NM_001270661,NM_005885 MARCH6,MARCH6,MARCH6 EXON Missense_E153K,Missense_E96K,Missense_E201K rs2567564 5 10394583 [A/G] NM_001270660,NM_001270661,NM_005885 MARCH6,MARCH6,MARCH6 Silent,Silent,Silent rs16884635 5 10394801 [A/G] NM_001270660,NM_001270661,NM_005885 MARCH6,MARCH6,MARCH6 Silent,Silent,Silent rs2567588 5 10413501 [T/C] NM_001270660,NM_001270661,NM_005885 MARCH6,MARCH6,MARCH6 Silent,Silent,Silent rs2967956 5 10417589 [T/G] NM_001270660,NM_001270661,NM_005885 MARCH6,MARCH6,MARCH6 Silent,Silent,Silent rs2589668 5 10434643 [A/G] NM_001270660,NM_001270661,NM_005885 MARCH6,MARCH6,MARCH6 EXON Silent,Silent,Silent rs1987 5 10440366 [T/C] NM_001270660,NM_001270661,NM_005885 MARCH6,MARCH6,MARCH6 EXON Silent,Silent,Silent rs12520017 5 10441587 [T/G] NR_102746 ROPN1L-AS1 Silent rs12521546 5 10444131 [A/G] NM_001201466,NM_031916 ROPN1L,ROPN1L Silent,Silent rs2011318 5 10446124 [A/G] NM_001201466,NM_031916 ROPN1L,ROPN1L Silent,Silent rs6859579 5 10447247 [A/G] NM_001201466,NM_031916 ROPN1L,ROPN1L Silent,Silent rs1976360 5 10448247 [A/G] NM_001201466,NM_031916 ROPN1L,ROPN1L Silent,Silent rs1875017 5 10451154 [A/G] NM_001201466,NM_031916 ROPN1L,ROPN1L Silent,Silent rs2088626 5 10459555 [A/G] NM_001201466,NM_031916 ROPN1L,ROPN1L Silent,Silent rs1814856 5 10459942 [T/C] NM_001201466,NM_031916 ROPN1L,ROPN1L Silent,Silent rs2673855 5 10460216 [T/C] NM_001201466,NM_031916 ROPN1L,ROPN1L Silent,Silent rs2567575 5 10460700 [T/C] NM_001201466,NM_031916 ROPN1L,ROPN1L Silent,Silent rs7733299 5 10463335 [A/G] NM_001201466,NM_031916 ROPN1L,ROPN1L Silent,Silent rs12520289 5 10467257 [A/C] rs3932191 5 10470025 [A/G] rs7711645 5 10472134 [A/G] rs2962318 5 10476520 [T/G] rs2936582 5 10476759 [T/G] rs2589653 5 10478341 [T/C] rs2589654 5 10478798 [T/G] rs2962330 5 10481725 [A/G] rs17759853 5 10489579 [A/G] rs2589661 5 10492095 [T/C] rs13180425 5 10492322 [T/C] rs6892802 5 10496509 [T/C] NR_104606 LINC02212 Silent rs7732984 5 10497207 [T/C] NR_104606 LINC02212 Silent rs2589658 5 10501076 [A/C] NR_104606 LINC02212 Silent rs2919756 5 10503977 [A/G] rs17816571 5 10505585 [A/G] NR_134290,NR_134289 LINC02213,LINC02213 EXON Silent,Silent rs1971391 5 10512330 [A/G] NR_134289 LINC02213 Silent rs6883094 5 10512454 [T/G] NR_134289 LINC02213 Silent rs4235597 5 10512572 [A/G] NR_134289 LINC02213 Silent rs4702698 5 10517908 [A/G] NR_134289 LINC02213 Silent rs2962327 5 10522013 [T/C] NR_134289 LINC02213 EXON Silent rs2962325 5 10523116 [A/G] rs2895545 5 10524503 [A/G] rs2673892 5 10525349 [T/C] rs2962332 5 10530684 [A/G] rs2936577 5 10531620 [A/G] rs814586 5 10531998 [A/G] rs6887463 5 10532639 [T/C] rs2589656 5 10537351 [A/G] rs2962322 5 10541520 [A/G] rs814589 5 10541625 [A/C] rs2936590 5 10547018 [T/C] rs2673891 5 10547032 [A/G] rs1392006 5 10552459 [T/C] rs1399830 5 10552667 [T/C] rs2062462 5 10553563 [A/G] rs2399910 5 10568417 [A/G] NM_001164440 ANKRD33B Silent rs12522627 5 10568591 [A/G] NM_001164440 ANKRD33B Silent rs2648802 5 10569829 [T/C] NM_001164440 ANKRD33B Silent rs959219 5 10574343 [A/G] NM_001164440 ANKRD33B Silent rs2589663 5 10581830 [T/C] NM_001164440 ANKRD33B Silent rs2648804 5 10583537 [A/G] NM_001164440 ANKRD33B Silent rs7712927 5 10585111 [A/C] NM_001164440 ANKRD33B Silent rs9790911 5 10585287 [A/G] NM_001164440 ANKRD33B Silent rs11737977 5 10588033 [T/C] NM_001164440 ANKRD33B Silent rs6869928 5 10589502 [T/C] NM_001164440 ANKRD33B Silent rs4702704 5 10591672 [A/G] NM_001164440 ANKRD33B Silent rs13185308 5 10594061 [T/C] NM_001164440 ANKRD33B Silent rs12187420 5 10604975 [A/G] NM_001164440 ANKRD33B Silent rs1384731 5 10607797 [A/G] NM_001164440 ANKRD33B Silent rs10474877 5 10611579 [T/C] NM_001164440 ANKRD33B Silent rs10035299 5 10612627 [A/G] NM_001164440 ANKRD33B Silent rs6883387 5 10616846 [T/C] NM_001164440 ANKRD33B Silent rs6871080 5 10617670 [A/G] NM_001164440 ANKRD33B Silent rs4701875 5 10617984 [A/G] NM_001164440 ANKRD33B Silent rs11948562 5 10619490 [T/C] NM_001164440 ANKRD33B Silent rs11748401 5 10620085 [A/G] NM_001164440 ANKRD33B Silent rs879143 5 10620274 [T/C] NM_001164440 ANKRD33B Silent rs11749155 5 10620642 [A/G] NM_001164440 ANKRD33B Silent rs1473447 5 10621173 [A/G] NM_001164440 ANKRD33B Silent rs1531839 5 10624887 [T/C] NM_001164440 ANKRD33B Silent rs1483300 5 10627449 [A/G] NM_001164440 ANKRD33B Silent rs6896826 5 10631178 [T/C] NM_001164440 ANKRD33B Silent rs7703985 5 10635947 [T/C] NM_001164440 ANKRD33B Silent rs900531 5 10636151 [A/G] NM_001164440 ANKRD33B Silent rs11745612 5 10638180 [T/C] NM_001164440 ANKRD33B EXON Synonymous_P179P rs6894331 5 10652117 [T/C] NM_001164440 ANKRD33B EXON Silent rs3822410 5 10654769 [C/G] NM_001164440 ANKRD33B EXON Silent rs34091808 5 10667969 [T/C] rs4702718 5 10671040 [A/G] rs1531842 5 10675766 [T/G] rs13168857 5 10676692 [T/G] rs4702722 5 10677339 [A/G] rs5745308 5 10678281 [T/C] rs7973 5 10679746 [T/C] NM_001291963,NM_004394 DAP,DAP EXON Silent,Silent rs1049344 5 10680487 [A/G] NM_001291963,NM_004394 DAP,DAP EXON Silent,Silent rs9857 5 10680547 [T/C] NM_001291963,NM_004394 DAP,DAP EXON Silent,Silent rs10271 5 10680749 [A/G] NM_001291963,NM_004394 DAP,DAP EXON Silent,Silent rs1866386 5 10682728 [A/G] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs3797111 5 10685185 [T/G] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs3776414 5 10689562 [T/G] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs3776415 5 10689636 [A/C] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs6891527 5 10693687 [A/G] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs2930047 5 10695526 [T/C] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs3756407 5 10701514 [A/G] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs3756408 5 10701615 [A/G] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs2918394 5 10702034 [A/G] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs3822414 5 10702688 [T/C] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs2930051 5 10704622 [T/C] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs3797126 5 10707870 [T/C] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs267988 5 10710716 [A/G] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs388376 5 10731134 [T/C] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs2918386 5 10734647 [A/G] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs1866385 5 10736569 [T/C] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs267957 5 10738444 [T/C] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs17831254 5 10738938 [T/C] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs267949 5 10743929 [T/C] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs2930058 5 10744450 [A/G] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs16898820 5 10751565 [T/C] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs267939 5 10752315 [T/C] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs2930059 5 10753399 [A/G] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs182073 5 10760373 [A/G] NM_001291963,NM_004394 DAP,DAP Silent,Silent rs13153621 5 10771228 [T/C] rs2964788 5 10777617 [T/G] rs11740309 5 10785424 [T/C] rs2964798 5 10788833 [T/C] rs13155209 5 10788919 [T/G] rs2964796 5 10789570 [T/C] rs2964794 5 10793865 [T/C] rs2964793 5 10795348 [T/C] rs1866387 5 10798221 [A/C] rs1470023 5 10800150 [T/C] rs7700363 5 10800714 [A/G] rs12186813 5 10802749 [A/C] rs16885373 5 10807667 [A/C] rs7725091 5 10810604 [T/C] rs1438715 5 10811058 [T/C] rs2083232 5 10812811 [A/G] rs9312743 5 10818236 [A/G] rs1438712 5 10818452 [A/G] rs6554603 5 10819285 [T/C] rs4304054 5 10827151 [A/G] rs16901049 5 10834014 [T/C] rs13157690 5 10836485 [A/G] rs13159908 5 10838358 [T/C] rs10474893 5 10842988 [A/G] rs4398608 5 10847970 [T/G] rs6554607 5 10850197 [T/G] rs6895554 5 10852652 [T/C] rs4285191 5 10853693 [T/G] rs12655316 5 10855731 [T/C] rs13185834 5 10857683 [T/G] rs4701885 5 10863028 [T/C] rs13157531 5 10866460 [T/C] rs6872063 5 10876522 [T/C] rs4361487 5 10877143 [T/C] rs4701891 5 10878114 [A/G] rs12188457 5 10878782 [A/C] rs6860099 5 10883440 [A/G] rs10072111 5 10886445 [A/G] rs10065278 5 10886564 [T/C] rs12522996 5 10887902 [T/C] rs17197013 5 10891642 [A/G] rs6893506 5 10894790 [A/G] rs16901104 5 10898059 [A/G] rs4702757 5 10900033 [T/C] rs17789137 5 10900487 [A/C] rs1995364 5 10903781 [A/G] rs6554614 5 10905445 [A/G] rs11133633 5 10907870 [A/C] rs10491237 5 10912382 [T/C] rs10058973 5 10913841 [T/C] rs17197055 5 10914119 [A/C] rs16898829 5 10914151 [T/C] rs17197062 5 10914403 [T/C] rs9686531 5 10916640 [T/C] rs12520057 5 10918265 [A/G] rs2399984 5 10924404 [T/C] rs1354134 5 10929785 [A/G] rs4701901 5 10934026 [T/C] rs13357458 5 10935007 [T/C] rs852556 5 10935557 [T/C] rs16901136 5 10935873 [A/C] rs852560 5 10937683 [A/G] rs11133634 5 10938199 [A/G] rs10474905 5 10938228 [T/C] rs16901148 5 10938356 [A/G] rs852562 5 10940352 [A/C] rs852563 5 10941988 [T/C] rs852564 5 10942243 [T/C] rs16901149 5 10943255 [T/C] rs16901155 5 10946582 [T/C] rs970133 5 10951133 [T/C] rs860434 5 10954186 [T/C] rs1501776 5 10955488 [T/C] rs1501777 5 10955552 [A/G] rs852586 5 10955988 [T/C] rs1501778 5 10956146 [T/C] rs2937509 5 10958635 [T/G] rs2937502 5 10963403 [A/G] rs11133635 5 10964557 [T/G] rs2907122 5 10965031 [T/C] rs12188188 5 10968872 [T/G] rs3734130 5 10973237 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 EXON Silent,Silent,Silent,Silent,Silent,Silent rs1566622 5 10973727 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 EXON Synonymous_F1081F,Silent,Synonymous_F1172F,Synonymous_F739F,Synonymous_F835F,Synonymous_F860F rs1566624 5 10973927 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs7728798 5 10976530 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2062685 5 10984610 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2062688 5 10984714 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10434650 5 10986947 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs12520815 5 10987093 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10434651 5 10987114 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs706306 5 10998665 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs4702781 5 11002126 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6878664 5 11005150 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs852614 5 11006477 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs852619 5 11011206 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10044577 5 11011856 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs852620 5 11011945 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1501772 5 11014035 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs852623 5 11015971 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs852625 5 11016111 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2302179 5 11017952 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1697901 5 11019405 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1638362 5 11020804 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs16901205 5 11020918 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs7702184 5 11024270 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs17179868 5 11028344 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1116698 5 11030164 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1638364 5 11032225 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2400005 5 11035367 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs852633 5 11037450 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs852635 5 11042858 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs852636 5 11045100 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs11745793 5 11046606 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs852640 5 11050264 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1024618 5 11054511 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1860242 5 11069269 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10513065 5 11075599 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2973522 5 11075691 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10513066 5 11076061 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs11744876 5 11084712 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2907105 5 11086565 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs758341 5 11087322 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs11133637 5 11087563 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs9312754 5 11088028 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs16901246 5 11089822 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2973511 5 11095315 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2905997 5 11096972 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2905992 5 11104937 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2905986 5 11111713 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6884431 5 11111771 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs11954029 5 11114201 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs11133644 5 11114804 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs7341140 5 11115483 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2285975 5 11117583 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 EXON Synonymous_G661G,Silent,Synonymous_G752G,Synonymous_G319G,Synonymous_G415G,Synonymous_G415G rs6554619 5 11118144 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs7700861 5 11124555 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2023923 5 11126791 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6865035 5 11131114 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10513073 5 11134772 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2214599 5 11136893 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs12516033 5 11145866 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10073056 5 11146253 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs12516262 5 11147575 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs886527 5 11147814 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs12514212 5 11148537 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10055024 5 11149808 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs13358276 5 11154447 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs13158585 5 11155378 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1990004 5 11156272 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2277054 5 11160043 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2023916 5 11161237 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1978156 5 11161625 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2057794 5 11162725 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs7703504 5 11163984 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs721768 5 11164361 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs12716080 5 11166948 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs7713461 5 11167277 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs16901339 5 11169601 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6885224 5 11169945 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs13188937 5 11172241 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6883143 5 11172736 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs16901347 5 11172773 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1018965 5 11175485 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1012092 5 11176387 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs13179953 5 11179193 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10062829 5 11179494 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs32280 5 11186652 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs32274 5 11190998 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs153607 5 11194840 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs16901390 5 11195687 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs32270 5 11197025 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs4702794 5 11200596 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs27720 5 11201861 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs26461 5 11202649 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1302802 5 11203426 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6879492 5 11205980 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2036319 5 11214203 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs27520 5 11218488 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs398041 5 11218850 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs154717 5 11234229 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs28038 5 11236914 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 EXON Synonymous_P459P,Silent,Synonymous_P550P,Synonymous_P117P,Synonymous_P213P,Synonymous_P213P rs10474912 5 11239180 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1500156 5 11241313 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs32064 5 11249206 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs194487 5 11252267 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs181889 5 11256115 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs26464 5 11269715 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs441973 5 11277256 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs32100 5 11280739 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs258634 5 11285548 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs4702797 5 11286173 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs386658 5 11286825 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs447587 5 11287502 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs881675 5 11290530 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs13160436 5 11291539 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2530215 5 11298223 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs40403 5 11299801 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6869903 5 11300854 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs27446 5 11301611 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs26000 5 11302022 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs28210 5 11302152 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6860372 5 11303097 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs27669 5 11303492 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs26001 5 11303908 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs26478 5 11304423 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs26002 5 11304750 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs17794637 5 11305217 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs28863 5 11305991 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1015493 5 11306627 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs16901472 5 11306983 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs406309 5 11310423 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs258638 5 11310554 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs32119 5 11313143 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs32118 5 11313232 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs16901481 5 11317439 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1012176 5 11320538 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2012187 5 11322037 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs258837 5 11322374 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs4702798 5 11324554 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs258839 5 11329757 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs32139 5 11333739 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs32138 5 11335373 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs32136 5 11336674 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6869392 5 11337346 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs32135 5 11339984 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1423497 5 11341218 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs32128 5 11343384 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs4702799 5 11346156 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6881516 5 11347020 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs40289 5 11349674 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1978462 5 11361864 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2158099 5 11362268 [C/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1423493 5 11363645 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2074260 5 11365166 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs11750088 5 11366401 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6875838 5 11368864 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6891903 5 11371305 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1859082 5 11372743 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs7725550 5 11374223 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs7702488 5 11378282 