Home/
Automation Overview/Yield/Yield Examples/Example 3: Missing Yield After Lab Requeue

Example 3: Missing Yield After Lab Requeue

In this example, the original request and lab requeue do not produce the required yield before the yield timeout, requiring a second lab requeue.

3a: Yield Requested

A biosample manifest is imported with a prep request required yield of 105 Gbp.

 

Required

Expected

Actual

Pending

3a: Yield Requested

+105

+105

0

+105

Total

105

105

0

105

3b: Partial Yield Received

The lab produces 80 Gbp of QC-passed FASTQ data sets. Actual yield is increased and the amount still pending is changed to 15 GBP to reflect the remaining balance. The expected yield does not change because it represents the total amount expected from the lab and includes actual yield and pending yield.

 

Required

Expected

Actual

Pending

3a: Yield Requested

+105

+105

0

+105

3b: Partial Yield Received

 

 

+80

–80

Total

105

105

80

25

3c: Yield Timeout

Yield timeout is reached with no additional yield received.

NOTE

The default yield timeout is four days, however you can configure a different timeout period using the BaseSpace Sequence Hub API. For more information, see the developer documentation at developer.basespace.illumina.com.

When the yield timeout is reached, BaseSpace Sequence Hub assumes that the lab is unable to produce the requested quantity. The amount pending is classified as missing, and the expected yield is reduced to the actual yield received, indicating that no additional data are expected from the lab.

 

Required

Expected

Actual

Pending

Missing

3a: Yield Requested

+105

+105

0

+105

0

3b: Partial Yield Received

 

 

+80

–80

0

3c: Yield Timeout

 

-25

 

–25

+25

Total

105

80

80

0

25

3d: Lab Requeue for Additional Yield

A lab requeue for more yield is initiated. In this example, the user requested more than the missing amount.

• Expected yield updates. The updated amount reflects the quantity received from the initial request and the additional amount requested from the lab requeue. The required yield does not change because that is the amount of data required for analysis.
• Missing yield is reset to zero.
• Requested yield updates on the Requeues tab.

 

Required

Expected

Actual

Pending

Missing

Requested

3a: Yield Requested

+105

+105

0

+105

0

 

3b: Partial Yield Received

 

 

+80

–80

0

 

3c: Yield Timeout

 

-25

 

–25

+25

 

3d: Lab Requeue for Additional Yield

 

+30

 

+30

–25

+30

Total

105

110

80

30

0

30

3e: Partial Requeue Data Received

The lab produces 20 Gbp of QC-passed FASTQ data sets. Actual yield is increased and the amount still pending is changed to 10 GBP to reflect the remaining balance. The expected yield does not change because it represents the total amount expected from the lab and includes actual yield and pending yield.

 

Required

Expected

Actual

Pending

Missing

Requested

3a: Yield Requested

+105

+105

0

+105

0

 

3b: Partial Yield Received

 

 

+80

–80

0

 

3c: Yield Timeout

 

-25

 

–25

+25

 

3d: Lab Requeue for Additional Yield

 

+30

 

+30

–25

+30

3e: Partial Lab Requeue Data Received

 

 

+20

–20

   

Total

105

110

100

10

0

30

3f: Lab Requeue Expires

The lab requeue expires after the timeout period. As with the yield timeout, the amount pending is classified as missing and the expected yield is reduced to the actual yield received, indicating that no additional data are expected from the lab.

 

Required

Expected

Actual

Pending

Missing

Requested

3a: Yield Requested

+105

+105

0

+105

0

 

3b: Partial Yield Received

 

 

+80

–80

0

 

3c: Yield Timeout

 

-25

 

–25

+25

 

3d: Lab Requeue for Additional Yield

 

+30

 

+30

–25

+30

3e: Partial Lab Requeue Data Received

 

 

+20

–20

 

 

3f: Lab Requeue Expires

 

–10

 

–10

+10

 

Total

105

100

100

0

10

30

3g: New Lab Requeue

Another lab requeue is initiated for 10 Mbp. The new request is listed on the biosample Requeues tab.

 

Required

Expected

Actual

Pending

Missing

Requested

3a: Yield Requested

+105

+105

0

+105

0

 

3b: Partial Yield Received

 

 

+80

–80

0

 

3c: Yield Timeout

 

-25

 

–25

+25

 

3d: Lab Requeue for Additional Yield

 

+30

 

+30

–25

+30

3e: Partial Lab Requeue Data Received

 

 

+20

–20

 

 

3f: Lab Requeue Expires

 

–10

 

–10

+10

 

3g: New Lab Requeue

 

+10

 

+10

–10

+10

Total

105

110

100

10

0

40

3h: Lab Requeue Data Received

The lab produces 5 Mbp of QC-passed FASTQ data. The lab requeue is not completely fulfilled but the required yield dependency is met and analyses can automatically launch if they are not waiting for other dependencies.

 

Required

Expected

Actual

Pending

Missing

Requested

3a: Yield Requested

+105

+105

0

+105

0

 

3b: Partial Yield Received

 

 

+80

–80

0

 

3c: Yield Timeout

 

-25

 

–25

+25

 

3d: Lab Requeue for Additional Yield

 

+30

 

+30

–25

+30

3e: Partial Lab Requeue Data Received

 

 

+20

–20

 

 

3f: Lab Requeue Expires

 

–10

 

–10

+10

 

3g: New Lab Requeue

 

+10

 

+10

–10

+10

3h: Lab Requeue Data Received

 

 

+5

–5

–10

 

Total

105

110

105

5

0

40