Variant Caller Options
The following options control the variant caller stage of the DRAGEN host software.
• | --enable-variant-caller |
Set --enable-variant-caller to true to enable the variant caller stage for the DRAGEN pipeline.
• | --vc-target-bed |
This is an optional command line input that restricts processing of the small variant caller, target bed related coverage, and callability metrics to regions specified in a BED file. The BED file is a text file containing at least three tab-delimited columns. The first three columns are chromosome, start position, and end position, respectively. The positions are zero-based. For example:
For example:
# header information
chr11 0 246920
chr11 255660 255661
• | --vc-target-bed-padding |
This is an optional command line input that can be used to pad all of the target BED regions with the specified value. For example, if a BED region is 1:1000-2000 and a padding value of 100 is used, it is equivalent to using a BED region of 1:900-2100 and a padding value of 0. Any padding added to --vc-target-bed-padding is used by the small variant caller and by the target bed coverage/callability reports. The default padding is 0.
• | --vc-sample-name |
The --vc-sample-name option is deprecated. In end-to-end germline mode (with FASTQ input), the variant caller uses the RGSM value as the sample name. In end-to-end somatic mode, --RGSM-tumor can be used to specify the sample name of the tumor sample. In stand-alone mode (with BAM input), the variant caller uses the RGSM value from the BAM header as the sample name. In somatic mode, the RGSM value from a tumor BAM is as the tumor sample name.
• | --vc-target-coverage |
The --vc-target-coverage option specifies the target coverage for down-sampling. The default value is 500 for germline mode and 50 for somatic mode.
• | --vc-enable-gatk-acceleration |
If --vc-enable-gatk-acceleration is set to true, the variant caller runs in GATK mode (concordant with GATK 3.7 in germline mode and GATK 4.0 in somatic mode).
• | --vc-remove-all-soft-clips |
If --vc-remove-all-soft-clips is set to true, the variant caller does not use soft clips of reads to determine variants.
• | --vc-decoy-contigs |
The --vc-decoy-contigs option specifies a comma-separated list of contigs to skip during variant calling. This option can be set in the configuration file.
• | --vc-enable-decoy-contigs |
If --vc-enable-decoy-contigs is set to true, variant calls on the decoy contigs are enabled. The default value is false.
• | --vc-enable-phasing |
The –vc-enable-phasing option enables variants to be phased when possible. The default value is true.
• | --vc-enable-phasing |
The –vc-enable-phasing option enables variants to be phased when possible. The default value is true.
• | --vc-enable-vcf-output |
The –vc-enable-vcf-output option enables VCF file output during a gVCF run. The default value is false.