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs9312768 5 11378817 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2113012 5 11380155 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs12518049 5 11381138 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs40485 5 11390193 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs154753 5 11392036 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs17802557 5 11397188 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 EXON Synonymous_P98P,Silent,Synonymous_P189P,Silent,Silent,Silent rs31837 5 11397573 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs7720778 5 11399734 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs1469099 5 11410718 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs16901615 5 11418914 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10065615 5 11422171 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10513091 5 11423525 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs31887 5 11423592 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs31888 5 11423628 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs31895 5 11428476 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs31896 5 11428508 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs31897 5 11428523 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs31899 5 11429782 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs7710716 5 11432888 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10044905 5 11438117 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs31830 5 11440686 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs249237 5 11441822 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs31961 5 11448668 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs11133654 5 11452037 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs31954 5 11455872 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs31947 5 11461390 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10462668 5 11461920 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2244828 5 11469640 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs249268 5 11479472 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs249264 5 11481099 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10513094 5 11482045 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs26147 5 11482412 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs17216753 5 11484112 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs26150 5 11487585 [A/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs17805650 5 11490932 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs11959871 5 11496708 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs249236 5 11502495 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs26163 5 11507294 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs16901689 5 11507368 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs17218080 5 11507879 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs10038337 5 11512457 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs4702809 5 11518138 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs32625 5 11518163 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs12523633 5 11518704 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs32434 5 11523516 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs31780 5 11528719 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs16901719 5 11529042 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs13160599 5 11529117 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs7731185 5 11530088 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs31784 5 11530762 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6871714 5 11538361 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6893111 5 11538379 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs6554630 5 11538504 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs13170650 5 11539795 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2530904 5 11543318 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2561621 5 11544026 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs11750073 5 11548050 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2561596 5 11548147 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs11740843 5 11552229 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs13173482 5 11552620 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2530908 5 11556824 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2530910 5 11563028 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs7719578 5 11564995 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2727607 5 11566665 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2727588 5 11571940 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2190988 5 11572318 [T/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2727590 5 11573514 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2727591 5 11577141 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2727612 5 11582048 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2190989 5 11584342 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs7731344 5 11584449 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2530913 5 11585455 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs2429308 5 11586703 [T/C] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs364327 5 11588818 [A/G] NM_001288715,NR_109988,NM_001332,NM_001288717,NM_001288716,NM_001364128 CTNND2,CTNND2,CTNND2,CTNND2,CTNND2,CTNND2 Silent,Silent,Silent,Silent,Silent,Silent rs7713093 5 11593348 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs247648 5 11593436 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs17221495 5 11597332 [A/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs10513101 5 11599392 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs10055710 5 11607481 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs16901810 5 11621007 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs2727583 5 11623406 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs2561601 5 11632166 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs1428514 5 11636016 [T/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs7721305 5 11640694 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs2561598 5 11641039 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs2727594 5 11655830 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs10474928 5 11658814 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs10462670 5 11677173 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs6883905 5 11696211 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs3891746 5 11702017 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs10041174 5 11710193 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs13186564 5 11711684 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs1896703 5 11712057 [T/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs1025294 5 11714657 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs7722253 5 11716407 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs6861373 5 11720017 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs12332227 5 11722359 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs10474932 5 11724821 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs7732155 5 11730324 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs4466167 5 11732468 [A/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs11952405 5 11736524 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs11955159 5 11737875 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs4702813 5 11742668 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs13156582 5 11745176 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs10039367 5 11746124 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs10866485 5 11767981 [T/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs6867416 5 11775395 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs6554641 5 11801562 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs6554644 5 11807432 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs10078846 5 11809016 [A/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs3924181 5 11822833 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs1947610 5 11827280 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs7731468 5 11831211 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs1458475 5 11839171 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs7733427 5 11843303 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs11951681 5 11854197 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs7379525 5 11855867 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs13177858 5 11859518 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs6897411 5 11861884 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs12652699 5 11864077 [A/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs10474938 5 11864585 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs4702836 5 11865658 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs4379193 5 11867393 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs6554653 5 11870138 [T/C] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs4701924 5 11870554 [T/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs1870329 5 11874565 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs1870330 5 11878654 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs12514516 5 11893757 [A/G] NR_109988,NM_001332,NM_001288717 CTNND2,CTNND2,CTNND2 Silent,Silent,Silent rs6554656 5 11906448 [A/C] rs2061392 5 11908641 [T/C] rs2400094 5 11910541 [T/C] rs13173187 5 11913471 [A/G] rs7713607 5 11918903 [T/G] rs2125388 5 11924237 [A/G] rs10064613 5 11926837 [A/C] rs6884647 5 11929913 [T/G] rs12651763 5 11945135 [A/G] rs9284958 5 11945254 [A/G] rs1379902 5 11949787 [T/C] rs1379903 5 11953353 [T/C] rs4440358 5 11965136 [A/G] rs6898814 5 11965483 [T/C] rs4642366 5 11982921 [A/G] rs12517373 5 11990887 [A/G] rs1026474 5 12003910 [T/C] rs4541658 5 12017548 [A/G] rs6886871 5 12021831 [T/C] rs12054798 5 12035993 [A/G] rs11746688 5 12040493 [A/G] rs4318778 5 12049381 [T/C] rs10462685 5 12060670 [T/C] rs7448095 5 12061296 [T/C] rs7446603 5 12084583 [A/G] rs11748276 5 12084728 [A/G] rs4413531 5 12085304 [A/G] rs4601043 5 12102037 [T/G] rs6875403 5 12109995 [T/C] rs12522823 5 12113211 [T/C] rs12513897 5 12114723 [T/C] rs4702850 5 12120335 [T/C] rs10074947 5 12121733 [T/C] rs32323 5 12132401 [A/G] rs250780 5 12153033 [A/G] rs2907283 5 12163018 [A/G] rs10491238 5 12164978 [A/G] rs2968125 5 12167533 [T/C] rs17789360 5 12174121 [T/C] rs10040729 5 12176133 [T/C] rs11745148 5 12181811 [T/C] rs2968088 5 12187959 [T/C] rs2968095 5 12196488 [T/C] rs2215256 5 12202885 [T/C] rs2191102 5 12206786 [T/G] rs1112926 5 12227134 [T/C] rs16902096 5 12228059 [A/G] rs11956598 5 12229015 [T/G] rs2966901 5 12238948 [A/G] rs4440360 5 12243796 [A/C] rs16902110 5 12251916 [A/G] rs16902115 5 12258404 [A/G] rs17824844 5 12261173 [A/G] rs1113173 5 12263385 [A/G] rs10038634 5 12269621 [T/C] rs10054484 5 12271190 [A/G] rs10043127 5 12280849 [T/C] rs2966898 5 12285739 [T/C] rs7711626 5 12288541 [A/G] rs11133706 5 12310717 [T/C] rs2191015 5 12318620 [T/C] rs2215207 5 12321300 [A/G] rs6891532 5 12338203 [A/G] rs10072442 5 12342266 [A/G] rs2400151 5 12358990 [A/C] rs12658793 5 12361830 [A/G] rs2215202 5 12378106 [A/G] rs2052036 5 12389594 [A/G] rs2052035 5 12389751 [T/C] rs6554700 5 12392815 [T/C] rs12519082 5 12394645 [A/G] rs7708669 5 12401130 [T/C] rs7736493 5 12407352 [T/C] rs9312801 5 12437894 [T/C] rs6554711 5 12448703 [T/C] rs32248 5 12468013 [T/G] rs6869431 5 12474672 [T/C] rs16902224 5 12482460 [T/G] rs32240 5 12483499 [A/C] rs245682 5 12484279 [A/G] rs245684 5 12496452 [A/G] rs11133718 5 12500383 [T/C] rs13159457 5 12501213 [A/C] rs2895925 5 12507269 [A/G] rs12653370 5 12507398 [A/G] rs32374 5 12510848 [A/G] rs32367 5 12515215 [T/C] rs32358 5 12532357 [A/C] rs7703319 5 12543792 [T/C] rs16902247 5 12550857 [T/C] rs6871750 5 12566885 [T/G] rs4558988 5 12572670 [T/C] rs4566790 5 12577738 [A/G] NR_033383 LINC01194 Silent rs4247241 5 12587264 [A/C] NR_033383 LINC01194 Silent rs10474965 5 12589411 [T/G] NR_033383 LINC01194 Silent rs12187460 5 12597678 [A/C] NR_033383 LINC01194 Silent rs10038940 5 12597846 [A/C] NR_033383 LINC01194 Silent rs7449177 5 12599348 [T/C] NR_033383 LINC01194 Silent rs11749872 5 12606091 [A/G] NR_033383 LINC01194 Silent rs7710465 5 12629482 [A/G] NR_033383 LINC01194 Silent rs12659350 5 12633456 [A/G] NR_033383 LINC01194 Silent rs7449389 5 12634856 [A/G] NR_033383 LINC01194 Silent rs7449345 5 12634890 [A/G] NR_033383 LINC01194 Silent rs10068669 5 12641719 [A/G] NR_033383 LINC01194 Silent rs7733480 5 12642449 [T/G] NR_033383 LINC01194 Silent rs4701945 5 12652188 [T/C] NR_033383 LINC01194 Silent rs11746503 5 12675698 [T/G] NR_033383 LINC01194 Silent rs7716313 5 12682143 [T/G] NR_033383 LINC01194 Silent rs6869725 5 12697079 [A/G] NR_033383 LINC01194 Silent rs13182649 5 12698832 [A/G] NR_033383 LINC01194 Silent rs7728700 5 12710981 [A/G] NR_033383 LINC01194 Silent rs12658137 5 12719263 [A/C] NR_033383 LINC01194 Silent rs6880752 5 12726490 [A/C] NR_033383 LINC01194 Silent rs12659128 5 12733263 [A/G] NR_033383 LINC01194 Silent rs6862501 5 12749695 [T/C] NR_033383 LINC01194 Silent rs11133726 5 12766945 [A/C] NR_033383 LINC01194 Silent rs13164269 5 12772609 [A/G] NR_033383 LINC01194 Silent rs9312811 5 12778499 [A/G] NR_033383 LINC01194 Silent rs4277918 5 12780942 [T/G] NR_033383 LINC01194 Silent rs4495184 5 12781239 [T/G] NR_033383 LINC01194 Silent rs12186744 5 12784265 [A/C] NR_033383 LINC01194 Silent rs13355523 5 12785362 [A/G] NR_033383 LINC01194 Silent rs12188566 5 12785895 [T/C] NR_033383 LINC01194 Silent rs7720957 5 12786912 [T/C] NR_033383 LINC01194 Silent rs10073652 5 12786980 [T/C] NR_033383 LINC01194 Silent rs7734051 5 12834853 [T/C] rs1898630 5 12948221 [T/C] NR_147005 LINC02220 Silent rs16902341 5 12968815 [T/C] NR_147005 LINC02220 Silent rs2118584 5 12975063 [T/C] NR_147005 LINC02220 Silent rs1017454 5 12975322 [A/G] NR_147005 LINC02220 Silent rs16902347 5 12977507 [T/C] NR_147005 LINC02220 Silent rs16902349 5 12978580 [A/G] NR_147005 LINC02220 Silent rs745671 5 12986808 [T/G] NR_147005 LINC02220 Silent rs16902361 5 12995938 [T/C] NR_147005 LINC02220 Silent rs17239989 5 13013974 [A/C] NR_147005 LINC02220 Silent rs13163690 5 13015270 [T/C] NR_147005 LINC02220 Silent rs17240093 5 13015303 [A/G] NR_147005 LINC02220 Silent rs16902371 5 13017177 [T/C] NR_147005 LINC02220 Silent rs17253174 5 13019834 [A/C] NR_147005 LINC02220 Silent rs16902392 5 13078246 [T/C] rs32534 5 13149677 [A/C] rs40406 5 13201512 [A/G] rs12716096 5 13207967 [A/G] rs1445728 5 13207997 [A/G] rs16902421 5 13209817 [T/C] rs1445730 5 13213877 [A/G] rs32518 5 13213930 [A/G] rs12519301 5 13218289 [A/C] rs10073871 5 13221409 [T/C] rs1373950 5 13221613 [A/G] rs962673 5 13235570 [T/C] rs1596773 5 13236478 [A/G] rs11750718 5 13237009 [A/G] rs11744248 5 13237036 [T/C] rs6554760 5 13238542 [A/G] rs10066447 5 13242974 [T/C] rs4391159 5 13243126 [A/G] rs4522991 5 13246979 [A/G] rs13163486 5 13249445 [A/C] rs12522258 5 13252798 [A/C] rs7710793 5 13256587 [A/G] rs13164328 5 13256986 [A/G] rs4355523 5 13262573 [A/G] rs6554770 5 13270090 [T/C] rs10462705 5 13276651 [T/C] rs13153960 5 13278199 [T/C] rs12691269 5 13283522 [T/C] rs1446046 5 13287359 [T/G] rs2028845 5 13293074 [A/G] rs10055552 5 13297813 [T/G] rs1374089 5 13312470 [A/C] rs1446056 5 13329001 [T/C] rs4702930 5 13332729 [A/C] rs7705675 5 13334380 [T/C] rs1900194 5 13340781 [T/G] rs6891686 5 13344447 [T/C] rs978845 5 13348985 [T/C] rs13162209 5 13349497 [A/G] rs7713347 5 13353727 [T/G] rs11133749 5 13367397 [T/C] rs1446049 5 13372239 [T/G] rs1037112 5 13374095 [A/G] rs4574541 5 13376546 [A/G] rs13167986 5 13380973 [T/C] rs1867742 5 13392571 [T/C] rs2067587 5 13393197 [A/C] rs10037689 5 13393591 [A/C] rs985765 5 13394171 [A/G] rs11956313 5 13395707 [T/C] rs7731918 5 13397992 [T/C] rs7721512 5 13399475 [A/G] rs10513138 5 13401407 [T/C] rs2081944 5 13405946 [T/G] rs16902549 5 13407347 [T/C] rs749224 5 13409868 [A/C] rs7724160 5 13415984 [T/C] rs10085086 5 13424707 [A/C] rs1864096 5 13425919 [T/C] rs11960233 5 13430032 [A/G] rs6895189 5 13430225 [A/C] rs6863880 5 13434851 [T/G] rs1366429 5 13441359 [T/C] rs2042955 5 13444174 [T/C] rs4454051 5 13448037 [T/C] rs956195 5 13453436 [A/G] rs1373992 5 13458367 [A/G] rs983830 5 13459048 [A/C] rs10474980 5 13464078 [A/G] rs230076 5 13465905 [T/C] rs972707 5 13471156 [A/G] rs10035331 5 13476407 [T/G] rs6878272 5 13481512 [T/C] rs3853114 5 13481754 [A/G] rs10057809 5 13482159 [A/C] rs3853117 5 13488819 [T/C] rs151151 5 13488878 [T/C] rs151140 5 13493254 [A/G] rs230681 5 13494184 [T/C] rs230049 5 13498598 [T/G] rs6881358 5 13500023 [A/G] rs230042 5 13501102 [T/C] rs3870147 5 13504134 [A/C] rs7712828 5 13510647 [A/G] rs1992711 5 13510918 [A/G] rs10491319 5 13512995 [T/C] rs230068 5 13520973 [A/G] rs230063 5 13525819 [T/C] rs11744397 5 13531164 [A/C] rs11741361 5 13534494 [T/C] rs10076563 5 13545172 [T/C] rs10866500 5 13559762 [A/C] rs233348 5 13572053 [T/C] rs233364 5 13583651 [T/C] rs1428280 5 13587660 [T/C] rs233362 5 13588726 [T/C] rs4702961 5 13589212 [T/C] rs233339 5 13592971 [T/C] rs7703128 5 13595112 [T/C] rs6889477 5 13598206 [T/C] rs1428274 5 13601207 [T/C] rs6877509 5 13603068 [T/C] rs442392 5 13603883 [A/C] rs424270 5 13604919 [A/G] rs13180663 5 13604996 [T/C] rs10035874 5 13609659 [A/G] rs443542 5 13610706 [A/G] rs408619 5 13611631 [T/C] rs389953 5 13619926 [T/G] rs1373947 5 13624894 [A/C] rs2676245 5 13628062 [A/G] rs10075199 5 13628954 [T/G] rs1816896 5 13635807 [A/C] rs1445678 5 13643405 [T/G] rs11746515 5 13645988 [T/C] rs1867658 5 13655022 [A/G] rs1445682 5 13656808 [T/C] rs10036111 5 13659078 [T/C] rs6892801 5 13668719 [T/C] rs6871272 5 13668821 [A/G] rs10056012 5 13681524 [A/G] rs10062092 5 13689874 [A/G] rs6872375 5 13693277 [A/G] NM_001369 DNAH5 Silent rs3734111 5 13701525 [T/C] NM_001369 DNAH5 EXON Synonymous_T4453T rs3734110 5 13701536 [T/C] NM_001369 DNAH5 EXON Missense_I4450V rs10040637 5 13703493 [A/G] NM_001369 DNAH5 Silent rs13169297 5 13706625 [A/G] NM_001369 DNAH5 Silent rs10077457 5 13714568 [A/G] NM_001369 DNAH5 EXON Synonymous_A4357A rs30175 5 13714740 [A/G] NM_001369 DNAH5 Silent rs30169 5 13719022 [T/G] NM_001369 DNAH5 EXON Synonymous_G4156G rs17262853 5 13719434 [A/C] NM_001369 DNAH5 Silent rs17203442 5 13721378 [A/G] NM_001369 DNAH5 Silent rs2652768 5 13723743 [A/G] NM_001369 DNAH5 Silent rs11133760 5 13727212 [A/C] NM_001369 DNAH5 Silent rs10513151 5 13728151 [T/C] NM_001369 DNAH5 Silent rs3734109 5 13735892 [T/C] NM_001369 DNAH5 Silent VG05S27231 5 13735969 [A/G] NM_001369 DNAH5 EXON Missense_S3843L rs17263496 5 13737444 [A/G] NM_001369 DNAH5 EXON Missense_T3791I rs2896104 5 13739720 [T/G] NM_001369 DNAH5 Silent rs6554809 5 13740976 [T/C] NM_001369 DNAH5 Silent rs6881967 5 13741163 [A/C] NM_001369 DNAH5 Silent rs6554811 5 13742858 [T/G] NM_001369 DNAH5 Silent rs1502045 5 13745719 [A/C] NM_001369 DNAH5 Silent VG05S26940 5 13754312 [G/C] NM_001369 DNAH5 EXON Missense_G3519R rs1393270 5 13755672 [T/G] NM_001369 DNAH5 Silent rs7733137 5 13760548 [T/C] NM_001369 DNAH5 Silent rs1354187 5 13760721 [T/C] NM_001369 DNAH5 Silent rs1354186 5 13761033 [T/C] NM_001369 DNAH5 Silent rs1354185 5 13761068 [T/C] NM_001369 DNAH5 Silent rs6554812 5 13762972 [T/C] NM_001369 DNAH5 EXON Synonymous_E3380E rs10513153 5 13770000 [T/C] NM_001369 DNAH5 Silent rs1910092 5 13781480 [A/G] NM_001369 DNAH5 Silent rs4701984 5 13782801 [T/C] NM_001369 DNAH5 Silent rs10513155 5 13788886 [A/C] NM_001369 DNAH5 EXON Missense_L2862F rs795544 5 13798559 [A/C] NM_001369 DNAH5 Silent rs795543 5 13798819 [T/C] NM_001369 DNAH5 Silent rs795542 5 13800577 [T/C] NM_001369 DNAH5 Silent rs10078391 5 13811775 [T/C] NM_001369 DNAH5 EXON Missense_Q2463R rs17265607 5 13814353 [A/C] NM_001369 DNAH5 Silent rs6876105 5 13815288 [T/C] NM_001369 DNAH5 Silent rs16902777 5 13816740 [A/G] NM_001369 DNAH5 Silent rs6889720 5 13817881 [A/G] NM_001369 DNAH5 Silent rs1445815 5 13829042 [A/G] NM_001369 DNAH5 Silent rs11738619 5 13829140 [T/G] NM_001369 DNAH5 Silent rs1348690 5 13829611 [T/C] NM_001369 DNAH5 Silent rs4547927 5 13834445 [A/G] NM_001369 DNAH5 Silent rs1596791 5 13836402 [T/C] NM_001369 DNAH5 Silent rs6868995 5 13839167 [A/G] NM_001369 DNAH5 Silent rs2053683 5 13841459 [T/G] NM_001369 DNAH5 Silent VG05S27225 5 13845070 [A/C] NM_001369 DNAH5 EXON Missense_R1716L rs17208191 5 13846802 [T/G] NM_001369 DNAH5 Silent rs895314 5 13847984 [A/G] NM_001369 DNAH5 Silent rs6554820 5 13850750 [A/G] NM_001369 DNAH5 Silent rs795526 5 13851016 [T/C] NM_001369 DNAH5 Silent rs795517 5 13852098 [T/C] NM_001369 DNAH5 Silent rs7704417 5 13862616 [T/C] NM_001369 DNAH5 Silent rs795510 5 13864189 [A/G] NM_001369 DNAH5 Silent rs6554827 5 13864728 [A/C] NM_001369 DNAH5 EXON Synonymous_R1458R rs7703349 5 13865980 [T/C] NM_001369 DNAH5 EXON Synonymous_T1384T