Performing a sequencing run requires a single-use HiSeq X Ten Reagent Kit v2.5 or HiSeq X Five Reagent Kit v2.5. Each kit is available in two bundles:
When preparing consumables, check the coded labels:
For other system requirements and compatible products, see HiSeq X Compatibility & Requirements.
The single-pack kit contains the following components. Store at the temperatures indicated in the following tables.
Quantity |
Component |
|
2 | PE Cluster Kit v2 (Box 1 of 2) | |
2 | PE Cluster Kit v2 (Box 2 of 2) | |
2 | Patterned Flow Cell | |
2 | cBot Manifold | |
2 | SBS Kit v2 (Box 1 of 2) | |
2 | SBS Kit v2 (Box 2 of 2) | |
2 | Accessory Kit v2 |
Quantity |
Reagent |
Description |
1 | cBot Reagent Plate | cBot Reagent Plate, PE |
1 | RSB | Resuspension Buffer |
1 | EXP1 | Enhanced Patterned Cluster Mix 1 |
1 | EXP2 | Enhanced Patterned Cluster Mix 2 |
1 | EXP3 | Enhanced Patterned Cluster Mix 3 |
Quantity |
Reagent |
Description |
1 | PRM | Oncology RNA Probes Master Pool |
1 | PLM v2 | Patterned Linearization Mix 2 |
1 | PAM | Patterned Amplification Mix |
1 | PPM | Patterned Amp Premix |
1 | PDR | Patterned Denaturation Mix (contains formamide) |
1 | HP11 | Read 2 Primer Mix |
1 | HP14 | Index i5 and i7 Primer Mix |
Quantity |
Reagent |
Description |
Storage |
1 | PW1 | Wash Buffer | -25°C to 30°C |
1 | PB1* | Patterned SBS Buffer 1 | 15°C to 30°C |
3 | PB2 | Patterned SBS Buffer 2 | 15°C to 30°C |
* PB1 is sensitive to light. Store PB1 in a dark location.
Quantity |
Reagent |
Description |
1 | PCM | Patterned Cleavage Mix |
1 | PIM* | Patterned Incorporation Mix |
1 | PSM | Patterned Scan Mix |
* PIM is sensitive to light. Store PIM in a dark location.
Quantity |
Accessory |
Purpose |
1 | Flow cell gaskets (package of 4) |
Replace the flow cell gaskets between runs |
1 | Flow cell storage tube with storage buffer, 50 ml | Store the flow cell between clustering and sequencing |
1 | Funnel bottle caps (package of 8) |
Replace the caps on SBS reagent bottles before loading reagents |
The 10-pack kit contains the following components. Store at the temperatures indicated in the following tables.
Quantity |
Component |
|
1 | PE Cluster Kit v2 (Box A) | |
1 | PE Cluster Kit v2 (Box B) | |
1 | PE Cluster Kit v2 (Box C) | |
1 | Patterned Flow Cell (Box of 20) | |
20 | cBot Manifold | |
1 | SBS Kit v2 (Box A) | |
2 | SBS Kit v2 (Box B) | |
6 | SBS Kit v2 (Box C) | |
2 | SBS Kit v2 (Box D) | |
2 | SBS Kit v2 (Box E) | |
2 | SBS Kit v2 (Box F) | |
1 | Accessory Kit v2 (Box A) | |
1 | Accessory Kit v2 (Box B) |
Quantity |
Reagent |
Description |
20 | cBot Reagent Plate | cBot reagent plate, PE |
Quantity |
Reagent |
Description |
5 | RSB | Resuspension Buffer |
5 | EPX1M | Enhanced Patterned Cluster Mix 1 |
5 | EPX2M | Enhanced Patterned Cluster Mix 2 |
5 | EPX3M | Enhanced Patterned Cluster Mix 3 |
Enhanced Patterned Cluster Mix 1 |
Enhanced Patterned Cluster Mix 1 |
Quantity |
Reagent |
Description |
20 | PRM | Oncology RNA Probes Master Pool |
20 | PLM v2 | Patterned Linearization Mix 2 |
20 | PAM | Patterned Amplification Mix |
20 | PPM | Patterned Amp Premix |
20 | PDR | Patterned Denaturation Mix (contains formamide) |
20 | HP11 | Read 2 Primer Mix |
20 | HP14 | Index i5 and i7 Primer Mix |
Box |
Reagent |
Quantity |
Description |
Storage |
SBS Box A | PW1 | 20 each | Wash Buffer | -25°C to 30°C |
SBS Box B | PB1* | 10 each | Patterned SBS Buffer 1 | 15°C to 30°C |
SBS Box C | PB2 | 10 each | Patterned SBS Buffer 2 | 15°C to 30°C |
SBS Box D | PCM | 10 each | Patterned Cleavage Mix | -25°C to 30°C |
SBS Box E | PIM* | 10 each | Patterned Incorporation Mix | -25°C to 30°C |
SBS Box F | PSM | 10 each | Patterned Scan Mix | -25°C to 30°C |
* PB1 and PIM are sensitive to light. Store in a dark location.
Box |
Accessory |
Quantity | Purpose |
Box A | Flow cell storage tube with storage buffer, 50 ml | 20 each | Replace the flow cell gaskets between runs. |
Box B | Flow cell gaskets (package of 4) |
20 each | Store the flow cell between clustering and sequencing. |
Box B | Funnel bottle caps (package of 8) |
20 each | Replace the caps on SBS reagent bottles before loading reagents. |