CNV Caller Options
The following options are available for the CNV Caller.
|
Name |
Description |
Command Line Equivalent |
Value |
|---|---|---|---|
|
cnv-blacklist-bed |
Regions to blacklist for CNV processing. |
--cnv-blacklist-bed |
|
|
cnv-cbs-alpha |
Significance level for the test to accept change points. Default is 0.01. |
--cnv-cbs-alpha |
|
|
cnv-cbs-eta |
Type I error rate of the sequential boundary for early stopping when using the permutation method. Default is 0.05. |
--cnv-cbs-eta |
|
|
cnv-cbs-kmax |
Maximum width of smaller segment for permutation. Default is 25. |
--cnv-cbs-kmax |
|
|
cnv-cbs-min-width |
Minimum number of markers for a changed segment. Default is 2. |
--cnv-cbs-min-width |
|
|
cnv-cbs-nmin |
Minimum length of data for maximum statistic approximation. Default is 200. |
--cnv-cbs-nmin |
|
|
cnv-cbs-nperm |
Number of permutations used for p-value computation. Default is 10000. |
--cnv-cbs-nperm |
|
|
cnv-cbs-trim |
Proportion of data to be trimmed for variance calculations. Default is 0.025. |
--cnv-cbs-trim |
|
|
cnv-counts-method |
Overlap method for counting alignment. |
--cnv-counts-method |
midpoint / start / overlap |
|
cnv-enable-gcbias-correction |
Controls GC bias correction. |
--cnv-enable-gcbias-correction |
true/false |
|
cnv-enable-gcbias-smoothing |
Controls smoothing of the GC bias correction across adjacent GC bins with an exponential kernel. Default is true. |
--cnv-enable-gcbias-smoothing |
true/false |
|
cnv-enable-plots |
Enable/disable generation of plots. Default is false. |
--cnv-enable-plots |
true/false |
|
cnv-enable-ref-calls |
When true, copy neutral (REF) calls are included in the output VCF. |
--cnv-enable-ref-calls |
true/false |
|
cnv-enable-self-normalization |
Enable/disable self-normalization. |
--cnv-enable-self-normalization |
true/false |
|
cnv-enable-tracks |
Enable/disable generation of track files that can be imported into IGV for viewing. Default is true. |
--cnv-enable-tracks |
true/false |
|
cnv-extreme-percentile |
Extreme median percentile value at which to filter out samples. Default is 2.5. |
--cnv-extreme-percentile |
|
|
cnv-filter-bin-support-ratio |
Filters out a candidate event if the span of supporting bins is less than the specified ratio with respect to the overall event length. The default ratio is 0.2 (20% support). |
--cnv-filter-bin-support-ratio |
|
|
cnv-filter-copy-ratio |
Minimum copy ratio threshold value centered about 1.0 at which a reported event is marked as PASS in the output VCF file. Default is 0.2 |
--cnv-filter-copy-ratio |
|
|
cnv-filter-de-novo-quality |
Phred-scale threshold for calling an event as de novo in the proband. |
--cnv-filter-de-novo-quality |
|
|
cnv-filter-length |
Minimum event length in bases at which a reported event is marked as PASS in the output VCF file. Default is 10000. |
--cnv-filter-length |
|
|
cnv-filter-qual |
The QUAL value at which a reported event is marked as PASS in the output VCF file. |
--cnv-filter-qual |
|
|
cnv-input |
CNV input file instead of a BAM. Either target.counts.gz or tn.tsv.gz (for de novo). |
--cnv-input |
|
|
cnv-interval-width |
Width of the sampling interval for CNV WGS processing. |
--cnv-wgs-interval-width |
|
|
cnv-matched-normal |
Target counts file of the matched normal sample. |
--cnv-matched-normal |
|
|
cnv-max-percent-zero-samples |
Threshold for filtering out targets with too many zero coverage samples. Default is 5%. |
--cnv-max-percent-zero-samples |
|
|
cnv-max-percent-zero-targets |
Threshold for filtering out samples with too many zero coverage targets. Default is 5%. |
--cnv-max-percent-zero-targets |
|
|
cnv-merge-distance |
Maximum segment gap allowed for merging segments. |
--cnv-merge-distance |
|
|
cnv-merge-threshold |
The maximum segment mean difference at which two adjacent segments should be merged. The segment mean is represented as a linear copy ratio value. |
--cnv-merge-threshold |
|
|
cnv-min-mapq |
Minimum MAPQ for alignment to be counted. |
--cnv-min-mapq |
|
|
cnv-normals-file |
A single file to be used in the panel of normals. Can be specified multiple times, once for each file. |
--cnv-normals-file |
|
|
cnv-normals-list |
A panel of normals file. |
--cnv-normals-list |
|
|
cnv-num-gc-bins |
Number of bins for GC bias correction. Each bin represents the GC content percentage. Default is 25. |
--cnv-num-gc-bins |
10 / 20 / 25/ 50 / 100 |
|
cnv-ploidy |
The normal ploidy value. Used for estimation of the copy number value emitted in the output VCF file. Default is 2. |
--cnv-ploidy |
|
|
cnv-qual-length-scale |
Bias weighting factor to adjust QUAL estimates for segments with longer lengths. Advanced option that should not have to be modified. Default is 0.9303 (2-0.1). |
--cnv-qual-length-scale |
|
|
cnv-qual-noise-scale |
Bias weighting factor to adjust QUAL estimates based on sample variance. Advanced option that should not have to be modified. Default is 1.0. |
--cnv-qual-noise-scale |
|
|
cnv-segmentation-mode |
Segmentation algorithm to perform. |
--cnv-segmentation-mode |
cbs / slm / aslm |
|
cnv-skip-contig-list |
A comma-separated list of contig identifiers to skip when generating intervals for WGS analysis. The default contigs that are skipped, if not specified, are "chrM,MT,m,chrm". |
--cnv-wgs-skip-contig-list |
|
|
cnv-slm-eta |
Baseline probability that the mean process changes its value. Default is 1e-5. |
--cnv-slm-eta |
|
|
cnv-slm-fw |
Minimum number of data points for a CNV to be emitted. Default is 0. |
--cnv-slm-fw |
|
|
cnv-slm-omega |
Scaling parameter modulating relative weight between experimental/biological variance. Default is 0.3. |
--cnv-slm-omega |
|
|
cnv-slm-stepeta |
Distance normalization parameter. The default value is 10000. Only valid for “HSLM”. |
--cnv-slm-stepeta |
|
|
cnv-target-bed |
A properly formatted BED file that specifies the target intervals to sample coverage over. For use in WES analysis. |
--cnv-target-bed |
|
|
cnv-target-factor-threshold |
Percentile of panel-of-normals medians used to filter out targets. The default value is 1% for whole genome processing and 10% for targeted sequencing processing. |
--cnv-target-factor-threshold |
|
|
cnv-truncate-threshold |
Extreme outliers are truncated based on this percent threshold. Default is 0.1%. |
--cnv-truncate-threshold |
|
|
cnv-use-somatic-vc-vaf |
Use somatic SNV VAFs from VC to help determine purity and ploidy. |
-cnv-use-somatic-vc-vaf |