rs797055 5 13867077 [T/C] NM_001369 DNAH5 Silent rs1445810 5 13867819 [T/C] NM_001369 DNAH5 Silent rs13156044 5 13867851 [A/G] NM_001369 DNAH5 Silent rs13159798 5 13872094 [T/C] NM_001369 DNAH5 Silent rs10061803 5 13872301 [T/C] NM_001369 DNAH5 Silent rs4701996 5 13872584 [T/G] NM_001369 DNAH5 Silent rs1445804 5 13876664 [T/C] NM_001369 DNAH5 Silent rs1445803 5 13878843 [T/G] NM_001369 DNAH5 Silent rs10057007 5 13882841 [A/G] NM_001369 DNAH5 EXON Synonymous_L1086L rs16902880 5 13882858 [T/C] NM_001369 DNAH5 EXON Missense_M1081V rs17275618 5 13887631 [A/G] NM_001369 DNAH5 Silent rs11749049 5 13889983 [A/G] NM_001369 DNAH5 Silent rs4610459 5 13892873 [A/G] NM_001369 DNAH5 Silent rs1373979 5 13893258 [T/C] NM_001369 DNAH5 Silent rs1445823 5 13900345 [A/G] NM_001369 DNAH5 EXON Synonymous_D743D rs10072677 5 13900734 [A/G] NM_001369 DNAH5 Silent rs10057950 5 13900926 [A/G] NM_001369 DNAH5 Silent rs1530498 5 13902220 [T/C] NM_001369 DNAH5 EXON Missense_T558A rs17526653 5 13905149 [T/C] NM_001369 DNAH5 Silent rs4701999 5 13905405 [T/C] NM_001369 DNAH5 Silent rs10078280 5 13906678 [T/C] NM_001369 DNAH5 Silent rs6859484 5 13909656 [T/C] NM_001369 DNAH5 Silent rs10462713 5 13909698 [T/C] NM_001369 DNAH5 Silent rs3213936 5 13913885 [A/G] NM_001369 DNAH5 EXON Synonymous_I501I rs13180591 5 13914775 [T/G] NM_001369 DNAH5 Silent rs13180613 5 13914819 [A/G] NM_001369 DNAH5 Silent rs7713700 5 13918291 [T/C] NM_001369 DNAH5 Silent rs35339484 5 13926057 [T/C] NM_001369 DNAH5 Silent rs1530496 5 13931340 [T/C] NM_001369 DNAH5 EXON Missense_G24E rs983649 5 13933125 [T/C] NM_001369 DNAH5 Silent rs16902953 5 13933416 [T/G] NM_001369 DNAH5 Silent rs1445819 5 13934119 [T/C] NM_001369 DNAH5 Silent rs17278234 5 13937476 [T/C] NM_001369 DNAH5 Silent rs10058864 5 13937803 [T/C] NM_001369 DNAH5 Silent rs10070196 5 13939830 [A/C] NM_001369 DNAH5 Silent rs16902961 5 13941978 [T/G] NM_001369 DNAH5 Silent rs339447 5 13942973 [A/G] NM_001369 DNAH5 Silent rs16902962 5 13943499 [A/G] NM_001369 DNAH5 Silent rs339445 5 13944512 [A/C] NM_001369 DNAH5 EXON Missense_H12Q rs10066164 5 13945189 [A/G] rs173090 5 13954951 [A/G] rs10050676 5 13958443 [T/G] rs2017013 5 13962264 [T/C] rs11133773 5 13964588 [A/G] rs1838697 5 13972255 [A/G] rs10036753 5 13976728 [A/G] rs339429 5 13979101 [A/G] rs339428 5 13979397 [A/G] rs339425 5 13980278 [T/C] rs339424 5 13981968 [A/C] rs10080058 5 13987061 [T/G] rs1031006 5 13987103 [A/G] rs10055489 5 13987466 [A/G] rs193154 5 13988485 [T/C] rs10045723 5 13991502 [A/G] rs7727798 5 13993530 [T/C] rs2591543 5 13993653 [T/C] rs2102443 5 13995605 [A/G] rs436457 5 14004657 [T/C] rs444601 5 14007930 [T/C] rs12517769 5 14009085 [T/C] rs429898 5 14009923 [T/C] rs2582690 5 14010420 [T/C] rs2582689 5 14013407 [A/G] rs429243 5 14020364 [T/C] rs10462717 5 14024415 [A/G] rs413338 5 14026144 [A/G] rs16903031 5 14027377 [T/C] rs1605743 5 14028309 [T/G] rs16903033 5 14035757 [A/G] rs12186457 5 14036509 [T/C] rs11133776 5 14036643 [A/G] rs6889677 5 14039647 [T/C] rs7720329 5 14041925 [A/G] rs769714 5 14046910 [T/C] rs9312860 5 14048263 [A/G] rs339956 5 14048605 [A/G] rs339951 5 14052451 [A/G] rs10223292 5 14055676 [A/G] rs13181584 5 14055801 [A/G] rs13185842 5 14056276 [T/C] rs339959 5 14058036 [A/G] rs11133779 5 14060769 [T/G] rs399712 5 14061184 [A/G] rs3849080 5 14068444 [T/C] rs7728456 5 14069408 [T/G] rs163819 5 14069439 [T/C] rs163818 5 14072057 [T/C] rs697550 5 14072453 [T/G] rs17230252 5 14074555 [A/G] rs11133781 5 14075268 [A/G] rs769732 5 14075815 [A/C] rs7708445 5 14076584 [T/C] rs392421 5 14077685 [T/C] rs384723 5 14083031 [T/C] rs11954402 5 14083816 [T/C] rs10513131 5 14087481 [A/G] rs697546 5 14087633 [A/G] rs11950716 5 14088834 [A/G] rs6881582 5 14089644 [T/C] rs9312863 5 14090114 [T/C] rs769475 5 14090392 [T/C] rs6863620 5 14093389 [A/C] rs6864072 5 14093588 [T/C] rs16903154 5 14094289 [A/G] rs706259 5 14099152 [T/C] rs386450 5 14106136 [A/G] rs425495 5 14106401 [T/C] rs183693 5 14109455 [A/C] rs185203 5 14109640 [A/G] rs11948304 5 14111048 [A/G] rs163825 5 14111261 [T/G] rs10078192 5 14116396 [A/G] rs250846 5 14116980 [T/C] rs32975 5 14118230 [T/C] rs32976 5 14118242 [A/G] rs252217 5 14118565 [T/G] rs39965 5 14119696 [A/G] rs10060689 5 14122097 [T/C] rs153191 5 14123507 [T/C] rs163823 5 14127900 [A/G] rs16903195 5 14129271 [T/C] rs388154 5 14136404 [T/C] rs11749516 5 14144117 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs6554843 5 14151799 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs17298767 5 14157376 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs152782 5 14159211 [T/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs16903243 5 14161515 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs11747048 5 14166100 [A/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs26286 5 14166402 [T/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs32593 5 14169709 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs32572 5 14172120 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs26116 5 14174279 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs12652543 5 14177235 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs28014 5 14177667 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs32340 5 14181939 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs26135 5 14185484 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs27665 5 14188019 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs26291 5 14188684 [A/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs26058 5 14192951 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs151902 5 14197566 [T/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs33005 5 14206537 [T/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs16903313 5 14211770 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs32388 5 14216900 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs149123 5 14222340 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs544588 5 14227482 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs354286 5 14235406 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs354288 5 14237265 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs16903321 5 14237570 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs11133784 5 14239606 [T/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs6876763 5 14241854 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs354283 5 14243257 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs12522960 5 14245046 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs6554850 5 14251518 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs16903338 5 14253187 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs164861 5 14262535 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs10513170 5 14263981 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs165095 5 14265371 [A/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs165094 5 14266629 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs154150 5 14275499 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs30619 5 14277686 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs7708252 5 14279073 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs2591277 5 14281126 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs773764 5 14290689 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs16903367 5 14291328 [T/G] NR_134469,NM_007118 TRIO,TRIO EXON Silent,Missense_D348E rs2434605 5 14292625 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs30633 5 14298470 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs16903375 5 14302488 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs421174 5 14303961 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs557292 5 14306905 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs42405 5 14312410 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs354919 5 14319073 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs17303923 5 14326046 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs10062003 5 14326955 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs923616 5 14329404 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs2277045 5 14330940 [T/C] NR_134469,NM_007118 TRIO,TRIO EXON Silent,Synonymous_G595G rs30623 5 14332325 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs187432 5 14334735 [A/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs7731443 5 14337891 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs247138 5 14342262 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs154159 5 14354827 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs730184 5 14360436 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs13172149 5 14363446 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs43171 5 14365895 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs16903422 5 14368659 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs13189406 5 14368975 [T/C] NR_134469,NM_007118 TRIO,TRIO EXON Silent,Synonymous_N1011N rs256417 5 14371180 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs30765 5 14375908 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs154152 5 14380324 [T/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs247137 5 14381174 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs16903450 5 14387543 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs7715916 5 14389469 [T/C] NR_134469,NM_007118 TRIO,TRIO EXON Silent,Synonymous_I1340I rs10065203 5 14393621 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs16903467 5 14395478 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs30774 5 14397238 [T/C] NR_134469,NM_007118 TRIO,TRIO EXON Silent,Synonymous_D1466D rs40278 5 14400274 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs16903474 5 14406077 [A/G] NR_134469,NM_007118 TRIO,TRIO EXON Silent,Missense_A1613T rs30608 5 14411080 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs187190 5 14415816 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs42404 5 14417929 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs16903497 5 14418419 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs10056415 5 14421026 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs32476 5 14427887 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs27761 5 14431980 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs26188 5 14432660 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs17428704 5 14434264 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs27111 5 14450135 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs26106 5 14458747 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs27100 5 14462816 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs17500759 5 14465355 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs706282 5 14472040 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs26186 5 14472626 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs6882373 5 14478601 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs26173 5 14479938 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs26098 5 14485386 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs26110 5 14491969 [A/G] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs26107 5 14498727 [A/G] NR_134469,NM_007118 TRIO,TRIO EXON Silent,Synonymous_S2770S rs3789157 5 14503893 [T/C] NR_134469,NM_007118 TRIO,TRIO Silent,Silent rs1058312 5 14509966 [A/G] NR_134469,NM_007118 TRIO,TRIO EXON Silent,Silent rs32815 5 14514308 [A/G] rs32811 5 14517076 [A/G] rs32808 5 14518208 [A/G] rs26208 5 14530993 [T/C] rs26219 5 14532534 [A/G] rs26218 5 14533529 [T/G] rs26217 5 14534994 [A/G] rs12654768 5 14537521 [T/C] rs4702038 5 14537840 [T/G] rs4701610 5 14538192 [A/C] rs6881024 5 14539821 [T/C] rs40297 5 14543201 [T/G] rs3993996 5 14545898 [T/C] rs152626 5 14553020 [T/C] rs32631 5 14561262 [A/G] rs17307347 5 14563425 [T/C] rs39968 5 14570732 [A/G] rs32635 5 14572712 [T/C] rs32636 5 14574119 [A/C] rs152624 5 14575698 [T/G] rs152642 5 14578799 [T/G] rs152621 5 14583006 [A/G] NM_019018 OTULINL Silent rs152619 5 14584695 [A/G] NM_019018 OTULINL Silent rs7734909 5 14584889 [T/C] NM_019018 OTULINL Silent rs7718540 5 14591004 [A/G] NM_019018 OTULINL Silent rs152615 5 14592979 [T/C] NM_019018 OTULINL Silent rs17248579 5 14594377 [T/C] NM_019018 OTULINL Silent rs10036723 5 14602001 [A/G] NM_019018 OTULINL Silent rs16903574 5 14610309 [G/C] NM_019018 OTULINL EXON Missense_F319L rs17296541 5 14612343 [T/C] NM_019018 OTULINL EXON Silent rs457897 5 14617857 [T/C] rs6895973 5 14621711 [A/C] rs153821 5 14628180 [T/C] rs31868 5 14637272 [T/C] rs1896783 5 14640921 [T/C] rs3853119 5 14647108 [A/G] rs25943 5 14648689 [A/C] rs456180 5 14655699 [A/G] rs1875513 5 14657062 [A/G] rs17297276 5 14667143 [T/C] NM_138348 OTULIN Silent rs16903631 5 14673696 [T/C] NM_138348 OTULIN Silent rs6892588 5 14676218 [T/C] NM_138348 OTULIN Silent rs992737 5 14677305 [A/G] NM_138348 OTULIN Silent rs11953822 5 14681711 [T/A] NM_138348 OTULIN EXON Missense_M155L rs10038170 5 14688226 [T/G] NM_138348 OTULIN Silent rs152788 5 14689707 [A/G] NM_138348 OTULIN Silent rs9312870 5 14693030 [A/G] NM_138348 OTULIN EXON Missense_N311S rs17363829 5 14693398 [T/C] NM_138348 OTULIN EXON Silent rs25951 5 14693480 [A/G] NM_138348 OTULIN EXON Silent rs25952 5 14695247 [A/C] NM_138348 OTULIN EXON Silent rs6886163 5 14697849 [A/G] NM_138348 OTULIN EXON Silent rs10065032 5 14700035 [A/G] rs258290 5 14702375 [A/G] rs27911 5 14707378 [A/G] NM_054027 ANKH EXON Silent rs25992 5 14707600 [T/C] NM_054027 ANKH EXON Silent rs10491477 5 14715140 [A/G] NM_054027,NR_046285 ANKH,LOC100130744 EXON Silent,Silent rs6883266 5 14719819 [A/G] NM_054027 ANKH Silent rs16903681 5 14741358 [T/C] NM_054027 ANKH Silent rs153932 5 14741603 [A/G] NM_054027 ANKH Silent rs187483 5 14741921 [A/C] NM_054027 ANKH Silent rs2288474 5 14741984 [T/C] NM_054027 ANKH EXON Synonymous_A321A rs149391 5 14745268 [T/C] NM_054027 ANKH Silent rs4702048 5 14750800 [A/G] NM_054027 ANKH Silent rs31934 5 14750823 [T/C] NM_054027 ANKH Silent rs2291943 5 14751400 [T/C] NM_054027 ANKH Silent rs17250963 5 14752850 [A/G] NM_054027 ANKH Silent rs10036729 5 14754571 [A/G] NM_054027 ANKH Silent rs1697124 5 14755632 [A/C] NM_054027 ANKH Silent rs152363 5 14756567 [T/C] NM_054027 ANKH Silent rs4702049 5 14759246 [T/C] NM_054027 ANKH Silent rs4701616 5 14760607 [T/C] NM_054027 ANKH Silent rs744165 5 14763707 [A/C] NM_054027 ANKH Silent rs706293 5 14764934 [A/G] NM_054027 ANKH Silent rs10513186 5 14765662 [T/C] NM_054027 ANKH Silent rs3087948 5 14768308 [T/C] NM_054027 ANKH Silent rs17251667 5 14769103 [A/G] NM_054027 ANKH EXON Synonymous_A98A rs4702052 5 14770753 [T/C] NM_054027 ANKH Silent rs17251715 5 14772245 [T/C] NM_054027 ANKH Silent rs7729478 5 14775791 [A/G] NM_054027 ANKH Silent rs9790982 5 14776585 [A/G] NM_054027 ANKH Silent rs17251763 5 14776897 [T/C] NM_054027 ANKH Silent rs9312873 5 14777799 [A/G] NM_054027 ANKH Silent rs25946 5 14787064 [A/C] NM_054027 ANKH Silent rs879253 5 14794868 [T/C] NM_054027 ANKH Silent rs258222 5 14800333 [T/C] NM_054027 ANKH Silent rs4702054 5 14804735 [T/C] NM_054027 ANKH Silent rs12514030 5 14810110 [T/G] NM_054027 ANKH Silent rs16903710 5 14814329 [T/C] NM_054027 ANKH Silent rs26304 5 14817669 [A/G] NM_054027 ANKH Silent rs10474706 5 14835061 [A/G] NM_054027 ANKH Silent rs9312874 5 14835313 [T/C] NM_054027 ANKH Silent rs826352 5 14835599 [A/G] NM_054027 ANKH Silent rs826358 5 14846372 [A/G] NM_054027 ANKH Silent rs1353258 5 14855659 [T/G] NM_054027 ANKH Silent rs2921600 5 14860723 [A/G] NM_054027 ANKH Silent rs16903719 5 14863370 [A/G] NM_054027 ANKH Silent rs10513191 5 14869666 [T/C] NM_054027 ANKH Silent rs3006069 5 14869709 [A/G] NM_054027 ANKH Silent rs835153 5 14877474 [A/G] rs835149 5 14881102 [A/G] rs2896165 5 14881275 [A/G] rs11948550 5 14883436 [A/G] rs835146 5 14884822 [A/G] rs835141 5 14888508 [T/C] rs863118 5 14890877 [T/C] rs1867676 5 14896757 [A/G] rs2441022 5 14902038 [T/C] rs3006064 5 14902964 [T/C] rs1550825 5 14908578 [A/G] rs860666 5 14908793 [T/C] rs844335 5 14913369 [T/C] rs966987 5 14917813 [T/C] rs2592019 5 14922430 [A/G] rs4702062 5 14924458 [T/C] rs835136 5 14926057 [A/G] rs728844 5 14927488 [A/C] rs10039962 5 14935018 [T/C] rs2921613 5 14943456 [T/G] rs16903741 5 14946949 [A/G] rs835102 5 14949696 [T/C] rs13353954 5 14949939 [T/C] rs12516728 5 14950952 [A/G] rs4702064 5 14952142 [A/C] rs835118 5 14956699 [A/G] rs706297 5 14960920 [A/C] rs835110 5 14962587 [T/C] rs12516899 5 14968345 [A/G] rs835092 5 14970328 [T/C] rs10037304 5 14973914 [A/G] rs835069 5 14984116 [T/C] rs1992707 5 14986700 [T/C] rs835061 5 14989810 [T/C] rs2402022 5 14989823 [T/C] rs3006071 5 14995390 [A/G] rs9312876 5 15001929 [T/C] rs6867275 5 15007802 [A/C] rs10513195 5 15019660 [A/G] rs7727670 5 15022112 [T/G] rs9688328 5 15024160 [A/G] rs9687159 5 15024237 [T/C] rs735243 5 15039327 [A/G] rs30539 5 15044842 [A/G] rs30538 5 15045871 [A/G] rs16903801 5 15081127 [T/C] rs2121183 5 15082673 [A/G] rs32466 5 15087791 [T/C] rs32447 5 15117438 [A/G] rs32443 5 15118799 [A/G] rs1446037 5 15123737 [T/C] rs1446040 5 15124021 [A/G] rs251544 5 15130618 [A/G] rs2455489 5 15143511 [A/G] rs2455488 5 15151678 [A/G] rs301076 5 15155515 [T/G] rs1500232 5 15162646 [T/C] rs7721868 5 15168945 [A/G] rs10074693 5 15181322 [A/G] rs7723367 5 15194140 [A/C] NR_109944 LINC02149 Silent rs10036487 5 15203379 [A/G] NR_109944 LINC02149 Silent rs2166391 5 15211107 [T/C] NR_109944 LINC02149 Silent rs6554873 5 15235092 [A/G] NR_109944 LINC02149 Silent rs10073250 5 15268978 [T/C] rs7707492 5 15278843 [A/G] rs17703484 5 15298906 [T/C] rs7717159 5 15310572 [A/G] rs303345 5 15313022 [T/C] rs6899293 5 15317509 [A/G] rs1457155 5 15322777 [T/C] rs1447278 5 15327830 [A/G] rs11954098 5 15329810 [T/C] rs303354 5 15333012 [T/C] rs7713373 5 15337921 [A/G] rs10059739 5 15347072 [A/G] rs9312883 5 15356068 [T/C] rs1447276 5 15364484 [A/G] rs303352 5 15366156 [T/C] rs2271718 5 15390648 [T/C] rs7709371 5 15391944 [A/G] rs2402152 5 15393536 [T/C] rs10475063 5 15416477 [A/G] rs188592 5 15418957 [A/C] rs304562 5 15432384 [A/G] rs304586 5 15447939 [T/C] rs16903877 5 15476181 [A/C] rs35291709 5 15498918 [A/G] rs16903899 5 15519917 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs10462596 5 15530640 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs581957 5 15548576 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs4144522 5 15550687 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs496319 5 15551178 [A/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs983889 5 15555486 [T/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs969351 5 15567629 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs1429036 5 15571736 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs9312894 5 15576756 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs1549696 5 15580207 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs1978633 5 15582005 [T/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs7706439 5 15586293 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs1429040 5 15589171 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs1025327 5 15597087 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs1019810 5 15598629 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs6891138 5 15601489 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs13170478 5 15602644 [T/C] NM_012304,NM_001278317,NR_109945 FBXL7,FBXL7,CTD-2350J17.1 Silent,Silent,Silent rs4510586 5 15604978 [T/C] NM_012304,NM_001278317,NR_109945 FBXL7,FBXL7,CTD-2350J17.1 Silent,Silent,Silent rs16867529 5 15613657 [A/G] NM_012304,NM_001278317,NR_109945 FBXL7,FBXL7,CTD-2350J17.1 Silent,Silent,Silent rs7704791 5 15632099 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs17601702 5 15633377 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs7720476 5 15635087 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs4587075 5 15639915 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs6878131 5 15646811 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs6878966 5 15647084 [T/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs6898779 5 15648296 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs17703964 5 15650140 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs6897885 5 15651836 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs1127792 5 15654479 [T/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs13185548 5 15655056 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs17647599 5 15659551 [A/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs11743317 5 15660058 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs12652447 5 15674635 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs34341354 5 15678556 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs16867538 5 15680744 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs17523624 5 15684270 [T/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs12655356 5 15685126 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs17704215 5 15690455 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs4702100 5 15694620 