Enrichment Summary Report
The Enrichment App produces an enrichment summary report in a comma-separated values (CSV) format (*.summary.csv). The file is located in the analysis results folder under Output Files.
NOTE
Some metrics are only reported if they are requested in the sample sheet. For example, the summary report can include different metrics for samples that are flagged as duplicates or not duplicates.
Statistic | Definition | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Sample ID |
IDs of samples reported on in the file. |
||||||||||||
Sample Name |
Names of samples reported on in the file. |
||||||||||||
Run Folder |
Run folders for samples reported on in the file. |
||||||||||||
Reference Genome |
The selected reference genome. |
||||||||||||
Paired End |
Boolean identifies whether the sample is paired-end or single-end. |
||||||||||||
Metrics Version |
The PUMA metrics version. |
||||||||||||
Percent Callability |
The percent of non-N reference positions in targeted regions with a passing genotype call. |
||||||||||||
Percent Autosome Callability |
The percent of non-N reference positions in targeted regions in autosomal chromosomes with a passing genotype call. |
||||||||||||
Metrics Deliverable |
The type of metrics in the summary file. |
||||||||||||
Enrichment Summary Format Version |
The version of metrics in the summary file. |
||||||||||||
Target Manifest |
The target manifest file used for analysis. This file specifies the targeted regions for the aligner and variant caller. |
||||||||||||
Total Length of Targeted Reference |
The total length of the sequenced bases in the target region. |
||||||||||||
Number of Targeted Regions |
The number of target regions in the manifest file. |
||||||||||||
Padding Size |
The length of sequence immediately upstream and downstream of the enrichment targets that is included for a padded target. |
||||||||||||
Target Unique Aligned Reads |
The number of reads that align to the target and are not flagged as duplicates. The statistic does not include the following reads:
|
||||||||||||
Padded Target Unique Aligned Reads |
The number of reads that align to the padded target and are not flagged as duplicates. |
||||||||||||
Unique Read Enrichment |
100* (Targeted unique aligned reads/Unique aligned reads) |
||||||||||||
Padded Unique Read Enrichment |
100* (Padded targeted unique aligned reads/Unique aligned reads) |
||||||||||||
Total PF Reads |
The total number of pass-filter reads for the sample. |
||||||||||||
Total PF Read 1 |
The total number of pass-filter reads for Read 1. |
||||||||||||
Total PF Read 2 |
The total number of pass-filter reads for Read 2. |
||||||||||||
Unique PF Reads |
The total number of pass-filter reads that are aligned and are not flagged as duplicates. |
||||||||||||
Total Aligned Reads |
The total number of pass-filter reads in the data set that aligned to the reference genome. |
||||||||||||
Unique Aligned Reads |
The number of pass-filter reads that are aligned and are not flagged as duplicates. |
||||||||||||
Total Duplicate Aligned Reads |
The number of pass-filter reads that are aligned and are flagged as duplicates. |
||||||||||||
Percent Duplicate Aligned Reads |
The percentage of paired-end reads that are flagged as duplicates. |
||||||||||||
Total Aligned Read 1 |
The total number of reads passing filter that are aligned for Read 1. |
||||||||||||
Total Aligned Read 2 |
The total number of pass-filter reads that are aligned for Read 2. |
||||||||||||
Percent Aligned Reads |
The percentage of pass-filter reads that are aligned to the reference genome. |
||||||||||||
Percent Unique Aligned Reads |
The percentage of pass-filter reads that are aligned to the reference genome and are not flagged as duplicates. |
||||||||||||
Percent Aligned Read 1 |
The percentage of pass-filter reads that are aligned for Read 1. |
||||||||||||
Percent Aligned Read 2 |
The percentage of pass-filter reads that are aligned for Read 2. |
||||||||||||
Percent Duplicate Proper Read Pairs |
The percentage of duplicate reads that are paired properly, where the reads are aligned inwards [--> < --] within a reasonable distance. |
||||||||||||
Targeted Unique Aligned Bases |
The total aligned bases in the target regions of reads that are not flagged as duplicates. |
||||||||||||
Padded Target Unique Aligned Bases |
The total aligned bases in the padded target regions of reads that are not flagged as duplicates. |
||||||||||||
Unique Base Enrichment |
100* (Targeted unique aligned bases/Unique aligned bases).
