The following table details the compatibility relationship between operating system, control software version, and sequencing chemistry type.
| Operating System | Control Software Version | Sequencing Chemistry | 
|---|---|---|
| Oracle Linux 9 | 2.0 and higher | XLEAP-SBS chemistry | 
| CentOS 7 | 1.7 and lower | XLEAP-SBS chemistry and Standard SBS chemistry | 
Choose from the following options to record information about your samples, such as sample ID and which index adapters are used for pooling.
Use Sequencing Analysis Viewer or BaseSpace Sequence Hub to monitor real-time quality metrics during a run.
To analyze sequencing data, choose from the following options:
The NextSeq 1000/2000 Sequencing System performs secondary analysis using the on-intsrument DRAGEN BIO-IT Platform. See the NextSeq 1000/2000 Sequencing System Guide for more information.
The DRAGEN Single Cell RNA analysis pipeline provides compatibility with third-party kits. For more information on third-party kit compatibility, see Single Cell RNA Product Compatibility.
The following DRAGEN workflow versions are compatible with the NextSeq 1000/2000 Control Software versions.
| Control Software Version | ||||
|---|---|---|---|---|
| DRAGEN Version | 1.2 - 1.5 | 1.7 | 2.0 | |
| 4.2.11 | Not available | Not available | 
 | |
| 4.2.9 | Not available | 
 | Not available | |
| 4.2.7 | Not available | 
 | Not available | |
| 3.10.12 | 
 | Not available | Not available | |
| 3.9.3 | 
 | Not available | Not available | |
| 3.8.4 | 
 | Not available | Not available | |
| 3.7.4 | 
 | Not available | Not available | |
| 3.5.8 | Not available | Not available | Not available | |
| 3.5.6 | Not available | Not available | Not available | |
| Genome Name | Display Name | Species | GTF Available | DRAGEN Versions | 
|---|---|---|---|---|
| hg19_alt_aware | Human UCSC hg19 Custom Alt Aware | Homo sapiens [Human] | Yes | 3.5, 3.7, 3.8, 3.10 | 
| hg19_no_alt_haps_no_decoys | Human UCSC hg19 Custom Alt Aware No Alt Haps No Decoys | Homo sapiens [Human] | Yes | 3.5, 3.7, 3.8, 3.10 | 
| hg19_alt_aware_graph_based | Human UCSC hg19 Custom Alt Aware Graph | Homo sapiens [Human] | Yes | 3.8, 3.10 | 
| hg19-alt-masked_v3 | Homo sapiens [UCSC] hg19 Alt Masked v3 | Homo sapiens [Human] | Yes | 4.2 | 
| hg19-alt-masked.graph_v3 | Homo sapiens [UCSC] hg19 Alt Masked v3 Graph | Homo sapiens [Human] | Yes | 4.2 | 
| hs37d5 | Human NCBI hs37d5 | Homo sapiens [Human] | Yes | 3.5, 3.7, 3.8, 3.10 | 
| hs37d5_graph_based | Human NCBI hs37d5 Graph | Homo sapiens [Human] | Yes | 3.8, 3.10 | 
| hs37d5_v3 | Homo sapiens [NCBI] hs37d5 v3 | Homo sapiens [Human] | Yes | 4.2 | 
| hs37d5.graph_v3 | Homo sapiens [NCBI] hs37d5 v3 Graph | Homo sapiens [Human] | Yes | 4.2 | 
| hg38_alt_aware | Human 1000 Genomes hg38 Alt Aware | Homo sapiens [Human] | Yes | 3.5, 3.7, 3.8, 3.10 | 
| hg38-noalt-with-decoy | Human 1000 Genomes hg38 Noalt with Decoys | Homo sapiens [Human] | Yes | 3.5, 3.7, 3.8, 3.10 | 
| hg38_alt_aware_graph_based | Human 1000 Genomes hg38 Alt Aware | Homo sapiens [Human] | Yes | 3.8, 3.10 | 
| hg38-alt-masked_v3 | Homo sapiens [1000 Genomes] hg38 Alt Masked v3 | Homo sapiens [Human] | Yes | 4.2 | 
| hg38-alt-masked.graph_v3 | Homo sapiens [1000 Genomes] hg38 Alt Masked v3 Graph | Homo sapiens [Human] | Yes | 4.2 | 
| mm10 | Mus musculus [UCSC] mm10 | Mus Musculus [House Mouse] | Yes | 3.5, 3.7, 3.8, 3.10, 4.2 | 
| phix | Microvirus Escherichia virus phiX174 [NCBI] | PhiX | No | 3.5, 3.7, 3.8, 3.10, 4.2 | 
| rn6 | Rattus norvegicus [UCSC] rn6 | Rattus Norvegicus [Norway Rat] | Yes | 3.5, 3.7, 3.8, 3.10, 4.2 | 
| Rhodobacter_sphaeroides_2.4.1 | R.sphaeroides [NCBI] 2.4.1 | Rhodobacter Sphaeroides [Bacterium] | No | 3.5, 3.7, 3.8, 3.10, 4.2 | 
| Bacillus_cereus_ATCC_10987 | B. cereus [NCBI] ATCC_10987 | Bacillus Cereus [Bacterium] | No | 3.5, 3.7, 3.8, 3.10, 4.2 | 
| WBcel235 | C. elegans [Ensembl] WBcel235 | Caenorhabditis Elegans [Roundworm] | No | 3.5, 3.7, 3.8, 3.10, 4.2 | 
| A_Thaliana | A. thaliana [TAIR] TAIR10 | Arabidopsis Thaliana | No | 3.5, 3.7, 3.8, 3.10, 4.2 | 
| eschColi_K12_1 | E. coli [NCBI] K12 MG1655 | Escherichia Coli [Strain K12] | No | 3.5, 3.7, 3.8, 3.10, 4.2 | 
If using DRAGEN BIO-IT Platform for secondary analysis, the following are the recommended reference genomes for each DRAGEN pipeline.