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs17523908 5 15696499 [T/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs4701641 5 15697062 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs11747715 5 15699997 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs7733676 5 15702469 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs17602350 5 15707132 [T/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs7704277 5 15713072 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs4374757 5 15719350 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs4702103 5 15719942 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs16867617 5 15720106 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs11748790 5 15723633 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs4133004 5 15728229 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs10039391 5 15729889 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs6877517 5 15734275 [A/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs4293917 5 15742599 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs2937075 5 15747814 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs924455 5 15747866 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs1015669 5 15750881 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs2937074 5 15751645 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs2937076 5 15752604 [T/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs2133761 5 15753722 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs1394657 5 15763218 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs13170409 5 15764650 [A/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs10520823 5 15766072 [T/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs2937072 5 15770553 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs10462723 5 15771101 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs1505034 5 15774034 [T/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs2055624 5 15777817 [A/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs1505039 5 15779815 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs11953097 5 15781244 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs16867713 5 15783500 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs16867730 5 15789739 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs10520825 5 15790676 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs416952 5 15808138 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs6896361 5 15815433 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs10050940 5 15819269 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs10053578 5 15821161 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs183759 5 15821793 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs257752 5 15823365 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs13158449 5 15832573 [T/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs257768 5 15843597 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs257744 5 15850418 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs10061247 5 15850728 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs7723811 5 15853939 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs6894588 5 15861183 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs6420027 5 15870300 [A/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs7715223 5 15900124 [A/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs6897647 5 15904024 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs6878591 5 15913112 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs6883363 5 15913562 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs13153362 5 15919799 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs6892388 5 15921693 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs3935971 5 15924697 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs12517809 5 15925524 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs13185525 5 15925573 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 Silent,Silent rs6554906 5 15937910 [T/C] NM_012304,NM_001278317 FBXL7,FBXL7 EXON Silent,Silent rs3810847 5 15938553 [A/G] NM_012304,NM_001278317 FBXL7,FBXL7 EXON Silent,Silent rs7718315 5 15940600 [T/C] rs982484 5 15943683 [A/G] rs1354182 5 15949793 [A/G] rs1502024 5 15960831 [T/C] rs7735201 5 15965000 [T/C] rs7727759 5 15968662 [T/G] rs250488 5 15973231 [T/C] rs250498 5 15992699 [T/G] rs32826 5 15992984 [T/C] rs32824 5 15993449 [T/G] rs1393268 5 15998273 [T/C] rs250497 5 16000639 [A/C] rs168747 5 16010717 [A/C] rs1502027 5 16016736 [A/G] rs10520833 5 16017401 [A/G] rs11955061 5 16021223 [T/C] rs1393266 5 16022694 [T/C] rs16867959 5 16024011 [T/C] rs1566654 5 16027376 [T/C] rs974847 5 16027427 [T/C] rs4701647 5 16030905 [A/G] rs7707378 5 16034119 [T/G] rs6866525 5 16034232 [T/C] rs6876369 5 16035369 [A/G] rs32199 5 16037234 [A/G] rs1039443 5 16038102 [T/C] rs1823075 5 16044383 [T/G] rs11133827 5 16048639 [A/G] rs7701823 5 16054101 [T/C] rs16868026 5 16059968 [T/G] rs6861364 5 16080658 [A/G] NM_001102562 MARCH11 Silent rs16868078 5 16080712 [T/C] NM_001102562 MARCH11 Silent rs1992719 5 16081670 [T/C] NM_001102562 MARCH11 Silent rs7736562 5 16088262 [T/C] NM_001102562 MARCH11 Silent rs9312902 5 16088655 [T/G] NM_001102562 MARCH11 Silent rs10043833 5 16089344 [T/C] NM_001102562 MARCH11 Silent rs10038404 5 16097008 [A/G] NM_001102562 MARCH11 Silent rs10475072 5 16103046 [T/C] NM_001102562 MARCH11 Silent rs6890898 5 16108974 [T/C] NM_001102562 MARCH11 Silent rs6554912 5 16110431 [A/G] NM_001102562 MARCH11 Silent rs11960118 5 16119494 [A/G] NM_001102562 MARCH11 Silent rs17649190 5 16128234 [A/G] NM_001102562 MARCH11 Silent rs344701 5 16142399 [A/G] NM_001102562 MARCH11 Silent rs344734 5 16158739 [T/C] NM_001102562 MARCH11 Silent rs7707491 5 16182201 [A/G] NR_149044 LOC401176 Silent rs237065 5 16182788 [A/G] NR_149044 LOC401176 Silent rs342559 5 16184180 [A/G] NR_149044 LOC401176 EXON Silent rs342563 5 16187424 [A/G] rs344739 5 16195381 [T/C] rs344720 5 16205201 [A/G] rs16868188 5 16216230 [A/G] rs17611228 5 16217387 [T/C] rs4368728 5 16221678 [A/G] rs995765 5 16224737 [T/C] rs12652713 5 16228197 [A/G] rs6866941 5 16231128 [T/C] rs4701655 5 16237236 [A/G] rs11750406 5 16238094 [T/G] rs10038426 5 16242706 [A/G] rs12187958 5 16245534 [T/C] rs7706076 5 16246505 [T/C] rs7715586 5 16253763 [T/C] rs11133838 5 16254310 [A/G] rs16868296 5 16257125 [A/G] rs4702133 5 16261195 [A/G] rs17705925 5 16261338 [A/G] rs10068746 5 16265015 [A/C] rs11133841 5 16265505 [A/G] rs11739184 5 16270044 [A/G] rs2967940 5 16278279 [T/C] rs831657 5 16286973 [A/G] rs831659 5 16287107 [T/C] rs1371974 5 16287578 [A/G] rs6874136 5 16289065 [T/C] rs996317 5 16295122 [T/C] rs10052415 5 16306370 [A/G] rs3907091 5 16342078 [T/C] rs12656374 5 16346572 [T/C] rs955205 5 16347660 [A/C] rs3849096 5 16366460 [A/C] rs16868502 5 16366540 [A/G] rs10065052 5 16366662 [T/C] rs16868503 5 16367508 [T/C] rs16868520 5 16373968 [A/G] NR_104625 LINC02150 Silent rs29965 5 16374042 [T/C] NR_104625 LINC02150 Silent rs6885471 5 16379041 [A/G] NR_104625 LINC02150 Silent rs17649734 5 16379078 [A/G] NR_104625 LINC02150 Silent rs186758 5 16381553 [T/C] NR_104625 LINC02150 Silent rs11133844 5 16383215 [A/G] NR_104625 LINC02150 Silent rs831179 5 16384646 [A/G] NR_104625 LINC02150 Silent rs17706248 5 16385915 [T/C] NR_104625 LINC02150 Silent rs4702142 5 16393546 [T/C] NR_104625 LINC02150 Silent rs32141 5 16408600 [A/G] NR_104625 LINC02150 Silent rs12187814 5 16410418 [T/C] NR_104625 LINC02150 Silent rs29948 5 16411810 [T/C] NR_104625 LINC02150 Silent rs29949 5 16413014 [A/C] NR_104625 LINC02150 Silent rs258879 5 16418829 [A/G] NR_104625 LINC02150 Silent rs168934 5 16419249 [T/C] NR_104625 LINC02150 Silent rs258881 5 16427050 [T/C] NR_104625 LINC02150 Silent rs12186886 5 16437581 [T/C] NR_104625 LINC02150 EXON Silent rs258884 5 16439153 [A/G] NR_104625 LINC02150 Silent rs466205 5 16451188 [T/C] rs27454 5 16451246 [T/G] rs27883 5 16454953 [T/C] NM_033414 ZNF622 Silent rs27452 5 16455126 [A/G] NM_033414 ZNF622 Silent rs10520840 5 16456131 [T/C] NM_033414 ZNF622 Silent rs16868635 5 16467413 [A/G] rs13155194 5 16469415 [A/G] rs149511 5 16469593 [T/C] rs10520841 5 16472881 [T/C] rs26016 5 16473838 [T/C] NM_001034850,NM_019000 RETREG1,RETREG1 EXON Silent,Silent rs2401881 5 16474258 [T/C] NM_001034850,NM_019000 RETREG1,RETREG1 EXON Silent,Silent rs32147 5 16474644 [T/G] NM_001034850,NM_019000 RETREG1,RETREG1 EXON Silent,Silent rs162849 5 16478120 [A/G] NM_001034850,NM_019000 RETREG1,RETREG1 Silent,Silent rs162848 5 16478200 [A/G] NM_001034850,NM_019000 RETREG1,RETREG1 EXON Synonymous_D272D,Synonymous_D131D rs16868675 5 16481185 [A/G] NM_001034850,NM_019000 RETREG1,RETREG1 EXON Synonymous_C201C,Synonymous_C60C rs4702146 5 16487697 [T/C] NM_001034850,NM_019000 RETREG1,RETREG1 Silent,Silent rs12519984 5 16488673 [A/G] NM_001034850,NM_019000 RETREG1,RETREG1 Silent,Silent rs12187267 5 16491052 [A/G] NM_001034850,NM_019000 RETREG1,RETREG1 Silent,Silent rs332807 5 16500790 [A/G] NM_001034850,NM_019000 RETREG1,RETREG1 Silent,Silent rs4702147 5 16503147 [A/G] NM_001034850,NM_019000 RETREG1,RETREG1 Silent,Silent rs4702149 5 16504763 [T/C] NM_001034850,NM_019000 RETREG1,RETREG1 Silent,Silent rs16868696 5 16505707 [T/C] NM_001034850,NM_019000 RETREG1,RETREG1 Silent,Silent rs332811 5 16508674 [A/G] NM_001034850,NM_019000 RETREG1,RETREG1 Silent,Silent rs33684 5 16508898 [T/C] NM_001034850,NM_019000 RETREG1,RETREG1 EXON Silent,Silent rs33685 5 16509336 [A/G] NM_001034850 RETREG1 Silent rs334470 5 16512364 [A/G] NM_001034850 RETREG1 Silent rs4702150 5 16514269 [T/G] NM_001034850 RETREG1 Silent rs16868716 5 16515716 [A/G] NM_001034850 RETREG1 Silent rs149263 5 16521575 [T/C] NM_001034850 RETREG1 Silent rs163282 5 16522125 [T/C] NM_001034850 RETREG1 Silent rs17540822 5 16525790 [A/G] NM_001034850 RETREG1 Silent rs334493 5 16528257 [T/C] NM_001034850 RETREG1 Silent rs2028843 5 16528603 [T/C] NM_001034850 RETREG1 Silent rs334485 5 16529595 [A/G] NM_001034850 RETREG1 Silent rs12188529 5 16529754 [A/G] NM_001034850 RETREG1 Silent rs334483 5 16530343 [A/G] NM_001034850 RETREG1 Silent rs1551050 5 16533551 [A/G] NM_001034850 RETREG1 Silent rs13180554 5 16535341 [T/C] NM_001034850 RETREG1 Silent rs6870158 5 16537473 [T/G] NM_001034850 RETREG1 Silent rs10053126 5 16540742 [A/G] NM_001034850 RETREG1 Silent rs10053236 5 16540912 [A/G] NM_001034850 RETREG1 Silent rs12187879 5 16547911 [T/C] NM_001034850 RETREG1 Silent rs1991471 5 16556601 [T/C] NM_001034850 RETREG1 Silent rs1240649 5 16559581 [A/G] NM_001034850 RETREG1 Silent rs31289 5 16560819 [T/C] NM_001034850 RETREG1 Silent rs10035580 5 16564901 [T/G] NM_001034850 RETREG1 Silent rs2560828 5 16566212 [T/C] NM_001034850 RETREG1 Silent rs17613128 5 16569071 [T/G] NM_001034850 RETREG1 Silent rs6859637 5 16569388 [A/G] NM_001034850 RETREG1 Silent rs2560826 5 16578135 [T/C] NM_001034850 RETREG1 Silent rs154244 5 16580567 [A/G] NM_001034850 RETREG1 Silent rs2451855 5 16584227 [A/G] NM_001034850 RETREG1 Silent rs431154 5 16585183 [T/C] NM_001034850 RETREG1 Silent rs2637146 5 16585512 [A/C] NM_001034850 RETREG1 Silent rs6887031 5 16586718 [A/G] NM_001034850 RETREG1 Silent rs2451851 5 16589850 [T/C] NM_001034850 RETREG1 Silent rs2592037 5 16605738 [T/G] NM_001034850 RETREG1 Silent rs12521478 5 16607196 [T/C] NM_001034850 RETREG1 Silent rs17541315 5 16608454 [A/G] NM_001034850 RETREG1 Silent rs12516207 5 16608493 [T/C] NM_001034850 RETREG1 Silent rs1863997 5 16610057 [A/G] NM_001034850 RETREG1 Silent rs35002 5 16616373 [T/C] NM_001034850,NR_109946 RETREG1,LOC101929524 EXON Silent,Silent rs35004 5 16617903 [A/C] NR_109946 LOC101929524 Silent rs35005 5 16618920 [T/G] NR_109946 LOC101929524 Silent rs256884 5 16624190 [A/C] NR_109946 LOC101929524 Silent rs10520842 5 16626717 [T/G] NR_109946 LOC101929524 Silent rs6861112 5 16627761 [A/G] NR_109946 LOC101929524 Silent rs257174 5 16628511 [T/C] NR_109946 LOC101929524 Silent rs257172 5 16631653 [A/G] rs257170 5 16631835 [A/G] rs386845 5 16642272 [T/G] rs6892658 5 16645335 [T/G] rs12110160 5 16650908 [A/C] rs379803 5 16654960 [T/G] rs388887 5 16658524 [A/G] rs252369 5 16659864 [A/G] rs257159 5 16660145 [T/G] rs7722385 5 16661282 [T/C] rs153202 5 16661569 [A/G] rs13537 5 16662297 [A/G] NM_012334 MYO10 EXON Silent rs26742 5 16664769 [A/G] NM_012334 MYO10 EXON Silent rs27431 5 16670618 [T/C] NM_012334 MYO10 Silent rs26745 5 16673685 [T/C] NM_012334 MYO10 Silent rs25901 5 16673975 [G/C] NM_012334 MYO10 EXON Missense_S1663T rs35580 5 16679966 [T/C] NM_012334 MYO10 Silent rs2288433 5 16680772 [T/C] NM_012334 MYO10 Silent rs26759 5 16684807 [A/G] NM_012334 MYO10 Silent rs6881621 5 16687522 [T/C] NM_012334 MYO10 Silent rs31313 5 16690754 [T/C] NM_012334 MYO10 Silent rs7733988 5 16693918 [A/G] NM_012334 MYO10 Silent rs25910 5 16694309 [T/C] NM_012334 MYO10 Silent rs256930 5 16699512 [A/G] NM_012334 MYO10 Silent rs149110 5 16701717 [T/C] NM_012334 MYO10 EXON Synonymous_R929R rs3849106 5 16705915 [T/C] NM_012334 MYO10 Silent rs25912 5 16706530 [T/C] NM_012334 MYO10 Silent rs2288442 5 16710763 [T/C] NM_012334 MYO10 Silent rs26740 5 16711087 [T/C] NM_012334 MYO10 EXON Missense_R700Q rs31299 5 16713465 [T/C] NM_012334 MYO10 Silent rs40979 5 16721306 [A/C] NM_012334 MYO10 Silent rs152726 5 16724163 [T/C] NM_012334 MYO10 Silent rs10051970 5 16732052 [T/C] NM_012334 MYO10 Silent rs11133857 5 16737513 [A/G] NM_012334 MYO10 Silent rs10051930 5 16741099 [A/C] NM_012334 MYO10 Silent rs6896958 5 16746784 [A/G] NM_012334 MYO10 Silent rs6890128 5 16751179 [A/C] NM_012334 MYO10 Silent rs11958235 5 16752986 [T/G] NM_012334 MYO10 Silent rs17429731 5 16755049 [T/C] NM_012334 MYO10 Silent rs250340 5 16758569 [T/C] NM_012334 MYO10 Silent rs16869106 5 16759034 [A/G] NM_012334 MYO10 Silent rs31509 5 16760970 [A/G] NM_012334 MYO10 Silent rs31511 5 16762646 [T/C] NM_012334 MYO10 Silent rs39900 5 16763908 [A/G] NM_012334 MYO10 Silent rs250341 5 16764334 [T/C] NM_012334 MYO10 Silent rs2561231 5 16764644 [T/C] NM_012334 MYO10 Silent rs10062159 5 16768418 [A/C] NM_012334 MYO10 Silent rs11750538 5 16769273 [A/G] NM_012334 MYO10 EXON Missense_R324W rs7703315 5 16770452 [T/G] NM_012334 MYO10 Silent rs10053767 5 16771640 [A/G] NM_012334 MYO10 Silent rs4702171 5 16772976 [A/G] NM_012334 MYO10 Silent rs25908 5 16776951 [A/G] NM_012334 MYO10 Silent rs12520877 5 16778415 [A/G] NM_012334 MYO10 Silent rs12520918 5 16778598 [A/G] NM_012334 MYO10 Silent rs6870170 5 16780640 [T/G] NM_012334 MYO10 EXON Missense_E273D rs25906 5 16783021 [A/C] NM_012334 MYO10 Silent rs4702172 5 16783711 [T/C] NM_012334 MYO10 Silent rs11133859 5 16783993 [A/G] NM_012334 MYO10 Silent rs25904 5 16784019 [A/G] NM_012334 MYO10 Silent rs6877325 5 16785604 [T/C] NM_012334 MYO10 Silent rs250345 5 16788851 [A/G] NM_012334 MYO10 Silent rs250348 5 16790200 [A/C] NM_012334 MYO10 Silent rs153409 5 16790483 [T/C] NM_012334 MYO10 Silent rs250356 5 16793089 [A/C] NM_012334 MYO10 Silent rs6888120 5 16793151 [A/G] NM_012334 MYO10 Silent rs253365 5 16797415 [T/C] NM_012334 MYO10 Silent rs7717298 5 16799341 [T/C] NM_012334 MYO10 Silent rs40020 5 16804121 [A/G] NM_012334 MYO10 Silent rs1872004 5 16807786 [A/C] NM_012334 MYO10 Silent rs17651095 5 16810263 [A/C] NM_012334 MYO10 Silent rs11745637 5 16813881 [A/C] NM_012334 MYO10 Silent rs12188582 5 16818363 [A/G] NM_012334 MYO10 Silent rs890825 5 16819642 [A/G] NM_012334 MYO10 Silent rs7726872 5 16820505 [A/C] NM_012334 MYO10 Silent rs17651165 5 16820769 [T/C] NM_012334 MYO10 Silent rs31505 5 16834568 [T/C] NM_012334 MYO10 Silent rs9312937 5 16836005 [T/C] NM_012334 MYO10 Silent rs17707735 5 16840145 [A/G] NM_012334 MYO10 Silent rs253336 5 16840641 [A/C] NM_012334 MYO10 Silent rs2560861 5 16841399 [T/C] NM_012334 MYO10 Silent rs31499 5 16843108 [A/G] NM_012334 MYO10 Silent rs716555 5 16844859 [T/C] NM_012334 MYO10 Silent rs10213765 5 16848200 [T/C] NM_012334 MYO10 Silent rs9312938 5 16850125 [T/C] NM_012334 MYO10 Silent rs17614174 5 16862419 [T/C] NM_012334 MYO10 Silent rs891163 5 16862998 [A/G] NM_012334 MYO10 Silent rs17707882 5 16864632 [T/C] NM_012334 MYO10 Silent rs2625210 5 16875690 [T/C] NM_012334 MYO10 Silent rs2562338 5 16876479 [A/G] NM_012334 MYO10 Silent rs7356599 5 16877640 [T/C] NM_012334 MYO10 Silent rs17707947 5 16877744 [T/C] NM_012334 MYO10 EXON Missense_V32I rs7711618 5 16878237 [A/G] NM_012334 MYO10 Silent rs166225 5 16880404 [A/G] NM_012334 MYO10 Silent rs254833 5 16880460 [T/C] NM_012334 MYO10 Silent rs153706 5 16882242 [A/G] NM_012334 MYO10 Silent rs2560851 5 16887383 [T/C] NM_012334 MYO10 Silent rs17651616 5 16887414 [T/C] NM_012334 MYO10 Silent rs2562343 5 16892404 [A/G] NM_012334 MYO10 Silent rs17651643 5 16892438 [A/G] NM_012334 MYO10 Silent rs173789 5 16895512 [T/G] NM_012334 MYO10 Silent rs253482 5 16897446 [T/C] NM_012334 MYO10 Silent rs253483 5 16897597 [T/C] NM_012334 MYO10 Silent rs2562350 5 16897799 [T/G] NM_012334 MYO10 Silent rs10520846 5 16901752 [A/G] NM_012334 MYO10 Silent rs10520847 5 16903718 [A/C] NM_012334 MYO10 Silent rs153709 5 16904555 [A/C] NM_012334 MYO10 Silent rs13176126 5 16905100 [A/C] NM_012334 MYO10 Silent rs4702182 5 16906913 [A/G] NM_012334 MYO10 Silent rs29448 5 16907538 [A/C] NM_012334 MYO10 Silent rs29452 5 16910605 [A/C] NM_012334 MYO10 Silent rs152342 5 16910789 [A/G] NM_012334 MYO10 Silent rs16869235 5 16912847 [A/G] NM_012334 MYO10 Silent rs29454 5 16913578 [T/C] NM_012334 MYO10 Silent rs29455 5 16913719 [T/C] NM_012334 MYO10 Silent rs17614462 5 16913855 [A/G] NM_012334 MYO10 Silent rs39896 5 16914516 [A/G] NM_012334 MYO10 Silent rs13178744 5 16920867 [A/G] NM_012334 MYO10 Silent rs249123 5 16921494 [A/C] NM_012334 MYO10 Silent rs2434960 5 16923843 [A/G] NM_012334 MYO10 Silent rs17651767 5 16924422 [T/G] NM_012334 MYO10 Silent rs2625177 5 16924531 [A/C] NM_012334 MYO10 Silent rs31454 5 16930761 [A/C] NM_012334 MYO10 Silent rs31457 5 16932148 [A/G] NM_012334 MYO10 Silent rs3866217 5 16940614 [T/C] rs10061139 5 16945823 [A/G] rs2402335 5 16948041 [T/C] rs12653955 5 16949845 [T/C] rs249116 5 16952807 [T/C] rs249131 5 16961453 [A/C] rs17708295 5 16969440 [A/G] rs6885799 5 16980857 [A/C] rs1549672 5 16986171 [T/C] rs10076041 5 16989839 [T/C] rs6877901 5 16991693 [A/C] rs11749259 5 16993278 [A/G] rs2018015 5 16993868 [A/G] rs4129967 5 17000364 [T/G] rs6870542 5 17003017 [T/C] rs6870564 5 17003085 [A/G] rs4360041 5 17005751 [T/G] rs4374758 5 17018543 [T/C] rs6859425 5 17023701 [T/C] rs6866220 5 17025067 [A/G] rs11949558 5 17030640 [A/G] rs4701679 5 17049441 [T/C] rs6862915 5 17059369 [T/C] rs13178476 5 17063654 [A/G] rs17708415 5 17069833 [T/C] rs12519524 5 17078227 [T/G] rs12519960 5 17085379 [A/G] rs17652001 5 17086303 [A/G] rs6880043 5 17092491 [A/C] rs2624435 5 17095269 [A/G] rs644358 5 17107465 [A/C] rs297177 5 17114476 [T/C] rs297178 5 17114626 [A/G] rs1351583 5 17116221 [T/C] rs1032763 5 17118930 [T/C] rs7704060 5 17124559 [T/C] rs297205 5 17126149 [A/G] rs297206 5 17126682 [A/G] rs2896245 5 17129725 [T/C] rs167214 5 17137175 [A/G] NR_027253 BASP1-AS1 Silent rs9312946 5 17142051 [A/G] NR_027253 BASP1-AS1 Silent rs1875538 5 17145198 [A/C] NR_027253 BASP1-AS1 Silent rs587977 5 17148236 [T/C] NR_027253 BASP1-AS1 Silent rs2624417 5 17148318 [A/C] NR_027253 BASP1-AS1 Silent rs683580 5 17155359 [A/G] NR_027253 BASP1-AS1 Silent rs297182 5 17158041 [T/C] NR_027253 BASP1-AS1 Silent rs10462742 5 17159786 [T/C] NR_027253 BASP1-AS1 Silent rs13175997 5 17160258 [T/C] NR_027253 BASP1-AS1 Silent rs641871 5 17163899 [A/G] NR_027253 BASP1-AS1 Silent rs16869525 5 17167802 [A/C] NR_027253 BASP1-AS1 Silent rs686204 5 17168217 [A/G] NR_027253 BASP1-AS1 Silent rs2402350 5 17172790 [T/C] NR_027253 BASP1-AS1 Silent rs4602628 5 17181964 [T/C] NR_027253 BASP1-AS1 Silent rs638191 5 17183851 [A/C] NR_027253 BASP1-AS1 Silent rs177053 5 17183891 [A/C] NR_027253 BASP1-AS1 Silent rs297197 5 17185433 [T/C] NR_027253 BASP1-AS1 Silent rs2046255 5 17191486 [T/C] NR_027253 BASP1-AS1 Silent rs585991 5 17193633 [T/C] NR_027253 BASP1-AS1 Silent rs586087 5 17193708 [T/G] NR_027253 BASP1-AS1 Silent rs586971 5 17193856 [T/C] NR_027253 BASP1-AS1 Silent rs587887 5 17194063 [T/C] NR_027253 BASP1-AS1 Silent rs2929711 5 17194395 [A/G] NR_027253 BASP1-AS1 Silent rs1542598 5 17197505 [T/C] NR_027253 BASP1-AS1 Silent rs2731792 5 17211545 [T/C] NR_027253 BASP1-AS1 Silent rs2929726 5 17211649 [A/G] NR_027253 BASP1-AS1 Silent rs10474727 5 17216736 [A/G] NR_027253 BASP1-AS1 EXON Silent rs1482344 5 17221016 [A/G] NM_001271606,NM_006317 BASP1,BASP1 Silent,Silent rs2291236 5 17228908 [T/C] NM_001271606,NM_006317 BASP1,BASP1 Silent,Silent rs2962372 5 17232818 [A/G] NM_001271606,NM_006317 BASP1,BASP1 Silent,Silent rs12716119 5 17234794 [A/G] NM_001271606,NM_006317 BASP1,BASP1 Silent,Silent rs298528 5 17235998 [T/C] NM_001271606,NM_006317 BASP1,BASP1 Silent,Silent rs10053617 5 17247021 [T/G] NM_001271606,NM_006317 BASP1,BASP1 Silent,Silent rs953431 5 17249420 [A/G] NM_001271606,NM_006317 BASP1,BASP1 Silent,Silent rs11133892 5 17255026 [A/G] NM_001271606,NM_006317 BASP1,BASP1 Silent,Silent