|
||||||||||||
Padded Unique Base Enrichment |
100* (Padded target unique aligned bases/Unique aligned bases). |
||||||||||||
Targeted Unique Overlapping Bases |
The number of unique PF bases where the base call corresponds to a fragment position that is in both Read 1 and Read 2 of a paired-end read. |
||||||||||||
Percent Targeted Unique Overlapping Bases |
The percent of unique PF bases where the base call corresponds to a fragment position that is in both Read 1 and Read 2 of a paired-end read. |
||||||||||||
Total PF Bases |
The total number of pass-filter read bases for the sample. |
||||||||||||
Unique PF Bases |
The number of unique pass-filter read bases for the sample |
||||||||||||
Total PF Bases Read 1 |
The number of Read 1 pass-filter read bases for the sample. |
||||||||||||
Total PF Bases Read 2 |
The number of Read 2 pass-filter read bases for the sample. |
||||||||||||
Percent Q30 Bases |
The percentage of bases with a 30 or above quality score. |
||||||||||||
Percent Q30 bases read 1 |
The percentage of Read 1 bases with a 30 or above quality score. |
||||||||||||
Percent Q30 bases read 2 |
The percentage of Read 2 bases with a 30 or above quality score. |
||||||||||||
Total Aligned Bases |
The total aligned bases that includes reads flagged as duplicates. |
||||||||||||
Unique Aligned Bases |
The total aligned bases that includes reads not flagged as duplicates. |
||||||||||||
Total Aligned Bases Read 1 |
The total aligned Read 1 bases that includes reads flagged as duplicates |
||||||||||||
Total Aligned Bases Read 2 |
The total aligned Read 2 bases that includes reads flagged as duplicates. |
||||||||||||
Percent Aligned Bases |
100* (Total aligned bases/Total PF bases) |
||||||||||||
Percent Unique Aligned Bases |
100* (Unique aligned bases / Unique PF bases) |
||||||||||||
Percent Aligned Bases Read 1 |
100* (Total aligned bases Read 1/Total PF bases Read 1) |
||||||||||||
Percent Aligned Bases Read 2 |
100* (Total aligned bases Read 2/Total PF bases Read 2) |
||||||||||||
Percent Mismatches |
The percentage of unique aligned bases where the read base is different than the reference base. |
||||||||||||
Percent Mismatches Read 1 |
The percentage of unique aligned Read 1 bases where the Read 1 base is different than the reference base. |
||||||||||||
Percent Mismatches Read 2 |
The percentage of unique aligned Read 2 bases where the Read 2 base is different than the reference base. |
||||||||||||
Mean Target Coverage Depth |
The total number of targeted bases divided by the targeted region size. |
||||||||||||
Number of Targeted Regions Covered End-to-End |
The number of regions that are covered end-to-end with at least 1X coverage across all non-N reference positions. |
||||||||||||
Percent of Targeted Regions Covered End-to-End |
The percentage of regions that are covered end-to-end with at least 1X coverage across all non-N reference positions. |
||||||||||||
Uniformity of Coverage (Pct > 0.2*mean) |
The percentage of targeted base positions in which the read depth is greater than 0.2 times the mean region target coverage depth. |
||||||||||||
Target Coverage at 1X |
Percentage targets with coverage of at least 1X. |
||||||||||||
Target Coverage at 10X |
Percentage targets with coverage of at least 10X. |
||||||||||||
Target Coverage at 20X |
Percentage targets with coverage of at least 20X. |
||||||||||||
Target Coverage at 50X |
Percentage targets with coverage of at least 50X. |
||||||||||||
Fragment Length Median |
The median length of the sequenced fragment. The fragment length is calculated based on the locations at which a read pair aligns to the reference. The read mapping information is parsed from the BAM files. |
||||||||||||
Fragment Length Min |
Minimum length of the sequenced fragment. |
||||||||||||
Fragment Length Max |
Maximum length of the sequenced fragment. |
||||||||||||
Fragment Length SD |
Standard deviation of the sequenced fragment length. |
||||||||||||
SNVs, Indels, Insertions, Deletions |
Total number of variants present in the data set that pass the quality filters. |
||||||||||||
SNVs, Indels, Insertions, Deletions (All) |
Total number of predicted variants in the data set. |
||||||||||||
SNVs, Indels, Insertions, Deletions (Percent Found in dbSNP) |
100* (Number of variants in dbSNP/Number of variants). |
||||||||||||
SNV Ts/Tv ratio |
The number of Transition SNVs that pass the quality filters divided by the number of Transversion SNVs that pass the quality filters. Transitions are interchanges of purines (A, G) or of pyrimidines (C, T). Transversions are interchanges of purine and pyrimidine bases (for example, A to T). |
||||||||||||
SNVs, Indels, Insertions, Deletions Het/Hom ratio |
Number of heterozygous variants/Number of homozygous variants. |
||||||||||||
SNVs, Insertions, Deletions in Genes |
The number of variants that fall into a gene. |
||||||||||||
SNVs, Insertions, Deletions in Exons |
The number of variants that fall into an exon. |
||||||||||||
SNVs, Insertions, Deletions in Coding Regions |
The number of variants that fall into a coding region. |
||||||||||||
SNVs, Insertions, Deletions in Mature miRNA |
The number of variants that fall into a mature microRNA. |
||||||||||||
SNVs, Insertions, Deletions in UTR Region |
The number of variants that fall into an untranslated region (UTR). |
||||||||||||
SNVs, Insertions, Deletions in Splice Site Region |
The number of variants that fall into a splice site region. |
||||||||||||
Stop Gained SNVs, Insertions, Deletions |
The number of variants that cause an additional stop codon. |
||||||||||||
Stop Lost SNVs, Insertions, Deletions |
The number of variants that cause the loss of a stop codon. |
||||||||||||
Frameshift Insertions, Deletions |
The number of variants that cause a frameshift. |
||||||||||||
Nonsynonymous SNVs, Insertions, Deletions |
The number of variants that cause an amino acid change in a coding region. |
||||||||||||
Synonymous SNVs |
The number of variants that are within a coding region, but do not cause an amino acid change. |
||||||||||||
SV Insertions, Deletions, Tandem Duplications, Inversions, CNVs (All) |
The number of structural variants in the data set. |
||||||||||||
SV Insertions, Deletions, Tandem Duplications, Inversions, CNVs |
The number of structural variants in the data set that pass quality filters. |
||||||||||||
SV Insertions, Deletions, Tandem Duplications, Inversions, CNVs in genes |
The number of structural variants that fall into a gene and pass quality filters. |
||||||||||||
SV Percent Insertions, Deletions, Tandem Duplications, Inversions, CNVs in genes |
The percentage of structural variants that fall into a gene and pass quality filters. |
For Research Use Only. Not for use in diagnostic procedures.