Variant Caller Options
The following options are in the Variant Caller section of the configuration file. For more information on these options, see Variant Caller Options.
|
Name |
Description |
Command Line Equivalent |
Value |
|---|---|---|---|
|
dn-cnv-vcf |
Joint structural variant VCF from the CNV calling step. If omitted, checks with overlapping copy number variants are skipped. |
--dn-cnv-vcf |
|
|
dn-input-vcf |
Joint small variant VCF de novo calling step to be filtered |
--dn-input-vcf |
|
|
dn-output-vcf |
File location to which the filtered VCF should be written. If not specified, the input VCF is overwritten. |
--dn-output-vcf |
|
|
dn-sv-vcf |
Joint structural variant VCF from the SV calling step. If omitted, checks with overlapping structural variants are skipped. |
--dn-sv-vcf |
|
|
enable-combinegvcfs |
Enable/disable combine gVCF run. |
--enable-combinegvcfs |
true/false |
|
enable-joint-genotyping |
To enable combine gVCF run, set to true. |
--enable-joint-genotyping |
true/false |
|
enable-multi-sample-gvcf |
Enable/disable generation of a multisample gVCF file. If set to true, requires a combined gVCF file as input. |
--enable-multi-sample-gvcf |
true/false |
|
enable-sv |
Enable/disable structural variant caller. Default is false. |
--enable-sv |
true/false |
|
enable-vlrd |
Enable/disable Virtual Long Read Detection. |
--enable-vlrd |
true/false |
|
panel-of-normals |
The path to the panel of normals VCF file. |
--panel-of-normals |
|
|
pedigree-file |
Specific to joint calling. The path to a PED pedigree file containing a structured description of the familial relationships between samples. The pedigree file can contain trios. Only pedigree files that contain trios are supported. |
--pedigree-file |
|
|
qc-snp-DeNovo-quality-threshold |
The threshold for counting and reporting De Novo SNP variants. |
--qc-snp-DeNovo-quality-threshold |
|
|
qc-indel-DeNovo-quality-threshold |
The threshold for counting and reporting De Novo INDEL variants. |
--qc-indel-DeNovo-quality-threshold |
|
|
variant |
The path to a single gVCF file. Multiple --variant options can be used on the command line, one for each gVCF. Up to 500 gVCFs are supported. |
--variant |
|
|
variant-list |
The path to a file containing a list of input gVCF files, one file per line, that need to be combined. |
--variant-list |
|
|
vc-af-call-threshold |
Set the allele frequency call threshold to emit a call in the VCF if the AF filter is enabled. The default is 0.01. |
--vc-af-call-threshold |
|
|
vc-af-filter-threshold |
Set the allele frequency filter threshold to mark emitted VCF calls as filtered if the AF filter is enabled. The default is 0.05. |
--vc-af-filter-threshold |
|
|
vc-callability-normal-threshold |
The normal sample coverage threshold for a site to be considered callable in the somatic callable regions report. |
--vc-callability-normal-thresh |
|
|
vc-callability-tumor-threshold |
The tumor sample coverage threshold for a site to be considered callable in the somatic callable regions report. |
--vc-callability-tumor-thresh |
|
|
vc-decoy-contigs |
The path to a comma-separated list of contigs to skip during variant calling. |
--vc-decoy-contigs |
|
|
vc-detect-systematic-noise |
Sensitive VCF run mode used when building a systematic noise file. |
--vc-detect-systematic-noise |
true/false |
|
vc-emit-ref-confidence |
To enable base pair gVCF generation, set to BP_RESOLUTION. To enable banded gVCF generation, set to GVCF. |
--vc-emit-ref-confidence |
BP_RESOLUTION / GVCF |
|
vc-enable-af-filter |
Enable/disable the allele frequency filter for somatic mode. Default is false. |
--vc-enable-af-filter |
true/false |
|
vc-enable-baf |
Enable or disable B-allele frequency output. The default is true (enabled). |
--vc-enable-baf |
true/false |
|
vc-enable-decoy-contigs |
Enable/disable variant calls on decoy contigs. Default is false. |
--vc-enable-decoy-contigs |
true/false |
|
vc-enable-gatk-acceleration |
Enable/disable running variant caller in GATK mode. |
--vc-enable-gatk-acceleration |
true/false |
|
vc-enable-liquid-tumor-mode |
Enable/disable liquid tumor mode, which takes account of tumor-in-normal contamination. Default is false (disabled). |
--vc-enable-liquid-tumor-mode |
true/false |
|
vc-enable-non-homref-normal-filter |
Enable/disable the non-homref normal filter for filtering out somatic variants if the normal sample genotype is not homozygous reference. Default is true (enabled). |
--vc-enable-non-homref-normal-filter |
true/false |
|
vc-enable-orientation-bias-filter |
Enable/disable the orientation bias filter. |