rs2937754 5 17255803 [T/C] NM_001271606,NM_006317 BASP1,BASP1 Silent,Silent rs6892031 5 17261365 [T/C] NM_001271606,NM_006317 BASP1,BASP1 Silent,Silent rs1500508 5 17264096 [A/G] NM_001271606,NM_006317 BASP1,BASP1 Silent,Silent rs298592 5 17264914 [T/C] NM_001271606,NM_006317 BASP1,BASP1 Silent,Silent rs298563 5 17276986 [T/C] rs177110 5 17283265 [A/G] rs298577 5 17285297 [A/C] rs17615463 5 17289965 [T/C] rs12523570 5 17296342 [A/G] rs298564 5 17298852 [A/G] rs16869688 5 17306610 [T/C] rs298512 5 17306790 [T/C] rs298510 5 17316993 [A/C] rs7707380 5 17319116 [T/C] rs10475103 5 17321707 [A/G] rs298556 5 17327540 [T/C] rs1995289 5 17328269 [T/C] rs298552 5 17333950 [T/C] rs10866522 5 17347706 [T/C] rs2650944 5 17351275 [T/G] rs4702207 5 17358730 [T/C] rs2036851 5 17361908 [A/G] rs177108 5 17366805 [T/C] rs299384 5 17368172 [A/G] rs298529 5 17369216 [A/G] rs16869742 5 17375767 [A/C] rs6876143 5 17380270 [A/G] NR_033975 LINC02111 EXON Silent rs1877128 5 17381321 [T/C] NR_033975 LINC02111 Silent rs7729265 5 17391377 [T/C] rs1397576 5 17400274 [A/G] rs7712657 5 17401187 [T/C] rs2457769 5 17403095 [A/G] rs2173757 5 17403618 [A/G] rs2173758 5 17403662 [T/C] rs2173759 5 17404483 [A/G] NR_134275,NR_134274 LINC02217,LINC02217 Silent,Silent rs2036339 5 17404549 [A/G] NR_134275,NR_134274 LINC02217,LINC02217 Silent,Silent rs10475105 5 17409558 [A/G] NR_134275,NR_134274 LINC02217,LINC02217 Silent,Silent rs11133899 5 17409998 [A/C] NR_134275,NR_134274 LINC02217,LINC02217 Silent,Silent rs17658764 5 17415197 [A/G] NR_134275,NR_134274 LINC02217,LINC02217 Silent,Silent rs2457761 5 17418256 [T/C] NR_134275,NR_134274 LINC02217,LINC02217 Silent,Silent rs2457762 5 17418330 [T/C] NR_134275,NR_134274 LINC02217,LINC02217 Silent,Silent rs2941677 5 17421158 [T/G] NR_134275,NR_134274 LINC02217,LINC02217 Silent,Silent rs6868322 5 17422915 [T/C] NR_134275,NR_134274 LINC02217,LINC02217 Silent,Silent rs1553847 5 17430052 [A/G] NR_134275,NR_134274 LINC02217,LINC02217 Silent,Silent rs7718456 5 17430238 [T/G] NR_134275,NR_134274 LINC02217,LINC02217 Silent,Silent rs2459791 5 17434249 [T/C] NR_134275,NR_134274 LINC02217,LINC02217 Silent,Silent rs2459830 5 17442045 [T/C] rs7706512 5 17443654 [A/G] rs10057009 5 17445833 [A/G] NR_134271,NR_134270 LINC02218,LINC02218 EXON Silent,Silent rs2459826 5 17453016 [A/G] NR_134270 LINC02218 Silent rs6863447 5 17455566 [T/C] NR_134270 LINC02218 Silent rs4318775 5 17457266 [T/G] NR_134270 LINC02218 Silent rs2459822 5 17477812 [T/C] NR_134270 LINC02218 EXON Silent rs2459821 5 17479389 [A/G] NR_134270 LINC02218 Silent rs1510960 5 17484038 [A/G] NR_134270 LINC02218 EXON Silent rs11133906 5 17489383 [A/G] rs2402396 5 17509888 [A/C] rs1848990 5 17512311 [T/C] rs13158336 5 17599577 [T/C] rs6897250 5 17625744 [T/C] rs6862327 5 17642516 [A/G] rs1995849 5 17656351 [T/G] rs4530802 5 17665529 [A/G] rs7718648 5 17697085 [A/G] rs13190307 5 17710478 [T/G] rs6865140 5 17719837 [A/G] rs10805605 5 17727088 [T/G] rs6896861 5 17727683 [A/G] rs6450962 5 17730304 [A/G] rs1514866 5 17732806 [A/G] rs6894996 5 17734581 [T/G] rs2379265 5 17735395 [A/G] rs7445769 5 17738703 [T/C] rs10461717 5 17739449 [A/G] rs1514855 5 17745762 [T/C] rs1514857 5 17746787 [T/C] rs11959046 5 17761225 [A/G] rs6451281 5 17762135 [T/G] rs1913602 5 17764015 [T/C] rs1514872 5 17764650 [T/C] rs16887628 5 17770373 [A/G] rs6864067 5 17776869 [A/G] rs7737273 5 17780459 [T/G] rs10941533 5 17784226 [T/C] rs10941538 5 17784552 [T/C] rs11960755 5 17790562 [T/C] rs7714225 5 17790612 [T/C] rs11958964 5 17791030 [A/G] rs1822399 5 17791844 [T/G] rs11738744 5 17794035 [A/G] rs7713161 5 17796513 [A/G] rs10064153 5 17802524 [A/C] rs971716 5 17802864 [T/C] rs971715 5 17803067 [A/G] rs6876885 5 17803270 [T/G] rs9637792 5 17804005 [A/G] rs10462045 5 17804346 [T/C] rs9292873 5 17805883 [A/G] rs16887560 5 17806954 [T/C] rs16887557 5 17807202 [A/G] rs17710639 5 17808002 [A/C] NR_134287,NR_134286 LINC02223,LINC02223 Silent,Silent rs13166250 5 17809455 [A/G] NR_134287,NR_134286 LINC02223,LINC02223 Silent,Silent rs6881131 5 17809984 [A/G] NR_134287,NR_134286 LINC02223,LINC02223 Silent,Silent rs7341145 5 17818316 [T/C] NR_134286 LINC02223 Silent rs6872569 5 17819987 [T/C] NR_134286 LINC02223 Silent rs11960567 5 17820084 [T/C] NR_134286 LINC02223 Silent rs1513088 5 17820745 [T/C] NR_134286 LINC02223 Silent rs6859316 5 17828116 [T/G] NR_134286 LINC02223 Silent rs10079374 5 17828138 [A/G] NR_134286 LINC02223 Silent rs1355701 5 17830266 [A/G] NR_134286 LINC02223 Silent rs6896120 5 17836897 [T/C] NR_134286 LINC02223 Silent rs4866172 5 17849527 [A/C] NR_134286 LINC02223 Silent rs1513081 5 17861315 [T/C] NR_134286 LINC02223 Silent rs6863135 5 17862984 [A/C] NR_134286 LINC02223 Silent rs9632412 5 17871184 [A/G] NR_134286 LINC02223 Silent rs12659663 5 17877417 [T/C] NR_134286 LINC02223 Silent rs1542128 5 17891126 [T/C] NR_134286 LINC02223 Silent rs17710915 5 17893556 [T/C] NR_134286 LINC02223 Silent rs7726178 5 17896146 [A/G] NR_134286 LINC02223 Silent rs6863677 5 17899205 [A/G] NR_134286 LINC02223 Silent rs12655829 5 17902917 [T/C] NR_134286 LINC02223 Silent rs16887451 5 17918575 [A/C] NR_134286 LINC02223 Silent rs12514079 5 17920818 [A/G] NR_134286 LINC02223 Silent rs1443402 5 17922072 [T/C] NR_134286 LINC02223 Silent rs1513089 5 17929608 [T/G] NR_134286 LINC02223 EXON Silent rs6869207 5 17930264 [T/G] NR_134286 LINC02223 EXON Silent rs13190514 5 17933120 [T/C] rs4866258 5 17933360 [T/C] rs782847 5 17953026 [A/C] rs1033148 5 17956340 [A/G] rs1813454 5 17961096 [A/G] rs10941929 5 17981553 [A/C] rs10520854 5 17989256 [A/G] rs6869139 5 17996519 [A/G] rs2662605 5 17999554 [A/G] rs692332 5 18000871 [T/C] rs505682 5 18007227 [A/G] rs691027 5 18009498 [A/G] rs7733771 5 18010430 [T/G] rs704029 5 18011605 [A/C] rs1976571 5 18017619 [A/G] rs17839277 5 18022107 [A/G] rs10061385 5 18030481 [A/G] rs1390630 5 18035736 [A/G] rs1698038 5 18038790 [T/C] rs13186768 5 18048683 [T/C] rs10941964 5 18050107 [T/C] rs7714990 5 18051124 [T/G] rs2455406 5 18051144 [T/G] rs17839273 5 18051941 [T/C] rs691970 5 18052634 [A/G] rs17711516 5 18058107 [A/G] rs645642 5 18066721 [T/C] rs618959 5 18068103 [T/G] rs691360 5 18074375 [T/C] rs606186 5 18078815 [A/G] rs6452084 5 18081055 [A/G] rs2561637 5 18081343 [T/C] rs609071 5 18092224 [A/G] rs10052761 5 18095876 [A/G] rs2561642 5 18099766 [T/C] rs9687895 5 18116055 [A/G] rs2198174 5 18122894 [T/C] rs6452106 5 18126244 [A/G] rs437171 5 18129805 [A/G] rs11747108 5 18134747 [T/G] rs2443546 5 18142966 [A/G] rs17547230 5 18143541 [A/G] rs10057043 5 18146907 [T/C] rs13357690 5 18151435 [A/G] rs7727170 5 18154453 [T/C] rs583360 5 18156319 [T/C] rs7713131 5 18157577 [A/G] rs7731064 5 18167748 [T/C] rs10037793 5 18168945 [A/G] rs1504192 5 18173795 [T/C] rs442958 5 18176583 [A/G] rs6866168 5 18180017 [T/C] rs4866305 5 18194227 [A/G] rs3849678 5 18203619 [T/G] rs6895865 5 18210827 [T/G] rs2938416 5 18212238 [T/C] rs17712246 5 18215198 [T/C] rs17661265 5 18215931 [T/C] rs2938442 5 18242558 [T/C] rs1587796 5 18247297 [A/G] rs2938462 5 18263045 [A/G] rs1543947 5 18264463 [T/C] rs13179760 5 18267949 [T/G] rs6868510 5 18268789 [T/C] rs1354424 5 18272737 [T/C] rs1857707 5 18277597 [A/C] rs4866315 5 18279260 [T/C] rs1032714 5 18281760 [A/G] rs314020 5 18284077 [A/C] rs2962908 5 18284394 [A/C] rs2938443 5 18288995 [T/C] rs17630210 5 18293483 [T/C] rs986680 5 18294160 [T/C] rs314029 5 18300739 [A/G] rs453836 5 18303726 [A/G] rs375593 5 18304552 [T/C] rs314023 5 18319276 [T/G] rs2938469 5 18324937 [T/C] rs6868560 5 18327110 [A/G] rs4490579 5 18327313 [A/C] rs314025 5 18327605 [T/C] rs1500206 5 18330038 [A/G] rs2036328 5 18335042 [T/C] rs1405707 5 18338272 [A/G] rs2650445 5 18351036 [T/G] rs6895355 5 18356268 [T/C] rs11948468 5 18356447 [A/G] rs6879881 5 18356582 [A/G] rs2950483 5 18362647 [A/C] rs2204613 5 18368594 [T/C] rs11953945 5 18374315 [T/C] rs10942142 5 18379534 [A/G] rs7720380 5 18386675 [T/C] rs13360190 5 18391369 [A/G] rs2962933 5 18393343 [T/G] rs1918342 5 18393514 [A/C] rs6452273 5 18393812 [A/G] rs10461822 5 18394610 [A/G] rs4866100 5 18396384 [A/C] rs6898878 5 18412476 [A/G] rs17729677 5 18414685 [A/G] rs13155604 5 18416476 [A/G] rs2962896 5 18418083 [A/G] rs2962954 5 18423194 [A/G] rs2962949 5 18424199 [T/G] rs10065090 5 18433482 [A/G] rs1405705 5 18435446 [A/G] rs1358319 5 18439405 [T/C] rs12657680 5 18453812 [T/C] rs17662227 5 18455136 [A/G] rs4866333 5 18461047 [T/G] rs9918121 5 18464854 [T/C] rs17630875 5 18466302 [T/G] rs10063237 5 18467699 [A/G] rs6452351 5 18481984 [T/C] rs10042810 5 18482995 [T/C] rs4866334 5 18483651 [T/C] rs4866335 5 18484034 [A/G] rs4302587 5 18484728 [T/G] rs1980373 5 18490517 [A/C] rs1527383 5 18492554 [A/G] rs11750643 5 18492839 [A/C] rs10520858 5 18495544 [T/C] rs1405708 5 18495883 [T/G] rs4334889 5 18496264 [A/G] rs4348220 5 18500953 [A/G] rs10051365 5 18501530 [A/G] rs11954903 5 18503663 [T/C] rs7701896 5 18513822 [A/G] rs9688294 5 18520930 [A/G] rs9688315 5 18521319 [A/C] rs6876174 5 18529071 [A/G] rs13188100 5 18532785 [T/C] rs11749277 5 18544459 [A/G] rs9687246 5 18548150 [A/G] rs7724567 5 18561967 [T/C] rs6891237 5 18564331 [A/G] rs4334892 5 18565153 [A/G] rs4866340 5 18572605 [T/G] rs981275 5 18573774 [T/C] rs12654064 5 18578054 [T/C] rs6863200 5 18578445 [A/G] rs12658762 5 18579606 [T/G] rs11954300 5 18581119 [A/C] rs1908699 5 18586907 [A/G] rs1826812 5 18599038 [T/C] rs12153172 5 18601469 [A/G] rs1845831 5 18607036 [T/G] rs4866111 5 18615384 [T/C] rs1390566 5 18624481 [T/C] rs1845830 5 18629409 [A/G] rs7716489 5 18637320 [T/C] rs10214230 5 18640685 [T/G] rs4529196 5 18655253 [A/C] rs10076033 5 18658693 [A/G] rs13167620 5 18662625 [T/C] rs7710886 5 18678904 [T/G] rs961606 5 18684530 [T/C] rs10057740 5 18685677 [A/G] rs959738 5 18688976 [T/C] rs329904 5 18689116 [T/G] rs13176281 5 18691618 [T/C] rs13162697 5 18692207 [A/G] rs16886725 5 18692338 [A/C] rs10940770 5 18693810 [A/C] rs393268 5 18694475 [A/G] rs329891 5 18698028 [A/G] rs172953 5 18715166 [T/G] rs10064581 5 18726660 [T/C] rs2102146 5 18727016 [A/G] rs1846989 5 18728610 [A/C] rs12516484 5 18729080 [T/C] rs10472159 5 18732060 [A/G] rs16886683 5 18733182 [T/G] rs16886679 5 18738297 [A/G] rs2937515 5 18741673 [A/G] rs4482907 5 18759551 [A/G] rs2962228 5 18773727 [A/G] rs7713991 5 18777638 [T/C] rs17631488 5 18777746 [A/G] rs2962233 5 18783485 [A/G] rs16886656 5 18789777 [T/C] rs1393137 5 18789976 [T/C] rs12515138 5 18792568 [T/C] rs11741301 5 18794692 [A/G] rs1021771 5 18795292 [A/C] rs10040259 5 18797589 [A/G] rs12518042 5 18799045 [T/G] rs13172937 5 18803801 [T/C] rs6450728 5 18809420 [A/G] rs17663114 5 18809531 [T/C] rs10036680 5 18814214 [T/G] rs7715365 5 18816719 [A/C] rs10472175 5 18819946 [A/G] rs10062771 5 18823641 [A/G] rs4866126 5 18833633 [A/G] rs905177 5 18833784 [T/C] rs10057220 5 18838134 [T/C] rs9292384 5 18839672 [T/C] rs11747895 5 18852401 [A/G] rs11948748 5 18853732 [T/G] rs9918266 5 18854429 [A/G] rs13169561 5 18863659 [T/C] rs13165779 5 18863799 [A/G] rs17269457 5 18863867 [A/G] rs2201624 5 18866362 [A/G] rs6450785 5 18867568 [T/C] rs6878434 5 18868357 [T/C] rs10065818 5 18877165 [T/C] rs10059239 5 18879807 [A/C] rs6893620 5 18881698 [A/G] rs16886530 5 18882863 [T/C] rs10055996 5 18885119 [A/G] rs16886522 5 18885615 [A/C] rs10472760 5 18890253 [T/G] rs2201628 5 18892930 [T/G] rs1566038 5 18895407 [T/C] rs11957143 5 18908745 [T/G] rs11958034 5 18909675 [A/G] rs12652071 5 18913137 [T/G] rs4521476 5 18917828 [A/G] rs11951878 5 18921988 [T/G] rs4379197 5 18929720 [A/G] rs4394123 5 18936590 [T/C] rs11955931 5 18940647 [A/G] rs3935803 5 18944261 [A/G] rs10940958 5 18950552 [A/G] rs4309976 5 18954716 [T/C] rs6450841 5 18958747 [T/C] rs13176582 5 18962571 [T/C] rs10040022 5 18964842 [A/G] rs4597970 5 18971937 [T/C] rs12110283 5 18977475 [T/G] rs10940978 5 18982961 [T/C] rs10035187 5 18985998 [A/G] rs4263496 5 18994108 [T/G] rs4866134 5 18999510 [T/C] rs12515368 5 18999592 [A/G] rs7443398 5 19001160 [A/G] rs4286672 5 19002291 [T/C] rs10036524 5 19023177 [A/G] rs4515302 5 19027541 [A/C] rs6450894 5 19031835 [A/G] rs10941008 5 19041768 [T/C] rs4130533 5 19059786 [T/C] rs7723526 5 19066292 [A/G] rs13163797 5 19067546 [T/C] rs13181998 5 19068967 [A/G] rs4421107 5 19077737 [A/C] rs12054808 5 19085981 [A/G] rs7714384 5 19086655 [T/C] rs4391167 5 19087783 [A/G] rs4327600 5 19093749 [T/C] rs6450929 5 19096772 [A/G] rs4461634 5 19103049 [A/G] rs11950518 5 19121428 [A/G] rs10805579 5 19127527 [A/G] rs4479845 5 19138854 [A/G] rs11950664 5 19148922 [T/C] rs11740707 5 19148952 [T/C] rs4640795 5 19151180 [T/C] rs7720434 5 19152050 [A/G] rs7709474 5 19155786 [T/G] rs4552600 5 19156521 [A/G] rs10941077 5 19158050 [T/C] rs9637779 5 19160015 [A/G] rs9637789 5 19160113 [A/G] rs12518778 5 19171872 [A/G] rs13153741 5 19183884 [T/C] rs4492113 5 19185179 [A/C] rs4505952 5 19188359 [A/G] rs4318784 5 19189948 [T/C] rs10059141 5 19195667 [T/C] rs10061156 5 19196465 [T/G] rs10061411 5 19199387 [A/G] rs4397134 5 19199789 [T/C] rs10056848 5 19200634 [A/G] rs11948213 5 19201028 [A/C] rs4403177 5 19208299 [A/C] rs4293920 5 19223080 [T/C] rs4291014 5 19235686 [A/G] rs6868154 5 19240987 [A/G] rs10941199 5 19247098 [T/C] rs4490578 5 19266101 [A/G] rs6888100 5 19271333 [T/C] rs4535457 5 19280885 [T/C] rs4524512 5 19285249 [T/C] rs4552597 5 19291890 [A/G] rs4543268 5 19295220 [A/G] rs2967017 5 19328003 [T/G] rs10058333 5 19331778 [A/G] rs2967023 5 19335496 [A/G] rs16886133 5 19341264 [A/G] rs16886123 5 19344220 [A/G] rs1512551 5 19346137 [T/C] rs2942295 5 19358684 [A/G] rs12652028 5 19362998 [A/C] rs877314 5 19364608 [A/C] rs2942291 5 19367728 [A/G] rs925511 5 19376830 [T/G] rs7717664 5 19385395 [T/C] rs1877462 5 19389256 [A/G] rs17279060 5 19392363 [T/C] rs12189480 5 19392440 [A/G] rs1040005 5 19393347 [A/G] rs2942329 5 19393903 [T/C] rs12189093 5 19394510 [T/C] rs1858432 5 19398317 [T/G] rs1512548 5 19399602 [T/C] rs17279632 5 19400324 [T/C] rs2966994 5 19400350 [A/C] rs10520859 5 19412775 [T/C] rs2942302 5 19421313 [A/G] rs10039593 5 19425092 [A/G] rs1021470 5 19427619 [A/G] rs770140 5 19430825 [A/G] rs349475 5 19440168 [T/C] rs10520861 5 19441735 [T/C] rs623213 5 19446308 [A/C] rs17280924 5 19448847 [T/C] rs1707015 5 19448955 [T/C] rs17281015 5 19450474 [A/G] rs346784 5 19451589 [A/G] rs349468 5 19459826 [T/G] rs349474 5 19462474 [T/C] rs12521214 5 19462972 [T/C] rs1707025 5 19463410 [T/C] rs17215554 5 19463574 [T/C] rs347703 5 19467722 [A/C] rs347706 5 19469443 [T/C] rs770297 5 19472907 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12517061 5 19473029 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3792727 5 19484182 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13170473 5 19488982 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6894128 5 19490899 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11951215 5 19493537 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1486849 5 19493684 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs392488 5 19498390 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1684848 5 19502141 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16885897 5 19504176 [A/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs347720 5 19513668 [T/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1126069 5 19518321 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1000727 5 19520236 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1000726 5 19520405 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs441865 5 19520932 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs3828573 5 19527753 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs770298 5 19531296 [A/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7734519 5 19531541 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs995491 5 19534805 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs770301 5 19537726 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10941339 5 19543155 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs347740 5 19547577 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs347736 5 19548157 [A/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16885811 5 19548361 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10472287 5 19548843 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1631077 5 19551292 [T/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6882679 5 19555266 [A/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10041390 5 19573680 [A/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1565004 5 19574173 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16885756 5 19575900 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7704186 5 19578538 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9292679 5 19583251 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6877651 5 19585940 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13167417 5 19588949 [A/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2972819 5 19597038 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1352199 5 19610285 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs164448 5 19611680 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7730733 5 19613520 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4866038 5 19619844 [A/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2078188 5 19647970 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4866148 5 19655277 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11745155 5 19661628 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1521023 5 19668948 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4866039 5 19678764 [T/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6887118 5 19679108 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1521025 5 19736950 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1521026 5 19737003 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17839317 5 19742733 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6894851 5 19744872 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12109816 5 19751140 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7705221 5 19772620 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6896368 5 19780826 [A/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10068995 5 19800575 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4392624 5 19804889 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10078346 5 19826902 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6451476 5 19827322 [T/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10076681 5 19839695 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6883590 5 19844298 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6866603 5 19844853 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10074201 5 19848872 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6888443 5 19861546 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1911861 5 19865904 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17222830 5 19868580 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16888157 5 19871092 [A/G] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1876603 5 19872234 [A/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6869352 5 19880618 [T/C] NM_001349562,NM_001291957,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4866159 5 19892934 [T/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12658322 5 19902953 [T/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10051031 5 19906917 [A/G] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1911856 5 19919301 [T/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7720092 5 19920338 [T/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7734813 5 19920554 [T/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12655266 5 19923791 [A/G] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2202798 5 19926525 [T/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1911845 5 19929288 [T/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9986203 5 19932686 [T/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13177416 5 19948930 [T/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6451573 5 19949403 [T/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2388044 5 19951337 [T/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13175060 5 19958804 [T/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2892429 5 19970119 [A/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10805661 5 19980882 [T/G] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1540751 5 19985234 [T/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7736515 5 19987468 [A/C] NM_001349562,NM_001349563,NM_004934,NM_001349556,NM_001349561,NM_001291956,NM_001167667,NM_001349558,NM_001349560,NM_001349559 CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13359142 5 20010784 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs7704008 5 20012392 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs3112489 5 20016599 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs4292450 5 20028798 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs6860771 5 20030472 