Modify Variant Grid Views
The Variant Grid provides a configurable view of data in a case. You can create new filtered views and customize the column configuration in the grid.
Note
Modifying how data appear in the Variant Grid only affects how information is arranged in the table. Modifying views does not change the underlying data.
The test definition specifies one or more default tabs that provide filtered views of the data. Each view resides on a different tab with a unique set of filters. The tab lists the name of the filter and the number of unreviewed variants in the tab.
You can create an unlimited number of tabs for as many additional views as necessary. For more information about configuring new filters tabs, see Create New Filters in the Variant Grid.
Use the View variant by status menu to further limit the display of variants by flag or review status.
The status menu displays icons corresponding to the selected options.
Show, hide, and reorder columns in the grid for a custom view of data in the case.
| 1. | Select the All Columns menu and then perform any of the following actions: |
| • | Select a column name checkbox to show the column in the variant grid. |
| • | Drag the column selector to specify the order of the columns in the grid. |
The top annotation is the first column, and the bottom annotation is the last.
| • | Clear the checkbox to hide a column. |
| 2. | Select Apply. |
NOTE
The Flag, Status, Linked, and IGV columns are always visible and cannot be hidden or moved.
The variant grid default sort is by Overlap, followed by Position. Each tab can support a different custom sort that includes up to 10 columns. Custom sort configuration is per-tab and persists across sessions.
Sorted columns are indicated by an arrow in the column heading. If more than one column is sorted, a number indicates the sort level
| • | To sort a column, click the column heading. |
| • | To add an additional level of sort, hold the shift key and click a different column heading. Click the heading again to reverse the sort for the column. |
| • | To clear the sort, select any column without holding the shift key. |