--vc-enable-orientation-bias-filter |
true/false |
|
vc-enable-phasing |
Enable variants to be phased when possible. Default is true. |
--vc-enable-phasing |
true/false |
|
vc-enable-roh |
Enable or disable ROH caller and output. Default is true (enabled). |
--vc-enable-roh |
true/false |
|
vc-enable-triallelic-filter |
Enable/disable the multi-allelic filter for somatic mode. Default is true. |
--vc-enable-triallelic-filter |
true/false |
|
vc-enable-vcf-output |
Enables VCF file output during a gVCF run. Default is false. |
--vc-enable-vcf-output |
true/false |
|
vc-forcegt-vcf |
Force genotyping for Germline small variant calling. A .vcf or .vcf.gz file containing a list of small variants is required. |
--vc-forcegt-vcf |
A .vcf or vcf.gz file specifying the small variants to force genotype. |
|
vc-gvcf-gq-bands |
Define GQ bands for gVCF output. Default is 10 20 30 40 60 80. |
--vc-gvcf-gq-bands |
|
|
vc-hard-filter |
Boolean expression for filtering variant calls. Default expression is: DRAGENHardQUAL:all: QUAL < 10.4139;LowDepth:all: DP < 1 |
|
Parameters in the expression can include QD, MQ, FS, MQRankSum, ReadPosRankSum, QUAL, DP, and GQ. |
|
vc-max-reads-per-active-region |
Maximum number of reads per active region for downsampling. Default is 10000. |
--vc-max-reads-per-active-region |
|
|
vc-max-reads-per-active-region-mito |
Maximum number of reads covering a given active region for mitochondrial small variant calling. The default is 40000. |
--vc-max-reads-per-active-region-mito |
|
|
vc-max-reads-per-raw-region |
Maximum number of reads per raw region for downsampling; default is 30000. |
--vc-max-reads-per-raw-region |
|
|
vc-max-reads-per-raw-region-mito |
Maximum number of reads covering a specified raw region for mitochondrial small variant calling. The default is 40000. |
--vc-max-reads-per-raw-region-mito |
|
|
vc-min-base-qual |
Minimum base quality to be considered for variant calling. Default is 10. |
--vc-min-base-qual |
|
|
vc-min-call-qual |
Minimum variant call quality for emitting a call. Default is 3. |
--vc-min-call-qual |
|
|
vc-min-read-qual |
Minimum read quality (MAPQ) to be considered for small variant calling. Default is 1 for germline, 3 for somatic T/N, and 20 for somatic T-only. |
--vc-min-read-qual |
|
|
vc-min-reads-per-start-pos |
Minimum number of reads per start position for downsampling. Default is 10. |
--vc-min-reads-per-start-pos |
|
|
vc-min-tumor-read-qual |
Minimum tumor read quality (MAPQ) to be considered for variant calling. |
|
|
|
vc-orientation-bias-filter-artifacts |
Artifact type to be filtered. An artifact (or an artifact and its reverse compliment) cannot be listed twice. |
--vc-orientation-bias-filter-artifacts |
C/T, G/T,or C/T, G/T, C/A |
|
vc-remove-all-soft-clips |
If set to true, variant caller does not use soft clips of reads to determine variants. Default is false. |
--vc-remove-all-soft-clips |
true/false |
|
vc-roh-blacklist-bed |
Blacklist BED file for ROH. |
--vc-roh-blacklist-bed |
|
|
vc-sq-call-threshold |
Set the SQ call threshold to emit a call in the VCF. The default is 3 for both tumor-normal and tumor-only. |
--vc-sq-call-threshold |
|
|
vc-sq-filter-threshold |
Set the SQ filter threshold to mark emitted VCF calls as filtered. The default is 17.5 for tumor-normal and 6.5 for tumor-only. |
--vc-sq-filter-threshold |
|
|
vc-systematic-noise |
BED file with site-specific systematic noise level to calculate AQ score (systematic noise score). |
--vc-systematic-noise |
|
|
vc-systematic-noise-filter-threshold |
AQ threshold for applying the systematic-noise filter. Default 10 for tumor-normal and 60 for tumor-only. |
--vc-systematic-noise-filter-threshold |
0–100. 10 for tumor-normal, 60 for tumor-only |
|
vc-target-bed |
Target regions BED file. |
--vc-target-bed |
|
|
vc-target-bed-padding |
Can be used to pad all of the target BED regions with the specified value (optional). If specified, is used by the small variant caller. |
--vc-target-bed-padding |
|
|
vc-target-coverage |
Target coverage for downsampling. Default value is 500 for germline and 50 for somatic mode. |
--vc-target-coverage |
|
|
vc-target-coverage-mito |
Maximum number of reads with a start position overlapping any given position for mitochondrial small variant calling. Default value is 40000. |
--vc-target-coverage-mito |
|
|
vc-tin-contam-tolerance |
Maximum tumor-in-normal contamination expected. Setting this to a nonzero value enables liquid tumor mode. The default value is 0.15 if liquid tumor mode is enabled or 0 if it is disabled. |
--vc-tin-contam-tolerance |
|