Files
The Files page provides access to the output files for each sample analysis.
| • |
|
| • | VCF Files—Variant calls in the VCF (*.vcf.gz) file format. |
| • | Genome VCF Files—Variants, references, and no calls for all sites in the genome VCF (gVCF) file format. |
| • | Summary File—Statistics for each sample. |
| • | BAM |
| • | VCF Files |
| • | Genome VCF Files |
| • | Summary File |
The following is the complete list of output files:
|
File name |
||||||||||||
|
<SampleName>-replay.json |
||||||||||||
|
<SampleName>.time_metrics.csv |
||||||||||||
|
<SampleName>.wgs_contig_mean_cov.csv |
||||||||||||
|
<SampleName>.wgs_hist.csv |
||||||||||||
|
<SampleName>.wgs_overall_mean_cov.csv |
||||||||||||
|
<SampleName>.wgs_ploidy.csv |
||||||||||||
|
appVersion.log |
||||||||||||
|
stdout.log |
||||||||||||
|
If output format is set to BAM, the following Map/Align files are generated |
||||||||||||
|
<SampleName>.mapping_metrics.csv |
||||||||||||
|
<SampleName>.bam |
||||||||||||
|
<SampleName>.bam.bai |
||||||||||||
|
<SampleName>.bam.md5sum |
||||||||||||
|
If output format is set to CRAM, the following Map/Align files are generated |
||||||||||||
|
<SampleName>.mapping_metrics.csv |
||||||||||||
|
<SampleName>.cram |
||||||||||||
|
<SampleName>.crai |
||||||||||||
|
If small variant calling is enabled, the following files are generated |
||||||||||||
|
<SampleName>.hard-filtered.vcf.gz |
||||||||||||
|
<SampleName>.hard-filtered.vcf.gz.md5sum |
||||||||||||
|
<SampleName>.hard-filtered.vcf.gz.tbi |
||||||||||||
|
<SampleName>.vc_metrics.csv |
||||||||||||
|
<SampleName>.vcf.gz |
||||||||||||
|
<SampleName>.vcf.gz.md5sum |
||||||||||||
|
<SampleName>.vcf.gz.tbi |
||||||||||||
|
If CNV is enabled, the following files are generated |
||||||||||||
|
CNV VCF (including TBI and md5sum) |
||||||||||||
|
Segmentation files
|
||||||||||||
|
Target count files
|
||||||||||||
|
Diploid files
|
||||||||||||
|
<SampleName>.tn.bw |
||||||||||||
|
<SampleName>.tn.tsv |
||||||||||||
|
<SampleName>.improper.pairs.bw |
||||||||||||
|
If Expansion Hunter is enabled, the following files are generated |
||||||||||||
|
<SampleName>.repeats.bam |
||||||||||||
|
<SampleName>.repeats.vcf.gz |
||||||||||||
|
<SampleName>.repeats.vcf.gz.tbi |
||||||||||||
|
If SV (Manta) is enabled, the following files are generated |
||||||||||||
|
<SampleName>.sv.vcf.gz |
||||||||||||
|
<SampleName>.sv.vcf.gz.tbi |
||||||||||||
|
<SampleName>.sv_metrics.csv |
||||||||||||
|
If Nirvana is enabled, each VCF has an accompanying annotation file: |
||||||||||||
|
<SampleName>.annotations.json.gz |
||||||||||||
|
<SampleName>.annotations.json.gz.jsi |
||||||||||||
|
If MD5 is enabled, an md5sums.txt is generated |