Illumina Stranded Total RNA Prep Ligation with Ribo-Zero Plus
Illumina Ribo-Zero Plus rRNA Depletion Kit
Quantity |
Reagent |
Description |
Storage |
---|
1 |
DTE |
CTE Dilution Tube |
Room temperature |
1 |
DTA |
CTA Dilution Tube |
Room temperature |
1 |
DTL |
CTL Dilution Tube |
Room temperature |
1 |
RRB |
rRNA Removal Beads |
2°C to 8°C |
Library Prep Ribo-Zero Box
You will receive one of the following boxes, depending on the workflow. The box also contains plate barcode labels.
Ribo-Zero H/M/R
Quantity |
Reagent |
Description |
Storage |
---|
1 |
RBB |
rRNA Binding Buffer |
-25°C to -15°C |
1 |
RRM |
rRNA Removal Mix |
-25°C to -15°C |
1 |
ELB |
Elution Buffer |
2°C to 8°C |
1 |
EPH |
Elute, Prime, Fragment High Mix |
-25°C to -15°C |
Ribo-Zero Gold
Quantity |
Reagent |
Description |
Storage |
---|
1 |
RBB |
rRNA Binding Buffer |
-25°C to -15°C |
1 |
RRM G |
rRNA Removal Mix - Gold |
-25°C to -15°C |
1 |
ELB |
Elution Buffer |
2°C to 8°C |
1 |
EPH |
Elute, Prime, Fragment High Mix |
-25°C to -15°C |
Ribo-Zero Plant
Quantity |
Reagent |
Description |
Storage |
---|
1 |
RBB |
rRNA Binding Buffer |
-25°C to -15°C |
1 |
RRM P |
rRNA Removal Mix - Plant |
-25°C to -15°C |
1 |
ELB |
Elution Buffer |
2°C to 8°C |
1 |
EPH |
Elute, Prime, Fragment High Mix |
-25°C to -15°C |
Ribo-Zero Globin
Quantity |
Reagent |
Description |
Storage |
---|
1 |
RBB |
rRNA Binding Buffer |
-25°C to -15°C |
1 |
GRM |
Globin Removal Mix |
-25°C to -15°C |
1 |
ELB |
Elution Buffer |
2°C to 8°C |
1 |
EPH |
Elute, Prime, Fragment High Mix |
-25°C to -15°C |
Quantity |
Reagent |
Description |
---|
1 |
ATL |
A-Tailing Mix |
1 |
CTA |
A-Tailing Control |
1 |
CTE |
End Repair Control |
1 |
CTL |
Ligation Control |
1 |
LIG |
Ligation Mix |
1 |
RSB |
Resuspension Buffer |
1 |
STL |
Stop Ligation Buffer |
Core Library Prep Box 2, Store at -25°C to -15°C
Quantity |
Reagent |
Description |
---|
1 |
PMM |
PCR Master Mix |
1 |
PPC |
PCR Primer Cocktail |
1 |
FSA |
First Strand Synthesis Act D Mix |
1 |
SMM |
Second Strand Marker Master Mix |
TruSeq Stranded Total RNA Library Prep (96 Samples))
Library Prep Box 1
Quantity |
Reagent |
Description |
Storage |
---|
1 |
DTE |
CTE Dilution Tube |
Room temperature |
1 |
DTA |
CTA Dilution Tube |
Room temperature |
1 |
DTL |
CTL Dilution Tube |
Room temperature |
2 |
RRB |
rRNA Removal Beads |
2°C to 8°C |
Library Prep Ribo-Zero Box
You will receive two of one of the following boxes, depending on the workflow. The box also contains plate barcode labels.
Library Preparation H/M/R (48 Samples)
Quantity |
Reagent |
Description |
Storage |
---|
2 |
RBB |
rRNA Binding Buffer |
-25°C to -15°C |
2 |
RRM |
rRNA Removal Mix |
-25°C to -15°C |
2 |
ELB |
Elution Buffer |
2°C to 8°C |
2 |
EPH |
Elute, Prime, Fragment High Mix |
-25°C to -15°C |
Library Preparation Gold (48 Samples)
Quantity |
Reagent |
Description |
Storage |
---|
2 |
RBB |
rRNA Binding Buffer |
-25°C to -15°C |
2 |
RRM G |
rRNA Removal Mix - Gold |
-25°C to -15°C |
2 |
ELB |
Elution Buffer |
2°C to 8°C |
2 |
EPH |
Elute, Prime, Fragment High Mix |
-25°C to -15°C |
Library Preparation Plant (48 Samples)
Quantity |
Reagent |
Description |
Storage |
---|
2 |
RBB |
rRNA Binding Buffer |
-25°C to -15°C |
2 |
RRM P |
rRNA Removal Mix - Plant |
-25°C to -15°C |
2 |
ELB |
Elution Buffer |
2°C to 8°C |
2 |
EPH |
Elute, Prime, Fragment High Mix |
-25°C to -15°C |
Library Preparation Globin (48 Samples)
Quantity |
Reagent |
Description |
Storage |
---|
2 |
RBB |
rRNA Binding Buffer |
-25°C to -15°C |
2 |
GRM |
Globin Removal Mix |
-25°C to -15°C |
2 |
ELB |
Elution Buffer |
2°C to 8°C |
2 |
EPH |
Elute, Prime, Fragment High Mix |
-25°C to -15°C |
Quantity |
Reagent |
Description |
---|
2 |
ATL |
A-Tailing Mix |
2 |
CTA |
A-Tailing Control |
2 |
CTE |
End Repair Control |
2 |
CTL |
Ligation Control |
2 |
LIG |
Ligation Mix |
2 |
RSB |
Resuspension Buffer |
2 |
STL |
Stop Ligation Buffer |
Core Library Prep Box 2, Store at -25°C to -15°C
Quantity |
Reagent |
Description |
---|
2 |
PMM |
PCR Master Mix |
2 |
PPC |
PCR Primer Cocktail |
2 |
FSA |
First Strand Synthesis Act D Mix |
2 |
SMM |
Second Strand Marker Master Mix |