Association Details
The following tables describe the variant and gene association details.
TruSight Software follows ACMG guidelines for classification.
|
Classification |
Description |
|---|---|
|
Pathogenic (P) |
Segregates with disease in multiple unrelated cases with control data. The variant is in a highly conserved region. Functional studies or other evidence indicate a deleterious effect on gene expression. |
|
Likely Pathogenic (LP) |
Reported in some case studies with or without control data. The variant is in a highly conserved region. Functional studies or other evidence highly suggest a deleterious effect on gene expression. |
|
Variant of Unknown Significance (VUS) |
Nothing about this variant has been reported, or reported information is incomplete or contradictory. |
|
Likely Benign (LB) |
Functionally normal. Reported in a few cases with little or no control data. The variant might be nonconserved and predicted to be tolerated. Based on disease prevalence and penetrance information, the variant frequency is higher than expected in the general population. |
|
Benign (B) |
Functionally normal. Reported at high frequency in control data and does not segregate with disease. The variant might be nonconserved and predicted to be tolerated. |
|
Observed |
A region of homozygosity is observed in the variant. The classification applies to ROH variants only. |
|
Classification |
Description |
|---|---|
|
Expanded |
The number of STRs is increased relative to the reference sequence. |
|
Not Expanded |
The number of STRs is decreased or unchanged relative to the reference sequence. |
TruSight Software follows the Clinical Genome gene-disease evidence guidelines for classification.
|
Classification |
Description |
|---|---|
|
Definitive |
Evidence is repeatedly demonstrated and upheld over time. |
|
Strong |
Evidence has been independently demonstrated in separate studies. |
|
Moderate |
Clinical evidence and supporting experimental evidence are reported in at least one study. |
|
Limited |
At least one variant has plausible genetic evidence to support the association, with or without gene-level experimental data. |
|
Conflicting |
Conflicting evidence that disputes or refutes an assertion of gene-disease association has been reported. |
|
No evidence |
Evidence for a causal role for this gene in this disease has not been reported. |
The disease mode of inheritance.
|
Mode of Inheritance |
Description |
|---|---|
|
Autosomal Dominant |
The gene is on a nonsex chromosome. A single copy of the variant associated with disease is sufficient to cause the disease. |
|
Autosomal Recessive |
The gene is on a nonsex chromosome. Two copies of an abnormal gene must be present for disease to develop. |
|
Autosomal Dominant/Recessive |
A combination of autosomal dominant and autosomal recessive variants are associated with disease. The variant presentation may differ between autosomal dominant and autosomal recessive contexts. |
|
X-Linked Dominant |
A dominant gene is on the X chromosome. |
|
X-Linked Recessive |
A variant in a gene on the X chromosome causes a phenotype to be expressed in males and in females who are homozygous for the gene mutation. |
|
X-Linked Not Specified |
Inheritance of genes on the X chromosome, but it is not known if the gene is dominant or recessive. |
|
Y-Linked |
Inheritance of genes on the Y chromosome. |
|
Complex |
Two heterogenous recessive alleles are present at a locus that can cause disease. |
|
Inconclusive |
The inheritance cannot be determined. |
|
Mitochondrial |
A mutation in mitochondrial DNA. |
|
Unknown |
The mode of inheritance is not known. |
|
Mechanism |
Description |
|---|---|
|
Loss of Function |
The variant association is expected to result in a decrease in function. |
|
Gain of Function |
The variant association is expected to result in an increase in function. |
The following table lists other details about variants in Knowledge Network.
|
Detail |
Description |
|---|---|
|
Penetrance |
The proportion of individuals who carry the variant and express the related disease. |
|
Confidence |
The level of confidence in the causality for the association. |
|
Curator Summary |
The description of the association provided by the curator. |