Performing a run requires one TruSeq Cluster Kit v3 and one TruSeq SBS Kit v3.
For other system requirements, dual indexing considerations, and compatible products, see HiSeq 1000 Requirements & Compatibility.
When you receive your kits, promptly store kit components at the indicated temperatures to ensure proper performance.
TruSeq Cluster Kit v3 reagents are shipped in four boxes on dry ice. A flow cell, manifold, and accessories are also included.
Quantity |
Reagent |
Description |
1 |
HP3 |
Denaturation Solution |
1 |
HT2 |
Wash Buffer |
1 |
RMR |
Resynthesis Mix |
1 |
AT2 |
100% Formamide |
1 |
APM2 |
Amplification Premix |
1 |
AMX2 |
Amplification Mix 2 |
1 |
LMX2 |
Linearization Mix 2 |
1 |
BMX |
Blocking Mix |
1 |
HP7* |
Read 2 Sequencing Primer Mix |
* Instead of HP7, Nextera libraries require HP11 provided in the TruSeq Dual Index Sequencing Primer Box.
Quantity |
Kit Component |
Description |
1 |
cBot Reagent Plate |
cBot PE reagent plate |
1 |
HT1 |
Hybridization Buffer |
Quantity |
Reagent |
Description |
1 |
cBot Reagent Plate |
cBot SR reagent plate |
1 |
HT1 |
Hybridization Buffer |
Quantity |
Reagent |
Description |
1 |
HP3 |
Denaturation Solution |
1 |
HT2 |
Wash Buffer |
1 |
HP8* |
Index Sequencing Primer |
* Instead of HP8, Nextera libraries require HP12 provided in the TruSeq Dual Index Sequencing Primer Box.
Quantity |
Component |
Purpose |
4 |
Flow cell gaskets |
Replace the flow cell gaskets between runs. |
8 |
Funnel bottle caps |
Replace SBS reagent bottle caps before loading reagents. |
1 |
ICB instrument tube |
Divide ICB for Read 2. |
TruSeq SBS Kit v3 reagents are shipped in two boxes on dry ice.
Reagents are labeled with a three-letter acronym plus a numeric designator that indicates the kit size. For example, if you are using CMR-50, the CMR was provided in a 50-cycle kit.
Quantity |
Reagent |
Description |
Storage Temperature |
1 |
PW1 |
Wash Buffer |
-25°C to 30°C |
1 |
ICB |
Incorporation Mix Buffer |
2°C to 8°C |
1 |
SB1 |
High Salt Buffer |
2°C to 8°C |
2 |
SB2 |
Incorporation Wash Buffer |
2°C to 8°C |
1 |
SB3 |
Cleavage Buffer |
2°C to 8°C |
Quantity |
Reagent |
Description |
1 |
CMR |
Cleavage Mix Reagent |
1 |
SRE |
Enhanced Scan Mix Reagent |
1 |
EDP |
Enhanced DNA Polymerase |
4—200-cycle kit 1—50-cycle kit |
LFN36 |
Long Read Nucleotide Mix |
Reagent Name |
Storage |
Description |
HP9 |
-25° to -15°C |
Index 2 (i5) Sequencing Primer Mix |
HP10 |
-25° to -15°C |
Read 1 Sequencing Primer Mix |
HP12 |
-25° to -15°C |
Index 1 (i7) Sequencing Primer Mix |
Reagent Name |
Storage |
Description |
HP10 |
-25° to -15°C |
Read 1 Sequencing Primer Mix |
HP11 |
-25° to -15°C |
Read 2 Sequencing Primer Mix |
HP12 |
-25° to -15°C |
Index 1 (i7) Sequencing Primer Mix |