Methylation Cytosine and M-Bias Reports

To generate a genome-wide cytosine methylation report, set --methylation-generate-cytosine-report to true. The position and strand of each C in the genome are given in the first three fields of the report. A record with a '-' in the strand field is for a G in the reference FASTA. The counts of methylated and unmethylated C's covering the position are given in the fourth and fifth fields, respectively. The C-context in the reference (CG, CHG, or CHH) is given in the sixth field, and the trinucleotide sequence context is given in the last field (eg, CCC, CGT, CGA, etc). The cytosine report only includes records forThe following is an example cytosine report record:

chr2    24442367        +          18           0             CG          CGC

To generate an M-bias report, set --methylation-generate-mbias-report to true. This report contains three tables for single-ended data with one table for each C-context, and six tables for paired-end data. Each table is a series of records, with one record per read base position. For example, the first record for the CHG table contains the counts of methylated C's (field 2) and unmethylated C's (field 3) that occur in the first read base position, restricting to those reads in which the first base is aligned to a CHG location in the genome. Each record of a table also includes the percent methylated C bases (field 4) and the sum of methylated and unmethylated C counts (field 5).

The following is an example M-bias record for read base position 10:

       10      7335    2356    75.69   9691

For data sets with paired-end reads that overlap, both the Cytosine and M-bias reports skip reporting any C’s in the second read that overlaps the first read. In addition, 1-based coordinates are used for positions in both reports.

To match the bismark_methylation_extractor cytosine and M-bias reports generated by Bismark version 0.19.0, set the --methylation-match-bismark option to true. The ordering of records in Bismark and DRAGEN cytosine reports may differ. DRAGEN reports are sorted by genomic position.