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs2892442 5 20030652 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs11955587 5 20031683 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1435971 5 20032008 [T/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1347523 5 20053583 [A/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs9292857 5 20070133 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs6869124 5 20073777 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10434577 5 20075855 [A/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs13170493 5 20107527 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs11744487 5 20109561 [A/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs6878897 5 20114606 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10473307 5 20123406 [A/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1435972 5 20124530 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10060069 5 20143940 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1435977 5 20150939 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs9292895 5 20174836 [T/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs7706987 5 20176887 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs7730162 5 20178290 [T/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs925185 5 20194982 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs11738280 5 20207714 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10473344 5 20208626 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1508584 5 20216940 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs6887472 5 20225602 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs4866047 5 20235071 [A/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs7730653 5 20238774 [T/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10071248 5 20248382 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10473372 5 20261150 [A/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs2974591 5 20290034 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs12522283 5 20290727 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs11954482 5 20300593 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs11746410 5 20302678 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10070509 5 20312639 [A/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558,NR_146519 CDH18,CDH18,CDH18,CDH18,CDH18-AS1 Silent,Silent,Silent,Silent,Silent rs10079950 5 20322049 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558,NR_146519 CDH18,CDH18,CDH18,CDH18,CDH18-AS1 Silent,Silent,Silent,Silent,Silent rs4493674 5 20322204 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558,NR_146519 CDH18,CDH18,CDH18,CDH18,CDH18-AS1 Silent,Silent,Silent,Silent,Silent rs6884961 5 20325180 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558,NR_146519 CDH18,CDH18,CDH18,CDH18,CDH18-AS1 Silent,Silent,Silent,Silent,Silent rs10056461 5 20325196 [A/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558,NR_146519 CDH18,CDH18,CDH18,CDH18,CDH18-AS1 Silent,Silent,Silent,Silent,Silent rs6897700 5 20348425 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs6870586 5 20355032 [T/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10078676 5 20358169 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10473391 5 20364007 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10941700 5 20366035 [T/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs11741365 5 20366537 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs11748566 5 20367267 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs7734222 5 20369746 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs6865971 5 20370847 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10073450 5 20380859 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10941711 5 20382657 [A/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10066903 5 20401352 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs12514159 5 20419469 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs9687957 5 20420209 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10062513 5 20429345 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs13357704 5 20439891 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs6877123 5 20443700 [A/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs6887953 5 20446058 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs4866190 5 20446378 [A/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs9292940 5 20447801 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs13180247 5 20451383 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1508545 5 20452114 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs12659684 5 20453495 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1472892 5 20459638 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1508548 5 20462781 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10067934 5 20464464 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs12697585 5 20474634 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs981587 5 20491707 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs992958 5 20492277 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1355057 5 20502578 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs12520315 5 20518529 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs13190303 5 20519284 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs2471138 5 20520802 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs2457040 5 20524918 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs2202790 5 20528774 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs992390 5 20535191 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1703052 5 20538115 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1651443 5 20539266 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs10077843 5 20542032 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1703042 5 20548944 [T/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1703043 5 20550503 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs12517650 5 20553425 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1703049 5 20559438 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs17839229 5 20563135 [T/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs2434785 5 20564905 [A/C] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs2434781 5 20570592 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs986251 5 20570987 [T/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs1030479 5 20574412 [A/G] NM_001349562,NM_001349556,NM_001291956,NM_001349558 CDH18,CDH18,CDH18,CDH18 Silent,Silent,Silent,Silent rs4401574 5 20579262 [T/G] rs2115342 5 20591074 [T/C] rs13164018 5 20591101 [T/C] rs13360869 5 20599667 [A/G] rs1007844 5 20606559 [A/G] rs2010326 5 20606656 [A/G] rs919344 5 20608142 [A/G] rs7713439 5 20608881 [T/C] rs2434772 5 20616080 [T/C] NR_149120 LINC02241 Silent rs919345 5 20621653 [A/G] NR_149120 LINC02241 Silent rs10040449 5 20623637 [T/C] NR_149120 LINC02241 Silent rs4866058 5 20626297 [A/C] NR_149120 LINC02241 Silent rs4866203 5 20626322 [T/G] NR_149120 LINC02241 Silent rs11958512 5 20633323 [T/C] NR_149120 LINC02241 Silent rs11738154 5 20635932 [A/C] NR_149120 LINC02241 Silent rs7732005 5 20636493 [A/G] NR_149120 LINC02241 Silent rs6864883 5 20647735 [T/C] NR_149120 LINC02241 Silent rs9292952 5 20662047 [A/C] NR_149120 LINC02241 Silent rs13157298 5 20669942 [A/G] NR_149120 LINC02241 Silent rs6890147 5 20685297 [A/G] NR_149120 LINC02241 Silent rs7447602 5 20687905 [A/C] NR_149120 LINC02241 Silent rs10214361 5 20698464 [A/G] NR_149120 LINC02241 Silent rs10941853 5 20740586 [A/G] NR_149120 LINC02241 Silent rs28470417 5 20753945 [A/G] NR_149120 LINC02241 Silent rs10941855 5 20786582 [T/C] NR_149120 LINC02241 Silent rs7446081 5 20799399 [A/G] NR_149120 LINC02241 Silent rs10065829 5 20824694 [T/C] NR_149120 LINC02241 Silent rs4866066 5 20832133 [T/C] NR_149120 LINC02241 Silent rs7443061 5 20835592 [A/G] NR_149120 LINC02241 Silent rs7719524 5 20859641 [A/G] NR_149120 LINC02241 Silent rs7442892 5 20865083 [A/G] NR_149120 LINC02241 Silent rs13436152 5 20873566 [A/G] NR_149120 LINC02241 Silent rs10079831 5 20878263 [A/G] NR_149120 LINC02241 Silent rs17634564 5 20886878 [A/G] NR_149120 LINC02241 Silent rs6886032 5 20892281 [A/G] NR_149120 LINC02241 Silent rs6867897 5 20894591 [A/G] NR_149120 LINC02241 Silent rs11956899 5 20902807 [T/C] NR_149120 LINC02241 Silent rs2201407 5 20924403 [T/C] NR_149120 LINC02241 Silent rs3913348 5 20947356 [A/C] rs1979833 5 20953429 [A/C] rs17238567 5 20964216 [A/G] rs12659921 5 20967185 [T/C] rs12657343 5 20967318 [A/C] rs1499730 5 20970069 [T/G] rs10037073 5 20975229 [T/C] rs13154017 5 20978211 [T/C] rs6878853 5 20981688 [T/C] rs10039669 5 20981800 [A/G] rs4613760 5 20982268 [T/C] rs10473457 5 20991326 [A/G] rs10473458 5 20991405 [T/G] rs9647542 5 20992734 [A/C] rs2221143 5 20995098 [A/G] rs4476767 5 21014949 [A/G] rs7717121 5 21016793 [T/G] rs13356534 5 21018813 [A/G] rs2088664 5 21018827 [A/G] rs10055596 5 21041496 [A/G] rs1027544 5 21047987 [T/G] rs366895 5 21067996 [A/G] rs9885417 5 21069363 [A/G] rs13436839 5 21071305 [T/C] rs364315 5 21073512 [T/C] rs832520 5 21075672 [T/C] rs13355668 5 21081373 [T/C] rs10058965 5 21082707 [T/C] rs17252666 5 21085280 [T/C] rs6873454 5 21092826 [T/C] rs16888939 5 21094862 [T/C] rs7446348 5 21117980 [A/G] rs6893407 5 21120491 [A/G] rs173559 5 21129114 [A/G] rs9292967 5 21137000 [T/C] rs248189 5 21143240 [A/G] rs432786 5 21148212 [A/G] rs294143 5 21153825 [T/C] rs16888991 5 21168358 [T/C] rs1388579 5 21170524 [T/C] rs159211 5 21185317 [T/G] rs2353442 5 21192757 [T/C] rs294114 5 21194251 [A/G] rs1388581 5 21198362 [A/G] rs294740 5 21200925 [A/C] rs16889078 5 21213478 [A/G] rs294713 5 21217860 [A/G] rs6451935 5 21234972 [T/C] rs1873609 5 21235554 [T/C] rs1388574 5 21238932 [T/C] rs6884724 5 21242810 [T/C] rs1038843 5 21257067 [T/C] rs6862720 5 21261450 [T/C] rs4866272 5 21265377 [A/G] rs7731475 5 21267757 [T/G] rs2883171 5 21273843 [T/G] rs10941887 5 21319693 [T/C] rs10055072 5 21391244 [T/C] rs10039330 5 21394707 [T/C] rs13173717 5 21396544 [A/G] rs10941894 5 21421187 [A/G] rs11746426 5 21421537 [A/G] rs11746478 5 21421712 [A/G] rs10043532 5 21428130 [A/G] rs10059041 5 21428775 [T/C] rs4645308 5 21432444 [T/C] rs6451953 5 21437412 [A/C] rs9292982 5 21504581 [A/C] NR_027026 GUSBP1 Silent rs6868224 5 21547156 [A/G] NR_027026 GUSBP1 Silent rs1817950 5 21551543 [T/C] NR_027026 GUSBP1 Silent rs1496455 5 21565058 [A/C] NR_027026 GUSBP1 Silent rs7720174 5 21574347 [A/G] NR_027026 GUSBP1 Silent rs12519981 5 21574610 [A/G] NR_027026 GUSBP1 Silent rs7725903 5 21575563 [A/G] NR_027026 GUSBP1 Silent rs515853 5 21585236 [A/C] NR_027026 GUSBP1 Silent rs2123096 5 21585420 [A/G] NR_027026 GUSBP1 Silent rs16888770 5 21586180 [A/G] NR_027026 GUSBP1 EXON Silent rs17683709 5 21586809 [T/C] NR_027026 GUSBP1 EXON Silent rs13163379 5 21588112 [A/G] NR_027026 GUSBP1 EXON Silent rs6896002 5 21588931 [A/C] NR_027026 GUSBP1 EXON Silent rs16888766 5 21589313 [T/C] NR_027026 GUSBP1 EXON Silent rs635597 5 21593623 [T/C] rs4701222 5 21600623 [T/C] rs583449 5 21603429 [A/G] rs1823674 5 21606517 [T/C] rs11745859 5 21607097 [A/G] rs7727211 5 21613878 [A/C] rs11956543 5 21622035 [T/C] rs6865279 5 21633249 [T/C] rs16888711 5 21634979 [T/G] rs13161353 5 21637415 [A/G] rs16888684 5 21640820 [T/C] rs7707385 5 21642121 [A/G] rs10075850 5 21656148 [A/G] rs533834 5 21660097 [A/G] rs663970 5 21665641 [T/C] rs516235 5 21674640 [T/C] rs586654 5 21676669 [T/C] rs693891 5 21680478 [A/G] rs2081963 5 21685482 [T/C] rs608141 5 21687377 [T/C] rs1390663 5 21689837 [T/G] rs1428670 5 21692989 [T/C] rs17259353 5 21699126 [T/C] rs13354466 5 21699135 [T/G] rs2443768 5 21701837 [A/C] rs2967900 5 21704695 [A/G] rs16888572 5 21718946 [A/G] rs6877795 5 21723745 [T/C] rs13189619 5 21727492 [A/G] rs7703394 5 21733331 [A/G] rs4701455 5 21742462 [A/C] rs13162954 5 21743174 [A/C] rs12108917 5 21747442 [A/G] rs12109285 5 21749348 [T/C] rs12109539 5 21751633 [T/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 EXON Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6451993 5 21752056 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 EXON Synonymous_D725D,Synonymous_D725D,Synonymous_D725D,Synonymous_D725D,Synonymous_D725D,Synonymous_D725D,Synonymous_D685D,Synonymous_D501D,Synonymous_D725D rs16888475 5 21757799 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2303748 5 21760602 [A/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2303749 5 21760731 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 EXON Synonymous_Q523Q,Synonymous_Q523Q,Synonymous_Q523Q,Synonymous_Q523Q,Synonymous_Q523Q,Synonymous_Q523Q,Synonymous_Q483Q,Synonymous_Q299Q,Synonymous_Q523Q rs12108814 5 21765178 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 EXON Missense_I475T,Missense_I475T,Missense_I475T,Missense_I475T,Missense_I475T,Missense_I475T,Missense_I435T,Missense_I251T,Missense_I475T rs13172717 5 21772052 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs1593985 5 21782214 [A/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10073204 5 21785328 [A/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16888389 5 21789926 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10078408 5 21792515 [T/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10055385 5 21798830 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11949505 5 21800192 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10063754 5 21802532 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4485890 5 21805266 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13359507 5 21810739 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs11952632 5 21813303 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6884278 5 21813967 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs17328673 5 21817206 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 EXON Missense_I284V,Missense_I284V,Missense_I284V,Missense_I284V,Missense_I284V,Missense_I284V,Missense_I244V,Missense_I60V,Missense_I284V rs13178987 5 21825829 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6887681 5 21826642 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4642327 5 21827593 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10059819 5 21838360 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10052427 5 21838995 [A/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9292995 5 21844034 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6452006 5 21847419 [T/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12171538 5 21847531 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7707626 5 21848085 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10060698 5 21853462 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9292996 5 21857517 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7379407 5 21857936 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6452011 5 21863318 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7446282 5 21871861 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10045440 5 21872292 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12153057 5 21872896 [T/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs9292998 5 21881016 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6874484 5 21881361 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6874819 5 21881514 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001364109,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4077772 5 21890139 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7713611 5 21893148 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7442799 5 21896184 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7442801 5 21896197 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6862581 5 21899432 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6452027 5 21901716 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16888815 5 21906026 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7379403 5 21906641 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6452029 5 21907093 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16888797 5 21909369 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10472473 5 21915317 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13162273 5 21917519 [A/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6452031 5 21918864 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7730479 5 21919536 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs16899347 5 21921582 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6452035 5 21925080 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs995740 5 21954665 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6892378 5 21995471 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10056037 5 21999692 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13167322 5 22006171 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4327574 5 22009253 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6897914 5 22016945 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4419561 5 22021896 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4337821 5 22024387 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6897994 5 22033716 [T/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10060822 5 22039679 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4540148 5 22040806 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10052686 5 22050002 [A/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6452045 5 22054565 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4301199 5 22062988 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7444702 5 22067437 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4554172 5 22068707 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4388179 5 22076455 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4371716 5 22078584 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 EXON Missense_V68M,Missense_V68M,Missense_V68M,Missense_V68M,Missense_V68M,Missense_V68M,Missense_V68M,Missense_V68M rs10055079 5 22081601 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs12519679 5 22083473 [T/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7710738 5 22101322 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs13186048 5 22106756 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6452051 5 22109314 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs10941934 5 22119976 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs2963652 5 22141555 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs7717005 5 22156155 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6866826 5 22189777 [A/G] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs6883351 5 22193967 [T/C] NM_001364107,NM_001364104,NM_001364108,NM_004061,NM_001364105,NM_001364106,NM_001317228,NM_001317227 CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent,Silent,Silent,Silent,Silent rs4518351 5 22219503 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs4560515 5 22219836 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs12189051 5 22222461 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs4458548 5 22222556 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs4437341 5 22225912 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs6865522 5 22227895 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10214205 5 22230090 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10473582 5 22233716 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs4385176 5 22243707 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs4593232 5 22243986 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs7446451 5 22244114 [T/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs6871980 5 22250652 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10473586 5 22272860 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs4701577 5 22273415 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs6452075 5 22273714 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs961678 5 22297726 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1373374 5 22298771 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs2068452 5 22300262 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1444120 5 22314300 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs2968384 5 22317026 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs13156363 5 22318776 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs7380241 5 22321952 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs13179082 5 22327274 [T/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs6863029 5 22328155 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs7710321 5 22329782 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs16894341 5 22344250 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs17265218 5 22351139 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs2883717 5 22355323 