VCF INFO Fields
ID |
Description |
---|---|
IMPRECISE |
Flag indicating that the structural variation is imprecise, ie, the exact breakpoint location is not found |
SVTYPE |
Type of structural variant |
SVLEN |
Difference in length between REF and ALT alleles |
END |
End position of the variant described in this record |
CIPOS |
Confidence interval around POS |
CIEND |
Confidence interval around END |
CIGAR |
CIGAR alignment for each alternate indel allele |
MATEID |
ID of mate breakend |
EVENT |
ID of event associated to breakend |
HOMLEN |
Length of base pair identical homology at event breakpoints |
HOMSEQ |
Sequence of base pair identical homology at event breakpoints |
SVINSLEN |
Length of insertion |
SVINSSEQ |
Sequence of insertion |
LEFT_SVINSSEQ |
Known left side of insertion for an insertion of unknown length |
RIGHT_SVINSSEQ |
Known right side of insertion for an insertion of unknown length |
PAIR_COUNT |
Read pairs supporting this variant where both reads are confidently mapped |
BND_PAIR_COUNT |
Confidently mapped reads supporting this variant at this breakend (mapping may not be confident at remote breakend) |
UPSTREAM_PAIR_COUNT |
Confidently mapped reads supporting this variant at the upstream breakend (mapping may not be confident at downstream breakend) |
DOWNSTREAM_PAIR_COUNT |
Confidently mapped reads supporting this variant at this downstream breakend (mapping may not be confident at upstream breakend) |
BND_DEPTH |
Read depth at local translocation breakend |
MATE_BND_DEPTH |
Read depth at remote translocation mate breakend |
JUNCTION_QUAL |
If the SV junction is part of an EVENT (ie, a multi-adjacency variant), this field provides the QUAL value for the adjacency in question only |
SOMATIC |
Flag indicating a somatic variant |
SOMATICSCORE |
Somatic variant quality score |
JUNCTION_SOMATICSCORE |
If the SV junction is part of an EVENT (ie, a multi-adjacency variant), this field provides the SOMATICSCORE value for the adjacency in question only |
CONTIG |
Assembled contig sequence, if the variant is not imprecise (with ‑‑outputContig) |
DUPSVLEN |
Length of duplicated reference sequence |
DUPHOMLEN |
Length of base pair identical homology at event breakpoints excluding duplicated reference sequence |
DUPHOMSEQ |
Sequence of base pair identical homology at event breakpoints excluding duplicated reference sequence |
DUPSVINSLEN |
Length of inserted sequence after duplicated reference sequence |
DUPSVINSSEQ |
Inserted sequence after duplicated reference sequence |
NotDiscovered |
Variant candidate specified by the user and not discovered from input sequencing data |
UserInputId |
Variant ID from user input VCF |
KnownSVScoring |
Variant is associated with a user specified input variant, therefore scoring and filtration criteria are relaxed under a stronger prior assumption of truth |