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1444128 5 22370872 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10473592 5 22375786 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1261368 5 22383949 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs13359749 5 22391075 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1261397 5 22397625 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs959266 5 22398914 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1261394 5 22400225 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs3112473 5 22402776 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1911960 5 22403473 [A/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs2355597 5 22403944 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1155443 5 22405345 [A/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs894911 5 22431467 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1911963 5 22445794 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs995178 5 22446214 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs995179 5 22446353 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs2010548 5 22458871 [T/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs2551514 5 22472039 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10039824 5 22474350 [T/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10473594 5 22476100 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1911956 5 22483586 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs440188 5 22492196 [A/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1393114 5 22494033 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs16896252 5 22494188 [T/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10040210 5 22507308 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs4320220 5 22516890 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1948748 5 22522625 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10036620 5 22527778 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10053834 5 22532710 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10052996 5 22536778 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs28474955 5 22549703 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs2134177 5 22550328 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs400155 5 22551757 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs13357733 5 22557624 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs16896912 5 22565804 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs271090 5 22573330 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs269876 5 22591057 [A/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10941965 5 22591472 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs4336322 5 22597757 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs16897184 5 22600409 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs833344 5 22604172 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1074463 5 22635369 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs16897695 5 22652137 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs12521573 5 22655865 [A/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs268972 5 22656527 [A/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10053320 5 22657926 [T/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1487414 5 22658043 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10941967 5 22658820 [A/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs6888198 5 22659406 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs7708701 5 22660564 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1038591 5 22670144 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs9293030 5 22683956 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs269017 5 22694384 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs269019 5 22694679 [A/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs6860776 5 22699592 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs174873 5 22707203 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs269024 5 22709981 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs447881 5 22716346 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs17292235 5 22717837 [T/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs416802 5 22718422 [A/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs9293036 5 22730468 [T/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs12188885 5 22733475 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs12188887 5 22733519 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs12519845 5 22733747 [T/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs2129612 5 22740008 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs17358356 5 22740091 [A/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs6452095 5 22741835 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs7705310 5 22742635 [T/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1487416 5 22743760 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1867072 5 22748607 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs4701298 5 22751348 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs2119887 5 22755474 [A/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs17358685 5 22756398 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs958614 5 22759508 [A/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs16899078 5 22761272 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs11953049 5 22770519 [T/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs17359069 5 22776609 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs7715585 5 22777371 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs2584443 5 22780471 [A/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10053329 5 22783099 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10054624 5 22786428 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs780188 5 22790036 [T/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs16899478 5 22791335 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1707082 5 22793334 [T/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1561836 5 22794657 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs9293037 5 22799308 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs780179 5 22812264 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs13184821 5 22813022 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs16899832 5 22813520 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1442471 5 22817855 [A/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs12189454 5 22818921 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs10472487 5 22820390 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs9283772 5 22823694 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs11743201 5 22825527 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs1661975 5 22826121 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs16899375 5 22832585 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs11957688 5 22835892 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs780176 5 22842456 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs16900013 5 22843383 [A/G] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs12521133 5 22845094 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs13172440 5 22850914 [T/C] NM_001364104,NM_004061,NM_001364105,NM_001364106 CDH12,CDH12,CDH12,CDH12 Silent,Silent,Silent,Silent rs12652791 5 22856741 [T/C] rs4235521 5 22866518 [A/C] rs1707062 5 22869771 [T/C] rs4501305 5 22875782 [A/G] rs12658777 5 22882986 [A/C] rs1372667 5 22884601 [A/C] rs7727155 5 22892543 [A/G] rs13171806 5 22893819 [T/C] rs11956790 5 22902477 [T/G] rs10223085 5 22914565 [A/G] rs1820743 5 22923818 [T/C] rs1366421 5 22923887 [T/C] rs6881479 5 22941669 [T/G] rs11748547 5 22946602 [T/C] rs16901088 5 22949159 [A/G] rs11959007 5 22956970 [A/C] rs2635633 5 22987157 [A/G] rs1607561 5 22989071 [T/C] rs1607562 5 22989124 [A/G] rs2680768 5 22991089 [A/G] rs1896710 5 22991845 [T/C] rs10041756 5 22996240 [A/G] rs13154490 5 23000050 [T/C] rs9293045 5 23001166 [A/G] rs13185192 5 23002385 [A/G] rs2561710 5 23002989 [A/G] rs1879060 5 23004208 [A/G] rs16901708 5 23006054 [A/G] rs7717841 5 23008670 [A/C] rs10473612 5 23018272 [A/G] rs2635636 5 23019136 [A/C] rs2680798 5 23036721 [T/C] rs2635642 5 23038845 [A/G] rs1969336 5 23045219 [T/G] rs17299353 5 23048840 [A/G] rs10066309 5 23049365 [A/G] rs10069864 5 23050073 [T/G] rs6879343 5 23056410 [T/C] rs1980221 5 23056837 [A/G] rs4701339 5 23062359 [T/C] rs4701340 5 23062497 [A/G] rs9293051 5 23063296 [A/G] rs1401627 5 23065165 [A/G] rs16889985 5 23070854 [T/C] rs1836564 5 23072759 [T/C] rs10941977 5 23073936 [A/G] rs7709491 5 23077403 [A/G] rs12655902 5 23078005 [T/C] rs1519433 5 23085145 [A/G] rs10051791 5 23090994 [T/C] rs12515326 5 23092940 [T/C] rs12653590 5 23094809 [A/C] rs2078301 5 23100596 [T/C] rs10067560 5 23101848 [A/G] rs310906 5 23101921 [T/C] rs10520885 5 23103741 [A/G] rs310904 5 23104936 [T/G] rs10053648 5 23127912 [A/G] rs1435231 5 23132868 [A/C] rs1995264 5 23138951 [A/G] rs10038745 5 23139973 [T/C] rs10520887 5 23150924 [A/G] rs11958955 5 23153562 [T/C] rs7736091 5 23155672 [T/G] rs9293057 5 23156895 [T/C] rs178126 5 23157813 [T/G] rs17301584 5 23160613 [T/C] rs17301661 5 23160757 [A/G] rs2356520 5 23166756 [T/C] rs10054732 5 23168080 [T/C] rs1435230 5 23179275 [A/G] rs16892093 5 23210180 [A/G] rs10067536 5 23210213 [A/C] rs10050974 5 23213699 [T/G] rs10072467 5 23216237 [T/C] rs4701351 5 23221917 [T/C] rs13356042 5 23230718 [A/C] rs6892513 5 23237060 [T/C] rs7731943 5 23237298 [T/C] rs16892262 5 23239197 [A/G] rs975072 5 23239214 [A/G] rs6864495 5 23239589 [T/C] rs17375683 5 23241797 [T/C] rs919331 5 23242685 [T/C] rs919332 5 23243079 [A/G] rs7726338 5 23243400 [T/C] rs17376026 5 23244025 [T/C] rs7715927 5 23247790 [A/G] rs992276 5 23251380 [T/C] rs12519973 5 23251835 [A/G] rs12522270 5 23251869 [A/G] rs994675 5 23254969 [A/G] rs10074118 5 23258050 [T/C] rs1428615 5 23260501 [T/C] rs17376271 5 23261312 [A/G] rs1366450 5 23261792 [T/C] rs16892299 5 23261842 [A/G] rs10520889 5 23280920 [T/C] rs7727513 5 23281444 [A/G] rs17310973 5 23283435 [A/G] rs16892365 5 23289173 [T/C] rs1428624 5 23290393 [T/C] rs10941982 5 23298902 [A/C] rs16899394 5 23304881 [T/C] rs980924 5 23308068 [A/G] rs13171218 5 23312195 [T/C] rs6859490 5 23313059 [T/C] rs1896726 5 23315549 [T/C] rs17312807 5 23325432 [T/G] rs9293064 5 23327548 [T/C] rs7723652 5 23328403 [A/G] rs10051288 5 23331446 [A/C] rs3924616 5 23356973 [A/G] rs9686666 5 23362929 [A/G] rs10037553 5 23365538 [A/C] rs10058259 5 23371163 [A/G] rs10050856 5 23371640 [T/C] rs10069320 5 23385481 [A/C] rs6861038 5 23389253 [A/G] rs9293071 5 23403282 [T/C] rs13175283 5 23413553 [T/G] rs4073794 5 23415270 [T/C] rs13166680 5 23416474 [T/G] rs4467669 5 23422169 [A/G] rs10941984 5 23428613 [A/G] rs10076019 5 23428999 [T/C] rs16892462 5 23436727 [A/C] rs13359841 5 23439312 [A/G] rs2973628 5 23446583 [T/G] rs2914263 5 23452924 [A/G] rs2914261 5 23454500 [T/G] rs1991495 5 23454599 [T/C] rs4701373 5 23456194 [T/G] rs17379153 5 23456700 [T/C] rs890965 5 23457592 [A/G] rs10520891 5 23458289 [A/G] rs13354541 5 23468155 [T/G] rs1896701 5 23468792 [A/G] rs13159483 5 23475692 [T/C] rs11745765 5 23476402 [A/G] rs2934789 5 23484372 [T/C] rs2115259 5 23488636 [T/C] rs10075972 5 23493956 [T/C] rs12523581 5 23501599 [T/C] rs1994929 5 23507631 [T/C] rs16874445 5 23520907 [A/G] NM_020227,NM_001310214 PRDM9,PRDM9 Silent,Silent rs7715803 5 23521958 [A/G] NM_020227,NM_001310214 PRDM9,PRDM9 Silent,Silent rs1874165 5 23523348 [T/C] NM_020227,NM_001310214 PRDM9,PRDM9 Silent,Silent rs3805547 5 23528007 [A/G] NM_020227,NM_001310214 PRDM9,PRDM9 EXON Silent,Silent rs6889665 5 23532643 [T/C] rs12153202 5 23533746 [T/C] rs6896123 5 23536437 [A/G] rs13356803 5 23564714 [T/C] rs16892558 5 23571543 [T/C] rs6881387 5 23574209 [A/G] rs2973620 5 23578441 [A/G] rs16892593 5 23584544 [T/C] rs1494594 5 23584606 [T/C] rs1006153 5 23591455 [T/C] rs2029778 5 23593763 [T/G] rs16892616 5 23594090 [T/C] rs10043677 5 23596252 [T/C] rs10077618 5 23604239 [A/G] rs6868206 5 23605043 [A/G] rs6868212 5 23614535 [A/G] rs9293080 5 23616098 [A/G] rs12656827 5 23616278 [A/G] rs1521009 5 23621475 [A/G] rs2030419 5 23622036 [T/C] rs2030420 5 23622185 [A/G] rs1521011 5 23622492 [T/C] rs7718389 5 23623138 [A/G] rs7705488 5 23623207 [T/C] rs7705523 5 23623268 [T/C] rs7719907 5 23623397 [T/C] rs17316188 5 23623610 [A/G] rs1402410 5 23635910 [T/C] rs1464391 5 23654181 [T/G] rs10462244 5 23684585 [A/G] rs7713783 5 23685550 [T/C] rs6452136 5 23687013 [T/C] rs1814984 5 23687444 [A/C] rs7716265 5 23689295 [A/G] rs12516553 5 23694438 [T/C] rs11953664 5 23696111 [T/C] rs1521006 5 23697300 [A/G] rs6875157 5 23710644 [T/C] rs11743379 5 23716350 [T/C] rs1879480 5 23730041 [T/C] rs3932338 5 23742976 [A/G] rs4701393 5 23755699 [T/C] rs1520985 5 23758878 [A/G] rs10060443 5 23761700 [A/G] rs13174015 5 23778344 [A/G] rs4569836 5 23781623 [A/G] rs7705043 5 23820861 [T/C] rs10066234 5 23823932 [A/G] rs10942009 5 23858021 [T/C] rs6871540 5 23861064 [A/C] rs4701405 5 23872046 [A/G] rs7714862 5 23877218 [A/G] rs966297 5 23878207 [A/G] rs1490758 5 23884440 [T/C] rs12188875 5 23900238 [A/G] rs16892976 5 23907193 [A/C] rs2055526 5 23909410 [T/C] rs4479808 5 23919596 [T/C] rs7448471 5 23928233 [A/C] rs10473668 5 23960001 [A/G] NR_131245 C5orf17 Silent rs17428710 5 23961525 [T/C] NR_131245 C5orf17 Silent rs11950063 5 23980894 [A/G] NR_131245 C5orf17 EXON Silent rs6861036 5 24005118 [A/C] NR_131245 C5orf17 Silent rs1501949 5 24020558 [A/G] NR_131245 C5orf17 Silent rs1910071 5 24030812 [T/C] NR_131245 C5orf17 Silent rs17429271 5 24033839 [T/C] NR_131245 C5orf17 Silent rs6896352 5 24034550 [A/G] NR_131245 C5orf17 Silent rs6871776 5 24036642 [T/C] NR_131245 C5orf17 Silent rs11750284 5 24041489 [A/G] NR_131245 C5orf17 Silent rs17501504 5 24044704 [A/G] NR_131245 C5orf17 Silent rs17501608 5 24046739 [T/G] NR_131245 C5orf17 Silent rs9885102 5 24053972 [T/C] NR_131245 C5orf17 Silent rs1501938 5 24059579 [A/G] NR_131245 C5orf17 Silent rs17501795 5 24066236 [A/G] NR_131245 C5orf17 Silent rs16893073 5 24072617 [T/C] NR_131245 C5orf17 Silent rs10078293 5 24075658 [T/C] NR_131245 C5orf17 Silent rs2099055 5 24088733 [A/G] NR_131245 C5orf17 Silent rs13177217 5 24092063 [A/C] NR_131245 C5orf17 Silent rs11743115 5 24093347 [A/C] NR_131245 C5orf17 Silent rs10054058 5 24098496 [A/C] NR_131245 C5orf17 Silent rs17444026 5 24099822 [T/C] NR_131245 C5orf17 Silent rs10040797 5 24100181 [A/G] NR_131245 C5orf17 Silent rs10472510 5 24108374 [T/C] NR_131245 C5orf17 Silent rs11750295 5 24108770 [A/G] NR_131245 C5orf17 Silent rs11748076 5 24109062 [A/G] NR_131245 C5orf17 Silent rs13184473 5 24111077 [A/G] NR_131245 C5orf17 Silent rs11958182 5 24118301 [T/C] NR_131245 C5orf17 Silent rs10053948 5 24128474 [A/C] NR_131245 C5orf17 Silent rs10942028 5 24129266 [A/C] NR_131245 C5orf17 Silent rs11954471 5 24129417 [T/C] NR_131245 C5orf17 Silent rs16893146 5 24133971 [A/G] NR_131245 C5orf17 Silent rs1428199 5 24137390 [A/C] NR_131245 C5orf17 Silent rs1428201 5 24141118 [T/C] NR_131245 C5orf17 Silent rs6892387 5 24146519 [A/G] NR_131245 C5orf17 Silent rs7718527 5 24150299 [T/C] NR_131245 C5orf17 Silent rs2115122 5 24155061 [A/G] NR_131245 C5orf17 Silent rs17445670 5 24162206 [A/G] NR_131245 C5orf17 Silent rs6452189 5 24163109 [T/C] NR_131245 C5orf17 Silent rs9687325 5 24171380 [A/G] NR_131245 C5orf17 Silent rs1820694 5 24172136 [A/C] NR_131245 C5orf17 Silent rs9637784 5 24172252 [A/C] NR_131245 C5orf17 Silent rs6874374 5 24177944 [A/G] NR_131245 C5orf17 Silent rs1157943 5 24182088 [T/C] rs12108874 5 24184766 [A/G] rs7716833 5 24190097 [T/C] rs12654722 5 24198232 [A/C] rs4594816 5 24200574 [T/C] rs7723348 5 24206738 [T/C] rs10054081 5 24211218 [A/G] rs11748884 5 24219543 [T/C] rs10063082 5 24229197 [A/G] rs4554170 5 24230024 [T/C] rs6868533 5 24230888 [T/C] rs7721732 5 24235851 [A/C] rs4490548 5 24237693 [T/C] rs10040676 5 24239623 [T/C] rs10058162 5 24243009 [A/G] rs6867094 5 24243298 [T/C] rs11952208 5 24247673 [A/G] rs4277873 5 24259694 [T/G] rs10942035 5 24260655 [A/G] rs12518573 5 24261955 [A/G] rs5007912 5 24264090 [A/C] rs7700267 5 24269794 [A/G] rs2053183 5 24270683 [A/G] rs10805759 5 24274235 [A/G] rs10805760 5 24274495 [A/C] rs10214306 5 24279987 [T/G] rs1435820 5 24283625 [A/C] rs9654386 5 24287790 [A/C] rs10070171 5 24294511 [A/G] rs13360911 5 24296704 [A/G] rs6886864 5 24298575 [A/G] rs6452194 5 24301428 [A/G] rs10044803 5 24320108 [T/C] rs10037286 5 24320400 [T/G] rs934599 5 24320469 [T/C] rs1469832 5 24322935 [A/G] rs331250 5 24334452 [A/G] rs12519312 5 24335447 [A/C] rs4482869 5 24337141 [A/G] rs331303 5 24343572 [T/C] rs12519664 5 24351533 [A/C] rs972303 5 24355555 [T/C] rs331290 5 24357450 [A/G] rs28605677 5 24365309 [T/C] rs11949863 5 24382079 [A/G] rs2319567 5 24398596 [T/C] rs331214 5 24404807 [A/G] rs4701245 5 24430251 [A/G] rs331270 5 24438467 [A/G] rs10066192 5 24440340 [T/C] rs1978608 5 24441601 [T/C] rs2081922 5 24457943 [A/G] rs1346511 5 24463300 [A/G] rs1346509 5 24463538 [T/C] rs13188967 5 24469962 [T/C] rs9283777 5 24472315 [A/G] rs1428365 5 24482475 [T/C] rs2874027 5 24485005 [A/G] rs1169561 5 24486805 [T/C] rs6896096 5 24496862 [T/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs3815909 5 24498690 [T/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs7714385 5 24500645 [T/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs6889987 5 24503699 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs3797171 5 24509947 [A/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs4290982 5 24518074 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs13154399 5 24528612 [T/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs4701447 5 24528847 [T/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs6882202 5 24537481 [T/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs12652231 5 24541668 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs10473690 5 24541782 [T/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs10942055 5 24549616 [T/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs952168 5 24552177 [T/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs7735817 5 24552316 [T/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs10462251 5 24556172 [T/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs9293138 5 24558533 [T/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs17520214 5 24562793 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs12187078 5 24566690 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs13174538 5 24567660 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs17460736 5 24568262 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs11960361 5 24571058 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs12516067 5 24572261 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs10805767 5 24582271 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs7716158 5 24585329 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs2174529 5 24588189 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs11741076 5 24589871 [T/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs1505877 5 24592778 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs16893586 5 24593325 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs4701453 5 24597533 [A/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs16893608 5 24600075 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs16893610 5 24600638 [T/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs10054106 5 24607337 [T/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs11739680 5 24608169 [T/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs16893629 5 24608294 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs9293145 5 24609447 [A/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs16893647 5 24614132 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs17521324 5 24617958 [T/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs10067393 5 24620819 [A/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs10461813 5 24624103 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs1505890 5 24639574 [A/G] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs1395026 5 24643756 [T/C] NM_001317224,NM_001317222,NM_001362460,NM_006727 CDH10,CDH10,CDH10,CDH10 Silent,Silent,Silent,Silent rs332010 5 24645673 [A/G] rs332012 5 24646826 [T/C] rs2217383 5 24665518 [A/G] rs10037178 5 24666217 [A/G] rs2082058 5 24666440 [T/C] rs12152859 5 24679778 [A/G] rs2319236 5 24684928 [A/C] rs10070341 5 24691553 [T/C] rs7444707 5 24696993 [A/G] rs1896890 5 24703201 [A/G] rs13163171 5 24713205 [A/G] rs16893853 5 24722811 [T/C] rs1975076 5 24722992 [T/C] rs1975073 5 24723388 [T/G] rs10039614 5 24737095 [T/G] rs10044604 5 24738922 [T/C] rs10038996 5 24739100 [T/G] rs1963396 5 24740729 [T/C] rs7711384 5 24756604 [T/C] rs7700796 5 24770890 [T/C] rs10472517 5 24773509 [T/C] rs10462254 5 24775002 [A/G] rs1966590 5 24779565 [A/G] rs2059939 5 24781444 [A/G] rs16893943 5 24782611 [A/C] rs16893946 5 24782716 [T/C] rs10070741 5 24789752 [A/G] rs1835228 5 24791039 [A/C] rs1429570 5 24791380 [T/C] rs7737195 5 24794619 [T/C] rs1493245 5 24805795 [T/G] rs1169654 5 24806593 [T/C] rs1169653 5 24806889 [A/G] rs1183308 5 24809481 [A/G] rs1908045 5 24812268 [A/G] rs12522615 5 24817237 [A/G] rs16894002 5 24817630 [A/G] rs1960462 5 24822128 [T/G] rs16894006 5 24833120 [T/C] rs4421074 5 24833154 [T/C] rs6881214 5 24837899 [T/C] NR_037896 LINC02239 Silent rs6884872 5 24844413 [A/G] rs10071824 5 24846954 [T/C] rs13173735 5 24851080 [T/G] rs4701459 5 24851499 [T/C] rs1353066 5 24855099 [T/G] rs13162819 5 24856119 [T/C] rs10055390 5 24859690 [T/C] rs962088 5 24868417 [T/C] rs962087 5 24868444 [T/C] rs1353061 5 24871031 [A/G] rs17400935 5 24879885 [T/C] rs1389221 5 24884260 [T/C] rs4397097 5 24899257 [A/G] rs10042912 5 24902336 [T/C] rs1500198 5 24907439 [T/C] rs9283778 5 24913167 [T/G] rs7720640 5 24916565 [T/C] rs16894041 5 24917723 [T/G] rs904746 5 24919141 [A/G] rs7711040 5 24922595 [A/G] rs6452234 5 24922789 [A/G] rs2055073 5 24924797 [A/G] rs17401648 5 24926647 [A/G] rs9293159 5 24929660 [A/C] rs6452236 5 24930124 [A/G] rs10520903 5 24930711 [A/G] rs10805771 5 24934186 [T/C] rs12187422 5 24946851 [A/C] rs10039533 5 24947885 [T/C] rs11738003 5 24948884 [A/G] rs449802 5 24950392 [T/G] rs2201296 5 24967119 [A/G] rs2201295 5 24967172 [A/G] rs13174080 5 24976492 [T/C] rs1493478 5 25006350 [A/G] rs9784649 5 25011524 [A/G] rs6869061 5 25015565 [A/G] rs6866107 5 25027051 [A/G] rs17343615 5 25027618 [T/C] rs2873911 5 25030161 [T/C] rs9293161 5 25041490 [A/G] rs10053798 5 25050413 [A/G] rs11742222 5 25053641 [A/G] rs17403440 5 25054004 [T/C] rs16894132 5 25058616 [T/C] rs1160303 5 25060782 [T/C] rs9293162 5 25065470 [T/C] rs10520899 5 25067372 [T/C] rs6872919 5 25086440 [A/C] rs7733733 5 25089614 [T/C] rs7701392 5 25090716 [T/G] rs12521551 5 25095178 [A/G] rs4701466 5 25096593 [T/C] rs10942089 5 25097441 [T/C] rs11746102 5 25097916 [A/G] rs10065343 5 25120430 [T/C] rs11742952 5 25128890 [T/C] NR_147006 LINC02228 Silent rs10075166 5 25130313 [T/C] NR_147006 LINC02228 Silent rs12518815 5 25130699 [A/C] NR_147006 LINC02228 Silent rs6859537 5 25135494 [T/C] NR_147006 LINC02228 Silent rs13181240 5 25143399 [T/C] NR_147006 LINC02228 Silent rs4701473 5 25146653 [A/G] NR_147006 LINC02228 Silent rs414435 5 25164780 [T/C] NR_147006 LINC02228 Silent rs6890226 5 25180973 [A/G] NR_147006 LINC02228 Silent rs11955750 5 25184490 [A/G] NR_147006 LINC02228 Silent rs7732673 5 25190282 [A/G] NR_147006 LINC02228 Silent rs16894229 5 25194037 [A/G] NR_136209 LINC02211 Silent rs6871755 5 25195645 [T/C] NR_136209 LINC02211 Silent rs3913960 5 25228227 [T/C] NR_136209 LINC02211 Silent rs9293163 5 25239440 [T/G] NR_136209 LINC02211 Silent rs6860994 5 25248251 [T/C] NR_136209 LINC02211 Silent rs3913963 5 25254434 [A/G] NR_136209 LINC02211 Silent rs3843471 5 25278588 [A/G] NR_136209 LINC02211 Silent rs2063184 5 25302983 [A/G] rs13163964 5 25315404 [A/G] rs6890531 5 25329172 [A/G] rs7730066 5 25329322 [A/G] rs17523194 5 25333696 [T/G] rs1032987 5 25334013 [A/C] rs11738869 5 25340617 [A/C] rs4235532 5 25351609 [A/G] rs4701480 5 25355836 [T/C] rs12517406 5 25384728 [T/C] rs10462265 5 25386522 [T/C] rs10073102 5 25386907 [T/G] rs7349777 5 25390490 [T/C] rs10473744 5 25392632 [T/C] rs2332017 5 25393370 [A/G] rs7711948 5 25396006 [A/G] rs1169845 5 25400941 [T/C] rs10076119 5 25402825 [A/G] rs6872370 5 25403734 [A/G] rs4701483 5 25410448 [A/G] rs10062995 5 25412743 [A/G] rs2252299 5 25416205 [A/G] rs4092595 5 25417764 [A/C] rs2877553 5 25419907 [A/G] rs1904173 5 25420089 [A/G] rs12188009 5 25422667 [A/G] rs1904177 5 25431823 [A/G] rs12517129 5 25436319 [A/G] rs17524358 5 25437715 [T/G] rs6875620 5 25439384 [T/G] rs11740761 5 25446757 [A/C] rs17524924 5 25451344 [A/G] rs10036252 5 25451819 [A/G] rs2126965 5 25457358 [A/G] rs10520922 5 25463613 [T/G] rs12697661 5 25465482 [T/C] rs10473746 5 25468690 [T/C] rs13359266 5 25468811 [T/C] rs2126967 5 25470513 [A/G] rs10214406 5 25471283 [T/G] rs16894485 5 25471581 [A/G] rs1366277 5 25471838 [A/C] rs12186488 5 25471919 [A/G] rs2086142 5 25489061 [A/C] rs13164982 5 25490994 [T/C] rs10078091 5 25495005 [A/G] rs10058099 5 25504896 [A/G] rs9293168 5 25513207 [A/G] rs7705483 5 25515935 [A/G] rs10520921 5 25517376 [T/G] rs7720944 5 25518458 [T/C] rs7712799 5 25520961 [T/C] rs1428238 5 25523961 [T/C] rs4701486 5 25528242 [T/G] rs10052032 5 25532432 [A/G] rs4701487 5 25537415 [A/G] rs13181304 5 25538295 [A/G] rs12515108 5 25538947 [T/G] rs13154702 5 25540646 [A/G] rs13169085 5 25557717 [A/G] rs13166065 5 25558308 [A/G] rs6890172 5 25572097 [T/G] rs6876547 5 25572301 [T/G] rs1542563 5 25572996 [T/C] rs11953292 5 25573190 [T/C] rs11952604 5 25573209 [A/G] rs13158186 5 25576239 [A/G] rs2127392 5 25582936 [T/G] rs12515056 5 25594997 [A/G] rs10056747 5 25595051 [T/C] rs13159537 5 25608727 [T/C] rs36997 5 25611482 [A/G] rs16894618 5 25612336 [A/G] rs2331930 5 25615591 [A/G] rs2619780 5 25616251 [T/C] rs12520396 5 25618766 [A/G] rs10037787 5 25623001 [A/G] rs10942131 5 25632475 [A/C] rs11956371 5 25634038 [T/G] rs10462273 5 25636829 [T/C] rs13162889 5 25636848 [T/C] rs7733598 5 25643355 [T/C] rs7734006 5 25644220 [T/C] rs1479581 5 25646567 [T/C] rs12187966 5 25650030 [T/C] rs7723935 5 25650176 [A/G] rs10076963 5 25658882 [A/G] rs949661 5 25668834 [A/G] rs248755 5 25673651 [A/C] rs1479571 5 25676606 [A/C] rs9293175 5 25678072 [A/G] rs387456 5 25679253 [A/G] rs954478 5 25680392 [A/G] rs956628 5 25680417 [A/G] rs1479572 5 25686469 [T/C] rs10069367 5 25686495 [A/C] rs16894704 5 25687036 [T/G] rs187463 5 25687683 [T/G] rs173585 5 25688567 [T/G] rs10056274 5 25695377 [T/C] rs9688120 5 25695625 [T/C] rs1678761 5 25698030 [T/C] rs9293177 5 25699825 [A/G] rs10223141 5 25700070 [A/G] rs10520920 5 25700355 [A/C] rs2928179 5 25711728 [A/C] rs39595 5 25717110 [T/C] rs2972323 5 25717662 [T/C] rs255044 5 25720302 [A/G] rs10473762 5 25723615 [A/G] rs1842249 5 25737864 [A/G] rs168843 5 25739983 [A/G] rs1904458 5 25756561 [A/G] rs4435838 5 25757341 [A/G] rs2972297 5 25759320 [A/G] rs7727656 5 25760679 [T/G] rs12515469 5 25768871 [A/G] rs969400 5 25770271 [T/C] rs1479674 5 25774428 [A/G] rs7736846 5 25777784 [T/C] rs7718830 5 25781531 [A/G] rs12521681 5 25782399 [A/G] rs370277 5 25790587 [T/G] rs7703602 5 25808399 [A/C] rs384831 5 25811412 [A/G] rs366244 5 25817862 [A/G] rs2217326 5 25821685 [T/C] rs438523 5 25841323 [T/C] rs396045 5 25841613 [A/G] rs7447463 5 25847977 [A/G] rs13158538 5 25856000 [T/C] rs10805782 5 25856939 [T/C] rs1904460 5 25857050 [T/C] rs2195402 5 25868547 [T/C] rs12521157 5 25869401 [T/C] rs6878844 5 25874530 [A/C] rs13164425 5 25874921 [A/G] rs1366466 5 25875678 [A/C] rs6452297 5 25878699 [T/C] rs7443354 5 25881744 [T/C] rs10039219 5 25883408 [T/C] rs7704909 5 25898921 [T/C] rs1896731 5 25899020 [T/C] rs7705715 5 25899414 [T/C] rs16895091 5 25899711 [T/C] rs10038113 5 25902342 [T/C] rs6414928 5 25907909 [A/G] rs10942147 5 25910929 [A/G] rs12521388 5 25912113 [A/G] rs7727225 5 25913210 [A/G] rs12659830 5 25920401 [T/G] rs10050387 5 25928888 [T/C] rs12659150 5 25931434 [T/C] rs4516819 5 25933110 [A/G] rs12187724 5 25935070 [A/C] rs10063741 5 25944830 [T/C] rs4298222 5 25946454 [A/G] rs12515486 5 25951104 [T/C] rs10040577 5 25955765 [A/C] rs10942150 5 25962632 [A/G] rs6891206 5 25969379 [T/C] rs7732252 5 25970666 [A/G] rs4327572 5 25972821 [T/C] rs10038851 5 25974120 [A/C] rs11954820 5 25976052 [T/G] rs4314370 5 25976806 [A/G] rs4277876 5 25977806 [A/G] rs4537025 5 25991167 [T/C] rs4544798 5 25991253 [A/G] rs4594818 5 25992457 [A/G] rs7700465 5 26003284 [A/G] rs6888835 5 26008899 [T/C] rs4355485 5 26013301 [A/G] rs10067113 5 26016363 [T/C] rs4404644 5 26028389 [T/C] rs6452312 5 26030577 [A/G] rs1330656 5 26048462 [T/G] rs12514304 5 26057117 [T/G] rs10072518 5 26064803 [T/C] rs7707114 5 26072458 [T/C] rs1330642 5 26073238 [T/C] rs7714043 5 26088877 [T/C] rs12651738 5 26091605 [A/G] rs7716061 5 26099172 [T/C] rs9293221 5 26112192 [A/G] rs7721783 5 26114496 [A/G] rs11745199 5 26118309 [A/G] rs10039945 5 26120224 [T/C] rs1330660 5 26125639 [A/G] rs1330659 5 26125816 [A/G] rs4048817 5 26132948 [T/C] rs7710398 5 26135884 [T/G] rs7447064 5 26136566 [A/G] rs4081229 5 26147657 [T/G] rs1411589 5 26156304 [T/G] rs1541077 5 26157740 [A/G] rs12517600 5 26167566 [A/G] rs13173199 5 26172906 [T/C] rs10062689 5 26181001 [A/G] rs6883139 5 26182839 [T/C] rs6884362 5 26193999 [A/G] rs2094805 5 26196559 [A/G] rs1330676 5 26199587 [T/G] rs10942164 5 26201879 [A/G] rs4701531 5 26210563 [T/C] rs10942167 5 26219645 [A/G] rs12518513 5 26221764 [A/C] rs6865956 5 26223985 [A/C] rs6870351 5 26224041 [T/C] rs6884536 5 26224170 [A/G] rs6885388 5 26224692 [A/G] rs10035723 5 26230104 [T/C] rs13153758 5 26230491 [A/G] rs4701532 5 26231699 [A/G] rs4604153 5 26231934 [A/G] rs9293229 5 26238194 [T/C] rs6892024 5 26250248 [A/G] rs10068658 5 26263051 [T/C] rs10052385 5 26265398 [T/C] rs12153689 5 26266929 [T/C] rs12515630 5 26282637 [T/C] rs4273570 5 26283311 [A/G] rs4406110 5 26292815 [T/C] rs9293230 5 26293800 [A/G] rs10434626 5 26299629 [A/C] rs6862088 5 26322668 [A/G] rs2132018 5 26326179 [A/G] rs10040524 5 26334156 [A/G] rs6882967 5 26336760 [T/C] rs1389888 5 26344352 [T/G] rs6882953 5 26344613 [T/C] rs6866505 5 26349480 [A/G] rs12188862 5 26356507 [T/C] rs12652998 5 26364671 [A/G] rs4565182 5 26372563 [A/G] rs12654972 5 26378196 [A/G] rs12516042 5 26383317 [T/C] rs12519269 5 26383363 [T/C] rs7733495 5 26384007 [A/G] rs1154632 5 26394005 [A/G] rs16895575 5 26394185 [T/C] rs1494699 5 26394566 [T/C] rs4529155 5 26404614 [A/G] rs7706667 5 26406901 [A/G] rs6897774 5 26409352 [T/C] rs1587071 5 26410644 [T/C] rs7706669 5 26416388 [A/G] rs6866096 5 26416466 [T/G] rs11950170 5 26427064 [T/C] rs6885181 5 26428081 [A/G] rs13169349 5 26430825 [T/C] rs10942177 5 26431671 [T/C] rs6894058 5 26447676 [A/G] rs1494709 5 26456504 [A/G] rs6871724 5 26482424 [A/G] rs6877069 5 26509802 [A/G] rs1544945 5 26516629 [T/C] rs16895743 5 26523363 [T/C] rs1366492 5 26523488 [A/C] rs7702696 5 26528161 [A/G] rs1428718 5 26534253 [T/C] rs1025304 5 26537760 [T/C] rs4701544 5 26551516 [T/G] rs6867412 5 26555788 [A/G] rs1353954 5 26560653 [T/C] rs6452345 5 26568243 [T/C] rs10520910 5 26570795 [T/C] rs10520911 5 26573377 [A/G] rs1353956 5 26576539 [A/G] rs16895842 5 26577401 [T/C] rs2319698 5 26589040 [A/G] rs2173689 5 26599566 [T/C] rs10942181 5 26602131 [T/C] rs12654244 5 26602765 [T/C] rs1604097 5 26602880 [A/G] rs2874065 5 26605393 [A/G] rs6896582 5 26606431 [A/G] rs10044376 5 26606877 [A/G] rs7703299 5 26624392 [T/G] rs10038143 5 26631980 [T/C] rs9293243 5 26636294 [A/C] rs6865505 5 26637115 [T/C] rs9687924 5 26637996 [A/G] rs6860010 5 26643591 [T/C] rs6452349 5 26647400 [A/G] rs16895914 5 26652610 [T/C] rs1390638 5 26655797 [A/G] rs6863131 5 26662394 [A/G] rs7445628 5 26669238 [T/G] rs10942193 5 26673835 [A/G] rs7704150 5 26674798 [T/C] rs16895951 5 26675343 [A/C] rs10473810 5 26675352 [T/C] rs3846552 5 26683956 [T/C] rs13164823 5 26688754 [T/C] rs16895967 5 26692369 [T/G] rs11951644 5 26697461 [T/C] rs2132542 5 26699956 [T/C] rs13171386 5 26705812 [A/G] rs10462305 5 26722431 [T/C] rs16895993 5 26722785 [T/C] rs7737624 5 26723311 [A/G] rs4360003 5 26726226 [A/G] rs10068357 5 26727405 [T/G] rs1015610 5 26736006 [A/G] rs10045386 5 26737458 [T/C] rs12656933 5 26737723 [T/C] rs17188971 5 26751379 [T/C] rs1505054 5 26752242 [A/G] rs13356265 5 26755279 [T/G] rs1505044 5 26758206 [T/C] rs16899515 5 26761648 [T/C] rs10056950 5 26762292 [T/C] rs11949563 5 26765497 [T/C] rs10062762 5 26770247 [T/G] rs16896091 5 26785851 [T/C] rs6862526 5 26787013 [A/G] rs2036569 5 26788638 [A/G] rs13163090 5 26788771 [A/C] rs16874804 5 26789357 [T/C] rs1505051 5 26804945 [A/G] rs1505053 5 26805069 [A/C] rs12522752 5 26807536 [T/C] rs7722879 5 26808325 [T/C] rs12521749 5 26811257 [T/C] rs2248868 5 26819303 [A/G] rs966986 5 26826645 [T/C] rs10447155 5 26828780 [A/G] rs846946 5 26829452 [A/G] rs3857327 5 26832200 [T/G] rs818734 5 26832888 [A/G] rs17495847 5 26833657 [T/C] rs818739 5 26834436 [T/C] rs257789 5 26837635 [A/C] rs12519694 5 26838935 [A/G] rs190476 5 26840350 [A/G] rs3846559 5 26847198 [A/C] rs10079767 5 26859083 [T/G] rs13167720 5 26862104 [T/C] rs2035281 5 26865301 [A/C] rs4701549 5 26865656 [A/G] rs1479683 5 26866763 [A/C] rs13170179 5 26872598 [T/C] rs13357094 5 26874641 [T/C] rs2170033 5 26877871 [A/G] rs1382932 5 26886584 [T/C] NM_016279 CDH9 Silent rs12658938 5 26888460 [A/G] NM_016279 CDH9 Silent rs6870789 5 26892008 [A/C] NM_016279 CDH9 Silent rs7734956 5 26900903 [T/C] NM_016279 CDH9 Silent rs16896353 5 26901775 [T/C] NM_016279 CDH9 Silent rs6866141 5 26917996 [A/G] NM_016279 CDH9 Silent rs11745103 5 26927356 [T/C] NM_016279 CDH9 Silent rs10072177 5 26927503 [A/G] NM_016279 CDH9 Silent rs9293251 5 26930468 [T/C] NM_016279 CDH9 Silent rs10064442 5 26932005 [A/G] NM_016279 CDH9 Silent rs10473822 5 26937771 [A/C] NM_016279 CDH9 Silent rs6885387 5 26939178 [A/G] NM_016279 CDH9 Silent rs1007586 5 26942758 [A/G] NM_016279 CDH9 Silent rs10078687 5 26944286 [A/G] NM_016279 CDH9 Silent rs6896887 5 26946380 [A/C] NM_016279 CDH9 Silent rs10520931 5 26947954 [T/C] NM_016279 CDH9 Silent rs10074399 5 26949171 [A/G] NM_016279 CDH9 Silent rs13361520 5 26950235 [A/G] NM_016279 CDH9 Silent rs2170039 5 26953337 [A/G] NM_016279 CDH9 Silent rs6871019 5 26961133 [T/C] NM_016279 CDH9 Silent rs13174843 5 26961843 [A/G] NM_016279 CDH9 Silent rs6863714 5 26965781 [T/G] NM_016279 CDH9 Silent rs10942222 5 26970581 [T/C] NM_016279 CDH9 Silent rs9293258 5 26971951 [A/G] NM_016279 CDH9 Silent rs1175232 5 26972230 [T/C] NM_016279 CDH9 Silent rs1175235 5 26975341 [A/G] NM_016279 CDH9 Silent rs1175237 5 26977421 [A/G] NM_016279 CDH9 Silent rs1366462 5 26977780 [A/G] NM_016279 CDH9 Silent rs7719204 5 26978090 [T/C] NM_016279 CDH9 Silent rs2288466 5 26988328 [A/G] NM_016279 CDH9 EXON Missense_A38V rs2288467 5 26988424 [T/C] NM_016279 CDH9 EXON Missense_Y6C rs13354375 5 27000652 [A/C] NM_016279 CDH9 Silent rs2033236 5 27010686 [T/G] NM_016279 CDH9 Silent rs1549641 5 27012531 [A/G] NM_016279 CDH9 Silent rs10461828 5 27022711 [A/C] NM_016279 CDH9 Silent rs16896464 5 27022838 [A/C] NM_016279 CDH9 Silent rs1428656 5 27033902 [T/C] NM_016279 CDH9 Silent rs10073831 5 27049259 [A/G] rs10520932 5 27058101 [A/G] rs6897759 5 27058850 [T/C] rs10078609 5 27059425 [T/C] rs10078908 5 27060004 [A/G] rs10942232 5 27072469 [T/C] rs17567635 5 27083580 [A/G] rs16896509 5 27084863 [A/C] rs10520933 5 27088529 [T/C] rs10057002 5 27099427 [A/G] rs2876847 5 27108052 [A/G] rs10071841 5 27115148 [T/C] rs4527564 5 27125142 [T/G] rs11952975 5 27135351 [T/C] rs10044502 5 27146918 [A/C] rs7717291 5 27153255 [T/C] rs11956267 5 27154889 [T/C] rs12109333 5 27166660 [T/C] rs7732246 5 27167638 [A/G] rs4597930 5 27171542 [T/C] rs4569834 5 27183961 [T/G] rs6880526 5 27191708 [T/C] rs6879518 5 27199033 [T/G] rs11744047 5 27208707 [A/C] rs6886823 5 27231314 [A/G] rs6887000 5 27231407 [A/G] rs7716875 5 27233648 [A/G] rs4318740 5 27237132 [A/G] rs4133220 5 27249348 [A/G] rs4382127 5 27252466 [A/G] rs2329548 5 27260269 [A/G] rs6867193 5 27270133 [A/C] rs7708855 5 27277045 [T/C] rs16896621 5 27297644 [A/C] rs10473829 5 27301522 [T/G] rs2199214 5 27302423 [T/C] rs961208 5 27308254 [T/G] rs13167049 5 27308663 [T/C] rs34505 5 27328631 [T/C] rs2329426 5 27343904 [T/C] rs12188777 5 27352499 [T/G] rs6869003 5 27361816 [T/C] rs3846564 5 27369088 [A/G] rs325355 5 27373862 [T/G] rs170519 5 27376682 [T/G] rs6872538 5 27378322 [A/C] rs10065280 5 27379706 [A/G] rs2434677 5 27388778 [A/G] rs2434678 5 27390548 [A/C] rs6866494 5 27401935 [A/G] rs4634319 5 27418887 [A/G] rs7732187 5 27424981 [T/C] rs6452383 5 27437931 [A/C] rs4421076 5 27447863 [A/G] rs11744184 5 27449824 [A/G] rs16896818 5 27454710 [T/C] rs6894886 5 27456212 [A/G] rs16896822 5 27457278 [A/G] rs10805800 5 27464184 [A/G] rs12655436 5 27478198 [T/C] NR_038848 PURPL Silent rs12653531 5 27479752 [A/C] NR_038848 PURPL Silent rs10053485 5 27497914 [T/C] rs7702167 5 27509320 [T/C] rs16896876 5 27523340 [T/G] rs6866687 5 27525292 [T/C] rs10473843 5 27529751 [A/G] rs10213971 5 27532751 [T/G] rs2329628 5 27539490 [T/C] rs4701557 5 27539756 [A/G] rs17526423 5 27547030 [T/G] rs6870385 5 27559659 [A/C] rs2329646 5 27570571 [T/C] rs11953669 5 27577544 [T/G] rs10520936 5 27583734 [A/G] rs10053615 5 27590789 [A/G] rs4235543 5 27598537 [T/G] rs11743297 5 27612534 [T/C] rs10461669 5 27622177 [A/G] rs12188974 5 27623650 [T/G] rs7445307 5 27659111 [T/C] rs7721317 5 27660532 [T/C] rs7444723 5 27662620 [A/C] rs4867530 5 27671869 [T/C] rs6859290 5 27684515 [T/C] rs4585457 5 27699870 [T/C] rs4242128 5 27708038 [A/G] rs12651876 5 27714105 [A/G] rs13358613 5 27714885 [A/C] rs4510599 5 27719260 [A/C] rs4379207 5 27720584 [T/C] rs4867154 5 27723087 [A/C] rs4867155 5 27723520 [T/C] rs4382181 5 27726745 [A/G] rs4642381 5 27729100 [T/C] rs7702896 5 27743375 [T/C] rs10454836 5 27748053 [T/C] rs6865311 5 27769954 [T/C] rs6450563 5 27770554 [A/G] rs4254924 5 27773823 [A/C] rs13170401 5 27780690 [A/C] rs13166968 5 27788565 [T/C] rs4516860 5 27792192 [T/C] rs6868258 5 27793344 [T/C] rs6889876 5 27804605 [T/C] rs4074741 5 27817189 [A/G] rs7710218 5 27820172 [T/C] rs4373290 5 27823651 [A/G] rs6862995 5 27824645 [A/G] rs7709151 5 27825557 [A/C] rs11745185 5 27827756 [A/G] rs10062061 5 27837594 [A/C] rs13158156 5 27837898 [T/C] rs7717247 5 27839258 [A/C] rs13163323 5 27846167 [A/G] rs6884792 5 27858188 [A/C] rs4385219 5 27858577 [A/G] rs7708565 5 27862523 [A/C] rs4371767 5 27863084 [T/C] rs10043413 5 27863479 [T/C] rs4867034 5 27873179 [T/C] rs9292229 5 27875181 [T/C] rs10069219 5 27877131 [T/C] rs1981979 5 27896789 [A/G] rs7445766 5 27897183 [A/G] rs13361346 5 27907050 [A/G] rs1991500 5 27907713 [T/C] rs10045279 5 27913746 [A/G] rs1428589 5 27914927 [T/C] rs11958546 5 27924360 [A/C] rs13153124 5 27932273 [A/G] rs13153654 5 27932380 [A/G] rs1366436 5 27935737 [A/C] rs10520938 5 27935822 [A/G] rs16897223 5 27947512 [T/C] rs10472596 5 27947537 [A/G] rs10520937 5 27947751 [A/G] rs11739378 5 27949271 [T/C] rs30809 5 27952031 [T/G] rs13159803 5 27952573 [T/G] rs9292235 5 27953113 [T/C] rs2876935 5 27969709 [T/C] rs919329 5 27973753 [A/C] rs6880598 5 27980523 [A/G] rs10075153 5 27982697 [A/G] rs10070047 5 27983106 [T/C] rs4537065 5 27987104 [A/G] rs373087 5 27988819 [A/G] rs2876936 5 27992491 [T/C] rs4398645 5 28006650 [T/C] rs13354800 5 28009430 [T/C] rs1494617 5 28017229 [T/C] rs7710236 5 28025934 [T/C] rs1603086 5 28028745 [A/C] rs16897331 5 28038878 [T/C] rs11745759 5 28046365 [A/C] rs10044787 5 28053684 [A/C] rs10940703 5 28056225 [A/G] rs1494608 5 28059732 [A/C] rs7711451 5 28084454 [T/C] rs1494605 5 28091661 [T/C] rs2172761 5 28101770 [A/C] rs1494613 5 28102108 [A/G] rs10472601 5 28103888 [T/G] rs10067148 5 28112135 [T/C] rs4293931 5 28118124 [T/C] rs10940704 5 28134334 [T/C] rs11745152 5 28142099 [T/C] rs10472603 5 28142772 [T/C] rs12513515 5 28145629 [A/G] rs4867495 5 28145684 [T/C] rs10070140 5 28147535 [A/G] rs4867504 5 28171050 [A/G] rs4305648 5 28172825 [A/G] rs6893616 5 28183468 [A/G] rs10070878 5 28184320 [T/C] rs7702050 5 28195096 [A/G] rs4612078 5 28207188 [A/G] rs16897444 5 28222685 [T/G] rs1113342 5 28236629 [T/G] rs10472606 5 28239056 [T/C] rs11739270 5 28256995 [A/G] rs10472607 5 28260714 [T/C] rs6859620 5 28261961 [T/C] rs1501681 5 28264465 [A/G] rs2468483 5 28281249 [T/C] rs931739 5 28282431 [A/G] rs2468482 5 28283502 [A/G] rs1393097 5 28286502 [A/G] NR_134265 LINC02103 EXON Silent rs2468477 5 28292827 [A/G] rs2434548 5 28295497 [A/G] rs10056131 5 28302858 [T/G] rs1154991 5 28310093 [T/C] rs16897585 5 28319548 [A/G] rs10061823 5 28319612 [A/G] rs1006069 5 28324647 [A/C] rs1582924 5 28329667 [A/G] rs6867816 5 28344798 [A/G] rs4867532 5 28345493 [A/G] rs10072982 5 28370009 [A/G] rs9292252 5 28380056 [T/C] rs4867536 5 28387558 [A/G] rs4260681 5 28397668 [A/G] rs7735638 5 28402022 [A/G] rs4383731 5 28422193 [T/C] rs10076533 5 28444697 [A/G] rs13355546 5 28464893 [A/G] rs6889117 5 28465895 [T/G] rs7446953 5 28472761 [A/C] rs9292257 5 28477112 [T/C] rs11953455 5 28478206 [A/G] rs6891511 5 28489162 [A/G] rs4266409 5 28489325 [A/G] rs7730170 5 28494582 [A/G] rs7712228 5 28494602 [T/C] rs10940731 5 28495829 [A/C] rs9292261 5 28498983 [T/C] rs9986277 5 28500714 [A/C] rs10472638 5 28513267 [T/C] rs10472639 5 28513392 [T/C] rs10472643 5 28548829 [T/C] rs4867568 5 28549181 [T/C] rs10045332 5 28560977 [A/C] rs9292272 5 28561546 [A/G] rs9292273 5 28573939 [T/C] rs10076497 5 28581874 [T/C] rs6450652 5 28621293 [A/G] rs4389700 5 28621394 [A/G] rs7705800 5 28621926 [A/G] rs10039017 5 28627343 [T/C] rs7710054 5 28628417 [A/G] rs4368739 5 28629677 [A/G] rs10940741 5 28630178 [A/G] rs7708266 5 28631376 [T/C] rs6865063 5 28635825 [T/C] rs4867149 5 28636352 [A/G] rs9292278 5 28640898 [T/G] rs13356614 5 28644794 [A/G] rs13357735 5 28646108 [A/G] rs6450656 5 28648576 [A/C] rs4527615 5 28652860 [A/C] rs12659954 5 28653504 [T/C] rs2042319 5 28662328 [T/C] rs13166838 5 28664932 [T/C] rs11950597 5 28665804 [T/G]